SLAC Magnetic Measurements Date: 07-18-2025 Time: 13:02:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16353 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 14 Measurement Device: Operator: YL Comment: Off Axis 13:03:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:05 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:03:07 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:03:08 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:03:10 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:03:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:03:52 Integrated Voltage Measurement... 13:04:01 Voltage Offset Correction: v_off_ini = 642.048 uV, v_off_fin = 597.399 uV 13:04:01 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -80.770 uVs 13:04:01 Integrated Voltage Measurement... 13:04:10 Voltage Offset Correction: v_off_ini = 606.070 uV, v_off_fin = 606.487 uV 13:04:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.875 uVs 13:04:10 Integrated Voltage Measurement... 13:04:19 Voltage Offset Correction: v_off_ini = 619.703 uV, v_off_fin = 618.505 uV 13:04:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.805 uVs 13:04:19 Integrated Voltage Measurement... 13:04:28 Voltage Offset Correction: v_off_ini = 626.391 uV, v_off_fin = 614.035 uV 13:04:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.677 uVs 13:04:28 Integrated Voltage Measurement... 13:04:37 Voltage Offset Correction: v_off_ini = 607.113 uV, v_off_fin = 606.525 uV 13:04:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.113 uVs 13:04:37 Integrated Voltage Measurement... 13:04:46 Voltage Offset Correction: v_off_ini = 615.157 uV, v_off_fin = 619.268 uV 13:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 65.317 uVs 13:04:50 I1X Average and RMS of Measurements VT = -65.259 +- 1.825 uVs I1X = 13.053 +- 0.366 uTm 13:04:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:04:57 Integrated Voltage Measurement... 13:05:06 Voltage Offset Correction: v_off_ini = 632.907 uV, v_off_fin = 616.152 uV 13:05:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.260 uVs 13:05:06 Integrated Voltage Measurement... 13:05:15 Voltage Offset Correction: v_off_ini = 626.458 uV, v_off_fin = 642.311 uV 13:05:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.185 uVs 13:05:15 Integrated Voltage Measurement... 13:05:24 Voltage Offset Correction: v_off_ini = 626.658 uV, v_off_fin = 617.961 uV 13:05:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.050 uVs 13:05:24 Integrated Voltage Measurement... 13:05:33 Voltage Offset Correction: v_off_ini = 632.871 uV, v_off_fin = 640.797 uV 13:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.032 uVs 13:05:33 Integrated Voltage Measurement... 13:05:42 Voltage Offset Correction: v_off_ini = 639.976 uV, v_off_fin = 632.545 uV 13:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.819 uVs 13:05:42 Integrated Voltage Measurement... 13:05:51 Voltage Offset Correction: v_off_ini = 629.710 uV, v_off_fin = 639.801 uV 13:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.678 uVs 13:05:55 I1Y Average and RMS of Measurements VT = -200.004 +- 5.807 uVs I1Y = -40.001 +- 1.161 uTm 13:06:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:06:03 Integrated Voltage Measurement... 13:06:12 Voltage Offset Correction: v_off_ini = 620.934 uV, v_off_fin = 623.779 uV 13:06:12 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -46.737 uVs 13:06:12 Integrated Voltage Measurement... 13:06:21 Voltage Offset Correction: v_off_ini = 646.616 uV, v_off_fin = 649.478 uV 13:06:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.304 uVs 13:06:21 Integrated Voltage Measurement... 13:06:30 Voltage Offset Correction: v_off_ini = 631.914 uV, v_off_fin = 624.870 uV 13:06:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -39.134 uVs 13:06:30 Integrated Voltage Measurement... 13:06:39 Voltage Offset Correction: v_off_ini = 630.603 uV, v_off_fin = 645.767 uV 13:06:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.130 uVs 13:06:39 Integrated Voltage Measurement... 13:06:48 Voltage Offset Correction: v_off_ini = 640.636 uV, v_off_fin = 632.820 uV 13:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.392 uVs 13:06:48 Integrated Voltage Measurement... 13:06:57 Voltage Offset Correction: v_off_ini = 634.966 uV, v_off_fin = 650.644 uV 13:06:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.221 uVs 13:07:00 I2X Average and RMS of Measurements VT = -31.486 +- 4.828 uVs I2X = 2.897 +- 0.444 uTm^2 13:07:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:07:07 Integrated Voltage Measurement... 13:07:16 Voltage Offset Correction: v_off_ini = 638.494 uV, v_off_fin = 636.004 uV 13:07:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -527.475 uVs 13:07:16 Integrated Voltage Measurement... 13:07:25 Voltage Offset Correction: v_off_ini = 643.141 uV, v_off_fin = 641.305 uV 13:07:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 540.052 uVs 13:07:25 Integrated Voltage Measurement... 13:07:34 Voltage Offset Correction: v_off_ini = 635.033 uV, v_off_fin = 623.432 uV 13:07:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -522.983 uVs 13:07:34 Integrated Voltage Measurement... 13:07:43 Voltage Offset Correction: v_off_ini = 641.252 uV, v_off_fin = 632.600 uV 13:07:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.363 uVs 13:07:44 Integrated Voltage Measurement... 13:07:53 Voltage Offset Correction: v_off_ini = 618.026 uV, v_off_fin = 636.667 uV 13:07:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -531.589 uVs 13:07:53 Integrated Voltage Measurement... 13:08:02 Voltage Offset Correction: v_off_ini = 632.017 uV, v_off_fin = 625.436 uV 13:08:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.672 uVs 13:08:04 I2Y Average and RMS of Measurements VT = -523.856 +- 7.009 uVs I2Y = -48.195 +- 0.645 uTm^2 13:08:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:08:13 Integrated Voltage Measurement... 13:08:22 Voltage Offset Correction: v_off_ini = 628.510 uV, v_off_fin = 618.475 uV 13:08:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -56.336 uVs 13:08:22 Integrated Voltage Measurement... 13:08:31 Voltage Offset Correction: v_off_ini = 634.514 uV, v_off_fin = 639.196 uV 13:08:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.266 uVs 13:08:31 Integrated Voltage Measurement... 13:08:40 Voltage Offset Correction: v_off_ini = 649.397 uV, v_off_fin = 638.141 uV 13:08:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.652 uVs 13:08:40 Integrated Voltage Measurement... 13:08:49 Voltage Offset Correction: v_off_ini = 646.715 uV, v_off_fin = 644.711 uV 13:08:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.383 uVs 13:08:49 Integrated Voltage Measurement... 13:08:58 Voltage Offset Correction: v_off_ini = 653.431 uV, v_off_fin = 655.171 uV 13:08:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.457 uVs 13:08:58 Integrated Voltage Measurement... 13:09:07 Voltage Offset Correction: v_off_ini = 650.039 uV, v_off_fin = 641.937 uV 13:09:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.501 uVs 13:09:11 I1X Average and RMS of Measurements VT = -68.599 +- 5.192 uVs I1X = 13.720 +- 1.038 uTm 13:09:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:09:18 Integrated Voltage Measurement... 13:09:27 Voltage Offset Correction: v_off_ini = 637.066 uV, v_off_fin = 641.710 uV 13:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.674 uVs 13:09:27 Integrated Voltage Measurement... 13:09:36 Voltage Offset Correction: v_off_ini = 632.260 uV, v_off_fin = 651.177 uV 13:09:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.857 uVs 13:09:36 Integrated Voltage Measurement... 13:09:45 Voltage Offset Correction: v_off_ini = 645.404 uV, v_off_fin = 627.330 uV 13:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.580 uVs 13:09:45 Integrated Voltage Measurement... 13:09:54 Voltage Offset Correction: v_off_ini = 637.965 uV, v_off_fin = 643.273 uV 13:09:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.922 uVs 13:09:54 Integrated Voltage Measurement... 13:10:03 Voltage Offset Correction: v_off_ini = 634.367 uV, v_off_fin = 631.165 uV 13:10:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.186 uVs 13:10:03 Integrated Voltage Measurement... 13:10:12 Voltage Offset Correction: v_off_ini = 641.481 uV, v_off_fin = 655.432 uV 13:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.611 uVs 13:10:16 I1Y Average and RMS of Measurements VT = -205.138 +- 4.804 uVs I1Y = -41.028 +- 0.961 uTm 13:10:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:10:24 Integrated Voltage Measurement... 13:10:33 Voltage Offset Correction: v_off_ini = 640.293 uV, v_off_fin = 639.299 uV 13:10:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -32.893 uVs 13:10:33 Integrated Voltage Measurement... 13:10:42 Voltage Offset Correction: v_off_ini = 648.732 uV, v_off_fin = 650.022 uV 13:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.008 uVs 13:10:42 Integrated Voltage Measurement... 13:10:51 Voltage Offset Correction: v_off_ini = 647.472 uV, v_off_fin = 633.618 uV 13:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.548 uVs 13:10:51 Integrated Voltage Measurement... 13:11:00 Voltage Offset Correction: v_off_ini = 657.653 uV, v_off_fin = 659.832 uV 13:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.006 uVs 13:11:00 Integrated Voltage Measurement... 13:11:09 Voltage Offset Correction: v_off_ini = 640.849 uV, v_off_fin = 640.547 uV 13:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -20.826 uVs 13:11:09 Integrated Voltage Measurement... 13:11:18 Voltage Offset Correction: v_off_ini = 653.590 uV, v_off_fin = 667.282 uV 13:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.511 uVs 13:11:21 I2X Average and RMS of Measurements VT = -29.132 +- 0.335 uVs I2X = 2.680 +- 0.031 uTm^2 13:11:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:11:29 Integrated Voltage Measurement... 13:11:38 Voltage Offset Correction: v_off_ini = 660.161 uV, v_off_fin = 668.001 uV 13:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -535.131 uVs 13:11:38 Integrated Voltage Measurement... 13:11:47 Voltage Offset Correction: v_off_ini = 657.084 uV, v_off_fin = 654.432 uV 13:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 526.819 uVs 13:11:47 Integrated Voltage Measurement... 13:11:56 Voltage Offset Correction: v_off_ini = 652.926 uV, v_off_fin = 659.015 uV 13:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.329 uVs 13:11:56 Integrated Voltage Measurement... 13:12:05 Voltage Offset Correction: v_off_ini = 667.484 uV, v_off_fin = 663.772 uV 13:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 542.083 uVs 13:12:05 Integrated Voltage Measurement... 13:12:14 Voltage Offset Correction: v_off_ini = 663.861 uV, v_off_fin = 647.608 uV 13:12:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -533.535 uVs 13:12:14 Integrated Voltage Measurement... 13:12:23 Voltage Offset Correction: v_off_ini = 650.303 uV, v_off_fin = 653.911 uV 13:12:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 532.862 uVs 13:12:25 I2Y Average and RMS of Measurements VT = -530.626 +- 2.256 uVs I2Y = -48.818 +- 0.208 uTm^2 13:12:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:34 Integrated Voltage Measurement... 13:12:43 Voltage Offset Correction: v_off_ini = 662.072 uV, v_off_fin = 650.318 uV 13:12:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -65.822 uVs 13:12:43 Integrated Voltage Measurement... 13:12:52 Voltage Offset Correction: v_off_ini = 645.330 uV, v_off_fin = 653.346 uV 13:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.602 uVs 13:12:52 Integrated Voltage Measurement... 13:13:01 Voltage Offset Correction: v_off_ini = 640.964 uV, v_off_fin = 651.680 uV 13:13:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.960 uVs 13:13:01 Integrated Voltage Measurement... 13:13:10 Voltage Offset Correction: v_off_ini = 661.930 uV, v_off_fin = 665.693 uV 13:13:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.666 uVs 13:13:10 Integrated Voltage Measurement... 13:13:19 Voltage Offset Correction: v_off_ini = 650.010 uV, v_off_fin = 657.059 uV 13:13:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.647 uVs 13:13:19 Integrated Voltage Measurement... 13:13:28 Voltage Offset Correction: v_off_ini = 642.503 uV, v_off_fin = 651.361 uV 13:13:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.703 uVs 13:13:33 I1X Average and RMS of Measurements VT = -65.067 +- 8.364 uVs I1X = 13.014 +- 1.674 uTm 13:13:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:39 Integrated Voltage Measurement... 13:13:48 Voltage Offset Correction: v_off_ini = 641.344 uV, v_off_fin = 638.513 uV 13:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.055 uVs 13:13:48 Integrated Voltage Measurement... 13:13:57 Voltage Offset Correction: v_off_ini = 661.075 uV, v_off_fin = 657.284 uV 13:13:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.019 uVs 13:13:57 Integrated Voltage Measurement... 13:14:06 Voltage Offset Correction: v_off_ini = 656.129 uV, v_off_fin = 644.333 uV 13:14:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.603 uVs 13:14:06 Integrated Voltage Measurement... 13:14:15 Voltage Offset Correction: v_off_ini = 647.806 uV, v_off_fin = 650.401 uV 13:14:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.417 uVs 13:14:15 Integrated Voltage Measurement... 13:14:24 Voltage Offset Correction: v_off_ini = 635.358 uV, v_off_fin = 618.907 uV 13:14:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.718 uVs 13:14:24 Integrated Voltage Measurement... 13:14:33 Voltage Offset Correction: v_off_ini = 603.337 uV, v_off_fin = 625.757 uV 13:14:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.707 uVs 13:14:38 I1Y Average and RMS of Measurements VT = -192.420 +- 6.067 uVs I1Y = -38.484 +- 1.213 uTm 13:14:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:45 Integrated Voltage Measurement... 13:14:54 Voltage Offset Correction: v_off_ini = 622.265 uV, v_off_fin = 619.834 uV 13:14:54 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -35.125 uVs 13:14:54 Integrated Voltage Measurement... 13:15:03 Voltage Offset Correction: v_off_ini = 621.348 uV, v_off_fin = 650.689 uV 13:15:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 12.643 uVs 13:15:04 Integrated Voltage Measurement... 13:15:13 Voltage Offset Correction: v_off_ini = 641.720 uV, v_off_fin = 630.277 uV 13:15:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.680 uVs 13:15:13 Integrated Voltage Measurement... 13:15:22 Voltage Offset Correction: v_off_ini = 639.522 uV, v_off_fin = 653.445 uV 13:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 9.994 uVs 13:15:22 Integrated Voltage Measurement... 13:15:31 Voltage Offset Correction: v_off_ini = 630.934 uV, v_off_fin = 627.197 uV 13:15:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.920 uVs 13:15:31 Integrated Voltage Measurement... 13:15:40 Voltage Offset Correction: v_off_ini = 639.952 uV, v_off_fin = 634.244 uV 13:15:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.482 uVs 13:15:42 I2X Average and RMS of Measurements VT = -27.474 +- 6.203 uVs I2X = 2.528 +- 0.571 uTm^2 13:15:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:50 Integrated Voltage Measurement... 13:15:59 Voltage Offset Correction: v_off_ini = 633.927 uV, v_off_fin = 634.716 uV 13:15:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.064 uVs 13:15:59 Integrated Voltage Measurement... 13:16:08 Voltage Offset Correction: v_off_ini = 631.924 uV, v_off_fin = 639.302 uV 13:16:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 527.977 uVs 13:16:08 Integrated Voltage Measurement... 13:16:17 Voltage Offset Correction: v_off_ini = 636.081 uV, v_off_fin = 636.769 uV 13:16:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -526.097 uVs 13:16:17 Integrated Voltage Measurement... 13:16:26 Voltage Offset Correction: v_off_ini = 634.050 uV, v_off_fin = 640.399 uV 13:16:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.746 uVs 13:16:26 Integrated Voltage Measurement... 13:16:35 Voltage Offset Correction: v_off_ini = 631.882 uV, v_off_fin = 635.315 uV 13:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -525.329 uVs 13:16:35 Integrated Voltage Measurement... 13:16:44 Voltage Offset Correction: v_off_ini = 626.643 uV, v_off_fin = 629.393 uV 13:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 521.626 uVs 13:16:47 I2Y Average and RMS of Measurements VT = -523.307 +- 0.204 uVs I2Y = -48.145 +- 0.018 uTm^2 13:16:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:16:55 Integrated Voltage Measurement... 13:17:04 Voltage Offset Correction: v_off_ini = 620.732 uV, v_off_fin = 611.018 uV 13:17:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.468 uVs 13:17:04 Integrated Voltage Measurement... 13:17:13 Voltage Offset Correction: v_off_ini = 609.179 uV, v_off_fin = 612.159 uV 13:17:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.830 uVs 13:17:14 Integrated Voltage Measurement... 13:17:22 Voltage Offset Correction: v_off_ini = 617.127 uV, v_off_fin = 623.025 uV 13:17:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.620 uVs 13:17:23 Integrated Voltage Measurement... 13:17:31 Voltage Offset Correction: v_off_ini = 626.975 uV, v_off_fin = 633.894 uV 13:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.490 uVs 13:17:32 Integrated Voltage Measurement... 13:17:41 Voltage Offset Correction: v_off_ini = 619.295 uV, v_off_fin = 611.519 uV 13:17:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.821 uVs 13:17:41 Integrated Voltage Measurement... 13:17:50 Voltage Offset Correction: v_off_ini = 619.307 uV, v_off_fin = 617.233 uV 13:17:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.089 uVs 13:17:54 I1X Average and RMS of Measurements VT = -65.886 +- 9.292 uVs I1X = 13.178 +- 1.858 uTm 13:17:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:18:01 Integrated Voltage Measurement... 13:18:10 Voltage Offset Correction: v_off_ini = 623.690 uV, v_off_fin = 617.882 uV 13:18:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -194.489 uVs 13:18:10 Integrated Voltage Measurement... 13:18:19 Voltage Offset Correction: v_off_ini = 620.529 uV, v_off_fin = 631.241 uV 13:18:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.619 uVs 13:18:19 Integrated Voltage Measurement... 13:18:28 Voltage Offset Correction: v_off_ini = 612.227 uV, v_off_fin = 617.457 uV 13:18:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.195 uVs 13:18:28 Integrated Voltage Measurement... 13:18:37 Voltage Offset Correction: v_off_ini = 622.931 uV, v_off_fin = 627.121 uV 13:18:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.212 uVs 13:18:37 Integrated Voltage Measurement... 13:18:46 Voltage Offset Correction: v_off_ini = 622.191 uV, v_off_fin = 620.605 uV 13:18:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.110 uVs 13:18:46 Integrated Voltage Measurement... 13:18:55 Voltage Offset Correction: v_off_ini = 617.588 uV, v_off_fin = 635.661 uV 13:18:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.230 uVs 13:18:59 I1Y Average and RMS of Measurements VT = -196.142 +- 2.872 uVs I1Y = -39.229 +- 0.574 uTm 13:19:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:19:07 Integrated Voltage Measurement... 13:19:16 Voltage Offset Correction: v_off_ini = 605.879 uV, v_off_fin = 596.001 uV 13:19:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -51.984 uVs 13:19:16 Integrated Voltage Measurement... 13:19:25 Voltage Offset Correction: v_off_ini = 602.651 uV, v_off_fin = 620.251 uV 13:19:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 36.164 uVs 13:19:25 Integrated Voltage Measurement... 13:19:34 Voltage Offset Correction: v_off_ini = 610.107 uV, v_off_fin = 603.916 uV 13:19:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.922 uVs 13:19:34 Integrated Voltage Measurement... 13:19:43 Voltage Offset Correction: v_off_ini = 620.590 uV, v_off_fin = 618.428 uV 13:19:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.210 uVs 13:19:43 Integrated Voltage Measurement... 13:19:52 Voltage Offset Correction: v_off_ini = 619.482 uV, v_off_fin = 610.089 uV 13:19:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.015 uVs 13:19:52 Integrated Voltage Measurement... 13:20:01 Voltage Offset Correction: v_off_ini = 627.626 uV, v_off_fin = 627.054 uV 13:20:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.757 uVs 13:20:03 I2X Average and RMS of Measurements VT = -40.175 +- 7.727 uVs I2X = 3.696 +- 0.711 uTm^2 13:20:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:20:11 Integrated Voltage Measurement... 13:20:20 Voltage Offset Correction: v_off_ini = 618.320 uV, v_off_fin = 611.777 uV 13:20:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.486 uVs 13:20:20 Integrated Voltage Measurement... 13:20:29 Voltage Offset Correction: v_off_ini = 615.847 uV, v_off_fin = 610.409 uV 13:20:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 539.510 uVs 13:20:29 Integrated Voltage Measurement... 13:20:38 Voltage Offset Correction: v_off_ini = 623.938 uV, v_off_fin = 623.133 uV 13:20:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -519.237 uVs 13:20:38 Integrated Voltage Measurement... 13:20:47 Voltage Offset Correction: v_off_ini = 622.488 uV, v_off_fin = 626.434 uV 13:20:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 533.639 uVs 13:20:47 Integrated Voltage Measurement... 13:20:56 Voltage Offset Correction: v_off_ini = 622.015 uV, v_off_fin = 621.775 uV 13:20:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -524.283 uVs 13:20:56 Integrated Voltage Measurement... 13:21:05 Voltage Offset Correction: v_off_ini = 633.431 uV, v_off_fin = 623.357 uV 13:21:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.182 uVs 13:21:08 I2Y Average and RMS of Measurements VT = -523.056 +- 3.215 uVs I2Y = -48.121 +- 0.296 uTm^2 13:21:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:21:17 Integrated Voltage Measurement... 13:21:26 Voltage Offset Correction: v_off_ini = 624.141 uV, v_off_fin = 614.468 uV 13:21:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.260 uVs 13:21:26 Integrated Voltage Measurement... 13:21:35 Voltage Offset Correction: v_off_ini = 628.829 uV, v_off_fin = 630.102 uV 13:21:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.259 uVs 13:21:35 Integrated Voltage Measurement... 13:21:44 Voltage Offset Correction: v_off_ini = 641.695 uV, v_off_fin = 633.313 uV 13:21:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.000 uVs 13:21:44 Integrated Voltage Measurement... 13:21:53 Voltage Offset Correction: v_off_ini = 632.610 uV, v_off_fin = 632.749 uV 13:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.087 uVs 13:21:53 Integrated Voltage Measurement... 13:22:02 Voltage Offset Correction: v_off_ini = 617.123 uV, v_off_fin = 626.187 uV 13:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.432 uVs 13:22:02 Integrated Voltage Measurement... 13:22:11 Voltage Offset Correction: v_off_ini = 611.141 uV, v_off_fin = 635.373 uV 13:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.501 uVs 13:22:15 I1X Average and RMS of Measurements VT = -72.756 +- 1.936 uVs I1X = 14.552 +- 0.387 uTm 13:22:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:22:22 Integrated Voltage Measurement... 13:22:31 Voltage Offset Correction: v_off_ini = 658.011 uV, v_off_fin = 640.962 uV 13:22:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.981 uVs 13:22:31 Integrated Voltage Measurement... 13:22:40 Voltage Offset Correction: v_off_ini = 663.340 uV, v_off_fin = 667.560 uV 13:22:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.895 uVs 13:22:40 Integrated Voltage Measurement... 13:22:49 Voltage Offset Correction: v_off_ini = 657.557 uV, v_off_fin = 647.885 uV 13:22:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.391 uVs 13:22:49 Integrated Voltage Measurement... 13:22:58 Voltage Offset Correction: v_off_ini = 658.668 uV, v_off_fin = 663.578 uV 13:22:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.317 uVs 13:22:58 Integrated Voltage Measurement... 13:23:07 Voltage Offset Correction: v_off_ini = 649.063 uV, v_off_fin = 641.036 uV 13:23:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.708 uVs 13:23:07 Integrated Voltage Measurement... 13:23:16 Voltage Offset Correction: v_off_ini = 651.605 uV, v_off_fin = 658.232 uV 13:23:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.242 uVs 13:23:20 I1Y Average and RMS of Measurements VT = -181.589 +- 3.809 uVs I1Y = -36.318 +- 0.762 uTm 13:23:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:23:28 Integrated Voltage Measurement... 13:23:37 Voltage Offset Correction: v_off_ini = 651.166 uV, v_off_fin = 655.648 uV 13:23:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -19.090 uVs 13:23:37 Integrated Voltage Measurement... 13:23:46 Voltage Offset Correction: v_off_ini = 656.159 uV, v_off_fin = 635.328 uV 13:23:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.612 uVs 13:23:46 Integrated Voltage Measurement... 13:23:55 Voltage Offset Correction: v_off_ini = 641.839 uV, v_off_fin = 610.180 uV 13:23:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.241 uVs 13:23:55 Integrated Voltage Measurement... 13:24:04 Voltage Offset Correction: v_off_ini = 638.585 uV, v_off_fin = 642.268 uV 13:24:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.789 uVs 13:24:04 Integrated Voltage Measurement... 13:24:13 Voltage Offset Correction: v_off_ini = 631.881 uV, v_off_fin = 632.864 uV 13:24:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.091 uVs 13:24:13 Integrated Voltage Measurement... 13:24:22 Voltage Offset Correction: v_off_ini = 653.562 uV, v_off_fin = 644.954 uV 13:24:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.672 uVs 13:24:24 I2X Average and RMS of Measurements VT = -34.249 +- 6.828 uVs I2X = 3.151 +- 0.628 uTm^2 13:24:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:24:32 Integrated Voltage Measurement... 13:24:41 Voltage Offset Correction: v_off_ini = 644.562 uV, v_off_fin = 636.115 uV 13:24:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -516.001 uVs 13:24:41 Integrated Voltage Measurement... 13:24:50 Voltage Offset Correction: v_off_ini = 634.422 uV, v_off_fin = 638.767 uV 13:24:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.838 uVs 13:24:50 Integrated Voltage Measurement... 13:24:59 Voltage Offset Correction: v_off_ini = 652.373 uV, v_off_fin = 644.079 uV 13:24:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -531.983 uVs 13:24:59 Integrated Voltage Measurement... 13:25:08 Voltage Offset Correction: v_off_ini = 656.074 uV, v_off_fin = 654.182 uV 13:25:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 511.283 uVs 13:25:08 Integrated Voltage Measurement... 13:25:17 Voltage Offset Correction: v_off_ini = 648.955 uV, v_off_fin = 639.163 uV 13:25:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.372 uVs 13:25:17 Integrated Voltage Measurement... 13:25:26 Voltage Offset Correction: v_off_ini = 638.291 uV, v_off_fin = 639.159 uV 13:25:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.916 uVs 13:25:29 I2Y Average and RMS of Measurements VT = -516.565 +- 3.656 uVs I2Y = -47.524 +- 0.336 uTm^2 13:25:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:25:41 Integrated Voltage Measurement... 13:25:50 Voltage Offset Correction: v_off_ini = 642.285 uV, v_off_fin = 638.328 uV 13:25:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -69.914 uVs 13:25:50 Integrated Voltage Measurement... 13:25:59 Voltage Offset Correction: v_off_ini = 643.597 uV, v_off_fin = 646.967 uV 13:25:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.730 uVs 13:25:59 Integrated Voltage Measurement... 13:26:08 Voltage Offset Correction: v_off_ini = 640.844 uV, v_off_fin = 627.301 uV 13:26:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.092 uVs 13:26:08 Integrated Voltage Measurement... 13:26:17 Voltage Offset Correction: v_off_ini = 624.473 uV, v_off_fin = 614.110 uV 13:26:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.162 uVs 13:26:17 Integrated Voltage Measurement... 13:26:26 Voltage Offset Correction: v_off_ini = 603.975 uV, v_off_fin = 614.140 uV 13:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.685 uVs 13:26:26 Integrated Voltage Measurement... 13:26:35 Voltage Offset Correction: v_off_ini = 613.813 uV, v_off_fin = 612.553 uV 13:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.550 uVs 13:26:39 I1X Average and RMS of Measurements VT = -57.189 +- 5.374 uVs I1X = 11.439 +- 1.074 uTm 13:26:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:26:46 Integrated Voltage Measurement... 13:26:55 Voltage Offset Correction: v_off_ini = 700.083 uV, v_off_fin = 608.866 uV 13:26:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.145 uVs 13:26:55 Integrated Voltage Measurement... 13:27:04 Voltage Offset Correction: v_off_ini = 629.003 uV, v_off_fin = 645.419 uV 13:27:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.346 uVs 13:27:04 Integrated Voltage Measurement... 13:27:13 Voltage Offset Correction: v_off_ini = 624.429 uV, v_off_fin = 622.767 uV 13:27:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.546 uVs 13:27:13 Integrated Voltage Measurement... 13:27:22 Voltage Offset Correction: v_off_ini = 626.369 uV, v_off_fin = 627.171 uV 13:27:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.416 uVs 13:27:22 Integrated Voltage Measurement... 13:27:31 Voltage Offset Correction: v_off_ini = 625.353 uV, v_off_fin = 633.613 uV 13:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.161 uVs 13:27:31 Integrated Voltage Measurement... 13:27:40 Voltage Offset Correction: v_off_ini = 629.992 uV, v_off_fin = 641.636 uV 13:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.056 uVs 13:27:44 I1Y Average and RMS of Measurements VT = -189.612 +- 7.734 uVs I1Y = -37.922 +- 1.547 uTm 13:27:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:27:49 Integrated Voltage Measurement... 13:27:58 Voltage Offset Correction: v_off_ini = 619.912 uV, v_off_fin = 619.562 uV 13:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 7.409 uVs 13:27:58 Integrated Voltage Measurement... 13:28:07 Voltage Offset Correction: v_off_ini = 633.572 uV, v_off_fin = 639.435 uV 13:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.829 uVs 13:28:07 Integrated Voltage Measurement... 13:28:16 Voltage Offset Correction: v_off_ini = 624.684 uV, v_off_fin = 638.230 uV 13:28:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.856 uVs 13:28:16 Integrated Voltage Measurement... 13:28:25 Voltage Offset Correction: v_off_ini = 639.880 uV, v_off_fin = 653.982 uV 13:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.279 uVs 13:28:25 Integrated Voltage Measurement... 13:28:34 Voltage Offset Correction: v_off_ini = 647.545 uV, v_off_fin = 634.021 uV 13:28:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.081 uVs 13:28:34 Integrated Voltage Measurement... 13:28:43 Voltage Offset Correction: v_off_ini = 631.049 uV, v_off_fin = 637.467 uV 13:28:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.010 uVs 13:28:46 I2X Average and RMS of Measurements VT = -22.608 +- 10.162 uVs I2X = 2.080 +- 0.935 uTm^2 13:28:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:28:51 Integrated Voltage Measurement... 13:29:00 Voltage Offset Correction: v_off_ini = 627.435 uV, v_off_fin = 623.683 uV 13:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.770 uVs 13:29:00 Integrated Voltage Measurement... 13:29:09 Voltage Offset Correction: v_off_ini = 626.450 uV, v_off_fin = 619.028 uV 13:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.951 uVs 13:29:09 Integrated Voltage Measurement... 13:29:18 Voltage Offset Correction: v_off_ini = 624.728 uV, v_off_fin = 623.095 uV 13:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.361 uVs 13:29:18 Integrated Voltage Measurement... 13:29:27 Voltage Offset Correction: v_off_ini = 620.039 uV, v_off_fin = 622.553 uV 13:29:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.862 uVs 13:29:27 Integrated Voltage Measurement... 13:29:36 Voltage Offset Correction: v_off_ini = 615.346 uV, v_off_fin = 616.481 uV 13:29:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -511.779 uVs 13:29:36 Integrated Voltage Measurement... 13:29:45 Voltage Offset Correction: v_off_ini = 607.813 uV, v_off_fin = 619.031 uV 13:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.814 uVs 13:29:48 I2Y Average and RMS of Measurements VT = -506.090 +- 4.720 uVs I2Y = -46.561 +- 0.435 uTm^2 13:29:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:29:56 Integrated Voltage Measurement... 13:30:05 Voltage Offset Correction: v_off_ini = 623.899 uV, v_off_fin = 609.184 uV 13:30:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -78.478 uVs 13:30:05 Integrated Voltage Measurement... 13:30:14 Voltage Offset Correction: v_off_ini = 607.922 uV, v_off_fin = 618.642 uV 13:30:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.029 uVs 13:30:14 Integrated Voltage Measurement... 13:30:23 Voltage Offset Correction: v_off_ini = 610.650 uV, v_off_fin = 608.984 uV 13:30:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.110 uVs 13:30:23 Integrated Voltage Measurement... 13:30:32 Voltage Offset Correction: v_off_ini = 597.390 uV, v_off_fin = 608.616 uV 13:30:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.434 uVs 13:30:32 Integrated Voltage Measurement... 13:30:41 Voltage Offset Correction: v_off_ini = 620.740 uV, v_off_fin = 611.848 uV 13:30:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.129 uVs 13:30:41 Integrated Voltage Measurement... 13:30:50 Voltage Offset Correction: v_off_ini = 614.859 uV, v_off_fin = 625.251 uV 13:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.065 uVs 13:30:54 I1X Average and RMS of Measurements VT = -58.041 +- 4.287 uVs I1X = 11.609 +- 0.857 uTm 13:30:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:31:01 Integrated Voltage Measurement... 13:31:10 Voltage Offset Correction: v_off_ini = 622.388 uV, v_off_fin = 616.720 uV 13:31:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.108 uVs 13:31:10 Integrated Voltage Measurement... 13:31:19 Voltage Offset Correction: v_off_ini = 628.410 uV, v_off_fin = 640.884 uV 13:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.850 uVs 13:31:19 Integrated Voltage Measurement... 13:31:28 Voltage Offset Correction: v_off_ini = 630.559 uV, v_off_fin = 601.990 uV 13:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.461 uVs 13:31:28 Integrated Voltage Measurement... 13:31:37 Voltage Offset Correction: v_off_ini = 635.368 uV, v_off_fin = 644.237 uV 13:31:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.182 uVs 13:31:37 Integrated Voltage Measurement... 13:31:46 Voltage Offset Correction: v_off_ini = 642.076 uV, v_off_fin = 607.981 uV 13:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.908 uVs 13:31:46 Integrated Voltage Measurement... 13:31:55 Voltage Offset Correction: v_off_ini = 614.385 uV, v_off_fin = 617.326 uV 13:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.255 uVs 13:31:59 I1Y Average and RMS of Measurements VT = -192.794 +- 7.146 uVs I1Y = -38.559 +- 1.429 uTm 13:32:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:32:04 Integrated Voltage Measurement... 13:32:13 Voltage Offset Correction: v_off_ini = 616.152 uV, v_off_fin = 628.872 uV 13:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.447 uVs 13:32:13 Integrated Voltage Measurement... 13:32:22 Voltage Offset Correction: v_off_ini = 638.877 uV, v_off_fin = 645.019 uV 13:32:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.160 uVs 13:32:23 Integrated Voltage Measurement... 13:32:32 Voltage Offset Correction: v_off_ini = 641.376 uV, v_off_fin = 629.987 uV 13:32:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.673 uVs 13:32:32 Integrated Voltage Measurement... 13:32:41 Voltage Offset Correction: v_off_ini = 628.260 uV, v_off_fin = 625.834 uV 13:32:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.420 uVs 13:32:41 Integrated Voltage Measurement... 13:32:50 Voltage Offset Correction: v_off_ini = 628.074 uV, v_off_fin = 612.788 uV 13:32:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.877 uVs 13:32:50 Integrated Voltage Measurement... 13:32:59 Voltage Offset Correction: v_off_ini = 612.556 uV, v_off_fin = 624.287 uV 13:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.105 uVs 13:33:01 I2X Average and RMS of Measurements VT = -28.114 +- 8.659 uVs I2X = 2.586 +- 0.797 uTm^2 13:33:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:33:06 Integrated Voltage Measurement... 13:33:15 Voltage Offset Correction: v_off_ini = 636.633 uV, v_off_fin = 633.677 uV 13:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -520.710 uVs 13:33:15 Integrated Voltage Measurement... 13:33:24 Voltage Offset Correction: v_off_ini = 622.259 uV, v_off_fin = 631.043 uV 13:33:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 525.155 uVs 13:33:24 Integrated Voltage Measurement... 13:33:33 Voltage Offset Correction: v_off_ini = 624.034 uV, v_off_fin = 622.411 uV 13:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -519.681 uVs 13:33:33 Integrated Voltage Measurement... 13:33:42 Voltage Offset Correction: v_off_ini = 607.024 uV, v_off_fin = 627.339 uV 13:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 525.902 uVs 13:33:42 Integrated Voltage Measurement... 13:33:51 Voltage Offset Correction: v_off_ini = 631.652 uV, v_off_fin = 636.541 uV 13:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -505.043 uVs 13:33:51 Integrated Voltage Measurement... 13:34:00 Voltage Offset Correction: v_off_ini = 637.378 uV, v_off_fin = 630.319 uV 13:34:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.428 uVs 13:34:03 I2Y Average and RMS of Measurements VT = -515.153 +- 10.902 uVs I2Y = -47.395 +- 1.004 uTm^2 13:34:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:11 Integrated Voltage Measurement... 13:34:20 Voltage Offset Correction: v_off_ini = 649.661 uV, v_off_fin = 632.447 uV 13:34:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.062 uVs 13:34:20 Integrated Voltage Measurement... 13:34:29 Voltage Offset Correction: v_off_ini = 627.038 uV, v_off_fin = 616.286 uV 13:34:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.647 uVs 13:34:29 Integrated Voltage Measurement... 13:34:38 Voltage Offset Correction: v_off_ini = 618.958 uV, v_off_fin = 629.943 uV 13:34:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.885 uVs 13:34:38 Integrated Voltage Measurement... 13:34:47 Voltage Offset Correction: v_off_ini = 639.357 uV, v_off_fin = 638.700 uV 13:34:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.197 uVs 13:34:47 Integrated Voltage Measurement... 13:34:56 Voltage Offset Correction: v_off_ini = 639.073 uV, v_off_fin = 632.536 uV 13:34:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.681 uVs 13:34:56 Integrated Voltage Measurement... 13:35:05 Voltage Offset Correction: v_off_ini = 641.303 uV, v_off_fin = 639.213 uV 13:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.299 uVs 13:35:10 I1X Average and RMS of Measurements VT = -62.295 +- 5.479 uVs I1X = 12.459 +- 1.096 uTm 13:35:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:16 Integrated Voltage Measurement... 13:35:25 Voltage Offset Correction: v_off_ini = 628.454 uV, v_off_fin = 633.388 uV 13:35:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.155 uVs 13:35:25 Integrated Voltage Measurement... 13:35:34 Voltage Offset Correction: v_off_ini = 634.188 uV, v_off_fin = 641.589 uV 13:35:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.869 uVs 13:35:34 Integrated Voltage Measurement... 13:35:43 Voltage Offset Correction: v_off_ini = 627.956 uV, v_off_fin = 615.122 uV 13:35:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.128 uVs 13:35:43 Integrated Voltage Measurement... 13:35:52 Voltage Offset Correction: v_off_ini = 628.438 uV, v_off_fin = 635.216 uV 13:35:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.937 uVs 13:35:52 Integrated Voltage Measurement... 13:36:01 Voltage Offset Correction: v_off_ini = 644.045 uV, v_off_fin = 630.307 uV 13:36:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.005 uVs 13:36:01 Integrated Voltage Measurement... 13:36:10 Voltage Offset Correction: v_off_ini = 628.323 uV, v_off_fin = 635.398 uV 13:36:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.979 uVs 13:36:15 I1Y Average and RMS of Measurements VT = -188.679 +- 1.857 uVs I1Y = -37.736 +- 0.371 uTm 13:36:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:20 Integrated Voltage Measurement... 13:36:29 Voltage Offset Correction: v_off_ini = 621.126 uV, v_off_fin = 633.274 uV 13:36:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -40.165 uVs 13:36:29 Integrated Voltage Measurement... 13:36:38 Voltage Offset Correction: v_off_ini = 640.154 uV, v_off_fin = 639.694 uV 13:36:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.705 uVs 13:36:38 Integrated Voltage Measurement... 13:36:47 Voltage Offset Correction: v_off_ini = 649.898 uV, v_off_fin = 635.285 uV 13:36:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.801 uVs 13:36:47 Integrated Voltage Measurement... 13:36:56 Voltage Offset Correction: v_off_ini = 654.252 uV, v_off_fin = 640.975 uV 13:36:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.249 uVs 13:36:56 Integrated Voltage Measurement... 13:37:05 Voltage Offset Correction: v_off_ini = 637.266 uV, v_off_fin = 624.283 uV 13:37:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.233 uVs 13:37:05 Integrated Voltage Measurement... 13:37:14 Voltage Offset Correction: v_off_ini = 644.068 uV, v_off_fin = 640.483 uV 13:37:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.179 uVs 13:37:16 I2X Average and RMS of Measurements VT = -34.722 +- 6.033 uVs I2X = 3.194 +- 0.555 uTm^2 13:37:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:21 Integrated Voltage Measurement... 13:37:30 Voltage Offset Correction: v_off_ini = 646.330 uV, v_off_fin = 637.528 uV 13:37:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.107 uVs 13:37:30 Integrated Voltage Measurement... 13:37:39 Voltage Offset Correction: v_off_ini = 636.162 uV, v_off_fin = 621.313 uV 13:37:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 505.255 uVs 13:37:40 Integrated Voltage Measurement... 13:37:48 Voltage Offset Correction: v_off_ini = 636.926 uV, v_off_fin = 624.151 uV 13:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -524.606 uVs 13:37:49 Integrated Voltage Measurement... 13:37:58 Voltage Offset Correction: v_off_ini = 629.177 uV, v_off_fin = 631.683 uV 13:37:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.145 uVs 13:37:58 Integrated Voltage Measurement... 13:38:07 Voltage Offset Correction: v_off_ini = 633.574 uV, v_off_fin = 634.837 uV 13:38:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.773 uVs 13:38:07 Integrated Voltage Measurement... 13:38:16 Voltage Offset Correction: v_off_ini = 638.569 uV, v_off_fin = 638.563 uV 13:38:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.920 uVs 13:38:18 I2Y Average and RMS of Measurements VT = -508.801 +- 7.831 uVs I2Y = -46.810 +- 0.720 uTm^2 13:38:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:38:26 Integrated Voltage Measurement... 13:38:35 Voltage Offset Correction: v_off_ini = 638.269 uV, v_off_fin = 632.214 uV 13:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -71.456 uVs 13:38:35 Integrated Voltage Measurement... 13:38:44 Voltage Offset Correction: v_off_ini = 623.747 uV, v_off_fin = 634.144 uV 13:38:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.637 uVs 13:38:44 Integrated Voltage Measurement... 13:38:53 Voltage Offset Correction: v_off_ini = 639.290 uV, v_off_fin = 628.507 uV 13:38:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.040 uVs 13:38:53 Integrated Voltage Measurement... 13:39:02 Voltage Offset Correction: v_off_ini = 644.702 uV, v_off_fin = 654.311 uV 13:39:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.502 uVs 13:39:02 Integrated Voltage Measurement... 13:39:11 Voltage Offset Correction: v_off_ini = 650.488 uV, v_off_fin = 647.409 uV 13:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.135 uVs 13:39:11 Integrated Voltage Measurement... 13:39:20 Voltage Offset Correction: v_off_ini = 643.118 uV, v_off_fin = 642.041 uV 13:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.924 uVs 13:39:25 I1X Average and RMS of Measurements VT = -62.116 +- 10.582 uVs I1X = 12.423 +- 2.117 uTm 13:39:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:39:31 Integrated Voltage Measurement... 13:39:40 Voltage Offset Correction: v_off_ini = 624.022 uV, v_off_fin = 617.321 uV 13:39:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.091 uVs 13:39:40 Integrated Voltage Measurement... 13:39:49 Voltage Offset Correction: v_off_ini = 628.835 uV, v_off_fin = 638.865 uV 13:39:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.349 uVs 13:39:49 Integrated Voltage Measurement... 13:39:58 Voltage Offset Correction: v_off_ini = 612.203 uV, v_off_fin = 614.639 uV 13:39:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.256 uVs 13:39:58 Integrated Voltage Measurement... 13:40:07 Voltage Offset Correction: v_off_ini = 616.256 uV, v_off_fin = 616.355 uV 13:40:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.727 uVs 13:40:07 Integrated Voltage Measurement... 13:40:16 Voltage Offset Correction: v_off_ini = 617.535 uV, v_off_fin = 603.850 uV 13:40:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.691 uVs 13:40:16 Integrated Voltage Measurement... 13:40:25 Voltage Offset Correction: v_off_ini = 608.757 uV, v_off_fin = 624.046 uV 13:40:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.809 uVs 13:40:29 I1Y Average and RMS of Measurements VT = -189.654 +- 3.710 uVs I1Y = -37.930 +- 0.742 uTm 13:40:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:40:35 Integrated Voltage Measurement... 13:40:44 Voltage Offset Correction: v_off_ini = 616.154 uV, v_off_fin = 620.138 uV 13:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.133 uVs 13:40:44 Integrated Voltage Measurement... 13:40:53 Voltage Offset Correction: v_off_ini = 634.124 uV, v_off_fin = 639.493 uV 13:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.083 uVs 13:40:53 Integrated Voltage Measurement... 13:41:02 Voltage Offset Correction: v_off_ini = 622.306 uV, v_off_fin = 605.434 uV 13:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.833 uVs 13:41:02 Integrated Voltage Measurement... 13:41:11 Voltage Offset Correction: v_off_ini = 616.955 uV, v_off_fin = 622.936 uV 13:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.490 uVs 13:41:11 Integrated Voltage Measurement... 13:41:20 Voltage Offset Correction: v_off_ini = 623.665 uV, v_off_fin = 610.278 uV 13:41:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.741 uVs 13:41:20 Integrated Voltage Measurement... 13:41:29 Voltage Offset Correction: v_off_ini = 610.617 uV, v_off_fin = 613.588 uV 13:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.248 uVs 13:41:31 I2X Average and RMS of Measurements VT = -24.421 +- 4.465 uVs I2X = 2.247 +- 0.411 uTm^2 13:41:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:41:36 Integrated Voltage Measurement... 13:41:45 Voltage Offset Correction: v_off_ini = 617.358 uV, v_off_fin = 608.166 uV 13:41:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -542.767 uVs 13:41:45 Integrated Voltage Measurement... 13:41:54 Voltage Offset Correction: v_off_ini = 622.170 uV, v_off_fin = 611.774 uV 13:41:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.458 uVs 13:41:54 Integrated Voltage Measurement... 13:42:03 Voltage Offset Correction: v_off_ini = 616.660 uV, v_off_fin = 611.593 uV 13:42:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.259 uVs 13:42:03 Integrated Voltage Measurement... 13:42:12 Voltage Offset Correction: v_off_ini = 593.087 uV, v_off_fin = 602.025 uV 13:42:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 529.381 uVs 13:42:12 Integrated Voltage Measurement... 13:42:21 Voltage Offset Correction: v_off_ini = 600.248 uV, v_off_fin = 603.470 uV 13:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.860 uVs 13:42:21 Integrated Voltage Measurement... 13:42:30 Voltage Offset Correction: v_off_ini = 607.512 uV, v_off_fin = 607.583 uV 13:42:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 517.102 uVs 13:42:33 I2Y Average and RMS of Measurements VT = -518.304 +- 8.707 uVs I2Y = -47.684 +- 0.801 uTm^2 13:42:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:42:41 Integrated Voltage Measurement... 13:42:50 Voltage Offset Correction: v_off_ini = 596.620 uV, v_off_fin = 602.820 uV 13:42:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -58.393 uVs 13:42:50 Integrated Voltage Measurement... 13:42:59 Voltage Offset Correction: v_off_ini = 608.059 uV, v_off_fin = 606.081 uV 13:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.524 uVs 13:42:59 Integrated Voltage Measurement... 13:43:08 Voltage Offset Correction: v_off_ini = 606.773 uV, v_off_fin = 594.586 uV 13:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.010 uVs 13:43:08 Integrated Voltage Measurement... 13:43:17 Voltage Offset Correction: v_off_ini = 603.494 uV, v_off_fin = 613.279 uV 13:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.700 uVs 13:43:17 Integrated Voltage Measurement... 13:43:26 Voltage Offset Correction: v_off_ini = 606.059 uV, v_off_fin = 605.311 uV 13:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.006 uVs 13:43:26 Integrated Voltage Measurement... 13:43:35 Voltage Offset Correction: v_off_ini = 609.250 uV, v_off_fin = 614.780 uV 13:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.083 uVs 13:43:39 I1X Average and RMS of Measurements VT = -64.453 +- 4.688 uVs I1X = 12.891 +- 0.937 uTm 13:43:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:43:46 Integrated Voltage Measurement... 13:43:55 Voltage Offset Correction: v_off_ini = 608.800 uV, v_off_fin = 592.084 uV 13:43:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.668 uVs 13:43:55 Integrated Voltage Measurement... 13:44:04 Voltage Offset Correction: v_off_ini = 623.170 uV, v_off_fin = 633.221 uV 13:44:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.169 uVs 13:44:04 Integrated Voltage Measurement... 13:44:13 Voltage Offset Correction: v_off_ini = 626.703 uV, v_off_fin = 624.255 uV 13:44:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.251 uVs 13:44:13 Integrated Voltage Measurement... 13:44:22 Voltage Offset Correction: v_off_ini = 627.734 uV, v_off_fin = 639.317 uV 13:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.929 uVs 13:44:22 Integrated Voltage Measurement... 13:44:31 Voltage Offset Correction: v_off_ini = 644.751 uV, v_off_fin = 632.071 uV 13:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.152 uVs 13:44:31 Integrated Voltage Measurement... 13:44:40 Voltage Offset Correction: v_off_ini = 641.598 uV, v_off_fin = 656.777 uV 13:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.441 uVs 13:44:44 I1Y Average and RMS of Measurements VT = -180.435 +- 8.774 uVs I1Y = -36.085 +- 1.753 uTm 13:44:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:44:49 Integrated Voltage Measurement... 13:44:58 Voltage Offset Correction: v_off_ini = 638.316 uV, v_off_fin = 633.490 uV 13:44:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.694 uVs 13:44:58 Integrated Voltage Measurement... 13:45:07 Voltage Offset Correction: v_off_ini = 647.356 uV, v_off_fin = 650.361 uV 13:45:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.163 uVs 13:45:07 Integrated Voltage Measurement... 13:45:16 Voltage Offset Correction: v_off_ini = 632.845 uV, v_off_fin = 618.503 uV 13:45:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -14.998 uVs 13:45:16 Integrated Voltage Measurement... 13:45:25 Voltage Offset Correction: v_off_ini = 632.026 uV, v_off_fin = 646.671 uV 13:45:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.641 uVs 13:45:25 Integrated Voltage Measurement... 13:45:34 Voltage Offset Correction: v_off_ini = 640.728 uV, v_off_fin = 631.814 uV 13:45:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.271 uVs 13:45:34 Integrated Voltage Measurement... 13:45:43 Voltage Offset Correction: v_off_ini = 636.949 uV, v_off_fin = 645.801 uV 13:45:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 56.188 uVs 13:45:46 I2X Average and RMS of Measurements VT = -21.659 +- 13.192 uVs I2X = 1.993 +- 1.214 uTm^2 13:45:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:45:51 Integrated Voltage Measurement... 13:46:00 Voltage Offset Correction: v_off_ini = 644.086 uV, v_off_fin = 639.879 uV 13:46:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.951 uVs 13:46:00 Integrated Voltage Measurement... 13:46:09 Voltage Offset Correction: v_off_ini = 648.786 uV, v_off_fin = 649.772 uV 13:46:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.393 uVs 13:46:09 Integrated Voltage Measurement... 13:46:18 Voltage Offset Correction: v_off_ini = 652.174 uV, v_off_fin = 648.549 uV 13:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.386 uVs 13:46:18 Integrated Voltage Measurement... 13:46:27 Voltage Offset Correction: v_off_ini = 640.973 uV, v_off_fin = 649.524 uV 13:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 528.897 uVs 13:46:27 Integrated Voltage Measurement... 13:46:36 Voltage Offset Correction: v_off_ini = 647.160 uV, v_off_fin = 651.071 uV 13:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.095 uVs 13:46:36 Integrated Voltage Measurement... 13:46:45 Voltage Offset Correction: v_off_ini = 653.827 uV, v_off_fin = 655.781 uV 13:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.919 uVs 13:46:47 I2Y Average and RMS of Measurements VT = -513.773 +- 6.199 uVs I2Y = -47.267 +- 0.570 uTm^2 13:47:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:47:08 Integrated Voltage Measurement... 13:47:16 Voltage Offset Correction: v_off_ini = 660.021 uV, v_off_fin = 643.081 uV 13:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -91.672 uVs 13:47:17 Integrated Voltage Measurement... 13:47:25 Voltage Offset Correction: v_off_ini = 640.820 uV, v_off_fin = 633.222 uV 13:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.903 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = 640.849 uV, v_off_fin = 644.088 uV 13:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.669 uVs 13:47:35 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = 629.078 uV, v_off_fin = 641.844 uV 13:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.645 uVs 13:47:44 Integrated Voltage Measurement... 13:47:53 Voltage Offset Correction: v_off_ini = 639.140 uV, v_off_fin = 638.041 uV 13:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.166 uVs 13:47:53 Integrated Voltage Measurement... 13:48:02 Voltage Offset Correction: v_off_ini = 628.770 uV, v_off_fin = 637.700 uV 13:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.338 uVs 13:48:06 I1X Average and RMS of Measurements VT = -83.232 +- 5.786 uVs I1X = 16.647 +- 1.157 uTm 13:48:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:48:13 Integrated Voltage Measurement... 13:48:21 Voltage Offset Correction: v_off_ini = 631.405 uV, v_off_fin = 618.406 uV 13:48:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -200.127 uVs 13:48:22 Integrated Voltage Measurement... 13:48:30 Voltage Offset Correction: v_off_ini = 643.573 uV, v_off_fin = 654.315 uV 13:48:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.305 uVs 13:48:31 Integrated Voltage Measurement... 13:48:39 Voltage Offset Correction: v_off_ini = 644.038 uV, v_off_fin = 631.522 uV 13:48:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.205 uVs 13:48:40 Integrated Voltage Measurement... 13:48:48 Voltage Offset Correction: v_off_ini = 629.567 uV, v_off_fin = 647.270 uV 13:48:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.797 uVs 13:48:49 Integrated Voltage Measurement... 13:48:57 Voltage Offset Correction: v_off_ini = 644.781 uV, v_off_fin = 629.266 uV 13:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.965 uVs 13:48:58 Integrated Voltage Measurement... 13:49:06 Voltage Offset Correction: v_off_ini = 637.615 uV, v_off_fin = 641.107 uV 13:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.369 uVs 13:49:11 I1Y Average and RMS of Measurements VT = -211.795 +- 7.274 uVs I1Y = -42.360 +- 1.454 uTm 13:49:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:49:18 Integrated Voltage Measurement... 13:49:27 Voltage Offset Correction: v_off_ini = 646.605 uV, v_off_fin = 631.521 uV 13:49:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.582 uVs 13:49:27 Integrated Voltage Measurement... 13:49:36 Voltage Offset Correction: v_off_ini = 635.746 uV, v_off_fin = 636.876 uV 13:49:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 40.137 uVs 13:49:37 Integrated Voltage Measurement... 13:49:46 Voltage Offset Correction: v_off_ini = 622.505 uV, v_off_fin = 627.404 uV 13:49:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.470 uVs 13:49:46 Integrated Voltage Measurement... 13:49:55 Voltage Offset Correction: v_off_ini = 640.639 uV, v_off_fin = 645.436 uV 13:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.937 uVs 13:49:55 Integrated Voltage Measurement... 13:50:04 Voltage Offset Correction: v_off_ini = 650.498 uV, v_off_fin = 632.986 uV 13:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.753 uVs 13:50:04 Integrated Voltage Measurement... 13:50:13 Voltage Offset Correction: v_off_ini = 659.462 uV, v_off_fin = 650.553 uV 13:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.448 uVs 13:50:15 I2X Average and RMS of Measurements VT = -42.888 +- 3.820 uVs I2X = 3.946 +- 0.351 uTm^2 13:50:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:50:23 Integrated Voltage Measurement... 13:50:32 Voltage Offset Correction: v_off_ini = 649.456 uV, v_off_fin = 643.932 uV 13:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -530.512 uVs 13:50:32 Integrated Voltage Measurement... 13:50:41 Voltage Offset Correction: v_off_ini = 640.437 uV, v_off_fin = 642.836 uV 13:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.344 uVs 13:50:41 Integrated Voltage Measurement... 13:50:50 Voltage Offset Correction: v_off_ini = 645.776 uV, v_off_fin = 652.736 uV 13:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -531.996 uVs 13:50:50 Integrated Voltage Measurement... 13:50:59 Voltage Offset Correction: v_off_ini = 654.896 uV, v_off_fin = 645.870 uV 13:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.818 uVs 13:50:59 Integrated Voltage Measurement... 13:51:08 Voltage Offset Correction: v_off_ini = 651.753 uV, v_off_fin = 642.815 uV 13:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -532.468 uVs 13:51:08 Integrated Voltage Measurement... 13:51:17 Voltage Offset Correction: v_off_ini = 647.569 uV, v_off_fin = 636.174 uV 13:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 530.124 uVs 13:51:19 I2Y Average and RMS of Measurements VT = -525.377 +- 4.845 uVs I2Y = -48.335 +- 0.446 uTm^2 13:51:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:51:28 Integrated Voltage Measurement... 13:51:37 Voltage Offset Correction: v_off_ini = 642.686 uV, v_off_fin = 638.240 uV 13:51:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.215 uVs 13:51:37 Integrated Voltage Measurement... 13:51:46 Voltage Offset Correction: v_off_ini = 642.608 uV, v_off_fin = 650.459 uV 13:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.607 uVs 13:51:46 Integrated Voltage Measurement... 13:51:55 Voltage Offset Correction: v_off_ini = 638.578 uV, v_off_fin = 638.541 uV 13:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -56.726 uVs 13:51:55 Integrated Voltage Measurement... 13:52:04 Voltage Offset Correction: v_off_ini = 639.482 uV, v_off_fin = 640.146 uV 13:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.798 uVs 13:52:04 Integrated Voltage Measurement... 13:52:13 Voltage Offset Correction: v_off_ini = 642.700 uV, v_off_fin = 630.517 uV 13:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.604 uVs 13:52:14 Integrated Voltage Measurement... 13:52:22 Voltage Offset Correction: v_off_ini = 645.258 uV, v_off_fin = 640.289 uV 13:52:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.261 uVs 13:52:27 I1X Average and RMS of Measurements VT = -68.368 +- 8.907 uVs I1X = 13.674 +- 1.781 uTm 13:52:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:52:34 Integrated Voltage Measurement... 13:52:42 Voltage Offset Correction: v_off_ini = 649.185 uV, v_off_fin = 630.882 uV 13:52:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.594 uVs 13:52:43 Integrated Voltage Measurement... 13:52:51 Voltage Offset Correction: v_off_ini = 636.841 uV, v_off_fin = 639.216 uV 13:52:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.932 uVs 13:52:52 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = 647.754 uV, v_off_fin = 631.235 uV 13:53:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.883 uVs 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = 636.115 uV, v_off_fin = 647.023 uV 13:53:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.603 uVs 13:53:10 Integrated Voltage Measurement... 13:53:19 Voltage Offset Correction: v_off_ini = 640.774 uV, v_off_fin = 650.135 uV 13:53:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.232 uVs 13:53:19 Integrated Voltage Measurement... 13:53:28 Voltage Offset Correction: v_off_ini = 644.107 uV, v_off_fin = 667.942 uV 13:53:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.346 uVs 13:53:32 I1Y Average and RMS of Measurements VT = -210.765 +- 4.246 uVs I1Y = -42.153 +- 0.849 uTm 13:53:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:53:40 Integrated Voltage Measurement... 13:53:49 Voltage Offset Correction: v_off_ini = 637.488 uV, v_off_fin = 633.836 uV 13:53:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -65.608 uVs 13:53:49 Integrated Voltage Measurement... 13:53:58 Voltage Offset Correction: v_off_ini = 639.187 uV, v_off_fin = 646.378 uV 13:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.983 uVs 13:53:58 Integrated Voltage Measurement... 13:54:07 Voltage Offset Correction: v_off_ini = 646.782 uV, v_off_fin = 645.543 uV 13:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.771 uVs 13:54:07 Integrated Voltage Measurement... 13:54:16 Voltage Offset Correction: v_off_ini = 643.092 uV, v_off_fin = 654.849 uV 13:54:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.548 uVs 13:54:16 Integrated Voltage Measurement... 13:54:25 Voltage Offset Correction: v_off_ini = 647.065 uV, v_off_fin = 638.795 uV 13:54:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.705 uVs 13:54:25 Integrated Voltage Measurement... 13:54:34 Voltage Offset Correction: v_off_ini = 635.719 uV, v_off_fin = 641.748 uV 13:54:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.926 uVs 13:54:36 I2X Average and RMS of Measurements VT = -52.923 +- 2.741 uVs I2X = 4.869 +- 0.252 uTm^2 13:54:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:54:44 Integrated Voltage Measurement... 13:54:53 Voltage Offset Correction: v_off_ini = 640.882 uV, v_off_fin = 639.281 uV 13:54:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -527.528 uVs 13:54:53 Integrated Voltage Measurement... 13:55:02 Voltage Offset Correction: v_off_ini = 632.855 uV, v_off_fin = 643.896 uV 13:55:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.652 uVs 13:55:02 Integrated Voltage Measurement... 13:55:11 Voltage Offset Correction: v_off_ini = 648.236 uV, v_off_fin = 638.812 uV 13:55:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -533.299 uVs 13:55:11 Integrated Voltage Measurement... 13:55:20 Voltage Offset Correction: v_off_ini = 651.808 uV, v_off_fin = 651.099 uV 13:55:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.480 uVs 13:55:20 Integrated Voltage Measurement... 13:55:29 Voltage Offset Correction: v_off_ini = 642.805 uV, v_off_fin = 649.572 uV 13:55:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -531.119 uVs 13:55:29 Integrated Voltage Measurement... 13:55:38 Voltage Offset Correction: v_off_ini = 645.518 uV, v_off_fin = 656.909 uV 13:55:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 521.108 uVs 13:55:41 I2Y Average and RMS of Measurements VT = -523.031 +- 2.461 uVs I2Y = -48.119 +- 0.226 uTm^2 13:55:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:50 Integrated Voltage Measurement... 13:55:58 Voltage Offset Correction: v_off_ini = 635.874 uV, v_off_fin = 643.286 uV 13:55:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.150 uVs 13:55:59 Integrated Voltage Measurement... 13:56:08 Voltage Offset Correction: v_off_ini = 644.863 uV, v_off_fin = 642.415 uV 13:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.133 uVs 13:56:08 Integrated Voltage Measurement... 13:56:17 Voltage Offset Correction: v_off_ini = 643.499 uV, v_off_fin = 644.099 uV 13:56:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.626 uVs 13:56:17 Integrated Voltage Measurement... 13:56:26 Voltage Offset Correction: v_off_ini = 633.825 uV, v_off_fin = 637.741 uV 13:56:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4997 mm dXY = 0.4998 mm VT = 83.241 uVs 13:56:26 Integrated Voltage Measurement... 13:56:35 Voltage Offset Correction: v_off_ini = 635.844 uV, v_off_fin = 632.076 uV 13:56:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.736 uVs 13:56:35 Integrated Voltage Measurement... 13:56:44 Voltage Offset Correction: v_off_ini = 645.236 uV, v_off_fin = 645.518 uV 13:56:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.313 uVs 13:56:48 I1X Average and RMS of Measurements VT = -76.867 +- 6.900 uVs I1X = 15.375 +- 1.380 uTm 13:56:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:55 Integrated Voltage Measurement... 13:57:04 Voltage Offset Correction: v_off_ini = 636.023 uV, v_off_fin = 622.261 uV 13:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.197 uVs 13:57:04 Integrated Voltage Measurement... 13:57:13 Voltage Offset Correction: v_off_ini = 623.366 uV, v_off_fin = 646.376 uV 13:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.418 uVs 13:57:13 Integrated Voltage Measurement... 13:57:22 Voltage Offset Correction: v_off_ini = 633.987 uV, v_off_fin = 620.157 uV 13:57:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.372 uVs 13:57:22 Integrated Voltage Measurement... 13:57:31 Voltage Offset Correction: v_off_ini = 646.776 uV, v_off_fin = 648.917 uV 13:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.001 uVs 13:57:31 Integrated Voltage Measurement... 13:57:40 Voltage Offset Correction: v_off_ini = 642.769 uV, v_off_fin = 623.677 uV 13:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.105 uVs 13:57:40 Integrated Voltage Measurement... 13:57:49 Voltage Offset Correction: v_off_ini = 629.517 uV, v_off_fin = 642.066 uV 13:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.793 uVs 13:57:53 I1Y Average and RMS of Measurements VT = -198.481 +- 6.068 uVs I1Y = -39.697 +- 1.214 uTm 13:57:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:01 Integrated Voltage Measurement... 13:58:10 Voltage Offset Correction: v_off_ini = 640.618 uV, v_off_fin = 633.004 uV 13:58:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.005 uVs 13:58:10 Integrated Voltage Measurement... 13:58:19 Voltage Offset Correction: v_off_ini = 635.850 uV, v_off_fin = 646.612 uV 13:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.416 uVs 13:58:19 Integrated Voltage Measurement... 13:58:28 Voltage Offset Correction: v_off_ini = 629.648 uV, v_off_fin = 628.517 uV 13:58:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -52.997 uVs 13:58:28 Integrated Voltage Measurement... 13:58:37 Voltage Offset Correction: v_off_ini = 661.936 uV, v_off_fin = 655.872 uV 13:58:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.216 uVs 13:58:37 Integrated Voltage Measurement... 13:58:46 Voltage Offset Correction: v_off_ini = 658.663 uV, v_off_fin = 646.903 uV 13:58:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.708 uVs 13:58:46 Integrated Voltage Measurement... 13:58:55 Voltage Offset Correction: v_off_ini = 629.892 uV, v_off_fin = 652.873 uV 13:58:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.873 uVs 13:58:57 I2X Average and RMS of Measurements VT = -43.703 +- 1.347 uVs I2X = 4.021 +- 0.124 uTm^2 13:59:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:05 Integrated Voltage Measurement... 13:59:14 Voltage Offset Correction: v_off_ini = 660.497 uV, v_off_fin = 652.123 uV 13:59:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -523.267 uVs 13:59:14 Integrated Voltage Measurement... 13:59:23 Voltage Offset Correction: v_off_ini = 642.369 uV, v_off_fin = 654.178 uV 13:59:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.250 uVs 13:59:23 Integrated Voltage Measurement... 13:59:32 Voltage Offset Correction: v_off_ini = 645.899 uV, v_off_fin = 657.620 uV 13:59:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.272 uVs 13:59:32 Integrated Voltage Measurement... 13:59:41 Voltage Offset Correction: v_off_ini = 644.523 uV, v_off_fin = 644.201 uV 13:59:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 517.612 uVs 13:59:41 Integrated Voltage Measurement... 13:59:50 Voltage Offset Correction: v_off_ini = 645.393 uV, v_off_fin = 636.924 uV 13:59:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -505.835 uVs 13:59:50 Integrated Voltage Measurement... 13:59:59 Voltage Offset Correction: v_off_ini = 652.245 uV, v_off_fin = 651.085 uV 13:59:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.442 uVs 14:00:02 I2Y Average and RMS of Measurements VT = -505.946 +- 7.110 uVs I2Y = -46.547 +- 0.654 uTm^2 14:00:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:00:11 Integrated Voltage Measurement... 14:00:20 Voltage Offset Correction: v_off_ini = 650.997 uV, v_off_fin = 649.869 uV 14:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.648 uVs 14:00:20 Integrated Voltage Measurement... 14:00:29 Voltage Offset Correction: v_off_ini = 649.862 uV, v_off_fin = 655.981 uV 14:00:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.974 uVs 14:00:29 Integrated Voltage Measurement... 14:00:38 Voltage Offset Correction: v_off_ini = 650.414 uV, v_off_fin = 641.396 uV 14:00:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.226 uVs 14:00:38 Integrated Voltage Measurement... 14:00:47 Voltage Offset Correction: v_off_ini = 652.998 uV, v_off_fin = 650.806 uV 14:00:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.276 uVs 14:00:47 Integrated Voltage Measurement... 14:00:56 Voltage Offset Correction: v_off_ini = 653.639 uV, v_off_fin = 652.541 uV 14:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.699 uVs 14:00:56 Integrated Voltage Measurement... 14:01:05 Voltage Offset Correction: v_off_ini = 661.252 uV, v_off_fin = 652.888 uV 14:01:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.125 uVs 14:01:09 I1X Average and RMS of Measurements VT = -79.158 +- 1.948 uVs I1X = 15.832 +- 0.389 uTm 14:01:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:01:16 Integrated Voltage Measurement... 14:01:25 Voltage Offset Correction: v_off_ini = 649.007 uV, v_off_fin = 639.181 uV 14:01:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -195.696 uVs 14:01:25 Integrated Voltage Measurement... 14:01:34 Voltage Offset Correction: v_off_ini = 643.674 uV, v_off_fin = 654.872 uV 14:01:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.581 uVs 14:01:34 Integrated Voltage Measurement... 14:01:43 Voltage Offset Correction: v_off_ini = 653.286 uV, v_off_fin = 638.011 uV 14:01:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.405 uVs 14:01:43 Integrated Voltage Measurement... 14:01:52 Voltage Offset Correction: v_off_ini = 651.875 uV, v_off_fin = 662.506 uV 14:01:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.562 uVs 14:01:52 Integrated Voltage Measurement... 14:02:01 Voltage Offset Correction: v_off_ini = 655.286 uV, v_off_fin = 643.124 uV 14:02:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.409 uVs 14:02:01 Integrated Voltage Measurement... 14:02:10 Voltage Offset Correction: v_off_ini = 669.595 uV, v_off_fin = 664.557 uV 14:02:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.621 uVs 14:02:14 I1Y Average and RMS of Measurements VT = -195.879 +- 4.563 uVs I1Y = -39.176 +- 0.913 uTm 14:02:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = 660.646 uV, v_off_fin = 661.121 uV 14:02:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -50.682 uVs 14:02:31 Integrated Voltage Measurement... 14:02:40 Voltage Offset Correction: v_off_ini = 657.707 uV, v_off_fin = 665.576 uV 14:02:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.977 uVs 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = 646.987 uV, v_off_fin = 643.569 uV 14:02:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.697 uVs 14:02:49 Integrated Voltage Measurement... 14:02:58 Voltage Offset Correction: v_off_ini = 643.613 uV, v_off_fin = 655.587 uV 14:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.175 uVs 14:02:58 Integrated Voltage Measurement... 14:03:07 Voltage Offset Correction: v_off_ini = 652.342 uV, v_off_fin = 644.305 uV 14:03:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.242 uVs 14:03:07 Integrated Voltage Measurement... 14:03:16 Voltage Offset Correction: v_off_ini = 651.856 uV, v_off_fin = 665.774 uV 14:03:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.682 uVs 14:03:18 I2X Average and RMS of Measurements VT = -55.742 +- 4.306 uVs I2X = 5.128 +- 0.396 uTm^2 14:03:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:03:26 Integrated Voltage Measurement... 14:03:35 Voltage Offset Correction: v_off_ini = 661.682 uV, v_off_fin = 650.678 uV 14:03:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.016 uVs 14:03:35 Integrated Voltage Measurement... 14:03:44 Voltage Offset Correction: v_off_ini = 642.685 uV, v_off_fin = 640.831 uV 14:03:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 528.113 uVs 14:03:44 Integrated Voltage Measurement... 14:03:53 Voltage Offset Correction: v_off_ini = 645.707 uV, v_off_fin = 645.814 uV 14:03:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -525.505 uVs 14:03:53 Integrated Voltage Measurement... 14:04:02 Voltage Offset Correction: v_off_ini = 640.268 uV, v_off_fin = 639.453 uV 14:04:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 515.701 uVs 14:04:02 Integrated Voltage Measurement... 14:04:11 Voltage Offset Correction: v_off_ini = 630.714 uV, v_off_fin = 632.423 uV 14:04:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -517.562 uVs 14:04:11 Integrated Voltage Measurement... 14:04:20 Voltage Offset Correction: v_off_ini = 641.920 uV, v_off_fin = 640.527 uV 14:04:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 523.086 uVs 14:04:23 I2Y Average and RMS of Measurements VT = -520.330 +- 0.220 uVs I2Y = -47.871 +- 0.021 uTm^2 14:04:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:04:32 Integrated Voltage Measurement... 14:04:41 Voltage Offset Correction: v_off_ini = 641.264 uV, v_off_fin = 641.653 uV 14:04:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.579 uVs 14:04:41 Integrated Voltage Measurement... 14:04:50 Voltage Offset Correction: v_off_ini = 641.201 uV, v_off_fin = 646.643 uV 14:04:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.231 uVs 14:04:50 Integrated Voltage Measurement... 14:04:59 Voltage Offset Correction: v_off_ini = 648.200 uV, v_off_fin = 650.575 uV 14:04:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.814 uVs 14:04:59 Integrated Voltage Measurement... 14:05:08 Voltage Offset Correction: v_off_ini = 645.197 uV, v_off_fin = 653.005 uV 14:05:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.287 uVs 14:05:08 Integrated Voltage Measurement... 14:05:17 Voltage Offset Correction: v_off_ini = 660.371 uV, v_off_fin = 645.648 uV 14:05:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.315 uVs 14:05:17 Integrated Voltage Measurement... 14:05:26 Voltage Offset Correction: v_off_ini = 659.128 uV, v_off_fin = 657.855 uV 14:05:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.004 uVs 14:05:30 I1X Average and RMS of Measurements VT = -83.705 +- 1.080 uVs I1X = 16.741 +- 0.216 uTm 14:05:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:05:37 Integrated Voltage Measurement... 14:05:46 Voltage Offset Correction: v_off_ini = 656.912 uV, v_off_fin = 642.741 uV 14:05:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.209 uVs 14:05:46 Integrated Voltage Measurement... 14:05:55 Voltage Offset Correction: v_off_ini = 644.849 uV, v_off_fin = 661.094 uV 14:05:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.126 uVs 14:05:55 Integrated Voltage Measurement... 14:06:04 Voltage Offset Correction: v_off_ini = 650.907 uV, v_off_fin = 650.720 uV 14:06:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.127 uVs 14:06:04 Integrated Voltage Measurement... 14:06:13 Voltage Offset Correction: v_off_ini = 651.539 uV, v_off_fin = 664.835 uV 14:06:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.114 uVs 14:06:13 Integrated Voltage Measurement... 14:06:22 Voltage Offset Correction: v_off_ini = 656.619 uV, v_off_fin = 657.755 uV 14:06:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.228 uVs 14:06:22 Integrated Voltage Measurement... 14:06:31 Voltage Offset Correction: v_off_ini = 657.955 uV, v_off_fin = 668.076 uV 14:06:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.584 uVs 14:06:35 I1Y Average and RMS of Measurements VT = -194.231 +- 3.484 uVs I1Y = -38.846 +- 0.697 uTm 14:06:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:06:43 Integrated Voltage Measurement... 14:06:52 Voltage Offset Correction: v_off_ini = 661.310 uV, v_off_fin = 658.613 uV 14:06:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.119 uVs 14:06:52 Integrated Voltage Measurement... 14:07:01 Voltage Offset Correction: v_off_ini = 661.420 uV, v_off_fin = 671.878 uV 14:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.398 uVs 14:07:01 Integrated Voltage Measurement... 14:07:10 Voltage Offset Correction: v_off_ini = 664.762 uV, v_off_fin = 654.900 uV 14:07:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.943 uVs 14:07:10 Integrated Voltage Measurement... 14:07:19 Voltage Offset Correction: v_off_ini = 664.333 uV, v_off_fin = 674.584 uV 14:07:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.948 uVs 14:07:19 Integrated Voltage Measurement... 14:07:28 Voltage Offset Correction: v_off_ini = 668.376 uV, v_off_fin = 668.039 uV 14:07:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.458 uVs 14:07:28 Integrated Voltage Measurement... 14:07:37 Voltage Offset Correction: v_off_ini = 665.516 uV, v_off_fin = 676.744 uV 14:07:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.148 uVs 14:07:40 I2X Average and RMS of Measurements VT = -55.669 +- 2.409 uVs I2X = 5.122 +- 0.222 uTm^2 14:07:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:07:47 Integrated Voltage Measurement... 14:07:56 Voltage Offset Correction: v_off_ini = 674.134 uV, v_off_fin = 667.962 uV 14:07:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.524 uVs 14:07:56 Integrated Voltage Measurement... 14:08:05 Voltage Offset Correction: v_off_ini = 677.985 uV, v_off_fin = 666.264 uV 14:08:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 510.865 uVs 14:08:05 Integrated Voltage Measurement... 14:08:14 Voltage Offset Correction: v_off_ini = 674.715 uV, v_off_fin = 679.372 uV 14:08:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.516 uVs 14:08:14 Integrated Voltage Measurement... 14:08:23 Voltage Offset Correction: v_off_ini = 668.388 uV, v_off_fin = 680.442 uV 14:08:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 526.668 uVs 14:08:23 Integrated Voltage Measurement... 14:08:32 Voltage Offset Correction: v_off_ini = 680.094 uV, v_off_fin = 673.541 uV 14:08:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -530.172 uVs 14:08:32 Integrated Voltage Measurement... 14:08:41 Voltage Offset Correction: v_off_ini = 673.362 uV, v_off_fin = 672.309 uV 14:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.071 uVs 14:08:44 I2Y Average and RMS of Measurements VT = -515.469 +- 9.526 uVs I2Y = -47.424 +- 0.875 uTm^2 14:08:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:08:56 Integrated Voltage Measurement... 14:09:05 Voltage Offset Correction: v_off_ini = 692.389 uV, v_off_fin = 695.279 uV 14:09:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.817 uVs 14:09:05 Integrated Voltage Measurement... 14:09:14 Voltage Offset Correction: v_off_ini = 687.220 uV, v_off_fin = 685.480 uV 14:09:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.171 uVs 14:09:14 Integrated Voltage Measurement... 14:09:23 Voltage Offset Correction: v_off_ini = 670.623 uV, v_off_fin = 678.088 uV 14:09:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.814 uVs 14:09:23 Integrated Voltage Measurement... 14:09:32 Voltage Offset Correction: v_off_ini = 683.127 uV, v_off_fin = 684.869 uV 14:09:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.778 uVs 14:09:32 Integrated Voltage Measurement... 14:09:41 Voltage Offset Correction: v_off_ini = 688.920 uV, v_off_fin = 670.309 uV 14:09:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.719 uVs 14:09:41 Integrated Voltage Measurement... 14:09:50 Voltage Offset Correction: v_off_ini = 686.293 uV, v_off_fin = 696.394 uV 14:09:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.767 uVs 14:09:54 I1X Average and RMS of Measurements VT = -63.678 +- 1.872 uVs I1X = 12.736 +- 0.374 uTm 14:09:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:10:01 Integrated Voltage Measurement... 14:10:10 Voltage Offset Correction: v_off_ini = 684.991 uV, v_off_fin = 676.174 uV 14:10:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.335 uVs 14:10:10 Integrated Voltage Measurement... 14:10:19 Voltage Offset Correction: v_off_ini = 662.237 uV, v_off_fin = 683.915 uV 14:10:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.226 uVs 14:10:19 Integrated Voltage Measurement... 14:10:28 Voltage Offset Correction: v_off_ini = 683.031 uV, v_off_fin = 693.557 uV 14:10:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.431 uVs 14:10:28 Integrated Voltage Measurement... 14:10:37 Voltage Offset Correction: v_off_ini = 695.268 uV, v_off_fin = 712.791 uV 14:10:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.847 uVs 14:10:37 Integrated Voltage Measurement... 14:10:46 Voltage Offset Correction: v_off_ini = 695.082 uV, v_off_fin = 675.844 uV 14:10:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.342 uVs 14:10:46 Integrated Voltage Measurement... 14:10:55 Voltage Offset Correction: v_off_ini = 693.787 uV, v_off_fin = 706.458 uV 14:10:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.404 uVs 14:10:59 I1Y Average and RMS of Measurements VT = -201.264 +- 3.946 uVs I1Y = -40.253 +- 0.789 uTm 14:11:02 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:11:04 Integrated Voltage Measurement... 14:11:13 Voltage Offset Correction: v_off_ini = 695.587 uV, v_off_fin = 688.575 uV 14:11:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.687 uVs 14:11:13 Integrated Voltage Measurement... 14:11:22 Voltage Offset Correction: v_off_ini = 696.061 uV, v_off_fin = 704.265 uV 14:11:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.515 uVs 14:11:22 Integrated Voltage Measurement... 14:11:31 Voltage Offset Correction: v_off_ini = 697.218 uV, v_off_fin = 684.712 uV 14:11:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.662 uVs 14:11:32 Integrated Voltage Measurement... 14:11:41 Voltage Offset Correction: v_off_ini = 673.459 uV, v_off_fin = 686.451 uV 14:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.878 uVs 14:11:41 Integrated Voltage Measurement... 14:11:50 Voltage Offset Correction: v_off_ini = 665.014 uV, v_off_fin = 667.767 uV 14:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.634 uVs 14:11:50 Integrated Voltage Measurement... 14:11:59 Voltage Offset Correction: v_off_ini = 678.550 uV, v_off_fin = 683.845 uV 14:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.582 uVs 14:12:01 I2X Average and RMS of Measurements VT = -40.993 +- 10.531 uVs I2X = 3.771 +- 0.969 uTm^2 14:12:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:12:06 Integrated Voltage Measurement... 14:12:15 Voltage Offset Correction: v_off_ini = 670.857 uV, v_off_fin = 675.276 uV 14:12:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.957 uVs 14:12:15 Integrated Voltage Measurement... 14:12:24 Voltage Offset Correction: v_off_ini = 676.712 uV, v_off_fin = 672.244 uV 14:12:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.772 uVs 14:12:24 Integrated Voltage Measurement... 14:12:33 Voltage Offset Correction: v_off_ini = 680.996 uV, v_off_fin = 668.423 uV 14:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.870 uVs 14:12:33 Integrated Voltage Measurement... 14:12:42 Voltage Offset Correction: v_off_ini = 681.016 uV, v_off_fin = 667.994 uV 14:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.444 uVs 14:12:42 Integrated Voltage Measurement... 14:12:51 Voltage Offset Correction: v_off_ini = 663.356 uV, v_off_fin = 670.084 uV 14:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.362 uVs 14:12:51 Integrated Voltage Measurement... 14:13:00 Voltage Offset Correction: v_off_ini = 661.206 uV, v_off_fin = 658.221 uV 14:13:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.114 uVs 14:13:03 I2Y Average and RMS of Measurements VT = -507.087 +- 3.387 uVs I2Y = -46.652 +- 0.312 uTm^2 14:13:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:13:11 Integrated Voltage Measurement... 14:13:20 Voltage Offset Correction: v_off_ini = 666.641 uV, v_off_fin = 662.645 uV 14:13:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.631 uVs 14:13:20 Integrated Voltage Measurement... 14:13:29 Voltage Offset Correction: v_off_ini = 661.658 uV, v_off_fin = 670.015 uV 14:13:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.240 uVs 14:13:29 Integrated Voltage Measurement... 14:13:38 Voltage Offset Correction: v_off_ini = 657.108 uV, v_off_fin = 655.835 uV 14:13:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.323 uVs 14:13:38 Integrated Voltage Measurement... 14:13:47 Voltage Offset Correction: v_off_ini = 667.936 uV, v_off_fin = 685.469 uV 14:13:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.388 uVs 14:13:47 Integrated Voltage Measurement... 14:13:56 Voltage Offset Correction: v_off_ini = 664.949 uV, v_off_fin = 664.967 uV 14:13:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.235 uVs 14:13:56 Integrated Voltage Measurement... 14:14:05 Voltage Offset Correction: v_off_ini = 676.113 uV, v_off_fin = 675.825 uV 14:14:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.318 uVs 14:14:10 I1X Average and RMS of Measurements VT = -66.189 +- 3.717 uVs I1X = 13.238 +- 0.743 uTm 14:14:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:14:16 Integrated Voltage Measurement... 14:14:25 Voltage Offset Correction: v_off_ini = 667.670 uV, v_off_fin = 664.006 uV 14:14:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.092 uVs 14:14:25 Integrated Voltage Measurement... 14:14:34 Voltage Offset Correction: v_off_ini = 666.258 uV, v_off_fin = 675.877 uV 14:14:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.581 uVs 14:14:34 Integrated Voltage Measurement... 14:14:43 Voltage Offset Correction: v_off_ini = 670.743 uV, v_off_fin = 651.825 uV 14:14:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.183 uVs 14:14:43 Integrated Voltage Measurement... 14:14:52 Voltage Offset Correction: v_off_ini = 655.083 uV, v_off_fin = 667.342 uV 14:14:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.415 uVs 14:14:52 Integrated Voltage Measurement... 14:15:01 Voltage Offset Correction: v_off_ini = 670.425 uV, v_off_fin = 661.921 uV 14:15:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.954 uVs 14:15:01 Integrated Voltage Measurement... 14:15:10 Voltage Offset Correction: v_off_ini = 671.657 uV, v_off_fin = 682.786 uV 14:15:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.411 uVs 14:15:15 I1Y Average and RMS of Measurements VT = -198.273 +- 0.644 uVs I1Y = -39.655 +- 0.129 uTm 14:15:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:15:20 Integrated Voltage Measurement... 14:15:29 Voltage Offset Correction: v_off_ini = 667.323 uV, v_off_fin = 658.154 uV 14:15:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -26.813 uVs 14:15:29 Integrated Voltage Measurement... 14:15:38 Voltage Offset Correction: v_off_ini = 667.375 uV, v_off_fin = 677.066 uV 14:15:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.942 uVs 14:15:38 Integrated Voltage Measurement... 14:15:47 Voltage Offset Correction: v_off_ini = 663.447 uV, v_off_fin = 649.703 uV 14:15:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.863 uVs 14:15:47 Integrated Voltage Measurement... 14:15:56 Voltage Offset Correction: v_off_ini = 663.271 uV, v_off_fin = 661.054 uV 14:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.141 uVs 14:15:56 Integrated Voltage Measurement... 14:16:05 Voltage Offset Correction: v_off_ini = 656.323 uV, v_off_fin = 657.221 uV 14:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.485 uVs 14:16:05 Integrated Voltage Measurement... 14:16:14 Voltage Offset Correction: v_off_ini = 668.601 uV, v_off_fin = 670.193 uV 14:16:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.743 uVs 14:16:16 I2X Average and RMS of Measurements VT = -45.165 +- 6.975 uVs I2X = 4.155 +- 0.642 uTm^2 14:16:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 665.500 uV, v_off_fin = 670.432 uV 14:16:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.042 uVs 14:16:31 Integrated Voltage Measurement... 14:16:40 Voltage Offset Correction: v_off_ini = 654.458 uV, v_off_fin = 662.264 uV 14:16:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.907 uVs 14:16:40 Integrated Voltage Measurement... 14:16:49 Voltage Offset Correction: v_off_ini = 652.830 uV, v_off_fin = 655.809 uV 14:16:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -527.349 uVs 14:16:49 Integrated Voltage Measurement... 14:16:58 Voltage Offset Correction: v_off_ini = 656.849 uV, v_off_fin = 660.383 uV 14:16:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 511.238 uVs 14:16:58 Integrated Voltage Measurement... 14:17:07 Voltage Offset Correction: v_off_ini = 662.167 uV, v_off_fin = 659.829 uV 14:17:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.211 uVs 14:17:07 Integrated Voltage Measurement... 14:17:16 Voltage Offset Correction: v_off_ini = 654.484 uV, v_off_fin = 658.768 uV 14:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 531.531 uVs 14:17:18 I2Y Average and RMS of Measurements VT = -517.047 +- 5.110 uVs I2Y = -47.568 +- 0.470 uTm^2 14:17:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:26 Integrated Voltage Measurement... 14:17:35 Voltage Offset Correction: v_off_ini = 654.584 uV, v_off_fin = 650.573 uV 14:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.593 uVs 14:17:35 Integrated Voltage Measurement... 14:17:44 Voltage Offset Correction: v_off_ini = 669.885 uV, v_off_fin = 679.823 uV 14:17:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.109 uVs 14:17:44 Integrated Voltage Measurement... 14:17:53 Voltage Offset Correction: v_off_ini = 664.372 uV, v_off_fin = 651.973 uV 14:17:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.029 uVs 14:17:53 Integrated Voltage Measurement... 14:18:02 Voltage Offset Correction: v_off_ini = 664.373 uV, v_off_fin = 672.886 uV 14:18:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.530 uVs 14:18:02 Integrated Voltage Measurement... 14:18:11 Voltage Offset Correction: v_off_ini = 669.999 uV, v_off_fin = 660.254 uV 14:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.144 uVs 14:18:11 Integrated Voltage Measurement... 14:18:20 Voltage Offset Correction: v_off_ini = 673.773 uV, v_off_fin = 666.073 uV 14:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.461 uVs 14:18:25 I1X Average and RMS of Measurements VT = -84.644 +- 10.511 uVs I1X = 16.929 +- 2.102 uTm 14:18:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:31 Integrated Voltage Measurement... 14:18:40 Voltage Offset Correction: v_off_ini = 656.811 uV, v_off_fin = 657.864 uV 14:18:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.360 uVs 14:18:40 Integrated Voltage Measurement... 14:18:49 Voltage Offset Correction: v_off_ini = 666.029 uV, v_off_fin = 668.353 uV 14:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.116 uVs 14:18:49 Integrated Voltage Measurement... 14:18:58 Voltage Offset Correction: v_off_ini = 663.617 uV, v_off_fin = 655.749 uV 14:18:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.826 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = 680.298 uV, v_off_fin = 676.297 uV 14:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.649 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = 665.371 uV, v_off_fin = 651.558 uV 14:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.813 uVs 14:19:16 Integrated Voltage Measurement... 14:19:25 Voltage Offset Correction: v_off_ini = 666.938 uV, v_off_fin = 679.926 uV 14:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.815 uVs 14:19:29 I1Y Average and RMS of Measurements VT = -188.096 +- 1.161 uVs I1Y = -37.619 +- 0.232 uTm 14:19:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:35 Integrated Voltage Measurement... 14:19:44 Voltage Offset Correction: v_off_ini = 671.542 uV, v_off_fin = 658.428 uV 14:19:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.731 uVs 14:19:44 Integrated Voltage Measurement... 14:19:53 Voltage Offset Correction: v_off_ini = 672.163 uV, v_off_fin = 687.724 uV 14:19:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.337 uVs 14:19:53 Integrated Voltage Measurement... 14:20:02 Voltage Offset Correction: v_off_ini = 675.002 uV, v_off_fin = 661.158 uV 14:20:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.275 uVs 14:20:02 Integrated Voltage Measurement... 14:20:11 Voltage Offset Correction: v_off_ini = 658.669 uV, v_off_fin = 676.479 uV 14:20:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.332 uVs 14:20:11 Integrated Voltage Measurement... 14:20:20 Voltage Offset Correction: v_off_ini = 671.099 uV, v_off_fin = 655.286 uV 14:20:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.824 uVs 14:20:20 Integrated Voltage Measurement... 14:20:29 Voltage Offset Correction: v_off_ini = 651.103 uV, v_off_fin = 645.520 uV 14:20:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.580 uVs 14:20:31 I2X Average and RMS of Measurements VT = -46.846 +- 9.093 uVs I2X = 4.310 +- 0.837 uTm^2 14:20:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:36 Integrated Voltage Measurement... 14:20:45 Voltage Offset Correction: v_off_ini = 669.992 uV, v_off_fin = 675.888 uV 14:20:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -519.545 uVs 14:20:45 Integrated Voltage Measurement... 14:20:54 Voltage Offset Correction: v_off_ini = 668.703 uV, v_off_fin = 671.548 uV 14:20:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.606 uVs 14:20:54 Integrated Voltage Measurement... 14:21:03 Voltage Offset Correction: v_off_ini = 653.451 uV, v_off_fin = 653.210 uV 14:21:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -523.775 uVs 14:21:03 Integrated Voltage Measurement... 14:21:12 Voltage Offset Correction: v_off_ini = 662.660 uV, v_off_fin = 656.910 uV 14:21:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.943 uVs 14:21:12 Integrated Voltage Measurement... 14:21:21 Voltage Offset Correction: v_off_ini = 657.036 uV, v_off_fin = 666.190 uV 14:21:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -522.964 uVs 14:21:21 Integrated Voltage Measurement... 14:21:30 Voltage Offset Correction: v_off_ini = 665.060 uV, v_off_fin = 663.802 uV 14:21:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 517.434 uVs 14:21:33 I2Y Average and RMS of Measurements VT = -515.711 +- 4.063 uVs I2Y = -47.445 +- 0.374 uTm^2 14:21:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:21:41 Integrated Voltage Measurement... 14:21:50 Voltage Offset Correction: v_off_ini = 676.803 uV, v_off_fin = 662.952 uV 14:21:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.332 uVs 14:21:50 Integrated Voltage Measurement... 14:21:59 Voltage Offset Correction: v_off_ini = 655.027 uV, v_off_fin = 680.333 uV 14:21:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.569 uVs 14:21:59 Integrated Voltage Measurement... 14:22:08 Voltage Offset Correction: v_off_ini = 675.577 uV, v_off_fin = 666.746 uV 14:22:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.688 uVs 14:22:08 Integrated Voltage Measurement... 14:22:17 Voltage Offset Correction: v_off_ini = 673.491 uV, v_off_fin = 678.565 uV 14:22:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.331 uVs 14:22:17 Integrated Voltage Measurement... 14:22:26 Voltage Offset Correction: v_off_ini = 668.206 uV, v_off_fin = 657.470 uV 14:22:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.101 uVs 14:22:26 Integrated Voltage Measurement... 14:22:35 Voltage Offset Correction: v_off_ini = 652.795 uV, v_off_fin = 667.586 uV 14:22:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.067 uVs 14:22:39 I1X Average and RMS of Measurements VT = -69.181 +- 4.358 uVs I1X = 13.837 +- 0.872 uTm 14:22:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:22:46 Integrated Voltage Measurement... 14:22:55 Voltage Offset Correction: v_off_ini = 662.162 uV, v_off_fin = 647.994 uV 14:22:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.144 uVs 14:22:55 Integrated Voltage Measurement... 14:23:04 Voltage Offset Correction: v_off_ini = 650.268 uV, v_off_fin = 668.531 uV 14:23:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.085 uVs 14:23:04 Integrated Voltage Measurement... 14:23:13 Voltage Offset Correction: v_off_ini = 647.375 uV, v_off_fin = 649.884 uV 14:23:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.237 uVs 14:23:13 Integrated Voltage Measurement... 14:23:22 Voltage Offset Correction: v_off_ini = 660.986 uV, v_off_fin = 658.624 uV 14:23:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.971 uVs 14:23:22 Integrated Voltage Measurement... 14:23:31 Voltage Offset Correction: v_off_ini = 666.814 uV, v_off_fin = 657.878 uV 14:23:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.852 uVs 14:23:31 Integrated Voltage Measurement... 14:23:40 Voltage Offset Correction: v_off_ini = 650.883 uV, v_off_fin = 673.415 uV 14:23:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.296 uVs 14:23:44 I1Y Average and RMS of Measurements VT = -195.598 +- 0.800 uVs I1Y = -39.118 +- 0.161 uTm 14:23:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:23:49 Integrated Voltage Measurement... 14:23:58 Voltage Offset Correction: v_off_ini = 651.381 uV, v_off_fin = 644.403 uV 14:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.149 uVs 14:23:58 Integrated Voltage Measurement... 14:24:07 Voltage Offset Correction: v_off_ini = 652.183 uV, v_off_fin = 659.516 uV 14:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.435 uVs 14:24:07 Integrated Voltage Measurement... 14:24:16 Voltage Offset Correction: v_off_ini = 646.316 uV, v_off_fin = 641.773 uV 14:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.677 uVs 14:24:16 Integrated Voltage Measurement... 14:24:25 Voltage Offset Correction: v_off_ini = 640.532 uV, v_off_fin = 650.588 uV 14:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.888 uVs 14:24:26 Integrated Voltage Measurement... 14:24:34 Voltage Offset Correction: v_off_ini = 656.216 uV, v_off_fin = 646.303 uV 14:24:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.422 uVs 14:24:35 Integrated Voltage Measurement... 14:24:44 Voltage Offset Correction: v_off_ini = 635.846 uV, v_off_fin = 647.843 uV 14:24:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.119 uVs 14:24:46 I2X Average and RMS of Measurements VT = -49.948 +- 5.445 uVs I2X = 4.595 +- 0.501 uTm^2 14:24:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:24:51 Integrated Voltage Measurement... 14:25:00 Voltage Offset Correction: v_off_ini = 644.860 uV, v_off_fin = 644.695 uV 14:25:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.700 uVs 14:25:00 Integrated Voltage Measurement... 14:25:09 Voltage Offset Correction: v_off_ini = 644.782 uV, v_off_fin = 645.206 uV 14:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 519.602 uVs 14:25:09 Integrated Voltage Measurement... 14:25:18 Voltage Offset Correction: v_off_ini = 625.982 uV, v_off_fin = 638.936 uV 14:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.193 uVs 14:25:18 Integrated Voltage Measurement... 14:25:27 Voltage Offset Correction: v_off_ini = 625.345 uV, v_off_fin = 643.175 uV 14:25:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 525.601 uVs 14:25:27 Integrated Voltage Measurement... 14:25:36 Voltage Offset Correction: v_off_ini = 646.699 uV, v_off_fin = 632.285 uV 14:25:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.739 uVs 14:25:36 Integrated Voltage Measurement... 14:25:45 Voltage Offset Correction: v_off_ini = 647.911 uV, v_off_fin = 642.234 uV 14:25:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.671 uVs 14:25:48 I2Y Average and RMS of Measurements VT = -510.918 +- 7.478 uVs I2Y = -47.005 +- 0.689 uTm^2 14:25:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:25:56 Integrated Voltage Measurement... 14:26:05 Voltage Offset Correction: v_off_ini = 651.447 uV, v_off_fin = 655.276 uV 14:26:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -70.493 uVs 14:26:05 Integrated Voltage Measurement... 14:26:14 Voltage Offset Correction: v_off_ini = 653.869 uV, v_off_fin = 661.582 uV 14:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.514 uVs 14:26:14 Integrated Voltage Measurement... 14:26:23 Voltage Offset Correction: v_off_ini = 649.813 uV, v_off_fin = 651.087 uV 14:26:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.936 uVs 14:26:23 Integrated Voltage Measurement... 14:26:32 Voltage Offset Correction: v_off_ini = 652.813 uV, v_off_fin = 652.687 uV 14:26:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.284 uVs 14:26:32 Integrated Voltage Measurement... 14:26:41 Voltage Offset Correction: v_off_ini = 659.633 uV, v_off_fin = 656.462 uV 14:26:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.002 uVs 14:26:41 Integrated Voltage Measurement... 14:26:50 Voltage Offset Correction: v_off_ini = 661.353 uV, v_off_fin = 648.169 uV 14:26:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.765 uVs 14:26:54 I1X Average and RMS of Measurements VT = -68.166 +- 5.948 uVs I1X = 13.634 +- 1.189 uTm 14:26:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:27:01 Integrated Voltage Measurement... 14:27:10 Voltage Offset Correction: v_off_ini = 656.775 uV, v_off_fin = 659.825 uV 14:27:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.044 uVs 14:27:10 Integrated Voltage Measurement... 14:27:19 Voltage Offset Correction: v_off_ini = 656.211 uV, v_off_fin = 655.137 uV 14:27:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.699 uVs 14:27:19 Integrated Voltage Measurement... 14:27:28 Voltage Offset Correction: v_off_ini = 637.703 uV, v_off_fin = 632.991 uV 14:27:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.736 uVs 14:27:28 Integrated Voltage Measurement... 14:27:37 Voltage Offset Correction: v_off_ini = 655.531 uV, v_off_fin = 659.225 uV 14:27:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.493 uVs 14:27:37 Integrated Voltage Measurement... 14:27:46 Voltage Offset Correction: v_off_ini = 645.534 uV, v_off_fin = 630.746 uV 14:27:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.009 uVs 14:27:46 Integrated Voltage Measurement... 14:27:55 Voltage Offset Correction: v_off_ini = 646.531 uV, v_off_fin = 657.045 uV 14:27:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.239 uVs 14:27:59 I1Y Average and RMS of Measurements VT = -196.870 +- 3.289 uVs I1Y = -39.370 +- 0.658 uTm 14:28:02 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:28:04 Integrated Voltage Measurement... 14:28:13 Voltage Offset Correction: v_off_ini = 649.984 uV, v_off_fin = 638.512 uV 14:28:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -42.559 uVs 14:28:13 Integrated Voltage Measurement... 14:28:22 Voltage Offset Correction: v_off_ini = 640.621 uV, v_off_fin = 642.191 uV 14:28:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.043 uVs 14:28:22 Integrated Voltage Measurement... 14:28:31 Voltage Offset Correction: v_off_ini = 652.559 uV, v_off_fin = 636.691 uV 14:28:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.014 uVs 14:28:31 Integrated Voltage Measurement... 14:28:40 Voltage Offset Correction: v_off_ini = 654.830 uV, v_off_fin = 666.022 uV 14:28:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.541 uVs 14:28:40 Integrated Voltage Measurement... 14:28:49 Voltage Offset Correction: v_off_ini = 651.117 uV, v_off_fin = 649.069 uV 14:28:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.133 uVs 14:28:49 Integrated Voltage Measurement... 14:28:58 Voltage Offset Correction: v_off_ini = 651.465 uV, v_off_fin = 661.376 uV 14:28:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.868 uVs 14:29:01 I2X Average and RMS of Measurements VT = -44.193 +- 5.734 uVs I2X = 4.066 +- 0.528 uTm^2 14:29:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:29:06 Integrated Voltage Measurement... 14:29:15 Voltage Offset Correction: v_off_ini = 669.436 uV, v_off_fin = 668.015 uV 14:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -529.110 uVs 14:29:15 Integrated Voltage Measurement... 14:29:24 Voltage Offset Correction: v_off_ini = 658.038 uV, v_off_fin = 658.484 uV 14:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 504.498 uVs 14:29:24 Integrated Voltage Measurement... 14:29:33 Voltage Offset Correction: v_off_ini = 657.390 uV, v_off_fin = 643.636 uV 14:29:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.915 uVs 14:29:33 Integrated Voltage Measurement... 14:29:42 Voltage Offset Correction: v_off_ini = 655.381 uV, v_off_fin = 650.707 uV 14:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.592 uVs 14:29:42 Integrated Voltage Measurement... 14:29:51 Voltage Offset Correction: v_off_ini = 646.720 uV, v_off_fin = 649.282 uV 14:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -528.858 uVs 14:29:51 Integrated Voltage Measurement... 14:30:00 Voltage Offset Correction: v_off_ini = 653.897 uV, v_off_fin = 643.729 uV 14:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.618 uVs 14:30:02 I2Y Average and RMS of Measurements VT = -514.432 +- 4.788 uVs I2Y = -47.328 +- 0.440 uTm^2 14:30:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:30:24 Integrated Voltage Measurement... 14:30:33 Voltage Offset Correction: v_off_ini = 658.060 uV, v_off_fin = 649.013 uV 14:30:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -112.269 uVs 14:30:33 Integrated Voltage Measurement... 14:30:42 Voltage Offset Correction: v_off_ini = 665.124 uV, v_off_fin = 662.534 uV 14:30:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.467 uVs 14:30:42 Integrated Voltage Measurement... 14:30:51 Voltage Offset Correction: v_off_ini = 657.042 uV, v_off_fin = 650.005 uV 14:30:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.940 uVs 14:30:51 Integrated Voltage Measurement... 14:31:00 Voltage Offset Correction: v_off_ini = 648.902 uV, v_off_fin = 658.008 uV 14:31:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.929 uVs 14:31:00 Integrated Voltage Measurement... 14:31:09 Voltage Offset Correction: v_off_ini = 650.518 uV, v_off_fin = 643.231 uV 14:31:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.975 uVs 14:31:09 Integrated Voltage Measurement... 14:31:18 Voltage Offset Correction: v_off_ini = 652.072 uV, v_off_fin = 661.214 uV 14:31:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.516 uVs 14:31:22 I1X Average and RMS of Measurements VT = -102.683 +- 6.614 uVs I1X = 20.538 +- 1.321 uTm 14:31:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:31:29 Integrated Voltage Measurement... 14:31:38 Voltage Offset Correction: v_off_ini = 656.660 uV, v_off_fin = 640.009 uV 14:31:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.846 uVs 14:31:38 Integrated Voltage Measurement... 14:31:47 Voltage Offset Correction: v_off_ini = 650.500 uV, v_off_fin = 658.083 uV 14:31:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.815 uVs 14:31:47 Integrated Voltage Measurement... 14:31:56 Voltage Offset Correction: v_off_ini = 650.236 uV, v_off_fin = 633.515 uV 14:31:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.195 uVs 14:31:56 Integrated Voltage Measurement... 14:32:05 Voltage Offset Correction: v_off_ini = 645.329 uV, v_off_fin = 665.696 uV 14:32:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.911 uVs 14:32:05 Integrated Voltage Measurement... 14:32:14 Voltage Offset Correction: v_off_ini = 651.440 uV, v_off_fin = 642.128 uV 14:32:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.816 uVs 14:32:14 Integrated Voltage Measurement... 14:32:23 Voltage Offset Correction: v_off_ini = 645.350 uV, v_off_fin = 648.530 uV 14:32:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.983 uVs 14:32:27 I1Y Average and RMS of Measurements VT = -209.761 +- 3.871 uVs I1Y = -41.952 +- 0.774 uTm 14:32:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:32:34 Integrated Voltage Measurement... 14:32:43 Voltage Offset Correction: v_off_ini = 640.379 uV, v_off_fin = 650.529 uV 14:32:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.781 uVs 14:32:44 Integrated Voltage Measurement... 14:32:52 Voltage Offset Correction: v_off_ini = 662.016 uV, v_off_fin = 656.935 uV 14:32:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.511 uVs 14:32:53 Integrated Voltage Measurement... 14:33:02 Voltage Offset Correction: v_off_ini = 650.041 uV, v_off_fin = 640.582 uV 14:33:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.698 uVs 14:33:02 Integrated Voltage Measurement... 14:33:11 Voltage Offset Correction: v_off_ini = 632.428 uV, v_off_fin = 646.210 uV 14:33:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.064 uVs 14:33:11 Integrated Voltage Measurement... 14:33:20 Voltage Offset Correction: v_off_ini = 625.103 uV, v_off_fin = 618.097 uV 14:33:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.517 uVs 14:33:20 Integrated Voltage Measurement... 14:33:29 Voltage Offset Correction: v_off_ini = 648.130 uV, v_off_fin = 652.719 uV 14:33:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.700 uVs 14:33:31 I2X Average and RMS of Measurements VT = -64.545 +- 6.009 uVs I2X = 5.938 +- 0.553 uTm^2 14:33:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:33:39 Integrated Voltage Measurement... 14:33:48 Voltage Offset Correction: v_off_ini = 654.745 uV, v_off_fin = 650.398 uV 14:33:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.268 uVs 14:33:48 Integrated Voltage Measurement... 14:33:57 Voltage Offset Correction: v_off_ini = 634.690 uV, v_off_fin = 649.724 uV 14:33:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.590 uVs 14:33:57 Integrated Voltage Measurement... 14:34:06 Voltage Offset Correction: v_off_ini = 634.756 uV, v_off_fin = 644.636 uV 14:34:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.880 uVs 14:34:06 Integrated Voltage Measurement... 14:34:15 Voltage Offset Correction: v_off_ini = 641.321 uV, v_off_fin = 643.807 uV 14:34:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.823 uVs 14:34:15 Integrated Voltage Measurement... 14:34:24 Voltage Offset Correction: v_off_ini = 621.302 uV, v_off_fin = 641.250 uV 14:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.748 uVs 14:34:24 Integrated Voltage Measurement... 14:34:33 Voltage Offset Correction: v_off_ini = 645.040 uV, v_off_fin = 645.991 uV 14:34:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 517.147 uVs 14:34:36 I2Y Average and RMS of Measurements VT = -509.076 +- 5.140 uVs I2Y = -46.835 +- 0.473 uTm^2 14:34:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:34:44 Integrated Voltage Measurement... 14:34:53 Voltage Offset Correction: v_off_ini = 645.781 uV, v_off_fin = 634.756 uV 14:34:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.552 uVs 14:34:53 Integrated Voltage Measurement... 14:35:02 Voltage Offset Correction: v_off_ini = 652.043 uV, v_off_fin = 642.348 uV 14:35:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.161 uVs 14:35:03 Integrated Voltage Measurement... 14:35:11 Voltage Offset Correction: v_off_ini = 640.301 uV, v_off_fin = 634.764 uV 14:35:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.050 uVs 14:35:12 Integrated Voltage Measurement... 14:35:20 Voltage Offset Correction: v_off_ini = 646.015 uV, v_off_fin = 644.108 uV 14:35:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.209 uVs 14:35:21 Integrated Voltage Measurement... 14:35:30 Voltage Offset Correction: v_off_ini = 645.426 uV, v_off_fin = 632.128 uV 14:35:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.395 uVs 14:35:30 Integrated Voltage Measurement... 14:35:39 Voltage Offset Correction: v_off_ini = 633.064 uV, v_off_fin = 646.074 uV 14:35:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.318 uVs 14:35:43 I1X Average and RMS of Measurements VT = -93.614 +- 8.631 uVs I1X = 18.723 +- 1.726 uTm 14:35:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:35:50 Integrated Voltage Measurement... 14:35:59 Voltage Offset Correction: v_off_ini = 622.591 uV, v_off_fin = 623.508 uV 14:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.071 uVs 14:35:59 Integrated Voltage Measurement... 14:36:08 Voltage Offset Correction: v_off_ini = 621.420 uV, v_off_fin = 631.682 uV 14:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.032 uVs 14:36:08 Integrated Voltage Measurement... 14:36:17 Voltage Offset Correction: v_off_ini = 610.904 uV, v_off_fin = 599.353 uV 14:36:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.896 uVs 14:36:17 Integrated Voltage Measurement... 14:36:26 Voltage Offset Correction: v_off_ini = 631.875 uV, v_off_fin = 634.991 uV 14:36:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.548 uVs 14:36:26 Integrated Voltage Measurement... 14:36:35 Voltage Offset Correction: v_off_ini = 649.071 uV, v_off_fin = 619.612 uV 14:36:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.771 uVs 14:36:35 Integrated Voltage Measurement... 14:36:44 Voltage Offset Correction: v_off_ini = 627.470 uV, v_off_fin = 635.861 uV 14:36:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.984 uVs 14:36:48 I1Y Average and RMS of Measurements VT = -212.884 +- 6.609 uVs I1Y = -42.577 +- 1.322 uTm 14:36:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:36:56 Integrated Voltage Measurement... 14:37:05 Voltage Offset Correction: v_off_ini = 638.723 uV, v_off_fin = 643.896 uV 14:37:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.163 uVs 14:37:05 Integrated Voltage Measurement... 14:37:14 Voltage Offset Correction: v_off_ini = 643.369 uV, v_off_fin = 666.609 uV 14:37:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.446 uVs 14:37:14 Integrated Voltage Measurement... 14:37:23 Voltage Offset Correction: v_off_ini = 649.949 uV, v_off_fin = 654.220 uV 14:37:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.034 uVs 14:37:23 Integrated Voltage Measurement... 14:37:32 Voltage Offset Correction: v_off_ini = 646.018 uV, v_off_fin = 656.337 uV 14:37:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.725 uVs 14:37:32 Integrated Voltage Measurement... 14:37:41 Voltage Offset Correction: v_off_ini = 642.104 uV, v_off_fin = 633.466 uV 14:37:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.030 uVs 14:37:41 Integrated Voltage Measurement... 14:37:50 Voltage Offset Correction: v_off_ini = 645.827 uV, v_off_fin = 648.217 uV 14:37:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.872 uVs 14:37:52 I2X Average and RMS of Measurements VT = -65.212 +- 6.043 uVs I2X = 6.000 +- 0.556 uTm^2 14:37:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:38:00 Integrated Voltage Measurement... 14:38:09 Voltage Offset Correction: v_off_ini = 658.534 uV, v_off_fin = 657.151 uV 14:38:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -519.056 uVs 14:38:09 Integrated Voltage Measurement... 14:38:18 Voltage Offset Correction: v_off_ini = 648.775 uV, v_off_fin = 658.662 uV 14:38:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.099 uVs 14:38:18 Integrated Voltage Measurement... 14:38:27 Voltage Offset Correction: v_off_ini = 651.269 uV, v_off_fin = 652.182 uV 14:38:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.452 uVs 14:38:27 Integrated Voltage Measurement... 14:38:36 Voltage Offset Correction: v_off_ini = 656.483 uV, v_off_fin = 650.629 uV 14:38:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.038 uVs 14:38:36 Integrated Voltage Measurement... 14:38:45 Voltage Offset Correction: v_off_ini = 659.937 uV, v_off_fin = 643.598 uV 14:38:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.625 uVs 14:38:45 Integrated Voltage Measurement... 14:38:54 Voltage Offset Correction: v_off_ini = 667.965 uV, v_off_fin = 660.537 uV 14:38:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.703 uVs 14:38:57 I2Y Average and RMS of Measurements VT = -508.829 +- 6.359 uVs I2Y = -46.812 +- 0.585 uTm^2 14:39:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:06 Integrated Voltage Measurement... 14:39:15 Voltage Offset Correction: v_off_ini = 648.879 uV, v_off_fin = 646.346 uV 14:39:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.053 uVs 14:39:15 Integrated Voltage Measurement... 14:39:24 Voltage Offset Correction: v_off_ini = 655.278 uV, v_off_fin = 658.281 uV 14:39:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.384 uVs 14:39:24 Integrated Voltage Measurement... 14:39:33 Voltage Offset Correction: v_off_ini = 658.510 uV, v_off_fin = 651.190 uV 14:39:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.633 uVs 14:39:33 Integrated Voltage Measurement... 14:39:42 Voltage Offset Correction: v_off_ini = 660.001 uV, v_off_fin = 661.383 uV 14:39:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 91.620 uVs 14:39:42 Integrated Voltage Measurement... 14:39:51 Voltage Offset Correction: v_off_ini = 649.654 uV, v_off_fin = 660.636 uV 14:39:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.037 uVs 14:39:51 Integrated Voltage Measurement... 14:40:00 Voltage Offset Correction: v_off_ini = 650.234 uV, v_off_fin = 655.624 uV 14:40:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.712 uVs 14:40:04 I1X Average and RMS of Measurements VT = -97.573 +- 2.416 uVs I1X = 19.515 +- 0.484 uTm 14:40:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:11 Integrated Voltage Measurement... 14:40:20 Voltage Offset Correction: v_off_ini = 656.348 uV, v_off_fin = 650.651 uV 14:40:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.731 uVs 14:40:20 Integrated Voltage Measurement... 14:40:29 Voltage Offset Correction: v_off_ini = 656.814 uV, v_off_fin = 668.511 uV 14:40:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.732 uVs 14:40:29 Integrated Voltage Measurement... 14:40:38 Voltage Offset Correction: v_off_ini = 644.717 uV, v_off_fin = 647.568 uV 14:40:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.609 uVs 14:40:38 Integrated Voltage Measurement... 14:40:47 Voltage Offset Correction: v_off_ini = 659.145 uV, v_off_fin = 674.046 uV 14:40:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.071 uVs 14:40:47 Integrated Voltage Measurement... 14:40:56 Voltage Offset Correction: v_off_ini = 662.258 uV, v_off_fin = 661.126 uV 14:40:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.883 uVs 14:40:56 Integrated Voltage Measurement... 14:41:05 Voltage Offset Correction: v_off_ini = 657.209 uV, v_off_fin = 668.112 uV 14:41:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.140 uVs 14:41:09 I1Y Average and RMS of Measurements VT = -202.694 +- 5.283 uVs I1Y = -40.539 +- 1.057 uTm 14:41:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:17 Integrated Voltage Measurement... 14:41:26 Voltage Offset Correction: v_off_ini = 670.321 uV, v_off_fin = 671.713 uV 14:41:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -69.264 uVs 14:41:26 Integrated Voltage Measurement... 14:41:35 Voltage Offset Correction: v_off_ini = 676.503 uV, v_off_fin = 690.751 uV 14:41:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.015 uVs 14:41:35 Integrated Voltage Measurement... 14:41:44 Voltage Offset Correction: v_off_ini = 678.073 uV, v_off_fin = 662.926 uV 14:41:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -73.459 uVs 14:41:44 Integrated Voltage Measurement... 14:41:53 Voltage Offset Correction: v_off_ini = 673.453 uV, v_off_fin = 678.778 uV 14:41:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.646 uVs 14:41:53 Integrated Voltage Measurement... 14:42:02 Voltage Offset Correction: v_off_ini = 676.295 uV, v_off_fin = 656.867 uV 14:42:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.537 uVs 14:42:02 Integrated Voltage Measurement... 14:42:11 Voltage Offset Correction: v_off_ini = 672.802 uV, v_off_fin = 674.479 uV 14:42:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.236 uVs 14:42:14 I2X Average and RMS of Measurements VT = -69.026 +- 0.713 uVs I2X = 6.351 +- 0.066 uTm^2 14:42:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:21 Integrated Voltage Measurement... 14:42:30 Voltage Offset Correction: v_off_ini = 661.816 uV, v_off_fin = 665.774 uV 14:42:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.830 uVs 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 676.155 uV, v_off_fin = 669.034 uV 14:42:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.345 uVs 14:42:39 Integrated Voltage Measurement... 14:42:48 Voltage Offset Correction: v_off_ini = 673.197 uV, v_off_fin = 672.996 uV 14:42:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -511.562 uVs 14:42:49 Integrated Voltage Measurement... 14:42:58 Voltage Offset Correction: v_off_ini = 653.080 uV, v_off_fin = 658.306 uV 14:42:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 502.701 uVs 14:42:58 Integrated Voltage Measurement... 14:43:07 Voltage Offset Correction: v_off_ini = 659.463 uV, v_off_fin = 672.912 uV 14:43:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.545 uVs 14:43:07 Integrated Voltage Measurement... 14:43:16 Voltage Offset Correction: v_off_ini = 658.859 uV, v_off_fin = 662.645 uV 14:43:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.517 uVs 14:43:18 I2Y Average and RMS of Measurements VT = -506.083 +- 3.326 uVs I2Y = -46.560 +- 0.306 uTm^2 14:43:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:43:27 Integrated Voltage Measurement... 14:43:36 Voltage Offset Correction: v_off_ini = 654.893 uV, v_off_fin = 658.531 uV 14:43:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.173 uVs 14:43:36 Integrated Voltage Measurement... 14:43:45 Voltage Offset Correction: v_off_ini = 651.308 uV, v_off_fin = 658.344 uV 14:43:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.596 uVs 14:43:45 Integrated Voltage Measurement... 14:43:54 Voltage Offset Correction: v_off_ini = 654.221 uV, v_off_fin = 651.412 uV 14:43:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.923 uVs 14:43:54 Integrated Voltage Measurement... 14:44:03 Voltage Offset Correction: v_off_ini = 649.061 uV, v_off_fin = 659.381 uV 14:44:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.880 uVs 14:44:03 Integrated Voltage Measurement... 14:44:12 Voltage Offset Correction: v_off_ini = 654.145 uV, v_off_fin = 647.216 uV 14:44:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.762 uVs 14:44:12 Integrated Voltage Measurement... 14:44:21 Voltage Offset Correction: v_off_ini = 658.694 uV, v_off_fin = 662.550 uV 14:44:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.255 uVs 14:44:25 I1X Average and RMS of Measurements VT = -87.598 +- 7.171 uVs I1X = 17.520 +- 1.434 uTm 14:44:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:44:32 Integrated Voltage Measurement... 14:44:41 Voltage Offset Correction: v_off_ini = 646.447 uV, v_off_fin = 643.465 uV 14:44:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -205.162 uVs 14:44:41 Integrated Voltage Measurement... 14:44:50 Voltage Offset Correction: v_off_ini = 646.274 uV, v_off_fin = 659.021 uV 14:44:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.539 uVs 14:44:50 Integrated Voltage Measurement... 14:44:59 Voltage Offset Correction: v_off_ini = 645.003 uV, v_off_fin = 634.613 uV 14:44:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.550 uVs 14:44:59 Integrated Voltage Measurement... 14:45:08 Voltage Offset Correction: v_off_ini = 656.015 uV, v_off_fin = 651.975 uV 14:45:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.670 uVs 14:45:08 Integrated Voltage Measurement... 14:45:17 Voltage Offset Correction: v_off_ini = 648.189 uV, v_off_fin = 647.883 uV 14:45:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.486 uVs 14:45:17 Integrated Voltage Measurement... 14:45:26 Voltage Offset Correction: v_off_ini = 642.582 uV, v_off_fin = 657.651 uV 14:45:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.918 uVs 14:45:31 I1Y Average and RMS of Measurements VT = -204.888 +- 4.248 uVs I1Y = -40.978 +- 0.850 uTm 14:45:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:45:38 Integrated Voltage Measurement... 14:45:47 Voltage Offset Correction: v_off_ini = 639.680 uV, v_off_fin = 640.670 uV 14:45:47 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -49.575 uVs 14:45:47 Integrated Voltage Measurement... 14:45:56 Voltage Offset Correction: v_off_ini = 641.889 uV, v_off_fin = 649.972 uV 14:45:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.430 uVs 14:45:56 Integrated Voltage Measurement... 14:46:05 Voltage Offset Correction: v_off_ini = 644.951 uV, v_off_fin = 643.774 uV 14:46:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.087 uVs 14:46:05 Integrated Voltage Measurement... 14:46:14 Voltage Offset Correction: v_off_ini = 648.176 uV, v_off_fin = 653.375 uV 14:46:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.582 uVs 14:46:14 Integrated Voltage Measurement... 14:46:23 Voltage Offset Correction: v_off_ini = 650.735 uV, v_off_fin = 637.392 uV 14:46:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.501 uVs 14:46:23 Integrated Voltage Measurement... 14:46:32 Voltage Offset Correction: v_off_ini = 644.378 uV, v_off_fin = 656.829 uV 14:46:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.221 uVs 14:46:35 I2X Average and RMS of Measurements VT = -69.733 +- 9.763 uVs I2X = 6.415 +- 0.898 uTm^2 14:46:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:46:43 Integrated Voltage Measurement... 14:46:52 Voltage Offset Correction: v_off_ini = 647.171 uV, v_off_fin = 652.927 uV 14:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.203 uVs 14:46:52 Integrated Voltage Measurement... 14:47:01 Voltage Offset Correction: v_off_ini = 658.568 uV, v_off_fin = 662.843 uV 14:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.869 uVs 14:47:01 Integrated Voltage Measurement... 14:47:10 Voltage Offset Correction: v_off_ini = 653.836 uV, v_off_fin = 661.290 uV 14:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.963 uVs 14:47:10 Integrated Voltage Measurement... 14:47:19 Voltage Offset Correction: v_off_ini = 665.502 uV, v_off_fin = 671.984 uV 14:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 495.830 uVs 14:47:19 Integrated Voltage Measurement... 14:47:28 Voltage Offset Correction: v_off_ini = 649.534 uV, v_off_fin = 660.685 uV 14:47:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.037 uVs 14:47:28 Integrated Voltage Measurement... 14:47:37 Voltage Offset Correction: v_off_ini = 658.626 uV, v_off_fin = 652.974 uV 14:47:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.834 uVs 14:47:39 I2Y Average and RMS of Measurements VT = -503.956 +- 4.613 uVs I2Y = -46.364 +- 0.424 uTm^2 14:47:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:47:48 Integrated Voltage Measurement... 14:47:57 Voltage Offset Correction: v_off_ini = 658.418 uV, v_off_fin = 643.860 uV 14:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -89.022 uVs 14:47:57 Integrated Voltage Measurement... 14:48:06 Voltage Offset Correction: v_off_ini = 671.292 uV, v_off_fin = 656.669 uV 14:48:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.970 uVs 14:48:06 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = 641.215 uV, v_off_fin = 652.950 uV 14:48:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -96.318 uVs 14:48:15 Integrated Voltage Measurement... 14:48:24 Voltage Offset Correction: v_off_ini = 633.027 uV, v_off_fin = 650.893 uV 14:48:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 104.302 uVs 14:48:24 Integrated Voltage Measurement... 14:48:33 Voltage Offset Correction: v_off_ini = 644.248 uV, v_off_fin = 646.101 uV 14:48:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.732 uVs 14:48:33 Integrated Voltage Measurement... 14:48:42 Voltage Offset Correction: v_off_ini = 640.397 uV, v_off_fin = 650.425 uV 14:48:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.563 uVs 14:48:47 I1X Average and RMS of Measurements VT = -96.818 +- 7.041 uVs I1X = 19.365 +- 1.409 uTm 14:48:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:48:54 Integrated Voltage Measurement... 14:49:02 Voltage Offset Correction: v_off_ini = 641.951 uV, v_off_fin = 634.812 uV 14:49:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.738 uVs 14:49:03 Integrated Voltage Measurement... 14:49:11 Voltage Offset Correction: v_off_ini = 639.370 uV, v_off_fin = 664.194 uV 14:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.381 uVs 14:49:12 Integrated Voltage Measurement... 14:49:21 Voltage Offset Correction: v_off_ini = 653.660 uV, v_off_fin = 642.683 uV 14:49:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.394 uVs 14:49:21 Integrated Voltage Measurement... 14:49:30 Voltage Offset Correction: v_off_ini = 655.665 uV, v_off_fin = 666.146 uV 14:49:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.235 uVs 14:49:30 Integrated Voltage Measurement... 14:49:39 Voltage Offset Correction: v_off_ini = 650.339 uV, v_off_fin = 652.596 uV 14:49:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.048 uVs 14:49:39 Integrated Voltage Measurement... 14:49:48 Voltage Offset Correction: v_off_ini = 649.509 uV, v_off_fin = 651.646 uV 14:49:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.849 uVs 14:49:52 I1Y Average and RMS of Measurements VT = -197.274 +- 2.861 uVs I1Y = -39.455 +- 0.572 uTm 14:49:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:50:00 Integrated Voltage Measurement... 14:50:09 Voltage Offset Correction: v_off_ini = 633.445 uV, v_off_fin = 647.093 uV 14:50:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.506 uVs 14:50:09 Integrated Voltage Measurement... 14:50:18 Voltage Offset Correction: v_off_ini = 675.315 uV, v_off_fin = 677.553 uV 14:50:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.272 uVs 14:50:18 Integrated Voltage Measurement... 14:50:27 Voltage Offset Correction: v_off_ini = 655.145 uV, v_off_fin = 662.503 uV 14:50:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.239 uVs 14:50:27 Integrated Voltage Measurement... 14:50:36 Voltage Offset Correction: v_off_ini = 676.645 uV, v_off_fin = 662.610 uV 14:50:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.731 uVs 14:50:36 Integrated Voltage Measurement... 14:50:45 Voltage Offset Correction: v_off_ini = 659.251 uV, v_off_fin = 643.706 uV 14:50:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.073 uVs 14:50:45 Integrated Voltage Measurement... 14:50:54 Voltage Offset Correction: v_off_ini = 650.802 uV, v_off_fin = 649.870 uV 14:50:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.498 uVs 14:50:56 I2X Average and RMS of Measurements VT = -69.553 +- 1.108 uVs I2X = 6.399 +- 0.102 uTm^2 14:51:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:51:04 Integrated Voltage Measurement... 14:51:13 Voltage Offset Correction: v_off_ini = 631.595 uV, v_off_fin = 637.274 uV 14:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.259 uVs 14:51:13 Integrated Voltage Measurement... 14:51:22 Voltage Offset Correction: v_off_ini = 664.720 uV, v_off_fin = 651.262 uV 14:51:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.072 uVs 14:51:22 Integrated Voltage Measurement... 14:51:31 Voltage Offset Correction: v_off_ini = 645.307 uV, v_off_fin = 637.598 uV 14:51:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -499.636 uVs 14:51:31 Integrated Voltage Measurement... 14:51:40 Voltage Offset Correction: v_off_ini = 643.558 uV, v_off_fin = 648.946 uV 14:51:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 504.350 uVs 14:51:40 Integrated Voltage Measurement... 14:51:49 Voltage Offset Correction: v_off_ini = 635.951 uV, v_off_fin = 653.128 uV 14:51:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.417 uVs 14:51:49 Integrated Voltage Measurement... 14:51:58 Voltage Offset Correction: v_off_ini = 646.921 uV, v_off_fin = 651.612 uV 14:51:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 517.918 uVs 14:52:01 I2Y Average and RMS of Measurements VT = -502.109 +- 6.941 uVs I2Y = -46.194 +- 0.639 uTm^2 14:52:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:52:13 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 668.581 uV, v_off_fin = 659.452 uV 14:52:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -72.206 uVs 14:52:22 Integrated Voltage Measurement... 14:52:31 Voltage Offset Correction: v_off_ini = 648.816 uV, v_off_fin = 656.941 uV 14:52:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.956 uVs 14:52:31 Integrated Voltage Measurement... 14:52:40 Voltage Offset Correction: v_off_ini = 668.460 uV, v_off_fin = 662.368 uV 14:52:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.756 uVs 14:52:40 Integrated Voltage Measurement... 14:52:49 Voltage Offset Correction: v_off_ini = 669.396 uV, v_off_fin = 655.932 uV 14:52:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.221 uVs 14:52:49 Integrated Voltage Measurement... 14:52:58 Voltage Offset Correction: v_off_ini = 646.464 uV, v_off_fin = 637.176 uV 14:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.727 uVs 14:52:58 Integrated Voltage Measurement... 14:53:07 Voltage Offset Correction: v_off_ini = 656.836 uV, v_off_fin = 643.028 uV 14:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.392 uVs 14:53:11 I1X Average and RMS of Measurements VT = -86.876 +- 3.871 uVs I1X = 17.375 +- 0.774 uTm 14:53:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:53:18 Integrated Voltage Measurement... 14:53:27 Voltage Offset Correction: v_off_ini = 656.919 uV, v_off_fin = 646.305 uV 14:53:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -213.319 uVs 14:53:27 Integrated Voltage Measurement... 14:53:36 Voltage Offset Correction: v_off_ini = 655.995 uV, v_off_fin = 674.437 uV 14:53:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.737 uVs 14:53:36 Integrated Voltage Measurement... 14:53:45 Voltage Offset Correction: v_off_ini = 651.213 uV, v_off_fin = 652.632 uV 14:53:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.910 uVs 14:53:45 Integrated Voltage Measurement... 14:53:54 Voltage Offset Correction: v_off_ini = 660.658 uV, v_off_fin = 653.784 uV 14:53:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.715 uVs 14:53:54 Integrated Voltage Measurement... 14:54:03 Voltage Offset Correction: v_off_ini = 635.659 uV, v_off_fin = 654.368 uV 14:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.577 uVs 14:54:03 Integrated Voltage Measurement... 14:54:12 Voltage Offset Correction: v_off_ini = 663.410 uV, v_off_fin = 662.518 uV 14:54:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.732 uVs 14:54:16 I1Y Average and RMS of Measurements VT = -199.165 +- 5.021 uVs I1Y = -39.834 +- 1.006 uTm 14:54:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:54:21 Integrated Voltage Measurement... 14:54:30 Voltage Offset Correction: v_off_ini = 662.361 uV, v_off_fin = 649.158 uV 14:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.082 uVs 14:54:30 Integrated Voltage Measurement... 14:54:39 Voltage Offset Correction: v_off_ini = 652.287 uV, v_off_fin = 661.972 uV 14:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.688 uVs 14:54:39 Integrated Voltage Measurement... 14:54:48 Voltage Offset Correction: v_off_ini = 653.333 uV, v_off_fin = 642.826 uV 14:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.071 uVs 14:54:48 Integrated Voltage Measurement... 14:54:57 Voltage Offset Correction: v_off_ini = 646.918 uV, v_off_fin = 665.290 uV 14:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.719 uVs 14:54:57 Integrated Voltage Measurement... 14:55:06 Voltage Offset Correction: v_off_ini = 643.629 uV, v_off_fin = 646.195 uV 14:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.737 uVs 14:55:06 Integrated Voltage Measurement... 14:55:15 Voltage Offset Correction: v_off_ini = 666.065 uV, v_off_fin = 651.594 uV 14:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.331 uVs 14:55:18 I2X Average and RMS of Measurements VT = -58.938 +- 7.426 uVs I2X = 5.422 +- 0.683 uTm^2 14:55:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:55:23 Integrated Voltage Measurement... 14:55:32 Voltage Offset Correction: v_off_ini = 643.281 uV, v_off_fin = 640.434 uV 14:55:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -487.137 uVs 14:55:32 Integrated Voltage Measurement... 14:55:41 Voltage Offset Correction: v_off_ini = 641.148 uV, v_off_fin = 655.929 uV 14:55:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.795 uVs 14:55:41 Integrated Voltage Measurement... 14:55:50 Voltage Offset Correction: v_off_ini = 654.505 uV, v_off_fin = 656.215 uV 14:55:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.528 uVs 14:55:50 Integrated Voltage Measurement... 14:55:59 Voltage Offset Correction: v_off_ini = 652.945 uV, v_off_fin = 654.329 uV 14:55:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.731 uVs 14:55:59 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = 650.906 uV, v_off_fin = 647.747 uV 14:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.520 uVs 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = 643.618 uV, v_off_fin = 645.847 uV 14:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.531 uVs 14:56:20 I2Y Average and RMS of Measurements VT = -496.374 +- 7.229 uVs I2Y = -45.666 +- 0.665 uTm^2 14:56:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:56:28 Integrated Voltage Measurement... 14:56:37 Voltage Offset Correction: v_off_ini = 630.716 uV, v_off_fin = 644.710 uV 14:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.648 uVs 14:56:37 Integrated Voltage Measurement... 14:56:46 Voltage Offset Correction: v_off_ini = 651.147 uV, v_off_fin = 656.518 uV 14:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.064 uVs 14:56:46 Integrated Voltage Measurement... 14:56:55 Voltage Offset Correction: v_off_ini = 657.860 uV, v_off_fin = 644.662 uV 14:56:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.988 uVs 14:56:55 Integrated Voltage Measurement... 14:57:04 Voltage Offset Correction: v_off_ini = 644.975 uV, v_off_fin = 647.108 uV 14:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.297 uVs 14:57:04 Integrated Voltage Measurement... 14:57:13 Voltage Offset Correction: v_off_ini = 652.764 uV, v_off_fin = 651.492 uV 14:57:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.839 uVs 14:57:13 Integrated Voltage Measurement... 14:57:22 Voltage Offset Correction: v_off_ini = 646.095 uV, v_off_fin = 655.086 uV 14:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.492 uVs 14:57:26 I1X Average and RMS of Measurements VT = -79.888 +- 10.160 uVs I1X = 15.978 +- 2.032 uTm 14:57:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:57:33 Integrated Voltage Measurement... 14:57:42 Voltage Offset Correction: v_off_ini = 657.708 uV, v_off_fin = 645.575 uV 14:57:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -189.026 uVs 14:57:42 Integrated Voltage Measurement... 14:57:51 Voltage Offset Correction: v_off_ini = 649.188 uV, v_off_fin = 660.432 uV 14:57:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.768 uVs 14:57:51 Integrated Voltage Measurement... 14:58:00 Voltage Offset Correction: v_off_ini = 672.102 uV, v_off_fin = 653.667 uV 14:58:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.077 uVs 14:58:00 Integrated Voltage Measurement... 14:58:09 Voltage Offset Correction: v_off_ini = 662.710 uV, v_off_fin = 663.738 uV 14:58:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.136 uVs 14:58:09 Integrated Voltage Measurement... 14:58:18 Voltage Offset Correction: v_off_ini = 650.298 uV, v_off_fin = 642.959 uV 14:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.822 uVs 14:58:18 Integrated Voltage Measurement... 14:58:27 Voltage Offset Correction: v_off_ini = 666.580 uV, v_off_fin = 670.438 uV 14:58:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.937 uVs 14:58:31 I1Y Average and RMS of Measurements VT = -204.294 +- 8.773 uVs I1Y = -40.860 +- 1.753 uTm 14:58:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:58:36 Integrated Voltage Measurement... 14:58:45 Voltage Offset Correction: v_off_ini = 657.501 uV, v_off_fin = 648.565 uV 14:58:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.406 uVs 14:58:45 Integrated Voltage Measurement... 14:58:54 Voltage Offset Correction: v_off_ini = 655.069 uV, v_off_fin = 655.069 uV 14:58:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.500 uVs 14:58:55 Integrated Voltage Measurement... 14:59:04 Voltage Offset Correction: v_off_ini = 653.554 uV, v_off_fin = 648.140 uV 14:59:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.499 uVs 14:59:04 Integrated Voltage Measurement... 14:59:13 Voltage Offset Correction: v_off_ini = 656.884 uV, v_off_fin = 657.194 uV 14:59:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.310 uVs 14:59:13 Integrated Voltage Measurement... 14:59:22 Voltage Offset Correction: v_off_ini = 660.535 uV, v_off_fin = 649.308 uV 14:59:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.576 uVs 14:59:22 Integrated Voltage Measurement... 14:59:31 Voltage Offset Correction: v_off_ini = 659.957 uV, v_off_fin = 663.998 uV 14:59:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.506 uVs 14:59:33 I2X Average and RMS of Measurements VT = -60.800 +- 4.344 uVs I2X = 5.594 +- 0.400 uTm^2 14:59:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:59:38 Integrated Voltage Measurement... 14:59:47 Voltage Offset Correction: v_off_ini = 656.506 uV, v_off_fin = 655.387 uV 14:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.711 uVs 14:59:47 Integrated Voltage Measurement... 14:59:56 Voltage Offset Correction: v_off_ini = 649.902 uV, v_off_fin = 652.031 uV 14:59:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.623 uVs 14:59:56 Integrated Voltage Measurement... 15:00:05 Voltage Offset Correction: v_off_ini = 652.434 uV, v_off_fin = 658.052 uV 15:00:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -527.224 uVs 15:00:05 Integrated Voltage Measurement... 15:00:14 Voltage Offset Correction: v_off_ini = 656.050 uV, v_off_fin = 658.159 uV 15:00:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 521.407 uVs 15:00:14 Integrated Voltage Measurement... 15:00:23 Voltage Offset Correction: v_off_ini = 666.606 uV, v_off_fin = 662.668 uV 15:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.972 uVs 15:00:23 Integrated Voltage Measurement... 15:00:32 Voltage Offset Correction: v_off_ini = 662.711 uV, v_off_fin = 661.634 uV 15:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.665 uVs 15:00:35 I2Y Average and RMS of Measurements VT = -511.600 +- 9.416 uVs I2Y = -47.067 +- 0.866 uTm^2 15:00:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:43 Integrated Voltage Measurement... 15:00:52 Voltage Offset Correction: v_off_ini = 656.867 uV, v_off_fin = 662.111 uV 15:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.124 uVs 15:00:52 Integrated Voltage Measurement... 15:01:01 Voltage Offset Correction: v_off_ini = 654.996 uV, v_off_fin = 652.616 uV 15:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.065 uVs 15:01:01 Integrated Voltage Measurement... 15:01:10 Voltage Offset Correction: v_off_ini = 653.858 uV, v_off_fin = 647.089 uV 15:01:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.285 uVs 15:01:10 Integrated Voltage Measurement... 15:01:19 Voltage Offset Correction: v_off_ini = 652.689 uV, v_off_fin = 656.017 uV 15:01:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.841 uVs 15:01:19 Integrated Voltage Measurement... 15:01:28 Voltage Offset Correction: v_off_ini = 657.053 uV, v_off_fin = 646.980 uV 15:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.942 uVs 15:01:28 Integrated Voltage Measurement... 15:01:37 Voltage Offset Correction: v_off_ini = 646.754 uV, v_off_fin = 647.245 uV 15:01:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.357 uVs 15:01:42 I1X Average and RMS of Measurements VT = -96.102 +- 2.019 uVs I1X = 19.220 +- 0.404 uTm 15:01:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:48 Integrated Voltage Measurement... 15:01:57 Voltage Offset Correction: v_off_ini = 660.324 uV, v_off_fin = 647.646 uV 15:01:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.626 uVs 15:01:57 Integrated Voltage Measurement... 15:02:06 Voltage Offset Correction: v_off_ini = 657.692 uV, v_off_fin = 670.708 uV 15:02:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.224 uVs 15:02:06 Integrated Voltage Measurement... 15:02:15 Voltage Offset Correction: v_off_ini = 664.580 uV, v_off_fin = 645.793 uV 15:02:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.255 uVs 15:02:15 Integrated Voltage Measurement... 15:02:24 Voltage Offset Correction: v_off_ini = 653.997 uV, v_off_fin = 662.615 uV 15:02:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.198 uVs 15:02:24 Integrated Voltage Measurement... 15:02:33 Voltage Offset Correction: v_off_ini = 645.314 uV, v_off_fin = 646.380 uV 15:02:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -215.300 uVs 15:02:33 Integrated Voltage Measurement... 15:02:42 Voltage Offset Correction: v_off_ini = 654.344 uV, v_off_fin = 662.063 uV 15:02:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.447 uVs 15:02:47 I1Y Average and RMS of Measurements VT = -200.008 +- 3.328 uVs I1Y = -40.002 +- 0.666 uTm 15:02:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:52 Integrated Voltage Measurement... 15:03:01 Voltage Offset Correction: v_off_ini = 655.338 uV, v_off_fin = 654.744 uV 15:03:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -73.461 uVs 15:03:01 Integrated Voltage Measurement... 15:03:10 Voltage Offset Correction: v_off_ini = 663.043 uV, v_off_fin = 667.234 uV 15:03:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.518 uVs 15:03:10 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 650.258 uV, v_off_fin = 658.193 uV 15:03:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.427 uVs 15:03:19 Integrated Voltage Measurement... 15:03:28 Voltage Offset Correction: v_off_ini = 664.470 uV, v_off_fin = 660.825 uV 15:03:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.776 uVs 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 658.969 uV, v_off_fin = 651.063 uV 15:03:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.874 uVs 15:03:37 Integrated Voltage Measurement... 15:03:46 Voltage Offset Correction: v_off_ini = 655.124 uV, v_off_fin = 667.741 uV 15:03:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.728 uVs 15:03:48 I2X Average and RMS of Measurements VT = -72.631 +- 2.747 uVs I2X = 6.682 +- 0.253 uTm^2 15:03:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:54 Integrated Voltage Measurement... 15:04:03 Voltage Offset Correction: v_off_ini = 678.259 uV, v_off_fin = 671.959 uV 15:04:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.090 uVs 15:04:03 Integrated Voltage Measurement... 15:04:12 Voltage Offset Correction: v_off_ini = 687.105 uV, v_off_fin = 679.047 uV 15:04:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.409 uVs 15:04:12 Integrated Voltage Measurement... 15:04:21 Voltage Offset Correction: v_off_ini = 664.901 uV, v_off_fin = 670.048 uV 15:04:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.945 uVs 15:04:21 Integrated Voltage Measurement... 15:04:30 Voltage Offset Correction: v_off_ini = 671.184 uV, v_off_fin = 669.600 uV 15:04:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 522.325 uVs 15:04:30 Integrated Voltage Measurement... 15:04:39 Voltage Offset Correction: v_off_ini = 679.848 uV, v_off_fin = 680.435 uV 15:04:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.842 uVs 15:04:39 Integrated Voltage Measurement... 15:04:48 Voltage Offset Correction: v_off_ini = 677.665 uV, v_off_fin = 678.507 uV 15:04:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 508.358 uVs 15:04:50 I2Y Average and RMS of Measurements VT = -509.662 +- 4.580 uVs I2Y = -46.889 +- 0.421 uTm^2 15:04:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:04:58 Integrated Voltage Measurement... 15:05:07 Voltage Offset Correction: v_off_ini = 678.429 uV, v_off_fin = 673.329 uV 15:05:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.284 uVs 15:05:08 Integrated Voltage Measurement... 15:05:16 Voltage Offset Correction: v_off_ini = 675.605 uV, v_off_fin = 674.329 uV 15:05:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.801 uVs 15:05:17 Integrated Voltage Measurement... 15:05:26 Voltage Offset Correction: v_off_ini = 682.244 uV, v_off_fin = 672.444 uV 15:05:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.865 uVs 15:05:26 Integrated Voltage Measurement... 15:05:35 Voltage Offset Correction: v_off_ini = 676.007 uV, v_off_fin = 673.307 uV 15:05:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.843 uVs 15:05:35 Integrated Voltage Measurement... 15:05:44 Voltage Offset Correction: v_off_ini = 680.514 uV, v_off_fin = 681.031 uV 15:05:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.979 uVs 15:05:44 Integrated Voltage Measurement... 15:05:53 Voltage Offset Correction: v_off_ini = 688.625 uV, v_off_fin = 691.396 uV 15:05:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.884 uVs 15:05:57 I1X Average and RMS of Measurements VT = -88.943 +- 5.979 uVs I1X = 17.789 +- 1.196 uTm 15:05:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:06:04 Integrated Voltage Measurement... 15:06:13 Voltage Offset Correction: v_off_ini = 682.169 uV, v_off_fin = 670.044 uV 15:06:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -192.824 uVs 15:06:13 Integrated Voltage Measurement... 15:06:22 Voltage Offset Correction: v_off_ini = 676.500 uV, v_off_fin = 696.381 uV 15:06:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.363 uVs 15:06:22 Integrated Voltage Measurement... 15:06:31 Voltage Offset Correction: v_off_ini = 679.580 uV, v_off_fin = 667.783 uV 15:06:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.438 uVs 15:06:31 Integrated Voltage Measurement... 15:06:40 Voltage Offset Correction: v_off_ini = 675.950 uV, v_off_fin = 688.152 uV 15:06:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.271 uVs 15:06:40 Integrated Voltage Measurement... 15:06:49 Voltage Offset Correction: v_off_ini = 685.397 uV, v_off_fin = 680.392 uV 15:06:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.694 uVs 15:06:49 Integrated Voltage Measurement... 15:06:58 Voltage Offset Correction: v_off_ini = 679.787 uV, v_off_fin = 691.344 uV 15:06:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.952 uVs 15:07:02 I1Y Average and RMS of Measurements VT = -202.924 +- 2.032 uVs I1Y = -40.585 +- 0.408 uTm 15:07:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:07:07 Integrated Voltage Measurement... 15:07:16 Voltage Offset Correction: v_off_ini = 681.279 uV, v_off_fin = 674.375 uV 15:07:16 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -53.564 uVs 15:07:16 Integrated Voltage Measurement... 15:07:25 Voltage Offset Correction: v_off_ini = 694.298 uV, v_off_fin = 686.816 uV 15:07:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.724 uVs 15:07:25 Integrated Voltage Measurement... 15:07:34 Voltage Offset Correction: v_off_ini = 683.664 uV, v_off_fin = 680.442 uV 15:07:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.633 uVs 15:07:34 Integrated Voltage Measurement... 15:07:43 Voltage Offset Correction: v_off_ini = 686.970 uV, v_off_fin = 698.846 uV 15:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.399 uVs 15:07:43 Integrated Voltage Measurement... 15:07:52 Voltage Offset Correction: v_off_ini = 694.633 uV, v_off_fin = 685.017 uV 15:07:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.485 uVs 15:07:52 Integrated Voltage Measurement... 15:08:01 Voltage Offset Correction: v_off_ini = 694.492 uV, v_off_fin = 697.195 uV 15:08:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.092 uVs 15:08:04 I2X Average and RMS of Measurements VT = -70.483 +- 7.240 uVs I2X = 6.485 +- 0.666 uTm^2 15:08:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:08:09 Integrated Voltage Measurement... 15:08:18 Voltage Offset Correction: v_off_ini = 690.291 uV, v_off_fin = 689.911 uV 15:08:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.278 uVs 15:08:18 Integrated Voltage Measurement... 15:08:27 Voltage Offset Correction: v_off_ini = 706.984 uV, v_off_fin = 695.854 uV 15:08:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.928 uVs 15:08:27 Integrated Voltage Measurement... 15:08:36 Voltage Offset Correction: v_off_ini = 691.950 uV, v_off_fin = 691.567 uV 15:08:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.477 uVs 15:08:36 Integrated Voltage Measurement... 15:08:45 Voltage Offset Correction: v_off_ini = 693.722 uV, v_off_fin = 687.154 uV 15:08:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.441 uVs 15:08:45 Integrated Voltage Measurement... 15:08:54 Voltage Offset Correction: v_off_ini = 698.431 uV, v_off_fin = 701.715 uV 15:08:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -522.652 uVs 15:08:54 Integrated Voltage Measurement... 15:09:03 Voltage Offset Correction: v_off_ini = 701.803 uV, v_off_fin = 701.334 uV 15:09:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 509.325 uVs 15:09:05 I2Y Average and RMS of Measurements VT = -510.517 +- 4.105 uVs I2Y = -46.968 +- 0.378 uTm^2 15:09:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:09:14 Integrated Voltage Measurement... 15:09:23 Voltage Offset Correction: v_off_ini = 694.245 uV, v_off_fin = 690.537 uV 15:09:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.489 uVs 15:09:23 Integrated Voltage Measurement... 15:09:32 Voltage Offset Correction: v_off_ini = 688.645 uV, v_off_fin = 700.517 uV 15:09:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.707 uVs 15:09:32 Integrated Voltage Measurement... 15:09:41 Voltage Offset Correction: v_off_ini = 693.880 uV, v_off_fin = 697.171 uV 15:09:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.095 uVs 15:09:41 Integrated Voltage Measurement... 15:09:50 Voltage Offset Correction: v_off_ini = 696.216 uV, v_off_fin = 695.341 uV 15:09:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.417 uVs 15:09:50 Integrated Voltage Measurement... 15:09:59 Voltage Offset Correction: v_off_ini = 696.145 uV, v_off_fin = 694.402 uV 15:09:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.362 uVs 15:09:59 Integrated Voltage Measurement... 15:10:08 Voltage Offset Correction: v_off_ini = 700.286 uV, v_off_fin = 695.248 uV 15:10:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 79.295 uVs 15:10:12 I1X Average and RMS of Measurements VT = -85.561 +- 4.786 uVs I1X = 17.114 +- 0.958 uTm 15:10:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:10:19 Integrated Voltage Measurement... 15:10:28 Voltage Offset Correction: v_off_ini = 694.808 uV, v_off_fin = 678.998 uV 15:10:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.233 uVs 15:10:28 Integrated Voltage Measurement... 15:10:37 Voltage Offset Correction: v_off_ini = 698.305 uV, v_off_fin = 716.061 uV 15:10:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.488 uVs 15:10:37 Integrated Voltage Measurement... 15:10:46 Voltage Offset Correction: v_off_ini = 693.596 uV, v_off_fin = 686.975 uV 15:10:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.628 uVs 15:10:46 Integrated Voltage Measurement... 15:10:55 Voltage Offset Correction: v_off_ini = 698.444 uV, v_off_fin = 706.286 uV 15:10:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.174 uVs 15:10:55 Integrated Voltage Measurement... 15:11:04 Voltage Offset Correction: v_off_ini = 683.511 uV, v_off_fin = 684.707 uV 15:11:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.873 uVs 15:11:04 Integrated Voltage Measurement... 15:11:13 Voltage Offset Correction: v_off_ini = 695.815 uV, v_off_fin = 707.816 uV 15:11:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.398 uVs 15:11:17 I1Y Average and RMS of Measurements VT = -195.799 +- 2.028 uVs I1Y = -39.157 +- 0.405 uTm 15:11:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:11:22 Integrated Voltage Measurement... 15:11:31 Voltage Offset Correction: v_off_ini = 699.215 uV, v_off_fin = 692.183 uV 15:11:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.609 uVs 15:11:31 Integrated Voltage Measurement... 15:11:40 Voltage Offset Correction: v_off_ini = 678.843 uV, v_off_fin = 687.099 uV 15:11:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.215 uVs 15:11:40 Integrated Voltage Measurement... 15:11:49 Voltage Offset Correction: v_off_ini = 672.043 uV, v_off_fin = 671.773 uV 15:11:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.000 uVs 15:11:50 Integrated Voltage Measurement... 15:11:59 Voltage Offset Correction: v_off_ini = 682.715 uV, v_off_fin = 703.372 uV 15:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.153 uVs 15:11:59 Integrated Voltage Measurement... 15:12:08 Voltage Offset Correction: v_off_ini = 680.542 uV, v_off_fin = 673.077 uV 15:12:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.693 uVs 15:12:08 Integrated Voltage Measurement... 15:12:17 Voltage Offset Correction: v_off_ini = 686.055 uV, v_off_fin = 678.365 uV 15:12:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.783 uVs 15:12:19 I2X Average and RMS of Measurements VT = -58.076 +- 8.100 uVs I2X = 5.343 +- 0.745 uTm^2 15:12:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:12:24 Integrated Voltage Measurement... 15:12:33 Voltage Offset Correction: v_off_ini = 677.324 uV, v_off_fin = 688.209 uV 15:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.879 uVs 15:12:33 Integrated Voltage Measurement... 15:12:42 Voltage Offset Correction: v_off_ini = 687.643 uV, v_off_fin = 675.965 uV 15:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 525.978 uVs 15:12:42 Integrated Voltage Measurement... 15:12:51 Voltage Offset Correction: v_off_ini = 676.260 uV, v_off_fin = 676.643 uV 15:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.972 uVs 15:12:51 Integrated Voltage Measurement... 