SLAC Magnetic Measurements Date: 07-17-2025 Time: 16:49:56 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16353 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 8 Measurement Device: Operator: YL Comment: Off Axis 16:50:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:05 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:50:07 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:50:09 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:50:10 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:50:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:50:54 Integrated Voltage Measurement... 16:51:02 Voltage Offset Correction: v_off_ini = 597.888 uV, v_off_fin = 614.131 uV 16:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.725 uVs 16:51:03 Integrated Voltage Measurement... 16:51:12 Voltage Offset Correction: v_off_ini = 612.003 uV, v_off_fin = 612.978 uV 16:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.657 uVs 16:51:12 Integrated Voltage Measurement... 16:51:21 Voltage Offset Correction: v_off_ini = 610.171 uV, v_off_fin = 619.257 uV 16:51:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.245 uVs 16:51:21 Integrated Voltage Measurement... 16:51:30 Voltage Offset Correction: v_off_ini = 606.270 uV, v_off_fin = 615.201 uV 16:51:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.601 uVs 16:51:30 Integrated Voltage Measurement... 16:51:39 Voltage Offset Correction: v_off_ini = 615.693 uV, v_off_fin = 616.265 uV 16:51:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.325 uVs 16:51:39 Integrated Voltage Measurement... 16:51:48 Voltage Offset Correction: v_off_ini = 611.289 uV, v_off_fin = 613.358 uV 16:51:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.353 uVs 16:51:52 I1X Average and RMS of Measurements VT = -37.818 +- 7.413 uVs I1X = 7.564 +- 1.483 uTm 16:51:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:51:59 Integrated Voltage Measurement... 16:52:08 Voltage Offset Correction: v_off_ini = 615.005 uV, v_off_fin = 602.132 uV 16:52:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -192.500 uVs 16:52:08 Integrated Voltage Measurement... 16:52:17 Voltage Offset Correction: v_off_ini = 617.801 uV, v_off_fin = 632.315 uV 16:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.261 uVs 16:52:17 Integrated Voltage Measurement... 16:52:26 Voltage Offset Correction: v_off_ini = 620.140 uV, v_off_fin = 611.032 uV 16:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.348 uVs 16:52:26 Integrated Voltage Measurement... 16:52:35 Voltage Offset Correction: v_off_ini = 620.191 uV, v_off_fin = 638.814 uV 16:52:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.651 uVs 16:52:35 Integrated Voltage Measurement... 16:52:44 Voltage Offset Correction: v_off_ini = 627.426 uV, v_off_fin = 608.306 uV 16:52:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.965 uVs 16:52:44 Integrated Voltage Measurement... 16:52:53 Voltage Offset Correction: v_off_ini = 619.085 uV, v_off_fin = 629.736 uV 16:52:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.290 uVs 16:52:57 I1Y Average and RMS of Measurements VT = -184.169 +- 4.404 uVs I1Y = -36.836 +- 0.882 uTm 16:53:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:53:05 Integrated Voltage Measurement... 16:53:14 Voltage Offset Correction: v_off_ini = 619.305 uV, v_off_fin = 616.168 uV 16:53:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 10.421 uVs 16:53:14 Integrated Voltage Measurement... 16:53:23 Voltage Offset Correction: v_off_ini = 631.107 uV, v_off_fin = 632.441 uV 16:53:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -19.892 uVs 16:53:23 Integrated Voltage Measurement... 16:53:32 Voltage Offset Correction: v_off_ini = 615.242 uV, v_off_fin = 610.887 uV 16:53:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 42.316 uVs 16:53:32 Integrated Voltage Measurement... 16:53:41 Voltage Offset Correction: v_off_ini = 600.289 uV, v_off_fin = 618.935 uV 16:53:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 7.247 uVs 16:53:41 Integrated Voltage Measurement... 16:53:50 Voltage Offset Correction: v_off_ini = 614.030 uV, v_off_fin = 620.403 uV 16:53:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 16.507 uVs 16:53:50 Integrated Voltage Measurement... 16:53:59 Voltage Offset Correction: v_off_ini = 623.366 uV, v_off_fin = 633.099 uV 16:53:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -10.185 uVs 16:54:01 I2X Average and RMS of Measurements VT = 15.346 +- 1.715 uVs I2X = -1.412 +- 0.158 uTm^2 16:54:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:54:09 Integrated Voltage Measurement... 16:54:18 Voltage Offset Correction: v_off_ini = 625.737 uV, v_off_fin = 621.598 uV 16:54:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.295 uVs 16:54:18 Integrated Voltage Measurement... 16:54:27 Voltage Offset Correction: v_off_ini = 623.634 uV, v_off_fin = 622.457 uV 16:54:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 495.644 uVs 16:54:27 Integrated Voltage Measurement... 16:54:36 Voltage Offset Correction: v_off_ini = 631.401 uV, v_off_fin = 617.243 uV 16:54:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -499.211 uVs 16:54:36 Integrated Voltage Measurement... 16:54:45 Voltage Offset Correction: v_off_ini = 625.960 uV, v_off_fin = 617.290 uV 16:54:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 532.534 uVs 16:54:45 Integrated Voltage Measurement... 16:54:54 Voltage Offset Correction: v_off_ini = 622.482 uV, v_off_fin = 619.451 uV 16:54:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -550.610 uVs 16:54:54 Integrated Voltage Measurement... 16:55:03 Voltage Offset Correction: v_off_ini = 611.425 uV, v_off_fin = 608.719 uV 16:55:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 534.052 uVs 16:55:06 I2Y Average and RMS of Measurements VT = -521.724 +- 15.018 uVs I2Y = -47.999 +- 1.382 uTm^2 16:55:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:55:15 Integrated Voltage Measurement... 16:55:24 Voltage Offset Correction: v_off_ini = 615.568 uV, v_off_fin = 621.498 uV 16:55:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -22.421 uVs 16:55:24 Integrated Voltage Measurement... 16:55:33 Voltage Offset Correction: v_off_ini = 615.289 uV, v_off_fin = 616.384 uV 16:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.023 uVs 16:55:33 Integrated Voltage Measurement... 16:55:42 Voltage Offset Correction: v_off_ini = 607.777 uV, v_off_fin = 613.766 uV 16:55:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.283 uVs 16:55:42 Integrated Voltage Measurement... 16:55:51 Voltage Offset Correction: v_off_ini = 615.569 uV, v_off_fin = 605.634 uV 16:55:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.588 uVs 16:55:51 Integrated Voltage Measurement... 16:56:00 Voltage Offset Correction: v_off_ini = 613.705 uV, v_off_fin = 616.552 uV 16:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.845 uVs 16:56:00 Integrated Voltage Measurement... 16:56:09 Voltage Offset Correction: v_off_ini = 602.788 uV, v_off_fin = 614.461 uV 16:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.075 uVs 16:56:13 I1X Average and RMS of Measurements VT = -35.706 +- 8.666 uVs I1X = 7.141 +- 1.733 uTm 16:56:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:56:20 Integrated Voltage Measurement... 16:56:29 Voltage Offset Correction: v_off_ini = 605.733 uV, v_off_fin = 612.052 uV 16:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.025 uVs 16:56:29 Integrated Voltage Measurement... 16:56:38 Voltage Offset Correction: v_off_ini = 606.878 uV, v_off_fin = 607.553 uV 16:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.022 uVs 16:56:38 Integrated Voltage Measurement... 16:56:47 Voltage Offset Correction: v_off_ini = 601.246 uV, v_off_fin = 588.522 uV 16:56:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.666 uVs 16:56:47 Integrated Voltage Measurement... 16:56:56 Voltage Offset Correction: v_off_ini = 595.539 uV, v_off_fin = 604.937 uV 16:56:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.849 uVs 16:56:56 Integrated Voltage Measurement... 16:57:05 Voltage Offset Correction: v_off_ini = 597.296 uV, v_off_fin = 593.442 uV 16:57:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.091 uVs 16:57:05 Integrated Voltage Measurement... 16:57:14 Voltage Offset Correction: v_off_ini = 594.662 uV, v_off_fin = 601.493 uV 16:57:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.928 uVs 16:57:18 I1Y Average and RMS of Measurements VT = -186.597 +- 7.457 uVs I1Y = -37.319 +- 1.491 uTm 16:57:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:57:26 Integrated Voltage Measurement... 16:57:35 Voltage Offset Correction: v_off_ini = 608.370 uV, v_off_fin = 582.829 uV 16:57:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 14.497 uVs 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = 603.473 uV, v_off_fin = 619.743 uV 16:57:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -34.439 uVs 16:57:44 Integrated Voltage Measurement... 16:57:53 Voltage Offset Correction: v_off_ini = 594.077 uV, v_off_fin = 584.287 uV 16:57:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 29.611 uVs 16:57:53 Integrated Voltage Measurement... 16:58:02 Voltage Offset Correction: v_off_ini = 602.551 uV, v_off_fin = 627.466 uV 16:58:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -19.355 uVs 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = 614.994 uV, v_off_fin = 597.622 uV 16:58:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.804 uVs 16:58:11 Integrated Voltage Measurement... 16:58:20 Voltage Offset Correction: v_off_ini = 601.475 uV, v_off_fin = 618.187 uV 16:58:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -21.622 uVs 16:58:23 I2X Average and RMS of Measurements VT = 19.787 +- 6.631 uVs I2X = -1.820 +- 0.610 uTm^2 16:58:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:58:30 Integrated Voltage Measurement... 16:58:39 Voltage Offset Correction: v_off_ini = 566.694 uV, v_off_fin = 573.523 uV 16:58:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -511.832 uVs 16:58:39 Integrated Voltage Measurement... 16:58:48 Voltage Offset Correction: v_off_ini = 584.418 uV, v_off_fin = 594.236 uV 16:58:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 511.358 uVs 16:58:48 Integrated Voltage Measurement... 16:58:57 Voltage Offset Correction: v_off_ini = 584.260 uV, v_off_fin = 581.661 uV 16:58:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -520.356 uVs 16:58:58 Integrated Voltage Measurement... 16:59:07 Voltage Offset Correction: v_off_ini = 582.161 uV, v_off_fin = 582.060 uV 16:59:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 519.494 uVs 16:59:07 Integrated Voltage Measurement... 16:59:16 Voltage Offset Correction: v_off_ini = 584.347 uV, v_off_fin = 579.815 uV 16:59:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.662 uVs 16:59:16 Integrated Voltage Measurement... 16:59:25 Voltage Offset Correction: v_off_ini = 591.278 uV, v_off_fin = 595.033 uV 16:59:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.131 uVs 16:59:27 I2Y Average and RMS of Measurements VT = -511.139 +- 7.367 uVs I2Y = -47.025 +- 0.678 uTm^2 16:59:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:36 Integrated Voltage Measurement... 16:59:45 Voltage Offset Correction: v_off_ini = 591.370 uV, v_off_fin = 606.757 uV 16:59:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -38.573 uVs 16:59:45 Integrated Voltage Measurement... 16:59:54 Voltage Offset Correction: v_off_ini = 594.692 uV, v_off_fin = 600.646 uV 16:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.718 uVs 16:59:54 Integrated Voltage Measurement... 17:00:03 Voltage Offset Correction: v_off_ini = 603.580 uV, v_off_fin = 610.863 uV 17:00:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.445 uVs 17:00:03 Integrated Voltage Measurement... 17:00:12 Voltage Offset Correction: v_off_ini = 602.042 uV, v_off_fin = 608.405 uV 17:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.173 uVs 17:00:12 Integrated Voltage Measurement... 17:00:21 Voltage Offset Correction: v_off_ini = 602.779 uV, v_off_fin = 593.572 uV 17:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.267 uVs 17:00:21 Integrated Voltage Measurement... 17:00:30 Voltage Offset Correction: v_off_ini = 597.332 uV, v_off_fin = 596.129 uV 17:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.935 uVs 17:00:34 I1X Average and RMS of Measurements VT = -34.852 +- 4.161 uVs I1X = 6.971 +- 0.832 uTm 17:00:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:41 Integrated Voltage Measurement... 17:00:50 Voltage Offset Correction: v_off_ini = 602.920 uV, v_off_fin = 593.467 uV 17:00:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.979 uVs 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = 596.639 uV, v_off_fin = 618.912 uV 17:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.464 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = 614.273 uV, v_off_fin = 597.593 uV 17:01:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.911 uVs 17:01:08 Integrated Voltage Measurement... 17:01:17 Voltage Offset Correction: v_off_ini = 602.840 uV, v_off_fin = 617.718 uV 17:01:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.707 uVs 17:01:17 Integrated Voltage Measurement... 17:01:26 Voltage Offset Correction: v_off_ini = 599.251 uV, v_off_fin = 597.006 uV 17:01:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.884 uVs 17:01:26 Integrated Voltage Measurement... 17:01:35 Voltage Offset Correction: v_off_ini = 624.997 uV, v_off_fin = 620.135 uV 17:01:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.099 uVs 17:01:39 I1Y Average and RMS of Measurements VT = -175.341 +- 7.078 uVs I1Y = -35.068 +- 1.416 uTm 17:01:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:47 Integrated Voltage Measurement... 17:01:56 Voltage Offset Correction: v_off_ini = 609.034 uV, v_off_fin = 595.237 uV 17:01:56 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -1.636 uVs 17:01:56 Integrated Voltage Measurement... 17:02:05 Voltage Offset Correction: v_off_ini = 602.438 uV, v_off_fin = 622.941 uV 17:02:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -40.704 uVs 17:02:05 Integrated Voltage Measurement... 17:02:14 Voltage Offset Correction: v_off_ini = 610.251 uV, v_off_fin = 608.293 uV 17:02:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 21.154 uVs 17:02:14 Integrated Voltage Measurement... 17:02:23 Voltage Offset Correction: v_off_ini = 616.911 uV, v_off_fin = 623.184 uV 17:02:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -6.574 uVs 17:02:23 Integrated Voltage Measurement... 17:02:32 Voltage Offset Correction: v_off_ini = 616.394 uV, v_off_fin = 619.827 uV 17:02:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.371 uVs 17:02:32 Integrated Voltage Measurement... 17:02:41 Voltage Offset Correction: v_off_ini = 630.115 uV, v_off_fin = 629.810 uV 17:02:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -13.644 uVs 17:02:44 I2X Average and RMS of Measurements VT = 13.635 +- 4.913 uVs I2X = -1.255 +- 0.452 uTm^2 17:02:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:52 Integrated Voltage Measurement... 17:03:01 Voltage Offset Correction: v_off_ini = 626.480 uV, v_off_fin = 623.024 uV 17:03:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.491 uVs 17:03:01 Integrated Voltage Measurement... 17:03:10 Voltage Offset Correction: v_off_ini = 640.809 uV, v_off_fin = 636.413 uV 17:03:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 498.696 uVs 17:03:10 Integrated Voltage Measurement... 17:03:19 Voltage Offset Correction: v_off_ini = 614.673 uV, v_off_fin = 628.703 uV 17:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.968 uVs 17:03:19 Integrated Voltage Measurement... 17:03:28 Voltage Offset Correction: v_off_ini = 624.285 uV, v_off_fin = 627.128 uV 17:03:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.794 uVs 17:03:28 Integrated Voltage Measurement... 17:03:37 Voltage Offset Correction: v_off_ini = 620.385 uV, v_off_fin = 626.096 uV 17:03:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -495.293 uVs 17:03:37 Integrated Voltage Measurement... 17:03:46 Voltage Offset Correction: v_off_ini = 632.942 uV, v_off_fin = 631.472 uV 17:03:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 501.195 uVs 17:03:48 I2Y Average and RMS of Measurements VT = -500.906 +- 3.325 uVs I2Y = -46.084 +- 0.305 uTm^2 17:03:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:03:57 Integrated Voltage Measurement... 17:04:06 Voltage Offset Correction: v_off_ini = 640.652 uV, v_off_fin = 631.745 uV 17:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.813 uVs 17:04:06 Integrated Voltage Measurement... 17:04:15 Voltage Offset Correction: v_off_ini = 642.487 uV, v_off_fin = 633.617 uV 17:04:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.449 uVs 17:04:15 Integrated Voltage Measurement... 17:04:24 Voltage Offset Correction: v_off_ini = 629.675 uV, v_off_fin = 632.534 uV 17:04:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.108 uVs 17:04:24 Integrated Voltage Measurement... 17:04:33 Voltage Offset Correction: v_off_ini = 636.099 uV, v_off_fin = 628.509 uV 17:04:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.747 uVs 17:04:33 Integrated Voltage Measurement... 17:04:42 Voltage Offset Correction: v_off_ini = 643.290 uV, v_off_fin = 634.396 uV 17:04:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.616 uVs 17:04:42 Integrated Voltage Measurement... 17:04:51 Voltage Offset Correction: v_off_ini = 630.139 uV, v_off_fin = 626.272 uV 17:04:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.306 uVs 17:04:56 I1X Average and RMS of Measurements VT = -33.006 +- 3.402 uVs I1X = 6.601 +- 0.680 uTm 17:04:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:05:02 Integrated Voltage Measurement... 17:05:11 Voltage Offset Correction: v_off_ini = 615.444 uV, v_off_fin = 609.446 uV 17:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.530 uVs 17:05:11 Integrated Voltage Measurement... 17:05:20 Voltage Offset Correction: v_off_ini = 626.742 uV, v_off_fin = 627.389 uV 17:05:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.412 uVs 17:05:21 Integrated Voltage Measurement... 17:05:29 Voltage Offset Correction: v_off_ini = 627.324 uV, v_off_fin = 626.332 uV 17:05:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.499 uVs 17:05:30 Integrated Voltage Measurement... 17:05:39 Voltage Offset Correction: v_off_ini = 636.168 uV, v_off_fin = 643.317 uV 17:05:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.363 uVs 17:05:39 Integrated Voltage Measurement... 17:05:48 Voltage Offset Correction: v_off_ini = 628.970 uV, v_off_fin = 622.407 uV 17:05:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.700 uVs 17:05:48 Integrated Voltage Measurement... 17:05:57 Voltage Offset Correction: v_off_ini = 625.986 uV, v_off_fin = 631.528 uV 17:05:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.634 uVs 17:06:01 I1Y Average and RMS of Measurements VT = -173.689 +- 11.061 uVs I1Y = -34.738 +- 2.212 uTm 17:06:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:06:08 Integrated Voltage Measurement... 17:06:17 Voltage Offset Correction: v_off_ini = 626.563 uV, v_off_fin = 624.055 uV 17:06:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 10.870 uVs 17:06:18 Integrated Voltage Measurement... 17:06:27 Voltage Offset Correction: v_off_ini = 641.132 uV, v_off_fin = 639.921 uV 17:06:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -12.717 uVs 17:06:27 Integrated Voltage Measurement... 17:06:36 Voltage Offset Correction: v_off_ini = 633.920 uV, v_off_fin = 620.644 uV 17:06:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.418 uVs 17:06:36 Integrated Voltage Measurement... 17:06:45 Voltage Offset Correction: v_off_ini = 628.625 uV, v_off_fin = 640.363 uV 17:06:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.975 uVs 17:06:45 Integrated Voltage Measurement... 17:06:54 Voltage Offset Correction: v_off_ini = 631.206 uV, v_off_fin = 623.976 uV 17:06:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.624 uVs 17:06:54 Integrated Voltage Measurement... 17:07:03 Voltage Offset Correction: v_off_ini = 630.916 uV, v_off_fin = 644.794 uV 17:07:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.625 uVs 17:07:05 I2X Average and RMS of Measurements VT = 6.372 +- 3.834 uVs I2X = -0.586 +- 0.353 uTm^2 17:07:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:07:13 Integrated Voltage Measurement... 17:07:22 Voltage Offset Correction: v_off_ini = 622.736 uV, v_off_fin = 626.072 uV 17:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.992 uVs 17:07:22 Integrated Voltage Measurement... 17:07:31 Voltage Offset Correction: v_off_ini = 633.682 uV, v_off_fin = 632.638 uV 17:07:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.088 uVs 17:07:31 Integrated Voltage Measurement... 17:07:40 Voltage Offset Correction: v_off_ini = 616.286 uV, v_off_fin = 626.182 uV 17:07:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.451 uVs 17:07:40 Integrated Voltage Measurement... 17:07:49 Voltage Offset Correction: v_off_ini = 625.971 uV, v_off_fin = 623.886 uV 17:07:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.182 uVs 17:07:49 Integrated Voltage Measurement... 17:07:58 Voltage Offset Correction: v_off_ini = 626.170 uV, v_off_fin = 623.482 uV 17:07:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.597 uVs 17:07:58 Integrated Voltage Measurement... 17:08:07 Voltage Offset Correction: v_off_ini = 616.570 uV, v_off_fin = 611.601 uV 17:08:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 509.981 uVs 17:08:10 I2Y Average and RMS of Measurements VT = -512.548 +- 3.215 uVs I2Y = -47.154 +- 0.296 uTm^2 17:08:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:08:18 Integrated Voltage Measurement... 17:08:27 Voltage Offset Correction: v_off_ini = 628.843 uV, v_off_fin = 633.459 uV 17:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.604 uVs 17:08:27 Integrated Voltage Measurement... 17:08:36 Voltage Offset Correction: v_off_ini = 621.413 uV, v_off_fin = 631.460 uV 17:08:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 12.424 uVs 17:08:37 Integrated Voltage Measurement... 17:08:45 Voltage Offset Correction: v_off_ini = 624.061 uV, v_off_fin = 623.028 uV 17:08:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.878 uVs 17:08:46 Integrated Voltage Measurement... 17:08:54 Voltage Offset Correction: v_off_ini = 625.942 uV, v_off_fin = 627.840 uV 17:08:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.577 uVs 17:08:55 Integrated Voltage Measurement... 17:09:04 Voltage Offset Correction: v_off_ini = 630.420 uV, v_off_fin = 623.529 uV 17:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.810 uVs 17:09:04 Integrated Voltage Measurement... 17:09:13 Voltage Offset Correction: v_off_ini = 625.607 uV, v_off_fin = 625.496 uV 17:09:13 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 12.926 uVs 17:09:17 I1X Average and RMS of Measurements VT = -19.037 +- 5.097 uVs I1X = 3.807 +- 1.019 uTm 17:09:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:09:24 Integrated Voltage Measurement... 17:09:33 Voltage Offset Correction: v_off_ini = 617.078 uV, v_off_fin = 614.836 uV 17:09:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.247 uVs 17:09:33 Integrated Voltage Measurement... 17:09:42 Voltage Offset Correction: v_off_ini = 618.754 uV, v_off_fin = 639.415 uV 17:09:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.987 uVs 17:09:42 Integrated Voltage Measurement... 17:09:51 Voltage Offset Correction: v_off_ini = 629.283 uV, v_off_fin = 608.475 uV 17:09:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.988 uVs 17:09:51 Integrated Voltage Measurement... 17:10:00 Voltage Offset Correction: v_off_ini = 612.556 uV, v_off_fin = 618.178 uV 17:10:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.383 uVs 17:10:00 Integrated Voltage Measurement... 17:10:09 Voltage Offset Correction: v_off_ini = 617.424 uV, v_off_fin = 595.821 uV 17:10:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.835 uVs 17:10:09 Integrated Voltage Measurement... 17:10:18 Voltage Offset Correction: v_off_ini = 612.437 uV, v_off_fin = 611.905 uV 17:10:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.837 uVs 17:10:22 I1Y Average and RMS of Measurements VT = -174.213 +- 5.168 uVs I1Y = -34.843 +- 1.034 uTm 17:10:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:10:29 Integrated Voltage Measurement... 17:10:38 Voltage Offset Correction: v_off_ini = 614.288 uV, v_off_fin = 618.008 uV 17:10:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 13.571 uVs 17:10:39 Integrated Voltage Measurement... 17:10:48 Voltage Offset Correction: v_off_ini = 619.297 uV, v_off_fin = 625.816 uV 17:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -2.808 uVs 17:10:48 Integrated Voltage Measurement... 17:10:57 Voltage Offset Correction: v_off_ini = 628.859 uV, v_off_fin = 621.566 uV 17:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.515 uVs 17:10:57 Integrated Voltage Measurement... 17:11:06 Voltage Offset Correction: v_off_ini = 634.158 uV, v_off_fin = 641.652 uV 17:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -12.674 uVs 17:11:06 Integrated Voltage Measurement... 17:11:15 Voltage Offset Correction: v_off_ini = 617.347 uV, v_off_fin = 617.052 uV 17:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 22.492 uVs 17:11:15 Integrated Voltage Measurement... 17:11:24 Voltage Offset Correction: v_off_ini = 627.735 uV, v_off_fin = 628.466 uV 17:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -2.988 uVs 17:11:26 I2X Average and RMS of Measurements VT = 9.341 +- 2.444 uVs I2X = -0.859 +- 0.225 uTm^2 17:11:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:11:34 Integrated Voltage Measurement... 17:11:43 Voltage Offset Correction: v_off_ini = 618.482 uV, v_off_fin = 615.834 uV 17:11:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.261 uVs 17:11:43 Integrated Voltage Measurement... 17:11:52 Voltage Offset Correction: v_off_ini = 613.727 uV, v_off_fin = 611.511 uV 17:11:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.771 uVs 17:11:52 Integrated Voltage Measurement... 17:12:01 Voltage Offset Correction: v_off_ini = 617.742 uV, v_off_fin = 609.490 uV 17:12:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.020 uVs 17:12:01 Integrated Voltage Measurement... 17:12:10 Voltage Offset Correction: v_off_ini = 619.862 uV, v_off_fin = 614.655 uV 17:12:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.542 uVs 17:12:10 Integrated Voltage Measurement... 17:12:19 Voltage Offset Correction: v_off_ini = 621.325 uV, v_off_fin = 618.163 uV 17:12:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.109 uVs 17:12:19 Integrated Voltage Measurement... 17:12:28 Voltage Offset Correction: v_off_ini = 622.643 uV, v_off_fin = 620.055 uV 17:12:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.329 uVs 17:12:31 I2Y Average and RMS of Measurements VT = -510.505 +- 4.003 uVs I2Y = -46.966 +- 0.368 uTm^2 17:12:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:12:42 Integrated Voltage Measurement... 17:12:51 Voltage Offset Correction: v_off_ini = 608.526 uV, v_off_fin = 612.618 uV 17:12:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -3.006 uVs 17:12:52 Integrated Voltage Measurement... 17:13:00 Voltage Offset Correction: v_off_ini = 610.597 uV, v_off_fin = 618.015 uV 17:13:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -6.211 uVs 17:13:01 Integrated Voltage Measurement... 17:13:09 Voltage Offset Correction: v_off_ini = 626.918 uV, v_off_fin = 620.846 uV 17:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.547 uVs 17:13:10 Integrated Voltage Measurement... 17:13:19 Voltage Offset Correction: v_off_ini = 620.386 uV, v_off_fin = 636.502 uV 17:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -17.141 uVs 17:13:19 Integrated Voltage Measurement... 17:13:28 Voltage Offset Correction: v_off_ini = 633.455 uV, v_off_fin = 617.994 uV 17:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -10.847 uVs 17:13:28 Integrated Voltage Measurement... 17:13:37 Voltage Offset Correction: v_off_ini = 630.209 uV, v_off_fin = 624.081 uV 17:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.702 uVs 17:13:41 I1X Average and RMS of Measurements VT = -7.125 +- 6.902 uVs I1X = 1.425 +- 1.380 uTm 17:13:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:13:48 Integrated Voltage Measurement... 17:13:57 Voltage Offset Correction: v_off_ini = 611.979 uV, v_off_fin = 619.951 uV 17:13:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.780 uVs 17:13:57 Integrated Voltage Measurement... 17:14:06 Voltage Offset Correction: v_off_ini = 617.323 uV, v_off_fin = 629.209 uV 17:14:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.670 uVs 17:14:06 Integrated Voltage Measurement... 17:14:15 Voltage Offset Correction: v_off_ini = 632.372 uV, v_off_fin = 626.386 uV 17:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.141 uVs 17:14:15 Integrated Voltage Measurement... 17:14:24 Voltage Offset Correction: v_off_ini = 649.100 uV, v_off_fin = 654.170 uV 17:14:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.469 uVs 17:14:24 Integrated Voltage Measurement... 17:14:33 Voltage Offset Correction: v_off_ini = 624.175 uV, v_off_fin = 627.098 uV 17:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.177 uVs 17:14:33 Integrated Voltage Measurement... 17:14:42 Voltage Offset Correction: v_off_ini = 640.008 uV, v_off_fin = 638.580 uV 17:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.935 uVs 17:14:46 I1Y Average and RMS of Measurements VT = -170.029 +- 4.713 uVs I1Y = -34.006 +- 0.943 uTm 17:14:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:14:51 Integrated Voltage Measurement... 17:15:00 Voltage Offset Correction: v_off_ini = 628.379 uV, v_off_fin = 620.277 uV 17:15:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 28.839 uVs 17:15:00 Integrated Voltage Measurement... 17:15:09 Voltage Offset Correction: v_off_ini = 631.746 uV, v_off_fin = 630.052 uV 17:15:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -24.034 uVs 17:15:09 Integrated Voltage Measurement... 17:15:18 Voltage Offset Correction: v_off_ini = 621.458 uV, v_off_fin = 614.972 uV 17:15:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 24.411 uVs 17:15:18 Integrated Voltage Measurement... 17:15:27 Voltage Offset Correction: v_off_ini = 626.404 uV, v_off_fin = 625.453 uV 17:15:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -16.480 uVs 17:15:27 Integrated Voltage Measurement... 17:15:36 Voltage Offset Correction: v_off_ini = 630.025 uV, v_off_fin = 623.409 uV 17:15:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 10.485 uVs 17:15:36 Integrated Voltage Measurement... 17:15:45 Voltage Offset Correction: v_off_ini = 635.476 uV, v_off_fin = 643.472 uV 17:15:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.572 uVs 17:15:48 I2X Average and RMS of Measurements VT = 18.804 +- 7.000 uVs I2X = -1.730 +- 0.644 uTm^2 17:15:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:15:53 Integrated Voltage Measurement... 17:16:02 Voltage Offset Correction: v_off_ini = 634.105 uV, v_off_fin = 630.672 uV 17:16:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.748 uVs 17:16:02 Integrated Voltage Measurement... 17:16:11 Voltage Offset Correction: v_off_ini = 627.821 uV, v_off_fin = 636.414 uV 17:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.091 uVs 17:16:11 Integrated Voltage Measurement... 17:16:20 Voltage Offset Correction: v_off_ini = 628.044 uV, v_off_fin = 626.721 uV 17:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.617 uVs 17:16:20 Integrated Voltage Measurement... 17:16:29 Voltage Offset Correction: v_off_ini = 635.823 uV, v_off_fin = 621.517 uV 17:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.434 uVs 17:16:29 Integrated Voltage Measurement... 17:16:38 Voltage Offset Correction: v_off_ini = 629.060 uV, v_off_fin = 622.193 uV 17:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.378 uVs 17:16:38 Integrated Voltage Measurement... 17:16:47 Voltage Offset Correction: v_off_ini = 642.040 uV, v_off_fin = 642.673 uV 17:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.961 uVs 17:16:49 I2Y Average and RMS of Measurements VT = -505.205 +- 2.720 uVs I2Y = -46.479 +- 0.250 uTm^2 17:16:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:16:58 Integrated Voltage Measurement... 17:17:07 Voltage Offset Correction: v_off_ini = 647.284 uV, v_off_fin = 622.588 uV 17:17:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -23.576 uVs 17:17:07 Integrated Voltage Measurement... 17:17:16 Voltage Offset Correction: v_off_ini = 620.793 uV, v_off_fin = 624.451 uV 17:17:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -7.978 uVs 17:17:16 Integrated Voltage Measurement... 17:17:25 Voltage Offset Correction: v_off_ini = 615.211 uV, v_off_fin = 619.573 uV 17:17:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -8.885 uVs 17:17:25 Integrated Voltage Measurement... 17:17:34 Voltage Offset Correction: v_off_ini = 619.043 uV, v_off_fin = 612.240 uV 17:17:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 11.561 uVs 17:17:34 Integrated Voltage Measurement... 17:17:43 Voltage Offset Correction: v_off_ini = 609.161 uV, v_off_fin = 624.002 uV 17:17:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.182 uVs 17:17:43 Integrated Voltage Measurement... 17:17:52 Voltage Offset Correction: v_off_ini = 621.060 uV, v_off_fin = 624.228 uV 17:17:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.816 uVs 17:17:56 I1X Average and RMS of Measurements VT = -16.674 +- 10.882 uVs I1X = 3.335 +- 2.176 uTm 17:17:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:18:03 Integrated Voltage Measurement... 17:18:12 Voltage Offset Correction: v_off_ini = 624.530 uV, v_off_fin = 613.419 uV 17:18:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.937 uVs 17:18:12 Integrated Voltage Measurement... 17:18:21 Voltage Offset Correction: v_off_ini = 637.022 uV, v_off_fin = 639.360 uV 17:18:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.760 uVs 17:18:21 Integrated Voltage Measurement... 17:18:30 Voltage Offset Correction: v_off_ini = 635.645 uV, v_off_fin = 623.203 uV 17:18:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.807 uVs 17:18:30 Integrated Voltage Measurement... 17:18:39 Voltage Offset Correction: v_off_ini = 639.897 uV, v_off_fin = 646.739 uV 17:18:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.327 uVs 17:18:39 Integrated Voltage Measurement... 17:18:48 Voltage Offset Correction: v_off_ini = 630.057 uV, v_off_fin = 610.856 uV 17:18:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.358 uVs 17:18:48 Integrated Voltage Measurement... 17:18:57 Voltage Offset Correction: v_off_ini = 613.040 uV, v_off_fin = 628.168 uV 17:18:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.514 uVs 17:19:01 I1Y Average and RMS of Measurements VT = -174.117 +- 6.883 uVs I1Y = -34.823 +- 1.377 uTm 17:19:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:19:06 Integrated Voltage Measurement... 17:19:15 Voltage Offset Correction: v_off_ini = 637.906 uV, v_off_fin = 621.790 uV 17:19:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 14.561 uVs 17:19:15 Integrated Voltage Measurement... 17:19:24 Voltage Offset Correction: v_off_ini = 631.321 uV, v_off_fin = 625.616 uV 17:19:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -23.170 uVs 17:19:24 Integrated Voltage Measurement... 17:19:33 Voltage Offset Correction: v_off_ini = 616.789 uV, v_off_fin = 616.253 uV 17:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 24.351 uVs 17:19:33 Integrated Voltage Measurement... 17:19:42 Voltage Offset Correction: v_off_ini = 622.988 uV, v_off_fin = 634.289 uV 17:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -14.712 uVs 17:19:42 Integrated Voltage Measurement... 17:19:51 Voltage Offset Correction: v_off_ini = 625.571 uV, v_off_fin = 629.001 uV 17:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 35.341 uVs 17:19:51 Integrated Voltage Measurement... 17:20:00 Voltage Offset Correction: v_off_ini = 632.909 uV, v_off_fin = 643.783 uV 17:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -28.829 uVs 17:20:03 I2X Average and RMS of Measurements VT = 23.494 +- 6.081 uVs I2X = -2.161 +- 0.559 uTm^2 17:20:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:20:08 Integrated Voltage Measurement... 17:20:17 Voltage Offset Correction: v_off_ini = 628.736 uV, v_off_fin = 624.639 uV 17:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.732 uVs 17:20:17 Integrated Voltage Measurement... 17:20:26 Voltage Offset Correction: v_off_ini = 635.283 uV, v_off_fin = 637.599 uV 17:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.792 uVs 17:20:26 Integrated Voltage Measurement... 17:20:35 Voltage Offset Correction: v_off_ini = 649.251 uV, v_off_fin = 640.006 uV 17:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.233 uVs 17:20:35 Integrated Voltage Measurement... 17:20:44 Voltage Offset Correction: v_off_ini = 638.786 uV, v_off_fin = 639.510 uV 17:20:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.507 uVs 17:20:44 Integrated Voltage Measurement... 17:20:53 Voltage Offset Correction: v_off_ini = 644.870 uV, v_off_fin = 653.855 uV 17:20:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -529.348 uVs 17:20:53 Integrated Voltage Measurement... 17:21:02 Voltage Offset Correction: v_off_ini = 640.969 uV, v_off_fin = 641.533 uV 17:21:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.398 uVs 17:21:05 I2Y Average and RMS of Measurements VT = -506.835 +- 8.594 uVs I2Y = -46.629 +- 0.791 uTm^2 17:21:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:13 Integrated Voltage Measurement... 17:21:22 Voltage Offset Correction: v_off_ini = 637.241 uV, v_off_fin = 639.416 uV 17:21:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -27.856 uVs 17:21:22 Integrated Voltage Measurement... 17:21:31 Voltage Offset Correction: v_off_ini = 633.084 uV, v_off_fin = 638.657 uV 17:21:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 22.427 uVs 17:21:31 Integrated Voltage Measurement... 17:21:40 Voltage Offset Correction: v_off_ini = 648.186 uV, v_off_fin = 643.953 uV 17:21:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.387 uVs 17:21:40 Integrated Voltage Measurement... 17:21:49 Voltage Offset Correction: v_off_ini = 644.009 uV, v_off_fin = 647.734 uV 17:21:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.808 uVs 17:21:49 Integrated Voltage Measurement... 17:21:58 Voltage Offset Correction: v_off_ini = 650.712 uV, v_off_fin = 632.844 uV 17:21:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -29.982 uVs 17:21:58 Integrated Voltage Measurement... 17:22:07 Voltage Offset Correction: v_off_ini = 640.330 uV, v_off_fin = 645.266 uV 17:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 15.249 uVs 17:22:11 I1X Average and RMS of Measurements VT = -24.451 +- 1.312 uVs I1X = 4.891 +- 0.262 uTm 17:22:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:18 Integrated Voltage Measurement... 17:22:27 Voltage Offset Correction: v_off_ini = 650.689 uV, v_off_fin = 643.234 uV 17:22:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.735 uVs 17:22:27 Integrated Voltage Measurement... 17:22:36 Voltage Offset Correction: v_off_ini = 647.749 uV, v_off_fin = 671.961 uV 17:22:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.237 uVs 17:22:36 Integrated Voltage Measurement... 17:22:45 Voltage Offset Correction: v_off_ini = 658.510 uV, v_off_fin = 644.138 uV 17:22:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.758 uVs 17:22:45 Integrated Voltage Measurement... 17:22:54 Voltage Offset Correction: v_off_ini = 645.888 uV, v_off_fin = 654.881 uV 17:22:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.500 uVs 17:22:54 Integrated Voltage Measurement... 17:23:03 Voltage Offset Correction: v_off_ini = 654.309 uV, v_off_fin = 643.625 uV 17:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.958 uVs 17:23:03 Integrated Voltage Measurement... 17:23:12 Voltage Offset Correction: v_off_ini = 661.988 uV, v_off_fin = 661.516 uV 17:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.883 uVs 17:23:16 I1Y Average and RMS of Measurements VT = -176.345 +- 5.121 uVs I1Y = -35.269 +- 1.024 uTm 17:23:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:21 Integrated Voltage Measurement... 17:23:30 Voltage Offset Correction: v_off_ini = 651.096 uV, v_off_fin = 657.118 uV 17:23:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 12.702 uVs 17:23:30 Integrated Voltage Measurement... 17:23:39 Voltage Offset Correction: v_off_ini = 657.082 uV, v_off_fin = 663.299 uV 17:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.937 uVs 17:23:39 Integrated Voltage Measurement... 17:23:48 Voltage Offset Correction: v_off_ini = 665.678 uV, v_off_fin = 654.178 uV 17:23:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.914 uVs 17:23:48 Integrated Voltage Measurement... 17:23:57 Voltage Offset Correction: v_off_ini = 664.044 uV, v_off_fin = 669.133 uV 17:23:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -12.782 uVs 17:23:57 Integrated Voltage Measurement... 17:24:06 Voltage Offset Correction: v_off_ini = 666.464 uV, v_off_fin = 662.303 uV 17:24:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 6.746 uVs 17:24:07 Integrated Voltage Measurement... 17:24:15 Voltage Offset Correction: v_off_ini = 677.777 uV, v_off_fin = 673.912 uV 17:24:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -22.910 uVs 17:24:18 I2X Average and RMS of Measurements VT = 7.020 +- 6.981 uVs I2X = -0.646 +- 0.642 uTm^2 17:24:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:23 Integrated Voltage Measurement... 17:24:32 Voltage Offset Correction: v_off_ini = 669.990 uV, v_off_fin = 671.144 uV 17:24:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -523.212 uVs 17:24:32 Integrated Voltage Measurement... 17:24:41 Voltage Offset Correction: v_off_ini = 663.869 uV, v_off_fin = 669.149 uV 17:24:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.974 uVs 17:24:41 Integrated Voltage Measurement... 17:24:50 Voltage Offset Correction: v_off_ini = 673.081 uV, v_off_fin = 667.941 uV 17:24:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.711 uVs 17:24:50 Integrated Voltage Measurement... 17:24:59 Voltage Offset Correction: v_off_ini = 672.139 uV, v_off_fin = 666.908 uV 17:24:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.222 uVs 17:24:59 Integrated Voltage Measurement... 17:25:08 Voltage Offset Correction: v_off_ini = 665.230 uV, v_off_fin = 669.332 uV 17:25:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.410 uVs 17:25:08 Integrated Voltage Measurement... 17:25:17 Voltage Offset Correction: v_off_ini = 668.343 uV, v_off_fin = 668.619 uV 17:25:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.482 uVs 17:25:20 I2Y Average and RMS of Measurements VT = -511.335 +- 4.558 uVs I2Y = -47.043 +- 0.419 uTm^2 17:25:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:25:28 Integrated Voltage Measurement... 17:25:37 Voltage Offset Correction: v_off_ini = 670.358 uV, v_off_fin = 660.910 uV 17:25:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -21.490 uVs 17:25:37 Integrated Voltage Measurement... 17:25:46 Voltage Offset Correction: v_off_ini = 667.605 uV, v_off_fin = 663.223 uV 17:25:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.749 uVs 17:25:46 Integrated Voltage Measurement... 17:25:55 Voltage Offset Correction: v_off_ini = 655.316 uV, v_off_fin = 667.956 uV 17:25:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -14.523 uVs 17:25:55 Integrated Voltage Measurement... 17:26:04 Voltage Offset Correction: v_off_ini = 661.926 uV, v_off_fin = 662.635 uV 17:26:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.588 uVs 17:26:04 Integrated Voltage Measurement... 17:26:13 Voltage Offset Correction: v_off_ini = 672.633 uV, v_off_fin = 670.599 uV 17:26:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.863 uVs 17:26:13 Integrated Voltage Measurement... 17:26:22 Voltage Offset Correction: v_off_ini = 666.586 uV, v_off_fin = 676.270 uV 17:26:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 20.144 uVs 17:26:26 I1X Average and RMS of Measurements VT = -21.059 +- 7.249 uVs I1X = 4.212 +- 1.450 uTm 17:26:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:26:33 Integrated Voltage Measurement... 17:26:42 Voltage Offset Correction: v_off_ini = 680.382 uV, v_off_fin = 661.611 uV 17:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.665 uVs 17:26:42 Integrated Voltage Measurement... 17:26:51 Voltage Offset Correction: v_off_ini = 677.012 uV, v_off_fin = 702.073 uV 17:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.398 uVs 17:26:51 Integrated Voltage Measurement... 17:27:00 Voltage Offset Correction: v_off_ini = 670.392 uV, v_off_fin = 665.509 uV 17:27:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.628 uVs 17:27:00 Integrated Voltage Measurement... 17:27:09 Voltage Offset Correction: v_off_ini = 678.586 uV, v_off_fin = 681.227 uV 17:27:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.069 uVs 17:27:09 Integrated Voltage Measurement... 17:27:18 Voltage Offset Correction: v_off_ini = 663.272 uV, v_off_fin = 654.539 uV 17:27:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.735 uVs 17:27:18 Integrated Voltage Measurement... 17:27:27 Voltage Offset Correction: v_off_ini = 668.732 uV, v_off_fin = 681.263 uV 17:27:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.494 uVs 17:27:31 I1Y Average and RMS of Measurements VT = -167.832 +- 2.844 uVs I1Y = -33.566 +- 0.568 uTm 17:27:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:27:36 Integrated Voltage Measurement... 17:27:45 Voltage Offset Correction: v_off_ini = 660.712 uV, v_off_fin = 652.134 uV 17:27:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 28.180 uVs 17:27:45 Integrated Voltage Measurement... 17:27:54 Voltage Offset Correction: v_off_ini = 661.807 uV, v_off_fin = 650.525 uV 17:27:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.291 uVs 17:27:54 Integrated Voltage Measurement... 17:28:03 Voltage Offset Correction: v_off_ini = 648.010 uV, v_off_fin = 644.382 uV 17:28:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 8.660 uVs 17:28:03 Integrated Voltage Measurement... 17:28:12 Voltage Offset Correction: v_off_ini = 672.723 uV, v_off_fin = 673.980 uV 17:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.892 uVs 17:28:12 Integrated Voltage Measurement... 17:28:21 Voltage Offset Correction: v_off_ini = 670.427 uV, v_off_fin = 659.401 uV 17:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 5.494 uVs 17:28:21 Integrated Voltage Measurement... 17:28:30 Voltage Offset Correction: v_off_ini = 672.688 uV, v_off_fin = 658.634 uV 17:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.934 uVs 17:28:33 I2X Average and RMS of Measurements VT = 9.075 +- 4.178 uVs I2X = -0.835 +- 0.384 uTm^2 17:28:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:28:38 Integrated Voltage Measurement... 17:28:47 Voltage Offset Correction: v_off_ini = 664.850 uV, v_off_fin = 686.293 uV 17:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.143 uVs 17:28:47 Integrated Voltage Measurement... 17:28:56 Voltage Offset Correction: v_off_ini = 682.218 uV, v_off_fin = 685.868 uV 17:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.285 uVs 17:28:56 Integrated Voltage Measurement... 17:29:05 Voltage Offset Correction: v_off_ini = 675.098 uV, v_off_fin = 684.795 uV 17:29:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.779 uVs 17:29:05 Integrated Voltage Measurement... 17:29:14 Voltage Offset Correction: v_off_ini = 674.289 uV, v_off_fin = 670.197 uV 17:29:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.398 uVs 17:29:14 Integrated Voltage Measurement... 17:29:23 Voltage Offset Correction: v_off_ini = 660.801 uV, v_off_fin = 667.269 uV 17:29:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -489.445 uVs 17:29:23 Integrated Voltage Measurement... 17:29:32 Voltage Offset Correction: v_off_ini = 674.594 uV, v_off_fin = 678.199 uV 17:29:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.249 uVs 17:29:34 I2Y Average and RMS of Measurements VT = -507.383 +- 9.475 uVs I2Y = -46.679 +- 0.872 uTm^2 17:29:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:29:43 Integrated Voltage Measurement... 17:29:52 Voltage Offset Correction: v_off_ini = 680.084 uV, v_off_fin = 679.394 uV 17:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -24.582 uVs 17:29:52 Integrated Voltage Measurement... 17:30:01 Voltage Offset Correction: v_off_ini = 664.208 uV, v_off_fin = 667.999 uV 17:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 10.201 uVs 17:30:01 Integrated Voltage Measurement... 17:30:10 Voltage Offset Correction: v_off_ini = 665.763 uV, v_off_fin = 670.999 uV 17:30:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.864 uVs 17:30:10 Integrated Voltage Measurement... 17:30:19 Voltage Offset Correction: v_off_ini = 671.772 uV, v_off_fin = 676.073 uV 17:30:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 2.992 uVs 17:30:19 Integrated Voltage Measurement... 17:30:28 Voltage Offset Correction: v_off_ini = 680.058 uV, v_off_fin = 672.793 uV 17:30:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -13.156 uVs 17:30:28 Integrated Voltage Measurement... 17:30:37 Voltage Offset Correction: v_off_ini = 681.533 uV, v_off_fin = 695.558 uV 17:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -11.517 uVs 17:30:41 I1X Average and RMS of Measurements VT = -10.880 +- 7.216 uVs I1X = 2.176 +- 1.443 uTm 17:30:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:30:48 Integrated Voltage Measurement... 17:30:57 Voltage Offset Correction: v_off_ini = 671.164 uV, v_off_fin = 668.581 uV 17:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.897 uVs 17:30:57 Integrated Voltage Measurement... 17:31:06 Voltage Offset Correction: v_off_ini = 671.373 uV, v_off_fin = 682.811 uV 17:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 168.944 uVs 17:31:06 Integrated Voltage Measurement... 17:31:15 Voltage Offset Correction: v_off_ini = 667.173 uV, v_off_fin = 664.437 uV 17:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.784 uVs 17:31:15 Integrated Voltage Measurement... 17:31:24 Voltage Offset Correction: v_off_ini = 673.575 uV, v_off_fin = 687.984 uV 17:31:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.776 uVs 17:31:24 Integrated Voltage Measurement... 17:31:33 Voltage Offset Correction: v_off_ini = 685.467 uV, v_off_fin = 668.059 uV 17:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.379 uVs 17:31:33 Integrated Voltage Measurement... 17:31:42 Voltage Offset Correction: v_off_ini = 671.617 uV, v_off_fin = 684.045 uV 17:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.796 uVs 17:31:46 I1Y Average and RMS of Measurements VT = -178.596 +- 6.105 uVs I1Y = -35.717 +- 1.220 uTm 17:31:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:31:51 Integrated Voltage Measurement... 17:32:00 Voltage Offset Correction: v_off_ini = 666.187 uV, v_off_fin = 672.014 uV 17:32:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 20.859 uVs 17:32:00 Integrated Voltage Measurement... 17:32:09 Voltage Offset Correction: v_off_ini = 678.611 uV, v_off_fin = 692.655 uV 17:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.981 uVs 17:32:09 Integrated Voltage Measurement... 17:32:18 Voltage Offset Correction: v_off_ini = 684.570 uV, v_off_fin = 680.111 uV 17:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.410 uVs 17:32:18 Integrated Voltage Measurement... 17:32:27 Voltage Offset Correction: v_off_ini = 688.508 uV, v_off_fin = 689.359 uV 17:32:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.184 uVs 17:32:27 Integrated Voltage Measurement... 17:32:36 Voltage Offset Correction: v_off_ini = 701.766 uV, v_off_fin = 687.378 uV 17:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.986 uVs 17:32:36 Integrated Voltage Measurement... 17:32:45 Voltage Offset Correction: v_off_ini = 689.473 uV, v_off_fin = 698.691 uV 17:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -17.315 uVs 17:32:47 I2X Average and RMS of Measurements VT = 9.789 +- 4.542 uVs I2X = -0.901 +- 0.418 uTm^2 17:32:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:32:53 Integrated Voltage Measurement... 17:33:02 Voltage Offset Correction: v_off_ini = 698.445 uV, v_off_fin = 699.654 uV 17:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.267 uVs 17:33:02 Integrated Voltage Measurement... 17:33:11 Voltage Offset Correction: v_off_ini = 699.870 uV, v_off_fin = 706.006 uV 17:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 523.464 uVs 17:33:11 Integrated Voltage Measurement... 17:33:20 Voltage Offset Correction: v_off_ini = 696.533 uV, v_off_fin = 696.807 uV 17:33:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.504 uVs 17:33:20 Integrated Voltage Measurement... 17:33:29 Voltage Offset Correction: v_off_ini = 709.332 uV, v_off_fin = 701.608 uV 17:33:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.671 uVs 17:33:29 Integrated Voltage Measurement... 17:33:38 Voltage Offset Correction: v_off_ini = 694.926 uV, v_off_fin = 699.946 uV 17:33:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.050 uVs 17:33:38 Integrated Voltage Measurement... 17:33:47 Voltage Offset Correction: v_off_ini = 695.065 uV, v_off_fin = 701.624 uV 17:33:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.244 uVs 17:33:49 I2Y Average and RMS of Measurements VT = -511.200 +- 6.907 uVs I2Y = -47.030 +- 0.635 uTm^2 17:34:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:34:09 Integrated Voltage Measurement... 17:34:18 Voltage Offset Correction: v_off_ini = 713.336 uV, v_off_fin = 702.626 uV 17:34:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -44.844 uVs 17:34:18 Integrated Voltage Measurement... 17:34:27 Voltage Offset Correction: v_off_ini = 710.806 uV, v_off_fin = 717.689 uV 17:34:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.246 uVs 17:34:27 Integrated Voltage Measurement... 17:34:36 Voltage Offset Correction: v_off_ini = 712.920 uV, v_off_fin = 712.709 uV 17:34:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.405 uVs 17:34:36 Integrated Voltage Measurement... 17:34:45 Voltage Offset Correction: v_off_ini = 708.039 uV, v_off_fin = 712.567 uV 17:34:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.957 uVs 17:34:45 Integrated Voltage Measurement... 17:34:54 Voltage Offset Correction: v_off_ini = 714.276 uV, v_off_fin = 704.134 uV 17:34:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.320 uVs 17:34:54 Integrated Voltage Measurement... 17:35:03 Voltage Offset Correction: v_off_ini = 718.642 uV, v_off_fin = 731.852 uV 17:35:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.070 uVs 17:35:08 I1X Average and RMS of Measurements VT = -42.807 +- 6.478 uVs I1X = 8.562 +- 1.296 uTm 17:35:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:35:14 Integrated Voltage Measurement... 17:35:23 Voltage Offset Correction: v_off_ini = 730.303 uV, v_off_fin = 714.728 uV 17:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.944 uVs 17:35:23 Integrated Voltage Measurement... 17:35:32 Voltage Offset Correction: v_off_ini = 723.237 uV, v_off_fin = 733.937 uV 17:35:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.446 uVs 17:35:32 Integrated Voltage Measurement... 17:35:41 Voltage Offset Correction: v_off_ini = 721.086 uV, v_off_fin = 722.384 uV 17:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.947 uVs 17:35:41 Integrated Voltage Measurement... 17:35:50 Voltage Offset Correction: v_off_ini = 734.520 uV, v_off_fin = 733.061 uV 17:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.057 uVs 17:35:50 Integrated Voltage Measurement... 17:35:59 Voltage Offset Correction: v_off_ini = 719.938 uV, v_off_fin = 718.086 uV 17:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.370 uVs 17:35:59 Integrated Voltage Measurement... 17:36:08 Voltage Offset Correction: v_off_ini = 752.424 uV, v_off_fin = 746.601 uV 17:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.459 uVs 17:36:13 I1Y Average and RMS of Measurements VT = -193.204 +- 3.402 uVs I1Y = -38.641 +- 0.680 uTm 17:36:18 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:36:20 Integrated Voltage Measurement... 17:36:29 Voltage Offset Correction: v_off_ini = 717.232 uV, v_off_fin = 718.168 uV 17:36:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.144 uVs 17:36:29 Integrated Voltage Measurement... 17:36:38 Voltage Offset Correction: v_off_ini = 722.735 uV, v_off_fin = 723.692 uV 17:36:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.347 uVs 17:36:38 Integrated Voltage Measurement... 17:36:47 Voltage Offset Correction: v_off_ini = 722.864 uV, v_off_fin = 709.497 uV 17:36:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.995 uVs 17:36:47 Integrated Voltage Measurement... 17:36:56 Voltage Offset Correction: v_off_ini = 727.179 uV, v_off_fin = 720.380 uV 17:36:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.754 uVs 17:36:56 Integrated Voltage Measurement... 17:37:05 Voltage Offset Correction: v_off_ini = 727.426 uV, v_off_fin = 713.916 uV 17:37:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.808 uVs 17:37:06 Integrated Voltage Measurement... 17:37:14 Voltage Offset Correction: v_off_ini = 711.267 uV, v_off_fin = 727.588 uV 17:37:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.899 uVs 17:37:17 I2X Average and RMS of Measurements VT = -11.075 +- 9.943 uVs I2X = 1.019 +- 0.915 uTm^2 17:37:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:37:25 Integrated Voltage Measurement... 17:37:34 Voltage Offset Correction: v_off_ini = 712.730 uV, v_off_fin = 714.675 uV 17:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -523.638 uVs 17:37:34 Integrated Voltage Measurement... 17:37:43 Voltage Offset Correction: v_off_ini = 716.033 uV, v_off_fin = 722.237 uV 17:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.692 uVs 17:37:43 Integrated Voltage Measurement... 17:37:52 Voltage Offset Correction: v_off_ini = 725.754 uV, v_off_fin = 728.260 uV 17:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.041 uVs 17:37:52 Integrated Voltage Measurement... 17:38:01 Voltage Offset Correction: v_off_ini = 732.437 uV, v_off_fin = 718.460 uV 17:38:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 516.670 uVs 17:38:01 Integrated Voltage Measurement... 17:38:10 Voltage Offset Correction: v_off_ini = 715.385 uV, v_off_fin = 722.229 uV 17:38:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -525.545 uVs 17:38:10 Integrated Voltage Measurement... 17:38:19 Voltage Offset Correction: v_off_ini = 722.071 uV, v_off_fin = 717.577 uV 17:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.946 uVs 17:38:21 I2Y Average and RMS of Measurements VT = -514.755 +- 4.340 uVs I2Y = -47.358 +- 0.399 uTm^2 17:38:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:38:30 Integrated Voltage Measurement... 17:38:39 Voltage Offset Correction: v_off_ini = 721.639 uV, v_off_fin = 705.689 uV 17:38:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -52.966 uVs 17:38:39 Integrated Voltage Measurement... 17:38:48 Voltage Offset Correction: v_off_ini = 714.267 uV, v_off_fin = 704.882 uV 17:38:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.744 uVs 17:38:48 Integrated Voltage Measurement... 17:38:57 Voltage Offset Correction: v_off_ini = 704.609 uV, v_off_fin = 710.550 uV 17:38:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -16.706 uVs 17:38:57 Integrated Voltage Measurement... 17:39:06 Voltage Offset Correction: v_off_ini = 703.285 uV, v_off_fin = 708.384 uV 17:39:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.619 uVs 17:39:06 Integrated Voltage Measurement... 17:39:15 Voltage Offset Correction: v_off_ini = 707.418 uV, v_off_fin = 693.776 uV 17:39:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.033 uVs 17:39:15 Integrated Voltage Measurement... 17:39:24 Voltage Offset Correction: v_off_ini = 719.027 uV, v_off_fin = 710.675 uV 17:39:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.774 uVs 17:39:29 I1X Average and RMS of Measurements VT = -37.974 +- 6.436 uVs I1X = 7.595 +- 1.288 uTm 17:39:31 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:39:35 Integrated Voltage Measurement... 17:39:44 Voltage Offset Correction: v_off_ini = 700.659 uV, v_off_fin = 692.193 uV 17:39:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.015 uVs 17:39:44 Integrated Voltage Measurement... 17:39:53 Voltage Offset Correction: v_off_ini = 706.587 uV, v_off_fin = 731.875 uV 17:39:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.168 uVs 17:39:53 Integrated Voltage Measurement... 17:40:02 Voltage Offset Correction: v_off_ini = 696.950 uV, v_off_fin = 702.560 uV 17:40:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.450 uVs 17:40:02 Integrated Voltage Measurement... 17:40:11 Voltage Offset Correction: v_off_ini = 720.107 uV, v_off_fin = 716.756 uV 17:40:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.074 uVs 17:40:11 Integrated Voltage Measurement... 17:40:20 Voltage Offset Correction: v_off_ini = 713.824 uV, v_off_fin = 706.522 uV 17:40:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.731 uVs 17:40:20 Integrated Voltage Measurement... 17:40:29 Voltage Offset Correction: v_off_ini = 719.225 uV, v_off_fin = 719.409 uV 17:40:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.013 uVs 17:40:34 I1Y Average and RMS of Measurements VT = -195.742 +- 5.875 uVs I1Y = -39.150 +- 1.174 uTm 17:40:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:40:41 Integrated Voltage Measurement... 17:40:50 Voltage Offset Correction: v_off_ini = 702.578 uV, v_off_fin = 702.865 uV 17:40:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.704 uVs 17:40:50 Integrated Voltage Measurement... 17:40:59 Voltage Offset Correction: v_off_ini = 701.310 uV, v_off_fin = 702.177 uV 17:40:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.944 uVs 17:40:59 Integrated Voltage Measurement... 17:41:08 Voltage Offset Correction: v_off_ini = 698.881 uV, v_off_fin = 703.513 uV 17:41:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -3.114 uVs 17:41:08 Integrated Voltage Measurement... 17:41:17 Voltage Offset Correction: v_off_ini = 719.914 uV, v_off_fin = 710.771 uV 17:41:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.439 uVs 17:41:18 Integrated Voltage Measurement... 17:41:26 Voltage Offset Correction: v_off_ini = 714.334 uV, v_off_fin = 691.013 uV 17:41:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 5.185 uVs 17:41:27 Integrated Voltage Measurement... 17:41:36 Voltage Offset Correction: v_off_ini = 689.402 uV, v_off_fin = 709.550 uV 17:41:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.644 uVs 17:41:38 I2X Average and RMS of Measurements VT = -9.443 +- 4.960 uVs I2X = 0.869 +- 0.456 uTm^2 17:41:43 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:41:46 Integrated Voltage Measurement... 17:41:55 Voltage Offset Correction: v_off_ini = 695.538 uV, v_off_fin = 695.931 uV 17:41:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.931 uVs 17:41:55 Integrated Voltage Measurement... 17:42:04 Voltage Offset Correction: v_off_ini = 721.845 uV, v_off_fin = 709.428 uV 17:42:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.982 uVs 17:42:04 Integrated Voltage Measurement... 17:42:13 Voltage Offset Correction: v_off_ini = 693.596 uV, v_off_fin = 700.239 uV 17:42:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -523.268 uVs 17:42:13 Integrated Voltage Measurement... 17:42:22 Voltage Offset Correction: v_off_ini = 699.617 uV, v_off_fin = 705.041 uV 17:42:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 519.756 uVs 17:42:22 Integrated Voltage Measurement... 17:42:31 Voltage Offset Correction: v_off_ini = 690.485 uV, v_off_fin = 705.502 uV 17:42:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.927 uVs 17:42:31 Integrated Voltage Measurement... 17:42:40 Voltage Offset Correction: v_off_ini = 714.483 uV, v_off_fin = 714.680 uV 17:42:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.158 uVs 17:42:42 I2Y Average and RMS of Measurements VT = -509.337 +- 10.241 uVs I2Y = -46.859 +- 0.942 uTm^2 17:42:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:51 Integrated Voltage Measurement... 17:43:00 Voltage Offset Correction: v_off_ini = 711.855 uV, v_off_fin = 705.226 uV 17:43:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -58.689 uVs 17:43:00 Integrated Voltage Measurement... 17:43:09 Voltage Offset Correction: v_off_ini = 724.927 uV, v_off_fin = 713.154 uV 17:43:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 10.826 uVs 17:43:09 Integrated Voltage Measurement... 17:43:18 Voltage Offset Correction: v_off_ini = 708.096 uV, v_off_fin = 712.435 uV 17:43:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.175 uVs 17:43:18 Integrated Voltage Measurement... 17:43:27 Voltage Offset Correction: v_off_ini = 708.821 uV, v_off_fin = 713.508 uV 17:43:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 29.567 uVs 17:43:27 Integrated Voltage Measurement... 17:43:36 Voltage Offset Correction: v_off_ini = 704.210 uV, v_off_fin = 710.192 uV 17:43:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.520 uVs 17:43:36 Integrated Voltage Measurement... 17:43:45 Voltage Offset Correction: v_off_ini = 707.287 uV, v_off_fin = 713.498 uV 17:43:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.930 uVs 17:43:50 I1X Average and RMS of Measurements VT = -33.451 +- 1.487 uVs I1X = 6.691 +- 0.298 uTm 17:43:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:56 Integrated Voltage Measurement... 17:44:05 Voltage Offset Correction: v_off_ini = 710.212 uV, v_off_fin = 703.257 uV 17:44:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.636 uVs 17:44:05 Integrated Voltage Measurement... 17:44:14 Voltage Offset Correction: v_off_ini = 717.578 uV, v_off_fin = 720.955 uV 17:44:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.279 uVs 17:44:14 Integrated Voltage Measurement... 17:44:23 Voltage Offset Correction: v_off_ini = 718.388 uV, v_off_fin = 697.276 uV 17:44:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.339 uVs 17:44:23 Integrated Voltage Measurement... 17:44:32 Voltage Offset Correction: v_off_ini = 716.024 uV, v_off_fin = 727.388 uV 17:44:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.315 uVs 17:44:32 Integrated Voltage Measurement... 17:44:41 Voltage Offset Correction: v_off_ini = 710.148 uV, v_off_fin = 702.074 uV 17:44:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.541 uVs 17:44:41 Integrated Voltage Measurement... 17:44:50 Voltage Offset Correction: v_off_ini = 716.448 uV, v_off_fin = 726.307 uV 17:44:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.766 uVs 17:44:55 I1Y Average and RMS of Measurements VT = -185.479 +- 2.139 uVs I1Y = -37.096 +- 0.428 uTm 17:45:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:02 Integrated Voltage Measurement... 17:45:11 Voltage Offset Correction: v_off_ini = 706.618 uV, v_off_fin = 717.508 uV 17:45:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 22.543 uVs 17:45:11 Integrated Voltage Measurement... 17:45:20 Voltage Offset Correction: v_off_ini = 717.121 uV, v_off_fin = 727.162 uV 17:45:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 7.832 uVs 17:45:20 Integrated Voltage Measurement... 17:45:29 Voltage Offset Correction: v_off_ini = 725.722 uV, v_off_fin = 717.074 uV 17:45:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.187 uVs 17:45:30 Integrated Voltage Measurement... 17:45:39 Voltage Offset Correction: v_off_ini = 720.656 uV, v_off_fin = 733.368 uV 17:45:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.917 uVs 17:45:39 Integrated Voltage Measurement... 17:45:48 Voltage Offset Correction: v_off_ini = 715.187 uV, v_off_fin = 708.132 uV 17:45:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.942 uVs 17:45:48 Integrated Voltage Measurement... 17:45:57 Voltage Offset Correction: v_off_ini = 719.253 uV, v_off_fin = 731.667 uV 17:45:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.657 uVs 17:45:59 I2X Average and RMS of Measurements VT = 2.282 +- 3.700 uVs I2X = -0.210 +- 0.340 uTm^2 17:46:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:07 Integrated Voltage Measurement... 17:46:16 Voltage Offset Correction: v_off_ini = 730.843 uV, v_off_fin = 725.172 uV 17:46:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.731 uVs 17:46:16 Integrated Voltage Measurement... 17:46:25 Voltage Offset Correction: v_off_ini = 709.138 uV, v_off_fin = 708.721 uV 17:46:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.137 uVs 17:46:25 Integrated Voltage Measurement... 17:46:34 Voltage Offset Correction: v_off_ini = 709.413 uV, v_off_fin = 706.672 uV 17:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.757 uVs 17:46:34 Integrated Voltage Measurement... 17:46:43 Voltage Offset Correction: v_off_ini = 713.071 uV, v_off_fin = 713.326 uV 17:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 516.108 uVs 17:46:43 Integrated Voltage Measurement... 17:46:52 Voltage Offset Correction: v_off_ini = 711.000 uV, v_off_fin = 708.066 uV 17:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.378 uVs 17:46:52 Integrated Voltage Measurement... 17:47:01 Voltage Offset Correction: v_off_ini = 715.280 uV, v_off_fin = 705.816 uV 17:47:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 511.321 uVs 17:47:03 I2Y Average and RMS of Measurements VT = -502.905 +- 10.198 uVs I2Y = -46.268 +- 0.939 uTm^2 17:47:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:47:12 Integrated Voltage Measurement... 17:47:21 Voltage Offset Correction: v_off_ini = 708.226 uV, v_off_fin = 714.597 uV 17:47:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.324 uVs 17:47:21 Integrated Voltage Measurement... 17:47:30 Voltage Offset Correction: v_off_ini = 700.543 uV, v_off_fin = 704.162 uV 17:47:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.884 uVs 17:47:30 Integrated Voltage Measurement... 17:47:39 Voltage Offset Correction: v_off_ini = 705.607 uV, v_off_fin = 716.667 uV 17:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.691 uVs 17:47:40 Integrated Voltage Measurement... 17:47:48 Voltage Offset Correction: v_off_ini = 716.465 uV, v_off_fin = 705.544 uV 17:47:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 47.182 uVs 17:47:49 Integrated Voltage Measurement... 17:47:58 Voltage Offset Correction: v_off_ini = 712.307 uV, v_off_fin = 721.734 uV 17:47:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.027 uVs 17:47:58 Integrated Voltage Measurement... 17:48:07 Voltage Offset Correction: v_off_ini = 708.157 uV, v_off_fin = 705.230 uV 17:48:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.334 uVs 17:48:11 I1X Average and RMS of Measurements VT = -37.074 +- 7.496 uVs I1X = 7.415 +- 1.500 uTm 17:48:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:48:18 Integrated Voltage Measurement... 17:48:27 Voltage Offset Correction: v_off_ini = 707.112 uV, v_off_fin = 702.617 uV 17:48:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.319 uVs 17:48:27 Integrated Voltage Measurement... 17:48:36 Voltage Offset Correction: v_off_ini = 695.637 uV, v_off_fin = 710.723 uV 17:48:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.548 uVs 17:48:36 Integrated Voltage Measurement... 17:48:45 Voltage Offset Correction: v_off_ini = 694.077 uV, v_off_fin = 693.714 uV 17:48:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.199 uVs 17:48:45 Integrated Voltage Measurement... 17:48:54 Voltage Offset Correction: v_off_ini = 703.551 uV, v_off_fin = 722.487 uV 17:48:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.912 uVs 17:48:54 Integrated Voltage Measurement... 17:49:03 Voltage Offset Correction: v_off_ini = 711.852 uV, v_off_fin = 700.528 uV 17:49:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.589 uVs 17:49:03 Integrated Voltage Measurement... 17:49:12 Voltage Offset Correction: v_off_ini = 714.355 uV, v_off_fin = 723.031 uV 17:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.136 uVs 17:49:16 I1Y Average and RMS of Measurements VT = -185.451 +- 3.307 uVs I1Y = -37.090 +- 0.661 uTm 17:49:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:49:24 Integrated Voltage Measurement... 17:49:33 Voltage Offset Correction: v_off_ini = 709.643 uV, v_off_fin = 702.557 uV 17:49:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.705 uVs 17:49:33 Integrated Voltage Measurement... 17:49:42 Voltage Offset Correction: v_off_ini = 703.927 uV, v_off_fin = 713.297 uV 17:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.460 uVs 17:49:42 Integrated Voltage Measurement... 17:49:51 Voltage Offset Correction: v_off_ini = 711.738 uV, v_off_fin = 694.856 uV 17:49:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.201 uVs 17:49:51 Integrated Voltage Measurement... 17:50:00 Voltage Offset Correction: v_off_ini = 702.445 uV, v_off_fin = 717.253 uV 17:50:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.711 uVs 17:50:00 Integrated Voltage Measurement... 17:50:09 Voltage Offset Correction: v_off_ini = 703.521 uV, v_off_fin = 703.292 uV 17:50:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.871 uVs 17:50:09 Integrated Voltage Measurement... 17:50:18 Voltage Offset Correction: v_off_ini = 713.032 uV, v_off_fin = 726.233 uV 17:50:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.290 uVs 17:50:20 I2X Average and RMS of Measurements VT = -8.374 +- 1.917 uVs I2X = 0.770 +- 0.176 uTm^2 17:50:25 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:50:28 Integrated Voltage Measurement... 17:50:37 Voltage Offset Correction: v_off_ini = 716.111 uV, v_off_fin = 715.063 uV 17:50:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.684 uVs 17:50:37 Integrated Voltage Measurement... 17:50:46 Voltage Offset Correction: v_off_ini = 711.600 uV, v_off_fin = 712.223 uV 17:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.222 uVs 17:50:46 Integrated Voltage Measurement... 17:50:55 Voltage Offset Correction: v_off_ini = 700.848 uV, v_off_fin = 709.163 uV 17:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.021 uVs 17:50:55 Integrated Voltage Measurement... 17:51:04 Voltage Offset Correction: v_off_ini = 706.149 uV, v_off_fin = 707.698 uV 17:51:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 516.690 uVs 17:51:04 Integrated Voltage Measurement... 17:51:13 Voltage Offset Correction: v_off_ini = 716.610 uV, v_off_fin = 720.515 uV 17:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.177 uVs 17:51:13 Integrated Voltage Measurement... 17:51:22 Voltage Offset Correction: v_off_ini = 726.572 uV, v_off_fin = 730.846 uV 17:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.369 uVs 17:51:25 I2Y Average and RMS of Measurements VT = -512.027 +- 3.668 uVs I2Y = -47.106 +- 0.337 uTm^2 17:51:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:51:34 Integrated Voltage Measurement... 17:51:43 Voltage Offset Correction: v_off_ini = 716.915 uV, v_off_fin = 727.441 uV 17:51:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -37.424 uVs 17:51:43 Integrated Voltage Measurement... 17:51:52 Voltage Offset Correction: v_off_ini = 718.284 uV, v_off_fin = 730.964 uV 17:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.357 uVs 17:51:52 Integrated Voltage Measurement... 17:52:01 Voltage Offset Correction: v_off_ini = 727.868 uV, v_off_fin = 736.565 uV 17:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.373 uVs 17:52:01 Integrated Voltage Measurement... 17:52:10 Voltage Offset Correction: v_off_ini = 734.228 uV, v_off_fin = 750.578 uV 17:52:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.165 uVs 17:52:10 Integrated Voltage Measurement... 17:52:19 Voltage Offset Correction: v_off_ini = 730.445 uV, v_off_fin = 724.598 uV 17:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.573 uVs 17:52:19 Integrated Voltage Measurement... 17:52:28 Voltage Offset Correction: v_off_ini = 732.916 uV, v_off_fin = 739.762 uV 17:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.443 uVs 17:52:32 I1X Average and RMS of Measurements VT = -43.889 +- 3.536 uVs I1X = 8.778 +- 0.707 uTm 17:52:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:52:39 Integrated Voltage Measurement... 17:52:48 Voltage Offset Correction: v_off_ini = 747.554 uV, v_off_fin = 724.239 uV 17:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.034 uVs 17:52:48 Integrated Voltage Measurement... 17:52:57 Voltage Offset Correction: v_off_ini = 739.426 uV, v_off_fin = 760.706 uV 17:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.359 uVs 17:52:57 Integrated Voltage Measurement... 17:53:06 Voltage Offset Correction: v_off_ini = 754.166 uV, v_off_fin = 735.231 uV 17:53:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.794 uVs 17:53:06 Integrated Voltage Measurement... 17:53:15 Voltage Offset Correction: v_off_ini = 738.967 uV, v_off_fin = 751.137 uV 17:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.439 uVs 17:53:15 Integrated Voltage Measurement... 17:53:24 Voltage Offset Correction: v_off_ini = 744.512 uV, v_off_fin = 732.092 uV 17:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.598 uVs 17:53:24 Integrated Voltage Measurement... 17:53:33 Voltage Offset Correction: v_off_ini = 736.381 uV, v_off_fin = 748.416 uV 17:53:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.301 uVs 17:53:37 I1Y Average and RMS of Measurements VT = -176.587 +- 3.429 uVs I1Y = -35.317 +- 0.686 uTm 17:53:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:53:45 Integrated Voltage Measurement... 17:53:54 Voltage Offset Correction: v_off_ini = 732.664 uV, v_off_fin = 736.031 uV 17:53:54 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -3.539 uVs 17:53:54 Integrated Voltage Measurement... 17:54:03 Voltage Offset Correction: v_off_ini = 757.101 uV, v_off_fin = 750.005 uV 17:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.573 uVs 17:54:03 Integrated Voltage Measurement... 17:54:12 Voltage Offset Correction: v_off_ini = 739.653 uV, v_off_fin = 730.064 uV 17:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -9.518 uVs 17:54:12 Integrated Voltage Measurement... 17:54:21 Voltage Offset Correction: v_off_ini = 746.219 uV, v_off_fin = 752.643 uV 17:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.997 uVs 17:54:21 Integrated Voltage Measurement... 17:54:30 Voltage Offset Correction: v_off_ini = 745.371 uV, v_off_fin = 724.583 uV 17:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.643 uVs 17:54:30 Integrated Voltage Measurement... 17:54:39 Voltage Offset Correction: v_off_ini = 723.839 uV, v_off_fin = 747.667 uV 17:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.383 uVs 17:54:41 I2X Average and RMS of Measurements VT = -9.776 +- 2.358 uVs I2X = 0.899 +- 0.217 uTm^2 17:54:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:54:49 Integrated Voltage Measurement... 17:54:58 Voltage Offset Correction: v_off_ini = 735.655 uV, v_off_fin = 726.797 uV 17:54:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.665 uVs 17:54:58 Integrated Voltage Measurement... 17:55:07 Voltage Offset Correction: v_off_ini = 736.100 uV, v_off_fin = 731.299 uV 17:55:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.041 uVs 17:55:07 Integrated Voltage Measurement... 17:55:16 Voltage Offset Correction: v_off_ini = 740.811 uV, v_off_fin = 729.822 uV 17:55:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.205 uVs 17:55:16 Integrated Voltage Measurement... 17:55:25 Voltage Offset Correction: v_off_ini = 745.745 uV, v_off_fin = 731.357 uV 17:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 502.519 uVs 17:55:25 Integrated Voltage Measurement... 17:55:34 Voltage Offset Correction: v_off_ini = 751.525 uV, v_off_fin = 745.190 uV 17:55:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.097 uVs 17:55:34 Integrated Voltage Measurement... 17:55:43 Voltage Offset Correction: v_off_ini = 749.144 uV, v_off_fin = 735.548 uV 17:55:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 502.673 uVs 17:55:46 I2Y Average and RMS of Measurements VT = -499.867 +- 5.218 uVs I2Y = -45.988 +- 0.480 uTm^2 17:55:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:55:58 Integrated Voltage Measurement... 17:56:07 Voltage Offset Correction: v_off_ini = 730.579 uV, v_off_fin = 719.298 uV 17:56:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = 11.714 uVs 17:56:07 Integrated Voltage Measurement... 17:56:16 Voltage Offset Correction: v_off_ini = 734.403 uV, v_off_fin = 728.582 uV 17:56:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.987 uVs 17:56:16 Integrated Voltage Measurement... 17:56:25 Voltage Offset Correction: v_off_ini = 728.995 uV, v_off_fin = 729.827 uV 17:56:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.345 uVs 17:56:25 Integrated Voltage Measurement... 17:56:34 Voltage Offset Correction: v_off_ini = 729.161 uV, v_off_fin = 727.007 uV 17:56:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.451 uVs 17:56:34 Integrated Voltage Measurement... 17:56:43 Voltage Offset Correction: v_off_ini = 723.682 uV, v_off_fin = 722.203 uV 17:56:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.038 uVs 17:56:43 Integrated Voltage Measurement... 17:56:52 Voltage Offset Correction: v_off_ini = 727.224 uV, v_off_fin = 738.723 uV 17:56:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.075 uVs 17:56:56 I1X Average and RMS of Measurements VT = -16.530 +- 13.591 uVs I1X = 3.306 +- 2.718 uTm 17:56:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:57:03 Integrated Voltage Measurement... 17:57:12 Voltage Offset Correction: v_off_ini = 743.441 uV, v_off_fin = 729.750 uV 17:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.826 uVs 17:57:12 Integrated Voltage Measurement... 17:57:21 Voltage Offset Correction: v_off_ini = 739.040 uV, v_off_fin = 755.479 uV 17:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.613 uVs 17:57:21 Integrated Voltage Measurement... 17:57:30 Voltage Offset Correction: v_off_ini = 744.282 uV, v_off_fin = 741.912 uV 17:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.967 uVs 17:57:30 Integrated Voltage Measurement... 17:57:39 Voltage Offset Correction: v_off_ini = 742.924 uV, v_off_fin = 740.145 uV 17:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.721 uVs 17:57:39 Integrated Voltage Measurement... 17:57:48 Voltage Offset Correction: v_off_ini = 733.131 uV, v_off_fin = 737.439 uV 17:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.615 uVs 17:57:48 Integrated Voltage Measurement... 17:57:57 Voltage Offset Correction: v_off_ini = 749.635 uV, v_off_fin = 749.050 uV 17:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.359 uVs 17:58:01 I1Y Average and RMS of Measurements VT = -182.017 +- 4.813 uVs I1Y = -36.403 +- 0.963 uTm 17:58:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:58:06 Integrated Voltage Measurement... 17:58:15 Voltage Offset Correction: v_off_ini = 727.413 uV, v_off_fin = 728.506 uV 17:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 10.422 uVs 17:58:15 Integrated Voltage Measurement... 17:58:24 Voltage Offset Correction: v_off_ini = 736.211 uV, v_off_fin = 749.392 uV 17:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.871 uVs 17:58:24 Integrated Voltage Measurement... 17:58:33 Voltage Offset Correction: v_off_ini = 735.091 uV, v_off_fin = 733.868 uV 17:58:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 9.459 uVs 17:58:33 Integrated Voltage Measurement... 17:58:42 Voltage Offset Correction: v_off_ini = 742.277 uV, v_off_fin = 749.379 uV 17:58:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -7.205 uVs 17:58:42 Integrated Voltage Measurement... 17:58:51 Voltage Offset Correction: v_off_ini = 727.127 uV, v_off_fin = 728.873 uV 17:58:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 20.160 uVs 17:58:51 Integrated Voltage Measurement... 17:59:00 Voltage Offset Correction: v_off_ini = 737.549 uV, v_off_fin = 749.683 uV 17:59:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.790 uVs 17:59:03 I2X Average and RMS of Measurements VT = 7.361 +- 3.018 uVs I2X = -0.677 +- 0.278 uTm^2 17:59:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:59:08 Integrated Voltage Measurement... 17:59:17 Voltage Offset Correction: v_off_ini = 726.915 uV, v_off_fin = 729.296 uV 17:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.328 uVs 17:59:17 Integrated Voltage Measurement... 17:59:26 Voltage Offset Correction: v_off_ini = 723.036 uV, v_off_fin = 731.184 uV 17:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.826 uVs 17:59:26 Integrated Voltage Measurement... 17:59:35 Voltage Offset Correction: v_off_ini = 727.271 uV, v_off_fin = 716.137 uV 17:59:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.788 uVs 17:59:35 Integrated Voltage Measurement... 17:59:44 Voltage Offset Correction: v_off_ini = 721.668 uV, v_off_fin = 730.596 uV 17:59:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 498.222 uVs 17:59:44 Integrated Voltage Measurement... 17:59:53 Voltage Offset Correction: v_off_ini = 725.446 uV, v_off_fin = 719.793 uV 17:59:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.557 uVs 17:59:53 Integrated Voltage Measurement... 18:00:02 Voltage Offset Correction: v_off_ini = 720.868 uV, v_off_fin = 730.952 uV 18:00:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.198 uVs 18:00:05 I2Y Average and RMS of Measurements VT = -500.320 +- 7.039 uVs I2Y = -46.029 +- 0.648 uTm^2 18:00:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:00:13 Integrated Voltage Measurement... 18:00:22 Voltage Offset Correction: v_off_ini = 731.207 uV, v_off_fin = 730.369 uV 18:00:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.876 uVs 18:00:22 Integrated Voltage Measurement... 18:00:31 Voltage Offset Correction: v_off_ini = 737.062 uV, v_off_fin = 726.906 uV 18:00:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 20.661 uVs 18:00:31 Integrated Voltage Measurement... 18:00:40 Voltage Offset Correction: v_off_ini = 720.916 uV, v_off_fin = 727.696 uV 18:00:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -25.832 uVs 18:00:40 Integrated Voltage Measurement... 18:00:49 Voltage Offset Correction: v_off_ini = 712.551 uV, v_off_fin = 726.888 uV 18:00:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.046 uVs 18:00:49 Integrated Voltage Measurement... 18:00:58 Voltage Offset Correction: v_off_ini = 727.816 uV, v_off_fin = 728.647 uV 18:00:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.640 uVs 18:00:58 Integrated Voltage Measurement... 18:01:07 Voltage Offset Correction: v_off_ini = 723.190 uV, v_off_fin = 727.917 uV 18:01:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.536 uVs 18:01:11 I1X Average and RMS of Measurements VT = -26.765 +- 2.884 uVs I1X = 5.353 +- 0.577 uTm 18:01:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:01:18 Integrated Voltage Measurement... 18:01:27 Voltage Offset Correction: v_off_ini = 726.210 uV, v_off_fin = 720.728 uV 18:01:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.855 uVs 18:01:27 Integrated Voltage Measurement... 18:01:36 Voltage Offset Correction: v_off_ini = 731.322 uV, v_off_fin = 752.335 uV 18:01:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.801 uVs 18:01:36 Integrated Voltage Measurement... 18:01:45 Voltage Offset Correction: v_off_ini = 736.966 uV, v_off_fin = 730.750 uV 18:01:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.508 uVs 18:01:45 Integrated Voltage Measurement... 18:01:54 Voltage Offset Correction: v_off_ini = 733.616 uV, v_off_fin = 743.503 uV 18:01:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.064 uVs 18:01:54 Integrated Voltage Measurement... 18:02:03 Voltage Offset Correction: v_off_ini = 733.022 uV, v_off_fin = 729.231 uV 18:02:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.970 uVs 18:02:03 Integrated Voltage Measurement... 18:02:12 Voltage Offset Correction: v_off_ini = 739.574 uV, v_off_fin = 731.940 uV 18:02:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.827 uVs 18:02:16 I1Y Average and RMS of Measurements VT = -185.338 +- 6.588 uVs I1Y = -37.068 +- 1.318 uTm 18:02:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:02:22 Integrated Voltage Measurement... 18:02:31 Voltage Offset Correction: v_off_ini = 718.502 uV, v_off_fin = 712.832 uV 18:02:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -11.762 uVs 18:02:31 Integrated Voltage Measurement... 18:02:40 Voltage Offset Correction: v_off_ini = 737.079 uV, v_off_fin = 737.487 uV 18:02:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -3.740 uVs 18:02:40 Integrated Voltage Measurement... 18:02:49 Voltage Offset Correction: v_off_ini = 733.228 uV, v_off_fin = 730.470 uV 18:02:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.537 uVs 18:02:49 Integrated Voltage Measurement... 18:02:58 Voltage Offset Correction: v_off_ini = 732.659 uV, v_off_fin = 736.200 uV 18:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.865 uVs 18:02:58 Integrated Voltage Measurement... 18:03:07 Voltage Offset Correction: v_off_ini = 738.930 uV, v_off_fin = 733.806 uV 18:03:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -33.920 uVs 18:03:07 Integrated Voltage Measurement... 18:03:16 Voltage Offset Correction: v_off_ini = 742.831 uV, v_off_fin = 741.177 uV 18:03:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.885 uVs 18:03:18 I2X Average and RMS of Measurements VT = -8.750 +- 8.287 uVs I2X = 0.805 +- 0.762 uTm^2 18:03:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:03:23 Integrated Voltage Measurement... 18:03:32 Voltage Offset Correction: v_off_ini = 751.298 uV, v_off_fin = 751.742 uV 18:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.720 uVs 18:03:32 Integrated Voltage Measurement... 18:03:41 Voltage Offset Correction: v_off_ini = 748.089 uV, v_off_fin = 748.373 uV 18:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 516.048 uVs 18:03:41 Integrated Voltage Measurement... 18:03:50 Voltage Offset Correction: v_off_ini = 751.842 uV, v_off_fin = 756.933 uV 18:03:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.028 uVs 18:03:51 Integrated Voltage Measurement... 18:04:00 Voltage Offset Correction: v_off_ini = 748.610 uV, v_off_fin = 747.639 uV 18:04:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.211 uVs 18:04:00 Integrated Voltage Measurement... 18:04:09 Voltage Offset Correction: v_off_ini = 761.773 uV, v_off_fin = 753.015 uV 18:04:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.336 uVs 18:04:09 Integrated Voltage Measurement... 18:04:18 Voltage Offset Correction: v_off_ini = 750.366 uV, v_off_fin = 741.592 uV 18:04:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.229 uVs 18:04:20 I2Y Average and RMS of Measurements VT = -508.929 +- 0.816 uVs I2Y = -46.821 +- 0.075 uTm^2 18:04:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:04:28 Integrated Voltage Measurement... 18:04:37 Voltage Offset Correction: v_off_ini = 760.870 uV, v_off_fin = 741.101 uV 18:04:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -31.360 uVs 18:04:37 Integrated Voltage Measurement... 18:04:46 Voltage Offset Correction: v_off_ini = 746.186 uV, v_off_fin = 757.883 uV 18:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.377 uVs 18:04:46 Integrated Voltage Measurement... 18:04:55 Voltage Offset Correction: v_off_ini = 765.154 uV, v_off_fin = 762.855 uV 18:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.426 uVs 18:04:56 Integrated Voltage Measurement... 18:05:04 Voltage Offset Correction: v_off_ini = 760.548 uV, v_off_fin = 759.002 uV 18:05:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.914 uVs 18:05:05 Integrated Voltage Measurement... 18:05:14 Voltage Offset Correction: v_off_ini = 758.422 uV, v_off_fin = 740.340 uV 18:05:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.114 uVs 18:05:14 Integrated Voltage Measurement... 18:05:23 Voltage Offset Correction: v_off_ini = 751.263 uV, v_off_fin = 751.002 uV 18:05:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.760 uVs 18:05:27 I1X Average and RMS of Measurements VT = -34.325 +- 3.684 uVs I1X = 6.866 +- 0.737 uTm 18:05:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:05:34 Integrated Voltage Measurement... 18:05:43 Voltage Offset Correction: v_off_ini = 763.794 uV, v_off_fin = 755.484 uV 18:05:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.618 uVs 18:05:43 Integrated Voltage Measurement... 18:05:52 Voltage Offset Correction: v_off_ini = 760.078 uV, v_off_fin = 776.553 uV 18:05:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.648 uVs 18:05:52 Integrated Voltage Measurement... 18:06:01 Voltage Offset Correction: v_off_ini = 755.305 uV, v_off_fin = 745.865 uV 18:06:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.114 uVs 18:06:01 Integrated Voltage Measurement... 18:06:10 Voltage Offset Correction: v_off_ini = 758.034 uV, v_off_fin = 755.543 uV 18:06:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.999 uVs 18:06:10 Integrated Voltage Measurement... 18:06:19 Voltage Offset Correction: v_off_ini = 759.812 uV, v_off_fin = 743.664 uV 18:06:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.308 uVs 18:06:19 Integrated Voltage Measurement... 18:06:28 Voltage Offset Correction: v_off_ini = 754.593 uV, v_off_fin = 759.485 uV 18:06:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.205 uVs 18:06:32 I1Y Average and RMS of Measurements VT = -176.649 +- 0.327 uVs I1Y = -35.330 +- 0.065 uTm 18:06:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:37 Integrated Voltage Measurement... 18:06:46 Voltage Offset Correction: v_off_ini = 737.441 uV, v_off_fin = 739.235 uV 18:06:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -19.632 uVs 18:06:46 Integrated Voltage Measurement... 18:06:55 Voltage Offset Correction: v_off_ini = 742.810 uV, v_off_fin = 750.128 uV 18:06:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.622 uVs 18:06:55 Integrated Voltage Measurement... 18:07:04 Voltage Offset Correction: v_off_ini = 733.201 uV, v_off_fin = 737.931 uV 18:07:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.937 uVs 18:07:04 Integrated Voltage Measurement... 18:07:13 Voltage Offset Correction: v_off_ini = 755.319 uV, v_off_fin = 747.207 uV 18:07:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 9.460 uVs 18:07:13 Integrated Voltage Measurement... 18:07:22 Voltage Offset Correction: v_off_ini = 735.650 uV, v_off_fin = 726.657 uV 18:07:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 15.322 uVs 18:07:22 Integrated Voltage Measurement... 18:07:31 Voltage Offset Correction: v_off_ini = 727.063 uV, v_off_fin = 746.752 uV 18:07:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.941 uVs 18:07:33 I2X Average and RMS of Measurements VT = -6.504 +- 1.626 uVs I2X = 0.598 +- 0.150 uTm^2 18:07:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:39 Integrated Voltage Measurement... 18:07:48 Voltage Offset Correction: v_off_ini = 746.779 uV, v_off_fin = 753.642 uV 18:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -499.928 uVs 18:07:48 Integrated Voltage Measurement... 18:07:57 Voltage Offset Correction: v_off_ini = 739.880 uV, v_off_fin = 748.500 uV 18:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.921 uVs 18:07:57 Integrated Voltage Measurement... 18:08:06 Voltage Offset Correction: v_off_ini = 751.908 uV, v_off_fin = 726.038 uV 18:08:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.192 uVs 18:08:06 Integrated Voltage Measurement... 18:08:15 Voltage Offset Correction: v_off_ini = 717.142 uV, v_off_fin = 733.656 uV 18:08:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.092 uVs 18:08:15 Integrated Voltage Measurement... 18:08:24 Voltage Offset Correction: v_off_ini = 740.094 uV, v_off_fin = 724.415 uV 18:08:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.573 uVs 18:08:24 Integrated Voltage Measurement... 18:08:33 Voltage Offset Correction: v_off_ini = 740.642 uV, v_off_fin = 731.650 uV 18:08:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 516.640 uVs 18:08:35 I2Y Average and RMS of Measurements VT = -505.724 +- 4.101 uVs I2Y = -46.527 +- 0.377 uTm^2 18:08:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:08:43 Integrated Voltage Measurement... 18:08:52 Voltage Offset Correction: v_off_ini = 746.505 uV, v_off_fin = 739.449 uV 18:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.702 uVs 18:08:53 Integrated Voltage Measurement... 18:09:01 Voltage Offset Correction: v_off_ini = 737.585 uV, v_off_fin = 746.589 uV 18:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 13.361 uVs 18:09:02 Integrated Voltage Measurement... 18:09:10 Voltage Offset Correction: v_off_ini = 737.046 uV, v_off_fin = 730.538 uV 18:09:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.688 uVs 18:09:11 Integrated Voltage Measurement... 18:09:19 Voltage Offset Correction: v_off_ini = 742.001 uV, v_off_fin = 742.869 uV 18:09:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.185 uVs 18:09:20 Integrated Voltage Measurement... 18:09:28 Voltage Offset Correction: v_off_ini = 750.818 uV, v_off_fin = 744.917 uV 18:09:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.312 uVs 18:09:29 Integrated Voltage Measurement... 18:09:38 Voltage Offset Correction: v_off_ini = 729.143 uV, v_off_fin = 734.796 uV 18:09:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 52.747 uVs 18:09:42 I1X Average and RMS of Measurements VT = -39.999 +- 8.782 uVs I1X = 8.000 +- 1.757 uTm 18:09:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:09:49 Integrated Voltage Measurement... 18:09:57 Voltage Offset Correction: v_off_ini = 725.513 uV, v_off_fin = 716.582 uV 18:09:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.899 uVs 18:09:57 Integrated Voltage Measurement... 18:10:06 Voltage Offset Correction: v_off_ini = 718.298 uV, v_off_fin = 735.440 uV 18:10:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.215 uVs 18:10:07 Integrated Voltage Measurement... 18:10:15 Voltage Offset Correction: v_off_ini = 731.641 uV, v_off_fin = 725.542 uV 18:10:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.690 uVs 18:10:15 Integrated Voltage Measurement... 18:10:24 Voltage Offset Correction: v_off_ini = 734.793 uV, v_off_fin = 744.899 uV 18:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.197 uVs 18:10:24 Integrated Voltage Measurement... 18:10:33 Voltage Offset Correction: v_off_ini = 732.850 uV, v_off_fin = 730.258 uV 18:10:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.252 uVs 18:10:33 Integrated Voltage Measurement... 18:10:42 Voltage Offset Correction: v_off_ini = 723.576 uV, v_off_fin = 741.265 uV 18:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.385 uVs 18:10:47 I1Y Average and RMS of Measurements VT = -179.106 +- 2.814 uVs I1Y = -35.820 +- 0.564 uTm 18:10:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:10:52 Integrated Voltage Measurement... 18:11:01 Voltage Offset Correction: v_off_ini = 713.294 uV, v_off_fin = 708.298 uV 18:11:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 18.887 uVs 18:11:01 Integrated Voltage Measurement... 18:11:10 Voltage Offset Correction: v_off_ini = 712.934 uV, v_off_fin = 725.618 uV 18:11:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.600 uVs 18:11:10 Integrated Voltage Measurement... 18:11:19 Voltage Offset Correction: v_off_ini = 722.409 uV, v_off_fin = 709.949 uV 18:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.123 uVs 18:11:19 Integrated Voltage Measurement... 18:11:28 Voltage Offset Correction: v_off_ini = 715.760 uV, v_off_fin = 722.588 uV 18:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.859 uVs 18:11:28 Integrated Voltage Measurement... 18:11:37 Voltage Offset Correction: v_off_ini = 709.071 uV, v_off_fin = 703.182 uV 18:11:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.305 uVs 18:11:37 Integrated Voltage Measurement... 18:11:46 Voltage Offset Correction: v_off_ini = 728.816 uV, v_off_fin = 713.449 uV 18:11:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.024 uVs 18:11:48 I2X Average and RMS of Measurements VT = -0.043 +- 4.544 uVs I2X = 0.004 +- 0.418 uTm^2 18:11:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:11:53 Integrated Voltage Measurement... 18:12:02 Voltage Offset Correction: v_off_ini = 707.299 uV, v_off_fin = 692.761 uV 18:12:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -526.113 uVs 18:12:02 Integrated Voltage Measurement... 18:12:11 Voltage Offset Correction: v_off_ini = 682.657 uV, v_off_fin = 683.011 uV 18:12:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.560 uVs 18:12:12 Integrated Voltage Measurement... 18:12:20 Voltage Offset Correction: v_off_ini = 691.287 uV, v_off_fin = 705.779 uV 18:12:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -525.326 uVs 18:12:21 Integrated Voltage Measurement... 18:12:30 Voltage Offset Correction: v_off_ini = 716.041 uV, v_off_fin = 704.932 uV 18:12:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.973 uVs 18:12:30 Integrated Voltage Measurement... 18:12:39 Voltage Offset Correction: v_off_ini = 725.067 uV, v_off_fin = 697.888 uV 18:12:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.006 uVs 18:12:39 Integrated Voltage Measurement... 18:12:48 Voltage Offset Correction: v_off_ini = 698.918 uV, v_off_fin = 696.010 uV 18:12:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.636 uVs 18:12:50 I2Y Average and RMS of Measurements VT = -512.436 +- 6.354 uVs I2Y = -47.144 +- 0.585 uTm^2 18:12:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:12:58 Integrated Voltage Measurement... 18:13:07 Voltage Offset Correction: v_off_ini = 716.694 uV, v_off_fin = 713.243 uV 18:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.729 uVs 18:13:07 Integrated Voltage Measurement... 18:13:16 Voltage Offset Correction: v_off_ini = 705.956 uV, v_off_fin = 705.625 uV 18:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.054 uVs 18:13:16 Integrated Voltage Measurement... 18:13:25 Voltage Offset Correction: v_off_ini = 701.160 uV, v_off_fin = 700.257 uV 18:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -5.233 uVs 18:13:25 Integrated Voltage Measurement... 18:13:34 Voltage Offset Correction: v_off_ini = 707.477 uV, v_off_fin = 715.408 uV 18:13:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.585 uVs 18:13:34 Integrated Voltage Measurement... 18:13:43 Voltage Offset Correction: v_off_ini = 702.312 uV, v_off_fin = 691.222 uV 18:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.228 uVs 18:13:43 Integrated Voltage Measurement... 18:13:52 Voltage Offset Correction: v_off_ini = 684.999 uV, v_off_fin = 690.940 uV 18:13:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.528 uVs 18:13:57 I1X Average and RMS of Measurements VT = -26.060 +- 6.709 uVs I1X = 5.212 +- 1.342 uTm 18:13:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:14:03 Integrated Voltage Measurement... 18:14:12 Voltage Offset Correction: v_off_ini = 693.312 uV, v_off_fin = 679.486 uV 18:14:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.971 uVs 18:14:12 Integrated Voltage Measurement... 18:14:21 Voltage Offset Correction: v_off_ini = 700.686 uV, v_off_fin = 708.060 uV 18:14:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.893 uVs 18:14:21 Integrated Voltage Measurement... 18:14:30 Voltage Offset Correction: v_off_ini = 698.497 uV, v_off_fin = 700.228 uV 18:14:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.844 uVs 18:14:30 Integrated Voltage Measurement... 18:14:39 Voltage Offset Correction: v_off_ini = 703.314 uV, v_off_fin = 723.666 uV 18:14:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.060 uVs 18:14:39 Integrated Voltage Measurement... 18:14:48 Voltage Offset Correction: v_off_ini = 719.162 uV, v_off_fin = 704.099 uV 18:14:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.092 uVs 18:14:48 Integrated Voltage Measurement... 18:14:57 Voltage Offset Correction: v_off_ini = 710.404 uV, v_off_fin = 714.707 uV 18:14:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.696 uVs 18:15:01 I1Y Average and RMS of Measurements VT = -185.426 +- 4.621 uVs I1Y = -37.082 +- 0.924 uTm 18:15:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:15:07 Integrated Voltage Measurement... 18:15:16 Voltage Offset Correction: v_off_ini = 724.677 uV, v_off_fin = 711.456 uV 18:15:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.533 uVs 18:15:16 Integrated Voltage Measurement... 18:15:25 Voltage Offset Correction: v_off_ini = 716.182 uV, v_off_fin = 723.851 uV 18:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.436 uVs 18:15:25 Integrated Voltage Measurement... 18:15:34 Voltage Offset Correction: v_off_ini = 728.331 uV, v_off_fin = 706.280 uV 18:15:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -16.899 uVs 18:15:34 Integrated Voltage Measurement... 18:15:43 Voltage Offset Correction: v_off_ini = 728.990 uV, v_off_fin = 729.944 uV 18:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.566 uVs 18:15:43 Integrated Voltage Measurement... 18:15:52 Voltage Offset Correction: v_off_ini = 726.481 uV, v_off_fin = 720.419 uV 18:15:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 4.277 uVs 18:15:52 Integrated Voltage Measurement... 18:16:01 Voltage Offset Correction: v_off_ini = 735.699 uV, v_off_fin = 732.638 uV 18:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.600 uVs 18:16:03 I2X Average and RMS of Measurements VT = -9.271 +- 9.176 uVs I2X = 0.853 +- 0.844 uTm^2 18:16:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:16:08 Integrated Voltage Measurement... 18:16:17 Voltage Offset Correction: v_off_ini = 727.545 uV, v_off_fin = 725.378 uV 18:16:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.711 uVs 18:16:17 Integrated Voltage Measurement... 18:16:26 Voltage Offset Correction: v_off_ini = 730.471 uV, v_off_fin = 731.832 uV 18:16:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.817 uVs 18:16:26 Integrated Voltage Measurement... 18:16:35 Voltage Offset Correction: v_off_ini = 739.615 uV, v_off_fin = 720.835 uV 18:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.590 uVs 18:16:35 Integrated Voltage Measurement... 18:16:44 Voltage Offset Correction: v_off_ini = 729.346 uV, v_off_fin = 725.398 uV 18:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.320 uVs 18:16:44 Integrated Voltage Measurement... 18:16:53 Voltage Offset Correction: v_off_ini = 737.450 uV, v_off_fin = 726.113 uV 18:16:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.698 uVs 18:16:53 Integrated Voltage Measurement... 18:17:02 Voltage Offset Correction: v_off_ini = 733.302 uV, v_off_fin = 744.846 uV 18:17:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.894 uVs 18:17:05 I2Y Average and RMS of Measurements VT = -507.171 +- 8.149 uVs I2Y = -46.660 +- 0.750 uTm^2 18:17:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:17:26 Integrated Voltage Measurement... 18:17:35 Voltage Offset Correction: v_off_ini = 748.781 uV, v_off_fin = 734.745 uV 18:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -53.226 uVs 18:17:35 Integrated Voltage Measurement... 18:17:44 Voltage Offset Correction: v_off_ini = 759.368 uV, v_off_fin = 748.847 uV 18:17:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.539 uVs 18:17:44 Integrated Voltage Measurement... 18:17:53 Voltage Offset Correction: v_off_ini = 745.717 uV, v_off_fin = 735.499 uV 18:17:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -45.648 uVs 18:17:53 Integrated Voltage Measurement... 18:18:02 Voltage Offset Correction: v_off_ini = 726.523 uV, v_off_fin = 729.845 uV 18:18:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 56.463 uVs 18:18:02 Integrated Voltage Measurement... 18:18:11 Voltage Offset Correction: v_off_ini = 739.645 uV, v_off_fin = 737.380 uV 18:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.191 uVs 18:18:11 Integrated Voltage Measurement... 18:18:20 Voltage Offset Correction: v_off_ini = 730.586 uV, v_off_fin = 741.090 uV 18:18:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.784 uVs 18:18:24 I1X Average and RMS of Measurements VT = -49.975 +- 5.809 uVs I1X = 9.996 +- 1.162 uTm 18:18:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:18:31 Integrated Voltage Measurement... 18:18:40 Voltage Offset Correction: v_off_ini = 724.402 uV, v_off_fin = 733.386 uV 18:18:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.371 uVs 18:18:40 Integrated Voltage Measurement... 18:18:49 Voltage Offset Correction: v_off_ini = 746.332 uV, v_off_fin = 756.267 uV 18:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.810 uVs 18:18:49 Integrated Voltage Measurement... 18:18:58 Voltage Offset Correction: v_off_ini = 739.444 uV, v_off_fin = 722.463 uV 18:18:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.786 uVs 18:18:58 Integrated Voltage Measurement... 18:19:07 Voltage Offset Correction: v_off_ini = 741.107 uV, v_off_fin = 735.492 uV 18:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.029 uVs 18:19:07 Integrated Voltage Measurement... 18:19:16 Voltage Offset Correction: v_off_ini = 726.173 uV, v_off_fin = 725.435 uV 18:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.029 uVs 18:19:16 Integrated Voltage Measurement... 18:19:25 Voltage Offset Correction: v_off_ini = 737.799 uV, v_off_fin = 747.251 uV 18:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.332 uVs 18:19:29 I1Y Average and RMS of Measurements VT = -190.559 +- 3.199 uVs I1Y = -38.112 +- 0.640 uTm 18:19:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:19:37 Integrated Voltage Measurement... 18:19:46 Voltage Offset Correction: v_off_ini = 719.997 uV, v_off_fin = 724.099 uV 18:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.137 uVs 18:19:46 Integrated Voltage Measurement... 18:19:55 Voltage Offset Correction: v_off_ini = 731.447 uV, v_off_fin = 741.831 uV 18:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.603 uVs 18:19:55 Integrated Voltage Measurement... 18:20:04 Voltage Offset Correction: v_off_ini = 748.756 uV, v_off_fin = 739.529 uV 18:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.068 uVs 18:20:04 Integrated Voltage Measurement... 18:20:13 Voltage Offset Correction: v_off_ini = 748.980 uV, v_off_fin = 752.785 uV 18:20:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.952 uVs 18:20:13 Integrated Voltage Measurement... 18:20:22 Voltage Offset Correction: v_off_ini = 737.871 uV, v_off_fin = 726.474 uV 18:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.015 uVs 18:20:22 Integrated Voltage Measurement... 18:20:31 Voltage Offset Correction: v_off_ini = 731.987 uV, v_off_fin = 744.184 uV 18:20:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.315 uVs 18:20:33 I2X Average and RMS of Measurements VT = -30.182 +- 2.405 uVs I2X = 2.777 +- 0.221 uTm^2 18:20:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:20:41 Integrated Voltage Measurement... 18:20:50 Voltage Offset Correction: v_off_ini = 739.608 uV, v_off_fin = 739.535 uV 18:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.449 uVs 18:20:50 Integrated Voltage Measurement... 18:20:59 Voltage Offset Correction: v_off_ini = 743.686 uV, v_off_fin = 738.455 uV 18:20:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 509.618 uVs 18:20:59 Integrated Voltage Measurement... 18:21:08 Voltage Offset Correction: v_off_ini = 733.409 uV, v_off_fin = 737.362 uV 18:21:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.843 uVs 18:21:08 Integrated Voltage Measurement... 18:21:17 Voltage Offset Correction: v_off_ini = 747.241 uV, v_off_fin = 741.922 uV 18:21:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.278 uVs 18:21:17 Integrated Voltage Measurement... 18:21:26 Voltage Offset Correction: v_off_ini = 745.497 uV, v_off_fin = 739.714 uV 18:21:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -505.143 uVs 18:21:26 Integrated Voltage Measurement... 18:21:35 Voltage Offset Correction: v_off_ini = 742.600 uV, v_off_fin = 737.861 uV 18:21:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.881 uVs 18:21:38 I2Y Average and RMS of Measurements VT = -503.369 +- 6.484 uVs I2Y = -46.310 +- 0.597 uTm^2 18:21:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:21:47 Integrated Voltage Measurement... 18:21:56 Voltage Offset Correction: v_off_ini = 730.126 uV, v_off_fin = 733.581 uV 18:21:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.711 uVs 18:21:56 Integrated Voltage Measurement... 18:22:05 Voltage Offset Correction: v_off_ini = 754.178 uV, v_off_fin = 741.190 uV 18:22:05 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 44.255 uVs 18:22:05 Integrated Voltage Measurement... 18:22:14 Voltage Offset Correction: v_off_ini = 751.008 uV, v_off_fin = 737.449 uV 18:22:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.562 uVs 18:22:14 Integrated Voltage Measurement... 18:22:23 Voltage Offset Correction: v_off_ini = 734.165 uV, v_off_fin = 735.389 uV 18:22:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.503 uVs 18:22:23 Integrated Voltage Measurement... 18:22:32 Voltage Offset Correction: v_off_ini = 737.637 uV, v_off_fin = 741.722 uV 18:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.593 uVs 18:22:32 Integrated Voltage Measurement... 18:22:41 Voltage Offset Correction: v_off_ini = 745.628 uV, v_off_fin = 760.195 uV 18:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.045 uVs 18:22:45 I1X Average and RMS of Measurements VT = -52.112 +- 1.007 uVs I1X = 10.423 +- 0.201 uTm 18:22:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:22:52 Integrated Voltage Measurement... 18:23:01 Voltage Offset Correction: v_off_ini = 742.796 uV, v_off_fin = 735.381 uV 18:23:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.870 uVs 18:23:01 Integrated Voltage Measurement... 18:23:10 Voltage Offset Correction: v_off_ini = 736.005 uV, v_off_fin = 740.487 uV 18:23:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.218 uVs 18:23:10 Integrated Voltage Measurement... 18:23:19 Voltage Offset Correction: v_off_ini = 727.659 uV, v_off_fin = 734.486 uV 18:23:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.516 uVs 18:23:19 Integrated Voltage Measurement... 18:23:28 Voltage Offset Correction: v_off_ini = 733.356 uV, v_off_fin = 745.561 uV 18:23:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.333 uVs 18:23:28 Integrated Voltage Measurement... 18:23:37 Voltage Offset Correction: v_off_ini = 739.089 uV, v_off_fin = 741.138 uV 18:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.728 uVs 18:23:37 Integrated Voltage Measurement... 18:23:46 Voltage Offset Correction: v_off_ini = 744.822 uV, v_off_fin = 752.665 uV 18:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.348 uVs 18:23:50 I1Y Average and RMS of Measurements VT = -197.835 +- 6.003 uVs I1Y = -39.567 +- 1.201 uTm 18:23:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:23:58 Integrated Voltage Measurement... 18:24:06 Voltage Offset Correction: v_off_ini = 757.128 uV, v_off_fin = 740.468 uV 18:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.519 uVs 18:24:07 Integrated Voltage Measurement... 18:24:16 Voltage Offset Correction: v_off_ini = 754.878 uV, v_off_fin = 737.381 uV 18:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.192 uVs 18:24:16 Integrated Voltage Measurement... 18:24:25 Voltage Offset Correction: v_off_ini = 740.386 uV, v_off_fin = 731.874 uV 18:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.617 uVs 18:24:25 Integrated Voltage Measurement... 18:24:34 Voltage Offset Correction: v_off_ini = 743.141 uV, v_off_fin = 744.261 uV 18:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.398 uVs 18:24:34 Integrated Voltage Measurement... 18:24:43 Voltage Offset Correction: v_off_ini = 745.719 uV, v_off_fin = 736.526 uV 18:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.173 uVs 18:24:43 Integrated Voltage Measurement... 18:24:52 Voltage Offset Correction: v_off_ini = 745.333 uV, v_off_fin = 755.663 uV 18:24:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.412 uVs 18:24:54 I2X Average and RMS of Measurements VT = -26.885 +- 7.167 uVs I2X = 2.473 +- 0.659 uTm^2 18:24:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:25:02 Integrated Voltage Measurement... 18:25:11 Voltage Offset Correction: v_off_ini = 745.860 uV, v_off_fin = 754.823 uV 18:25:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.790 uVs 18:25:11 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 747.092 uV, v_off_fin = 756.537 uV 18:25:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.673 uVs 18:25:20 Integrated Voltage Measurement... 18:25:29 Voltage Offset Correction: v_off_ini = 754.158 uV, v_off_fin = 750.589 uV 18:25:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -505.749 uVs 18:25:29 Integrated Voltage Measurement... 18:25:38 Voltage Offset Correction: v_off_ini = 770.704 uV, v_off_fin = 761.101 uV 18:25:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.307 uVs 18:25:38 Integrated Voltage Measurement... 18:25:47 Voltage Offset Correction: v_off_ini = 752.052 uV, v_off_fin = 746.355 uV 18:25:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.832 uVs 18:25:47 Integrated Voltage Measurement... 18:25:56 Voltage Offset Correction: v_off_ini = 736.505 uV, v_off_fin = 744.679 uV 18:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 541.316 uVs 18:25:58 I2Y Average and RMS of Measurements VT = -506.778 +- 10.463 uVs I2Y = -46.624 +- 0.963 uTm^2 18:26:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:26:07 Integrated Voltage Measurement... 18:26:16 Voltage Offset Correction: v_off_ini = 762.148 uV, v_off_fin = 748.151 uV 18:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.906 uVs 18:26:16 Integrated Voltage Measurement... 18:26:25 Voltage Offset Correction: v_off_ini = 759.003 uV, v_off_fin = 755.044 uV 18:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 48.873 uVs 18:26:25 Integrated Voltage Measurement... 18:26:34 Voltage Offset Correction: v_off_ini = 761.231 uV, v_off_fin = 738.387 uV 18:26:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.804 uVs 18:26:34 Integrated Voltage Measurement... 18:26:43 Voltage Offset Correction: v_off_ini = 751.002 uV, v_off_fin = 764.754 uV 18:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.731 uVs 18:26:44 Integrated Voltage Measurement... 18:26:52 Voltage Offset Correction: v_off_ini = 761.943 uV, v_off_fin = 755.519 uV 18:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.223 uVs 18:26:53 Integrated Voltage Measurement... 18:27:01 Voltage Offset Correction: v_off_ini = 755.206 uV, v_off_fin = 756.663 uV 18:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.931 uVs 18:27:06 I1X Average and RMS of Measurements VT = -62.911 +- 8.250 uVs I1X = 12.583 +- 1.650 uTm 18:27:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:27:13 Integrated Voltage Measurement... 18:27:21 Voltage Offset Correction: v_off_ini = 744.924 uV, v_off_fin = 739.660 uV 18:27:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.845 uVs 18:27:22 Integrated Voltage Measurement... 18:27:30 Voltage Offset Correction: v_off_ini = 744.364 uV, v_off_fin = 750.090 uV 18:27:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.796 uVs 18:27:31 Integrated Voltage Measurement... 18:27:39 Voltage Offset Correction: v_off_ini = 759.354 uV, v_off_fin = 749.128 uV 18:27:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.869 uVs 18:27:40 Integrated Voltage Measurement... 18:27:48 Voltage Offset Correction: v_off_ini = 750.594 uV, v_off_fin = 758.268 uV 18:27:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.057 uVs 18:27:49 Integrated Voltage Measurement... 18:27:58 Voltage Offset Correction: v_off_ini = 762.356 uV, v_off_fin = 760.390 uV 18:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.517 uVs 18:27:58 Integrated Voltage Measurement... 18:28:07 Voltage Offset Correction: v_off_ini = 752.993 uV, v_off_fin = 752.458 uV 18:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.858 uVs 18:28:11 I1Y Average and RMS of Measurements VT = -188.824 +- 5.164 uVs I1Y = -37.765 +- 1.033 uTm 18:28:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:28:18 Integrated Voltage Measurement... 18:28:27 Voltage Offset Correction: v_off_ini = 756.675 uV, v_off_fin = 755.824 uV 18:28:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.906 uVs 18:28:28 Integrated Voltage Measurement... 18:28:37 Voltage Offset Correction: v_off_ini = 764.216 uV, v_off_fin = 756.914 uV 18:28:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.857 uVs 18:28:37 Integrated Voltage Measurement... 18:28:46 Voltage Offset Correction: v_off_ini = 763.118 uV, v_off_fin = 756.404 uV 18:28:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.061 uVs 18:28:46 Integrated Voltage Measurement... 18:28:55 Voltage Offset Correction: v_off_ini = 753.054 uV, v_off_fin = 766.631 uV 18:28:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.040 uVs 18:28:55 Integrated Voltage Measurement... 18:29:04 Voltage Offset Correction: v_off_ini = 759.055 uV, v_off_fin = 754.368 uV 18:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.291 uVs 18:29:04 Integrated Voltage Measurement... 18:29:13 Voltage Offset Correction: v_off_ini = 753.010 uV, v_off_fin = 764.173 uV 18:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.222 uVs 18:29:15 I2X Average and RMS of Measurements VT = -31.063 +- 0.847 uVs I2X = 2.858 +- 0.078 uTm^2 18:29:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:29:23 Integrated Voltage Measurement... 18:29:32 Voltage Offset Correction: v_off_ini = 753.665 uV, v_off_fin = 746.867 uV 18:29:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.364 uVs 18:29:32 Integrated Voltage Measurement... 18:29:41 Voltage Offset Correction: v_off_ini = 745.539 uV, v_off_fin = 746.315 uV 18:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.234 uVs 18:29:41 Integrated Voltage Measurement... 18:29:50 Voltage Offset Correction: v_off_ini = 753.133 uV, v_off_fin = 746.363 uV 18:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.927 uVs 18:29:50 Integrated Voltage Measurement... 18:29:59 Voltage Offset Correction: v_off_ini = 741.359 uV, v_off_fin = 747.061 uV 18:29:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 519.567 uVs 18:29:59 Integrated Voltage Measurement... 18:30:08 Voltage Offset Correction: v_off_ini = 755.655 uV, v_off_fin = 768.632 uV 18:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.372 uVs 18:30:08 Integrated Voltage Measurement... 18:30:17 Voltage Offset Correction: v_off_ini = 766.046 uV, v_off_fin = 763.282 uV 18:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.563 uVs 18:30:20 I2Y Average and RMS of Measurements VT = -498.338 +- 11.499 uVs I2Y = -45.847 +- 1.058 uTm^2 18:30:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:30:28 Integrated Voltage Measurement... 18:30:37 Voltage Offset Correction: v_off_ini = 771.277 uV, v_off_fin = 766.633 uV 18:30:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.856 uVs 18:30:37 Integrated Voltage Measurement... 18:30:46 Voltage Offset Correction: v_off_ini = 766.963 uV, v_off_fin = 753.565 uV 18:30:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.388 uVs 18:30:47 Integrated Voltage Measurement... 18:30:55 Voltage Offset Correction: v_off_ini = 746.917 uV, v_off_fin = 748.815 uV 18:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.544 uVs 18:30:56 Integrated Voltage Measurement... 18:31:04 Voltage Offset Correction: v_off_ini = 749.208 uV, v_off_fin = 748.314 uV 18:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.682 uVs 18:31:05 Integrated Voltage Measurement... 18:31:14 Voltage Offset Correction: v_off_ini = 741.029 uV, v_off_fin = 745.197 uV 18:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.576 uVs 18:31:14 Integrated Voltage Measurement... 18:31:23 Voltage Offset Correction: v_off_ini = 762.566 uV, v_off_fin = 755.914 uV 18:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.360 uVs 18:31:27 I1X Average and RMS of Measurements VT = -50.567 +- 8.095 uVs I1X = 10.113 +- 1.619 uTm 18:31:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:31:34 Integrated Voltage Measurement... 18:31:43 Voltage Offset Correction: v_off_ini = 752.831 uV, v_off_fin = 748.702 uV 18:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.880 uVs 18:31:43 Integrated Voltage Measurement... 18:31:52 Voltage Offset Correction: v_off_ini = 765.037 uV, v_off_fin = 773.564 uV 18:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.775 uVs 18:31:52 Integrated Voltage Measurement... 18:32:01 Voltage Offset Correction: v_off_ini = 764.262 uV, v_off_fin = 760.605 uV 18:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.848 uVs 18:32:01 Integrated Voltage Measurement... 18:32:10 Voltage Offset Correction: v_off_ini = 759.093 uV, v_off_fin = 768.843 uV 18:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.720 uVs 18:32:10 Integrated Voltage Measurement... 18:32:19 Voltage Offset Correction: v_off_ini = 751.136 uV, v_off_fin = 751.837 uV 18:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.350 uVs 18:32:19 Integrated Voltage Measurement... 18:32:28 Voltage Offset Correction: v_off_ini = 764.390 uV, v_off_fin = 767.002 uV 18:32:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.106 uVs 18:32:32 I1Y Average and RMS of Measurements VT = -190.446 +- 1.613 uVs I1Y = -38.090 +- 0.322 uTm 18:32:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:32:40 Integrated Voltage Measurement... 18:32:49 Voltage Offset Correction: v_off_ini = 754.433 uV, v_off_fin = 749.889 uV 18:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.065 uVs 18:32:49 Integrated Voltage Measurement... 18:32:58 Voltage Offset Correction: v_off_ini = 774.342 uV, v_off_fin = 782.712 uV 18:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.276 uVs 18:32:58 Integrated Voltage Measurement... 18:33:07 Voltage Offset Correction: v_off_ini = 767.280 uV, v_off_fin = 764.305 uV 18:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.364 uVs 18:33:07 Integrated Voltage Measurement... 18:33:16 Voltage Offset Correction: v_off_ini = 768.939 uV, v_off_fin = 772.456 uV 18:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.453 uVs 18:33:16 Integrated Voltage Measurement... 18:33:25 Voltage Offset Correction: v_off_ini = 773.644 uV, v_off_fin = 757.996 uV 18:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.258 uVs 18:33:25 Integrated Voltage Measurement... 18:33:34 Voltage Offset Correction: v_off_ini = 764.539 uV, v_off_fin = 770.852 uV 18:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.973 uVs 18:33:36 I2X Average and RMS of Measurements VT = -28.898 +- 8.557 uVs I2X = 2.659 +- 0.787 uTm^2 18:33:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:33:44 Integrated Voltage Measurement... 18:33:53 Voltage Offset Correction: v_off_ini = 778.108 uV, v_off_fin = 772.287 uV 18:33:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.737 uVs 18:33:53 Integrated Voltage Measurement... 18:34:02 Voltage Offset Correction: v_off_ini = 777.263 uV, v_off_fin = 775.910 uV 18:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.064 uVs 18:34:02 Integrated Voltage Measurement... 18:34:11 Voltage Offset Correction: v_off_ini = 779.187 uV, v_off_fin = 761.794 uV 18:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.485 uVs 18:34:11 Integrated Voltage Measurement... 18:34:20 Voltage Offset Correction: v_off_ini = 756.724 uV, v_off_fin = 761.113 uV 18:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.016 uVs 18:34:20 Integrated Voltage Measurement... 18:34:29 Voltage Offset Correction: v_off_ini = 756.302 uV, v_off_fin = 766.069 uV 18:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.585 uVs 18:34:29 Integrated Voltage Measurement... 18:34:38 Voltage Offset Correction: v_off_ini = 766.534 uV, v_off_fin = 754.273 uV 18:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.284 uVs 18:34:41 I2Y Average and RMS of Measurements VT = -499.528 +- 4.187 uVs I2Y = -45.957 +- 0.385 uTm^2 18:34:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:34:50 Integrated Voltage Measurement... 18:34:59 Voltage Offset Correction: v_off_ini = 759.250 uV, v_off_fin = 750.607 uV 18:34:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.830 uVs 18:34:59 Integrated Voltage Measurement... 18:35:08 Voltage Offset Correction: v_off_ini = 753.271 uV, v_off_fin = 751.925 uV 18:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.440 uVs 18:35:08 Integrated Voltage Measurement... 18:35:17 Voltage Offset Correction: v_off_ini = 752.526 uV, v_off_fin = 754.713 uV 18:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.070 uVs 18:35:17 Integrated Voltage Measurement... 18:35:26 Voltage Offset Correction: v_off_ini = 757.654 uV, v_off_fin = 758.769 uV 18:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.229 uVs 18:35:26 Integrated Voltage Measurement... 18:35:35 Voltage Offset Correction: v_off_ini = 742.836 uV, v_off_fin = 745.628 uV 18:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.944 uVs 18:35:35 Integrated Voltage Measurement... 18:35:44 Voltage Offset Correction: v_off_ini = 743.097 uV, v_off_fin = 756.826 uV 18:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.437 uVs 18:35:48 I1X Average and RMS of Measurements VT = -59.492 +- 9.274 uVs I1X = 11.899 +- 1.856 uTm 18:35:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:35:55 Integrated Voltage Measurement... 18:36:04 Voltage Offset Correction: v_off_ini = 756.848 uV, v_off_fin = 749.936 uV 18:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.815 uVs 18:36:04 Integrated Voltage Measurement... 18:36:13 Voltage Offset Correction: v_off_ini = 749.571 uV, v_off_fin = 780.511 uV 18:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.009 uVs 18:36:13 Integrated Voltage Measurement... 18:36:22 Voltage Offset Correction: v_off_ini = 760.263 uV, v_off_fin = 747.015 uV 18:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.220 uVs 18:36:22 Integrated Voltage Measurement... 18:36:31 Voltage Offset Correction: v_off_ini = 748.500 uV, v_off_fin = 774.549 uV 18:36:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.237 uVs 18:36:31 Integrated Voltage Measurement... 18:36:40 Voltage Offset Correction: v_off_ini = 749.574 uV, v_off_fin = 744.277 uV 18:36:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.540 uVs 18:36:40 Integrated Voltage Measurement... 18:36:49 Voltage Offset Correction: v_off_ini = 745.849 uV, v_off_fin = 753.857 uV 18:36:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.418 uVs 18:36:53 I1Y Average and RMS of Measurements VT = -181.540 +- 8.077 uVs I1Y = -36.308 +- 1.615 uTm 18:36:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:37:01 Integrated Voltage Measurement... 18:37:10 Voltage Offset Correction: v_off_ini = 767.982 uV, v_off_fin = 758.962 uV 18:37:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.800 uVs 18:37:10 Integrated Voltage Measurement... 18:37:19 Voltage Offset Correction: v_off_ini = 769.184 uV, v_off_fin = 773.896 uV 18:37:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.207 uVs 18:37:19 Integrated Voltage Measurement... 18:37:28 Voltage Offset Correction: v_off_ini = 766.879 uV, v_off_fin = 749.184 uV 18:37:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.848 uVs 18:37:28 Integrated Voltage Measurement... 18:37:37 Voltage Offset Correction: v_off_ini = 756.733 uV, v_off_fin = 761.742 uV 18:37:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.058 uVs 18:37:37 Integrated Voltage Measurement... 18:37:46 Voltage Offset Correction: v_off_ini = 765.613 uV, v_off_fin = 759.688 uV 18:37:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.713 uVs 18:37:46 Integrated Voltage Measurement... 18:37:55 Voltage Offset Correction: v_off_ini = 765.428 uV, v_off_fin = 774.386 uV 18:37:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.534 uVs 18:37:57 I2X Average and RMS of Measurements VT = -37.527 +- 7.734 uVs I2X = 3.452 +- 0.712 uTm^2 18:38:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:38:05 Integrated Voltage Measurement... 18:38:14 Voltage Offset Correction: v_off_ini = 763.398 uV, v_off_fin = 758.944 uV 18:38:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -503.110 uVs 18:38:14 Integrated Voltage Measurement... 18:38:23 Voltage Offset Correction: v_off_ini = 769.312 uV, v_off_fin = 763.190 uV 18:38:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 489.009 uVs 18:38:23 Integrated Voltage Measurement... 18:38:32 Voltage Offset Correction: v_off_ini = 771.280 uV, v_off_fin = 768.398 uV 18:38:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.954 uVs 18:38:32 Integrated Voltage Measurement... 18:38:41 Voltage Offset Correction: v_off_ini = 768.228 uV, v_off_fin = 764.477 uV 18:38:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.557 uVs 18:38:41 Integrated Voltage Measurement... 18:38:50 Voltage Offset Correction: v_off_ini = 763.430 uV, v_off_fin = 754.700 uV 18:38:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -517.123 uVs 18:38:50 Integrated Voltage Measurement... 18:38:59 Voltage Offset Correction: v_off_ini = 758.344 uV, v_off_fin = 762.598 uV 18:38:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.863 uVs 18:39:02 I2Y Average and RMS of Measurements VT = -502.436 +- 7.196 uVs I2Y = -46.225 +- 0.661 uTm^2 18:39:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:39:14 Integrated Voltage Measurement... 18:39:23 Voltage Offset Correction: v_off_ini = 775.177 uV, v_off_fin = 765.310 uV 18:39:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -41.463 uVs 18:39:23 Integrated Voltage Measurement... 18:39:32 Voltage Offset Correction: v_off_ini = 756.858 uV, v_off_fin = 768.577 uV 18:39:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.065 uVs 18:39:32 Integrated Voltage Measurement... 18:39:41 Voltage Offset Correction: v_off_ini = 765.198 uV, v_off_fin = 768.063 uV 18:39:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.222 uVs 18:39:41 Integrated Voltage Measurement... 18:39:50 Voltage Offset Correction: v_off_ini = 763.742 uV, v_off_fin = 758.397 uV 18:39:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.741 uVs 18:39:50 Integrated Voltage Measurement... 18:39:59 Voltage Offset Correction: v_off_ini = 757.723 uV, v_off_fin = 756.794 uV 18:39:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.387 uVs 18:39:59 Integrated Voltage Measurement... 18:40:08 Voltage Offset Correction: v_off_ini = 770.462 uV, v_off_fin = 767.678 uV 18:40:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.965 uVs 18:40:12 I1X Average and RMS of Measurements VT = -46.974 +- 15.410 uVs I1X = 9.395 +- 3.082 uTm 18:40:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:40:19 Integrated Voltage Measurement... 18:40:28 Voltage Offset Correction: v_off_ini = 770.898 uV, v_off_fin = 756.316 uV 18:40:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.273 uVs 18:40:28 Integrated Voltage Measurement... 18:40:37 Voltage Offset Correction: v_off_ini = 777.306 uV, v_off_fin = 768.407 uV 18:40:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.323 uVs 18:40:37 Integrated Voltage Measurement... 18:40:46 Voltage Offset Correction: v_off_ini = 780.905 uV, v_off_fin = 775.504 uV 18:40:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.144 uVs 18:40:46 Integrated Voltage Measurement... 18:40:55 Voltage Offset Correction: v_off_ini = 777.626 uV, v_off_fin = 786.700 uV 18:40:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.983 uVs 18:40:55 Integrated Voltage Measurement... 18:41:04 Voltage Offset Correction: v_off_ini = 773.973 uV, v_off_fin = 760.350 uV 18:41:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.743 uVs 18:41:04 Integrated Voltage Measurement... 18:41:13 Voltage Offset Correction: v_off_ini = 764.306 uV, v_off_fin = 779.262 uV 18:41:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.770 uVs 18:41:17 I1Y Average and RMS of Measurements VT = -191.872 +- 3.286 uVs I1Y = -38.374 +- 0.657 uTm 18:41:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:41:22 Integrated Voltage Measurement... 18:41:31 Voltage Offset Correction: v_off_ini = 761.682 uV, v_off_fin = 768.126 uV 18:41:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.140 uVs 18:41:31 Integrated Voltage Measurement... 18:41:40 Voltage Offset Correction: v_off_ini = 782.705 uV, v_off_fin = 777.897 uV 18:41:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.446 uVs 18:41:40 Integrated Voltage Measurement... 18:41:49 Voltage Offset Correction: v_off_ini = 751.737 uV, v_off_fin = 754.102 uV 18:41:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.242 uVs 18:41:49 Integrated Voltage Measurement... 18:41:58 Voltage Offset Correction: v_off_ini = 752.105 uV, v_off_fin = 762.043 uV 18:41:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.551 uVs 18:41:58 Integrated Voltage Measurement... 18:42:07 Voltage Offset Correction: v_off_ini = 756.648 uV, v_off_fin = 748.066 uV 18:42:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.221 uVs 18:42:07 Integrated Voltage Measurement... 18:42:16 Voltage Offset Correction: v_off_ini = 759.576 uV, v_off_fin = 776.802 uV 18:42:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.860 uVs 18:42:19 I2X Average and RMS of Measurements VT = -16.243 +- 7.154 uVs I2X = 1.494 +- 0.658 uTm^2 18:42:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:42:24 Integrated Voltage Measurement... 18:42:33 Voltage Offset Correction: v_off_ini = 756.279 uV, v_off_fin = 761.279 uV 18:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -499.170 uVs 18:42:33 Integrated Voltage Measurement... 18:42:42 Voltage Offset Correction: v_off_ini = 761.271 uV, v_off_fin = 759.317 uV 18:42:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.725 uVs 18:42:42 Integrated Voltage Measurement... 18:42:51 Voltage Offset Correction: v_off_ini = 757.063 uV, v_off_fin = 755.570 uV 18:42:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.104 uVs 18:42:51 Integrated Voltage Measurement... 18:43:00 Voltage Offset Correction: v_off_ini = 754.886 uV, v_off_fin = 753.604 uV 18:43:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.406 uVs 18:43:00 Integrated Voltage Measurement... 18:43:09 Voltage Offset Correction: v_off_ini = 747.684 uV, v_off_fin = 737.614 uV 18:43:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.561 uVs 18:43:09 Integrated Voltage Measurement... 18:43:18 Voltage Offset Correction: v_off_ini = 754.005 uV, v_off_fin = 743.781 uV 18:43:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.981 uVs 18:43:21 I2Y Average and RMS of Measurements VT = -496.825 +- 3.503 uVs I2Y = -45.708 +- 0.322 uTm^2 18:43:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:43:29 Integrated Voltage Measurement... 18:43:38 Voltage Offset Correction: v_off_ini = 761.821 uV, v_off_fin = 747.826 uV 18:43:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.174 uVs 18:43:38 Integrated Voltage Measurement... 18:43:47 Voltage Offset Correction: v_off_ini = 759.428 uV, v_off_fin = 747.074 uV 18:43:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.565 uVs 18:43:47 Integrated Voltage Measurement... 18:43:56 Voltage Offset Correction: v_off_ini = 744.025 uV, v_off_fin = 739.577 uV 18:43:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.246 uVs 18:43:56 Integrated Voltage Measurement... 18:44:05 Voltage Offset Correction: v_off_ini = 748.174 uV, v_off_fin = 757.828 uV 18:44:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.468 uVs 18:44:05 Integrated Voltage Measurement... 18:44:14 Voltage Offset Correction: v_off_ini = 751.810 uV, v_off_fin = 755.568 uV 18:44:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.099 uVs 18:44:14 Integrated Voltage Measurement... 18:44:23 Voltage Offset Correction: v_off_ini = 746.090 uV, v_off_fin = 754.531 uV 18:44:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.131 uVs 18:44:27 I1X Average and RMS of Measurements VT = -45.447 +- 7.355 uVs I1X = 9.090 +- 1.471 uTm 18:44:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:44:34 Integrated Voltage Measurement... 18:44:43 Voltage Offset Correction: v_off_ini = 737.591 uV, v_off_fin = 741.872 uV 18:44:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.482 uVs 18:44:43 Integrated Voltage Measurement... 18:44:52 Voltage Offset Correction: v_off_ini = 745.874 uV, v_off_fin = 764.223 uV 18:44:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.209 uVs 18:44:52 Integrated Voltage Measurement... 18:45:01 Voltage Offset Correction: v_off_ini = 775.836 uV, v_off_fin = 753.057 uV 18:45:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.140 uVs 18:45:01 Integrated Voltage Measurement... 18:45:10 Voltage Offset Correction: v_off_ini = 756.911 uV, v_off_fin = 775.371 uV 18:45:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.844 uVs 18:45:10 Integrated Voltage Measurement... 18:45:19 Voltage Offset Correction: v_off_ini = 762.781 uV, v_off_fin = 763.839 uV 18:45:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.165 uVs 18:45:19 Integrated Voltage Measurement... 18:45:28 Voltage Offset Correction: v_off_ini = 767.610 uV, v_off_fin = 779.959 uV 18:45:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.452 uVs 18:45:32 I1Y Average and RMS of Measurements VT = -190.049 +- 6.314 uVs I1Y = -38.010 +- 1.263 uTm 18:45:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:45:38 Integrated Voltage Measurement... 18:45:47 Voltage Offset Correction: v_off_ini = 765.344 uV, v_off_fin = 753.674 uV 18:45:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.037 uVs 18:45:47 Integrated Voltage Measurement... 18:45:56 Voltage Offset Correction: v_off_ini = 772.713 uV, v_off_fin = 768.412 uV 18:45:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.884 uVs 18:45:56 Integrated Voltage Measurement... 18:46:05 Voltage Offset Correction: v_off_ini = 770.084 uV, v_off_fin = 758.238 uV 18:46:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.122 uVs 18:46:05 Integrated Voltage Measurement... 18:46:14 Voltage Offset Correction: v_off_ini = 772.842 uV, v_off_fin = 766.715 uV 18:46:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.340 uVs 18:46:14 Integrated Voltage Measurement... 18:46:23 Voltage Offset Correction: v_off_ini = 773.613 uV, v_off_fin = 762.400 uV 18:46:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -13.661 uVs 18:46:23 Integrated Voltage Measurement... 18:46:32 Voltage Offset Correction: v_off_ini = 768.701 uV, v_off_fin = 772.297 uV 18:46:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.951 uVs 18:46:34 I2X Average and RMS of Measurements VT = -21.832 +- 2.591 uVs I2X = 2.009 +- 0.238 uTm^2 18:46:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:46:39 Integrated Voltage Measurement... 18:46:48 Voltage Offset Correction: v_off_ini = 767.014 uV, v_off_fin = 769.519 uV 18:46:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.835 uVs 18:46:48 Integrated Voltage Measurement... 18:46:57 Voltage Offset Correction: v_off_ini = 763.921 uV, v_off_fin = 773.799 uV 18:46:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.791 uVs 18:46:57 Integrated Voltage Measurement... 18:47:06 Voltage Offset Correction: v_off_ini = 770.536 uV, v_off_fin = 764.684 uV 18:47:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.202 uVs 18:47:06 Integrated Voltage Measurement... 18:47:15 Voltage Offset Correction: v_off_ini = 767.607 uV, v_off_fin = 772.098 uV 18:47:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.862 uVs 18:47:16 Integrated Voltage Measurement... 18:47:24 Voltage Offset Correction: v_off_ini = 766.352 uV, v_off_fin = 762.712 uV 18:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.801 uVs 18:47:25 Integrated Voltage Measurement... 18:47:34 Voltage Offset Correction: v_off_ini = 771.509 uV, v_off_fin = 767.678 uV 18:47:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 521.423 uVs 18:47:36 I2Y Average and RMS of Measurements VT = -501.653 +- 10.781 uVs I2Y = -46.152 +- 0.992 uTm^2 18:47:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:47:44 Integrated Voltage Measurement... 18:47:53 Voltage Offset Correction: v_off_ini = 777.361 uV, v_off_fin = 762.425 uV 18:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.671 uVs 18:47:53 Integrated Voltage Measurement... 18:48:02 Voltage Offset Correction: v_off_ini = 773.711 uV, v_off_fin = 772.861 uV 18:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.877 uVs 18:48:02 Integrated Voltage Measurement... 18:48:11 Voltage Offset Correction: v_off_ini = 763.427 uV, v_off_fin = 766.141 uV 18:48:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -65.518 uVs 18:48:11 Integrated Voltage Measurement... 18:48:20 Voltage Offset Correction: v_off_ini = 776.901 uV, v_off_fin = 783.876 uV 18:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 36.614 uVs 18:48:20 Integrated Voltage Measurement... 18:48:29 Voltage Offset Correction: v_off_ini = 767.296 uV, v_off_fin = 766.600 uV 18:48:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -38.704 uVs 18:48:29 Integrated Voltage Measurement... 18:48:38 Voltage Offset Correction: v_off_ini = 762.814 uV, v_off_fin = 758.979 uV 18:48:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 47.151 uVs 18:48:43 I1X Average and RMS of Measurements VT = -51.589 +- 7.295 uVs I1X = 10.319 +- 1.459 uTm 18:48:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:48:49 Integrated Voltage Measurement... 18:48:58 Voltage Offset Correction: v_off_ini = 756.249 uV, v_off_fin = 752.575 uV 18:48:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -173.183 uVs 18:48:58 Integrated Voltage Measurement... 18:49:07 Voltage Offset Correction: v_off_ini = 764.034 uV, v_off_fin = 780.976 uV 18:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.066 uVs 18:49:07 Integrated Voltage Measurement... 18:49:16 Voltage Offset Correction: v_off_ini = 776.887 uV, v_off_fin = 763.041 uV 18:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.154 uVs 18:49:16 Integrated Voltage Measurement... 18:49:25 Voltage Offset Correction: v_off_ini = 754.482 uV, v_off_fin = 761.724 uV 18:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.100 uVs 18:49:25 Integrated Voltage Measurement... 18:49:34 Voltage Offset Correction: v_off_ini = 754.311 uV, v_off_fin = 758.801 uV 18:49:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.167 uVs 18:49:34 Integrated Voltage Measurement... 18:49:43 Voltage Offset Correction: v_off_ini = 760.413 uV, v_off_fin = 777.777 uV 18:49:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.413 uVs 18:49:48 I1Y Average and RMS of Measurements VT = -188.847 +- 2.548 uVs I1Y = -37.771 +- 0.510 uTm 18:49:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:49:53 Integrated Voltage Measurement... 18:50:02 Voltage Offset Correction: v_off_ini = 770.968 uV, v_off_fin = 775.927 uV 18:50:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.399 uVs 18:50:02 Integrated Voltage Measurement... 18:50:11 Voltage Offset Correction: v_off_ini = 783.304 uV, v_off_fin = 783.388 uV 18:50:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.409 uVs 18:50:11 Integrated Voltage Measurement... 18:50:20 Voltage Offset Correction: v_off_ini = 759.958 uV, v_off_fin = 771.603 uV 18:50:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.800 uVs 18:50:20 Integrated Voltage Measurement... 18:50:29 Voltage Offset Correction: v_off_ini = 762.254 uV, v_off_fin = 782.203 uV 18:50:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.271 uVs 18:50:29 Integrated Voltage Measurement... 18:50:38 Voltage Offset Correction: v_off_ini = 776.711 uV, v_off_fin = 767.824 uV 18:50:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.408 uVs 18:50:38 Integrated Voltage Measurement... 18:50:47 Voltage Offset Correction: v_off_ini = 774.183 uV, v_off_fin = 775.412 uV 18:50:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.199 uVs 18:50:49 I2X Average and RMS of Measurements VT = -29.081 +- 8.602 uVs I2X = 2.675 +- 0.791 uTm^2 18:50:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:50:55 Integrated Voltage Measurement... 18:51:04 Voltage Offset Correction: v_off_ini = 760.388 uV, v_off_fin = 765.918 uV 18:51:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.889 uVs 18:51:04 Integrated Voltage Measurement... 18:51:13 Voltage Offset Correction: v_off_ini = 776.121 uV, v_off_fin = 771.300 uV 18:51:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 502.043 uVs 18:51:13 Integrated Voltage Measurement... 18:51:22 Voltage Offset Correction: v_off_ini = 753.407 uV, v_off_fin = 773.505 uV 18:51:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -471.726 uVs 18:51:22 Integrated Voltage Measurement... 18:51:31 Voltage Offset Correction: v_off_ini = 766.190 uV, v_off_fin = 774.686 uV 18:51:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 489.924 uVs 18:51:31 Integrated Voltage Measurement... 18:51:40 Voltage Offset Correction: v_off_ini = 761.465 uV, v_off_fin = 766.932 uV 18:51:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.612 uVs 18:51:40 Integrated Voltage Measurement... 18:51:49 Voltage Offset Correction: v_off_ini = 760.293 uV, v_off_fin = 764.142 uV 18:51:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.125 uVs 18:51:51 I2Y Average and RMS of Measurements VT = -492.053 +- 7.966 uVs I2Y = -45.270 +- 0.732 uTm^2 18:51:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:52:00 Integrated Voltage Measurement... 18:52:09 Voltage Offset Correction: v_off_ini = 764.987 uV, v_off_fin = 755.774 uV 18:52:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -65.703 uVs 18:52:09 Integrated Voltage Measurement... 18:52:18 Voltage Offset Correction: v_off_ini = 767.109 uV, v_off_fin = 764.418 uV 18:52:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.589 uVs 18:52:18 Integrated Voltage Measurement... 18:52:27 Voltage Offset Correction: v_off_ini = 767.152 uV, v_off_fin = 768.173 uV 18:52:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.371 uVs 18:52:27 Integrated Voltage Measurement... 18:52:36 Voltage Offset Correction: v_off_ini = 764.297 uV, v_off_fin = 764.865 uV 18:52:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.907 uVs 18:52:36 Integrated Voltage Measurement... 18:52:45 Voltage Offset Correction: v_off_ini = 764.445 uV, v_off_fin = 767.108 uV 18:52:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.330 uVs 18:52:45 Integrated Voltage Measurement... 18:52:54 Voltage Offset Correction: v_off_ini = 767.516 uV, v_off_fin = 766.373 uV 18:52:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 52.764 uVs 18:52:58 I1X Average and RMS of Measurements VT = -54.944 +- 3.511 uVs I1X = 10.990 +- 0.702 uTm 18:53:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:53:05 Integrated Voltage Measurement... 18:53:14 Voltage Offset Correction: v_off_ini = 765.487 uV, v_off_fin = 758.691 uV 18:53:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -167.936 uVs 18:53:14 Integrated Voltage Measurement... 18:53:23 Voltage Offset Correction: v_off_ini = 770.012 uV, v_off_fin = 775.392 uV 18:53:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.634 uVs 18:53:23 Integrated Voltage Measurement... 18:53:32 Voltage Offset Correction: v_off_ini = 754.977 uV, v_off_fin = 747.371 uV 18:53:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.740 uVs 18:53:32 Integrated Voltage Measurement... 18:53:41 Voltage Offset Correction: v_off_ini = 772.976 uV, v_off_fin = 773.981 uV 18:53:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.769 uVs 18:53:41 Integrated Voltage Measurement... 18:53:50 Voltage Offset Correction: v_off_ini = 759.794 uV, v_off_fin = 746.562 uV 18:53:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.609 uVs 18:53:50 Integrated Voltage Measurement... 18:53:59 Voltage Offset Correction: v_off_ini = 770.457 uV, v_off_fin = 768.877 uV 18:53:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.546 uVs 18:54:03 I1Y Average and RMS of Measurements VT = -177.039 +- 5.913 uVs I1Y = -35.408 +- 1.183 uTm 18:54:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:54:08 Integrated Voltage Measurement... 18:54:17 Voltage Offset Correction: v_off_ini = 756.106 uV, v_off_fin = 750.906 uV 18:54:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.939 uVs 18:54:17 Integrated Voltage Measurement... 18:54:26 Voltage Offset Correction: v_off_ini = 764.971 uV, v_off_fin = 766.210 uV 18:54:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.715 uVs 18:54:26 Integrated Voltage Measurement... 18:54:35 Voltage Offset Correction: v_off_ini = 754.378 uV, v_off_fin = 754.183 uV 18:54:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.590 uVs 18:54:35 Integrated Voltage Measurement... 18:54:44 Voltage Offset Correction: v_off_ini = 758.850 uV, v_off_fin = 762.278 uV 18:54:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.400 uVs 18:54:44 Integrated Voltage Measurement... 18:54:53 Voltage Offset Correction: v_off_ini = 752.715 uV, v_off_fin = 739.967 uV 18:54:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -11.891 uVs 18:54:53 Integrated Voltage Measurement... 18:55:02 Voltage Offset Correction: v_off_ini = 761.750 uV, v_off_fin = 778.379 uV 18:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.284 uVs 18:55:05 I2X Average and RMS of Measurements VT = -20.970 +- 2.171 uVs I2X = 1.929 +- 0.200 uTm^2 18:55:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:55:10 Integrated Voltage Measurement... 18:55:19 Voltage Offset Correction: v_off_ini = 756.766 uV, v_off_fin = 752.749 uV 18:55:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.910 uVs 18:55:19 Integrated Voltage Measurement... 18:55:28 Voltage Offset Correction: v_off_ini = 745.330 uV, v_off_fin = 755.481 uV 18:55:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.834 uVs 18:55:28 Integrated Voltage Measurement... 18:55:37 Voltage Offset Correction: v_off_ini = 751.499 uV, v_off_fin = 751.474 uV 18:55:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.179 uVs 18:55:37 Integrated Voltage Measurement... 18:55:46 Voltage Offset Correction: v_off_ini = 745.018 uV, v_off_fin = 746.229 uV 18:55:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.024 uVs 18:55:46 Integrated Voltage Measurement... 18:55:55 Voltage Offset Correction: v_off_ini = 739.444 uV, v_off_fin = 746.467 uV 18:55:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.909 uVs 18:55:55 Integrated Voltage Measurement... 18:56:04 Voltage Offset Correction: v_off_ini = 739.282 uV, v_off_fin = 744.405 uV 18:56:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.944 uVs 18:56:06 I2Y Average and RMS of Measurements VT = -503.133 +- 2.369 uVs I2Y = -46.288 +- 0.218 uTm^2 18:56:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:56:15 Integrated Voltage Measurement... 18:56:24 Voltage Offset Correction: v_off_ini = 760.601 uV, v_off_fin = 749.290 uV 18:56:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.759 uVs 18:56:24 Integrated Voltage Measurement... 18:56:33 Voltage Offset Correction: v_off_ini = 764.515 uV, v_off_fin = 763.909 uV 18:56:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.486 uVs 18:56:33 Integrated Voltage Measurement... 18:56:42 Voltage Offset Correction: v_off_ini = 754.327 uV, v_off_fin = 747.689 uV 18:56:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.712 uVs 18:56:42 Integrated Voltage Measurement... 18:56:51 Voltage Offset Correction: v_off_ini = 757.184 uV, v_off_fin = 759.524 uV 18:56:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.468 uVs 18:56:51 Integrated Voltage Measurement... 18:57:00 Voltage Offset Correction: v_off_ini = 747.603 uV, v_off_fin = 749.729 uV 18:57:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.232 uVs 18:57:00 Integrated Voltage Measurement... 18:57:09 Voltage Offset Correction: v_off_ini = 759.897 uV, v_off_fin = 768.963 uV 18:57:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.955 uVs 18:57:13 I1X Average and RMS of Measurements VT = -37.935 +- 7.692 uVs I1X = 7.587 +- 1.539 uTm 18:57:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:57:20 Integrated Voltage Measurement... 18:57:29 Voltage Offset Correction: v_off_ini = 754.744 uV, v_off_fin = 762.498 uV 18:57:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.435 uVs 18:57:29 Integrated Voltage Measurement... 18:57:38 Voltage Offset Correction: v_off_ini = 763.461 uV, v_off_fin = 787.689 uV 18:57:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.294 uVs 18:57:38 Integrated Voltage Measurement... 18:57:47 Voltage Offset Correction: v_off_ini = 763.606 uV, v_off_fin = 760.743 uV 18:57:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.326 uVs 18:57:47 Integrated Voltage Measurement... 18:57:56 Voltage Offset Correction: v_off_ini = 769.346 uV, v_off_fin = 769.310 uV 18:57:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.008 uVs 18:57:56 Integrated Voltage Measurement... 18:58:05 Voltage Offset Correction: v_off_ini = 755.079 uV, v_off_fin = 749.566 uV 18:58:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.674 uVs 18:58:05 Integrated Voltage Measurement... 18:58:14 Voltage Offset Correction: v_off_ini = 758.823 uV, v_off_fin = 775.702 uV 18:58:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.460 uVs 18:58:18 I1Y Average and RMS of Measurements VT = -180.866 +- 2.989 uVs I1Y = -36.171 +- 0.597 uTm 18:58:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:58:23 Integrated Voltage Measurement... 18:58:32 Voltage Offset Correction: v_off_ini = 745.674 uV, v_off_fin = 750.918 uV 18:58:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -7.344 uVs 18:58:32 Integrated Voltage Measurement... 18:58:41 Voltage Offset Correction: v_off_ini = 755.566 uV, v_off_fin = 754.947 uV 18:58:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.063 uVs 18:58:41 Integrated Voltage Measurement... 18:58:50 Voltage Offset Correction: v_off_ini = 757.849 uV, v_off_fin = 749.367 uV 18:58:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.765 uVs 18:58:50 Integrated Voltage Measurement... 18:58:59 Voltage Offset Correction: v_off_ini = 746.514 uV, v_off_fin = 761.331 uV 18:58:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.701 uVs 18:59:00 Integrated Voltage Measurement... 18:59:08 Voltage Offset Correction: v_off_ini = 753.668 uV, v_off_fin = 748.428 uV 18:59:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.818 uVs 18:59:09 Integrated Voltage Measurement... 18:59:18 Voltage Offset Correction: v_off_ini = 767.372 uV, v_off_fin = 765.370 uV 18:59:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.940 uVs 18:59:20 I2X Average and RMS of Measurements VT = -24.605 +- 9.989 uVs I2X = 2.264 +- 0.919 uTm^2 18:59:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:59:25 Integrated Voltage Measurement... 18:59:34 Voltage Offset Correction: v_off_ini = 769.184 uV, v_off_fin = 757.891 uV 18:59:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.546 uVs 18:59:34 Integrated Voltage Measurement... 18:59:43 Voltage Offset Correction: v_off_ini = 763.064 uV, v_off_fin = 748.171 uV 18:59:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.324 uVs 18:59:43 Integrated Voltage Measurement... 18:59:52 Voltage Offset Correction: v_off_ini = 748.033 uV, v_off_fin = 758.016 uV 18:59:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -484.175 uVs 18:59:52 Integrated Voltage Measurement... 19:00:01 Voltage Offset Correction: v_off_ini = 766.592 uV, v_off_fin = 764.717 uV 19:00:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.112 uVs 19:00:01 Integrated Voltage Measurement... 19:00:10 Voltage Offset Correction: v_off_ini = 758.967 uV, v_off_fin = 752.217 uV 19:00:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.400 uVs 19:00:10 Integrated Voltage Measurement... 19:00:19 Voltage Offset Correction: v_off_ini = 752.825 uV, v_off_fin = 754.539 uV 19:00:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.627 uVs 19:00:22 I2Y Average and RMS of Measurements VT = -498.697 +- 8.538 uVs I2Y = -45.880 +- 0.786 uTm^2 19:00:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:00:43 Integrated Voltage Measurement... 19:00:52 Voltage Offset Correction: v_off_ini = 761.610 uV, v_off_fin = 744.168 uV 19:00:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.627 uVs 19:00:52 Integrated Voltage Measurement... 19:01:01 Voltage Offset Correction: v_off_ini = 754.767 uV, v_off_fin = 752.337 uV 19:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.953 uVs 19:01:01 Integrated Voltage Measurement... 19:01:10 Voltage Offset Correction: v_off_ini = 756.576 uV, v_off_fin = 740.125 uV 19:01:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.388 uVs 19:01:10 Integrated Voltage Measurement... 19:01:19 Voltage Offset Correction: v_off_ini = 751.496 uV, v_off_fin = 751.433 uV 19:01:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.153 uVs 19:01:19 Integrated Voltage Measurement... 19:01:28 Voltage Offset Correction: v_off_ini = 742.370 uV, v_off_fin = 727.986 uV 19:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.276 uVs 19:01:28 Integrated Voltage Measurement... 19:01:37 Voltage Offset Correction: v_off_ini = 737.791 uV, v_off_fin = 752.293 uV 19:01:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.013 uVs 19:01:41 I1X Average and RMS of Measurements VT = -69.902 +- 1.245 uVs I1X = 13.981 +- 0.250 uTm 19:01:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:01:48 Integrated Voltage Measurement... 19:01:57 Voltage Offset Correction: v_off_ini = 737.864 uV, v_off_fin = 730.753 uV 19:01:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.919 uVs 19:01:57 Integrated Voltage Measurement... 19:02:06 Voltage Offset Correction: v_off_ini = 729.775 uV, v_off_fin = 735.292 uV 19:02:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.054 uVs 19:02:06 Integrated Voltage Measurement... 19:02:15 Voltage Offset Correction: v_off_ini = 725.655 uV, v_off_fin = 726.896 uV 19:02:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.954 uVs 19:02:15 Integrated Voltage Measurement... 19:02:24 Voltage Offset Correction: v_off_ini = 740.657 uV, v_off_fin = 743.337 uV 19:02:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.051 uVs 19:02:24 Integrated Voltage Measurement... 19:02:33 Voltage Offset Correction: v_off_ini = 730.609 uV, v_off_fin = 728.787 uV 19:02:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.500 uVs 19:02:33 Integrated Voltage Measurement... 19:02:42 Voltage Offset Correction: v_off_ini = 739.146 uV, v_off_fin = 745.814 uV 19:02:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.682 uVs 19:02:46 I1Y Average and RMS of Measurements VT = -191.360 +- 9.017 uVs I1Y = -38.272 +- 1.803 uTm 19:02:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:02:54 Integrated Voltage Measurement... 19:03:03 Voltage Offset Correction: v_off_ini = 713.715 uV, v_off_fin = 715.472 uV 19:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.830 uVs 19:03:03 Integrated Voltage Measurement... 19:03:12 Voltage Offset Correction: v_off_ini = 728.301 uV, v_off_fin = 742.717 uV 19:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.551 uVs 19:03:12 Integrated Voltage Measurement... 19:03:21 Voltage Offset Correction: v_off_ini = 734.344 uV, v_off_fin = 731.268 uV 19:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.946 uVs 19:03:21 Integrated Voltage Measurement... 19:03:30 Voltage Offset Correction: v_off_ini = 741.093 uV, v_off_fin = 748.419 uV 19:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.378 uVs 19:03:30 Integrated Voltage Measurement... 19:03:39 Voltage Offset Correction: v_off_ini = 743.036 uV, v_off_fin = 735.395 uV 19:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.003 uVs 19:03:39 Integrated Voltage Measurement... 19:03:48 Voltage Offset Correction: v_off_ini = 745.742 uV, v_off_fin = 754.580 uV 19:03:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.245 uVs 19:03:51 I2X Average and RMS of Measurements VT = -46.992 +- 2.069 uVs I2X = 4.323 +- 0.190 uTm^2 19:03:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:03:59 Integrated Voltage Measurement... 19:04:08 Voltage Offset Correction: v_off_ini = 748.278 uV, v_off_fin = 741.526 uV 19:04:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -492.926 uVs 19:04:08 Integrated Voltage Measurement... 19:04:17 Voltage Offset Correction: v_off_ini = 734.314 uV, v_off_fin = 739.877 uV 19:04:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.464 uVs 19:04:17 Integrated Voltage Measurement... 19:04:26 Voltage Offset Correction: v_off_ini = 733.742 uV, v_off_fin = 733.916 uV 19:04:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.464 uVs 19:04:26 Integrated Voltage Measurement... 19:04:35 Voltage Offset Correction: v_off_ini = 728.672 uV, v_off_fin = 733.561 uV 19:04:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.828 uVs 19:04:35 Integrated Voltage Measurement... 19:04:44 Voltage Offset Correction: v_off_ini = 724.814 uV, v_off_fin = 734.816 uV 19:04:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -480.680 uVs 19:04:44 Integrated Voltage Measurement... 19:04:53 Voltage Offset Correction: v_off_ini = 737.002 uV, v_off_fin = 746.964 uV 19:04:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.330 uVs 19:04:55 I2Y Average and RMS of Measurements VT = -491.449 +- 9.285 uVs I2Y = -45.214 +- 0.854 uTm^2 19:05:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:05:04 Integrated Voltage Measurement... 19:05:13 Voltage Offset Correction: v_off_ini = 732.998 uV, v_off_fin = 741.581 uV 19:05:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -88.796 uVs 19:05:13 Integrated Voltage Measurement... 19:05:22 Voltage Offset Correction: v_off_ini = 743.263 uV, v_off_fin = 734.989 uV 19:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.122 uVs 19:05:22 Integrated Voltage Measurement... 19:05:31 Voltage Offset Correction: v_off_ini = 730.551 uV, v_off_fin = 734.693 uV 19:05:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.443 uVs 19:05:31 Integrated Voltage Measurement... 19:05:40 Voltage Offset Correction: v_off_ini = 738.910 uV, v_off_fin = 750.399 uV 19:05:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.594 uVs 19:05:40 Integrated Voltage Measurement... 19:05:49 Voltage Offset Correction: v_off_ini = 730.500 uV, v_off_fin = 740.471 uV 19:05:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.923 uVs 19:05:49 Integrated Voltage Measurement... 19:05:58 Voltage Offset Correction: v_off_ini = 731.064 uV, v_off_fin = 743.437 uV 19:05:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.104 uVs 19:06:02 I1X Average and RMS of Measurements VT = -64.997 +- 5.330 uVs I1X = 13.000 +- 1.067 uTm 19:06:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:06:09 Integrated Voltage Measurement... 19:06:18 Voltage Offset Correction: v_off_ini = 747.227 uV, v_off_fin = 732.919 uV 19:06:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.205 uVs 19:06:18 Integrated Voltage Measurement... 19:06:27 Voltage Offset Correction: v_off_ini = 734.874 uV, v_off_fin = 747.235 uV 19:06:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.057 uVs 19:06:27 Integrated Voltage Measurement... 19:06:36 Voltage Offset Correction: v_off_ini = 721.973 uV, v_off_fin = 716.076 uV 19:06:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.339 uVs 19:06:36 Integrated Voltage Measurement... 19:06:45 Voltage Offset Correction: v_off_ini = 722.593 uV, v_off_fin = 742.139 uV 19:06:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.137 uVs 19:06:45 Integrated Voltage Measurement... 19:06:54 Voltage Offset Correction: v_off_ini = 745.621 uV, v_off_fin = 730.775 uV 19:06:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.733 uVs 19:06:54 Integrated Voltage Measurement... 19:07:03 Voltage Offset Correction: v_off_ini = 731.162 uV, v_off_fin = 755.173 uV 19:07:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.080 uVs 19:07:08 I1Y Average and RMS of Measurements VT = -195.925 +- 4.451 uVs I1Y = -39.185 +- 0.890 uTm 19:07:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:07:15 Integrated Voltage Measurement... 19:07:24 Voltage Offset Correction: v_off_ini = 708.918 uV, v_off_fin = 725.293 uV 19:07:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.417 uVs 19:07:24 Integrated Voltage Measurement... 19:07:33 Voltage Offset Correction: v_off_ini = 729.553 uV, v_off_fin = 737.091 uV 19:07:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.135 uVs 19:07:33 Integrated Voltage Measurement... 19:07:42 Voltage Offset Correction: v_off_ini = 730.846 uV, v_off_fin = 714.350 uV 19:07:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.455 uVs 19:07:42 Integrated Voltage Measurement... 19:07:51 Voltage Offset Correction: v_off_ini = 739.676 uV, v_off_fin = 741.996 uV 19:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.837 uVs 19:07:51 Integrated Voltage Measurement... 19:08:00 Voltage Offset Correction: v_off_ini = 725.281 uV, v_off_fin = 721.290 uV 19:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.006 uVs 19:08:00 Integrated Voltage Measurement... 19:08:09 Voltage Offset Correction: v_off_ini = 728.546 uV, v_off_fin = 723.033 uV 19:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.513 uVs 19:08:12 I2X Average and RMS of Measurements VT = -49.227 +- 5.045 uVs I2X = 4.529 +- 0.464 uTm^2 19:08:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:08:20 Integrated Voltage Measurement... 19:08:29 Voltage Offset Correction: v_off_ini = 727.290 uV, v_off_fin = 725.614 uV 19:08:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.724 uVs 19:08:29 Integrated Voltage Measurement... 19:08:38 Voltage Offset Correction: v_off_ini = 723.580 uV, v_off_fin = 748.300 uV 19:08:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 485.299 uVs 19:08:38 Integrated Voltage Measurement... 19:08:47 Voltage Offset Correction: v_off_ini = 737.990 uV, v_off_fin = 734.532 uV 19:08:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.756 uVs 19:08:47 Integrated Voltage Measurement... 19:08:56 Voltage Offset Correction: v_off_ini = 725.591 uV, v_off_fin = 737.602 uV 19:08:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.297 uVs 19:08:56 Integrated Voltage Measurement... 19:09:05 Voltage Offset Correction: v_off_ini = 735.424 uV, v_off_fin = 731.655 uV 19:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.150 uVs 19:09:05 Integrated Voltage Measurement... 19:09:14 Voltage Offset Correction: v_off_ini = 723.609 uV, v_off_fin = 724.598 uV 19:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.018 uVs 19:09:16 I2Y Average and RMS of Measurements VT = -500.041 +- 7.905 uVs I2Y = -46.004 +- 0.727 uTm^2 19:09:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:09:25 Integrated Voltage Measurement... 19:09:34 Voltage Offset Correction: v_off_ini = 733.704 uV, v_off_fin = 725.587 uV 19:09:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.997 uVs 19:09:34 Integrated Voltage Measurement... 19:09:43 Voltage Offset Correction: v_off_ini = 739.685 uV, v_off_fin = 739.866 uV 19:09:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.146 uVs 19:09:43 Integrated Voltage Measurement... 19:09:52 Voltage Offset Correction: v_off_ini = 733.760 uV, v_off_fin = 725.844 uV 19:09:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.405 uVs 19:09:52 Integrated Voltage Measurement... 19:10:01 Voltage Offset Correction: v_off_ini = 732.077 uV, v_off_fin = 734.583 uV 19:10:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.513 uVs 19:10:01 Integrated Voltage Measurement... 19:10:10 Voltage Offset Correction: v_off_ini = 727.868 uV, v_off_fin = 731.448 uV 19:10:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.881 uVs 19:10:10 Integrated Voltage Measurement... 19:10:19 Voltage Offset Correction: v_off_ini = 721.590 uV, v_off_fin = 736.295 uV 19:10:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.125 uVs 19:10:24 I1X Average and RMS of Measurements VT = -74.178 +- 5.184 uVs I1X = 14.836 +- 1.037 uTm 19:10:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:10:30 Integrated Voltage Measurement... 19:10:39 Voltage Offset Correction: v_off_ini = 724.304 uV, v_off_fin = 712.481 uV 19:10:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -192.279 uVs 19:10:39 Integrated Voltage Measurement... 19:10:48 Voltage Offset Correction: v_off_ini = 722.818 uV, v_off_fin = 730.317 uV 19:10:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.625 uVs 19:10:48 Integrated Voltage Measurement... 19:10:57 Voltage Offset Correction: v_off_ini = 727.593 uV, v_off_fin = 719.055 uV 19:10:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.669 uVs 19:10:57 Integrated Voltage Measurement... 19:11:06 Voltage Offset Correction: v_off_ini = 726.380 uV, v_off_fin = 732.212 uV 19:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.351 uVs 19:11:06 Integrated Voltage Measurement... 19:11:15 Voltage Offset Correction: v_off_ini = 724.814 uV, v_off_fin = 715.793 uV 19:11:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.204 uVs 19:11:15 Integrated Voltage Measurement... 19:11:24 Voltage Offset Correction: v_off_ini = 734.064 uV, v_off_fin = 739.609 uV 19:11:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.118 uVs 19:11:29 I1Y Average and RMS of Measurements VT = -191.708 +- 6.909 uVs I1Y = -38.343 +- 1.382 uTm 19:11:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:11:36 Integrated Voltage Measurement... 19:11:45 Voltage Offset Correction: v_off_ini = 714.334 uV, v_off_fin = 722.102 uV 19:11:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.429 uVs 19:11:45 Integrated Voltage Measurement... 19:11:54 Voltage Offset Correction: v_off_ini = 743.629 uV, v_off_fin = 729.587 uV 19:11:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.981 uVs 19:11:54 Integrated Voltage Measurement... 19:12:03 Voltage Offset Correction: v_off_ini = 743.525 uV, v_off_fin = 731.630 uV 19:12:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.810 uVs 19:12:03 Integrated Voltage Measurement... 19:12:12 Voltage Offset Correction: v_off_ini = 740.615 uV, v_off_fin = 745.347 uV 19:12:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.128 uVs 19:12:12 Integrated Voltage Measurement... 19:12:21 Voltage Offset Correction: v_off_ini = 731.968 uV, v_off_fin = 720.847 uV 19:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.994 uVs 19:12:22 Integrated Voltage Measurement... 19:12:31 Voltage Offset Correction: v_off_ini = 731.927 uV, v_off_fin = 741.320 uV 19:12:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.264 uVs 19:12:33 I2X Average and RMS of Measurements VT = -51.768 +- 1.226 uVs I2X = 4.763 +- 0.113 uTm^2 19:12:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:12:41 Integrated Voltage Measurement... 19:12:50 Voltage Offset Correction: v_off_ini = 732.357 uV, v_off_fin = 739.154 uV 19:12:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.189 uVs 19:12:50 Integrated Voltage Measurement... 19:12:59 Voltage Offset Correction: v_off_ini = 730.280 uV, v_off_fin = 739.657 uV 19:12:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.612 uVs 19:12:59 Integrated Voltage Measurement... 19:13:08 Voltage Offset Correction: v_off_ini = 731.749 uV, v_off_fin = 746.233 uV 19:13:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -488.868 uVs 19:13:08 Integrated Voltage Measurement... 19:13:17 Voltage Offset Correction: v_off_ini = 741.766 uV, v_off_fin = 735.243 uV 19:13:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 485.860 uVs 19:13:17 Integrated Voltage Measurement... 19:13:26 Voltage Offset Correction: v_off_ini = 734.121 uV, v_off_fin = 747.881 uV 19:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.806 uVs 19:13:26 Integrated Voltage Measurement... 19:13:35 Voltage Offset Correction: v_off_ini = 751.856 uV, v_off_fin = 753.414 uV 19:13:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.364 uVs 19:13:37 I2Y Average and RMS of Measurements VT = -489.783 +- 1.929 uVs I2Y = -45.061 +- 0.177 uTm^2 19:13:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:13:46 Integrated Voltage Measurement... 19:13:55 Voltage Offset Correction: v_off_ini = 752.644 uV, v_off_fin = 738.721 uV 19:13:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.189 uVs 19:13:55 Integrated Voltage Measurement... 19:14:04 Voltage Offset Correction: v_off_ini = 729.961 uV, v_off_fin = 734.843 uV 19:14:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.231 uVs 19:14:04 Integrated Voltage Measurement... 19:14:13 Voltage Offset Correction: v_off_ini = 739.424 uV, v_off_fin = 739.944 uV 19:14:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.591 uVs 19:14:13 Integrated Voltage Measurement... 19:14:22 Voltage Offset Correction: v_off_ini = 725.511 uV, v_off_fin = 745.588 uV 19:14:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.258 uVs 19:14:22 Integrated Voltage Measurement... 19:14:31 Voltage Offset Correction: v_off_ini = 740.438 uV, v_off_fin = 737.923 uV 19:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.402 uVs 19:14:31 Integrated Voltage Measurement... 19:14:40 Voltage Offset Correction: v_off_ini = 734.389 uV, v_off_fin = 738.525 uV 19:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.024 uVs 19:14:45 I1X Average and RMS of Measurements VT = -82.782 +- 5.232 uVs I1X = 16.557 +- 1.047 uTm 19:14:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:14:51 Integrated Voltage Measurement... 19:15:00 Voltage Offset Correction: v_off_ini = 731.632 uV, v_off_fin = 721.416 uV 19:15:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -195.732 uVs 19:15:00 Integrated Voltage Measurement... 19:15:09 Voltage Offset Correction: v_off_ini = 729.975 uV, v_off_fin = 746.715 uV 19:15:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.988 uVs 19:15:09 Integrated Voltage Measurement... 19:15:18 Voltage Offset Correction: v_off_ini = 731.150 uV, v_off_fin = 729.878 uV 19:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.456 uVs 19:15:18 Integrated Voltage Measurement... 19:15:27 Voltage Offset Correction: v_off_ini = 738.473 uV, v_off_fin = 744.827 uV 19:15:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.425 uVs 19:15:27 Integrated Voltage Measurement... 19:15:36 Voltage Offset Correction: v_off_ini = 730.841 uV, v_off_fin = 717.254 uV 19:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.800 uVs 19:15:36 Integrated Voltage Measurement... 19:15:45 Voltage Offset Correction: v_off_ini = 730.941 uV, v_off_fin = 736.339 uV 19:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.535 uVs 19:15:50 I1Y Average and RMS of Measurements VT = -193.989 +- 1.158 uVs I1Y = -38.798 +- 0.231 uTm 19:15:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:15:57 Integrated Voltage Measurement... 19:16:06 Voltage Offset Correction: v_off_ini = 730.281 uV, v_off_fin = 728.024 uV 19:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = -40.527 uVs 19:16:06 Integrated Voltage Measurement... 19:16:15 Voltage Offset Correction: v_off_ini = 733.050 uV, v_off_fin = 750.049 uV 19:16:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.333 uVs 19:16:15 Integrated Voltage Measurement... 19:16:24 Voltage Offset Correction: v_off_ini = 736.960 uV, v_off_fin = 731.522 uV 19:16:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.344 uVs 19:16:25 Integrated Voltage Measurement... 19:16:33 Voltage Offset Correction: v_off_ini = 737.336 uV, v_off_fin = 742.743 uV 19:16:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.719 uVs 19:16:34 Integrated Voltage Measurement... 19:16:43 Voltage Offset Correction: v_off_ini = 734.748 uV, v_off_fin = 720.488 uV 19:16:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.013 uVs 19:16:43 Integrated Voltage Measurement... 19:16:52 Voltage Offset Correction: v_off_ini = 729.096 uV, v_off_fin = 740.796 uV 19:16:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.894 uVs 19:16:54 I2X Average and RMS of Measurements VT = -57.305 +- 5.148 uVs I2X = 5.272 +- 0.474 uTm^2 19:16:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:17:02 Integrated Voltage Measurement... 19:17:11 Voltage Offset Correction: v_off_ini = 740.806 uV, v_off_fin = 737.066 uV 19:17:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.793 uVs 19:17:11 Integrated Voltage Measurement... 19:17:20 Voltage Offset Correction: v_off_ini = 736.868 uV, v_off_fin = 729.697 uV 19:17:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.839 uVs 19:17:20 Integrated Voltage Measurement... 19:17:29 Voltage Offset Correction: v_off_ini = 737.318 uV, v_off_fin = 739.505 uV 19:17:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.146 uVs 19:17:29 Integrated Voltage Measurement... 19:17:38 Voltage Offset Correction: v_off_ini = 735.448 uV, v_off_fin = 738.435 uV 19:17:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.615 uVs 19:17:38 Integrated Voltage Measurement... 19:17:47 Voltage Offset Correction: v_off_ini = 726.545 uV, v_off_fin = 733.929 uV 19:17:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -511.380 uVs 19:17:47 Integrated Voltage Measurement... 19:17:56 Voltage Offset Correction: v_off_ini = 733.312 uV, v_off_fin = 733.403 uV 19:17:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.318 uVs 19:17:58 I2Y Average and RMS of Measurements VT = -492.349 +- 5.500 uVs I2Y = -45.296 +- 0.506 uTm^2 19:18:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:18:07 Integrated Voltage Measurement... 19:18:16 Voltage Offset Correction: v_off_ini = 734.623 uV, v_off_fin = 732.398 uV 19:18:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -79.422 uVs 19:18:16 Integrated Voltage Measurement... 19:18:25 Voltage Offset Correction: v_off_ini = 714.910 uV, v_off_fin = 720.681 uV 19:18:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.681 uVs 19:18:25 Integrated Voltage Measurement... 19:18:34 Voltage Offset Correction: v_off_ini = 722.085 uV, v_off_fin = 712.532 uV 19:18:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.168 uVs 19:18:34 Integrated Voltage Measurement... 19:18:43 Voltage Offset Correction: v_off_ini = 709.757 uV, v_off_fin = 725.136 uV 19:18:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.318 uVs 19:18:43 Integrated Voltage Measurement... 19:18:52 Voltage Offset Correction: v_off_ini = 725.246 uV, v_off_fin = 724.363 uV 19:18:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.155 uVs 19:18:52 Integrated Voltage Measurement... 19:19:01 Voltage Offset Correction: v_off_ini = 726.971 uV, v_off_fin = 729.693 uV 19:19:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.981 uVs 19:19:06 I1X Average and RMS of Measurements VT = -73.621 +- 2.213 uVs I1X = 14.725 +- 0.443 uTm 19:19:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:19:12 Integrated Voltage Measurement... 19:19:21 Voltage Offset Correction: v_off_ini = 713.416 uV, v_off_fin = 706.359 uV 19:19:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.611 uVs 19:19:21 Integrated Voltage Measurement... 19:19:30 Voltage Offset Correction: v_off_ini = 719.001 uV, v_off_fin = 716.479 uV 19:19:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.098 uVs 19:19:30 Integrated Voltage Measurement... 19:19:39 Voltage Offset Correction: v_off_ini = 714.121 uV, v_off_fin = 708.587 uV 19:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.646 uVs 19:19:39 Integrated Voltage Measurement... 19:19:48 Voltage Offset Correction: v_off_ini = 722.218 uV, v_off_fin = 726.783 uV 19:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.522 uVs 19:19:49 Integrated Voltage Measurement... 19:19:57 Voltage Offset Correction: v_off_ini = 710.236 uV, v_off_fin = 703.595 uV 19:19:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.566 uVs 19:19:58 Integrated Voltage Measurement... 19:20:06 Voltage Offset Correction: v_off_ini = 710.377 uV, v_off_fin = 725.787 uV 19:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.341 uVs 19:20:11 I1Y Average and RMS of Measurements VT = -188.297 +- 2.417 uVs I1Y = -37.659 +- 0.483 uTm 19:20:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:20:18 Integrated Voltage Measurement... 19:20:27 Voltage Offset Correction: v_off_ini = 705.161 uV, v_off_fin = 696.165 uV 19:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.753 uVs 19:20:27 Integrated Voltage Measurement... 19:20:36 Voltage Offset Correction: v_off_ini = 707.847 uV, v_off_fin = 712.219 uV 19:20:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.021 uVs 19:20:37 Integrated Voltage Measurement... 19:20:46 Voltage Offset Correction: v_off_ini = 709.552 uV, v_off_fin = 699.419 uV 19:20:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.825 uVs 19:20:46 Integrated Voltage Measurement... 19:20:55 Voltage Offset Correction: v_off_ini = 711.894 uV, v_off_fin = 711.777 uV 19:20:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.530 uVs 19:20:55 Integrated Voltage Measurement... 19:21:04 Voltage Offset Correction: v_off_ini = 706.456 uV, v_off_fin = 692.232 uV 19:21:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.464 uVs 19:21:04 Integrated Voltage Measurement... 19:21:13 Voltage Offset Correction: v_off_ini = 707.772 uV, v_off_fin = 708.589 uV 19:21:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.363 uVs 19:21:15 I2X Average and RMS of Measurements VT = -51.826 +- 3.646 uVs I2X = 4.768 +- 0.335 uTm^2 19:21:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:21:23 Integrated Voltage Measurement... 19:21:32 Voltage Offset Correction: v_off_ini = 707.383 uV, v_off_fin = 712.824 uV 19:21:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.442 uVs 19:21:32 Integrated Voltage Measurement... 19:21:41 Voltage Offset Correction: v_off_ini = 712.729 uV, v_off_fin = 707.480 uV 19:21:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.746 uVs 19:21:41 Integrated Voltage Measurement... 19:21:50 Voltage Offset Correction: v_off_ini = 703.669 uV, v_off_fin = 711.814 uV 19:21:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -495.072 uVs 19:21:50 Integrated Voltage Measurement... 19:21:59 Voltage Offset Correction: v_off_ini = 707.664 uV, v_off_fin = 709.732 uV 19:21:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 488.336 uVs 19:21:59 Integrated Voltage Measurement... 19:22:08 Voltage Offset Correction: v_off_ini = 712.881 uV, v_off_fin = 702.505 uV 19:22:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.144 uVs 19:22:08 Integrated Voltage Measurement... 19:22:17 Voltage Offset Correction: v_off_ini = 706.350 uV, v_off_fin = 703.349 uV 19:22:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.033 uVs 19:22:19 I2Y Average and RMS of Measurements VT = -490.629 +- 1.443 uVs I2Y = -45.139 +- 0.133 uTm^2 19:22:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:22:31 Integrated Voltage Measurement... 19:22:40 Voltage Offset Correction: v_off_ini = 712.512 uV, v_off_fin = 691.747 uV 19:22:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.450 uVs 19:22:40 Integrated Voltage Measurement... 19:22:49 Voltage Offset Correction: v_off_ini = 692.771 uV, v_off_fin = 690.141 uV 19:22:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.093 uVs 19:22:50 Integrated Voltage Measurement... 19:22:58 Voltage Offset Correction: v_off_ini = 681.581 uV, v_off_fin = 687.106 uV 19:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.826 uVs 19:22:59 Integrated Voltage Measurement... 19:23:08 Voltage Offset Correction: v_off_ini = 688.829 uV, v_off_fin = 690.515 uV 19:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.411 uVs 19:23:08 Integrated Voltage Measurement... 19:23:17 Voltage Offset Correction: v_off_ini = 698.128 uV, v_off_fin = 687.689 uV 19:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.641 uVs 19:23:17 Integrated Voltage Measurement... 19:23:26 Voltage Offset Correction: v_off_ini = 704.824 uV, v_off_fin = 695.857 uV 19:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.267 uVs 19:23:30 I1X Average and RMS of Measurements VT = -60.615 +- 3.788 uVs I1X = 12.123 +- 0.757 uTm 19:23:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:23:37 Integrated Voltage Measurement... 19:23:46 Voltage Offset Correction: v_off_ini = 703.712 uV, v_off_fin = 694.950 uV 19:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.071 uVs 19:23:46 Integrated Voltage Measurement... 19:23:55 Voltage Offset Correction: v_off_ini = 702.730 uV, v_off_fin = 704.970 uV 19:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.941 uVs 19:23:55 Integrated Voltage Measurement... 19:24:04 Voltage Offset Correction: v_off_ini = 695.150 uV, v_off_fin = 696.856 uV 19:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.553 uVs 19:24:04 Integrated Voltage Measurement... 19:24:13 Voltage Offset Correction: v_off_ini = 722.097 uV, v_off_fin = 718.728 uV 19:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.262 uVs 19:24:13 Integrated Voltage Measurement... 19:24:22 Voltage Offset Correction: v_off_ini = 708.552 uV, v_off_fin = 681.347 uV 19:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.152 uVs 19:24:22 Integrated Voltage Measurement... 19:24:31 Voltage Offset Correction: v_off_ini = 692.878 uV, v_off_fin = 706.667 uV 19:24:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.483 uVs 19:24:35 I1Y Average and RMS of Measurements VT = -187.411 +- 4.159 uVs I1Y = -37.482 +- 0.832 uTm 19:24:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:24:40 Integrated Voltage Measurement... 19:24:49 Voltage Offset Correction: v_off_ini = 686.320 uV, v_off_fin = 692.472 uV 19:24:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.707 uVs 19:24:49 Integrated Voltage Measurement... 19:24:58 Voltage Offset Correction: v_off_ini = 691.092 uV, v_off_fin = 694.915 uV 19:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.087 uVs 19:24:58 Integrated Voltage Measurement... 19:25:07 Voltage Offset Correction: v_off_ini = 701.226 uV, v_off_fin = 688.519 uV 19:25:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.346 uVs 19:25:07 Integrated Voltage Measurement... 19:25:16 Voltage Offset Correction: v_off_ini = 705.861 uV, v_off_fin = 713.604 uV 19:25:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.019 uVs 19:25:16 Integrated Voltage Measurement... 19:25:25 Voltage Offset Correction: v_off_ini = 688.792 uV, v_off_fin = 685.828 uV 19:25:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.826 uVs 19:25:25 Integrated Voltage Measurement... 19:25:34 Voltage Offset Correction: v_off_ini = 693.591 uV, v_off_fin = 695.628 uV 19:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.731 uVs 19:25:37 I2X Average and RMS of Measurements VT = -36.786 +- 2.472 uVs I2X = 3.384 +- 0.227 uTm^2 19:25:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:25:42 Integrated Voltage Measurement... 19:25:51 Voltage Offset Correction: v_off_ini = 687.909 uV, v_off_fin = 686.493 uV 19:25:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.902 uVs 19:25:51 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = 694.710 uV, v_off_fin = 681.293 uV 19:26:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.958 uVs 19:26:00 Integrated Voltage Measurement... 19:26:09 Voltage Offset Correction: v_off_ini = 682.178 uV, v_off_fin = 681.978 uV 19:26:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.198 uVs 19:26:09 Integrated Voltage Measurement... 19:26:18 Voltage Offset Correction: v_off_ini = 684.207 uV, v_off_fin = 690.065 uV 19:26:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.460 uVs 19:26:18 Integrated Voltage Measurement... 19:26:27 Voltage Offset Correction: v_off_ini = 680.936 uV, v_off_fin = 679.464 uV 19:26:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.169 uVs 19:26:27 Integrated Voltage Measurement... 19:26:36 Voltage Offset Correction: v_off_ini = 687.707 uV, v_off_fin = 688.938 uV 19:26:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.396 uVs 19:26:38 I2Y Average and RMS of Measurements VT = -481.681 +- 5.365 uVs I2Y = -44.315 +- 0.494 uTm^2 19:26:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:26:47 Integrated Voltage Measurement... 19:26:56 Voltage Offset Correction: v_off_ini = 689.512 uV, v_off_fin = 680.255 uV 19:26:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.901 uVs 19:26:56 Integrated Voltage Measurement... 19:27:05 Voltage Offset Correction: v_off_ini = 679.584 uV, v_off_fin = 686.243 uV 19:27:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.429 uVs 19:27:05 Integrated Voltage Measurement... 19:27:14 Voltage Offset Correction: v_off_ini = 677.784 uV, v_off_fin = 690.772 uV 19:27:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.629 uVs 19:27:14 Integrated Voltage Measurement... 19:27:23 Voltage Offset Correction: v_off_ini = 693.274 uV, v_off_fin = 686.971 uV 19:27:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.596 uVs 19:27:23 Integrated Voltage Measurement... 19:27:32 Voltage Offset Correction: v_off_ini = 688.251 uV, v_off_fin = 683.916 uV 19:27:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.700 uVs 19:27:32 Integrated Voltage Measurement... 19:27:41 Voltage Offset Correction: v_off_ini = 692.474 uV, v_off_fin = 688.684 uV 19:27:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.497 uVs 19:27:45 I1X Average and RMS of Measurements VT = -63.292 +- 1.641 uVs I1X = 12.659 +- 0.328 uTm 19:27:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:27:52 Integrated Voltage Measurement... 19:28:01 Voltage Offset Correction: v_off_ini = 693.231 uV, v_off_fin = 698.849 uV 19:28:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.434 uVs 19:28:01 Integrated Voltage Measurement... 19:28:10 Voltage Offset Correction: v_off_ini = 702.054 uV, v_off_fin = 718.435 uV 19:28:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.981 uVs 19:28:10 Integrated Voltage Measurement... 19:28:19 Voltage Offset Correction: v_off_ini = 708.122 uV, v_off_fin = 692.067 uV 19:28:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.147 uVs 19:28:19 Integrated Voltage Measurement... 19:28:28 Voltage Offset Correction: v_off_ini = 698.542 uV, v_off_fin = 714.571 uV 19:28:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.909 uVs 19:28:28 Integrated Voltage Measurement... 19:28:37 Voltage Offset Correction: v_off_ini = 700.555 uV, v_off_fin = 690.884 uV 19:28:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.264 uVs 19:28:37 Integrated Voltage Measurement... 19:28:46 Voltage Offset Correction: v_off_ini = 696.286 uV, v_off_fin = 709.657 uV 19:28:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.445 uVs 19:28:50 I1Y Average and RMS of Measurements VT = -187.863 +- 3.652 uVs I1Y = -37.573 +- 0.730 uTm 19:28:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:28:55 Integrated Voltage Measurement... 19:29:04 Voltage Offset Correction: v_off_ini = 689.066 uV, v_off_fin = 683.791 uV 19:29:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -52.770 uVs 19:29:04 Integrated Voltage Measurement... 19:29:13 Voltage Offset Correction: v_off_ini = 703.216 uV, v_off_fin = 706.859 uV 19:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.958 uVs 19:29:13 Integrated Voltage Measurement... 19:29:22 Voltage Offset Correction: v_off_ini = 702.930 uV, v_off_fin = 676.060 uV 19:29:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.081 uVs 19:29:22 Integrated Voltage Measurement... 19:29:31 Voltage Offset Correction: v_off_ini = 689.582 uV, v_off_fin = 699.313 uV 19:29:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.900 uVs 19:29:32 Integrated Voltage Measurement... 19:29:40 Voltage Offset Correction: v_off_ini = 697.792 uV, v_off_fin = 686.128 uV 19:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.394 uVs 19:29:41 Integrated Voltage Measurement... 19:29:50 Voltage Offset Correction: v_off_ini = 690.648 uV, v_off_fin = 704.350 uV 19:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.590 uVs 19:29:52 I2X Average and RMS of Measurements VT = -51.282 +- 2.275 uVs I2X = 4.718 +- 0.209 uTm^2 19:29:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:29:57 Integrated Voltage Measurement... 19:30:06 Voltage Offset Correction: v_off_ini = 684.496 uV, v_off_fin = 687.464 uV 19:30:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.211 uVs 19:30:06 Integrated Voltage Measurement... 19:30:15 Voltage Offset Correction: v_off_ini = 690.001 uV, v_off_fin = 693.435 uV 19:30:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.745 uVs 19:30:15 Integrated Voltage Measurement... 19:30:24 Voltage Offset Correction: v_off_ini = 677.733 uV, v_off_fin = 689.999 uV 19:30:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -479.977 uVs 19:30:24 Integrated Voltage Measurement... 19:30:33 Voltage Offset Correction: v_off_ini = 696.173 uV, v_off_fin = 703.079 uV 19:30:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 477.718 uVs 19:30:33 Integrated Voltage Measurement... 19:30:42 Voltage Offset Correction: v_off_ini = 699.693 uV, v_off_fin = 695.029 uV 19:30:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.815 uVs 19:30:42 Integrated Voltage Measurement... 19:30:51 Voltage Offset Correction: v_off_ini = 697.634 uV, v_off_fin = 683.684 uV 19:30:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.319 uVs 19:30:54 I2Y Average and RMS of Measurements VT = -483.798 +- 3.508 uVs I2Y = -44.509 +- 0.323 uTm^2 19:30:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:31:02 Integrated Voltage Measurement... 19:31:11 Voltage Offset Correction: v_off_ini = 684.623 uV, v_off_fin = 688.393 uV 19:31:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.900 uVs 19:31:11 Integrated Voltage Measurement... 19:31:20 Voltage Offset Correction: v_off_ini = 685.863 uV, v_off_fin = 695.359 uV 19:31:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.259 uVs 19:31:20 Integrated Voltage Measurement... 19:31:29 Voltage Offset Correction: v_off_ini = 693.810 uV, v_off_fin = 703.382 uV 19:31:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.533 uVs 19:31:29 Integrated Voltage Measurement... 19:31:38 Voltage Offset Correction: v_off_ini = 706.363 uV, v_off_fin = 702.334 uV 19:31:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.563 uVs 19:31:38 Integrated Voltage Measurement... 19:31:47 Voltage Offset Correction: v_off_ini = 701.131 uV, v_off_fin = 705.795 uV 19:31:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.168 uVs 19:31:47 Integrated Voltage Measurement... 19:31:56 Voltage Offset Correction: v_off_ini = 696.010 uV, v_off_fin = 702.521 uV 19:31:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.632 uVs 19:32:00 I1X Average and RMS of Measurements VT = -63.509 +- 8.847 uVs I1X = 12.703 +- 1.769 uTm 19:32:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:32:07 Integrated Voltage Measurement... 19:32:16 Voltage Offset Correction: v_off_ini = 695.581 uV, v_off_fin = 687.382 uV 19:32:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.057 uVs 19:32:16 Integrated Voltage Measurement... 19:32:25 Voltage Offset Correction: v_off_ini = 681.568 uV, v_off_fin = 699.449 uV 19:32:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.195 uVs 19:32:25 Integrated Voltage Measurement... 19:32:34 Voltage Offset Correction: v_off_ini = 685.403 uV, v_off_fin = 674.318 uV 19:32:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.045 uVs 19:32:34 Integrated Voltage Measurement... 19:32:43 Voltage Offset Correction: v_off_ini = 680.550 uV, v_off_fin = 686.477 uV 19:32:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.660 uVs 19:32:43 Integrated Voltage Measurement... 19:32:52 Voltage Offset Correction: v_off_ini = 702.085 uV, v_off_fin = 696.951 uV 19:32:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.241 uVs 19:32:52 Integrated Voltage Measurement... 19:33:01 Voltage Offset Correction: v_off_ini = 697.421 uV, v_off_fin = 691.605 uV 19:33:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.389 uVs 19:33:05 I1Y Average and RMS of Measurements VT = -195.098 +- 5.710 uVs I1Y = -39.020 +- 1.142 uTm 19:33:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:33:11 Integrated Voltage Measurement... 19:33:20 Voltage Offset Correction: v_off_ini = 670.066 uV, v_off_fin = 676.648 uV 19:33:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.821 uVs 19:33:20 Integrated Voltage Measurement... 19:33:29 Voltage Offset Correction: v_off_ini = 683.723 uV, v_off_fin = 689.469 uV 19:33:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.154 uVs 19:33:29 Integrated Voltage Measurement... 19:33:38 Voltage Offset Correction: v_off_ini = 691.474 uV, v_off_fin = 681.155 uV 19:33:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.587 uVs 19:33:38 Integrated Voltage Measurement... 19:33:47 Voltage Offset Correction: v_off_ini = 691.216 uV, v_off_fin = 691.000 uV 19:33:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.892 uVs 19:33:47 Integrated Voltage Measurement... 19:33:56 Voltage Offset Correction: v_off_ini = 681.896 uV, v_off_fin = 676.553 uV 19:33:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.331 uVs 19:33:56 Integrated Voltage Measurement... 19:34:05 Voltage Offset Correction: v_off_ini = 695.185 uV, v_off_fin = 685.461 uV 19:34:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.542 uVs 19:34:07 I2X Average and RMS of Measurements VT = -48.388 +- 5.917 uVs I2X = 4.452 +- 0.544 uTm^2 19:34:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:34:12 Integrated Voltage Measurement... 19:34:21 Voltage Offset Correction: v_off_ini = 681.995 uV, v_off_fin = 687.041 uV 19:34:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.564 uVs 19:34:21 Integrated Voltage Measurement... 19:34:30 Voltage Offset Correction: v_off_ini = 679.832 uV, v_off_fin = 676.505 uV 19:34:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.214 uVs 19:34:31 Integrated Voltage Measurement... 19:34:39 Voltage Offset Correction: v_off_ini = 686.046 uV, v_off_fin = 684.023 uV 19:34:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -479.983 uVs 19:34:40 Integrated Voltage Measurement... 19:34:49 Voltage Offset Correction: v_off_ini = 669.005 uV, v_off_fin = 678.273 uV 19:34:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.255 uVs 19:34:49 Integrated Voltage Measurement... 19:34:58 Voltage Offset Correction: v_off_ini = 665.427 uV, v_off_fin = 672.791 uV 19:34:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.467 uVs 19:34:58 Integrated Voltage Measurement... 19:35:07 Voltage Offset Correction: v_off_ini = 673.601 uV, v_off_fin = 676.019 uV 19:35:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.843 uVs 19:35:09 I2Y Average and RMS of Measurements VT = -491.388 +- 8.305 uVs I2Y = -45.208 +- 0.764 uTm^2 19:35:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:35:17 Integrated Voltage Measurement... 19:35:26 Voltage Offset Correction: v_off_ini = 699.451 uV, v_off_fin = 691.303 uV 19:35:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -69.969 uVs 19:35:26 Integrated Voltage Measurement... 19:35:35 Voltage Offset Correction: v_off_ini = 672.463 uV, v_off_fin = 676.565 uV 19:35:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.549 uVs 19:35:35 Integrated Voltage Measurement... 19:35:44 Voltage Offset Correction: v_off_ini = 677.395 uV, v_off_fin = 666.991 uV 19:35:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.925 uVs 19:35:44 Integrated Voltage Measurement... 19:35:53 Voltage Offset Correction: v_off_ini = 660.877 uV, v_off_fin = 662.797 uV 19:35:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.019 uVs 19:35:54 Integrated Voltage Measurement... 19:36:02 Voltage Offset Correction: v_off_ini = 674.371 uV, v_off_fin = 671.755 uV 19:36:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.754 uVs 19:36:03 Integrated Voltage Measurement... 19:36:12 Voltage Offset Correction: v_off_ini = 668.527 uV, v_off_fin = 676.918 uV 19:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.600 uVs 19:36:16 I1X Average and RMS of Measurements VT = -80.802 +- 5.049 uVs I1X = 16.161 +- 1.010 uTm 19:36:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:36:23 Integrated Voltage Measurement... 19:36:32 Voltage Offset Correction: v_off_ini = 683.201 uV, v_off_fin = 669.852 uV 19:36:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.735 uVs 19:36:32 Integrated Voltage Measurement... 19:36:41 Voltage Offset Correction: v_off_ini = 676.952 uV, v_off_fin = 685.038 uV 19:36:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.211 uVs 19:36:41 Integrated Voltage Measurement... 19:36:50 Voltage Offset Correction: v_off_ini = 677.899 uV, v_off_fin = 670.683 uV 19:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.463 uVs 19:36:50 Integrated Voltage Measurement... 19:36:59 Voltage Offset Correction: v_off_ini = 678.413 uV, v_off_fin = 688.099 uV 19:36:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.243 uVs 19:36:59 Integrated Voltage Measurement... 19:37:08 Voltage Offset Correction: v_off_ini = 682.205 uV, v_off_fin = 673.632 uV 19:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.374 uVs 19:37:08 Integrated Voltage Measurement... 19:37:17 Voltage Offset Correction: v_off_ini = 683.335 uV, v_off_fin = 696.987 uV 19:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.884 uVs 19:37:21 I1Y Average and RMS of Measurements VT = -187.152 +- 3.901 uVs I1Y = -37.428 +- 0.779 uTm 19:37:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:37:26 Integrated Voltage Measurement... 19:37:35 Voltage Offset Correction: v_off_ini = 691.114 uV, v_off_fin = 687.530 uV 19:37:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.646 uVs 19:37:35 Integrated Voltage Measurement... 19:37:44 Voltage Offset Correction: v_off_ini = 696.669 uV, v_off_fin = 707.138 uV 19:37:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.931 uVs 19:37:44 Integrated Voltage Measurement... 19:37:53 Voltage Offset Correction: v_off_ini = 713.270 uV, v_off_fin = 696.216 uV 19:37:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -53.347 uVs 19:37:53 Integrated Voltage Measurement... 19:38:02 Voltage Offset Correction: v_off_ini = 703.102 uV, v_off_fin = 709.043 uV 19:38:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.931 uVs 19:38:02 Integrated Voltage Measurement... 19:38:11 Voltage Offset Correction: v_off_ini = 689.091 uV, v_off_fin = 687.583 uV 19:38:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.339 uVs 19:38:11 Integrated Voltage Measurement... 19:38:20 Voltage Offset Correction: v_off_ini = 701.525 uV, v_off_fin = 714.298 uV 19:38:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.269 uVs 19:38:22 I2X Average and RMS of Measurements VT = -45.077 +- 10.133 uVs I2X = 4.147 +- 0.932 uTm^2 19:38:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:38:28 Integrated Voltage Measurement... 19:38:37 Voltage Offset Correction: v_off_ini = 701.462 uV, v_off_fin = 712.749 uV 19:38:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.764 uVs 19:38:37 Integrated Voltage Measurement... 19:38:46 Voltage Offset Correction: v_off_ini = 693.056 uV, v_off_fin = 702.968 uV 19:38:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.219 uVs 19:38:46 Integrated Voltage Measurement... 19:38:55 Voltage Offset Correction: v_off_ini = 709.839 uV, v_off_fin = 695.648 uV 19:38:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.171 uVs 19:38:55 Integrated Voltage Measurement... 19:39:04 Voltage Offset Correction: v_off_ini = 699.488 uV, v_off_fin = 700.102 uV 19:39:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.347 uVs 19:39:04 Integrated Voltage Measurement... 19:39:13 Voltage Offset Correction: v_off_ini = 694.304 uV, v_off_fin = 700.799 uV 19:39:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -482.880 uVs 19:39:13 Integrated Voltage Measurement... 19:39:22 Voltage Offset Correction: v_off_ini = 703.981 uV, v_off_fin = 703.887 uV 19:39:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.008 uVs 19:39:24 I2Y Average and RMS of Measurements VT = -494.398 +- 2.685 uVs I2Y = -45.485 +- 0.246 uTm^2 19:39:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:39:32 Integrated Voltage Measurement... 19:39:41 Voltage Offset Correction: v_off_ini = 700.995 uV, v_off_fin = 706.865 uV 19:39:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -65.419 uVs 19:39:42 Integrated Voltage Measurement... 19:39:50 Voltage Offset Correction: v_off_ini = 709.273 uV, v_off_fin = 713.666 uV 19:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.440 uVs 19:39:51 Integrated Voltage Measurement... 19:39:59 Voltage Offset Correction: v_off_ini = 717.558 uV, v_off_fin = 708.379 uV 19:40:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.920 uVs 19:40:00 Integrated Voltage Measurement... 19:40:08 Voltage Offset Correction: v_off_ini = 701.918 uV, v_off_fin = 712.839 uV 19:40:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.612 uVs 19:40:09 Integrated Voltage Measurement... 19:40:17 Voltage Offset Correction: v_off_ini = 705.049 uV, v_off_fin = 700.188 uV 19:40:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.845 uVs 19:40:18 Integrated Voltage Measurement... 19:40:27 Voltage Offset Correction: v_off_ini = 699.499 uV, v_off_fin = 707.009 uV 19:40:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.275 uVs 19:40:31 I1X Average and RMS of Measurements VT = -62.252 +- 9.197 uVs I1X = 12.451 +- 1.839 uTm 19:40:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:40:38 Integrated Voltage Measurement... 19:40:46 Voltage Offset Correction: v_off_ini = 715.959 uV, v_off_fin = 695.397 uV 19:40:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.435 uVs 19:40:46 Integrated Voltage Measurement... 19:40:55 Voltage Offset Correction: v_off_ini = 707.996 uV, v_off_fin = 718.390 uV 19:40:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.811 uVs 19:40:55 Integrated Voltage Measurement... 19:41:04 Voltage Offset Correction: v_off_ini = 703.963 uV, v_off_fin = 702.550 uV 19:41:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -174.667 uVs 19:41:04 Integrated Voltage Measurement... 19:41:13 Voltage Offset Correction: v_off_ini = 694.564 uV, v_off_fin = 711.996 uV 19:41:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.947 uVs 19:41:13 Integrated Voltage Measurement... 19:41:22 Voltage Offset Correction: v_off_ini = 691.960 uV, v_off_fin = 677.945 uV 19:41:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.830 uVs 19:41:22 Integrated Voltage Measurement... 19:41:31 Voltage Offset Correction: v_off_ini = 684.031 uV, v_off_fin = 700.659 uV 19:41:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.577 uVs 19:41:36 I1Y Average and RMS of Measurements VT = -191.878 +- 3.664 uVs I1Y = -38.372 +- 0.732 uTm 19:41:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:41:41 Integrated Voltage Measurement... 19:41:50 Voltage Offset Correction: v_off_ini = 685.246 uV, v_off_fin = 680.424 uV 19:41:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.507 uVs 19:41:50 Integrated Voltage Measurement... 19:41:59 Voltage Offset Correction: v_off_ini = 691.455 uV, v_off_fin = 695.305 uV 19:41:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.977 uVs 19:41:59 Integrated Voltage Measurement... 19:42:08 Voltage Offset Correction: v_off_ini = 692.392 uV, v_off_fin = 679.650 uV 19:42:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.231 uVs 19:42:08 Integrated Voltage Measurement... 19:42:17 Voltage Offset Correction: v_off_ini = 690.551 uV, v_off_fin = 691.836 uV 19:42:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 43.454 uVs 19:42:17 Integrated Voltage Measurement... 19:42:26 Voltage Offset Correction: v_off_ini = 699.833 uV, v_off_fin = 684.689 uV 19:42:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.684 uVs 19:42:26 Integrated Voltage Measurement... 19:42:35 Voltage Offset Correction: v_off_ini = 694.988 uV, v_off_fin = 707.170 uV 19:42:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.418 uVs 19:42:37 I2X Average and RMS of Measurements VT = -42.879 +- 3.640 uVs I2X = 3.945 +- 0.335 uTm^2 19:42:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:42:42 Integrated Voltage Measurement... 19:42:51 Voltage Offset Correction: v_off_ini = 689.314 uV, v_off_fin = 686.180 uV 19:42:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.602 uVs 19:42:51 Integrated Voltage Measurement... 19:43:00 Voltage Offset Correction: v_off_ini = 702.616 uV, v_off_fin = 693.613 uV 19:43:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.374 uVs 19:43:00 Integrated Voltage Measurement... 19:43:09 Voltage Offset Correction: v_off_ini = 696.869 uV, v_off_fin = 702.404 uV 19:43:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.978 uVs 19:43:09 Integrated Voltage Measurement... 19:43:18 Voltage Offset Correction: v_off_ini = 701.422 uV, v_off_fin = 709.818 uV 19:43:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.733 uVs 19:43:19 Integrated Voltage Measurement... 19:43:27 Voltage Offset Correction: v_off_ini = 713.832 uV, v_off_fin = 701.594 uV 19:43:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.966 uVs 19:43:28 Integrated Voltage Measurement... 19:43:37 Voltage Offset Correction: v_off_ini = 702.479 uV, v_off_fin = 703.494 uV 19:43:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 456.717 uVs 19:43:39 I2Y Average and RMS of Measurements VT = -484.395 +- 5.410 uVs I2Y = -44.564 +- 0.498 uTm^2 19:43:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:44:00 Integrated Voltage Measurement... 19:44:09 Voltage Offset Correction: v_off_ini = 700.461 uV, v_off_fin = 695.655 uV 19:44:09 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -71.681 uVs 19:44:09 Integrated Voltage Measurement... 19:44:18 Voltage Offset Correction: v_off_ini = 704.917 uV, v_off_fin = 709.961 uV 19:44:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 81.978 uVs 19:44:18 Integrated Voltage Measurement... 19:44:27 Voltage Offset Correction: v_off_ini = 708.659 uV, v_off_fin = 703.270 uV 19:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.951 uVs 19:44:27 Integrated Voltage Measurement... 19:44:36 Voltage Offset Correction: v_off_ini = 704.503 uV, v_off_fin = 713.290 uV 19:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.535 uVs 19:44:36 Integrated Voltage Measurement... 19:44:45 Voltage Offset Correction: v_off_ini = 704.806 uV, v_off_fin = 705.403 uV 19:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.817 uVs 19:44:45 Integrated Voltage Measurement... 19:44:54 Voltage Offset Correction: v_off_ini = 719.645 uV, v_off_fin = 720.723 uV 19:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.473 uVs 19:44:58 I1X Average and RMS of Measurements VT = -86.073 +- 7.953 uVs I1X = 17.216 +- 1.589 uTm 19:45:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:45:05 Integrated Voltage Measurement... 19:45:14 Voltage Offset Correction: v_off_ini = 708.290 uV, v_off_fin = 697.100 uV 19:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.968 uVs 19:45:14 Integrated Voltage Measurement... 19:45:23 Voltage Offset Correction: v_off_ini = 709.675 uV, v_off_fin = 725.726 uV 19:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.924 uVs 19:45:23 Integrated Voltage Measurement... 19:45:32 Voltage Offset Correction: v_off_ini = 709.015 uV, v_off_fin = 700.750 uV 19:45:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.747 uVs 19:45:32 Integrated Voltage Measurement... 19:45:41 Voltage Offset Correction: v_off_ini = 692.814 uV, v_off_fin = 711.871 uV 19:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.107 uVs 19:45:41 Integrated Voltage Measurement... 19:45:50 Voltage Offset Correction: v_off_ini = 714.296 uV, v_off_fin = 702.088 uV 19:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.720 uVs 19:45:50 Integrated Voltage Measurement... 19:45:59 Voltage Offset Correction: v_off_ini = 709.624 uV, v_off_fin = 718.931 uV 19:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.473 uVs 19:46:03 I1Y Average and RMS of Measurements VT = -197.990 +- 5.698 uVs I1Y = -39.598 +- 1.140 uTm 19:46:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:46:11 Integrated Voltage Measurement... 19:46:20 Voltage Offset Correction: v_off_ini = 692.308 uV, v_off_fin = 693.911 uV 19:46:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.980 uVs 19:46:20 Integrated Voltage Measurement... 19:46:29 Voltage Offset Correction: v_off_ini = 708.344 uV, v_off_fin = 707.487 uV 19:46:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.337 uVs 19:46:29 Integrated Voltage Measurement... 19:46:38 Voltage Offset Correction: v_off_ini = 699.517 uV, v_off_fin = 682.259 uV 19:46:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.827 uVs 19:46:38 Integrated Voltage Measurement... 19:46:47 Voltage Offset Correction: v_off_ini = 688.513 uV, v_off_fin = 695.932 uV 19:46:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.288 uVs 19:46:47 Integrated Voltage Measurement... 19:46:56 Voltage Offset Correction: v_off_ini = 705.537 uV, v_off_fin = 695.843 uV 19:46:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.812 uVs 19:46:56 Integrated Voltage Measurement... 19:47:05 Voltage Offset Correction: v_off_ini = 690.643 uV, v_off_fin = 713.573 uV 19:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.548 uVs 19:47:08 I2X Average and RMS of Measurements VT = -72.299 +- 4.117 uVs I2X = 6.651 +- 0.379 uTm^2 19:47:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:47:15 Integrated Voltage Measurement... 19:47:24 Voltage Offset Correction: v_off_ini = 698.927 uV, v_off_fin = 692.049 uV 19:47:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.954 uVs 19:47:24 Integrated Voltage Measurement... 19:47:33 Voltage Offset Correction: v_off_ini = 688.916 uV, v_off_fin = 693.991 uV 19:47:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.540 uVs 19:47:33 Integrated Voltage Measurement... 19:47:42 Voltage Offset Correction: v_off_ini = 700.271 uV, v_off_fin = 691.735 uV 19:47:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.671 uVs 19:47:42 Integrated Voltage Measurement... 19:47:51 Voltage Offset Correction: v_off_ini = 703.864 uV, v_off_fin = 709.401 uV 19:47:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.902 uVs 19:47:51 Integrated Voltage Measurement... 19:48:00 Voltage Offset Correction: v_off_ini = 699.692 uV, v_off_fin = 702.399 uV 19:48:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -477.817 uVs 19:48:00 Integrated Voltage Measurement... 19:48:09 Voltage Offset Correction: v_off_ini = 709.944 uV, v_off_fin = 707.177 uV 19:48:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.969 uVs 19:48:12 I2Y Average and RMS of Measurements VT = -465.809 +- 2.616 uVs I2Y = -42.854 +- 0.241 uTm^2 19:48:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:48:21 Integrated Voltage Measurement... 19:48:30 Voltage Offset Correction: v_off_ini = 703.531 uV, v_off_fin = 707.639 uV 19:48:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.754 uVs 19:48:30 Integrated Voltage Measurement... 19:48:39 Voltage Offset Correction: v_off_ini = 692.065 uV, v_off_fin = 702.310 uV 19:48:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.453 uVs 19:48:39 Integrated Voltage Measurement... 19:48:48 Voltage Offset Correction: v_off_ini = 700.362 uV, v_off_fin = 708.016 uV 19:48:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.804 uVs 19:48:48 Integrated Voltage Measurement... 19:48:57 Voltage Offset Correction: v_off_ini = 703.849 uV, v_off_fin = 708.003 uV 19:48:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.412 uVs 19:48:57 Integrated Voltage Measurement... 19:49:06 Voltage Offset Correction: v_off_ini = 713.391 uV, v_off_fin = 700.318 uV 19:49:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.629 uVs 19:49:06 Integrated Voltage Measurement... 19:49:15 Voltage Offset Correction: v_off_ini = 701.215 uV, v_off_fin = 702.624 uV 19:49:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.349 uVs 19:49:19 I1X Average and RMS of Measurements VT = -89.067 +- 2.401 uVs I1X = 17.814 +- 0.480 uTm 19:49:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:49:26 Integrated Voltage Measurement... 19:49:35 Voltage Offset Correction: v_off_ini = 703.755 uV, v_off_fin = 699.704 uV 19:49:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.471 uVs 19:49:35 Integrated Voltage Measurement... 19:49:44 Voltage Offset Correction: v_off_ini = 719.098 uV, v_off_fin = 722.147 uV 19:49:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.020 uVs 19:49:44 Integrated Voltage Measurement... 19:49:53 Voltage Offset Correction: v_off_ini = 715.746 uV, v_off_fin = 700.678 uV 19:49:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.735 uVs 19:49:53 Integrated Voltage Measurement... 19:50:02 Voltage Offset Correction: v_off_ini = 709.090 uV, v_off_fin = 718.195 uV 19:50:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.119 uVs 19:50:02 Integrated Voltage Measurement... 19:50:11 Voltage Offset Correction: v_off_ini = 702.990 uV, v_off_fin = 700.749 uV 19:50:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.277 uVs 19:50:11 Integrated Voltage Measurement... 19:50:20 Voltage Offset Correction: v_off_ini = 715.158 uV, v_off_fin = 714.976 uV 19:50:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.623 uVs 19:50:24 I1Y Average and RMS of Measurements VT = -201.208 +- 4.962 uVs I1Y = -40.242 +- 0.992 uTm 19:50:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:50:32 Integrated Voltage Measurement... 19:50:41 Voltage Offset Correction: v_off_ini = 692.384 uV, v_off_fin = 685.123 uV 19:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.355 uVs 19:50:41 Integrated Voltage Measurement... 19:50:50 Voltage Offset Correction: v_off_ini = 700.040 uV, v_off_fin = 707.019 uV 19:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.926 uVs 19:50:50 Integrated Voltage Measurement... 19:50:59 Voltage Offset Correction: v_off_ini = 704.789 uV, v_off_fin = 685.877 uV 19:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.038 uVs 19:50:59 Integrated Voltage Measurement... 19:51:08 Voltage Offset Correction: v_off_ini = 704.551 uV, v_off_fin = 706.842 uV 19:51:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.835 uVs 19:51:08 Integrated Voltage Measurement... 19:51:17 Voltage Offset Correction: v_off_ini = 705.580 uV, v_off_fin = 698.323 uV 19:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.751 uVs 19:51:17 Integrated Voltage Measurement... 19:51:26 Voltage Offset Correction: v_off_ini = 699.029 uV, v_off_fin = 705.190 uV 19:51:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.665 uVs 19:51:29 I2X Average and RMS of Measurements VT = -74.928 +- 4.655 uVs I2X = 6.894 +- 0.428 uTm^2 19:51:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:51:36 Integrated Voltage Measurement... 19:51:45 Voltage Offset Correction: v_off_ini = 690.318 uV, v_off_fin = 704.410 uV 19:51:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.440 uVs 19:51:45 Integrated Voltage Measurement... 19:51:54 Voltage Offset Correction: v_off_ini = 710.421 uV, v_off_fin = 712.629 uV 19:51:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.948 uVs 19:51:54 Integrated Voltage Measurement... 19:52:03 Voltage Offset Correction: v_off_ini = 716.586 uV, v_off_fin = 713.046 uV 19:52:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.131 uVs 19:52:03 Integrated Voltage Measurement... 19:52:12 Voltage Offset Correction: v_off_ini = 699.041 uV, v_off_fin = 709.574 uV 19:52:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.039 uVs 19:52:12 Integrated Voltage Measurement... 19:52:21 Voltage Offset Correction: v_off_ini = 705.239 uV, v_off_fin = 702.578 uV 19:52:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -479.282 uVs 19:52:22 Integrated Voltage Measurement... 19:52:30 Voltage Offset Correction: v_off_ini = 711.627 uV, v_off_fin = 715.354 uV 19:52:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 471.120 uVs 19:52:33 I2Y Average and RMS of Measurements VT = -472.827 +- 7.893 uVs I2Y = -43.500 +- 0.726 uTm^2 19:52:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:52:42 Integrated Voltage Measurement... 19:52:51 Voltage Offset Correction: v_off_ini = 706.458 uV, v_off_fin = 707.497 uV 19:52:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.915 uVs 19:52:51 Integrated Voltage Measurement... 19:53:00 Voltage Offset Correction: v_off_ini = 716.143 uV, v_off_fin = 712.801 uV 19:53:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.702 uVs 19:53:00 Integrated Voltage Measurement... 19:53:09 Voltage Offset Correction: v_off_ini = 708.881 uV, v_off_fin = 688.043 uV 19:53:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.905 uVs 19:53:09 Integrated Voltage Measurement... 19:53:18 Voltage Offset Correction: v_off_ini = 702.839 uV, v_off_fin = 715.962 uV 19:53:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.869 uVs 19:53:18 Integrated Voltage Measurement... 19:53:27 Voltage Offset Correction: v_off_ini = 705.401 uV, v_off_fin = 700.849 uV 19:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.767 uVs 19:53:27 Integrated Voltage Measurement... 19:53:36 Voltage Offset Correction: v_off_ini = 708.106 uV, v_off_fin = 698.337 uV 19:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.495 uVs 19:53:40 I1X Average and RMS of Measurements VT = -86.942 +- 1.414 uVs I1X = 17.389 +- 0.283 uTm 19:53:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:53:47 Integrated Voltage Measurement... 19:53:56 Voltage Offset Correction: v_off_ini = 700.231 uV, v_off_fin = 698.822 uV 19:53:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.496 uVs 19:53:56 Integrated Voltage Measurement... 19:54:05 Voltage Offset Correction: v_off_ini = 701.682 uV, v_off_fin = 710.131 uV 19:54:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.855 uVs 19:54:05 Integrated Voltage Measurement... 19:54:14 Voltage Offset Correction: v_off_ini = 708.925 uV, v_off_fin = 695.841 uV 19:54:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.396 uVs 19:54:14 Integrated Voltage Measurement... 19:54:23 Voltage Offset Correction: v_off_ini = 703.367 uV, v_off_fin = 717.618 uV 19:54:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.899 uVs 19:54:23 Integrated Voltage Measurement... 19:54:32 Voltage Offset Correction: v_off_ini = 711.192 uV, v_off_fin = 694.506 uV 19:54:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.227 uVs 19:54:32 Integrated Voltage Measurement... 19:54:41 Voltage Offset Correction: v_off_ini = 699.921 uV, v_off_fin = 707.120 uV 19:54:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.452 uVs 19:54:45 I1Y Average and RMS of Measurements VT = -195.887 +- 3.592 uVs I1Y = -39.177 +- 0.718 uTm 19:54:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:54:53 Integrated Voltage Measurement... 19:55:02 Voltage Offset Correction: v_off_ini = 692.212 uV, v_off_fin = 696.742 uV 19:55:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.182 uVs 19:55:02 Integrated Voltage Measurement... 19:55:11 Voltage Offset Correction: v_off_ini = 689.675 uV, v_off_fin = 704.890 uV 19:55:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.210 uVs 19:55:11 Integrated Voltage Measurement... 19:55:20 Voltage Offset Correction: v_off_ini = 690.919 uV, v_off_fin = 701.164 uV 19:55:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.261 uVs 19:55:20 Integrated Voltage Measurement... 19:55:29 Voltage Offset Correction: v_off_ini = 706.579 uV, v_off_fin = 703.413 uV 19:55:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.881 uVs 19:55:29 Integrated Voltage Measurement... 19:55:38 Voltage Offset Correction: v_off_ini = 700.989 uV, v_off_fin = 691.979 uV 19:55:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.037 uVs 19:55:38 Integrated Voltage Measurement... 19:55:47 Voltage Offset Correction: v_off_ini = 701.678 uV, v_off_fin = 699.341 uV 19:55:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.902 uVs 19:55:50 I2X Average and RMS of Measurements VT = -74.412 +- 3.719 uVs I2X = 6.846 +- 0.342 uTm^2 19:55:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:55:57 Integrated Voltage Measurement... 19:56:06 Voltage Offset Correction: v_off_ini = 686.169 uV, v_off_fin = 691.579 uV 19:56:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -468.749 uVs 19:56:06 Integrated Voltage Measurement... 19:56:15 Voltage Offset Correction: v_off_ini = 706.350 uV, v_off_fin = 703.189 uV 19:56:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.864 uVs 19:56:15 Integrated Voltage Measurement... 19:56:24 Voltage Offset Correction: v_off_ini = 707.518 uV, v_off_fin = 694.401 uV 19:56:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.232 uVs 19:56:24 Integrated Voltage Measurement... 19:56:33 Voltage Offset Correction: v_off_ini = 694.333 uV, v_off_fin = 692.437 uV 19:56:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.811 uVs 19:56:34 Integrated Voltage Measurement... 19:56:43 Voltage Offset Correction: v_off_ini = 700.522 uV, v_off_fin = 690.189 uV 19:56:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.054 uVs 19:56:43 Integrated Voltage Measurement... 19:56:52 Voltage Offset Correction: v_off_ini = 702.745 uV, v_off_fin = 708.905 uV 19:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 460.931 uVs 19:56:54 I2Y Average and RMS of Measurements VT = -473.107 +- 5.810 uVs I2Y = -43.526 +- 0.535 uTm^2 19:56:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:57:03 Integrated Voltage Measurement... 19:57:12 Voltage Offset Correction: v_off_ini = 700.994 uV, v_off_fin = 715.623 uV 19:57:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -81.430 uVs 19:57:12 Integrated Voltage Measurement... 19:57:21 Voltage Offset Correction: v_off_ini = 710.720 uV, v_off_fin = 708.495 uV 19:57:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.158 uVs 19:57:21 Integrated Voltage Measurement... 19:57:30 Voltage Offset Correction: v_off_ini = 696.086 uV, v_off_fin = 697.056 uV 19:57:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.080 uVs 19:57:30 Integrated Voltage Measurement... 19:57:39 Voltage Offset Correction: v_off_ini = 694.463 uV, v_off_fin = 684.600 uV 19:57:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.712 uVs 19:57:39 Integrated Voltage Measurement... 19:57:48 Voltage Offset Correction: v_off_ini = 680.637 uV, v_off_fin = 679.612 uV 19:57:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.199 uVs 19:57:48 Integrated Voltage Measurement... 19:57:57 Voltage Offset Correction: v_off_ini = 683.868 uV, v_off_fin = 689.600 uV 19:57:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.277 uVs 19:58:01 I1X Average and RMS of Measurements VT = -77.310 +- 4.484 uVs I1X = 15.463 +- 0.897 uTm 19:58:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:58:08 Integrated Voltage Measurement... 19:58:17 Voltage Offset Correction: v_off_ini = 680.019 uV, v_off_fin = 669.181 uV 19:58:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -199.983 uVs 19:58:17 Integrated Voltage Measurement... 19:58:26 Voltage Offset Correction: v_off_ini = 682.657 uV, v_off_fin = 684.652 uV 19:58:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.725 uVs 19:58:26 Integrated Voltage Measurement... 19:58:35 Voltage Offset Correction: v_off_ini = 682.429 uV, v_off_fin = 672.662 uV 19:58:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.294 uVs 19:58:35 Integrated Voltage Measurement... 19:58:44 Voltage Offset Correction: v_off_ini = 672.588 uV, v_off_fin = 696.258 uV 19:58:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.975 uVs 19:58:44 Integrated Voltage Measurement... 19:58:53 Voltage Offset Correction: v_off_ini = 688.141 uV, v_off_fin = 677.004 uV 19:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.861 uVs 19:58:53 Integrated Voltage Measurement... 19:59:02 Voltage Offset Correction: v_off_ini = 678.652 uV, v_off_fin = 691.894 uV 19:59:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.115 uVs 19:59:06 I1Y Average and RMS of Measurements VT = -202.325 +- 3.450 uVs I1Y = -40.466 +- 0.691 uTm 19:59:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:59:14 Integrated Voltage Measurement... 19:59:23 Voltage Offset Correction: v_off_ini = 658.969 uV, v_off_fin = 663.780 uV 19:59:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.467 uVs 19:59:23 Integrated Voltage Measurement... 19:59:32 Voltage Offset Correction: v_off_ini = 662.768 uV, v_off_fin = 673.113 uV 19:59:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.057 uVs 19:59:32 Integrated Voltage Measurement... 19:59:41 Voltage Offset Correction: v_off_ini = 671.551 uV, v_off_fin = 670.222 uV 19:59:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.298 uVs 19:59:41 Integrated Voltage Measurement... 19:59:50 Voltage Offset Correction: v_off_ini = 665.022 uV, v_off_fin = 679.816 uV 19:59:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.366 uVs 19:59:50 Integrated Voltage Measurement... 19:59:59 Voltage Offset Correction: v_off_ini = 665.254 uV, v_off_fin = 654.574 uV 19:59:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.468 uVs 19:59:59 Integrated Voltage Measurement... 20:00:08 Voltage Offset Correction: v_off_ini = 680.856 uV, v_off_fin = 678.047 uV 20:00:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.710 uVs 20:00:11 I2X Average and RMS of Measurements VT = -69.894 +- 1.107 uVs I2X = 6.430 +- 0.102 uTm^2 20:00:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:00:18 Integrated Voltage Measurement... 20:00:27 Voltage Offset Correction: v_off_ini = 665.948 uV, v_off_fin = 674.421 uV 20:00:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.762 uVs 20:00:27 Integrated Voltage Measurement... 20:00:36 Voltage Offset Correction: v_off_ini = 674.086 uV, v_off_fin = 668.488 uV 20:00:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.386 uVs 20:00:37 Integrated Voltage Measurement... 20:00:45 Voltage Offset Correction: v_off_ini = 661.517 uV, v_off_fin = 678.396 uV 20:00:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -477.204 uVs 20:00:46 Integrated Voltage Measurement... 20:00:55 Voltage Offset Correction: v_off_ini = 667.014 uV, v_off_fin = 667.812 uV 20:00:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.148 uVs 20:00:55 Integrated Voltage Measurement... 20:01:04 Voltage Offset Correction: v_off_ini = 655.992 uV, v_off_fin = 661.773 uV 20:01:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -481.844 uVs 20:01:04 Integrated Voltage Measurement... 20:01:13 Voltage Offset Correction: v_off_ini = 658.207 uV, v_off_fin = 657.990 uV 20:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.432 uVs 20:01:15 I2Y Average and RMS of Measurements VT = -479.129 +- 2.566 uVs I2Y = -44.081 +- 0.237 uTm^2 20:01:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:01:24 Integrated Voltage Measurement... 20:01:33 Voltage Offset Correction: v_off_ini = 664.558 uV, v_off_fin = 653.274 uV 20:01:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.484 uVs 20:01:33 Integrated Voltage Measurement... 20:01:42 Voltage Offset Correction: v_off_ini = 649.490 uV, v_off_fin = 664.030 uV 20:01:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.138 uVs 20:01:42 Integrated Voltage Measurement... 20:01:51 Voltage Offset Correction: v_off_ini = 659.600 uV, v_off_fin = 658.929 uV 20:01:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.260 uVs 20:01:51 Integrated Voltage Measurement... 20:02:00 Voltage Offset Correction: v_off_ini = 657.846 uV, v_off_fin = 646.154 uV 20:02:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.930 uVs 20:02:00 Integrated Voltage Measurement... 20:02:09 Voltage Offset Correction: v_off_ini = 649.047 uV, v_off_fin = 648.674 uV 20:02:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.612 uVs 20:02:09 Integrated Voltage Measurement... 20:02:18 Voltage Offset Correction: v_off_ini = 653.788 uV, v_off_fin = 659.294 uV 20:02:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.583 uVs 20:02:22 I1X Average and RMS of Measurements VT = -97.334 +- 7.627 uVs I1X = 19.468 +- 1.526 uTm 20:02:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:02:29 Integrated Voltage Measurement... 20:02:38 Voltage Offset Correction: v_off_ini = 652.341 uV, v_off_fin = 640.649 uV 20:02:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.904 uVs 20:02:38 Integrated Voltage Measurement... 20:02:47 Voltage Offset Correction: v_off_ini = 640.397 uV, v_off_fin = 652.717 uV 20:02:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.295 uVs 20:02:47 Integrated Voltage Measurement... 20:02:56 Voltage Offset Correction: v_off_ini = 659.673 uV, v_off_fin = 655.390 uV 20:02:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.499 uVs 20:02:56 Integrated Voltage Measurement... 20:03:05 Voltage Offset Correction: v_off_ini = 664.207 uV, v_off_fin = 662.306 uV 20:03:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.109 uVs 20:03:05 Integrated Voltage Measurement... 20:03:14 Voltage Offset Correction: v_off_ini = 645.304 uV, v_off_fin = 622.684 uV 20:03:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.965 uVs 20:03:14 Integrated Voltage Measurement... 20:03:23 Voltage Offset Correction: v_off_ini = 645.740 uV, v_off_fin = 660.143 uV 20:03:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.041 uVs 20:03:27 I1Y Average and RMS of Measurements VT = -194.135 +- 5.054 uVs I1Y = -38.827 +- 1.011 uTm 20:03:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:03:35 Integrated Voltage Measurement... 20:03:44 Voltage Offset Correction: v_off_ini = 647.661 uV, v_off_fin = 642.482 uV 20:03:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.039 uVs 20:03:44 Integrated Voltage Measurement... 20:03:53 Voltage Offset Correction: v_off_ini = 636.285 uV, v_off_fin = 649.229 uV 20:03:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.049 uVs 20:03:53 Integrated Voltage Measurement... 20:04:02 Voltage Offset Correction: v_off_ini = 647.976 uV, v_off_fin = 636.453 uV 20:04:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.030 uVs 20:04:02 Integrated Voltage Measurement... 20:04:11 Voltage Offset Correction: v_off_ini = 645.483 uV, v_off_fin = 651.841 uV 20:04:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.129 uVs 20:04:11 Integrated Voltage Measurement... 20:04:20 Voltage Offset Correction: v_off_ini = 644.917 uV, v_off_fin = 643.888 uV 20:04:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.678 uVs 20:04:20 Integrated Voltage Measurement... 20:04:29 Voltage Offset Correction: v_off_ini = 653.417 uV, v_off_fin = 657.232 uV 20:04:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.620 uVs 20:04:32 I2X Average and RMS of Measurements VT = -67.924 +- 10.407 uVs I2X = 6.249 +- 0.957 uTm^2 20:04:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:04:40 Integrated Voltage Measurement... 20:04:49 Voltage Offset Correction: v_off_ini = 647.132 uV, v_off_fin = 652.910 uV 20:04:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -487.325 uVs 20:04:49 Integrated Voltage Measurement... 20:04:58 Voltage Offset Correction: v_off_ini = 653.291 uV, v_off_fin = 658.437 uV 20:04:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.315 uVs 20:04:58 Integrated Voltage Measurement... 20:05:07 Voltage Offset Correction: v_off_ini = 669.521 uV, v_off_fin = 664.391 uV 20:05:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.548 uVs 20:05:07 Integrated Voltage Measurement... 20:05:16 Voltage Offset Correction: v_off_ini = 667.659 uV, v_off_fin = 670.408 uV 20:05:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.846 uVs 20:05:16 Integrated Voltage Measurement... 20:05:25 Voltage Offset Correction: v_off_ini = 650.441 uV, v_off_fin = 661.052 uV 20:05:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -471.950 uVs 20:05:25 Integrated Voltage Measurement... 20:05:34 Voltage Offset Correction: v_off_ini = 654.557 uV, v_off_fin = 653.987 uV 20:05:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.458 uVs 20:05:36 I2Y Average and RMS of Measurements VT = -471.407 +- 1.484 uVs I2Y = -43.369 +- 0.136 uTm^2 20:05:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:05:48 Integrated Voltage Measurement... 20:05:57 Voltage Offset Correction: v_off_ini = 672.442 uV, v_off_fin = 655.542 uV 20:05:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.361 uVs 20:05:57 Integrated Voltage Measurement... 20:06:06 Voltage Offset Correction: v_off_ini = 664.742 uV, v_off_fin = 663.698 uV 20:06:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.613 uVs 20:06:06 Integrated Voltage Measurement... 20:06:15 Voltage Offset Correction: v_off_ini = 658.163 uV, v_off_fin = 651.843 uV 20:06:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.120 uVs 20:06:15 Integrated Voltage Measurement... 20:06:24 Voltage Offset Correction: v_off_ini = 653.745 uV, v_off_fin = 656.793 uV 20:06:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.580 uVs 20:06:24 Integrated Voltage Measurement... 20:06:33 Voltage Offset Correction: v_off_ini = 660.629 uV, v_off_fin = 665.201 uV 20:06:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.090 uVs 20:06:33 Integrated Voltage Measurement... 20:06:42 Voltage Offset Correction: v_off_ini = 661.159 uV, v_off_fin = 664.003 uV 20:06:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.669 uVs 20:06:47 I1X Average and RMS of Measurements VT = -73.906 +- 1.376 uVs I1X = 14.781 +- 0.275 uTm 20:06:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:06:53 Integrated Voltage Measurement... 20:07:02 Voltage Offset Correction: v_off_ini = 652.229 uV, v_off_fin = 646.179 uV 20:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.166 uVs 20:07:02 Integrated Voltage Measurement... 20:07:11 Voltage Offset Correction: v_off_ini = 653.284 uV, v_off_fin = 659.353 uV 20:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.323 uVs 20:07:11 Integrated Voltage Measurement... 20:07:20 Voltage Offset Correction: v_off_ini = 655.893 uV, v_off_fin = 640.180 uV 20:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.685 uVs 20:07:20 Integrated Voltage Measurement... 20:07:29 Voltage Offset Correction: v_off_ini = 659.276 uV, v_off_fin = 661.403 uV 20:07:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.563 uVs 20:07:29 Integrated Voltage Measurement... 20:07:38 Voltage Offset Correction: v_off_ini = 663.393 uV, v_off_fin = 647.523 uV 20:07:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.440 uVs 20:07:38 Integrated Voltage Measurement... 20:07:47 Voltage Offset Correction: v_off_ini = 661.852 uV, v_off_fin = 661.952 uV 20:07:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.937 uVs 20:07:52 I1Y Average and RMS of Measurements VT = -196.186 +- 4.498 uVs I1Y = -39.237 +- 0.900 uTm 20:07:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:07:57 Integrated Voltage Measurement... 20:08:06 Voltage Offset Correction: v_off_ini = 652.264 uV, v_off_fin = 652.887 uV 20:08:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.047 uVs 20:08:06 Integrated Voltage Measurement... 20:08:15 Voltage Offset Correction: v_off_ini = 661.942 uV, v_off_fin = 669.168 uV 20:08:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.189 uVs 20:08:15 Integrated Voltage Measurement... 20:08:24 Voltage Offset Correction: v_off_ini = 653.395 uV, v_off_fin = 652.958 uV 20:08:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.021 uVs 20:08:24 Integrated Voltage Measurement... 20:08:33 Voltage Offset Correction: v_off_ini = 670.764 uV, v_off_fin = 671.257 uV 20:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.514 uVs 20:08:33 Integrated Voltage Measurement... 20:08:42 Voltage Offset Correction: v_off_ini = 664.607 uV, v_off_fin = 661.302 uV 20:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.739 uVs 20:08:42 Integrated Voltage Measurement... 20:08:51 Voltage Offset Correction: v_off_ini = 670.087 uV, v_off_fin = 670.484 uV 20:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.584 uVs 20:08:53 I2X Average and RMS of Measurements VT = -58.849 +- 2.557 uVs I2X = 5.414 +- 0.235 uTm^2 20:08:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:08:58 Integrated Voltage Measurement... 20:09:07 Voltage Offset Correction: v_off_ini = 660.305 uV, v_off_fin = 662.941 uV 20:09:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.163 uVs 20:09:08 Integrated Voltage Measurement... 20:09:17 Voltage Offset Correction: v_off_ini = 655.860 uV, v_off_fin = 667.431 uV 20:09:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.749 uVs 20:09:17 Integrated Voltage Measurement... 20:09:26 Voltage Offset Correction: v_off_ini = 651.913 uV, v_off_fin = 643.407 uV 20:09:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.751 uVs 20:09:26 Integrated Voltage Measurement... 20:09:35 Voltage Offset Correction: v_off_ini = 656.392 uV, v_off_fin = 660.977 uV 20:09:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.692 uVs 20:09:35 Integrated Voltage Measurement... 20:09:44 Voltage Offset Correction: v_off_ini = 659.519 uV, v_off_fin = 651.274 uV 20:09:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -463.562 uVs 20:09:44 Integrated Voltage Measurement... 20:09:53 Voltage Offset Correction: v_off_ini = 656.005 uV, v_off_fin = 649.267 uV 20:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 476.477 uVs 20:09:55 I2Y Average and RMS of Measurements VT = -474.732 +- 3.514 uVs I2Y = -43.676 +- 0.322 uTm^2 20:09:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:10:03 Integrated Voltage Measurement... 20:10:12 Voltage Offset Correction: v_off_ini = 664.213 uV, v_off_fin = 665.861 uV 20:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.903 uVs 20:10:13 Integrated Voltage Measurement... 20:10:21 Voltage Offset Correction: v_off_ini = 675.191 uV, v_off_fin = 676.972 uV 20:10:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.990 uVs 20:10:22 Integrated Voltage Measurement... 20:10:31 Voltage Offset Correction: v_off_ini = 671.257 uV, v_off_fin = 673.068 uV 20:10:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.203 uVs 20:10:31 Integrated Voltage Measurement... 20:10:40 Voltage Offset Correction: v_off_ini = 688.133 uV, v_off_fin = 699.687 uV 20:10:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.247 uVs 20:10:40 Integrated Voltage Measurement... 20:10:49 Voltage Offset Correction: v_off_ini = 696.498 uV, v_off_fin = 699.215 uV 20:10:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -88.632 uVs 20:10:49 Integrated Voltage Measurement... 20:10:58 Voltage Offset Correction: v_off_ini = 699.328 uV, v_off_fin = 704.038 uV 20:10:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.247 uVs 20:11:02 I1X Average and RMS of Measurements VT = -81.370 +- 5.996 uVs I1X = 16.275 +- 1.199 uTm 20:11:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:11:09 Integrated Voltage Measurement... 20:11:18 Voltage Offset Correction: v_off_ini = 697.008 uV, v_off_fin = 685.412 uV 20:11:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -191.826 uVs 20:11:18 Integrated Voltage Measurement... 20:11:27 Voltage Offset Correction: v_off_ini = 692.961 uV, v_off_fin = 697.809 uV 20:11:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.198 uVs 20:11:27 Integrated Voltage Measurement... 20:11:36 Voltage Offset Correction: v_off_ini = 687.817 uV, v_off_fin = 676.372 uV 20:11:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.576 uVs 20:11:36 Integrated Voltage Measurement... 20:11:45 Voltage Offset Correction: v_off_ini = 698.409 uV, v_off_fin = 697.537 uV 20:11:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.848 uVs 20:11:45 Integrated Voltage Measurement... 20:11:54 Voltage Offset Correction: v_off_ini = 687.239 uV, v_off_fin = 673.279 uV 20:11:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.926 uVs 20:11:54 Integrated Voltage Measurement... 20:12:03 Voltage Offset Correction: v_off_ini = 676.410 uV, v_off_fin = 691.328 uV 20:12:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.208 uVs 20:12:07 I1Y Average and RMS of Measurements VT = -191.097 +- 1.556 uVs I1Y = -38.221 +- 0.310 uTm 20:12:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:12:12 Integrated Voltage Measurement... 20:12:21 Voltage Offset Correction: v_off_ini = 675.472 uV, v_off_fin = 676.053 uV 20:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.154 uVs 20:12:21 Integrated Voltage Measurement... 20:12:30 Voltage Offset Correction: v_off_ini = 672.620 uV, v_off_fin = 683.000 uV 20:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.346 uVs 20:12:30 Integrated Voltage Measurement... 20:12:39 Voltage Offset Correction: v_off_ini = 674.281 uV, v_off_fin = 658.523 uV 20:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.081 uVs 20:12:39 Integrated Voltage Measurement... 20:12:48 Voltage Offset Correction: v_off_ini = 662.893 uV, v_off_fin = 661.779 uV 20:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.121 uVs 20:12:48 Integrated Voltage Measurement... 20:12:57 Voltage Offset Correction: v_off_ini = 661.756 uV, v_off_fin = 658.450 uV 20:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.492 uVs 20:12:57 Integrated Voltage Measurement... 20:13:06 Voltage Offset Correction: v_off_ini = 678.254 uV, v_off_fin = 678.938 uV 20:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.404 uVs 20:13:09 I2X Average and RMS of Measurements VT = -69.933 +- 4.185 uVs I2X = 6.434 +- 0.385 uTm^2 20:13:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:13:14 Integrated Voltage Measurement... 20:13:23 Voltage Offset Correction: v_off_ini = 674.984 uV, v_off_fin = 670.542 uV 20:13:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.193 uVs 20:13:23 Integrated Voltage Measurement... 20:13:32 Voltage Offset Correction: v_off_ini = 670.634 uV, v_off_fin = 676.801 uV 20:13:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.743 uVs 20:13:32 Integrated Voltage Measurement... 20:13:41 Voltage Offset Correction: v_off_ini = 669.784 uV, v_off_fin = 680.865 uV 20:13:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.348 uVs 20:13:41 Integrated Voltage Measurement... 20:13:50 Voltage Offset Correction: v_off_ini = 680.749 uV, v_off_fin = 681.286 uV 20:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 466.100 uVs 20:13:50 Integrated Voltage Measurement... 20:13:59 Voltage Offset Correction: v_off_ini = 681.624 uV, v_off_fin = 674.000 uV 20:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.648 uVs 20:13:59 Integrated Voltage Measurement... 20:14:08 Voltage Offset Correction: v_off_ini = 666.835 uV, v_off_fin = 675.464 uV 20:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.930 uVs 20:14:10 I2Y Average and RMS of Measurements VT = -471.494 +- 3.488 uVs I2Y = -43.377 +- 0.321 uTm^2 20:14:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:14:19 Integrated Voltage Measurement... 20:14:28 Voltage Offset Correction: v_off_ini = 668.524 uV, v_off_fin = 670.326 uV 20:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.507 uVs 20:14:28 Integrated Voltage Measurement... 20:14:37 Voltage Offset Correction: v_off_ini = 658.309 uV, v_off_fin = 673.721 uV 20:14:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.075 uVs 20:14:37 Integrated Voltage Measurement... 20:14:46 Voltage Offset Correction: v_off_ini = 666.774 uV, v_off_fin = 666.827 uV 20:14:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.578 uVs 20:14:46 Integrated Voltage Measurement... 20:14:55 Voltage Offset Correction: v_off_ini = 677.880 uV, v_off_fin = 665.378 uV 20:14:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.319 uVs 20:14:55 Integrated Voltage Measurement... 20:15:04 Voltage Offset Correction: v_off_ini = 657.147 uV, v_off_fin = 660.331 uV 20:15:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.788 uVs 20:15:04 Integrated Voltage Measurement... 20:15:13 Voltage Offset Correction: v_off_ini = 655.771 uV, v_off_fin = 656.503 uV 20:15:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.733 uVs 20:15:17 I1X Average and RMS of Measurements VT = -75.333 +- 6.403 uVs I1X = 15.067 +- 1.281 uTm 20:15:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:15:24 Integrated Voltage Measurement... 20:15:33 Voltage Offset Correction: v_off_ini = 660.845 uV, v_off_fin = 654.462 uV 20:15:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -201.851 uVs 20:15:33 Integrated Voltage Measurement... 20:15:42 Voltage Offset Correction: v_off_ini = 658.406 uV, v_off_fin = 662.415 uV 20:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.281 uVs 20:15:42 Integrated Voltage Measurement... 20:15:51 Voltage Offset Correction: v_off_ini = 658.635 uV, v_off_fin = 648.250 uV 20:15:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.573 uVs 20:15:51 Integrated Voltage Measurement... 20:16:00 Voltage Offset Correction: v_off_ini = 649.485 uV, v_off_fin = 667.794 uV 20:16:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.694 uVs 20:16:00 Integrated Voltage Measurement... 20:16:09 Voltage Offset Correction: v_off_ini = 672.286 uV, v_off_fin = 650.383 uV 20:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.457 uVs 20:16:09 Integrated Voltage Measurement... 20:16:18 Voltage Offset Correction: v_off_ini = 661.142 uV, v_off_fin = 668.607 uV 20:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.610 uVs 20:16:22 I1Y Average and RMS of Measurements VT = -193.244 +- 3.514 uVs I1Y = -38.649 +- 0.700 uTm 20:16:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:16:27 Integrated Voltage Measurement... 20:16:36 Voltage Offset Correction: v_off_ini = 650.588 uV, v_off_fin = 649.321 uV 20:16:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.862 uVs 20:16:36 Integrated Voltage Measurement... 20:16:45 Voltage Offset Correction: v_off_ini = 658.734 uV, v_off_fin = 665.403 uV 20:16:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.120 uVs 20:16:45 Integrated Voltage Measurement... 20:16:54 Voltage Offset Correction: v_off_ini = 662.913 uV, v_off_fin = 643.969 uV 20:16:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.616 uVs 20:16:54 Integrated Voltage Measurement... 20:17:03 Voltage Offset Correction: v_off_ini = 662.367 uV, v_off_fin = 669.103 uV 20:17:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.083 uVs 20:17:03 Integrated Voltage Measurement... 20:17:12 Voltage Offset Correction: v_off_ini = 669.922 uV, v_off_fin = 641.198 uV 20:17:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.591 uVs 20:17:12 Integrated Voltage Measurement... 20:17:21 Voltage Offset Correction: v_off_ini = 664.559 uV, v_off_fin = 662.870 uV 20:17:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.629 uVs 20:17:24 I2X Average and RMS of Measurements VT = -70.650 +- 4.217 uVs I2X = 6.500 +- 0.388 uTm^2 20:17:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:17:29 Integrated Voltage Measurement... 20:17:38 Voltage Offset Correction: v_off_ini = 655.369 uV, v_off_fin = 664.040 uV 20:17:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -457.252 uVs 20:17:38 Integrated Voltage Measurement... 20:17:47 Voltage Offset Correction: v_off_ini = 652.883 uV, v_off_fin = 656.924 uV 20:17:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.489 uVs 20:17:47 Integrated Voltage Measurement... 20:17:56 Voltage Offset Correction: v_off_ini = 655.337 uV, v_off_fin = 656.654 uV 20:17:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.559 uVs 20:17:56 Integrated Voltage Measurement... 20:18:05 Voltage Offset Correction: v_off_ini = 648.212 uV, v_off_fin = 660.657 uV 20:18:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.807 uVs 20:18:05 Integrated Voltage Measurement... 20:18:14 Voltage Offset Correction: v_off_ini = 661.087 uV, v_off_fin = 653.400 uV 20:18:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.796 uVs 20:18:14 Integrated Voltage Measurement... 20:18:23 Voltage Offset Correction: v_off_ini = 653.125 uV, v_off_fin = 634.976 uV 20:18:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.862 uVs 20:18:26 I2Y Average and RMS of Measurements VT = -470.961 +- 2.787 uVs I2Y = -43.329 +- 0.256 uTm^2 20:18:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:18:34 Integrated Voltage Measurement... 20:18:43 Voltage Offset Correction: v_off_ini = 660.918 uV, v_off_fin = 655.129 uV 20:18:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.784 uVs 20:18:43 Integrated Voltage Measurement... 20:18:52 Voltage Offset Correction: v_off_ini = 661.662 uV, v_off_fin = 668.375 uV 20:18:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.959 uVs 20:18:52 Integrated Voltage Measurement... 20:19:01 Voltage Offset Correction: v_off_ini = 662.123 uV, v_off_fin = 670.042 uV 20:19:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.859 uVs 20:19:01 Integrated Voltage Measurement... 20:19:10 Voltage Offset Correction: v_off_ini = 649.915 uV, v_off_fin = 658.921 uV 20:19:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.151 uVs 20:19:10 Integrated Voltage Measurement... 20:19:19 Voltage Offset Correction: v_off_ini = 656.436 uV, v_off_fin = 656.584 uV 20:19:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.149 uVs 20:19:19 Integrated Voltage Measurement... 20:19:28 Voltage Offset Correction: v_off_ini = 661.935 uV, v_off_fin = 668.191 uV 20:19:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.895 uVs 20:19:32 I1X Average and RMS of Measurements VT = -85.800 +- 4.299 uVs I1X = 17.160 +- 0.860 uTm 20:19:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:19:39 Integrated Voltage Measurement... 20:19:48 Voltage Offset Correction: v_off_ini = 660.208 uV, v_off_fin = 659.947 uV 20:19:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.210 uVs 20:19:48 Integrated Voltage Measurement... 20:19:57 Voltage Offset Correction: v_off_ini = 673.893 uV, v_off_fin = 679.452 uV 20:19:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.844 uVs 20:19:57 Integrated Voltage Measurement... 20:20:06 Voltage Offset Correction: v_off_ini = 666.057 uV, v_off_fin = 661.549 uV 20:20:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.868 uVs 20:20:06 Integrated Voltage Measurement... 20:20:15 Voltage Offset Correction: v_off_ini = 663.314 uV, v_off_fin = 679.839 uV 20:20:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.767 uVs 20:20:15 Integrated Voltage Measurement... 20:20:24 Voltage Offset Correction: v_off_ini = 683.583 uV, v_off_fin = 666.252 uV 20:20:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.061 uVs 20:20:24 Integrated Voltage Measurement... 20:20:33 Voltage Offset Correction: v_off_ini = 681.943 uV, v_off_fin = 682.954 uV 20:20:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.893 uVs 20:20:38 I1Y Average and RMS of Measurements VT = -200.107 +- 4.168 uVs I1Y = -40.020 +- 0.833 uTm 20:20:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:20:43 Integrated Voltage Measurement... 20:20:52 Voltage Offset Correction: v_off_ini = 661.598 uV, v_off_fin = 661.173 uV 20:20:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.051 uVs 20:20:52 Integrated Voltage Measurement... 20:21:01 Voltage Offset Correction: v_off_ini = 669.111 uV, v_off_fin = 678.220 uV 20:21:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.902 uVs 20:21:01 Integrated Voltage Measurement... 20:21:10 Voltage Offset Correction: v_off_ini = 682.547 uV, v_off_fin = 670.711 uV 20:21:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.363 uVs 20:21:10 Integrated Voltage Measurement... 20:21:19 Voltage Offset Correction: v_off_ini = 667.854 uV, v_off_fin = 688.920 uV 20:21:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.799 uVs 20:21:19 Integrated Voltage Measurement... 20:21:28 Voltage Offset Correction: v_off_ini = 686.311 uV, v_off_fin = 668.480 uV 20:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.028 uVs 20:21:28 Integrated Voltage Measurement... 20:21:37 Voltage Offset Correction: v_off_ini = 686.733 uV, v_off_fin = 690.735 uV 20:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.321 uVs 20:21:39 I2X Average and RMS of Measurements VT = -61.911 +- 6.486 uVs I2X = 5.696 +- 0.597 uTm^2 20:21:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:21:44 Integrated Voltage Measurement... 20:21:53 Voltage Offset Correction: v_off_ini = 679.608 uV, v_off_fin = 683.889 uV 20:21:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.192 uVs 20:21:53 Integrated Voltage Measurement... 20:22:02 Voltage Offset Correction: v_off_ini = 673.509 uV, v_off_fin = 683.711 uV 20:22:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.733 uVs 20:22:03 Integrated Voltage Measurement... 20:22:12 Voltage Offset Correction: v_off_ini = 683.423 uV, v_off_fin = 683.435 uV 20:22:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.848 uVs 20:22:12 Integrated Voltage Measurement... 20:22:21 Voltage Offset Correction: v_off_ini = 679.546 uV, v_off_fin = 675.219 uV 20:22:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.885 uVs 20:22:21 Integrated Voltage Measurement... 20:22:30 Voltage Offset Correction: v_off_ini = 679.429 uV, v_off_fin = 666.808 uV 20:22:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.631 uVs 20:22:30 Integrated Voltage Measurement... 20:22:39 Voltage Offset Correction: v_off_ini = 678.508 uV, v_off_fin = 672.663 uV 20:22:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.557 uVs 20:22:41 I2Y Average and RMS of Measurements VT = -473.974 +- 4.951 uVs I2Y = -43.606 +- 0.456 uTm^2 20:22:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:22:49 Integrated Voltage Measurement... 20:22:58 Voltage Offset Correction: v_off_ini = 690.553 uV, v_off_fin = 682.815 uV 20:22:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -89.434 uVs 20:22:59 Integrated Voltage Measurement... 20:23:07 Voltage Offset Correction: v_off_ini = 692.456 uV, v_off_fin = 683.357 uV 20:23:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.518 uVs 20:23:08 Integrated Voltage Measurement... 20:23:16 Voltage Offset Correction: v_off_ini = 696.007 uV, v_off_fin = 675.425 uV 20:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.543 uVs 20:23:17 Integrated Voltage Measurement... 20:23:26 Voltage Offset Correction: v_off_ini = 676.994 uV, v_off_fin = 678.160 uV 20:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.007 uVs 20:23:26 Integrated Voltage Measurement... 20:23:35 Voltage Offset Correction: v_off_ini = 670.798 uV, v_off_fin = 668.046 uV 20:23:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.035 uVs 20:23:35 Integrated Voltage Measurement... 20:23:44 Voltage Offset Correction: v_off_ini = 682.525 uV, v_off_fin = 673.348 uV 20:23:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.981 uVs 20:23:48 I1X Average and RMS of Measurements VT = -72.586 +- 5.503 uVs I1X = 14.518 +- 1.102 uTm 20:23:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:23:55 Integrated Voltage Measurement... 20:24:04 Voltage Offset Correction: v_off_ini = 672.655 uV, v_off_fin = 661.968 uV 20:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.543 uVs 20:24:04 Integrated Voltage Measurement... 20:24:13 Voltage Offset Correction: v_off_ini = 667.241 uV, v_off_fin = 679.343 uV 20:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.902 uVs 20:24:13 Integrated Voltage Measurement... 20:24:22 Voltage Offset Correction: v_off_ini = 678.549 uV, v_off_fin = 664.612 uV 20:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.957 uVs 20:24:22 Integrated Voltage Measurement... 20:24:31 Voltage Offset Correction: v_off_ini = 668.882 uV, v_off_fin = 671.502 uV 20:24:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.897 uVs 20:24:31 Integrated Voltage Measurement... 20:24:40 Voltage Offset Correction: v_off_ini = 676.217 uV, v_off_fin = 673.443 uV 20:24:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.766 uVs 20:24:40 Integrated Voltage Measurement... 20:24:49 Voltage Offset Correction: v_off_ini = 662.089 uV, v_off_fin = 678.830 uV 20:24:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.575 uVs 20:24:53 I1Y Average and RMS of Measurements VT = -194.440 +- 2.399 uVs I1Y = -38.885 +- 0.479 uTm 20:24:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:24:58 Integrated Voltage Measurement... 20:25:07 Voltage Offset Correction: v_off_ini = 660.259 uV, v_off_fin = 652.115 uV 20:25:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.119 uVs 20:25:07 Integrated Voltage Measurement... 20:25:16 Voltage Offset Correction: v_off_ini = 673.600 uV, v_off_fin = 674.521 uV 20:25:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 46.487 uVs 20:25:16 Integrated Voltage Measurement... 20:25:25 Voltage Offset Correction: v_off_ini = 670.985 uV, v_off_fin = 661.371 uV 20:25:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.517 uVs 20:25:25 Integrated Voltage Measurement... 20:25:34 Voltage Offset Correction: v_off_ini = 670.166 uV, v_off_fin = 673.147 uV 20:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.287 uVs 20:25:34 Integrated Voltage Measurement... 20:25:43 Voltage Offset Correction: v_off_ini = 665.715 uV, v_off_fin = 673.311 uV 20:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.741 uVs 20:25:43 Integrated Voltage Measurement... 20:25:52 Voltage Offset Correction: v_off_ini = 673.896 uV, v_off_fin = 675.789 uV 20:25:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.972 uVs 20:25:55 I2X Average and RMS of Measurements VT = -58.687 +- 6.750 uVs I2X = 5.399 +- 0.621 uTm^2 20:25:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:26:00 Integrated Voltage Measurement... 20:26:09 Voltage Offset Correction: v_off_ini = 669.102 uV, v_off_fin = 666.927 uV 20:26:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.016 uVs 20:26:09 Integrated Voltage Measurement... 20:26:18 Voltage Offset Correction: v_off_ini = 672.557 uV, v_off_fin = 672.755 uV 20:26:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.676 uVs 20:26:18 Integrated Voltage Measurement... 20:26:27 Voltage Offset Correction: v_off_ini = 671.943 uV, v_off_fin = 670.897 uV 20:26:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.524 uVs 20:26:27 Integrated Voltage Measurement... 20:26:36 Voltage Offset Correction: v_off_ini = 672.607 uV, v_off_fin = 670.340 uV 20:26:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.065 uVs 20:26:36 Integrated Voltage Measurement... 20:26:45 Voltage Offset Correction: v_off_ini = 673.391 uV, v_off_fin = 660.971 uV 20:26:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -453.477 uVs 20:26:45 Integrated Voltage Measurement... 20:26:54 Voltage Offset Correction: v_off_ini = 666.085 uV, v_off_fin = 682.909 uV 20:26:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.224 uVs 20:26:56 I2Y Average and RMS of Measurements VT = -469.497 +- 3.276 uVs I2Y = -43.194 +- 0.301 uTm^2 20:27:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:27:18 Integrated Voltage Measurement... 20:27:27 Voltage Offset Correction: v_off_ini = 668.853 uV, v_off_fin = 681.229 uV 20:27:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.518 uVs 20:27:27 Integrated Voltage Measurement... 20:27:36 Voltage Offset Correction: v_off_ini = 675.004 uV, v_off_fin = 699.401 uV 20:27:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.517 uVs 20:27:36 Integrated Voltage Measurement... 20:27:45 Voltage Offset Correction: v_off_ini = 701.232 uV, v_off_fin = 688.246 uV 20:27:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.910 uVs 20:27:45 Integrated Voltage Measurement... 20:27:54 Voltage Offset Correction: v_off_ini = 702.565 uV, v_off_fin = 691.570 uV 20:27:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.171 uVs 20:27:54 Integrated Voltage Measurement... 20:28:03 Voltage Offset Correction: v_off_ini = 693.725 uV, v_off_fin = 702.933 uV 20:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.884 uVs 20:28:03 Integrated Voltage Measurement... 20:28:12 Voltage Offset Correction: v_off_ini = 699.157 uV, v_off_fin = 688.257 uV 20:28:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.507 uVs 20:28:16 I1X Average and RMS of Measurements VT = -95.918 +- 1.030 uVs I1X = 19.184 +- 0.206 uTm 20:28:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:28:23 Integrated Voltage Measurement... 20:28:32 Voltage Offset Correction: v_off_ini = 696.207 uV, v_off_fin = 688.140 uV 20:28:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.628 uVs 20:28:32 Integrated Voltage Measurement... 20:28:41 Voltage Offset Correction: v_off_ini = 697.157 uV, v_off_fin = 704.990 uV 20:28:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.898 uVs 20:28:41 Integrated Voltage Measurement... 20:28:50 Voltage Offset Correction: v_off_ini = 694.102 uV, v_off_fin = 673.740 uV 20:28:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.578 uVs 20:28:50 Integrated Voltage Measurement... 20:28:59 Voltage Offset Correction: v_off_ini = 686.185 uV, v_off_fin = 694.209 uV 20:28:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.588 uVs 20:28:59 Integrated Voltage Measurement... 20:29:08 Voltage Offset Correction: v_off_ini = 691.146 uV, v_off_fin = 662.196 uV 20:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.722 uVs 20:29:08 Integrated Voltage Measurement... 20:29:17 Voltage Offset Correction: v_off_ini = 669.670 uV, v_off_fin = 687.056 uV 20:29:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.079 uVs 20:29:21 I1Y Average and RMS of Measurements VT = -197.915 +- 6.388 uVs I1Y = -39.583 +- 1.278 uTm 20:29:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:29:29 Integrated Voltage Measurement... 20:29:38 Voltage Offset Correction: v_off_ini = 678.545 uV, v_off_fin = 667.184 uV 20:29:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.308 uVs 20:29:38 Integrated Voltage Measurement... 20:29:47 Voltage Offset Correction: v_off_ini = 675.200 uV, v_off_fin = 664.907 uV 20:29:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.310 uVs 20:29:47 Integrated Voltage Measurement... 20:29:56 Voltage Offset Correction: v_off_ini = 681.780 uV, v_off_fin = 656.723 uV 20:29:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.719 uVs 20:29:56 Integrated Voltage Measurement... 20:30:05 Voltage Offset Correction: v_off_ini = 674.158 uV, v_off_fin = 667.672 uV 20:30:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.255 uVs 20:30:05 Integrated Voltage Measurement... 20:30:14 Voltage Offset Correction: v_off_ini = 670.964 uV, v_off_fin = 661.384 uV 20:30:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.566 uVs 20:30:14 Integrated Voltage Measurement... 20:30:23 Voltage Offset Correction: v_off_ini = 672.746 uV, v_off_fin = 681.628 uV 20:30:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.446 uVs 20:30:25 I2X Average and RMS of Measurements VT = -83.934 +- 6.420 uVs I2X = 7.722 +- 0.591 uTm^2 20:30:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:30:33 Integrated Voltage Measurement... 20:30:42 Voltage Offset Correction: v_off_ini = 668.619 uV, v_off_fin = 674.478 uV 20:30:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.977 uVs 20:30:42 Integrated Voltage Measurement... 20:30:51 Voltage Offset Correction: v_off_ini = 668.673 uV, v_off_fin = 680.621 uV 20:30:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 453.345 uVs 20:30:51 Integrated Voltage Measurement... 20:31:00 Voltage Offset Correction: v_off_ini = 670.923 uV, v_off_fin = 677.696 uV 20:31:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -453.892 uVs 20:31:00 Integrated Voltage Measurement... 20:31:09 Voltage Offset Correction: v_off_ini = 679.254 uV, v_off_fin = 677.768 uV 20:31:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.085 uVs 20:31:09 Integrated Voltage Measurement... 20:31:18 Voltage Offset Correction: v_off_ini = 669.682 uV, v_off_fin = 668.735 uV 20:31:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -441.576 uVs 20:31:18 Integrated Voltage Measurement... 20:31:27 Voltage Offset Correction: v_off_ini = 667.431 uV, v_off_fin = 655.632 uV 20:31:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.903 uVs 20:31:30 I2Y Average and RMS of Measurements VT = -453.796 +- 1.767 uVs I2Y = -41.749 +- 0.163 uTm^2 20:31:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:31:39 Integrated Voltage Measurement... 20:31:48 Voltage Offset Correction: v_off_ini = 673.299 uV, v_off_fin = 672.229 uV 20:31:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.942 uVs 20:31:48 Integrated Voltage Measurement... 20:31:57 Voltage Offset Correction: v_off_ini = 670.043 uV, v_off_fin = 664.605 uV 20:31:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.275 uVs 20:31:57 Integrated Voltage Measurement... 20:32:06 Voltage Offset Correction: v_off_ini = 664.222 uV, v_off_fin = 669.967 uV 20:32:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.961 uVs 20:32:06 Integrated Voltage Measurement... 20:32:15 Voltage Offset Correction: v_off_ini = 667.023 uV, v_off_fin = 660.935 uV 20:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.931 uVs 20:32:15 Integrated Voltage Measurement... 20:32:24 Voltage Offset Correction: v_off_ini = 655.570 uV, v_off_fin = 662.382 uV 20:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.511 uVs 20:32:24 Integrated Voltage Measurement... 20:32:33 Voltage Offset Correction: v_off_ini = 668.732 uV, v_off_fin = 678.164 uV 20:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.431 uVs 20:32:37 I1X Average and RMS of Measurements VT = -93.675 +- 4.412 uVs I1X = 18.735 +- 0.882 uTm 20:32:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:32:44 Integrated Voltage Measurement... 20:32:53 Voltage Offset Correction: v_off_ini = 674.108 uV, v_off_fin = 670.916 uV 20:32:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.528 uVs 20:32:53 Integrated Voltage Measurement... 20:33:02 Voltage Offset Correction: v_off_ini = 673.809 uV, v_off_fin = 689.350 uV 20:33:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.875 uVs 20:33:02 Integrated Voltage Measurement... 20:33:11 Voltage Offset Correction: v_off_ini = 674.334 uV, v_off_fin = 671.157 uV 20:33:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.705 uVs 20:33:11 Integrated Voltage Measurement... 20:33:20 Voltage Offset Correction: v_off_ini = 676.445 uV, v_off_fin = 683.176 uV 20:33:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.015 uVs 20:33:20 Integrated Voltage Measurement... 20:33:29 Voltage Offset Correction: v_off_ini = 671.436 uV, v_off_fin = 656.847 uV 20:33:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.289 uVs 20:33:29 Integrated Voltage Measurement... 20:33:38 Voltage Offset Correction: v_off_ini = 657.344 uV, v_off_fin = 670.535 uV 20:33:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.422 uVs 20:33:42 I1Y Average and RMS of Measurements VT = -200.306 +- 1.152 uVs I1Y = -40.061 +- 0.230 uTm 20:33:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:33:50 Integrated Voltage Measurement... 20:33:59 Voltage Offset Correction: v_off_ini = 655.250 uV, v_off_fin = 649.399 uV 20:33:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.411 uVs 20:33:59 Integrated Voltage Measurement... 20:34:08 Voltage Offset Correction: v_off_ini = 656.115 uV, v_off_fin = 662.209 uV 20:34:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.440 uVs 20:34:08 Integrated Voltage Measurement... 20:34:17 Voltage Offset Correction: v_off_ini = 649.377 uV, v_off_fin = 646.561 uV 20:34:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.626 uVs 20:34:17 Integrated Voltage Measurement... 20:34:26 Voltage Offset Correction: v_off_ini = 665.828 uV, v_off_fin = 665.146 uV 20:34:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.123 uVs 20:34:26 Integrated Voltage Measurement... 20:34:35 Voltage Offset Correction: v_off_ini = 661.201 uV, v_off_fin = 645.215 uV 20:34:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.885 uVs 20:34:35 Integrated Voltage Measurement... 20:34:44 Voltage Offset Correction: v_off_ini = 649.170 uV, v_off_fin = 663.582 uV 20:34:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.641 uVs 20:34:47 I2X Average and RMS of Measurements VT = -83.188 +- 8.783 uVs I2X = 7.653 +- 0.808 uTm^2 20:34:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:34:54 Integrated Voltage Measurement... 20:35:03 Voltage Offset Correction: v_off_ini = 656.671 uV, v_off_fin = 655.416 uV 20:35:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.817 uVs 20:35:03 Integrated Voltage Measurement... 20:35:12 Voltage Offset Correction: v_off_ini = 656.423 uV, v_off_fin = 653.305 uV 20:35:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 452.823 uVs 20:35:12 Integrated Voltage Measurement... 20:35:21 Voltage Offset Correction: v_off_ini = 666.067 uV, v_off_fin = 661.995 uV 20:35:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.600 uVs 20:35:21 Integrated Voltage Measurement... 20:35:30 Voltage Offset Correction: v_off_ini = 645.550 uV, v_off_fin = 652.391 uV 20:35:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 471.850 uVs 20:35:30 Integrated Voltage Measurement... 20:35:39 Voltage Offset Correction: v_off_ini = 645.310 uV, v_off_fin = 651.466 uV 20:35:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.807 uVs 20:35:40 Integrated Voltage Measurement... 20:35:48 Voltage Offset Correction: v_off_ini = 635.280 uV, v_off_fin = 642.977 uV 20:35:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.631 uVs 20:35:51 I2Y Average and RMS of Measurements VT = -459.921 +- 2.140 uVs I2Y = -42.313 +- 0.197 uTm^2 20:35:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:36:00 Integrated Voltage Measurement... 20:36:09 Voltage Offset Correction: v_off_ini = 650.072 uV, v_off_fin = 663.101 uV 20:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.386 uVs 20:36:09 Integrated Voltage Measurement... 20:36:18 Voltage Offset Correction: v_off_ini = 651.446 uV, v_off_fin = 652.768 uV 20:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.663 uVs 20:36:18 Integrated Voltage Measurement... 20:36:27 Voltage Offset Correction: v_off_ini = 644.762 uV, v_off_fin = 638.716 uV 20:36:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -94.375 uVs 20:36:27 Integrated Voltage Measurement... 20:36:36 Voltage Offset Correction: v_off_ini = 655.097 uV, v_off_fin = 655.419 uV 20:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 106.014 uVs 20:36:36 Integrated Voltage Measurement... 20:36:45 Voltage Offset Correction: v_off_ini = 656.432 uV, v_off_fin = 642.435 uV 20:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.386 uVs 20:36:45 Integrated Voltage Measurement... 20:36:54 Voltage Offset Correction: v_off_ini = 644.439 uV, v_off_fin = 643.675 uV 20:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.900 uVs 20:36:58 I1X Average and RMS of Measurements VT = -98.621 +- 4.081 uVs I1X = 19.725 +- 0.817 uTm 20:37:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:37:05 Integrated Voltage Measurement... 20:37:14 Voltage Offset Correction: v_off_ini = 629.486 uV, v_off_fin = 615.946 uV 20:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.414 uVs 20:37:14 Integrated Voltage Measurement... 20:37:23 Voltage Offset Correction: v_off_ini = 634.238 uV, v_off_fin = 643.524 uV 20:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.538 uVs 20:37:23 Integrated Voltage Measurement... 20:37:32 Voltage Offset Correction: v_off_ini = 641.560 uV, v_off_fin = 627.662 uV 20:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.863 uVs 20:37:32 Integrated Voltage Measurement... 20:37:41 Voltage Offset Correction: v_off_ini = 641.630 uV, v_off_fin = 641.275 uV 20:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.263 uVs 20:37:41 Integrated Voltage Measurement... 20:37:50 Voltage Offset Correction: v_off_ini = 638.984 uV, v_off_fin = 638.355 uV 20:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.559 uVs 20:37:50 Integrated Voltage Measurement... 20:37:59 Voltage Offset Correction: v_off_ini = 635.983 uV, v_off_fin = 640.628 uV 20:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.148 uVs 20:38:03 I1Y Average and RMS of Measurements VT = -200.298 +- 6.906 uVs I1Y = -40.060 +- 1.381 uTm 20:38:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:38:11 Integrated Voltage Measurement... 20:38:20 Voltage Offset Correction: v_off_ini = 637.667 uV, v_off_fin = 636.000 uV 20:38:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.593 uVs 20:38:20 Integrated Voltage Measurement... 20:38:29 Voltage Offset Correction: v_off_ini = 648.455 uV, v_off_fin = 648.554 uV 20:38:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.212 uVs 20:38:29 Integrated Voltage Measurement... 20:38:38 Voltage Offset Correction: v_off_ini = 656.724 uV, v_off_fin = 643.552 uV 20:38:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.059 uVs 20:38:38 Integrated Voltage Measurement... 20:38:47 Voltage Offset Correction: v_off_ini = 656.983 uV, v_off_fin = 658.271 uV 20:38:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.599 uVs 20:38:47 Integrated Voltage Measurement... 20:38:56 Voltage Offset Correction: v_off_ini = 665.373 uV, v_off_fin = 649.702 uV 20:38:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.972 uVs 20:38:56 Integrated Voltage Measurement... 20:39:05 Voltage Offset Correction: v_off_ini = 661.229 uV, v_off_fin = 659.199 uV 20:39:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.957 uVs 20:39:08 I2X Average and RMS of Measurements VT = -84.898 +- 2.067 uVs I2X = 7.811 +- 0.190 uTm^2 20:39:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:39:15 Integrated Voltage Measurement... 20:39:24 Voltage Offset Correction: v_off_ini = 674.027 uV, v_off_fin = 667.629 uV 20:39:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -468.032 uVs 20:39:24 Integrated Voltage Measurement... 20:39:33 Voltage Offset Correction: v_off_ini = 667.735 uV, v_off_fin = 668.499 uV 20:39:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 470.334 uVs 20:39:33 Integrated Voltage Measurement... 20:39:42 Voltage Offset Correction: v_off_ini = 672.318 uV, v_off_fin = 671.127 uV 20:39:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.398 uVs 20:39:42 Integrated Voltage Measurement... 20:39:51 Voltage Offset Correction: v_off_ini = 670.059 uV, v_off_fin = 666.729 uV 20:39:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.018 uVs 20:39:52 Integrated Voltage Measurement... 20:40:01 Voltage Offset Correction: v_off_ini = 669.965 uV, v_off_fin = 669.000 uV 20:40:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -464.499 uVs 20:40:01 Integrated Voltage Measurement... 20:40:10 Voltage Offset Correction: v_off_ini = 679.004 uV, v_off_fin = 679.227 uV 20:40:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.304 uVs 20:40:12 I2Y Average and RMS of Measurements VT = -466.598 +- 3.120 uVs I2Y = -42.927 +- 0.287 uTm^2 20:40:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:40:21 Integrated Voltage Measurement... 20:40:30 Voltage Offset Correction: v_off_ini = 672.630 uV, v_off_fin = 673.800 uV 20:40:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -110.703 uVs 20:40:30 Integrated Voltage Measurement... 20:40:39 Voltage Offset Correction: v_off_ini = 675.371 uV, v_off_fin = 683.806 uV 20:40:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.992 uVs 20:40:39 Integrated Voltage Measurement... 20:40:48 Voltage Offset Correction: v_off_ini = 680.203 uV, v_off_fin = 689.370 uV 20:40:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.016 uVs 20:40:48 Integrated Voltage Measurement... 20:40:57 Voltage Offset Correction: v_off_ini = 687.434 uV, v_off_fin = 697.514 uV 20:40:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.575 uVs 20:40:57 Integrated Voltage Measurement... 20:41:06 Voltage Offset Correction: v_off_ini = 691.314 uV, v_off_fin = 672.352 uV 20:41:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.678 uVs 20:41:06 Integrated Voltage Measurement... 20:41:15 Voltage Offset Correction: v_off_ini = 683.625 uV, v_off_fin = 693.456 uV 20:41:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 91.136 uVs 20:41:19 I1X Average and RMS of Measurements VT = -97.350 +- 5.225 uVs I1X = 19.472 +- 1.046 uTm 20:41:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:41:26 Integrated Voltage Measurement... 20:41:35 Voltage Offset Correction: v_off_ini = 685.086 uV, v_off_fin = 669.487 uV 20:41:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -208.753 uVs 20:41:35 Integrated Voltage Measurement... 20:41:44 Voltage Offset Correction: v_off_ini = 682.773 uV, v_off_fin = 692.921 uV 20:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.305 uVs 20:41:44 Integrated Voltage Measurement... 20:41:53 Voltage Offset Correction: v_off_ini = 691.485 uV, v_off_fin = 683.241 uV 20:41:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.822 uVs 20:41:53 Integrated Voltage Measurement... 20:42:02 Voltage Offset Correction: v_off_ini = 690.985 uV, v_off_fin = 700.011 uV 20:42:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.551 uVs 20:42:02 Integrated Voltage Measurement... 20:42:11 Voltage Offset Correction: v_off_ini = 688.611 uV, v_off_fin = 690.288 uV 20:42:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.728 uVs 20:42:11 Integrated Voltage Measurement... 20:42:20 Voltage Offset Correction: v_off_ini = 696.503 uV, v_off_fin = 700.593 uV 20:42:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.957 uVs 20:42:24 I1Y Average and RMS of Measurements VT = -202.519 +- 4.641 uVs I1Y = -40.505 +- 0.928 uTm 20:42:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:42:32 Integrated Voltage Measurement... 20:42:41 Voltage Offset Correction: v_off_ini = 684.839 uV, v_off_fin = 690.795 uV 20:42:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.293 uVs 20:42:41 Integrated Voltage Measurement... 20:42:50 Voltage Offset Correction: v_off_ini = 705.648 uV, v_off_fin = 702.213 uV 20:42:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.756 uVs 20:42:50 Integrated Voltage Measurement... 20:42:59 Voltage Offset Correction: v_off_ini = 698.930 uV, v_off_fin = 680.987 uV 20:42:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.220 uVs 20:42:59 Integrated Voltage Measurement... 20:43:08 Voltage Offset Correction: v_off_ini = 694.894 uV, v_off_fin = 692.595 uV 20:43:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.050 uVs 20:43:08 Integrated Voltage Measurement... 20:43:17 Voltage Offset Correction: v_off_ini = 697.179 uV, v_off_fin = 683.069 uV 20:43:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.010 uVs 20:43:17 Integrated Voltage Measurement... 20:43:26 Voltage Offset Correction: v_off_ini = 695.565 uV, v_off_fin = 700.657 uV 20:43:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.611 uVs 20:43:28 I2X Average and RMS of Measurements VT = -77.157 +- 2.509 uVs I2X = 7.099 +- 0.231 uTm^2 20:43:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:43:36 Integrated Voltage Measurement... 20:43:45 Voltage Offset Correction: v_off_ini = 704.737 uV, v_off_fin = 699.957 uV 20:43:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.177 uVs 20:43:45 Integrated Voltage Measurement... 20:43:54 Voltage Offset Correction: v_off_ini = 686.201 uV, v_off_fin = 689.382 uV 20:43:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.023 uVs 20:43:54 Integrated Voltage Measurement... 20:44:03 Voltage Offset Correction: v_off_ini = 684.940 uV, v_off_fin = 678.423 uV 20:44:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.974 uVs 20:44:03 Integrated Voltage Measurement... 20:44:12 Voltage Offset Correction: v_off_ini = 688.192 uV, v_off_fin = 681.317 uV 20:44:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 475.644 uVs 20:44:12 Integrated Voltage Measurement... 20:44:21 Voltage Offset Correction: v_off_ini = 695.958 uV, v_off_fin = 695.894 uV 20:44:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.345 uVs 20:44:21 Integrated Voltage Measurement... 20:44:30 Voltage Offset Correction: v_off_ini = 688.035 uV, v_off_fin = 690.156 uV 20:44:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.138 uVs 20:44:33 I2Y Average and RMS of Measurements VT = -465.383 +- 5.326 uVs I2Y = -42.815 +- 0.490 uTm^2 20:44:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:44:42 Integrated Voltage Measurement... 20:44:51 Voltage Offset Correction: v_off_ini = 688.367 uV, v_off_fin = 680.489 uV 20:44:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.243 uVs 20:44:51 Integrated Voltage Measurement... 20:45:00 Voltage Offset Correction: v_off_ini = 685.653 uV, v_off_fin = 684.983 uV 20:45:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.299 uVs 20:45:00 Integrated Voltage Measurement... 20:45:09 Voltage Offset Correction: v_off_ini = 680.079 uV, v_off_fin = 678.507 uV 20:45:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.577 uVs 20:45:09 Integrated Voltage Measurement... 20:45:18 Voltage Offset Correction: v_off_ini = 683.252 uV, v_off_fin = 684.407 uV 20:45:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.287 uVs 20:45:18 Integrated Voltage Measurement... 20:45:27 Voltage Offset Correction: v_off_ini = 686.131 uV, v_off_fin = 678.273 uV 20:45:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.562 uVs 20:45:27 Integrated Voltage Measurement... 20:45:36 Voltage Offset Correction: v_off_ini = 684.597 uV, v_off_fin = 688.309 uV 20:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 115.290 uVs 20:45:40 I1X Average and RMS of Measurements VT = -92.210 +- 13.122 uVs I1X = 18.443 +- 2.625 uTm 20:45:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:45:47 Integrated Voltage Measurement... 20:45:56 Voltage Offset Correction: v_off_ini = 680.190 uV, v_off_fin = 667.204 uV 20:45:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.479 uVs 20:45:56 Integrated Voltage Measurement... 20:46:04 Voltage Offset Correction: v_off_ini = 691.714 uV, v_off_fin = 695.181 uV 20:46:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.486 uVs 20:46:05 Integrated Voltage Measurement... 20:46:13 Voltage Offset Correction: v_off_ini = 685.438 uV, v_off_fin = 670.328 uV 20:46:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.380 uVs 20:46:14 Integrated Voltage Measurement... 20:46:22 Voltage Offset Correction: v_off_ini = 667.469 uV, v_off_fin = 686.523 uV 20:46:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.101 uVs 20:46:23 Integrated Voltage Measurement... 20:46:31 Voltage Offset Correction: v_off_ini = 685.929 uV, v_off_fin = 676.655 uV 20:46:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.177 uVs 20:46:32 Integrated Voltage Measurement... 20:46:40 Voltage Offset Correction: v_off_ini = 683.316 uV, v_off_fin = 681.715 uV 20:46:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.049 uVs 20:46:45 I1Y Average and RMS of Measurements VT = -196.279 +- 6.741 uVs I1Y = -39.256 +- 1.348 uTm 20:46:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:46:52 Integrated Voltage Measurement... 20:47:01 Voltage Offset Correction: v_off_ini = 676.078 uV, v_off_fin = 674.337 uV 20:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.555 uVs 20:47:01 Integrated Voltage Measurement... 20:47:10 Voltage Offset Correction: v_off_ini = 679.401 uV, v_off_fin = 683.657 uV 20:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.084 uVs 20:47:10 Integrated Voltage Measurement... 20:47:19 Voltage Offset Correction: v_off_ini = 679.972 uV, v_off_fin = 662.492 uV 20:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.839 uVs 20:47:19 Integrated Voltage Measurement... 20:47:28 Voltage Offset Correction: v_off_ini = 673.639 uV, v_off_fin = 691.081 uV 20:47:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.785 uVs 20:47:29 Integrated Voltage Measurement... 20:47:37 Voltage Offset Correction: v_off_ini = 691.234 uV, v_off_fin = 684.233 uV 20:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.896 uVs 20:47:38 Integrated Voltage Measurement... 20:47:47 Voltage Offset Correction: v_off_ini = 686.895 uV, v_off_fin = 687.328 uV 20:47:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.661 uVs 20:47:49 I2X Average and RMS of Measurements VT = -89.637 +- 4.247 uVs I2X = 8.247 +- 0.391 uTm^2 20:47:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:47:57 Integrated Voltage Measurement... 20:48:06 Voltage Offset Correction: v_off_ini = 694.541 uV, v_off_fin = 686.310 uV 20:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.701 uVs 20:48:06 Integrated Voltage Measurement... 20:48:15 Voltage Offset Correction: v_off_ini = 697.949 uV, v_off_fin = 688.180 uV 20:48:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.507 uVs 20:48:15 Integrated Voltage Measurement... 20:48:24 Voltage Offset Correction: v_off_ini = 683.878 uV, v_off_fin = 683.930 uV 20:48:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -470.560 uVs 20:48:24 Integrated Voltage Measurement... 20:48:33 Voltage Offset Correction: v_off_ini = 665.459 uV, v_off_fin = 677.879 uV 20:48:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.278 uVs 20:48:33 Integrated Voltage Measurement... 20:48:42 Voltage Offset Correction: v_off_ini = 679.519 uV, v_off_fin = 690.835 uV 20:48:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.223 uVs 20:48:42 Integrated Voltage Measurement... 20:48:51 Voltage Offset Correction: v_off_ini = 674.783 uV, v_off_fin = 680.209 uV 20:48:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.804 uVs 20:48:53 I2Y Average and RMS of Measurements VT = -460.846 +- 2.989 uVs I2Y = -42.399 +- 0.276 uTm^2 20:49:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:49:05 Integrated Voltage Measurement... 20:49:14 Voltage Offset Correction: v_off_ini = 676.603 uV, v_off_fin = 662.964 uV 20:49:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.267 uVs 20:49:14 Integrated Voltage Measurement... 20:49:23 Voltage Offset Correction: v_off_ini = 671.373 uV, v_off_fin = 665.931 uV 20:49:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.852 uVs 20:49:23 Integrated Voltage Measurement... 20:49:32 Voltage Offset Correction: v_off_ini = 668.649 uV, v_off_fin = 661.035 uV 20:49:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.336 uVs 20:49:32 Integrated Voltage Measurement... 20:49:41 Voltage Offset Correction: v_off_ini = 677.522 uV, v_off_fin = 659.461 uV 20:49:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.398 uVs 20:49:41 Integrated Voltage Measurement... 20:49:50 Voltage Offset Correction: v_off_ini = 657.605 uV, v_off_fin = 660.647 uV 20:49:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.487 uVs 20:49:50 Integrated Voltage Measurement... 20:49:59 Voltage Offset Correction: v_off_ini = 652.810 uV, v_off_fin = 666.649 uV 20:49:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.050 uVs 20:50:03 I1X Average and RMS of Measurements VT = -83.565 +- 2.005 uVs I1X = 16.713 +- 0.401 uTm 20:50:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:50:10 Integrated Voltage Measurement... 20:50:19 Voltage Offset Correction: v_off_ini = 673.990 uV, v_off_fin = 668.270 uV 20:50:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.045 uVs 20:50:19 Integrated Voltage Measurement... 20:50:28 Voltage Offset Correction: v_off_ini = 661.671 uV, v_off_fin = 667.957 uV 20:50:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.834 uVs 20:50:28 Integrated Voltage Measurement... 20:50:37 Voltage Offset Correction: v_off_ini = 668.884 uV, v_off_fin = 659.161 uV 20:50:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.985 uVs 20:50:37 Integrated Voltage Measurement... 20:50:46 Voltage Offset Correction: v_off_ini = 670.867 uV, v_off_fin = 676.185 uV 20:50:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.749 uVs 20:50:46 Integrated Voltage Measurement... 20:50:55 Voltage Offset Correction: v_off_ini = 674.767 uV, v_off_fin = 668.444 uV 20:50:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.685 uVs 20:50:55 Integrated Voltage Measurement... 20:51:04 Voltage Offset Correction: v_off_ini = 677.122 uV, v_off_fin = 690.378 uV 20:51:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.311 uVs 20:51:08 I1Y Average and RMS of Measurements VT = -197.602 +- 4.134 uVs I1Y = -39.520 +- 0.827 uTm 20:51:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:51:14 Integrated Voltage Measurement... 20:51:22 Voltage Offset Correction: v_off_ini = 676.722 uV, v_off_fin = 684.852 uV 20:51:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.654 uVs 20:51:23 Integrated Voltage Measurement... 20:51:32 Voltage Offset Correction: v_off_ini = 692.337 uV, v_off_fin = 706.079 uV 20:51:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.672 uVs 20:51:32 Integrated Voltage Measurement... 20:51:41 Voltage Offset Correction: v_off_ini = 678.866 uV, v_off_fin = 680.886 uV 20:51:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.227 uVs 20:51:41 Integrated Voltage Measurement... 20:51:50 Voltage Offset Correction: v_off_ini = 697.281 uV, v_off_fin = 703.880 uV 20:51:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.666 uVs 20:51:50 Integrated Voltage Measurement... 20:51:59 Voltage Offset Correction: v_off_ini = 690.387 uV, v_off_fin = 674.104 uV 20:51:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.550 uVs 20:51:59 Integrated Voltage Measurement... 20:52:08 Voltage Offset Correction: v_off_ini = 686.148 uV, v_off_fin = 692.221 uV 20:52:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.910 uVs 20:52:10 I2X Average and RMS of Measurements VT = -68.947 +- 2.297 uVs I2X = 6.343 +- 0.211 uTm^2 20:52:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:52:15 Integrated Voltage Measurement... 20:52:24 Voltage Offset Correction: v_off_ini = 694.886 uV, v_off_fin = 691.686 uV 20:52:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -466.385 uVs 20:52:24 Integrated Voltage Measurement... 20:52:33 Voltage Offset Correction: v_off_ini = 690.082 uV, v_off_fin = 702.520 uV 20:52:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 452.676 uVs 20:52:33 Integrated Voltage Measurement... 20:52:42 Voltage Offset Correction: v_off_ini = 695.337 uV, v_off_fin = 691.381 uV 20:52:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -443.596 uVs 20:52:42 Integrated Voltage Measurement... 20:52:51 Voltage Offset Correction: v_off_ini = 673.343 uV, v_off_fin = 687.657 uV 20:52:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.608 uVs 20:52:51 Integrated Voltage Measurement... 20:53:00 Voltage Offset Correction: v_off_ini = 680.742 uV, v_off_fin = 678.051 uV 20:53:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.773 uVs 20:53:00 Integrated Voltage Measurement... 20:53:09 Voltage Offset Correction: v_off_ini = 683.628 uV, v_off_fin = 688.585 uV 20:53:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.481 uVs 20:53:12 I2Y Average and RMS of Measurements VT = -461.087 +- 6.031 uVs I2Y = -42.421 +- 0.554 uTm^2 20:53:16 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:53:20 Integrated Voltage Measurement... 20:53:29 Voltage Offset Correction: v_off_ini = 690.268 uV, v_off_fin = 688.120 uV 20:53:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.458 uVs 20:53:29 Integrated Voltage Measurement... 20:53:38 Voltage Offset Correction: v_off_ini = 693.564 uV, v_off_fin = 689.697 uV 20:53:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.380 uVs 20:53:38 Integrated Voltage Measurement... 20:53:47 Voltage Offset Correction: v_off_ini = 687.441 uV, v_off_fin = 695.510 uV 20:53:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.435 uVs 20:53:47 Integrated Voltage Measurement... 20:53:56 Voltage Offset Correction: v_off_ini = 693.997 uV, v_off_fin = 695.337 uV 20:53:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.537 uVs 20:53:56 Integrated Voltage Measurement... 20:54:05 Voltage Offset Correction: v_off_ini = 692.085 uV, v_off_fin = 685.579 uV 20:54:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.177 uVs 20:54:05 Integrated Voltage Measurement... 20:54:14 Voltage Offset Correction: v_off_ini = 687.450 uV, v_off_fin = 698.312 uV 20:54:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 100.065 uVs 20:54:18 I1X Average and RMS of Measurements VT = -95.009 +- 3.503 uVs I1X = 19.002 +- 0.700 uTm 20:54:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:54:25 Integrated Voltage Measurement... 20:54:34 Voltage Offset Correction: v_off_ini = 688.569 uV, v_off_fin = 676.277 uV 20:54:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.534 uVs 20:54:34 Integrated Voltage Measurement... 20:54:43 Voltage Offset Correction: v_off_ini = 676.588 uV, v_off_fin = 699.488 uV 20:54:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.695 uVs 20:54:43 Integrated Voltage Measurement... 20:54:52 Voltage Offset Correction: v_off_ini = 681.837 uV, v_off_fin = 681.760 uV 20:54:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.862 uVs 20:54:52 Integrated Voltage Measurement... 20:55:01 Voltage Offset Correction: v_off_ini = 685.593 uV, v_off_fin = 680.995 uV 20:55:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.373 uVs 20:55:01 Integrated Voltage Measurement... 20:55:10 Voltage Offset Correction: v_off_ini = 678.808 uV, v_off_fin = 663.327 uV 20:55:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.832 uVs 20:55:10 Integrated Voltage Measurement... 20:55:19 Voltage Offset Correction: v_off_ini = 677.146 uV, v_off_fin = 683.975 uV 20:55:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.348 uVs 20:55:23 I1Y Average and RMS of Measurements VT = -197.774 +- 9.665 uVs I1Y = -39.555 +- 1.933 uTm 20:55:26 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:55:28 Integrated Voltage Measurement... 20:55:37 Voltage Offset Correction: v_off_ini = 680.718 uV, v_off_fin = 674.930 uV 20:55:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.262 uVs 20:55:37 Integrated Voltage Measurement... 20:55:46 Voltage Offset Correction: v_off_ini = 681.051 uV, v_off_fin = 689.815 uV 20:55:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.733 uVs 20:55:46 Integrated Voltage Measurement... 20:55:55 Voltage Offset Correction: v_off_ini = 679.308 uV, v_off_fin = 670.573 uV 20:55:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.691 uVs 20:55:55 Integrated Voltage Measurement... 20:56:04 Voltage Offset Correction: v_off_ini = 681.737 uV, v_off_fin = 685.558 uV 20:56:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.802 uVs 20:56:04 Integrated Voltage Measurement... 20:56:13 Voltage Offset Correction: v_off_ini = 688.222 uV, v_off_fin = 674.130 uV 20:56:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.025 uVs 20:56:13 Integrated Voltage Measurement... 20:56:22 Voltage Offset Correction: v_off_ini = 680.025 uV, v_off_fin = 684.778 uV 20:56:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.991 uVs 20:56:25 I2X Average and RMS of Measurements VT = -85.751 +- 4.289 uVs I2X = 7.889 +- 0.395 uTm^2 20:56:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:56:30 Integrated Voltage Measurement... 20:56:39 Voltage Offset Correction: v_off_ini = 673.382 uV, v_off_fin = 687.631 uV 20:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.372 uVs 20:56:39 Integrated Voltage Measurement... 20:56:48 Voltage Offset Correction: v_off_ini = 688.537 uV, v_off_fin = 689.361 uV 20:56:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.488 uVs 20:56:48 Integrated Voltage Measurement... 20:56:57 Voltage Offset Correction: v_off_ini = 692.141 uV, v_off_fin = 692.014 uV 20:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.899 uVs 20:56:57 Integrated Voltage Measurement... 20:57:06 Voltage Offset Correction: v_off_ini = 699.874 uV, v_off_fin = 695.922 uV 20:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.432 uVs 20:57:06 Integrated Voltage Measurement... 20:57:15 Voltage Offset Correction: v_off_ini = 690.890 uV, v_off_fin = 685.269 uV 20:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.502 uVs 20:57:15 Integrated Voltage Measurement... 20:57:24 Voltage Offset Correction: v_off_ini = 689.497 uV, v_off_fin = 684.279 uV 20:57:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 461.528 uVs 20:57:27 I2Y Average and RMS of Measurements VT = -452.370 +- 7.912 uVs I2Y = -41.618 +- 0.728 uTm^2 20:57:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:57:35 Integrated Voltage Measurement... 20:57:44 Voltage Offset Correction: v_off_ini = 679.395 uV, v_off_fin = 675.773 uV 20:57:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.764 uVs 20:57:44 Integrated Voltage Measurement... 20:57:53 Voltage Offset Correction: v_off_ini = 689.457 uV, v_off_fin = 693.818 uV 20:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.700 uVs 20:57:53 Integrated Voltage Measurement... 20:58:02 Voltage Offset Correction: v_off_ini = 679.194 uV, v_off_fin = 676.052 uV 20:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.808 uVs 20:58:02 Integrated Voltage Measurement... 20:58:11 Voltage Offset Correction: v_off_ini = 670.641 uV, v_off_fin = 674.370 uV 20:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.050 uVs 20:58:11 Integrated Voltage Measurement... 20:58:20 Voltage Offset Correction: v_off_ini = 672.846 uV, v_off_fin = 663.759 uV 20:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.996 uVs 20:58:20 Integrated Voltage Measurement... 20:58:29 Voltage Offset Correction: v_off_ini = 662.072 uV, v_off_fin = 660.247 uV 20:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.239 uVs 20:58:33 I1X Average and RMS of Measurements VT = -95.593 +- 12.208 uVs I1X = 19.119 +- 2.441 uTm 20:58:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:58:40 Integrated Voltage Measurement... 20:58:49 Voltage Offset Correction: v_off_ini = 670.512 uV, v_off_fin = 671.313 uV 20:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -199.491 uVs 20:58:49 Integrated Voltage Measurement... 20:58:58 Voltage Offset Correction: v_off_ini = 667.014 uV, v_off_fin = 679.357 uV 20:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.487 uVs 20:58:58 Integrated Voltage Measurement... 20:59:07 Voltage Offset Correction: v_off_ini = 670.167 uV, v_off_fin = 666.768 uV 20:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.192 uVs 20:59:07 Integrated Voltage Measurement... 20:59:16 Voltage Offset Correction: v_off_ini = 655.306 uV, v_off_fin = 656.064 uV 20:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.396 uVs 20:59:16 Integrated Voltage Measurement... 20:59:25 Voltage Offset Correction: v_off_ini = 654.067 uV, v_off_fin = 643.791 uV 20:59:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.573 uVs 20:59:25 Integrated Voltage Measurement... 20:59:34 Voltage Offset Correction: v_off_ini = 655.961 uV, v_off_fin = 657.970 uV 20:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.731 uVs 20:59:38 I1Y Average and RMS of Measurements VT = -200.645 +- 0.605 uVs I1Y = -40.129 +- 0.121 uTm 20:59:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:59:43 Integrated Voltage Measurement... 20:59:52 Voltage Offset Correction: v_off_ini = 644.077 uV, v_off_fin = 651.468 uV 20:59:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.730 uVs 20:59:52 Integrated Voltage Measurement... 21:00:01 Voltage Offset Correction: v_off_ini = 659.691 uV, v_off_fin = 661.774 uV 21:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.625 uVs 21:00:01 Integrated Voltage Measurement... 21:00:10 Voltage Offset Correction: v_off_ini = 652.570 uV, v_off_fin = 658.693 uV 21:00:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.049 uVs 21:00:10 Integrated Voltage Measurement... 21:00:19 Voltage Offset Correction: v_off_ini = 661.156 uV, v_off_fin = 662.726 uV 21:00:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.720 uVs 21:00:19 Integrated Voltage Measurement... 21:00:28 Voltage Offset Correction: v_off_ini = 661.519 uV, v_off_fin = 651.523 uV 21:00:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.088 uVs 21:00:28 Integrated Voltage Measurement... 21:00:37 Voltage Offset Correction: v_off_ini = 651.027 uV, v_off_fin = 644.203 uV 21:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.252 uVs 21:00:40 I2X Average and RMS of Measurements VT = -87.077 +- 12.424 uVs I2X = 8.011 +- 1.143 uTm^2 21:00:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:00:45 Integrated Voltage Measurement... 21:00:54 Voltage Offset Correction: v_off_ini = 641.090 uV, v_off_fin = 643.162 uV 21:00:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.570 uVs 21:00:54 Integrated Voltage Measurement... 21:01:03 Voltage Offset Correction: v_off_ini = 647.458 uV, v_off_fin = 634.609 uV 21:01:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.494 uVs 21:01:03 Integrated Voltage Measurement... 21:01:12 Voltage Offset Correction: v_off_ini = 655.820 uV, v_off_fin = 647.757 uV 21:01:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -468.475 uVs 21:01:12 Integrated Voltage Measurement... 21:01:21 Voltage Offset Correction: v_off_ini = 647.258 uV, v_off_fin = 643.335 uV 21:01:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.657 uVs 21:01:21 Integrated Voltage Measurement... 21:01:30 Voltage Offset Correction: v_off_ini = 649.420 uV, v_off_fin = 646.111 uV 21:01:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.473 uVs 21:01:30 Integrated Voltage Measurement... 21:01:39 Voltage Offset Correction: v_off_ini = 643.996 uV, v_off_fin = 649.966 uV 21:01:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.089 uVs 21:01:42 I2Y Average and RMS of Measurements VT = -461.793 +- 4.919 uVs I2Y = -42.485 +- 0.453 uTm^2 21:01:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:01:50 Integrated Voltage Measurement... 21:01:59 Voltage Offset Correction: v_off_ini = 643.092 uV, v_off_fin = 636.034 uV 21:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.669 uVs 21:01:59 Integrated Voltage Measurement... 21:02:08 Voltage Offset Correction: v_off_ini = 637.342 uV, v_off_fin = 649.255 uV 21:02:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.869 uVs 21:02:08 Integrated Voltage Measurement... 21:02:17 Voltage Offset Correction: v_off_ini = 651.838 uV, v_off_fin = 649.911 uV 21:02:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.897 uVs 21:02:17 Integrated Voltage Measurement... 21:02:26 Voltage Offset Correction: v_off_ini = 659.095 uV, v_off_fin = 675.421 uV 21:02:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.400 uVs 21:02:26 Integrated Voltage Measurement... 21:02:35 Voltage Offset Correction: v_off_ini = 660.428 uV, v_off_fin = 663.987 uV 21:02:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.306 uVs 21:02:35 Integrated Voltage Measurement... 21:02:44 Voltage Offset Correction: v_off_ini = 662.744 uV, v_off_fin = 678.122 uV 21:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.182 uVs 21:02:48 I1X Average and RMS of Measurements VT = -93.887 +- 2.097 uVs I1X = 18.778 +- 0.420 uTm 21:02:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:02:55 Integrated Voltage Measurement... 21:03:04 Voltage Offset Correction: v_off_ini = 661.563 uV, v_off_fin = 642.545 uV 21:03:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.488 uVs 21:03:04 Integrated Voltage Measurement... 21:03:13 Voltage Offset Correction: v_off_ini = 650.622 uV, v_off_fin = 666.235 uV 21:03:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.179 uVs 21:03:13 Integrated Voltage Measurement... 21:03:22 Voltage Offset Correction: v_off_ini = 662.201 uV, v_off_fin = 655.700 uV 21:03:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.355 uVs 21:03:22 Integrated Voltage Measurement... 21:03:31 Voltage Offset Correction: v_off_ini = 655.794 uV, v_off_fin = 665.540 uV 21:03:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.089 uVs 21:03:31 Integrated Voltage Measurement... 21:03:40 Voltage Offset Correction: v_off_ini = 655.201 uV, v_off_fin = 648.584 uV 21:03:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.730 uVs 21:03:40 Integrated Voltage Measurement... 21:03:49 Voltage Offset Correction: v_off_ini = 670.058 uV, v_off_fin = 676.837 uV 21:03:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.831 uVs 21:03:53 I1Y Average and RMS of Measurements VT = -197.279 +- 3.372 uVs I1Y = -39.454 +- 0.676 uTm 21:03:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:03:59 Integrated Voltage Measurement... 21:04:08 Voltage Offset Correction: v_off_ini = 659.309 uV, v_off_fin = 651.234 uV 21:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.416 uVs 21:04:08 Integrated Voltage Measurement... 21:04:17 Voltage Offset Correction: v_off_ini = 658.367 uV, v_off_fin = 675.113 uV 21:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.740 uVs 21:04:17 Integrated Voltage Measurement... 21:04:26 Voltage Offset Correction: v_off_ini = 660.198 uV, v_off_fin = 651.349 uV 21:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.142 uVs 21:04:26 Integrated Voltage Measurement... 21:04:35 Voltage Offset Correction: v_off_ini = 664.859 uV, v_off_fin = 679.253 uV 21:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.897 uVs 21:04:35 Integrated Voltage Measurement... 21:04:44 Voltage Offset Correction: v_off_ini = 679.800 uV, v_off_fin = 677.296 uV 21:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.324 uVs 21:04:44 Integrated Voltage Measurement... 21:04:53 Voltage Offset Correction: v_off_ini = 673.070 uV, v_off_fin = 675.824 uV 21:04:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.815 uVs 21:04:55 I2X Average and RMS of Measurements VT = -82.556 +- 4.626 uVs I2X = 7.595 +- 0.426 uTm^2 21:04:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:05:00 Integrated Voltage Measurement... 21:05:09 Voltage Offset Correction: v_off_ini = 667.605 uV, v_off_fin = 657.336 uV 21:05:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -470.509 uVs 21:05:09 Integrated Voltage Measurement... 21:05:18 Voltage Offset Correction: v_off_ini = 685.935 uV, v_off_fin = 671.477 uV 21:05:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 466.594 uVs 21:05:18 Integrated Voltage Measurement... 21:05:27 Voltage Offset Correction: v_off_ini = 669.906 uV, v_off_fin = 671.276 uV 21:05:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -459.357 uVs 21:05:27 Integrated Voltage Measurement... 21:05:36 Voltage Offset Correction: v_off_ini = 654.321 uV, v_off_fin = 657.338 uV 21:05:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.074 uVs 21:05:36 Integrated Voltage Measurement... 21:05:45 Voltage Offset Correction: v_off_ini = 660.769 uV, v_off_fin = 664.443 uV 21:05:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.501 uVs 21:05:46 Integrated Voltage Measurement... 21:05:55 Voltage Offset Correction: v_off_ini = 657.718 uV, v_off_fin = 662.182 uV 21:05:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 469.678 uVs 21:05:57 I2Y Average and RMS of Measurements VT = -463.286 +- 4.663 uVs I2Y = -42.622 +- 0.429 uTm^2 21:06:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:06:05 Integrated Voltage Measurement... 21:06:14 Voltage Offset Correction: v_off_ini = 670.807 uV, v_off_fin = 655.968 uV 21:06:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.921 uVs 21:06:14 Integrated Voltage Measurement... 21:06:23 Voltage Offset Correction: v_off_ini = 660.971 uV, v_off_fin = 666.072 uV 21:06:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.151 uVs 21:06:23 Integrated Voltage Measurement... 21:06:32 Voltage Offset Correction: v_off_ini = 657.028 uV, v_off_fin = 660.542 uV 21:06:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.111 uVs 21:06:32 Integrated Voltage Measurement... 21:06:41 Voltage Offset Correction: v_off_ini = 662.888 uV, v_off_fin = 669.146 uV 21:06:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.541 uVs 21:06:41 Integrated Voltage Measurement... 21:06:50 Voltage Offset Correction: v_off_ini = 651.933 uV, v_off_fin = 659.978 uV 21:06:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.384 uVs 21:06:50 Integrated Voltage Measurement... 21:06:59 Voltage Offset Correction: v_off_ini = 662.587 uV, v_off_fin = 668.199 uV 21:06:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.377 uVs 21:07:04 I1X Average and RMS of Measurements VT = -89.081 +- 7.925 uVs I1X = 17.817 +- 1.585 uTm 21:07:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:07:10 Integrated Voltage Measurement... 21:07:19 Voltage Offset Correction: v_off_ini = 659.162 uV, v_off_fin = 647.285 uV 21:07:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.336 uVs 21:07:19 Integrated Voltage Measurement... 21:07:28 Voltage Offset Correction: v_off_ini = 665.103 uV, v_off_fin = 667.353 uV 21:07:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.541 uVs 21:07:28 Integrated Voltage Measurement... 21:07:37 Voltage Offset Correction: v_off_ini = 676.382 uV, v_off_fin = 661.792 uV 21:07:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.923 uVs 21:07:37 Integrated Voltage Measurement... 21:07:46 Voltage Offset Correction: v_off_ini = 671.119 uV, v_off_fin = 679.561 uV 21:07:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.968 uVs 21:07:46 Integrated Voltage Measurement... 21:07:55 Voltage Offset Correction: v_off_ini = 685.647 uV, v_off_fin = 662.572 uV 21:07:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.461 uVs 21:07:55 Integrated Voltage Measurement... 21:08:04 Voltage Offset Correction: v_off_ini = 680.761 uV, v_off_fin = 682.041 uV 21:08:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.118 uVs 21:08:09 I1Y Average and RMS of Measurements VT = -194.558 +- 12.541 uVs I1Y = -38.908 +- 2.508 uTm 21:08:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:08:14 Integrated Voltage Measurement... 21:08:23 Voltage Offset Correction: v_off_ini = 667.110 uV, v_off_fin = 660.614 uV 21:08:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.983 uVs 21:08:23 Integrated Voltage Measurement... 21:08:32 Voltage Offset Correction: v_off_ini = 658.088 uV, v_off_fin = 682.947 uV 21:08:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.261 uVs 21:08:32 Integrated Voltage Measurement... 21:08:41 Voltage Offset Correction: v_off_ini = 664.485 uV, v_off_fin = 662.391 uV 21:08:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.560 uVs 21:08:41 Integrated Voltage Measurement... 21:08:50 Voltage Offset Correction: v_off_ini = 656.623 uV, v_off_fin = 675.997 uV 21:08:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.913 uVs 21:08:50 Integrated Voltage Measurement... 21:08:59 Voltage Offset Correction: v_off_ini = 651.882 uV, v_off_fin = 655.760 uV 21:08:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.411 uVs 21:08:59 Integrated Voltage Measurement... 21:09:08 Voltage Offset Correction: v_off_ini = 654.540 uV, v_off_fin = 674.337 uV 21:09:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.307 uVs 21:09:10 I2X Average and RMS of Measurements VT = -71.572 +- 4.767 uVs I2X = 6.585 +- 0.439 uTm^2 21:09:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:09:16 Integrated Voltage Measurement... 21:09:25 Voltage Offset Correction: v_off_ini = 658.045 uV, v_off_fin = 669.005 uV 21:09:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -453.635 uVs 21:09:25 Integrated Voltage Measurement... 21:09:34 Voltage Offset Correction: v_off_ini = 672.639 uV, v_off_fin = 676.479 uV 21:09:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 445.780 uVs 21:09:34 Integrated Voltage Measurement... 21:09:43 Voltage Offset Correction: v_off_ini = 668.440 uV, v_off_fin = 659.297 uV 21:09:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.096 uVs 21:09:43 Integrated Voltage Measurement... 21:09:52 Voltage Offset Correction: v_off_ini = 664.975 uV, v_off_fin = 667.222 uV 21:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.289 uVs 21:09:52 Integrated Voltage Measurement... 21:10:01 Voltage Offset Correction: v_off_ini = 666.369 uV, v_off_fin = 662.588 uV 21:10:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.093 uVs 21:10:01 Integrated Voltage Measurement... 21:10:10 Voltage Offset Correction: v_off_ini = 662.956 uV, v_off_fin = 671.525 uV 21:10:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 470.350 uVs 21:10:12 I2Y Average and RMS of Measurements VT = -449.374 +- 3.694 uVs I2Y = -41.342 +- 0.340 uTm^2 21:10:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:10:34 Integrated Voltage Measurement... 21:10:42 Voltage Offset Correction: v_off_ini = 676.929 uV, v_off_fin = 668.301 uV 21:10:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.475 uVs 21:10:43 Integrated Voltage Measurement... 21:10:52 Voltage Offset Correction: v_off_ini = 676.150 uV, v_off_fin = 674.061 uV 21:10:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.292 uVs 21:10:52 Integrated Voltage Measurement... 21:11:01 Voltage Offset Correction: v_off_ini = 683.148 uV, v_off_fin = 673.692 uV 21:11:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.549 uVs 21:11:01 Integrated Voltage Measurement... 21:11:10 Voltage Offset Correction: v_off_ini = 674.684 uV, v_off_fin = 672.878 uV 21:11:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.660 uVs 21:11:10 Integrated Voltage Measurement... 21:11:19 Voltage Offset Correction: v_off_ini = 671.709 uV, v_off_fin = 677.852 uV 21:11:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.022 uVs 21:11:19 Integrated Voltage Measurement... 21:11:28 Voltage Offset Correction: v_off_ini = 684.418 uV, v_off_fin = 677.880 uV 21:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.428 uVs 21:11:32 I1X Average and RMS of Measurements VT = -105.238 +- 5.866 uVs I1X = 21.048 +- 1.173 uTm 21:11:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:11:39 Integrated Voltage Measurement... 21:11:48 Voltage Offset Correction: v_off_ini = 671.130 uV, v_off_fin = 667.881 uV 21:11:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -188.422 uVs 21:11:48 Integrated Voltage Measurement... 21:11:57 Voltage Offset Correction: v_off_ini = 670.024 uV, v_off_fin = 688.922 uV 21:11:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.154 uVs 21:11:57 Integrated Voltage Measurement... 21:12:06 Voltage Offset Correction: v_off_ini = 686.113 uV, v_off_fin = 686.516 uV 21:12:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.170 uVs 21:12:06 Integrated Voltage Measurement... 21:12:15 Voltage Offset Correction: v_off_ini = 676.268 uV, v_off_fin = 688.232 uV 21:12:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.038 uVs 21:12:15 Integrated Voltage Measurement... 21:12:24 Voltage Offset Correction: v_off_ini = 674.966 uV, v_off_fin = 657.049 uV 21:12:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.126 uVs 21:12:24 Integrated Voltage Measurement... 21:12:33 Voltage Offset Correction: v_off_ini = 683.169 uV, v_off_fin = 686.808 uV 21:12:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.283 uVs 21:12:37 I1Y Average and RMS of Measurements VT = -194.532 +- 6.085 uVs I1Y = -38.907 +- 1.217 uTm 21:12:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:12:45 Integrated Voltage Measurement... 21:12:54 Voltage Offset Correction: v_off_ini = 658.538 uV, v_off_fin = 664.916 uV 21:12:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.556 uVs 21:12:54 Integrated Voltage Measurement... 21:13:03 Voltage Offset Correction: v_off_ini = 660.472 uV, v_off_fin = 679.712 uV 21:13:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.598 uVs 21:13:03 Integrated Voltage Measurement... 21:13:12 Voltage Offset Correction: v_off_ini = 661.359 uV, v_off_fin = 662.773 uV 21:13:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.375 uVs 21:13:12 Integrated Voltage Measurement... 21:13:21 Voltage Offset Correction: v_off_ini = 673.043 uV, v_off_fin = 669.541 uV 21:13:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.553 uVs 21:13:21 Integrated Voltage Measurement... 21:13:30 Voltage Offset Correction: v_off_ini = 666.269 uV, v_off_fin = 645.899 uV 21:13:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.661 uVs 21:13:30 Integrated Voltage Measurement... 21:13:39 Voltage Offset Correction: v_off_ini = 655.763 uV, v_off_fin = 672.816 uV 21:13:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.366 uVs 21:13:41 I2X Average and RMS of Measurements VT = -84.685 +- 12.080 uVs I2X = 7.791 +- 1.111 uTm^2 21:13:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:13:49 Integrated Voltage Measurement... 21:13:58 Voltage Offset Correction: v_off_ini = 660.311 uV, v_off_fin = 660.386 uV 21:13:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.726 uVs 21:13:58 Integrated Voltage Measurement... 21:14:07 Voltage Offset Correction: v_off_ini = 667.072 uV, v_off_fin = 667.017 uV 21:14:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 433.319 uVs 21:14:07 Integrated Voltage Measurement... 21:14:16 Voltage Offset Correction: v_off_ini = 673.608 uV, v_off_fin = 664.647 uV 21:14:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -448.096 uVs 21:14:16 Integrated Voltage Measurement... 21:14:25 Voltage Offset Correction: v_off_ini = 657.479 uV, v_off_fin = 671.147 uV 21:14:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.198 uVs 21:14:25 Integrated Voltage Measurement... 21:14:34 Voltage Offset Correction: v_off_ini = 668.383 uV, v_off_fin = 663.313 uV 21:14:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.847 uVs 21:14:34 Integrated Voltage Measurement... 21:14:43 Voltage Offset Correction: v_off_ini = 657.656 uV, v_off_fin = 668.285 uV 21:14:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.223 uVs 21:14:46 I2Y Average and RMS of Measurements VT = -440.902 +- 9.817 uVs I2Y = -40.563 +- 0.903 uTm^2 21:14:50 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:14:55 Integrated Voltage Measurement... 21:15:04 Voltage Offset Correction: v_off_ini = 672.772 uV, v_off_fin = 655.815 uV 21:15:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.433 uVs 21:15:04 Integrated Voltage Measurement... 21:15:13 Voltage Offset Correction: v_off_ini = 649.693 uV, v_off_fin = 665.623 uV 21:15:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.826 uVs 21:15:13 Integrated Voltage Measurement... 21:15:22 Voltage Offset Correction: v_off_ini = 651.388 uV, v_off_fin = 646.889 uV 21:15:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.824 uVs 21:15:22 Integrated Voltage Measurement... 21:15:31 Voltage Offset Correction: v_off_ini = 654.992 uV, v_off_fin = 664.936 uV 21:15:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.999 uVs 21:15:31 Integrated Voltage Measurement... 21:15:40 Voltage Offset Correction: v_off_ini = 657.528 uV, v_off_fin = 651.944 uV 21:15:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.215 uVs 21:15:40 Integrated Voltage Measurement... 21:15:49 Voltage Offset Correction: v_off_ini = 657.294 uV, v_off_fin = 668.578 uV 21:15:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.888 uVs 21:15:53 I1X Average and RMS of Measurements VT = -109.531 +- 9.284 uVs I1X = 21.907 +- 1.857 uTm 21:15:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:16:00 Integrated Voltage Measurement... 21:16:09 Voltage Offset Correction: v_off_ini = 661.141 uV, v_off_fin = 650.132 uV 21:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.705 uVs 21:16:09 Integrated Voltage Measurement... 21:16:18 Voltage Offset Correction: v_off_ini = 652.523 uV, v_off_fin = 658.393 uV 21:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 205.206 uVs 21:16:18 Integrated Voltage Measurement... 21:16:27 Voltage Offset Correction: v_off_ini = 657.680 uV, v_off_fin = 657.060 uV 21:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.740 uVs 21:16:27 Integrated Voltage Measurement... 21:16:36 Voltage Offset Correction: v_off_ini = 672.163 uV, v_off_fin = 671.013 uV 21:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.328 uVs 21:16:36 Integrated Voltage Measurement... 21:16:45 Voltage Offset Correction: v_off_ini = 662.841 uV, v_off_fin = 659.514 uV 21:16:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.502 uVs 21:16:45 Integrated Voltage Measurement... 21:16:54 Voltage Offset Correction: v_off_ini = 648.567 uV, v_off_fin = 650.643 uV 21:16:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.298 uVs 21:16:58 I1Y Average and RMS of Measurements VT = -207.130 +- 1.931 uVs I1Y = -41.427 +- 0.387 uTm 21:17:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:17:06 Integrated Voltage Measurement... 21:17:15 Voltage Offset Correction: v_off_ini = 647.121 uV, v_off_fin = 641.349 uV 21:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.459 uVs 21:17:15 Integrated Voltage Measurement... 21:17:24 Voltage Offset Correction: v_off_ini = 645.186 uV, v_off_fin = 659.645 uV 21:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.393 uVs 21:17:24 Integrated Voltage Measurement... 21:17:33 Voltage Offset Correction: v_off_ini = 636.830 uV, v_off_fin = 624.905 uV 21:17:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.454 uVs 21:17:33 Integrated Voltage Measurement... 21:17:42 Voltage Offset Correction: v_off_ini = 637.266 uV, v_off_fin = 643.022 uV 21:17:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.393 uVs 21:17:42 Integrated Voltage Measurement... 21:17:51 Voltage Offset Correction: v_off_ini = 641.341 uV, v_off_fin = 626.042 uV 21:17:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.573 uVs 21:17:51 Integrated Voltage Measurement... 21:18:00 Voltage Offset Correction: v_off_ini = 640.843 uV, v_off_fin = 641.990 uV 21:18:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.693 uVs 21:18:02 I2X Average and RMS of Measurements VT = -89.161 +- 1.729 uVs I2X = 8.203 +- 0.159 uTm^2 21:18:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:18:10 Integrated Voltage Measurement... 21:18:19 Voltage Offset Correction: v_off_ini = 638.722 uV, v_off_fin = 640.339 uV 21:18:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.231 uVs 21:18:19 Integrated Voltage Measurement... 21:18:28 Voltage Offset Correction: v_off_ini = 659.429 uV, v_off_fin = 649.821 uV 21:18:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 435.922 uVs 21:18:28 Integrated Voltage Measurement... 21:18:37 Voltage Offset Correction: v_off_ini = 643.810 uV, v_off_fin = 649.692 uV 21:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.435 uVs 21:18:37 Integrated Voltage Measurement... 21:18:46 Voltage Offset Correction: v_off_ini = 649.092 uV, v_off_fin = 655.401 uV 21:18:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 428.050 uVs 21:18:46 Integrated Voltage Measurement... 21:18:55 Voltage Offset Correction: v_off_ini = 644.324 uV, v_off_fin = 647.874 uV 21:18:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.597 uVs 21:18:55 Integrated Voltage Measurement... 21:19:04 Voltage Offset Correction: v_off_ini = 643.707 uV, v_off_fin = 643.771 uV 21:19:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.493 uVs 21:19:07 I2Y Average and RMS of Measurements VT = -442.121 +- 4.742 uVs I2Y = -40.675 +- 0.436 uTm^2 21:19:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:19:16 Integrated Voltage Measurement... 21:19:25 Voltage Offset Correction: v_off_ini = 651.782 uV, v_off_fin = 649.759 uV 21:19:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -104.306 uVs 21:19:25 Integrated Voltage Measurement... 21:19:34 Voltage Offset Correction: v_off_ini = 648.897 uV, v_off_fin = 648.495 uV 21:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.808 uVs 21:19:34 Integrated Voltage Measurement... 21:19:43 Voltage Offset Correction: v_off_ini = 655.768 uV, v_off_fin = 644.325 uV 21:19:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.375 uVs 21:19:43 Integrated Voltage Measurement... 21:19:52 Voltage Offset Correction: v_off_ini = 649.559 uV, v_off_fin = 649.651 uV 21:19:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.689 uVs 21:19:52 Integrated Voltage Measurement... 21:20:01 Voltage Offset Correction: v_off_ini = 638.375 uV, v_off_fin = 636.805 uV 21:20:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.310 uVs 21:20:01 Integrated Voltage Measurement... 21:20:10 Voltage Offset Correction: v_off_ini = 648.715 uV, v_off_fin = 661.691 uV 21:20:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.866 uVs 21:20:14 I1X Average and RMS of Measurements VT = -103.726 +- 4.087 uVs I1X = 20.746 +- 0.817 uTm 21:20:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:20:21 Integrated Voltage Measurement... 21:20:30 Voltage Offset Correction: v_off_ini = 651.820 uV, v_off_fin = 645.048 uV 21:20:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.918 uVs 21:20:30 Integrated Voltage Measurement... 21:20:39 Voltage Offset Correction: v_off_ini = 652.759 uV, v_off_fin = 662.856 uV 21:20:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.647 uVs 21:20:39 Integrated Voltage Measurement... 21:20:48 Voltage Offset Correction: v_off_ini = 653.445 uV, v_off_fin = 650.110 uV 21:20:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -200.410 uVs 21:20:48 Integrated Voltage Measurement... 21:20:57 Voltage Offset Correction: v_off_ini = 646.947 uV, v_off_fin = 654.310 uV 21:20:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.462 uVs 21:20:57 Integrated Voltage Measurement... 21:21:06 Voltage Offset Correction: v_off_ini = 650.129 uV, v_off_fin = 631.509 uV 21:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.010 uVs 21:21:06 Integrated Voltage Measurement... 21:21:15 Voltage Offset Correction: v_off_ini = 643.625 uV, v_off_fin = 654.722 uV 21:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.650 uVs 21:21:19 I1Y Average and RMS of Measurements VT = -201.183 +- 0.959 uVs I1Y = -40.237 +- 0.192 uTm 21:21:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:21:27 Integrated Voltage Measurement... 21:21:36 Voltage Offset Correction: v_off_ini = 640.851 uV, v_off_fin = 643.252 uV 21:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.444 uVs 21:21:36 Integrated Voltage Measurement... 21:21:45 Voltage Offset Correction: v_off_ini = 648.102 uV, v_off_fin = 651.550 uV 21:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.921 uVs 21:21:45 Integrated Voltage Measurement... 21:21:54 Voltage Offset Correction: v_off_ini = 635.916 uV, v_off_fin = 639.989 uV 21:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.053 uVs 21:21:54 Integrated Voltage Measurement... 21:22:03 Voltage Offset Correction: v_off_ini = 649.158 uV, v_off_fin = 644.308 uV 21:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.461 uVs 21:22:03 Integrated Voltage Measurement... 21:22:12 Voltage Offset Correction: v_off_ini = 655.457 uV, v_off_fin = 641.085 uV 21:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.511 uVs 21:22:12 Integrated Voltage Measurement... 21:22:21 Voltage Offset Correction: v_off_ini = 656.701 uV, v_off_fin = 659.876 uV 21:22:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.830 uVs 21:22:24 I2X Average and RMS of Measurements VT = -94.703 +- 9.510 uVs I2X = 8.713 +- 0.875 uTm^2 21:22:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:22:31 Integrated Voltage Measurement... 21:22:40 Voltage Offset Correction: v_off_ini = 651.048 uV, v_off_fin = 663.654 uV 21:22:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.064 uVs 21:22:40 Integrated Voltage Measurement... 21:22:49 Voltage Offset Correction: v_off_ini = 654.724 uV, v_off_fin = 641.921 uV 21:22:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.742 uVs 21:22:49 Integrated Voltage Measurement... 21:22:58 Voltage Offset Correction: v_off_ini = 636.062 uV, v_off_fin = 644.913 uV 21:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.035 uVs 21:22:58 Integrated Voltage Measurement... 21:23:07 Voltage Offset Correction: v_off_ini = 656.716 uV, v_off_fin = 649.377 uV 21:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 438.210 uVs 21:23:07 Integrated Voltage Measurement... 21:23:16 Voltage Offset Correction: v_off_ini = 652.742 uV, v_off_fin = 650.909 uV 21:23:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.771 uVs 21:23:17 Integrated Voltage Measurement... 21:23:26 Voltage Offset Correction: v_off_ini = 653.326 uV, v_off_fin = 648.203 uV 21:23:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.081 uVs 21:23:28 I2Y Average and RMS of Measurements VT = -441.151 +- 2.031 uVs I2Y = -40.586 +- 0.187 uTm^2 21:23:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:23:37 Integrated Voltage Measurement... 21:23:46 Voltage Offset Correction: v_off_ini = 650.195 uV, v_off_fin = 653.268 uV 21:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.860 uVs 21:23:46 Integrated Voltage Measurement... 21:23:55 Voltage Offset Correction: v_off_ini = 658.472 uV, v_off_fin = 659.225 uV 21:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.897 uVs 21:23:55 Integrated Voltage Measurement... 21:24:04 Voltage Offset Correction: v_off_ini = 649.079 uV, v_off_fin = 640.175 uV 21:24:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.682 uVs 21:24:04 Integrated Voltage Measurement... 21:24:13 Voltage Offset Correction: v_off_ini = 663.569 uV, v_off_fin = 659.578 uV 21:24:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.329 uVs 21:24:13 Integrated Voltage Measurement... 21:24:22 Voltage Offset Correction: v_off_ini = 653.970 uV, v_off_fin = 660.098 uV 21:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.070 uVs 21:24:22 Integrated Voltage Measurement... 21:24:31 Voltage Offset Correction: v_off_ini = 658.271 uV, v_off_fin = 662.320 uV 21:24:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.502 uVs 21:24:35 I1X Average and RMS of Measurements VT = -97.390 +- 1.145 uVs I1X = 19.478 +- 0.229 uTm 21:24:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:24:42 Integrated Voltage Measurement... 21:24:51 Voltage Offset Correction: v_off_ini = 653.340 uV, v_off_fin = 650.315 uV 21:24:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.029 uVs 21:24:51 Integrated Voltage Measurement... 21:25:00 Voltage Offset Correction: v_off_ini = 670.983 uV, v_off_fin = 688.337 uV 21:25:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.845 uVs 21:25:00 Integrated Voltage Measurement... 21:25:09 Voltage Offset Correction: v_off_ini = 674.040 uV, v_off_fin = 664.630 uV 21:25:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.166 uVs 21:25:09 Integrated Voltage Measurement... 21:25:18 Voltage Offset Correction: v_off_ini = 669.095 uV, v_off_fin = 671.488 uV 21:25:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.625 uVs 21:25:18 Integrated Voltage Measurement... 21:25:27 Voltage Offset Correction: v_off_ini = 649.859 uV, v_off_fin = 650.693 uV 21:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.069 uVs 21:25:27 Integrated Voltage Measurement... 21:25:36 Voltage Offset Correction: v_off_ini = 656.400 uV, v_off_fin = 666.944 uV 21:25:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.265 uVs 21:25:40 I1Y Average and RMS of Measurements VT = -197.333 +- 2.538 uVs I1Y = -39.467 +- 0.508 uTm 21:25:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:25:48 Integrated Voltage Measurement... 21:25:57 Voltage Offset Correction: v_off_ini = 652.524 uV, v_off_fin = 648.434 uV 21:25:57 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -104.880 uVs 21:25:57 Integrated Voltage Measurement... 21:26:06 Voltage Offset Correction: v_off_ini = 656.833 uV, v_off_fin = 673.033 uV 21:26:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.687 uVs 21:26:06 Integrated Voltage Measurement... 21:26:15 Voltage Offset Correction: v_off_ini = 676.750 uV, v_off_fin = 646.573 uV 21:26:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.577 uVs 21:26:15 Integrated Voltage Measurement... 21:26:24 Voltage Offset Correction: v_off_ini = 656.370 uV, v_off_fin = 671.139 uV 21:26:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.497 uVs 21:26:24 Integrated Voltage Measurement... 21:26:33 Voltage Offset Correction: v_off_ini = 663.737 uV, v_off_fin = 647.050 uV 21:26:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.054 uVs 21:26:33 Integrated Voltage Measurement... 21:26:42 Voltage Offset Correction: v_off_ini = 660.152 uV, v_off_fin = 666.660 uV 21:26:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.333 uVs 21:26:45 I2X Average and RMS of Measurements VT = -96.671 +- 3.029 uVs I2X = 8.894 +- 0.279 uTm^2 21:26:50 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 21:26:52 Integrated Voltage Measurement... 21:27:01 Voltage Offset Correction: v_off_ini = 666.159 uV, v_off_fin = 675.897 uV 21:27:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.576 uVs 21:27:01 Integrated Voltage Measurement... 21:27:10 Voltage Offset Correction: v_off_ini = 676.518 uV, v_off_fin = 683.146 uV 21:27:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.090 uVs 21:27:10 Integrated Voltage Measurement... 21:27:19 Voltage Offset Correction: v_off_ini = 663.063 uV, v_off_fin = 671.189 uV 21:27:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -434.313 uVs 21:27:19 Integrated Voltage Measurement... 21:27:28 Voltage Offset Correction: v_off_ini = 661.146 uV, v_off_fin = 678.193 uV 21:27:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.476 uVs 21:27:29 Integrated Voltage Measurement... 21:27:38 Voltage Offset Correction: v_off_ini = 673.640 uV, v_off_fin = 670.849 uV 21:27:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.560 uVs 21:27:38 Integrated Voltage Measurement... 21:27:47 Voltage Offset Correction: v_off_ini = 669.249 uV, v_off_fin = 669.529 uV 21:27:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.071 uVs 21:27:49 I2Y Average and RMS of Measurements VT = -438.848 +- 2.973 uVs I2Y = -40.374 +- 0.273 uTm^2 21:27:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:27:58 Integrated Voltage Measurement... 21:28:07 Voltage Offset Correction: v_off_ini = 665.627 uV, v_off_fin = 676.464 uV 21:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.859 uVs 21:28:07 Integrated Voltage Measurement... 21:28:16 Voltage Offset Correction: v_off_ini = 662.046 uV, v_off_fin = 664.006 uV 21:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.972 uVs 21:28:16 Integrated Voltage Measurement... 21:28:25 Voltage Offset Correction: v_off_ini = 667.502 uV, v_off_fin = 663.338 uV 21:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.718 uVs 21:28:25 Integrated Voltage Measurement... 21:28:34 Voltage Offset Correction: v_off_ini = 659.432 uV, v_off_fin = 654.706 uV 21:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.971 uVs 21:28:34 Integrated Voltage Measurement... 21:28:43 Voltage Offset Correction: v_off_ini = 660.727 uV, v_off_fin = 656.688 uV 21:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.390 uVs 21:28:43 Integrated Voltage Measurement... 21:28:52 Voltage Offset Correction: v_off_ini = 648.515 uV, v_off_fin = 648.905 uV 21:28:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.059 uVs 21:28:56 I1X Average and RMS of Measurements VT = -111.828 +- 1.830 uVs I1X = 22.366 +- 0.366 uTm 21:28:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:29:03 Integrated Voltage Measurement... 21:29:12 Voltage Offset Correction: v_off_ini = 654.676 uV, v_off_fin = 637.629 uV 21:29:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.192 uVs 21:29:12 Integrated Voltage Measurement... 21:29:21 Voltage Offset Correction: v_off_ini = 637.929 uV, v_off_fin = 653.456 uV 21:29:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.234 uVs 21:29:21 Integrated Voltage Measurement... 21:29:30 Voltage Offset Correction: v_off_ini = 645.116 uV, v_off_fin = 624.027 uV 21:29:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.097 uVs 21:29:30 Integrated Voltage Measurement... 21:29:39 Voltage Offset Correction: v_off_ini = 635.407 uV, v_off_fin = 654.877 uV 21:29:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.040 uVs 21:29:39 Integrated Voltage Measurement... 21:29:48 Voltage Offset Correction: v_off_ini = 638.172 uV, v_off_fin = 640.174 uV 21:29:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.670 uVs 21:29:48 Integrated Voltage Measurement... 21:29:57 Voltage Offset Correction: v_off_ini = 653.623 uV, v_off_fin = 645.378 uV 21:29:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.480 uVs 21:30:01 I1Y Average and RMS of Measurements VT = -192.786 +- 3.938 uVs I1Y = -38.557 +- 0.788 uTm 21:30:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:30:09 Integrated Voltage Measurement... 21:30:18 Voltage Offset Correction: v_off_ini = 640.816 uV, v_off_fin = 637.838 uV 21:30:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -107.069 uVs 21:30:18 Integrated Voltage Measurement... 21:30:27 Voltage Offset Correction: v_off_ini = 640.538 uV, v_off_fin = 645.282 uV 21:30:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.152 uVs 21:30:27 Integrated Voltage Measurement... 21:30:36 Voltage Offset Correction: v_off_ini = 645.477 uV, v_off_fin = 639.709 uV 21:30:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.103 uVs 21:30:36 Integrated Voltage Measurement... 21:30:45 Voltage Offset Correction: v_off_ini = 649.214 uV, v_off_fin = 648.647 uV 21:30:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.863 uVs 21:30:45 Integrated Voltage Measurement... 21:30:54 Voltage Offset Correction: v_off_ini = 642.103 uV, v_off_fin = 638.513 uV 21:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.591 uVs 21:30:54 Integrated Voltage Measurement... 21:31:03 Voltage Offset Correction: v_off_ini = 645.267 uV, v_off_fin = 643.649 uV 21:31:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.936 uVs 21:31:06 I2X Average and RMS of Measurements VT = -97.952 +- 3.960 uVs I2X = 9.011 +- 0.364 uTm^2 21:31:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 21:31:13 Integrated Voltage Measurement... 21:31:22 Voltage Offset Correction: v_off_ini = 620.737 uV, v_off_fin = 604.707 uV 21:31:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.981 uVs 21:31:22 Integrated Voltage Measurement... 21:31:31 Voltage Offset Correction: v_off_ini = 618.728 uV, v_off_fin = 632.318 uV 21:31:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 452.251 uVs 21:31:32 Integrated Voltage Measurement... 21:31:40 Voltage Offset Correction: v_off_ini = 630.629 uV, v_off_fin = 638.638 uV 21:31:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -438.776 uVs 21:31:41 Integrated Voltage Measurement... 21:31:50 Voltage Offset Correction: v_off_ini = 645.631 uV, v_off_fin = 629.816 uV 21:31:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.499 uVs 21:31:50 Integrated Voltage Measurement... 21:31:59 Voltage Offset Correction: v_off_ini = 631.109 uV, v_off_fin = 631.836 uV 21:31:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.623 uVs 21:31:59 Integrated Voltage Measurement... 21:32:08 Voltage Offset Correction: v_off_ini = 644.375 uV, v_off_fin = 641.072 uV 21:32:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.343 uVs 21:32:10 I2Y Average and RMS of Measurements VT = -443.579 +- 4.361 uVs I2Y = -40.809 +- 0.401 uTm^2 21:32:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:32:22 Integrated Voltage Measurement... 21:32:31 Voltage Offset Correction: v_off_ini = 637.156 uV, v_off_fin = 625.856 uV 21:32:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -88.583 uVs 21:32:31 Integrated Voltage Measurement... 21:32:40 Voltage Offset Correction: v_off_ini = 637.136 uV, v_off_fin = 644.599 uV 21:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.263 uVs 21:32:40 Integrated Voltage Measurement... 21:32:49 Voltage Offset Correction: v_off_ini = 645.752 uV, v_off_fin = 641.634 uV 21:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.945 uVs 21:32:49 Integrated Voltage Measurement... 21:32:58 Voltage Offset Correction: v_off_ini = 639.554 uV, v_off_fin = 640.650 uV 21:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.276 uVs 21:32:58 Integrated Voltage Measurement... 21:33:07 Voltage Offset Correction: v_off_ini = 625.683 uV, v_off_fin = 617.481 uV 21:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.003 uVs 21:33:07 Integrated Voltage Measurement... 21:33:16 Voltage Offset Correction: v_off_ini = 638.042 uV, v_off_fin = 634.186 uV 21:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.501 uVs 21:33:20 I1X Average and RMS of Measurements VT = -91.429 +- 5.045 uVs I1X = 18.287 +- 1.009 uTm 21:33:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:33:27 Integrated Voltage Measurement... 21:33:36 Voltage Offset Correction: v_off_ini = 637.401 uV, v_off_fin = 640.110 uV 21:33:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.599 uVs 21:33:36 Integrated Voltage Measurement... 21:33:45 Voltage Offset Correction: v_off_ini = 644.551 uV, v_off_fin = 654.993 uV 21:33:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.465 uVs 21:33:45 Integrated Voltage Measurement... 21:33:54 Voltage Offset Correction: v_off_ini = 640.589 uV, v_off_fin = 631.368 uV 21:33:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.182 uVs 21:33:54 Integrated Voltage Measurement... 21:34:03 Voltage Offset Correction: v_off_ini = 630.492 uV, v_off_fin = 636.663 uV 21:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.596 uVs 21:34:03 Integrated Voltage Measurement... 21:34:12 Voltage Offset Correction: v_off_ini = 645.574 uV, v_off_fin = 630.275 uV 21:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.899 uVs 21:34:12 Integrated Voltage Measurement... 21:34:21 Voltage Offset Correction: v_off_ini = 634.828 uV, v_off_fin = 634.854 uV 21:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.077 uVs 21:34:25 I1Y Average and RMS of Measurements VT = -195.303 +- 4.111 uVs I1Y = -39.061 +- 0.822 uTm 21:34:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:34:31 Integrated Voltage Measurement... 21:34:40 Voltage Offset Correction: v_off_ini = 628.431 uV, v_off_fin = 624.194 uV 21:34:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.044 uVs 21:34:40 Integrated Voltage Measurement... 21:34:49 Voltage Offset Correction: v_off_ini = 634.938 uV, v_off_fin = 635.686 uV 21:34:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.892 uVs 21:34:49 Integrated Voltage Measurement... 21:34:58 Voltage Offset Correction: v_off_ini = 637.442 uV, v_off_fin = 625.432 uV 21:34:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.612 uVs 21:34:58 Integrated Voltage Measurement... 21:35:07 Voltage Offset Correction: v_off_ini = 636.403 uV, v_off_fin = 636.040 uV 21:35:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.133 uVs 21:35:07 Integrated Voltage Measurement... 21:35:16 Voltage Offset Correction: v_off_ini = 613.280 uV, v_off_fin = 604.518 uV 21:35:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.885 uVs 21:35:16 Integrated Voltage Measurement... 21:35:25 Voltage Offset Correction: v_off_ini = 637.038 uV, v_off_fin = 620.030 uV 21:35:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.363 uVs 21:35:27 I2X Average and RMS of Measurements VT = -86.488 +- 10.129 uVs I2X = 7.957 +- 0.932 uTm^2 21:35:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 21:35:32 Integrated Voltage Measurement... 21:35:41 Voltage Offset Correction: v_off_ini = 607.113 uV, v_off_fin = 613.704 uV 21:35:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -432.031 uVs 21:35:41 Integrated Voltage Measurement... 21:35:50 Voltage Offset Correction: v_off_ini = 622.024 uV, v_off_fin = 609.042 uV 21:35:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 445.970 uVs 21:35:51 Integrated Voltage Measurement... 21:35:59 Voltage Offset Correction: v_off_ini = 614.829 uV, v_off_fin = 610.221 uV 21:36:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -443.580 uVs 21:36:00 Integrated Voltage Measurement... 21:36:09 Voltage Offset Correction: v_off_ini = 614.274 uV, v_off_fin = 602.485 uV 21:36:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.795 uVs 21:36:09 Integrated Voltage Measurement... 21:36:18 Voltage Offset Correction: v_off_ini = 605.854 uV, v_off_fin = 602.440 uV 21:36:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.352 uVs 21:36:18 Integrated Voltage Measurement... 21:36:27 Voltage Offset Correction: v_off_ini = 603.247 uV, v_off_fin = 604.592 uV 21:36:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.698 uVs 21:36:29 I2Y Average and RMS of Measurements VT = -441.238 +- 1.919 uVs I2Y = -40.595 +- 0.176 uTm^2 21:36:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:36:37 Integrated Voltage Measurement... 21:36:46 Voltage Offset Correction: v_off_ini = 604.586 uV, v_off_fin = 603.513 uV 21:36:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -100.072 uVs 21:36:46 Integrated Voltage Measurement... 21:36:55 Voltage Offset Correction: v_off_ini = 610.204 uV, v_off_fin = 600.261 uV 21:36:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.852 uVs 21:36:56 Integrated Voltage Measurement... 21:37:04 Voltage Offset Correction: v_off_ini = 606.801 uV, v_off_fin = 601.743 uV 21:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.534 uVs 21:37:05 Integrated Voltage Measurement... 21:37:13 Voltage Offset Correction: v_off_ini = 606.728 uV, v_off_fin = 605.247 uV 21:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 98.221 uVs 21:37:14 Integrated Voltage Measurement... 21:37:23 Voltage Offset Correction: v_off_ini = 598.670 uV, v_off_fin = 604.694 uV 21:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.971 uVs 21:37:23 Integrated Voltage Measurement... 21:37:32 Voltage Offset Correction: v_off_ini = 604.026 uV, v_off_fin = 606.137 uV 21:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.964 uVs 21:37:36 I1X Average and RMS of Measurements VT = -96.102 +- 5.130 uVs I1X = 19.222 +- 1.026 uTm 21:37:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:37:43 Integrated Voltage Measurement... 21:37:52 Voltage Offset Correction: v_off_ini = 603.199 uV, v_off_fin = 592.952 uV 21:37:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.789 uVs 21:37:52 Integrated Voltage Measurement... 21:38:01 Voltage Offset Correction: v_off_ini = 600.022 uV, v_off_fin = 617.197 uV 21:38:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.203 uVs 21:38:01 Integrated Voltage Measurement... 21:38:10 Voltage Offset Correction: v_off_ini = 609.113 uV, v_off_fin = 598.776 uV 21:38:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.542 uVs 21:38:10 Integrated Voltage Measurement... 21:38:19 Voltage Offset Correction: v_off_ini = 603.132 uV, v_off_fin = 614.705 uV 21:38:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.766 uVs 21:38:19 Integrated Voltage Measurement... 21:38:28 Voltage Offset Correction: v_off_ini = 599.749 uV, v_off_fin = 593.243 uV 21:38:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.133 uVs 21:38:28 Integrated Voltage Measurement... 21:38:37 Voltage Offset Correction: v_off_ini = 604.924 uV, v_off_fin = 613.876 uV 21:38:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.262 uVs 21:38:41 I1Y Average and RMS of Measurements VT = -198.949 +- 1.964 uVs I1Y = -39.790 +- 0.393 uTm 21:38:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:38:46 Integrated Voltage Measurement... 21:38:55 Voltage Offset Correction: v_off_ini = 601.187 uV, v_off_fin = 598.100 uV 21:38:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.411 uVs 21:38:55 Integrated Voltage Measurement... 21:39:04 Voltage Offset Correction: v_off_ini = 608.692 uV, v_off_fin = 607.742 uV 21:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.399 uVs 21:39:04 Integrated Voltage Measurement... 21:39:13 Voltage Offset Correction: v_off_ini = 609.563 uV, v_off_fin = 595.374 uV 21:39:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.142 uVs 21:39:13 Integrated Voltage Measurement... 21:39:22 Voltage Offset Correction: v_off_ini = 611.282 uV, v_off_fin = 606.804 uV 21:39:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.209 uVs 21:39:22 Integrated Voltage Measurement... 21:39:31 Voltage Offset Correction: v_off_ini = 601.208 uV, v_off_fin = 596.548 uV 21:39:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.544 uVs 21:39:31 Integrated Voltage Measurement... 21:39:40 Voltage Offset Correction: v_off_ini = 602.376 uV, v_off_fin = 610.956 uV 21:39:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.249 uVs 21:39:43 I2X Average and RMS of Measurements VT = -90.159 +- 3.357 uVs I2X = 8.295 +- 0.309 uTm^2 21:39:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 21:39:48 Integrated Voltage Measurement... 21:39:57 Voltage Offset Correction: v_off_ini = 582.646 uV, v_off_fin = 587.448 uV 21:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -424.223 uVs 21:39:57 Integrated Voltage Measurement... 21:40:06 Voltage Offset Correction: v_off_ini = 589.516 uV, v_off_fin = 591.864 uV 21:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.356 uVs 21:40:06 Integrated Voltage Measurement... 21:40:15 Voltage Offset Correction: v_off_ini = 597.375 uV, v_off_fin = 592.300 uV 21:40:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.113 uVs 21:40:15 Integrated Voltage Measurement... 21:40:24 Voltage Offset Correction: v_off_ini = 605.411 uV, v_off_fin = 602.688 uV 21:40:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 428.420 uVs 21:40:24 Integrated Voltage Measurement... 21:40:33 Voltage Offset Correction: v_off_ini = 594.753 uV, v_off_fin = 599.482 uV 21:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.385 uVs 21:40:33 Integrated Voltage Measurement... 21:40:42 Voltage Offset Correction: v_off_ini = 599.312 uV, v_off_fin = 599.548 uV 21:40:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.887 uVs 21:40:44 I2Y Average and RMS of Measurements VT = -438.064 +- 1.968 uVs I2Y = -40.302 +- 0.181 uTm^2 21:40:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:40:53 Integrated Voltage Measurement... 21:41:02 Voltage Offset Correction: v_off_ini = 597.990 uV, v_off_fin = 596.874 uV 21:41:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.834 uVs 21:41:02 Integrated Voltage Measurement... 21:41:11 Voltage Offset Correction: v_off_ini = 603.758 uV, v_off_fin = 597.746 uV 21:41:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.419 uVs 21:41:11 Integrated Voltage Measurement... 21:41:20 Voltage Offset Correction: v_off_ini = 588.425 uV, v_off_fin = 588.944 uV 21:41:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.958 uVs 21:41:20 Integrated Voltage Measurement... 21:41:29 Voltage Offset Correction: v_off_ini = 601.406 uV, v_off_fin = 603.511 uV 21:41:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.834 uVs 21:41:29 Integrated Voltage Measurement... 21:41:38 Voltage Offset Correction: v_off_ini = 612.243 uV, v_off_fin = 600.932 uV 21:41:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.239 uVs 21:41:38 Integrated Voltage Measurement... 21:41:47 Voltage Offset Correction: v_off_ini = 609.147 uV, v_off_fin = 601.847 uV 21:41:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.654 uVs 21:41:51 I1X Average and RMS of Measurements VT = -111.823 +- 9.290 uVs I1X = 22.365 +- 1.859 uTm 21:41:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:41:58 Integrated Voltage Measurement... 21:42:07 Voltage Offset Correction: v_off_ini = 599.735 uV, v_off_fin = 592.655 uV 21:42:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.538 uVs 21:42:07 Integrated Voltage Measurement... 21:42:16 Voltage Offset Correction: v_off_ini = 603.572 uV, v_off_fin = 613.987 uV 21:42:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.173 uVs 21:42:16 Integrated Voltage Measurement... 21:42:25 Voltage Offset Correction: v_off_ini = 594.193 uV, v_off_fin = 591.570 uV 21:42:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.593 uVs 21:42:25 Integrated Voltage Measurement... 21:42:34 Voltage Offset Correction: v_off_ini = 605.726 uV, v_off_fin = 615.526 uV 21:42:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.633 uVs 21:42:34 Integrated Voltage Measurement... 21:42:43 Voltage Offset Correction: v_off_ini = 598.183 uV, v_off_fin = 589.973 uV 21:42:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.178 uVs 21:42:43 Integrated Voltage Measurement... 21:42:52 Voltage Offset Correction: v_off_ini = 602.443 uV, v_off_fin = 616.268 uV 21:42:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.555 uVs 21:42:56 I1Y Average and RMS of Measurements VT = -194.278 +- 4.405 uVs I1Y = -38.856 +- 0.881 uTm 21:42:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:43:01 Integrated Voltage Measurement... 21:43:10 Voltage Offset Correction: v_off_ini = 582.259 uV, v_off_fin = 591.064 uV 21:43:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.723 uVs 21:43:10 Integrated Voltage Measurement... 21:43:19 Voltage Offset Correction: v_off_ini = 591.733 uV, v_off_fin = 595.769 uV 21:43:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.911 uVs 21:43:19 Integrated Voltage Measurement... 21:43:28 Voltage Offset Correction: v_off_ini = 584.488 uV, v_off_fin = 579.851 uV 21:43:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.562 uVs 21:43:28 Integrated Voltage Measurement... 21:43:37 Voltage Offset Correction: v_off_ini = 585.389 uV, v_off_fin = 599.888 uV 21:43:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.275 uVs 21:43:37 Integrated Voltage Measurement... 21:43:46 Voltage Offset Correction: v_off_ini = 593.646 uV, v_off_fin = 569.599 uV 21:43:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.158 uVs 21:43:46 Integrated Voltage Measurement... 21:43:55 Voltage Offset Correction: v_off_ini = 583.784 uV, v_off_fin = 596.570 uV 21:43:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.865 uVs 21:43:58 I2X Average and RMS of Measurements VT = -90.082 +- 2.727 uVs I2X = 8.288 +- 0.251 uTm^2 21:44:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 21:44:03 Integrated Voltage Measurement... 21:44:12 Voltage Offset Correction: v_off_ini = 600.367 uV, v_off_fin = 594.634 uV 21:44:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.560 uVs 21:44:12 Integrated Voltage Measurement... 21:44:21 Voltage Offset Correction: v_off_ini = 607.188 uV, v_off_fin = 602.747 uV 21:44:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 428.036 uVs 21:44:21 Integrated Voltage Measurement... 21:44:30 Voltage Offset Correction: v_off_ini = 593.400 uV, v_off_fin = 595.940 uV 21:44:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.013 uVs 21:44:30 Integrated Voltage Measurement... 21:44:39 Voltage Offset Correction: v_off_ini = 594.351 uV, v_off_fin = 597.826 uV 21:44:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 444.976 uVs 21:44:39 Integrated Voltage Measurement... 21:44:48 Voltage Offset Correction: v_off_ini = 598.394 uV, v_off_fin = 601.405 uV 21:44:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.310 uVs 21:44:48 Integrated Voltage Measurement... 21:44:57 Voltage Offset Correction: v_off_ini = 593.056 uV, v_off_fin = 602.886 uV 21:44:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 447.957 uVs 21:45:00 I2Y Average and RMS of Measurements VT = -440.475 +- 5.294 uVs I2Y = -40.524 +- 0.486 uTm^2 21:45:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:45:08 Integrated Voltage Measurement... 21:45:17 Voltage Offset Correction: v_off_ini = 604.061 uV, v_off_fin = 613.398 uV 21:45:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -89.511 uVs 21:45:17 Integrated Voltage Measurement... 21:45:26 Voltage Offset Correction: v_off_ini = 622.495 uV, v_off_fin = 605.823 uV 21:45:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.166 uVs 21:45:26 Integrated Voltage Measurement... 21:45:35 Voltage Offset Correction: v_off_ini = 625.909 uV, v_off_fin = 612.051 uV 21:45:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.196 uVs 21:45:35 Integrated Voltage Measurement... 21:45:44 Voltage Offset Correction: v_off_ini = 628.407 uV, v_off_fin = 622.828 uV 21:45:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.323 uVs 21:45:44 Integrated Voltage Measurement... 21:45:53 Voltage Offset Correction: v_off_ini = 617.454 uV, v_off_fin = 624.254 uV 21:45:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.045 uVs 21:45:53 Integrated Voltage Measurement... 21:46:02 Voltage Offset Correction: v_off_ini = 628.332 uV, v_off_fin = 634.053 uV 21:46:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.049 uVs 21:46:06 I1X Average and RMS of Measurements VT = -103.215 +- 6.162 uVs I1X = 20.644 +- 1.232 uTm 21:46:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:46:13 Integrated Voltage Measurement... 21:46:22 Voltage Offset Correction: v_off_ini = 626.350 uV, v_off_fin = 610.350 uV 21:46:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.066 uVs 21:46:22 Integrated Voltage Measurement... 21:46:31 Voltage Offset Correction: v_off_ini = 626.732 uV, v_off_fin = 637.611 uV 21:46:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.113 uVs 21:46:31 Integrated Voltage Measurement... 21:46:40 Voltage Offset Correction: v_off_ini = 632.416 uV, v_off_fin = 626.410 uV 21:46:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.269 uVs 21:46:40 Integrated Voltage Measurement... 21:46:49 Voltage Offset Correction: v_off_ini = 626.116 uV, v_off_fin = 645.390 uV 21:46:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.732 uVs 21:46:49 Integrated Voltage Measurement... 21:46:58 Voltage Offset Correction: v_off_ini = 639.491 uV, v_off_fin = 642.459 uV 21:46:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.117 uVs 21:46:58 Integrated Voltage Measurement... 21:47:07 Voltage Offset Correction: v_off_ini = 635.872 uV, v_off_fin = 647.719 uV 21:47:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.055 uVs 21:47:11 I1Y Average and RMS of Measurements VT = -192.892 +- 5.509 uVs I1Y = -38.576 +- 1.104 uTm 21:47:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:47:16 Integrated Voltage Measurement... 21:47:25 Voltage Offset Correction: v_off_ini = 633.681 uV, v_off_fin = 630.321 uV 21:47:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.177 uVs 21:47:25 Integrated Voltage Measurement... 21:47:34 Voltage Offset Correction: v_off_ini = 646.098 uV, v_off_fin = 651.735 uV 21:47:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.005 uVs 21:47:34 Integrated Voltage Measurement... 21:47:43 Voltage Offset Correction: v_off_ini = 643.285 uV, v_off_fin = 633.634 uV 21:47:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.468 uVs 21:47:44 Integrated Voltage Measurement... 21:47:52 Voltage Offset Correction: v_off_ini = 646.881 uV, v_off_fin = 649.190 uV 21:47:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.549 uVs 21:47:53 Integrated Voltage Measurement... 21:48:02 Voltage Offset Correction: v_off_ini = 645.887 uV, v_off_fin = 629.817 uV 21:48:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.968 uVs 21:48:02 Integrated Voltage Measurement... 21:48:11 Voltage Offset Correction: v_off_ini = 644.744 uV, v_off_fin = 643.536 uV 21:48:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.382 uVs 21:48:13 I2X Average and RMS of Measurements VT = -92.592 +- 10.323 uVs I2X = 8.518 +- 0.950 uTm^2 21:48:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:48:18 Integrated Voltage Measurement... 21:48:27 Voltage Offset Correction: v_off_ini = 645.125 uV, v_off_fin = 638.382 uV 21:48:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.768 uVs 21:48:27 Integrated Voltage Measurement... 21:48:36 Voltage Offset Correction: v_off_ini = 645.977 uV, v_off_fin = 645.643 uV 21:48:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.057 uVs 21:48:36 Integrated Voltage Measurement... 21:48:45 Voltage Offset Correction: v_off_ini = 640.533 uV, v_off_fin = 646.396 uV 21:48:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.042 uVs 21:48:45 Integrated Voltage Measurement... 21:48:54 Voltage Offset Correction: v_off_ini = 635.325 uV, v_off_fin = 633.239 uV 21:48:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 425.693 uVs 21:48:54 Integrated Voltage Measurement... 21:49:03 Voltage Offset Correction: v_off_ini = 631.884 uV, v_off_fin = 626.239 uV 21:49:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -454.356 uVs 21:49:03 Integrated Voltage Measurement... 21:49:12 Voltage Offset Correction: v_off_ini = 634.759 uV, v_off_fin = 626.981 uV 21:49:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.977 uVs 21:49:15 I2Y Average and RMS of Measurements VT = -442.149 +- 5.502 uVs I2Y = -40.678 +- 0.506 uTm^2 21:49:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:49:23 Integrated Voltage Measurement... 21:49:32 Voltage Offset Correction: v_off_ini = 654.690 uV, v_off_fin = 635.326 uV 21:49:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.563 uVs 21:49:32 Integrated Voltage Measurement... 21:49:41 Voltage Offset Correction: v_off_ini = 637.295 uV, v_off_fin = 640.035 uV 21:49:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.586 uVs 21:49:41 Integrated Voltage Measurement... 21:49:50 Voltage Offset Correction: v_off_ini = 643.773 uV, v_off_fin = 631.121 uV 21:49:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.720 uVs 21:49:50 Integrated Voltage Measurement... 21:49:59 Voltage Offset Correction: v_off_ini = 634.980 uV, v_off_fin = 638.291 uV 21:49:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.062 uVs 21:49:59 Integrated Voltage Measurement... 21:50:08 Voltage Offset Correction: v_off_ini = 639.004 uV, v_off_fin = 635.961 uV 21:50:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.324 uVs 21:50:08 Integrated Voltage Measurement... 21:50:17 Voltage Offset Correction: v_off_ini = 626.235 uV, v_off_fin = 634.936 uV 21:50:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.121 uVs 21:50:22 I1X Average and RMS of Measurements VT = -92.563 +- 2.066 uVs I1X = 18.513 +- 0.413 uTm 21:50:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:50:28 Integrated Voltage Measurement... 21:50:37 Voltage Offset Correction: v_off_ini = 640.714 uV, v_off_fin = 625.600 uV 21:50:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.711 uVs 21:50:37 Integrated Voltage Measurement... 21:50:46 Voltage Offset Correction: v_off_ini = 631.668 uV, v_off_fin = 655.571 uV 21:50:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.765 uVs 21:50:46 Integrated Voltage Measurement... 21:50:55 Voltage Offset Correction: v_off_ini = 636.835 uV, v_off_fin = 622.161 uV 21:50:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.691 uVs 21:50:55 Integrated Voltage Measurement... 21:51:04 Voltage Offset Correction: v_off_ini = 644.089 uV, v_off_fin = 637.984 uV 21:51:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.360 uVs 21:51:04 Integrated Voltage Measurement... 21:51:13 Voltage Offset Correction: v_off_ini = 637.137 uV, v_off_fin = 624.716 uV 21:51:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.847 uVs 21:51:13 Integrated Voltage Measurement... 21:51:22 Voltage Offset Correction: v_off_ini = 622.665 uV, v_off_fin = 637.756 uV 21:51:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 194.144 uVs 21:51:27 I1Y Average and RMS of Measurements VT = -195.086 +- 4.383 uVs I1Y = -39.013 +- 0.876 uTm 21:51:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:51:32 Integrated Voltage Measurement... 21:51:41 Voltage Offset Correction: v_off_ini = 612.448 uV, v_off_fin = 604.100 uV 21:51:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.019 uVs 21:51:41 Integrated Voltage Measurement... 21:51:50 Voltage Offset Correction: v_off_ini = 625.585 uV, v_off_fin = 635.634 uV 21:51:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.870 uVs 21:51:50 Integrated Voltage Measurement... 21:51:59 Voltage Offset Correction: v_off_ini = 630.346 uV, v_off_fin = 624.030 uV 21:51:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.564 uVs 21:51:59 Integrated Voltage Measurement... 21:52:08 Voltage Offset Correction: v_off_ini = 645.872 uV, v_off_fin = 647.986 uV 21:52:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.232 uVs 21:52:08 Integrated Voltage Measurement... 21:52:17 Voltage Offset Correction: v_off_ini = 651.295 uV, v_off_fin = 635.178 uV 21:52:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -69.985 uVs 21:52:17 Integrated Voltage Measurement... 21:52:26 Voltage Offset Correction: v_off_ini = 646.087 uV, v_off_fin = 655.113 uV 21:52:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 85.466 uVs 21:52:28 I2X Average and RMS of Measurements VT = -78.023 +- 1.868 uVs I2X = 7.178 +- 0.172 uTm^2 21:52:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:52:33 Integrated Voltage Measurement... 21:52:42 Voltage Offset Correction: v_off_ini = 634.579 uV, v_off_fin = 630.483 uV 21:52:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.391 uVs 21:52:43 Integrated Voltage Measurement... 21:52:52 Voltage Offset Correction: v_off_ini = 641.909 uV, v_off_fin = 652.700 uV 21:52:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 434.617 uVs 21:52:52 Integrated Voltage Measurement... 21:53:01 Voltage Offset Correction: v_off_ini = 651.502 uV, v_off_fin = 641.602 uV 21:53:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -436.623 uVs 21:53:01 Integrated Voltage Measurement... 21:53:10 Voltage Offset Correction: v_off_ini = 633.847 uV, v_off_fin = 639.776 uV 21:53:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.195 uVs 21:53:10 Integrated Voltage Measurement... 21:53:19 Voltage Offset Correction: v_off_ini = 638.776 uV, v_off_fin = 643.656 uV 21:53:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.059 uVs 21:53:19 Integrated Voltage Measurement... 21:53:28 Voltage Offset Correction: v_off_ini = 644.997 uV, v_off_fin = 640.265 uV 21:53:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 447.562 uVs 21:53:30 I2Y Average and RMS of Measurements VT = -442.741 +- 6.255 uVs I2Y = -40.732 +- 0.576 uTm^2 21:54:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:54:06 Integrated Voltage Measurement... 21:54:15 Voltage Offset Correction: v_off_ini = 645.733 uV, v_off_fin = 636.742 uV 21:54:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.302 uVs 21:54:15 Integrated Voltage Measurement... 21:54:24 Voltage Offset Correction: v_off_ini = 635.911 uV, v_off_fin = 634.134 uV 21:54:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.600 uVs 21:54:24 Integrated Voltage Measurement... 21:54:33 Voltage Offset Correction: v_off_ini = 639.878 uV, v_off_fin = 629.400 uV 21:54:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.575 uVs 21:54:33 Integrated Voltage Measurement... 21:54:42 Voltage Offset Correction: v_off_ini = 646.723 uV, v_off_fin = 639.308 uV 21:54:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.361 uVs 21:54:42 Integrated Voltage Measurement... 21:54:51 Voltage Offset Correction: v_off_ini = 636.190 uV, v_off_fin = 630.961 uV 21:54:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.242 uVs 21:54:51 Integrated Voltage Measurement... 21:55:00 Voltage Offset Correction: v_off_ini = 638.915 uV, v_off_fin = 643.145 uV 21:55:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.545 uVs 21:55:04 I1X Average and RMS of Measurements VT = -92.104 +- 10.500 uVs I1X = 18.421 +- 2.100 uTm 21:55:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:55:11 Integrated Voltage Measurement... 21:55:20 Voltage Offset Correction: v_off_ini = 645.434 uV, v_off_fin = 622.590 uV 21:55:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.597 uVs 21:55:20 Integrated Voltage Measurement... 21:55:29 Voltage Offset Correction: v_off_ini = 633.442 uV, v_off_fin = 647.928 uV 21:55:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.155 uVs 21:55:29 Integrated Voltage Measurement... 21:55:38 Voltage Offset Correction: v_off_ini = 627.907 uV, v_off_fin = 618.271 uV 21:55:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.663 uVs 21:55:38 Integrated Voltage Measurement... 21:55:47 Voltage Offset Correction: v_off_ini = 627.777 uV, v_off_fin = 639.582 uV 21:55:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.176 uVs 21:55:47 Integrated Voltage Measurement... 21:55:56 Voltage Offset Correction: v_off_ini = 620.090 uV, v_off_fin = 611.900 uV 21:55:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.920 uVs 21:55:56 Integrated Voltage Measurement... 21:56:05 Voltage Offset Correction: v_off_ini = 621.684 uV, v_off_fin = 613.408 uV 21:56:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.364 uVs 21:56:09 I1Y Average and RMS of Measurements VT = -191.979 +- 6.294 uVs I1Y = -38.396 +- 1.259 uTm 21:56:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:56:17 Integrated Voltage Measurement... 21:56:26 Voltage Offset Correction: v_off_ini = 619.556 uV, v_off_fin = 614.013 uV 21:56:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.178 uVs 21:56:26 Integrated Voltage Measurement... 21:56:35 Voltage Offset Correction: v_off_ini = 608.735 uV, v_off_fin = 624.495 uV 21:56:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.825 uVs 21:56:35 Integrated Voltage Measurement... 21:56:44 Voltage Offset Correction: v_off_ini = 615.937 uV, v_off_fin = 607.394 uV 21:56:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.256 uVs 21:56:44 Integrated Voltage Measurement... 21:56:53 Voltage Offset Correction: v_off_ini = 619.634 uV, v_off_fin = 626.139 uV 21:56:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.279 uVs 21:56:53 Integrated Voltage Measurement... 21:57:02 Voltage Offset Correction: v_off_ini = 617.288 uV, v_off_fin = 604.719 uV 21:57:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.574 uVs 21:57:02 Integrated Voltage Measurement... 21:57:11 Voltage Offset Correction: v_off_ini = 629.847 uV, v_off_fin = 634.761 uV 21:57:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.999 uVs 21:57:14 I2X Average and RMS of Measurements VT = -88.685 +- 4.316 uVs I2X = 8.159 +- 0.397 uTm^2 21:57:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 21:57:21 Integrated Voltage Measurement... 21:57:30 Voltage Offset Correction: v_off_ini = 643.072 uV, v_off_fin = 644.488 uV 21:57:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -306.757 uVs 21:57:30 Integrated Voltage Measurement... 21:57:39 Voltage Offset Correction: v_off_ini = 633.176 uV, v_off_fin = 625.995 uV 21:57:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.746 uVs 21:57:39 Integrated Voltage Measurement... 21:57:48 Voltage Offset Correction: v_off_ini = 620.222 uV, v_off_fin = 623.145 uV 21:57:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.875 uVs 21:57:48 Integrated Voltage Measurement... 21:57:57 Voltage Offset Correction: v_off_ini = 626.323 uV, v_off_fin = 633.067 uV 21:57:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.881 uVs 21:57:57 Integrated Voltage Measurement... 21:58:06 Voltage Offset Correction: v_off_ini = 629.284 uV, v_off_fin = 629.901 uV 21:58:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.748 uVs 21:58:07 Integrated Voltage Measurement... 21:58:16 Voltage Offset Correction: v_off_ini = 641.734 uV, v_off_fin = 633.203 uV 21:58:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.347 uVs 21:58:18 I2Y Average and RMS of Measurements VT = -303.392 +- 2.247 uVs I2Y = -27.913 +- 0.206 uTm^2 21:58:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:58:27 Integrated Voltage Measurement... 21:58:36 Voltage Offset Correction: v_off_ini = 627.508 uV, v_off_fin = 629.438 uV 21:58:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -98.754 uVs 21:58:36 Integrated Voltage Measurement... 21:58:45 Voltage Offset Correction: v_off_ini = 632.649 uV, v_off_fin = 618.855 uV 21:58:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.815 uVs 21:58:45 Integrated Voltage Measurement... 21:58:54 Voltage Offset Correction: v_off_ini = 633.997 uV, v_off_fin = 616.963 uV 21:58:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.839 uVs 21:58:54 Integrated Voltage Measurement... 21:59:03 Voltage Offset Correction: v_off_ini = 622.328 uV, v_off_fin = 616.933 uV 21:59:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.057 uVs 21:59:03 Integrated Voltage Measurement... 21:59:12 Voltage Offset Correction: v_off_ini = 622.234 uV, v_off_fin = 617.693 uV 21:59:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.903 uVs 21:59:12 Integrated Voltage Measurement... 21:59:21 Voltage Offset Correction: v_off_ini = 623.286 uV, v_off_fin = 629.419 uV 21:59:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.642 uVs 21:59:25 I1X Average and RMS of Measurements VT = -91.335 +- 5.613 uVs I1X = 18.268 +- 1.122 uTm 21:59:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 21:59:32 Integrated Voltage Measurement... 21:59:41 Voltage Offset Correction: v_off_ini = 631.218 uV, v_off_fin = 613.622 uV 21:59:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.925 uVs 21:59:41 Integrated Voltage Measurement... 21:59:50 Voltage Offset Correction: v_off_ini = 633.732 uV, v_off_fin = 635.541 uV 21:59:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.083 uVs 21:59:50 Integrated Voltage Measurement... 21:59:59 Voltage Offset Correction: v_off_ini = 628.460 uV, v_off_fin = 621.281 uV 21:59:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.747 uVs 21:59:59 Integrated Voltage Measurement... 22:00:08 Voltage Offset Correction: v_off_ini = 610.668 uV, v_off_fin = 621.232 uV 22:00:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.455 uVs 22:00:08 Integrated Voltage Measurement... 22:00:17 Voltage Offset Correction: v_off_ini = 622.360 uV, v_off_fin = 613.159 uV 22:00:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.289 uVs 22:00:17 Integrated Voltage Measurement... 22:00:26 Voltage Offset Correction: v_off_ini = 616.889 uV, v_off_fin = 622.899 uV 22:00:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.417 uVs 22:00:30 I1Y Average and RMS of Measurements VT = -200.986 +- 2.820 uVs I1Y = -40.197 +- 0.564 uTm 22:00:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:00:38 Integrated Voltage Measurement... 22:00:47 Voltage Offset Correction: v_off_ini = 609.697 uV, v_off_fin = 617.317 uV 22:00:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.559 uVs 22:00:47 Integrated Voltage Measurement... 22:00:56 Voltage Offset Correction: v_off_ini = 608.364 uV, v_off_fin = 628.484 uV 22:00:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.353 uVs 22:00:56 Integrated Voltage Measurement... 22:01:05 Voltage Offset Correction: v_off_ini = 627.972 uV, v_off_fin = 616.286 uV 22:01:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.547 uVs 22:01:05 Integrated Voltage Measurement... 22:01:14 Voltage Offset Correction: v_off_ini = 617.703 uV, v_off_fin = 634.012 uV 22:01:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.299 uVs 22:01:14 Integrated Voltage Measurement... 22:01:23 Voltage Offset Correction: v_off_ini = 626.012 uV, v_off_fin = 620.631 uV 22:01:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.971 uVs 22:01:23 Integrated Voltage Measurement... 22:01:32 Voltage Offset Correction: v_off_ini = 611.741 uV, v_off_fin = 626.073 uV 22:01:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.721 uVs 22:01:35 I2X Average and RMS of Measurements VT = -88.741 +- 4.003 uVs I2X = 8.164 +- 0.368 uTm^2 22:01:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 22:01:42 Integrated Voltage Measurement... 22:01:51 Voltage Offset Correction: v_off_ini = 606.737 uV, v_off_fin = 608.998 uV 22:01:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.715 uVs 22:01:51 Integrated Voltage Measurement... 22:02:00 Voltage Offset Correction: v_off_ini = 609.449 uV, v_off_fin = 614.938 uV 22:02:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.406 uVs 22:02:00 Integrated Voltage Measurement... 22:02:09 Voltage Offset Correction: v_off_ini = 614.020 uV, v_off_fin = 618.480 uV 22:02:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.796 uVs 22:02:10 Integrated Voltage Measurement... 22:02:19 Voltage Offset Correction: v_off_ini = 626.681 uV, v_off_fin = 634.803 uV 22:02:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.237 uVs 22:02:19 Integrated Voltage Measurement... 22:02:28 Voltage Offset Correction: v_off_ini = 616.026 uV, v_off_fin = 617.693 uV 22:02:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.478 uVs 22:02:28 Integrated Voltage Measurement... 22:02:37 Voltage Offset Correction: v_off_ini = 613.263 uV, v_off_fin = 622.000 uV 22:02:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.670 uVs 22:02:39 I2Y Average and RMS of Measurements VT = -305.384 +- 9.421 uVs I2Y = -28.095 +- 0.867 uTm^2 22:02:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:02:48 Integrated Voltage Measurement... 22:02:57 Voltage Offset Correction: v_off_ini = 617.256 uV, v_off_fin = 608.916 uV 22:02:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.371 uVs 22:02:57 Integrated Voltage Measurement... 22:03:06 Voltage Offset Correction: v_off_ini = 620.180 uV, v_off_fin = 634.925 uV 22:03:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.449 uVs 22:03:06 Integrated Voltage Measurement... 22:03:15 Voltage Offset Correction: v_off_ini = 619.034 uV, v_off_fin = 615.762 uV 22:03:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -113.023 uVs 22:03:15 Integrated Voltage Measurement... 22:03:24 Voltage Offset Correction: v_off_ini = 611.100 uV, v_off_fin = 615.502 uV 22:03:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 78.929 uVs 22:03:24 Integrated Voltage Measurement... 22:03:33 Voltage Offset Correction: v_off_ini = 610.138 uV, v_off_fin = 604.665 uV 22:03:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.352 uVs 22:03:33 Integrated Voltage Measurement... 22:03:42 Voltage Offset Correction: v_off_ini = 600.423 uV, v_off_fin = 604.291 uV 22:03:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.697 uVs 22:03:46 I1X Average and RMS of Measurements VT = -99.970 +- 3.512 uVs I1X = 19.995 +- 0.702 uTm 22:03:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:03:53 Integrated Voltage Measurement... 22:04:02 Voltage Offset Correction: v_off_ini = 607.255 uV, v_off_fin = 598.639 uV 22:04:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -190.616 uVs 22:04:02 Integrated Voltage Measurement... 22:04:11 Voltage Offset Correction: v_off_ini = 617.818 uV, v_off_fin = 618.443 uV 22:04:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.618 uVs 22:04:11 Integrated Voltage Measurement... 22:04:20 Voltage Offset Correction: v_off_ini = 608.951 uV, v_off_fin = 593.346 uV 22:04:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.572 uVs 22:04:20 Integrated Voltage Measurement... 22:04:29 Voltage Offset Correction: v_off_ini = 611.571 uV, v_off_fin = 606.835 uV 22:04:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.000 uVs 22:04:29 Integrated Voltage Measurement... 22:04:38 Voltage Offset Correction: v_off_ini = 612.543 uV, v_off_fin = 599.075 uV 22:04:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.161 uVs 22:04:38 Integrated Voltage Measurement... 22:04:47 Voltage Offset Correction: v_off_ini = 607.616 uV, v_off_fin = 614.558 uV 22:04:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.633 uVs 22:04:51 I1Y Average and RMS of Measurements VT = -193.600 +- 3.285 uVs I1Y = -38.721 +- 0.655 uTm 22:04:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:04:59 Integrated Voltage Measurement... 22:05:08 Voltage Offset Correction: v_off_ini = 615.695 uV, v_off_fin = 612.601 uV 22:05:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -80.856 uVs 22:05:08 Integrated Voltage Measurement... 22:05:17 Voltage Offset Correction: v_off_ini = 621.294 uV, v_off_fin = 620.474 uV 22:05:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.982 uVs 22:05:17 Integrated Voltage Measurement... 22:05:26 Voltage Offset Correction: v_off_ini = 609.450 uV, v_off_fin = 602.561 uV 22:05:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.928 uVs 22:05:26 Integrated Voltage Measurement... 22:05:35 Voltage Offset Correction: v_off_ini = 608.878 uV, v_off_fin = 616.340 uV 22:05:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.644 uVs 22:05:35 Integrated Voltage Measurement... 22:05:44 Voltage Offset Correction: v_off_ini = 610.213 uV, v_off_fin = 603.521 uV 22:05:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.185 uVs 22:05:44 Integrated Voltage Measurement... 22:05:53 Voltage Offset Correction: v_off_ini = 618.404 uV, v_off_fin = 623.299 uV 22:05:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.395 uVs 22:05:56 I2X Average and RMS of Measurements VT = -92.498 +- 6.465 uVs I2X = 8.510 +- 0.595 uTm^2 22:06:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:06:03 Integrated Voltage Measurement... 22:06:12 Voltage Offset Correction: v_off_ini = 609.985 uV, v_off_fin = 609.621 uV 22:06:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.588 uVs 22:06:13 Integrated Voltage Measurement... 22:06:22 Voltage Offset Correction: v_off_ini = 613.430 uV, v_off_fin = 605.070 uV 22:06:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.337 uVs 22:06:22 Integrated Voltage Measurement... 22:06:31 Voltage Offset Correction: v_off_ini = 592.117 uV, v_off_fin = 607.797 uV 22:06:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.748 uVs 22:06:31 Integrated Voltage Measurement... 22:06:40 Voltage Offset Correction: v_off_ini = 599.894 uV, v_off_fin = 608.451 uV 22:06:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.756 uVs 22:06:40 Integrated Voltage Measurement... 22:06:49 Voltage Offset Correction: v_off_ini = 613.284 uV, v_off_fin = 611.345 uV 22:06:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.382 uVs 22:06:49 Integrated Voltage Measurement... 22:06:58 Voltage Offset Correction: v_off_ini = 611.194 uV, v_off_fin = 605.265 uV 22:06:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.046 uVs 22:07:00 I2Y Average and RMS of Measurements VT = -314.476 +- 7.411 uVs I2Y = -28.932 +- 0.682 uTm^2 22:07:05 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:07:09 Integrated Voltage Measurement... 22:07:18 Voltage Offset Correction: v_off_ini = 616.467 uV, v_off_fin = 613.896 uV 22:07:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.259 uVs 22:07:18 Integrated Voltage Measurement... 22:07:27 Voltage Offset Correction: v_off_ini = 615.128 uV, v_off_fin = 607.736 uV 22:07:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.966 uVs 22:07:27 Integrated Voltage Measurement... 22:07:36 Voltage Offset Correction: v_off_ini = 619.853 uV, v_off_fin = 621.955 uV 22:07:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.941 uVs 22:07:36 Integrated Voltage Measurement... 22:07:45 Voltage Offset Correction: v_off_ini = 631.386 uV, v_off_fin = 631.507 uV 22:07:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.732 uVs 22:07:45 Integrated Voltage Measurement... 22:07:54 Voltage Offset Correction: v_off_ini = 629.701 uV, v_off_fin = 614.950 uV 22:07:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.507 uVs 22:07:54 Integrated Voltage Measurement... 22:08:03 Voltage Offset Correction: v_off_ini = 614.990 uV, v_off_fin = 615.001 uV 22:08:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.618 uVs 22:08:07 I1X Average and RMS of Measurements VT = -91.837 +- 6.647 uVs I1X = 18.368 +- 1.330 uTm 22:08:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:08:14 Integrated Voltage Measurement... 22:08:23 Voltage Offset Correction: v_off_ini = 616.001 uV, v_off_fin = 618.029 uV 22:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.177 uVs 22:08:23 Integrated Voltage Measurement... 22:08:32 Voltage Offset Correction: v_off_ini = 625.560 uV, v_off_fin = 631.385 uV 22:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.371 uVs 22:08:32 Integrated Voltage Measurement... 22:08:41 Voltage Offset Correction: v_off_ini = 634.301 uV, v_off_fin = 622.705 uV 22:08:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.677 uVs 22:08:41 Integrated Voltage Measurement... 22:08:50 Voltage Offset Correction: v_off_ini = 614.725 uV, v_off_fin = 621.486 uV 22:08:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.121 uVs 22:08:50 Integrated Voltage Measurement... 22:08:59 Voltage Offset Correction: v_off_ini = 616.159 uV, v_off_fin = 594.193 uV 22:08:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.457 uVs 22:08:59 Integrated Voltage Measurement... 22:09:08 Voltage Offset Correction: v_off_ini = 614.054 uV, v_off_fin = 611.309 uV 22:09:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.599 uVs 22:09:12 I1Y Average and RMS of Measurements VT = -205.234 +- 3.747 uVs I1Y = -41.047 +- 0.749 uTm 22:09:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:09:20 Integrated Voltage Measurement... 22:09:29 Voltage Offset Correction: v_off_ini = 608.129 uV, v_off_fin = 613.961 uV 22:09:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -84.150 uVs 22:09:29 Integrated Voltage Measurement... 22:09:38 Voltage Offset Correction: v_off_ini = 621.083 uV, v_off_fin = 633.306 uV 22:09:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.635 uVs 22:09:38 Integrated Voltage Measurement... 22:09:47 Voltage Offset Correction: v_off_ini = 613.679 uV, v_off_fin = 593.025 uV 22:09:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.967 uVs 22:09:47 Integrated Voltage Measurement... 22:09:56 Voltage Offset Correction: v_off_ini = 596.168 uV, v_off_fin = 616.685 uV 22:09:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.959 uVs 22:09:56 Integrated Voltage Measurement... 22:10:05 Voltage Offset Correction: v_off_ini = 614.093 uV, v_off_fin = 596.630 uV 22:10:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.525 uVs 22:10:05 Integrated Voltage Measurement... 22:10:14 Voltage Offset Correction: v_off_ini = 606.258 uV, v_off_fin = 613.305 uV 22:10:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.528 uVs 22:10:17 I2X Average and RMS of Measurements VT = -92.294 +- 3.471 uVs I2X = 8.491 +- 0.320 uTm^2 22:10:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 22:10:24 Integrated Voltage Measurement... 22:10:33 Voltage Offset Correction: v_off_ini = 606.843 uV, v_off_fin = 603.078 uV 22:10:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.426 uVs 22:10:33 Integrated Voltage Measurement... 22:10:42 Voltage Offset Correction: v_off_ini = 605.758 uV, v_off_fin = 607.107 uV 22:10:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.048 uVs 22:10:42 Integrated Voltage Measurement... 22:10:51 Voltage Offset Correction: v_off_ini = 590.826 uV, v_off_fin = 606.549 uV 22:10:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.210 uVs 22:10:51 Integrated Voltage Measurement... 22:11:00 Voltage Offset Correction: v_off_ini = 615.967 uV, v_off_fin = 618.827 uV 22:11:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.060 uVs 22:11:00 Integrated Voltage Measurement... 22:11:09 Voltage Offset Correction: v_off_ini = 618.600 uV, v_off_fin = 616.402 uV 22:11:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.345 uVs 22:11:09 Integrated Voltage Measurement... 22:11:18 Voltage Offset Correction: v_off_ini = 615.882 uV, v_off_fin = 616.942 uV 22:11:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.790 uVs 22:11:21 I2Y Average and RMS of Measurements VT = -308.313 +- 8.971 uVs I2Y = -28.365 +- 0.825 uTm^2 22:11:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:11:30 Integrated Voltage Measurement... 22:11:39 Voltage Offset Correction: v_off_ini = 627.163 uV, v_off_fin = 627.977 uV 22:11:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.353 uVs 22:11:39 Integrated Voltage Measurement... 22:11:48 Voltage Offset Correction: v_off_ini = 617.160 uV, v_off_fin = 622.027 uV 22:11:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 93.453 uVs 22:11:48 Integrated Voltage Measurement... 22:11:57 Voltage Offset Correction: v_off_ini = 619.652 uV, v_off_fin = 609.035 uV 22:11:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -87.761 uVs 22:11:57 Integrated Voltage Measurement... 22:12:06 Voltage Offset Correction: v_off_ini = 607.370 uV, v_off_fin = 610.008 uV 22:12:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 114.842 uVs 22:12:06 Integrated Voltage Measurement... 22:12:15 Voltage Offset Correction: v_off_ini = 624.578 uV, v_off_fin = 619.967 uV 22:12:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.886 uVs 22:12:15 Integrated Voltage Measurement... 22:12:24 Voltage Offset Correction: v_off_ini = 628.979 uV, v_off_fin = 628.868 uV 22:12:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.128 uVs 22:12:28 I1X Average and RMS of Measurements VT = -96.070 +- 3.797 uVs I1X = 19.216 +- 0.760 uTm 22:12:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:12:35 Integrated Voltage Measurement... 22:12:44 Voltage Offset Correction: v_off_ini = 644.019 uV, v_off_fin = 632.193 uV 22:12:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.175 uVs 22:12:44 Integrated Voltage Measurement... 22:12:53 Voltage Offset Correction: v_off_ini = 639.300 uV, v_off_fin = 644.488 uV 22:12:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.822 uVs 22:12:53 Integrated Voltage Measurement... 22:13:02 Voltage Offset Correction: v_off_ini = 639.114 uV, v_off_fin = 634.006 uV 22:13:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.916 uVs 22:13:02 Integrated Voltage Measurement... 22:13:11 Voltage Offset Correction: v_off_ini = 624.029 uV, v_off_fin = 641.473 uV 22:13:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.695 uVs 22:13:11 Integrated Voltage Measurement... 22:13:20 Voltage Offset Correction: v_off_ini = 638.756 uV, v_off_fin = 614.246 uV 22:13:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.882 uVs 22:13:20 Integrated Voltage Measurement... 22:13:29 Voltage Offset Correction: v_off_ini = 638.322 uV, v_off_fin = 643.207 uV 22:13:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.655 uVs 22:13:33 I1Y Average and RMS of Measurements VT = -200.857 +- 6.575 uVs I1Y = -40.171 +- 1.315 uTm 22:13:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:13:41 Integrated Voltage Measurement... 22:13:50 Voltage Offset Correction: v_off_ini = 637.212 uV, v_off_fin = 622.150 uV 22:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.394 uVs 22:13:50 Integrated Voltage Measurement... 22:13:59 Voltage Offset Correction: v_off_ini = 635.371 uV, v_off_fin = 640.319 uV 22:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.281 uVs 22:13:59 Integrated Voltage Measurement... 22:14:08 Voltage Offset Correction: v_off_ini = 623.027 uV, v_off_fin = 623.815 uV 22:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.514 uVs 22:14:08 Integrated Voltage Measurement... 22:14:17 Voltage Offset Correction: v_off_ini = 630.165 uV, v_off_fin = 635.346 uV 22:14:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.900 uVs 22:14:17 Integrated Voltage Measurement... 22:14:26 Voltage Offset Correction: v_off_ini = 635.926 uV, v_off_fin = 609.897 uV 22:14:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.784 uVs 22:14:26 Integrated Voltage Measurement... 22:14:35 Voltage Offset Correction: v_off_ini = 613.453 uV, v_off_fin = 627.141 uV 22:14:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.854 uVs 22:14:37 I2X Average and RMS of Measurements VT = -90.788 +- 8.926 uVs I2X = 8.352 +- 0.821 uTm^2 22:14:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 22:14:45 Integrated Voltage Measurement... 22:14:54 Voltage Offset Correction: v_off_ini = 632.666 uV, v_off_fin = 637.843 uV 22:14:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -303.736 uVs 22:14:54 Integrated Voltage Measurement... 22:15:03 Voltage Offset Correction: v_off_ini = 637.424 uV, v_off_fin = 633.276 uV 22:15:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 306.953 uVs 22:15:03 Integrated Voltage Measurement... 22:15:12 Voltage Offset Correction: v_off_ini = 639.649 uV, v_off_fin = 627.292 uV 22:15:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.050 uVs 22:15:12 Integrated Voltage Measurement... 22:15:21 Voltage Offset Correction: v_off_ini = 640.811 uV, v_off_fin = 645.963 uV 22:15:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.794 uVs 22:15:21 Integrated Voltage Measurement... 22:15:30 Voltage Offset Correction: v_off_ini = 646.760 uV, v_off_fin = 635.601 uV 22:15:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.499 uVs 22:15:30 Integrated Voltage Measurement... 22:15:39 Voltage Offset Correction: v_off_ini = 645.148 uV, v_off_fin = 627.023 uV 22:15:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.206 uVs 22:15:41 I2Y Average and RMS of Measurements VT = -308.206 +- 3.002 uVs I2Y = -28.356 +- 0.275 uTm^2 22:15:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:15:53 Integrated Voltage Measurement... 22:16:02 Voltage Offset Correction: v_off_ini = 630.747 uV, v_off_fin = 644.593 uV 22:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.774 uVs 22:16:02 Integrated Voltage Measurement... 22:16:11 Voltage Offset Correction: v_off_ini = 649.234 uV, v_off_fin = 642.452 uV 22:16:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.373 uVs 22:16:11 Integrated Voltage Measurement... 22:16:20 Voltage Offset Correction: v_off_ini = 643.287 uV, v_off_fin = 631.452 uV 22:16:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.832 uVs 22:16:20 Integrated Voltage Measurement... 22:16:29 Voltage Offset Correction: v_off_ini = 632.914 uV, v_off_fin = 641.064 uV 22:16:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.045 uVs 22:16:29 Integrated Voltage Measurement... 22:16:38 Voltage Offset Correction: v_off_ini = 637.557 uV, v_off_fin = 633.780 uV 22:16:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.986 uVs 22:16:38 Integrated Voltage Measurement... 22:16:47 Voltage Offset Correction: v_off_ini = 636.198 uV, v_off_fin = 627.750 uV 22:16:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.017 uVs 22:16:52 I1X Average and RMS of Measurements VT = -83.671 +- 7.946 uVs I1X = 16.734 +- 1.589 uTm 22:16:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:16:58 Integrated Voltage Measurement... 22:17:07 Voltage Offset Correction: v_off_ini = 632.232 uV, v_off_fin = 631.511 uV 22:17:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.683 uVs 22:17:07 Integrated Voltage Measurement... 22:17:16 Voltage Offset Correction: v_off_ini = 637.900 uV, v_off_fin = 652.616 uV 22:17:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.667 uVs 22:17:16 Integrated Voltage Measurement... 22:17:25 Voltage Offset Correction: v_off_ini = 632.465 uV, v_off_fin = 626.461 uV 22:17:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.715 uVs 22:17:25 Integrated Voltage Measurement... 22:17:34 Voltage Offset Correction: v_off_ini = 644.195 uV, v_off_fin = 641.972 uV 22:17:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.715 uVs 22:17:34 Integrated Voltage Measurement... 22:17:43 Voltage Offset Correction: v_off_ini = 628.876 uV, v_off_fin = 629.999 uV 22:17:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -192.963 uVs 22:17:43 Integrated Voltage Measurement... 22:17:52 Voltage Offset Correction: v_off_ini = 645.920 uV, v_off_fin = 647.191 uV 22:17:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.894 uVs 22:17:56 I1Y Average and RMS of Measurements VT = -194.606 +- 4.703 uVs I1Y = -38.922 +- 0.941 uTm 22:17:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:18:02 Integrated Voltage Measurement... 22:18:11 Voltage Offset Correction: v_off_ini = 642.917 uV, v_off_fin = 628.951 uV 22:18:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.300 uVs 22:18:11 Integrated Voltage Measurement... 22:18:20 Voltage Offset Correction: v_off_ini = 640.497 uV, v_off_fin = 637.486 uV 22:18:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.692 uVs 22:18:20 Integrated Voltage Measurement... 22:18:29 Voltage Offset Correction: v_off_ini = 640.355 uV, v_off_fin = 627.919 uV 22:18:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.977 uVs 22:18:29 Integrated Voltage Measurement... 22:18:38 Voltage Offset Correction: v_off_ini = 626.142 uV, v_off_fin = 634.540 uV 22:18:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.690 uVs 22:18:38 Integrated Voltage Measurement... 22:18:47 Voltage Offset Correction: v_off_ini = 618.778 uV, v_off_fin = 624.381 uV 22:18:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.387 uVs 22:18:47 Integrated Voltage Measurement... 22:18:56 Voltage Offset Correction: v_off_ini = 629.498 uV, v_off_fin = 649.390 uV 22:18:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.516 uVs 22:18:58 I2X Average and RMS of Measurements VT = -73.094 +- 4.060 uVs I2X = 6.725 +- 0.373 uTm^2 22:19:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 22:19:03 Integrated Voltage Measurement... 22:19:12 Voltage Offset Correction: v_off_ini = 629.596 uV, v_off_fin = 639.799 uV 22:19:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.673 uVs 22:19:12 Integrated Voltage Measurement... 22:19:21 Voltage Offset Correction: v_off_ini = 633.418 uV, v_off_fin = 635.945 uV 22:19:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.950 uVs 22:19:21 Integrated Voltage Measurement... 22:19:30 Voltage Offset Correction: v_off_ini = 641.557 uV, v_off_fin = 634.736 uV 22:19:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -303.566 uVs 22:19:30 Integrated Voltage Measurement... 22:19:39 Voltage Offset Correction: v_off_ini = 624.742 uV, v_off_fin = 632.699 uV 22:19:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.837 uVs 22:19:39 Integrated Voltage Measurement... 22:19:48 Voltage Offset Correction: v_off_ini = 625.755 uV, v_off_fin = 634.560 uV 22:19:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.710 uVs 22:19:48 Integrated Voltage Measurement... 22:19:57 Voltage Offset Correction: v_off_ini = 638.093 uV, v_off_fin = 632.331 uV 22:19:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.214 uVs 22:20:00 I2Y Average and RMS of Measurements VT = -299.991 +- 8.763 uVs I2Y = -27.600 +- 0.807 uTm^2 22:20:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:20:08 Integrated Voltage Measurement... 22:20:17 Voltage Offset Correction: v_off_ini = 644.188 uV, v_off_fin = 628.635 uV 22:20:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -97.356 uVs 22:20:17 Integrated Voltage Measurement... 22:20:26 Voltage Offset Correction: v_off_ini = 633.982 uV, v_off_fin = 634.773 uV 22:20:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.253 uVs 22:20:26 Integrated Voltage Measurement... 22:20:35 Voltage Offset Correction: v_off_ini = 631.574 uV, v_off_fin = 619.856 uV 22:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.328 uVs 22:20:35 Integrated Voltage Measurement... 22:20:44 Voltage Offset Correction: v_off_ini = 615.119 uV, v_off_fin = 619.463 uV 22:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.634 uVs 22:20:44 Integrated Voltage Measurement... 22:20:53 Voltage Offset Correction: v_off_ini = 634.244 uV, v_off_fin = 623.108 uV 22:20:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.927 uVs 22:20:53 Integrated Voltage Measurement... 22:21:02 Voltage Offset Correction: v_off_ini = 625.679 uV, v_off_fin = 630.510 uV 22:21:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 80.475 uVs 22:21:06 I1X Average and RMS of Measurements VT = -88.329 +- 1.009 uVs I1X = 17.667 +- 0.201 uTm 22:21:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:21:13 Integrated Voltage Measurement... 22:21:22 Voltage Offset Correction: v_off_ini = 625.253 uV, v_off_fin = 623.270 uV 22:21:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -181.489 uVs 22:21:22 Integrated Voltage Measurement... 22:21:31 Voltage Offset Correction: v_off_ini = 619.367 uV, v_off_fin = 633.813 uV 22:21:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.963 uVs 22:21:31 Integrated Voltage Measurement... 22:21:40 Voltage Offset Correction: v_off_ini = 620.143 uV, v_off_fin = 608.960 uV 22:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.191 uVs 22:21:40 Integrated Voltage Measurement... 22:21:49 Voltage Offset Correction: v_off_ini = 626.226 uV, v_off_fin = 626.864 uV 22:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.007 uVs 22:21:49 Integrated Voltage Measurement... 22:21:58 Voltage Offset Correction: v_off_ini = 618.981 uV, v_off_fin = 618.417 uV 22:21:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -215.854 uVs 22:21:58 Integrated Voltage Measurement... 22:22:07 Voltage Offset Correction: v_off_ini = 628.021 uV, v_off_fin = 631.702 uV 22:22:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.373 uVs 22:22:11 I1Y Average and RMS of Measurements VT = -194.479 +- 10.867 uVs I1Y = -38.898 +- 2.174 uTm 22:22:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:22:16 Integrated Voltage Measurement... 22:22:25 Voltage Offset Correction: v_off_ini = 622.312 uV, v_off_fin = 617.772 uV 22:22:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.985 uVs 22:22:26 Integrated Voltage Measurement... 22:22:35 Voltage Offset Correction: v_off_ini = 621.276 uV, v_off_fin = 648.445 uV 22:22:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.013 uVs 22:22:35 Integrated Voltage Measurement... 22:22:44 Voltage Offset Correction: v_off_ini = 623.275 uV, v_off_fin = 612.630 uV 22:22:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.402 uVs 22:22:44 Integrated Voltage Measurement... 22:22:53 Voltage Offset Correction: v_off_ini = 619.723 uV, v_off_fin = 623.335 uV 22:22:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.376 uVs 22:22:53 Integrated Voltage Measurement... 22:23:02 Voltage Offset Correction: v_off_ini = 620.609 uV, v_off_fin = 617.840 uV 22:23:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.097 uVs 22:23:02 Integrated Voltage Measurement... 22:23:11 Voltage Offset Correction: v_off_ini = 609.595 uV, v_off_fin = 629.881 uV 22:23:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.249 uVs 22:23:13 I2X Average and RMS of Measurements VT = -85.187 +- 6.857 uVs I2X = 7.837 +- 0.631 uTm^2 22:23:16 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 22:23:18 Integrated Voltage Measurement... 22:23:27 Voltage Offset Correction: v_off_ini = 637.491 uV, v_off_fin = 631.242 uV 22:23:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -285.812 uVs 22:23:27 Integrated Voltage Measurement... 22:23:36 Voltage Offset Correction: v_off_ini = 628.099 uV, v_off_fin = 629.118 uV 22:23:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.252 uVs 22:23:36 Integrated Voltage Measurement... 22:23:45 Voltage Offset Correction: v_off_ini = 632.114 uV, v_off_fin = 629.239 uV 22:23:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.540 uVs 22:23:45 Integrated Voltage Measurement... 22:23:54 Voltage Offset Correction: v_off_ini = 632.722 uV, v_off_fin = 621.725 uV 22:23:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.795 uVs 22:23:54 Integrated Voltage Measurement... 22:24:03 Voltage Offset Correction: v_off_ini = 624.044 uV, v_off_fin = 623.575 uV 22:24:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.411 uVs 22:24:04 Integrated Voltage Measurement... 22:24:13 Voltage Offset Correction: v_off_ini = 612.521 uV, v_off_fin = 617.799 uV 22:24:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.360 uVs 22:24:15 I2Y Average and RMS of Measurements VT = -309.861 +- 9.319 uVs I2Y = -28.508 +- 0.857 uTm^2 22:24:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:24:23 Integrated Voltage Measurement... 22:24:32 Voltage Offset Correction: v_off_ini = 629.636 uV, v_off_fin = 613.320 uV 22:24:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.113 uVs 22:24:32 Integrated Voltage Measurement... 22:24:41 Voltage Offset Correction: v_off_ini = 617.548 uV, v_off_fin = 630.855 uV 22:24:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.059 uVs 22:24:41 Integrated Voltage Measurement... 22:24:50 Voltage Offset Correction: v_off_ini = 632.576 uV, v_off_fin = 621.281 uV 22:24:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.138 uVs 22:24:50 Integrated Voltage Measurement... 22:24:59 Voltage Offset Correction: v_off_ini = 624.246 uV, v_off_fin = 615.858 uV 22:24:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.055 uVs 22:24:59 Integrated Voltage Measurement... 22:25:08 Voltage Offset Correction: v_off_ini = 620.475 uV, v_off_fin = 612.010 uV 22:25:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.002 uVs 22:25:08 Integrated Voltage Measurement... 22:25:17 Voltage Offset Correction: v_off_ini = 626.983 uV, v_off_fin = 624.779 uV 22:25:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.401 uVs 22:25:22 I1X Average and RMS of Measurements VT = -100.294 +- 2.819 uVs I1X = 20.059 +- 0.564 uTm 22:25:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:25:28 Integrated Voltage Measurement... 22:25:37 Voltage Offset Correction: v_off_ini = 626.767 uV, v_off_fin = 617.797 uV 22:25:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.592 uVs 22:25:37 Integrated Voltage Measurement... 22:25:46 Voltage Offset Correction: v_off_ini = 622.538 uV, v_off_fin = 627.770 uV 22:25:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.793 uVs 22:25:46 Integrated Voltage Measurement... 22:25:55 Voltage Offset Correction: v_off_ini = 622.082 uV, v_off_fin = 607.259 uV 22:25:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.020 uVs 22:25:55 Integrated Voltage Measurement... 22:26:04 Voltage Offset Correction: v_off_ini = 618.503 uV, v_off_fin = 626.586 uV 22:26:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.338 uVs 22:26:04 Integrated Voltage Measurement... 22:26:13 Voltage Offset Correction: v_off_ini = 618.644 uV, v_off_fin = 620.551 uV 22:26:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.266 uVs 22:26:13 Integrated Voltage Measurement... 22:26:22 Voltage Offset Correction: v_off_ini = 623.505 uV, v_off_fin = 626.972 uV 22:26:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.955 uVs 22:26:27 I1Y Average and RMS of Measurements VT = -195.827 +- 4.295 uVs I1Y = -39.164 +- 0.859 uTm 22:26:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:26:32 Integrated Voltage Measurement... 22:26:41 Voltage Offset Correction: v_off_ini = 605.309 uV, v_off_fin = 607.737 uV 22:26:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.767 uVs 22:26:41 Integrated Voltage Measurement... 22:26:50 Voltage Offset Correction: v_off_ini = 617.775 uV, v_off_fin = 630.466 uV 22:26:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.608 uVs 22:26:50 Integrated Voltage Measurement... 22:26:59 Voltage Offset Correction: v_off_ini = 624.305 uV, v_off_fin = 607.017 uV 22:26:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.614 uVs 22:26:59 Integrated Voltage Measurement... 22:27:08 Voltage Offset Correction: v_off_ini = 623.164 uV, v_off_fin = 635.151 uV 22:27:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.772 uVs 22:27:08 Integrated Voltage Measurement... 22:27:17 Voltage Offset Correction: v_off_ini = 616.066 uV, v_off_fin = 610.323 uV 22:27:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.727 uVs 22:27:17 Integrated Voltage Measurement... 22:27:26 Voltage Offset Correction: v_off_ini = 617.547 uV, v_off_fin = 624.150 uV 22:27:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.658 uVs 22:27:28 I2X Average and RMS of Measurements VT = -84.191 +- 5.353 uVs I2X = 7.746 +- 0.493 uTm^2 22:27:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 22:27:34 Integrated Voltage Measurement... 22:27:43 Voltage Offset Correction: v_off_ini = 604.801 uV, v_off_fin = 603.154 uV 22:27:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -309.581 uVs 22:27:43 Integrated Voltage Measurement... 22:27:52 Voltage Offset Correction: v_off_ini = 609.318 uV, v_off_fin = 607.876 uV 22:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.359 uVs 22:27:52 Integrated Voltage Measurement... 22:28:01 Voltage Offset Correction: v_off_ini = 604.394 uV, v_off_fin = 605.191 uV 22:28:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.969 uVs 22:28:01 Integrated Voltage Measurement... 22:28:10 Voltage Offset Correction: v_off_ini = 604.954 uV, v_off_fin = 608.777 uV 22:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.704 uVs 22:28:10 Integrated Voltage Measurement... 22:28:19 Voltage Offset Correction: v_off_ini = 607.118 uV, v_off_fin = 598.640 uV 22:28:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.564 uVs 22:28:19 Integrated Voltage Measurement... 22:28:28 Voltage Offset Correction: v_off_ini = 617.060 uV, v_off_fin = 606.090 uV 22:28:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.513 uVs 22:28:30 I2Y Average and RMS of Measurements VT = -315.115 +- 5.250 uVs I2Y = -28.991 +- 0.483 uTm^2 22:28:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:28:39 Integrated Voltage Measurement... 22:28:48 Voltage Offset Correction: v_off_ini = 602.079 uV, v_off_fin = 605.510 uV 22:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.437 uVs 22:28:48 Integrated Voltage Measurement... 22:28:57 Voltage Offset Correction: v_off_ini = 597.772 uV, v_off_fin = 604.078 uV 22:28:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.383 uVs 22:28:57 Integrated Voltage Measurement... 22:29:06 Voltage Offset Correction: v_off_ini = 602.976 uV, v_off_fin = 596.022 uV 22:29:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.737 uVs 22:29:06 Integrated Voltage Measurement... 22:29:15 Voltage Offset Correction: v_off_ini = 603.292 uV, v_off_fin = 603.347 uV 22:29:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.231 uVs 22:29:15 Integrated Voltage Measurement... 22:29:24 Voltage Offset Correction: v_off_ini = 604.232 uV, v_off_fin = 597.780 uV 22:29:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.649 uVs 22:29:24 Integrated Voltage Measurement... 22:29:33 Voltage Offset Correction: v_off_ini = 596.560 uV, v_off_fin = 603.350 uV 22:29:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.619 uVs 22:29:37 I1X Average and RMS of Measurements VT = -85.343 +- 3.039 uVs I1X = 17.069 +- 0.608 uTm 22:29:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:29:44 Integrated Voltage Measurement... 22:29:53 Voltage Offset Correction: v_off_ini = 605.221 uV, v_off_fin = 594.272 uV 22:29:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.736 uVs 22:29:53 Integrated Voltage Measurement... 22:30:02 Voltage Offset Correction: v_off_ini = 584.760 uV, v_off_fin = 600.511 uV 22:30:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.130 uVs 22:30:02 Integrated Voltage Measurement... 22:30:11 Voltage Offset Correction: v_off_ini = 585.232 uV, v_off_fin = 579.199 uV 22:30:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.224 uVs 22:30:11 Integrated Voltage Measurement... 22:30:20 Voltage Offset Correction: v_off_ini = 588.520 uV, v_off_fin = 591.552 uV 22:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.752 uVs 22:30:20 Integrated Voltage Measurement... 22:30:29 Voltage Offset Correction: v_off_ini = 581.636 uV, v_off_fin = 575.881 uV 22:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.076 uVs 22:30:29 Integrated Voltage Measurement... 22:30:38 Voltage Offset Correction: v_off_ini = 584.418 uV, v_off_fin = 593.864 uV 22:30:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.797 uVs 22:30:42 I1Y Average and RMS of Measurements VT = -193.452 +- 1.453 uVs I1Y = -38.688 +- 0.289 uTm 22:30:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:30:47 Integrated Voltage Measurement... 22:30:56 Voltage Offset Correction: v_off_ini = 581.664 uV, v_off_fin = 586.775 uV 22:30:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.870 uVs 22:30:56 Integrated Voltage Measurement... 22:31:05 Voltage Offset Correction: v_off_ini = 600.867 uV, v_off_fin = 593.495 uV 22:31:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.863 uVs 22:31:05 Integrated Voltage Measurement... 22:31:14 Voltage Offset Correction: v_off_ini = 595.004 uV, v_off_fin = 591.554 uV 22:31:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.026 uVs 22:31:14 Integrated Voltage Measurement... 22:31:23 Voltage Offset Correction: v_off_ini = 598.256 uV, v_off_fin = 599.081 uV 22:31:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.752 uVs 22:31:23 Integrated Voltage Measurement... 22:31:32 Voltage Offset Correction: v_off_ini = 606.046 uV, v_off_fin = 587.715 uV 22:31:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.732 uVs 22:31:32 Integrated Voltage Measurement... 22:31:41 Voltage Offset Correction: v_off_ini = 613.328 uV, v_off_fin = 616.814 uV 22:31:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.187 uVs 22:31:44 I2X Average and RMS of Measurements VT = -83.072 +- 0.853 uVs I2X = 7.643 +- 0.078 uTm^2 22:31:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 22:31:49 Integrated Voltage Measurement... 22:31:58 Voltage Offset Correction: v_off_ini = 592.873 uV, v_off_fin = 592.911 uV 22:31:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.085 uVs 22:31:58 Integrated Voltage Measurement... 22:32:07 Voltage Offset Correction: v_off_ini = 614.301 uV, v_off_fin = 602.242 uV 22:32:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.887 uVs 22:32:07 Integrated Voltage Measurement... 22:32:16 Voltage Offset Correction: v_off_ini = 602.222 uV, v_off_fin = 610.337 uV 22:32:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.950 uVs 22:32:16 Integrated Voltage Measurement... 22:32:25 Voltage Offset Correction: v_off_ini = 615.821 uV, v_off_fin = 611.072 uV 22:32:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.255 uVs 22:32:25 Integrated Voltage Measurement... 22:32:34 Voltage Offset Correction: v_off_ini = 603.514 uV, v_off_fin = 605.684 uV 22:32:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.014 uVs 22:32:34 Integrated Voltage Measurement... 22:32:43 Voltage Offset Correction: v_off_ini = 617.117 uV, v_off_fin = 617.241 uV 22:32:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.890 uVs 22:32:45 I2Y Average and RMS of Measurements VT = -305.347 +- 5.909 uVs I2Y = -28.092 +- 0.544 uTm^2 22:32:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:32:54 Integrated Voltage Measurement... 22:33:03 Voltage Offset Correction: v_off_ini = 598.694 uV, v_off_fin = 599.166 uV 22:33:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.799 uVs 22:33:03 Integrated Voltage Measurement... 22:33:12 Voltage Offset Correction: v_off_ini = 608.326 uV, v_off_fin = 611.553 uV 22:33:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.682 uVs 22:33:12 Integrated Voltage Measurement... 22:33:21 Voltage Offset Correction: v_off_ini = 615.475 uV, v_off_fin = 604.803 uV 22:33:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.382 uVs 22:33:21 Integrated Voltage Measurement... 22:33:30 Voltage Offset Correction: v_off_ini = 623.935 uV, v_off_fin = 620.180 uV 22:33:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.943 uVs 22:33:30 Integrated Voltage Measurement... 22:33:39 Voltage Offset Correction: v_off_ini = 617.243 uV, v_off_fin = 616.930 uV 22:33:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.062 uVs 22:33:39 Integrated Voltage Measurement... 22:33:48 Voltage Offset Correction: v_off_ini = 613.766 uV, v_off_fin = 627.070 uV 22:33:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.067 uVs 22:33:52 I1X Average and RMS of Measurements VT = -81.822 +- 4.111 uVs I1X = 16.365 +- 0.822 uTm 22:33:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:33:59 Integrated Voltage Measurement... 22:34:08 Voltage Offset Correction: v_off_ini = 615.793 uV, v_off_fin = 605.916 uV 22:34:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.112 uVs 22:34:08 Integrated Voltage Measurement... 22:34:17 Voltage Offset Correction: v_off_ini = 611.050 uV, v_off_fin = 627.844 uV 22:34:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.958 uVs 22:34:17 Integrated Voltage Measurement... 22:34:26 Voltage Offset Correction: v_off_ini = 621.107 uV, v_off_fin = 611.333 uV 22:34:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.054 uVs 22:34:26 Integrated Voltage Measurement... 22:34:35 Voltage Offset Correction: v_off_ini = 620.554 uV, v_off_fin = 610.615 uV 22:34:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.775 uVs 22:34:35 Integrated Voltage Measurement... 22:34:44 Voltage Offset Correction: v_off_ini = 622.525 uV, v_off_fin = 605.461 uV 22:34:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.011 uVs 22:34:44 Integrated Voltage Measurement... 22:34:53 Voltage Offset Correction: v_off_ini = 599.549 uV, v_off_fin = 619.129 uV 22:34:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.777 uVs 22:34:57 I1Y Average and RMS of Measurements VT = -195.448 +- 1.584 uVs I1Y = -39.088 +- 0.318 uTm 22:35:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:35:02 Integrated Voltage Measurement... 22:35:11 Voltage Offset Correction: v_off_ini = 603.791 uV, v_off_fin = 612.067 uV 22:35:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.501 uVs 22:35:11 Integrated Voltage Measurement... 22:35:20 Voltage Offset Correction: v_off_ini = 611.670 uV, v_off_fin = 620.301 uV 22:35:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.938 uVs 22:35:20 Integrated Voltage Measurement... 22:35:29 Voltage Offset Correction: v_off_ini = 604.198 uV, v_off_fin = 601.621 uV 22:35:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.571 uVs 22:35:29 Integrated Voltage Measurement... 22:35:38 Voltage Offset Correction: v_off_ini = 628.612 uV, v_off_fin = 624.036 uV 22:35:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.772 uVs 22:35:38 Integrated Voltage Measurement... 22:35:47 Voltage Offset Correction: v_off_ini = 616.147 uV, v_off_fin = 614.947 uV 22:35:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.781 uVs 22:35:47 Integrated Voltage Measurement... 22:35:56 Voltage Offset Correction: v_off_ini = 597.728 uV, v_off_fin = 605.162 uV 22:35:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.580 uVs 22:35:59 I2X Average and RMS of Measurements VT = -78.690 +- 7.465 uVs I2X = 7.240 +- 0.687 uTm^2 22:36:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 22:36:04 Integrated Voltage Measurement... 22:36:13 Voltage Offset Correction: v_off_ini = 607.943 uV, v_off_fin = 605.146 uV 22:36:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.881 uVs 22:36:13 Integrated Voltage Measurement... 22:36:22 Voltage Offset Correction: v_off_ini = 615.871 uV, v_off_fin = 623.902 uV 22:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.321 uVs 22:36:22 Integrated Voltage Measurement... 22:36:31 Voltage Offset Correction: v_off_ini = 621.123 uV, v_off_fin = 606.225 uV 22:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.129 uVs 22:36:31 Integrated Voltage Measurement... 22:36:40 Voltage Offset Correction: v_off_ini = 604.200 uV, v_off_fin = 607.744 uV 22:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.237 uVs 22:36:40 Integrated Voltage Measurement... 22:36:49 Voltage Offset Correction: v_off_ini = 608.473 uV, v_off_fin = 605.250 uV 22:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.153 uVs 22:36:49 Integrated Voltage Measurement... 22:36:58 Voltage Offset Correction: v_off_ini = 619.678 uV, v_off_fin = 618.683 uV 22:36:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.547 uVs 22:37:01 I2Y Average and RMS of Measurements VT = -310.044 +- 6.879 uVs I2Y = -28.524 +- 0.633 uTm^2 22:37:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm