SLAC Magnetic Measurements Date: 08-12-2026 Time: 16:54:39 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: PS_DELTA-II Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 7 Measurement Device: Stretched Wire Operator: YL Comment: 16:54:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:49 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:54:50 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:54:52 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:54:53 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:55:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:14 Integrated Voltage Measurement... 16:55:23 Voltage Offset Correction: v_off_ini = 2152.524 uV, v_off_fin = 2163.458 uV 16:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 331.474 uVs 16:55:23 Integrated Voltage Measurement... 16:55:32 Voltage Offset Correction: v_off_ini = 2164.030 uV, v_off_fin = 2161.670 uV 16:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -346.131 uVs 16:55:32 Integrated Voltage Measurement... 16:55:41 Voltage Offset Correction: v_off_ini = 2129.564 uV, v_off_fin = 2143.239 uV 16:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 342.036 uVs 16:55:41 Integrated Voltage Measurement... 16:55:50 Voltage Offset Correction: v_off_ini = 2146.549 uV, v_off_fin = 2144.487 uV 16:55:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -337.222 uVs 16:55:50 Integrated Voltage Measurement... 16:55:59 Voltage Offset Correction: v_off_ini = 2141.534 uV, v_off_fin = 2132.090 uV 16:55:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 331.924 uVs 16:55:59 Integrated Voltage Measurement... 16:56:08 Voltage Offset Correction: v_off_ini = 2118.456 uV, v_off_fin = 2143.926 uV 16:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -326.226 uVs 16:56:12 I1X Average and RMS of Measurements VT = 335.836 +- 4.792 uVs I1X = -67.167 +- 0.958 uTm 16:56:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:19 Integrated Voltage Measurement... 16:56:28 Voltage Offset Correction: v_off_ini = 2149.985 uV, v_off_fin = 2120.786 uV 16:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.116 uVs 16:56:28 Integrated Voltage Measurement... 16:56:37 Voltage Offset Correction: v_off_ini = 2126.853 uV, v_off_fin = 2136.409 uV 16:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.522 uVs 16:56:37 Integrated Voltage Measurement... 16:56:46 Voltage Offset Correction: v_off_ini = 2128.926 uV, v_off_fin = 2134.208 uV 16:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.033 uVs 16:56:46 Integrated Voltage Measurement... 16:56:55 Voltage Offset Correction: v_off_ini = 2154.104 uV, v_off_fin = 2157.687 uV 16:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.131 uVs 16:56:55 Integrated Voltage Measurement... 16:57:04 Voltage Offset Correction: v_off_ini = 2143.449 uV, v_off_fin = 2136.072 uV 16:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.132 uVs 16:57:04 Integrated Voltage Measurement... 16:57:13 Voltage Offset Correction: v_off_ini = 2151.058 uV, v_off_fin = 2162.394 uV 16:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.196 uVs 16:57:17 I1Y Average and RMS of Measurements VT = -193.688 +- 1.776 uVs I1Y = -38.735 +- 0.357 uTm 16:57:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:25 Integrated Voltage Measurement... 16:57:34 Voltage Offset Correction: v_off_ini = 2156.356 uV, v_off_fin = 2162.814 uV 16:57:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 318.441 uVs 16:57:34 Integrated Voltage Measurement... 16:57:43 Voltage Offset Correction: v_off_ini = 2149.235 uV, v_off_fin = 2163.044 uV 16:57:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.218 uVs 16:57:43 Integrated Voltage Measurement... 16:57:52 Voltage Offset Correction: v_off_ini = 2140.419 uV, v_off_fin = 2145.988 uV 16:57:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.980 uVs 16:57:52 Integrated Voltage Measurement... 16:58:01 Voltage Offset Correction: v_off_ini = 2132.094 uV, v_off_fin = 2135.258 uV 16:58:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.168 uVs 16:58:01 Integrated Voltage Measurement... 16:58:10 Voltage Offset Correction: v_off_ini = 2136.996 uV, v_off_fin = 2136.434 uV 16:58:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.062 uVs 16:58:10 Integrated Voltage Measurement... 16:58:19 Voltage Offset Correction: v_off_ini = 2145.158 uV, v_off_fin = 2161.548 uV 16:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.041 uVs 16:58:21 I2X Average and RMS of Measurements VT = 344.485 +- 10.495 uVs I2X = -31.692 +- 0.966 uTm^2 16:58:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:29 Integrated Voltage Measurement... 16:58:38 Voltage Offset Correction: v_off_ini = 2164.429 uV, v_off_fin = 2179.374 uV 16:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.281 uVs 16:58:38 Integrated Voltage Measurement... 16:58:47 Voltage Offset Correction: v_off_ini = 2183.484 uV, v_off_fin = 2172.149 uV 16:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.384 uVs 16:58:47 Integrated Voltage Measurement... 16:58:56 Voltage Offset Correction: v_off_ini = 2160.981 uV, v_off_fin = 2159.814 uV 16:58:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.582 uVs 16:58:56 Integrated Voltage Measurement... 16:59:05 Voltage Offset Correction: v_off_ini = 2150.850 uV, v_off_fin = 2136.842 uV 16:59:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.413 uVs 16:59:05 Integrated Voltage Measurement... 16:59:14 Voltage Offset Correction: v_off_ini = 2152.244 uV, v_off_fin = 2146.892 uV 16:59:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.218 uVs 16:59:14 Integrated Voltage Measurement... 16:59:23 Voltage Offset Correction: v_off_ini = 2166.777 uV, v_off_fin = 2166.163 uV 16:59:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.252 uVs 16:59:26 I2Y Average and RMS of Measurements VT = -243.855 +- 12.566 uVs I2Y = -22.435 +- 1.156 uTm^2 16:59:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm