SLAC Magnetic Measurements Date: 09-30-2022 Time: 10:39:00 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 69 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Bx field Center position: X0=0.000000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -5.521E-06 -78.858E-06 75.00000 75.00015 0 75.00010 0 75.00010 0 75.00010 0 1 -5.485E-06 -78.335E-06 75.00000 75.00020 0 75.00005 0 75.00010 0 75.00010 0 2 -5.667E-06 -80.936E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00010 0 3 -5.634E-06 -80.463E-06 75.00000 75.00010 0 75.00015 0 75.00010 0 75.00015 0 4 -5.841E-06 -83.422E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00015 0