Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 18 333.1178 262.7557 -0.2582 -2.5157 -15.5906 17 333.1142 262.7474 -0.2670 -2.7206 -15.6403 Mean 333.1160 262.7516 -0.2626 -2.6181 -15.6154 Std 0.0025 0.0058 0.0062 0.1448 0.0351 Error 0.00241 0.00338 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 18 58.4950 -2.8070 0.1221 64.1455 61.2716 0.0071 17 54.5949 -10.5070 -8.6779 60.8455 57.6671 -8.2312 Mean 56.5449 -6.6570 -4.2779 62.4955 59.4693 -4.1120 Std 2.7578 5.4447 6.2225 2.3334 2.5488 5.8253