SLAC Magnetic Measurements Date: 09-30-2022 Time: 21:07:02 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 72 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Normal quad Center position: X0=0.002000, Y0=0.000000 Nominal Gap=100.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -5.148E-06 -73.532E-06 100.00000 100.00030 0 100.00025 0 100.00030 0 100.00025 0 1 -5.034E-06 -71.904E-06 100.00000 100.00030 0 100.00025 0 100.00030 0 100.00025 0 2 -5.045E-06 -72.057E-06 100.00000 100.00030 0 100.00025 0 100.00030 0 100.00025 0 3 -5.108E-06 -72.950E-06 100.00000 100.00030 0 100.00025 0 100.00035 0 100.00025 0 4 -5.098E-06 -72.811E-06 100.00000 100.00035 0 100.00030 0 100.00030 0 100.00025 0