SLAC Magnetic Measurements Date: 10-03-2022 Time: 12:08:58 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 73 Measurement Type: Long Coil Scans Operator: YL Comment: Check background Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -5.759E-06 -82.254E-06 75.00000 75.00030 0 75.00020 0 75.00030 0 75.00020 0 1 -6.051E-06 -86.419E-06 75.00000 75.00030 0 75.00025 0 75.00025 0 75.00025 0 2 -6.038E-06 -86.243E-06 75.00000 75.00025 0 75.00030 0 75.00030 0 75.00030 0 3 -6.077E-06 -86.796E-06 75.00000 75.00030 0 75.00030 0 75.00030 0 75.00025 0 4 -5.810E-06 -82.981E-06 75.00000 75.00030 0 75.00025 0 75.00030 0 75.00025 0