SLAC Magnetic Measurements Date: 10-03-2022 Time: 12:13:23 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 73 Measurement Type: Long Coil Scans Operator: YL Comment: Check background Center position: X0=0.002000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -4.963E-06 -70.887E-06 75.00000 75.00035 0 75.00035 0 75.00035 0 75.00030 0 1 -4.975E-06 -71.056E-06 75.00000 75.00030 0 75.00035 0 75.00030 0 75.00035 0 2 -5.009E-06 -71.546E-06 75.00000 75.00035 0 75.00030 0 75.00030 0 75.00035 0 3 -5.072E-06 -72.448E-06 75.00000 75.00035 0 75.00030 0 75.00030 0 75.00035 0 4 -5.088E-06 -72.676E-06 75.00000 75.00030 0 75.00035 0 75.00030 0 75.00030 0