SLAC Magnetic Measurements Date: 09-26-2022 Time: 16:22:57 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 60 Measurement Type: Long Coil Scans Operator: YL Comment: Background for shim signatures; PDI Center position: X0=0.000000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -4.949E-06 -70.679E-06 50.00000 50.00015 0 50.00010 0 50.00015 0 50.00015 0 1 -4.948E-06 -70.665E-06 50.00000 50.00015 0 50.00010 0 50.00015 0 50.00010 0 2 -4.787E-06 -68.367E-06 50.00000 50.00020 0 50.00010 0 50.00015 0 50.00015 0 3 -4.769E-06 -68.122E-06 50.00000 50.00015 0 50.00015 0 50.00020 0 50.00015 0 4 -4.832E-06 -69.020E-06 50.00000 50.00020 0 50.00015 0 50.00020 0 50.00015 0