SLAC Magnetic Measurements Date: 07-18-2025 Time: 11:06:00 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16353 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 13 Measurement Device: Operator: YL Comment: 11:06:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:11 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:13 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:14 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:16 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:30 Integrated Voltage Measurement... 11:06:39 Voltage Offset Correction: v_off_ini = 468.507 uV, v_off_fin = 457.979 uV 11:06:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.991 uVs 11:06:39 Integrated Voltage Measurement... 11:06:48 Voltage Offset Correction: v_off_ini = 460.537 uV, v_off_fin = 452.095 uV 11:06:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.954 uVs 11:06:48 Integrated Voltage Measurement... 11:06:57 Voltage Offset Correction: v_off_ini = 472.302 uV, v_off_fin = 458.460 uV 11:06:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.011 uVs 11:06:57 Integrated Voltage Measurement... 11:07:06 Voltage Offset Correction: v_off_ini = 453.907 uV, v_off_fin = 463.216 uV 11:07:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.250 uVs 11:07:06 Integrated Voltage Measurement... 11:07:15 Voltage Offset Correction: v_off_ini = 471.803 uV, v_off_fin = 458.131 uV 11:07:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -71.574 uVs 11:07:15 Integrated Voltage Measurement... 11:07:24 Voltage Offset Correction: v_off_ini = 466.052 uV, v_off_fin = 466.625 uV 11:07:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.934 uVs 11:07:29 I1X Average and RMS of Measurements VT = -71.619 +- 7.506 uVs I1X = 14.324 +- 1.501 uTm 11:07:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:07:35 Integrated Voltage Measurement... 11:07:44 Voltage Offset Correction: v_off_ini = 473.745 uV, v_off_fin = 466.509 uV 11:07:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.909 uVs 11:07:44 Integrated Voltage Measurement... 11:07:53 Voltage Offset Correction: v_off_ini = 470.067 uV, v_off_fin = 486.771 uV 11:07:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.894 uVs 11:07:53 Integrated Voltage Measurement... 11:08:02 Voltage Offset Correction: v_off_ini = 482.775 uV, v_off_fin = 478.336 uV 11:08:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.722 uVs 11:08:02 Integrated Voltage Measurement... 11:08:11 Voltage Offset Correction: v_off_ini = 470.738 uV, v_off_fin = 480.052 uV 11:08:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.713 uVs 11:08:11 Integrated Voltage Measurement... 11:08:20 Voltage Offset Correction: v_off_ini = 478.836 uV, v_off_fin = 470.031 uV 11:08:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.544 uVs 11:08:20 Integrated Voltage Measurement... 11:08:29 Voltage Offset Correction: v_off_ini = 486.432 uV, v_off_fin = 479.113 uV 11:08:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.913 uVs 11:08:34 I1Y Average and RMS of Measurements VT = -180.949 +- 4.214 uVs I1Y = -36.189 +- 0.843 uTm 11:08:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:41 Integrated Voltage Measurement... 11:08:50 Voltage Offset Correction: v_off_ini = 497.275 uV, v_off_fin = 481.627 uV 11:08:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -29.789 uVs 11:08:50 Integrated Voltage Measurement... 11:08:59 Voltage Offset Correction: v_off_ini = 498.897 uV, v_off_fin = 493.633 uV 11:08:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.490 uVs 11:08:59 Integrated Voltage Measurement... 11:09:08 Voltage Offset Correction: v_off_ini = 478.125 uV, v_off_fin = 477.885 uV 11:09:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.728 uVs 11:09:09 Integrated Voltage Measurement... 11:09:18 Voltage Offset Correction: v_off_ini = 471.780 uV, v_off_fin = 464.170 uV 11:09:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.513 uVs 11:09:18 Integrated Voltage Measurement... 11:09:27 Voltage Offset Correction: v_off_ini = 462.168 uV, v_off_fin = 468.505 uV 11:09:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.349 uVs 11:09:27 Integrated Voltage Measurement... 11:09:36 Voltage Offset Correction: v_off_ini = 461.602 uV, v_off_fin = 464.652 uV 11:09:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.938 uVs 11:09:38 I2X Average and RMS of Measurements VT = -31.968 +- 8.345 uVs I2X = 2.941 +- 0.768 uTm^2 11:09:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:46 Integrated Voltage Measurement... 11:09:55 Voltage Offset Correction: v_off_ini = 460.923 uV, v_off_fin = 469.024 uV 11:09:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -519.215 uVs 11:09:55 Integrated Voltage Measurement... 11:10:04 Voltage Offset Correction: v_off_ini = 469.185 uV, v_off_fin = 466.981 uV 11:10:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 529.500 uVs 11:10:04 Integrated Voltage Measurement... 11:10:13 Voltage Offset Correction: v_off_ini = 480.228 uV, v_off_fin = 473.357 uV 11:10:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -541.898 uVs 11:10:13 Integrated Voltage Measurement... 11:10:22 Voltage Offset Correction: v_off_ini = 461.571 uV, v_off_fin = 464.870 uV 11:10:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 539.600 uVs 11:10:22 Integrated Voltage Measurement... 11:10:31 Voltage Offset Correction: v_off_ini = 466.783 uV, v_off_fin = 465.550 uV 11:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -533.766 uVs 11:10:31 Integrated Voltage Measurement... 11:10:40 Voltage Offset Correction: v_off_ini = 473.021 uV, v_off_fin = 465.311 uV 11:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.088 uVs 11:10:42 I2Y Average and RMS of Measurements VT = -529.012 +- 8.359 uVs I2Y = -48.670 +- 0.769 uTm^2 11:10:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:57 Integrated Voltage Measurement... 11:11:06 Voltage Offset Correction: v_off_ini = 475.622 uV, v_off_fin = 474.189 uV 11:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.061 uVs 11:11:06 Integrated Voltage Measurement... 11:11:15 Voltage Offset Correction: v_off_ini = 473.263 uV, v_off_fin = 471.431 uV 11:11:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.769 uVs 11:11:15 Integrated Voltage Measurement... 11:11:24 Voltage Offset Correction: v_off_ini = 473.517 uV, v_off_fin = 474.115 uV 11:11:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -66.618 uVs 11:11:24 Integrated Voltage Measurement... 11:11:33 Voltage Offset Correction: v_off_ini = 467.939 uV, v_off_fin = 466.198 uV 11:11:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.852 uVs 11:11:34 Integrated Voltage Measurement... 11:11:42 Voltage Offset Correction: v_off_ini = 470.980 uV, v_off_fin = 478.051 uV 11:11:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.938 uVs 11:11:43 Integrated Voltage Measurement... 11:11:52 Voltage Offset Correction: v_off_ini = 470.388 uV, v_off_fin = 471.438 uV 11:11:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.049 uVs 11:11:56 I1X Average and RMS of Measurements VT = -82.214 +- 5.435 uVs I1X = 16.444 +- 1.087 uTm 11:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:03 Integrated Voltage Measurement... 11:12:12 Voltage Offset Correction: v_off_ini = 488.045 uV, v_off_fin = 471.712 uV 11:12:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.767 uVs 11:12:12 Integrated Voltage Measurement... 11:12:21 Voltage Offset Correction: v_off_ini = 475.009 uV, v_off_fin = 486.360 uV 11:12:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 192.928 uVs 11:12:21 Integrated Voltage Measurement... 11:12:30 Voltage Offset Correction: v_off_ini = 481.526 uV, v_off_fin = 479.116 uV 11:12:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.507 uVs 11:12:30 Integrated Voltage Measurement... 11:12:39 Voltage Offset Correction: v_off_ini = 489.449 uV, v_off_fin = 504.427 uV 11:12:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.493 uVs 11:12:39 Integrated Voltage Measurement... 11:12:48 Voltage Offset Correction: v_off_ini = 493.085 uV, v_off_fin = 482.079 uV 11:12:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.968 uVs 11:12:48 Integrated Voltage Measurement... 11:12:57 Voltage Offset Correction: v_off_ini = 503.938 uV, v_off_fin = 504.217 uV 11:12:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.670 uVs 11:13:01 I1Y Average and RMS of Measurements VT = -194.722 +- 4.086 uVs I1Y = -38.942 +- 0.816 uTm 11:13:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:09 Integrated Voltage Measurement... 11:13:18 Voltage Offset Correction: v_off_ini = 485.121 uV, v_off_fin = 476.958 uV 11:13:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.780 uVs 11:13:18 Integrated Voltage Measurement... 11:13:27 Voltage Offset Correction: v_off_ini = 487.166 uV, v_off_fin = 491.641 uV 11:13:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.374 uVs 11:13:27 Integrated Voltage Measurement... 11:13:36 Voltage Offset Correction: v_off_ini = 499.296 uV, v_off_fin = 481.321 uV 11:13:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.765 uVs 11:13:36 Integrated Voltage Measurement... 11:13:45 Voltage Offset Correction: v_off_ini = 501.777 uV, v_off_fin = 497.598 uV 11:13:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.939 uVs 11:13:45 Integrated Voltage Measurement... 11:13:54 Voltage Offset Correction: v_off_ini = 492.688 uV, v_off_fin = 489.528 uV 11:13:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.755 uVs 11:13:54 Integrated Voltage Measurement... 11:14:03 Voltage Offset Correction: v_off_ini = 505.079 uV, v_off_fin = 508.332 uV 11:14:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.890 uVs 11:14:05 I2X Average and RMS of Measurements VT = -52.584 +- 6.215 uVs I2X = 4.838 +- 0.572 uTm^2 11:14:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:14:13 Integrated Voltage Measurement... 11:14:22 Voltage Offset Correction: v_off_ini = 493.658 uV, v_off_fin = 499.438 uV 11:14:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -514.544 uVs 11:14:22 Integrated Voltage Measurement... 11:14:31 Voltage Offset Correction: v_off_ini = 491.728 uV, v_off_fin = 492.196 uV 11:14:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.356 uVs 11:14:31 Integrated Voltage Measurement... 11:14:40 Voltage Offset Correction: v_off_ini = 491.549 uV, v_off_fin = 484.318 uV 11:14:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -535.983 uVs 11:14:40 Integrated Voltage Measurement... 11:14:49 Voltage Offset Correction: v_off_ini = 498.399 uV, v_off_fin = 502.088 uV 11:14:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.219 uVs 11:14:49 Integrated Voltage Measurement... 11:14:58 Voltage Offset Correction: v_off_ini = 494.946 uV, v_off_fin = 493.615 uV 11:14:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -531.027 uVs 11:14:58 Integrated Voltage Measurement... 11:15:07 Voltage Offset Correction: v_off_ini = 509.459 uV, v_off_fin = 497.498 uV 11:15:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.428 uVs 11:15:10 I2Y Average and RMS of Measurements VT = -516.259 +- 7.439 uVs I2Y = -47.496 +- 0.684 uTm^2 11:15:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:25 Integrated Voltage Measurement... 11:15:33 Voltage Offset Correction: v_off_ini = 492.119 uV, v_off_fin = 484.340 uV 11:15:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.579 uVs 11:15:34 Integrated Voltage Measurement... 11:15:43 Voltage Offset Correction: v_off_ini = 490.394 uV, v_off_fin = 484.448 uV 11:15:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.700 uVs 11:15:43 Integrated Voltage Measurement... 11:15:52 Voltage Offset Correction: v_off_ini = 485.064 uV, v_off_fin = 482.302 uV 11:15:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.039 uVs 11:15:52 Integrated Voltage Measurement... 11:16:01 Voltage Offset Correction: v_off_ini = 489.760 uV, v_off_fin = 498.602 uV 11:16:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.293 uVs 11:16:01 Integrated Voltage Measurement... 11:16:10 Voltage Offset Correction: v_off_ini = 487.511 uV, v_off_fin = 479.634 uV 11:16:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.313 uVs 11:16:10 Integrated Voltage Measurement... 11:16:19 Voltage Offset Correction: v_off_ini = 483.890 uV, v_off_fin = 494.704 uV 11:16:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 76.980 uVs 11:16:23 I1X Average and RMS of Measurements VT = -95.484 +- 14.874 uVs I1X = 19.098 +- 2.974 uTm 11:16:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:16:30 Integrated Voltage Measurement... 11:16:39 Voltage Offset Correction: v_off_ini = 497.160 uV, v_off_fin = 486.546 uV 11:16:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.889 uVs 11:16:39 Integrated Voltage Measurement... 11:16:48 Voltage Offset Correction: v_off_ini = 486.571 uV, v_off_fin = 505.319 uV 11:16:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 205.883 uVs 11:16:48 Integrated Voltage Measurement... 11:16:57 Voltage Offset Correction: v_off_ini = 488.856 uV, v_off_fin = 470.755 uV 11:16:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -191.559 uVs 11:16:57 Integrated Voltage Measurement... 11:17:06 Voltage Offset Correction: v_off_ini = 482.097 uV, v_off_fin = 494.068 uV 11:17:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.848 uVs 11:17:06 Integrated Voltage Measurement... 11:17:15 Voltage Offset Correction: v_off_ini = 493.850 uV, v_off_fin = 473.203 uV 11:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.709 uVs 11:17:15 Integrated Voltage Measurement... 11:17:24 Voltage Offset Correction: v_off_ini = 495.114 uV, v_off_fin = 511.747 uV 11:17:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.478 uVs 11:17:28 I1Y Average and RMS of Measurements VT = -194.894 +- 1.975 uVs I1Y = -38.974 +- 0.396 uTm 11:17:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:36 Integrated Voltage Measurement... 11:17:45 Voltage Offset Correction: v_off_ini = 469.478 uV, v_off_fin = 472.002 uV 11:17:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -27.107 uVs 11:17:45 Integrated Voltage Measurement... 11:17:54 Voltage Offset Correction: v_off_ini = 491.802 uV, v_off_fin = 502.530 uV 11:17:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.740 uVs 11:17:54 Integrated Voltage Measurement... 11:18:03 Voltage Offset Correction: v_off_ini = 487.245 uV, v_off_fin = 480.119 uV 11:18:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.352 uVs 11:18:03 Integrated Voltage Measurement... 11:18:12 Voltage Offset Correction: v_off_ini = 482.684 uV, v_off_fin = 489.465 uV 11:18:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 54.339 uVs 11:18:12 Integrated Voltage Measurement... 11:18:21 Voltage Offset Correction: v_off_ini = 498.593 uV, v_off_fin = 480.084 uV 11:18:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -59.506 uVs 11:18:21 Integrated Voltage Measurement... 11:18:30 Voltage Offset Correction: v_off_ini = 497.719 uV, v_off_fin = 499.872 uV 11:18:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.151 uVs 11:18:32 I2X Average and RMS of Measurements VT = -50.699 +- 4.068 uVs I2X = 4.665 +- 0.374 uTm^2 11:18:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:40 Integrated Voltage Measurement... 11:18:49 Voltage Offset Correction: v_off_ini = 493.990 uV, v_off_fin = 490.645 uV 11:18:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -516.346 uVs 11:18:49 Integrated Voltage Measurement... 11:18:58 Voltage Offset Correction: v_off_ini = 479.331 uV, v_off_fin = 484.599 uV 11:18:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.678 uVs 11:18:58 Integrated Voltage Measurement... 11:19:07 Voltage Offset Correction: v_off_ini = 486.275 uV, v_off_fin = 483.174 uV 11:19:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.730 uVs 11:19:07 Integrated Voltage Measurement... 11:19:16 Voltage Offset Correction: v_off_ini = 485.255 uV, v_off_fin = 483.076 uV 11:19:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 498.094 uVs 11:19:16 Integrated Voltage Measurement... 11:19:25 Voltage Offset Correction: v_off_ini = 464.963 uV, v_off_fin = 450.773 uV 11:19:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.235 uVs 11:19:25 Integrated Voltage Measurement... 11:19:34 Voltage Offset Correction: v_off_ini = 471.449 uV, v_off_fin = 474.717 uV 11:19:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 522.987 uVs 11:19:37 I2Y Average and RMS of Measurements VT = -509.512 +- 2.557 uVs I2Y = -46.875 +- 0.235 uTm^2 11:19:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:52 Integrated Voltage Measurement... 11:20:01 Voltage Offset Correction: v_off_ini = 468.705 uV, v_off_fin = 466.664 uV 11:20:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.770 uVs 11:20:01 Integrated Voltage Measurement... 11:20:10 Voltage Offset Correction: v_off_ini = 482.387 uV, v_off_fin = 469.569 uV 11:20:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.863 uVs 11:20:10 Integrated Voltage Measurement... 11:20:19 Voltage Offset Correction: v_off_ini = 476.405 uV, v_off_fin = 474.471 uV 11:20:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.389 uVs 11:20:19 Integrated Voltage Measurement... 11:20:28 Voltage Offset Correction: v_off_ini = 487.538 uV, v_off_fin = 483.604 uV 11:20:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.694 uVs 11:20:28 Integrated Voltage Measurement... 11:20:37 Voltage Offset Correction: v_off_ini = 477.078 uV, v_off_fin = 477.902 uV 11:20:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.482 uVs 11:20:37 Integrated Voltage Measurement... 11:20:46 Voltage Offset Correction: v_off_ini = 465.595 uV, v_off_fin = 475.721 uV 11:20:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.578 uVs 11:20:50 I1X Average and RMS of Measurements VT = -99.463 +- 8.419 uVs I1X = 19.893 +- 1.684 uTm 11:20:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:57 Integrated Voltage Measurement... 11:21:06 Voltage Offset Correction: v_off_ini = 471.534 uV, v_off_fin = 461.343 uV 11:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.217 uVs 11:21:06 Integrated Voltage Measurement... 11:21:15 Voltage Offset Correction: v_off_ini = 464.660 uV, v_off_fin = 470.296 uV 11:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.267 uVs 11:21:15 Integrated Voltage Measurement... 11:21:24 Voltage Offset Correction: v_off_ini = 465.207 uV, v_off_fin = 465.207 uV 11:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.223 uVs 11:21:24 Integrated Voltage Measurement... 11:21:33 Voltage Offset Correction: v_off_ini = 464.171 uV, v_off_fin = 480.308 uV 11:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.340 uVs 11:21:33 Integrated Voltage Measurement... 11:21:41 Voltage Offset Correction: v_off_ini = 466.385 uV, v_off_fin = 458.368 uV 11:21:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.052 uVs 11:21:42 Integrated Voltage Measurement... 11:21:50 Voltage Offset Correction: v_off_ini = 467.707 uV, v_off_fin = 476.895 uV 11:21:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.692 uVs 11:21:55 I1Y Average and RMS of Measurements VT = -200.799 +- 2.813 uVs I1Y = -40.157 +- 0.563 uTm 11:22:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:02 Integrated Voltage Measurement... 11:22:11 Voltage Offset Correction: v_off_ini = 469.781 uV, v_off_fin = 474.356 uV 11:22:11 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -70.596 uVs 11:22:11 Integrated Voltage Measurement... 11:22:20 Voltage Offset Correction: v_off_ini = 493.879 uV, v_off_fin = 499.248 uV 11:22:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.585 uVs 11:22:20 Integrated Voltage Measurement... 11:22:29 Voltage Offset Correction: v_off_ini = 500.584 uV, v_off_fin = 474.514 uV 11:22:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.060 uVs 11:22:29 Integrated Voltage Measurement... 11:22:38 Voltage Offset Correction: v_off_ini = 489.958 uV, v_off_fin = 483.413 uV 11:22:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.087 uVs 11:22:38 Integrated Voltage Measurement... 11:22:47 Voltage Offset Correction: v_off_ini = 480.613 uV, v_off_fin = 473.506 uV 11:22:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.211 uVs 11:22:47 Integrated Voltage Measurement... 11:22:56 Voltage Offset Correction: v_off_ini = 476.828 uV, v_off_fin = 487.528 uV 11:22:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.108 uVs 11:22:59 I2X Average and RMS of Measurements VT = -64.441 +- 4.159 uVs I2X = 5.928 +- 0.383 uTm^2 11:23:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:07 Integrated Voltage Measurement... 11:23:16 Voltage Offset Correction: v_off_ini = 467.872 uV, v_off_fin = 475.753 uV 11:23:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.417 uVs 11:23:16 Integrated Voltage Measurement... 11:23:25 Voltage Offset Correction: v_off_ini = 486.482 uV, v_off_fin = 480.770 uV 11:23:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.349 uVs 11:23:25 Integrated Voltage Measurement... 11:23:34 Voltage Offset Correction: v_off_ini = 476.555 uV, v_off_fin = 481.471 uV 11:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.273 uVs 11:23:34 Integrated Voltage Measurement... 11:23:43 Voltage Offset Correction: v_off_ini = 460.718 uV, v_off_fin = 489.028 uV 11:23:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 509.147 uVs 11:23:43 Integrated Voltage Measurement... 11:23:52 Voltage Offset Correction: v_off_ini = 479.379 uV, v_off_fin = 490.197 uV 11:23:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.901 uVs 11:23:52 Integrated Voltage Measurement... 11:24:01 Voltage Offset Correction: v_off_ini = 500.205 uV, v_off_fin = 488.457 uV 11:24:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.949 uVs 11:24:03 I2Y Average and RMS of Measurements VT = -504.339 +- 3.470 uVs I2Y = -46.399 +- 0.319 uTm^2 11:24:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:18 Integrated Voltage Measurement... 11:24:27 Voltage Offset Correction: v_off_ini = 497.882 uV, v_off_fin = 472.691 uV 11:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.206 uVs 11:24:27 Integrated Voltage Measurement... 11:24:36 Voltage Offset Correction: v_off_ini = 497.156 uV, v_off_fin = 499.521 uV 11:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.817 uVs 11:24:36 Integrated Voltage Measurement... 11:24:45 Voltage Offset Correction: v_off_ini = 504.980 uV, v_off_fin = 484.142 uV 11:24:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.979 uVs 11:24:45 Integrated Voltage Measurement... 11:24:54 Voltage Offset Correction: v_off_ini = 484.368 uV, v_off_fin = 499.607 uV 11:24:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.287 uVs 11:24:54 Integrated Voltage Measurement... 11:25:03 Voltage Offset Correction: v_off_ini = 487.044 uV, v_off_fin = 486.068 uV 11:25:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.044 uVs 11:25:03 Integrated Voltage Measurement... 11:25:12 Voltage Offset Correction: v_off_ini = 484.603 uV, v_off_fin = 489.117 uV 11:25:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.634 uVs 11:25:16 I1X Average and RMS of Measurements VT = -105.828 +- 6.942 uVs I1X = 21.166 +- 1.389 uTm 11:25:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:23 Integrated Voltage Measurement... 11:25:32 Voltage Offset Correction: v_off_ini = 474.221 uV, v_off_fin = 475.289 uV 11:25:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -199.138 uVs 11:25:32 Integrated Voltage Measurement... 11:25:41 Voltage Offset Correction: v_off_ini = 479.638 uV, v_off_fin = 497.763 uV 11:25:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.915 uVs 11:25:41 Integrated Voltage Measurement... 11:25:50 Voltage Offset Correction: v_off_ini = 487.181 uV, v_off_fin = 462.793 uV 11:25:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -202.871 uVs 11:25:50 Integrated Voltage Measurement... 11:25:59 Voltage Offset Correction: v_off_ini = 472.305 uV, v_off_fin = 477.790 uV 11:25:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 205.958 uVs 11:25:59 Integrated Voltage Measurement... 11:26:08 Voltage Offset Correction: v_off_ini = 482.136 uV, v_off_fin = 492.328 uV 11:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -202.915 uVs 11:26:08 Integrated Voltage Measurement... 11:26:17 Voltage Offset Correction: v_off_ini = 495.004 uV, v_off_fin = 514.428 uV 11:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.314 uVs 11:26:21 I1Y Average and RMS of Measurements VT = -202.519 +- 2.141 uVs I1Y = -40.498 +- 0.424 uTm 11:26:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:29 Integrated Voltage Measurement... 11:26:38 Voltage Offset Correction: v_off_ini = 488.061 uV, v_off_fin = 474.142 uV 11:26:38 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -89.713 uVs 11:26:38 Integrated Voltage Measurement... 11:26:47 Voltage Offset Correction: v_off_ini = 477.926 uV, v_off_fin = 492.149 uV 11:26:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.330 uVs 11:26:47 Integrated Voltage Measurement... 11:26:56 Voltage Offset Correction: v_off_ini = 472.550 uV, v_off_fin = 463.995 uV 11:26:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.454 uVs 11:26:56 Integrated Voltage Measurement... 11:27:05 Voltage Offset Correction: v_off_ini = 472.305 uV, v_off_fin = 490.258 uV 11:27:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.277 uVs 11:27:05 Integrated Voltage Measurement... 11:27:14 Voltage Offset Correction: v_off_ini = 471.146 uV, v_off_fin = 461.050 uV 11:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.961 uVs 11:27:14 Integrated Voltage Measurement... 11:27:23 Voltage Offset Correction: v_off_ini = 472.226 uV, v_off_fin = 491.015 uV 11:27:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.892 uVs 11:27:25 I2X Average and RMS of Measurements VT = -85.438 +- 4.654 uVs I2X = 7.860 +- 0.428 uTm^2 11:27:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:33 Integrated Voltage Measurement... 11:27:42 Voltage Offset Correction: v_off_ini = 473.139 uV, v_off_fin = 477.400 uV 11:27:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -502.364 uVs 11:27:42 Integrated Voltage Measurement... 11:27:51 Voltage Offset Correction: v_off_ini = 473.524 uV, v_off_fin = 476.838 uV 11:27:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 501.504 uVs 11:27:51 Integrated Voltage Measurement... 11:28:00 Voltage Offset Correction: v_off_ini = 480.522 uV, v_off_fin = 485.115 uV 11:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.988 uVs 11:28:00 Integrated Voltage Measurement... 11:28:09 Voltage Offset Correction: v_off_ini = 481.316 uV, v_off_fin = 480.547 uV 11:28:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.788 uVs 11:28:09 Integrated Voltage Measurement... 11:28:18 Voltage Offset Correction: v_off_ini = 482.711 uV, v_off_fin = 491.648 uV 11:28:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.425 uVs 11:28:18 Integrated Voltage Measurement... 11:28:27 Voltage Offset Correction: v_off_ini = 470.286 uV, v_off_fin = 481.360 uV 11:28:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 505.477 uVs 11:28:29 I2Y Average and RMS of Measurements VT = -496.091 +- 7.924 uVs I2Y = -45.640 +- 0.729 uTm^2 11:28:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:44 Integrated Voltage Measurement... 11:28:53 Voltage Offset Correction: v_off_ini = 478.995 uV, v_off_fin = 476.491 uV 11:28:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.885 uVs 11:28:53 Integrated Voltage Measurement... 11:29:02 Voltage Offset Correction: v_off_ini = 483.997 uV, v_off_fin = 487.106 uV 11:29:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.742 uVs 11:29:02 Integrated Voltage Measurement... 11:29:11 Voltage Offset Correction: v_off_ini = 467.808 uV, v_off_fin = 474.607 uV 11:29:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.509 uVs 11:29:11 Integrated Voltage Measurement... 11:29:20 Voltage Offset Correction: v_off_ini = 487.395 uV, v_off_fin = 495.886 uV 11:29:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.527 uVs 11:29:20 Integrated Voltage Measurement... 11:29:29 Voltage Offset Correction: v_off_ini = 489.988 uV, v_off_fin = 475.792 uV 11:29:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.720 uVs 11:29:29 Integrated Voltage Measurement... 11:29:38 Voltage Offset Correction: v_off_ini = 482.472 uV, v_off_fin = 484.082 uV 11:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.178 uVs 11:29:42 I1X Average and RMS of Measurements VT = -106.427 +- 3.022 uVs I1X = 21.286 +- 0.604 uTm 11:29:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:49 Integrated Voltage Measurement... 11:29:58 Voltage Offset Correction: v_off_ini = 480.292 uV, v_off_fin = 478.347 uV 11:29:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.656 uVs 11:29:58 Integrated Voltage Measurement... 11:30:07 Voltage Offset Correction: v_off_ini = 492.665 uV, v_off_fin = 487.398 uV 11:30:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 205.628 uVs 11:30:07 Integrated Voltage Measurement... 11:30:16 Voltage Offset Correction: v_off_ini = 478.397 uV, v_off_fin = 473.000 uV 11:30:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.852 uVs 11:30:16 Integrated Voltage Measurement... 11:30:25 Voltage Offset Correction: v_off_ini = 484.994 uV, v_off_fin = 501.400 uV 11:30:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 191.630 uVs 11:30:25 Integrated Voltage Measurement... 11:30:34 Voltage Offset Correction: v_off_ini = 493.909 uV, v_off_fin = 494.648 uV 11:30:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.628 uVs 11:30:34 Integrated Voltage Measurement... 11:30:43 Voltage Offset Correction: v_off_ini = 482.331 uV, v_off_fin = 516.360 uV 11:30:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 195.992 uVs 11:30:47 I1Y Average and RMS of Measurements VT = -200.564 +- 5.497 uVs I1Y = -40.108 +- 1.100 uTm 11:30:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:55 Integrated Voltage Measurement... 11:31:04 Voltage Offset Correction: v_off_ini = 500.628 uV, v_off_fin = 486.514 uV 11:31:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -101.718 uVs 11:31:04 Integrated Voltage Measurement... 11:31:13 Voltage Offset Correction: v_off_ini = 502.523 uV, v_off_fin = 516.389 uV 11:31:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.225 uVs 11:31:13 Integrated Voltage Measurement... 11:31:22 Voltage Offset Correction: v_off_ini = 500.204 uV, v_off_fin = 496.220 uV 11:31:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.688 uVs 11:31:22 Integrated Voltage Measurement... 11:31:31 Voltage Offset Correction: v_off_ini = 498.752 uV, v_off_fin = 498.425 uV 11:31:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.649 uVs 11:31:31 Integrated Voltage Measurement... 11:31:40 Voltage Offset Correction: v_off_ini = 480.020 uV, v_off_fin = 474.461 uV 11:31:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.140 uVs 11:31:40 Integrated Voltage Measurement... 11:31:49 Voltage Offset Correction: v_off_ini = 486.325 uV, v_off_fin = 487.362 uV 11:31:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.033 uVs 11:31:51 I2X Average and RMS of Measurements VT = -88.575 +- 4.714 uVs I2X = 8.149 +- 0.434 uTm^2 11:31:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:59 Integrated Voltage Measurement... 11:32:08 Voltage Offset Correction: v_off_ini = 485.150 uV, v_off_fin = 473.231 uV 11:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.830 uVs 11:32:08 Integrated Voltage Measurement... 11:32:17 Voltage Offset Correction: v_off_ini = 478.801 uV, v_off_fin = 482.769 uV 11:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.087 uVs 11:32:17 Integrated Voltage Measurement... 11:32:26 Voltage Offset Correction: v_off_ini = 473.857 uV, v_off_fin = 472.207 uV 11:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.252 uVs 11:32:26 Integrated Voltage Measurement... 11:32:35 Voltage Offset Correction: v_off_ini = 475.136 uV, v_off_fin = 475.833 uV 11:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 497.517 uVs 11:32:35 Integrated Voltage Measurement... 11:32:44 Voltage Offset Correction: v_off_ini = 482.491 uV, v_off_fin = 483.520 uV 11:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -504.217 uVs 11:32:44 Integrated Voltage Measurement... 11:32:53 Voltage Offset Correction: v_off_ini = 482.546 uV, v_off_fin = 490.747 uV 11:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.595 uVs 11:32:55 I2Y Average and RMS of Measurements VT = -496.583 +- 4.898 uVs I2Y = -45.686 +- 0.451 uTm^2 11:33:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:10 Integrated Voltage Measurement... 11:33:19 Voltage Offset Correction: v_off_ini = 482.153 uV, v_off_fin = 487.326 uV 11:33:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.032 uVs 11:33:19 Integrated Voltage Measurement... 11:33:28 Voltage Offset Correction: v_off_ini = 486.256 uV, v_off_fin = 494.342 uV 11:33:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.228 uVs 11:33:28 Integrated Voltage Measurement... 11:33:37 Voltage Offset Correction: v_off_ini = 485.786 uV, v_off_fin = 489.839 uV 11:33:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.488 uVs 11:33:37 Integrated Voltage Measurement... 11:33:46 Voltage Offset Correction: v_off_ini = 486.816 uV, v_off_fin = 492.322 uV 11:33:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.773 uVs 11:33:46 Integrated Voltage Measurement... 11:33:55 Voltage Offset Correction: v_off_ini = 474.816 uV, v_off_fin = 492.703 uV 11:33:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.501 uVs 11:33:55 Integrated Voltage Measurement... 11:34:04 Voltage Offset Correction: v_off_ini = 492.577 uV, v_off_fin = 500.493 uV 11:34:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.728 uVs 11:34:09 I1X Average and RMS of Measurements VT = -113.792 +- 4.087 uVs I1X = 22.758 +- 0.817 uTm 11:34:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:34:15 Integrated Voltage Measurement... 11:34:24 Voltage Offset Correction: v_off_ini = 495.586 uV, v_off_fin = 487.384 uV 11:34:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.413 uVs 11:34:24 Integrated Voltage Measurement... 11:34:33 Voltage Offset Correction: v_off_ini = 498.661 uV, v_off_fin = 509.417 uV 11:34:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 214.828 uVs 11:34:33 Integrated Voltage Measurement... 11:34:42 Voltage Offset Correction: v_off_ini = 492.021 uV, v_off_fin = 492.309 uV 11:34:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.885 uVs 11:34:42 Integrated Voltage Measurement... 11:34:51 Voltage Offset Correction: v_off_ini = 500.154 uV, v_off_fin = 508.194 uV 11:34:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 205.454 uVs 11:34:51 Integrated Voltage Measurement... 11:35:00 Voltage Offset Correction: v_off_ini = 499.516 uV, v_off_fin = 477.657 uV 11:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.374 uVs 11:35:00 Integrated Voltage Measurement... 11:35:09 Voltage Offset Correction: v_off_ini = 490.687 uV, v_off_fin = 508.879 uV 11:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 204.482 uVs 11:35:14 I1Y Average and RMS of Measurements VT = -206.073 +- 4.721 uVs I1Y = -41.208 +- 0.944 uTm 11:35:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:21 Integrated Voltage Measurement... 11:35:30 Voltage Offset Correction: v_off_ini = 514.869 uV, v_off_fin = 502.033 uV 11:35:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.140 uVs 11:35:30 Integrated Voltage Measurement... 11:35:39 Voltage Offset Correction: v_off_ini = 515.047 uV, v_off_fin = 534.183 uV 11:35:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.237 uVs 11:35:39 Integrated Voltage Measurement... 11:35:48 Voltage Offset Correction: v_off_ini = 502.371 uV, v_off_fin = 501.103 uV 11:35:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.523 uVs 11:35:48 Integrated Voltage Measurement... 11:35:57 Voltage Offset Correction: v_off_ini = 512.428 uV, v_off_fin = 514.678 uV 11:35:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.933 uVs 11:35:57 Integrated Voltage Measurement... 11:36:06 Voltage Offset Correction: v_off_ini = 503.631 uV, v_off_fin = 501.326 uV 11:36:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.044 uVs 11:36:06 Integrated Voltage Measurement... 11:36:15 Voltage Offset Correction: v_off_ini = 506.282 uV, v_off_fin = 518.559 uV 11:36:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.147 uVs 11:36:18 I2X Average and RMS of Measurements VT = -91.004 +- 1.882 uVs I2X = 8.373 +- 0.173 uTm^2 11:36:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:26 Integrated Voltage Measurement... 11:36:34 Voltage Offset Correction: v_off_ini = 526.623 uV, v_off_fin = 510.101 uV 11:36:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.030 uVs 11:36:35 Integrated Voltage Measurement... 11:36:44 Voltage Offset Correction: v_off_ini = 513.342 uV, v_off_fin = 516.658 uV 11:36:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.607 uVs 11:36:44 Integrated Voltage Measurement... 11:36:53 Voltage Offset Correction: v_off_ini = 500.504 uV, v_off_fin = 490.383 uV 11:36:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -502.146 uVs 11:36:53 Integrated Voltage Measurement... 11:37:02 Voltage Offset Correction: v_off_ini = 491.601 uV, v_off_fin = 519.141 uV 11:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 488.354 uVs 11:37:02 Integrated Voltage Measurement... 11:37:11 Voltage Offset Correction: v_off_ini = 508.918 uV, v_off_fin = 500.413 uV 11:37:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -495.093 uVs 11:37:11 Integrated Voltage Measurement... 11:37:20 Voltage Offset Correction: v_off_ini = 511.584 uV, v_off_fin = 522.007 uV 11:37:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 486.962 uVs 11:37:22 I2Y Average and RMS of Measurements VT = -491.699 +- 2.668 uVs I2Y = -45.238 +- 0.246 uTm^2 11:37:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:37 Integrated Voltage Measurement... 11:37:46 Voltage Offset Correction: v_off_ini = 513.030 uV, v_off_fin = 514.639 uV 11:37:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -137.663 uVs 11:37:46 Integrated Voltage Measurement... 