Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 7 333.1103 262.7509 0.1713 -2.4196 -12.7142 8 333.1164 262.7618 0.1721 -2.3914 -13.1537 Mean 333.1134 262.7563 0.1717 -2.4055 -12.9339 Std 0.0043 0.0077 0.0006 0.0199 0.3108 Error 0.00261 0.00355 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 7 49.3948 -7.6069 -4.6779 58.3454 53.7937 -4.7925 8 54.7949 2.1930 7.4221 65.0454 59.8312 6.1327 Mean 52.0949 -2.7069 1.3721 61.6954 56.8125 0.6701 Std 3.8185 6.9296 8.5560 4.7376 4.2691 7.7253