SLAC Magnetic Measurements Date: 08-12-2026 Time: 17:23:50 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: PS_DELTA-II Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 10 Measurement Device: Stretched Wire Operator: YL Comment: 17:23:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:00 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:24:01 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:24:03 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:24:04 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 17:24:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:20 Integrated Voltage Measurement... 17:24:29 Voltage Offset Correction: v_off_ini = 2675.873 uV, v_off_fin = 2666.742 uV 17:24:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.710 uVs 17:24:29 Integrated Voltage Measurement... 17:24:38 Voltage Offset Correction: v_off_ini = 2652.868 uV, v_off_fin = 2666.398 uV 17:24:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.786 uVs 17:24:38 Integrated Voltage Measurement... 17:24:47 Voltage Offset Correction: v_off_ini = 2662.366 uV, v_off_fin = 2652.977 uV 17:24:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.947 uVs 17:24:47 Integrated Voltage Measurement... 17:24:56 Voltage Offset Correction: v_off_ini = 2639.397 uV, v_off_fin = 2658.588 uV 17:24:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.948 uVs 17:24:56 Integrated Voltage Measurement... 17:25:05 Voltage Offset Correction: v_off_ini = 2655.140 uV, v_off_fin = 2645.248 uV 17:25:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.942 uVs 17:25:05 Integrated Voltage Measurement... 17:25:14 Voltage Offset Correction: v_off_ini = 2638.871 uV, v_off_fin = 2653.905 uV 17:25:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.405 uVs 17:25:18 I1X Average and RMS of Measurements VT = -76.290 +- 12.968 uVs I1X = 15.258 +- 2.594 uTm 17:25:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:25 Integrated Voltage Measurement... 17:25:34 Voltage Offset Correction: v_off_ini = 2622.230 uV, v_off_fin = 2606.008 uV 17:25:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.037 uVs 17:25:34 Integrated Voltage Measurement... 17:25:43 Voltage Offset Correction: v_off_ini = 2630.330 uV, v_off_fin = 2632.947 uV 17:25:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 176.832 uVs 17:25:43 Integrated Voltage Measurement... 17:25:52 Voltage Offset Correction: v_off_ini = 2650.560 uV, v_off_fin = 2634.640 uV 17:25:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -197.446 uVs 17:25:52 Integrated Voltage Measurement... 17:26:01 Voltage Offset Correction: v_off_ini = 2651.605 uV, v_off_fin = 2654.846 uV 17:26:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.403 uVs 17:26:01 Integrated Voltage Measurement... 17:26:10 Voltage Offset Correction: v_off_ini = 2629.055 uV, v_off_fin = 2624.568 uV 17:26:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.859 uVs 17:26:10 Integrated Voltage Measurement... 17:26:19 Voltage Offset Correction: v_off_ini = 2626.969 uV, v_off_fin = 2638.170 uV 17:26:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.474 uVs 17:26:23 I1Y Average and RMS of Measurements VT = -186.508 +- 3.093 uVs I1Y = -37.299 +- 0.618 uTm 17:26:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:31 Integrated Voltage Measurement... 17:26:39 Voltage Offset Correction: v_off_ini = 2612.215 uV, v_off_fin = 2616.441 uV 17:26:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.638 uVs 17:26:40 Integrated Voltage Measurement... 17:26:49 Voltage Offset Correction: v_off_ini = 2631.449 uV, v_off_fin = 2633.750 uV 17:26:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.054 uVs 17:26:49 Integrated Voltage Measurement... 17:26:58 Voltage Offset Correction: v_off_ini = 2609.132 uV, v_off_fin = 2584.556 uV 17:26:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.480 uVs 17:26:58 Integrated Voltage Measurement... 17:27:07 Voltage Offset Correction: v_off_ini = 2612.798 uV, v_off_fin = 2626.500 uV 17:27:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.237 uVs 17:27:07 Integrated Voltage Measurement... 17:27:16 Voltage Offset Correction: v_off_ini = 2630.224 uV, v_off_fin = 2622.385 uV 17:27:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.049 uVs 17:27:16 Integrated Voltage Measurement... 17:27:25 Voltage Offset Correction: v_off_ini = 2611.824 uV, v_off_fin = 2621.373 uV 17:27:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.759 uVs 17:27:27 I2X Average and RMS of Measurements VT = -83.869 +- 4.974 uVs I2X = 7.716 +- 0.458 uTm^2 17:27:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:35 Integrated Voltage Measurement... 17:27:44 Voltage Offset Correction: v_off_ini = 2608.963 uV, v_off_fin = 2597.942 uV 17:27:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -263.594 uVs 17:27:44 Integrated Voltage Measurement... 17:27:53 Voltage Offset Correction: v_off_ini = 2575.003 uV, v_off_fin = 2584.563 uV 17:27:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.531 uVs 17:27:53 Integrated Voltage Measurement... 17:28:02 Voltage Offset Correction: v_off_ini = 2596.831 uV, v_off_fin = 2579.767 uV 17:28:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.128 uVs 17:28:02 Integrated Voltage Measurement... 17:28:11 Voltage Offset Correction: v_off_ini = 2574.825 uV, v_off_fin = 2575.487 uV 17:28:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.685 uVs 17:28:11 Integrated Voltage Measurement... 17:28:20 Voltage Offset Correction: v_off_ini = 2546.708 uV, v_off_fin = 2550.171 uV 17:28:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.634 uVs 17:28:20 Integrated Voltage Measurement... 17:28:29 Voltage Offset Correction: v_off_ini = 2581.895 uV, v_off_fin = 2559.899 uV 17:28:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.325 uVs 17:28:31 I2Y Average and RMS of Measurements VT = -244.316 +- 7.587 uVs I2Y = -22.477 +- 0.698 uTm^2 17:28:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:46 Integrated Voltage Measurement... 17:28:55 Voltage Offset Correction: v_off_ini = 2544.823 uV, v_off_fin = 2538.813 uV 17:28:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -101.138 uVs 17:28:55 Integrated Voltage Measurement... 17:29:04 Voltage Offset Correction: v_off_ini = 2550.140 uV, v_off_fin = 2564.994 uV 17:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.434 uVs 17:29:04 Integrated Voltage Measurement... 17:29:13 Voltage Offset Correction: v_off_ini = 2549.444 uV, v_off_fin = 2537.006 uV 17:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.431 uVs 17:29:13 Integrated Voltage Measurement... 17:29:22 Voltage Offset Correction: v_off_ini = 2545.330 uV, v_off_fin = 2534.536 uV 17:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.243 uVs 17:29:22 Integrated Voltage Measurement... 17:29:31 Voltage Offset Correction: v_off_ini = 2547.085 uV, v_off_fin = 2526.091 uV 17:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.221 uVs 17:29:31 Integrated Voltage Measurement... 17:29:40 Voltage Offset Correction: v_off_ini = 2532.476 uV, v_off_fin = 2545.085 uV 17:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.212 uVs 17:29:44 I1X Average and RMS of Measurements VT = -81.113 +- 2.005 uVs I1X = 16.223 +- 0.400 uTm 17:29:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:51 Integrated Voltage Measurement... 17:30:00 Voltage Offset Correction: v_off_ini = 2534.414 uV, v_off_fin = 2522.255 uV 17:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.741 uVs 17:30:00 Integrated Voltage Measurement... 17:30:09 Voltage Offset Correction: v_off_ini = 2540.254 uV, v_off_fin = 2546.592 uV 17:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.680 uVs 17:30:09 Integrated Voltage Measurement... 17:30:18 Voltage Offset Correction: v_off_ini = 2523.649 uV, v_off_fin = 2546.363 uV 17:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.347 uVs 17:30:18 Integrated Voltage Measurement... 17:30:27 Voltage Offset Correction: v_off_ini = 2575.155 uV, v_off_fin = 2569.524 uV 17:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.449 uVs 17:30:27 Integrated Voltage Measurement... 17:30:36 Voltage Offset Correction: v_off_ini = 2549.611 uV, v_off_fin = 2538.311 uV 17:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.405 uVs 17:30:36 Integrated Voltage Measurement... 17:30:45 Voltage Offset Correction: v_off_ini = 2536.295 uV, v_off_fin = 2546.232 uV 17:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.200 uVs 17:30:49 I1Y Average and RMS of Measurements VT = -204.970 +- 2.073 uVs I1Y = -40.991 +- 0.414 uTm 17:30:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:57 Integrated Voltage Measurement... 17:31:06 Voltage Offset Correction: v_off_ini = 2548.623 uV, v_off_fin = 2528.919 uV 17:31:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -57.356 uVs 17:31:06 Integrated Voltage Measurement... 17:31:15 Voltage Offset Correction: v_off_ini = 2570.772 uV, v_off_fin = 2552.941 uV 17:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.607 uVs 17:31:15 Integrated Voltage Measurement... 17:31:24 Voltage Offset Correction: v_off_ini = 2543.212 uV, v_off_fin = 2532.737 uV 17:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.720 uVs 17:31:24 Integrated Voltage Measurement... 17:31:33 Voltage Offset Correction: v_off_ini = 2563.857 uV, v_off_fin = 2559.338 uV 17:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.793 uVs 17:31:33 Integrated Voltage Measurement... 17:31:42 Voltage Offset Correction: v_off_ini = 2538.449 uV, v_off_fin = 2525.709 uV 17:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.580 uVs 17:31:42 Integrated Voltage Measurement... 17:31:51 Voltage Offset Correction: v_off_ini = 2535.615 uV, v_off_fin = 2534.815 uV 17:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.165 uVs 17:31:53 I2X Average and RMS of Measurements VT = -75.537 +- 9.120 uVs I2X = 6.949 +- 0.839 uTm^2 17:31:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:32:01 Integrated Voltage Measurement... 17:32:10 Voltage Offset Correction: v_off_ini = 2527.326 uV, v_off_fin = 2552.770 uV 17:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.805 uVs 17:32:10 Integrated Voltage Measurement... 17:32:19 Voltage Offset Correction: v_off_ini = 2535.052 uV, v_off_fin = 2537.445 uV 17:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.482 uVs 17:32:19 Integrated Voltage Measurement... 17:32:28 Voltage Offset Correction: v_off_ini = 2535.853 uV, v_off_fin = 2543.835 uV 17:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.467 uVs 17:32:28 Integrated Voltage Measurement... 17:32:37 Voltage Offset Correction: v_off_ini = 2523.256 uV, v_off_fin = 2510.924 uV 17:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.982 uVs 17:32:37 Integrated Voltage Measurement... 17:32:46 Voltage Offset Correction: v_off_ini = 2527.941 uV, v_off_fin = 2516.905 uV 17:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.108 uVs 17:32:46 Integrated Voltage Measurement... 17:32:55 Voltage Offset Correction: v_off_ini = 2518.427 uV, v_off_fin = 2510.106 uV 17:32:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.753 uVs 17:32:58 I2Y Average and RMS of Measurements VT = -258.766 +- 10.367 uVs I2Y = -23.806 +- 0.954 uTm^2 17:33:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:13 Integrated Voltage Measurement... 17:33:22 Voltage Offset Correction: v_off_ini = 2531.187 uV, v_off_fin = 2537.096 uV 17:33:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.663 uVs 17:33:22 Integrated Voltage Measurement... 17:33:31 Voltage Offset Correction: v_off_ini = 2534.298 uV, v_off_fin = 2531.142 uV 17:33:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.158 uVs 17:33:31 Integrated Voltage Measurement... 17:33:40 Voltage Offset Correction: v_off_ini = 2529.287 uV, v_off_fin = 2538.283 uV 17:33:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.344 uVs 17:33:40 Integrated Voltage Measurement... 17:33:49 Voltage Offset Correction: v_off_ini = 2531.724 uV, v_off_fin = 2528.532 uV 17:33:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.628 uVs 17:33:49 Integrated Voltage Measurement... 17:33:58 Voltage Offset Correction: v_off_ini = 2531.193 uV, v_off_fin = 2516.803 uV 17:33:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.601 uVs 17:33:58 Integrated Voltage Measurement... 17:34:07 Voltage Offset Correction: v_off_ini = 2539.019 uV, v_off_fin = 2519.670 uV 17:34:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.455 uVs 17:34:11 I1X Average and RMS of Measurements VT = -88.142 +- 3.594 uVs I1X = 17.629 +- 0.719 uTm 17:34:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:18 Integrated Voltage Measurement... 17:34:27 Voltage Offset Correction: v_off_ini = 2524.287 uV, v_off_fin = 2526.133 uV 17:34:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.157 uVs 17:34:27 Integrated Voltage Measurement... 17:34:36 Voltage Offset Correction: v_off_ini = 2545.865 uV, v_off_fin = 2547.195 uV 17:34:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.412 uVs 17:34:36 Integrated Voltage Measurement... 17:34:45 Voltage Offset Correction: v_off_ini = 2558.717 uV, v_off_fin = 2554.438 uV 17:34:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.648 uVs 17:34:45 Integrated Voltage Measurement... 17:34:54 Voltage Offset Correction: v_off_ini = 2551.794 uV, v_off_fin = 2569.293 uV 17:34:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.944 uVs 17:34:54 Integrated Voltage Measurement... 17:35:03 Voltage Offset Correction: v_off_ini = 2571.960 uV, v_off_fin = 2574.696 uV 17:35:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.897 uVs 17:35:03 Integrated Voltage Measurement... 17:35:12 Voltage Offset Correction: v_off_ini = 2557.957 uV, v_off_fin = 2556.077 uV 17:35:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.832 uVs 17:35:16 I1Y Average and RMS of Measurements VT = -210.648 +- 1.246 uVs I1Y = -42.126 +- 0.248 uTm 17:35:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:23 Integrated Voltage Measurement... 17:35:32 Voltage Offset Correction: v_off_ini = 2533.787 uV, v_off_fin = 2541.162 uV 17:35:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -98.269 uVs 17:35:32 Integrated Voltage Measurement... 17:35:41 Voltage Offset Correction: v_off_ini = 2558.429 uV, v_off_fin = 2595.026 uV 17:35:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.324 uVs 17:35:42 Integrated Voltage Measurement... 17:35:50 Voltage Offset Correction: v_off_ini = 2572.336 uV, v_off_fin = 2561.650 uV 17:35:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.194 uVs 17:35:51 Integrated Voltage Measurement... 17:36:00 Voltage Offset Correction: v_off_ini = 2573.878 uV, v_off_fin = 2587.096 uV 17:36:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.334 uVs 17:36:00 Integrated Voltage Measurement... 17:36:09 Voltage Offset Correction: v_off_ini = 2594.364 uV, v_off_fin = 2552.516 uV 17:36:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.964 uVs 17:36:09 Integrated Voltage Measurement... 17:36:18 Voltage Offset Correction: v_off_ini = 2565.948 uV, v_off_fin = 2585.797 uV 17:36:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.005 uVs 17:36:20 I2X Average and RMS of Measurements VT = -101.515 +- 4.774 uVs I2X = 9.339 +- 0.439 uTm^2 17:36:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:36:28 Integrated Voltage Measurement... 17:36:37 Voltage Offset Correction: v_off_ini = 2565.022 uV, v_off_fin = 2527.106 uV 17:36:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.322 uVs 17:36:37 Integrated Voltage Measurement... 17:36:46 Voltage Offset Correction: v_off_ini = 2557.701 uV, v_off_fin = 2560.190 uV 17:36:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.705 uVs 17:36:46 Integrated Voltage Measurement... 17:36:55 Voltage Offset Correction: v_off_ini = 2553.845 uV, v_off_fin = 2557.410 uV 17:36:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.679 uVs 17:36:55 Integrated Voltage Measurement... 17:37:04 Voltage Offset Correction: v_off_ini = 2553.392 uV, v_off_fin = 2549.365 uV 17:37:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.262 uVs 17:37:04 Integrated Voltage Measurement... 17:37:13 Voltage Offset Correction: v_off_ini = 2533.168 uV, v_off_fin = 2550.712 uV 17:37:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.410 uVs 17:37:13 Integrated Voltage Measurement... 17:37:22 Voltage Offset Correction: v_off_ini = 2553.319 uV, v_off_fin = 2562.906 uV 17:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.169 uVs 17:37:24 I2Y Average and RMS of Measurements VT = -265.591 +- 2.564 uVs I2Y = -24.434 +- 0.236 uTm^2 17:37:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:37:39 Integrated Voltage Measurement... 17:37:48 Voltage Offset Correction: v_off_ini = 2576.414 uV, v_off_fin = 2577.551 uV 17:37:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.140 uVs 17:37:48 Integrated Voltage Measurement... 17:37:57 Voltage Offset Correction: v_off_ini = 2571.226 uV, v_off_fin = 2576.853 uV 17:37:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.048 uVs 17:37:57 Integrated Voltage Measurement... 17:38:06 Voltage Offset Correction: v_off_ini = 2570.555 uV, v_off_fin = 2571.528 uV 17:38:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.540 uVs 17:38:06 Integrated Voltage Measurement... 17:38:15 Voltage Offset Correction: v_off_ini = 2565.940 uV, v_off_fin = 2588.454 uV 17:38:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.717 uVs 17:38:15 Integrated Voltage Measurement... 17:38:24 Voltage Offset Correction: v_off_ini = 2569.983 uV, v_off_fin = 2582.932 uV 17:38:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.676 uVs 17:38:24 Integrated Voltage Measurement... 17:38:33 Voltage Offset Correction: v_off_ini = 2585.081 uV, v_off_fin = 2573.848 uV 17:38:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.690 uVs 17:38:37 I1X Average and RMS of Measurements VT = -109.802 +- 3.827 uVs I1X = 21.960 +- 0.765 uTm 17:38:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:44 Integrated Voltage Measurement... 17:38:53 Voltage Offset Correction: v_off_ini = 2575.064 uV, v_off_fin = 2566.253 uV 17:38:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.641 uVs 17:38:53 Integrated Voltage Measurement... 17:39:02 Voltage Offset Correction: v_off_ini = 2553.941 uV, v_off_fin = 2561.422 uV 17:39:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.586 uVs 17:39:02 Integrated Voltage Measurement... 17:39:11 Voltage Offset Correction: v_off_ini = 2568.202 uV, v_off_fin = 2546.328 uV 17:39:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.388 uVs 17:39:11 Integrated Voltage Measurement... 17:39:20 Voltage Offset Correction: v_off_ini = 2565.420 uV, v_off_fin = 2553.578 uV 17:39:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.074 uVs 17:39:20 Integrated Voltage Measurement... 17:39:29 Voltage Offset Correction: v_off_ini = 2527.746 uV, v_off_fin = 2506.896 uV 17:39:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.248 uVs 17:39:29 Integrated Voltage Measurement... 17:39:38 Voltage Offset Correction: v_off_ini = 2522.864 uV, v_off_fin = 2542.581 uV 17:39:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 204.125 uVs 17:39:42 I1Y Average and RMS of Measurements VT = -218.844 +- 6.252 uVs I1Y = -43.767 +- 1.248 uTm 17:39:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:50 Integrated Voltage Measurement... 17:39:59 Voltage Offset Correction: v_off_ini = 2515.692 uV, v_off_fin = 2494.978 uV 17:39:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.101 uVs 17:39:59 Integrated Voltage Measurement... 17:40:08 Voltage Offset Correction: v_off_ini = 2476.637 uV, v_off_fin = 2510.364 uV 17:40:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.389 uVs 17:40:08 Integrated Voltage Measurement... 17:40:17 Voltage Offset Correction: v_off_ini = 2501.340 uV, v_off_fin = 2489.880 uV 17:40:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.627 uVs 17:40:17 Integrated Voltage Measurement... 17:40:26 Voltage Offset Correction: v_off_ini = 2509.138 uV, v_off_fin = 2511.132 uV 17:40:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.621 uVs 17:40:26 Integrated Voltage Measurement... 17:40:35 Voltage Offset Correction: v_off_ini = 2499.894 uV, v_off_fin = 2497.231 uV 17:40:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.533 uVs 17:40:35 Integrated Voltage Measurement... 17:40:44 Voltage Offset Correction: v_off_ini = 2523.073 uV, v_off_fin = 2531.875 uV 17:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.309 uVs 17:40:47 I2X Average and RMS of Measurements VT = -111.763 +- 2.900 uVs I2X = 10.282 +- 0.267 uTm^2 17:40:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:54 Integrated Voltage Measurement... 17:41:03 Voltage Offset Correction: v_off_ini = 2523.000 uV, v_off_fin = 2533.499 uV 17:41:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.959 uVs 17:41:03 Integrated Voltage Measurement... 17:41:12 Voltage Offset Correction: v_off_ini = 2525.981 uV, v_off_fin = 2517.672 uV 17:41:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.883 uVs 17:41:12 Integrated Voltage Measurement... 17:41:21 Voltage Offset Correction: v_off_ini = 2522.395 uV, v_off_fin = 2540.473 uV 17:41:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.098 uVs 17:41:21 Integrated Voltage Measurement... 17:41:30 Voltage Offset Correction: v_off_ini = 2569.802 uV, v_off_fin = 2558.432 uV 17:41:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.793 uVs 17:41:30 Integrated Voltage Measurement... 17:41:39 Voltage Offset Correction: v_off_ini = 2537.337 uV, v_off_fin = 2534.695 uV 17:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.860 uVs 17:41:39 Integrated Voltage Measurement... 17:41:48 Voltage Offset Correction: v_off_ini = 2560.400 uV, v_off_fin = 2570.253 uV 17:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.656 uVs 17:41:51 I2Y Average and RMS of Measurements VT = -269.375 +- 8.622 uVs I2Y = -24.782 +- 0.793 uTm^2 17:42:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:06 Integrated Voltage Measurement... 17:42:15 Voltage Offset Correction: v_off_ini = 2544.903 uV, v_off_fin = 2552.961 uV 17:42:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.721 uVs 17:42:15 Integrated Voltage Measurement... 17:42:24 Voltage Offset Correction: v_off_ini = 2563.091 uV, v_off_fin = 2562.479 uV 17:42:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.088 uVs 17:42:24 Integrated Voltage Measurement... 17:42:33 Voltage Offset Correction: v_off_ini = 2559.146 uV, v_off_fin = 2580.886 uV 17:42:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.663 uVs 17:42:33 Integrated Voltage Measurement... 17:42:42 Voltage Offset Correction: v_off_ini = 2590.304 uV, v_off_fin = 2579.297 uV 17:42:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.841 uVs 17:42:42 Integrated Voltage Measurement... 17:42:51 Voltage Offset Correction: v_off_ini = 2581.873 uV, v_off_fin = 2589.180 uV 17:42:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.146 uVs 17:42:51 Integrated Voltage Measurement... 17:43:00 Voltage Offset Correction: v_off_ini = 2593.476 uV, v_off_fin = 2590.999 uV 17:43:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.093 uVs 17:43:04 I1X Average and RMS of Measurements VT = -118.259 +- 8.668 uVs I1X = 23.653 +- 1.732 uTm 17:43:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:11 Integrated Voltage Measurement... 17:43:20 Voltage Offset Correction: v_off_ini = 2561.330 uV, v_off_fin = 2547.721 uV 17:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.362 uVs 17:43:20 Integrated Voltage Measurement... 17:43:29 Voltage Offset Correction: v_off_ini = 2581.887 uV, v_off_fin = 2594.051 uV 17:43:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 252.325 uVs 17:43:29 Integrated Voltage Measurement... 17:43:38 Voltage Offset Correction: v_off_ini = 2565.086 uV, v_off_fin = 2548.737 uV 17:43:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.669 uVs 17:43:38 Integrated Voltage Measurement... 17:43:47 Voltage Offset Correction: v_off_ini = 2610.591 uV, v_off_fin = 2616.775 uV 17:43:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.582 uVs 17:43:47 Integrated Voltage Measurement... 17:43:56 Voltage Offset Correction: v_off_ini = 2592.435 uV, v_off_fin = 2568.695 uV 17:43:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.821 uVs 17:43:56 Integrated Voltage Measurement... 17:44:05 Voltage Offset Correction: v_off_ini = 2594.921 uV, v_off_fin = 2603.920 uV 17:44:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.379 uVs 17:44:09 I1Y Average and RMS of Measurements VT = -233.856 +- 7.088 uVs I1Y = -46.768 +- 1.416 uTm 17:44:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:17 Integrated Voltage Measurement... 17:44:26 Voltage Offset Correction: v_off_ini = 2600.830 uV, v_off_fin = 2603.539 uV 17:44:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.903 uVs 17:44:26 Integrated Voltage Measurement... 17:44:35 Voltage Offset Correction: v_off_ini = 2615.052 uV, v_off_fin = 2624.401 uV 17:44:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.947 uVs 17:44:35 Integrated Voltage Measurement... 17:44:44 Voltage Offset Correction: v_off_ini = 2600.924 uV, v_off_fin = 2621.520 uV 17:44:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.234 uVs 17:44:44 Integrated Voltage Measurement... 17:44:53 Voltage Offset Correction: v_off_ini = 2627.130 uV, v_off_fin = 2640.071 uV 17:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.341 uVs 17:44:53 Integrated Voltage Measurement... 17:45:02 Voltage Offset Correction: v_off_ini = 2632.786 uV, v_off_fin = 2615.331 uV 17:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.831 uVs 17:45:02 Integrated Voltage Measurement... 17:45:11 Voltage Offset Correction: v_off_ini = 2621.202 uV, v_off_fin = 2660.472 uV 17:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.538 uVs 17:45:13 I2X Average and RMS of Measurements VT = -134.966 +- 1.191 uVs I2X = 12.417 +- 0.109 uTm^2 17:45:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:21 Integrated Voltage Measurement... 17:45:30 Voltage Offset Correction: v_off_ini = 2632.555 uV, v_off_fin = 2625.092 uV 17:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.783 uVs 17:45:30 Integrated Voltage Measurement... 17:45:39 Voltage Offset Correction: v_off_ini = 2652.632 uV, v_off_fin = 2647.695 uV 17:45:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.575 uVs 17:45:39 Integrated Voltage Measurement... 17:45:48 Voltage Offset Correction: v_off_ini = 2661.716 uV, v_off_fin = 2655.941 uV 17:45:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.898 uVs 17:45:48 Integrated Voltage Measurement... 17:45:57 Voltage Offset Correction: v_off_ini = 2664.743 uV, v_off_fin = 2661.782 uV 17:45:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.360 uVs 17:45:57 Integrated Voltage Measurement... 17:46:06 Voltage Offset Correction: v_off_ini = 2659.497 uV, v_off_fin = 2657.070 uV 17:46:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.238 uVs 17:46:06 Integrated Voltage Measurement... 17:46:15 Voltage Offset Correction: v_off_ini = 2652.691 uV, v_off_fin = 2639.459 uV 17:46:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.401 uVs 17:46:17 I2Y Average and RMS of Measurements VT = -279.376 +- 5.011 uVs I2Y = -25.703 +- 0.461 uTm^2 17:46:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:32 Integrated Voltage Measurement... 17:46:41 Voltage Offset Correction: v_off_ini = 2655.869 uV, v_off_fin = 2638.196 uV 17:46:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.862 uVs 17:46:41 Integrated Voltage Measurement... 17:46:50 Voltage Offset Correction: v_off_ini = 2612.604 uV, v_off_fin = 2621.910 uV 17:46:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.983 uVs 17:46:50 Integrated Voltage Measurement... 17:46:59 Voltage Offset Correction: v_off_ini = 2650.331 uV, v_off_fin = 2642.117 uV 17:46:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.473 uVs 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 2627.413 uV, v_off_fin = 2635.449 uV 17:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.749 uVs 17:47:08 Integrated Voltage Measurement... 17:47:17 Voltage Offset Correction: v_off_ini = 2641.499 uV, v_off_fin = 2625.140 uV 17:47:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.699 uVs 17:47:17 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 2631.756 uV, v_off_fin = 2634.981 uV 17:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.761 uVs 17:47:31 I1X Average and RMS of Measurements VT = -133.254 +- 4.389 uVs I1X = 26.651 +- 0.877 uTm 17:47:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:47:37 Integrated Voltage Measurement... 17:47:46 Voltage Offset Correction: v_off_ini = 2603.257 uV, v_off_fin = 2612.389 uV 17:47:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -259.326 uVs 17:47:46 Integrated Voltage Measurement... 17:47:55 Voltage Offset Correction: v_off_ini = 2621.316 uV, v_off_fin = 2631.833 uV 17:47:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.071 uVs 17:47:55 Integrated Voltage Measurement... 17:48:04 Voltage Offset Correction: v_off_ini = 2614.112 uV, v_off_fin = 2613.820 uV 17:48:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.663 uVs 17:48:04 Integrated Voltage Measurement... 17:48:13 Voltage Offset Correction: v_off_ini = 2620.187 uV, v_off_fin = 2626.487 uV 17:48:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 234.979 uVs 17:48:13 Integrated Voltage Measurement... 17:48:22 Voltage Offset Correction: v_off_ini = 2595.074 uV, v_off_fin = 2604.497 uV 17:48:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.031 uVs 17:48:22 Integrated Voltage Measurement... 17:48:31 Voltage Offset Correction: v_off_ini = 2625.685 uV, v_off_fin = 2633.235 uV 17:48:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 242.659 uVs 17:48:35 I1Y Average and RMS of Measurements VT = -237.455 +- 6.336 uVs I1Y = -47.491 +- 1.266 uTm 17:48:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:48:43 Integrated Voltage Measurement... 17:48:52 Voltage Offset Correction: v_off_ini = 2587.709 uV, v_off_fin = 2598.835 uV 17:48:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.781 uVs 17:48:52 Integrated Voltage Measurement... 17:49:01 Voltage Offset Correction: v_off_ini = 2612.254 uV, v_off_fin = 2609.352 uV 17:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.939 uVs 17:49:01 Integrated Voltage Measurement... 17:49:10 Voltage Offset Correction: v_off_ini = 2618.470 uV, v_off_fin = 2602.208 uV 17:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.949 uVs 17:49:10 Integrated Voltage Measurement... 17:49:19 Voltage Offset Correction: v_off_ini = 2622.663 uV, v_off_fin = 2641.154 uV 17:49:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.804 uVs 17:49:19 Integrated Voltage Measurement... 17:49:28 Voltage Offset Correction: v_off_ini = 2622.543 uV, v_off_fin = 2617.587 uV 17:49:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.980 uVs 17:49:28 Integrated Voltage Measurement... 17:49:37 Voltage Offset Correction: v_off_ini = 2623.138 uV, v_off_fin = 2635.875 uV 17:49:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.202 uVs 17:49:40 I2X Average and RMS of Measurements VT = -133.442 +- 7.924 uVs I2X = 12.277 +- 0.729 uTm^2 17:49:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:49:47 Integrated Voltage Measurement... 17:49:56 Voltage Offset Correction: v_off_ini = 2635.939 uV, v_off_fin = 2635.924 uV 17:49:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.816 uVs 17:49:56 Integrated Voltage Measurement... 17:50:05 Voltage Offset Correction: v_off_ini = 2635.588 uV, v_off_fin = 2639.083 uV 17:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.472 uVs 17:50:05 Integrated Voltage Measurement... 17:50:14 Voltage Offset Correction: v_off_ini = 2612.155 uV, v_off_fin = 2613.249 uV 17:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.318 uVs 17:50:14 Integrated Voltage Measurement... 17:50:23 Voltage Offset Correction: v_off_ini = 2610.356 uV, v_off_fin = 2610.834 uV 17:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.354 uVs 17:50:23 Integrated Voltage Measurement... 17:50:32 Voltage Offset Correction: v_off_ini = 2631.652 uV, v_off_fin = 2624.131 uV 17:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.247 uVs 17:50:32 Integrated Voltage Measurement... 17:50:41 Voltage Offset Correction: v_off_ini = 2613.252 uV, v_off_fin = 2613.354 uV 17:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.262 uVs 17:50:44 I2Y Average and RMS of Measurements VT = -281.411 +- 2.829 uVs I2Y = -25.890 +- 0.260 uTm^2 17:50:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:59 Integrated Voltage Measurement... 17:51:08 Voltage Offset Correction: v_off_ini = 2621.009 uV, v_off_fin = 2602.649 uV 17:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.472 uVs 17:51:08 Integrated Voltage Measurement... 17:51:17 Voltage Offset Correction: v_off_ini = 2619.753 uV, v_off_fin = 2614.175 uV 17:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.152 uVs 17:51:17 Integrated Voltage Measurement... 17:51:26 Voltage Offset Correction: v_off_ini = 2600.967 uV, v_off_fin = 2590.815 uV 17:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.856 uVs 17:51:26 Integrated Voltage Measurement... 17:51:35 Voltage Offset Correction: v_off_ini = 2575.102 uV, v_off_fin = 2586.034 uV 17:51:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.525 uVs 17:51:35 Integrated Voltage Measurement... 17:51:44 Voltage Offset Correction: v_off_ini = 2594.968 uV, v_off_fin = 2584.925 uV 17:51:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.159 uVs 17:51:44 Integrated Voltage Measurement... 17:51:53 Voltage Offset Correction: v_off_ini = 2587.267 uV, v_off_fin = 2606.668 uV 17:51:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.298 uVs 17:51:57 I1X Average and RMS of Measurements VT = -135.244 +- 9.401 uVs I1X = 27.049 +- 1.880 uTm 17:52:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:52:04 Integrated Voltage Measurement... 17:52:13 Voltage Offset Correction: v_off_ini = 2593.342 uV, v_off_fin = 2572.209 uV 17:52:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.757 uVs 17:52:13 Integrated Voltage Measurement... 17:52:22 Voltage Offset Correction: v_off_ini = 2592.818 uV, v_off_fin = 2601.726 uV 17:52:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.262 uVs 17:52:22 Integrated Voltage Measurement... 17:52:31 Voltage Offset Correction: v_off_ini = 2579.601 uV, v_off_fin = 2575.221 uV 17:52:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -243.532 uVs 17:52:31 Integrated Voltage Measurement... 17:52:40 Voltage Offset Correction: v_off_ini = 2572.582 uV, v_off_fin = 2596.317 uV 17:52:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.054 uVs 17:52:40 Integrated Voltage Measurement... 17:52:49 Voltage Offset Correction: v_off_ini = 2593.631 uV, v_off_fin = 2575.094 uV 17:52:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.742 uVs 17:52:49 Integrated Voltage Measurement... 17:52:58 Voltage Offset Correction: v_off_ini = 2599.328 uV, v_off_fin = 2606.966 uV 17:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 240.359 uVs 17:53:02 I1Y Average and RMS of Measurements VT = -246.784 +- 3.349 uVs I1Y = -49.356 +- 0.668 uTm 17:53:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:53:10 Integrated Voltage Measurement... 17:53:19 Voltage Offset Correction: v_off_ini = 2578.131 uV, v_off_fin = 2573.727 uV 17:53:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -149.804 uVs 17:53:19 Integrated Voltage Measurement... 17:53:28 Voltage Offset Correction: v_off_ini = 2569.683 uV, v_off_fin = 2572.769 uV 17:53:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.646 uVs 17:53:28 Integrated Voltage Measurement... 17:53:37 Voltage Offset Correction: v_off_ini = 2582.633 uV, v_off_fin = 2558.463 uV 17:53:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.091 uVs 17:53:37 Integrated Voltage Measurement... 17:53:46 Voltage Offset Correction: v_off_ini = 2549.014 uV, v_off_fin = 2554.293 uV 17:53:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.612 uVs 17:53:46 Integrated Voltage Measurement... 17:53:55 Voltage Offset Correction: v_off_ini = 2545.801 uV, v_off_fin = 2520.526 uV 17:53:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.280 uVs 17:53:55 Integrated Voltage Measurement... 17:54:04 Voltage Offset Correction: v_off_ini = 2525.313 uV, v_off_fin = 2527.401 uV 17:54:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.512 uVs 17:54:06 I2X Average and RMS of Measurements VT = -147.158 +- 4.907 uVs I2X = 13.538 +- 0.452 uTm^2 17:54:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:54:14 Integrated Voltage Measurement... 17:54:23 Voltage Offset Correction: v_off_ini = 2528.268 uV, v_off_fin = 2513.001 uV 17:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.597 uVs 17:54:23 Integrated Voltage Measurement... 17:54:32 Voltage Offset Correction: v_off_ini = 2528.932 uV, v_off_fin = 2517.844 uV 17:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 305.244 uVs 17:54:32 Integrated Voltage Measurement... 17:54:41 Voltage Offset Correction: v_off_ini = 2539.376 uV, v_off_fin = 2538.017 uV 17:54:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.962 uVs 17:54:41 Integrated Voltage Measurement... 17:54:50 Voltage Offset Correction: v_off_ini = 2529.820 uV, v_off_fin = 2530.540 uV 17:54:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.335 uVs 17:54:50 Integrated Voltage Measurement... 17:54:59 Voltage Offset Correction: v_off_ini = 2536.465 uV, v_off_fin = 2529.097 uV 17:54:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.772 uVs 17:54:59 Integrated Voltage Measurement... 17:55:08 Voltage Offset Correction: v_off_ini = 2541.079 uV, v_off_fin = 2544.026 uV 17:55:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 298.507 uVs 17:55:10 I2Y Average and RMS of Measurements VT = -299.569 +- 6.082 uVs I2Y = -27.560 +- 0.560 uTm^2 17:55:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:55:25 Integrated Voltage Measurement... 17:55:34 Voltage Offset Correction: v_off_ini = 2509.958 uV, v_off_fin = 2498.071 uV 17:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -170.086 uVs 17:55:34 Integrated Voltage Measurement... 17:55:43 Voltage Offset Correction: v_off_ini = 2494.139 uV, v_off_fin = 2495.280 uV 17:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.455 uVs 17:55:43 Integrated Voltage Measurement... 17:55:52 Voltage Offset Correction: v_off_ini = 2477.528 uV, v_off_fin = 2488.475 uV 17:55:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.203 uVs 17:55:52 Integrated Voltage Measurement... 17:56:01 Voltage Offset Correction: v_off_ini = 2490.389 uV, v_off_fin = 2504.688 uV 17:56:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.670 uVs 17:56:01 Integrated Voltage Measurement... 17:56:10 Voltage Offset Correction: v_off_ini = 2498.834 uV, v_off_fin = 2483.521 uV 17:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.858 uVs 17:56:10 Integrated Voltage Measurement... 17:56:19 Voltage Offset Correction: v_off_ini = 2487.712 uV, v_off_fin = 2507.430 uV 17:56:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.667 uVs 17:56:24 I1X Average and RMS of Measurements VT = -147.490 +- 5.586 uVs I1X = 29.499 +- 1.118 uTm 17:56:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:56:30 Integrated Voltage Measurement... 17:56:39 Voltage Offset Correction: v_off_ini = 2527.381 uV, v_off_fin = 2510.356 uV 17:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.754 uVs 17:56:39 Integrated Voltage Measurement... 17:56:48 Voltage Offset Correction: v_off_ini = 2519.592 uV, v_off_fin = 2535.610 uV 17:56:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.457 uVs 17:56:48 Integrated Voltage Measurement... 17:56:57 Voltage Offset Correction: v_off_ini = 2517.599 uV, v_off_fin = 2511.132 uV 17:56:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.769 uVs 17:56:57 Integrated Voltage Measurement... 17:57:06 Voltage Offset Correction: v_off_ini = 2497.975 uV, v_off_fin = 2506.785 uV 17:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 260.396 uVs 17:57:06 Integrated Voltage Measurement... 17:57:15 Voltage Offset Correction: v_off_ini = 2521.432 uV, v_off_fin = 2494.514 uV 17:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.987 uVs 17:57:15 Integrated Voltage Measurement... 17:57:24 Voltage Offset Correction: v_off_ini = 2533.055 uV, v_off_fin = 2534.837 uV 17:57:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 234.845 uVs 17:57:29 I1Y Average and RMS of Measurements VT = -249.368 +- 6.825 uVs I1Y = -49.874 +- 1.365 uTm 17:57:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:57:36 Integrated Voltage Measurement... 17:57:45 Voltage Offset Correction: v_off_ini = 2528.752 uV, v_off_fin = 2527.775 uV 17:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.239 uVs 17:57:45 Integrated Voltage Measurement... 17:57:54 Voltage Offset Correction: v_off_ini = 2523.565 uV, v_off_fin = 2543.701 uV 17:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.737 uVs 17:57:54 Integrated Voltage Measurement... 17:58:03 Voltage Offset Correction: v_off_ini = 2513.308 uV, v_off_fin = 2518.002 uV 17:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.590 uVs 17:58:03 Integrated Voltage Measurement... 17:58:12 Voltage Offset Correction: v_off_ini = 2538.524 uV, v_off_fin = 2534.945 uV 17:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.218 uVs 17:58:12 Integrated Voltage Measurement... 17:58:21 Voltage Offset Correction: v_off_ini = 2531.013 uV, v_off_fin = 2532.360 uV 17:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.301 uVs 17:58:21 Integrated Voltage Measurement... 17:58:30 Voltage Offset Correction: v_off_ini = 2545.624 uV, v_off_fin = 2567.231 uV 17:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 158.205 uVs 17:58:33 I2X Average and RMS of Measurements VT = -155.715 +- 8.906 uVs I2X = 14.326 +- 0.819 uTm^2 17:58:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:58:41 Integrated Voltage Measurement... 17:58:50 Voltage Offset Correction: v_off_ini = 2526.094 uV, v_off_fin = 2536.054 uV 17:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.198 uVs 17:58:50 Integrated Voltage Measurement... 17:58:59 Voltage Offset Correction: v_off_ini = 2509.229 uV, v_off_fin = 2525.679 uV 17:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.784 uVs 17:58:59 Integrated Voltage Measurement... 17:59:08 Voltage Offset Correction: v_off_ini = 2518.731 uV, v_off_fin = 2531.666 uV 17:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.977 uVs 17:59:08 Integrated Voltage Measurement... 17:59:17 Voltage Offset Correction: v_off_ini = 2523.001 uV, v_off_fin = 2525.482 uV 17:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.217 uVs 17:59:17 Integrated Voltage Measurement... 17:59:26 Voltage Offset Correction: v_off_ini = 2484.943 uV, v_off_fin = 2507.832 uV 17:59:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.545 uVs 17:59:26 Integrated Voltage Measurement... 17:59:35 Voltage Offset Correction: v_off_ini = 2526.371 uV, v_off_fin = 2533.799 uV 17:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.475 uVs 17:59:37 I2Y Average and RMS of Measurements VT = -303.366 +- 10.827 uVs I2Y = -27.910 +- 0.996 uTm^2 17:59:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:59:52 Integrated Voltage Measurement... 18:00:01 Voltage Offset Correction: v_off_ini = 2516.180 uV, v_off_fin = 2516.297 uV 18:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.960 uVs 18:00:01 Integrated Voltage Measurement... 18:00:10 Voltage Offset Correction: v_off_ini = 2507.222 uV, v_off_fin = 2525.164 uV 18:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.446 uVs 18:00:10 Integrated Voltage Measurement... 18:00:19 Voltage Offset Correction: v_off_ini = 2511.807 uV, v_off_fin = 2519.982 uV 18:00:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.794 uVs 18:00:19 Integrated Voltage Measurement... 18:00:28 Voltage Offset Correction: v_off_ini = 2514.569 uV, v_off_fin = 2519.437 uV 18:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.492 uVs 18:00:28 Integrated Voltage Measurement... 18:00:37 Voltage Offset Correction: v_off_ini = 2525.311 uV, v_off_fin = 2525.024 uV 18:00:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.039 uVs 18:00:37 Integrated Voltage Measurement... 18:00:46 Voltage Offset Correction: v_off_ini = 2547.179 uV, v_off_fin = 2528.335 uV 18:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.856 uVs 18:00:50 I1X Average and RMS of Measurements VT = -152.764 +- 2.687 uVs I1X = 30.553 +- 0.537 uTm 18:00:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:00:57 Integrated Voltage Measurement... 18:01:06 Voltage Offset Correction: v_off_ini = 2498.662 uV, v_off_fin = 2488.308 uV 18:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.108 uVs 18:01:06 Integrated Voltage Measurement... 18:01:15 Voltage Offset Correction: v_off_ini = 2505.403 uV, v_off_fin = 2522.320 uV 18:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 244.105 uVs 18:01:15 Integrated Voltage Measurement... 18:01:24 Voltage Offset Correction: v_off_ini = 2530.753 uV, v_off_fin = 2501.394 uV 18:01:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.130 uVs 18:01:24 Integrated Voltage Measurement... 18:01:33 Voltage Offset Correction: v_off_ini = 2523.004 uV, v_off_fin = 2540.400 uV 18:01:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.878 uVs 18:01:33 Integrated Voltage Measurement... 18:01:42 Voltage Offset Correction: v_off_ini = 2542.333 uV, v_off_fin = 2522.470 uV 18:01:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -259.787 uVs 18:01:42 Integrated Voltage Measurement... 18:01:51 Voltage Offset Correction: v_off_ini = 2526.058 uV, v_off_fin = 2545.703 uV 18:01:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.959 uVs 18:01:55 I1Y Average and RMS of Measurements VT = -254.161 +- 7.723 uVs I1Y = -50.830 +- 1.541 uTm 18:02:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:03 Integrated Voltage Measurement... 18:02:12 Voltage Offset Correction: v_off_ini = 2508.663 uV, v_off_fin = 2528.105 uV 18:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.873 uVs 18:02:12 Integrated Voltage Measurement... 18:02:21 Voltage Offset Correction: v_off_ini = 2516.503 uV, v_off_fin = 2517.256 uV 18:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 177.873 uVs 18:02:21 Integrated Voltage Measurement... 18:02:30 Voltage Offset Correction: v_off_ini = 2509.265 uV, v_off_fin = 2493.826 uV 18:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.222 uVs 18:02:30 Integrated Voltage Measurement... 18:02:39 Voltage Offset Correction: v_off_ini = 2489.158 uV, v_off_fin = 2523.365 uV 18:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 182.060 uVs 18:02:39 Integrated Voltage Measurement... 18:02:48 Voltage Offset Correction: v_off_ini = 2510.135 uV, v_off_fin = 2491.938 uV 18:02:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -173.210 uVs 18:02:48 Integrated Voltage Measurement... 18:02:57 Voltage Offset Correction: v_off_ini = 2510.095 uV, v_off_fin = 2509.127 uV 18:02:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 170.987 uVs 18:03:00 I2X Average and RMS of Measurements VT = -176.204 +- 3.378 uVs I2X = 16.211 +- 0.311 uTm^2 18:03:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:07 Integrated Voltage Measurement... 18:03:16 Voltage Offset Correction: v_off_ini = 2519.733 uV, v_off_fin = 2512.346 uV 18:03:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.133 uVs 18:03:16 Integrated Voltage Measurement... 18:03:25 Voltage Offset Correction: v_off_ini = 2494.880 uV, v_off_fin = 2499.026 uV 18:03:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.580 uVs 18:03:25 Integrated Voltage Measurement... 18:03:34 Voltage Offset Correction: v_off_ini = 2484.308 uV, v_off_fin = 2489.206 uV 18:03:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.342 uVs 18:03:34 Integrated Voltage Measurement... 18:03:43 Voltage Offset Correction: v_off_ini = 2479.400 uV, v_off_fin = 2501.729 uV 18:03:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.216 uVs 18:03:43 Integrated Voltage Measurement... 18:03:52 Voltage Offset Correction: v_off_ini = 2505.116 uV, v_off_fin = 2503.152 uV 18:03:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.489 uVs 18:03:52 Integrated Voltage Measurement... 18:04:01 Voltage Offset Correction: v_off_ini = 2494.456 uV, v_off_fin = 2506.097 uV 18:04:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.332 uVs 18:04:04 I2Y Average and RMS of Measurements VT = -308.682 +- 7.977 uVs I2Y = -28.399 +- 0.734 uTm^2 18:04:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:04:19 Integrated Voltage Measurement... 18:04:28 Voltage Offset Correction: v_off_ini = 2492.042 uV, v_off_fin = 2473.334 uV 18:04:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.690 uVs 18:04:28 Integrated Voltage Measurement... 18:04:37 Voltage Offset Correction: v_off_ini = 2494.554 uV, v_off_fin = 2501.736 uV 18:04:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.952 uVs 18:04:37 Integrated Voltage Measurement... 18:04:46 Voltage Offset Correction: v_off_ini = 2488.652 uV, v_off_fin = 2463.313 uV 18:04:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.469 uVs 18:04:46 Integrated Voltage Measurement... 18:04:55 Voltage Offset Correction: v_off_ini = 2452.133 uV, v_off_fin = 2466.387 uV 18:04:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.180 uVs 18:04:55 Integrated Voltage Measurement... 18:05:04 Voltage Offset Correction: v_off_ini = 2476.687 uV, v_off_fin = 2489.887 uV 18:05:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -191.031 uVs 18:05:04 Integrated Voltage Measurement... 18:05:13 Voltage Offset Correction: v_off_ini = 2477.395 uV, v_off_fin = 2486.203 uV 18:05:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.042 uVs 18:05:17 I1X Average and RMS of Measurements VT = -156.061 +- 10.244 uVs I1X = 31.214 +- 2.049 uTm 18:05:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:05:24 Integrated Voltage Measurement... 18:05:33 Voltage Offset Correction: v_off_ini = 2489.851 uV, v_off_fin = 2475.515 uV 18:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.998 uVs 18:05:33 Integrated Voltage Measurement... 18:05:42 Voltage Offset Correction: v_off_ini = 2494.837 uV, v_off_fin = 2501.928 uV 18:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.684 uVs 18:05:42 Integrated Voltage Measurement... 18:05:51 Voltage Offset Correction: v_off_ini = 2491.092 uV, v_off_fin = 2472.673 uV 18:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.099 uVs 18:05:51 Integrated Voltage Measurement... 18:06:00 Voltage Offset Correction: v_off_ini = 2499.999 uV, v_off_fin = 2486.026 uV 18:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 231.280 uVs 18:06:00 Integrated Voltage Measurement... 18:06:09 Voltage Offset Correction: v_off_ini = 2465.087 uV, v_off_fin = 2439.849 uV 18:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -247.537 uVs 18:06:09 Integrated Voltage Measurement... 18:06:18 Voltage Offset Correction: v_off_ini = 2468.838 uV, v_off_fin = 2472.800 uV 18:06:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.495 uVs 18:06:22 I1Y Average and RMS of Measurements VT = -253.515 +- 4.566 uVs I1Y = -50.702 +- 0.911 uTm 18:06:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:30 Integrated Voltage Measurement... 18:06:39 Voltage Offset Correction: v_off_ini = 2475.739 uV, v_off_fin = 2466.530 uV 18:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -175.256 uVs 18:06:39 Integrated Voltage Measurement... 18:06:48 Voltage Offset Correction: v_off_ini = 2478.066 uV, v_off_fin = 2489.778 uV 18:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 188.695 uVs 18:06:48 Integrated Voltage Measurement... 18:06:57 Voltage Offset Correction: v_off_ini = 2457.979 uV, v_off_fin = 2446.709 uV 18:06:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -191.702 uVs 18:06:57 Integrated Voltage Measurement... 18:07:06 Voltage Offset Correction: v_off_ini = 2494.363 uV, v_off_fin = 2499.358 uV 18:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 182.305 uVs 18:07:06 Integrated Voltage Measurement... 18:07:15 Voltage Offset Correction: v_off_ini = 2481.440 uV, v_off_fin = 2473.062 uV 18:07:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.614 uVs 18:07:15 Integrated Voltage Measurement... 18:07:24 Voltage Offset Correction: v_off_ini = 2470.765 uV, v_off_fin = 2499.512 uV 18:07:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 172.685 uVs 18:07:26 I2X Average and RMS of Measurements VT = -180.209 +- 6.391 uVs I2X = 16.579 +- 0.588 uTm^2 18:07:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:34 Integrated Voltage Measurement... 18:07:43 Voltage Offset Correction: v_off_ini = 2483.492 uV, v_off_fin = 2472.459 uV 18:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.273 uVs 18:07:43 Integrated Voltage Measurement... 18:07:52 Voltage Offset Correction: v_off_ini = 2473.291 uV, v_off_fin = 2463.142 uV 18:07:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.963 uVs 18:07:52 Integrated Voltage Measurement... 18:08:01 Voltage Offset Correction: v_off_ini = 2472.692 uV, v_off_fin = 2489.667 uV 18:08:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.353 uVs 18:08:01 Integrated Voltage Measurement... 18:08:10 Voltage Offset Correction: v_off_ini = 2470.607 uV, v_off_fin = 2473.323 uV 18:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.534 uVs 18:08:10 Integrated Voltage Measurement... 18:08:19 Voltage Offset Correction: v_off_ini = 2469.297 uV, v_off_fin = 2465.361 uV 18:08:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.671 uVs 18:08:19 Integrated Voltage Measurement... 18:08:28 Voltage Offset Correction: v_off_ini = 2474.714 uV, v_off_fin = 2463.834 uV 18:08:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.589 uVs 18:08:30 I2Y Average and RMS of Measurements VT = -312.231 +- 2.397 uVs I2Y = -28.725 +- 0.220 uTm^2 18:08:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:08:45 Integrated Voltage Measurement... 18:08:54 Voltage Offset Correction: v_off_ini = 2459.869 uV, v_off_fin = 2462.483 uV 18:08:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -178.203 uVs 18:08:54 Integrated Voltage Measurement... 18:09:03 Voltage Offset Correction: v_off_ini = 2474.642 uV, v_off_fin = 2487.680 uV 18:09:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.202 uVs 18:09:03 Integrated Voltage Measurement... 18:09:12 Voltage Offset Correction: v_off_ini = 2469.162 uV, v_off_fin = 2462.820 uV 18:09:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -182.763 uVs 18:09:12 Integrated Voltage Measurement... 18:09:21 Voltage Offset Correction: v_off_ini = 2453.653 uV, v_off_fin = 2452.582 uV 18:09:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.190 uVs 18:09:21 Integrated Voltage Measurement... 18:09:30 Voltage Offset Correction: v_off_ini = 2449.135 uV, v_off_fin = 2450.987 uV 18:09:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.433 uVs 18:09:30 Integrated Voltage Measurement... 18:09:39 Voltage Offset Correction: v_off_ini = 2472.654 uV, v_off_fin = 2474.744 uV 18:09:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 179.769 uVs 18:09:44 I1X Average and RMS of Measurements VT = -171.760 +- 5.142 uVs I1X = 34.353 +- 1.027 uTm 18:09:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:09:50 Integrated Voltage Measurement... 18:09:59 Voltage Offset Correction: v_off_ini = 2458.069 uV, v_off_fin = 2454.461 uV 18:09:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.566 uVs 18:09:59 Integrated Voltage Measurement... 18:10:08 Voltage Offset Correction: v_off_ini = 2467.848 uV, v_off_fin = 2490.585 uV 18:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 267.955 uVs 18:10:08 Integrated Voltage Measurement... 18:10:17 Voltage Offset Correction: v_off_ini = 2487.754 uV, v_off_fin = 2474.312 uV 18:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.667 uVs 18:10:17 Integrated Voltage Measurement... 18:10:26 Voltage Offset Correction: v_off_ini = 2485.504 uV, v_off_fin = 2482.042 uV 18:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.233 uVs 18:10:26 Integrated Voltage Measurement... 18:10:35 Voltage Offset Correction: v_off_ini = 2479.136 uV, v_off_fin = 2460.027 uV 18:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.151 uVs 18:10:35 Integrated Voltage Measurement... 18:10:44 Voltage Offset Correction: v_off_ini = 2481.312 uV, v_off_fin = 2487.821 uV 18:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 261.998 uVs 18:10:49 I1Y Average and RMS of Measurements VT = -257.095 +- 1.553 uVs I1Y = -51.416 +- 0.309 uTm 18:10:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:10:56 Integrated Voltage Measurement... 18:11:05 Voltage Offset Correction: v_off_ini = 2466.495 uV, v_off_fin = 2474.264 uV 18:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -180.627 uVs 18:11:05 Integrated Voltage Measurement... 18:11:14 Voltage Offset Correction: v_off_ini = 2459.956 uV, v_off_fin = 2471.047 uV 18:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 190.922 uVs 18:11:14 Integrated Voltage Measurement... 18:11:23 Voltage Offset Correction: v_off_ini = 2485.683 uV, v_off_fin = 2481.173 uV 18:11:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -202.423 uVs 18:11:23 Integrated Voltage Measurement... 18:11:32 Voltage Offset Correction: v_off_ini = 2489.038 uV, v_off_fin = 2504.991 uV 18:11:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 177.466 uVs 18:11:32 Integrated Voltage Measurement... 18:11:41 Voltage Offset Correction: v_off_ini = 2476.698 uV, v_off_fin = 2471.366 uV 18:11:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -197.106 uVs 18:11:41 Integrated Voltage Measurement... 18:11:50 Voltage Offset Correction: v_off_ini = 2490.048 uV, v_off_fin = 2503.793 uV 18:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 182.532 uVs 18:11:53 I2X Average and RMS of Measurements VT = -188.513 +- 1.937 uVs I2X = 17.343 +- 0.178 uTm^2 18:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:12:00 Integrated Voltage Measurement... 18:12:09 Voltage Offset Correction: v_off_ini = 2493.401 uV, v_off_fin = 2522.048 uV 18:12:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -304.019 uVs 18:12:09 Integrated Voltage Measurement... 18:12:18 Voltage Offset Correction: v_off_ini = 2500.184 uV, v_off_fin = 2499.428 uV 18:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.999 uVs 18:12:19 Integrated Voltage Measurement... 18:12:27 Voltage Offset Correction: v_off_ini = 2485.371 uV, v_off_fin = 2495.171 uV 18:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.457 uVs 18:12:28 Integrated Voltage Measurement... 18:12:37 Voltage Offset Correction: v_off_ini = 2506.017 uV, v_off_fin = 2494.036 uV 18:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.132 uVs 18:12:37 Integrated Voltage Measurement... 18:12:46 Voltage Offset Correction: v_off_ini = 2493.215 uV, v_off_fin = 2505.753 uV 18:12:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.498 uVs 18:12:46 Integrated Voltage Measurement... 18:12:55 Voltage Offset Correction: v_off_ini = 2516.439 uV, v_off_fin = 2505.124 uV 18:12:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.265 uVs 18:12:57 I2Y Average and RMS of Measurements VT = -309.395 +- 10.328 uVs I2Y = -28.465 +- 0.950 uTm^2 18:13:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:13:13 Integrated Voltage Measurement... 18:13:22 Voltage Offset Correction: v_off_ini = 2507.620 uV, v_off_fin = 2501.467 uV 18:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.893 uVs 18:13:22 Integrated Voltage Measurement... 18:13:31 Voltage Offset Correction: v_off_ini = 2505.758 uV, v_off_fin = 2503.933 uV 18:13:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.168 uVs 18:13:31 Integrated Voltage Measurement... 18:13:40 Voltage Offset Correction: v_off_ini = 2491.595 uV, v_off_fin = 2493.373 uV 18:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.933 uVs 18:13:40 Integrated Voltage Measurement... 18:13:49 Voltage Offset Correction: v_off_ini = 2491.541 uV, v_off_fin = 2482.234 uV 18:13:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 195.193 uVs 18:13:49 Integrated Voltage Measurement... 18:13:58 Voltage Offset Correction: v_off_ini = 2470.211 uV, v_off_fin = 2488.854 uV 18:13:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.419 uVs 18:13:58 Integrated Voltage Measurement... 18:14:07 Voltage Offset Correction: v_off_ini = 2512.722 uV, v_off_fin = 2516.554 uV 18:14:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 201.161 uVs 18:14:11 I1X Average and RMS of Measurements VT = -189.628 +- 3.781 uVs I1X = 37.926 +- 0.756 uTm 18:14:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:14:18 Integrated Voltage Measurement... 18:14:27 Voltage Offset Correction: v_off_ini = 2470.801 uV, v_off_fin = 2461.116 uV 18:14:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -250.197 uVs 18:14:27 Integrated Voltage Measurement... 18:14:36 Voltage Offset Correction: v_off_ini = 2492.107 uV, v_off_fin = 2492.389 uV 18:14:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.333 uVs 18:14:36 Integrated Voltage Measurement... 18:14:45 Voltage Offset Correction: v_off_ini = 2493.052 uV, v_off_fin = 2465.603 uV 18:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.627 uVs 18:14:45 Integrated Voltage Measurement... 18:14:54 Voltage Offset Correction: v_off_ini = 2484.150 uV, v_off_fin = 2488.886 uV 18:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.230 uVs 18:14:54 Integrated Voltage Measurement... 18:15:03 Voltage Offset Correction: v_off_ini = 2508.648 uV, v_off_fin = 2478.852 uV 18:15:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -284.268 uVs 18:15:03 Integrated Voltage Measurement... 18:15:12 Voltage Offset Correction: v_off_ini = 2504.314 uV, v_off_fin = 2506.942 uV 18:15:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 272.217 uVs 18:15:16 I1Y Average and RMS of Measurements VT = -263.979 +- 10.757 uVs I1Y = -52.793 +- 2.149 uTm 18:15:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:15:24 Integrated Voltage Measurement... 18:15:33 Voltage Offset Correction: v_off_ini = 2475.453 uV, v_off_fin = 2482.800 uV 18:15:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -229.058 uVs 18:15:33 Integrated Voltage Measurement... 18:15:42 Voltage Offset Correction: v_off_ini = 2481.806 uV, v_off_fin = 2511.017 uV 18:15:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 208.528 uVs 18:15:42 Integrated Voltage Measurement... 18:15:51 Voltage Offset Correction: v_off_ini = 2509.237 uV, v_off_fin = 2489.081 uV 18:15:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -203.421 uVs 18:15:51 Integrated Voltage Measurement... 18:16:00 Voltage Offset Correction: v_off_ini = 2498.563 uV, v_off_fin = 2523.271 uV 18:16:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 207.871 uVs 18:16:00 Integrated Voltage Measurement... 18:16:09 Voltage Offset Correction: v_off_ini = 2506.577 uV, v_off_fin = 2492.717 uV 18:16:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -204.125 uVs 18:16:09 Integrated Voltage Measurement... 18:16:18 Voltage Offset Correction: v_off_ini = 2496.717 uV, v_off_fin = 2494.680 uV 18:16:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 195.395 uVs 18:16:20 I2X Average and RMS of Measurements VT = -208.066 +- 7.956 uVs I2X = 19.142 +- 0.732 uTm^2 18:16:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:16:28 Integrated Voltage Measurement... 18:16:37 Voltage Offset Correction: v_off_ini = 2514.354 uV, v_off_fin = 2508.348 uV 18:16:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.499 uVs 18:16:37 Integrated Voltage Measurement... 18:16:46 Voltage Offset Correction: v_off_ini = 2506.497 uV, v_off_fin = 2520.298 uV 18:16:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.680 uVs 18:16:46 Integrated Voltage Measurement... 18:16:55 Voltage Offset Correction: v_off_ini = 2510.532 uV, v_off_fin = 2521.523 uV 18:16:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.120 uVs 18:16:55 Integrated Voltage Measurement... 18:17:04 Voltage Offset Correction: v_off_ini = 2510.327 uV, v_off_fin = 2496.383 uV 18:17:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.026 uVs 18:17:04 Integrated Voltage Measurement... 18:17:13 Voltage Offset Correction: v_off_ini = 2489.323 uV, v_off_fin = 2487.417 uV 18:17:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.465 uVs 18:17:13 Integrated Voltage Measurement... 18:17:22 Voltage Offset Correction: v_off_ini = 2521.824 uV, v_off_fin = 2511.855 uV 18:17:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.048 uVs 18:17:24 I2Y Average and RMS of Measurements VT = -323.473 +- 2.602 uVs I2Y = -29.760 +- 0.239 uTm^2 18:17:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:17:40 Integrated Voltage Measurement... 18:17:49 Voltage Offset Correction: v_off_ini = 2522.980 uV, v_off_fin = 2526.012 uV 18:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -215.245 uVs 18:17:49 Integrated Voltage Measurement... 18:17:58 Voltage Offset Correction: v_off_ini = 2519.141 uV, v_off_fin = 2522.658 uV 18:17:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 220.407 uVs 18:17:58 Integrated Voltage Measurement... 18:18:07 Voltage Offset Correction: v_off_ini = 2545.174 uV, v_off_fin = 2519.352 uV 18:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -216.654 uVs 18:18:07 Integrated Voltage Measurement... 18:18:16 Voltage Offset Correction: v_off_ini = 2509.882 uV, v_off_fin = 2524.246 uV 18:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 198.640 uVs 18:18:16 Integrated Voltage Measurement... 18:18:25 Voltage Offset Correction: v_off_ini = 2520.790 uV, v_off_fin = 2518.162 uV 18:18:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.194 uVs 18:18:25 Integrated Voltage Measurement... 18:18:34 Voltage Offset Correction: v_off_ini = 2536.259 uV, v_off_fin = 2523.772 uV 18:18:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.170 uVs 18:18:39 I1X Average and RMS of Measurements VT = -206.052 +- 10.327 uVs I1X = 41.211 +- 2.066 uTm 18:18:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:18:45 Integrated Voltage Measurement... 18:18:54 Voltage Offset Correction: v_off_ini = 2506.516 uV, v_off_fin = 2496.893 uV 18:18:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.617 uVs 18:18:54 Integrated Voltage Measurement... 18:19:03 Voltage Offset Correction: v_off_ini = 2534.015 uV, v_off_fin = 2560.262 uV 18:19:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 275.723 uVs 18:19:03 Integrated Voltage Measurement... 18:19:12 Voltage Offset Correction: v_off_ini = 2510.179 uV, v_off_fin = 2531.918 uV 18:19:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -275.711 uVs 18:19:12 Integrated Voltage Measurement... 18:19:21 Voltage Offset Correction: v_off_ini = 2546.858 uV, v_off_fin = 2559.042 uV 18:19:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.755 uVs 18:19:21 Integrated Voltage Measurement... 18:19:30 Voltage Offset Correction: v_off_ini = 2526.701 uV, v_off_fin = 2517.782 uV 18:19:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -264.284 uVs 18:19:30 Integrated Voltage Measurement... 18:19:39 Voltage Offset Correction: v_off_ini = 2530.127 uV, v_off_fin = 2547.048 uV 18:19:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 278.994 uVs 18:19:43 I1Y Average and RMS of Measurements VT = -271.014 +- 1.717 uVs I1Y = -54.199 +- 0.343 uTm 18:19:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:19:51 Integrated Voltage Measurement... 18:20:00 Voltage Offset Correction: v_off_ini = 2525.086 uV, v_off_fin = 2511.821 uV 18:20:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -198.898 uVs 18:20:00 Integrated Voltage Measurement... 18:20:09 Voltage Offset Correction: v_off_ini = 2533.394 uV, v_off_fin = 2546.169 uV 18:20:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 189.488 uVs 18:20:09 Integrated Voltage Measurement... 18:20:18 Voltage Offset Correction: v_off_ini = 2519.252 uV, v_off_fin = 2526.248 uV 18:20:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -188.279 uVs 18:20:18 Integrated Voltage Measurement... 18:20:27 Voltage Offset Correction: v_off_ini = 2497.556 uV, v_off_fin = 2513.097 uV 18:20:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 207.244 uVs 18:20:27 Integrated Voltage Measurement... 18:20:36 Voltage Offset Correction: v_off_ini = 2512.571 uV, v_off_fin = 2509.103 uV 18:20:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -207.218 uVs 18:20:36 Integrated Voltage Measurement... 18:20:45 Voltage Offset Correction: v_off_ini = 2513.517 uV, v_off_fin = 2517.857 uV 18:20:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 220.564 uVs 18:20:48 I2X Average and RMS of Measurements VT = -201.948 +- 8.569 uVs I2X = 18.579 +- 0.788 uTm^2 18:20:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:20:55 Integrated Voltage Measurement... 18:21:04 Voltage Offset Correction: v_off_ini = 2500.488 uV, v_off_fin = 2514.097 uV 18:21:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.202 uVs 18:21:04 Integrated Voltage Measurement... 18:21:13 Voltage Offset Correction: v_off_ini = 2485.778 uV, v_off_fin = 2490.749 uV 18:21:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.966 uVs 18:21:13 Integrated Voltage Measurement... 18:21:22 Voltage Offset Correction: v_off_ini = 2483.829 uV, v_off_fin = 2501.346 uV 18:21:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.623 uVs 18:21:22 Integrated Voltage Measurement... 18:21:31 Voltage Offset Correction: v_off_ini = 2490.008 uV, v_off_fin = 2485.037 uV 18:21:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.741 uVs 18:21:31 Integrated Voltage Measurement... 18:21:40 Voltage Offset Correction: v_off_ini = 2485.760 uV, v_off_fin = 2478.528 uV 18:21:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.047 uVs 18:21:40 Integrated Voltage Measurement... 18:21:49 Voltage Offset Correction: v_off_ini = 2476.448 uV, v_off_fin = 2479.581 uV 18:21:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.161 uVs 18:21:52 I2Y Average and RMS of Measurements VT = -318.457 +- 2.449 uVs I2Y = -29.298 +- 0.225 uTm^2 18:22:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:22:10 Integrated Voltage Measurement... 18:22:19 Voltage Offset Correction: v_off_ini = 2486.997 uV, v_off_fin = 2466.411 uV 18:22:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -213.084 uVs 18:22:19 Integrated Voltage Measurement... 18:22:28 Voltage Offset Correction: v_off_ini = 2451.590 uV, v_off_fin = 2451.639 uV 18:22:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.923 uVs 18:22:28 Integrated Voltage Measurement... 18:22:37 Voltage Offset Correction: v_off_ini = 2475.639 uV, v_off_fin = 2460.912 uV 18:22:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -207.887 uVs 18:22:37 Integrated Voltage Measurement... 18:22:46 Voltage Offset Correction: v_off_ini = 2464.027 uV, v_off_fin = 2465.121 uV 18:22:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 213.108 uVs 18:22:46 Integrated Voltage Measurement... 18:22:55 Voltage Offset Correction: v_off_ini = 2461.036 uV, v_off_fin = 2450.821 uV 18:22:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.005 uVs 18:22:55 Integrated Voltage Measurement... 18:23:04 Voltage Offset Correction: v_off_ini = 2452.590 uV, v_off_fin = 2456.974 uV 18:23:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 205.589 uVs 18:23:08 I1X Average and RMS of Measurements VT = -203.766 +- 5.006 uVs I1X = 40.753 +- 1.001 uTm 18:23:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:23:15 Integrated Voltage Measurement... 18:23:24 Voltage Offset Correction: v_off_ini = 2436.283 uV, v_off_fin = 2433.662 uV 18:23:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.105 uVs 18:23:24 Integrated Voltage Measurement... 18:23:33 Voltage Offset Correction: v_off_ini = 2443.300 uV, v_off_fin = 2467.882 uV 18:23:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 308.987 uVs 18:23:33 Integrated Voltage Measurement... 18:23:42 Voltage Offset Correction: v_off_ini = 2453.006 uV, v_off_fin = 2428.888 uV 18:23:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.834 uVs 18:23:42 Integrated Voltage Measurement... 18:23:51 Voltage Offset Correction: v_off_ini = 2444.014 uV, v_off_fin = 2437.126 uV 18:23:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 270.229 uVs 18:23:51 Integrated Voltage Measurement... 18:24:00 Voltage Offset Correction: v_off_ini = 2426.640 uV, v_off_fin = 2427.081 uV 18:24:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.963 uVs 18:24:00 Integrated Voltage Measurement... 18:24:09 Voltage Offset Correction: v_off_ini = 2442.723 uV, v_off_fin = 2443.573 uV 18:24:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 271.124 uVs 18:24:13 I1Y Average and RMS of Measurements VT = -273.873 +- 11.653 uVs I1Y = -54.775 +- 2.328 uTm 18:24:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:24:21 Integrated Voltage Measurement... 18:24:30 Voltage Offset Correction: v_off_ini = 2421.628 uV, v_off_fin = 2442.457 uV 18:24:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -203.118 uVs 18:24:30 Integrated Voltage Measurement... 18:24:39 Voltage Offset Correction: v_off_ini = 2438.738 uV, v_off_fin = 2454.872 uV 18:24:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 228.205 uVs 18:24:39 Integrated Voltage Measurement... 18:24:48 Voltage Offset Correction: v_off_ini = 2434.669 uV, v_off_fin = 2434.648 uV 18:24:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -217.018 uVs 18:24:48 Integrated Voltage Measurement... 18:24:57 Voltage Offset Correction: v_off_ini = 2416.670 uV, v_off_fin = 2435.984 uV 18:24:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 218.536 uVs 18:24:57 Integrated Voltage Measurement... 18:25:06 Voltage Offset Correction: v_off_ini = 2423.208 uV, v_off_fin = 2413.713 uV 18:25:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -210.828 uVs 18:25:06 Integrated Voltage Measurement... 18:25:15 Voltage Offset Correction: v_off_ini = 2465.304 uV, v_off_fin = 2465.774 uV 18:25:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 212.159 uVs 18:25:17 I2X Average and RMS of Measurements VT = -214.977 +- 2.610 uVs I2X = 19.778 +- 0.240 uTm^2 18:25:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:25:25 Integrated Voltage Measurement... 18:25:34 Voltage Offset Correction: v_off_ini = 2449.986 uV, v_off_fin = 2464.207 uV 18:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.655 uVs 18:25:34 Integrated Voltage Measurement... 18:25:43 Voltage Offset Correction: v_off_ini = 2436.959 uV, v_off_fin = 2448.820 uV 18:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.878 uVs 18:25:43 Integrated Voltage Measurement... 18:25:52 Voltage Offset Correction: v_off_ini = 2473.425 uV, v_off_fin = 2462.191 uV 18:25:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.759 uVs 18:25:52 Integrated Voltage Measurement... 18:26:01 Voltage Offset Correction: v_off_ini = 2427.900 uV, v_off_fin = 2455.172 uV 18:26:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.491 uVs 18:26:01 Integrated Voltage Measurement... 18:26:10 Voltage Offset Correction: v_off_ini = 2461.450 uV, v_off_fin = 2451.469 uV 18:26:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.566 uVs 18:26:10 Integrated Voltage Measurement... 18:26:19 Voltage Offset Correction: v_off_ini = 2439.949 uV, v_off_fin = 2449.337 uV 18:26:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.090 uVs 18:26:21 I2Y Average and RMS of Measurements VT = -325.073 +- 9.810 uVs I2Y = -29.907 +- 0.903 uTm^2 18:26:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:26:40 Integrated Voltage Measurement... 18:26:49 Voltage Offset Correction: v_off_ini = 2454.663 uV, v_off_fin = 2457.584 uV 18:26:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -218.179 uVs 18:26:49 Integrated Voltage Measurement... 18:26:58 Voltage Offset Correction: v_off_ini = 2449.055 uV, v_off_fin = 2453.989 uV 18:26:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.608 uVs 18:26:58 Integrated Voltage Measurement... 18:27:07 Voltage Offset Correction: v_off_ini = 2448.952 uV, v_off_fin = 2430.172 uV 18:27:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -192.876 uVs 18:27:07 Integrated Voltage Measurement... 18:27:16 Voltage Offset Correction: v_off_ini = 2435.825 uV, v_off_fin = 2433.055 uV 18:27:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 220.462 uVs 18:27:16 Integrated Voltage Measurement... 18:27:25 Voltage Offset Correction: v_off_ini = 2417.509 uV, v_off_fin = 2408.274 uV 18:27:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.086 uVs 18:27:25 Integrated Voltage Measurement... 18:27:34 Voltage Offset Correction: v_off_ini = 2433.204 uV, v_off_fin = 2438.269 uV 18:27:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 213.731 uVs 18:27:38 I1X Average and RMS of Measurements VT = -203.157 +- 3.493 uVs I1X = 40.632 +- 0.699 uTm 18:27:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:27:45 Integrated Voltage Measurement... 18:27:54 Voltage Offset Correction: v_off_ini = 2431.111 uV, v_off_fin = 2427.742 uV 18:27:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -264.529 uVs 18:27:54 Integrated Voltage Measurement... 18:28:03 Voltage Offset Correction: v_off_ini = 2417.514 uV, v_off_fin = 2421.630 uV 18:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 262.863 uVs 18:28:03 Integrated Voltage Measurement... 18:28:12 Voltage Offset Correction: v_off_ini = 2436.596 uV, v_off_fin = 2427.250 uV 18:28:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -274.482 uVs 18:28:12 Integrated Voltage Measurement... 18:28:21 Voltage Offset Correction: v_off_ini = 2475.607 uV, v_off_fin = 2459.907 uV 18:28:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.005 uVs 18:28:21 Integrated Voltage Measurement... 18:28:30 Voltage Offset Correction: v_off_ini = 2471.804 uV, v_off_fin = 2455.835 uV 18:28:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.821 uVs 18:28:30 Integrated Voltage Measurement... 18:28:39 Voltage Offset Correction: v_off_ini = 2490.261 uV, v_off_fin = 2510.430 uV 18:28:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 260.317 uVs 18:28:43 I1Y Average and RMS of Measurements VT = -262.670 +- 1.852 uVs I1Y = -52.533 +- 0.368 uTm 18:28:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:28:50 Integrated Voltage Measurement... 18:28:59 Voltage Offset Correction: v_off_ini = 2473.690 uV, v_off_fin = 2454.543 uV 18:28:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -215.021 uVs 18:29:00 Integrated Voltage Measurement... 18:29:08 Voltage Offset Correction: v_off_ini = 2481.118 uV, v_off_fin = 2499.055 uV 18:29:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 208.019 uVs 18:29:09 Integrated Voltage Measurement... 18:29:17 Voltage Offset Correction: v_off_ini = 2485.966 uV, v_off_fin = 2500.624 uV 18:29:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -202.140 uVs 18:29:18 Integrated Voltage Measurement... 18:29:27 Voltage Offset Correction: v_off_ini = 2479.122 uV, v_off_fin = 2482.392 uV 18:29:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 213.157 uVs 18:29:27 Integrated Voltage Measurement... 18:29:36 Voltage Offset Correction: v_off_ini = 2480.509 uV, v_off_fin = 2483.781 uV 18:29:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -225.941 uVs 18:29:36 Integrated Voltage Measurement... 18:29:45 Voltage Offset Correction: v_off_ini = 2483.233 uV, v_off_fin = 2491.795 uV 18:29:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 192.919 uVs 18:29:47 I2X Average and RMS of Measurements VT = -209.533 +- 1.582 uVs I2X = 19.277 +- 0.145 uTm^2 18:29:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:29:55 Integrated Voltage Measurement... 18:30:04 Voltage Offset Correction: v_off_ini = 2505.487 uV, v_off_fin = 2498.156 uV 18:30:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.373 uVs 18:30:04 Integrated Voltage Measurement... 18:30:13 Voltage Offset Correction: v_off_ini = 2482.442 uV, v_off_fin = 2473.968 uV 18:30:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.995 uVs 18:30:13 Integrated Voltage Measurement... 18:30:22 Voltage Offset Correction: v_off_ini = 2458.626 uV, v_off_fin = 2495.898 uV 18:30:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.018 uVs 18:30:22 Integrated Voltage Measurement... 18:30:31 Voltage Offset Correction: v_off_ini = 2484.251 uV, v_off_fin = 2485.202 uV 18:30:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.082 uVs 18:30:31 Integrated Voltage Measurement... 18:30:40 Voltage Offset Correction: v_off_ini = 2474.520 uV, v_off_fin = 2472.631 uV 18:30:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.231 uVs 18:30:40 Integrated Voltage Measurement... 18:30:49 Voltage Offset Correction: v_off_ini = 2474.601 uV, v_off_fin = 2464.331 uV 18:30:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.915 uVs 18:30:51 I2Y Average and RMS of Measurements VT = -307.436 +- 5.599 uVs I2Y = -28.284 +- 0.515 uTm^2 18:31:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:31:10 Integrated Voltage Measurement... 18:31:19 Voltage Offset Correction: v_off_ini = 2446.981 uV, v_off_fin = 2461.489 uV 18:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -188.490 uVs 18:31:19 Integrated Voltage Measurement... 18:31:28 Voltage Offset Correction: v_off_ini = 2480.295 uV, v_off_fin = 2477.099 uV 18:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.956 uVs 18:31:28 Integrated Voltage Measurement... 18:31:37 Voltage Offset Correction: v_off_ini = 2474.416 uV, v_off_fin = 2501.394 uV 18:31:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.819 uVs 18:31:37 Integrated Voltage Measurement... 18:31:46 Voltage Offset Correction: v_off_ini = 2491.078 uV, v_off_fin = 2484.183 uV 18:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.072 uVs 18:31:46 Integrated Voltage Measurement... 18:31:55 Voltage Offset Correction: v_off_ini = 2474.416 uV, v_off_fin = 2483.021 uV 18:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.930 uVs 18:31:55 Integrated Voltage Measurement... 18:32:04 Voltage Offset Correction: v_off_ini = 2479.813 uV, v_off_fin = 2493.655 uV 18:32:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 185.279 uVs 18:32:08 I1X Average and RMS of Measurements VT = -187.925 +- 4.265 uVs I1X = 37.586 +- 0.854 uTm 18:32:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:32:15 Integrated Voltage Measurement... 18:32:24 Voltage Offset Correction: v_off_ini = 2495.071 uV, v_off_fin = 2489.782 uV 18:32:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.510 uVs 18:32:24 Integrated Voltage Measurement... 18:32:33 Voltage Offset Correction: v_off_ini = 2491.237 uV, v_off_fin = 2497.867 uV 18:32:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.986 uVs 18:32:33 Integrated Voltage Measurement... 18:32:42 Voltage Offset Correction: v_off_ini = 2478.522 uV, v_off_fin = 2471.378 uV 18:32:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -253.672 uVs 18:32:42 Integrated Voltage Measurement... 18:32:51 Voltage Offset Correction: v_off_ini = 2475.713 uV, v_off_fin = 2482.594 uV 18:32:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.408 uVs 18:32:51 Integrated Voltage Measurement... 18:33:00 Voltage Offset Correction: v_off_ini = 2479.809 uV, v_off_fin = 2473.426 uV 18:33:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.392 uVs 18:33:00 Integrated Voltage Measurement... 18:33:09 Voltage Offset Correction: v_off_ini = 2465.136 uV, v_off_fin = 2480.694 uV 18:33:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.098 uVs 18:33:13 I1Y Average and RMS of Measurements VT = -255.511 +- 1.255 uVs I1Y = -51.098 +- 0.251 uTm 18:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:33:21 Integrated Voltage Measurement... 18:33:30 Voltage Offset Correction: v_off_ini = 2436.762 uV, v_off_fin = 2425.648 uV 18:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -199.159 uVs 18:33:30 Integrated Voltage Measurement... 18:33:39 Voltage Offset Correction: v_off_ini = 2428.299 uV, v_off_fin = 2434.416 uV 18:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.599 uVs 18:33:39 Integrated Voltage Measurement... 18:33:48 Voltage Offset Correction: v_off_ini = 2443.995 uV, v_off_fin = 2424.746 uV 18:33:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -192.932 uVs 18:33:48 Integrated Voltage Measurement... 18:33:57 Voltage Offset Correction: v_off_ini = 2422.641 uV, v_off_fin = 2434.655 uV 18:33:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 209.734 uVs 18:33:57 Integrated Voltage Measurement... 18:34:06 Voltage Offset Correction: v_off_ini = 2438.470 uV, v_off_fin = 2424.793 uV 18:34:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -193.729 uVs 18:34:06 Integrated Voltage Measurement... 18:34:15 Voltage Offset Correction: v_off_ini = 2437.775 uV, v_off_fin = 2422.601 uV 18:34:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 188.235 uVs 18:34:17 I2X Average and RMS of Measurements VT = -197.731 +- 4.776 uVs I2X = 18.191 +- 0.439 uTm^2 18:34:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:34:25 Integrated Voltage Measurement... 18:34:34 Voltage Offset Correction: v_off_ini = 2418.153 uV, v_off_fin = 2429.572 uV 18:34:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.819 uVs 18:34:34 Integrated Voltage Measurement... 18:34:43 Voltage Offset Correction: v_off_ini = 2428.739 uV, v_off_fin = 2445.813 uV 18:34:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.670 uVs 18:34:43 Integrated Voltage Measurement... 18:34:52 Voltage Offset Correction: v_off_ini = 2441.656 uV, v_off_fin = 2451.881 uV 18:34:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.213 uVs 18:34:52 Integrated Voltage Measurement... 18:35:01 Voltage Offset Correction: v_off_ini = 2443.111 uV, v_off_fin = 2439.796 uV 18:35:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.384 uVs 18:35:01 Integrated Voltage Measurement... 18:35:10 Voltage Offset Correction: v_off_ini = 2440.346 uV, v_off_fin = 2457.380 uV 18:35:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.613 uVs 18:35:10 Integrated Voltage Measurement... 18:35:19 Voltage Offset Correction: v_off_ini = 2442.856 uV, v_off_fin = 2447.094 uV 18:35:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.853 uVs 18:35:21 I2Y Average and RMS of Measurements VT = -311.425 +- 11.727 uVs I2Y = -28.651 +- 1.079 uTm^2 18:35:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:35:40 Integrated Voltage Measurement... 18:35:49 Voltage Offset Correction: v_off_ini = 2426.671 uV, v_off_fin = 2425.601 uV 18:35:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -194.375 uVs 18:35:49 Integrated Voltage Measurement... 18:35:58 Voltage Offset Correction: v_off_ini = 2426.342 uV, v_off_fin = 2430.110 uV 18:35:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 197.167 uVs 18:35:58 Integrated Voltage Measurement... 18:36:07 Voltage Offset Correction: v_off_ini = 2425.452 uV, v_off_fin = 2408.657 uV 18:36:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.506 uVs 18:36:07 Integrated Voltage Measurement... 18:36:16 Voltage Offset Correction: v_off_ini = 2400.244 uV, v_off_fin = 2412.785 uV 18:36:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.144 uVs 18:36:16 Integrated Voltage Measurement... 18:36:25 Voltage Offset Correction: v_off_ini = 2430.491 uV, v_off_fin = 2453.898 uV 18:36:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -191.138 uVs 18:36:25 Integrated Voltage Measurement... 18:36:34 Voltage Offset Correction: v_off_ini = 2451.032 uV, v_off_fin = 2425.537 uV 18:36:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 196.359 uVs 18:36:38 I1X Average and RMS of Measurements VT = -189.781 +- 7.089 uVs I1X = 37.958 +- 1.417 uTm 18:36:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:36:45 Integrated Voltage Measurement... 18:36:54 Voltage Offset Correction: v_off_ini = 2426.619 uV, v_off_fin = 2410.715 uV 18:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.239 uVs 18:36:54 Integrated Voltage Measurement... 18:37:03 Voltage Offset Correction: v_off_ini = 2417.563 uV, v_off_fin = 2436.416 uV 18:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 249.615 uVs 18:37:03 Integrated Voltage Measurement... 18:37:12 Voltage Offset Correction: v_off_ini = 2410.232 uV, v_off_fin = 2424.614 uV 18:37:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -259.274 uVs 18:37:12 Integrated Voltage Measurement... 18:37:21 Voltage Offset Correction: v_off_ini = 2431.080 uV, v_off_fin = 2423.336 uV 18:37:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.594 uVs 18:37:21 Integrated Voltage Measurement... 18:37:30 Voltage Offset Correction: v_off_ini = 2412.204 uV, v_off_fin = 2414.342 uV 18:37:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -261.556 uVs 18:37:30 Integrated Voltage Measurement... 18:37:39 Voltage Offset Correction: v_off_ini = 2428.673 uV, v_off_fin = 2437.635 uV 18:37:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.711 uVs 18:37:43 I1Y Average and RMS of Measurements VT = -261.665 +- 1.587 uVs I1Y = -52.328 +- 0.315 uTm 18:37:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:37:51 Integrated Voltage Measurement... 18:38:00 Voltage Offset Correction: v_off_ini = 2408.781 uV, v_off_fin = 2416.496 uV 18:38:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.373 uVs 18:38:00 Integrated Voltage Measurement... 18:38:09 Voltage Offset Correction: v_off_ini = 2422.263 uV, v_off_fin = 2450.188 uV 18:38:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.670 uVs 18:38:09 Integrated Voltage Measurement... 18:38:18 Voltage Offset Correction: v_off_ini = 2439.099 uV, v_off_fin = 2432.539 uV 18:38:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -197.913 uVs 18:38:18 Integrated Voltage Measurement... 18:38:27 Voltage Offset Correction: v_off_ini = 2436.093 uV, v_off_fin = 2440.953 uV 18:38:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.354 uVs 18:38:27 Integrated Voltage Measurement... 18:38:36 Voltage Offset Correction: v_off_ini = 2422.308 uV, v_off_fin = 2420.991 uV 18:38:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -205.431 uVs 18:38:36 Integrated Voltage Measurement... 18:38:45 Voltage Offset Correction: v_off_ini = 2413.072 uV, v_off_fin = 2445.494 uV 18:38:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 175.674 uVs 18:38:47 I2X Average and RMS of Measurements VT = -184.903 +- 4.087 uVs I2X = 17.011 +- 0.376 uTm^2 18:38:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:38:55 Integrated Voltage Measurement... 18:39:04 Voltage Offset Correction: v_off_ini = 2441.310 uV, v_off_fin = 2421.211 uV 18:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.781 uVs 18:39:04 Integrated Voltage Measurement... 18:39:13 Voltage Offset Correction: v_off_ini = 2428.016 uV, v_off_fin = 2407.810 uV 18:39:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.241 uVs 18:39:13 Integrated Voltage Measurement... 18:39:22 Voltage Offset Correction: v_off_ini = 2422.426 uV, v_off_fin = 2430.327 uV 18:39:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.926 uVs 18:39:22 Integrated Voltage Measurement... 18:39:31 Voltage Offset Correction: v_off_ini = 2431.002 uV, v_off_fin = 2449.635 uV 18:39:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.222 uVs 18:39:31 Integrated Voltage Measurement... 18:39:40 Voltage Offset Correction: v_off_ini = 2434.295 uV, v_off_fin = 2435.304 uV 18:39:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.338 uVs 18:39:40 Integrated Voltage Measurement... 18:39:49 Voltage Offset Correction: v_off_ini = 2425.936 uV, v_off_fin = 2427.642 uV 18:39:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.577 uVs 18:39:51 I2Y Average and RMS of Measurements VT = -302.848 +- 12.241 uVs I2Y = -27.862 +- 1.126 uTm^2 18:40:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:40:10 Integrated Voltage Measurement... 18:40:19 Voltage Offset Correction: v_off_ini = 2418.866 uV, v_off_fin = 2432.371 uV 18:40:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.801 uVs 18:40:19 Integrated Voltage Measurement... 18:40:28 Voltage Offset Correction: v_off_ini = 2430.322 uV, v_off_fin = 2431.319 uV 18:40:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.107 uVs 18:40:28 Integrated Voltage Measurement... 18:40:37 Voltage Offset Correction: v_off_ini = 2408.079 uV, v_off_fin = 2418.173 uV 18:40:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.296 uVs 18:40:37 Integrated Voltage Measurement... 18:40:46 Voltage Offset Correction: v_off_ini = 2398.363 uV, v_off_fin = 2424.535 uV 18:40:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.808 uVs 18:40:46 Integrated Voltage Measurement... 18:40:55 Voltage Offset Correction: v_off_ini = 2441.952 uV, v_off_fin = 2433.537 uV 18:40:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -186.684 uVs 18:40:55 Integrated Voltage Measurement... 18:41:04 Voltage Offset Correction: v_off_ini = 2432.827 uV, v_off_fin = 2417.282 uV 18:41:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.335 uVs 18:41:08 I1X Average and RMS of Measurements VT = -176.005 +- 10.998 uVs I1X = 35.201 +- 2.200 uTm 18:41:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:41:15 Integrated Voltage Measurement... 18:41:24 Voltage Offset Correction: v_off_ini = 2433.777 uV, v_off_fin = 2426.812 uV 18:41:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -258.032 uVs 18:41:24 Integrated Voltage Measurement... 18:41:33 Voltage Offset Correction: v_off_ini = 2419.739 uV, v_off_fin = 2417.697 uV 18:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.098 uVs 18:41:33 Integrated Voltage Measurement... 18:41:42 Voltage Offset Correction: v_off_ini = 2423.510 uV, v_off_fin = 2424.187 uV 18:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -231.299 uVs 18:41:42 Integrated Voltage Measurement... 18:41:51 Voltage Offset Correction: v_off_ini = 2439.134 uV, v_off_fin = 2457.782 uV 18:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 265.901 uVs 18:41:51 Integrated Voltage Measurement... 18:42:00 Voltage Offset Correction: v_off_ini = 2429.998 uV, v_off_fin = 2413.780 uV 18:42:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.252 uVs 18:42:00 Integrated Voltage Measurement... 18:42:09 Voltage Offset Correction: v_off_ini = 2419.602 uV, v_off_fin = 2423.906 uV 18:42:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.228 uVs 18:42:13 I1Y Average and RMS of Measurements VT = -250.968 +- 5.887 uVs I1Y = -50.191 +- 1.181 uTm 18:42:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:42:21 Integrated Voltage Measurement... 18:42:30 Voltage Offset Correction: v_off_ini = 2424.967 uV, v_off_fin = 2436.745 uV 18:42:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.667 uVs 18:42:30 Integrated Voltage Measurement... 18:42:39 Voltage Offset Correction: v_off_ini = 2439.524 uV, v_off_fin = 2434.670 uV 18:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.585 uVs 18:42:39 Integrated Voltage Measurement... 18:42:48 Voltage Offset Correction: v_off_ini = 2429.541 uV, v_off_fin = 2423.744 uV 18:42:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -171.702 uVs 18:42:48 Integrated Voltage Measurement... 18:42:57 Voltage Offset Correction: v_off_ini = 2437.971 uV, v_off_fin = 2441.863 uV 18:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.838 uVs 18:42:57 Integrated Voltage Measurement... 18:43:06 Voltage Offset Correction: v_off_ini = 2427.102 uV, v_off_fin = 2432.688 uV 18:43:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -206.615 uVs 18:43:06 Integrated Voltage Measurement... 18:43:15 Voltage Offset Correction: v_off_ini = 2441.182 uV, v_off_fin = 2454.770 uV 18:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 191.955 uVs 18:43:17 I2X Average and RMS of Measurements VT = -182.060 +- 12.681 uVs I2X = 16.750 +- 1.167 uTm^2 18:43:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:43:25 Integrated Voltage Measurement... 18:43:34 Voltage Offset Correction: v_off_ini = 2458.863 uV, v_off_fin = 2466.077 uV 18:43:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.556 uVs 18:43:34 Integrated Voltage Measurement... 18:43:43 Voltage Offset Correction: v_off_ini = 2454.906 uV, v_off_fin = 2483.122 uV 18:43:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.462 uVs 18:43:43 Integrated Voltage Measurement... 18:43:52 Voltage Offset Correction: v_off_ini = 2479.800 uV, v_off_fin = 2484.243 uV 18:43:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.159 uVs 18:43:52 Integrated Voltage Measurement... 18:44:01 Voltage Offset Correction: v_off_ini = 2466.339 uV, v_off_fin = 2454.574 uV 18:44:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.182 uVs 18:44:01 Integrated Voltage Measurement... 18:44:10 Voltage Offset Correction: v_off_ini = 2462.981 uV, v_off_fin = 2457.897 uV 18:44:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.967 uVs 18:44:10 Integrated Voltage Measurement... 18:44:19 Voltage Offset Correction: v_off_ini = 2456.458 uV, v_off_fin = 2473.225 uV 18:44:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.169 uVs 18:44:21 I2Y Average and RMS of Measurements VT = -296.083 +- 9.976 uVs I2Y = -27.240 +- 0.918 uTm^2 18:44:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:44:40 Integrated Voltage Measurement... 18:44:49 Voltage Offset Correction: v_off_ini = 2464.755 uV, v_off_fin = 2472.547 uV 18:44:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -197.646 uVs 18:44:49 Integrated Voltage Measurement... 18:44:58 Voltage Offset Correction: v_off_ini = 2468.463 uV, v_off_fin = 2468.043 uV 18:44:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.243 uVs 18:44:58 Integrated Voltage Measurement... 18:45:07 Voltage Offset Correction: v_off_ini = 2458.857 uV, v_off_fin = 2458.460 uV 18:45:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -173.335 uVs 18:45:07 Integrated Voltage Measurement... 18:45:16 Voltage Offset Correction: v_off_ini = 2475.768 uV, v_off_fin = 2462.594 uV 18:45:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.934 uVs 18:45:16 Integrated Voltage Measurement... 18:45:25 Voltage Offset Correction: v_off_ini = 2472.815 uV, v_off_fin = 2478.736 uV 18:45:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.108 uVs 18:45:25 Integrated Voltage Measurement... 18:45:34 Voltage Offset Correction: v_off_ini = 2473.758 uV, v_off_fin = 2460.986 uV 18:45:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.976 uVs 18:45:38 I1X Average and RMS of Measurements VT = -179.707 +- 1.583 uVs I1X = 35.942 +- 0.317 uTm 18:45:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:45:45 Integrated Voltage Measurement... 18:45:54 Voltage Offset Correction: v_off_ini = 2464.323 uV, v_off_fin = 2461.484 uV 18:45:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.782 uVs 18:45:54 Integrated Voltage Measurement... 18:46:03 Voltage Offset Correction: v_off_ini = 2443.842 uV, v_off_fin = 2466.567 uV 18:46:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.857 uVs 18:46:03 Integrated Voltage Measurement... 18:46:12 Voltage Offset Correction: v_off_ini = 2446.707 uV, v_off_fin = 2432.514 uV 18:46:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.348 uVs 18:46:12 Integrated Voltage Measurement... 18:46:21 Voltage Offset Correction: v_off_ini = 2456.073 uV, v_off_fin = 2481.464 uV 18:46:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.531 uVs 18:46:21 Integrated Voltage Measurement... 18:46:30 Voltage Offset Correction: v_off_ini = 2475.398 uV, v_off_fin = 2458.318 uV 18:46:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.449 uVs 18:46:30 Integrated Voltage Measurement... 18:46:39 Voltage Offset Correction: v_off_ini = 2459.860 uV, v_off_fin = 2481.281 uV 18:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.070 uVs 18:46:43 I1Y Average and RMS of Measurements VT = -222.506 +- 5.059 uVs I1Y = -44.497 +- 1.012 uTm 18:46:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:46:51 Integrated Voltage Measurement... 18:47:00 Voltage Offset Correction: v_off_ini = 2433.597 uV, v_off_fin = 2429.983 uV 18:47:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -197.520 uVs 18:47:00 Integrated Voltage Measurement... 18:47:09 Voltage Offset Correction: v_off_ini = 2440.801 uV, v_off_fin = 2450.004 uV 18:47:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 200.936 uVs 18:47:09 Integrated Voltage Measurement... 18:47:18 Voltage Offset Correction: v_off_ini = 2439.233 uV, v_off_fin = 2441.118 uV 18:47:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.902 uVs 18:47:18 Integrated Voltage Measurement... 18:47:27 Voltage Offset Correction: v_off_ini = 2438.021 uV, v_off_fin = 2449.887 uV 18:47:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 176.872 uVs 18:47:27 Integrated Voltage Measurement... 18:47:36 Voltage Offset Correction: v_off_ini = 2427.810 uV, v_off_fin = 2414.351 uV 18:47:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -182.405 uVs 18:47:36 Integrated Voltage Measurement... 18:47:45 Voltage Offset Correction: v_off_ini = 2427.672 uV, v_off_fin = 2451.048 uV 18:47:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.254 uVs 18:47:47 I2X Average and RMS of Measurements VT = -188.648 +- 11.361 uVs I2X = 17.356 +- 1.045 uTm^2 18:47:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:47:55 Integrated Voltage Measurement... 18:48:04 Voltage Offset Correction: v_off_ini = 2439.172 uV, v_off_fin = 2430.632 uV 18:48:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.462 uVs 18:48:04 Integrated Voltage Measurement... 18:48:13 Voltage Offset Correction: v_off_ini = 2434.474 uV, v_off_fin = 2448.879 uV 18:48:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.192 uVs 18:48:13 Integrated Voltage Measurement... 18:48:22 Voltage Offset Correction: v_off_ini = 2445.011 uV, v_off_fin = 2439.555 uV 18:48:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.677 uVs 18:48:22 Integrated Voltage Measurement... 18:48:31 Voltage Offset Correction: v_off_ini = 2428.754 uV, v_off_fin = 2425.476 uV 18:48:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.742 uVs 18:48:31 Integrated Voltage Measurement... 18:48:40 Voltage Offset Correction: v_off_ini = 2430.199 uV, v_off_fin = 2422.938 uV 18:48:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.187 uVs 18:48:40 Integrated Voltage Measurement... 18:48:49 Voltage Offset Correction: v_off_ini = 2416.116 uV, v_off_fin = 2416.763 uV 18:48:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.313 uVs 18:48:51 I2Y Average and RMS of Measurements VT = -254.095 +- 5.990 uVs I2Y = -23.377 +- 0.551 uTm^2 18:48:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:07:49 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm