SLAC Magnetic Measurements Date: 08-11-2026 Time: 14:48:23 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: PS_DELTA-II Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 14:48:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:33 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:48:34 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:48:36 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:48:37 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:49:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:33 Integrated Voltage Measurement... 14:49:42 Voltage Offset Correction: v_off_ini = 3137.083 uV, v_off_fin = 3112.559 uV 14:49:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -155.422 uVs 14:49:42 Integrated Voltage Measurement... 14:49:51 Voltage Offset Correction: v_off_ini = 3093.835 uV, v_off_fin = 3073.638 uV 14:49:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.598 uVs 14:49:51 Integrated Voltage Measurement... 14:50:00 Voltage Offset Correction: v_off_ini = 3082.988 uV, v_off_fin = 3056.407 uV 14:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.157 uVs 14:50:00 Integrated Voltage Measurement... 14:50:09 Voltage Offset Correction: v_off_ini = 3057.055 uV, v_off_fin = 3054.719 uV 14:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.261 uVs 14:50:09 Integrated Voltage Measurement... 14:50:18 Voltage Offset Correction: v_off_ini = 3037.829 uV, v_off_fin = 3017.973 uV 14:50:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.118 uVs 14:50:18 Integrated Voltage Measurement... 14:50:27 Voltage Offset Correction: v_off_ini = 3010.716 uV, v_off_fin = 3003.877 uV 14:50:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.736 uVs 14:50:31 I1X Average and RMS of Measurements VT = -138.715 +- 6.985 uVs I1X = 27.745 +- 1.399 uTm 14:50:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:38 Integrated Voltage Measurement... 14:50:47 Voltage Offset Correction: v_off_ini = 2940.444 uV, v_off_fin = 2934.351 uV 14:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.781 uVs 14:50:47 Integrated Voltage Measurement... 14:50:56 Voltage Offset Correction: v_off_ini = 2932.269 uV, v_off_fin = 2923.611 uV 14:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.386 uVs 14:50:56 Integrated Voltage Measurement... 14:51:05 Voltage Offset Correction: v_off_ini = 2923.067 uV, v_off_fin = 2911.304 uV 14:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.451 uVs 14:51:05 Integrated Voltage Measurement... 14:51:14 Voltage Offset Correction: v_off_ini = 2906.291 uV, v_off_fin = 2911.483 uV 14:51:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.023 uVs 14:51:14 Integrated Voltage Measurement... 14:51:23 Voltage Offset Correction: v_off_ini = 2883.387 uV, v_off_fin = 2872.556 uV 14:51:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.594 uVs 14:51:23 Integrated Voltage Measurement... 14:51:32 Voltage Offset Correction: v_off_ini = 2872.060 uV, v_off_fin = 2877.683 uV 14:51:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.950 uVs 14:51:36 I1Y Average and RMS of Measurements VT = -190.864 +- 2.435 uVs I1Y = -38.173 +- 0.487 uTm 14:51:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:44 Integrated Voltage Measurement... 14:51:53 Voltage Offset Correction: v_off_ini = 2822.344 uV, v_off_fin = 2818.862 uV 14:51:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.967 uVs 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 2816.701 uV, v_off_fin = 2838.449 uV 14:52:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 167.824 uVs 14:52:02 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 2835.672 uV, v_off_fin = 2812.345 uV 14:52:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -176.616 uVs 14:52:11 Integrated Voltage Measurement... 14:52:20 Voltage Offset Correction: v_off_ini = 2801.108 uV, v_off_fin = 2811.620 uV 14:52:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.531 uVs 14:52:20 Integrated Voltage Measurement... 14:52:29 Voltage Offset Correction: v_off_ini = 2801.289 uV, v_off_fin = 2781.264 uV 14:52:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.401 uVs 14:52:29 Integrated Voltage Measurement... 14:52:38 Voltage Offset Correction: v_off_ini = 2778.268 uV, v_off_fin = 2788.863 uV 14:52:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.627 uVs 14:52:40 I2X Average and RMS of Measurements VT = -155.828 +- 2.898 uVs I2X = 14.336 +- 0.267 uTm^2 14:52:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:48 Integrated Voltage Measurement... 14:52:57 Voltage Offset Correction: v_off_ini = 2770.591 uV, v_off_fin = 2744.458 uV 14:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.631 uVs 14:52:57 Integrated Voltage Measurement... 14:53:06 Voltage Offset Correction: v_off_ini = 2752.548 uV, v_off_fin = 2770.477 uV 14:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.277 uVs 14:53:06 Integrated Voltage Measurement... 14:53:15 Voltage Offset Correction: v_off_ini = 2749.224 uV, v_off_fin = 2733.300 uV 14:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.189 uVs 14:53:15 Integrated Voltage Measurement... 14:53:24 Voltage Offset Correction: v_off_ini = 2720.551 uV, v_off_fin = 2726.695 uV 14:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.209 uVs 14:53:24 Integrated Voltage Measurement... 14:53:33 Voltage Offset Correction: v_off_ini = 2702.014 uV, v_off_fin = 2694.056 uV 14:53:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.325 uVs 14:53:33 Integrated Voltage Measurement... 14:53:42 Voltage Offset Correction: v_off_ini = 2685.683 uV, v_off_fin = 2665.658 uV 14:53:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.177 uVs 14:53:44 I2Y Average and RMS of Measurements VT = -239.968 +- 5.550 uVs I2Y = -22.077 +- 0.511 uTm^2 14:53:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:59 Integrated Voltage Measurement... 14:54:08 Voltage Offset Correction: v_off_ini = 2637.261 uV, v_off_fin = 2625.278 uV 14:54:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.803 uVs 14:54:08 Integrated Voltage Measurement... 14:54:17 Voltage Offset Correction: v_off_ini = 2629.244 uV, v_off_fin = 2625.420 uV 14:54:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.765 uVs 14:54:17 Integrated Voltage Measurement... 14:54:26 Voltage Offset Correction: v_off_ini = 2577.388 uV, v_off_fin = 2588.311 uV 14:54:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.346 uVs 14:54:26 Integrated Voltage Measurement... 14:54:35 Voltage Offset Correction: v_off_ini = 2571.250 uV, v_off_fin = 2584.562 uV 14:54:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.372 uVs 14:54:35 Integrated Voltage Measurement... 14:54:44 Voltage Offset Correction: v_off_ini = 2588.637 uV, v_off_fin = 2573.674 uV 14:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.377 uVs 14:54:44 Integrated Voltage Measurement... 14:54:53 Voltage Offset Correction: v_off_ini = 2583.498 uV, v_off_fin = 2575.842 uV 14:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.494 uVs 14:54:57 I1X Average and RMS of Measurements VT = -150.026 +- 7.116 uVs I1X = 30.005 +- 1.423 uTm 14:55:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:04 Integrated Voltage Measurement... 14:55:13 Voltage Offset Correction: v_off_ini = 2557.505 uV, v_off_fin = 2547.389 uV 14:55:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -209.512 uVs 14:55:13 Integrated Voltage Measurement... 14:55:22 Voltage Offset Correction: v_off_ini = 2521.864 uV, v_off_fin = 2553.264 uV 14:55:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.888 uVs 14:55:22 Integrated Voltage Measurement... 14:55:31 Voltage Offset Correction: v_off_ini = 2537.469 uV, v_off_fin = 2532.530 uV 14:55:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.401 uVs 14:55:31 Integrated Voltage Measurement... 14:55:40 Voltage Offset Correction: v_off_ini = 2537.473 uV, v_off_fin = 2545.857 uV 14:55:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.786 uVs 14:55:40 Integrated Voltage Measurement... 14:55:49 Voltage Offset Correction: v_off_ini = 2504.100 uV, v_off_fin = 2530.426 uV 14:55:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.515 uVs 14:55:49 Integrated Voltage Measurement... 14:55:58 Voltage Offset Correction: v_off_ini = 2540.059 uV, v_off_fin = 2523.894 uV 14:55:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.738 uVs 14:56:02 I1Y Average and RMS of Measurements VT = -192.473 +- 13.913 uVs I1Y = -38.496 +- 2.784 uTm 14:56:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:10 Integrated Voltage Measurement... 14:56:19 Voltage Offset Correction: v_off_ini = 2486.478 uV, v_off_fin = 2483.461 uV 14:56:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.572 uVs 14:56:19 Integrated Voltage Measurement... 14:56:28 Voltage Offset Correction: v_off_ini = 2475.210 uV, v_off_fin = 2485.872 uV 14:56:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.466 uVs 14:56:28 Integrated Voltage Measurement... 14:56:37 Voltage Offset Correction: v_off_ini = 2472.549 uV, v_off_fin = 2464.733 uV 14:56:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -173.186 uVs 14:56:37 Integrated Voltage Measurement... 14:56:46 Voltage Offset Correction: v_off_ini = 2465.005 uV, v_off_fin = 2472.392 uV 14:56:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 169.346 uVs 14:56:46 Integrated Voltage Measurement... 14:56:55 Voltage Offset Correction: v_off_ini = 2476.699 uV, v_off_fin = 2472.568 uV 14:56:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -173.570 uVs 14:56:55 Integrated Voltage Measurement... 14:57:04 Voltage Offset Correction: v_off_ini = 2489.494 uV, v_off_fin = 2494.838 uV 14:57:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.890 uVs 14:57:06 I2X Average and RMS of Measurements VT = -167.338 +- 3.901 uVs I2X = 15.395 +- 0.359 uTm^2 14:57:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:14 Integrated Voltage Measurement... 14:57:23 Voltage Offset Correction: v_off_ini = 2465.596 uV, v_off_fin = 2467.669 uV 14:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.321 uVs 14:57:23 Integrated Voltage Measurement... 14:57:32 Voltage Offset Correction: v_off_ini = 2457.605 uV, v_off_fin = 2457.852 uV 14:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.970 uVs 14:57:32 Integrated Voltage Measurement... 14:57:41 Voltage Offset Correction: v_off_ini = 2446.127 uV, v_off_fin = 2457.677 uV 14:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.510 uVs 14:57:41 Integrated Voltage Measurement... 14:57:50 Voltage Offset Correction: v_off_ini = 2456.113 uV, v_off_fin = 2441.873 uV 14:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.147 uVs 14:57:50 Integrated Voltage Measurement... 14:57:59 Voltage Offset Correction: v_off_ini = 2440.325 uV, v_off_fin = 2438.073 uV 14:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.829 uVs 14:57:59 Integrated Voltage Measurement... 14:58:08 Voltage Offset Correction: v_off_ini = 2416.947 uV, v_off_fin = 2418.794 uV 14:58:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.606 uVs 14:58:11 I2Y Average and RMS of Measurements VT = -254.897 +- 11.351 uVs I2Y = -23.451 +- 1.044 uTm^2 14:58:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:26 Integrated Voltage Measurement... 14:58:35 Voltage Offset Correction: v_off_ini = 2397.476 uV, v_off_fin = 2389.330 uV 14:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -171.863 uVs 14:58:35 Integrated Voltage Measurement... 14:58:44 Voltage Offset Correction: v_off_ini = 2386.281 uV, v_off_fin = 2384.987 uV 14:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.255 uVs 14:58:44 Integrated Voltage Measurement... 14:58:53 Voltage Offset Correction: v_off_ini = 2376.238 uV, v_off_fin = 2353.863 uV 14:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.713 uVs 14:58:53 Integrated Voltage Measurement... 14:59:02 Voltage Offset Correction: v_off_ini = 2356.484 uV, v_off_fin = 2375.369 uV 14:59:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.004 uVs 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 2366.104 uV, v_off_fin = 2362.790 uV 14:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -163.581 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 2348.671 uV, v_off_fin = 2374.722 uV 14:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.751 uVs 14:59:24 I1X Average and RMS of Measurements VT = -172.195 +- 3.200 uVs I1X = 34.440 +- 0.639 uTm 14:59:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:31 Integrated Voltage Measurement... 14:59:39 Voltage Offset Correction: v_off_ini = 2373.356 uV, v_off_fin = 2365.929 uV 14:59:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.409 uVs 14:59:40 Integrated Voltage Measurement... 14:59:48 Voltage Offset Correction: v_off_ini = 2361.631 uV, v_off_fin = 2375.680 uV 14:59:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.472 uVs 14:59:49 Integrated Voltage Measurement... 14:59:57 Voltage Offset Correction: v_off_ini = 2350.638 uV, v_off_fin = 2344.694 uV 14:59:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.012 uVs 14:59:58 Integrated Voltage Measurement... 15:00:06 Voltage Offset Correction: v_off_ini = 2369.132 uV, v_off_fin = 2366.418 uV 15:00:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.785 uVs 15:00:07 Integrated Voltage Measurement... 15:00:15 Voltage Offset Correction: v_off_ini = 2350.018 uV, v_off_fin = 2349.561 uV 15:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.865 uVs 15:00:15 Integrated Voltage Measurement... 15:00:24 Voltage Offset Correction: v_off_ini = 2373.128 uV, v_off_fin = 2378.177 uV 15:00:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.837 uVs 15:00:29 I1Y Average and RMS of Measurements VT = -206.563 +- 6.223 uVs I1Y = -41.313 +- 1.245 uTm 15:00:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:36 Integrated Voltage Measurement... 15:00:45 Voltage Offset Correction: v_off_ini = 2338.522 uV, v_off_fin = 2337.996 uV 15:00:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -180.084 uVs 15:00:45 Integrated Voltage Measurement... 15:00:54 Voltage Offset Correction: v_off_ini = 2324.897 uV, v_off_fin = 2332.457 uV 15:00:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 190.429 uVs 15:00:54 Integrated Voltage Measurement... 15:01:03 Voltage Offset Correction: v_off_ini = 2356.224 uV, v_off_fin = 2344.049 uV 15:01:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -183.565 uVs 15:01:03 Integrated Voltage Measurement... 15:01:12 Voltage Offset Correction: v_off_ini = 2355.767 uV, v_off_fin = 2364.424 uV 15:01:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.887 uVs 15:01:12 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 2361.447 uV, v_off_fin = 2369.428 uV 15:01:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.821 uVs 15:01:21 Integrated Voltage Measurement... 15:01:30 Voltage Offset Correction: v_off_ini = 2343.788 uV, v_off_fin = 2354.166 uV 15:01:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 191.043 uVs 15:01:33 I2X Average and RMS of Measurements VT = -185.138 +- 1.108 uVs I2X = 17.033 +- 0.102 uTm^2 15:01:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:41 Integrated Voltage Measurement... 15:01:49 Voltage Offset Correction: v_off_ini = 2329.697 uV, v_off_fin = 2334.827 uV 15:01:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.391 uVs 15:01:50 Integrated Voltage Measurement... 15:01:59 Voltage Offset Correction: v_off_ini = 2341.603 uV, v_off_fin = 2322.916 uV 15:01:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.654 uVs 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 2350.492 uV, v_off_fin = 2357.851 uV 15:02:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.707 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 2338.159 uV, v_off_fin = 2350.893 uV 15:02:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.939 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 2341.073 uV, v_off_fin = 2326.330 uV 15:02:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.659 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 2346.265 uV, v_off_fin = 2352.102 uV 15:02:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.267 uVs 15:02:37 I2Y Average and RMS of Measurements VT = -259.936 +- 5.929 uVs I2Y = -23.914 +- 0.545 uTm^2 15:02:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:52 Integrated Voltage Measurement... 15:03:01 Voltage Offset Correction: v_off_ini = 2352.565 uV, v_off_fin = 2341.807 uV 15:03:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -204.589 uVs 15:03:01 Integrated Voltage Measurement... 15:03:10 Voltage Offset Correction: v_off_ini = 2333.691 uV, v_off_fin = 2366.203 uV 15:03:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.249 uVs 15:03:10 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 2335.912 uV, v_off_fin = 2318.396 uV 15:03:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.077 uVs 15:03:19 Integrated Voltage Measurement... 15:03:28 Voltage Offset Correction: v_off_ini = 2315.825 uV, v_off_fin = 2330.686 uV 15:03:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.897 uVs 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 2335.611 uV, v_off_fin = 2325.948 uV 15:03:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -185.148 uVs 15:03:37 Integrated Voltage Measurement... 15:03:46 Voltage Offset Correction: v_off_ini = 2340.630 uV, v_off_fin = 2341.842 uV 15:03:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.466 uVs 15:03:50 I1X Average and RMS of Measurements VT = -188.071 +- 6.563 uVs I1X = 37.614 +- 1.313 uTm 15:03:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:57 Integrated Voltage Measurement... 15:04:06 Voltage Offset Correction: v_off_ini = 2340.324 uV, v_off_fin = 2310.150 uV 15:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.875 uVs 15:04:06 Integrated Voltage Measurement... 15:04:15 Voltage Offset Correction: v_off_ini = 2340.926 uV, v_off_fin = 2330.106 uV 15:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.316 uVs 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 2330.858 uV, v_off_fin = 2316.381 uV 15:04:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.341 uVs 15:04:24 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 2330.077 uV, v_off_fin = 2342.183 uV 15:04:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.705 uVs 15:04:33 Integrated Voltage Measurement... 15:04:42 Voltage Offset Correction: v_off_ini = 2359.669 uV, v_off_fin = 2346.078 uV 15:04:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.045 uVs 15:04:42 Integrated Voltage Measurement... 15:04:51 Voltage Offset Correction: v_off_ini = 2345.869 uV, v_off_fin = 2345.009 uV 15:04:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.673 uVs 15:04:55 I1Y Average and RMS of Measurements VT = -218.326 +- 7.976 uVs I1Y = -43.665 +- 1.595 uTm 15:05:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:03 Integrated Voltage Measurement... 15:05:12 Voltage Offset Correction: v_off_ini = 2365.394 uV, v_off_fin = 2354.892 uV 15:05:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.472 uVs 15:05:12 Integrated Voltage Measurement... 15:05:21 Voltage Offset Correction: v_off_ini = 2373.146 uV, v_off_fin = 2374.492 uV 15:05:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.862 uVs 15:05:21 Integrated Voltage Measurement... 15:05:30 Voltage Offset Correction: v_off_ini = 2365.094 uV, v_off_fin = 2364.266 uV 15:05:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -202.476 uVs 15:05:30 Integrated Voltage Measurement... 15:05:39 Voltage Offset Correction: v_off_ini = 2380.423 uV, v_off_fin = 2396.452 uV 15:05:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 204.214 uVs 15:05:39 Integrated Voltage Measurement... 15:05:48 Voltage Offset Correction: v_off_ini = 2397.537 uV, v_off_fin = 2386.076 uV 15:05:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -225.716 uVs 15:05:48 Integrated Voltage Measurement... 15:05:57 Voltage Offset Correction: v_off_ini = 2398.085 uV, v_off_fin = 2394.071 uV 15:05:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.477 uVs 15:06:00 I2X Average and RMS of Measurements VT = -197.369 +- 17.830 uVs I2X = 18.158 +- 1.640 uTm^2 15:06:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:07 Integrated Voltage Measurement... 15:06:16 Voltage Offset Correction: v_off_ini = 2371.807 uV, v_off_fin = 2369.198 uV 15:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.297 uVs 15:06:16 Integrated Voltage Measurement... 15:06:25 Voltage Offset Correction: v_off_ini = 2375.275 uV, v_off_fin = 2380.496 uV 15:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.844 uVs 15:06:25 Integrated Voltage Measurement... 15:06:34 Voltage Offset Correction: v_off_ini = 2365.455 uV, v_off_fin = 2354.545 uV 15:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.158 uVs 15:06:34 Integrated Voltage Measurement... 15:06:43 Voltage Offset Correction: v_off_ini = 2347.806 uV, v_off_fin = 2350.907 uV 15:06:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.799 uVs 15:06:44 Integrated Voltage Measurement... 15:06:52 Voltage Offset Correction: v_off_ini = 2342.961 uV, v_off_fin = 2328.266 uV 15:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.840 uVs 15:06:53 Integrated Voltage Measurement... 15:07:02 Voltage Offset Correction: v_off_ini = 2309.171 uV, v_off_fin = 2314.171 uV 15:07:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.286 uVs 15:07:04 I2Y Average and RMS of Measurements VT = -275.371 +- 3.078 uVs I2Y = -25.334 +- 0.283 uTm^2 15:07:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:19 Integrated Voltage Measurement... 15:07:28 Voltage Offset Correction: v_off_ini = 2309.736 uV, v_off_fin = 2306.807 uV 15:07:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -228.984 uVs 15:07:28 Integrated Voltage Measurement... 15:07:37 Voltage Offset Correction: v_off_ini = 2314.198 uV, v_off_fin = 2302.266 uV 15:07:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.022 uVs 15:07:37 Integrated Voltage Measurement... 15:07:46 Voltage Offset Correction: v_off_ini = 2288.219 uV, v_off_fin = 2292.231 uV 15:07:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -192.973 uVs 15:07:46 Integrated Voltage Measurement... 15:07:55 Voltage Offset Correction: v_off_ini = 2289.676 uV, v_off_fin = 2320.249 uV 15:07:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 199.702 uVs 15:07:55 Integrated Voltage Measurement... 15:08:04 Voltage Offset Correction: v_off_ini = 2302.711 uV, v_off_fin = 2304.926 uV 15:08:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -185.946 uVs 15:08:04 Integrated Voltage Measurement... 15:08:13 Voltage Offset Correction: v_off_ini = 2291.532 uV, v_off_fin = 2294.251 uV 15:08:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 187.047 uVs 15:08:17 I1X Average and RMS of Measurements VT = -196.779 +- 8.581 uVs I1X = 39.357 +- 1.717 uTm 15:08:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:24 Integrated Voltage Measurement... 15:08:33 Voltage Offset Correction: v_off_ini = 2319.182 uV, v_off_fin = 2302.115 uV 15:08:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.378 uVs 15:08:33 Integrated Voltage Measurement... 15:08:42 Voltage Offset Correction: v_off_ini = 2312.318 uV, v_off_fin = 2314.271 uV 15:08:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.252 uVs 15:08:42 Integrated Voltage Measurement... 15:08:51 Voltage Offset Correction: v_off_ini = 2311.411 uV, v_off_fin = 2281.029 uV 15:08:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.498 uVs 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = 2283.889 uV, v_off_fin = 2304.393 uV 15:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.870 uVs 15:09:00 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = 2301.564 uV, v_off_fin = 2277.515 uV 15:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.592 uVs 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 2297.217 uV, v_off_fin = 2301.865 uV 15:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.125 uVs 15:09:22 I1Y Average and RMS of Measurements VT = -230.786 +- 1.710 uVs I1Y = -46.157 +- 0.342 uTm 15:09:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:30 Integrated Voltage Measurement... 15:09:39 Voltage Offset Correction: v_off_ini = 2307.955 uV, v_off_fin = 2307.250 uV 15:09:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -180.136 uVs 15:09:39 Integrated Voltage Measurement... 15:09:48 Voltage Offset Correction: v_off_ini = 2317.304 uV, v_off_fin = 2307.924 uV 15:09:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.822 uVs 15:09:48 Integrated Voltage Measurement... 15:09:57 Voltage Offset Correction: v_off_ini = 2289.450 uV, v_off_fin = 2270.872 uV 15:09:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -233.659 uVs 15:09:57 Integrated Voltage Measurement... 15:10:06 Voltage Offset Correction: v_off_ini = 2289.121 uV, v_off_fin = 2298.787 uV 15:10:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 199.412 uVs 15:10:06 Integrated Voltage Measurement... 15:10:15 Voltage Offset Correction: v_off_ini = 2305.708 uV, v_off_fin = 2291.249 uV 15:10:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -194.044 uVs 15:10:15 Integrated Voltage Measurement... 15:10:24 Voltage Offset Correction: v_off_ini = 2291.598 uV, v_off_fin = 2290.130 uV 15:10:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.037 uVs 15:10:26 I2X Average and RMS of Measurements VT = -202.018 +- 10.609 uVs I2X = 18.586 +- 0.976 uTm^2 15:10:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:34 Integrated Voltage Measurement... 15:10:43 Voltage Offset Correction: v_off_ini = 2293.408 uV, v_off_fin = 2276.421 uV 15:10:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.637 uVs 15:10:43 Integrated Voltage Measurement... 15:10:52 Voltage Offset Correction: v_off_ini = 2263.643 uV, v_off_fin = 2275.779 uV 15:10:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.214 uVs 15:10:52 Integrated Voltage Measurement... 15:11:01 Voltage Offset Correction: v_off_ini = 2291.678 uV, v_off_fin = 2302.958 uV 15:11:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.357 uVs 15:11:01 Integrated Voltage Measurement... 15:11:10 Voltage Offset Correction: v_off_ini = 2301.993 uV, v_off_fin = 2290.601 uV 15:11:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.043 uVs 15:11:10 Integrated Voltage Measurement... 15:11:19 Voltage Offset Correction: v_off_ini = 2283.228 uV, v_off_fin = 2299.457 uV 15:11:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.231 uVs 15:11:19 Integrated Voltage Measurement... 15:11:28 Voltage Offset Correction: v_off_ini = 2290.301 uV, v_off_fin = 2299.319 uV 15:11:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.472 uVs 15:11:31 I2Y Average and RMS of Measurements VT = -287.659 +- 7.501 uVs I2Y = -26.465 +- 0.690 uTm^2 15:11:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:46 Integrated Voltage Measurement... 15:11:55 Voltage Offset Correction: v_off_ini = 2303.008 uV, v_off_fin = 2285.281 uV 15:11:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -187.090 uVs 15:11:55 Integrated Voltage Measurement... 15:12:04 Voltage Offset Correction: v_off_ini = 2280.303 uV, v_off_fin = 2296.531 uV 15:12:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 195.386 uVs 15:12:04 Integrated Voltage Measurement... 15:12:13 Voltage Offset Correction: v_off_ini = 2297.665 uV, v_off_fin = 2295.665 uV 15:12:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.052 uVs 15:12:13 Integrated Voltage Measurement... 15:12:22 Voltage Offset Correction: v_off_ini = 2303.283 uV, v_off_fin = 2306.684 uV 15:12:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 224.390 uVs 15:12:22 Integrated Voltage Measurement... 15:12:31 Voltage Offset Correction: v_off_ini = 2296.398 uV, v_off_fin = 2297.164 uV 15:12:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.448 uVs 15:12:31 Integrated Voltage Measurement... 15:12:40 Voltage Offset Correction: v_off_ini = 2293.728 uV, v_off_fin = 2291.387 uV 15:12:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 196.182 uVs 15:12:44 I1X Average and RMS of Measurements VT = -199.758 +- 9.008 uVs I1X = 39.952 +- 1.802 uTm 15:12:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:51 Integrated Voltage Measurement... 15:13:00 Voltage Offset Correction: v_off_ini = 2275.384 uV, v_off_fin = 2283.029 uV 15:13:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.803 uVs 15:13:00 Integrated Voltage Measurement... 15:13:09 Voltage Offset Correction: v_off_ini = 2257.122 uV, v_off_fin = 2264.936 uV 15:13:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.063 uVs 15:13:09 Integrated Voltage Measurement... 15:13:18 Voltage Offset Correction: v_off_ini = 2252.519 uV, v_off_fin = 2231.583 uV 15:13:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.874 uVs 15:13:18 Integrated Voltage Measurement... 15:13:27 Voltage Offset Correction: v_off_ini = 2243.598 uV, v_off_fin = 2245.649 uV 15:13:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.228 uVs 15:13:27 Integrated Voltage Measurement... 15:13:36 Voltage Offset Correction: v_off_ini = 2247.632 uV, v_off_fin = 2238.674 uV 15:13:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.139 uVs 15:13:36 Integrated Voltage Measurement... 15:13:45 Voltage Offset Correction: v_off_ini = 2236.117 uV, v_off_fin = 2236.232 uV 15:13:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.034 uVs 15:13:49 I1Y Average and RMS of Measurements VT = -240.357 +- 2.096 uVs I1Y = -48.071 +- 0.419 uTm 15:13:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:57 Integrated Voltage Measurement... 15:14:06 Voltage Offset Correction: v_off_ini = 2228.990 uV, v_off_fin = 2202.086 uV 15:14:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -225.345 uVs 15:14:06 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = 2203.449 uV, v_off_fin = 2220.317 uV 15:14:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 215.506 uVs 15:14:15 Integrated Voltage Measurement... 15:14:24 Voltage Offset Correction: v_off_ini = 2210.112 uV, v_off_fin = 2188.183 uV 15:14:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -226.522 uVs 15:14:24 Integrated Voltage Measurement... 15:14:33 Voltage Offset Correction: v_off_ini = 2193.829 uV, v_off_fin = 2216.114 uV 15:14:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 217.276 uVs 15:14:33 Integrated Voltage Measurement... 15:14:42 Voltage Offset Correction: v_off_ini = 2195.580 uV, v_off_fin = 2183.630 uV 15:14:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -205.750 uVs 15:14:42 Integrated Voltage Measurement... 15:14:51 Voltage Offset Correction: v_off_ini = 2177.739 uV, v_off_fin = 2195.057 uV 15:14:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 226.701 uVs 15:14:53 I2X Average and RMS of Measurements VT = -219.517 +- 2.404 uVs I2X = 20.196 +- 0.221 uTm^2 15:14:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:01 Integrated Voltage Measurement... 15:15:10 Voltage Offset Correction: v_off_ini = 2169.648 uV, v_off_fin = 2153.953 uV 15:15:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.557 uVs 15:15:10 Integrated Voltage Measurement... 15:15:19 Voltage Offset Correction: v_off_ini = 2159.918 uV, v_off_fin = 2165.935 uV 15:15:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.029 uVs 15:15:19 Integrated Voltage Measurement... 15:15:28 Voltage Offset Correction: v_off_ini = 2174.309 uV, v_off_fin = 2169.921 uV 15:15:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.029 uVs 15:15:28 Integrated Voltage Measurement... 15:15:37 Voltage Offset Correction: v_off_ini = 2168.582 uV, v_off_fin = 2173.759 uV 15:15:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.124 uVs 15:15:37 Integrated Voltage Measurement... 15:15:46 Voltage Offset Correction: v_off_ini = 2162.931 uV, v_off_fin = 2161.404 uV 15:15:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.853 uVs 15:15:46 Integrated Voltage Measurement... 15:15:55 Voltage Offset Correction: v_off_ini = 2176.522 uV, v_off_fin = 2172.229 uV 15:15:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.240 uVs 15:15:57 I2Y Average and RMS of Measurements VT = -299.305 +- 1.942 uVs I2Y = -27.536 +- 0.179 uTm^2 15:16:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:12 Integrated Voltage Measurement... 15:16:21 Voltage Offset Correction: v_off_ini = 2174.433 uV, v_off_fin = 2174.923 uV 15:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -224.118 uVs 15:16:21 Integrated Voltage Measurement... 15:16:30 Voltage Offset Correction: v_off_ini = 2178.154 uV, v_off_fin = 2176.582 uV 15:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 204.761 uVs 15:16:30 Integrated Voltage Measurement... 15:16:39 Voltage Offset Correction: v_off_ini = 2170.975 uV, v_off_fin = 2158.992 uV 15:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -229.427 uVs 15:16:39 Integrated Voltage Measurement... 15:16:48 Voltage Offset Correction: v_off_ini = 2148.143 uV, v_off_fin = 2161.693 uV 15:16:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 213.655 uVs 15:16:48 Integrated Voltage Measurement... 15:16:57 Voltage Offset Correction: v_off_ini = 2136.554 uV, v_off_fin = 2151.307 uV 15:16:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -214.160 uVs 15:16:57 Integrated Voltage Measurement... 15:17:06 Voltage Offset Correction: v_off_ini = 2151.796 uV, v_off_fin = 2169.227 uV 15:17:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 214.171 uVs 15:17:11 I1X Average and RMS of Measurements VT = -216.715 +- 3.414 uVs I1X = 43.345 +- 0.682 uTm 15:17:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:17 Integrated Voltage Measurement... 15:17:26 Voltage Offset Correction: v_off_ini = 2124.371 uV, v_off_fin = 2125.739 uV 15:17:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -225.993 uVs 15:17:26 Integrated Voltage Measurement... 15:17:35 Voltage Offset Correction: v_off_ini = 2131.928 uV, v_off_fin = 2139.558 uV 15:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.567 uVs 15:17:35 Integrated Voltage Measurement... 15:17:44 Voltage Offset Correction: v_off_ini = 2112.639 uV, v_off_fin = 2112.375 uV 15:17:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.517 uVs 15:17:44 Integrated Voltage Measurement... 15:17:53 Voltage Offset Correction: v_off_ini = 2106.289 uV, v_off_fin = 2118.431 uV 15:17:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.889 uVs 15:17:53 Integrated Voltage Measurement... 15:18:02 Voltage Offset Correction: v_off_ini = 2089.210 uV, v_off_fin = 2083.948 uV 15:18:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.997 uVs 15:18:02 Integrated Voltage Measurement... 15:18:11 Voltage Offset Correction: v_off_ini = 2092.424 uV, v_off_fin = 2117.194 uV 15:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.142 uVs 15:18:16 I1Y Average and RMS of Measurements VT = -241.017 +- 3.518 uVs I1Y = -48.204 +- 0.703 uTm 15:18:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:23 Integrated Voltage Measurement... 15:18:32 Voltage Offset Correction: v_off_ini = 2104.451 uV, v_off_fin = 2099.158 uV 15:18:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -234.078 uVs 15:18:32 Integrated Voltage Measurement... 15:18:41 Voltage Offset Correction: v_off_ini = 2092.337 uV, v_off_fin = 2095.633 uV 15:18:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 222.280 uVs 15:18:41 Integrated Voltage Measurement... 15:18:50 Voltage Offset Correction: v_off_ini = 2093.103 uV, v_off_fin = 2089.686 uV 15:18:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -244.565 uVs 15:18:50 Integrated Voltage Measurement... 15:18:59 Voltage Offset Correction: v_off_ini = 2093.924 uV, v_off_fin = 2091.702 uV 15:18:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 196.018 uVs 15:18:59 Integrated Voltage Measurement... 15:19:08 Voltage Offset Correction: v_off_ini = 2108.327 uV, v_off_fin = 2087.742 uV 15:19:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -239.914 uVs 15:19:08 Integrated Voltage Measurement... 15:19:17 Voltage Offset Correction: v_off_ini = 2083.103 uV, v_off_fin = 2099.578 uV 15:19:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 227.033 uVs 15:19:20 I2X Average and RMS of Measurements VT = -227.315 +- 5.416 uVs I2X = 20.913 +- 0.498 uTm^2 15:19:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:28 Integrated Voltage Measurement... 15:19:36 Voltage Offset Correction: v_off_ini = 2093.275 uV, v_off_fin = 2087.554 uV 15:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.083 uVs 15:19:37 Integrated Voltage Measurement... 15:19:46 Voltage Offset Correction: v_off_ini = 2102.001 uV, v_off_fin = 2105.043 uV 15:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.192 uVs 15:19:46 Integrated Voltage Measurement... 15:19:55 Voltage Offset Correction: v_off_ini = 2104.515 uV, v_off_fin = 2103.663 uV 15:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.059 uVs 15:19:55 Integrated Voltage Measurement... 15:20:04 Voltage Offset Correction: v_off_ini = 2077.527 uV, v_off_fin = 2104.202 uV 15:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.269 uVs 15:20:04 Integrated Voltage Measurement... 15:20:13 Voltage Offset Correction: v_off_ini = 2102.334 uV, v_off_fin = 2084.333 uV 15:20:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.523 uVs 15:20:13 Integrated Voltage Measurement... 15:20:22 Voltage Offset Correction: v_off_ini = 2091.621 uV, v_off_fin = 2115.106 uV 15:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.764 uVs 15:20:24 I2Y Average and RMS of Measurements VT = -295.148 +- 9.908 uVs I2Y = -27.154 +- 0.912 uTm^2 15:20:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:39 Integrated Voltage Measurement... 15:20:48 Voltage Offset Correction: v_off_ini = 2108.497 uV, v_off_fin = 2095.281 uV 15:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -245.163 uVs 15:20:48 Integrated Voltage Measurement... 15:20:57 Voltage Offset Correction: v_off_ini = 2071.142 uV, v_off_fin = 2080.574 uV 15:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 212.543 uVs 15:20:57 Integrated Voltage Measurement... 15:21:06 Voltage Offset Correction: v_off_ini = 2062.982 uV, v_off_fin = 2058.712 uV 15:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -209.855 uVs 15:21:06 Integrated Voltage Measurement... 15:21:15 Voltage Offset Correction: v_off_ini = 2067.228 uV, v_off_fin = 2095.432 uV 15:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 221.321 uVs 15:21:15 Integrated Voltage Measurement... 15:21:24 Voltage Offset Correction: v_off_ini = 2096.411 uV, v_off_fin = 2078.290 uV 15:21:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -214.915 uVs 15:21:24 Integrated Voltage Measurement... 15:21:33 Voltage Offset Correction: v_off_ini = 2046.183 uV, v_off_fin = 2074.257 uV 15:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 224.254 uVs 15:21:37 I1X Average and RMS of Measurements VT = -221.342 +- 5.556 uVs I1X = 44.269 +- 1.112 uTm 15:21:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:44 Integrated Voltage Measurement... 15:21:53 Voltage Offset Correction: v_off_ini = 2095.941 uV, v_off_fin = 2085.676 uV 15:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.974 uVs 15:21:53 Integrated Voltage Measurement... 15:22:02 Voltage Offset Correction: v_off_ini = 2079.420 uV, v_off_fin = 2093.385 uV 15:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.513 uVs 15:22:02 Integrated Voltage Measurement... 15:22:11 Voltage Offset Correction: v_off_ini = 2081.200 uV, v_off_fin = 2069.335 uV 15:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.927 uVs 15:22:11 Integrated Voltage Measurement... 15:22:20 Voltage Offset Correction: v_off_ini = 2087.911 uV, v_off_fin = 2101.753 uV 15:22:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.870 uVs 15:22:20 Integrated Voltage Measurement... 15:22:29 Voltage Offset Correction: v_off_ini = 2088.539 uV, v_off_fin = 2060.450 uV 15:22:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.085 uVs 15:22:29 Integrated Voltage Measurement... 15:22:38 Voltage Offset Correction: v_off_ini = 2075.744 uV, v_off_fin = 2105.593 uV 15:22:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.944 uVs 15:22:42 I1Y Average and RMS of Measurements VT = -245.552 +- 6.379 uVs I1Y = -49.110 +- 1.275 uTm 15:22:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:50 Integrated Voltage Measurement... 15:22:59 Voltage Offset Correction: v_off_ini = 2064.277 uV, v_off_fin = 2048.482 uV 15:22:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -245.447 uVs 15:22:59 Integrated Voltage Measurement... 15:23:08 Voltage Offset Correction: v_off_ini = 2050.302 uV, v_off_fin = 2066.209 uV 15:23:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 240.094 uVs 15:23:08 Integrated Voltage Measurement... 15:23:17 Voltage Offset Correction: v_off_ini = 2063.834 uV, v_off_fin = 2039.156 uV 15:23:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -247.803 uVs 15:23:17 Integrated Voltage Measurement... 15:23:26 Voltage Offset Correction: v_off_ini = 2076.322 uV, v_off_fin = 2080.918 uV 15:23:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 235.212 uVs 15:23:26 Integrated Voltage Measurement... 15:23:35 Voltage Offset Correction: v_off_ini = 2079.686 uV, v_off_fin = 2044.307 uV 15:23:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -233.769 uVs 15:23:35 Integrated Voltage Measurement... 15:23:44 Voltage Offset Correction: v_off_ini = 2063.487 uV, v_off_fin = 2081.738 uV 15:23:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 238.553 uVs 15:23:46 I2X Average and RMS of Measurements VT = -240.146 +- 2.865 uVs I2X = 22.093 +- 0.264 uTm^2 15:23:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:54 Integrated Voltage Measurement... 15:24:03 Voltage Offset Correction: v_off_ini = 2072.168 uV, v_off_fin = 2059.274 uV 15:24:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -304.406 uVs 15:24:03 Integrated Voltage Measurement... 15:24:12 Voltage Offset Correction: v_off_ini = 2063.181 uV, v_off_fin = 2060.179 uV 15:24:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.481 uVs 15:24:12 Integrated Voltage Measurement... 15:24:21 Voltage Offset Correction: v_off_ini = 2052.027 uV, v_off_fin = 2047.152 uV 15:24:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.250 uVs 15:24:21 Integrated Voltage Measurement... 15:24:30 Voltage Offset Correction: v_off_ini = 2074.122 uV, v_off_fin = 2055.375 uV 15:24:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.913 uVs 15:24:30 Integrated Voltage Measurement... 15:24:39 Voltage Offset Correction: v_off_ini = 2054.060 uV, v_off_fin = 2030.672 uV 15:24:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.962 uVs 15:24:39 Integrated Voltage Measurement... 15:24:48 Voltage Offset Correction: v_off_ini = 2031.840 uV, v_off_fin = 2042.591 uV 15:24:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.880 uVs 15:24:51 I2Y Average and RMS of Measurements VT = -302.649 +- 7.237 uVs I2Y = -27.844 +- 0.666 uTm^2 15:25:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:06 Integrated Voltage Measurement... 15:25:15 Voltage Offset Correction: v_off_ini = 2028.716 uV, v_off_fin = 2007.951 uV 15:25:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -210.511 uVs 15:25:15 Integrated Voltage Measurement... 15:25:23 Voltage Offset Correction: v_off_ini = 2014.476 uV, v_off_fin = 2037.854 uV 15:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 220.836 uVs 15:25:24 Integrated Voltage Measurement... 15:25:33 Voltage Offset Correction: v_off_ini = 2032.243 uV, v_off_fin = 2020.209 uV 15:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -213.837 uVs 15:25:33 Integrated Voltage Measurement... 15:25:41 Voltage Offset Correction: v_off_ini = 2015.706 uV, v_off_fin = 2026.300 uV 15:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 222.754 uVs 15:25:42 Integrated Voltage Measurement... 15:25:50 Voltage Offset Correction: v_off_ini = 2008.385 uV, v_off_fin = 1998.467 uV 15:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -216.473 uVs 15:25:51 Integrated Voltage Measurement... 15:25:59 Voltage Offset Correction: v_off_ini = 2006.723 uV, v_off_fin = 2007.792 uV 15:25:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 225.473 uVs 15:26:04 I1X Average and RMS of Measurements VT = -218.314 +- 2.163 uVs I1X = 43.664 +- 0.431 uTm 15:26:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:10 Integrated Voltage Measurement... 15:26:19 Voltage Offset Correction: v_off_ini = 2001.893 uV, v_off_fin = 1982.888 uV 15:26:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -245.600 uVs 15:26:19 Integrated Voltage Measurement... 15:26:28 Voltage Offset Correction: v_off_ini = 2004.748 uV, v_off_fin = 1999.242 uV 15:26:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.164 uVs 15:26:28 Integrated Voltage Measurement... 15:26:37 Voltage Offset Correction: v_off_ini = 1977.921 uV, v_off_fin = 1963.227 uV 15:26:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -246.195 uVs 15:26:37 Integrated Voltage Measurement... 15:26:46 Voltage Offset Correction: v_off_ini = 1991.883 uV, v_off_fin = 2006.994 uV 15:26:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.009 uVs 15:26:46 Integrated Voltage Measurement... 15:26:55 Voltage Offset Correction: v_off_ini = 1975.140 uV, v_off_fin = 1949.279 uV 15:26:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.018 uVs 15:26:55 Integrated Voltage Measurement... 15:27:04 Voltage Offset Correction: v_off_ini = 1972.559 uV, v_off_fin = 1970.184 uV 15:27:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.594 uVs 15:27:08 I1Y Average and RMS of Measurements VT = -250.263 +- 1.418 uVs I1Y = -50.052 +- 0.282 uTm 15:27:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:16 Integrated Voltage Measurement... 15:27:25 Voltage Offset Correction: v_off_ini = 1959.270 uV, v_off_fin = 1939.541 uV 15:27:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -244.573 uVs 15:27:25 Integrated Voltage Measurement... 15:27:34 Voltage Offset Correction: v_off_ini = 1946.716 uV, v_off_fin = 1950.692 uV 15:27:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 246.151 uVs 15:27:34 Integrated Voltage Measurement... 15:27:43 Voltage Offset Correction: v_off_ini = 1933.028 uV, v_off_fin = 1927.137 uV 15:27:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -247.617 uVs 15:27:43 Integrated Voltage Measurement... 15:27:52 Voltage Offset Correction: v_off_ini = 1938.972 uV, v_off_fin = 1953.868 uV 15:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 233.429 uVs 15:27:52 Integrated Voltage Measurement... 15:28:01 Voltage Offset Correction: v_off_ini = 1953.206 uV, v_off_fin = 1951.890 uV 15:28:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -256.803 uVs 15:28:01 Integrated Voltage Measurement... 15:28:10 Voltage Offset Correction: v_off_ini = 1937.748 uV, v_off_fin = 1942.432 uV 15:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 237.026 uVs 15:28:13 I2X Average and RMS of Measurements VT = -244.266 +- 2.722 uVs I2X = 22.472 +- 0.250 uTm^2 15:28:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:20 Integrated Voltage Measurement... 15:28:29 Voltage Offset Correction: v_off_ini = 1950.337 uV, v_off_fin = 1937.806 uV 15:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.670 uVs 15:28:29 Integrated Voltage Measurement... 15:28:38 Voltage Offset Correction: v_off_ini = 1938.786 uV, v_off_fin = 1945.537 uV 15:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.054 uVs 15:28:38 Integrated Voltage Measurement... 15:28:47 Voltage Offset Correction: v_off_ini = 1925.619 uV, v_off_fin = 1940.772 uV 15:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.692 uVs 15:28:47 Integrated Voltage Measurement... 15:28:56 Voltage Offset Correction: v_off_ini = 1931.508 uV, v_off_fin = 1930.627 uV 15:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.397 uVs 15:28:56 Integrated Voltage Measurement... 15:29:05 Voltage Offset Correction: v_off_ini = 1915.886 uV, v_off_fin = 1933.026 uV 15:29:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.454 uVs 15:29:05 Integrated Voltage Measurement... 15:29:14 Voltage Offset Correction: v_off_ini = 1941.283 uV, v_off_fin = 1927.322 uV 15:29:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.975 uVs 15:29:17 I2Y Average and RMS of Measurements VT = -307.540 +- 12.202 uVs I2Y = -28.294 +- 1.123 uTm^2 15:29:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:32 Integrated Voltage Measurement... 15:29:41 Voltage Offset Correction: v_off_ini = 1925.077 uV, v_off_fin = 1917.464 uV 15:29:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -248.412 uVs 15:29:41 Integrated Voltage Measurement... 15:29:50 Voltage Offset Correction: v_off_ini = 1931.319 uV, v_off_fin = 1927.971 uV 15:29:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 258.316 uVs 15:29:50 Integrated Voltage Measurement... 15:29:59 Voltage Offset Correction: v_off_ini = 1919.074 uV, v_off_fin = 1893.270 uV 15:29:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -243.453 uVs 15:29:59 Integrated Voltage Measurement... 15:30:08 Voltage Offset Correction: v_off_ini = 1902.584 uV, v_off_fin = 1906.524 uV 15:30:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 240.531 uVs 15:30:08 Integrated Voltage Measurement... 15:30:17 Voltage Offset Correction: v_off_ini = 1906.528 uV, v_off_fin = 1911.267 uV 15:30:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -234.097 uVs 15:30:17 Integrated Voltage Measurement... 15:30:26 Voltage Offset Correction: v_off_ini = 1920.260 uV, v_off_fin = 1912.953 uV 15:30:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 228.898 uVs 15:30:30 I1X Average and RMS of Measurements VT = -242.285 +- 8.929 uVs I1X = 48.459 +- 1.786 uTm 15:30:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:37 Integrated Voltage Measurement... 15:30:46 Voltage Offset Correction: v_off_ini = 1891.709 uV, v_off_fin = 1872.503 uV 15:30:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.533 uVs 15:30:46 Integrated Voltage Measurement... 15:30:54 Voltage Offset Correction: v_off_ini = 1876.715 uV, v_off_fin = 1897.940 uV 15:30:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.952 uVs 15:30:55 Integrated Voltage Measurement... 15:31:03 Voltage Offset Correction: v_off_ini = 1899.072 uV, v_off_fin = 1876.937 uV 15:31:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -268.199 uVs 15:31:03 Integrated Voltage Measurement... 15:31:12 Voltage Offset Correction: v_off_ini = 1876.636 uV, v_off_fin = 1890.879 uV 15:31:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.688 uVs 15:31:12 Integrated Voltage Measurement... 15:31:21 Voltage Offset Correction: v_off_ini = 1880.644 uV, v_off_fin = 1872.686 uV 15:31:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.521 uVs 15:31:21 Integrated Voltage Measurement... 15:31:30 Voltage Offset Correction: v_off_ini = 1891.898 uV, v_off_fin = 1893.409 uV 15:31:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.646 uVs 15:31:35 I1Y Average and RMS of Measurements VT = -260.923 +- 8.984 uVs I1Y = -52.184 +- 1.796 uTm 15:31:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:42 Integrated Voltage Measurement... 15:31:51 Voltage Offset Correction: v_off_ini = 1892.846 uV, v_off_fin = 1889.585 uV 15:31:51 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -244.489 uVs 15:31:51 Integrated Voltage Measurement... 15:32:00 Voltage Offset Correction: v_off_ini = 1911.972 uV, v_off_fin = 1923.106 uV 15:32:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 248.078 uVs 15:32:00 Integrated Voltage Measurement... 15:32:09 Voltage Offset Correction: v_off_ini = 1896.115 uV, v_off_fin = 1882.969 uV 15:32:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -253.981 uVs 15:32:09 Integrated Voltage Measurement... 15:32:18 Voltage Offset Correction: v_off_ini = 1884.614 uV, v_off_fin = 1899.057 uV 15:32:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 239.715 uVs 15:32:18 Integrated Voltage Measurement... 15:32:27 Voltage Offset Correction: v_off_ini = 1887.344 uV, v_off_fin = 1878.411 uV 15:32:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -257.974 uVs 15:32:27 Integrated Voltage Measurement... 15:32:36 Voltage Offset Correction: v_off_ini = 1883.412 uV, v_off_fin = 1908.009 uV 15:32:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 262.200 uVs 15:32:39 I2X Average and RMS of Measurements VT = -251.073 +- 6.378 uVs I2X = 23.098 +- 0.587 uTm^2 15:32:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:46 Integrated Voltage Measurement... 15:32:55 Voltage Offset Correction: v_off_ini = 1864.643 uV, v_off_fin = 1887.020 uV 15:32:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.242 uVs 15:32:55 Integrated Voltage Measurement... 15:33:04 Voltage Offset Correction: v_off_ini = 1905.566 uV, v_off_fin = 1881.794 uV 15:33:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.683 uVs 15:33:04 Integrated Voltage Measurement... 15:33:13 Voltage Offset Correction: v_off_ini = 1875.007 uV, v_off_fin = 1881.239 uV 15:33:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.114 uVs 15:33:13 Integrated Voltage Measurement... 15:33:22 Voltage Offset Correction: v_off_ini = 1876.574 uV, v_off_fin = 1889.061 uV 15:33:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.681 uVs 15:33:22 Integrated Voltage Measurement... 15:33:31 Voltage Offset Correction: v_off_ini = 1880.906 uV, v_off_fin = 1884.513 uV 15:33:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.381 uVs 15:33:31 Integrated Voltage Measurement... 15:33:40 Voltage Offset Correction: v_off_ini = 1877.375 uV, v_off_fin = 1890.305 uV 15:33:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.278 uVs 15:33:43 I2Y Average and RMS of Measurements VT = -319.730 +- 6.161 uVs I2Y = -29.415 +- 0.567 uTm^2 15:33:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:58 Integrated Voltage Measurement... 15:34:07 Voltage Offset Correction: v_off_ini = 1916.512 uV, v_off_fin = 1917.077 uV 15:34:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -271.454 uVs 15:34:07 Integrated Voltage Measurement... 15:34:16 Voltage Offset Correction: v_off_ini = 1891.920 uV, v_off_fin = 1888.848 uV 15:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 247.328 uVs 15:34:16 Integrated Voltage Measurement... 15:34:25 Voltage Offset Correction: v_off_ini = 1879.226 uV, v_off_fin = 1894.432 uV 15:34:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -244.313 uVs 15:34:25 Integrated Voltage Measurement... 15:34:34 Voltage Offset Correction: v_off_ini = 1882.536 uV, v_off_fin = 1884.768 uV 15:34:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 247.479 uVs 15:34:34 Integrated Voltage Measurement... 15:34:43 Voltage Offset Correction: v_off_ini = 1886.631 uV, v_off_fin = 1890.766 uV 15:34:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -242.834 uVs 15:34:43 Integrated Voltage Measurement... 15:34:52 Voltage Offset Correction: v_off_ini = 1889.982 uV, v_off_fin = 1922.609 uV 15:34:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 262.195 uVs 15:34:56 I1X Average and RMS of Measurements VT = -252.600 +- 5.510 uVs I1X = 50.524 +- 1.104 uTm 15:34:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:03 Integrated Voltage Measurement... 15:35:12 Voltage Offset Correction: v_off_ini = 1908.093 uV, v_off_fin = 1907.656 uV 15:35:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.276 uVs 15:35:12 Integrated Voltage Measurement... 15:35:21 Voltage Offset Correction: v_off_ini = 1944.257 uV, v_off_fin = 1946.686 uV 15:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.829 uVs 15:35:21 Integrated Voltage Measurement... 15:35:30 Voltage Offset Correction: v_off_ini = 1936.442 uV, v_off_fin = 1914.400 uV 15:35:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.283 uVs 15:35:30 Integrated Voltage Measurement... 15:35:38 Voltage Offset Correction: v_off_ini = 1913.904 uV, v_off_fin = 1911.549 uV 15:35:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.710 uVs 15:35:39 Integrated Voltage Measurement... 15:35:47 Voltage Offset Correction: v_off_ini = 1899.420 uV, v_off_fin = 1894.449 uV 15:35:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.821 uVs 15:35:48 Integrated Voltage Measurement... 15:35:56 Voltage Offset Correction: v_off_ini = 1916.887 uV, v_off_fin = 1929.029 uV 15:35:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.595 uVs 15:36:01 I1Y Average and RMS of Measurements VT = -263.252 +- 5.144 uVs I1Y = -52.650 +- 1.029 uTm 15:36:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:08 Integrated Voltage Measurement... 15:36:17 Voltage Offset Correction: v_off_ini = 1909.145 uV, v_off_fin = 1905.927 uV 15:36:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -254.339 uVs 15:36:17 Integrated Voltage Measurement... 15:36:26 Voltage Offset Correction: v_off_ini = 1926.047 uV, v_off_fin = 1920.104 uV 15:36:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 257.384 uVs 15:36:26 Integrated Voltage Measurement... 15:36:35 Voltage Offset Correction: v_off_ini = 1944.180 uV, v_off_fin = 1910.495 uV 15:36:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -256.405 uVs 15:36:35 Integrated Voltage Measurement... 15:36:44 Voltage Offset Correction: v_off_ini = 1935.724 uV, v_off_fin = 1939.266 uV 15:36:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 282.080 uVs 15:36:45 Integrated Voltage Measurement... 15:36:53 Voltage Offset Correction: v_off_ini = 1948.984 uV, v_off_fin = 1941.154 uV 15:36:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -241.305 uVs 15:36:54 Integrated Voltage Measurement... 15:37:03 Voltage Offset Correction: v_off_ini = 1930.707 uV, v_off_fin = 1953.864 uV 15:37:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 253.196 uVs 15:37:05 I2X Average and RMS of Measurements VT = -257.451 +- 9.048 uVs I2X = 23.686 +- 0.834 uTm^2 15:37:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:13 Integrated Voltage Measurement... 15:37:22 Voltage Offset Correction: v_off_ini = 1959.750 uV, v_off_fin = 1948.962 uV 15:37:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -317.678 uVs 15:37:22 Integrated Voltage Measurement... 15:37:31 Voltage Offset Correction: v_off_ini = 1962.787 uV, v_off_fin = 1930.903 uV 15:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.222 uVs 15:37:31 Integrated Voltage Measurement... 15:37:40 Voltage Offset Correction: v_off_ini = 1948.130 uV, v_off_fin = 1948.966 uV 15:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.854 uVs 15:37:40 Integrated Voltage Measurement... 15:37:49 Voltage Offset Correction: v_off_ini = 1951.334 uV, v_off_fin = 1958.650 uV 15:37:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.518 uVs 15:37:49 Integrated Voltage Measurement... 15:37:58 Voltage Offset Correction: v_off_ini = 1962.003 uV, v_off_fin = 1965.618 uV 15:37:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.930 uVs 15:37:58 Integrated Voltage Measurement... 15:38:07 Voltage Offset Correction: v_off_ini = 1968.168 uV, v_off_fin = 1977.934 uV 15:38:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.173 uVs 15:38:09 I2Y Average and RMS of Measurements VT = -315.229 +- 6.883 uVs I2Y = -29.001 +- 0.633 uTm^2 15:38:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:25 Integrated Voltage Measurement... 15:38:34 Voltage Offset Correction: v_off_ini = 1962.908 uV, v_off_fin = 1993.197 uV 15:38:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -240.955 uVs 15:38:34 Integrated Voltage Measurement... 15:38:43 Voltage Offset Correction: v_off_ini = 1980.087 uV, v_off_fin = 1985.097 uV 15:38:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 254.262 uVs 15:38:43 Integrated Voltage Measurement... 15:38:52 Voltage Offset Correction: v_off_ini = 1981.817 uV, v_off_fin = 1967.968 uV 15:38:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -254.240 uVs 15:38:52 Integrated Voltage Measurement... 15:39:01 Voltage Offset Correction: v_off_ini = 1984.542 uV, v_off_fin = 1979.293 uV 15:39:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 264.098 uVs 15:39:01 Integrated Voltage Measurement... 15:39:10 Voltage Offset Correction: v_off_ini = 1967.606 uV, v_off_fin = 1969.313 uV 15:39:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -255.352 uVs 15:39:10 Integrated Voltage Measurement... 15:39:19 Voltage Offset Correction: v_off_ini = 1979.115 uV, v_off_fin = 1989.262 uV 15:39:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 238.116 uVs 15:39:24 I1X Average and RMS of Measurements VT = -251.170 +- 5.667 uVs I1X = 50.236 +- 1.132 uTm 15:39:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:30 Integrated Voltage Measurement... 15:39:39 Voltage Offset Correction: v_off_ini = 1960.628 uV, v_off_fin = 1934.368 uV 15:39:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -269.806 uVs 15:39:39 Integrated Voltage Measurement... 15:39:48 Voltage Offset Correction: v_off_ini = 1941.754 uV, v_off_fin = 1973.432 uV 15:39:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.598 uVs 15:39:48 Integrated Voltage Measurement... 15:39:57 Voltage Offset Correction: v_off_ini = 1954.662 uV, v_off_fin = 1944.227 uV 15:39:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.672 uVs 15:39:57 Integrated Voltage Measurement... 15:40:06 Voltage Offset Correction: v_off_ini = 1949.643 uV, v_off_fin = 1965.985 uV 15:40:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.391 uVs 15:40:06 Integrated Voltage Measurement... 15:40:15 Voltage Offset Correction: v_off_ini = 1941.578 uV, v_off_fin = 1932.564 uV 15:40:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -288.415 uVs 15:40:15 Integrated Voltage Measurement... 15:40:24 Voltage Offset Correction: v_off_ini = 1955.928 uV, v_off_fin = 1968.526 uV 15:40:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 266.875 uVs 15:40:28 I1Y Average and RMS of Measurements VT = -277.793 +- 4.626 uVs I1Y = -55.557 +- 0.924 uTm 15:40:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:36 Integrated Voltage Measurement... 15:40:45 Voltage Offset Correction: v_off_ini = 1941.335 uV, v_off_fin = 1930.744 uV 15:40:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -267.924 uVs 15:40:45 Integrated Voltage Measurement... 15:40:54 Voltage Offset Correction: v_off_ini = 1937.508 uV, v_off_fin = 1958.708 uV 15:40:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 254.318 uVs 15:40:54 Integrated Voltage Measurement... 15:41:03 Voltage Offset Correction: v_off_ini = 1952.774 uV, v_off_fin = 1936.587 uV 15:41:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -258.572 uVs 15:41:03 Integrated Voltage Measurement... 15:41:12 Voltage Offset Correction: v_off_ini = 1952.343 uV, v_off_fin = 1960.196 uV 15:41:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 255.807 uVs 15:41:12 Integrated Voltage Measurement... 15:41:21 Voltage Offset Correction: v_off_ini = 1962.638 uV, v_off_fin = 1948.670 uV 15:41:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -287.307 uVs 15:41:21 Integrated Voltage Measurement... 15:41:30 Voltage Offset Correction: v_off_ini = 1962.087 uV, v_off_fin = 1970.419 uV 15:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 266.632 uVs 15:41:33 I2X Average and RMS of Measurements VT = -265.094 +- 8.550 uVs I2X = 24.389 +- 0.787 uTm^2 15:41:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:40 Integrated Voltage Measurement... 15:41:49 Voltage Offset Correction: v_off_ini = 1925.892 uV, v_off_fin = 1933.971 uV 15:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.090 uVs 15:41:49 Integrated Voltage Measurement... 15:41:58 Voltage Offset Correction: v_off_ini = 1925.211 uV, v_off_fin = 1946.413 uV 15:41:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.350 uVs 15:41:58 Integrated Voltage Measurement... 15:42:07 Voltage Offset Correction: v_off_ini = 1948.602 uV, v_off_fin = 1932.232 uV 15:42:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.960 uVs 15:42:07 Integrated Voltage Measurement... 15:42:16 Voltage Offset Correction: v_off_ini = 1920.434 uV, v_off_fin = 1918.224 uV 15:42:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.663 uVs 15:42:16 Integrated Voltage Measurement... 15:42:25 Voltage Offset Correction: v_off_ini = 1935.517 uV, v_off_fin = 1930.566 uV 15:42:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.390 uVs 15:42:25 Integrated Voltage Measurement... 15:42:34 Voltage Offset Correction: v_off_ini = 1930.026 uV, v_off_fin = 1926.583 uV 15:42:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.624 uVs 15:42:37 I2Y Average and RMS of Measurements VT = -328.513 +- 7.925 uVs I2Y = -30.223 +- 0.729 uTm^2 15:42:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:54 Integrated Voltage Measurement... 15:43:03 Voltage Offset Correction: v_off_ini = 1938.654 uV, v_off_fin = 1934.951 uV 15:43:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -241.592 uVs 15:43:03 Integrated Voltage Measurement... 15:43:12 Voltage Offset Correction: v_off_ini = 1956.782 uV, v_off_fin = 1942.638 uV 15:43:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 226.408 uVs 15:43:12 Integrated Voltage Measurement... 15:43:21 Voltage Offset Correction: v_off_ini = 1940.431 uV, v_off_fin = 1933.470 uV 15:43:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -281.184 uVs 15:43:21 Integrated Voltage Measurement... 15:43:30 Voltage Offset Correction: v_off_ini = 1936.612 uV, v_off_fin = 1937.875 uV 15:43:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 255.757 uVs 15:43:30 Integrated Voltage Measurement... 15:43:39 Voltage Offset Correction: v_off_ini = 1925.039 uV, v_off_fin = 1930.660 uV 15:43:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -257.384 uVs 15:43:39 Integrated Voltage Measurement... 15:43:48 Voltage Offset Correction: v_off_ini = 1916.723 uV, v_off_fin = 1914.325 uV 15:43:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 249.545 uVs 15:43:52 I1X Average and RMS of Measurements VT = -251.978 +- 14.112 uVs I1X = 50.396 +- 2.822 uTm 15:43:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:59 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = 1929.616 uV, v_off_fin = 1902.674 uV 15:44:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -276.054 uVs 15:44:08 Integrated Voltage Measurement... 15:44:17 Voltage Offset Correction: v_off_ini = 1903.308 uV, v_off_fin = 1915.999 uV 15:44:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 279.758 uVs 15:44:17 Integrated Voltage Measurement... 15:44:26 Voltage Offset Correction: v_off_ini = 1909.650 uV, v_off_fin = 1902.823 uV 15:44:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.450 uVs 15:44:26 Integrated Voltage Measurement... 15:44:35 Voltage Offset Correction: v_off_ini = 1915.853 uV, v_off_fin = 1939.306 uV 15:44:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.128 uVs 15:44:35 Integrated Voltage Measurement... 15:44:44 Voltage Offset Correction: v_off_ini = 1905.514 uV, v_off_fin = 1891.233 uV 15:44:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -289.030 uVs 15:44:44 Integrated Voltage Measurement... 15:44:53 Voltage Offset Correction: v_off_ini = 1912.445 uV, v_off_fin = 1925.981 uV 15:44:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.755 uVs 15:44:57 I1Y Average and RMS of Measurements VT = -277.363 +- 2.320 uVs I1Y = -55.470 +- 0.462 uTm 15:45:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:05 Integrated Voltage Measurement... 15:45:14 Voltage Offset Correction: v_off_ini = 1900.038 uV, v_off_fin = 1917.770 uV 15:45:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -269.744 uVs 15:45:14 Integrated Voltage Measurement... 15:45:23 Voltage Offset Correction: v_off_ini = 1918.957 uV, v_off_fin = 1919.058 uV 15:45:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 253.245 uVs 15:45:23 Integrated Voltage Measurement... 15:45:32 Voltage Offset Correction: v_off_ini = 1929.769 uV, v_off_fin = 1911.846 uV 15:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -274.985 uVs 15:45:32 Integrated Voltage Measurement... 15:45:41 Voltage Offset Correction: v_off_ini = 1917.376 uV, v_off_fin = 1933.120 uV 15:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 249.102 uVs 15:45:41 Integrated Voltage Measurement... 15:45:50 Voltage Offset Correction: v_off_ini = 1901.302 uV, v_off_fin = 1904.825 uV 15:45:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -266.711 uVs 15:45:50 Integrated Voltage Measurement... 15:45:59 Voltage Offset Correction: v_off_ini = 1923.527 uV, v_off_fin = 1925.542 uV 15:45:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 266.004 uVs 15:46:01 I2X Average and RMS of Measurements VT = -263.298 +- 2.175 uVs I2X = 24.223 +- 0.200 uTm^2 15:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:09 Integrated Voltage Measurement... 15:46:18 Voltage Offset Correction: v_off_ini = 1919.026 uV, v_off_fin = 1935.097 uV 15:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.512 uVs 15:46:18 Integrated Voltage Measurement... 15:46:27 Voltage Offset Correction: v_off_ini = 1918.661 uV, v_off_fin = 1917.224 uV 15:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.542 uVs 15:46:27 Integrated Voltage Measurement... 15:46:36 Voltage Offset Correction: v_off_ini = 1922.924 uV, v_off_fin = 1939.506 uV 15:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.370 uVs 15:46:36 Integrated Voltage Measurement... 15:46:45 Voltage Offset Correction: v_off_ini = 1941.370 uV, v_off_fin = 1936.893 uV 15:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.954 uVs 15:46:45 Integrated Voltage Measurement... 15:46:54 Voltage Offset Correction: v_off_ini = 1934.404 uV, v_off_fin = 1936.092 uV 15:46:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.501 uVs 15:46:54 Integrated Voltage Measurement... 15:47:03 Voltage Offset Correction: v_off_ini = 1934.622 uV, v_off_fin = 1925.163 uV 15:47:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.097 uVs 15:47:06 I2Y Average and RMS of Measurements VT = -331.996 +- 2.607 uVs I2Y = -30.544 +- 0.240 uTm^2 15:47:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:24 Integrated Voltage Measurement... 15:47:33 Voltage Offset Correction: v_off_ini = 1930.685 uV, v_off_fin = 1938.472 uV 15:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -255.867 uVs 15:47:33 Integrated Voltage Measurement... 15:47:42 Voltage Offset Correction: v_off_ini = 1931.448 uV, v_off_fin = 1948.828 uV 15:47:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 280.349 uVs 15:47:42 Integrated Voltage Measurement... 15:47:51 Voltage Offset Correction: v_off_ini = 1936.871 uV, v_off_fin = 1934.512 uV 15:47:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -260.433 uVs 15:47:51 Integrated Voltage Measurement... 15:48:00 Voltage Offset Correction: v_off_ini = 1942.004 uV, v_off_fin = 1932.492 uV 15:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 266.178 uVs 15:48:00 Integrated Voltage Measurement... 15:48:09 Voltage Offset Correction: v_off_ini = 1937.694 uV, v_off_fin = 1932.938 uV 15:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -256.084 uVs 15:48:09 Integrated Voltage Measurement... 15:48:18 Voltage Offset Correction: v_off_ini = 1967.292 uV, v_off_fin = 1969.766 uV 15:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 255.444 uVs 15:48:22 I1X Average and RMS of Measurements VT = -262.393 +- 5.081 uVs I1X = 52.479 +- 1.016 uTm 15:48:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:29 Integrated Voltage Measurement... 15:48:38 Voltage Offset Correction: v_off_ini = 1961.302 uV, v_off_fin = 1953.445 uV 15:48:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.089 uVs 15:48:38 Integrated Voltage Measurement... 15:48:47 Voltage Offset Correction: v_off_ini = 1966.231 uV, v_off_fin = 1960.882 uV 15:48:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 271.993 uVs 15:48:47 Integrated Voltage Measurement... 15:48:56 Voltage Offset Correction: v_off_ini = 1943.097 uV, v_off_fin = 1933.697 uV 15:48:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -286.807 uVs 15:48:56 Integrated Voltage Measurement... 15:49:05 Voltage Offset Correction: v_off_ini = 1944.785 uV, v_off_fin = 1978.266 uV 15:49:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.224 uVs 15:49:05 Integrated Voltage Measurement... 15:49:14 Voltage Offset Correction: v_off_ini = 1960.204 uV, v_off_fin = 1949.309 uV 15:49:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.787 uVs 15:49:14 Integrated Voltage Measurement... 15:49:23 Voltage Offset Correction: v_off_ini = 1973.922 uV, v_off_fin = 1986.645 uV 15:49:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.768 uVs 15:49:27 I1Y Average and RMS of Measurements VT = -276.278 +- 2.813 uVs I1Y = -55.252 +- 0.562 uTm 15:49:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:35 Integrated Voltage Measurement... 15:49:44 Voltage Offset Correction: v_off_ini = 1966.935 uV, v_off_fin = 1942.882 uV 15:49:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -281.754 uVs 15:49:44 Integrated Voltage Measurement... 15:49:53 Voltage Offset Correction: v_off_ini = 1967.801 uV, v_off_fin = 1971.511 uV 15:49:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 250.222 uVs 15:49:53 Integrated Voltage Measurement... 15:50:02 Voltage Offset Correction: v_off_ini = 1954.454 uV, v_off_fin = 1930.513 uV 15:50:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -260.260 uVs 15:50:02 Integrated Voltage Measurement... 15:50:11 Voltage Offset Correction: v_off_ini = 1945.187 uV, v_off_fin = 1946.776 uV 15:50:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 304.535 uVs 15:50:11 Integrated Voltage Measurement... 15:50:20 Voltage Offset Correction: v_off_ini = 1951.475 uV, v_off_fin = 1940.014 uV 15:50:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -266.510 uVs 15:50:20 Integrated Voltage Measurement... 15:50:29 Voltage Offset Correction: v_off_ini = 1943.427 uV, v_off_fin = 1936.525 uV 15:50:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 277.127 uVs 15:50:31 I2X Average and RMS of Measurements VT = -273.401 +- 6.792 uVs I2X = 25.153 +- 0.625 uTm^2 15:50:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:39 Integrated Voltage Measurement... 15:50:48 Voltage Offset Correction: v_off_ini = 1932.416 uV, v_off_fin = 1926.365 uV 15:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.035 uVs 15:50:48 Integrated Voltage Measurement... 15:50:57 Voltage Offset Correction: v_off_ini = 1916.229 uV, v_off_fin = 1923.740 uV 15:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.949 uVs 15:50:57 Integrated Voltage Measurement... 15:51:06 Voltage Offset Correction: v_off_ini = 1918.405 uV, v_off_fin = 1916.909 uV 15:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.633 uVs 15:51:06 Integrated Voltage Measurement... 15:51:15 Voltage Offset Correction: v_off_ini = 1913.146 uV, v_off_fin = 1920.070 uV 15:51:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.684 uVs 15:51:15 Integrated Voltage Measurement... 15:51:24 Voltage Offset Correction: v_off_ini = 1909.498 uV, v_off_fin = 1899.818 uV 15:51:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.182 uVs 15:51:24 Integrated Voltage Measurement... 15:51:33 Voltage Offset Correction: v_off_ini = 1916.028 uV, v_off_fin = 1931.591 uV 15:51:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.057 uVs 15:51:36 I2Y Average and RMS of Measurements VT = -329.757 +- 0.687 uVs I2Y = -30.338 +- 0.063 uTm^2 15:51:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:54 Integrated Voltage Measurement... 15:52:03 Voltage Offset Correction: v_off_ini = 1912.802 uV, v_off_fin = 1901.082 uV 15:52:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -272.156 uVs 15:52:03 Integrated Voltage Measurement... 15:52:12 Voltage Offset Correction: v_off_ini = 1895.848 uV, v_off_fin = 1891.459 uV 15:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 248.895 uVs 15:52:12 Integrated Voltage Measurement... 15:52:21 Voltage Offset Correction: v_off_ini = 1915.155 uV, v_off_fin = 1906.083 uV 15:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -245.474 uVs 15:52:21 Integrated Voltage Measurement... 15:52:30 Voltage Offset Correction: v_off_ini = 1901.828 uV, v_off_fin = 1914.573 uV 15:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 229.079 uVs 15:52:30 Integrated Voltage Measurement... 15:52:39 Voltage Offset Correction: v_off_ini = 1916.734 uV, v_off_fin = 1907.752 uV 15:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -245.022 uVs 15:52:39 Integrated Voltage Measurement... 15:52:48 Voltage Offset Correction: v_off_ini = 1914.168 uV, v_off_fin = 1911.197 uV 15:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 237.889 uVs 15:52:52 I1X Average and RMS of Measurements VT = -246.419 +- 10.120 uVs I1X = 49.286 +- 2.026 uTm 15:52:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:59 Integrated Voltage Measurement... 15:53:08 Voltage Offset Correction: v_off_ini = 1897.701 uV, v_off_fin = 1894.302 uV 15:53:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -275.446 uVs 15:53:08 Integrated Voltage Measurement... 15:53:17 Voltage Offset Correction: v_off_ini = 1900.482 uV, v_off_fin = 1919.934 uV 15:53:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.615 uVs 15:53:17 Integrated Voltage Measurement... 15:53:26 Voltage Offset Correction: v_off_ini = 1887.004 uV, v_off_fin = 1893.734 uV 15:53:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.359 uVs 15:53:26 Integrated Voltage Measurement... 15:53:35 Voltage Offset Correction: v_off_ini = 1893.370 uV, v_off_fin = 1912.540 uV 15:53:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.506 uVs 15:53:35 Integrated Voltage Measurement... 15:53:44 Voltage Offset Correction: v_off_ini = 1924.742 uV, v_off_fin = 1915.416 uV 15:53:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -272.639 uVs 15:53:44 Integrated Voltage Measurement... 15:53:53 Voltage Offset Correction: v_off_ini = 1916.927 uV, v_off_fin = 1923.610 uV 15:53:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 283.830 uVs 15:53:57 I1Y Average and RMS of Measurements VT = -274.899 +- 3.580 uVs I1Y = -54.979 +- 0.715 uTm 15:54:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:05 Integrated Voltage Measurement... 15:54:14 Voltage Offset Correction: v_off_ini = 1912.517 uV, v_off_fin = 1900.369 uV 15:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -247.110 uVs 15:54:14 Integrated Voltage Measurement... 15:54:23 Voltage Offset Correction: v_off_ini = 1923.268 uV, v_off_fin = 1928.526 uV 15:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 253.978 uVs 15:54:23 Integrated Voltage Measurement... 15:54:32 Voltage Offset Correction: v_off_ini = 1921.460 uV, v_off_fin = 1928.401 uV 15:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -264.072 uVs 15:54:32 Integrated Voltage Measurement... 15:54:41 Voltage Offset Correction: v_off_ini = 1942.953 uV, v_off_fin = 1935.963 uV 15:54:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 248.118 uVs 15:54:41 Integrated Voltage Measurement... 15:54:50 Voltage Offset Correction: v_off_ini = 1948.313 uV, v_off_fin = 1928.928 uV 15:54:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -276.204 uVs 15:54:50 Integrated Voltage Measurement... 15:54:59 Voltage Offset Correction: v_off_ini = 1924.290 uV, v_off_fin = 1929.617 uV 15:54:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 264.114 uVs 15:55:01 I2X Average and RMS of Measurements VT = -258.933 +- 8.256 uVs I2X = 23.822 +- 0.760 uTm^2 15:55:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:09 Integrated Voltage Measurement... 15:55:18 Voltage Offset Correction: v_off_ini = 1940.609 uV, v_off_fin = 1914.231 uV 15:55:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.986 uVs 15:55:18 Integrated Voltage Measurement... 15:55:27 Voltage Offset Correction: v_off_ini = 1914.353 uV, v_off_fin = 1938.455 uV 15:55:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.042 uVs 15:55:27 Integrated Voltage Measurement... 15:55:36 Voltage Offset Correction: v_off_ini = 1937.727 uV, v_off_fin = 1900.499 uV 15:55:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.104 uVs 15:55:36 Integrated Voltage Measurement... 15:55:45 Voltage Offset Correction: v_off_ini = 1928.957 uV, v_off_fin = 1926.292 uV 15:55:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.286 uVs 15:55:45 Integrated Voltage Measurement... 15:55:54 Voltage Offset Correction: v_off_ini = 1926.415 uV, v_off_fin = 1927.580 uV 15:55:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.245 uVs 15:55:54 Integrated Voltage Measurement... 15:56:03 Voltage Offset Correction: v_off_ini = 1929.744 uV, v_off_fin = 1908.379 uV 15:56:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.768 uVs 15:56:05 I2Y Average and RMS of Measurements VT = -324.238 +- 6.577 uVs I2Y = -29.830 +- 0.605 uTm^2 15:56:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:23 Integrated Voltage Measurement... 15:56:32 Voltage Offset Correction: v_off_ini = 1972.012 uV, v_off_fin = 1973.527 uV 15:56:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -233.114 uVs 15:56:32 Integrated Voltage Measurement... 15:56:41 Voltage Offset Correction: v_off_ini = 1979.849 uV, v_off_fin = 1959.554 uV 15:56:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 242.677 uVs 15:56:41 Integrated Voltage Measurement... 15:56:50 Voltage Offset Correction: v_off_ini = 1962.594 uV, v_off_fin = 1950.073 uV 15:56:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -225.005 uVs 15:56:50 Integrated Voltage Measurement... 15:56:59 Voltage Offset Correction: v_off_ini = 1948.001 uV, v_off_fin = 1965.499 uV 15:56:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 237.479 uVs 15:56:59 Integrated Voltage Measurement... 15:57:08 Voltage Offset Correction: v_off_ini = 1955.683 uV, v_off_fin = 1954.439 uV 15:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -235.908 uVs 15:57:08 Integrated Voltage Measurement... 15:57:17 Voltage Offset Correction: v_off_ini = 1969.221 uV, v_off_fin = 1976.128 uV 15:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 248.125 uVs 15:57:22 I1X Average and RMS of Measurements VT = -237.051 +- 4.439 uVs I1X = 47.410 +- 0.888 uTm 15:57:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:28 Integrated Voltage Measurement... 15:57:37 Voltage Offset Correction: v_off_ini = 1972.240 uV, v_off_fin = 1959.352 uV 15:57:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -250.315 uVs 15:57:37 Integrated Voltage Measurement... 15:57:46 Voltage Offset Correction: v_off_ini = 1969.745 uV, v_off_fin = 2001.721 uV 15:57:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.289 uVs 15:57:46 Integrated Voltage Measurement... 15:57:55 Voltage Offset Correction: v_off_ini = 1985.707 uV, v_off_fin = 1954.015 uV 15:57:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -259.422 uVs 15:57:55 Integrated Voltage Measurement... 15:58:04 Voltage Offset Correction: v_off_ini = 1957.042 uV, v_off_fin = 1978.612 uV 15:58:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.417 uVs 15:58:04 Integrated Voltage Measurement... 15:58:13 Voltage Offset Correction: v_off_ini = 1965.156 uV, v_off_fin = 1951.184 uV 15:58:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -252.785 uVs 15:58:13 Integrated Voltage Measurement... 15:58:22 Voltage Offset Correction: v_off_ini = 1994.607 uV, v_off_fin = 2005.232 uV 15:58:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.496 uVs 15:58:26 I1Y Average and RMS of Measurements VT = -256.287 +- 2.114 uVs I1Y = -51.252 +- 0.423 uTm 15:58:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:34 Integrated Voltage Measurement... 15:58:43 Voltage Offset Correction: v_off_ini = 1974.868 uV, v_off_fin = 1982.584 uV 15:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -238.852 uVs 15:58:43 Integrated Voltage Measurement... 15:58:52 Voltage Offset Correction: v_off_ini = 1984.925 uV, v_off_fin = 1991.687 uV 15:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 211.836 uVs 15:58:52 Integrated Voltage Measurement... 15:59:01 Voltage Offset Correction: v_off_ini = 1975.117 uV, v_off_fin = 1980.818 uV 15:59:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -220.956 uVs 15:59:01 Integrated Voltage Measurement... 15:59:10 Voltage Offset Correction: v_off_ini = 1995.145 uV, v_off_fin = 2001.975 uV 15:59:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 228.538 uVs 15:59:10 Integrated Voltage Measurement... 15:59:19 Voltage Offset Correction: v_off_ini = 1996.184 uV, v_off_fin = 1997.397 uV 15:59:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -237.536 uVs 15:59:19 Integrated Voltage Measurement... 15:59:28 Voltage Offset Correction: v_off_ini = 1976.685 uV, v_off_fin = 2001.493 uV 15:59:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 239.696 uVs 15:59:31 I2X Average and RMS of Measurements VT = -229.569 +- 6.402 uVs I2X = 21.120 +- 0.589 uTm^2 15:59:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:38 Integrated Voltage Measurement... 15:59:47 Voltage Offset Correction: v_off_ini = 2016.258 uV, v_off_fin = 2022.780 uV 15:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.421 uVs 15:59:47 Integrated Voltage Measurement... 15:59:56 Voltage Offset Correction: v_off_ini = 2019.653 uV, v_off_fin = 2016.854 uV 15:59:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 298.988 uVs 15:59:56 Integrated Voltage Measurement... 16:00:05 Voltage Offset Correction: v_off_ini = 2009.674 uV, v_off_fin = 1997.225 uV 16:00:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.707 uVs 16:00:05 Integrated Voltage Measurement... 16:00:14 Voltage Offset Correction: v_off_ini = 2003.988 uV, v_off_fin = 2022.151 uV 16:00:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.578 uVs 16:00:14 Integrated Voltage Measurement... 16:00:23 Voltage Offset Correction: v_off_ini = 1988.715 uV, v_off_fin = 2015.273 uV 16:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.011 uVs 16:00:24 Integrated Voltage Measurement... 16:00:32 Voltage Offset Correction: v_off_ini = 2005.547 uV, v_off_fin = 2011.647 uV 16:00:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.329 uVs 16:00:35 I2Y Average and RMS of Measurements VT = -308.006 +- 5.323 uVs I2Y = -28.337 +- 0.490 uTm^2 16:00:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:53 Integrated Voltage Measurement... 16:01:02 Voltage Offset Correction: v_off_ini = 2026.865 uV, v_off_fin = 2038.772 uV 16:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.435 uVs 16:01:02 Integrated Voltage Measurement... 16:01:11 Voltage Offset Correction: v_off_ini = 2035.696 uV, v_off_fin = 2034.220 uV 16:01:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 233.042 uVs 16:01:11 Integrated Voltage Measurement... 16:01:20 Voltage Offset Correction: v_off_ini = 2044.452 uV, v_off_fin = 2026.406 uV 16:01:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -214.609 uVs 16:01:20 Integrated Voltage Measurement... 16:01:29 Voltage Offset Correction: v_off_ini = 2016.878 uV, v_off_fin = 2020.712 uV 16:01:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 206.801 uVs 16:01:29 Integrated Voltage Measurement... 16:01:38 Voltage Offset Correction: v_off_ini = 2023.831 uV, v_off_fin = 2040.128 uV 16:01:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -236.598 uVs 16:01:38 Integrated Voltage Measurement... 16:01:47 Voltage Offset Correction: v_off_ini = 2024.541 uV, v_off_fin = 2046.368 uV 16:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 222.467 uVs 16:01:52 I1X Average and RMS of Measurements VT = -217.159 +- 8.752 uVs I1X = 43.432 +- 1.750 uTm 16:01:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:58 Integrated Voltage Measurement... 16:02:07 Voltage Offset Correction: v_off_ini = 2028.993 uV, v_off_fin = 2016.925 uV 16:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.390 uVs 16:02:07 Integrated Voltage Measurement... 16:02:16 Voltage Offset Correction: v_off_ini = 2046.081 uV, v_off_fin = 2049.771 uV 16:02:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.692 uVs 16:02:16 Integrated Voltage Measurement... 16:02:25 Voltage Offset Correction: v_off_ini = 2033.645 uV, v_off_fin = 2027.450 uV 16:02:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.335 uVs 16:02:25 Integrated Voltage Measurement... 16:02:34 Voltage Offset Correction: v_off_ini = 2043.865 uV, v_off_fin = 2067.930 uV 16:02:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.148 uVs 16:02:34 Integrated Voltage Measurement... 16:02:43 Voltage Offset Correction: v_off_ini = 2035.682 uV, v_off_fin = 2022.588 uV 16:02:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.942 uVs 16:02:43 Integrated Voltage Measurement... 16:02:52 Voltage Offset Correction: v_off_ini = 2061.356 uV, v_off_fin = 2064.544 uV 16:02:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.411 uVs 16:02:56 I1Y Average and RMS of Measurements VT = -251.820 +- 8.216 uVs I1Y = -50.362 +- 1.644 uTm 16:03:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = 2047.175 uV, v_off_fin = 2031.359 uV 16:03:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -233.748 uVs 16:03:13 Integrated Voltage Measurement... 16:03:22 Voltage Offset Correction: v_off_ini = 2049.338 uV, v_off_fin = 2058.449 uV 16:03:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 234.010 uVs 16:03:22 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = 2054.197 uV, v_off_fin = 2041.289 uV 16:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -228.155 uVs 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = 2041.379 uV, v_off_fin = 2041.781 uV 16:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 218.998 uVs 16:03:40 Integrated Voltage Measurement... 16:03:49 Voltage Offset Correction: v_off_ini = 2049.469 uV, v_off_fin = 2060.466 uV 16:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -222.866 uVs 16:03:49 Integrated Voltage Measurement... 16:03:58 Voltage Offset Correction: v_off_ini = 2057.739 uV, v_off_fin = 2057.053 uV 16:03:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 235.236 uVs 16:04:01 I2X Average and RMS of Measurements VT = -228.835 +- 4.209 uVs I2X = 21.053 +- 0.387 uTm^2 16:04:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:08 Integrated Voltage Measurement... 16:04:17 Voltage Offset Correction: v_off_ini = 2049.115 uV, v_off_fin = 2049.115 uV 16:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.967 uVs 16:04:17 Integrated Voltage Measurement... 16:04:26 Voltage Offset Correction: v_off_ini = 2076.063 uV, v_off_fin = 2059.745 uV 16:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.977 uVs 16:04:26 Integrated Voltage Measurement... 16:04:35 Voltage Offset Correction: v_off_ini = 2040.362 uV, v_off_fin = 2042.791 uV 16:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.403 uVs 16:04:35 Integrated Voltage Measurement... 16:04:44 Voltage Offset Correction: v_off_ini = 2027.612 uV, v_off_fin = 2055.321 uV 16:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.438 uVs 16:04:44 Integrated Voltage Measurement... 16:04:53 Voltage Offset Correction: v_off_ini = 2067.422 uV, v_off_fin = 2065.044 uV 16:04:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.443 uVs 16:04:53 Integrated Voltage Measurement... 16:05:02 Voltage Offset Correction: v_off_ini = 2066.491 uV, v_off_fin = 2061.992 uV 16:05:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 293.089 uVs 16:05:05 I2Y Average and RMS of Measurements VT = -296.053 +- 5.463 uVs I2Y = -27.237 +- 0.503 uTm^2 16:05:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:23 Integrated Voltage Measurement... 16:05:32 Voltage Offset Correction: v_off_ini = 2067.407 uV, v_off_fin = 2052.725 uV 16:05:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.951 uVs 16:05:32 Integrated Voltage Measurement... 16:05:41 Voltage Offset Correction: v_off_ini = 2085.223 uV, v_off_fin = 2075.388 uV 16:05:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 200.279 uVs 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = 2058.397 uV, v_off_fin = 2054.821 uV 16:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -184.366 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 2058.986 uV, v_off_fin = 2064.407 uV 16:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 203.661 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = 2063.022 uV, v_off_fin = 2071.872 uV 16:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -184.549 uVs 16:06:08 Integrated Voltage Measurement... 16:06:17 Voltage Offset Correction: v_off_ini = 2080.609 uV, v_off_fin = 2067.552 uV 16:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 211.506 uVs 16:06:22 I1X Average and RMS of Measurements VT = -197.052 +- 2.194 uVs I1X = 39.410 +- 0.439 uTm 16:06:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:28 Integrated Voltage Measurement... 16:06:37 Voltage Offset Correction: v_off_ini = 2079.468 uV, v_off_fin = 2064.894 uV 16:06:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -256.295 uVs 16:06:37 Integrated Voltage Measurement... 16:06:46 Voltage Offset Correction: v_off_ini = 2081.176 uV, v_off_fin = 2083.659 uV 16:06:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.251 uVs 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = 2089.342 uV, v_off_fin = 2078.306 uV 16:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.854 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = 2077.895 uV, v_off_fin = 2100.853 uV 16:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.914 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 2062.097 uV, v_off_fin = 2068.477 uV 16:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.129 uVs 16:07:13 Integrated Voltage Measurement... 16:07:22 Voltage Offset Correction: v_off_ini = 2101.088 uV, v_off_fin = 2115.754 uV 16:07:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 239.585 uVs 16:07:26 I1Y Average and RMS of Measurements VT = -250.505 +- 3.918 uVs I1Y = -50.099 +- 0.784 uTm 16:07:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:34 Integrated Voltage Measurement... 16:07:43 Voltage Offset Correction: v_off_ini = 2077.520 uV, v_off_fin = 2081.757 uV 16:07:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -212.556 uVs 16:07:43 Integrated Voltage Measurement... 16:07:52 Voltage Offset Correction: v_off_ini = 2106.753 uV, v_off_fin = 2107.707 uV 16:07:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 214.100 uVs 16:07:52 Integrated Voltage Measurement... 16:08:01 Voltage Offset Correction: v_off_ini = 2084.158 uV, v_off_fin = 2063.934 uV 16:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -212.620 uVs 16:08:01 Integrated Voltage Measurement... 16:08:10 Voltage Offset Correction: v_off_ini = 2098.771 uV, v_off_fin = 2106.262 uV 16:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 203.679 uVs 16:08:10 Integrated Voltage Measurement... 16:08:19 Voltage Offset Correction: v_off_ini = 2077.856 uV, v_off_fin = 2061.144 uV 16:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -231.893 uVs 16:08:19 Integrated Voltage Measurement... 16:08:28 Voltage Offset Correction: v_off_ini = 2076.064 uV, v_off_fin = 2082.266 uV 16:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 201.797 uVs 16:08:31 I2X Average and RMS of Measurements VT = -212.774 +- 3.572 uVs I2X = 19.575 +- 0.329 uTm^2 16:08:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:38 Integrated Voltage Measurement... 16:08:47 Voltage Offset Correction: v_off_ini = 2046.303 uV, v_off_fin = 2039.787 uV 16:08:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -260.630 uVs 16:08:47 Integrated Voltage Measurement... 16:08:56 Voltage Offset Correction: v_off_ini = 2048.463 uV, v_off_fin = 2059.461 uV 16:08:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.714 uVs 16:08:56 Integrated Voltage Measurement... 16:09:05 Voltage Offset Correction: v_off_ini = 2084.529 uV, v_off_fin = 2079.186 uV 16:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.104 uVs 16:09:05 Integrated Voltage Measurement... 16:09:14 Voltage Offset Correction: v_off_ini = 2057.891 uV, v_off_fin = 2060.984 uV 16:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.415 uVs 16:09:14 Integrated Voltage Measurement... 16:09:23 Voltage Offset Correction: v_off_ini = 2061.578 uV, v_off_fin = 2059.758 uV 16:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.872 uVs 16:09:24 Integrated Voltage Measurement... 16:09:32 Voltage Offset Correction: v_off_ini = 2065.705 uV, v_off_fin = 2083.686 uV 16:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.740 uVs 16:09:35 I2Y Average and RMS of Measurements VT = -284.746 +- 9.247 uVs I2Y = -26.197 +- 0.850 uTm^2 16:09:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:53 Integrated Voltage Measurement... 16:10:02 Voltage Offset Correction: v_off_ini = 2078.837 uV, v_off_fin = 2064.679 uV 16:10:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -203.365 uVs 16:10:02 Integrated Voltage Measurement... 16:10:11 Voltage Offset Correction: v_off_ini = 2087.518 uV, v_off_fin = 2092.997 uV 16:10:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 198.433 uVs 16:10:11 Integrated Voltage Measurement... 16:10:20 Voltage Offset Correction: v_off_ini = 2095.843 uV, v_off_fin = 2094.050 uV 16:10:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -207.065 uVs 16:10:20 Integrated Voltage Measurement... 16:10:29 Voltage Offset Correction: v_off_ini = 2100.789 uV, v_off_fin = 2087.201 uV 16:10:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.766 uVs 16:10:29 Integrated Voltage Measurement... 16:10:38 Voltage Offset Correction: v_off_ini = 2105.945 uV, v_off_fin = 2097.802 uV 16:10:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -204.183 uVs 16:10:38 Integrated Voltage Measurement... 16:10:47 Voltage Offset Correction: v_off_ini = 2107.495 uV, v_off_fin = 2100.464 uV 16:10:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 206.828 uVs 16:10:51 I1X Average and RMS of Measurements VT = -202.273 +- 2.294 uVs I1X = 40.457 +- 0.460 uTm 16:10:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:58 Integrated Voltage Measurement... 16:11:07 Voltage Offset Correction: v_off_ini = 2111.406 uV, v_off_fin = 2089.403 uV 16:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.990 uVs 16:11:07 Integrated Voltage Measurement... 16:11:16 Voltage Offset Correction: v_off_ini = 2120.811 uV, v_off_fin = 2132.216 uV 16:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.595 uVs 16:11:16 Integrated Voltage Measurement... 16:11:25 Voltage Offset Correction: v_off_ini = 2104.905 uV, v_off_fin = 2113.281 uV 16:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.008 uVs 16:11:25 Integrated Voltage Measurement... 16:11:34 Voltage Offset Correction: v_off_ini = 2099.775 uV, v_off_fin = 2130.506 uV 16:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.720 uVs 16:11:34 Integrated Voltage Measurement... 16:11:43 Voltage Offset Correction: v_off_ini = 2122.020 uV, v_off_fin = 2094.591 uV 16:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.558 uVs 16:11:43 Integrated Voltage Measurement... 16:11:52 Voltage Offset Correction: v_off_ini = 2098.611 uV, v_off_fin = 2104.680 uV 16:11:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.162 uVs 16:11:56 I1Y Average and RMS of Measurements VT = -230.172 +- 10.176 uVs I1Y = -46.034 +- 2.036 uTm 16:12:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:04 Integrated Voltage Measurement... 16:12:13 Voltage Offset Correction: v_off_ini = 2078.367 uV, v_off_fin = 2079.651 uV 16:12:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -219.329 uVs 16:12:13 Integrated Voltage Measurement... 16:12:22 Voltage Offset Correction: v_off_ini = 2117.594 uV, v_off_fin = 2089.333 uV 16:12:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 221.873 uVs 16:12:22 Integrated Voltage Measurement... 16:12:31 Voltage Offset Correction: v_off_ini = 2114.028 uV, v_off_fin = 2099.278 uV 16:12:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -238.685 uVs 16:12:31 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = 2105.228 uV, v_off_fin = 2111.251 uV 16:12:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 220.199 uVs 16:12:40 Integrated Voltage Measurement... 16:12:49 Voltage Offset Correction: v_off_ini = 2096.859 uV, v_off_fin = 2092.292 uV 16:12:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -203.215 uVs 16:12:49 Integrated Voltage Measurement... 16:12:58 Voltage Offset Correction: v_off_ini = 2119.035 uV, v_off_fin = 2123.098 uV 16:12:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 209.240 uVs 16:13:01 I2X Average and RMS of Measurements VT = -218.757 +- 9.566 uVs I2X = 20.126 +- 0.880 uTm^2 16:13:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:08 Integrated Voltage Measurement... 16:13:17 Voltage Offset Correction: v_off_ini = 2110.612 uV, v_off_fin = 2112.051 uV 16:13:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.646 uVs 16:13:17 Integrated Voltage Measurement... 16:13:26 Voltage Offset Correction: v_off_ini = 2129.178 uV, v_off_fin = 2124.973 uV 16:13:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.718 uVs 16:13:26 Integrated Voltage Measurement... 16:13:35 Voltage Offset Correction: v_off_ini = 2123.107 uV, v_off_fin = 2105.234 uV 16:13:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.998 uVs 16:13:35 Integrated Voltage Measurement... 16:13:44 Voltage Offset Correction: v_off_ini = 2121.341 uV, v_off_fin = 2120.630 uV 16:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.320 uVs 16:13:44 Integrated Voltage Measurement... 16:13:53 Voltage Offset Correction: v_off_ini = 2126.387 uV, v_off_fin = 2124.029 uV 16:13:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.898 uVs 16:13:53 Integrated Voltage Measurement... 16:14:02 Voltage Offset Correction: v_off_ini = 2143.310 uV, v_off_fin = 2146.672 uV 16:14:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.719 uVs 16:14:05 I2Y Average and RMS of Measurements VT = -256.383 +- 4.103 uVs I2Y = -23.587 +- 0.377 uTm^2 16:14:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:05 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm