SLAC Magnetic Measurements Date: 07-17-2025 Time: 14:58:11 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16353 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 6 Measurement Device: Operator: YL Comment: 14:58:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:21 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:58:23 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:58:24 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:58:26 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:58:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:41 Integrated Voltage Measurement... 14:58:50 Voltage Offset Correction: v_off_ini = 13.448 uV, v_off_fin = 3.554 uV 14:58:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.241 uVs 14:58:50 Integrated Voltage Measurement... 14:58:59 Voltage Offset Correction: v_off_ini = 9.903 uV, v_off_fin = 13.946 uV 14:58:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.256 uVs 14:58:59 Integrated Voltage Measurement... 14:59:08 Voltage Offset Correction: v_off_ini = 22.990 uV, v_off_fin = 21.854 uV 14:59:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.036 uVs 14:59:08 Integrated Voltage Measurement... 14:59:17 Voltage Offset Correction: v_off_ini = 17.356 uV, v_off_fin = 36.124 uV 14:59:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.072 uVs 14:59:17 Integrated Voltage Measurement... 14:59:26 Voltage Offset Correction: v_off_ini = 45.840 uV, v_off_fin = 46.885 uV 14:59:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.210 uVs 14:59:26 Integrated Voltage Measurement... 14:59:35 Voltage Offset Correction: v_off_ini = 51.175 uV, v_off_fin = 50.178 uV 14:59:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.245 uVs 14:59:39 I1X Average and RMS of Measurements VT = -28.343 +- 1.618 uVs I1X = 5.669 +- 0.324 uTm 14:59:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:46 Integrated Voltage Measurement... 14:59:55 Voltage Offset Correction: v_off_ini = 53.365 uV, v_off_fin = 51.802 uV 14:59:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -177.647 uVs 14:59:55 Integrated Voltage Measurement... 15:00:04 Voltage Offset Correction: v_off_ini = 48.122 uV, v_off_fin = 69.318 uV 15:00:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.544 uVs 15:00:04 Integrated Voltage Measurement... 15:00:13 Voltage Offset Correction: v_off_ini = 55.176 uV, v_off_fin = 59.643 uV 15:00:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.273 uVs 15:00:13 Integrated Voltage Measurement... 15:00:22 Voltage Offset Correction: v_off_ini = 77.780 uV, v_off_fin = 90.693 uV 15:00:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.344 uVs 15:00:22 Integrated Voltage Measurement... 15:00:31 Voltage Offset Correction: v_off_ini = 77.970 uV, v_off_fin = 55.890 uV 15:00:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.443 uVs 15:00:31 Integrated Voltage Measurement... 15:00:40 Voltage Offset Correction: v_off_ini = 79.087 uV, v_off_fin = 72.598 uV 15:00:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.590 uVs 15:00:44 I1Y Average and RMS of Measurements VT = -190.473 +- 3.695 uVs I1Y = -38.093 +- 0.740 uTm 15:00:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:52 Integrated Voltage Measurement... 15:01:01 Voltage Offset Correction: v_off_ini = 87.629 uV, v_off_fin = 92.781 uV 15:01:01 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -8.369 uVs 15:01:01 Integrated Voltage Measurement... 15:01:10 Voltage Offset Correction: v_off_ini = 108.944 uV, v_off_fin = 112.892 uV 15:01:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -15.614 uVs 15:01:10 Integrated Voltage Measurement... 15:01:19 Voltage Offset Correction: v_off_ini = 122.553 uV, v_off_fin = 95.287 uV 15:01:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 1.759 uVs 15:01:19 Integrated Voltage Measurement... 15:01:28 Voltage Offset Correction: v_off_ini = 103.952 uV, v_off_fin = 128.097 uV 15:01:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -2.766 uVs 15:01:28 Integrated Voltage Measurement... 15:01:37 Voltage Offset Correction: v_off_ini = 112.071 uV, v_off_fin = 117.588 uV 15:01:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 29.851 uVs 15:01:37 Integrated Voltage Measurement... 15:01:46 Voltage Offset Correction: v_off_ini = 125.473 uV, v_off_fin = 138.487 uV 15:01:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -34.295 uVs 15:01:49 I2X Average and RMS of Measurements VT = 12.653 +- 13.743 uVs I2X = -1.164 +- 1.264 uTm^2 15:01:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:56 Integrated Voltage Measurement... 15:02:05 Voltage Offset Correction: v_off_ini = 129.928 uV, v_off_fin = 129.590 uV 15:02:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.787 uVs 15:02:05 Integrated Voltage Measurement... 15:02:14 Voltage Offset Correction: v_off_ini = 124.629 uV, v_off_fin = 128.440 uV 15:02:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 519.587 uVs 15:02:14 Integrated Voltage Measurement... 15:02:23 Voltage Offset Correction: v_off_ini = 130.015 uV, v_off_fin = 118.047 uV 15:02:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -534.174 uVs 15:02:23 Integrated Voltage Measurement... 15:02:32 Voltage Offset Correction: v_off_ini = 126.384 uV, v_off_fin = 126.942 uV 15:02:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 532.575 uVs 15:02:32 Integrated Voltage Measurement... 15:02:41 Voltage Offset Correction: v_off_ini = 126.642 uV, v_off_fin = 124.582 uV 15:02:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.011 uVs 15:02:42 Integrated Voltage Measurement... 15:02:51 Voltage Offset Correction: v_off_ini = 125.729 uV, v_off_fin = 122.569 uV 15:02:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 515.334 uVs 15:02:53 I2Y Average and RMS of Measurements VT = -523.578 +- 6.940 uVs I2Y = -48.170 +- 0.638 uTm^2 15:03:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:08 Integrated Voltage Measurement... 15:03:17 Voltage Offset Correction: v_off_ini = 135.479 uV, v_off_fin = 132.701 uV 15:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.010 uVs 15:03:17 Integrated Voltage Measurement... 15:03:26 Voltage Offset Correction: v_off_ini = 127.924 uV, v_off_fin = 130.696 uV 15:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.961 uVs 15:03:26 Integrated Voltage Measurement... 15:03:35 Voltage Offset Correction: v_off_ini = 133.680 uV, v_off_fin = 146.682 uV 15:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.216 uVs 15:03:35 Integrated Voltage Measurement... 15:03:44 Voltage Offset Correction: v_off_ini = 135.409 uV, v_off_fin = 149.715 uV 15:03:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 17.353 uVs 15:03:44 Integrated Voltage Measurement... 15:03:53 Voltage Offset Correction: v_off_ini = 150.390 uV, v_off_fin = 148.812 uV 15:03:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.937 uVs 15:03:53 Integrated Voltage Measurement... 15:04:02 Voltage Offset Correction: v_off_ini = 152.602 uV, v_off_fin = 158.437 uV 15:04:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.492 uVs 15:04:06 I1X Average and RMS of Measurements VT = -31.495 +- 3.150 uVs I1X = 6.299 +- 0.630 uTm 15:04:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:13 Integrated Voltage Measurement... 15:04:22 Voltage Offset Correction: v_off_ini = 152.378 uV, v_off_fin = 135.253 uV 15:04:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.629 uVs 15:04:22 Integrated Voltage Measurement... 15:04:31 Voltage Offset Correction: v_off_ini = 141.072 uV, v_off_fin = 154.264 uV 15:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.025 uVs 15:04:31 Integrated Voltage Measurement... 15:04:40 Voltage Offset Correction: v_off_ini = 147.863 uV, v_off_fin = 147.225 uV 15:04:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.242 uVs 15:04:40 Integrated Voltage Measurement... 15:04:49 Voltage Offset Correction: v_off_ini = 149.234 uV, v_off_fin = 167.571 uV 15:04:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.103 uVs 15:04:49 Integrated Voltage Measurement... 15:04:58 Voltage Offset Correction: v_off_ini = 171.783 uV, v_off_fin = 162.353 uV 15:04:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.107 uVs 15:04:58 Integrated Voltage Measurement... 15:05:07 Voltage Offset Correction: v_off_ini = 177.751 uV, v_off_fin = 180.958 uV 15:05:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.562 uVs 15:05:11 I1Y Average and RMS of Measurements VT = -191.111 +- 2.731 uVs I1Y = -38.218 +- 0.546 uTm 15:05:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:19 Integrated Voltage Measurement... 15:05:28 Voltage Offset Correction: v_off_ini = 181.414 uV, v_off_fin = 183.019 uV 15:05:28 Integrated Voltage Measurement dXYus = -1.0003 mm, dXYds = 0.0000 mm dXY = -1.0003 mm VT = -9.985 uVs 15:05:28 Integrated Voltage Measurement... 15:05:37 Voltage Offset Correction: v_off_ini = 197.750 uV, v_off_fin = 197.253 uV 15:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 4.041 uVs 15:05:37 Integrated Voltage Measurement... 15:05:46 Voltage Offset Correction: v_off_ini = 190.821 uV, v_off_fin = 181.714 uV 15:05:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.842 uVs 15:05:46 Integrated Voltage Measurement... 15:05:55 Voltage Offset Correction: v_off_ini = 192.492 uV, v_off_fin = 208.395 uV 15:05:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -11.450 uVs 15:05:55 Integrated Voltage Measurement... 15:06:04 Voltage Offset Correction: v_off_ini = 203.137 uV, v_off_fin = 193.533 uV 15:06:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -11.677 uVs 15:06:04 Integrated Voltage Measurement... 15:06:13 Voltage Offset Correction: v_off_ini = 210.493 uV, v_off_fin = 231.622 uV 15:06:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.616 uVs 15:06:15 I2X Average and RMS of Measurements VT = -4.452 +- 7.153 uVs I2X = 0.410 +- 0.658 uTm^2 15:06:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:23 Integrated Voltage Measurement... 15:06:32 Voltage Offset Correction: v_off_ini = 224.165 uV, v_off_fin = 213.032 uV 15:06:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -532.572 uVs 15:06:32 Integrated Voltage Measurement... 15:06:41 Voltage Offset Correction: v_off_ini = 223.528 uV, v_off_fin = 223.251 uV 15:06:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 522.835 uVs 15:06:41 Integrated Voltage Measurement... 15:06:50 Voltage Offset Correction: v_off_ini = 215.473 uV, v_off_fin = 223.098 uV 15:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.616 uVs 15:06:50 Integrated Voltage Measurement... 15:06:59 Voltage Offset Correction: v_off_ini = 236.423 uV, v_off_fin = 234.468 uV 15:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.716 uVs 15:06:59 Integrated Voltage Measurement... 15:07:08 Voltage Offset Correction: v_off_ini = 230.278 uV, v_off_fin = 229.880 uV 15:07:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.469 uVs 15:07:08 Integrated Voltage Measurement... 15:07:17 Voltage Offset Correction: v_off_ini = 238.168 uV, v_off_fin = 236.144 uV 15:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 524.672 uVs 15:07:19 I2Y Average and RMS of Measurements VT = -521.147 +- 6.288 uVs I2Y = -47.945 +- 0.579 uTm^2