11:37:55 Voltage Offset Correction: v_off_ini = 504.487 uV, v_off_fin = 502.328 uV 11:37:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.584 uVs 11:37:55 Integrated Voltage Measurement... 11:38:04 Voltage Offset Correction: v_off_ini = 503.114 uV, v_off_fin = 497.251 uV 11:38:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.698 uVs 11:38:04 Integrated Voltage Measurement... 11:38:13 Voltage Offset Correction: v_off_ini = 500.002 uV, v_off_fin = 521.039 uV 11:38:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.168 uVs 11:38:13 Integrated Voltage Measurement... 11:38:22 Voltage Offset Correction: v_off_ini = 512.150 uV, v_off_fin = 512.754 uV 11:38:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.228 uVs 11:38:23 Integrated Voltage Measurement... 11:38:32 Voltage Offset Correction: v_off_ini = 523.722 uV, v_off_fin = 536.860 uV 11:38:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.400 uVs 11:38:36 I1X Average and RMS of Measurements VT = -122.957 +- 8.750 uVs I1X = 24.594 +- 1.751 uTm 11:38:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:43 Integrated Voltage Measurement... 11:38:52 Voltage Offset Correction: v_off_ini = 518.441 uV, v_off_fin = 511.124 uV 11:38:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.782 uVs 11:38:52 Integrated Voltage Measurement... 11:39:01 Voltage Offset Correction: v_off_ini = 532.267 uV, v_off_fin = 543.660 uV 11:39:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 201.303 uVs 11:39:01 Integrated Voltage Measurement... 11:39:10 Voltage Offset Correction: v_off_ini = 537.945 uV, v_off_fin = 510.667 uV 11:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -204.987 uVs 11:39:10 Integrated Voltage Measurement... 11:39:19 Voltage Offset Correction: v_off_ini = 517.667 uV, v_off_fin = 543.780 uV 11:39:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 200.076 uVs 11:39:19 Integrated Voltage Measurement... 11:39:28 Voltage Offset Correction: v_off_ini = 533.391 uV, v_off_fin = 519.466 uV 11:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -215.169 uVs 11:39:28 Integrated Voltage Measurement... 11:39:37 Voltage Offset Correction: v_off_ini = 540.548 uV, v_off_fin = 549.560 uV 11:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 211.836 uVs 11:39:41 I1Y Average and RMS of Measurements VT = -205.525 +- 5.699 uVs I1Y = -41.098 +- 1.138 uTm 11:39:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:49 Integrated Voltage Measurement... 11:39:58 Voltage Offset Correction: v_off_ini = 539.573 uV, v_off_fin = 533.310 uV 11:39:58 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -103.135 uVs 11:39:58 Integrated Voltage Measurement... 11:40:07 Voltage Offset Correction: v_off_ini = 541.186 uV, v_off_fin = 549.719 uV 11:40:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.144 uVs 11:40:07 Integrated Voltage Measurement... 11:40:16 Voltage Offset Correction: v_off_ini = 537.052 uV, v_off_fin = 515.580 uV 11:40:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.435 uVs 11:40:16 Integrated Voltage Measurement... 11:40:25 Voltage Offset Correction: v_off_ini = 535.436 uV, v_off_fin = 559.906 uV 11:40:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.025 uVs 11:40:25 Integrated Voltage Measurement... 11:40:34 Voltage Offset Correction: v_off_ini = 532.077 uV, v_off_fin = 529.872 uV 11:40:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.627 uVs 11:40:34 Integrated Voltage Measurement... 11:40:43 Voltage Offset Correction: v_off_ini = 534.902 uV, v_off_fin = 538.247 uV 11:40:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.452 uVs 11:40:46 I2X Average and RMS of Measurements VT = -104.803 +- 7.280 uVs I2X = 9.642 +- 0.670 uTm^2 11:40:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:53 Integrated Voltage Measurement... 11:41:02 Voltage Offset Correction: v_off_ini = 539.681 uV, v_off_fin = 536.055 uV 11:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -489.016 uVs 11:41:02 Integrated Voltage Measurement... 11:41:11 Voltage Offset Correction: v_off_ini = 536.022 uV, v_off_fin = 537.764 uV 11:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 500.230 uVs 11:41:11 Integrated Voltage Measurement... 11:41:20 Voltage Offset Correction: v_off_ini = 546.930 uV, v_off_fin = 555.937 uV 11:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.142 uVs 11:41:20 Integrated Voltage Measurement... 11:41:29 Voltage Offset Correction: v_off_ini = 536.526 uV, v_off_fin = 545.711 uV 11:41:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 485.812 uVs 11:41:29 Integrated Voltage Measurement... 11:41:38 Voltage Offset Correction: v_off_ini = 545.452 uV, v_off_fin = 550.199 uV 11:41:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.236 uVs 11:41:38 Integrated Voltage Measurement... 11:41:47 Voltage Offset Correction: v_off_ini = 553.573 uV, v_off_fin = 547.113 uV 11:41:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.416 uVs 11:41:50 I2Y Average and RMS of Measurements VT = -488.642 +- 4.366 uVs I2Y = -44.955 +- 0.402 uTm^2 11:42:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:05 Integrated Voltage Measurement... 11:42:14 Voltage Offset Correction: v_off_ini = 536.070 uV, v_off_fin = 541.329 uV 11:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.290 uVs 11:42:14 Integrated Voltage Measurement... 11:42:23 Voltage Offset Correction: v_off_ini = 550.814 uV, v_off_fin = 548.021 uV 11:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.744 uVs 11:42:23 Integrated Voltage Measurement... 11:42:32 Voltage Offset Correction: v_off_ini = 553.273 uV, v_off_fin = 536.341 uV 11:42:32 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -141.166 uVs 11:42:32 Integrated Voltage Measurement... 11:42:41 Voltage Offset Correction: v_off_ini = 542.921 uV, v_off_fin = 537.643 uV 11:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 124.223 uVs 11:42:41 Integrated Voltage Measurement... 11:42:50 Voltage Offset Correction: v_off_ini = 547.634 uV, v_off_fin = 547.458 uV 11:42:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -117.592 uVs 11:42:50 Integrated Voltage Measurement... 11:42:59 Voltage Offset Correction: v_off_ini = 559.617 uV, v_off_fin = 549.289 uV 11:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 122.323 uVs 11:43:03 I1X Average and RMS of Measurements VT = -125.223 +- 5.429 uVs I1X = 25.049 +- 1.087 uTm 11:43:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:43:10 Integrated Voltage Measurement... 11:43:19 Voltage Offset Correction: v_off_ini = 540.954 uV, v_off_fin = 547.111 uV 11:43:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.394 uVs 11:43:19 Integrated Voltage Measurement... 11:43:28 Voltage Offset Correction: v_off_ini = 558.390 uV, v_off_fin = 566.979 uV 11:43:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 217.766 uVs 11:43:28 Integrated Voltage Measurement... 11:43:37 Voltage Offset Correction: v_off_ini = 555.939 uV, v_off_fin = 541.284 uV 11:43:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -198.973 uVs 11:43:37 Integrated Voltage Measurement... 11:43:46 Voltage Offset Correction: v_off_ini = 555.353 uV, v_off_fin = 560.565 uV 11:43:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.816 uVs 11:43:47 Integrated Voltage Measurement... 11:43:56 Voltage Offset Correction: v_off_ini = 559.025 uV, v_off_fin = 549.251 uV 11:43:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.885 uVs 11:43:56 Integrated Voltage Measurement... 11:44:05 Voltage Offset Correction: v_off_ini = 559.080 uV, v_off_fin = 568.345 uV 11:44:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.038 uVs 11:44:09 I1Y Average and RMS of Measurements VT = -209.479 +- 2.836 uVs I1Y = -41.891 +- 0.568 uTm 11:44:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:17 Integrated Voltage Measurement... 11:44:26 Voltage Offset Correction: v_off_ini = 560.364 uV, v_off_fin = 551.095 uV 11:44:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -95.760 uVs 11:44:26 Integrated Voltage Measurement... 11:44:35 Voltage Offset Correction: v_off_ini = 559.916 uV, v_off_fin = 568.374 uV 11:44:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.994 uVs 11:44:35 Integrated Voltage Measurement... 11:44:44 Voltage Offset Correction: v_off_ini = 585.692 uV, v_off_fin = 582.546 uV 11:44:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.491 uVs 11:44:44 Integrated Voltage Measurement... 11:44:53 Voltage Offset Correction: v_off_ini = 571.460 uV, v_off_fin = 578.857 uV 11:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.300 uVs 11:44:53 Integrated Voltage Measurement... 11:45:02 Voltage Offset Correction: v_off_ini = 560.514 uV, v_off_fin = 551.077 uV 11:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.647 uVs 11:45:02 Integrated Voltage Measurement... 11:45:11 Voltage Offset Correction: v_off_ini = 558.722 uV, v_off_fin = 563.700 uV 11:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.384 uVs 11:45:13 I2X Average and RMS of Measurements VT = -111.430 +- 11.295 uVs I2X = 10.251 +- 1.039 uTm^2 11:45:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:21 Integrated Voltage Measurement... 11:45:30 Voltage Offset Correction: v_off_ini = 557.139 uV, v_off_fin = 564.039 uV 11:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.544 uVs 11:45:30 Integrated Voltage Measurement... 11:45:39 Voltage Offset Correction: v_off_ini = 567.880 uV, v_off_fin = 554.374 uV 11:45:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.430 uVs 11:45:39 Integrated Voltage Measurement... 11:45:48 Voltage Offset Correction: v_off_ini = 562.230 uV, v_off_fin = 551.096 uV 11:45:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -493.019 uVs 11:45:48 Integrated Voltage Measurement... 11:45:57 Voltage Offset Correction: v_off_ini = 556.371 uV, v_off_fin = 549.686 uV 11:45:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 477.559 uVs 11:45:57 Integrated Voltage Measurement... 11:46:06 Voltage Offset Correction: v_off_ini = 556.151 uV, v_off_fin = 561.282 uV 11:46:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -469.748 uVs 11:46:06 Integrated Voltage Measurement... 11:46:15 Voltage Offset Correction: v_off_ini = 562.299 uV, v_off_fin = 558.283 uV 11:46:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 477.247 uVs 11:46:18 I2Y Average and RMS of Measurements VT = -477.591 +- 5.447 uVs I2Y = -43.941 +- 0.503 uTm^2 11:46:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:33 Integrated Voltage Measurement... 11:46:42 Voltage Offset Correction: v_off_ini = 557.156 uV, v_off_fin = 546.851 uV 11:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.411 uVs 11:46:42 Integrated Voltage Measurement... 11:46:51 Voltage Offset Correction: v_off_ini = 528.684 uV, v_off_fin = 549.397 uV 11:46:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.540 uVs 11:46:51 Integrated Voltage Measurement... 11:47:00 Voltage Offset Correction: v_off_ini = 552.261 uV, v_off_fin = 554.843 uV 11:47:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -136.216 uVs 11:47:00 Integrated Voltage Measurement... 11:47:09 Voltage Offset Correction: v_off_ini = 554.995 uV, v_off_fin = 559.604 uV 11:47:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.221 uVs 11:47:09 Integrated Voltage Measurement... 11:47:18 Voltage Offset Correction: v_off_ini = 564.045 uV, v_off_fin = 561.429 uV 11:47:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.429 uVs 11:47:18 Integrated Voltage Measurement... 11:47:27 Voltage Offset Correction: v_off_ini = 555.307 uV, v_off_fin = 569.606 uV 11:47:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.499 uVs 11:47:31 I1X Average and RMS of Measurements VT = -141.553 +- 14.936 uVs I1X = 28.312 +- 2.988 uTm 11:47:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:38 Integrated Voltage Measurement... 11:47:47 Voltage Offset Correction: v_off_ini = 553.754 uV, v_off_fin = 540.355 uV 11:47:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.928 uVs 11:47:47 Integrated Voltage Measurement... 11:47:56 Voltage Offset Correction: v_off_ini = 552.877 uV, v_off_fin = 584.815 uV 11:47:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.781 uVs 11:47:56 Integrated Voltage Measurement... 11:48:05 Voltage Offset Correction: v_off_ini = 551.988 uV, v_off_fin = 536.881 uV 11:48:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.316 uVs 11:48:05 Integrated Voltage Measurement... 11:48:14 Voltage Offset Correction: v_off_ini = 565.065 uV, v_off_fin = 575.457 uV 11:48:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.780 uVs 11:48:14 Integrated Voltage Measurement... 11:48:23 Voltage Offset Correction: v_off_ini = 551.679 uV, v_off_fin = 548.292 uV 11:48:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.051 uVs 11:48:23 Integrated Voltage Measurement... 