SLAC Magnetic Measurements Date: 09-26-2022 Time: 15:58:32 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 60 Measurement Type: Long Coil Scans Operator: YL Comment: Background for shim signatures; PDI Center position: X0=0.000000, Y0=0.000000 Nominal Gap=15.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.885E-06 26.930E-06 15.00000 15.00025 0 15.00005 0 15.00035 0 15.00010 0 1 1.798E-06 25.684E-06 15.00000 15.00060 0 15.00010 0 15.00060 0 15.00010 0 2 1.713E-06 24.464E-06 15.00000 15.00075 0 15.00010 0 15.00075 0 15.00010 0 3 1.802E-06 25.736E-06 15.00000 15.00080 0 15.00015 0 15.00085 0 15.00015 0 4 1.898E-06 27.106E-06 15.00000 15.00090 0 15.00015 0 15.00085 0 15.00015 0