SLAC Magnetic Measurements Date: 09-30-2022 Time: 20:46:31 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 72 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Normal quad Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -6.127E-06 -87.513E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00020 0 1 -6.113E-06 -87.312E-06 75.00000 75.00020 0 75.00020 0 75.00020 0 75.00015 0 2 -6.152E-06 -87.862E-06 75.00000 75.00015 0 75.00015 0 75.00020 0 75.00015 0 3 -6.093E-06 -87.024E-06 75.00000 75.00015 0 75.00020 0 75.00020 0 75.00015 0 4 -6.089E-06 -86.970E-06 75.00000 75.00015 0 75.00015 0 75.00020 0 75.00015 0