11:48:32 Voltage Offset Correction: v_off_ini = 565.337 uV, v_off_fin = 586.749 uV 11:48:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.558 uVs 11:48:36 I1Y Average and RMS of Measurements VT = -206.736 +- 5.997 uVs I1Y = -41.344 +- 1.198 uTm 11:48:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:44 Integrated Voltage Measurement... 11:48:53 Voltage Offset Correction: v_off_ini = 567.759 uV, v_off_fin = 564.372 uV 11:48:53 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -108.288 uVs 11:48:53 Integrated Voltage Measurement... 11:49:02 Voltage Offset Correction: v_off_ini = 579.802 uV, v_off_fin = 584.746 uV 11:49:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.520 uVs 11:49:02 Integrated Voltage Measurement... 11:49:11 Voltage Offset Correction: v_off_ini = 579.842 uV, v_off_fin = 577.023 uV 11:49:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.614 uVs 11:49:11 Integrated Voltage Measurement... 11:49:20 Voltage Offset Correction: v_off_ini = 580.122 uV, v_off_fin = 600.563 uV 11:49:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.012 uVs 11:49:20 Integrated Voltage Measurement... 11:49:29 Voltage Offset Correction: v_off_ini = 583.135 uV, v_off_fin = 577.198 uV 11:49:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.475 uVs 11:49:29 Integrated Voltage Measurement... 11:49:38 Voltage Offset Correction: v_off_ini = 593.830 uV, v_off_fin = 603.351 uV 11:49:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.743 uVs 11:49:41 I2X Average and RMS of Measurements VT = -113.775 +- 4.030 uVs I2X = 10.467 +- 0.371 uTm^2 11:49:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:48 Integrated Voltage Measurement... 11:49:57 Voltage Offset Correction: v_off_ini = 598.018 uV, v_off_fin = 597.972 uV 11:49:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -470.547 uVs 11:49:57 Integrated Voltage Measurement... 11:50:06 Voltage Offset Correction: v_off_ini = 583.713 uV, v_off_fin = 592.271 uV 11:50:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 467.006 uVs 11:50:06 Integrated Voltage Measurement... 11:50:15 Voltage Offset Correction: v_off_ini = 579.795 uV, v_off_fin = 579.885 uV 11:50:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.921 uVs 11:50:16 Integrated Voltage Measurement... 11:50:25 Voltage Offset Correction: v_off_ini = 580.405 uV, v_off_fin = 591.943 uV 11:50:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.710 uVs 11:50:25 Integrated Voltage Measurement... 11:50:34 Voltage Offset Correction: v_off_ini = 593.528 uV, v_off_fin = 581.548 uV 11:50:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.579 uVs 11:50:34 Integrated Voltage Measurement... 11:50:43 Voltage Offset Correction: v_off_ini = 585.739 uV, v_off_fin = 589.502 uV 11:50:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 482.071 uVs 11:50:45 I2Y Average and RMS of Measurements VT = -473.972 +- 8.037 uVs I2Y = -43.606 +- 0.740 uTm^2 11:50:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:00 Integrated Voltage Measurement... 11:51:09 Voltage Offset Correction: v_off_ini = 602.585 uV, v_off_fin = 619.025 uV 11:51:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -140.041 uVs 11:51:09 Integrated Voltage Measurement... 11:51:18 Voltage Offset Correction: v_off_ini = 605.458 uV, v_off_fin = 602.933 uV 11:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.371 uVs 11:51:18 Integrated Voltage Measurement... 11:51:27 Voltage Offset Correction: v_off_ini = 602.333 uV, v_off_fin = 590.566 uV 11:51:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.794 uVs 11:51:27 Integrated Voltage Measurement... 11:51:36 Voltage Offset Correction: v_off_ini = 595.640 uV, v_off_fin = 588.902 uV 11:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.013 uVs 11:51:36 Integrated Voltage Measurement... 11:51:45 Voltage Offset Correction: v_off_ini = 604.025 uV, v_off_fin = 587.162 uV 11:51:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.681 uVs 11:51:45 Integrated Voltage Measurement... 11:51:54 Voltage Offset Correction: v_off_ini = 602.902 uV, v_off_fin = 605.690 uV 11:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.427 uVs 11:51:59 I1X Average and RMS of Measurements VT = -131.054 +- 3.738 uVs I1X = 26.212 +- 0.748 uTm 11:52:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:52:06 Integrated Voltage Measurement... 11:52:14 Voltage Offset Correction: v_off_ini = 590.086 uV, v_off_fin = 581.765 uV 11:52:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.404 uVs 11:52:15 Integrated Voltage Measurement... 11:52:23 Voltage Offset Correction: v_off_ini = 590.817 uV, v_off_fin = 600.641 uV 11:52:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.064 uVs 11:52:24 Integrated Voltage Measurement... 11:52:32 Voltage Offset Correction: v_off_ini = 587.122 uV, v_off_fin = 571.640 uV 11:52:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.088 uVs 11:52:33 Integrated Voltage Measurement... 11:52:41 Voltage Offset Correction: v_off_ini = 589.634 uV, v_off_fin = 597.011 uV 11:52:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.718 uVs 11:52:42 Integrated Voltage Measurement... 11:52:50 Voltage Offset Correction: v_off_ini = 600.164 uV, v_off_fin = 590.783 uV 11:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.605 uVs 11:52:51 Integrated Voltage Measurement... 11:52:59 Voltage Offset Correction: v_off_ini = 603.592 uV, v_off_fin = 615.371 uV 11:53:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.622 uVs 11:53:04 I1Y Average and RMS of Measurements VT = -208.917 +- 3.033 uVs I1Y = -41.781 +- 0.608 uTm 11:53:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:11 Integrated Voltage Measurement... 11:53:20 Voltage Offset Correction: v_off_ini = 591.240 uV, v_off_fin = 594.859 uV 11:53:20 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -101.603 uVs 11:53:21 Integrated Voltage Measurement... 11:53:30 Voltage Offset Correction: v_off_ini = 603.675 uV, v_off_fin = 617.551 uV 11:53:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.379 uVs 11:53:30 Integrated Voltage Measurement... 11:53:39 Voltage Offset Correction: v_off_ini = 602.061 uV, v_off_fin = 582.640 uV 11:53:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.210 uVs 11:53:39 Integrated Voltage Measurement... 11:53:48 Voltage Offset Correction: v_off_ini = 605.370 uV, v_off_fin = 619.377 uV 11:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.006 uVs 11:53:48 Integrated Voltage Measurement... 11:53:57 Voltage Offset Correction: v_off_ini = 613.375 uV, v_off_fin = 607.127 uV 11:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.783 uVs 11:53:57 Integrated Voltage Measurement... 11:54:06 Voltage Offset Correction: v_off_ini = 606.741 uV, v_off_fin = 623.768 uV 11:54:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.179 uVs 11:54:08 I2X Average and RMS of Measurements VT = -118.693 +- 8.071 uVs I2X = 10.919 +- 0.743 uTm^2 11:54:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:16 Integrated Voltage Measurement... 11:54:25 Voltage Offset Correction: v_off_ini = 615.605 uV, v_off_fin = 621.670 uV 11:54:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -466.114 uVs 11:54:25 Integrated Voltage Measurement... 11:54:34 Voltage Offset Correction: v_off_ini = 624.173 uV, v_off_fin = 626.169 uV 11:54:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.358 uVs 11:54:34 Integrated Voltage Measurement... 11:54:43 Voltage Offset Correction: v_off_ini = 620.300 uV, v_off_fin = 617.979 uV 11:54:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -455.067 uVs 11:54:43 Integrated Voltage Measurement... 11:54:52 Voltage Offset Correction: v_off_ini = 613.272 uV, v_off_fin = 627.973 uV 11:54:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.575 uVs 11:54:52 Integrated Voltage Measurement... 11:55:01 Voltage Offset Correction: v_off_ini = 607.365 uV, v_off_fin = 613.171 uV 11:55:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -474.159 uVs 11:55:01 Integrated Voltage Measurement... 11:55:10 Voltage Offset Correction: v_off_ini = 610.273 uV, v_off_fin = 621.214 uV 11:55:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 445.918 uVs 11:55:13 I2Y Average and RMS of Measurements VT = -459.365 +- 1.473 uVs I2Y = -42.262 +- 0.136 uTm^2 11:55:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:29 Integrated Voltage Measurement... 11:55:38 Voltage Offset Correction: v_off_ini = 628.113 uV, v_off_fin = 622.310 uV 11:55:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -136.882 uVs 11:55:38 Integrated Voltage Measurement... 11:55:47 Voltage Offset Correction: v_off_ini = 628.102 uV, v_off_fin = 644.049 uV 11:55:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.844 uVs 11:55:47 Integrated Voltage Measurement... 11:55:56 Voltage Offset Correction: v_off_ini = 623.450 uV, v_off_fin = 637.482 uV 11:55:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.093 uVs 11:55:56 Integrated Voltage Measurement... 11:56:05 Voltage Offset Correction: v_off_ini = 631.310 uV, v_off_fin = 635.650 uV 11:56:05 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 139.169 uVs 11:56:05 Integrated Voltage Measurement... 11:56:14 Voltage Offset Correction: v_off_ini = 625.828 uV, v_off_fin = 621.910 uV 11:56:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.457 uVs 11:56:14 Integrated Voltage Measurement... 11:56:23 Voltage Offset Correction: v_off_ini = 621.022 uV, v_off_fin = 623.870 uV 11:56:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.031 uVs 11:56:27 I1X Average and RMS of Measurements VT = -136.079 +- 5.016 uVs I1X = 27.217 +- 1.003 uTm 11:56:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:34 Integrated Voltage Measurement... 11:56:43 Voltage Offset Correction: v_off_ini = 603.440 uV, v_off_fin = 604.013 uV 11:56:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.212 uVs 11:56:43 Integrated Voltage Measurement... 11:56:52 Voltage Offset Correction: v_off_ini = 592.743 uV, v_off_fin = 605.299 uV 11:56:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.362 uVs 11:56:52 Integrated Voltage Measurement... 11:57:01 Voltage Offset Correction: v_off_ini = 608.391 uV, v_off_fin = 596.307 uV 11:57:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.342 uVs 11:57:01 Integrated Voltage Measurement... 11:57:10 Voltage Offset Correction: v_off_ini = 602.363 uV, v_off_fin = 625.660 uV 11:57:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.073 uVs 11:57:10 Integrated Voltage Measurement... 11:57:19 Voltage Offset Correction: v_off_ini = 606.336 uV, v_off_fin = 599.282 uV 11:57:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.685 uVs 11:57:19 Integrated Voltage Measurement... 11:57:28 Voltage Offset Correction: v_off_ini = 591.740 uV, v_off_fin = 619.449 uV 11:57:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.562 uVs 11:57:32 I1Y Average and RMS of Measurements VT = -202.873 +- 9.025 uVs I1Y = -40.571 +- 1.805 uTm 11:57:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:40 Integrated Voltage Measurement... 11:57:49 Voltage Offset Correction: v_off_ini = 612.276 uV, v_off_fin = 600.281 uV 11:57:49 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -144.004 uVs 11:57:49 Integrated Voltage Measurement... 11:57:58 Voltage Offset Correction: v_off_ini = 609.048 uV, v_off_fin = 618.529 uV 11:57:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.383 uVs 11:57:58 Integrated Voltage Measurement... 11:58:07 Voltage Offset Correction: v_off_ini = 608.158 uV, v_off_fin = 598.141 uV 11:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.869 uVs 11:58:07 Integrated Voltage Measurement... 11:58:16 Voltage Offset Correction: v_off_ini = 610.047 uV, v_off_fin = 628.373 uV 11:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.834 uVs 11:58:16 Integrated Voltage Measurement... 11:58:25 Voltage Offset Correction: v_off_ini = 594.029 uV, v_off_fin = 605.840 uV 11:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.246 uVs 11:58:25 Integrated Voltage Measurement... 11:58:34 Voltage Offset Correction: v_off_ini = 624.369 uV, v_off_fin = 627.801 uV 11:58:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.404 uVs 11:58:37 I2X Average and RMS of Measurements VT = -118.790 +- 7.720 uVs I2X = 10.929 +- 0.710 uTm^2 11:58:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:44 Integrated Voltage Measurement... 11:58:53 Voltage Offset Correction: v_off_ini = 632.419 uV, v_off_fin = 620.589 uV 11:58:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.180 uVs 11:58:53 Integrated Voltage Measurement... 11:59:02 Voltage Offset Correction: v_off_ini = 617.839 uV, v_off_fin = 613.946 uV 11:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.943 uVs 11:59:03 Integrated Voltage Measurement... 11:59:12 Voltage Offset Correction: v_off_ini = 621.893 uV, v_off_fin = 624.511 uV 11:59:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.640 uVs 11:59:12 Integrated Voltage Measurement... 11:59:21 Voltage Offset Correction: v_off_ini = 614.284 uV, v_off_fin = 609.899 uV 11:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.858 uVs 11:59:21 Integrated Voltage Measurement... 11:59:30 Voltage Offset Correction: v_off_ini = 618.359 uV, v_off_fin = 613.802 uV 11:59:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.613 uVs 11:59:30 Integrated Voltage Measurement... 11:59:39 Voltage Offset Correction: v_off_ini = 622.671 uV, v_off_fin = 617.624 uV 11:59:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.503 uVs 11:59:41 I2Y Average and RMS of Measurements VT = -444.456 +- 3.983 uVs I2Y = -40.890 +- 0.366 uTm^2 11:59:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:57 Integrated Voltage Measurement... 12:00:06 Voltage Offset Correction: v_off_ini = 628.699 uV, v_off_fin = 619.730 uV 12:00:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -162.100 uVs 12:00:06 Integrated Voltage Measurement... 12:00:15 Voltage Offset Correction: v_off_ini = 608.980 uV, v_off_fin = 613.826 uV 12:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 136.496 uVs 12:00:15 Integrated Voltage Measurement... 12:00:24 Voltage Offset Correction: v_off_ini = 621.334 uV, v_off_fin = 617.905 uV 12:00:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.006 uVs 12:00:24 Integrated Voltage Measurement... 12:00:33 Voltage Offset Correction: v_off_ini = 616.832 uV, v_off_fin = 629.398 uV 12:00:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.714 uVs 12:00:33 Integrated Voltage Measurement... 12:00:42 Voltage Offset Correction: v_off_ini = 612.369 uV, v_off_fin = 615.386 uV 12:00:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.473 uVs 12:00:42 Integrated Voltage Measurement... 12:00:51 Voltage Offset Correction: v_off_ini = 614.215 uV, v_off_fin = 620.218 uV 12:00:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.050 uVs 12:00:56 I1X Average and RMS of Measurements VT = -151.307 +- 6.325 uVs I1X = 30.264 +- 1.265 uTm 12:00:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:03 Integrated Voltage Measurement... 12:01:11 Voltage Offset Correction: v_off_ini = 608.185 uV, v_off_fin = 603.452 uV 12:01:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.809 uVs 12:01:12 Integrated Voltage Measurement... 12:01:20 Voltage Offset Correction: v_off_ini = 612.233 uV, v_off_fin = 613.529 uV 12:01:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.183 uVs 12:01:21 Integrated Voltage Measurement... 12:01:30 Voltage Offset Correction: v_off_ini = 621.665 uV, v_off_fin = 602.772 uV 12:01:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.600 uVs 12:01:30 Integrated Voltage Measurement... 12:01:39 Voltage Offset Correction: v_off_ini = 609.933 uV, v_off_fin = 638.500 uV 12:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.521 uVs 12:01:39 Integrated Voltage Measurement... 12:01:48 Voltage Offset Correction: v_off_ini = 616.376 uV, v_off_fin = 605.986 uV 12:01:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.725 uVs 12:01:48 Integrated Voltage Measurement... 12:01:57 Voltage Offset Correction: v_off_ini = 618.500 uV, v_off_fin = 626.974 uV 12:01:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.321 uVs 12:02:01 I1Y Average and RMS of Measurements VT = -209.360 +- 1.001 uVs I1Y = -41.868 +- 0.201 uTm 12:02:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:09 Integrated Voltage Measurement... 12:02:18 Voltage Offset Correction: v_off_ini = 628.364 uV, v_off_fin = 608.293 uV 12:02:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -129.777 uVs 12:02:18 Integrated Voltage Measurement... 12:02:27 Voltage Offset Correction: v_off_ini = 612.652 uV, v_off_fin = 624.666 uV 12:02:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.816 uVs 12:02:27 Integrated Voltage Measurement... 12:02:36 Voltage Offset Correction: v_off_ini = 621.336 uV, v_off_fin = 606.234 uV 12:02:36 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -107.539 uVs 12:02:36 Integrated Voltage Measurement... 12:02:45 Voltage Offset Correction: v_off_ini = 620.554 uV, v_off_fin = 623.922 uV 12:02:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.338 uVs 12:02:45 Integrated Voltage Measurement... 12:02:54 Voltage Offset Correction: v_off_ini = 612.226 uV, v_off_fin = 610.955 uV 12:02:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.088 uVs 12:02:54 Integrated Voltage Measurement... 12:03:03 Voltage Offset Correction: v_off_ini = 620.372 uV, v_off_fin = 620.439 uV 12:03:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 122.011 uVs 12:03:06 I2X Average and RMS of Measurements VT = -118.428 +- 6.711 uVs I2X = 10.895 +- 0.617 uTm^2 12:03:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:13 Integrated Voltage Measurement... 12:03:22 Voltage Offset Correction: v_off_ini = 609.657 uV, v_off_fin = 620.245 uV 12:03:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.367 uVs 12:03:23 Integrated Voltage Measurement... 12:03:32 Voltage Offset Correction: v_off_ini = 622.955 uV, v_off_fin = 633.787 uV 12:03:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.586 uVs 12:03:32 Integrated Voltage Measurement... 12:03:41 Voltage Offset Correction: v_off_ini = 619.473 uV, v_off_fin = 630.976 uV 12:03:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.821 uVs 12:03:41 Integrated Voltage Measurement... 12:03:50 Voltage Offset Correction: v_off_ini = 628.999 uV, v_off_fin = 635.508 uV 12:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.682 uVs 12:03:50 Integrated Voltage Measurement... 12:03:59 Voltage Offset Correction: v_off_ini = 613.390 uV, v_off_fin = 623.896 uV 12:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.425 uVs 12:03:59 Integrated Voltage Measurement... 12:04:08 Voltage Offset Correction: v_off_ini = 633.027 uV, v_off_fin = 627.742 uV 12:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 430.707 uVs 12:04:11 I2Y Average and RMS of Measurements VT = -429.765 +- 6.460 uVs I2Y = -39.538 +- 0.594 uTm^2 12:04:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:29 Integrated Voltage Measurement... 12:04:38 Voltage Offset Correction: v_off_ini = 636.183 uV, v_off_fin = 626.681 uV 12:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.271 uVs 12:04:38 Integrated Voltage Measurement... 12:04:47 Voltage Offset Correction: v_off_ini = 624.851 uV, v_off_fin = 623.062 uV 12:04:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.993 uVs 12:04:47 Integrated Voltage Measurement... 12:04:56 Voltage Offset Correction: v_off_ini = 624.201 uV, v_off_fin = 629.204 uV 12:04:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.397 uVs 12:04:56 Integrated Voltage Measurement... 12:05:05 Voltage Offset Correction: v_off_ini = 620.760 uV, v_off_fin = 627.256 uV 12:05:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.061 uVs 12:05:05 Integrated Voltage Measurement... 12:05:14 Voltage Offset Correction: v_off_ini = 645.871 uV, v_off_fin = 628.284 uV 12:05:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.159 uVs 12:05:14 Integrated Voltage Measurement... 12:05:23 Voltage Offset Correction: v_off_ini = 641.877 uV, v_off_fin = 637.765 uV 12:05:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.750 uVs 12:05:28 I1X Average and RMS of Measurements VT = -146.938 +- 1.412 uVs I1X = 29.388 +- 0.282 uTm 12:05:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:34 Integrated Voltage Measurement... 12:05:43 Voltage Offset Correction: v_off_ini = 625.107 uV, v_off_fin = 626.201 uV 12:05:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.019 uVs 12:05:43 Integrated Voltage Measurement... 12:05:52 Voltage Offset Correction: v_off_ini = 623.186 uV, v_off_fin = 647.562 uV 12:05:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.708 uVs 12:05:52 Integrated Voltage Measurement... 12:06:01 Voltage Offset Correction: v_off_ini = 631.618 uV, v_off_fin = 622.695 uV 12:06:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.486 uVs 12:06:01 Integrated Voltage Measurement... 12:06:10 Voltage Offset Correction: v_off_ini = 627.702 uV, v_off_fin = 639.906 uV 12:06:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.571 uVs 12:06:10 Integrated Voltage Measurement... 12:06:19 Voltage Offset Correction: v_off_ini = 633.477 uV, v_off_fin = 624.269 uV 12:06:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.990 uVs 12:06:19 Integrated Voltage Measurement... 12:06:28 Voltage Offset Correction: v_off_ini = 627.573 uV, v_off_fin = 644.440 uV 12:06:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.931 uVs 12:06:33 I1Y Average and RMS of Measurements VT = -200.117 +- 10.180 uVs I1Y = -40.019 +- 2.036 uTm 12:06:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:40 Integrated Voltage Measurement... 12:06:49 Voltage Offset Correction: v_off_ini = 625.899 uV, v_off_fin = 610.381 uV 12:06:49 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -123.969 uVs 12:06:49 Integrated Voltage Measurement... 12:06:58 Voltage Offset Correction: v_off_ini = 624.481 uV, v_off_fin = 642.764 uV 12:06:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.391 uVs 12:06:58 Integrated Voltage Measurement... 12:07:07 Voltage Offset Correction: v_off_ini = 631.529 uV, v_off_fin = 626.960 uV 12:07:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.817 uVs 12:07:08 Integrated Voltage Measurement... 12:07:17 Voltage Offset Correction: v_off_ini = 633.433 uV, v_off_fin = 642.933 uV 12:07:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.200 uVs 12:07:17 Integrated Voltage Measurement... 12:07:26 Voltage Offset Correction: v_off_ini = 636.036 uV, v_off_fin = 617.515 uV 12:07:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.092 uVs 12:07:26 Integrated Voltage Measurement... 12:07:35 Voltage Offset Correction: v_off_ini = 633.199 uV, v_off_fin = 634.228 uV 12:07:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.657 uVs 12:07:37 I2X Average and RMS of Measurements VT = -130.355 +- 2.465 uVs I2X = 11.992 +- 0.227 uTm^2 12:07:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:45 Integrated Voltage Measurement... 12:07:54 Voltage Offset Correction: v_off_ini = 618.472 uV, v_off_fin = 624.073 uV 12:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.820 uVs 12:07:54 Integrated Voltage Measurement... 12:08:03 Voltage Offset Correction: v_off_ini = 619.025 uV, v_off_fin = 622.472 uV 12:08:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.944 uVs 12:08:03 Integrated Voltage Measurement... 12:08:12 Voltage Offset Correction: v_off_ini = 622.590 uV, v_off_fin = 634.840 uV 12:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -409.669 uVs 12:08:12 Integrated Voltage Measurement... 12:08:21 Voltage Offset Correction: v_off_ini = 632.530 uV, v_off_fin = 634.594 uV 12:08:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.974 uVs 12:08:21 Integrated Voltage Measurement... 12:08:30 Voltage Offset Correction: v_off_ini = 638.235 uV, v_off_fin = 635.056 uV 12:08:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.892 uVs 12:08:30 Integrated Voltage Measurement... 12:08:39 Voltage Offset Correction: v_off_ini = 636.897 uV, v_off_fin = 630.133 uV 12:08:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.805 uVs 12:08:41 I2Y Average and RMS of Measurements VT = -399.517 +- 2.079 uVs I2Y = -36.756 +- 0.191 uTm^2 12:08:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:00 Integrated Voltage Measurement... 12:09:09 Voltage Offset Correction: v_off_ini = 630.977 uV, v_off_fin = 632.056 uV 12:09:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -154.779 uVs 12:09:09 Integrated Voltage Measurement... 12:09:18 Voltage Offset Correction: v_off_ini = 621.687 uV, v_off_fin = 627.956 uV 12:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.309 uVs 12:09:18 Integrated Voltage Measurement... 12:09:27 Voltage Offset Correction: v_off_ini = 619.990 uV, v_off_fin = 615.431 uV 12:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.619 uVs 12:09:27 Integrated Voltage Measurement... 12:09:36 Voltage Offset Correction: v_off_ini = 624.164 uV, v_off_fin = 605.735 uV 12:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.293 uVs 12:09:36 Integrated Voltage Measurement... 12:09:45 Voltage Offset Correction: v_off_ini = 614.586 uV, v_off_fin = 611.856 uV 12:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.526 uVs 12:09:45 Integrated Voltage Measurement... 12:09:54 Voltage Offset Correction: v_off_ini = 621.425 uV, v_off_fin = 622.925 uV 12:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.489 uVs 12:09:58 I1X Average and RMS of Measurements VT = -141.669 +- 5.135 uVs I1X = 28.336 +- 1.028 uTm 12:10:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:05 Integrated Voltage Measurement... 12:10:14 Voltage Offset Correction: v_off_ini = 626.315 uV, v_off_fin = 620.456 uV 12:10:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.622 uVs 12:10:14 Integrated Voltage Measurement... 12:10:23 Voltage Offset Correction: v_off_ini = 608.622 uV, v_off_fin = 633.645 uV 12:10:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.669 uVs 12:10:23 Integrated Voltage Measurement... 12:10:32 Voltage Offset Correction: v_off_ini = 608.035 uV, v_off_fin = 598.249 uV 12:10:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.903 uVs 12:10:32 Integrated Voltage Measurement... 12:10:41 Voltage Offset Correction: v_off_ini = 604.863 uV, v_off_fin = 625.293 uV 12:10:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.039 uVs 12:10:41 Integrated Voltage Measurement... 12:10:50 Voltage Offset Correction: v_off_ini = 613.373 uV, v_off_fin = 603.158 uV 12:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.425 uVs 12:10:50 Integrated Voltage Measurement... 12:10:59 Voltage Offset Correction: v_off_ini = 614.207 uV, v_off_fin = 627.307 uV 12:10:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.186 uVs 12:11:03 I1Y Average and RMS of Measurements VT = -200.641 +- 1.444 uVs I1Y = -40.125 +- 0.289 uTm 12:11:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:11 Integrated Voltage Measurement... 12:11:20 Voltage Offset Correction: v_off_ini = 613.512 uV, v_off_fin = 602.383 uV 12:11:20 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -119.810 uVs 12:11:20 Integrated Voltage Measurement... 12:11:29 Voltage Offset Correction: v_off_ini = 609.600 uV, v_off_fin = 611.957 uV 12:11:29 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 122.820 uVs 12:11:29 Integrated Voltage Measurement... 12:11:38 Voltage Offset Correction: v_off_ini = 602.727 uV, v_off_fin = 603.025 uV 12:11:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -98.956 uVs 12:11:38 Integrated Voltage Measurement... 12:11:47 Voltage Offset Correction: v_off_ini = 610.966 uV, v_off_fin = 621.253 uV 12:11:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.585 uVs 12:11:47 Integrated Voltage Measurement... 12:11:56 Voltage Offset Correction: v_off_ini = 619.237 uV, v_off_fin = 613.278 uV 12:11:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.786 uVs 12:11:57 Integrated Voltage Measurement... 12:12:06 Voltage Offset Correction: v_off_ini = 619.490 uV, v_off_fin = 617.722 uV 12:12:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.191 uVs 12:12:08 I2X Average and RMS of Measurements VT = -113.858 +- 5.319 uVs I2X = 10.475 +- 0.489 uTm^2 12:12:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:16 Integrated Voltage Measurement... 12:12:25 Voltage Offset Correction: v_off_ini = 608.910 uV, v_off_fin = 607.741 uV 12:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -381.096 uVs 12:12:25 Integrated Voltage Measurement... 12:12:34 Voltage Offset Correction: v_off_ini = 604.776 uV, v_off_fin = 605.302 uV 12:12:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.815 uVs 12:12:34 Integrated Voltage Measurement... 12:12:43 Voltage Offset Correction: v_off_ini = 599.262 uV, v_off_fin = 611.087 uV 12:12:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.079 uVs 12:12:43 Integrated Voltage Measurement... 12:12:52 Voltage Offset Correction: v_off_ini = 600.079 uV, v_off_fin = 606.320 uV 12:12:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.999 uVs 12:12:52 Integrated Voltage Measurement... 12:13:01 Voltage Offset Correction: v_off_ini = 606.838 uV, v_off_fin = 610.550 uV 12:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.759 uVs 12:13:01 Integrated Voltage Measurement... 12:13:10 Voltage Offset Correction: v_off_ini = 612.093 uV, v_off_fin = 614.438 uV 12:13:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 365.396 uVs 12:13:12 I2Y Average and RMS of Measurements VT = -376.857 +- 9.853 uVs I2Y = -34.671 +- 0.906 uTm^2 12:13:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:31 Integrated Voltage Measurement... 12:13:40 Voltage Offset Correction: v_off_ini = 622.933 uV, v_off_fin = 618.168 uV 12:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -126.332 uVs 12:13:40 Integrated Voltage Measurement... 12:13:49 Voltage Offset Correction: v_off_ini = 612.278 uV, v_off_fin = 618.682 uV 12:13:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.584 uVs 12:13:49 Integrated Voltage Measurement... 12:13:58 Voltage Offset Correction: v_off_ini = 618.665 uV, v_off_fin = 628.936 uV 12:13:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.675 uVs 12:13:58 Integrated Voltage Measurement... 12:14:07 Voltage Offset Correction: v_off_ini = 616.662 uV, v_off_fin = 628.430 uV 12:14:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 129.268 uVs 12:14:07 Integrated Voltage Measurement... 12:14:16 Voltage Offset Correction: v_off_ini = 619.615 uV, v_off_fin = 629.702 uV 12:14:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.807 uVs 12:14:16 Integrated Voltage Measurement... 12:14:25 Voltage Offset Correction: v_off_ini = 631.700 uV, v_off_fin = 620.352 uV 12:14:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.426 uVs 12:14:29 I1X Average and RMS of Measurements VT = -130.515 +- 0.741 uVs I1X = 26.105 +- 0.147 uTm 12:14:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:14:36 Integrated Voltage Measurement... 12:14:45 Voltage Offset Correction: v_off_ini = 627.546 uV, v_off_fin = 623.403 uV 12:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.905 uVs 12:14:45 Integrated Voltage Measurement... 12:14:54 Voltage Offset Correction: v_off_ini = 622.160 uV, v_off_fin = 650.610 uV 12:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.566 uVs 12:14:54 Integrated Voltage Measurement... 12:15:03 Voltage Offset Correction: v_off_ini = 639.784 uV, v_off_fin = 620.020 uV 12:15:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.601 uVs 12:15:03 Integrated Voltage Measurement... 12:15:12 Voltage Offset Correction: v_off_ini = 640.314 uV, v_off_fin = 631.068 uV 12:15:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.990 uVs 12:15:12 Integrated Voltage Measurement... 12:15:21 Voltage Offset Correction: v_off_ini = 618.395 uV, v_off_fin = 608.338 uV 12:15:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.048 uVs 12:15:21 Integrated Voltage Measurement... 12:15:30 Voltage Offset Correction: v_off_ini = 618.368 uV, v_off_fin = 630.720 uV 12:15:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.985 uVs 12:15:34 I1Y Average and RMS of Measurements VT = -201.183 +- 3.847 uVs I1Y = -40.235 +- 0.771 uTm 12:15:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:42 Integrated Voltage Measurement... 12:15:51 Voltage Offset Correction: v_off_ini = 632.953 uV, v_off_fin = 609.190 uV 12:15:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -128.818 uVs 12:15:51 Integrated Voltage Measurement... 12:16:00 Voltage Offset Correction: v_off_ini = 618.609 uV, v_off_fin = 629.491 uV 12:16:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.532 uVs 12:16:00 Integrated Voltage Measurement... 12:16:09 Voltage Offset Correction: v_off_ini = 618.518 uV, v_off_fin = 601.090 uV 12:16:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.881 uVs 12:16:09 Integrated Voltage Measurement... 12:16:18 Voltage Offset Correction: v_off_ini = 620.571 uV, v_off_fin = 624.209 uV 12:16:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.458 uVs 12:16:18 Integrated Voltage Measurement... 12:16:27 Voltage Offset Correction: v_off_ini = 604.307 uV, v_off_fin = 617.699 uV 12:16:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.627 uVs 12:16:27 Integrated Voltage Measurement... 12:16:36 Voltage Offset Correction: v_off_ini = 621.328 uV, v_off_fin = 630.304 uV 12:16:37 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 107.025 uVs 12:16:39 I2X Average and RMS of Measurements VT = -114.224 +- 4.565 uVs I2X = 10.509 +- 0.419 uTm^2 12:16:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:16:47 Integrated Voltage Measurement... 12:16:56 Voltage Offset Correction: v_off_ini = 632.947 uV, v_off_fin = 630.094 uV 12:16:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.734 uVs 12:16:56 Integrated Voltage Measurement... 12:17:05 Voltage Offset Correction: v_off_ini = 628.809 uV, v_off_fin = 631.578 uV 12:17:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.789 uVs 12:17:05 Integrated Voltage Measurement... 12:17:14 Voltage Offset Correction: v_off_ini = 635.240 uV, v_off_fin = 633.891 uV 12:17:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.240 uVs 12:17:14 Integrated Voltage Measurement... 12:17:23 Voltage Offset Correction: v_off_ini = 630.787 uV, v_off_fin = 633.807 uV 12:17:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.609 uVs 12:17:23 Integrated Voltage Measurement... 12:17:32 Voltage Offset Correction: v_off_ini = 633.349 uV, v_off_fin = 624.072 uV 12:17:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.472 uVs 12:17:32 Integrated Voltage Measurement... 12:17:41 Voltage Offset Correction: v_off_ini = 621.343 uV, v_off_fin = 623.527 uV 12:17:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.879 uVs 12:17:43 I2Y Average and RMS of Measurements VT = -354.454 +- 12.955 uVs I2Y = -32.610 +- 1.192 uTm^2 12:17:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:02 Integrated Voltage Measurement... 12:18:11 Voltage Offset Correction: v_off_ini = 638.101 uV, v_off_fin = 622.178 uV 12:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.155 uVs 12:18:11 Integrated Voltage Measurement... 12:18:20 Voltage Offset Correction: v_off_ini = 622.075 uV, v_off_fin = 635.873 uV 12:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.144 uVs 12:18:20 Integrated Voltage Measurement... 12:18:29 Voltage Offset Correction: v_off_ini = 619.197 uV, v_off_fin = 623.385 uV 12:18:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.562 uVs 12:18:29 Integrated Voltage Measurement... 12:18:38 Voltage Offset Correction: v_off_ini = 634.101 uV, v_off_fin = 631.880 uV 12:18:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.952 uVs 12:18:38 Integrated Voltage Measurement... 12:18:47 Voltage Offset Correction: v_off_ini = 620.392 uV, v_off_fin = 622.955 uV 12:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.469 uVs 12:18:47 Integrated Voltage Measurement... 12:18:56 Voltage Offset Correction: v_off_ini = 605.674 uV, v_off_fin = 603.903 uV 12:18:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.308 uVs 12:19:00 I1X Average and RMS of Measurements VT = -122.765 +- 4.507 uVs I1X = 24.553 +- 0.902 uTm 12:19:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:07 Integrated Voltage Measurement... 12:19:16 Voltage Offset Correction: v_off_ini = 600.165 uV, v_off_fin = 596.737 uV 12:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.755 uVs 12:19:16 Integrated Voltage Measurement... 12:19:25 Voltage Offset Correction: v_off_ini = 604.218 uV, v_off_fin = 612.915 uV 12:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.485 uVs 12:19:25 Integrated Voltage Measurement... 12:19:34 Voltage Offset Correction: v_off_ini = 611.394 uV, v_off_fin = 597.162 uV 12:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.534 uVs 12:19:34 Integrated Voltage Measurement... 12:19:43 Voltage Offset Correction: v_off_ini = 604.331 uV, v_off_fin = 620.360 uV 12:19:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.847 uVs 12:19:43 Integrated Voltage Measurement... 12:19:51 Voltage Offset Correction: v_off_ini = 614.991 uV, v_off_fin = 593.480 uV 12:19:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -200.953 uVs 12:19:52 Integrated Voltage Measurement... 12:20:00 Voltage Offset Correction: v_off_ini = 610.174 uV, v_off_fin = 619.026 uV 12:20:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.249 uVs 12:20:05 I1Y Average and RMS of Measurements VT = -191.970 +- 5.980 uVs I1Y = -38.391 +- 1.195 uTm 12:20:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:12 Integrated Voltage Measurement... 12:20:21 Voltage Offset Correction: v_off_ini = 618.906 uV, v_off_fin = 591.191 uV 12:20:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.193 uVs 12:20:21 Integrated Voltage Measurement... 12:20:30 Voltage Offset Correction: v_off_ini = 600.081 uV, v_off_fin = 619.918 uV 12:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.983 uVs 12:20:30 Integrated Voltage Measurement... 12:20:39 Voltage Offset Correction: v_off_ini = 612.239 uV, v_off_fin = 600.074 uV 12:20:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.061 uVs 12:20:40 Integrated Voltage Measurement... 12:20:48 Voltage Offset Correction: v_off_ini = 613.587 uV, v_off_fin = 623.414 uV 12:20:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.001 uVs 12:20:49 Integrated Voltage Measurement... 12:20:58 Voltage Offset Correction: v_off_ini = 611.557 uV, v_off_fin = 606.357 uV 12:20:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.328 uVs 12:20:58 Integrated Voltage Measurement... 12:21:07 Voltage Offset Correction: v_off_ini = 622.340 uV, v_off_fin = 629.869 uV 12:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.725 uVs 12:21:09 I2X Average and RMS of Measurements VT = -108.215 +- 8.352 uVs I2X = 9.956 +- 0.768 uTm^2 12:21:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:17 Integrated Voltage Measurement... 12:21:26 Voltage Offset Correction: v_off_ini = 624.327 uV, v_off_fin = 614.757 uV 12:21:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.300 uVs 12:21:26 Integrated Voltage Measurement... 12:21:35 Voltage Offset Correction: v_off_ini = 635.608 uV, v_off_fin = 632.572 uV 12:21:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.861 uVs 12:21:35 Integrated Voltage Measurement... 12:21:44 Voltage Offset Correction: v_off_ini = 629.110 uV, v_off_fin = 622.345 uV 12:21:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.527 uVs 12:21:44 Integrated Voltage Measurement... 12:21:53 Voltage Offset Correction: v_off_ini = 625.630 uV, v_off_fin = 620.957 uV 12:21:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.913 uVs 12:21:53 Integrated Voltage Measurement... 12:22:02 Voltage Offset Correction: v_off_ini = 619.576 uV, v_off_fin = 615.444 uV 12:22:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.050 uVs 12:22:02 Integrated Voltage Measurement... 12:22:11 Voltage Offset Correction: v_off_ini = 628.380 uV, v_off_fin = 626.747 uV 12:22:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.087 uVs 12:22:13 I2Y Average and RMS of Measurements VT = -332.623 +- 8.801 uVs I2Y = -30.601 +- 0.810 uTm^2 12:22:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:31 Integrated Voltage Measurement... 12:22:40 Voltage Offset Correction: v_off_ini = 615.421 uV, v_off_fin = 619.937 uV 12:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.962 uVs 12:22:41 Integrated Voltage Measurement... 12:22:50 Voltage Offset Correction: v_off_ini = 630.591 uV, v_off_fin = 636.010 uV 12:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.813 uVs 12:22:50 Integrated Voltage Measurement... 12:22:59 Voltage Offset Correction: v_off_ini = 623.838 uV, v_off_fin = 622.363 uV 12:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.760 uVs 12:22:59 Integrated Voltage Measurement... 12:23:08 Voltage Offset Correction: v_off_ini = 620.771 uV, v_off_fin = 642.741 uV 12:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.190 uVs 12:23:08 Integrated Voltage Measurement... 12:23:17 Voltage Offset Correction: v_off_ini = 629.520 uV, v_off_fin = 624.566 uV 12:23:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.217 uVs 12:23:17 Integrated Voltage Measurement... 12:23:26 Voltage Offset Correction: v_off_ini = 641.873 uV, v_off_fin = 633.962 uV 12:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.562 uVs 12:23:30 I1X Average and RMS of Measurements VT = -108.584 +- 5.196 uVs I1X = 21.717 +- 1.039 uTm 12:23:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:23:37 Integrated Voltage Measurement... 12:23:46 Voltage Offset Correction: v_off_ini = 658.111 uV, v_off_fin = 630.445 uV 12:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.592 uVs 12:23:46 Integrated Voltage Measurement... 12:23:55 Voltage Offset Correction: v_off_ini = 640.985 uV, v_off_fin = 656.043 uV 12:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.977 uVs 12:23:55 Integrated Voltage Measurement... 12:24:04 Voltage Offset Correction: v_off_ini = 652.139 uV, v_off_fin = 639.960 uV 12:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.653 uVs 12:24:04 Integrated Voltage Measurement... 12:24:13 Voltage Offset Correction: v_off_ini = 643.245 uV, v_off_fin = 659.983 uV 12:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.563 uVs 12:24:13 Integrated Voltage Measurement... 12:24:22 Voltage Offset Correction: v_off_ini = 648.402 uV, v_off_fin = 630.212 uV 12:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.984 uVs 12:24:22 Integrated Voltage Measurement... 12:24:31 Voltage Offset Correction: v_off_ini = 642.842 uV, v_off_fin = 647.109 uV 12:24:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.586 uVs 12:24:35 I1Y Average and RMS of Measurements VT = -200.226 +- 5.366 uVs I1Y = -40.044 +- 1.074 uTm 12:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:43 Integrated Voltage Measurement... 12:24:52 Voltage Offset Correction: v_off_ini = 639.649 uV, v_off_fin = 634.879 uV 12:24:52 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.250 uVs 12:24:52 Integrated Voltage Measurement... 12:25:01 Voltage Offset Correction: v_off_ini = 636.917 uV, v_off_fin = 643.931 uV 12:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.016 uVs 12:25:01 Integrated Voltage Measurement... 12:25:10 Voltage Offset Correction: v_off_ini = 631.919 uV, v_off_fin = 633.501 uV 12:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.882 uVs 12:25:10 Integrated Voltage Measurement... 12:25:19 Voltage Offset Correction: v_off_ini = 644.867 uV, v_off_fin = 648.275 uV 12:25:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.521 uVs 12:25:19 Integrated Voltage Measurement... 12:25:28 Voltage Offset Correction: v_off_ini = 637.855 uV, v_off_fin = 636.560 uV 12:25:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.403 uVs 12:25:28 Integrated Voltage Measurement... 12:25:37 Voltage Offset Correction: v_off_ini = 634.589 uV, v_off_fin = 654.550 uV 12:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.442 uVs 12:25:39 I2X Average and RMS of Measurements VT = -100.586 +- 4.484 uVs I2X = 9.254 +- 0.413 uTm^2 12:25:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:47 Integrated Voltage Measurement... 12:25:56 Voltage Offset Correction: v_off_ini = 647.255 uV, v_off_fin = 639.397 uV 12:25:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.830 uVs 12:25:56 Integrated Voltage Measurement... 12:26:05 Voltage Offset Correction: v_off_ini = 645.375 uV, v_off_fin = 646.541 uV 12:26:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.566 uVs 12:26:05 Integrated Voltage Measurement... 12:26:14 Voltage Offset Correction: v_off_ini = 639.728 uV, v_off_fin = 651.576 uV 12:26:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.690 uVs 12:26:14 Integrated Voltage Measurement... 12:26:23 Voltage Offset Correction: v_off_ini = 649.768 uV, v_off_fin = 643.764 uV 12:26:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.438 uVs 12:26:23 Integrated Voltage Measurement... 12:26:32 Voltage Offset Correction: v_off_ini = 649.518 uV, v_off_fin = 666.088 uV 12:26:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.370 uVs 12:26:32 Integrated Voltage Measurement... 12:26:41 Voltage Offset Correction: v_off_ini = 662.032 uV, v_off_fin = 669.353 uV 12:26:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.080 uVs 12:26:43 I2Y Average and RMS of Measurements VT = -326.496 +- 4.781 uVs I2Y = -30.038 +- 0.440 uTm^2 12:26:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:02 Integrated Voltage Measurement... 12:27:11 Voltage Offset Correction: v_off_ini = 664.319 uV, v_off_fin = 667.228 uV 12:27:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.034 uVs 12:27:11 Integrated Voltage Measurement... 12:27:20 Voltage Offset Correction: v_off_ini = 680.784 uV, v_off_fin = 683.453 uV 12:27:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.225 uVs 12:27:20 Integrated Voltage Measurement... 12:27:29 Voltage Offset Correction: v_off_ini = 670.142 uV, v_off_fin = 673.827 uV 12:27:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.955 uVs 12:27:29 Integrated Voltage Measurement... 12:27:38 Voltage Offset Correction: v_off_ini = 680.891 uV, v_off_fin = 681.568 uV 12:27:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 121.159 uVs 12:27:38 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = 679.200 uV, v_off_fin = 679.591 uV 12:27:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.743 uVs 12:27:47 Integrated Voltage Measurement... 12:27:56 Voltage Offset Correction: v_off_ini = 666.502 uV, v_off_fin = 677.640 uV 12:27:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.929 uVs 12:28:00 I1X Average and RMS of Measurements VT = -110.007 +- 5.558 uVs I1X = 22.003 +- 1.113 uTm 12:28:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:07 Integrated Voltage Measurement... 12:28:16 Voltage Offset Correction: v_off_ini = 684.749 uV, v_off_fin = 679.119 uV 12:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.279 uVs 12:28:16 Integrated Voltage Measurement... 12:28:25 Voltage Offset Correction: v_off_ini = 667.194 uV, v_off_fin = 690.890 uV 12:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.000 uVs 12:28:25 Integrated Voltage Measurement... 12:28:34 Voltage Offset Correction: v_off_ini = 685.221 uV, v_off_fin = 664.035 uV 12:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.654 uVs 12:28:34 Integrated Voltage Measurement... 12:28:43 Voltage Offset Correction: v_off_ini = 680.986 uV, v_off_fin = 688.058 uV 12:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.940 uVs 12:28:43 Integrated Voltage Measurement... 12:28:52 Voltage Offset Correction: v_off_ini = 680.628 uV, v_off_fin = 658.763 uV 12:28:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.394 uVs 12:28:52 Integrated Voltage Measurement... 12:29:01 Voltage Offset Correction: v_off_ini = 675.576 uV, v_off_fin = 687.326 uV 12:29:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.711 uVs 12:29:05 I1Y Average and RMS of Measurements VT = -207.496 +- 5.447 uVs I1Y = -41.496 +- 1.089 uTm 12:29:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:13 Integrated Voltage Measurement... 12:29:22 Voltage Offset Correction: v_off_ini = 677.185 uV, v_off_fin = 650.451 uV 12:29:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -117.565 uVs 12:29:22 Integrated Voltage Measurement... 12:29:31 Voltage Offset Correction: v_off_ini = 659.361 uV, v_off_fin = 672.765 uV 12:29:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.779 uVs 12:29:31 Integrated Voltage Measurement... 12:29:40 Voltage Offset Correction: v_off_ini = 658.368 uV, v_off_fin = 659.693 uV 12:29:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.537 uVs 12:29:40 Integrated Voltage Measurement... 12:29:49 Voltage Offset Correction: v_off_ini = 663.953 uV, v_off_fin = 679.355 uV 12:29:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.155 uVs 12:29:49 Integrated Voltage Measurement... 12:29:58 Voltage Offset Correction: v_off_ini = 655.160 uV, v_off_fin = 643.958 uV 12:29:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.167 uVs 12:29:58 Integrated Voltage Measurement... 12:30:07 Voltage Offset Correction: v_off_ini = 657.544 uV, v_off_fin = 670.627 uV 12:30:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.477 uVs 12:30:10 I2X Average and RMS of Measurements VT = -104.447 +- 3.280 uVs I2X = 9.609 +- 0.302 uTm^2 12:30:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:17 Integrated Voltage Measurement... 12:30:26 Voltage Offset Correction: v_off_ini = 654.417 uV, v_off_fin = 651.466 uV 12:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.007 uVs 12:30:26 Integrated Voltage Measurement... 12:30:35 Voltage Offset Correction: v_off_ini = 659.839 uV, v_off_fin = 655.290 uV 12:30:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.020 uVs 12:30:36 Integrated Voltage Measurement... 12:30:45 Voltage Offset Correction: v_off_ini = 662.784 uV, v_off_fin = 649.513 uV 12:30:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.293 uVs 12:30:45 Integrated Voltage Measurement... 12:30:54 Voltage Offset Correction: v_off_ini = 654.746 uV, v_off_fin = 654.442 uV 12:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.836 uVs 12:30:54 Integrated Voltage Measurement... 12:31:03 Voltage Offset Correction: v_off_ini = 668.906 uV, v_off_fin = 670.884 uV 12:31:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.645 uVs 12:31:03 Integrated Voltage Measurement... 12:31:12 Voltage Offset Correction: v_off_ini = 663.259 uV, v_off_fin = 657.894 uV 12:31:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.392 uVs 12:31:14 I2Y Average and RMS of Measurements VT = -313.365 +- 0.872 uVs I2Y = -28.830 +- 0.080 uTm^2 12:31:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm