SLAC Magnetic Measurements Date: 09-30-2022 Time: 09:37:50 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 69 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Bx field Center position: X0=0.000000, Y0=0.000000 Nominal Gap=7.20 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -3.115E-06 -44.488E-06 7.20000 7.20005 0 7.20000 0 7.20005 0 7.19995 0 1 -3.005E-06 -42.921E-06 7.20000 7.20005 0 7.20000 0 7.20000 0 7.20005 0 2 -3.147E-06 -44.942E-06 7.20000 7.20005 0 7.19995 0 7.20005 0 7.20000 0 3 -3.294E-06 -47.045E-06 7.20000 7.20005 0 7.20000 0 7.20005 0 7.20000 0 4 -2.584E-06 -36.909E-06 7.20000 7.20005 0 7.20000 0 7.20005 0 7.20000 0