15:13:00 Voltage Offset Correction: v_off_ini = 690.163 uV, v_off_fin = 684.673 uV 15:13:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 489.027 uVs 15:13:00 Integrated Voltage Measurement... 15:13:09 Voltage Offset Correction: v_off_ini = 682.134 uV, v_off_fin = 679.292 uV 15:13:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.310 uVs 15:13:09 Integrated Voltage Measurement... 15:13:18 Voltage Offset Correction: v_off_ini = 662.977 uV, v_off_fin = 674.017 uV 15:13:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 514.606 uVs 15:13:21 I2Y Average and RMS of Measurements VT = -511.462 +- 5.901 uVs I2Y = -47.055 +- 0.543 uTm^2 15:13:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:13:42 Integrated Voltage Measurement... 15:13:51 Voltage Offset Correction: v_off_ini = 703.331 uV, v_off_fin = 697.153 uV 15:13:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.352 uVs 15:13:51 Integrated Voltage Measurement... 15:14:00 Voltage Offset Correction: v_off_ini = 694.204 uV, v_off_fin = 679.022 uV 15:14:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.434 uVs 15:14:00 Integrated Voltage Measurement... 15:14:09 Voltage Offset Correction: v_off_ini = 684.956 uV, v_off_fin = 684.950 uV 15:14:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.672 uVs 15:14:09 Integrated Voltage Measurement... 15:14:18 Voltage Offset Correction: v_off_ini = 689.236 uV, v_off_fin = 684.577 uV 15:14:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.300 uVs 15:14:18 Integrated Voltage Measurement... 15:14:27 Voltage Offset Correction: v_off_ini = 668.302 uV, v_off_fin = 680.568 uV 15:14:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.899 uVs 15:14:27 Integrated Voltage Measurement... 15:14:36 Voltage Offset Correction: v_off_ini = 685.215 uV, v_off_fin = 684.266 uV 15:14:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.478 uVs 15:14:40 I1X Average and RMS of Measurements VT = -119.856 +- 3.563 uVs I1X = 23.971 +- 0.713 uTm 15:14:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:14:47 Integrated Voltage Measurement... 15:14:56 Voltage Offset Correction: v_off_ini = 667.922 uV, v_off_fin = 663.145 uV 15:14:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.453 uVs 15:14:56 Integrated Voltage Measurement... 15:15:05 Voltage Offset Correction: v_off_ini = 662.225 uV, v_off_fin = 670.319 uV 15:15:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.625 uVs 15:15:05 Integrated Voltage Measurement... 15:15:14 Voltage Offset Correction: v_off_ini = 678.869 uV, v_off_fin = 668.346 uV 15:15:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.181 uVs 15:15:14 Integrated Voltage Measurement... 15:15:23 Voltage Offset Correction: v_off_ini = 684.091 uV, v_off_fin = 685.972 uV 15:15:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.432 uVs 15:15:23 Integrated Voltage Measurement... 15:15:32 Voltage Offset Correction: v_off_ini = 680.170 uV, v_off_fin = 679.083 uV 15:15:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.740 uVs 15:15:32 Integrated Voltage Measurement... 15:15:41 Voltage Offset Correction: v_off_ini = 688.671 uV, v_off_fin = 707.889 uV 15:15:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.615 uVs 15:15:45 I1Y Average and RMS of Measurements VT = -209.674 +- 4.366 uVs I1Y = -41.935 +- 0.873 uTm 15:15:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 680.476 uV, v_off_fin = 674.364 uV 15:16:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -102.347 uVs 15:16:02 Integrated Voltage Measurement... 15:16:11 Voltage Offset Correction: v_off_ini = 678.649 uV, v_off_fin = 687.185 uV 15:16:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.561 uVs 15:16:11 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 685.622 uV, v_off_fin = 679.182 uV 15:16:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.546 uVs 15:16:20 Integrated Voltage Measurement... 15:16:29 Voltage Offset Correction: v_off_ini = 670.009 uV, v_off_fin = 688.124 uV 15:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.919 uVs 15:16:29 Integrated Voltage Measurement... 15:16:38 Voltage Offset Correction: v_off_ini = 692.321 uV, v_off_fin = 685.912 uV 15:16:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.917 uVs 15:16:38 Integrated Voltage Measurement... 15:16:47 Voltage Offset Correction: v_off_ini = 702.962 uV, v_off_fin = 700.270 uV 15:16:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.670 uVs 15:16:50 I2X Average and RMS of Measurements VT = -89.327 +- 6.833 uVs I2X = 8.218 +- 0.628 uTm^2 15:16:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:16:57 Integrated Voltage Measurement... 15:17:06 Voltage Offset Correction: v_off_ini = 686.599 uV, v_off_fin = 683.020 uV 15:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -516.489 uVs 15:17:06 Integrated Voltage Measurement... 15:17:15 Voltage Offset Correction: v_off_ini = 674.105 uV, v_off_fin = 688.325 uV 15:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 489.582 uVs 15:17:15 Integrated Voltage Measurement... 15:17:24 Voltage Offset Correction: v_off_ini = 688.952 uV, v_off_fin = 681.770 uV 15:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.872 uVs 15:17:25 Integrated Voltage Measurement... 15:17:33 Voltage Offset Correction: v_off_ini = 673.657 uV, v_off_fin = 689.883 uV 15:17:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.754 uVs 15:17:34 Integrated Voltage Measurement... 15:17:43 Voltage Offset Correction: v_off_ini = 689.942 uV, v_off_fin = 690.802 uV 15:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -518.973 uVs 15:17:43 Integrated Voltage Measurement... 15:17:52 Voltage Offset Correction: v_off_ini = 703.185 uV, v_off_fin = 691.349 uV 15:17:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.238 uVs 15:17:54 I2Y Average and RMS of Measurements VT = -503.818 +- 3.799 uVs I2Y = -46.351 +- 0.350 uTm^2 15:17:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:18:03 Integrated Voltage Measurement... 15:18:12 Voltage Offset Correction: v_off_ini = 690.783 uV, v_off_fin = 677.085 uV 15:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.989 uVs 15:18:12 Integrated Voltage Measurement... 15:18:21 Voltage Offset Correction: v_off_ini = 684.860 uV, v_off_fin = 687.083 uV 15:18:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.445 uVs 15:18:21 Integrated Voltage Measurement... 15:18:30 Voltage Offset Correction: v_off_ini = 674.812 uV, v_off_fin = 674.984 uV 15:18:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.498 uVs 15:18:30 Integrated Voltage Measurement... 15:18:39 Voltage Offset Correction: v_off_ini = 678.703 uV, v_off_fin = 668.669 uV 15:18:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.298 uVs 15:18:39 Integrated Voltage Measurement... 15:18:48 Voltage Offset Correction: v_off_ini = 678.051 uV, v_off_fin = 676.639 uV 15:18:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.347 uVs 15:18:48 Integrated Voltage Measurement... 15:18:57 Voltage Offset Correction: v_off_ini = 683.804 uV, v_off_fin = 687.813 uV 15:18:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.209 uVs 15:19:01 I1X Average and RMS of Measurements VT = -112.631 +- 9.064 uVs I1X = 22.527 +- 1.813 uTm 15:19:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:19:08 Integrated Voltage Measurement... 15:19:17 Voltage Offset Correction: v_off_ini = 676.911 uV, v_off_fin = 676.909 uV 15:19:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.021 uVs 15:19:17 Integrated Voltage Measurement... 15:19:26 Voltage Offset Correction: v_off_ini = 680.492 uV, v_off_fin = 691.481 uV 15:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.132 uVs 15:19:26 Integrated Voltage Measurement... 15:19:35 Voltage Offset Correction: v_off_ini = 672.143 uV, v_off_fin = 671.620 uV 15:19:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.878 uVs 15:19:35 Integrated Voltage Measurement... 15:19:44 Voltage Offset Correction: v_off_ini = 690.993 uV, v_off_fin = 695.152 uV 15:19:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.428 uVs 15:19:44 Integrated Voltage Measurement... 15:19:53 Voltage Offset Correction: v_off_ini = 688.415 uV, v_off_fin = 678.389 uV 15:19:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.170 uVs 15:19:53 Integrated Voltage Measurement... 15:20:02 Voltage Offset Correction: v_off_ini = 691.037 uV, v_off_fin = 696.088 uV 15:20:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.233 uVs 15:20:06 I1Y Average and RMS of Measurements VT = -214.477 +- 5.199 uVs I1Y = -42.895 +- 1.040 uTm 15:20:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:20:14 Integrated Voltage Measurement... 15:20:23 Voltage Offset Correction: v_off_ini = 678.694 uV, v_off_fin = 677.715 uV 15:20:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -115.116 uVs 15:20:23 Integrated Voltage Measurement... 15:20:32 Voltage Offset Correction: v_off_ini = 676.403 uV, v_off_fin = 685.264 uV 15:20:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.697 uVs 15:20:32 Integrated Voltage Measurement... 15:20:41 Voltage Offset Correction: v_off_ini = 671.390 uV, v_off_fin = 668.638 uV 15:20:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.129 uVs 15:20:41 Integrated Voltage Measurement... 15:20:50 Voltage Offset Correction: v_off_ini = 677.233 uV, v_off_fin = 693.454 uV 15:20:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.952 uVs 15:20:50 Integrated Voltage Measurement... 15:20:59 Voltage Offset Correction: v_off_ini = 680.102 uV, v_off_fin = 679.687 uV 15:20:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.262 uVs 15:20:59 Integrated Voltage Measurement... 15:21:08 Voltage Offset Correction: v_off_ini = 685.727 uV, v_off_fin = 684.883 uV 15:21:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.939 uVs 15:21:10 I2X Average and RMS of Measurements VT = -86.683 +- 8.846 uVs I2X = 7.975 +- 0.813 uTm^2 15:21:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:21:18 Integrated Voltage Measurement... 15:21:27 Voltage Offset Correction: v_off_ini = 667.537 uV, v_off_fin = 676.641 uV 15:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.484 uVs 15:21:27 Integrated Voltage Measurement... 15:21:36 Voltage Offset Correction: v_off_ini = 677.578 uV, v_off_fin = 686.826 uV 15:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.548 uVs 15:21:36 Integrated Voltage Measurement... 15:21:45 Voltage Offset Correction: v_off_ini = 687.497 uV, v_off_fin = 687.224 uV 15:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.675 uVs 15:21:45 Integrated Voltage Measurement... 15:21:54 Voltage Offset Correction: v_off_ini = 684.641 uV, v_off_fin = 683.942 uV 15:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.705 uVs 15:21:54 Integrated Voltage Measurement... 15:22:03 Voltage Offset Correction: v_off_ini = 669.016 uV, v_off_fin = 674.502 uV 15:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -508.260 uVs 15:22:03 Integrated Voltage Measurement... 15:22:12 Voltage Offset Correction: v_off_ini = 660.439 uV, v_off_fin = 681.859 uV 15:22:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 496.938 uVs 15:22:15 I2Y Average and RMS of Measurements VT = -503.268 +- 3.230 uVs I2Y = -46.301 +- 0.297 uTm^2 15:22:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:24 Integrated Voltage Measurement... 15:22:33 Voltage Offset Correction: v_off_ini = 692.849 uV, v_off_fin = 681.788 uV 15:22:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.997 uVs 15:22:33 Integrated Voltage Measurement... 15:22:42 Voltage Offset Correction: v_off_ini = 689.044 uV, v_off_fin = 691.730 uV 15:22:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.251 uVs 15:22:42 Integrated Voltage Measurement... 15:22:51 Voltage Offset Correction: v_off_ini = 680.419 uV, v_off_fin = 669.055 uV 15:22:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.693 uVs 15:22:51 Integrated Voltage Measurement... 15:23:00 Voltage Offset Correction: v_off_ini = 690.901 uV, v_off_fin = 685.715 uV 15:23:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.064 uVs 15:23:00 Integrated Voltage Measurement... 15:23:09 Voltage Offset Correction: v_off_ini = 681.716 uV, v_off_fin = 684.541 uV 15:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.926 uVs 15:23:09 Integrated Voltage Measurement... 15:23:18 Voltage Offset Correction: v_off_ini = 688.100 uV, v_off_fin = 688.405 uV 15:23:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.773 uVs 15:23:22 I1X Average and RMS of Measurements VT = -110.117 +- 4.623 uVs I1X = 22.025 +- 0.926 uTm 15:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:29 Integrated Voltage Measurement... 15:23:38 Voltage Offset Correction: v_off_ini = 696.357 uV, v_off_fin = 697.099 uV 15:23:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.250 uVs 15:23:38 Integrated Voltage Measurement... 15:23:47 Voltage Offset Correction: v_off_ini = 702.603 uV, v_off_fin = 706.051 uV 15:23:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.292 uVs 15:23:47 Integrated Voltage Measurement... 15:23:56 Voltage Offset Correction: v_off_ini = 693.949 uV, v_off_fin = 682.253 uV 15:23:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.006 uVs 15:23:56 Integrated Voltage Measurement... 15:24:05 Voltage Offset Correction: v_off_ini = 684.744 uV, v_off_fin = 699.208 uV 15:24:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.223 uVs 15:24:05 Integrated Voltage Measurement... 15:24:14 Voltage Offset Correction: v_off_ini = 702.777 uV, v_off_fin = 695.614 uV 15:24:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.257 uVs 15:24:14 Integrated Voltage Measurement... 15:24:23 Voltage Offset Correction: v_off_ini = 704.688 uV, v_off_fin = 711.692 uV 15:24:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.177 uVs 15:24:27 I1Y Average and RMS of Measurements VT = -211.534 +- 1.482 uVs I1Y = -42.307 +- 0.296 uTm 15:24:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:34 Integrated Voltage Measurement... 15:24:43 Voltage Offset Correction: v_off_ini = 687.991 uV, v_off_fin = 686.311 uV 15:24:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.770 uVs 15:24:44 Integrated Voltage Measurement... 15:24:53 Voltage Offset Correction: v_off_ini = 691.777 uV, v_off_fin = 699.673 uV 15:24:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.700 uVs 15:24:53 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 697.708 uV, v_off_fin = 687.411 uV 15:25:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.901 uVs 15:25:02 Integrated Voltage Measurement... 15:25:11 Voltage Offset Correction: v_off_ini = 690.073 uV, v_off_fin = 698.781 uV 15:25:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.758 uVs 15:25:11 Integrated Voltage Measurement... 15:25:20 Voltage Offset Correction: v_off_ini = 695.040 uV, v_off_fin = 698.429 uV 15:25:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.425 uVs 15:25:20 Integrated Voltage Measurement... 15:25:29 Voltage Offset Correction: v_off_ini = 691.875 uV, v_off_fin = 692.495 uV 15:25:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.776 uVs 15:25:31 I2X Average and RMS of Measurements VT = -91.222 +- 1.851 uVs I2X = 8.392 +- 0.170 uTm^2 15:25:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:39 Integrated Voltage Measurement... 15:25:48 Voltage Offset Correction: v_off_ini = 685.899 uV, v_off_fin = 677.012 uV 15:25:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -516.300 uVs 15:25:48 Integrated Voltage Measurement... 15:25:57 Voltage Offset Correction: v_off_ini = 669.429 uV, v_off_fin = 691.786 uV 15:25:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.731 uVs 15:25:57 Integrated Voltage Measurement... 15:26:06 Voltage Offset Correction: v_off_ini = 685.561 uV, v_off_fin = 695.078 uV 15:26:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -506.720 uVs 15:26:06 Integrated Voltage Measurement... 15:26:15 Voltage Offset Correction: v_off_ini = 680.081 uV, v_off_fin = 684.473 uV 15:26:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 511.958 uVs 15:26:15 Integrated Voltage Measurement... 15:26:24 Voltage Offset Correction: v_off_ini = 682.419 uV, v_off_fin = 691.883 uV 15:26:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.040 uVs 15:26:24 Integrated Voltage Measurement... 15:26:33 Voltage Offset Correction: v_off_ini = 692.544 uV, v_off_fin = 696.287 uV 15:26:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.261 uVs 15:26:35 I2Y Average and RMS of Measurements VT = -497.835 +- 10.149 uVs I2Y = -45.801 +- 0.934 uTm^2 15:26:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:26:44 Integrated Voltage Measurement... 15:26:53 Voltage Offset Correction: v_off_ini = 693.206 uV, v_off_fin = 698.958 uV 15:26:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -97.198 uVs 15:26:53 Integrated Voltage Measurement... 15:27:02 Voltage Offset Correction: v_off_ini = 708.660 uV, v_off_fin = 712.525 uV 15:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.171 uVs 15:27:02 Integrated Voltage Measurement... 15:27:11 Voltage Offset Correction: v_off_ini = 697.417 uV, v_off_fin = 697.521 uV 15:27:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.591 uVs 15:27:11 Integrated Voltage Measurement... 15:27:20 Voltage Offset Correction: v_off_ini = 685.297 uV, v_off_fin = 691.350 uV 15:27:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.676 uVs 15:27:20 Integrated Voltage Measurement... 15:27:29 Voltage Offset Correction: v_off_ini = 688.354 uV, v_off_fin = 695.889 uV 15:27:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.991 uVs 15:27:29 Integrated Voltage Measurement... 15:27:38 Voltage Offset Correction: v_off_ini = 698.691 uV, v_off_fin = 702.510 uV 15:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.386 uVs 15:27:42 I1X Average and RMS of Measurements VT = -113.835 +- 9.929 uVs I1X = 22.768 +- 1.985 uTm 15:27:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:27:49 Integrated Voltage Measurement... 15:27:58 Voltage Offset Correction: v_off_ini = 684.240 uV, v_off_fin = 685.677 uV 15:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.957 uVs 15:27:58 Integrated Voltage Measurement... 15:28:07 Voltage Offset Correction: v_off_ini = 694.027 uV, v_off_fin = 702.155 uV 15:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.446 uVs 15:28:07 Integrated Voltage Measurement... 15:28:16 Voltage Offset Correction: v_off_ini = 694.931 uV, v_off_fin = 694.303 uV 15:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.306 uVs 15:28:16 Integrated Voltage Measurement... 15:28:25 Voltage Offset Correction: v_off_ini = 705.056 uV, v_off_fin = 702.439 uV 15:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.971 uVs 15:28:25 Integrated Voltage Measurement... 15:28:34 Voltage Offset Correction: v_off_ini = 701.633 uV, v_off_fin = 687.772 uV 15:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.876 uVs 15:28:34 Integrated Voltage Measurement... 15:28:43 Voltage Offset Correction: v_off_ini = 692.378 uV, v_off_fin = 698.510 uV 15:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.013 uVs 15:28:47 I1Y Average and RMS of Measurements VT = -212.261 +- 7.174 uVs I1Y = -42.452 +- 1.435 uTm 15:28:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:28:55 Integrated Voltage Measurement... 15:29:04 Voltage Offset Correction: v_off_ini = 682.806 uV, v_off_fin = 678.961 uV 15:29:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.737 uVs 15:29:04 Integrated Voltage Measurement... 15:29:13 Voltage Offset Correction: v_off_ini = 693.316 uV, v_off_fin = 704.509 uV 15:29:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.028 uVs 15:29:13 Integrated Voltage Measurement... 15:29:22 Voltage Offset Correction: v_off_ini = 683.249 uV, v_off_fin = 685.782 uV 15:29:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.605 uVs 15:29:22 Integrated Voltage Measurement... 15:29:31 Voltage Offset Correction: v_off_ini = 689.861 uV, v_off_fin = 694.042 uV 15:29:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.830 uVs 15:29:31 Integrated Voltage Measurement... 15:29:40 Voltage Offset Correction: v_off_ini = 684.155 uV, v_off_fin = 673.697 uV 15:29:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.736 uVs 15:29:40 Integrated Voltage Measurement... 15:29:49 Voltage Offset Correction: v_off_ini = 685.744 uV, v_off_fin = 697.756 uV 15:29:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.602 uVs 15:29:52 I2X Average and RMS of Measurements VT = -94.256 +- 5.026 uVs I2X = 8.672 +- 0.462 uTm^2 15:29:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:29:59 Integrated Voltage Measurement... 15:30:08 Voltage Offset Correction: v_off_ini = 702.078 uV, v_off_fin = 697.299 uV 15:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.764 uVs 15:30:08 Integrated Voltage Measurement... 15:30:17 Voltage Offset Correction: v_off_ini = 697.764 uV, v_off_fin = 706.668 uV 15:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.136 uVs 15:30:17 Integrated Voltage Measurement... 15:30:26 Voltage Offset Correction: v_off_ini = 697.255 uV, v_off_fin = 700.570 uV 15:30:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -478.226 uVs 15:30:26 Integrated Voltage Measurement... 15:30:35 Voltage Offset Correction: v_off_ini = 679.321 uV, v_off_fin = 689.696 uV 15:30:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.740 uVs 15:30:35 Integrated Voltage Measurement... 15:30:44 Voltage Offset Correction: v_off_ini = 689.260 uV, v_off_fin = 690.671 uV 15:30:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.289 uVs 15:30:44 Integrated Voltage Measurement... 15:30:53 Voltage Offset Correction: v_off_ini = 699.222 uV, v_off_fin = 684.959 uV 15:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.406 uVs 15:30:56 I2Y Average and RMS of Measurements VT = -495.760 +- 7.164 uVs I2Y = -45.611 +- 0.658 uTm^2 15:31:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:31:05 Integrated Voltage Measurement... 15:31:14 Voltage Offset Correction: v_off_ini = 689.304 uV, v_off_fin = 677.376 uV 15:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.030 uVs 15:31:14 Integrated Voltage Measurement... 15:31:23 Voltage Offset Correction: v_off_ini = 692.619 uV, v_off_fin = 690.823 uV 15:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.433 uVs 15:31:23 Integrated Voltage Measurement... 15:31:32 Voltage Offset Correction: v_off_ini = 692.616 uV, v_off_fin = 681.828 uV 15:31:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.491 uVs 15:31:32 Integrated Voltage Measurement... 15:31:41 Voltage Offset Correction: v_off_ini = 692.643 uV, v_off_fin = 702.886 uV 15:31:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.447 uVs 15:31:41 Integrated Voltage Measurement... 15:31:50 Voltage Offset Correction: v_off_ini = 709.696 uV, v_off_fin = 701.546 uV 15:31:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.526 uVs 15:31:50 Integrated Voltage Measurement... 15:31:59 Voltage Offset Correction: v_off_ini = 686.705 uV, v_off_fin = 690.899 uV 15:31:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.431 uVs 15:32:03 I1X Average and RMS of Measurements VT = -114.393 +- 9.107 uVs I1X = 22.879 +- 1.821 uTm 15:32:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:32:10 Integrated Voltage Measurement... 15:32:19 Voltage Offset Correction: v_off_ini = 709.960 uV, v_off_fin = 679.861 uV 15:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.391 uVs 15:32:19 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = 683.731 uV, v_off_fin = 692.159 uV 15:32:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.726 uVs 15:32:28 Integrated Voltage Measurement... 15:32:37 Voltage Offset Correction: v_off_ini = 686.474 uV, v_off_fin = 690.866 uV 15:32:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.378 uVs 15:32:37 Integrated Voltage Measurement... 15:32:46 Voltage Offset Correction: v_off_ini = 693.890 uV, v_off_fin = 697.007 uV 15:32:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.271 uVs 15:32:46 Integrated Voltage Measurement... 15:32:55 Voltage Offset Correction: v_off_ini = 694.498 uV, v_off_fin = 685.997 uV 15:32:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.603 uVs 15:32:55 Integrated Voltage Measurement... 15:33:04 Voltage Offset Correction: v_off_ini = 696.557 uV, v_off_fin = 694.970 uV 15:33:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 187.133 uVs 15:33:08 I1Y Average and RMS of Measurements VT = -207.917 +- 3.560 uVs I1Y = -41.584 +- 0.711 uTm 15:33:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:33:16 Integrated Voltage Measurement... 15:33:25 Voltage Offset Correction: v_off_ini = 685.965 uV, v_off_fin = 689.715 uV 15:33:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.524 uVs 15:33:25 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = 700.158 uV, v_off_fin = 709.894 uV 15:33:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.242 uVs 15:33:34 Integrated Voltage Measurement... 15:33:43 Voltage Offset Correction: v_off_ini = 687.927 uV, v_off_fin = 699.852 uV 15:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.828 uVs 15:33:43 Integrated Voltage Measurement... 15:33:52 Voltage Offset Correction: v_off_ini = 695.473 uV, v_off_fin = 707.502 uV 15:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.970 uVs 15:33:52 Integrated Voltage Measurement... 15:34:01 Voltage Offset Correction: v_off_ini = 696.663 uV, v_off_fin = 699.064 uV 15:34:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.683 uVs 15:34:01 Integrated Voltage Measurement... 15:34:10 Voltage Offset Correction: v_off_ini = 710.015 uV, v_off_fin = 709.289 uV 15:34:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.734 uVs 15:34:13 I2X Average and RMS of Measurements VT = -92.830 +- 5.268 uVs I2X = 8.540 +- 0.485 uTm^2 15:34:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:34:20 Integrated Voltage Measurement... 15:34:29 Voltage Offset Correction: v_off_ini = 697.855 uV, v_off_fin = 698.407 uV 15:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.457 uVs 15:34:29 Integrated Voltage Measurement... 15:34:38 Voltage Offset Correction: v_off_ini = 697.578 uV, v_off_fin = 691.524 uV 15:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 496.183 uVs 15:34:38 Integrated Voltage Measurement... 15:34:47 Voltage Offset Correction: v_off_ini = 687.068 uV, v_off_fin = 700.257 uV 15:34:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.040 uVs 15:34:47 Integrated Voltage Measurement... 15:34:56 Voltage Offset Correction: v_off_ini = 696.624 uV, v_off_fin = 691.926 uV 15:34:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 485.279 uVs 15:34:57 Integrated Voltage Measurement... 15:35:06 Voltage Offset Correction: v_off_ini = 695.088 uV, v_off_fin = 693.758 uV 15:35:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -489.739 uVs 15:35:06 Integrated Voltage Measurement... 15:35:15 Voltage Offset Correction: v_off_ini = 701.400 uV, v_off_fin = 703.358 uV 15:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 487.648 uVs 15:35:17 I2Y Average and RMS of Measurements VT = -490.891 +- 3.132 uVs I2Y = -45.163 +- 0.288 uTm^2 15:35:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:35:29 Integrated Voltage Measurement... 15:35:38 Voltage Offset Correction: v_off_ini = 708.198 uV, v_off_fin = 703.661 uV 15:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -102.508 uVs 15:35:38 Integrated Voltage Measurement... 15:35:47 Voltage Offset Correction: v_off_ini = 701.694 uV, v_off_fin = 705.510 uV 15:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.024 uVs 15:35:47 Integrated Voltage Measurement... 15:35:56 Voltage Offset Correction: v_off_ini = 706.576 uV, v_off_fin = 691.379 uV 15:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.925 uVs 15:35:56 Integrated Voltage Measurement... 15:36:05 Voltage Offset Correction: v_off_ini = 701.725 uV, v_off_fin = 707.648 uV 15:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.569 uVs 15:36:05 Integrated Voltage Measurement... 15:36:14 Voltage Offset Correction: v_off_ini = 696.209 uV, v_off_fin = 695.041 uV 15:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.150 uVs 15:36:14 Integrated Voltage Measurement... 15:36:23 Voltage Offset Correction: v_off_ini = 701.857 uV, v_off_fin = 700.771 uV 15:36:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.880 uVs 15:36:27 I1X Average and RMS of Measurements VT = -99.843 +- 5.395 uVs I1X = 19.969 +- 1.080 uTm 15:36:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:36:34 Integrated Voltage Measurement... 15:36:43 Voltage Offset Correction: v_off_ini = 689.932 uV, v_off_fin = 685.900 uV 15:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.557 uVs 15:36:43 Integrated Voltage Measurement... 15:36:52 Voltage Offset Correction: v_off_ini = 689.381 uV, v_off_fin = 696.268 uV 15:36:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.650 uVs 15:36:52 Integrated Voltage Measurement... 15:37:01 Voltage Offset Correction: v_off_ini = 696.529 uV, v_off_fin = 682.703 uV 15:37:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.931 uVs 15:37:01 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 678.792 uV, v_off_fin = 687.336 uV 15:37:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.608 uVs 15:37:10 Integrated Voltage Measurement... 15:37:19 Voltage Offset Correction: v_off_ini = 673.149 uV, v_off_fin = 677.777 uV 15:37:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.749 uVs 15:37:19 Integrated Voltage Measurement... 15:37:28 Voltage Offset Correction: v_off_ini = 682.152 uV, v_off_fin = 694.124 uV 15:37:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.668 uVs 15:37:32 I1Y Average and RMS of Measurements VT = -210.194 +- 5.371 uVs I1Y = -42.039 +- 1.074 uTm 15:37:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:37:37 Integrated Voltage Measurement... 15:37:46 Voltage Offset Correction: v_off_ini = 660.345 uV, v_off_fin = 660.894 uV 15:37:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.778 uVs 15:37:46 Integrated Voltage Measurement... 15:37:55 Voltage Offset Correction: v_off_ini = 671.295 uV, v_off_fin = 681.247 uV 15:37:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.578 uVs 15:37:56 Integrated Voltage Measurement... 15:38:05 Voltage Offset Correction: v_off_ini = 691.812 uV, v_off_fin = 678.092 uV 15:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.969 uVs 15:38:05 Integrated Voltage Measurement... 15:38:14 Voltage Offset Correction: v_off_ini = 680.001 uV, v_off_fin = 679.606 uV 15:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.798 uVs 15:38:14 Integrated Voltage Measurement... 15:38:23 Voltage Offset Correction: v_off_ini = 658.388 uV, v_off_fin = 668.160 uV 15:38:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.469 uVs 15:38:23 Integrated Voltage Measurement... 15:38:32 Voltage Offset Correction: v_off_ini = 677.926 uV, v_off_fin = 680.498 uV 15:38:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.622 uVs 15:38:34 I2X Average and RMS of Measurements VT = -79.702 +- 7.529 uVs I2X = 7.333 +- 0.693 uTm^2 15:38:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:38:39 Integrated Voltage Measurement... 15:38:48 Voltage Offset Correction: v_off_ini = 686.455 uV, v_off_fin = 677.269 uV 15:38:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.329 uVs 15:38:48 Integrated Voltage Measurement... 15:38:57 Voltage Offset Correction: v_off_ini = 689.096 uV, v_off_fin = 687.962 uV 15:38:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 499.883 uVs 15:38:57 Integrated Voltage Measurement... 15:39:06 Voltage Offset Correction: v_off_ini = 688.552 uV, v_off_fin = 677.814 uV 15:39:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.868 uVs 15:39:06 Integrated Voltage Measurement... 15:39:15 Voltage Offset Correction: v_off_ini = 686.841 uV, v_off_fin = 689.489 uV 15:39:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.361 uVs 15:39:15 Integrated Voltage Measurement... 15:39:24 Voltage Offset Correction: v_off_ini = 677.357 uV, v_off_fin = 681.634 uV 15:39:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -484.778 uVs 15:39:24 Integrated Voltage Measurement... 15:39:33 Voltage Offset Correction: v_off_ini = 679.552 uV, v_off_fin = 679.736 uV 15:39:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.615 uVs 15:39:36 I2Y Average and RMS of Measurements VT = -491.306 +- 5.162 uVs I2Y = -45.201 +- 0.476 uTm^2 15:39:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:39:44 Integrated Voltage Measurement... 15:39:53 Voltage Offset Correction: v_off_ini = 692.367 uV, v_off_fin = 684.218 uV 15:39:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.446 uVs 15:39:53 Integrated Voltage Measurement... 15:40:02 Voltage Offset Correction: v_off_ini = 711.251 uV, v_off_fin = 688.875 uV 15:40:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.935 uVs 15:40:02 Integrated Voltage Measurement... 15:40:11 Voltage Offset Correction: v_off_ini = 697.205 uV, v_off_fin = 685.340 uV 15:40:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.509 uVs 15:40:11 Integrated Voltage Measurement... 15:40:20 Voltage Offset Correction: v_off_ini = 692.696 uV, v_off_fin = 695.545 uV 15:40:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.775 uVs 15:40:20 Integrated Voltage Measurement... 15:40:29 Voltage Offset Correction: v_off_ini = 688.381 uV, v_off_fin = 683.327 uV 15:40:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.646 uVs 15:40:29 Integrated Voltage Measurement... 15:40:38 Voltage Offset Correction: v_off_ini = 686.070 uV, v_off_fin = 693.874 uV 15:40:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.422 uVs 15:40:43 I1X Average and RMS of Measurements VT = -111.789 +- 12.911 uVs I1X = 22.359 +- 2.583 uTm 15:40:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:40:49 Integrated Voltage Measurement... 15:40:58 Voltage Offset Correction: v_off_ini = 678.435 uV, v_off_fin = 672.926 uV 15:40:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -194.858 uVs 15:40:58 Integrated Voltage Measurement... 15:41:07 Voltage Offset Correction: v_off_ini = 691.137 uV, v_off_fin = 701.244 uV 15:41:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.742 uVs 15:41:07 Integrated Voltage Measurement... 15:41:16 Voltage Offset Correction: v_off_ini = 689.451 uV, v_off_fin = 686.303 uV 15:41:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.372 uVs 15:41:16 Integrated Voltage Measurement... 15:41:25 Voltage Offset Correction: v_off_ini = 691.368 uV, v_off_fin = 709.362 uV 15:41:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.333 uVs 15:41:25 Integrated Voltage Measurement... 15:41:34 Voltage Offset Correction: v_off_ini = 699.840 uV, v_off_fin = 676.817 uV 15:41:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -198.953 uVs 15:41:34 Integrated Voltage Measurement... 15:41:43 Voltage Offset Correction: v_off_ini = 680.100 uV, v_off_fin = 702.210 uV 15:41:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.876 uVs 15:41:48 I1Y Average and RMS of Measurements VT = -205.356 +- 1.272 uVs I1Y = -41.073 +- 0.254 uTm 15:41:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:41:53 Integrated Voltage Measurement... 15:42:02 Voltage Offset Correction: v_off_ini = 686.637 uV, v_off_fin = 687.234 uV 15:42:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.676 uVs 15:42:02 Integrated Voltage Measurement... 15:42:11 Voltage Offset Correction: v_off_ini = 694.458 uV, v_off_fin = 698.327 uV 15:42:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.483 uVs 15:42:11 Integrated Voltage Measurement... 15:42:20 Voltage Offset Correction: v_off_ini = 705.825 uV, v_off_fin = 688.939 uV 15:42:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.849 uVs 15:42:20 Integrated Voltage Measurement... 15:42:29 Voltage Offset Correction: v_off_ini = 708.597 uV, v_off_fin = 707.059 uV 15:42:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.743 uVs 15:42:29 Integrated Voltage Measurement... 15:42:38 Voltage Offset Correction: v_off_ini = 697.776 uV, v_off_fin = 684.907 uV 15:42:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -67.397 uVs 15:42:38 Integrated Voltage Measurement... 15:42:47 Voltage Offset Correction: v_off_ini = 704.379 uV, v_off_fin = 699.163 uV 15:42:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.677 uVs 15:42:49 I2X Average and RMS of Measurements VT = -82.804 +- 7.806 uVs I2X = 7.618 +- 0.718 uTm^2 15:42:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:42:54 Integrated Voltage Measurement... 15:43:03 Voltage Offset Correction: v_off_ini = 691.315 uV, v_off_fin = 694.562 uV 15:43:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -495.211 uVs 15:43:04 Integrated Voltage Measurement... 15:43:12 Voltage Offset Correction: v_off_ini = 705.146 uV, v_off_fin = 706.889 uV 15:43:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 520.450 uVs 15:43:13 Integrated Voltage Measurement... 15:43:22 Voltage Offset Correction: v_off_ini = 709.636 uV, v_off_fin = 696.057 uV 15:43:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.853 uVs 15:43:22 Integrated Voltage Measurement... 15:43:31 Voltage Offset Correction: v_off_ini = 717.267 uV, v_off_fin = 710.529 uV 15:43:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.425 uVs 15:43:31 Integrated Voltage Measurement... 15:43:40 Voltage Offset Correction: v_off_ini = 714.994 uV, v_off_fin = 701.538 uV 15:43:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.601 uVs 15:43:40 Integrated Voltage Measurement... 15:43:49 Voltage Offset Correction: v_off_ini = 697.773 uV, v_off_fin = 705.160 uV 15:43:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 513.780 uVs 15:43:51 I2Y Average and RMS of Measurements VT = -499.887 +- 7.079 uVs I2Y = -45.990 +- 0.651 uTm^2 15:43:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:59 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = 703.334 uV, v_off_fin = 695.437 uV 15:44:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -113.936 uVs 15:44:08 Integrated Voltage Measurement... 15:44:17 Voltage Offset Correction: v_off_ini = 690.509 uV, v_off_fin = 694.334 uV 15:44:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.027 uVs 15:44:18 Integrated Voltage Measurement... 15:44:26 Voltage Offset Correction: v_off_ini = 709.544 uV, v_off_fin = 693.202 uV 15:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.997 uVs 15:44:27 Integrated Voltage Measurement... 15:44:36 Voltage Offset Correction: v_off_ini = 704.910 uV, v_off_fin = 695.202 uV 15:44:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.867 uVs 15:44:36 Integrated Voltage Measurement... 15:44:45 Voltage Offset Correction: v_off_ini = 691.875 uV, v_off_fin = 699.523 uV 15:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.322 uVs 15:44:45 Integrated Voltage Measurement... 15:44:54 Voltage Offset Correction: v_off_ini = 698.701 uV, v_off_fin = 695.957 uV 15:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.966 uVs 15:44:58 I1X Average and RMS of Measurements VT = -110.019 +- 4.600 uVs I1X = 22.005 +- 0.921 uTm 15:45:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:05 Integrated Voltage Measurement... 15:45:14 Voltage Offset Correction: v_off_ini = 696.241 uV, v_off_fin = 699.587 uV 15:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.195 uVs 15:45:14 Integrated Voltage Measurement... 15:45:23 Voltage Offset Correction: v_off_ini = 713.026 uV, v_off_fin = 711.816 uV 15:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.931 uVs 15:45:23 Integrated Voltage Measurement... 15:45:32 Voltage Offset Correction: v_off_ini = 712.299 uV, v_off_fin = 702.326 uV 15:45:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.558 uVs 15:45:32 Integrated Voltage Measurement... 15:45:41 Voltage Offset Correction: v_off_ini = 708.842 uV, v_off_fin = 711.783 uV 15:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.362 uVs 15:45:41 Integrated Voltage Measurement... 15:45:50 Voltage Offset Correction: v_off_ini = 708.222 uV, v_off_fin = 690.887 uV 15:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.326 uVs 15:45:50 Integrated Voltage Measurement... 15:45:59 Voltage Offset Correction: v_off_ini = 704.438 uV, v_off_fin = 709.944 uV 15:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.424 uVs 15:46:03 I1Y Average and RMS of Measurements VT = -209.299 +- 4.960 uVs I1Y = -41.860 +- 0.992 uTm 15:46:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:08 Integrated Voltage Measurement... 15:46:17 Voltage Offset Correction: v_off_ini = 682.160 uV, v_off_fin = 685.771 uV 15:46:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.496 uVs 15:46:17 Integrated Voltage Measurement... 15:46:26 Voltage Offset Correction: v_off_ini = 685.520 uV, v_off_fin = 706.010 uV 15:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.529 uVs 15:46:26 Integrated Voltage Measurement... 15:46:35 Voltage Offset Correction: v_off_ini = 699.023 uV, v_off_fin = 695.828 uV 15:46:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.423 uVs 15:46:35 Integrated Voltage Measurement... 15:46:44 Voltage Offset Correction: v_off_ini = 700.296 uV, v_off_fin = 723.543 uV 15:46:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.982 uVs 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = 727.934 uV, v_off_fin = 713.109 uV 15:46:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.508 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = 717.204 uV, v_off_fin = 723.753 uV 15:47:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.970 uVs 15:47:04 I2X Average and RMS of Measurements VT = -89.985 +- 1.345 uVs I2X = 8.279 +- 0.124 uTm^2 15:47:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:10 Integrated Voltage Measurement... 15:47:18 Voltage Offset Correction: v_off_ini = 716.565 uV, v_off_fin = 705.352 uV 15:47:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.408 uVs 15:47:19 Integrated Voltage Measurement... 15:47:28 Voltage Offset Correction: v_off_ini = 703.848 uV, v_off_fin = 718.116 uV 15:47:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.759 uVs 15:47:28 Integrated Voltage Measurement... 15:47:37 Voltage Offset Correction: v_off_ini = 713.099 uV, v_off_fin = 704.879 uV 15:47:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -494.456 uVs 15:47:37 Integrated Voltage Measurement... 15:47:46 Voltage Offset Correction: v_off_ini = 711.759 uV, v_off_fin = 712.541 uV 15:47:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.463 uVs 15:47:46 Integrated Voltage Measurement... 15:47:55 Voltage Offset Correction: v_off_ini = 702.368 uV, v_off_fin = 707.317 uV 15:47:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.492 uVs 15:47:55 Integrated Voltage Measurement... 15:48:04 Voltage Offset Correction: v_off_ini = 705.911 uV, v_off_fin = 708.141 uV 15:48:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.763 uVs 15:48:06 I2Y Average and RMS of Measurements VT = -495.557 +- 1.684 uVs I2Y = -45.591 +- 0.155 uTm^2 15:48:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:48:14 Integrated Voltage Measurement... 15:48:23 Voltage Offset Correction: v_off_ini = 720.319 uV, v_off_fin = 714.079 uV 15:48:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -141.747 uVs 15:48:24 Integrated Voltage Measurement... 15:48:32 Voltage Offset Correction: v_off_ini = 715.529 uV, v_off_fin = 720.478 uV 15:48:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.307 uVs 15:48:33 Integrated Voltage Measurement... 15:48:42 Voltage Offset Correction: v_off_ini = 712.684 uV, v_off_fin = 703.677 uV 15:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.466 uVs 15:48:42 Integrated Voltage Measurement... 15:48:51 Voltage Offset Correction: v_off_ini = 711.665 uV, v_off_fin = 714.065 uV 15:48:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.920 uVs 15:48:51 Integrated Voltage Measurement... 15:49:00 Voltage Offset Correction: v_off_ini = 693.880 uV, v_off_fin = 710.411 uV 15:49:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.538 uVs 15:49:00 Integrated Voltage Measurement... 15:49:09 Voltage Offset Correction: v_off_ini = 705.892 uV, v_off_fin = 694.417 uV 15:49:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.330 uVs 15:49:13 I1X Average and RMS of Measurements VT = -112.051 +- 7.761 uVs I1X = 22.411 +- 1.553 uTm 15:49:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:49:20 Integrated Voltage Measurement... 15:49:29 Voltage Offset Correction: v_off_ini = 683.790 uV, v_off_fin = 678.922 uV 15:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.419 uVs 15:49:29 Integrated Voltage Measurement... 15:49:38 Voltage Offset Correction: v_off_ini = 690.697 uV, v_off_fin = 694.235 uV 15:49:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.045 uVs 15:49:38 Integrated Voltage Measurement... 15:49:47 Voltage Offset Correction: v_off_ini = 686.859 uV, v_off_fin = 683.189 uV 15:49:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.881 uVs 15:49:47 Integrated Voltage Measurement... 15:49:56 Voltage Offset Correction: v_off_ini = 701.857 uV, v_off_fin = 710.661 uV 15:49:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.775 uVs 15:49:56 Integrated Voltage Measurement... 15:50:05 Voltage Offset Correction: v_off_ini = 695.898 uV, v_off_fin = 685.264 uV 15:50:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.633 uVs 15:50:05 Integrated Voltage Measurement... 15:50:14 Voltage Offset Correction: v_off_ini = 689.610 uV, v_off_fin = 699.642 uV 15:50:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.368 uVs 15:50:18 I1Y Average and RMS of Measurements VT = -202.187 +- 5.915 uVs I1Y = -40.433 +- 1.183 uTm 15:50:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:50:23 Integrated Voltage Measurement... 15:50:32 Voltage Offset Correction: v_off_ini = 679.829 uV, v_off_fin = 681.103 uV 15:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.906 uVs 15:50:32 Integrated Voltage Measurement... 15:50:41 Voltage Offset Correction: v_off_ini = 689.916 uV, v_off_fin = 692.502 uV 15:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.414 uVs 15:50:41 Integrated Voltage Measurement... 15:50:50 Voltage Offset Correction: v_off_ini = 693.200 uV, v_off_fin = 675.715 uV 15:50:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.354 uVs 15:50:50 Integrated Voltage Measurement... 15:50:59 Voltage Offset Correction: v_off_ini = 687.543 uV, v_off_fin = 686.080 uV 15:50:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.175 uVs 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = 690.317 uV, v_off_fin = 695.530 uV 15:51:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.294 uVs 15:51:09 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = 700.072 uV, v_off_fin = 705.920 uV 15:51:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.311 uVs 15:51:20 I2X Average and RMS of Measurements VT = -90.742 +- 6.319 uVs I2X = 8.348 +- 0.581 uTm^2 15:51:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:51:25 Integrated Voltage Measurement... 15:51:34 Voltage Offset Correction: v_off_ini = 689.023 uV, v_off_fin = 690.559 uV 15:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.906 uVs 15:51:34 Integrated Voltage Measurement... 15:51:43 Voltage Offset Correction: v_off_ini = 705.984 uV, v_off_fin = 708.396 uV 15:51:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.712 uVs 15:51:43 Integrated Voltage Measurement... 15:51:52 Voltage Offset Correction: v_off_ini = 708.698 uV, v_off_fin = 687.723 uV 15:51:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -490.138 uVs 15:51:52 Integrated Voltage Measurement... 15:52:01 Voltage Offset Correction: v_off_ini = 695.741 uV, v_off_fin = 700.644 uV 15:52:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 507.842 uVs 15:52:01 Integrated Voltage Measurement... 15:52:10 Voltage Offset Correction: v_off_ini = 714.884 uV, v_off_fin = 701.338 uV 15:52:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.900 uVs 15:52:10 Integrated Voltage Measurement... 15:52:19 Voltage Offset Correction: v_off_ini = 694.427 uV, v_off_fin = 705.201 uV 15:52:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.795 uVs 15:52:22 I2Y Average and RMS of Measurements VT = -497.716 +- 8.433 uVs I2Y = -45.790 +- 0.776 uTm^2 15:52:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:52:30 Integrated Voltage Measurement... 15:52:39 Voltage Offset Correction: v_off_ini = 705.730 uV, v_off_fin = 696.301 uV 15:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.122 uVs 15:52:39 Integrated Voltage Measurement... 15:52:48 Voltage Offset Correction: v_off_ini = 704.331 uV, v_off_fin = 699.005 uV 15:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.930 uVs 15:52:48 Integrated Voltage Measurement... 15:52:57 Voltage Offset Correction: v_off_ini = 696.716 uV, v_off_fin = 690.097 uV 15:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.541 uVs 15:52:57 Integrated Voltage Measurement... 15:53:06 Voltage Offset Correction: v_off_ini = 704.989 uV, v_off_fin = 694.159 uV 15:53:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.482 uVs 15:53:06 Integrated Voltage Measurement... 15:53:15 Voltage Offset Correction: v_off_ini = 714.226 uV, v_off_fin = 699.122 uV 15:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.930 uVs 15:53:15 Integrated Voltage Measurement... 15:53:24 Voltage Offset Correction: v_off_ini = 691.351 uV, v_off_fin = 691.514 uV 15:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.950 uVs 15:53:28 I1X Average and RMS of Measurements VT = -106.326 +- 9.988 uVs I1X = 21.266 +- 1.998 uTm 15:53:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:53:35 Integrated Voltage Measurement... 15:53:44 Voltage Offset Correction: v_off_ini = 685.555 uV, v_off_fin = 680.751 uV 15:53:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.901 uVs 15:53:44 Integrated Voltage Measurement... 15:53:53 Voltage Offset Correction: v_off_ini = 683.110 uV, v_off_fin = 689.530 uV 15:53:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.096 uVs 15:53:53 Integrated Voltage Measurement... 15:54:02 Voltage Offset Correction: v_off_ini = 681.835 uV, v_off_fin = 685.393 uV 15:54:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.751 uVs 15:54:02 Integrated Voltage Measurement... 15:54:11 Voltage Offset Correction: v_off_ini = 694.578 uV, v_off_fin = 695.167 uV 15:54:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.628 uVs 15:54:11 Integrated Voltage Measurement... 15:54:20 Voltage Offset Correction: v_off_ini = 688.855 uV, v_off_fin = 685.893 uV 15:54:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.373 uVs 15:54:20 Integrated Voltage Measurement... 15:54:29 Voltage Offset Correction: v_off_ini = 683.620 uV, v_off_fin = 676.487 uV 15:54:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.705 uVs 15:54:33 I1Y Average and RMS of Measurements VT = -208.742 +- 4.294 uVs I1Y = -41.746 +- 0.861 uTm 15:54:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:54:39 Integrated Voltage Measurement... 15:54:48 Voltage Offset Correction: v_off_ini = 668.216 uV, v_off_fin = 680.622 uV 15:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.854 uVs 15:54:48 Integrated Voltage Measurement... 15:54:57 Voltage Offset Correction: v_off_ini = 682.377 uV, v_off_fin = 679.808 uV 15:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.855 uVs 15:54:57 Integrated Voltage Measurement... 15:55:06 Voltage Offset Correction: v_off_ini = 677.442 uV, v_off_fin = 676.080 uV 15:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.148 uVs 15:55:06 Integrated Voltage Measurement... 15:55:15 Voltage Offset Correction: v_off_ini = 683.111 uV, v_off_fin = 688.823 uV 15:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.232 uVs 15:55:15 Integrated Voltage Measurement... 15:55:24 Voltage Offset Correction: v_off_ini = 683.944 uV, v_off_fin = 666.693 uV 15:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.715 uVs 15:55:24 Integrated Voltage Measurement... 15:55:33 Voltage Offset Correction: v_off_ini = 685.757 uV, v_off_fin = 690.869 uV 15:55:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.337 uVs 15:55:35 I2X Average and RMS of Measurements VT = -77.190 +- 6.594 uVs I2X = 7.101 +- 0.607 uTm^2 15:55:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:55:40 Integrated Voltage Measurement... 15:55:49 Voltage Offset Correction: v_off_ini = 668.837 uV, v_off_fin = 684.675 uV 15:55:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -507.540 uVs 15:55:49 Integrated Voltage Measurement... 15:55:58 Voltage Offset Correction: v_off_ini = 688.873 uV, v_off_fin = 681.102 uV 15:55:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.349 uVs 15:55:58 Integrated Voltage Measurement... 15:56:07 Voltage Offset Correction: v_off_ini = 686.825 uV, v_off_fin = 690.968 uV 15:56:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -530.891 uVs 15:56:07 Integrated Voltage Measurement... 15:56:16 Voltage Offset Correction: v_off_ini = 688.465 uV, v_off_fin = 686.443 uV 15:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.744 uVs 15:56:17 Integrated Voltage Measurement... 15:56:26 Voltage Offset Correction: v_off_ini = 689.018 uV, v_off_fin = 694.838 uV 15:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -510.770 uVs 15:56:26 Integrated Voltage Measurement... 15:56:35 Voltage Offset Correction: v_off_ini = 689.887 uV, v_off_fin = 691.800 uV 15:56:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.204 uVs 15:56:37 I2Y Average and RMS of Measurements VT = -501.750 +- 6.565 uVs I2Y = -46.161 +- 0.604 uTm^2 15:56:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:56:58 Integrated Voltage Measurement... 15:57:07 Voltage Offset Correction: v_off_ini = 692.675 uV, v_off_fin = 680.653 uV 15:57:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.378 uVs 15:57:07 Integrated Voltage Measurement... 15:57:16 Voltage Offset Correction: v_off_ini = 687.578 uV, v_off_fin = 694.295 uV 15:57:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.319 uVs 15:57:16 Integrated Voltage Measurement... 15:57:25 Voltage Offset Correction: v_off_ini = 688.990 uV, v_off_fin = 680.789 uV 15:57:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.506 uVs 15:57:25 Integrated Voltage Measurement... 15:57:34 Voltage Offset Correction: v_off_ini = 681.537 uV, v_off_fin = 683.121 uV 15:57:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 128.018 uVs 15:57:34 Integrated Voltage Measurement... 15:57:43 Voltage Offset Correction: v_off_ini = 675.066 uV, v_off_fin = 677.991 uV 15:57:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.645 uVs 15:57:43 Integrated Voltage Measurement... 15:57:52 Voltage Offset Correction: v_off_ini = 699.694 uV, v_off_fin = 682.271 uV 15:57:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.375 uVs 15:57:57 I1X Average and RMS of Measurements VT = -119.707 +- 3.069 uVs I1X = 23.942 +- 0.615 uTm 15:57:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:58:03 Integrated Voltage Measurement... 15:58:12 Voltage Offset Correction: v_off_ini = 687.801 uV, v_off_fin = 673.913 uV 15:58:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.814 uVs 15:58:12 Integrated Voltage Measurement... 15:58:21 Voltage Offset Correction: v_off_ini = 666.467 uV, v_off_fin = 688.284 uV 15:58:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.366 uVs 15:58:21 Integrated Voltage Measurement... 15:58:30 Voltage Offset Correction: v_off_ini = 681.890 uV, v_off_fin = 658.670 uV 15:58:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.844 uVs 15:58:30 Integrated Voltage Measurement... 15:58:39 Voltage Offset Correction: v_off_ini = 686.761 uV, v_off_fin = 686.575 uV 15:58:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.014 uVs 15:58:40 Integrated Voltage Measurement... 15:58:48 Voltage Offset Correction: v_off_ini = 668.771 uV, v_off_fin = 667.888 uV 15:58:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.954 uVs 15:58:49 Integrated Voltage Measurement... 15:58:57 Voltage Offset Correction: v_off_ini = 671.627 uV, v_off_fin = 678.002 uV 15:58:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.686 uVs 15:59:02 I1Y Average and RMS of Measurements VT = -214.613 +- 3.677 uVs I1Y = -42.923 +- 0.735 uTm 15:59:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:59:09 Integrated Voltage Measurement... 15:59:18 Voltage Offset Correction: v_off_ini = 666.038 uV, v_off_fin = 663.208 uV 15:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.895 uVs 15:59:19 Integrated Voltage Measurement... 15:59:27 Voltage Offset Correction: v_off_ini = 670.240 uV, v_off_fin = 674.637 uV 15:59:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.969 uVs 15:59:28 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 672.679 uV, v_off_fin = 664.168 uV 15:59:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.344 uVs 15:59:37 Integrated Voltage Measurement... 15:59:46 Voltage Offset Correction: v_off_ini = 679.590 uV, v_off_fin = 680.442 uV 15:59:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.776 uVs 15:59:46 Integrated Voltage Measurement... 15:59:55 Voltage Offset Correction: v_off_ini = 695.479 uV, v_off_fin = 691.673 uV 15:59:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.133 uVs 15:59:55 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = 686.052 uV, v_off_fin = 696.323 uV 16:00:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.233 uVs 16:00:06 I2X Average and RMS of Measurements VT = -107.725 +- 3.727 uVs I2X = 9.911 +- 0.343 uTm^2 16:00:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:00:14 Integrated Voltage Measurement... 16:00:23 Voltage Offset Correction: v_off_ini = 683.268 uV, v_off_fin = 678.626 uV 16:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -459.455 uVs 16:00:23 Integrated Voltage Measurement... 16:00:32 Voltage Offset Correction: v_off_ini = 682.078 uV, v_off_fin = 689.266 uV 16:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 485.880 uVs 16:00:32 Integrated Voltage Measurement... 16:00:41 Voltage Offset Correction: v_off_ini = 699.293 uV, v_off_fin = 688.823 uV 16:00:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.235 uVs 16:00:41 Integrated Voltage Measurement... 16:00:50 Voltage Offset Correction: v_off_ini = 693.437 uV, v_off_fin = 702.828 uV 16:00:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.957 uVs 16:00:50 Integrated Voltage Measurement... 16:00:59 Voltage Offset Correction: v_off_ini = 686.705 uV, v_off_fin = 686.170 uV 16:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.064 uVs 16:00:59 Integrated Voltage Measurement... 16:01:08 Voltage Offset Correction: v_off_ini = 691.163 uV, v_off_fin = 680.258 uV 16:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.294 uVs 16:01:10 I2Y Average and RMS of Measurements VT = -476.481 +- 3.036 uVs I2Y = -43.836 +- 0.279 uTm^2 16:01:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:01:19 Integrated Voltage Measurement... 16:01:28 Voltage Offset Correction: v_off_ini = 694.838 uV, v_off_fin = 685.428 uV 16:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.743 uVs 16:01:28 Integrated Voltage Measurement... 16:01:37 Voltage Offset Correction: v_off_ini = 686.186 uV, v_off_fin = 692.039 uV 16:01:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.594 uVs 16:01:37 Integrated Voltage Measurement... 16:01:46 Voltage Offset Correction: v_off_ini = 686.136 uV, v_off_fin = 685.190 uV 16:01:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.035 uVs 16:01:46 Integrated Voltage Measurement... 16:01:55 Voltage Offset Correction: v_off_ini = 689.537 uV, v_off_fin = 691.656 uV 16:01:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.240 uVs 16:01:55 Integrated Voltage Measurement... 16:02:04 Voltage Offset Correction: v_off_ini = 684.114 uV, v_off_fin = 681.816 uV 16:02:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.335 uVs 16:02:04 Integrated Voltage Measurement... 16:02:13 Voltage Offset Correction: v_off_ini = 687.267 uV, v_off_fin = 692.433 uV 16:02:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.085 uVs 16:02:17 I1X Average and RMS of Measurements VT = -124.839 +- 7.583 uVs I1X = 24.968 +- 1.517 uTm 16:02:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:02:24 Integrated Voltage Measurement... 16:02:33 Voltage Offset Correction: v_off_ini = 696.898 uV, v_off_fin = 686.455 uV 16:02:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.214 uVs 16:02:33 Integrated Voltage Measurement... 16:02:42 Voltage Offset Correction: v_off_ini = 697.023 uV, v_off_fin = 690.585 uV 16:02:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.703 uVs 16:02:42 Integrated Voltage Measurement... 16:02:51 Voltage Offset Correction: v_off_ini = 691.610 uV, v_off_fin = 679.409 uV 16:02:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.263 uVs 16:02:51 Integrated Voltage Measurement... 16:03:00 Voltage Offset Correction: v_off_ini = 697.312 uV, v_off_fin = 706.182 uV 16:03:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.568 uVs 16:03:00 Integrated Voltage Measurement... 16:03:09 Voltage Offset Correction: v_off_ini = 703.938 uV, v_off_fin = 693.205 uV 16:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.796 uVs 16:03:09 Integrated Voltage Measurement... 16:03:18 Voltage Offset Correction: v_off_ini = 717.938 uV, v_off_fin = 712.454 uV 16:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.579 uVs 16:03:22 I1Y Average and RMS of Measurements VT = -215.520 +- 1.354 uVs I1Y = -43.105 +- 0.271 uTm 16:03:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:03:30 Integrated Voltage Measurement... 16:03:39 Voltage Offset Correction: v_off_ini = 695.006 uV, v_off_fin = 677.819 uV 16:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.302 uVs 16:03:39 Integrated Voltage Measurement... 16:03:48 Voltage Offset Correction: v_off_ini = 689.698 uV, v_off_fin = 689.292 uV 16:03:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.613 uVs 16:03:48 Integrated Voltage Measurement... 16:03:57 Voltage Offset Correction: v_off_ini = 672.127 uV, v_off_fin = 660.416 uV 16:03:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.943 uVs 16:03:57 Integrated Voltage Measurement... 16:04:06 Voltage Offset Correction: v_off_ini = 679.147 uV, v_off_fin = 681.536 uV 16:04:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.918 uVs 16:04:06 Integrated Voltage Measurement... 16:04:15 Voltage Offset Correction: v_off_ini = 671.336 uV, v_off_fin = 665.663 uV 16:04:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.421 uVs 16:04:15 Integrated Voltage Measurement... 16:04:24 Voltage Offset Correction: v_off_ini = 663.910 uV, v_off_fin = 682.982 uV 16:04:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.867 uVs 16:04:27 I2X Average and RMS of Measurements VT = -103.177 +- 3.153 uVs I2X = 9.492 +- 0.290 uTm^2 16:04:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:04:34 Integrated Voltage Measurement... 16:04:43 Voltage Offset Correction: v_off_ini = 678.734 uV, v_off_fin = 672.610 uV 16:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.699 uVs 16:04:43 Integrated Voltage Measurement... 16:04:52 Voltage Offset Correction: v_off_ini = 665.238 uV, v_off_fin = 671.784 uV 16:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.016 uVs 16:04:52 Integrated Voltage Measurement... 16:05:01 Voltage Offset Correction: v_off_ini = 664.249 uV, v_off_fin = 665.691 uV 16:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.581 uVs 16:05:01 Integrated Voltage Measurement... 16:05:10 Voltage Offset Correction: v_off_ini = 659.312 uV, v_off_fin = 670.661 uV 16:05:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.317 uVs 16:05:10 Integrated Voltage Measurement... 16:05:19 Voltage Offset Correction: v_off_ini = 668.112 uV, v_off_fin = 679.289 uV 16:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.227 uVs 16:05:19 Integrated Voltage Measurement... 16:05:28 Voltage Offset Correction: v_off_ini = 687.903 uV, v_off_fin = 682.019 uV 16:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.353 uVs 16:05:31 I2Y Average and RMS of Measurements VT = -474.032 +- 9.014 uVs I2Y = -43.611 +- 0.829 uTm^2 16:05:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:40 Integrated Voltage Measurement... 16:05:49 Voltage Offset Correction: v_off_ini = 676.236 uV, v_off_fin = 669.005 uV 16:05:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.670 uVs 16:05:49 Integrated Voltage Measurement... 16:05:58 Voltage Offset Correction: v_off_ini = 666.371 uV, v_off_fin = 690.573 uV 16:05:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.090 uVs 16:05:58 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 683.044 uV, v_off_fin = 672.831 uV 16:06:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.456 uVs 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 688.341 uV, v_off_fin = 691.491 uV 16:06:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.488 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 679.827 uV, v_off_fin = 679.942 uV 16:06:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.054 uVs 16:06:25 Integrated Voltage Measurement... 16:06:34 Voltage Offset Correction: v_off_ini = 677.741 uV, v_off_fin = 689.589 uV 16:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.000 uVs 16:06:38 I1X Average and RMS of Measurements VT = -127.626 +- 2.684 uVs I1X = 25.526 +- 0.536 uTm 16:06:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:45 Integrated Voltage Measurement... 16:06:54 Voltage Offset Correction: v_off_ini = 685.431 uV, v_off_fin = 691.095 uV 16:06:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.821 uVs 16:06:54 Integrated Voltage Measurement... 16:07:03 Voltage Offset Correction: v_off_ini = 678.948 uV, v_off_fin = 695.295 uV 16:07:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.593 uVs 16:07:03 Integrated Voltage Measurement... 16:07:12 Voltage Offset Correction: v_off_ini = 683.076 uV, v_off_fin = 666.795 uV 16:07:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.449 uVs 16:07:12 Integrated Voltage Measurement... 16:07:21 Voltage Offset Correction: v_off_ini = 681.266 uV, v_off_fin = 680.672 uV 16:07:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.501 uVs 16:07:21 Integrated Voltage Measurement... 16:07:30 Voltage Offset Correction: v_off_ini = 669.812 uV, v_off_fin = 664.625 uV 16:07:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.910 uVs 16:07:30 Integrated Voltage Measurement... 16:07:39 Voltage Offset Correction: v_off_ini = 662.576 uV, v_off_fin = 676.087 uV 16:07:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.337 uVs 16:07:43 I1Y Average and RMS of Measurements VT = -211.102 +- 3.478 uVs I1Y = -42.220 +- 0.696 uTm 16:07:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:51 Integrated Voltage Measurement... 16:08:00 Voltage Offset Correction: v_off_ini = 654.640 uV, v_off_fin = 667.513 uV 16:08:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.302 uVs 16:08:00 Integrated Voltage Measurement... 16:08:09 Voltage Offset Correction: v_off_ini = 674.144 uV, v_off_fin = 676.737 uV 16:08:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.259 uVs 16:08:09 Integrated Voltage Measurement... 16:08:18 Voltage Offset Correction: v_off_ini = 664.852 uV, v_off_fin = 660.830 uV 16:08:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.903 uVs 16:08:18 Integrated Voltage Measurement... 16:08:27 Voltage Offset Correction: v_off_ini = 665.815 uV, v_off_fin = 683.459 uV 16:08:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.952 uVs 16:08:27 Integrated Voltage Measurement... 16:08:36 Voltage Offset Correction: v_off_ini = 680.156 uV, v_off_fin = 654.711 uV 16:08:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.622 uVs 16:08:36 Integrated Voltage Measurement... 16:08:45 Voltage Offset Correction: v_off_ini = 666.411 uV, v_off_fin = 673.802 uV 16:08:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.255 uVs 16:08:47 I2X Average and RMS of Measurements VT = -99.215 +- 3.928 uVs I2X = 9.128 +- 0.361 uTm^2 16:08:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:55 Integrated Voltage Measurement... 16:09:04 Voltage Offset Correction: v_off_ini = 661.787 uV, v_off_fin = 671.942 uV 16:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.842 uVs 16:09:04 Integrated Voltage Measurement... 16:09:13 Voltage Offset Correction: v_off_ini = 682.577 uV, v_off_fin = 674.303 uV 16:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 470.714 uVs 16:09:13 Integrated Voltage Measurement... 16:09:22 Voltage Offset Correction: v_off_ini = 685.986 uV, v_off_fin = 668.737 uV 16:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -490.933 uVs 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 673.658 uV, v_off_fin = 676.832 uV 16:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.399 uVs 16:09:31 Integrated Voltage Measurement... 16:09:40 Voltage Offset Correction: v_off_ini = 667.231 uV, v_off_fin = 659.883 uV 16:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.917 uVs 16:09:40 Integrated Voltage Measurement... 16:09:49 Voltage Offset Correction: v_off_ini = 672.126 uV, v_off_fin = 686.196 uV 16:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.981 uVs 16:09:51 I2Y Average and RMS of Measurements VT = -477.631 +- 8.711 uVs I2Y = -43.942 +- 0.801 uTm^2 16:09:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:10:00 Integrated Voltage Measurement... 16:10:09 Voltage Offset Correction: v_off_ini = 681.253 uV, v_off_fin = 692.408 uV 16:10:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -131.529 uVs 16:10:09 Integrated Voltage Measurement... 16:10:18 Voltage Offset Correction: v_off_ini = 685.455 uV, v_off_fin = 692.947 uV 16:10:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 121.744 uVs 16:10:18 Integrated Voltage Measurement... 16:10:27 Voltage Offset Correction: v_off_ini = 681.310 uV, v_off_fin = 682.137 uV 16:10:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.637 uVs 16:10:27 Integrated Voltage Measurement... 16:10:36 Voltage Offset Correction: v_off_ini = 681.811 uV, v_off_fin = 662.914 uV 16:10:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.789 uVs 16:10:36 Integrated Voltage Measurement... 16:10:45 Voltage Offset Correction: v_off_ini = 664.043 uV, v_off_fin = 672.430 uV 16:10:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.224 uVs 16:10:45 Integrated Voltage Measurement... 16:10:54 Voltage Offset Correction: v_off_ini = 676.100 uV, v_off_fin = 679.763 uV 16:10:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.911 uVs 16:10:59 I1X Average and RMS of Measurements VT = -122.639 +- 7.929 uVs I1X = 24.530 +- 1.585 uTm 16:11:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:11:05 Integrated Voltage Measurement... 16:11:14 Voltage Offset Correction: v_off_ini = 684.876 uV, v_off_fin = 673.429 uV 16:11:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.858 uVs 16:11:14 Integrated Voltage Measurement... 16:11:23 Voltage Offset Correction: v_off_ini = 670.758 uV, v_off_fin = 696.274 uV 16:11:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.366 uVs 16:11:23 Integrated Voltage Measurement... 16:11:32 Voltage Offset Correction: v_off_ini = 683.627 uV, v_off_fin = 681.372 uV 16:11:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.371 uVs 16:11:32 Integrated Voltage Measurement... 16:11:41 Voltage Offset Correction: v_off_ini = 696.993 uV, v_off_fin = 696.767 uV 16:11:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.146 uVs 16:11:41 Integrated Voltage Measurement... 16:11:50 Voltage Offset Correction: v_off_ini = 676.849 uV, v_off_fin = 674.013 uV 16:11:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.306 uVs 16:11:50 Integrated Voltage Measurement... 16:11:59 Voltage Offset Correction: v_off_ini = 686.693 uV, v_off_fin = 702.134 uV 16:11:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.339 uVs 16:12:04 I1Y Average and RMS of Measurements VT = -222.898 +- 2.893 uVs I1Y = -44.580 +- 0.579 uTm 16:12:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:12:11 Integrated Voltage Measurement... 16:12:20 Voltage Offset Correction: v_off_ini = 701.718 uV, v_off_fin = 695.941 uV 16:12:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.364 uVs 16:12:20 Integrated Voltage Measurement... 16:12:29 Voltage Offset Correction: v_off_ini = 699.044 uV, v_off_fin = 696.429 uV 16:12:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.533 uVs 16:12:29 Integrated Voltage Measurement... 16:12:38 Voltage Offset Correction: v_off_ini = 697.948 uV, v_off_fin = 685.335 uV 16:12:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.604 uVs 16:12:38 Integrated Voltage Measurement... 16:12:47 Voltage Offset Correction: v_off_ini = 686.272 uV, v_off_fin = 696.076 uV 16:12:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 109.690 uVs 16:12:47 Integrated Voltage Measurement... 16:12:56 Voltage Offset Correction: v_off_ini = 679.090 uV, v_off_fin = 674.722 uV 16:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.804 uVs 16:12:57 Integrated Voltage Measurement... 16:13:06 Voltage Offset Correction: v_off_ini = 692.321 uV, v_off_fin = 692.455 uV 16:13:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.050 uVs 16:13:08 I2X Average and RMS of Measurements VT = -107.841 +- 8.496 uVs I2X = 9.921 +- 0.781 uTm^2 16:13:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:13:16 Integrated Voltage Measurement... 16:13:25 Voltage Offset Correction: v_off_ini = 695.744 uV, v_off_fin = 691.860 uV 16:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.330 uVs 16:13:25 Integrated Voltage Measurement... 16:13:34 Voltage Offset Correction: v_off_ini = 694.684 uV, v_off_fin = 695.505 uV 16:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.968 uVs 16:13:34 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = 694.326 uV, v_off_fin = 703.505 uV 16:13:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -484.712 uVs 16:13:43 Integrated Voltage Measurement... 16:13:52 Voltage Offset Correction: v_off_ini = 689.453 uV, v_off_fin = 707.008 uV 16:13:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.698 uVs 16:13:52 Integrated Voltage Measurement... 16:14:01 Voltage Offset Correction: v_off_ini = 702.705 uV, v_off_fin = 709.395 uV 16:14:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.743 uVs 16:14:01 Integrated Voltage Measurement... 16:14:10 Voltage Offset Correction: v_off_ini = 682.804 uV, v_off_fin = 690.479 uV 16:14:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.397 uVs 16:14:12 I2Y Average and RMS of Measurements VT = -484.141 +- 7.183 uVs I2Y = -44.541 +- 0.661 uTm^2 16:14:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:14:21 Integrated Voltage Measurement... 16:14:30 Voltage Offset Correction: v_off_ini = 684.436 uV, v_off_fin = 691.195 uV 16:14:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -128.789 uVs 16:14:30 Integrated Voltage Measurement... 16:14:39 Voltage Offset Correction: v_off_ini = 692.519 uV, v_off_fin = 699.735 uV 16:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.290 uVs 16:14:39 Integrated Voltage Measurement... 16:14:48 Voltage Offset Correction: v_off_ini = 699.521 uV, v_off_fin = 701.106 uV 16:14:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.722 uVs 16:14:48 Integrated Voltage Measurement... 16:14:57 Voltage Offset Correction: v_off_ini = 703.883 uV, v_off_fin = 717.034 uV 16:14:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 122.884 uVs 16:14:57 Integrated Voltage Measurement... 16:15:06 Voltage Offset Correction: v_off_ini = 714.254 uV, v_off_fin = 715.086 uV 16:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.792 uVs 16:15:06 Integrated Voltage Measurement... 16:15:15 Voltage Offset Correction: v_off_ini = 716.880 uV, v_off_fin = 707.044 uV 16:15:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.189 uVs 16:15:20 I1X Average and RMS of Measurements VT = -125.278 +- 3.490 uVs I1X = 25.058 +- 0.699 uTm 16:15:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:15:26 Integrated Voltage Measurement... 16:15:35 Voltage Offset Correction: v_off_ini = 705.280 uV, v_off_fin = 702.110 uV 16:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.985 uVs 16:15:35 Integrated Voltage Measurement... 16:15:44 Voltage Offset Correction: v_off_ini = 719.186 uV, v_off_fin = 719.009 uV 16:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.811 uVs 16:15:44 Integrated Voltage Measurement... 16:15:53 Voltage Offset Correction: v_off_ini = 701.645 uV, v_off_fin = 675.261 uV 16:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.283 uVs 16:15:53 Integrated Voltage Measurement... 16:16:02 Voltage Offset Correction: v_off_ini = 694.238 uV, v_off_fin = 701.580 uV 16:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.895 uVs 16:16:02 Integrated Voltage Measurement... 16:16:11 Voltage Offset Correction: v_off_ini = 691.850 uV, v_off_fin = 682.512 uV 16:16:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.826 uVs 16:16:11 Integrated Voltage Measurement... 16:16:20 Voltage Offset Correction: v_off_ini = 678.969 uV, v_off_fin = 690.326 uV 16:16:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.454 uVs 16:16:25 I1Y Average and RMS of Measurements VT = -204.709 +- 5.027 uVs I1Y = -40.942 +- 1.005 uTm 16:16:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:16:32 Integrated Voltage Measurement... 16:16:41 Voltage Offset Correction: v_off_ini = 687.252 uV, v_off_fin = 681.248 uV 16:16:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.299 uVs 16:16:41 Integrated Voltage Measurement... 16:16:50 Voltage Offset Correction: v_off_ini = 684.679 uV, v_off_fin = 691.508 uV 16:16:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.185 uVs 16:16:51 Integrated Voltage Measurement... 16:17:00 Voltage Offset Correction: v_off_ini = 703.873 uV, v_off_fin = 692.489 uV 16:17:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.678 uVs 16:17:00 Integrated Voltage Measurement... 16:17:09 Voltage Offset Correction: v_off_ini = 703.872 uV, v_off_fin = 699.999 uV 16:17:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.727 uVs 16:17:09 Integrated Voltage Measurement... 16:17:18 Voltage Offset Correction: v_off_ini = 694.465 uV, v_off_fin = 686.578 uV 16:17:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.764 uVs 16:17:18 Integrated Voltage Measurement... 16:17:27 Voltage Offset Correction: v_off_ini = 679.087 uV, v_off_fin = 684.859 uV 16:17:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.660 uVs 16:17:29 I2X Average and RMS of Measurements VT = -103.885 +- 2.086 uVs I2X = 9.558 +- 0.192 uTm^2 16:17:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:17:37 Integrated Voltage Measurement... 16:17:46 Voltage Offset Correction: v_off_ini = 684.353 uV, v_off_fin = 688.436 uV 16:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.431 uVs 16:17:46 Integrated Voltage Measurement... 16:17:55 Voltage Offset Correction: v_off_ini = 693.918 uV, v_off_fin = 696.478 uV 16:17:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.929 uVs 16:17:55 Integrated Voltage Measurement... 16:18:04 Voltage Offset Correction: v_off_ini = 700.141 uV, v_off_fin = 688.617 uV 16:18:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.807 uVs 16:18:04 Integrated Voltage Measurement... 16:18:13 Voltage Offset Correction: v_off_ini = 710.640 uV, v_off_fin = 686.862 uV 16:18:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.731 uVs 16:18:13 Integrated Voltage Measurement... 16:18:22 Voltage Offset Correction: v_off_ini = 698.699 uV, v_off_fin = 700.139 uV 16:18:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.707 uVs 16:18:22 Integrated Voltage Measurement... 16:18:31 Voltage Offset Correction: v_off_ini = 713.011 uV, v_off_fin = 708.992 uV 16:18:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.408 uVs 16:18:33 I2Y Average and RMS of Measurements VT = -471.835 +- 11.660 uVs I2Y = -43.409 +- 1.073 uTm^2 16:18:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:18:45 Integrated Voltage Measurement... 16:18:54 Voltage Offset Correction: v_off_ini = 693.589 uV, v_off_fin = 687.700 uV 16:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.529 uVs 16:18:55 Integrated Voltage Measurement... 16:19:03 Voltage Offset Correction: v_off_ini = 710.955 uV, v_off_fin = 714.500 uV 16:19:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.702 uVs 16:19:04 Integrated Voltage Measurement... 16:19:12 Voltage Offset Correction: v_off_ini = 709.725 uV, v_off_fin = 688.284 uV 16:19:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.324 uVs 16:19:13 Integrated Voltage Measurement... 16:19:21 Voltage Offset Correction: v_off_ini = 692.355 uV, v_off_fin = 701.129 uV 16:19:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.388 uVs 16:19:22 Integrated Voltage Measurement... 16:19:31 Voltage Offset Correction: v_off_ini = 699.277 uV, v_off_fin = 702.063 uV 16:19:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.039 uVs 16:19:31 Integrated Voltage Measurement... 16:19:40 Voltage Offset Correction: v_off_ini = 703.433 uV, v_off_fin = 707.773 uV 16:19:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.820 uVs 16:19:44 I1X Average and RMS of Measurements VT = -116.634 +- 4.110 uVs I1X = 23.327 +- 0.822 uTm 16:19:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = 700.509 uV, v_off_fin = 693.597 uV 16:20:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.220 uVs 16:20:00 Integrated Voltage Measurement... 16:20:09 Voltage Offset Correction: v_off_ini = 697.715 uV, v_off_fin = 699.121 uV 16:20:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.957 uVs 16:20:09 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = 695.994 uV, v_off_fin = 691.249 uV 16:20:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.618 uVs 16:20:18 Integrated Voltage Measurement... 16:20:27 Voltage Offset Correction: v_off_ini = 700.321 uV, v_off_fin = 705.615 uV 16:20:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.176 uVs 16:20:27 Integrated Voltage Measurement... 16:20:36 Voltage Offset Correction: v_off_ini = 702.327 uV, v_off_fin = 690.736 uV 16:20:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.586 uVs 16:20:36 Integrated Voltage Measurement... 16:20:45 Voltage Offset Correction: v_off_ini = 701.780 uV, v_off_fin = 713.115 uV 16:20:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.681 uVs 16:20:49 I1Y Average and RMS of Measurements VT = -213.373 +- 4.329 uVs I1Y = -42.675 +- 0.866 uTm 16:20:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:20:54 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 697.315 uV, v_off_fin = 704.395 uV 16:21:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -106.759 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = 703.699 uV, v_off_fin = 718.308 uV 16:21:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.914 uVs 16:21:12 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = 720.480 uV, v_off_fin = 708.128 uV 16:21:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.300 uVs 16:21:21 Integrated Voltage Measurement... 16:21:30 Voltage Offset Correction: v_off_ini = 706.146 uV, v_off_fin = 711.947 uV 16:21:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.400 uVs 16:21:30 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = 714.857 uV, v_off_fin = 709.424 uV 16:21:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.966 uVs 16:21:39 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 724.059 uV, v_off_fin = 714.694 uV 16:21:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.499 uVs 16:21:51 I2X Average and RMS of Measurements VT = -109.306 +- 3.850 uVs I2X = 10.056 +- 0.354 uTm^2 16:21:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:21:56 Integrated Voltage Measurement... 16:22:05 Voltage Offset Correction: v_off_ini = 721.960 uV, v_off_fin = 716.568 uV 16:22:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.535 uVs 16:22:05 Integrated Voltage Measurement... 16:22:14 Voltage Offset Correction: v_off_ini = 710.792 uV, v_off_fin = 714.643 uV 16:22:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.586 uVs 16:22:14 Integrated Voltage Measurement... 16:22:23 Voltage Offset Correction: v_off_ini = 714.232 uV, v_off_fin = 721.093 uV 16:22:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -486.259 uVs 16:22:23 Integrated Voltage Measurement... 16:22:32 Voltage Offset Correction: v_off_ini = 719.209 uV, v_off_fin = 715.652 uV 16:22:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.888 uVs 16:22:32 Integrated Voltage Measurement... 16:22:41 Voltage Offset Correction: v_off_ini = 718.386 uV, v_off_fin = 720.834 uV 16:22:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -474.974 uVs 16:22:41 Integrated Voltage Measurement... 16:22:50 Voltage Offset Correction: v_off_ini = 720.909 uV, v_off_fin = 715.978 uV 16:22:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.716 uVs 16:22:52 I2Y Average and RMS of Measurements VT = -478.660 +- 3.682 uVs I2Y = -44.037 +- 0.339 uTm^2 16:22:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:23:01 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = 728.664 uV, v_off_fin = 729.637 uV 16:23:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.370 uVs 16:23:10 Integrated Voltage Measurement... 16:23:19 Voltage Offset Correction: v_off_ini = 717.575 uV, v_off_fin = 736.713 uV 16:23:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.004 uVs 16:23:19 Integrated Voltage Measurement... 16:23:28 Voltage Offset Correction: v_off_ini = 722.820 uV, v_off_fin = 728.142 uV 16:23:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.402 uVs 16:23:28 Integrated Voltage Measurement... 16:23:37 Voltage Offset Correction: v_off_ini = 747.020 uV, v_off_fin = 731.782 uV 16:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.723 uVs 16:23:37 Integrated Voltage Measurement... 16:23:46 Voltage Offset Correction: v_off_ini = 746.551 uV, v_off_fin = 737.520 uV 16:23:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.602 uVs 16:23:46 Integrated Voltage Measurement... 16:23:55 Voltage Offset Correction: v_off_ini = 733.937 uV, v_off_fin = 735.768 uV 16:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.571 uVs 16:23:59 I1X Average and RMS of Measurements VT = -115.779 +- 4.162 uVs I1X = 23.157 +- 0.833 uTm 16:24:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:24:06 Integrated Voltage Measurement... 16:24:15 Voltage Offset Correction: v_off_ini = 731.527 uV, v_off_fin = 708.450 uV 16:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.204 uVs 16:24:15 Integrated Voltage Measurement... 16:24:24 Voltage Offset Correction: v_off_ini = 713.964 uV, v_off_fin = 726.768 uV 16:24:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.075 uVs 16:24:24 Integrated Voltage Measurement... 16:24:33 Voltage Offset Correction: v_off_ini = 718.262 uV, v_off_fin = 706.490 uV 16:24:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.642 uVs 16:24:33 Integrated Voltage Measurement... 16:24:42 Voltage Offset Correction: v_off_ini = 709.180 uV, v_off_fin = 717.413 uV 16:24:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.700 uVs 16:24:42 Integrated Voltage Measurement... 16:24:51 Voltage Offset Correction: v_off_ini = 696.523 uV, v_off_fin = 689.108 uV 16:24:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.556 uVs 16:24:51 Integrated Voltage Measurement... 16:25:00 Voltage Offset Correction: v_off_ini = 706.921 uV, v_off_fin = 714.290 uV 16:25:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.796 uVs 16:25:04 I1Y Average and RMS of Measurements VT = -215.162 +- 0.819 uVs I1Y = -43.032 +- 0.164 uTm 16:25:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = 710.168 uV, v_off_fin = 695.629 uV 16:25:18 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.249 uVs 16:25:18 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = 691.453 uV, v_off_fin = 711.736 uV 16:25:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.698 uVs 16:25:27 Integrated Voltage Measurement... 16:25:36 Voltage Offset Correction: v_off_ini = 719.048 uV, v_off_fin = 714.868 uV 16:25:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.548 uVs 16:25:37 Integrated Voltage Measurement... 16:25:45 Voltage Offset Correction: v_off_ini = 728.089 uV, v_off_fin = 736.577 uV 16:25:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.029 uVs 16:25:46 Integrated Voltage Measurement... 16:25:55 Voltage Offset Correction: v_off_ini = 716.748 uV, v_off_fin = 709.161 uV 16:25:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.611 uVs 16:25:55 Integrated Voltage Measurement... 16:26:04 Voltage Offset Correction: v_off_ini = 715.755 uV, v_off_fin = 726.794 uV 16:26:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.851 uVs 16:26:06 I2X Average and RMS of Measurements VT = -108.498 +- 5.590 uVs I2X = 9.982 +- 0.514 uTm^2 16:26:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = 701.866 uV, v_off_fin = 695.450 uV 16:26:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.738 uVs 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = 699.805 uV, v_off_fin = 703.047 uV 16:26:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.107 uVs 16:26:29 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = 700.341 uV, v_off_fin = 706.886 uV 16:26:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -473.356 uVs 16:26:38 Integrated Voltage Measurement... 16:26:47 Voltage Offset Correction: v_off_ini = 723.360 uV, v_off_fin = 705.805 uV 16:26:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.790 uVs 16:26:47 Integrated Voltage Measurement... 16:26:56 Voltage Offset Correction: v_off_ini = 717.219 uV, v_off_fin = 705.323 uV 16:26:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.453 uVs 16:26:56 Integrated Voltage Measurement... 16:27:05 Voltage Offset Correction: v_off_ini = 711.970 uV, v_off_fin = 712.962 uV 16:27:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.216 uVs 16:27:08 I2Y Average and RMS of Measurements VT = -479.777 +- 0.552 uVs I2Y = -44.139 +- 0.051 uTm^2 16:27:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:16 Integrated Voltage Measurement... 16:27:25 Voltage Offset Correction: v_off_ini = 717.445 uV, v_off_fin = 707.955 uV 16:27:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -144.491 uVs 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = 709.187 uV, v_off_fin = 714.221 uV 16:27:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 134.292 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = 713.648 uV, v_off_fin = 709.475 uV 16:27:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.753 uVs 16:27:43 Integrated Voltage Measurement... 16:27:52 Voltage Offset Correction: v_off_ini = 722.984 uV, v_off_fin = 729.853 uV 16:27:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.877 uVs 16:27:52 Integrated Voltage Measurement... 16:28:01 Voltage Offset Correction: v_off_ini = 718.354 uV, v_off_fin = 720.959 uV 16:28:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.873 uVs 16:28:01 Integrated Voltage Measurement... 16:28:10 Voltage Offset Correction: v_off_ini = 714.566 uV, v_off_fin = 722.311 uV 16:28:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 129.247 uVs 16:28:15 I1X Average and RMS of Measurements VT = -132.922 +- 4.585 uVs I1X = 26.587 +- 0.919 uTm 16:28:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:21 Integrated Voltage Measurement... 16:28:30 Voltage Offset Correction: v_off_ini = 705.265 uV, v_off_fin = 702.134 uV 16:28:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.177 uVs 16:28:30 Integrated Voltage Measurement... 16:28:39 Voltage Offset Correction: v_off_ini = 706.817 uV, v_off_fin = 717.158 uV 16:28:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.859 uVs 16:28:39 Integrated Voltage Measurement... 16:28:48 Voltage Offset Correction: v_off_ini = 722.242 uV, v_off_fin = 690.749 uV 16:28:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.878 uVs 16:28:48 Integrated Voltage Measurement... 16:28:57 Voltage Offset Correction: v_off_ini = 713.237 uV, v_off_fin = 730.054 uV 16:28:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.660 uVs 16:28:57 Integrated Voltage Measurement... 16:29:06 Voltage Offset Correction: v_off_ini = 710.877 uV, v_off_fin = 703.633 uV 16:29:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.520 uVs 16:29:06 Integrated Voltage Measurement... 16:29:15 Voltage Offset Correction: v_off_ini = 714.942 uV, v_off_fin = 715.035 uV 16:29:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.525 uVs 16:29:19 I1Y Average and RMS of Measurements VT = -207.936 +- 1.329 uVs I1Y = -41.587 +- 0.266 uTm 16:29:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:25 Integrated Voltage Measurement... 16:29:34 Voltage Offset Correction: v_off_ini = 716.144 uV, v_off_fin = 712.274 uV 16:29:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.789 uVs 16:29:34 Integrated Voltage Measurement... 16:29:43 Voltage Offset Correction: v_off_ini = 718.128 uV, v_off_fin = 736.300 uV 16:29:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.021 uVs 16:29:43 Integrated Voltage Measurement... 16:29:52 Voltage Offset Correction: v_off_ini = 726.585 uV, v_off_fin = 714.941 uV 16:29:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.117 uVs 16:29:52 Integrated Voltage Measurement... 16:30:01 Voltage Offset Correction: v_off_ini = 707.823 uV, v_off_fin = 726.103 uV 16:30:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.119 uVs 16:30:01 Integrated Voltage Measurement... 16:30:10 Voltage Offset Correction: v_off_ini = 714.433 uV, v_off_fin = 717.469 uV 16:30:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.314 uVs 16:30:10 Integrated Voltage Measurement... 16:30:19 Voltage Offset Correction: v_off_ini = 723.058 uV, v_off_fin = 723.962 uV 16:30:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.173 uVs 16:30:21 I2X Average and RMS of Measurements VT = -103.422 +- 6.899 uVs I2X = 9.515 +- 0.635 uTm^2 16:30:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 725.354 uV, v_off_fin = 720.080 uV 16:30:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.978 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 740.267 uV, v_off_fin = 741.425 uV 16:30:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.477 uVs 16:30:45 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = 732.183 uV, v_off_fin = 731.089 uV 16:30:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.666 uVs 16:30:54 Integrated Voltage Measurement... 16:31:03 Voltage Offset Correction: v_off_ini = 735.096 uV, v_off_fin = 734.107 uV 16:31:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 474.894 uVs 16:31:03 Integrated Voltage Measurement... 16:31:12 Voltage Offset Correction: v_off_ini = 724.839 uV, v_off_fin = 716.511 uV 16:31:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.077 uVs 16:31:12 Integrated Voltage Measurement... 16:31:21 Voltage Offset Correction: v_off_ini = 723.307 uV, v_off_fin = 709.718 uV 16:31:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.460 uVs 16:31:23 I2Y Average and RMS of Measurements VT = -488.759 +- 7.947 uVs I2Y = -44.967 +- 0.730 uTm^2 16:31:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:31:31 Integrated Voltage Measurement... 16:31:40 Voltage Offset Correction: v_off_ini = 709.731 uV, v_off_fin = 703.597 uV 16:31:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -122.712 uVs 16:31:40 Integrated Voltage Measurement... 16:31:49 Voltage Offset Correction: v_off_ini = 699.663 uV, v_off_fin = 710.813 uV 16:31:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.158 uVs 16:31:49 Integrated Voltage Measurement... 16:31:58 Voltage Offset Correction: v_off_ini = 713.118 uV, v_off_fin = 709.903 uV 16:31:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.435 uVs 16:31:58 Integrated Voltage Measurement... 16:32:07 Voltage Offset Correction: v_off_ini = 721.102 uV, v_off_fin = 721.344 uV 16:32:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 105.081 uVs 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 713.559 uV, v_off_fin = 703.447 uV 16:32:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.830 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 718.022 uV, v_off_fin = 716.635 uV 16:32:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 115.719 uVs 16:32:30 I1X Average and RMS of Measurements VT = -115.489 +- 2.891 uVs I1X = 23.100 +- 0.578 uTm 16:32:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:32:37 Integrated Voltage Measurement... 16:32:46 Voltage Offset Correction: v_off_ini = 713.853 uV, v_off_fin = 700.963 uV 16:32:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.735 uVs 16:32:46 Integrated Voltage Measurement... 16:32:55 Voltage Offset Correction: v_off_ini = 704.136 uV, v_off_fin = 727.805 uV 16:32:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.422 uVs 16:32:55 Integrated Voltage Measurement... 16:33:04 Voltage Offset Correction: v_off_ini = 722.253 uV, v_off_fin = 698.412 uV 16:33:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.171 uVs 16:33:04 Integrated Voltage Measurement... 16:33:13 Voltage Offset Correction: v_off_ini = 716.861 uV, v_off_fin = 721.348 uV 16:33:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.934 uVs 16:33:13 Integrated Voltage Measurement... 16:33:22 Voltage Offset Correction: v_off_ini = 721.767 uV, v_off_fin = 712.556 uV 16:33:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.533 uVs 16:33:22 Integrated Voltage Measurement... 16:33:31 Voltage Offset Correction: v_off_ini = 710.012 uV, v_off_fin = 726.285 uV 16:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.643 uVs 16:33:35 I1Y Average and RMS of Measurements VT = -207.240 +- 4.884 uVs I1Y = -41.445 +- 0.975 uTm 16:33:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:33:40 Integrated Voltage Measurement... 16:33:49 Voltage Offset Correction: v_off_ini = 701.495 uV, v_off_fin = 688.606 uV 16:33:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.341 uVs 16:33:49 Integrated Voltage Measurement... 16:33:58 Voltage Offset Correction: v_off_ini = 714.635 uV, v_off_fin = 722.959 uV 16:33:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.037 uVs 16:33:58 Integrated Voltage Measurement... 16:34:07 Voltage Offset Correction: v_off_ini = 721.182 uV, v_off_fin = 713.075 uV 16:34:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.000 uVs 16:34:07 Integrated Voltage Measurement... 16:34:16 Voltage Offset Correction: v_off_ini = 720.729 uV, v_off_fin = 726.466 uV 16:34:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.699 uVs 16:34:16 Integrated Voltage Measurement... 16:34:25 Voltage Offset Correction: v_off_ini = 735.313 uV, v_off_fin = 711.159 uV 16:34:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.915 uVs 16:34:25 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = 721.841 uV, v_off_fin = 724.916 uV 16:34:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.890 uVs 16:34:37 I2X Average and RMS of Measurements VT = -106.480 +- 3.523 uVs I2X = 9.796 +- 0.324 uTm^2 16:34:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:34:42 Integrated Voltage Measurement... 16:34:51 Voltage Offset Correction: v_off_ini = 727.358 uV, v_off_fin = 710.613 uV 16:34:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -477.418 uVs 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 718.290 uV, v_off_fin = 727.526 uV 16:35:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.671 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 726.648 uV, v_off_fin = 719.107 uV 16:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -490.772 uVs 16:35:09 Integrated Voltage Measurement... 16:35:18 Voltage Offset Correction: v_off_ini = 712.721 uV, v_off_fin = 705.189 uV 16:35:18 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 500.186 uVs 16:35:18 Integrated Voltage Measurement... 16:35:27 Voltage Offset Correction: v_off_ini = 712.816 uV, v_off_fin = 713.048 uV 16:35:27 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -484.352 uVs 16:35:27 Integrated Voltage Measurement... 16:35:36 Voltage Offset Correction: v_off_ini = 730.756 uV, v_off_fin = 731.083 uV 16:35:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.531 uVs 16:35:38 I2Y Average and RMS of Measurements VT = -484.822 +- 8.045 uVs I2Y = -44.603 +- 0.738 uTm^2 16:35:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:35:47 Integrated Voltage Measurement... 16:35:56 Voltage Offset Correction: v_off_ini = 723.147 uV, v_off_fin = 736.522 uV 16:35:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -111.505 uVs 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 740.564 uV, v_off_fin = 757.440 uV 16:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.497 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 740.664 uV, v_off_fin = 733.310 uV 16:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.965 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 733.167 uV, v_off_fin = 743.281 uV 16:36:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.031 uVs 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 751.509 uV, v_off_fin = 737.106 uV 16:36:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.907 uVs 16:36:32 Integrated Voltage Measurement... 16:36:41 Voltage Offset Correction: v_off_ini = 750.511 uV, v_off_fin = 735.747 uV 16:36:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.539 uVs 16:36:45 I1X Average and RMS of Measurements VT = -114.408 +- 11.615 uVs I1X = 22.883 +- 2.323 uTm 16:36:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:36:52 Integrated Voltage Measurement... 16:37:01 Voltage Offset Correction: v_off_ini = 725.548 uV, v_off_fin = 716.813 uV 16:37:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.074 uVs 16:37:01 Integrated Voltage Measurement... 16:37:10 Voltage Offset Correction: v_off_ini = 723.098 uV, v_off_fin = 753.899 uV 16:37:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.177 uVs 16:37:10 Integrated Voltage Measurement... 16:37:19 Voltage Offset Correction: v_off_ini = 736.303 uV, v_off_fin = 732.222 uV 16:37:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -208.741 uVs 16:37:19 Integrated Voltage Measurement... 16:37:28 Voltage Offset Correction: v_off_ini = 722.355 uV, v_off_fin = 739.716 uV 16:37:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.270 uVs 16:37:28 Integrated Voltage Measurement... 16:37:37 Voltage Offset Correction: v_off_ini = 735.569 uV, v_off_fin = 721.410 uV 16:37:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -210.526 uVs 16:37:37 Integrated Voltage Measurement... 16:37:46 Voltage Offset Correction: v_off_ini = 743.051 uV, v_off_fin = 751.280 uV 16:37:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.893 uVs 16:37:50 I1Y Average and RMS of Measurements VT = -212.447 +- 4.748 uVs I1Y = -42.484 +- 0.950 uTm 16:37:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:37:55 Integrated Voltage Measurement... 16:38:04 Voltage Offset Correction: v_off_ini = 735.279 uV, v_off_fin = 745.413 uV 16:38:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.911 uVs 16:38:04 Integrated Voltage Measurement... 16:38:13 Voltage Offset Correction: v_off_ini = 750.062 uV, v_off_fin = 754.536 uV 16:38:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.051 uVs 16:38:13 Integrated Voltage Measurement... 16:38:22 Voltage Offset Correction: v_off_ini = 761.423 uV, v_off_fin = 739.940 uV 16:38:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.434 uVs 16:38:23 Integrated Voltage Measurement... 16:38:31 Voltage Offset Correction: v_off_ini = 752.228 uV, v_off_fin = 764.195 uV 16:38:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.098 uVs 16:38:32 Integrated Voltage Measurement... 16:38:41 Voltage Offset Correction: v_off_ini = 759.401 uV, v_off_fin = 756.428 uV 16:38:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.569 uVs 16:38:41 Integrated Voltage Measurement... 16:38:50 Voltage Offset Correction: v_off_ini = 754.144 uV, v_off_fin = 748.667 uV 16:38:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.677 uVs 16:38:52 I2X Average and RMS of Measurements VT = -100.457 +- 3.454 uVs I2X = 9.242 +- 0.318 uTm^2 16:38:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:38:57 Integrated Voltage Measurement... 16:39:06 Voltage Offset Correction: v_off_ini = 738.647 uV, v_off_fin = 736.327 uV 16:39:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -470.863 uVs 16:39:06 Integrated Voltage Measurement... 16:39:15 Voltage Offset Correction: v_off_ini = 740.401 uV, v_off_fin = 745.865 uV 16:39:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.260 uVs 16:39:15 Integrated Voltage Measurement... 16:39:24 Voltage Offset Correction: v_off_ini = 745.346 uV, v_off_fin = 743.457 uV 16:39:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.566 uVs 16:39:24 Integrated Voltage Measurement... 16:39:33 Voltage Offset Correction: v_off_ini = 745.055 uV, v_off_fin = 728.992 uV 16:39:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 494.788 uVs 16:39:33 Integrated Voltage Measurement... 16:39:42 Voltage Offset Correction: v_off_ini = 728.326 uV, v_off_fin = 720.949 uV 16:39:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -490.543 uVs 16:39:42 Integrated Voltage Measurement... 16:39:51 Voltage Offset Correction: v_off_ini = 729.959 uV, v_off_fin = 731.162 uV 16:39:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.574 uVs 16:39:54 I2Y Average and RMS of Measurements VT = -488.099 +- 4.630 uVs I2Y = -44.906 +- 0.425 uTm^2 16:40:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:40:15 Integrated Voltage Measurement... 16:40:24 Voltage Offset Correction: v_off_ini = 745.203 uV, v_off_fin = 732.683 uV 16:40:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.672 uVs 16:40:24 Integrated Voltage Measurement... 16:40:33 Voltage Offset Correction: v_off_ini = 743.798 uV, v_off_fin = 728.671 uV 16:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.170 uVs 16:40:33 Integrated Voltage Measurement... 16:40:42 Voltage Offset Correction: v_off_ini = 729.334 uV, v_off_fin = 739.064 uV 16:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.809 uVs 16:40:42 Integrated Voltage Measurement... 16:40:51 Voltage Offset Correction: v_off_ini = 743.325 uV, v_off_fin = 734.960 uV 16:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.233 uVs 16:40:51 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = 734.045 uV, v_off_fin = 730.475 uV 16:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.227 uVs 16:41:00 Integrated Voltage Measurement... 16:41:09 Voltage Offset Correction: v_off_ini = 750.143 uV, v_off_fin = 743.719 uV 16:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.707 uVs 16:41:14 I1X Average and RMS of Measurements VT = -128.970 +- 6.510 uVs I1X = 25.794 +- 1.302 uTm 16:41:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:41:20 Integrated Voltage Measurement... 16:41:29 Voltage Offset Correction: v_off_ini = 741.888 uV, v_off_fin = 729.829 uV 16:41:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.715 uVs 16:41:29 Integrated Voltage Measurement... 16:41:38 Voltage Offset Correction: v_off_ini = 745.723 uV, v_off_fin = 750.493 uV 16:41:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.185 uVs 16:41:38 Integrated Voltage Measurement... 16:41:47 Voltage Offset Correction: v_off_ini = 741.712 uV, v_off_fin = 734.958 uV 16:41:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.878 uVs 16:41:47 Integrated Voltage Measurement... 16:41:56 Voltage Offset Correction: v_off_ini = 730.861 uV, v_off_fin = 739.980 uV 16:41:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.312 uVs 16:41:56 Integrated Voltage Measurement... 16:42:05 Voltage Offset Correction: v_off_ini = 727.551 uV, v_off_fin = 721.326 uV 16:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.054 uVs 16:42:05 Integrated Voltage Measurement... 16:42:14 Voltage Offset Correction: v_off_ini = 747.316 uV, v_off_fin = 742.923 uV 16:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.539 uVs 16:42:19 I1Y Average and RMS of Measurements VT = -213.947 +- 4.857 uVs I1Y = -42.789 +- 0.971 uTm 16:42:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:42:26 Integrated Voltage Measurement... 16:42:35 Voltage Offset Correction: v_off_ini = 738.206 uV, v_off_fin = 725.753 uV 16:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.341 uVs 16:42:35 Integrated Voltage Measurement... 16:42:44 Voltage Offset Correction: v_off_ini = 742.149 uV, v_off_fin = 741.199 uV 16:42:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.417 uVs 16:42:44 Integrated Voltage Measurement... 16:42:53 Voltage Offset Correction: v_off_ini = 736.025 uV, v_off_fin = 724.203 uV 16:42:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.472 uVs 16:42:53 Integrated Voltage Measurement... 16:43:02 Voltage Offset Correction: v_off_ini = 730.052 uV, v_off_fin = 736.796 uV 16:43:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.346 uVs 16:43:02 Integrated Voltage Measurement... 16:43:11 Voltage Offset Correction: v_off_ini = 734.943 uV, v_off_fin = 721.659 uV 16:43:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.394 uVs 16:43:11 Integrated Voltage Measurement... 16:43:20 Voltage Offset Correction: v_off_ini = 734.905 uV, v_off_fin = 726.005 uV 16:43:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.534 uVs 16:43:23 I2X Average and RMS of Measurements VT = -120.751 +- 8.895 uVs I2X = 11.109 +- 0.819 uTm^2 16:43:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:43:31 Integrated Voltage Measurement... 16:43:40 Voltage Offset Correction: v_off_ini = 714.844 uV, v_off_fin = 721.283 uV 16:43:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -464.856 uVs 16:43:40 Integrated Voltage Measurement... 16:43:49 Voltage Offset Correction: v_off_ini = 735.006 uV, v_off_fin = 727.052 uV 16:43:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.829 uVs 16:43:49 Integrated Voltage Measurement... 16:43:58 Voltage Offset Correction: v_off_ini = 717.036 uV, v_off_fin = 719.367 uV 16:43:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.065 uVs 16:43:58 Integrated Voltage Measurement... 16:44:07 Voltage Offset Correction: v_off_ini = 720.744 uV, v_off_fin = 726.511 uV 16:44:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 466.327 uVs 16:44:07 Integrated Voltage Measurement... 16:44:16 Voltage Offset Correction: v_off_ini = 722.296 uV, v_off_fin = 734.215 uV 16:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.472 uVs 16:44:16 Integrated Voltage Measurement... 16:44:25 Voltage Offset Correction: v_off_ini = 720.545 uV, v_off_fin = 724.857 uV 16:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.627 uVs 16:44:27 I2Y Average and RMS of Measurements VT = -461.363 +- 10.774 uVs I2Y = -42.445 +- 0.991 uTm^2 16:44:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:44:36 Integrated Voltage Measurement... 16:44:45 Voltage Offset Correction: v_off_ini = 744.790 uV, v_off_fin = 728.940 uV 16:44:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -158.222 uVs 16:44:45 Integrated Voltage Measurement... 16:44:54 Voltage Offset Correction: v_off_ini = 736.430 uV, v_off_fin = 747.835 uV 16:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.421 uVs 16:44:54 Integrated Voltage Measurement... 16:45:03 Voltage Offset Correction: v_off_ini = 739.336 uV, v_off_fin = 742.160 uV 16:45:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.436 uVs 16:45:03 Integrated Voltage Measurement... 16:45:12 Voltage Offset Correction: v_off_ini = 746.197 uV, v_off_fin = 762.438 uV 16:45:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.917 uVs 16:45:12 Integrated Voltage Measurement... 16:45:21 Voltage Offset Correction: v_off_ini = 747.645 uV, v_off_fin = 756.639 uV 16:45:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.462 uVs 16:45:21 Integrated Voltage Measurement... 16:45:30 Voltage Offset Correction: v_off_ini = 745.836 uV, v_off_fin = 758.256 uV 16:45:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.212 uVs 16:45:35 I1X Average and RMS of Measurements VT = -137.278 +- 6.047 uVs I1X = 27.458 +- 1.210 uTm 16:45:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:45:41 Integrated Voltage Measurement... 16:45:50 Voltage Offset Correction: v_off_ini = 756.852 uV, v_off_fin = 751.432 uV 16:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.645 uVs 16:45:50 Integrated Voltage Measurement... 16:45:59 Voltage Offset Correction: v_off_ini = 747.368 uV, v_off_fin = 754.199 uV 16:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.587 uVs 16:45:59 Integrated Voltage Measurement... 16:46:08 Voltage Offset Correction: v_off_ini = 748.702 uV, v_off_fin = 738.052 uV 16:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.311 uVs 16:46:08 Integrated Voltage Measurement... 16:46:17 Voltage Offset Correction: v_off_ini = 745.729 uV, v_off_fin = 754.306 uV 16:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.829 uVs 16:46:17 Integrated Voltage Measurement... 16:46:26 Voltage Offset Correction: v_off_ini = 742.319 uV, v_off_fin = 737.594 uV 16:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.784 uVs 16:46:26 Integrated Voltage Measurement... 16:46:35 Voltage Offset Correction: v_off_ini = 744.857 uV, v_off_fin = 733.415 uV 16:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.117 uVs 16:46:40 I1Y Average and RMS of Measurements VT = -219.879 +- 5.569 uVs I1Y = -43.976 +- 1.114 uTm 16:46:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:46:47 Integrated Voltage Measurement... 16:46:56 Voltage Offset Correction: v_off_ini = 746.628 uV, v_off_fin = 731.429 uV 16:46:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.997 uVs 16:46:56 Integrated Voltage Measurement... 16:47:05 Voltage Offset Correction: v_off_ini = 722.544 uV, v_off_fin = 725.610 uV 16:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.681 uVs 16:47:05 Integrated Voltage Measurement... 16:47:14 Voltage Offset Correction: v_off_ini = 720.912 uV, v_off_fin = 710.599 uV 16:47:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.524 uVs 16:47:15 Integrated Voltage Measurement... 16:47:24 Voltage Offset Correction: v_off_ini = 733.669 uV, v_off_fin = 737.006 uV 16:47:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.728 uVs 16:47:24 Integrated Voltage Measurement... 16:47:33 Voltage Offset Correction: v_off_ini = 737.763 uV, v_off_fin = 729.577 uV 16:47:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.921 uVs 16:47:33 Integrated Voltage Measurement... 16:47:42 Voltage Offset Correction: v_off_ini = 739.166 uV, v_off_fin = 744.860 uV 16:47:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.567 uVs 16:47:44 I2X Average and RMS of Measurements VT = -128.736 +- 6.952 uVs I2X = 11.844 +- 0.640 uTm^2 16:47:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:47:52 Integrated Voltage Measurement... 16:48:01 Voltage Offset Correction: v_off_ini = 747.215 uV, v_off_fin = 731.758 uV 16:48:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.482 uVs 16:48:01 Integrated Voltage Measurement... 16:48:10 Voltage Offset Correction: v_off_ini = 746.355 uV, v_off_fin = 740.497 uV 16:48:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 498.585 uVs 16:48:10 Integrated Voltage Measurement... 16:48:19 Voltage Offset Correction: v_off_ini = 746.639 uV, v_off_fin = 743.582 uV 16:48:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.827 uVs 16:48:19 Integrated Voltage Measurement... 16:48:28 Voltage Offset Correction: v_off_ini = 730.035 uV, v_off_fin = 741.516 uV 16:48:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.305 uVs 16:48:28 Integrated Voltage Measurement... 16:48:37 Voltage Offset Correction: v_off_ini = 736.581 uV, v_off_fin = 738.009 uV 16:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -477.851 uVs 16:48:37 Integrated Voltage Measurement... 16:48:46 Voltage Offset Correction: v_off_ini = 735.059 uV, v_off_fin = 727.568 uV 16:48:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.175 uVs 16:48:48 I2Y Average and RMS of Measurements VT = -480.371 +- 4.873 uVs I2Y = -44.194 +- 0.448 uTm^2 16:48:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:57 Integrated Voltage Measurement... 16:49:06 Voltage Offset Correction: v_off_ini = 740.116 uV, v_off_fin = 737.826 uV 16:49:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -151.253 uVs 16:49:06 Integrated Voltage Measurement... 16:49:15 Voltage Offset Correction: v_off_ini = 749.747 uV, v_off_fin = 750.465 uV 16:49:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.349 uVs 16:49:15 Integrated Voltage Measurement... 16:49:24 Voltage Offset Correction: v_off_ini = 734.523 uV, v_off_fin = 737.348 uV 16:49:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.495 uVs 16:49:24 Integrated Voltage Measurement... 16:49:33 Voltage Offset Correction: v_off_ini = 745.784 uV, v_off_fin = 748.093 uV 16:49:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.692 uVs 16:49:34 Integrated Voltage Measurement... 16:49:42 Voltage Offset Correction: v_off_ini = 738.742 uV, v_off_fin = 742.833 uV 16:49:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.758 uVs 16:49:43 Integrated Voltage Measurement... 16:49:51 Voltage Offset Correction: v_off_ini = 750.156 uV, v_off_fin = 746.296 uV 16:49:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.463 uVs 16:49:56 I1X Average and RMS of Measurements VT = -131.168 +- 5.197 uVs I1X = 26.235 +- 1.040 uTm 16:49:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:03 Integrated Voltage Measurement... 16:50:11 Voltage Offset Correction: v_off_ini = 726.262 uV, v_off_fin = 743.404 uV 16:50:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.923 uVs 16:50:12 Integrated Voltage Measurement... 16:50:21 Voltage Offset Correction: v_off_ini = 745.194 uV, v_off_fin = 757.656 uV 16:50:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.950 uVs 16:50:21 Integrated Voltage Measurement... 16:50:30 Voltage Offset Correction: v_off_ini = 749.015 uV, v_off_fin = 741.109 uV 16:50:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.341 uVs 16:50:30 Integrated Voltage Measurement... 16:50:39 Voltage Offset Correction: v_off_ini = 740.926 uV, v_off_fin = 753.009 uV 16:50:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.288 uVs 16:50:39 Integrated Voltage Measurement... 16:50:48 Voltage Offset Correction: v_off_ini = 748.686 uV, v_off_fin = 720.716 uV 16:50:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.800 uVs 16:50:48 Integrated Voltage Measurement... 16:50:57 Voltage Offset Correction: v_off_ini = 736.159 uV, v_off_fin = 749.306 uV 16:50:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.456 uVs 16:51:01 I1Y Average and RMS of Measurements VT = -213.960 +- 2.369 uVs I1Y = -42.792 +- 0.474 uTm 16:51:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:09 Integrated Voltage Measurement... 16:51:18 Voltage Offset Correction: v_off_ini = 729.207 uV, v_off_fin = 730.152 uV 16:51:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.740 uVs 16:51:18 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 728.896 uV, v_off_fin = 746.392 uV 16:51:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.944 uVs 16:51:27 Integrated Voltage Measurement... 16:51:36 Voltage Offset Correction: v_off_ini = 739.322 uV, v_off_fin = 716.694 uV 16:51:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.959 uVs 16:51:36 Integrated Voltage Measurement... 16:51:45 Voltage Offset Correction: v_off_ini = 740.203 uV, v_off_fin = 732.968 uV 16:51:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.923 uVs 16:51:45 Integrated Voltage Measurement... 16:51:54 Voltage Offset Correction: v_off_ini = 711.913 uV, v_off_fin = 715.815 uV 16:51:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.895 uVs 16:51:54 Integrated Voltage Measurement... 16:52:03 Voltage Offset Correction: v_off_ini = 724.990 uV, v_off_fin = 735.695 uV 16:52:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.674 uVs 16:52:05 I2X Average and RMS of Measurements VT = -126.023 +- 7.058 uVs I2X = 11.594 +- 0.649 uTm^2 16:52:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:13 Integrated Voltage Measurement... 16:52:22 Voltage Offset Correction: v_off_ini = 729.528 uV, v_off_fin = 730.584 uV 16:52:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -464.972 uVs 16:52:22 Integrated Voltage Measurement... 16:52:31 Voltage Offset Correction: v_off_ini = 730.323 uV, v_off_fin = 726.438 uV 16:52:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 469.277 uVs 16:52:31 Integrated Voltage Measurement... 16:52:40 Voltage Offset Correction: v_off_ini = 735.002 uV, v_off_fin = 721.700 uV 16:52:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.264 uVs 16:52:40 Integrated Voltage Measurement... 16:52:49 Voltage Offset Correction: v_off_ini = 704.370 uV, v_off_fin = 721.189 uV 16:52:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.786 uVs 16:52:49 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = 724.072 uV, v_off_fin = 717.947 uV 16:52:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -471.246 uVs 16:52:58 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = 728.182 uV, v_off_fin = 749.716 uV 16:53:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 461.534 uVs 16:53:10 I2Y Average and RMS of Measurements VT = -466.680 +- 0.319 uVs I2Y = -42.935 +- 0.029 uTm^2 16:53:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:53:19 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = 744.389 uV, v_off_fin = 727.191 uV 16:53:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.022 uVs 16:53:28 Integrated Voltage Measurement... 16:53:37 Voltage Offset Correction: v_off_ini = 741.511 uV, v_off_fin = 729.146 uV 16:53:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.443 uVs 16:53:37 Integrated Voltage Measurement... 16:53:46 Voltage Offset Correction: v_off_ini = 730.951 uV, v_off_fin = 715.376 uV 16:53:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.528 uVs 16:53:46 Integrated Voltage Measurement... 16:53:55 Voltage Offset Correction: v_off_ini = 724.629 uV, v_off_fin = 728.696 uV 16:53:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.006 uVs 16:53:55 Integrated Voltage Measurement... 16:54:04 Voltage Offset Correction: v_off_ini = 693.661 uV, v_off_fin = 700.054 uV 16:54:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.909 uVs 16:54:04 Integrated Voltage Measurement... 16:54:13 Voltage Offset Correction: v_off_ini = 707.537 uV, v_off_fin = 707.371 uV 16:54:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.594 uVs 16:54:17 I1X Average and RMS of Measurements VT = -137.750 +- 9.323 uVs I1X = 27.550 +- 1.865 uTm 16:54:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:54:24 Integrated Voltage Measurement... 16:54:33 Voltage Offset Correction: v_off_ini = 699.795 uV, v_off_fin = 692.477 uV 16:54:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.268 uVs 16:54:33 Integrated Voltage Measurement... 16:54:42 Voltage Offset Correction: v_off_ini = 700.537 uV, v_off_fin = 697.888 uV 16:54:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.724 uVs 16:54:42 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = 699.320 uV, v_off_fin = 688.743 uV 16:54:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.771 uVs 16:54:51 Integrated Voltage Measurement... 16:55:00 Voltage Offset Correction: v_off_ini = 697.395 uV, v_off_fin = 704.472 uV 16:55:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.705 uVs 16:55:00 Integrated Voltage Measurement... 16:55:09 Voltage Offset Correction: v_off_ini = 700.257 uV, v_off_fin = 700.892 uV 16:55:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.493 uVs 16:55:09 Integrated Voltage Measurement... 16:55:18 Voltage Offset Correction: v_off_ini = 700.409 uV, v_off_fin = 700.263 uV 16:55:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.861 uVs 16:55:22 I1Y Average and RMS of Measurements VT = -218.304 +- 3.593 uVs I1Y = -43.661 +- 0.719 uTm 16:55:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:55:30 Integrated Voltage Measurement... 16:55:39 Voltage Offset Correction: v_off_ini = 678.918 uV, v_off_fin = 682.439 uV 16:55:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.226 uVs 16:55:39 Integrated Voltage Measurement... 16:55:48 Voltage Offset Correction: v_off_ini = 702.155 uV, v_off_fin = 703.060 uV 16:55:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.361 uVs 16:55:48 Integrated Voltage Measurement... 16:55:57 Voltage Offset Correction: v_off_ini = 706.072 uV, v_off_fin = 672.902 uV 16:55:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.973 uVs 16:55:57 Integrated Voltage Measurement... 16:56:06 Voltage Offset Correction: v_off_ini = 682.195 uV, v_off_fin = 689.720 uV 16:56:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.995 uVs 16:56:06 Integrated Voltage Measurement... 16:56:15 Voltage Offset Correction: v_off_ini = 696.154 uV, v_off_fin = 689.924 uV 16:56:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -134.295 uVs 16:56:15 Integrated Voltage Measurement... 16:56:24 Voltage Offset Correction: v_off_ini = 692.115 uV, v_off_fin = 696.772 uV 16:56:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.254 uVs 16:56:26 I2X Average and RMS of Measurements VT = -122.351 +- 5.213 uVs I2X = 11.256 +- 0.480 uTm^2 16:56:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:56:34 Integrated Voltage Measurement... 16:56:43 Voltage Offset Correction: v_off_ini = 692.068 uV, v_off_fin = 687.891 uV 16:56:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -480.239 uVs 16:56:43 Integrated Voltage Measurement... 16:56:52 Voltage Offset Correction: v_off_ini = 694.452 uV, v_off_fin = 692.350 uV 16:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.841 uVs 16:56:52 Integrated Voltage Measurement... 16:57:01 Voltage Offset Correction: v_off_ini = 686.409 uV, v_off_fin = 685.428 uV 16:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.977 uVs 16:57:01 Integrated Voltage Measurement... 16:57:10 Voltage Offset Correction: v_off_ini = 703.101 uV, v_off_fin = 692.630 uV 16:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.496 uVs 16:57:10 Integrated Voltage Measurement... 16:57:19 Voltage Offset Correction: v_off_ini = 690.486 uV, v_off_fin = 676.421 uV 16:57:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -483.103 uVs 16:57:19 Integrated Voltage Measurement... 16:57:28 Voltage Offset Correction: v_off_ini = 677.006 uV, v_off_fin = 672.435 uV 16:57:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.926 uVs 16:57:31 I2Y Average and RMS of Measurements VT = -470.930 +- 12.529 uVs I2Y = -43.326 +- 1.153 uTm^2 16:57:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:57:40 Integrated Voltage Measurement... 16:57:49 Voltage Offset Correction: v_off_ini = 677.317 uV, v_off_fin = 679.517 uV 16:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.439 uVs 16:57:49 Integrated Voltage Measurement... 16:57:58 Voltage Offset Correction: v_off_ini = 658.685 uV, v_off_fin = 666.526 uV 16:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.593 uVs 16:57:58 Integrated Voltage Measurement... 16:58:07 Voltage Offset Correction: v_off_ini = 671.381 uV, v_off_fin = 668.337 uV 16:58:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -141.976 uVs 16:58:07 Integrated Voltage Measurement... 16:58:16 Voltage Offset Correction: v_off_ini = 676.472 uV, v_off_fin = 678.853 uV 16:58:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 136.816 uVs 16:58:16 Integrated Voltage Measurement... 16:58:25 Voltage Offset Correction: v_off_ini = 679.969 uV, v_off_fin = 665.459 uV 16:58:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.856 uVs 16:58:25 Integrated Voltage Measurement... 16:58:34 Voltage Offset Correction: v_off_ini = 676.467 uV, v_off_fin = 675.737 uV 16:58:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.238 uVs 16:58:38 I1X Average and RMS of Measurements VT = -144.653 +- 6.324 uVs I1X = 28.932 +- 1.264 uTm 16:58:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:58:45 Integrated Voltage Measurement... 16:58:54 Voltage Offset Correction: v_off_ini = 702.710 uV, v_off_fin = 692.873 uV 16:58:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.651 uVs 16:58:54 Integrated Voltage Measurement... 16:59:03 Voltage Offset Correction: v_off_ini = 695.518 uV, v_off_fin = 692.896 uV 16:59:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.958 uVs 16:59:03 Integrated Voltage Measurement... 16:59:12 Voltage Offset Correction: v_off_ini = 694.076 uV, v_off_fin = 688.624 uV 16:59:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.455 uVs 16:59:12 Integrated Voltage Measurement... 16:59:21 Voltage Offset Correction: v_off_ini = 703.301 uV, v_off_fin = 699.961 uV 16:59:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.491 uVs 16:59:21 Integrated Voltage Measurement... 16:59:30 Voltage Offset Correction: v_off_ini = 697.555 uV, v_off_fin = 694.061 uV 16:59:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.447 uVs 16:59:30 Integrated Voltage Measurement... 16:59:39 Voltage Offset Correction: v_off_ini = 702.933 uV, v_off_fin = 720.441 uV 16:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.328 uVs 16:59:43 I1Y Average and RMS of Measurements VT = -210.055 +- 8.539 uVs I1Y = -42.011 +- 1.708 uTm 16:59:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:59:51 Integrated Voltage Measurement... 17:00:00 Voltage Offset Correction: v_off_ini = 711.735 uV, v_off_fin = 707.038 uV 17:00:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.285 uVs 17:00:00 Integrated Voltage Measurement... 17:00:09 Voltage Offset Correction: v_off_ini = 701.544 uV, v_off_fin = 718.289 uV 17:00:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.312 uVs 17:00:09 Integrated Voltage Measurement... 17:00:18 Voltage Offset Correction: v_off_ini = 716.537 uV, v_off_fin = 700.460 uV 17:00:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.498 uVs 17:00:18 Integrated Voltage Measurement... 17:00:27 Voltage Offset Correction: v_off_ini = 685.119 uV, v_off_fin = 702.255 uV 17:00:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.899 uVs 17:00:27 Integrated Voltage Measurement... 17:00:36 Voltage Offset Correction: v_off_ini = 701.223 uV, v_off_fin = 682.130 uV 17:00:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.280 uVs 17:00:36 Integrated Voltage Measurement... 17:00:45 Voltage Offset Correction: v_off_ini = 704.348 uV, v_off_fin = 701.652 uV 17:00:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.121 uVs 17:00:47 I2X Average and RMS of Measurements VT = -123.399 +- 6.982 uVs I2X = 11.353 +- 0.642 uTm^2 17:00:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:00:55 Integrated Voltage Measurement... 17:01:04 Voltage Offset Correction: v_off_ini = 700.914 uV, v_off_fin = 693.826 uV 17:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.583 uVs 17:01:04 Integrated Voltage Measurement... 17:01:13 Voltage Offset Correction: v_off_ini = 702.553 uV, v_off_fin = 706.375 uV 17:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 477.548 uVs 17:01:13 Integrated Voltage Measurement... 17:01:22 Voltage Offset Correction: v_off_ini = 701.897 uV, v_off_fin = 697.485 uV 17:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.698 uVs 17:01:22 Integrated Voltage Measurement... 17:01:31 Voltage Offset Correction: v_off_ini = 706.574 uV, v_off_fin = 700.648 uV 17:01:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.201 uVs 17:01:31 Integrated Voltage Measurement... 17:01:40 Voltage Offset Correction: v_off_ini = 699.446 uV, v_off_fin = 709.758 uV 17:01:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.740 uVs 17:01:40 Integrated Voltage Measurement... 17:01:49 Voltage Offset Correction: v_off_ini = 712.141 uV, v_off_fin = 703.022 uV 17:01:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 461.423 uVs 17:01:52 I2Y Average and RMS of Measurements VT = -463.532 +- 4.852 uVs I2Y = -42.645 +- 0.446 uTm^2 17:01:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:02:04 Integrated Voltage Measurement... 17:02:13 Voltage Offset Correction: v_off_ini = 701.585 uV, v_off_fin = 684.340 uV 17:02:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -139.289 uVs 17:02:13 Integrated Voltage Measurement... 17:02:22 Voltage Offset Correction: v_off_ini = 685.561 uV, v_off_fin = 699.326 uV 17:02:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.913 uVs 17:02:22 Integrated Voltage Measurement... 17:02:31 Voltage Offset Correction: v_off_ini = 697.188 uV, v_off_fin = 692.215 uV 17:02:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.996 uVs 17:02:31 Integrated Voltage Measurement... 17:02:40 Voltage Offset Correction: v_off_ini = 692.049 uV, v_off_fin = 703.166 uV 17:02:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.302 uVs 17:02:40 Integrated Voltage Measurement... 17:02:49 Voltage Offset Correction: v_off_ini = 691.694 uV, v_off_fin = 684.788 uV 17:02:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.848 uVs 17:02:49 Integrated Voltage Measurement... 17:02:58 Voltage Offset Correction: v_off_ini = 682.010 uV, v_off_fin = 684.775 uV 17:02:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.683 uVs 17:03:02 I1X Average and RMS of Measurements VT = -125.672 +- 6.510 uVs I1X = 25.135 +- 1.303 uTm 17:03:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:03:09 Integrated Voltage Measurement... 17:03:18 Voltage Offset Correction: v_off_ini = 683.106 uV, v_off_fin = 679.066 uV 17:03:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.068 uVs 17:03:18 Integrated Voltage Measurement... 17:03:27 Voltage Offset Correction: v_off_ini = 694.810 uV, v_off_fin = 698.952 uV 17:03:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.805 uVs 17:03:27 Integrated Voltage Measurement... 17:03:36 Voltage Offset Correction: v_off_ini = 684.934 uV, v_off_fin = 679.130 uV 17:03:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.855 uVs 17:03:36 Integrated Voltage Measurement... 17:03:45 Voltage Offset Correction: v_off_ini = 693.931 uV, v_off_fin = 704.191 uV 17:03:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.852 uVs 17:03:45 Integrated Voltage Measurement... 17:03:54 Voltage Offset Correction: v_off_ini = 666.689 uV, v_off_fin = 666.518 uV 17:03:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.418 uVs 17:03:54 Integrated Voltage Measurement... 17:04:03 Voltage Offset Correction: v_off_ini = 688.338 uV, v_off_fin = 699.066 uV 17:04:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.888 uVs 17:04:07 I1Y Average and RMS of Measurements VT = -214.481 +- 6.622 uVs I1Y = -42.896 +- 1.324 uTm 17:04:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:04:12 Integrated Voltage Measurement... 17:04:21 Voltage Offset Correction: v_off_ini = 682.069 uV, v_off_fin = 687.933 uV 17:04:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.659 uVs 17:04:21 Integrated Voltage Measurement... 17:04:30 Voltage Offset Correction: v_off_ini = 707.260 uV, v_off_fin = 714.691 uV 17:04:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.592 uVs 17:04:30 Integrated Voltage Measurement... 17:04:39 Voltage Offset Correction: v_off_ini = 697.008 uV, v_off_fin = 680.504 uV 17:04:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.605 uVs 17:04:39 Integrated Voltage Measurement... 17:04:48 Voltage Offset Correction: v_off_ini = 697.859 uV, v_off_fin = 703.108 uV 17:04:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.121 uVs 17:04:49 Integrated Voltage Measurement... 17:04:58 Voltage Offset Correction: v_off_ini = 716.339 uV, v_off_fin = 692.702 uV 17:04:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.004 uVs 17:04:58 Integrated Voltage Measurement... 17:05:07 Voltage Offset Correction: v_off_ini = 704.539 uV, v_off_fin = 719.695 uV 17:05:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.478 uVs 17:05:09 I2X Average and RMS of Measurements VT = -103.243 +- 5.046 uVs I2X = 9.498 +- 0.464 uTm^2 17:05:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:05:14 Integrated Voltage Measurement... 17:05:23 Voltage Offset Correction: v_off_ini = 713.893 uV, v_off_fin = 714.027 uV 17:05:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -473.571 uVs 17:05:23 Integrated Voltage Measurement... 17:05:32 Voltage Offset Correction: v_off_ini = 711.281 uV, v_off_fin = 713.262 uV 17:05:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.568 uVs 17:05:32 Integrated Voltage Measurement... 17:05:41 Voltage Offset Correction: v_off_ini = 719.426 uV, v_off_fin = 704.651 uV 17:05:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -459.008 uVs 17:05:41 Integrated Voltage Measurement... 17:05:50 Voltage Offset Correction: v_off_ini = 714.535 uV, v_off_fin = 719.070 uV 17:05:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 463.527 uVs 17:05:50 Integrated Voltage Measurement... 17:05:59 Voltage Offset Correction: v_off_ini = 730.105 uV, v_off_fin = 725.512 uV 17:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -464.557 uVs 17:05:59 Integrated Voltage Measurement... 17:06:08 Voltage Offset Correction: v_off_ini = 728.157 uV, v_off_fin = 726.177 uV 17:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.452 uVs 17:06:11 I2Y Average and RMS of Measurements VT = -462.281 +- 8.426 uVs I2Y = -42.531 +- 0.775 uTm^2 17:06:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:06:19 Integrated Voltage Measurement... 17:06:28 Voltage Offset Correction: v_off_ini = 727.080 uV, v_off_fin = 723.964 uV 17:06:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.656 uVs 17:06:28 Integrated Voltage Measurement... 17:06:37 Voltage Offset Correction: v_off_ini = 725.080 uV, v_off_fin = 731.678 uV 17:06:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.056 uVs 17:06:37 Integrated Voltage Measurement... 17:06:46 Voltage Offset Correction: v_off_ini = 724.060 uV, v_off_fin = 727.427 uV 17:06:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.931 uVs 17:06:46 Integrated Voltage Measurement... 17:06:55 Voltage Offset Correction: v_off_ini = 717.790 uV, v_off_fin = 722.391 uV 17:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.241 uVs 17:06:55 Integrated Voltage Measurement... 17:07:04 Voltage Offset Correction: v_off_ini = 721.990 uV, v_off_fin = 729.522 uV 17:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.710 uVs 17:07:04 Integrated Voltage Measurement... 17:07:13 Voltage Offset Correction: v_off_ini = 734.432 uV, v_off_fin = 732.262 uV 17:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.566 uVs 17:07:17 I1X Average and RMS of Measurements VT = -133.527 +- 3.493 uVs I1X = 26.706 +- 0.699 uTm 17:07:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:07:24 Integrated Voltage Measurement... 17:07:33 Voltage Offset Correction: v_off_ini = 729.771 uV, v_off_fin = 718.994 uV 17:07:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.982 uVs 17:07:33 Integrated Voltage Measurement... 17:07:42 Voltage Offset Correction: v_off_ini = 732.830 uV, v_off_fin = 739.947 uV 17:07:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.375 uVs 17:07:42 Integrated Voltage Measurement... 17:07:51 Voltage Offset Correction: v_off_ini = 737.009 uV, v_off_fin = 725.474 uV 17:07:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.314 uVs 17:07:51 Integrated Voltage Measurement... 17:08:00 Voltage Offset Correction: v_off_ini = 749.947 uV, v_off_fin = 746.383 uV 17:08:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.119 uVs 17:08:00 Integrated Voltage Measurement... 17:08:09 Voltage Offset Correction: v_off_ini = 734.450 uV, v_off_fin = 722.804 uV 17:08:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.450 uVs 17:08:09 Integrated Voltage Measurement... 17:08:18 Voltage Offset Correction: v_off_ini = 733.208 uV, v_off_fin = 739.664 uV 17:08:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.378 uVs 17:08:22 I1Y Average and RMS of Measurements VT = -216.436 +- 1.968 uVs I1Y = -43.288 +- 0.394 uTm 17:08:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:08:28 Integrated Voltage Measurement... 17:08:37 Voltage Offset Correction: v_off_ini = 740.429 uV, v_off_fin = 736.636 uV 17:08:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.771 uVs 17:08:37 Integrated Voltage Measurement... 17:08:46 Voltage Offset Correction: v_off_ini = 747.602 uV, v_off_fin = 755.675 uV 17:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.835 uVs 17:08:46 Integrated Voltage Measurement... 17:08:55 Voltage Offset Correction: v_off_ini = 747.700 uV, v_off_fin = 735.749 uV 17:08:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.755 uVs 17:08:55 Integrated Voltage Measurement... 17:09:04 Voltage Offset Correction: v_off_ini = 724.817 uV, v_off_fin = 736.186 uV 17:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.991 uVs 17:09:04 Integrated Voltage Measurement... 17:09:13 Voltage Offset Correction: v_off_ini = 732.373 uV, v_off_fin = 731.639 uV 17:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.407 uVs 17:09:13 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = 750.139 uV, v_off_fin = 757.105 uV 17:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.632 uVs 17:09:24 I2X Average and RMS of Measurements VT = -112.065 +- 3.730 uVs I2X = 10.310 +- 0.343 uTm^2 17:09:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:09:29 Integrated Voltage Measurement... 17:09:38 Voltage Offset Correction: v_off_ini = 738.781 uV, v_off_fin = 736.225 uV 17:09:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -448.631 uVs 17:09:38 Integrated Voltage Measurement... 17:09:47 Voltage Offset Correction: v_off_ini = 741.873 uV, v_off_fin = 735.671 uV 17:09:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.733 uVs 17:09:47 Integrated Voltage Measurement... 17:09:56 Voltage Offset Correction: v_off_ini = 744.215 uV, v_off_fin = 744.771 uV 17:09:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.075 uVs 17:09:56 Integrated Voltage Measurement... 17:10:05 Voltage Offset Correction: v_off_ini = 736.691 uV, v_off_fin = 734.550 uV 17:10:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.869 uVs 17:10:06 Integrated Voltage Measurement... 17:10:15 Voltage Offset Correction: v_off_ini = 731.541 uV, v_off_fin = 732.468 uV 17:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -469.312 uVs 17:10:15 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = 738.162 uV, v_off_fin = 724.996 uV 17:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 456.847 uVs 17:10:26 I2Y Average and RMS of Measurements VT = -464.745 +- 11.406 uVs I2Y = -42.757 +- 1.049 uTm^2 17:10:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:34 Integrated Voltage Measurement... 17:10:43 Voltage Offset Correction: v_off_ini = 747.186 uV, v_off_fin = 712.435 uV 17:10:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.334 uVs 17:10:43 Integrated Voltage Measurement... 17:10:52 Voltage Offset Correction: v_off_ini = 734.045 uV, v_off_fin = 744.659 uV 17:10:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.916 uVs 17:10:52 Integrated Voltage Measurement... 17:11:01 Voltage Offset Correction: v_off_ini = 734.019 uV, v_off_fin = 729.793 uV 17:11:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.092 uVs 17:11:01 Integrated Voltage Measurement... 17:11:10 Voltage Offset Correction: v_off_ini = 731.815 uV, v_off_fin = 730.643 uV 17:11:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.484 uVs 17:11:10 Integrated Voltage Measurement... 17:11:19 Voltage Offset Correction: v_off_ini = 742.359 uV, v_off_fin = 732.299 uV 17:11:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.459 uVs 17:11:19 Integrated Voltage Measurement... 17:11:28 Voltage Offset Correction: v_off_ini = 729.213 uV, v_off_fin = 735.285 uV 17:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 148.526 uVs 17:11:33 I1X Average and RMS of Measurements VT = -139.135 +- 6.060 uVs I1X = 27.828 +- 1.212 uTm 17:11:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:39 Integrated Voltage Measurement... 17:11:48 Voltage Offset Correction: v_off_ini = 724.757 uV, v_off_fin = 719.923 uV 17:11:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.859 uVs 17:11:48 Integrated Voltage Measurement... 17:11:57 Voltage Offset Correction: v_off_ini = 732.822 uV, v_off_fin = 737.580 uV 17:11:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.938 uVs 17:11:57 Integrated Voltage Measurement... 17:12:06 Voltage Offset Correction: v_off_ini = 730.077 uV, v_off_fin = 716.171 uV 17:12:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.534 uVs 17:12:07 Integrated Voltage Measurement... 17:12:15 Voltage Offset Correction: v_off_ini = 730.731 uV, v_off_fin = 740.273 uV 17:12:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.615 uVs 17:12:16 Integrated Voltage Measurement... 17:12:24 Voltage Offset Correction: v_off_ini = 741.423 uV, v_off_fin = 729.541 uV 17:12:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.687 uVs 17:12:25 Integrated Voltage Measurement... 17:12:33 Voltage Offset Correction: v_off_ini = 730.250 uV, v_off_fin = 746.562 uV 17:12:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.874 uVs 17:12:38 I1Y Average and RMS of Measurements VT = -211.751 +- 1.200 uVs I1Y = -42.350 +- 0.240 uTm 17:12:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:43 Integrated Voltage Measurement... 17:12:52 Voltage Offset Correction: v_off_ini = 723.263 uV, v_off_fin = 730.626 uV 17:12:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.161 uVs 17:12:52 Integrated Voltage Measurement... 17:13:01 Voltage Offset Correction: v_off_ini = 741.456 uV, v_off_fin = 725.429 uV 17:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.868 uVs 17:13:01 Integrated Voltage Measurement... 17:13:10 Voltage Offset Correction: v_off_ini = 732.473 uV, v_off_fin = 718.058 uV 17:13:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.336 uVs 17:13:10 Integrated Voltage Measurement... 17:13:19 Voltage Offset Correction: v_off_ini = 728.590 uV, v_off_fin = 738.662 uV 17:13:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.103 uVs 17:13:19 Integrated Voltage Measurement... 17:13:28 Voltage Offset Correction: v_off_ini = 741.660 uV, v_off_fin = 736.513 uV 17:13:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.661 uVs 17:13:28 Integrated Voltage Measurement... 17:13:37 Voltage Offset Correction: v_off_ini = 749.666 uV, v_off_fin = 744.628 uV 17:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.221 uVs 17:13:39 I2X Average and RMS of Measurements VT = -118.392 +- 8.131 uVs I2X = 10.892 +- 0.748 uTm^2 17:13:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:45 Integrated Voltage Measurement... 17:13:54 Voltage Offset Correction: v_off_ini = 738.233 uV, v_off_fin = 735.889 uV 17:13:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.641 uVs 17:13:54 Integrated Voltage Measurement... 17:14:03 Voltage Offset Correction: v_off_ini = 740.190 uV, v_off_fin = 734.718 uV 17:14:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.843 uVs 17:14:03 Integrated Voltage Measurement... 17:14:12 Voltage Offset Correction: v_off_ini = 727.773 uV, v_off_fin = 722.800 uV 17:14:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.046 uVs 17:14:12 Integrated Voltage Measurement... 17:14:21 Voltage Offset Correction: v_off_ini = 736.888 uV, v_off_fin = 741.105 uV 17:14:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 453.301 uVs 17:14:21 Integrated Voltage Measurement... 17:14:30 Voltage Offset Correction: v_off_ini = 733.354 uV, v_off_fin = 727.919 uV 17:14:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.422 uVs 17:14:30 Integrated Voltage Measurement... 17:14:39 Voltage Offset Correction: v_off_ini = 728.263 uV, v_off_fin = 734.307 uV 17:14:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.656 uVs 17:14:41 I2Y Average and RMS of Measurements VT = -468.651 +- 6.694 uVs I2Y = -43.116 +- 0.616 uTm^2 17:14:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:14:50 Integrated Voltage Measurement... 17:14:59 Voltage Offset Correction: v_off_ini = 711.679 uV, v_off_fin = 716.707 uV 17:14:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -126.628 uVs 17:14:59 Integrated Voltage Measurement... 17:15:08 Voltage Offset Correction: v_off_ini = 711.419 uV, v_off_fin = 713.979 uV 17:15:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.949 uVs 17:15:08 Integrated Voltage Measurement... 17:15:17 Voltage Offset Correction: v_off_ini = 712.267 uV, v_off_fin = 705.563 uV 17:15:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.746 uVs 17:15:17 Integrated Voltage Measurement... 17:15:26 Voltage Offset Correction: v_off_ini = 708.168 uV, v_off_fin = 726.610 uV 17:15:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.821 uVs 17:15:26 Integrated Voltage Measurement... 17:15:35 Voltage Offset Correction: v_off_ini = 723.813 uV, v_off_fin = 726.065 uV 17:15:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.117 uVs 17:15:35 Integrated Voltage Measurement... 17:15:44 Voltage Offset Correction: v_off_ini = 728.444 uV, v_off_fin = 724.550 uV 17:15:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.102 uVs 17:15:48 I1X Average and RMS of Measurements VT = -131.727 +- 8.302 uVs I1X = 26.347 +- 1.660 uTm 17:15:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:15:55 Integrated Voltage Measurement... 17:16:04 Voltage Offset Correction: v_off_ini = 716.595 uV, v_off_fin = 714.770 uV 17:16:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.298 uVs 17:16:04 Integrated Voltage Measurement... 17:16:13 Voltage Offset Correction: v_off_ini = 728.117 uV, v_off_fin = 740.597 uV 17:16:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.673 uVs 17:16:13 Integrated Voltage Measurement... 17:16:22 Voltage Offset Correction: v_off_ini = 713.199 uV, v_off_fin = 707.259 uV 17:16:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.181 uVs 17:16:22 Integrated Voltage Measurement... 17:16:31 Voltage Offset Correction: v_off_ini = 714.251 uV, v_off_fin = 725.872 uV 17:16:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.395 uVs 17:16:31 Integrated Voltage Measurement... 17:16:40 Voltage Offset Correction: v_off_ini = 721.296 uV, v_off_fin = 720.979 uV 17:16:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.402 uVs 17:16:40 Integrated Voltage Measurement... 17:16:49 Voltage Offset Correction: v_off_ini = 732.070 uV, v_off_fin = 734.817 uV 17:16:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.502 uVs 17:16:53 I1Y Average and RMS of Measurements VT = -211.242 +- 3.393 uVs I1Y = -42.245 +- 0.677 uTm 17:16:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:16:58 Integrated Voltage Measurement... 17:17:07 Voltage Offset Correction: v_off_ini = 725.505 uV, v_off_fin = 727.461 uV 17:17:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.880 uVs 17:17:07 Integrated Voltage Measurement... 17:17:16 Voltage Offset Correction: v_off_ini = 734.587 uV, v_off_fin = 737.023 uV 17:17:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.820 uVs 17:17:16 Integrated Voltage Measurement... 17:17:25 Voltage Offset Correction: v_off_ini = 718.478 uV, v_off_fin = 713.380 uV 17:17:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.188 uVs 17:17:25 Integrated Voltage Measurement... 17:17:34 Voltage Offset Correction: v_off_ini = 722.786 uV, v_off_fin = 734.764 uV 17:17:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.812 uVs 17:17:34 Integrated Voltage Measurement... 17:17:43 Voltage Offset Correction: v_off_ini = 732.791 uV, v_off_fin = 718.544 uV 17:17:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.463 uVs 17:17:43 Integrated Voltage Measurement... 17:17:52 Voltage Offset Correction: v_off_ini = 733.172 uV, v_off_fin = 737.375 uV 17:17:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.098 uVs 17:17:55 I2X Average and RMS of Measurements VT = -114.210 +- 5.117 uVs I2X = 10.507 +- 0.471 uTm^2 17:17:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:18:00 Integrated Voltage Measurement... 17:18:09 Voltage Offset Correction: v_off_ini = 722.079 uV, v_off_fin = 715.905 uV 17:18:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -466.233 uVs 17:18:09 Integrated Voltage Measurement... 17:18:18 Voltage Offset Correction: v_off_ini = 720.076 uV, v_off_fin = 719.048 uV 17:18:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.315 uVs 17:18:18 Integrated Voltage Measurement... 17:18:27 Voltage Offset Correction: v_off_ini = 722.594 uV, v_off_fin = 723.685 uV 17:18:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -474.614 uVs 17:18:27 Integrated Voltage Measurement... 17:18:36 Voltage Offset Correction: v_off_ini = 734.065 uV, v_off_fin = 719.531 uV 17:18:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.661 uVs 17:18:36 Integrated Voltage Measurement... 17:18:45 Voltage Offset Correction: v_off_ini = 725.584 uV, v_off_fin = 723.167 uV 17:18:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -448.606 uVs 17:18:45 Integrated Voltage Measurement... 17:18:54 Voltage Offset Correction: v_off_ini = 731.275 uV, v_off_fin = 736.239 uV 17:18:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 464.989 uVs 17:18:57 I2Y Average and RMS of Measurements VT = -462.236 +- 5.143 uVs I2Y = -42.526 +- 0.473 uTm^2 17:19:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:19:05 Integrated Voltage Measurement... 17:19:14 Voltage Offset Correction: v_off_ini = 714.119 uV, v_off_fin = 727.584 uV 17:19:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.093 uVs 17:19:14 Integrated Voltage Measurement... 17:19:23 Voltage Offset Correction: v_off_ini = 738.421 uV, v_off_fin = 742.499 uV 17:19:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.760 uVs 17:19:23 Integrated Voltage Measurement... 17:19:32 Voltage Offset Correction: v_off_ini = 735.516 uV, v_off_fin = 741.356 uV 17:19:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.377 uVs 17:19:32 Integrated Voltage Measurement... 17:19:41 Voltage Offset Correction: v_off_ini = 748.813 uV, v_off_fin = 762.797 uV 17:19:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.370 uVs 17:19:41 Integrated Voltage Measurement... 17:19:50 Voltage Offset Correction: v_off_ini = 769.769 uV, v_off_fin = 752.559 uV 17:19:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.432 uVs 17:19:50 Integrated Voltage Measurement... 17:19:59 Voltage Offset Correction: v_off_ini = 776.179 uV, v_off_fin = 771.514 uV 17:19:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.371 uVs 17:20:03 I1X Average and RMS of Measurements VT = -126.234 +- 4.628 uVs I1X = 25.248 +- 0.926 uTm 17:20:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:20:10 Integrated Voltage Measurement... 17:20:19 Voltage Offset Correction: v_off_ini = 742.071 uV, v_off_fin = 738.910 uV 17:20:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.984 uVs 17:20:19 Integrated Voltage Measurement... 17:20:28 Voltage Offset Correction: v_off_ini = 743.375 uV, v_off_fin = 761.488 uV 17:20:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.051 uVs 17:20:28 Integrated Voltage Measurement... 17:20:37 Voltage Offset Correction: v_off_ini = 754.778 uV, v_off_fin = 738.596 uV 17:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.161 uVs 17:20:37 Integrated Voltage Measurement... 17:20:46 Voltage Offset Correction: v_off_ini = 740.884 uV, v_off_fin = 746.638 uV 17:20:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.161 uVs 17:20:46 Integrated Voltage Measurement... 17:20:55 Voltage Offset Correction: v_off_ini = 745.502 uV, v_off_fin = 741.621 uV 17:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.207 uVs 17:20:55 Integrated Voltage Measurement... 17:21:04 Voltage Offset Correction: v_off_ini = 723.705 uV, v_off_fin = 747.543 uV 17:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.916 uVs 17:21:08 I1Y Average and RMS of Measurements VT = -206.580 +- 6.230 uVs I1Y = -41.312 +- 1.246 uTm 17:21:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:21:13 Integrated Voltage Measurement... 17:21:22 Voltage Offset Correction: v_off_ini = 737.390 uV, v_off_fin = 738.782 uV 17:21:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.843 uVs 17:21:22 Integrated Voltage Measurement... 17:21:31 Voltage Offset Correction: v_off_ini = 746.572 uV, v_off_fin = 740.585 uV 17:21:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.392 uVs 17:21:31 Integrated Voltage Measurement... 17:21:40 Voltage Offset Correction: v_off_ini = 740.081 uV, v_off_fin = 734.698 uV 17:21:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.214 uVs 17:21:40 Integrated Voltage Measurement... 17:21:49 Voltage Offset Correction: v_off_ini = 740.778 uV, v_off_fin = 747.136 uV 17:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.419 uVs 17:21:49 Integrated Voltage Measurement... 17:21:58 Voltage Offset Correction: v_off_ini = 726.597 uV, v_off_fin = 717.815 uV 17:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.388 uVs 17:21:58 Integrated Voltage Measurement... 17:22:07 Voltage Offset Correction: v_off_ini = 735.483 uV, v_off_fin = 741.494 uV 17:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.115 uVs 17:22:10 I2X Average and RMS of Measurements VT = -111.062 +- 1.761 uVs I2X = 10.218 +- 0.162 uTm^2 17:22:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:22:15 Integrated Voltage Measurement... 17:22:24 Voltage Offset Correction: v_off_ini = 727.987 uV, v_off_fin = 737.059 uV 17:22:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.683 uVs 17:22:24 Integrated Voltage Measurement... 17:22:33 Voltage Offset Correction: v_off_ini = 726.256 uV, v_off_fin = 728.040 uV 17:22:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 464.152 uVs 17:22:33 Integrated Voltage Measurement... 17:22:42 Voltage Offset Correction: v_off_ini = 718.673 uV, v_off_fin = 719.071 uV 17:22:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.647 uVs 17:22:42 Integrated Voltage Measurement... 17:22:51 Voltage Offset Correction: v_off_ini = 711.175 uV, v_off_fin = 718.145 uV 17:22:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.747 uVs 17:22:51 Integrated Voltage Measurement... 17:23:00 Voltage Offset Correction: v_off_ini = 721.012 uV, v_off_fin = 713.347 uV 17:23:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.046 uVs 17:23:00 Integrated Voltage Measurement... 17:23:09 Voltage Offset Correction: v_off_ini = 716.918 uV, v_off_fin = 721.963 uV 17:23:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.275 uVs 17:23:12 I2Y Average and RMS of Measurements VT = -461.758 +- 3.464 uVs I2Y = -42.482 +- 0.319 uTm^2 17:23:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:23:33 Integrated Voltage Measurement... 17:23:42 Voltage Offset Correction: v_off_ini = 723.532 uV, v_off_fin = 708.051 uV 17:23:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -141.464 uVs 17:23:42 Integrated Voltage Measurement... 17:23:51 Voltage Offset Correction: v_off_ini = 716.514 uV, v_off_fin = 729.720 uV 17:23:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 129.331 uVs 17:23:51 Integrated Voltage Measurement... 17:24:00 Voltage Offset Correction: v_off_ini = 714.290 uV, v_off_fin = 717.368 uV 17:24:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.785 uVs 17:24:00 Integrated Voltage Measurement... 17:24:09 Voltage Offset Correction: v_off_ini = 716.566 uV, v_off_fin = 706.377 uV 17:24:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.632 uVs 17:24:09 Integrated Voltage Measurement... 17:24:18 Voltage Offset Correction: v_off_ini = 706.876 uV, v_off_fin = 711.865 uV 17:24:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.047 uVs 17:24:18 Integrated Voltage Measurement... 17:24:27 Voltage Offset Correction: v_off_ini = 708.754 uV, v_off_fin = 716.245 uV 17:24:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.807 uVs 17:24:31 I1X Average and RMS of Measurements VT = -135.011 +- 6.449 uVs I1X = 27.005 +- 1.290 uTm 17:24:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:24:38 Integrated Voltage Measurement... 17:24:47 Voltage Offset Correction: v_off_ini = 696.130 uV, v_off_fin = 693.735 uV 17:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.665 uVs 17:24:47 Integrated Voltage Measurement... 17:24:56 Voltage Offset Correction: v_off_ini = 704.028 uV, v_off_fin = 712.804 uV 17:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.312 uVs 17:24:56 Integrated Voltage Measurement... 17:25:05 Voltage Offset Correction: v_off_ini = 710.903 uV, v_off_fin = 697.662 uV 17:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.898 uVs 17:25:05 Integrated Voltage Measurement... 17:25:14 Voltage Offset Correction: v_off_ini = 694.288 uV, v_off_fin = 703.264 uV 17:25:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.131 uVs 17:25:14 Integrated Voltage Measurement... 17:25:23 Voltage Offset Correction: v_off_ini = 710.540 uV, v_off_fin = 707.214 uV 17:25:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.363 uVs 17:25:23 Integrated Voltage Measurement... 17:25:32 Voltage Offset Correction: v_off_ini = 717.920 uV, v_off_fin = 717.484 uV 17:25:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.193 uVs 17:25:36 I1Y Average and RMS of Measurements VT = -216.094 +- 2.069 uVs I1Y = -43.219 +- 0.414 uTm 17:25:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:25:44 Integrated Voltage Measurement... 17:25:53 Voltage Offset Correction: v_off_ini = 694.310 uV, v_off_fin = 691.438 uV 17:25:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.534 uVs 17:25:53 Integrated Voltage Measurement... 17:26:02 Voltage Offset Correction: v_off_ini = 704.495 uV, v_off_fin = 714.209 uV 17:26:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.194 uVs 17:26:02 Integrated Voltage Measurement... 17:26:11 Voltage Offset Correction: v_off_ini = 699.564 uV, v_off_fin = 695.486 uV 17:26:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.469 uVs 17:26:11 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = 713.166 uV, v_off_fin = 719.172 uV 17:26:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.181 uVs 17:26:20 Integrated Voltage Measurement... 17:26:29 Voltage Offset Correction: v_off_ini = 702.387 uV, v_off_fin = 713.753 uV 17:26:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.873 uVs 17:26:29 Integrated Voltage Measurement... 17:26:38 Voltage Offset Correction: v_off_ini = 709.442 uV, v_off_fin = 721.061 uV 17:26:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.523 uVs 17:26:40 I2X Average and RMS of Measurements VT = -122.296 +- 1.941 uVs I2X = 11.251 +- 0.178 uTm^2 17:26:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:26:48 Integrated Voltage Measurement... 17:26:57 Voltage Offset Correction: v_off_ini = 711.442 uV, v_off_fin = 708.988 uV 17:26:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -431.561 uVs 17:26:57 Integrated Voltage Measurement... 17:27:06 Voltage Offset Correction: v_off_ini = 717.540 uV, v_off_fin = 722.088 uV 17:27:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.565 uVs 17:27:06 Integrated Voltage Measurement... 17:27:15 Voltage Offset Correction: v_off_ini = 731.809 uV, v_off_fin = 721.294 uV 17:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.857 uVs 17:27:15 Integrated Voltage Measurement... 17:27:24 Voltage Offset Correction: v_off_ini = 716.006 uV, v_off_fin = 719.064 uV 17:27:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.633 uVs 17:27:24 Integrated Voltage Measurement... 17:27:33 Voltage Offset Correction: v_off_ini = 722.479 uV, v_off_fin = 708.112 uV 17:27:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.338 uVs 17:27:33 Integrated Voltage Measurement... 17:27:42 Voltage Offset Correction: v_off_ini = 704.688 uV, v_off_fin = 706.565 uV 17:27:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.091 uVs 17:27:44 I2Y Average and RMS of Measurements VT = -444.841 +- 8.075 uVs I2Y = -40.925 +- 0.743 uTm^2 17:27:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:27:53 Integrated Voltage Measurement... 17:28:02 Voltage Offset Correction: v_off_ini = 715.971 uV, v_off_fin = 707.889 uV 17:28:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.189 uVs 17:28:02 Integrated Voltage Measurement... 17:28:11 Voltage Offset Correction: v_off_ini = 701.586 uV, v_off_fin = 703.869 uV 17:28:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.368 uVs 17:28:11 Integrated Voltage Measurement... 17:28:20 Voltage Offset Correction: v_off_ini = 702.052 uV, v_off_fin = 712.151 uV 17:28:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.099 uVs 17:28:20 Integrated Voltage Measurement... 17:28:29 Voltage Offset Correction: v_off_ini = 705.099 uV, v_off_fin = 701.017 uV 17:28:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.719 uVs 17:28:29 Integrated Voltage Measurement... 17:28:38 Voltage Offset Correction: v_off_ini = 704.477 uV, v_off_fin = 699.866 uV 17:28:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.802 uVs 17:28:38 Integrated Voltage Measurement... 17:28:47 Voltage Offset Correction: v_off_ini = 718.837 uV, v_off_fin = 721.397 uV 17:28:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.993 uVs 17:28:52 I1X Average and RMS of Measurements VT = -138.528 +- 2.391 uVs I1X = 27.706 +- 0.478 uTm 17:28:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:28:58 Integrated Voltage Measurement... 17:29:07 Voltage Offset Correction: v_off_ini = 716.232 uV, v_off_fin = 709.830 uV 17:29:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.964 uVs 17:29:07 Integrated Voltage Measurement... 17:29:16 Voltage Offset Correction: v_off_ini = 734.699 uV, v_off_fin = 741.868 uV 17:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.494 uVs 17:29:16 Integrated Voltage Measurement... 17:29:25 Voltage Offset Correction: v_off_ini = 738.034 uV, v_off_fin = 717.084 uV 17:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.222 uVs 17:29:25 Integrated Voltage Measurement... 17:29:34 Voltage Offset Correction: v_off_ini = 731.371 uV, v_off_fin = 731.775 uV 17:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.900 uVs 17:29:34 Integrated Voltage Measurement... 17:29:43 Voltage Offset Correction: v_off_ini = 723.450 uV, v_off_fin = 718.221 uV 17:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.454 uVs 17:29:43 Integrated Voltage Measurement... 17:29:52 Voltage Offset Correction: v_off_ini = 723.142 uV, v_off_fin = 729.089 uV 17:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.806 uVs 17:29:57 I1Y Average and RMS of Measurements VT = -222.807 +- 6.559 uVs I1Y = -44.561 +- 1.312 uTm 17:30:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:30:04 Integrated Voltage Measurement... 17:30:13 Voltage Offset Correction: v_off_ini = 690.699 uV, v_off_fin = 706.353 uV 17:30:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.219 uVs 17:30:13 Integrated Voltage Measurement... 17:30:22 Voltage Offset Correction: v_off_ini = 722.795 uV, v_off_fin = 736.041 uV 17:30:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.570 uVs 17:30:22 Integrated Voltage Measurement... 17:30:31 Voltage Offset Correction: v_off_ini = 714.757 uV, v_off_fin = 703.614 uV 17:30:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.937 uVs 17:30:31 Integrated Voltage Measurement... 17:30:40 Voltage Offset Correction: v_off_ini = 717.088 uV, v_off_fin = 716.798 uV 17:30:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.857 uVs 17:30:40 Integrated Voltage Measurement... 17:30:49 Voltage Offset Correction: v_off_ini = 704.310 uV, v_off_fin = 704.653 uV 17:30:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.123 uVs 17:30:49 Integrated Voltage Measurement... 17:30:58 Voltage Offset Correction: v_off_ini = 715.447 uV, v_off_fin = 725.852 uV 17:30:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.749 uVs 17:31:01 I2X Average and RMS of Measurements VT = -122.742 +- 4.466 uVs I2X = 11.293 +- 0.411 uTm^2 17:31:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:31:08 Integrated Voltage Measurement... 17:31:17 Voltage Offset Correction: v_off_ini = 721.362 uV, v_off_fin = 723.181 uV 17:31:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -448.254 uVs 17:31:17 Integrated Voltage Measurement... 17:31:26 Voltage Offset Correction: v_off_ini = 723.351 uV, v_off_fin = 718.268 uV 17:31:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.393 uVs 17:31:26 Integrated Voltage Measurement... 17:31:35 Voltage Offset Correction: v_off_ini = 719.576 uV, v_off_fin = 717.062 uV 17:31:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.119 uVs 17:31:35 Integrated Voltage Measurement... 17:31:44 Voltage Offset Correction: v_off_ini = 699.458 uV, v_off_fin = 700.150 uV 17:31:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.077 uVs 17:31:44 Integrated Voltage Measurement... 17:31:53 Voltage Offset Correction: v_off_ini = 707.214 uV, v_off_fin = 706.660 uV 17:31:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.601 uVs 17:31:53 Integrated Voltage Measurement... 17:32:02 Voltage Offset Correction: v_off_ini = 717.774 uV, v_off_fin = 721.146 uV 17:32:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.040 uVs 17:32:05 I2Y Average and RMS of Measurements VT = -449.581 +- 4.089 uVs I2Y = -41.361 +- 0.376 uTm^2 17:32:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:32:14 Integrated Voltage Measurement... 17:32:23 Voltage Offset Correction: v_off_ini = 709.648 uV, v_off_fin = 698.300 uV 17:32:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -123.635 uVs 17:32:23 Integrated Voltage Measurement... 17:32:32 Voltage Offset Correction: v_off_ini = 707.520 uV, v_off_fin = 709.837 uV 17:32:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.524 uVs 17:32:32 Integrated Voltage Measurement... 17:32:41 Voltage Offset Correction: v_off_ini = 696.982 uV, v_off_fin = 704.564 uV 17:32:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.270 uVs 17:32:41 Integrated Voltage Measurement... 17:32:50 Voltage Offset Correction: v_off_ini = 724.227 uV, v_off_fin = 722.016 uV 17:32:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.911 uVs 17:32:50 Integrated Voltage Measurement... 17:32:59 Voltage Offset Correction: v_off_ini = 702.218 uV, v_off_fin = 705.288 uV 17:32:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.445 uVs 17:32:59 Integrated Voltage Measurement... 17:33:08 Voltage Offset Correction: v_off_ini = 721.404 uV, v_off_fin = 705.925 uV 17:33:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.136 uVs 17:33:12 I1X Average and RMS of Measurements VT = -133.654 +- 2.643 uVs I1X = 26.731 +- 0.529 uTm 17:33:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:19 Integrated Voltage Measurement... 17:33:27 Voltage Offset Correction: v_off_ini = 711.478 uV, v_off_fin = 693.914 uV 17:33:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.630 uVs 17:33:28 Integrated Voltage Measurement... 17:33:36 Voltage Offset Correction: v_off_ini = 714.712 uV, v_off_fin = 729.997 uV 17:33:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.358 uVs 17:33:36 Integrated Voltage Measurement... 17:33:45 Voltage Offset Correction: v_off_ini = 715.452 uV, v_off_fin = 692.911 uV 17:33:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.442 uVs 17:33:45 Integrated Voltage Measurement... 17:33:54 Voltage Offset Correction: v_off_ini = 707.093 uV, v_off_fin = 701.382 uV 17:33:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.134 uVs 17:33:54 Integrated Voltage Measurement... 17:34:03 Voltage Offset Correction: v_off_ini = 702.867 uV, v_off_fin = 688.841 uV 17:34:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.553 uVs 17:34:03 Integrated Voltage Measurement... 17:34:12 Voltage Offset Correction: v_off_ini = 686.974 uV, v_off_fin = 710.120 uV 17:34:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.569 uVs 17:34:17 I1Y Average and RMS of Measurements VT = -205.781 +- 3.115 uVs I1Y = -41.156 +- 0.623 uTm 17:34:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:24 Integrated Voltage Measurement... 17:34:33 Voltage Offset Correction: v_off_ini = 708.399 uV, v_off_fin = 699.425 uV 17:34:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.231 uVs 17:34:33 Integrated Voltage Measurement... 17:34:42 Voltage Offset Correction: v_off_ini = 694.864 uV, v_off_fin = 710.632 uV 17:34:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.290 uVs 17:34:42 Integrated Voltage Measurement... 17:34:51 Voltage Offset Correction: v_off_ini = 718.752 uV, v_off_fin = 700.990 uV 17:34:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.009 uVs 17:34:51 Integrated Voltage Measurement... 17:35:00 Voltage Offset Correction: v_off_ini = 691.627 uV, v_off_fin = 704.610 uV 17:35:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.407 uVs 17:35:00 Integrated Voltage Measurement... 17:35:09 Voltage Offset Correction: v_off_ini = 710.014 uV, v_off_fin = 711.332 uV 17:35:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.388 uVs 17:35:09 Integrated Voltage Measurement... 17:35:18 Voltage Offset Correction: v_off_ini = 707.918 uV, v_off_fin = 717.188 uV 17:35:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 147.392 uVs 17:35:21 I2X Average and RMS of Measurements VT = -130.286 +- 7.687 uVs I2X = 11.987 +- 0.707 uTm^2 17:35:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:28 Integrated Voltage Measurement... 17:35:37 Voltage Offset Correction: v_off_ini = 706.672 uV, v_off_fin = 716.474 uV 17:35:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.391 uVs 17:35:37 Integrated Voltage Measurement... 17:35:46 Voltage Offset Correction: v_off_ini = 716.804 uV, v_off_fin = 721.957 uV 17:35:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.819 uVs 17:35:46 Integrated Voltage Measurement... 17:35:55 Voltage Offset Correction: v_off_ini = 720.545 uV, v_off_fin = 721.554 uV 17:35:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -448.753 uVs 17:35:55 Integrated Voltage Measurement... 17:36:04 Voltage Offset Correction: v_off_ini = 728.881 uV, v_off_fin = 712.631 uV 17:36:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 453.201 uVs 17:36:05 Integrated Voltage Measurement... 17:36:14 Voltage Offset Correction: v_off_ini = 721.050 uV, v_off_fin = 722.280 uV 17:36:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -459.480 uVs 17:36:14 Integrated Voltage Measurement... 17:36:23 Voltage Offset Correction: v_off_ini = 717.087 uV, v_off_fin = 726.166 uV 17:36:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 445.303 uVs 17:36:25 I2Y Average and RMS of Measurements VT = -453.158 +- 2.163 uVs I2Y = -41.692 +- 0.198 uTm^2 17:36:30 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:36:34 Integrated Voltage Measurement... 17:36:43 Voltage Offset Correction: v_off_ini = 725.349 uV, v_off_fin = 722.978 uV 17:36:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -157.561 uVs 17:36:43 Integrated Voltage Measurement... 17:36:52 Voltage Offset Correction: v_off_ini = 735.208 uV, v_off_fin = 729.672 uV 17:36:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.289 uVs 17:36:52 Integrated Voltage Measurement... 17:37:01 Voltage Offset Correction: v_off_ini = 729.129 uV, v_off_fin = 725.999 uV 17:37:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.829 uVs 17:37:01 Integrated Voltage Measurement... 17:37:10 Voltage Offset Correction: v_off_ini = 737.786 uV, v_off_fin = 733.524 uV 17:37:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.430 uVs 17:37:10 Integrated Voltage Measurement... 17:37:19 Voltage Offset Correction: v_off_ini = 721.771 uV, v_off_fin = 724.467 uV 17:37:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -135.812 uVs 17:37:19 Integrated Voltage Measurement... 17:37:28 Voltage Offset Correction: v_off_ini = 729.959 uV, v_off_fin = 732.136 uV 17:37:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.187 uVs 17:37:32 I1X Average and RMS of Measurements VT = -144.351 +- 3.788 uVs I1X = 28.874 +- 0.758 uTm 17:37:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:37:39 Integrated Voltage Measurement... 17:37:48 Voltage Offset Correction: v_off_ini = 733.048 uV, v_off_fin = 733.037 uV 17:37:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -215.222 uVs 17:37:48 Integrated Voltage Measurement... 17:37:57 Voltage Offset Correction: v_off_ini = 749.633 uV, v_off_fin = 754.114 uV 17:37:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.019 uVs 17:37:57 Integrated Voltage Measurement... 17:38:06 Voltage Offset Correction: v_off_ini = 743.761 uV, v_off_fin = 744.071 uV 17:38:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.142 uVs 17:38:06 Integrated Voltage Measurement... 17:38:15 Voltage Offset Correction: v_off_ini = 742.909 uV, v_off_fin = 739.617 uV 17:38:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.869 uVs 17:38:15 Integrated Voltage Measurement... 17:38:24 Voltage Offset Correction: v_off_ini = 740.307 uV, v_off_fin = 732.240 uV 17:38:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.456 uVs 17:38:24 Integrated Voltage Measurement... 17:38:33 Voltage Offset Correction: v_off_ini = 738.492 uV, v_off_fin = 746.321 uV 17:38:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.405 uVs 17:38:37 I1Y Average and RMS of Measurements VT = -219.519 +- 4.638 uVs I1Y = -43.905 +- 0.927 uTm 17:38:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:38:45 Integrated Voltage Measurement... 17:38:54 Voltage Offset Correction: v_off_ini = 742.007 uV, v_off_fin = 726.236 uV 17:38:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.286 uVs 17:38:54 Integrated Voltage Measurement... 17:39:03 Voltage Offset Correction: v_off_ini = 748.844 uV, v_off_fin = 745.435 uV 17:39:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.392 uVs 17:39:03 Integrated Voltage Measurement... 17:39:12 Voltage Offset Correction: v_off_ini = 726.362 uV, v_off_fin = 729.020 uV 17:39:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.169 uVs 17:39:12 Integrated Voltage Measurement... 17:39:21 Voltage Offset Correction: v_off_ini = 740.113 uV, v_off_fin = 731.301 uV 17:39:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.228 uVs 17:39:21 Integrated Voltage Measurement... 17:39:30 Voltage Offset Correction: v_off_ini = 737.318 uV, v_off_fin = 730.992 uV 17:39:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.964 uVs 17:39:30 Integrated Voltage Measurement... 17:39:39 Voltage Offset Correction: v_off_ini = 730.760 uV, v_off_fin = 747.523 uV 17:39:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.488 uVs 17:39:41 I2X Average and RMS of Measurements VT = -121.255 +- 9.192 uVs I2X = 11.155 +- 0.846 uTm^2 17:39:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:39:49 Integrated Voltage Measurement... 17:39:58 Voltage Offset Correction: v_off_ini = 744.465 uV, v_off_fin = 750.528 uV 17:39:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.875 uVs 17:39:58 Integrated Voltage Measurement... 17:40:07 Voltage Offset Correction: v_off_ini = 736.826 uV, v_off_fin = 744.583 uV 17:40:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.479 uVs 17:40:07 Integrated Voltage Measurement... 17:40:16 Voltage Offset Correction: v_off_ini = 736.975 uV, v_off_fin = 723.689 uV 17:40:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.457 uVs 17:40:16 Integrated Voltage Measurement... 17:40:25 Voltage Offset Correction: v_off_ini = 739.427 uV, v_off_fin = 735.425 uV 17:40:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.076 uVs 17:40:25 Integrated Voltage Measurement... 17:40:34 Voltage Offset Correction: v_off_ini = 736.844 uV, v_off_fin = 721.723 uV 17:40:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.561 uVs 17:40:34 Integrated Voltage Measurement... 17:40:43 Voltage Offset Correction: v_off_ini = 723.281 uV, v_off_fin = 706.881 uV 17:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.992 uVs 17:40:46 I2Y Average and RMS of Measurements VT = -452.907 +- 7.048 uVs I2Y = -41.667 +- 0.648 uTm^2 17:40:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:40:54 Integrated Voltage Measurement... 17:41:03 Voltage Offset Correction: v_off_ini = 726.480 uV, v_off_fin = 714.973 uV 17:41:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -167.938 uVs 17:41:03 Integrated Voltage Measurement... 17:41:12 Voltage Offset Correction: v_off_ini = 722.592 uV, v_off_fin = 719.323 uV 17:41:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.334 uVs 17:41:13 Integrated Voltage Measurement... 17:41:21 Voltage Offset Correction: v_off_ini = 719.207 uV, v_off_fin = 712.049 uV 17:41:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.275 uVs 17:41:22 Integrated Voltage Measurement... 17:41:30 Voltage Offset Correction: v_off_ini = 714.149 uV, v_off_fin = 711.224 uV 17:41:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.623 uVs 17:41:31 Integrated Voltage Measurement... 17:41:39 Voltage Offset Correction: v_off_ini = 729.065 uV, v_off_fin = 723.469 uV 17:41:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.261 uVs 17:41:40 Integrated Voltage Measurement... 17:41:48 Voltage Offset Correction: v_off_ini = 721.674 uV, v_off_fin = 716.786 uV 17:41:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.020 uVs 17:41:53 I1X Average and RMS of Measurements VT = -146.908 +- 10.754 uVs I1X = 29.383 +- 2.153 uTm 17:41:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:41:59 Integrated Voltage Measurement... 17:42:08 Voltage Offset Correction: v_off_ini = 725.789 uV, v_off_fin = 723.371 uV 17:42:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.460 uVs 17:42:08 Integrated Voltage Measurement... 17:42:17 Voltage Offset Correction: v_off_ini = 730.914 uV, v_off_fin = 743.359 uV 17:42:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.644 uVs 17:42:17 Integrated Voltage Measurement... 17:42:26 Voltage Offset Correction: v_off_ini = 724.897 uV, v_off_fin = 725.148 uV 17:42:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.255 uVs 17:42:26 Integrated Voltage Measurement... 17:42:35 Voltage Offset Correction: v_off_ini = 729.429 uV, v_off_fin = 738.422 uV 17:42:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.781 uVs 17:42:35 Integrated Voltage Measurement... 17:42:44 Voltage Offset Correction: v_off_ini = 728.263 uV, v_off_fin = 706.834 uV 17:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.387 uVs 17:42:44 Integrated Voltage Measurement... 17:42:53 Voltage Offset Correction: v_off_ini = 721.274 uV, v_off_fin = 721.037 uV 17:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.930 uVs 17:42:58 I1Y Average and RMS of Measurements VT = -212.243 +- 4.563 uVs I1Y = -42.449 +- 0.913 uTm 17:43:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:43:05 Integrated Voltage Measurement... 17:43:14 Voltage Offset Correction: v_off_ini = 719.724 uV, v_off_fin = 710.263 uV 17:43:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.687 uVs 17:43:14 Integrated Voltage Measurement... 17:43:23 Voltage Offset Correction: v_off_ini = 719.484 uV, v_off_fin = 721.136 uV 17:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.616 uVs 17:43:23 Integrated Voltage Measurement... 17:43:32 Voltage Offset Correction: v_off_ini = 714.449 uV, v_off_fin = 715.196 uV 17:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.498 uVs 17:43:32 Integrated Voltage Measurement... 17:43:41 Voltage Offset Correction: v_off_ini = 725.122 uV, v_off_fin = 728.843 uV 17:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.526 uVs 17:43:41 Integrated Voltage Measurement... 17:43:50 Voltage Offset Correction: v_off_ini = 725.887 uV, v_off_fin = 725.585 uV 17:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.364 uVs 17:43:50 Integrated Voltage Measurement... 17:43:59 Voltage Offset Correction: v_off_ini = 733.030 uV, v_off_fin = 727.371 uV 17:43:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.479 uVs 17:44:02 I2X Average and RMS of Measurements VT = -130.361 +- 5.235 uVs I2X = 11.993 +- 0.482 uTm^2 17:44:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:44:09 Integrated Voltage Measurement... 17:44:18 Voltage Offset Correction: v_off_ini = 724.043 uV, v_off_fin = 722.661 uV 17:44:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -459.904 uVs 17:44:19 Integrated Voltage Measurement... 17:44:28 Voltage Offset Correction: v_off_ini = 715.576 uV, v_off_fin = 718.517 uV 17:44:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 453.768 uVs 17:44:28 Integrated Voltage Measurement... 17:44:37 Voltage Offset Correction: v_off_ini = 742.442 uV, v_off_fin = 732.269 uV 17:44:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.106 uVs 17:44:37 Integrated Voltage Measurement... 17:44:46 Voltage Offset Correction: v_off_ini = 723.376 uV, v_off_fin = 724.829 uV 17:44:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.678 uVs 17:44:46 Integrated Voltage Measurement... 17:44:55 Voltage Offset Correction: v_off_ini = 706.170 uV, v_off_fin = 720.595 uV 17:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -443.170 uVs 17:44:55 Integrated Voltage Measurement... 17:45:04 Voltage Offset Correction: v_off_ini = 719.120 uV, v_off_fin = 723.047 uV 17:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.620 uVs 17:45:06 I2Y Average and RMS of Measurements VT = -451.541 +- 4.264 uVs I2Y = -41.542 +- 0.392 uTm^2 17:45:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:45:18 Integrated Voltage Measurement... 17:45:27 Voltage Offset Correction: v_off_ini = 718.098 uV, v_off_fin = 714.374 uV 17:45:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -136.683 uVs 17:45:27 Integrated Voltage Measurement... 17:45:36 Voltage Offset Correction: v_off_ini = 725.273 uV, v_off_fin = 726.652 uV 17:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.506 uVs 17:45:36 Integrated Voltage Measurement... 17:45:45 Voltage Offset Correction: v_off_ini = 733.760 uV, v_off_fin = 714.356 uV 17:45:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.195 uVs 17:45:45 Integrated Voltage Measurement... 17:45:54 Voltage Offset Correction: v_off_ini = 726.468 uV, v_off_fin = 719.091 uV 17:45:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.229 uVs 17:45:54 Integrated Voltage Measurement... 17:46:03 Voltage Offset Correction: v_off_ini = 723.169 uV, v_off_fin = 724.298 uV 17:46:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.099 uVs 17:46:03 Integrated Voltage Measurement... 17:46:12 Voltage Offset Correction: v_off_ini = 723.376 uV, v_off_fin = 726.772 uV 17:46:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.868 uVs 17:46:16 I1X Average and RMS of Measurements VT = -132.763 +- 2.971 uVs I1X = 26.554 +- 0.594 uTm 17:46:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:46:23 Integrated Voltage Measurement... 17:46:32 Voltage Offset Correction: v_off_ini = 738.853 uV, v_off_fin = 730.941 uV 17:46:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.687 uVs 17:46:32 Integrated Voltage Measurement... 17:46:41 Voltage Offset Correction: v_off_ini = 736.354 uV, v_off_fin = 734.505 uV 17:46:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.606 uVs 17:46:41 Integrated Voltage Measurement... 17:46:50 Voltage Offset Correction: v_off_ini = 727.217 uV, v_off_fin = 716.761 uV 17:46:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.164 uVs 17:46:50 Integrated Voltage Measurement... 17:46:59 Voltage Offset Correction: v_off_ini = 718.674 uV, v_off_fin = 729.192 uV 17:46:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.647 uVs 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 718.443 uV, v_off_fin = 711.757 uV 17:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.990 uVs 17:47:08 Integrated Voltage Measurement... 17:47:17 Voltage Offset Correction: v_off_ini = 716.011 uV, v_off_fin = 721.895 uV 17:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.590 uVs 17:47:21 I1Y Average and RMS of Measurements VT = -208.114 +- 2.929 uVs I1Y = -41.623 +- 0.586 uTm 17:47:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:47:26 Integrated Voltage Measurement... 17:47:35 Voltage Offset Correction: v_off_ini = 711.899 uV, v_off_fin = 704.102 uV 17:47:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.353 uVs 17:47:35 Integrated Voltage Measurement... 17:47:44 Voltage Offset Correction: v_off_ini = 697.772 uV, v_off_fin = 712.933 uV 17:47:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.844 uVs 17:47:44 Integrated Voltage Measurement... 17:47:53 Voltage Offset Correction: v_off_ini = 704.405 uV, v_off_fin = 701.207 uV 17:47:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.772 uVs 17:47:53 Integrated Voltage Measurement... 17:48:02 Voltage Offset Correction: v_off_ini = 691.635 uV, v_off_fin = 695.963 uV 17:48:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.206 uVs 17:48:02 Integrated Voltage Measurement... 17:48:11 Voltage Offset Correction: v_off_ini = 695.222 uV, v_off_fin = 688.505 uV 17:48:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.974 uVs 17:48:11 Integrated Voltage Measurement... 17:48:20 Voltage Offset Correction: v_off_ini = 695.536 uV, v_off_fin = 713.046 uV 17:48:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.990 uVs 17:48:23 I2X Average and RMS of Measurements VT = -121.190 +- 5.052 uVs I2X = 11.149 +- 0.465 uTm^2 17:48:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:48:28 Integrated Voltage Measurement... 17:48:37 Voltage Offset Correction: v_off_ini = 705.091 uV, v_off_fin = 685.957 uV 17:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.796 uVs 17:48:37 Integrated Voltage Measurement... 17:48:46 Voltage Offset Correction: v_off_ini = 686.342 uV, v_off_fin = 682.124 uV 17:48:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.763 uVs 17:48:46 Integrated Voltage Measurement... 17:48:55 Voltage Offset Correction: v_off_ini = 679.489 uV, v_off_fin = 674.135 uV 17:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -448.239 uVs 17:48:55 Integrated Voltage Measurement... 17:49:04 Voltage Offset Correction: v_off_ini = 686.074 uV, v_off_fin = 688.986 uV 17:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.270 uVs 17:49:04 Integrated Voltage Measurement... 17:49:13 Voltage Offset Correction: v_off_ini = 684.756 uV, v_off_fin = 684.241 uV 17:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.160 uVs 17:49:13 Integrated Voltage Measurement... 17:49:22 Voltage Offset Correction: v_off_ini = 683.775 uV, v_off_fin = 693.002 uV 17:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 434.413 uVs 17:49:24 I2Y Average and RMS of Measurements VT = -442.607 +- 5.714 uVs I2Y = -40.720 +- 0.526 uTm^2 17:49:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:49:33 Integrated Voltage Measurement... 17:49:42 Voltage Offset Correction: v_off_ini = 685.978 uV, v_off_fin = 685.028 uV 17:49:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.844 uVs 17:49:42 Integrated Voltage Measurement... 17:49:51 Voltage Offset Correction: v_off_ini = 669.868 uV, v_off_fin = 681.722 uV 17:49:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.597 uVs 17:49:51 Integrated Voltage Measurement... 17:50:00 Voltage Offset Correction: v_off_ini = 679.896 uV, v_off_fin = 681.296 uV 17:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.079 uVs 17:50:00 Integrated Voltage Measurement... 17:50:09 Voltage Offset Correction: v_off_ini = 685.104 uV, v_off_fin = 694.278 uV 17:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 122.197 uVs 17:50:09 Integrated Voltage Measurement... 17:50:18 Voltage Offset Correction: v_off_ini = 693.986 uV, v_off_fin = 691.750 uV 17:50:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.235 uVs 17:50:18 Integrated Voltage Measurement... 17:50:27 Voltage Offset Correction: v_off_ini = 686.241 uV, v_off_fin = 702.146 uV 17:50:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.876 uVs 17:50:31 I1X Average and RMS of Measurements VT = -124.805 +- 4.654 uVs I1X = 24.962 +- 0.930 uTm 17:50:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:50:38 Integrated Voltage Measurement... 17:50:47 Voltage Offset Correction: v_off_ini = 690.911 uV, v_off_fin = 682.589 uV 17:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.726 uVs 17:50:47 Integrated Voltage Measurement... 17:50:56 Voltage Offset Correction: v_off_ini = 692.565 uV, v_off_fin = 690.561 uV 17:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.998 uVs 17:50:56 Integrated Voltage Measurement... 17:51:05 Voltage Offset Correction: v_off_ini = 687.599 uV, v_off_fin = 685.666 uV 17:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.876 uVs 17:51:05 Integrated Voltage Measurement... 17:51:14 Voltage Offset Correction: v_off_ini = 701.823 uV, v_off_fin = 708.351 uV 17:51:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.100 uVs 17:51:14 Integrated Voltage Measurement... 17:51:23 Voltage Offset Correction: v_off_ini = 703.909 uV, v_off_fin = 695.558 uV 17:51:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.568 uVs 17:51:23 Integrated Voltage Measurement... 17:51:32 Voltage Offset Correction: v_off_ini = 712.535 uV, v_off_fin = 712.629 uV 17:51:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.902 uVs 17:51:36 I1Y Average and RMS of Measurements VT = -208.028 +- 4.264 uVs I1Y = -41.607 +- 0.855 uTm 17:51:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:51:41 Integrated Voltage Measurement... 17:51:50 Voltage Offset Correction: v_off_ini = 704.545 uV, v_off_fin = 694.222 uV 17:51:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.320 uVs 17:51:50 Integrated Voltage Measurement... 17:51:59 Voltage Offset Correction: v_off_ini = 718.843 uV, v_off_fin = 724.168 uV 17:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.701 uVs 17:51:59 Integrated Voltage Measurement... 17:52:08 Voltage Offset Correction: v_off_ini = 708.048 uV, v_off_fin = 705.670 uV 17:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.161 uVs 17:52:08 Integrated Voltage Measurement... 17:52:17 Voltage Offset Correction: v_off_ini = 714.771 uV, v_off_fin = 716.845 uV 17:52:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.214 uVs 17:52:17 Integrated Voltage Measurement... 17:52:26 Voltage Offset Correction: v_off_ini = 696.842 uV, v_off_fin = 695.067 uV 17:52:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.694 uVs 17:52:26 Integrated Voltage Measurement... 17:52:35 Voltage Offset Correction: v_off_ini = 703.611 uV, v_off_fin = 717.752 uV 17:52:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.849 uVs 17:52:38 I2X Average and RMS of Measurements VT = -116.656 +- 4.029 uVs I2X = 10.732 +- 0.371 uTm^2 17:52:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:52:43 Integrated Voltage Measurement... 17:52:52 Voltage Offset Correction: v_off_ini = 707.649 uV, v_off_fin = 714.714 uV 17:52:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -454.517 uVs 17:52:52 Integrated Voltage Measurement... 17:53:01 Voltage Offset Correction: v_off_ini = 706.633 uV, v_off_fin = 712.538 uV 17:53:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.499 uVs 17:53:01 Integrated Voltage Measurement... 17:53:10 Voltage Offset Correction: v_off_ini = 713.394 uV, v_off_fin = 713.970 uV 17:53:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.362 uVs 17:53:10 Integrated Voltage Measurement... 17:53:19 Voltage Offset Correction: v_off_ini = 703.228 uV, v_off_fin = 727.335 uV 17:53:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 457.746 uVs 17:53:19 Integrated Voltage Measurement... 17:53:28 Voltage Offset Correction: v_off_ini = 718.811 uV, v_off_fin = 716.322 uV 17:53:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -441.589 uVs 17:53:28 Integrated Voltage Measurement... 17:53:37 Voltage Offset Correction: v_off_ini = 715.480 uV, v_off_fin = 724.692 uV 17:53:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.428 uVs 17:53:39 I2Y Average and RMS of Measurements VT = -451.857 +- 7.197 uVs I2Y = -41.571 +- 0.662 uTm^2 17:53:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:53:48 Integrated Voltage Measurement... 17:53:57 Voltage Offset Correction: v_off_ini = 736.872 uV, v_off_fin = 725.525 uV 17:53:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -155.977 uVs 17:53:57 Integrated Voltage Measurement... 17:54:06 Voltage Offset Correction: v_off_ini = 733.172 uV, v_off_fin = 735.311 uV 17:54:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.097 uVs 17:54:06 Integrated Voltage Measurement... 17:54:15 Voltage Offset Correction: v_off_ini = 730.607 uV, v_off_fin = 728.968 uV 17:54:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.391 uVs 17:54:15 Integrated Voltage Measurement... 17:54:24 Voltage Offset Correction: v_off_ini = 730.197 uV, v_off_fin = 720.796 uV 17:54:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.575 uVs 17:54:24 Integrated Voltage Measurement... 17:54:33 Voltage Offset Correction: v_off_ini = 720.372 uV, v_off_fin = 720.324 uV 17:54:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.442 uVs 17:54:33 Integrated Voltage Measurement... 17:54:42 Voltage Offset Correction: v_off_ini = 724.591 uV, v_off_fin = 717.462 uV 17:54:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.850 uVs 17:54:46 I1X Average and RMS of Measurements VT = -149.055 +- 9.123 uVs I1X = 29.812 +- 1.825 uTm 17:54:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:54:53 Integrated Voltage Measurement... 17:55:02 Voltage Offset Correction: v_off_ini = 731.741 uV, v_off_fin = 719.092 uV 17:55:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.528 uVs 17:55:02 Integrated Voltage Measurement... 17:55:11 Voltage Offset Correction: v_off_ini = 729.150 uV, v_off_fin = 733.873 uV 17:55:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.117 uVs 17:55:11 Integrated Voltage Measurement... 17:55:20 Voltage Offset Correction: v_off_ini = 727.448 uV, v_off_fin = 725.322 uV 17:55:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.138 uVs 17:55:20 Integrated Voltage Measurement... 17:55:29 Voltage Offset Correction: v_off_ini = 730.447 uV, v_off_fin = 740.327 uV 17:55:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.491 uVs 17:55:29 Integrated Voltage Measurement... 17:55:38 Voltage Offset Correction: v_off_ini = 728.410 uV, v_off_fin = 721.275 uV 17:55:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.145 uVs 17:55:38 Integrated Voltage Measurement... 17:55:47 Voltage Offset Correction: v_off_ini = 725.012 uV, v_off_fin = 724.586 uV 17:55:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.090 uVs 17:55:51 I1Y Average and RMS of Measurements VT = -214.085 +- 2.108 uVs I1Y = -42.818 +- 0.421 uTm 17:55:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:55:56 Integrated Voltage Measurement... 17:56:05 Voltage Offset Correction: v_off_ini = 715.343 uV, v_off_fin = 718.534 uV 17:56:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.203 uVs 17:56:05 Integrated Voltage Measurement... 17:56:14 Voltage Offset Correction: v_off_ini = 721.111 uV, v_off_fin = 728.331 uV 17:56:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.117 uVs 17:56:14 Integrated Voltage Measurement... 17:56:23 Voltage Offset Correction: v_off_ini = 739.679 uV, v_off_fin = 728.242 uV 17:56:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.231 uVs 17:56:23 Integrated Voltage Measurement... 17:56:32 Voltage Offset Correction: v_off_ini = 743.858 uV, v_off_fin = 745.264 uV 17:56:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.448 uVs 17:56:32 Integrated Voltage Measurement... 17:56:41 Voltage Offset Correction: v_off_ini = 722.864 uV, v_off_fin = 728.783 uV 17:56:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.423 uVs 17:56:41 Integrated Voltage Measurement... 17:56:50 Voltage Offset Correction: v_off_ini = 736.126 uV, v_off_fin = 737.417 uV 17:56:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.785 uVs 17:56:53 I2X Average and RMS of Measurements VT = -126.868 +- 3.385 uVs I2X = 11.672 +- 0.312 uTm^2 17:56:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:56:58 Integrated Voltage Measurement... 17:57:07 Voltage Offset Correction: v_off_ini = 737.776 uV, v_off_fin = 739.509 uV 17:57:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -455.062 uVs 17:57:07 Integrated Voltage Measurement... 17:57:16 Voltage Offset Correction: v_off_ini = 747.218 uV, v_off_fin = 743.617 uV 17:57:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.459 uVs 17:57:16 Integrated Voltage Measurement... 17:57:25 Voltage Offset Correction: v_off_ini = 736.157 uV, v_off_fin = 732.152 uV 17:57:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.345 uVs 17:57:25 Integrated Voltage Measurement... 17:57:34 Voltage Offset Correction: v_off_ini = 726.100 uV, v_off_fin = 731.416 uV 17:57:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 469.141 uVs 17:57:34 Integrated Voltage Measurement... 17:57:43 Voltage Offset Correction: v_off_ini = 745.065 uV, v_off_fin = 728.782 uV 17:57:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.603 uVs 17:57:43 Integrated Voltage Measurement... 17:57:52 Voltage Offset Correction: v_off_ini = 734.719 uV, v_off_fin = 729.992 uV 17:57:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.658 uVs 17:57:54 I2Y Average and RMS of Measurements VT = -453.045 +- 4.737 uVs I2Y = -41.680 +- 0.436 uTm^2 17:57:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:58:02 Integrated Voltage Measurement... 17:58:11 Voltage Offset Correction: v_off_ini = 727.829 uV, v_off_fin = 741.040 uV 17:58:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.548 uVs 17:58:11 Integrated Voltage Measurement... 17:58:20 Voltage Offset Correction: v_off_ini = 746.739 uV, v_off_fin = 732.596 uV 17:58:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.266 uVs 17:58:21 Integrated Voltage Measurement... 17:58:29 Voltage Offset Correction: v_off_ini = 731.396 uV, v_off_fin = 732.949 uV 17:58:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.356 uVs 17:58:30 Integrated Voltage Measurement... 17:58:38 Voltage Offset Correction: v_off_ini = 738.669 uV, v_off_fin = 739.146 uV 17:58:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.265 uVs 17:58:39 Integrated Voltage Measurement... 17:58:48 Voltage Offset Correction: v_off_ini = 731.257 uV, v_off_fin = 730.007 uV 17:58:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.679 uVs 17:58:48 Integrated Voltage Measurement... 17:58:57 Voltage Offset Correction: v_off_ini = 733.731 uV, v_off_fin = 743.314 uV 17:58:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 130.778 uVs 17:59:01 I1X Average and RMS of Measurements VT = -132.649 +- 9.369 uVs I1X = 26.531 +- 1.874 uTm 17:59:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:59:08 Integrated Voltage Measurement... 17:59:16 Voltage Offset Correction: v_off_ini = 736.581 uV, v_off_fin = 734.372 uV 17:59:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.046 uVs 17:59:16 Integrated Voltage Measurement... 17:59:25 Voltage Offset Correction: v_off_ini = 746.431 uV, v_off_fin = 769.246 uV 17:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.487 uVs 17:59:25 Integrated Voltage Measurement... 17:59:34 Voltage Offset Correction: v_off_ini = 742.663 uV, v_off_fin = 731.410 uV 17:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.115 uVs 17:59:34 Integrated Voltage Measurement... 17:59:43 Voltage Offset Correction: v_off_ini = 744.221 uV, v_off_fin = 757.920 uV 17:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.362 uVs 17:59:43 Integrated Voltage Measurement... 17:59:52 Voltage Offset Correction: v_off_ini = 742.027 uV, v_off_fin = 732.223 uV 17:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.784 uVs 17:59:52 Integrated Voltage Measurement... 18:00:01 Voltage Offset Correction: v_off_ini = 741.600 uV, v_off_fin = 761.320 uV 18:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.324 uVs 18:00:06 I1Y Average and RMS of Measurements VT = -210.686 +- 3.613 uVs I1Y = -42.134 +- 0.722 uTm 18:00:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:00:11 Integrated Voltage Measurement... 18:00:20 Voltage Offset Correction: v_off_ini = 759.463 uV, v_off_fin = 749.079 uV 18:00:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.111 uVs 18:00:20 Integrated Voltage Measurement... 18:00:29 Voltage Offset Correction: v_off_ini = 760.106 uV, v_off_fin = 749.491 uV 18:00:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.247 uVs 18:00:29 Integrated Voltage Measurement... 18:00:38 Voltage Offset Correction: v_off_ini = 749.441 uV, v_off_fin = 736.417 uV 18:00:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.665 uVs 18:00:38 Integrated Voltage Measurement... 18:00:47 Voltage Offset Correction: v_off_ini = 751.670 uV, v_off_fin = 757.436 uV 18:00:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.432 uVs 18:00:47 Integrated Voltage Measurement... 18:00:56 Voltage Offset Correction: v_off_ini = 748.666 uV, v_off_fin = 727.292 uV 18:00:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.731 uVs 18:00:56 Integrated Voltage Measurement... 18:01:05 Voltage Offset Correction: v_off_ini = 753.701 uV, v_off_fin = 755.611 uV 18:01:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.002 uVs 18:01:07 I2X Average and RMS of Measurements VT = -129.198 +- 1.095 uVs I2X = 11.886 +- 0.101 uTm^2 18:01:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:01:12 Integrated Voltage Measurement... 18:01:21 Voltage Offset Correction: v_off_ini = 757.860 uV, v_off_fin = 755.460 uV 18:01:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.665 uVs 18:01:21 Integrated Voltage Measurement... 18:01:30 Voltage Offset Correction: v_off_ini = 759.918 uV, v_off_fin = 758.916 uV 18:01:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.583 uVs 18:01:30 Integrated Voltage Measurement... 18:01:39 Voltage Offset Correction: v_off_ini = 753.778 uV, v_off_fin = 742.346 uV 18:01:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.979 uVs 18:01:39 Integrated Voltage Measurement... 18:01:48 Voltage Offset Correction: v_off_ini = 745.064 uV, v_off_fin = 748.893 uV 18:01:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 426.964 uVs 18:01:49 Integrated Voltage Measurement... 18:01:57 Voltage Offset Correction: v_off_ini = 751.392 uV, v_off_fin = 743.922 uV 18:01:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -453.206 uVs 18:01:58 Integrated Voltage Measurement... 18:02:07 Voltage Offset Correction: v_off_ini = 751.148 uV, v_off_fin = 745.008 uV 18:02:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.167 uVs 18:02:09 I2Y Average and RMS of Measurements VT = -446.261 +- 8.559 uVs I2Y = -41.056 +- 0.787 uTm^2 18:02:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:02:17 Integrated Voltage Measurement... 18:02:26 Voltage Offset Correction: v_off_ini = 750.811 uV, v_off_fin = 735.515 uV 18:02:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -131.467 uVs 18:02:26 Integrated Voltage Measurement... 18:02:35 Voltage Offset Correction: v_off_ini = 750.522 uV, v_off_fin = 745.129 uV 18:02:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.420 uVs 18:02:35 Integrated Voltage Measurement... 18:02:44 Voltage Offset Correction: v_off_ini = 736.454 uV, v_off_fin = 733.369 uV 18:02:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.050 uVs 18:02:44 Integrated Voltage Measurement... 18:02:53 Voltage Offset Correction: v_off_ini = 748.087 uV, v_off_fin = 747.078 uV 18:02:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.959 uVs 18:02:53 Integrated Voltage Measurement... 18:03:02 Voltage Offset Correction: v_off_ini = 757.299 uV, v_off_fin = 752.093 uV 18:03:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.572 uVs 18:03:02 Integrated Voltage Measurement... 18:03:11 Voltage Offset Correction: v_off_ini = 752.679 uV, v_off_fin = 754.199 uV 18:03:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.518 uVs 18:03:16 I1X Average and RMS of Measurements VT = -130.165 +- 3.270 uVs I1X = 26.034 +- 0.655 uTm 18:03:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:03:22 Integrated Voltage Measurement... 18:03:31 Voltage Offset Correction: v_off_ini = 746.182 uV, v_off_fin = 728.151 uV 18:03:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.912 uVs 18:03:31 Integrated Voltage Measurement... 18:03:40 Voltage Offset Correction: v_off_ini = 749.174 uV, v_off_fin = 757.722 uV 18:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.422 uVs 18:03:40 Integrated Voltage Measurement... 18:03:49 Voltage Offset Correction: v_off_ini = 743.077 uV, v_off_fin = 741.785 uV 18:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.547 uVs 18:03:49 Integrated Voltage Measurement... 18:03:58 Voltage Offset Correction: v_off_ini = 731.616 uV, v_off_fin = 768.632 uV 18:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.848 uVs 18:03:58 Integrated Voltage Measurement... 18:04:07 Voltage Offset Correction: v_off_ini = 758.060 uV, v_off_fin = 737.113 uV 18:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.487 uVs 18:04:07 Integrated Voltage Measurement... 18:04:16 Voltage Offset Correction: v_off_ini = 746.817 uV, v_off_fin = 751.257 uV 18:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.293 uVs 18:04:20 I1Y Average and RMS of Measurements VT = -209.085 +- 5.581 uVs I1Y = -41.816 +- 1.117 uTm 18:04:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:04:26 Integrated Voltage Measurement... 18:04:35 Voltage Offset Correction: v_off_ini = 757.869 uV, v_off_fin = 746.620 uV 18:04:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.209 uVs 18:04:35 Integrated Voltage Measurement... 18:04:44 Voltage Offset Correction: v_off_ini = 756.090 uV, v_off_fin = 760.733 uV 18:04:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.572 uVs 18:04:44 Integrated Voltage Measurement... 18:04:53 Voltage Offset Correction: v_off_ini = 750.459 uV, v_off_fin = 740.694 uV 18:04:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -126.216 uVs 18:04:53 Integrated Voltage Measurement... 18:05:02 Voltage Offset Correction: v_off_ini = 745.006 uV, v_off_fin = 752.689 uV 18:05:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.669 uVs 18:05:02 Integrated Voltage Measurement... 18:05:11 Voltage Offset Correction: v_off_ini = 736.340 uV, v_off_fin = 722.787 uV 18:05:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.518 uVs 18:05:11 Integrated Voltage Measurement... 18:05:20 Voltage Offset Correction: v_off_ini = 725.375 uV, v_off_fin = 739.022 uV 18:05:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.264 uVs 18:05:22 I2X Average and RMS of Measurements VT = -116.575 +- 2.416 uVs I2X = 10.725 +- 0.223 uTm^2 18:05:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:05:27 Integrated Voltage Measurement... 18:05:36 Voltage Offset Correction: v_off_ini = 733.704 uV, v_off_fin = 738.751 uV 18:05:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.669 uVs 18:05:36 Integrated Voltage Measurement... 18:05:45 Voltage Offset Correction: v_off_ini = 731.223 uV, v_off_fin = 731.682 uV 18:05:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.285 uVs 18:05:45 Integrated Voltage Measurement... 18:05:54 Voltage Offset Correction: v_off_ini = 730.212 uV, v_off_fin = 734.941 uV 18:05:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -453.346 uVs 18:05:54 Integrated Voltage Measurement... 18:06:03 Voltage Offset Correction: v_off_ini = 745.308 uV, v_off_fin = 738.462 uV 18:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.735 uVs 18:06:03 Integrated Voltage Measurement... 18:06:12 Voltage Offset Correction: v_off_ini = 723.411 uV, v_off_fin = 732.921 uV 18:06:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.900 uVs 18:06:12 Integrated Voltage Measurement... 18:06:21 Voltage Offset Correction: v_off_ini = 717.892 uV, v_off_fin = 724.228 uV 18:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.825 uVs 18:06:24 I2Y Average and RMS of Measurements VT = -454.127 +- 4.661 uVs I2Y = -41.780 +- 0.429 uTm^2 18:06:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:06:59 Integrated Voltage Measurement... 18:07:08 Voltage Offset Correction: v_off_ini = 722.773 uV, v_off_fin = 723.740 uV 18:07:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.689 uVs 18:07:08 Integrated Voltage Measurement... 18:07:17 Voltage Offset Correction: v_off_ini = 746.049 uV, v_off_fin = 738.726 uV 18:07:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.870 uVs 18:07:17 Integrated Voltage Measurement... 18:07:26 Voltage Offset Correction: v_off_ini = 739.903 uV, v_off_fin = 729.929 uV 18:07:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.150 uVs 18:07:26 Integrated Voltage Measurement... 18:07:35 Voltage Offset Correction: v_off_ini = 743.954 uV, v_off_fin = 748.844 uV 18:07:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.343 uVs 18:07:35 Integrated Voltage Measurement... 18:07:44 Voltage Offset Correction: v_off_ini = 749.298 uV, v_off_fin = 747.383 uV 18:07:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.698 uVs 18:07:44 Integrated Voltage Measurement... 18:07:53 Voltage Offset Correction: v_off_ini = 729.391 uV, v_off_fin = 735.614 uV 18:07:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.892 uVs 18:07:58 I1X Average and RMS of Measurements VT = -101.774 +- 10.595 uVs I1X = 20.355 +- 2.119 uTm 18:08:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:08:04 Integrated Voltage Measurement... 18:08:13 Voltage Offset Correction: v_off_ini = 756.234 uV, v_off_fin = 736.815 uV 18:08:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.586 uVs 18:08:13 Integrated Voltage Measurement... 18:08:22 Voltage Offset Correction: v_off_ini = 740.524 uV, v_off_fin = 749.877 uV 18:08:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.843 uVs 18:08:22 Integrated Voltage Measurement... 18:08:31 Voltage Offset Correction: v_off_ini = 738.844 uV, v_off_fin = 723.462 uV 18:08:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.237 uVs 18:08:31 Integrated Voltage Measurement... 18:08:40 Voltage Offset Correction: v_off_ini = 721.847 uV, v_off_fin = 752.584 uV 18:08:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.505 uVs 18:08:40 Integrated Voltage Measurement... 18:08:49 Voltage Offset Correction: v_off_ini = 754.224 uV, v_off_fin = 728.336 uV 18:08:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.228 uVs 18:08:49 Integrated Voltage Measurement... 18:08:58 Voltage Offset Correction: v_off_ini = 744.964 uV, v_off_fin = 748.399 uV 18:08:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.367 uVs 18:09:02 I1Y Average and RMS of Measurements VT = -197.794 +- 3.877 uVs I1Y = -39.559 +- 0.775 uTm 18:09:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:09:10 Integrated Voltage Measurement... 18:09:19 Voltage Offset Correction: v_off_ini = 745.837 uV, v_off_fin = 738.899 uV 18:09:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.487 uVs 18:09:19 Integrated Voltage Measurement... 18:09:28 Voltage Offset Correction: v_off_ini = 745.354 uV, v_off_fin = 743.490 uV 18:09:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.129 uVs 18:09:28 Integrated Voltage Measurement... 18:09:37 Voltage Offset Correction: v_off_ini = 743.979 uV, v_off_fin = 743.042 uV 18:09:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.562 uVs 18:09:37 Integrated Voltage Measurement... 18:09:46 Voltage Offset Correction: v_off_ini = 747.890 uV, v_off_fin = 757.415 uV 18:09:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.113 uVs 18:09:46 Integrated Voltage Measurement... 18:09:55 Voltage Offset Correction: v_off_ini = 753.250 uV, v_off_fin = 746.377 uV 18:09:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.739 uVs 18:09:55 Integrated Voltage Measurement... 18:10:04 Voltage Offset Correction: v_off_ini = 736.973 uV, v_off_fin = 732.392 uV 18:10:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.308 uVs 18:10:07 I2X Average and RMS of Measurements VT = -97.056 +- 4.518 uVs I2X = 8.929 +- 0.416 uTm^2 18:10:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:10:14 Integrated Voltage Measurement... 18:10:23 Voltage Offset Correction: v_off_ini = 747.370 uV, v_off_fin = 753.985 uV 18:10:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.477 uVs 18:10:23 Integrated Voltage Measurement... 18:10:32 Voltage Offset Correction: v_off_ini = 746.235 uV, v_off_fin = 747.503 uV 18:10:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.253 uVs 18:10:32 Integrated Voltage Measurement... 18:10:41 Voltage Offset Correction: v_off_ini = 748.871 uV, v_off_fin = 753.701 uV 18:10:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.605 uVs 18:10:41 Integrated Voltage Measurement... 18:10:50 Voltage Offset Correction: v_off_ini = 751.143 uV, v_off_fin = 752.350 uV 18:10:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.119 uVs 18:10:51 Integrated Voltage Measurement... 18:10:59 Voltage Offset Correction: v_off_ini = 744.979 uV, v_off_fin = 750.382 uV 18:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.179 uVs 18:11:00 Integrated Voltage Measurement... 18:11:09 Voltage Offset Correction: v_off_ini = 762.345 uV, v_off_fin = 764.322 uV 18:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.668 uVs 18:11:11 I2Y Average and RMS of Measurements VT = -303.217 +- 3.273 uVs I2Y = -27.896 +- 0.301 uTm^2 18:11:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:11:20 Integrated Voltage Measurement... 18:11:29 Voltage Offset Correction: v_off_ini = 755.383 uV, v_off_fin = 755.593 uV 18:11:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.493 uVs 18:11:29 Integrated Voltage Measurement... 18:11:38 Voltage Offset Correction: v_off_ini = 754.872 uV, v_off_fin = 756.282 uV 18:11:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.678 uVs 18:11:38 Integrated Voltage Measurement... 18:11:47 Voltage Offset Correction: v_off_ini = 748.166 uV, v_off_fin = 752.572 uV 18:11:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.231 uVs 18:11:47 Integrated Voltage Measurement... 18:11:56 Voltage Offset Correction: v_off_ini = 743.927 uV, v_off_fin = 752.293 uV 18:11:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.337 uVs 18:11:56 Integrated Voltage Measurement... 18:12:05 Voltage Offset Correction: v_off_ini = 751.278 uV, v_off_fin = 732.379 uV 18:12:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.270 uVs 18:12:05 Integrated Voltage Measurement... 18:12:14 Voltage Offset Correction: v_off_ini = 738.239 uV, v_off_fin = 738.148 uV 18:12:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.396 uVs 18:12:18 I1X Average and RMS of Measurements VT = -103.734 +- 4.707 uVs I1X = 20.747 +- 0.941 uTm 18:12:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:12:25 Integrated Voltage Measurement... 18:12:34 Voltage Offset Correction: v_off_ini = 751.161 uV, v_off_fin = 731.547 uV 18:12:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.506 uVs 18:12:34 Integrated Voltage Measurement... 18:12:43 Voltage Offset Correction: v_off_ini = 736.623 uV, v_off_fin = 747.268 uV 18:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.902 uVs 18:12:43 Integrated Voltage Measurement... 18:12:52 Voltage Offset Correction: v_off_ini = 733.516 uV, v_off_fin = 727.553 uV 18:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.940 uVs 18:12:52 Integrated Voltage Measurement... 18:13:01 Voltage Offset Correction: v_off_ini = 740.910 uV, v_off_fin = 745.392 uV 18:13:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.720 uVs 18:13:01 Integrated Voltage Measurement... 18:13:10 Voltage Offset Correction: v_off_ini = 742.354 uV, v_off_fin = 723.103 uV 18:13:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.900 uVs 18:13:10 Integrated Voltage Measurement... 18:13:19 Voltage Offset Correction: v_off_ini = 747.946 uV, v_off_fin = 756.038 uV 18:13:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.515 uVs 18:13:23 I1Y Average and RMS of Measurements VT = -208.747 +- 3.220 uVs I1Y = -41.749 +- 0.644 uTm 18:13:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:13:31 Integrated Voltage Measurement... 18:13:40 Voltage Offset Correction: v_off_ini = 739.705 uV, v_off_fin = 746.447 uV 18:13:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.366 uVs 18:13:40 Integrated Voltage Measurement... 18:13:49 Voltage Offset Correction: v_off_ini = 751.814 uV, v_off_fin = 761.102 uV 18:13:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.944 uVs 18:13:49 Integrated Voltage Measurement... 18:13:58 Voltage Offset Correction: v_off_ini = 752.966 uV, v_off_fin = 736.714 uV 18:13:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.939 uVs 18:13:58 Integrated Voltage Measurement... 18:14:07 Voltage Offset Correction: v_off_ini = 747.605 uV, v_off_fin = 760.744 uV 18:14:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.302 uVs 18:14:07 Integrated Voltage Measurement... 18:14:16 Voltage Offset Correction: v_off_ini = 739.172 uV, v_off_fin = 746.841 uV 18:14:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.844 uVs 18:14:16 Integrated Voltage Measurement... 18:14:25 Voltage Offset Correction: v_off_ini = 756.961 uV, v_off_fin = 759.536 uV 18:14:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.756 uVs 18:14:27 I2X Average and RMS of Measurements VT = -95.192 +- 5.812 uVs I2X = 8.758 +- 0.535 uTm^2 18:14:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:14:35 Integrated Voltage Measurement... 18:14:44 Voltage Offset Correction: v_off_ini = 755.888 uV, v_off_fin = 752.944 uV 18:14:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.333 uVs 18:14:44 Integrated Voltage Measurement... 18:14:53 Voltage Offset Correction: v_off_ini = 753.518 uV, v_off_fin = 750.427 uV 18:14:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.359 uVs 18:14:53 Integrated Voltage Measurement... 18:15:02 Voltage Offset Correction: v_off_ini = 749.230 uV, v_off_fin = 748.854 uV 18:15:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.756 uVs 18:15:02 Integrated Voltage Measurement... 18:15:11 Voltage Offset Correction: v_off_ini = 748.499 uV, v_off_fin = 742.655 uV 18:15:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.125 uVs 18:15:11 Integrated Voltage Measurement... 18:15:20 Voltage Offset Correction: v_off_ini = 737.352 uV, v_off_fin = 732.496 uV 18:15:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.897 uVs 18:15:20 Integrated Voltage Measurement... 18:15:29 Voltage Offset Correction: v_off_ini = 744.871 uV, v_off_fin = 745.199 uV 18:15:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.587 uVs 18:15:32 I2Y Average and RMS of Measurements VT = -305.009 +- 3.654 uVs I2Y = -28.061 +- 0.336 uTm^2 18:15:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:15:40 Integrated Voltage Measurement... 18:15:49 Voltage Offset Correction: v_off_ini = 745.284 uV, v_off_fin = 743.961 uV 18:15:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -99.389 uVs 18:15:49 Integrated Voltage Measurement... 18:15:58 Voltage Offset Correction: v_off_ini = 735.649 uV, v_off_fin = 755.975 uV 18:15:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.022 uVs 18:15:58 Integrated Voltage Measurement... 18:16:07 Voltage Offset Correction: v_off_ini = 739.936 uV, v_off_fin = 741.850 uV 18:16:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.070 uVs 18:16:07 Integrated Voltage Measurement... 18:16:16 Voltage Offset Correction: v_off_ini = 751.224 uV, v_off_fin = 758.074 uV 18:16:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.246 uVs 18:16:17 Integrated Voltage Measurement... 18:16:25 Voltage Offset Correction: v_off_ini = 747.383 uV, v_off_fin = 743.339 uV 18:16:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.405 uVs 18:16:26 Integrated Voltage Measurement... 18:16:34 Voltage Offset Correction: v_off_ini = 753.019 uV, v_off_fin = 759.901 uV 18:16:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.884 uVs 18:16:39 I1X Average and RMS of Measurements VT = -102.169 +- 4.568 uVs I1X = 20.435 +- 0.915 uTm 18:16:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:16:45 Integrated Voltage Measurement... 18:16:54 Voltage Offset Correction: v_off_ini = 758.289 uV, v_off_fin = 752.630 uV 18:16:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -202.048 uVs 18:16:54 Integrated Voltage Measurement... 18:17:03 Voltage Offset Correction: v_off_ini = 763.514 uV, v_off_fin = 763.061 uV 18:17:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.594 uVs 18:17:03 Integrated Voltage Measurement... 18:17:12 Voltage Offset Correction: v_off_ini = 746.308 uV, v_off_fin = 741.892 uV 18:17:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.669 uVs 18:17:12 Integrated Voltage Measurement... 18:17:21 Voltage Offset Correction: v_off_ini = 747.843 uV, v_off_fin = 755.925 uV 18:17:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.918 uVs 18:17:21 Integrated Voltage Measurement... 18:17:30 Voltage Offset Correction: v_off_ini = 758.287 uV, v_off_fin = 755.339 uV 18:17:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.991 uVs 18:17:30 Integrated Voltage Measurement... 18:17:39 Voltage Offset Correction: v_off_ini = 757.487 uV, v_off_fin = 765.749 uV 18:17:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.885 uVs 18:17:44 I1Y Average and RMS of Measurements VT = -197.518 +- 6.995 uVs I1Y = -39.505 +- 1.398 uTm 18:17:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:17:51 Integrated Voltage Measurement... 18:18:00 Voltage Offset Correction: v_off_ini = 756.935 uV, v_off_fin = 747.126 uV 18:18:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.573 uVs 18:18:00 Integrated Voltage Measurement... 18:18:09 Voltage Offset Correction: v_off_ini = 747.612 uV, v_off_fin = 762.094 uV 18:18:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.682 uVs 18:18:09 Integrated Voltage Measurement... 18:18:18 Voltage Offset Correction: v_off_ini = 743.484 uV, v_off_fin = 745.490 uV 18:18:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.610 uVs 18:18:18 Integrated Voltage Measurement... 18:18:27 Voltage Offset Correction: v_off_ini = 741.946 uV, v_off_fin = 752.208 uV 18:18:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.841 uVs 18:18:27 Integrated Voltage Measurement... 18:18:36 Voltage Offset Correction: v_off_ini = 739.209 uV, v_off_fin = 752.066 uV 18:18:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.833 uVs 18:18:36 Integrated Voltage Measurement... 18:18:45 Voltage Offset Correction: v_off_ini = 739.197 uV, v_off_fin = 737.960 uV 18:18:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.296 uVs 18:18:48 I2X Average and RMS of Measurements VT = -93.473 +- 5.608 uVs I2X = 8.600 +- 0.516 uTm^2 18:18:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:18:56 Integrated Voltage Measurement... 18:19:05 Voltage Offset Correction: v_off_ini = 741.326 uV, v_off_fin = 736.516 uV 18:19:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.576 uVs 18:19:05 Integrated Voltage Measurement... 18:19:14 Voltage Offset Correction: v_off_ini = 749.078 uV, v_off_fin = 742.990 uV 18:19:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.052 uVs 18:19:14 Integrated Voltage Measurement... 18:19:23 Voltage Offset Correction: v_off_ini = 733.685 uV, v_off_fin = 735.910 uV 18:19:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.677 uVs 18:19:23 Integrated Voltage Measurement... 18:19:32 Voltage Offset Correction: v_off_ini = 737.618 uV, v_off_fin = 738.768 uV 18:19:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.376 uVs 18:19:32 Integrated Voltage Measurement... 18:19:41 Voltage Offset Correction: v_off_ini = 750.461 uV, v_off_fin = 743.665 uV 18:19:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.113 uVs 18:19:41 Integrated Voltage Measurement... 18:19:50 Voltage Offset Correction: v_off_ini = 752.086 uV, v_off_fin = 742.328 uV 18:19:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.557 uVs 18:19:52 I2Y Average and RMS of Measurements VT = -309.059 +- 4.340 uVs I2Y = -28.433 +- 0.399 uTm^2 18:19:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:20:01 Integrated Voltage Measurement... 18:20:10 Voltage Offset Correction: v_off_ini = 757.247 uV, v_off_fin = 740.402 uV 18:20:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -105.526 uVs 18:20:10 Integrated Voltage Measurement... 18:20:19 Voltage Offset Correction: v_off_ini = 750.442 uV, v_off_fin = 754.242 uV 18:20:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.072 uVs 18:20:19 Integrated Voltage Measurement... 18:20:28 Voltage Offset Correction: v_off_ini = 737.560 uV, v_off_fin = 733.289 uV 18:20:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.672 uVs 18:20:28 Integrated Voltage Measurement... 18:20:37 Voltage Offset Correction: v_off_ini = 740.013 uV, v_off_fin = 743.484 uV 18:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.547 uVs 18:20:37 Integrated Voltage Measurement... 18:20:46 Voltage Offset Correction: v_off_ini = 724.117 uV, v_off_fin = 729.651 uV 18:20:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.267 uVs 18:20:46 Integrated Voltage Measurement... 18:20:55 Voltage Offset Correction: v_off_ini = 737.439 uV, v_off_fin = 730.706 uV 18:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.947 uVs 18:20:59 I1X Average and RMS of Measurements VT = -101.839 +- 7.497 uVs I1X = 20.369 +- 1.498 uTm 18:21:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:21:06 Integrated Voltage Measurement... 18:21:15 Voltage Offset Correction: v_off_ini = 743.140 uV, v_off_fin = 735.978 uV 18:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.875 uVs 18:21:15 Integrated Voltage Measurement... 18:21:24 Voltage Offset Correction: v_off_ini = 745.112 uV, v_off_fin = 752.170 uV 18:21:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.278 uVs 18:21:24 Integrated Voltage Measurement... 18:21:33 Voltage Offset Correction: v_off_ini = 742.460 uV, v_off_fin = 730.940 uV 18:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.394 uVs 18:21:33 Integrated Voltage Measurement... 18:21:42 Voltage Offset Correction: v_off_ini = 735.412 uV, v_off_fin = 739.775 uV 18:21:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.857 uVs 18:21:42 Integrated Voltage Measurement... 18:21:51 Voltage Offset Correction: v_off_ini = 726.184 uV, v_off_fin = 719.763 uV 18:21:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.881 uVs 18:21:51 Integrated Voltage Measurement... 18:22:00 Voltage Offset Correction: v_off_ini = 733.839 uV, v_off_fin = 740.936 uV 18:22:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.894 uVs 18:22:04 I1Y Average and RMS of Measurements VT = -216.697 +- 5.222 uVs I1Y = -43.339 +- 1.044 uTm 18:22:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:22:12 Integrated Voltage Measurement... 18:22:21 Voltage Offset Correction: v_off_ini = 724.560 uV, v_off_fin = 723.173 uV 18:22:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.470 uVs 18:22:21 Integrated Voltage Measurement... 18:22:30 Voltage Offset Correction: v_off_ini = 741.612 uV, v_off_fin = 748.419 uV 18:22:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.377 uVs 18:22:30 Integrated Voltage Measurement... 18:22:39 Voltage Offset Correction: v_off_ini = 752.283 uV, v_off_fin = 746.450 uV 18:22:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.935 uVs 18:22:39 Integrated Voltage Measurement... 18:22:48 Voltage Offset Correction: v_off_ini = 752.087 uV, v_off_fin = 750.753 uV 18:22:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.338 uVs 18:22:48 Integrated Voltage Measurement... 18:22:57 Voltage Offset Correction: v_off_ini = 742.011 uV, v_off_fin = 738.596 uV 18:22:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.270 uVs 18:22:57 Integrated Voltage Measurement... 18:23:06 Voltage Offset Correction: v_off_ini = 746.685 uV, v_off_fin = 754.997 uV 18:23:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.962 uVs 18:23:08 I2X Average and RMS of Measurements VT = -105.392 +- 2.744 uVs I2X = 9.696 +- 0.252 uTm^2 18:23:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:23:16 Integrated Voltage Measurement... 18:23:25 Voltage Offset Correction: v_off_ini = 736.214 uV, v_off_fin = 738.663 uV 18:23:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.752 uVs 18:23:25 Integrated Voltage Measurement... 18:23:34 Voltage Offset Correction: v_off_ini = 737.258 uV, v_off_fin = 735.015 uV 18:23:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.775 uVs 18:23:34 Integrated Voltage Measurement... 18:23:43 Voltage Offset Correction: v_off_ini = 743.567 uV, v_off_fin = 737.198 uV 18:23:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.495 uVs 18:23:43 Integrated Voltage Measurement... 18:23:52 Voltage Offset Correction: v_off_ini = 745.617 uV, v_off_fin = 732.492 uV 18:23:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.906 uVs 18:23:52 Integrated Voltage Measurement... 18:24:01 Voltage Offset Correction: v_off_ini = 727.176 uV, v_off_fin = 743.419 uV 18:24:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.350 uVs 18:24:01 Integrated Voltage Measurement... 18:24:10 Voltage Offset Correction: v_off_ini = 736.530 uV, v_off_fin = 739.043 uV 18:24:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 298.936 uVs 18:24:13 I2Y Average and RMS of Measurements VT = -316.702 +- 12.832 uVs I2Y = -29.137 +- 1.180 uTm^2 18:24:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:24:22 Integrated Voltage Measurement... 18:24:31 Voltage Offset Correction: v_off_ini = 736.912 uV, v_off_fin = 730.647 uV 18:24:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.686 uVs 18:24:31 Integrated Voltage Measurement... 18:24:40 Voltage Offset Correction: v_off_ini = 737.250 uV, v_off_fin = 739.652 uV 18:24:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.525 uVs 18:24:40 Integrated Voltage Measurement... 18:24:49 Voltage Offset Correction: v_off_ini = 727.125 uV, v_off_fin = 721.118 uV 18:24:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.722 uVs 18:24:49 Integrated Voltage Measurement... 18:24:58 Voltage Offset Correction: v_off_ini = 712.382 uV, v_off_fin = 733.680 uV 18:24:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.201 uVs 18:24:58 Integrated Voltage Measurement... 18:25:07 Voltage Offset Correction: v_off_ini = 721.118 uV, v_off_fin = 718.118 uV 18:25:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.782 uVs 18:25:07 Integrated Voltage Measurement... 18:25:16 Voltage Offset Correction: v_off_ini = 737.579 uV, v_off_fin = 738.311 uV 18:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.692 uVs 18:25:20 I1X Average and RMS of Measurements VT = -104.435 +- 3.458 uVs I1X = 20.887 +- 0.692 uTm 18:25:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:25:27 Integrated Voltage Measurement... 18:25:36 Voltage Offset Correction: v_off_ini = 723.612 uV, v_off_fin = 734.753 uV 18:25:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.104 uVs 18:25:36 Integrated Voltage Measurement... 18:25:45 Voltage Offset Correction: v_off_ini = 740.586 uV, v_off_fin = 750.882 uV 18:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.264 uVs 18:25:45 Integrated Voltage Measurement... 18:25:53 Voltage Offset Correction: v_off_ini = 731.327 uV, v_off_fin = 741.923 uV 18:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.605 uVs 18:25:54 Integrated Voltage Measurement... 18:26:02 Voltage Offset Correction: v_off_ini = 743.461 uV, v_off_fin = 744.894 uV 18:26:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.711 uVs 18:26:03 Integrated Voltage Measurement... 18:26:11 Voltage Offset Correction: v_off_ini = 735.755 uV, v_off_fin = 723.357 uV 18:26:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.293 uVs 18:26:12 Integrated Voltage Measurement... 18:26:20 Voltage Offset Correction: v_off_ini = 734.303 uV, v_off_fin = 742.670 uV 18:26:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.775 uVs 18:26:25 I1Y Average and RMS of Measurements VT = -201.459 +- 4.842 uVs I1Y = -40.292 +- 0.968 uTm 18:26:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:26:32 Integrated Voltage Measurement... 18:26:41 Voltage Offset Correction: v_off_ini = 719.851 uV, v_off_fin = 721.191 uV 18:26:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.696 uVs 18:26:41 Integrated Voltage Measurement... 18:26:50 Voltage Offset Correction: v_off_ini = 730.541 uV, v_off_fin = 739.280 uV 18:26:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.505 uVs 18:26:50 Integrated Voltage Measurement... 18:26:59 Voltage Offset Correction: v_off_ini = 716.293 uV, v_off_fin = 713.103 uV 18:26:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.462 uVs 18:27:00 Integrated Voltage Measurement... 18:27:08 Voltage Offset Correction: v_off_ini = 739.647 uV, v_off_fin = 730.733 uV 18:27:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.220 uVs 18:27:09 Integrated Voltage Measurement... 18:27:17 Voltage Offset Correction: v_off_ini = 729.193 uV, v_off_fin = 715.003 uV 18:27:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.017 uVs 18:27:18 Integrated Voltage Measurement... 18:27:27 Voltage Offset Correction: v_off_ini = 736.102 uV, v_off_fin = 741.777 uV 18:27:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.419 uVs 18:27:29 I2X Average and RMS of Measurements VT = -90.220 +- 2.642 uVs I2X = 8.300 +- 0.243 uTm^2 18:27:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:27:37 Integrated Voltage Measurement... 18:27:46 Voltage Offset Correction: v_off_ini = 732.406 uV, v_off_fin = 735.731 uV 18:27:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.497 uVs 18:27:46 Integrated Voltage Measurement... 18:27:55 Voltage Offset Correction: v_off_ini = 723.674 uV, v_off_fin = 726.402 uV 18:27:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.484 uVs 18:27:55 Integrated Voltage Measurement... 18:28:04 Voltage Offset Correction: v_off_ini = 736.286 uV, v_off_fin = 740.511 uV 18:28:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.321 uVs 18:28:04 Integrated Voltage Measurement... 18:28:13 Voltage Offset Correction: v_off_ini = 733.840 uV, v_off_fin = 738.407 uV 18:28:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.807 uVs 18:28:13 Integrated Voltage Measurement... 18:28:22 Voltage Offset Correction: v_off_ini = 739.851 uV, v_off_fin = 740.767 uV 18:28:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.738 uVs 18:28:22 Integrated Voltage Measurement... 18:28:31 Voltage Offset Correction: v_off_ini = 723.838 uV, v_off_fin = 724.286 uV 18:28:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.008 uVs 18:28:33 I2Y Average and RMS of Measurements VT = -309.309 +- 9.133 uVs I2Y = -28.456 +- 0.840 uTm^2 18:28:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:28:45 Integrated Voltage Measurement... 18:28:54 Voltage Offset Correction: v_off_ini = 720.726 uV, v_off_fin = 731.107 uV 18:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.764 uVs 18:28:54 Integrated Voltage Measurement... 18:29:03 Voltage Offset Correction: v_off_ini = 728.599 uV, v_off_fin = 734.395 uV 18:29:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.045 uVs 18:29:03 Integrated Voltage Measurement... 18:29:12 Voltage Offset Correction: v_off_ini = 735.747 uV, v_off_fin = 737.415 uV 18:29:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.153 uVs 18:29:12 Integrated Voltage Measurement... 18:29:21 Voltage Offset Correction: v_off_ini = 731.140 uV, v_off_fin = 721.372 uV 18:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.920 uVs 18:29:21 Integrated Voltage Measurement... 18:29:30 Voltage Offset Correction: v_off_ini = 717.026 uV, v_off_fin = 712.847 uV 18:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.582 uVs 18:29:30 Integrated Voltage Measurement... 18:29:39 Voltage Offset Correction: v_off_ini = 719.719 uV, v_off_fin = 719.373 uV 18:29:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.641 uVs 18:29:43 I1X Average and RMS of Measurements VT = -104.018 +- 9.514 uVs I1X = 20.804 +- 1.903 uTm 18:29:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:29:50 Integrated Voltage Measurement... 18:29:59 Voltage Offset Correction: v_off_ini = 726.803 uV, v_off_fin = 718.871 uV 18:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.207 uVs 18:29:59 Integrated Voltage Measurement... 18:30:08 Voltage Offset Correction: v_off_ini = 735.436 uV, v_off_fin = 733.902 uV 18:30:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.886 uVs 18:30:08 Integrated Voltage Measurement... 18:30:17 Voltage Offset Correction: v_off_ini = 727.122 uV, v_off_fin = 713.212 uV 18:30:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.223 uVs 18:30:17 Integrated Voltage Measurement... 18:30:26 Voltage Offset Correction: v_off_ini = 736.119 uV, v_off_fin = 744.748 uV 18:30:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.738 uVs 18:30:26 Integrated Voltage Measurement... 18:30:35 Voltage Offset Correction: v_off_ini = 739.801 uV, v_off_fin = 729.773 uV 18:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.622 uVs 18:30:35 Integrated Voltage Measurement... 18:30:44 Voltage Offset Correction: v_off_ini = 748.553 uV, v_off_fin = 757.424 uV 18:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.959 uVs 18:30:48 I1Y Average and RMS of Measurements VT = -198.606 +- 2.168 uVs I1Y = -39.721 +- 0.434 uTm 18:30:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:30:53 Integrated Voltage Measurement... 18:31:02 Voltage Offset Correction: v_off_ini = 717.116 uV, v_off_fin = 722.147 uV 18:31:02 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -87.740 uVs 18:31:02 Integrated Voltage Measurement... 18:31:11 Voltage Offset Correction: v_off_ini = 727.771 uV, v_off_fin = 743.283 uV 18:31:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.865 uVs 18:31:12 Integrated Voltage Measurement... 18:31:20 Voltage Offset Correction: v_off_ini = 748.072 uV, v_off_fin = 727.788 uV 18:31:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.685 uVs 18:31:21 Integrated Voltage Measurement... 18:31:30 Voltage Offset Correction: v_off_ini = 738.285 uV, v_off_fin = 746.188 uV 18:31:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.441 uVs 18:31:30 Integrated Voltage Measurement... 18:31:39 Voltage Offset Correction: v_off_ini = 732.339 uV, v_off_fin = 728.853 uV 18:31:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.136 uVs 18:31:39 Integrated Voltage Measurement... 18:31:48 Voltage Offset Correction: v_off_ini = 731.980 uV, v_off_fin = 731.984 uV 18:31:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.990 uVs 18:31:50 I2X Average and RMS of Measurements VT = -90.643 +- 2.008 uVs I2X = 8.339 +- 0.185 uTm^2 18:31:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:31:55 Integrated Voltage Measurement... 18:32:04 Voltage Offset Correction: v_off_ini = 736.303 uV, v_off_fin = 733.709 uV 18:32:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.613 uVs 18:32:04 Integrated Voltage Measurement... 18:32:13 Voltage Offset Correction: v_off_ini = 745.902 uV, v_off_fin = 745.681 uV 18:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.634 uVs 18:32:13 Integrated Voltage Measurement... 18:32:22 Voltage Offset Correction: v_off_ini = 745.695 uV, v_off_fin = 746.469 uV 18:32:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.346 uVs 18:32:22 Integrated Voltage Measurement... 18:32:31 Voltage Offset Correction: v_off_ini = 741.403 uV, v_off_fin = 744.723 uV 18:32:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.381 uVs 18:32:31 Integrated Voltage Measurement... 18:32:40 Voltage Offset Correction: v_off_ini = 738.617 uV, v_off_fin = 735.269 uV 18:32:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.062 uVs 18:32:40 Integrated Voltage Measurement... 18:32:49 Voltage Offset Correction: v_off_ini = 733.818 uV, v_off_fin = 748.981 uV 18:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.092 uVs 18:32:52 I2Y Average and RMS of Measurements VT = -306.021 +- 1.740 uVs I2Y = -28.154 +- 0.160 uTm^2 18:32:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:33:00 Integrated Voltage Measurement... 18:33:09 Voltage Offset Correction: v_off_ini = 732.127 uV, v_off_fin = 723.159 uV 18:33:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.788 uVs 18:33:09 Integrated Voltage Measurement... 18:33:18 Voltage Offset Correction: v_off_ini = 726.163 uV, v_off_fin = 734.476 uV 18:33:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.304 uVs 18:33:18 Integrated Voltage Measurement... 18:33:27 Voltage Offset Correction: v_off_ini = 703.313 uV, v_off_fin = 717.311 uV 18:33:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.317 uVs 18:33:27 Integrated Voltage Measurement... 18:33:36 Voltage Offset Correction: v_off_ini = 705.055 uV, v_off_fin = 721.345 uV 18:33:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.414 uVs 18:33:36 Integrated Voltage Measurement... 18:33:45 Voltage Offset Correction: v_off_ini = 730.252 uV, v_off_fin = 724.685 uV 18:33:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.018 uVs 18:33:45 Integrated Voltage Measurement... 18:33:54 Voltage Offset Correction: v_off_ini = 735.995 uV, v_off_fin = 743.933 uV 18:33:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.113 uVs 18:33:58 I1X Average and RMS of Measurements VT = -94.826 +- 14.780 uVs I1X = 18.965 +- 2.956 uTm 18:34:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:34:05 Integrated Voltage Measurement... 18:34:14 Voltage Offset Correction: v_off_ini = 742.163 uV, v_off_fin = 729.098 uV 18:34:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.826 uVs 18:34:14 Integrated Voltage Measurement... 18:34:23 Voltage Offset Correction: v_off_ini = 726.965 uV, v_off_fin = 729.299 uV 18:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.926 uVs 18:34:23 Integrated Voltage Measurement... 18:34:32 Voltage Offset Correction: v_off_ini = 742.097 uV, v_off_fin = 726.257 uV 18:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.511 uVs 18:34:32 Integrated Voltage Measurement... 18:34:41 Voltage Offset Correction: v_off_ini = 742.019 uV, v_off_fin = 740.391 uV 18:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.739 uVs 18:34:41 Integrated Voltage Measurement... 18:34:50 Voltage Offset Correction: v_off_ini = 730.039 uV, v_off_fin = 714.454 uV 18:34:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.861 uVs 18:34:50 Integrated Voltage Measurement... 18:34:59 Voltage Offset Correction: v_off_ini = 738.600 uV, v_off_fin = 739.817 uV 18:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.811 uVs 18:35:03 I1Y Average and RMS of Measurements VT = -199.279 +- 1.328 uVs I1Y = -39.856 +- 0.266 uTm 18:35:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:35:08 Integrated Voltage Measurement... 18:35:17 Voltage Offset Correction: v_off_ini = 718.888 uV, v_off_fin = 720.923 uV 18:35:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.979 uVs 18:35:17 Integrated Voltage Measurement... 18:35:26 Voltage Offset Correction: v_off_ini = 728.368 uV, v_off_fin = 731.453 uV 18:35:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.654 uVs 18:35:26 Integrated Voltage Measurement... 18:35:35 Voltage Offset Correction: v_off_ini = 728.207 uV, v_off_fin = 726.527 uV 18:35:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.790 uVs 18:35:35 Integrated Voltage Measurement... 18:35:44 Voltage Offset Correction: v_off_ini = 728.196 uV, v_off_fin = 730.587 uV 18:35:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.487 uVs 18:35:44 Integrated Voltage Measurement... 18:35:53 Voltage Offset Correction: v_off_ini = 719.623 uV, v_off_fin = 714.811 uV 18:35:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.953 uVs 18:35:53 Integrated Voltage Measurement... 18:36:02 Voltage Offset Correction: v_off_ini = 721.180 uV, v_off_fin = 736.478 uV 18:36:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.013 uVs 18:36:05 I2X Average and RMS of Measurements VT = -92.646 +- 3.541 uVs I2X = 8.524 +- 0.326 uTm^2 18:36:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:36:10 Integrated Voltage Measurement... 18:36:19 Voltage Offset Correction: v_off_ini = 733.451 uV, v_off_fin = 723.181 uV 18:36:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.839 uVs 18:36:19 Integrated Voltage Measurement... 18:36:28 Voltage Offset Correction: v_off_ini = 717.959 uV, v_off_fin = 725.815 uV 18:36:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.400 uVs 18:36:28 Integrated Voltage Measurement... 18:36:37 Voltage Offset Correction: v_off_ini = 714.335 uV, v_off_fin = 725.561 uV 18:36:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.202 uVs 18:36:37 Integrated Voltage Measurement... 18:36:46 Voltage Offset Correction: v_off_ini = 730.578 uV, v_off_fin = 734.164 uV 18:36:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.781 uVs 18:36:46 Integrated Voltage Measurement... 18:36:55 Voltage Offset Correction: v_off_ini = 732.450 uV, v_off_fin = 722.872 uV 18:36:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.424 uVs 18:36:55 Integrated Voltage Measurement... 18:37:04 Voltage Offset Correction: v_off_ini = 736.207 uV, v_off_fin = 728.812 uV 18:37:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.637 uVs 18:37:07 I2Y Average and RMS of Measurements VT = -303.380 +- 13.151 uVs I2Y = -27.911 +- 1.210 uTm^2 18:37:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:37:15 Integrated Voltage Measurement... 18:37:24 Voltage Offset Correction: v_off_ini = 732.160 uV, v_off_fin = 726.685 uV 18:37:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.696 uVs 18:37:24 Integrated Voltage Measurement... 18:37:33 Voltage Offset Correction: v_off_ini = 718.358 uV, v_off_fin = 720.237 uV 18:37:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.476 uVs 18:37:33 Integrated Voltage Measurement... 18:37:42 Voltage Offset Correction: v_off_ini = 722.404 uV, v_off_fin = 728.324 uV 18:37:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.373 uVs 18:37:42 Integrated Voltage Measurement... 18:37:51 Voltage Offset Correction: v_off_ini = 719.870 uV, v_off_fin = 725.427 uV 18:37:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.184 uVs 18:37:51 Integrated Voltage Measurement... 18:38:00 Voltage Offset Correction: v_off_ini = 715.994 uV, v_off_fin = 716.950 uV 18:38:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.035 uVs 18:38:00 Integrated Voltage Measurement... 18:38:09 Voltage Offset Correction: v_off_ini = 721.044 uV, v_off_fin = 723.761 uV 18:38:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.359 uVs 18:38:13 I1X Average and RMS of Measurements VT = -110.521 +- 3.308 uVs I1X = 22.105 +- 0.661 uTm 18:38:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:38:20 Integrated Voltage Measurement... 18:38:29 Voltage Offset Correction: v_off_ini = 715.747 uV, v_off_fin = 715.045 uV 18:38:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.752 uVs 18:38:29 Integrated Voltage Measurement... 18:38:38 Voltage Offset Correction: v_off_ini = 729.505 uV, v_off_fin = 730.766 uV 18:38:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.173 uVs 18:38:38 Integrated Voltage Measurement... 18:38:47 Voltage Offset Correction: v_off_ini = 718.641 uV, v_off_fin = 715.087 uV 18:38:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.083 uVs 18:38:47 Integrated Voltage Measurement... 18:38:56 Voltage Offset Correction: v_off_ini = 726.059 uV, v_off_fin = 730.466 uV 18:38:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.167 uVs 18:38:56 Integrated Voltage Measurement... 18:39:05 Voltage Offset Correction: v_off_ini = 731.384 uV, v_off_fin = 709.070 uV 18:39:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.589 uVs 18:39:05 Integrated Voltage Measurement... 18:39:14 Voltage Offset Correction: v_off_ini = 732.467 uV, v_off_fin = 742.553 uV 18:39:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.350 uVs 18:39:18 I1Y Average and RMS of Measurements VT = -196.352 +- 2.601 uVs I1Y = -39.270 +- 0.520 uTm 18:39:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:39:23 Integrated Voltage Measurement... 18:39:32 Voltage Offset Correction: v_off_ini = 720.648 uV, v_off_fin = 729.719 uV 18:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.029 uVs 18:39:32 Integrated Voltage Measurement... 18:39:41 Voltage Offset Correction: v_off_ini = 738.430 uV, v_off_fin = 747.187 uV 18:39:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.568 uVs 18:39:41 Integrated Voltage Measurement... 18:39:50 Voltage Offset Correction: v_off_ini = 738.811 uV, v_off_fin = 737.221 uV 18:39:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.174 uVs 18:39:50 Integrated Voltage Measurement... 18:39:59 Voltage Offset Correction: v_off_ini = 744.274 uV, v_off_fin = 744.259 uV 18:39:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.763 uVs 18:39:59 Integrated Voltage Measurement... 18:40:08 Voltage Offset Correction: v_off_ini = 745.701 uV, v_off_fin = 725.630 uV 18:40:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.546 uVs 18:40:08 Integrated Voltage Measurement... 18:40:17 Voltage Offset Correction: v_off_ini = 721.951 uV, v_off_fin = 734.941 uV 18:40:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.084 uVs 18:40:20 I2X Average and RMS of Measurements VT = -95.194 +- 3.000 uVs I2X = 8.758 +- 0.276 uTm^2 18:40:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:40:25 Integrated Voltage Measurement... 18:40:34 Voltage Offset Correction: v_off_ini = 731.899 uV, v_off_fin = 734.871 uV 18:40:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.391 uVs 18:40:34 Integrated Voltage Measurement... 18:40:43 Voltage Offset Correction: v_off_ini = 745.435 uV, v_off_fin = 743.134 uV 18:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.960 uVs 18:40:43 Integrated Voltage Measurement... 18:40:52 Voltage Offset Correction: v_off_ini = 747.391 uV, v_off_fin = 733.804 uV 18:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.255 uVs 18:40:52 Integrated Voltage Measurement... 18:41:01 Voltage Offset Correction: v_off_ini = 735.864 uV, v_off_fin = 746.140 uV 18:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.250 uVs 18:41:01 Integrated Voltage Measurement... 18:41:10 Voltage Offset Correction: v_off_ini = 744.949 uV, v_off_fin = 739.968 uV 18:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.941 uVs 18:41:10 Integrated Voltage Measurement... 18:41:19 Voltage Offset Correction: v_off_ini = 721.192 uV, v_off_fin = 733.773 uV 18:41:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.159 uVs 18:41:21 I2Y Average and RMS of Measurements VT = -312.826 +- 6.446 uVs I2Y = -28.780 +- 0.593 uTm^2 18:41:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:41:30 Integrated Voltage Measurement... 18:41:39 Voltage Offset Correction: v_off_ini = 732.716 uV, v_off_fin = 737.821 uV 18:41:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.379 uVs 18:41:39 Integrated Voltage Measurement... 18:41:48 Voltage Offset Correction: v_off_ini = 740.006 uV, v_off_fin = 736.950 uV 18:41:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.950 uVs 18:41:48 Integrated Voltage Measurement... 18:41:57 Voltage Offset Correction: v_off_ini = 739.427 uV, v_off_fin = 730.403 uV 18:41:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.572 uVs 18:41:57 Integrated Voltage Measurement... 18:42:06 Voltage Offset Correction: v_off_ini = 731.255 uV, v_off_fin = 730.930 uV 18:42:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.599 uVs 18:42:06 Integrated Voltage Measurement... 18:42:15 Voltage Offset Correction: v_off_ini = 725.914 uV, v_off_fin = 738.364 uV 18:42:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.864 uVs 18:42:15 Integrated Voltage Measurement... 18:42:24 Voltage Offset Correction: v_off_ini = 737.411 uV, v_off_fin = 725.472 uV 18:42:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.016 uVs 18:42:28 I1X Average and RMS of Measurements VT = -100.563 +- 2.845 uVs I1X = 20.113 +- 0.569 uTm 18:42:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:42:35 Integrated Voltage Measurement... 18:42:44 Voltage Offset Correction: v_off_ini = 740.992 uV, v_off_fin = 730.515 uV 18:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.110 uVs 18:42:44 Integrated Voltage Measurement... 18:42:53 Voltage Offset Correction: v_off_ini = 740.463 uV, v_off_fin = 740.849 uV 18:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.535 uVs 18:42:53 Integrated Voltage Measurement... 18:43:02 Voltage Offset Correction: v_off_ini = 747.113 uV, v_off_fin = 726.911 uV 18:43:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.663 uVs 18:43:02 Integrated Voltage Measurement... 18:43:11 Voltage Offset Correction: v_off_ini = 722.637 uV, v_off_fin = 738.933 uV 18:43:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.565 uVs 18:43:11 Integrated Voltage Measurement... 18:43:20 Voltage Offset Correction: v_off_ini = 734.414 uV, v_off_fin = 721.228 uV 18:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.389 uVs 18:43:20 Integrated Voltage Measurement... 18:43:29 Voltage Offset Correction: v_off_ini = 728.492 uV, v_off_fin = 735.844 uV 18:43:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.972 uVs 18:43:33 I1Y Average and RMS of Measurements VT = -204.706 +- 6.100 uVs I1Y = -40.939 +- 1.222 uTm 18:43:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:43:38 Integrated Voltage Measurement... 18:43:47 Voltage Offset Correction: v_off_ini = 738.330 uV, v_off_fin = 714.917 uV 18:43:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.964 uVs 18:43:47 Integrated Voltage Measurement... 18:43:56 Voltage Offset Correction: v_off_ini = 730.001 uV, v_off_fin = 734.050 uV 18:43:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.908 uVs 18:43:56 Integrated Voltage Measurement... 18:44:05 Voltage Offset Correction: v_off_ini = 736.806 uV, v_off_fin = 729.163 uV 18:44:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.184 uVs 18:44:05 Integrated Voltage Measurement... 18:44:14 Voltage Offset Correction: v_off_ini = 731.410 uV, v_off_fin = 736.229 uV 18:44:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.255 uVs 18:44:14 Integrated Voltage Measurement... 18:44:23 Voltage Offset Correction: v_off_ini = 747.094 uV, v_off_fin = 726.713 uV 18:44:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.985 uVs 18:44:23 Integrated Voltage Measurement... 18:44:32 Voltage Offset Correction: v_off_ini = 728.658 uV, v_off_fin = 741.656 uV 18:44:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.091 uVs 18:44:34 I2X Average and RMS of Measurements VT = -97.231 +- 6.353 uVs I2X = 8.945 +- 0.585 uTm^2 18:44:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:44:40 Integrated Voltage Measurement... 18:44:48 Voltage Offset Correction: v_off_ini = 741.465 uV, v_off_fin = 743.626 uV 18:44:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.238 uVs 18:44:49 Integrated Voltage Measurement... 18:44:58 Voltage Offset Correction: v_off_ini = 729.506 uV, v_off_fin = 735.241 uV 18:44:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.980 uVs 18:44:58 Integrated Voltage Measurement... 18:45:07 Voltage Offset Correction: v_off_ini = 728.121 uV, v_off_fin = 724.184 uV 18:45:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.961 uVs 18:45:07 Integrated Voltage Measurement... 18:45:16 Voltage Offset Correction: v_off_ini = 731.797 uV, v_off_fin = 727.623 uV 18:45:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.203 uVs 18:45:16 Integrated Voltage Measurement... 18:45:25 Voltage Offset Correction: v_off_ini = 724.760 uV, v_off_fin = 718.653 uV 18:45:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.412 uVs 18:45:25 Integrated Voltage Measurement... 18:45:34 Voltage Offset Correction: v_off_ini = 726.182 uV, v_off_fin = 723.514 uV 18:45:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.200 uVs 18:45:36 I2Y Average and RMS of Measurements VT = -308.332 +- 7.815 uVs I2Y = -28.367 +- 0.719 uTm^2 18:45:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:45:44 Integrated Voltage Measurement... 18:45:53 Voltage Offset Correction: v_off_ini = 715.116 uV, v_off_fin = 727.308 uV 18:45:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.544 uVs 18:45:53 Integrated Voltage Measurement... 18:46:02 Voltage Offset Correction: v_off_ini = 722.321 uV, v_off_fin = 718.263 uV 18:46:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.278 uVs 18:46:02 Integrated Voltage Measurement... 18:46:11 Voltage Offset Correction: v_off_ini = 730.765 uV, v_off_fin = 717.066 uV 18:46:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.689 uVs 18:46:11 Integrated Voltage Measurement... 18:46:20 Voltage Offset Correction: v_off_ini = 722.392 uV, v_off_fin = 725.208 uV 18:46:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 93.967 uVs 18:46:20 Integrated Voltage Measurement... 18:46:29 Voltage Offset Correction: v_off_ini = 719.738 uV, v_off_fin = 722.215 uV 18:46:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.385 uVs 18:46:29 Integrated Voltage Measurement... 18:46:38 Voltage Offset Correction: v_off_ini = 726.822 uV, v_off_fin = 727.960 uV 18:46:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.649 uVs 18:46:43 I1X Average and RMS of Measurements VT = -95.252 +- 6.032 uVs I1X = 19.051 +- 1.206 uTm 18:46:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:46:49 Integrated Voltage Measurement... 18:46:58 Voltage Offset Correction: v_off_ini = 722.789 uV, v_off_fin = 711.906 uV 18:46:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.109 uVs 18:46:58 Integrated Voltage Measurement... 18:47:07 Voltage Offset Correction: v_off_ini = 717.427 uV, v_off_fin = 716.990 uV 18:47:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.111 uVs 18:47:07 Integrated Voltage Measurement... 18:47:16 Voltage Offset Correction: v_off_ini = 708.647 uV, v_off_fin = 705.955 uV 18:47:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.535 uVs 18:47:16 Integrated Voltage Measurement... 18:47:25 Voltage Offset Correction: v_off_ini = 707.302 uV, v_off_fin = 730.454 uV 18:47:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.304 uVs 18:47:25 Integrated Voltage Measurement... 18:47:34 Voltage Offset Correction: v_off_ini = 714.869 uV, v_off_fin = 709.507 uV 18:47:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.358 uVs 18:47:34 Integrated Voltage Measurement... 18:47:43 Voltage Offset Correction: v_off_ini = 715.207 uV, v_off_fin = 719.724 uV 18:47:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.991 uVs 18:47:48 I1Y Average and RMS of Measurements VT = -204.068 +- 4.114 uVs I1Y = -40.811 +- 0.822 uTm 18:47:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:47:53 Integrated Voltage Measurement... 18:48:02 Voltage Offset Correction: v_off_ini = 713.300 uV, v_off_fin = 714.228 uV 18:48:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.421 uVs 18:48:02 Integrated Voltage Measurement... 18:48:11 Voltage Offset Correction: v_off_ini = 711.510 uV, v_off_fin = 724.948 uV 18:48:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.857 uVs 18:48:11 Integrated Voltage Measurement... 18:48:20 Voltage Offset Correction: v_off_ini = 721.498 uV, v_off_fin = 711.910 uV 18:48:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.620 uVs 18:48:20 Integrated Voltage Measurement... 18:48:29 Voltage Offset Correction: v_off_ini = 712.483 uV, v_off_fin = 733.860 uV 18:48:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.315 uVs 18:48:29 Integrated Voltage Measurement... 18:48:38 Voltage Offset Correction: v_off_ini = 726.016 uV, v_off_fin = 727.749 uV 18:48:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.548 uVs 18:48:38 Integrated Voltage Measurement... 18:48:47 Voltage Offset Correction: v_off_ini = 731.369 uV, v_off_fin = 726.161 uV 18:48:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.468 uVs 18:48:49 I2X Average and RMS of Measurements VT = -95.705 +- 6.259 uVs I2X = 8.805 +- 0.576 uTm^2 18:48:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:48:54 Integrated Voltage Measurement... 18:49:03 Voltage Offset Correction: v_off_ini = 730.258 uV, v_off_fin = 721.829 uV 18:49:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.376 uVs 18:49:03 Integrated Voltage Measurement... 18:49:12 Voltage Offset Correction: v_off_ini = 727.194 uV, v_off_fin = 721.840 uV 18:49:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.735 uVs 18:49:12 Integrated Voltage Measurement... 18:49:21 Voltage Offset Correction: v_off_ini = 716.730 uV, v_off_fin = 719.037 uV 18:49:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.684 uVs 18:49:21 Integrated Voltage Measurement... 18:49:30 Voltage Offset Correction: v_off_ini = 723.397 uV, v_off_fin = 724.787 uV 18:49:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.671 uVs 18:49:30 Integrated Voltage Measurement... 18:49:39 Voltage Offset Correction: v_off_ini = 708.826 uV, v_off_fin = 723.189 uV 18:49:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.278 uVs 18:49:40 Integrated Voltage Measurement... 18:49:49 Voltage Offset Correction: v_off_ini = 723.539 uV, v_off_fin = 717.739 uV 18:49:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.801 uVs 18:49:51 I2Y Average and RMS of Measurements VT = -298.424 +- 3.800 uVs I2Y = -27.455 +- 0.350 uTm^2 18:49:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:34:26 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm