SLAC Magnetic Measurements Date: 08-12-2026 Time: 16:18:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: PS_DELTA-II Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 4 Measurement Device: Stretched Wire Operator: YL Comment: Parameters: Measurement Type = I12XY VS X VS GAP I1X dy = 0.5000 mm I1Y dx = 0.5000 mm I2X dy = 1.0000 mm I2Y dx = 1.0000 mm Wire # Turns = 1 Preamplifier Gain = 10000.00 Background Field Integrals: I1X = 22.0 (uTm) I1Y = -44.0 (uTm) I2X = 11.0 (uTm2) I2Y = -22.0 (uTm2) Subtracted from results Field Integrals: Gap (mm) X0 (mm) Y0 (mm) I1x (uTm) I1y (uTm) I2x (uTm^2) I2y (uTm^2) ---------- ---------- ---------- ---------------------- ---------------------- ---------------------- ---------------------- 9.999 0.000 0.000 23.949+- 1.062 4.393+- 2.041 10.280+- 1.238 -0.073+- 0.343