SLAC Magnetic Measurements Date: 09-30-2022 Time: 20:14:32 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 72 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Normal quad Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=33.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -1.950E-06 -27.854E-06 33.00000 33.00040 0 33.00015 0 33.00040 0 33.00015 0 1 -1.819E-06 -25.977E-06 33.00000 33.00040 0 33.00015 0 33.00040 0 33.00015 0 2 -1.901E-06 -27.149E-06 33.00000 33.00040 0 33.00015 0 33.00040 0 33.00015 0 3 -1.936E-06 -27.650E-06 33.00000 33.00040 0 33.00015 0 33.00040 0 33.00015 0 4 -2.050E-06 -29.282E-06 33.00000 33.00040 0 33.00015 0 33.00045 0 33.00015 0