SLAC Magnetic Measurements Date: 09-30-2022 Time: 20:34:45 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 72 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Normal quad Center position: X0=0.002000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -3.439E-06 -49.122E-06 50.00000 50.00025 0 50.00010 0 50.00025 0 50.00010 0 1 -3.310E-06 -47.283E-06 50.00000 50.00025 0 50.00010 0 50.00025 0 50.00010 0 2 -3.362E-06 -48.024E-06 50.00000 50.00025 0 50.00010 0 50.00025 0 50.00010 0 3 -3.278E-06 -46.817E-06 50.00000 50.00025 0 50.00010 0 50.00025 0 50.00010 0 4 -3.146E-06 -44.939E-06 50.00000 50.00025 0 50.00010 0 50.00025 0 50.00010 0