SLAC Magnetic Measurements Date: 06-12-2025 Time: 14:57:19 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16352 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 1 Measurement Device: Operator: YL Comment: Off Axis 14:57:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:29 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:57:31 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:57:32 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:57:34 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:58:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:58:35 Integrated Voltage Measurement... 14:58:44 Voltage Offset Correction: v_off_ini = 255.852 uV, v_off_fin = 251.355 uV 14:58:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -6.722 uVs 14:58:44 Integrated Voltage Measurement... 14:58:53 Voltage Offset Correction: v_off_ini = 267.679 uV, v_off_fin = 259.127 uV 14:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.243 uVs 14:58:53 Integrated Voltage Measurement... 14:59:02 Voltage Offset Correction: v_off_ini = 249.017 uV, v_off_fin = 253.445 uV 14:59:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.288 uVs 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 248.482 uV, v_off_fin = 256.030 uV 14:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.024 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 249.654 uV, v_off_fin = 256.971 uV 14:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.207 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 261.177 uV, v_off_fin = 253.406 uV 14:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 15.075 uVs 14:59:34 I1X Average and RMS of Measurements VT = -24.093 +- 12.234 uVs I1X = 4.819 +- 2.447 uTm 14:59:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:59:40 Integrated Voltage Measurement... 14:59:49 Voltage Offset Correction: v_off_ini = 246.341 uV, v_off_fin = 258.520 uV 14:59:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.181 uVs 14:59:49 Integrated Voltage Measurement... 14:59:58 Voltage Offset Correction: v_off_ini = 269.274 uV, v_off_fin = 275.750 uV 14:59:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.666 uVs 14:59:58 Integrated Voltage Measurement... 15:00:07 Voltage Offset Correction: v_off_ini = 260.149 uV, v_off_fin = 264.742 uV 15:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.974 uVs 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 275.103 uV, v_off_fin = 286.824 uV 15:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.066 uVs 15:00:16 Integrated Voltage Measurement... 15:00:25 Voltage Offset Correction: v_off_ini = 268.733 uV, v_off_fin = 256.609 uV 15:00:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.117 uVs 15:00:25 Integrated Voltage Measurement... 15:00:34 Voltage Offset Correction: v_off_ini = 261.714 uV, v_off_fin = 275.908 uV 15:00:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.182 uVs 15:00:38 I1Y Average and RMS of Measurements VT = -245.364 +- 0.969 uVs I1Y = -49.073 +- 0.194 uTm 15:00:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:00:46 Integrated Voltage Measurement... 15:00:55 Voltage Offset Correction: v_off_ini = 251.228 uV, v_off_fin = 249.654 uV 15:00:55 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = 24.604 uVs 15:00:55 Integrated Voltage Measurement... 15:01:04 Voltage Offset Correction: v_off_ini = 273.110 uV, v_off_fin = 285.081 uV 15:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -11.854 uVs 15:01:04 Integrated Voltage Measurement... 15:01:13 Voltage Offset Correction: v_off_ini = 272.288 uV, v_off_fin = 269.102 uV 15:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.954 uVs 15:01:13 Integrated Voltage Measurement... 15:01:22 Voltage Offset Correction: v_off_ini = 259.056 uV, v_off_fin = 289.666 uV 15:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.650 uVs 15:01:22 Integrated Voltage Measurement... 15:01:31 Voltage Offset Correction: v_off_ini = 285.340 uV, v_off_fin = 273.527 uV 15:01:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.857 uVs 15:01:31 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = 278.535 uV, v_off_fin = 292.635 uV 15:01:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.240 uVs 15:01:42 I2X Average and RMS of Measurements VT = 3.873 +- 11.099 uVs I2X = -0.356 +- 1.021 uTm^2 15:01:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:01:50 Integrated Voltage Measurement... 15:01:59 Voltage Offset Correction: v_off_ini = 285.612 uV, v_off_fin = 292.447 uV 15:01:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.673 uVs 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 294.436 uV, v_off_fin = 294.942 uV 15:02:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.652 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 288.954 uV, v_off_fin = 295.843 uV 15:02:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -256.507 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 299.972 uV, v_off_fin = 303.904 uV 15:02:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.306 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 291.494 uV, v_off_fin = 289.316 uV 15:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.898 uVs 15:02:35 Integrated Voltage Measurement... 15:02:44 Voltage Offset Correction: v_off_ini = 280.395 uV, v_off_fin = 292.760 uV 15:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.891 uVs 15:02:47 I2Y Average and RMS of Measurements VT = -250.155 +- 0.548 uVs I2Y = -23.015 +- 0.051 uTm^2 15:02:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:02:55 Integrated Voltage Measurement... 15:03:04 Voltage Offset Correction: v_off_ini = 287.714 uV, v_off_fin = 271.320 uV 15:03:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.015 uVs 15:03:05 Integrated Voltage Measurement... 15:03:13 Voltage Offset Correction: v_off_ini = 275.693 uV, v_off_fin = 281.113 uV 15:03:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.201 uVs 15:03:14 Integrated Voltage Measurement... 15:03:22 Voltage Offset Correction: v_off_ini = 298.276 uV, v_off_fin = 291.318 uV 15:03:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.426 uVs 15:03:22 Integrated Voltage Measurement... 15:03:31 Voltage Offset Correction: v_off_ini = 300.103 uV, v_off_fin = 290.868 uV 15:03:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.759 uVs 15:03:32 Integrated Voltage Measurement... 15:03:40 Voltage Offset Correction: v_off_ini = 280.824 uV, v_off_fin = 284.883 uV 15:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.190 uVs 15:03:41 Integrated Voltage Measurement... 15:03:49 Voltage Offset Correction: v_off_ini = 294.859 uV, v_off_fin = 306.669 uV 15:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.274 uVs 15:03:54 I1X Average and RMS of Measurements VT = -42.811 +- 9.152 uVs I1X = 8.562 +- 1.831 uTm 15:03:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:04:00 Integrated Voltage Measurement... 15:04:09 Voltage Offset Correction: v_off_ini = 296.368 uV, v_off_fin = 287.181 uV 15:04:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.168 uVs 15:04:09 Integrated Voltage Measurement... 15:04:18 Voltage Offset Correction: v_off_ini = 297.628 uV, v_off_fin = 305.373 uV 15:04:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.077 uVs 15:04:18 Integrated Voltage Measurement... 15:04:27 Voltage Offset Correction: v_off_ini = 296.690 uV, v_off_fin = 292.026 uV 15:04:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.082 uVs 15:04:27 Integrated Voltage Measurement... 15:04:36 Voltage Offset Correction: v_off_ini = 296.630 uV, v_off_fin = 307.458 uV 15:04:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.863 uVs 15:04:36 Integrated Voltage Measurement... 15:04:45 Voltage Offset Correction: v_off_ini = 306.733 uV, v_off_fin = 283.675 uV 15:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.493 uVs 15:04:45 Integrated Voltage Measurement... 15:04:54 Voltage Offset Correction: v_off_ini = 291.766 uV, v_off_fin = 308.119 uV 15:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.712 uVs 15:04:58 I1Y Average and RMS of Measurements VT = -230.233 +- 3.126 uVs I1Y = -46.047 +- 0.625 uTm 15:05:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:05:06 Integrated Voltage Measurement... 15:05:15 Voltage Offset Correction: v_off_ini = 293.188 uV, v_off_fin = 283.331 uV 15:05:15 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -33.260 uVs 15:05:15 Integrated Voltage Measurement... 15:05:24 Voltage Offset Correction: v_off_ini = 295.376 uV, v_off_fin = 293.835 uV 15:05:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.158 uVs 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 294.598 uV, v_off_fin = 278.935 uV 15:05:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.843 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 295.951 uV, v_off_fin = 297.605 uV 15:05:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.739 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = 288.913 uV, v_off_fin = 288.417 uV 15:05:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.314 uVs 15:05:51 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = 290.339 uV, v_off_fin = 291.501 uV 15:06:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.032 uVs 15:06:03 I2X Average and RMS of Measurements VT = -18.724 +- 5.996 uVs I2X = 1.723 +- 0.552 uTm^2 15:06:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:06:10 Integrated Voltage Measurement... 15:06:19 Voltage Offset Correction: v_off_ini = 284.868 uV, v_off_fin = 284.468 uV 15:06:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.007 uVs 15:06:19 Integrated Voltage Measurement... 15:06:28 Voltage Offset Correction: v_off_ini = 278.341 uV, v_off_fin = 274.725 uV 15:06:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.776 uVs 15:06:28 Integrated Voltage Measurement... 15:06:37 Voltage Offset Correction: v_off_ini = 273.442 uV, v_off_fin = 277.535 uV 15:06:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.161 uVs 15:06:37 Integrated Voltage Measurement... 15:06:46 Voltage Offset Correction: v_off_ini = 274.928 uV, v_off_fin = 273.380 uV 15:06:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.752 uVs 15:06:46 Integrated Voltage Measurement... 15:06:55 Voltage Offset Correction: v_off_ini = 271.630 uV, v_off_fin = 273.784 uV 15:06:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.751 uVs 15:06:55 Integrated Voltage Measurement... 15:07:04 Voltage Offset Correction: v_off_ini = 281.443 uV, v_off_fin = 273.655 uV 15:07:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.733 uVs 15:07:07 I2Y Average and RMS of Measurements VT = -229.863 +- 5.437 uVs I2Y = -21.147 +- 0.500 uTm^2 15:07:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:16 Integrated Voltage Measurement... 15:07:25 Voltage Offset Correction: v_off_ini = 284.420 uV, v_off_fin = 280.405 uV 15:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.871 uVs 15:07:25 Integrated Voltage Measurement... 15:07:34 Voltage Offset Correction: v_off_ini = 274.193 uV, v_off_fin = 278.095 uV 15:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.202 uVs 15:07:34 Integrated Voltage Measurement... 15:07:43 Voltage Offset Correction: v_off_ini = 278.000 uV, v_off_fin = 275.967 uV 15:07:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.605 uVs 15:07:43 Integrated Voltage Measurement... 15:07:52 Voltage Offset Correction: v_off_ini = 282.489 uV, v_off_fin = 286.675 uV 15:07:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.792 uVs 15:07:52 Integrated Voltage Measurement... 15:08:01 Voltage Offset Correction: v_off_ini = 290.235 uV, v_off_fin = 286.582 uV 15:08:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.498 uVs 15:08:01 Integrated Voltage Measurement... 15:08:10 Voltage Offset Correction: v_off_ini = 274.903 uV, v_off_fin = 271.557 uV 15:08:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.136 uVs 15:08:14 I1X Average and RMS of Measurements VT = -54.684 +- 7.468 uVs I1X = 10.937 +- 1.493 uTm 15:08:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:21 Integrated Voltage Measurement... 15:08:29 Voltage Offset Correction: v_off_ini = 269.359 uV, v_off_fin = 266.980 uV 15:08:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.839 uVs 15:08:29 Integrated Voltage Measurement... 15:08:38 Voltage Offset Correction: v_off_ini = 274.325 uV, v_off_fin = 287.971 uV 15:08:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.984 uVs 15:08:38 Integrated Voltage Measurement... 15:08:47 Voltage Offset Correction: v_off_ini = 277.636 uV, v_off_fin = 262.784 uV 15:08:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.405 uVs 15:08:47 Integrated Voltage Measurement... 15:08:56 Voltage Offset Correction: v_off_ini = 274.408 uV, v_off_fin = 296.680 uV 15:08:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.771 uVs 15:08:56 Integrated Voltage Measurement... 15:09:05 Voltage Offset Correction: v_off_ini = 286.598 uV, v_off_fin = 279.281 uV 15:09:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.804 uVs 15:09:05 Integrated Voltage Measurement... 15:09:14 Voltage Offset Correction: v_off_ini = 290.322 uV, v_off_fin = 299.531 uV 15:09:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.759 uVs 15:09:19 I1Y Average and RMS of Measurements VT = -215.427 +- 4.490 uVs I1Y = -43.086 +- 0.897 uTm 15:09:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:26 Integrated Voltage Measurement... 15:09:35 Voltage Offset Correction: v_off_ini = 273.852 uV, v_off_fin = 277.934 uV 15:09:35 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -30.139 uVs 15:09:35 Integrated Voltage Measurement... 15:09:44 Voltage Offset Correction: v_off_ini = 270.552 uV, v_off_fin = 281.167 uV 15:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.373 uVs 15:09:44 Integrated Voltage Measurement... 15:09:53 Voltage Offset Correction: v_off_ini = 281.404 uV, v_off_fin = 262.090 uV 15:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.589 uVs 15:09:53 Integrated Voltage Measurement... 15:10:02 Voltage Offset Correction: v_off_ini = 266.308 uV, v_off_fin = 283.272 uV 15:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.574 uVs 15:10:02 Integrated Voltage Measurement... 15:10:11 Voltage Offset Correction: v_off_ini = 270.971 uV, v_off_fin = 261.446 uV 15:10:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.267 uVs 15:10:11 Integrated Voltage Measurement... 15:10:20 Voltage Offset Correction: v_off_ini = 269.088 uV, v_off_fin = 289.512 uV 15:10:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.516 uVs 15:10:23 I2X Average and RMS of Measurements VT = -39.910 +- 1.898 uVs I2X = 3.672 +- 0.175 uTm^2 15:10:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:30 Integrated Voltage Measurement... 15:10:39 Voltage Offset Correction: v_off_ini = 275.017 uV, v_off_fin = 284.646 uV 15:10:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.735 uVs 15:10:39 Integrated Voltage Measurement... 15:10:48 Voltage Offset Correction: v_off_ini = 289.823 uV, v_off_fin = 283.468 uV 15:10:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.963 uVs 15:10:48 Integrated Voltage Measurement... 15:10:57 Voltage Offset Correction: v_off_ini = 291.736 uV, v_off_fin = 288.304 uV 15:10:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.036 uVs 15:10:58 Integrated Voltage Measurement... 15:11:06 Voltage Offset Correction: v_off_ini = 274.258 uV, v_off_fin = 277.967 uV 15:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.102 uVs 15:11:07 Integrated Voltage Measurement... 15:11:15 Voltage Offset Correction: v_off_ini = 281.817 uV, v_off_fin = 268.355 uV 15:11:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.300 uVs 15:11:16 Integrated Voltage Measurement... 15:11:25 Voltage Offset Correction: v_off_ini = 271.037 uV, v_off_fin = 276.522 uV 15:11:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.507 uVs 15:11:27 I2Y Average and RMS of Measurements VT = -224.607 +- 8.414 uVs I2Y = -20.664 +- 0.774 uTm^2 15:11:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:11:36 Integrated Voltage Measurement... 15:11:45 Voltage Offset Correction: v_off_ini = 276.683 uV, v_off_fin = 285.616 uV 15:11:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.296 uVs 15:11:45 Integrated Voltage Measurement... 15:11:54 Voltage Offset Correction: v_off_ini = 274.147 uV, v_off_fin = 275.256 uV 15:11:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.969 uVs 15:11:54 Integrated Voltage Measurement... 15:12:03 Voltage Offset Correction: v_off_ini = 274.052 uV, v_off_fin = 277.038 uV 15:12:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.250 uVs 15:12:03 Integrated Voltage Measurement... 15:12:12 Voltage Offset Correction: v_off_ini = 287.823 uV, v_off_fin = 284.001 uV 15:12:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.346 uVs 15:12:12 Integrated Voltage Measurement... 15:12:21 Voltage Offset Correction: v_off_ini = 284.123 uV, v_off_fin = 283.515 uV 15:12:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.550 uVs 15:12:21 Integrated Voltage Measurement... 15:12:30 Voltage Offset Correction: v_off_ini = 284.285 uV, v_off_fin = 275.256 uV 15:12:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.729 uVs 15:12:34 I1X Average and RMS of Measurements VT = -82.023 +- 1.725 uVs I1X = 16.405 +- 0.345 uTm 15:12:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:12:41 Integrated Voltage Measurement... 15:12:50 Voltage Offset Correction: v_off_ini = 288.656 uV, v_off_fin = 278.234 uV 15:12:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.126 uVs 15:12:50 Integrated Voltage Measurement... 15:12:59 Voltage Offset Correction: v_off_ini = 289.632 uV, v_off_fin = 300.020 uV 15:12:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.334 uVs 15:12:59 Integrated Voltage Measurement... 15:13:08 Voltage Offset Correction: v_off_ini = 293.757 uV, v_off_fin = 281.160 uV 15:13:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.858 uVs 15:13:08 Integrated Voltage Measurement... 15:13:17 Voltage Offset Correction: v_off_ini = 293.308 uV, v_off_fin = 303.939 uV 15:13:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.536 uVs 15:13:17 Integrated Voltage Measurement... 15:13:26 Voltage Offset Correction: v_off_ini = 280.464 uV, v_off_fin = 276.238 uV 15:13:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.868 uVs 15:13:26 Integrated Voltage Measurement... 15:13:35 Voltage Offset Correction: v_off_ini = 289.006 uV, v_off_fin = 299.326 uV 15:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.796 uVs 15:13:39 I1Y Average and RMS of Measurements VT = -211.420 +- 0.673 uVs I1Y = -42.284 +- 0.135 uTm 15:13:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:13:47 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 272.179 uV, v_off_fin = 270.819 uV 15:13:56 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -63.882 uVs 15:13:56 Integrated Voltage Measurement... 15:14:05 Voltage Offset Correction: v_off_ini = 284.857 uV, v_off_fin = 296.512 uV 15:14:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.782 uVs 15:14:05 Integrated Voltage Measurement... 15:14:14 Voltage Offset Correction: v_off_ini = 283.190 uV, v_off_fin = 267.991 uV 15:14:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.233 uVs 15:14:14 Integrated Voltage Measurement... 15:14:23 Voltage Offset Correction: v_off_ini = 271.784 uV, v_off_fin = 286.656 uV 15:14:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.660 uVs 15:14:23 Integrated Voltage Measurement... 15:14:32 Voltage Offset Correction: v_off_ini = 274.634 uV, v_off_fin = 270.423 uV 15:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.924 uVs 15:14:32 Integrated Voltage Measurement... 15:14:41 Voltage Offset Correction: v_off_ini = 277.190 uV, v_off_fin = 289.932 uV 15:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.156 uVs 15:14:43 I2X Average and RMS of Measurements VT = -65.940 +- 12.897 uVs I2X = 6.066 +- 1.187 uTm^2 15:14:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:14:51 Integrated Voltage Measurement... 15:15:00 Voltage Offset Correction: v_off_ini = 269.534 uV, v_off_fin = 280.235 uV 15:15:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.715 uVs 15:15:00 Integrated Voltage Measurement... 15:15:09 Voltage Offset Correction: v_off_ini = 271.038 uV, v_off_fin = 268.349 uV 15:15:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.450 uVs 15:15:09 Integrated Voltage Measurement... 15:15:18 Voltage Offset Correction: v_off_ini = 292.225 uV, v_off_fin = 292.154 uV 15:15:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.608 uVs 15:15:18 Integrated Voltage Measurement... 15:15:27 Voltage Offset Correction: v_off_ini = 295.337 uV, v_off_fin = 301.202 uV 15:15:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.009 uVs 15:15:27 Integrated Voltage Measurement... 15:15:36 Voltage Offset Correction: v_off_ini = 306.897 uV, v_off_fin = 303.593 uV 15:15:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -201.147 uVs 15:15:36 Integrated Voltage Measurement... 15:15:45 Voltage Offset Correction: v_off_ini = 300.253 uV, v_off_fin = 297.739 uV 15:15:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.691 uVs 15:15:47 I2Y Average and RMS of Measurements VT = -205.770 +- 4.959 uVs I2Y = -18.931 +- 0.456 uTm^2 15:15:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:15:56 Integrated Voltage Measurement... 15:16:05 Voltage Offset Correction: v_off_ini = 300.545 uV, v_off_fin = 298.214 uV 15:16:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.380 uVs 15:16:05 Integrated Voltage Measurement... 15:16:14 Voltage Offset Correction: v_off_ini = 312.526 uV, v_off_fin = 308.993 uV 15:16:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.978 uVs 15:16:14 Integrated Voltage Measurement... 15:16:23 Voltage Offset Correction: v_off_ini = 301.983 uV, v_off_fin = 308.162 uV 15:16:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.220 uVs 15:16:23 Integrated Voltage Measurement... 15:16:32 Voltage Offset Correction: v_off_ini = 307.806 uV, v_off_fin = 315.229 uV 15:16:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 94.309 uVs 15:16:32 Integrated Voltage Measurement... 15:16:41 Voltage Offset Correction: v_off_ini = 318.147 uV, v_off_fin = 313.030 uV 15:16:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.736 uVs 15:16:41 Integrated Voltage Measurement... 15:16:50 Voltage Offset Correction: v_off_ini = 316.125 uV, v_off_fin = 311.382 uV 15:16:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.477 uVs 15:16:54 I1X Average and RMS of Measurements VT = -103.183 +- 0.707 uVs I1X = 20.638 +- 0.142 uTm 15:16:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:17:01 Integrated Voltage Measurement... 15:17:10 Voltage Offset Correction: v_off_ini = 319.150 uV, v_off_fin = 307.870 uV 15:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.532 uVs 15:17:10 Integrated Voltage Measurement... 15:17:19 Voltage Offset Correction: v_off_ini = 316.128 uV, v_off_fin = 329.486 uV 15:17:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 203.892 uVs 15:17:19 Integrated Voltage Measurement... 15:17:28 Voltage Offset Correction: v_off_ini = 312.454 uV, v_off_fin = 305.744 uV 15:17:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.369 uVs 15:17:28 Integrated Voltage Measurement... 15:17:37 Voltage Offset Correction: v_off_ini = 321.438 uV, v_off_fin = 323.550 uV 15:17:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.840 uVs 15:17:37 Integrated Voltage Measurement... 15:17:46 Voltage Offset Correction: v_off_ini = 323.632 uV, v_off_fin = 311.704 uV 15:17:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -201.191 uVs 15:17:46 Integrated Voltage Measurement... 15:17:55 Voltage Offset Correction: v_off_ini = 311.627 uV, v_off_fin = 336.352 uV 15:17:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.808 uVs 15:17:59 I1Y Average and RMS of Measurements VT = -201.272 +- 2.301 uVs I1Y = -40.256 +- 0.461 uTm 15:18:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:18:07 Integrated Voltage Measurement... 15:18:16 Voltage Offset Correction: v_off_ini = 316.457 uV, v_off_fin = 317.438 uV 15:18:16 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -108.434 uVs 15:18:16 Integrated Voltage Measurement... 15:18:25 Voltage Offset Correction: v_off_ini = 321.855 uV, v_off_fin = 320.493 uV 15:18:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.113 uVs 15:18:25 Integrated Voltage Measurement... 15:18:34 Voltage Offset Correction: v_off_ini = 318.335 uV, v_off_fin = 307.613 uV 15:18:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.614 uVs 15:18:34 Integrated Voltage Measurement... 15:18:43 Voltage Offset Correction: v_off_ini = 301.971 uV, v_off_fin = 312.569 uV 15:18:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.023 uVs 15:18:43 Integrated Voltage Measurement... 15:18:52 Voltage Offset Correction: v_off_ini = 308.776 uV, v_off_fin = 305.576 uV 15:18:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.172 uVs 15:18:52 Integrated Voltage Measurement... 15:19:01 Voltage Offset Correction: v_off_ini = 309.325 uV, v_off_fin = 311.580 uV 15:19:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.349 uVs 15:19:03 I2X Average and RMS of Measurements VT = -93.117 +- 3.447 uVs I2X = 8.566 +- 0.317 uTm^2 15:19:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:19:11 Integrated Voltage Measurement... 15:19:20 Voltage Offset Correction: v_off_ini = 289.078 uV, v_off_fin = 292.005 uV 15:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.988 uVs 15:19:20 Integrated Voltage Measurement... 15:19:29 Voltage Offset Correction: v_off_ini = 296.339 uV, v_off_fin = 282.796 uV 15:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.246 uVs 15:19:29 Integrated Voltage Measurement... 15:19:38 Voltage Offset Correction: v_off_ini = 297.569 uV, v_off_fin = 293.454 uV 15:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.557 uVs 15:19:38 Integrated Voltage Measurement... 15:19:47 Voltage Offset Correction: v_off_ini = 274.821 uV, v_off_fin = 295.843 uV 15:19:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.549 uVs 15:19:47 Integrated Voltage Measurement... 15:19:56 Voltage Offset Correction: v_off_ini = 289.063 uV, v_off_fin = 276.550 uV 15:19:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.715 uVs 15:19:56 Integrated Voltage Measurement... 15:20:05 Voltage Offset Correction: v_off_ini = 295.398 uV, v_off_fin = 279.571 uV 15:20:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.534 uVs 15:20:08 I2Y Average and RMS of Measurements VT = -206.098 +- 2.646 uVs I2Y = -18.961 +- 0.243 uTm^2 15:20:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:20:19 Integrated Voltage Measurement... 15:20:28 Voltage Offset Correction: v_off_ini = 264.505 uV, v_off_fin = 276.274 uV 15:20:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -34.716 uVs 15:20:28 Integrated Voltage Measurement... 15:20:37 Voltage Offset Correction: v_off_ini = 275.270 uV, v_off_fin = 263.057 uV 15:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.675 uVs 15:20:37 Integrated Voltage Measurement... 15:20:46 Voltage Offset Correction: v_off_ini = 271.067 uV, v_off_fin = 266.653 uV 15:20:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.633 uVs 15:20:46 Integrated Voltage Measurement... 15:20:55 Voltage Offset Correction: v_off_ini = 266.298 uV, v_off_fin = 271.313 uV 15:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.616 uVs 15:20:55 Integrated Voltage Measurement... 15:21:04 Voltage Offset Correction: v_off_ini = 274.794 uV, v_off_fin = 273.010 uV 15:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.652 uVs 15:21:04 Integrated Voltage Measurement... 15:21:13 Voltage Offset Correction: v_off_ini = 286.126 uV, v_off_fin = 276.662 uV 15:21:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.188 uVs 15:21:18 I1X Average and RMS of Measurements VT = -45.580 +- 6.041 uVs I1X = 9.116 +- 1.209 uTm 15:21:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:21:24 Integrated Voltage Measurement... 15:21:33 Voltage Offset Correction: v_off_ini = 293.079 uV, v_off_fin = 283.201 uV 15:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.621 uVs 15:21:33 Integrated Voltage Measurement... 15:21:42 Voltage Offset Correction: v_off_ini = 276.264 uV, v_off_fin = 293.589 uV 15:21:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.983 uVs 15:21:42 Integrated Voltage Measurement... 15:21:51 Voltage Offset Correction: v_off_ini = 298.706 uV, v_off_fin = 271.908 uV 15:21:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.362 uVs 15:21:51 Integrated Voltage Measurement... 15:22:00 Voltage Offset Correction: v_off_ini = 284.657 uV, v_off_fin = 287.663 uV 15:22:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.691 uVs 15:22:00 Integrated Voltage Measurement... 15:22:09 Voltage Offset Correction: v_off_ini = 278.364 uV, v_off_fin = 270.839 uV 15:22:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.751 uVs 15:22:09 Integrated Voltage Measurement... 15:22:18 Voltage Offset Correction: v_off_ini = 288.662 uV, v_off_fin = 296.016 uV 15:22:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.277 uVs 15:22:22 I1Y Average and RMS of Measurements VT = -197.947 +- 4.316 uVs I1Y = -39.589 +- 0.863 uTm 15:22:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:22:28 Integrated Voltage Measurement... 15:22:37 Voltage Offset Correction: v_off_ini = 274.915 uV, v_off_fin = 278.631 uV 15:22:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.794 uVs 15:22:37 Integrated Voltage Measurement... 15:22:46 Voltage Offset Correction: v_off_ini = 291.916 uV, v_off_fin = 279.681 uV 15:22:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.506 uVs 15:22:46 Integrated Voltage Measurement... 15:22:55 Voltage Offset Correction: v_off_ini = 283.395 uV, v_off_fin = 273.885 uV 15:22:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -8.172 uVs 15:22:55 Integrated Voltage Measurement... 15:23:04 Voltage Offset Correction: v_off_ini = 287.628 uV, v_off_fin = 306.916 uV 15:23:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.571 uVs 15:23:04 Integrated Voltage Measurement... 15:23:13 Voltage Offset Correction: v_off_ini = 291.465 uV, v_off_fin = 296.510 uV 15:23:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.329 uVs 15:23:13 Integrated Voltage Measurement... 15:23:22 Voltage Offset Correction: v_off_ini = 305.681 uV, v_off_fin = 304.721 uV 15:23:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.952 uVs 15:23:24 I2X Average and RMS of Measurements VT = -24.554 +- 7.054 uVs I2X = 2.259 +- 0.649 uTm^2 15:23:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:23:29 Integrated Voltage Measurement... 15:23:38 Voltage Offset Correction: v_off_ini = 291.766 uV, v_off_fin = 293.716 uV 15:23:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.585 uVs 15:23:38 Integrated Voltage Measurement... 15:23:47 Voltage Offset Correction: v_off_ini = 303.337 uV, v_off_fin = 291.664 uV 15:23:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.771 uVs 15:23:47 Integrated Voltage Measurement... 15:23:56 Voltage Offset Correction: v_off_ini = 291.168 uV, v_off_fin = 301.611 uV 15:23:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.642 uVs 15:23:56 Integrated Voltage Measurement... 15:24:05 Voltage Offset Correction: v_off_ini = 297.520 uV, v_off_fin = 298.886 uV 15:24:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.838 uVs 15:24:05 Integrated Voltage Measurement... 15:24:14 Voltage Offset Correction: v_off_ini = 302.437 uV, v_off_fin = 293.756 uV 15:24:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.890 uVs 15:24:14 Integrated Voltage Measurement... 15:24:23 Voltage Offset Correction: v_off_ini = 301.285 uV, v_off_fin = 300.683 uV 15:24:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.527 uVs 15:24:26 I2Y Average and RMS of Measurements VT = -194.376 +- 6.507 uVs I2Y = -17.883 +- 0.599 uTm^2 15:24:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:24:34 Integrated Voltage Measurement... 15:24:43 Voltage Offset Correction: v_off_ini = 301.537 uV, v_off_fin = 303.521 uV 15:24:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.956 uVs 15:24:43 Integrated Voltage Measurement... 15:24:52 Voltage Offset Correction: v_off_ini = 305.304 uV, v_off_fin = 304.288 uV 15:24:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.797 uVs 15:24:52 Integrated Voltage Measurement... 15:25:01 Voltage Offset Correction: v_off_ini = 308.229 uV, v_off_fin = 306.917 uV 15:25:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.806 uVs 15:25:01 Integrated Voltage Measurement... 15:25:10 Voltage Offset Correction: v_off_ini = 304.599 uV, v_off_fin = 310.956 uV 15:25:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.727 uVs 15:25:10 Integrated Voltage Measurement... 15:25:19 Voltage Offset Correction: v_off_ini = 314.958 uV, v_off_fin = 298.223 uV 15:25:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.728 uVs 15:25:19 Integrated Voltage Measurement... 15:25:28 Voltage Offset Correction: v_off_ini = 316.632 uV, v_off_fin = 312.244 uV 15:25:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.034 uVs 15:25:32 I1X Average and RMS of Measurements VT = -42.341 +- 10.417 uVs I1X = 8.468 +- 2.083 uTm 15:25:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:25:39 Integrated Voltage Measurement... 15:25:48 Voltage Offset Correction: v_off_ini = 320.692 uV, v_off_fin = 302.298 uV 15:25:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.020 uVs 15:25:48 Integrated Voltage Measurement... 15:25:57 Voltage Offset Correction: v_off_ini = 309.528 uV, v_off_fin = 322.799 uV 15:25:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.084 uVs 15:25:57 Integrated Voltage Measurement... 15:26:06 Voltage Offset Correction: v_off_ini = 310.696 uV, v_off_fin = 313.813 uV 15:26:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.491 uVs 15:26:06 Integrated Voltage Measurement... 15:26:15 Voltage Offset Correction: v_off_ini = 304.762 uV, v_off_fin = 320.929 uV 15:26:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.736 uVs 15:26:15 Integrated Voltage Measurement... 15:26:24 Voltage Offset Correction: v_off_ini = 306.852 uV, v_off_fin = 299.526 uV 15:26:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.844 uVs 15:26:24 Integrated Voltage Measurement... 15:26:33 Voltage Offset Correction: v_off_ini = 316.270 uV, v_off_fin = 310.785 uV 15:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.639 uVs 15:26:37 I1Y Average and RMS of Measurements VT = -207.636 +- 4.689 uVs I1Y = -41.527 +- 0.938 uTm 15:26:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:26:42 Integrated Voltage Measurement... 15:26:51 Voltage Offset Correction: v_off_ini = 302.544 uV, v_off_fin = 299.711 uV 15:26:51 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -32.663 uVs 15:26:51 Integrated Voltage Measurement... 15:27:00 Voltage Offset Correction: v_off_ini = 307.318 uV, v_off_fin = 307.646 uV 15:27:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.563 uVs 15:27:00 Integrated Voltage Measurement... 15:27:09 Voltage Offset Correction: v_off_ini = 314.660 uV, v_off_fin = 293.797 uV 15:27:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -26.612 uVs 15:27:09 Integrated Voltage Measurement... 15:27:18 Voltage Offset Correction: v_off_ini = 304.400 uV, v_off_fin = 321.803 uV 15:27:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.265 uVs 15:27:19 Integrated Voltage Measurement... 15:27:28 Voltage Offset Correction: v_off_ini = 314.334 uV, v_off_fin = 298.753 uV 15:27:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.931 uVs 15:27:28 Integrated Voltage Measurement... 15:27:37 Voltage Offset Correction: v_off_ini = 322.191 uV, v_off_fin = 319.173 uV 15:27:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.643 uVs 15:27:39 I2X Average and RMS of Measurements VT = -31.446 +- 6.223 uVs I2X = 2.893 +- 0.572 uTm^2 15:27:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:27:44 Integrated Voltage Measurement... 15:27:53 Voltage Offset Correction: v_off_ini = 312.970 uV, v_off_fin = 305.065 uV 15:27:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.126 uVs 15:27:53 Integrated Voltage Measurement... 15:28:02 Voltage Offset Correction: v_off_ini = 319.075 uV, v_off_fin = 328.031 uV 15:28:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.576 uVs 15:28:02 Integrated Voltage Measurement... 15:28:11 Voltage Offset Correction: v_off_ini = 327.020 uV, v_off_fin = 330.005 uV 15:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.405 uVs 15:28:11 Integrated Voltage Measurement... 15:28:20 Voltage Offset Correction: v_off_ini = 325.557 uV, v_off_fin = 336.911 uV 15:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.332 uVs 15:28:20 Integrated Voltage Measurement... 15:28:29 Voltage Offset Correction: v_off_ini = 344.159 uV, v_off_fin = 338.137 uV 15:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.346 uVs 15:28:29 Integrated Voltage Measurement... 15:28:38 Voltage Offset Correction: v_off_ini = 324.768 uV, v_off_fin = 325.658 uV 15:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.226 uVs 15:28:41 I2Y Average and RMS of Measurements VT = -216.502 +- 8.247 uVs I2Y = -19.918 +- 0.759 uTm^2 15:28:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:49 Integrated Voltage Measurement... 15:28:58 Voltage Offset Correction: v_off_ini = 332.685 uV, v_off_fin = 330.632 uV 15:28:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -59.525 uVs 15:28:58 Integrated Voltage Measurement... 15:29:07 Voltage Offset Correction: v_off_ini = 322.590 uV, v_off_fin = 326.303 uV 15:29:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.516 uVs 15:29:07 Integrated Voltage Measurement... 15:29:16 Voltage Offset Correction: v_off_ini = 323.486 uV, v_off_fin = 321.259 uV 15:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.959 uVs 15:29:16 Integrated Voltage Measurement... 15:29:25 Voltage Offset Correction: v_off_ini = 330.181 uV, v_off_fin = 339.933 uV 15:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 49.716 uVs 15:29:25 Integrated Voltage Measurement... 15:29:34 Voltage Offset Correction: v_off_ini = 322.751 uV, v_off_fin = 335.684 uV 15:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.853 uVs 15:29:34 Integrated Voltage Measurement... 15:29:43 Voltage Offset Correction: v_off_ini = 331.950 uV, v_off_fin = 328.023 uV 15:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.037 uVs 15:29:47 I1X Average and RMS of Measurements VT = -54.768 +- 9.754 uVs I1X = 10.954 +- 1.951 uTm 15:29:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:54 Integrated Voltage Measurement... 15:30:03 Voltage Offset Correction: v_off_ini = 311.885 uV, v_off_fin = 302.086 uV 15:30:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.220 uVs 15:30:03 Integrated Voltage Measurement... 15:30:12 Voltage Offset Correction: v_off_ini = 330.932 uV, v_off_fin = 337.999 uV 15:30:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.198 uVs 15:30:12 Integrated Voltage Measurement... 15:30:21 Voltage Offset Correction: v_off_ini = 335.749 uV, v_off_fin = 319.129 uV 15:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.561 uVs 15:30:21 Integrated Voltage Measurement... 15:30:30 Voltage Offset Correction: v_off_ini = 320.006 uV, v_off_fin = 344.850 uV 15:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.683 uVs 15:30:30 Integrated Voltage Measurement... 15:30:39 Voltage Offset Correction: v_off_ini = 331.724 uV, v_off_fin = 325.114 uV 15:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.778 uVs 15:30:39 Integrated Voltage Measurement... 15:30:48 Voltage Offset Correction: v_off_ini = 343.282 uV, v_off_fin = 346.717 uV 15:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.086 uVs 15:30:52 I1Y Average and RMS of Measurements VT = -217.088 +- 4.259 uVs I1Y = -43.418 +- 0.853 uTm 15:30:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:57 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = 315.624 uV, v_off_fin = 319.777 uV 15:31:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.313 uVs 15:31:06 Integrated Voltage Measurement... 15:31:15 Voltage Offset Correction: v_off_ini = 326.277 uV, v_off_fin = 329.826 uV 15:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.258 uVs 15:31:15 Integrated Voltage Measurement... 15:31:24 Voltage Offset Correction: v_off_ini = 321.141 uV, v_off_fin = 316.814 uV 15:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.917 uVs 15:31:24 Integrated Voltage Measurement... 15:31:33 Voltage Offset Correction: v_off_ini = 308.669 uV, v_off_fin = 318.674 uV 15:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.933 uVs 15:31:33 Integrated Voltage Measurement... 15:31:42 Voltage Offset Correction: v_off_ini = 310.044 uV, v_off_fin = 298.827 uV 15:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.523 uVs 15:31:42 Integrated Voltage Measurement... 15:31:51 Voltage Offset Correction: v_off_ini = 300.548 uV, v_off_fin = 308.237 uV 15:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.292 uVs 15:31:54 I2X Average and RMS of Measurements VT = -39.873 +- 3.723 uVs I2X = 3.668 +- 0.343 uTm^2 15:31:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:59 Integrated Voltage Measurement... 15:32:08 Voltage Offset Correction: v_off_ini = 296.309 uV, v_off_fin = 303.638 uV 15:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.380 uVs 15:32:08 Integrated Voltage Measurement... 15:32:17 Voltage Offset Correction: v_off_ini = 305.480 uV, v_off_fin = 300.401 uV 15:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.353 uVs 15:32:17 Integrated Voltage Measurement... 15:32:26 Voltage Offset Correction: v_off_ini = 309.979 uV, v_off_fin = 298.869 uV 15:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.115 uVs 15:32:26 Integrated Voltage Measurement... 15:32:35 Voltage Offset Correction: v_off_ini = 298.224 uV, v_off_fin = 308.239 uV 15:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.777 uVs 15:32:35 Integrated Voltage Measurement... 15:32:44 Voltage Offset Correction: v_off_ini = 311.717 uV, v_off_fin = 308.025 uV 15:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.950 uVs 15:32:44 Integrated Voltage Measurement... 15:32:53 Voltage Offset Correction: v_off_ini = 313.397 uV, v_off_fin = 306.029 uV 15:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.623 uVs 15:32:56 I2Y Average and RMS of Measurements VT = -225.366 +- 7.762 uVs I2Y = -20.734 +- 0.714 uTm^2 15:33:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:33:04 Integrated Voltage Measurement... 15:33:13 Voltage Offset Correction: v_off_ini = 317.256 uV, v_off_fin = 315.360 uV 15:33:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.443 uVs 15:33:13 Integrated Voltage Measurement... 15:33:22 Voltage Offset Correction: v_off_ini = 316.894 uV, v_off_fin = 318.816 uV 15:33:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.345 uVs 15:33:22 Integrated Voltage Measurement... 15:33:31 Voltage Offset Correction: v_off_ini = 309.081 uV, v_off_fin = 309.704 uV 15:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.794 uVs 15:33:31 Integrated Voltage Measurement... 15:33:40 Voltage Offset Correction: v_off_ini = 321.627 uV, v_off_fin = 303.857 uV 15:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.938 uVs 15:33:40 Integrated Voltage Measurement... 15:33:49 Voltage Offset Correction: v_off_ini = 290.276 uV, v_off_fin = 310.171 uV 15:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.853 uVs 15:33:49 Integrated Voltage Measurement... 15:33:58 Voltage Offset Correction: v_off_ini = 308.893 uV, v_off_fin = 301.212 uV 15:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.875 uVs 15:34:02 I1X Average and RMS of Measurements VT = -58.041 +- 6.421 uVs I1X = 11.608 +- 1.284 uTm 15:34:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:34:09 Integrated Voltage Measurement... 15:34:18 Voltage Offset Correction: v_off_ini = 295.204 uV, v_off_fin = 301.709 uV 15:34:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.474 uVs 15:34:18 Integrated Voltage Measurement... 15:34:27 Voltage Offset Correction: v_off_ini = 309.281 uV, v_off_fin = 299.208 uV 15:34:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.862 uVs 15:34:27 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = 299.569 uV, v_off_fin = 281.115 uV 15:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.100 uVs 15:34:36 Integrated Voltage Measurement... 15:34:45 Voltage Offset Correction: v_off_ini = 295.083 uV, v_off_fin = 314.492 uV 15:34:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.710 uVs 15:34:45 Integrated Voltage Measurement... 15:34:54 Voltage Offset Correction: v_off_ini = 301.348 uV, v_off_fin = 302.533 uV 15:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.661 uVs 15:34:54 Integrated Voltage Measurement... 15:35:03 Voltage Offset Correction: v_off_ini = 306.778 uV, v_off_fin = 324.512 uV 15:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.630 uVs 15:35:07 I1Y Average and RMS of Measurements VT = -228.740 +- 8.983 uVs I1Y = -45.748 +- 1.797 uTm 15:35:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:35:12 Integrated Voltage Measurement... 15:35:21 Voltage Offset Correction: v_off_ini = 301.154 uV, v_off_fin = 298.738 uV 15:35:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.677 uVs 15:35:21 Integrated Voltage Measurement... 15:35:30 Voltage Offset Correction: v_off_ini = 320.449 uV, v_off_fin = 319.390 uV 15:35:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.615 uVs 15:35:30 Integrated Voltage Measurement... 15:35:39 Voltage Offset Correction: v_off_ini = 320.944 uV, v_off_fin = 320.479 uV 15:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.088 uVs 15:35:39 Integrated Voltage Measurement... 15:35:48 Voltage Offset Correction: v_off_ini = 324.983 uV, v_off_fin = 324.617 uV 15:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.617 uVs 15:35:48 Integrated Voltage Measurement... 15:35:57 Voltage Offset Correction: v_off_ini = 312.113 uV, v_off_fin = 314.042 uV 15:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.445 uVs 15:35:57 Integrated Voltage Measurement... 15:36:06 Voltage Offset Correction: v_off_ini = 327.641 uV, v_off_fin = 328.652 uV 15:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.707 uVs 15:36:09 I2X Average and RMS of Measurements VT = -39.358 +- 10.829 uVs I2X = 3.621 +- 0.996 uTm^2 15:36:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:36:14 Integrated Voltage Measurement... 15:36:23 Voltage Offset Correction: v_off_ini = 325.397 uV, v_off_fin = 334.215 uV 15:36:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.877 uVs 15:36:23 Integrated Voltage Measurement... 15:36:32 Voltage Offset Correction: v_off_ini = 321.812 uV, v_off_fin = 330.249 uV 15:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.591 uVs 15:36:32 Integrated Voltage Measurement... 15:36:41 Voltage Offset Correction: v_off_ini = 329.686 uV, v_off_fin = 330.211 uV 15:36:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -228.837 uVs 15:36:41 Integrated Voltage Measurement... 15:36:50 Voltage Offset Correction: v_off_ini = 330.575 uV, v_off_fin = 338.630 uV 15:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.745 uVs 15:36:50 Integrated Voltage Measurement... 15:36:59 Voltage Offset Correction: v_off_ini = 325.298 uV, v_off_fin = 322.092 uV 15:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.759 uVs 15:36:59 Integrated Voltage Measurement... 15:37:08 Voltage Offset Correction: v_off_ini = 329.330 uV, v_off_fin = 335.391 uV 15:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.285 uVs 15:37:11 I2Y Average and RMS of Measurements VT = -230.182 +- 4.270 uVs I2Y = -21.177 +- 0.392 uTm^2 15:37:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:37:19 Integrated Voltage Measurement... 15:37:28 Voltage Offset Correction: v_off_ini = 338.007 uV, v_off_fin = 327.622 uV 15:37:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.244 uVs 15:37:28 Integrated Voltage Measurement... 15:37:37 Voltage Offset Correction: v_off_ini = 323.436 uV, v_off_fin = 319.106 uV 15:37:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.719 uVs 15:37:37 Integrated Voltage Measurement... 15:37:46 Voltage Offset Correction: v_off_ini = 325.339 uV, v_off_fin = 313.861 uV 15:37:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.447 uVs 15:37:46 Integrated Voltage Measurement... 15:37:55 Voltage Offset Correction: v_off_ini = 319.542 uV, v_off_fin = 320.538 uV 15:37:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.107 uVs 15:37:55 Integrated Voltage Measurement... 15:38:04 Voltage Offset Correction: v_off_ini = 330.431 uV, v_off_fin = 326.095 uV 15:38:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.598 uVs 15:38:04 Integrated Voltage Measurement... 15:38:13 Voltage Offset Correction: v_off_ini = 343.186 uV, v_off_fin = 324.205 uV 15:38:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.020 uVs 15:38:17 I1X Average and RMS of Measurements VT = -60.856 +- 6.772 uVs I1X = 12.171 +- 1.354 uTm 15:38:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:38:24 Integrated Voltage Measurement... 15:38:33 Voltage Offset Correction: v_off_ini = 317.046 uV, v_off_fin = 304.773 uV 15:38:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.530 uVs 15:38:33 Integrated Voltage Measurement... 15:38:42 Voltage Offset Correction: v_off_ini = 342.312 uV, v_off_fin = 349.104 uV 15:38:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.432 uVs 15:38:42 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = 330.844 uV, v_off_fin = 315.497 uV 15:38:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.063 uVs 15:38:51 Integrated Voltage Measurement... 15:39:00 Voltage Offset Correction: v_off_ini = 332.280 uV, v_off_fin = 343.062 uV 15:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.408 uVs 15:39:00 Integrated Voltage Measurement... 15:39:09 Voltage Offset Correction: v_off_ini = 329.820 uV, v_off_fin = 324.556 uV 15:39:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.699 uVs 15:39:09 Integrated Voltage Measurement... 15:39:18 Voltage Offset Correction: v_off_ini = 335.547 uV, v_off_fin = 346.775 uV 15:39:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.821 uVs 15:39:22 I1Y Average and RMS of Measurements VT = -223.492 +- 5.890 uVs I1Y = -44.699 +- 1.177 uTm 15:39:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:39:27 Integrated Voltage Measurement... 15:39:36 Voltage Offset Correction: v_off_ini = 329.833 uV, v_off_fin = 325.418 uV 15:39:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.883 uVs 15:39:36 Integrated Voltage Measurement... 15:39:45 Voltage Offset Correction: v_off_ini = 340.928 uV, v_off_fin = 332.653 uV 15:39:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.281 uVs 15:39:45 Integrated Voltage Measurement... 15:39:54 Voltage Offset Correction: v_off_ini = 335.328 uV, v_off_fin = 329.346 uV 15:39:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.957 uVs 15:39:54 Integrated Voltage Measurement... 15:40:03 Voltage Offset Correction: v_off_ini = 334.174 uV, v_off_fin = 344.070 uV 15:40:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.817 uVs 15:40:03 Integrated Voltage Measurement... 15:40:12 Voltage Offset Correction: v_off_ini = 337.895 uV, v_off_fin = 333.126 uV 15:40:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.400 uVs 15:40:12 Integrated Voltage Measurement... 15:40:21 Voltage Offset Correction: v_off_ini = 339.760 uV, v_off_fin = 339.621 uV 15:40:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.270 uVs 15:40:24 I2X Average and RMS of Measurements VT = -43.101 +- 7.582 uVs I2X = 3.965 +- 0.698 uTm^2 15:40:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:40:29 Integrated Voltage Measurement... 15:40:38 Voltage Offset Correction: v_off_ini = 331.268 uV, v_off_fin = 324.654 uV 15:40:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.227 uVs 15:40:38 Integrated Voltage Measurement... 15:40:47 Voltage Offset Correction: v_off_ini = 334.441 uV, v_off_fin = 337.889 uV 15:40:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.339 uVs 15:40:47 Integrated Voltage Measurement... 15:40:56 Voltage Offset Correction: v_off_ini = 341.378 uV, v_off_fin = 333.368 uV 15:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.506 uVs 15:40:56 Integrated Voltage Measurement... 15:41:05 Voltage Offset Correction: v_off_ini = 342.908 uV, v_off_fin = 354.829 uV 15:41:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.901 uVs 15:41:05 Integrated Voltage Measurement... 15:41:14 Voltage Offset Correction: v_off_ini = 343.492 uV, v_off_fin = 350.290 uV 15:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.894 uVs 15:41:14 Integrated Voltage Measurement... 15:41:23 Voltage Offset Correction: v_off_ini = 347.919 uV, v_off_fin = 347.128 uV 15:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.193 uVs 15:41:25 I2Y Average and RMS of Measurements VT = -244.343 +- 2.713 uVs I2Y = -22.480 +- 0.250 uTm^2 15:41:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:41:46 Integrated Voltage Measurement... 15:41:54 Voltage Offset Correction: v_off_ini = 396.903 uV, v_off_fin = 390.334 uV 15:41:55 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -33.474 uVs 15:41:55 Integrated Voltage Measurement... 15:42:04 Voltage Offset Correction: v_off_ini = 392.211 uV, v_off_fin = 398.918 uV 15:42:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.721 uVs 15:42:04 Integrated Voltage Measurement... 15:42:13 Voltage Offset Correction: v_off_ini = 401.966 uV, v_off_fin = 391.480 uV 15:42:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -19.227 uVs 15:42:13 Integrated Voltage Measurement... 15:42:22 Voltage Offset Correction: v_off_ini = 390.603 uV, v_off_fin = 383.393 uV 15:42:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.277 uVs 15:42:22 Integrated Voltage Measurement... 15:42:31 Voltage Offset Correction: v_off_ini = 394.819 uV, v_off_fin = 380.261 uV 15:42:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.239 uVs 15:42:31 Integrated Voltage Measurement... 15:42:40 Voltage Offset Correction: v_off_ini = 376.370 uV, v_off_fin = 390.698 uV 15:42:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.710 uVs 15:42:44 I1X Average and RMS of Measurements VT = -28.274 +- 1.717 uVs I1X = 5.655 +- 0.344 uTm 15:42:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:42:51 Integrated Voltage Measurement... 15:43:00 Voltage Offset Correction: v_off_ini = 388.143 uV, v_off_fin = 378.804 uV 15:43:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.242 uVs 15:43:00 Integrated Voltage Measurement... 15:43:09 Voltage Offset Correction: v_off_ini = 380.895 uV, v_off_fin = 386.477 uV 15:43:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.194 uVs 15:43:09 Integrated Voltage Measurement... 15:43:18 Voltage Offset Correction: v_off_ini = 379.530 uV, v_off_fin = 368.353 uV 15:43:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.657 uVs 15:43:18 Integrated Voltage Measurement... 15:43:27 Voltage Offset Correction: v_off_ini = 375.437 uV, v_off_fin = 393.777 uV 15:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.199 uVs 15:43:27 Integrated Voltage Measurement... 15:43:36 Voltage Offset Correction: v_off_ini = 383.797 uV, v_off_fin = 374.673 uV 15:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.405 uVs 15:43:36 Integrated Voltage Measurement... 15:43:45 Voltage Offset Correction: v_off_ini = 383.536 uV, v_off_fin = 395.947 uV 15:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.675 uVs 15:43:49 I1Y Average and RMS of Measurements VT = -245.895 +- 7.177 uVs I1Y = -49.179 +- 1.435 uTm 15:43:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:43:56 Integrated Voltage Measurement... 15:44:05 Voltage Offset Correction: v_off_ini = 385.448 uV, v_off_fin = 384.044 uV 15:44:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.405 uVs 15:44:06 Integrated Voltage Measurement... 15:44:15 Voltage Offset Correction: v_off_ini = 389.983 uV, v_off_fin = 396.187 uV 15:44:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 7.773 uVs 15:44:15 Integrated Voltage Measurement... 15:44:24 Voltage Offset Correction: v_off_ini = 387.919 uV, v_off_fin = 379.346 uV 15:44:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.546 uVs 15:44:24 Integrated Voltage Measurement... 15:44:33 Voltage Offset Correction: v_off_ini = 393.825 uV, v_off_fin = 402.849 uV 15:44:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 9.911 uVs 15:44:33 Integrated Voltage Measurement... 15:44:42 Voltage Offset Correction: v_off_ini = 403.708 uV, v_off_fin = 392.850 uV 15:44:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.678 uVs 15:44:42 Integrated Voltage Measurement... 15:44:51 Voltage Offset Correction: v_off_ini = 401.231 uV, v_off_fin = 400.779 uV 15:44:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.241 uVs 15:44:53 I2X Average and RMS of Measurements VT = -17.593 +- 0.998 uVs I2X = 1.619 +- 0.092 uTm^2 15:44:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:45:01 Integrated Voltage Measurement... 15:45:10 Voltage Offset Correction: v_off_ini = 393.313 uV, v_off_fin = 383.734 uV 15:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.024 uVs 15:45:10 Integrated Voltage Measurement... 15:45:19 Voltage Offset Correction: v_off_ini = 395.726 uV, v_off_fin = 395.497 uV 15:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.458 uVs 15:45:19 Integrated Voltage Measurement... 15:45:28 Voltage Offset Correction: v_off_ini = 392.674 uV, v_off_fin = 388.261 uV 15:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.407 uVs 15:45:28 Integrated Voltage Measurement... 15:45:37 Voltage Offset Correction: v_off_ini = 387.700 uV, v_off_fin = 398.092 uV 15:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.688 uVs 15:45:37 Integrated Voltage Measurement... 15:45:46 Voltage Offset Correction: v_off_ini = 395.263 uV, v_off_fin = 380.134 uV 15:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.027 uVs 15:45:46 Integrated Voltage Measurement... 15:45:55 Voltage Offset Correction: v_off_ini = 389.660 uV, v_off_fin = 394.447 uV 15:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.456 uVs 15:45:57 I2Y Average and RMS of Measurements VT = -242.510 +- 5.127 uVs I2Y = -22.311 +- 0.472 uTm^2 15:46:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:46:06 Integrated Voltage Measurement... 15:46:15 Voltage Offset Correction: v_off_ini = 399.379 uV, v_off_fin = 401.939 uV 15:46:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -53.447 uVs 15:46:15 Integrated Voltage Measurement... 15:46:24 Voltage Offset Correction: v_off_ini = 403.273 uV, v_off_fin = 405.654 uV 15:46:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 63.344 uVs 15:46:24 Integrated Voltage Measurement... 15:46:33 Voltage Offset Correction: v_off_ini = 392.654 uV, v_off_fin = 398.307 uV 15:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.178 uVs 15:46:33 Integrated Voltage Measurement... 15:46:42 Voltage Offset Correction: v_off_ini = 400.898 uV, v_off_fin = 395.596 uV 15:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.622 uVs 15:46:42 Integrated Voltage Measurement... 15:46:51 Voltage Offset Correction: v_off_ini = 394.646 uV, v_off_fin = 387.449 uV 15:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.729 uVs 15:46:51 Integrated Voltage Measurement... 15:47:00 Voltage Offset Correction: v_off_ini = 382.734 uV, v_off_fin = 391.964 uV 15:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.162 uVs 15:47:05 I1X Average and RMS of Measurements VT = -53.414 +- 3.523 uVs I1X = 10.683 +- 0.705 uTm 15:47:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 396.409 uV, v_off_fin = 382.261 uV 15:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.799 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 389.506 uV, v_off_fin = 404.409 uV 15:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.402 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 385.571 uV, v_off_fin = 382.459 uV 15:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.501 uVs 15:47:38 Integrated Voltage Measurement... 15:47:47 Voltage Offset Correction: v_off_ini = 394.250 uV, v_off_fin = 393.119 uV 15:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.568 uVs 15:47:47 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = 391.313 uV, v_off_fin = 384.391 uV 15:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.746 uVs 15:47:56 Integrated Voltage Measurement... 15:48:05 Voltage Offset Correction: v_off_ini = 392.747 uV, v_off_fin = 400.854 uV 15:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.499 uVs 15:48:09 I1Y Average and RMS of Measurements VT = -222.086 +- 4.110 uVs I1Y = -44.417 +- 0.822 uTm 15:48:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:48:17 Integrated Voltage Measurement... 15:48:26 Voltage Offset Correction: v_off_ini = 381.738 uV, v_off_fin = 391.146 uV 15:48:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.869 uVs 15:48:26 Integrated Voltage Measurement... 15:48:35 Voltage Offset Correction: v_off_ini = 387.624 uV, v_off_fin = 396.247 uV 15:48:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.262 uVs 15:48:35 Integrated Voltage Measurement... 15:48:44 Voltage Offset Correction: v_off_ini = 396.384 uV, v_off_fin = 396.982 uV 15:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.984 uVs 15:48:44 Integrated Voltage Measurement... 15:48:53 Voltage Offset Correction: v_off_ini = 394.634 uV, v_off_fin = 397.003 uV 15:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.227 uVs 15:48:53 Integrated Voltage Measurement... 15:49:02 Voltage Offset Correction: v_off_ini = 391.459 uV, v_off_fin = 399.869 uV 15:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.910 uVs 15:49:02 Integrated Voltage Measurement... 15:49:11 Voltage Offset Correction: v_off_ini = 392.376 uV, v_off_fin = 405.604 uV 15:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.847 uVs 15:49:14 I2X Average and RMS of Measurements VT = -41.017 +- 3.984 uVs I2X = 3.774 +- 0.367 uTm^2 15:49:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:49:21 Integrated Voltage Measurement... 15:49:30 Voltage Offset Correction: v_off_ini = 412.152 uV, v_off_fin = 400.939 uV 15:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.734 uVs 15:49:31 Integrated Voltage Measurement... 15:49:39 Voltage Offset Correction: v_off_ini = 400.483 uV, v_off_fin = 408.895 uV 15:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.997 uVs 15:49:40 Integrated Voltage Measurement... 15:49:49 Voltage Offset Correction: v_off_ini = 402.205 uV, v_off_fin = 396.833 uV 15:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.442 uVs 15:49:49 Integrated Voltage Measurement... 15:49:58 Voltage Offset Correction: v_off_ini = 399.233 uV, v_off_fin = 399.572 uV 15:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.334 uVs 15:49:58 Integrated Voltage Measurement... 15:50:07 Voltage Offset Correction: v_off_ini = 400.639 uV, v_off_fin = 393.843 uV 15:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.166 uVs 15:50:07 Integrated Voltage Measurement... 15:50:16 Voltage Offset Correction: v_off_ini = 391.550 uV, v_off_fin = 401.426 uV 15:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.018 uVs 15:50:18 I2Y Average and RMS of Measurements VT = -223.282 +- 5.238 uVs I2Y = -20.542 +- 0.482 uTm^2 15:50:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:27 Integrated Voltage Measurement... 15:50:36 Voltage Offset Correction: v_off_ini = 407.185 uV, v_off_fin = 398.733 uV 15:50:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.886 uVs 15:50:36 Integrated Voltage Measurement... 15:50:45 Voltage Offset Correction: v_off_ini = 410.069 uV, v_off_fin = 412.000 uV 15:50:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.557 uVs 15:50:45 Integrated Voltage Measurement... 15:50:54 Voltage Offset Correction: v_off_ini = 401.965 uV, v_off_fin = 410.030 uV 15:50:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.953 uVs 15:50:54 Integrated Voltage Measurement... 15:51:03 Voltage Offset Correction: v_off_ini = 418.960 uV, v_off_fin = 411.205 uV 15:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.124 uVs 15:51:03 Integrated Voltage Measurement... 15:51:12 Voltage Offset Correction: v_off_ini = 406.327 uV, v_off_fin = 400.285 uV 15:51:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.799 uVs 15:51:12 Integrated Voltage Measurement... 15:51:21 Voltage Offset Correction: v_off_ini = 420.469 uV, v_off_fin = 403.680 uV 15:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.463 uVs 15:51:25 I1X Average and RMS of Measurements VT = -57.130 +- 9.305 uVs I1X = 11.426 +- 1.861 uTm 15:51:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:32 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = 409.823 uV, v_off_fin = 401.656 uV 15:51:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.420 uVs 15:51:41 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = 412.815 uV, v_off_fin = 423.142 uV 15:51:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.267 uVs 15:51:50 Integrated Voltage Measurement... 15:51:59 Voltage Offset Correction: v_off_ini = 403.610 uV, v_off_fin = 382.726 uV 15:51:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.239 uVs 15:51:59 Integrated Voltage Measurement... 15:52:08 Voltage Offset Correction: v_off_ini = 394.729 uV, v_off_fin = 414.377 uV 15:52:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.331 uVs 15:52:08 Integrated Voltage Measurement... 15:52:17 Voltage Offset Correction: v_off_ini = 396.739 uV, v_off_fin = 401.211 uV 15:52:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.246 uVs 15:52:17 Integrated Voltage Measurement... 15:52:26 Voltage Offset Correction: v_off_ini = 412.502 uV, v_off_fin = 412.600 uV 15:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.872 uVs 15:52:30 I1Y Average and RMS of Measurements VT = -221.563 +- 0.869 uVs I1Y = -44.313 +- 0.174 uTm 15:52:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:38 Integrated Voltage Measurement... 15:52:47 Voltage Offset Correction: v_off_ini = 412.925 uV, v_off_fin = 411.803 uV 15:52:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.561 uVs 15:52:47 Integrated Voltage Measurement... 15:52:56 Voltage Offset Correction: v_off_ini = 415.688 uV, v_off_fin = 419.084 uV 15:52:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.305 uVs 15:52:56 Integrated Voltage Measurement... 15:53:05 Voltage Offset Correction: v_off_ini = 414.363 uV, v_off_fin = 408.689 uV 15:53:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.184 uVs 15:53:05 Integrated Voltage Measurement... 15:53:14 Voltage Offset Correction: v_off_ini = 414.833 uV, v_off_fin = 426.120 uV 15:53:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.927 uVs 15:53:14 Integrated Voltage Measurement... 15:53:23 Voltage Offset Correction: v_off_ini = 423.773 uV, v_off_fin = 407.611 uV 15:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.710 uVs 15:53:23 Integrated Voltage Measurement... 15:53:32 Voltage Offset Correction: v_off_ini = 422.921 uV, v_off_fin = 418.199 uV 15:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.761 uVs 15:53:34 I2X Average and RMS of Measurements VT = -49.908 +- 3.559 uVs I2X = 4.592 +- 0.327 uTm^2 15:53:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:42 Integrated Voltage Measurement... 15:53:51 Voltage Offset Correction: v_off_ini = 410.727 uV, v_off_fin = 415.381 uV 15:53:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.278 uVs 15:53:51 Integrated Voltage Measurement... 15:54:00 Voltage Offset Correction: v_off_ini = 400.898 uV, v_off_fin = 421.175 uV 15:54:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.806 uVs 15:54:00 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = 411.950 uV, v_off_fin = 394.751 uV 15:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.617 uVs 15:54:09 Integrated Voltage Measurement... 15:54:18 Voltage Offset Correction: v_off_ini = 403.972 uV, v_off_fin = 409.865 uV 15:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.881 uVs 15:54:18 Integrated Voltage Measurement... 15:54:27 Voltage Offset Correction: v_off_ini = 407.676 uV, v_off_fin = 395.354 uV 15:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.513 uVs 15:54:27 Integrated Voltage Measurement... 15:54:36 Voltage Offset Correction: v_off_ini = 392.664 uV, v_off_fin = 402.365 uV 15:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.797 uVs 15:54:39 I2Y Average and RMS of Measurements VT = -229.315 +- 4.560 uVs I2Y = -21.097 +- 0.420 uTm^2 15:54:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:54:48 Integrated Voltage Measurement... 15:54:57 Voltage Offset Correction: v_off_ini = 418.799 uV, v_off_fin = 405.550 uV 15:54:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.387 uVs 15:54:57 Integrated Voltage Measurement... 15:55:06 Voltage Offset Correction: v_off_ini = 404.022 uV, v_off_fin = 403.600 uV 15:55:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.309 uVs 15:55:06 Integrated Voltage Measurement... 15:55:15 Voltage Offset Correction: v_off_ini = 398.403 uV, v_off_fin = 401.187 uV 15:55:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.454 uVs 15:55:15 Integrated Voltage Measurement... 15:55:24 Voltage Offset Correction: v_off_ini = 399.901 uV, v_off_fin = 397.341 uV 15:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.345 uVs 15:55:24 Integrated Voltage Measurement... 15:55:33 Voltage Offset Correction: v_off_ini = 401.417 uV, v_off_fin = 399.801 uV 15:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.731 uVs 15:55:33 Integrated Voltage Measurement... 15:55:42 Voltage Offset Correction: v_off_ini = 405.195 uV, v_off_fin = 416.291 uV 15:55:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.832 uVs 15:55:46 I1X Average and RMS of Measurements VT = -81.177 +- 11.163 uVs I1X = 16.236 +- 2.233 uTm 15:55:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:55:53 Integrated Voltage Measurement... 15:56:02 Voltage Offset Correction: v_off_ini = 396.334 uV, v_off_fin = 386.667 uV 15:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.625 uVs 15:56:02 Integrated Voltage Measurement... 15:56:11 Voltage Offset Correction: v_off_ini = 390.371 uV, v_off_fin = 407.556 uV 15:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.090 uVs 15:56:11 Integrated Voltage Measurement... 15:56:20 Voltage Offset Correction: v_off_ini = 399.312 uV, v_off_fin = 396.834 uV 15:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.286 uVs 15:56:20 Integrated Voltage Measurement... 15:56:29 Voltage Offset Correction: v_off_ini = 393.263 uV, v_off_fin = 403.567 uV 15:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.219 uVs 15:56:29 Integrated Voltage Measurement... 15:56:38 Voltage Offset Correction: v_off_ini = 391.763 uV, v_off_fin = 384.152 uV 15:56:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.848 uVs 15:56:38 Integrated Voltage Measurement... 15:56:47 Voltage Offset Correction: v_off_ini = 398.945 uV, v_off_fin = 409.541 uV 15:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.814 uVs 15:56:51 I1Y Average and RMS of Measurements VT = -204.480 +- 2.997 uVs I1Y = -40.896 +- 0.599 uTm 15:56:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:56:59 Integrated Voltage Measurement... 15:57:08 Voltage Offset Correction: v_off_ini = 412.161 uV, v_off_fin = 404.093 uV 15:57:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.164 uVs 15:57:08 Integrated Voltage Measurement... 15:57:17 Voltage Offset Correction: v_off_ini = 410.923 uV, v_off_fin = 422.511 uV 15:57:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.983 uVs 15:57:17 Integrated Voltage Measurement... 15:57:26 Voltage Offset Correction: v_off_ini = 405.978 uV, v_off_fin = 401.643 uV 15:57:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.158 uVs 15:57:26 Integrated Voltage Measurement... 15:57:35 Voltage Offset Correction: v_off_ini = 421.796 uV, v_off_fin = 419.592 uV 15:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.473 uVs 15:57:35 Integrated Voltage Measurement... 15:57:44 Voltage Offset Correction: v_off_ini = 407.810 uV, v_off_fin = 408.117 uV 15:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.417 uVs 15:57:44 Integrated Voltage Measurement... 15:57:53 Voltage Offset Correction: v_off_ini = 415.429 uV, v_off_fin = 418.485 uV 15:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.114 uVs 15:57:55 I2X Average and RMS of Measurements VT = -70.551 +- 8.561 uVs I2X = 6.491 +- 0.788 uTm^2 15:58:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:58:03 Integrated Voltage Measurement... 15:58:12 Voltage Offset Correction: v_off_ini = 415.029 uV, v_off_fin = 411.082 uV 15:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.385 uVs 15:58:12 Integrated Voltage Measurement... 15:58:21 Voltage Offset Correction: v_off_ini = 398.852 uV, v_off_fin = 407.124 uV 15:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.351 uVs 15:58:21 Integrated Voltage Measurement... 15:58:30 Voltage Offset Correction: v_off_ini = 411.097 uV, v_off_fin = 408.812 uV 15:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.130 uVs 15:58:30 Integrated Voltage Measurement... 15:58:39 Voltage Offset Correction: v_off_ini = 413.696 uV, v_off_fin = 411.160 uV 15:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.030 uVs 15:58:39 Integrated Voltage Measurement... 15:58:48 Voltage Offset Correction: v_off_ini = 415.739 uV, v_off_fin = 411.622 uV 15:58:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.350 uVs 15:58:48 Integrated Voltage Measurement... 15:58:57 Voltage Offset Correction: v_off_ini = 417.493 uV, v_off_fin = 419.281 uV 15:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.646 uVs 15:58:59 I2Y Average and RMS of Measurements VT = -209.982 +- 11.423 uVs I2Y = -19.318 +- 1.051 uTm^2 15:59:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:59:08 Integrated Voltage Measurement... 15:59:17 Voltage Offset Correction: v_off_ini = 403.510 uV, v_off_fin = 400.026 uV 15:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.781 uVs 15:59:17 Integrated Voltage Measurement... 15:59:26 Voltage Offset Correction: v_off_ini = 419.822 uV, v_off_fin = 400.623 uV 15:59:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.648 uVs 15:59:26 Integrated Voltage Measurement... 15:59:35 Voltage Offset Correction: v_off_ini = 407.299 uV, v_off_fin = 399.592 uV 15:59:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.176 uVs 15:59:35 Integrated Voltage Measurement... 15:59:44 Voltage Offset Correction: v_off_ini = 397.799 uV, v_off_fin = 394.867 uV 15:59:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 89.150 uVs 15:59:44 Integrated Voltage Measurement... 15:59:53 Voltage Offset Correction: v_off_ini = 401.661 uV, v_off_fin = 385.905 uV 15:59:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.076 uVs 15:59:53 Integrated Voltage Measurement... 16:00:02 Voltage Offset Correction: v_off_ini = 400.620 uV, v_off_fin = 403.386 uV 16:00:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.707 uVs 16:00:07 I1X Average and RMS of Measurements VT = -95.090 +- 1.638 uVs I1X = 19.019 +- 0.327 uTm 16:00:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:00:13 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = 393.093 uV, v_off_fin = 386.498 uV 16:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.965 uVs 16:00:22 Integrated Voltage Measurement... 16:00:31 Voltage Offset Correction: v_off_ini = 398.849 uV, v_off_fin = 413.744 uV 16:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.162 uVs 16:00:31 Integrated Voltage Measurement... 16:00:40 Voltage Offset Correction: v_off_ini = 400.862 uV, v_off_fin = 391.856 uV 16:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.789 uVs 16:00:40 Integrated Voltage Measurement... 16:00:49 Voltage Offset Correction: v_off_ini = 390.465 uV, v_off_fin = 409.282 uV 16:00:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.652 uVs 16:00:49 Integrated Voltage Measurement... 16:00:58 Voltage Offset Correction: v_off_ini = 405.125 uV, v_off_fin = 387.516 uV 16:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.074 uVs 16:00:58 Integrated Voltage Measurement... 16:01:07 Voltage Offset Correction: v_off_ini = 399.564 uV, v_off_fin = 413.551 uV 16:01:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.143 uVs 16:01:12 I1Y Average and RMS of Measurements VT = -206.631 +- 3.676 uVs I1Y = -41.326 +- 0.735 uTm 16:01:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:01:19 Integrated Voltage Measurement... 16:01:28 Voltage Offset Correction: v_off_ini = 399.870 uV, v_off_fin = 399.628 uV 16:01:28 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -90.680 uVs 16:01:28 Integrated Voltage Measurement... 16:01:37 Voltage Offset Correction: v_off_ini = 410.674 uV, v_off_fin = 409.764 uV 16:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.284 uVs 16:01:37 Integrated Voltage Measurement... 16:01:46 Voltage Offset Correction: v_off_ini = 419.518 uV, v_off_fin = 413.580 uV 16:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.880 uVs 16:01:46 Integrated Voltage Measurement... 16:01:55 Voltage Offset Correction: v_off_ini = 424.607 uV, v_off_fin = 425.705 uV 16:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.946 uVs 16:01:55 Integrated Voltage Measurement... 16:02:04 Voltage Offset Correction: v_off_ini = 415.576 uV, v_off_fin = 404.974 uV 16:02:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.965 uVs 16:02:04 Integrated Voltage Measurement... 16:02:13 Voltage Offset Correction: v_off_ini = 416.929 uV, v_off_fin = 431.314 uV 16:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.127 uVs 16:02:16 I2X Average and RMS of Measurements VT = -85.481 +- 3.707 uVs I2X = 7.864 +- 0.341 uTm^2 16:02:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:02:24 Integrated Voltage Measurement... 16:02:33 Voltage Offset Correction: v_off_ini = 424.088 uV, v_off_fin = 421.256 uV 16:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.220 uVs 16:02:33 Integrated Voltage Measurement... 16:02:42 Voltage Offset Correction: v_off_ini = 422.486 uV, v_off_fin = 423.943 uV 16:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.541 uVs 16:02:42 Integrated Voltage Measurement... 16:02:51 Voltage Offset Correction: v_off_ini = 423.687 uV, v_off_fin = 414.956 uV 16:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.223 uVs 16:02:51 Integrated Voltage Measurement... 16:03:00 Voltage Offset Correction: v_off_ini = 417.530 uV, v_off_fin = 410.690 uV 16:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.064 uVs 16:03:00 Integrated Voltage Measurement... 16:03:09 Voltage Offset Correction: v_off_ini = 426.986 uV, v_off_fin = 413.630 uV 16:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.964 uVs 16:03:09 Integrated Voltage Measurement... 16:03:18 Voltage Offset Correction: v_off_ini = 409.822 uV, v_off_fin = 417.307 uV 16:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.549 uVs 16:03:20 I2Y Average and RMS of Measurements VT = -207.594 +- 6.726 uVs I2Y = -19.099 +- 0.619 uTm^2 16:03:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:03:32 Integrated Voltage Measurement... 16:03:41 Voltage Offset Correction: v_off_ini = 410.236 uV, v_off_fin = 407.783 uV 16:03:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.979 uVs 16:03:41 Integrated Voltage Measurement... 16:03:50 Voltage Offset Correction: v_off_ini = 407.984 uV, v_off_fin = 413.906 uV 16:03:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.924 uVs 16:03:50 Integrated Voltage Measurement... 16:03:59 Voltage Offset Correction: v_off_ini = 401.192 uV, v_off_fin = 412.584 uV 16:03:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.672 uVs 16:03:59 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = 407.092 uV, v_off_fin = 407.396 uV 16:04:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.213 uVs 16:04:08 Integrated Voltage Measurement... 16:04:17 Voltage Offset Correction: v_off_ini = 402.521 uV, v_off_fin = 410.851 uV 16:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.786 uVs 16:04:17 Integrated Voltage Measurement... 16:04:26 Voltage Offset Correction: v_off_ini = 397.378 uV, v_off_fin = 394.125 uV 16:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.715 uVs 16:04:30 I1X Average and RMS of Measurements VT = -54.381 +- 7.542 uVs I1X = 10.876 +- 1.508 uTm 16:04:33 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:04:37 Integrated Voltage Measurement... 16:04:46 Voltage Offset Correction: v_off_ini = 399.191 uV, v_off_fin = 398.318 uV 16:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.414 uVs 16:04:46 Integrated Voltage Measurement... 16:04:55 Voltage Offset Correction: v_off_ini = 389.147 uV, v_off_fin = 409.268 uV 16:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.205 uVs 16:04:55 Integrated Voltage Measurement... 16:05:04 Voltage Offset Correction: v_off_ini = 399.629 uV, v_off_fin = 390.328 uV 16:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.700 uVs 16:05:04 Integrated Voltage Measurement... 16:05:13 Voltage Offset Correction: v_off_ini = 402.689 uV, v_off_fin = 412.832 uV 16:05:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.463 uVs 16:05:13 Integrated Voltage Measurement... 16:05:22 Voltage Offset Correction: v_off_ini = 390.815 uV, v_off_fin = 382.696 uV 16:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.835 uVs 16:05:22 Integrated Voltage Measurement... 16:05:31 Voltage Offset Correction: v_off_ini = 390.035 uV, v_off_fin = 407.102 uV 16:05:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.923 uVs 16:05:35 I1Y Average and RMS of Measurements VT = -205.256 +- 2.424 uVs I1Y = -41.051 +- 0.485 uTm 16:05:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = 390.415 uV, v_off_fin = 383.391 uV 16:05:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -22.668 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 384.615 uV, v_off_fin = 398.602 uV 16:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.187 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = 393.104 uV, v_off_fin = 392.737 uV 16:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.916 uVs 16:06:08 Integrated Voltage Measurement... 16:06:17 Voltage Offset Correction: v_off_ini = 396.739 uV, v_off_fin = 398.989 uV 16:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.069 uVs 16:06:17 Integrated Voltage Measurement... 16:06:26 Voltage Offset Correction: v_off_ini = 399.983 uV, v_off_fin = 389.882 uV 16:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.345 uVs 16:06:26 Integrated Voltage Measurement... 16:06:35 Voltage Offset Correction: v_off_ini = 401.395 uV, v_off_fin = 398.058 uV 16:06:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.321 uVs 16:06:37 I2X Average and RMS of Measurements VT = -31.584 +- 3.617 uVs I2X = 2.906 +- 0.333 uTm^2 16:06:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:06:42 Integrated Voltage Measurement... 16:06:51 Voltage Offset Correction: v_off_ini = 411.841 uV, v_off_fin = 411.033 uV 16:06:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.685 uVs 16:06:51 Integrated Voltage Measurement... 16:07:00 Voltage Offset Correction: v_off_ini = 407.198 uV, v_off_fin = 398.706 uV 16:07:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.296 uVs 16:07:00 Integrated Voltage Measurement... 16:07:09 Voltage Offset Correction: v_off_ini = 404.115 uV, v_off_fin = 398.484 uV 16:07:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.626 uVs 16:07:09 Integrated Voltage Measurement... 16:07:18 Voltage Offset Correction: v_off_ini = 398.946 uV, v_off_fin = 389.734 uV 16:07:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.496 uVs 16:07:18 Integrated Voltage Measurement... 16:07:27 Voltage Offset Correction: v_off_ini = 398.866 uV, v_off_fin = 392.100 uV 16:07:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.361 uVs 16:07:27 Integrated Voltage Measurement... 16:07:36 Voltage Offset Correction: v_off_ini = 390.307 uV, v_off_fin = 396.549 uV 16:07:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.821 uVs 16:07:39 I2Y Average and RMS of Measurements VT = -198.881 +- 6.880 uVs I2Y = -18.297 +- 0.633 uTm^2 16:07:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:07:47 Integrated Voltage Measurement... 16:07:56 Voltage Offset Correction: v_off_ini = 394.058 uV, v_off_fin = 399.105 uV 16:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.263 uVs 16:07:56 Integrated Voltage Measurement... 16:08:05 Voltage Offset Correction: v_off_ini = 390.636 uV, v_off_fin = 392.179 uV 16:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.582 uVs 16:08:05 Integrated Voltage Measurement... 16:08:14 Voltage Offset Correction: v_off_ini = 404.536 uV, v_off_fin = 402.252 uV 16:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.979 uVs 16:08:14 Integrated Voltage Measurement... 16:08:23 Voltage Offset Correction: v_off_ini = 409.047 uV, v_off_fin = 405.774 uV 16:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.102 uVs 16:08:23 Integrated Voltage Measurement... 16:08:32 Voltage Offset Correction: v_off_ini = 396.827 uV, v_off_fin = 389.735 uV 16:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.059 uVs 16:08:32 Integrated Voltage Measurement... 16:08:41 Voltage Offset Correction: v_off_ini = 386.025 uV, v_off_fin = 403.439 uV 16:08:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.086 uVs 16:08:45 I1X Average and RMS of Measurements VT = -59.512 +- 5.678 uVs I1X = 11.903 +- 1.135 uTm 16:08:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:08:52 Integrated Voltage Measurement... 16:09:01 Voltage Offset Correction: v_off_ini = 389.193 uV, v_off_fin = 395.466 uV 16:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.038 uVs 16:09:01 Integrated Voltage Measurement... 16:09:10 Voltage Offset Correction: v_off_ini = 412.248 uV, v_off_fin = 406.553 uV 16:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.414 uVs 16:09:10 Integrated Voltage Measurement... 16:09:19 Voltage Offset Correction: v_off_ini = 388.172 uV, v_off_fin = 386.013 uV 16:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.694 uVs 16:09:19 Integrated Voltage Measurement... 16:09:28 Voltage Offset Correction: v_off_ini = 388.276 uV, v_off_fin = 398.718 uV 16:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.387 uVs 16:09:28 Integrated Voltage Measurement... 16:09:37 Voltage Offset Correction: v_off_ini = 392.555 uV, v_off_fin = 377.520 uV 16:09:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.609 uVs 16:09:37 Integrated Voltage Measurement... 16:09:46 Voltage Offset Correction: v_off_ini = 397.211 uV, v_off_fin = 397.036 uV 16:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.437 uVs 16:09:50 I1Y Average and RMS of Measurements VT = -214.930 +- 7.169 uVs I1Y = -42.986 +- 1.434 uTm 16:09:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:09:56 Integrated Voltage Measurement... 16:10:04 Voltage Offset Correction: v_off_ini = 395.366 uV, v_off_fin = 400.924 uV 16:10:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.491 uVs 16:10:05 Integrated Voltage Measurement... 16:10:14 Voltage Offset Correction: v_off_ini = 399.689 uV, v_off_fin = 410.397 uV 16:10:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.100 uVs 16:10:14 Integrated Voltage Measurement... 16:10:23 Voltage Offset Correction: v_off_ini = 396.479 uV, v_off_fin = 395.451 uV 16:10:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.767 uVs 16:10:23 Integrated Voltage Measurement... 16:10:32 Voltage Offset Correction: v_off_ini = 403.303 uV, v_off_fin = 402.718 uV 16:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.913 uVs 16:10:32 Integrated Voltage Measurement... 16:10:41 Voltage Offset Correction: v_off_ini = 380.587 uV, v_off_fin = 383.549 uV 16:10:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.257 uVs 16:10:41 Integrated Voltage Measurement... 16:10:50 Voltage Offset Correction: v_off_ini = 385.410 uV, v_off_fin = 394.180 uV 16:10:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.082 uVs 16:10:52 I2X Average and RMS of Measurements VT = -38.435 +- 7.202 uVs I2X = 3.536 +- 0.663 uTm^2 16:10:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:10:57 Integrated Voltage Measurement... 16:11:06 Voltage Offset Correction: v_off_ini = 391.563 uV, v_off_fin = 389.444 uV 16:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.243 uVs 16:11:06 Integrated Voltage Measurement... 16:11:15 Voltage Offset Correction: v_off_ini = 391.828 uV, v_off_fin = 385.412 uV 16:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.131 uVs 16:11:15 Integrated Voltage Measurement... 16:11:24 Voltage Offset Correction: v_off_ini = 383.413 uV, v_off_fin = 387.643 uV 16:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.489 uVs 16:11:24 Integrated Voltage Measurement... 16:11:33 Voltage Offset Correction: v_off_ini = 396.191 uV, v_off_fin = 393.779 uV 16:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.436 uVs 16:11:33 Integrated Voltage Measurement... 16:11:42 Voltage Offset Correction: v_off_ini = 381.165 uV, v_off_fin = 380.577 uV 16:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.616 uVs 16:11:42 Integrated Voltage Measurement... 16:11:51 Voltage Offset Correction: v_off_ini = 387.582 uV, v_off_fin = 378.121 uV 16:11:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 202.245 uVs 16:11:54 I2Y Average and RMS of Measurements VT = -203.693 +- 6.871 uVs I2Y = -18.740 +- 0.633 uTm^2 16:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:02 Integrated Voltage Measurement... 16:12:11 Voltage Offset Correction: v_off_ini = 375.568 uV, v_off_fin = 380.782 uV 16:12:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -71.397 uVs 16:12:11 Integrated Voltage Measurement... 16:12:20 Voltage Offset Correction: v_off_ini = 382.860 uV, v_off_fin = 382.243 uV 16:12:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.775 uVs 16:12:20 Integrated Voltage Measurement... 16:12:29 Voltage Offset Correction: v_off_ini = 380.454 uV, v_off_fin = 374.583 uV 16:12:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.152 uVs 16:12:29 Integrated Voltage Measurement... 16:12:38 Voltage Offset Correction: v_off_ini = 365.170 uV, v_off_fin = 366.842 uV 16:12:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.411 uVs 16:12:38 Integrated Voltage Measurement... 16:12:47 Voltage Offset Correction: v_off_ini = 356.908 uV, v_off_fin = 356.345 uV 16:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.511 uVs 16:12:47 Integrated Voltage Measurement... 16:12:56 Voltage Offset Correction: v_off_ini = 362.458 uV, v_off_fin = 367.947 uV 16:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.575 uVs 16:13:00 I1X Average and RMS of Measurements VT = -72.970 +- 8.433 uVs I1X = 14.594 +- 1.686 uTm 16:13:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:07 Integrated Voltage Measurement... 16:13:16 Voltage Offset Correction: v_off_ini = 359.494 uV, v_off_fin = 356.334 uV 16:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.738 uVs 16:13:16 Integrated Voltage Measurement... 16:13:25 Voltage Offset Correction: v_off_ini = 365.574 uV, v_off_fin = 359.067 uV 16:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.845 uVs 16:13:25 Integrated Voltage Measurement... 16:13:34 Voltage Offset Correction: v_off_ini = 354.692 uV, v_off_fin = 342.050 uV 16:13:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.021 uVs 16:13:34 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = 352.217 uV, v_off_fin = 378.224 uV 16:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.617 uVs 16:13:43 Integrated Voltage Measurement... 16:13:52 Voltage Offset Correction: v_off_ini = 367.132 uV, v_off_fin = 353.453 uV 16:13:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.497 uVs 16:13:52 Integrated Voltage Measurement... 16:14:01 Voltage Offset Correction: v_off_ini = 359.064 uV, v_off_fin = 368.626 uV 16:14:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.177 uVs 16:14:05 I1Y Average and RMS of Measurements VT = -225.316 +- 1.081 uVs I1Y = -45.064 +- 0.217 uTm 16:14:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:11 Integrated Voltage Measurement... 16:14:20 Voltage Offset Correction: v_off_ini = 349.238 uV, v_off_fin = 357.217 uV 16:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.216 uVs 16:14:20 Integrated Voltage Measurement... 16:14:29 Voltage Offset Correction: v_off_ini = 376.323 uV, v_off_fin = 373.991 uV 16:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.657 uVs 16:14:29 Integrated Voltage Measurement... 16:14:38 Voltage Offset Correction: v_off_ini = 371.244 uV, v_off_fin = 361.531 uV 16:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.447 uVs 16:14:38 Integrated Voltage Measurement... 16:14:47 Voltage Offset Correction: v_off_ini = 361.609 uV, v_off_fin = 371.399 uV 16:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.401 uVs 16:14:47 Integrated Voltage Measurement... 16:14:56 Voltage Offset Correction: v_off_ini = 370.239 uV, v_off_fin = 358.193 uV 16:14:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.074 uVs 16:14:56 Integrated Voltage Measurement... 16:15:05 Voltage Offset Correction: v_off_ini = 382.652 uV, v_off_fin = 386.374 uV 16:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.089 uVs 16:15:07 I2X Average and RMS of Measurements VT = -46.647 +- 9.620 uVs I2X = 4.292 +- 0.885 uTm^2 16:15:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:12 Integrated Voltage Measurement... 16:15:21 Voltage Offset Correction: v_off_ini = 371.702 uV, v_off_fin = 376.429 uV 16:15:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.473 uVs 16:15:21 Integrated Voltage Measurement... 16:15:30 Voltage Offset Correction: v_off_ini = 363.783 uV, v_off_fin = 368.318 uV 16:15:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.240 uVs 16:15:30 Integrated Voltage Measurement... 16:15:39 Voltage Offset Correction: v_off_ini = 371.824 uV, v_off_fin = 371.843 uV 16:15:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.220 uVs 16:15:39 Integrated Voltage Measurement... 16:15:48 Voltage Offset Correction: v_off_ini = 358.656 uV, v_off_fin = 373.144 uV 16:15:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.668 uVs 16:15:48 Integrated Voltage Measurement... 16:15:57 Voltage Offset Correction: v_off_ini = 370.477 uV, v_off_fin = 375.153 uV 16:15:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.327 uVs 16:15:57 Integrated Voltage Measurement... 16:16:06 Voltage Offset Correction: v_off_ini = 375.431 uV, v_off_fin = 378.532 uV 16:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.214 uVs 16:16:09 I2Y Average and RMS of Measurements VT = -218.857 +- 2.767 uVs I2Y = -20.135 +- 0.255 uTm^2 16:16:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:16:17 Integrated Voltage Measurement... 16:16:26 Voltage Offset Correction: v_off_ini = 388.236 uV, v_off_fin = 384.817 uV 16:16:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.474 uVs 16:16:26 Integrated Voltage Measurement... 16:16:35 Voltage Offset Correction: v_off_ini = 383.371 uV, v_off_fin = 380.035 uV 16:16:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.777 uVs 16:16:35 Integrated Voltage Measurement... 16:16:44 Voltage Offset Correction: v_off_ini = 394.857 uV, v_off_fin = 377.036 uV 16:16:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.573 uVs 16:16:44 Integrated Voltage Measurement... 16:16:53 Voltage Offset Correction: v_off_ini = 391.287 uV, v_off_fin = 391.436 uV 16:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.258 uVs 16:16:53 Integrated Voltage Measurement... 16:17:02 Voltage Offset Correction: v_off_ini = 387.091 uV, v_off_fin = 394.757 uV 16:17:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.566 uVs 16:17:02 Integrated Voltage Measurement... 16:17:11 Voltage Offset Correction: v_off_ini = 393.319 uV, v_off_fin = 387.686 uV 16:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.684 uVs 16:17:16 I1X Average and RMS of Measurements VT = -66.389 +- 7.057 uVs I1X = 13.278 +- 1.412 uTm 16:17:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:17:22 Integrated Voltage Measurement... 16:17:31 Voltage Offset Correction: v_off_ini = 388.212 uV, v_off_fin = 385.014 uV 16:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.295 uVs 16:17:31 Integrated Voltage Measurement... 16:17:40 Voltage Offset Correction: v_off_ini = 391.589 uV, v_off_fin = 406.929 uV 16:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.652 uVs 16:17:40 Integrated Voltage Measurement... 16:17:49 Voltage Offset Correction: v_off_ini = 386.731 uV, v_off_fin = 379.180 uV 16:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.423 uVs 16:17:49 Integrated Voltage Measurement... 16:17:58 Voltage Offset Correction: v_off_ini = 392.892 uV, v_off_fin = 399.381 uV 16:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.687 uVs 16:17:58 Integrated Voltage Measurement... 16:18:07 Voltage Offset Correction: v_off_ini = 392.886 uV, v_off_fin = 379.542 uV 16:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.785 uVs 16:18:07 Integrated Voltage Measurement... 16:18:16 Voltage Offset Correction: v_off_ini = 392.038 uV, v_off_fin = 404.637 uV 16:18:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.185 uVs 16:18:20 I1Y Average and RMS of Measurements VT = -226.005 +- 1.097 uVs I1Y = -45.202 +- 0.218 uTm 16:18:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:18:26 Integrated Voltage Measurement... 16:18:35 Voltage Offset Correction: v_off_ini = 381.870 uV, v_off_fin = 378.900 uV 16:18:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.739 uVs 16:18:35 Integrated Voltage Measurement... 16:18:44 Voltage Offset Correction: v_off_ini = 388.962 uV, v_off_fin = 391.751 uV 16:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.834 uVs 16:18:44 Integrated Voltage Measurement... 16:18:53 Voltage Offset Correction: v_off_ini = 381.804 uV, v_off_fin = 370.155 uV 16:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.502 uVs 16:18:53 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = 373.310 uV, v_off_fin = 373.501 uV 16:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.767 uVs 16:19:02 Integrated Voltage Measurement... 16:19:11 Voltage Offset Correction: v_off_ini = 383.500 uV, v_off_fin = 363.458 uV 16:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.358 uVs 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = 371.942 uV, v_off_fin = 382.655 uV 16:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.085 uVs 16:19:22 I2X Average and RMS of Measurements VT = -57.881 +- 10.053 uVs I2X = 5.325 +- 0.925 uTm^2 16:19:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:19:27 Integrated Voltage Measurement... 16:19:36 Voltage Offset Correction: v_off_ini = 382.523 uV, v_off_fin = 370.062 uV 16:19:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.633 uVs 16:19:36 Integrated Voltage Measurement... 16:19:45 Voltage Offset Correction: v_off_ini = 387.464 uV, v_off_fin = 390.418 uV 16:19:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.481 uVs 16:19:45 Integrated Voltage Measurement... 16:19:54 Voltage Offset Correction: v_off_ini = 378.772 uV, v_off_fin = 368.582 uV 16:19:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.946 uVs 16:19:54 Integrated Voltage Measurement... 16:20:03 Voltage Offset Correction: v_off_ini = 365.357 uV, v_off_fin = 375.793 uV 16:20:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.396 uVs 16:20:03 Integrated Voltage Measurement... 16:20:12 Voltage Offset Correction: v_off_ini = 369.592 uV, v_off_fin = 364.414 uV 16:20:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.818 uVs 16:20:13 Integrated Voltage Measurement... 16:20:21 Voltage Offset Correction: v_off_ini = 360.862 uV, v_off_fin = 371.646 uV 16:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.008 uVs 16:20:24 I2Y Average and RMS of Measurements VT = -227.047 +- 1.589 uVs I2Y = -20.888 +- 0.146 uTm^2 16:20:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:20:32 Integrated Voltage Measurement... 16:20:41 Voltage Offset Correction: v_off_ini = 377.001 uV, v_off_fin = 367.479 uV 16:20:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.455 uVs 16:20:41 Integrated Voltage Measurement... 16:20:50 Voltage Offset Correction: v_off_ini = 369.153 uV, v_off_fin = 375.865 uV 16:20:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.733 uVs 16:20:50 Integrated Voltage Measurement... 16:20:59 Voltage Offset Correction: v_off_ini = 361.037 uV, v_off_fin = 361.688 uV 16:20:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.599 uVs 16:20:59 Integrated Voltage Measurement... 16:21:08 Voltage Offset Correction: v_off_ini = 355.713 uV, v_off_fin = 363.454 uV 16:21:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.968 uVs 16:21:08 Integrated Voltage Measurement... 16:21:17 Voltage Offset Correction: v_off_ini = 357.509 uV, v_off_fin = 360.172 uV 16:21:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.857 uVs 16:21:17 Integrated Voltage Measurement... 16:21:26 Voltage Offset Correction: v_off_ini = 361.856 uV, v_off_fin = 367.435 uV 16:21:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.189 uVs 16:21:31 I1X Average and RMS of Measurements VT = -63.467 +- 3.691 uVs I1X = 12.694 +- 0.738 uTm 16:21:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:21:37 Integrated Voltage Measurement... 16:21:46 Voltage Offset Correction: v_off_ini = 367.307 uV, v_off_fin = 357.434 uV 16:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -231.433 uVs 16:21:46 Integrated Voltage Measurement... 16:21:55 Voltage Offset Correction: v_off_ini = 365.303 uV, v_off_fin = 373.563 uV 16:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.114 uVs 16:21:55 Integrated Voltage Measurement... 16:22:04 Voltage Offset Correction: v_off_ini = 356.655 uV, v_off_fin = 357.820 uV 16:22:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.132 uVs 16:22:04 Integrated Voltage Measurement... 16:22:13 Voltage Offset Correction: v_off_ini = 367.200 uV, v_off_fin = 378.471 uV 16:22:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.316 uVs 16:22:13 Integrated Voltage Measurement... 16:22:22 Voltage Offset Correction: v_off_ini = 364.420 uV, v_off_fin = 344.630 uV 16:22:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.424 uVs 16:22:22 Integrated Voltage Measurement... 16:22:31 Voltage Offset Correction: v_off_ini = 368.313 uV, v_off_fin = 382.111 uV 16:22:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.801 uVs 16:22:36 I1Y Average and RMS of Measurements VT = -228.870 +- 2.397 uVs I1Y = -45.776 +- 0.479 uTm 16:22:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:22:41 Integrated Voltage Measurement... 16:22:50 Voltage Offset Correction: v_off_ini = 364.143 uV, v_off_fin = 367.328 uV 16:22:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.061 uVs 16:22:50 Integrated Voltage Measurement... 16:22:59 Voltage Offset Correction: v_off_ini = 374.760 uV, v_off_fin = 374.928 uV 16:22:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.766 uVs 16:22:59 Integrated Voltage Measurement... 16:23:08 Voltage Offset Correction: v_off_ini = 370.333 uV, v_off_fin = 361.591 uV 16:23:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.866 uVs 16:23:08 Integrated Voltage Measurement... 16:23:17 Voltage Offset Correction: v_off_ini = 370.863 uV, v_off_fin = 375.497 uV 16:23:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.622 uVs 16:23:17 Integrated Voltage Measurement... 16:23:26 Voltage Offset Correction: v_off_ini = 376.733 uV, v_off_fin = 372.611 uV 16:23:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.653 uVs 16:23:26 Integrated Voltage Measurement... 16:23:35 Voltage Offset Correction: v_off_ini = 359.180 uV, v_off_fin = 366.675 uV 16:23:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.885 uVs 16:23:37 I2X Average and RMS of Measurements VT = -57.142 +- 5.104 uVs I2X = 5.257 +- 0.470 uTm^2 16:23:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:23:42 Integrated Voltage Measurement... 16:23:51 Voltage Offset Correction: v_off_ini = 376.281 uV, v_off_fin = 374.431 uV 16:23:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.746 uVs 16:23:51 Integrated Voltage Measurement... 16:24:00 Voltage Offset Correction: v_off_ini = 366.037 uV, v_off_fin = 370.592 uV 16:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.876 uVs 16:24:00 Integrated Voltage Measurement... 16:24:09 Voltage Offset Correction: v_off_ini = 373.699 uV, v_off_fin = 366.618 uV 16:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.717 uVs 16:24:09 Integrated Voltage Measurement... 16:24:18 Voltage Offset Correction: v_off_ini = 373.243 uV, v_off_fin = 374.551 uV 16:24:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.952 uVs 16:24:19 Integrated Voltage Measurement... 16:24:28 Voltage Offset Correction: v_off_ini = 371.034 uV, v_off_fin = 375.513 uV 16:24:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.643 uVs 16:24:28 Integrated Voltage Measurement... 16:24:37 Voltage Offset Correction: v_off_ini = 381.893 uV, v_off_fin = 367.175 uV 16:24:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.800 uVs 16:24:39 I2Y Average and RMS of Measurements VT = -236.789 +- 4.129 uVs I2Y = -21.785 +- 0.380 uTm^2 16:24:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:25:00 Integrated Voltage Measurement... 16:25:09 Voltage Offset Correction: v_off_ini = 414.292 uV, v_off_fin = 409.313 uV 16:25:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -63.939 uVs 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = 415.502 uV, v_off_fin = 416.389 uV 16:25:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.105 uVs 16:25:18 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = 409.248 uV, v_off_fin = 415.829 uV 16:25:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.357 uVs 16:25:27 Integrated Voltage Measurement... 16:25:36 Voltage Offset Correction: v_off_ini = 411.460 uV, v_off_fin = 415.282 uV 16:25:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.073 uVs 16:25:36 Integrated Voltage Measurement... 16:25:45 Voltage Offset Correction: v_off_ini = 411.488 uV, v_off_fin = 416.839 uV 16:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.541 uVs 16:25:45 Integrated Voltage Measurement... 16:25:54 Voltage Offset Correction: v_off_ini = 415.068 uV, v_off_fin = 413.108 uV 16:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.865 uVs 16:25:59 I1X Average and RMS of Measurements VT = -37.147 +- 9.311 uVs I1X = 7.430 +- 1.863 uTm 16:26:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:26:05 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = 388.240 uV, v_off_fin = 381.137 uV 16:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.061 uVs 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = 394.487 uV, v_off_fin = 406.249 uV 16:26:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.403 uVs 16:26:23 Integrated Voltage Measurement... 16:26:32 Voltage Offset Correction: v_off_ini = 380.361 uV, v_off_fin = 390.988 uV 16:26:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.807 uVs 16:26:32 Integrated Voltage Measurement... 16:26:41 Voltage Offset Correction: v_off_ini = 391.086 uV, v_off_fin = 408.564 uV 16:26:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.840 uVs 16:26:41 Integrated Voltage Measurement... 16:26:50 Voltage Offset Correction: v_off_ini = 398.055 uV, v_off_fin = 382.070 uV 16:26:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.838 uVs 16:26:50 Integrated Voltage Measurement... 16:26:59 Voltage Offset Correction: v_off_ini = 400.911 uV, v_off_fin = 404.134 uV 16:26:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.161 uVs 16:27:03 I1Y Average and RMS of Measurements VT = -230.018 +- 1.986 uVs I1Y = -46.004 +- 0.397 uTm 16:27:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:27:11 Integrated Voltage Measurement... 16:27:20 Voltage Offset Correction: v_off_ini = 378.444 uV, v_off_fin = 367.268 uV 16:27:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -24.055 uVs 16:27:20 Integrated Voltage Measurement... 16:27:29 Voltage Offset Correction: v_off_ini = 382.227 uV, v_off_fin = 388.419 uV 16:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.137 uVs 16:27:29 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 392.673 uV, v_off_fin = 373.060 uV 16:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.175 uVs 16:27:38 Integrated Voltage Measurement... 16:27:47 Voltage Offset Correction: v_off_ini = 371.163 uV, v_off_fin = 381.654 uV 16:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.591 uVs 16:27:47 Integrated Voltage Measurement... 16:27:56 Voltage Offset Correction: v_off_ini = 379.502 uV, v_off_fin = 384.626 uV 16:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.460 uVs 16:27:56 Integrated Voltage Measurement... 16:28:05 Voltage Offset Correction: v_off_ini = 391.060 uV, v_off_fin = 383.320 uV 16:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.878 uVs 16:28:08 I2X Average and RMS of Measurements VT = -38.716 +- 7.515 uVs I2X = 3.562 +- 0.691 uTm^2 16:28:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:28:15 Integrated Voltage Measurement... 16:28:24 Voltage Offset Correction: v_off_ini = 378.900 uV, v_off_fin = 385.583 uV 16:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.501 uVs 16:28:25 Integrated Voltage Measurement... 16:28:33 Voltage Offset Correction: v_off_ini = 385.547 uV, v_off_fin = 382.165 uV 16:28:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.281 uVs 16:28:34 Integrated Voltage Measurement... 16:28:43 Voltage Offset Correction: v_off_ini = 393.826 uV, v_off_fin = 370.104 uV 16:28:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.823 uVs 16:28:43 Integrated Voltage Measurement... 16:28:52 Voltage Offset Correction: v_off_ini = 379.882 uV, v_off_fin = 386.465 uV 16:28:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.414 uVs 16:28:52 Integrated Voltage Measurement... 16:29:01 Voltage Offset Correction: v_off_ini = 406.160 uV, v_off_fin = 395.637 uV 16:29:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.466 uVs 16:29:01 Integrated Voltage Measurement... 16:29:10 Voltage Offset Correction: v_off_ini = 393.279 uV, v_off_fin = 387.444 uV 16:29:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.950 uVs 16:29:12 I2Y Average and RMS of Measurements VT = -228.406 +- 4.097 uVs I2Y = -21.013 +- 0.377 uTm^2 16:29:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:29:21 Integrated Voltage Measurement... 16:29:30 Voltage Offset Correction: v_off_ini = 387.158 uV, v_off_fin = 379.302 uV 16:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.776 uVs 16:29:30 Integrated Voltage Measurement... 16:29:39 Voltage Offset Correction: v_off_ini = 393.784 uV, v_off_fin = 395.523 uV 16:29:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.371 uVs 16:29:39 Integrated Voltage Measurement... 16:29:48 Voltage Offset Correction: v_off_ini = 389.795 uV, v_off_fin = 392.085 uV 16:29:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.507 uVs 16:29:48 Integrated Voltage Measurement... 16:29:57 Voltage Offset Correction: v_off_ini = 393.482 uV, v_off_fin = 398.741 uV 16:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.269 uVs 16:29:57 Integrated Voltage Measurement... 16:30:06 Voltage Offset Correction: v_off_ini = 386.342 uV, v_off_fin = 384.991 uV 16:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.796 uVs 16:30:06 Integrated Voltage Measurement... 16:30:15 Voltage Offset Correction: v_off_ini = 385.952 uV, v_off_fin = 400.854 uV 16:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.818 uVs 16:30:19 I1X Average and RMS of Measurements VT = -50.756 +- 9.161 uVs I1X = 10.151 +- 1.832 uTm 16:30:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 384.875 uV, v_off_fin = 377.578 uV 16:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.885 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 395.663 uV, v_off_fin = 399.441 uV 16:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.335 uVs 16:30:44 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = 392.542 uV, v_off_fin = 385.496 uV 16:30:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.280 uVs 16:30:53 Integrated Voltage Measurement... 16:31:02 Voltage Offset Correction: v_off_ini = 391.573 uV, v_off_fin = 408.983 uV 16:31:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.472 uVs 16:31:02 Integrated Voltage Measurement... 16:31:11 Voltage Offset Correction: v_off_ini = 406.348 uV, v_off_fin = 384.749 uV 16:31:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.081 uVs 16:31:11 Integrated Voltage Measurement... 16:31:20 Voltage Offset Correction: v_off_ini = 403.359 uV, v_off_fin = 406.910 uV 16:31:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.774 uVs 16:31:24 I1Y Average and RMS of Measurements VT = -218.638 +- 7.177 uVs I1Y = -43.728 +- 1.435 uTm 16:31:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:31:32 Integrated Voltage Measurement... 16:31:41 Voltage Offset Correction: v_off_ini = 393.209 uV, v_off_fin = 395.803 uV 16:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.185 uVs 16:31:41 Integrated Voltage Measurement... 16:31:50 Voltage Offset Correction: v_off_ini = 390.018 uV, v_off_fin = 407.221 uV 16:31:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.100 uVs 16:31:50 Integrated Voltage Measurement... 16:31:59 Voltage Offset Correction: v_off_ini = 403.912 uV, v_off_fin = 375.235 uV 16:31:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.256 uVs 16:31:59 Integrated Voltage Measurement... 16:32:08 Voltage Offset Correction: v_off_ini = 374.449 uV, v_off_fin = 384.380 uV 16:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.942 uVs 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 382.102 uV, v_off_fin = 382.036 uV 16:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.742 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 387.397 uV, v_off_fin = 383.756 uV 16:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.617 uVs 16:32:29 I2X Average and RMS of Measurements VT = -42.974 +- 3.729 uVs I2X = 3.954 +- 0.343 uTm^2 16:32:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:32:36 Integrated Voltage Measurement... 16:32:45 Voltage Offset Correction: v_off_ini = 375.938 uV, v_off_fin = 363.413 uV 16:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.594 uVs 16:32:45 Integrated Voltage Measurement... 16:32:54 Voltage Offset Correction: v_off_ini = 369.829 uV, v_off_fin = 374.464 uV 16:32:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.059 uVs 16:32:54 Integrated Voltage Measurement... 16:33:03 Voltage Offset Correction: v_off_ini = 364.746 uV, v_off_fin = 370.082 uV 16:33:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.081 uVs 16:33:03 Integrated Voltage Measurement... 16:33:12 Voltage Offset Correction: v_off_ini = 374.997 uV, v_off_fin = 384.522 uV 16:33:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.841 uVs 16:33:12 Integrated Voltage Measurement... 16:33:21 Voltage Offset Correction: v_off_ini = 375.548 uV, v_off_fin = 372.606 uV 16:33:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.583 uVs 16:33:21 Integrated Voltage Measurement... 16:33:30 Voltage Offset Correction: v_off_ini = 367.764 uV, v_off_fin = 364.449 uV 16:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.498 uVs 16:33:33 I2Y Average and RMS of Measurements VT = -220.276 +- 0.693 uVs I2Y = -20.265 +- 0.064 uTm^2 16:33:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:42 Integrated Voltage Measurement... 16:33:51 Voltage Offset Correction: v_off_ini = 369.089 uV, v_off_fin = 360.775 uV 16:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.214 uVs 16:33:51 Integrated Voltage Measurement... 16:34:00 Voltage Offset Correction: v_off_ini = 371.180 uV, v_off_fin = 371.138 uV 16:34:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.163 uVs 16:34:00 Integrated Voltage Measurement... 16:34:09 Voltage Offset Correction: v_off_ini = 377.324 uV, v_off_fin = 391.670 uV 16:34:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.162 uVs 16:34:09 Integrated Voltage Measurement... 16:34:18 Voltage Offset Correction: v_off_ini = 392.288 uV, v_off_fin = 394.248 uV 16:34:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.443 uVs 16:34:18 Integrated Voltage Measurement... 16:34:27 Voltage Offset Correction: v_off_ini = 392.856 uV, v_off_fin = 385.564 uV 16:34:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.416 uVs 16:34:27 Integrated Voltage Measurement... 16:34:36 Voltage Offset Correction: v_off_ini = 392.518 uV, v_off_fin = 398.028 uV 16:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.223 uVs 16:34:40 I1X Average and RMS of Measurements VT = -65.103 +- 6.886 uVs I1X = 13.021 +- 1.378 uTm 16:34:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:47 Integrated Voltage Measurement... 16:34:56 Voltage Offset Correction: v_off_ini = 395.387 uV, v_off_fin = 375.466 uV 16:34:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.500 uVs 16:34:56 Integrated Voltage Measurement... 16:35:05 Voltage Offset Correction: v_off_ini = 367.618 uV, v_off_fin = 391.325 uV 16:35:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.018 uVs 16:35:05 Integrated Voltage Measurement... 16:35:14 Voltage Offset Correction: v_off_ini = 390.760 uV, v_off_fin = 376.048 uV 16:35:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.876 uVs 16:35:14 Integrated Voltage Measurement... 16:35:23 Voltage Offset Correction: v_off_ini = 389.663 uV, v_off_fin = 409.260 uV 16:35:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.187 uVs 16:35:23 Integrated Voltage Measurement... 16:35:32 Voltage Offset Correction: v_off_ini = 399.594 uV, v_off_fin = 380.811 uV 16:35:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.038 uVs 16:35:32 Integrated Voltage Measurement... 16:35:41 Voltage Offset Correction: v_off_ini = 395.908 uV, v_off_fin = 403.986 uV 16:35:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.445 uVs 16:35:45 I1Y Average and RMS of Measurements VT = -216.511 +- 5.834 uVs I1Y = -43.303 +- 1.168 uTm 16:35:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:53 Integrated Voltage Measurement... 16:36:02 Voltage Offset Correction: v_off_ini = 387.719 uV, v_off_fin = 380.963 uV 16:36:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.113 uVs 16:36:02 Integrated Voltage Measurement... 16:36:11 Voltage Offset Correction: v_off_ini = 392.005 uV, v_off_fin = 381.901 uV 16:36:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.955 uVs 16:36:11 Integrated Voltage Measurement... 16:36:20 Voltage Offset Correction: v_off_ini = 392.245 uV, v_off_fin = 387.840 uV 16:36:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.478 uVs 16:36:20 Integrated Voltage Measurement... 16:36:29 Voltage Offset Correction: v_off_ini = 396.528 uV, v_off_fin = 396.522 uV 16:36:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.242 uVs 16:36:29 Integrated Voltage Measurement... 16:36:38 Voltage Offset Correction: v_off_ini = 392.526 uV, v_off_fin = 385.286 uV 16:36:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.620 uVs 16:36:38 Integrated Voltage Measurement... 16:36:47 Voltage Offset Correction: v_off_ini = 399.439 uV, v_off_fin = 401.368 uV 16:36:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.120 uVs 16:36:49 I2X Average and RMS of Measurements VT = -55.754 +- 6.250 uVs I2X = 5.129 +- 0.575 uTm^2 16:36:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:57 Integrated Voltage Measurement... 16:37:06 Voltage Offset Correction: v_off_ini = 397.185 uV, v_off_fin = 378.161 uV 16:37:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.928 uVs 16:37:06 Integrated Voltage Measurement... 16:37:15 Voltage Offset Correction: v_off_ini = 382.394 uV, v_off_fin = 395.182 uV 16:37:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.756 uVs 16:37:15 Integrated Voltage Measurement... 16:37:24 Voltage Offset Correction: v_off_ini = 394.498 uV, v_off_fin = 387.090 uV 16:37:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.351 uVs 16:37:24 Integrated Voltage Measurement... 16:37:33 Voltage Offset Correction: v_off_ini = 391.235 uV, v_off_fin = 386.970 uV 16:37:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.515 uVs 16:37:33 Integrated Voltage Measurement... 16:37:42 Voltage Offset Correction: v_off_ini = 389.710 uV, v_off_fin = 381.118 uV 16:37:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.298 uVs 16:37:42 Integrated Voltage Measurement... 16:37:51 Voltage Offset Correction: v_off_ini = 381.434 uV, v_off_fin = 392.901 uV 16:37:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.579 uVs 16:37:53 I2Y Average and RMS of Measurements VT = -222.238 +- 6.586 uVs I2Y = -20.446 +- 0.606 uTm^2 16:37:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:38:02 Integrated Voltage Measurement... 16:38:11 Voltage Offset Correction: v_off_ini = 403.681 uV, v_off_fin = 381.203 uV 16:38:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.419 uVs 16:38:11 Integrated Voltage Measurement... 16:38:20 Voltage Offset Correction: v_off_ini = 390.135 uV, v_off_fin = 391.653 uV 16:38:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.941 uVs 16:38:20 Integrated Voltage Measurement... 16:38:29 Voltage Offset Correction: v_off_ini = 388.296 uV, v_off_fin = 385.044 uV 16:38:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.579 uVs 16:38:29 Integrated Voltage Measurement... 16:38:38 Voltage Offset Correction: v_off_ini = 387.631 uV, v_off_fin = 394.239 uV 16:38:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 90.045 uVs 16:38:38 Integrated Voltage Measurement... 16:38:47 Voltage Offset Correction: v_off_ini = 392.420 uV, v_off_fin = 399.561 uV 16:38:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.443 uVs 16:38:47 Integrated Voltage Measurement... 16:38:56 Voltage Offset Correction: v_off_ini = 389.531 uV, v_off_fin = 391.617 uV 16:38:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.026 uVs 16:39:00 I1X Average and RMS of Measurements VT = -80.742 +- 2.804 uVs I1X = 16.150 +- 0.560 uTm 16:39:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:39:07 Integrated Voltage Measurement... 16:39:16 Voltage Offset Correction: v_off_ini = 390.369 uV, v_off_fin = 386.882 uV 16:39:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.515 uVs 16:39:16 Integrated Voltage Measurement... 16:39:25 Voltage Offset Correction: v_off_ini = 392.085 uV, v_off_fin = 399.494 uV 16:39:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.582 uVs 16:39:25 Integrated Voltage Measurement... 16:39:34 Voltage Offset Correction: v_off_ini = 394.403 uV, v_off_fin = 377.343 uV 16:39:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.254 uVs 16:39:34 Integrated Voltage Measurement... 16:39:43 Voltage Offset Correction: v_off_ini = 387.988 uV, v_off_fin = 398.761 uV 16:39:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.662 uVs 16:39:43 Integrated Voltage Measurement... 16:39:52 Voltage Offset Correction: v_off_ini = 387.089 uV, v_off_fin = 392.588 uV 16:39:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.757 uVs 16:39:52 Integrated Voltage Measurement... 16:40:01 Voltage Offset Correction: v_off_ini = 392.007 uV, v_off_fin = 401.917 uV 16:40:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.158 uVs 16:40:05 I1Y Average and RMS of Measurements VT = -203.155 +- 3.557 uVs I1Y = -40.632 +- 0.711 uTm 16:40:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:40:13 Integrated Voltage Measurement... 16:40:22 Voltage Offset Correction: v_off_ini = 380.253 uV, v_off_fin = 374.808 uV 16:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.765 uVs 16:40:22 Integrated Voltage Measurement... 16:40:31 Voltage Offset Correction: v_off_ini = 400.167 uV, v_off_fin = 409.939 uV 16:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.951 uVs 16:40:31 Integrated Voltage Measurement... 16:40:40 Voltage Offset Correction: v_off_ini = 390.870 uV, v_off_fin = 403.289 uV 16:40:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.118 uVs 16:40:40 Integrated Voltage Measurement... 16:40:49 Voltage Offset Correction: v_off_ini = 402.771 uV, v_off_fin = 413.811 uV 16:40:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.442 uVs 16:40:49 Integrated Voltage Measurement... 16:40:58 Voltage Offset Correction: v_off_ini = 405.468 uV, v_off_fin = 384.518 uV 16:40:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.558 uVs 16:40:58 Integrated Voltage Measurement... 16:41:07 Voltage Offset Correction: v_off_ini = 392.460 uV, v_off_fin = 402.267 uV 16:41:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.236 uVs 16:41:09 I2X Average and RMS of Measurements VT = -65.345 +- 5.218 uVs I2X = 6.012 +- 0.480 uTm^2 16:41:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:41:17 Integrated Voltage Measurement... 16:41:26 Voltage Offset Correction: v_off_ini = 392.301 uV, v_off_fin = 395.024 uV 16:41:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.877 uVs 16:41:26 Integrated Voltage Measurement... 16:41:35 Voltage Offset Correction: v_off_ini = 389.318 uV, v_off_fin = 403.093 uV 16:41:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.133 uVs 16:41:35 Integrated Voltage Measurement... 16:41:44 Voltage Offset Correction: v_off_ini = 383.212 uV, v_off_fin = 386.394 uV 16:41:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.975 uVs 16:41:44 Integrated Voltage Measurement... 16:41:53 Voltage Offset Correction: v_off_ini = 382.760 uV, v_off_fin = 384.880 uV 16:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.004 uVs 16:41:53 Integrated Voltage Measurement... 16:42:02 Voltage Offset Correction: v_off_ini = 385.310 uV, v_off_fin = 379.266 uV 16:42:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.443 uVs 16:42:02 Integrated Voltage Measurement... 16:42:11 Voltage Offset Correction: v_off_ini = 380.346 uV, v_off_fin = 375.549 uV 16:42:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.809 uVs 16:42:14 I2Y Average and RMS of Measurements VT = -207.707 +- 8.624 uVs I2Y = -19.109 +- 0.793 uTm^2 16:42:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:42:23 Integrated Voltage Measurement... 16:42:32 Voltage Offset Correction: v_off_ini = 386.173 uV, v_off_fin = 366.910 uV 16:42:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.316 uVs 16:42:32 Integrated Voltage Measurement... 16:42:41 Voltage Offset Correction: v_off_ini = 375.598 uV, v_off_fin = 382.454 uV 16:42:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.258 uVs 16:42:41 Integrated Voltage Measurement... 16:42:50 Voltage Offset Correction: v_off_ini = 389.247 uV, v_off_fin = 375.902 uV 16:42:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.160 uVs 16:42:50 Integrated Voltage Measurement... 16:42:59 Voltage Offset Correction: v_off_ini = 383.226 uV, v_off_fin = 378.800 uV 16:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.624 uVs 16:42:59 Integrated Voltage Measurement... 16:43:08 Voltage Offset Correction: v_off_ini = 387.449 uV, v_off_fin = 384.192 uV 16:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.701 uVs 16:43:08 Integrated Voltage Measurement... 16:43:17 Voltage Offset Correction: v_off_ini = 395.446 uV, v_off_fin = 393.600 uV 16:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.926 uVs 16:43:21 I1X Average and RMS of Measurements VT = -102.331 +- 2.572 uVs I1X = 20.467 +- 0.515 uTm 16:43:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:43:28 Integrated Voltage Measurement... 16:43:36 Voltage Offset Correction: v_off_ini = 395.503 uV, v_off_fin = 394.405 uV 16:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.461 uVs 16:43:37 Integrated Voltage Measurement... 16:43:45 Voltage Offset Correction: v_off_ini = 394.103 uV, v_off_fin = 407.603 uV 16:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.502 uVs 16:43:45 Integrated Voltage Measurement... 16:43:54 Voltage Offset Correction: v_off_ini = 402.315 uV, v_off_fin = 395.435 uV 16:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.076 uVs 16:43:54 Integrated Voltage Measurement... 16:44:03 Voltage Offset Correction: v_off_ini = 387.094 uV, v_off_fin = 398.310 uV 16:44:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.644 uVs 16:44:03 Integrated Voltage Measurement... 16:44:12 Voltage Offset Correction: v_off_ini = 394.757 uV, v_off_fin = 394.880 uV 16:44:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.205 uVs 16:44:12 Integrated Voltage Measurement... 16:44:21 Voltage Offset Correction: v_off_ini = 401.826 uV, v_off_fin = 407.625 uV 16:44:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.150 uVs 16:44:26 I1Y Average and RMS of Measurements VT = -194.340 +- 6.763 uVs I1Y = -38.868 +- 1.353 uTm 16:44:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:44:33 Integrated Voltage Measurement... 16:44:42 Voltage Offset Correction: v_off_ini = 399.175 uV, v_off_fin = 384.848 uV 16:44:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.369 uVs 16:44:42 Integrated Voltage Measurement... 16:44:51 Voltage Offset Correction: v_off_ini = 395.063 uV, v_off_fin = 404.011 uV 16:44:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.315 uVs 16:44:51 Integrated Voltage Measurement... 16:45:00 Voltage Offset Correction: v_off_ini = 394.286 uV, v_off_fin = 388.819 uV 16:45:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.883 uVs 16:45:00 Integrated Voltage Measurement... 16:45:09 Voltage Offset Correction: v_off_ini = 395.841 uV, v_off_fin = 395.129 uV 16:45:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.778 uVs 16:45:09 Integrated Voltage Measurement... 16:45:18 Voltage Offset Correction: v_off_ini = 392.518 uV, v_off_fin = 384.935 uV 16:45:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.729 uVs 16:45:18 Integrated Voltage Measurement... 16:45:27 Voltage Offset Correction: v_off_ini = 384.862 uV, v_off_fin = 401.668 uV 16:45:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.361 uVs 16:45:30 I2X Average and RMS of Measurements VT = -80.239 +- 5.805 uVs I2X = 7.382 +- 0.534 uTm^2 16:45:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:45:37 Integrated Voltage Measurement... 16:45:46 Voltage Offset Correction: v_off_ini = 396.233 uV, v_off_fin = 389.460 uV 16:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.017 uVs 16:45:46 Integrated Voltage Measurement... 16:45:55 Voltage Offset Correction: v_off_ini = 392.505 uV, v_off_fin = 391.506 uV 16:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.687 uVs 16:45:55 Integrated Voltage Measurement... 16:46:04 Voltage Offset Correction: v_off_ini = 391.722 uV, v_off_fin = 392.614 uV 16:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.479 uVs 16:46:05 Integrated Voltage Measurement... 16:46:13 Voltage Offset Correction: v_off_ini = 400.434 uV, v_off_fin = 388.894 uV 16:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.564 uVs 16:46:14 Integrated Voltage Measurement... 16:46:22 Voltage Offset Correction: v_off_ini = 387.285 uV, v_off_fin = 384.493 uV 16:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.440 uVs 16:46:23 Integrated Voltage Measurement... 16:46:31 Voltage Offset Correction: v_off_ini = 408.125 uV, v_off_fin = 400.180 uV 16:46:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.719 uVs 16:46:34 I2Y Average and RMS of Measurements VT = -192.484 +- 6.628 uVs I2Y = -17.709 +- 0.610 uTm^2 16:46:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:46:46 Integrated Voltage Measurement... 16:46:55 Voltage Offset Correction: v_off_ini = 381.571 uV, v_off_fin = 379.276 uV 16:46:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -23.363 uVs 16:46:55 Integrated Voltage Measurement... 16:47:04 Voltage Offset Correction: v_off_ini = 390.026 uV, v_off_fin = 392.875 uV 16:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.549 uVs 16:47:04 Integrated Voltage Measurement... 16:47:13 Voltage Offset Correction: v_off_ini = 379.869 uV, v_off_fin = 384.061 uV 16:47:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.258 uVs 16:47:13 Integrated Voltage Measurement... 16:47:22 Voltage Offset Correction: v_off_ini = 385.269 uV, v_off_fin = 381.103 uV 16:47:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.529 uVs 16:47:22 Integrated Voltage Measurement... 16:47:31 Voltage Offset Correction: v_off_ini = 391.152 uV, v_off_fin = 387.628 uV 16:47:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.116 uVs 16:47:31 Integrated Voltage Measurement... 16:47:40 Voltage Offset Correction: v_off_ini = 383.878 uV, v_off_fin = 383.863 uV 16:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.669 uVs 16:47:44 I1X Average and RMS of Measurements VT = -46.747 +- 6.711 uVs I1X = 9.350 +- 1.342 uTm 16:47:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:47:51 Integrated Voltage Measurement... 16:48:00 Voltage Offset Correction: v_off_ini = 413.834 uV, v_off_fin = 388.793 uV 16:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.012 uVs 16:48:00 Integrated Voltage Measurement... 16:48:09 Voltage Offset Correction: v_off_ini = 393.312 uV, v_off_fin = 418.692 uV 16:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.837 uVs 16:48:09 Integrated Voltage Measurement... 16:48:18 Voltage Offset Correction: v_off_ini = 413.965 uV, v_off_fin = 404.541 uV 16:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.668 uVs 16:48:18 Integrated Voltage Measurement... 16:48:27 Voltage Offset Correction: v_off_ini = 414.905 uV, v_off_fin = 417.177 uV 16:48:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.560 uVs 16:48:27 Integrated Voltage Measurement... 16:48:36 Voltage Offset Correction: v_off_ini = 418.747 uV, v_off_fin = 399.380 uV 16:48:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.570 uVs 16:48:36 Integrated Voltage Measurement... 16:48:45 Voltage Offset Correction: v_off_ini = 412.637 uV, v_off_fin = 417.020 uV 16:48:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.198 uVs 16:48:49 I1Y Average and RMS of Measurements VT = -206.974 +- 2.187 uVs I1Y = -41.395 +- 0.437 uTm 16:48:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:48:54 Integrated Voltage Measurement... 16:49:03 Voltage Offset Correction: v_off_ini = 401.613 uV, v_off_fin = 408.379 uV 16:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.150 uVs 16:49:03 Integrated Voltage Measurement... 16:49:12 Voltage Offset Correction: v_off_ini = 401.934 uV, v_off_fin = 409.858 uV 16:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.929 uVs 16:49:12 Integrated Voltage Measurement... 16:49:21 Voltage Offset Correction: v_off_ini = 412.041 uV, v_off_fin = 403.732 uV 16:49:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.049 uVs 16:49:21 Integrated Voltage Measurement... 16:49:30 Voltage Offset Correction: v_off_ini = 407.203 uV, v_off_fin = 414.143 uV 16:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.109 uVs 16:49:30 Integrated Voltage Measurement... 16:49:39 Voltage Offset Correction: v_off_ini = 399.368 uV, v_off_fin = 402.109 uV 16:49:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.980 uVs 16:49:39 Integrated Voltage Measurement... 16:49:48 Voltage Offset Correction: v_off_ini = 417.608 uV, v_off_fin = 424.037 uV 16:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.942 uVs 16:49:51 I2X Average and RMS of Measurements VT = -41.526 +- 6.683 uVs I2X = 3.821 +- 0.615 uTm^2 16:49:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:49:56 Integrated Voltage Measurement... 16:50:05 Voltage Offset Correction: v_off_ini = 425.098 uV, v_off_fin = 408.710 uV 16:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.509 uVs 16:50:05 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = 404.255 uV, v_off_fin = 399.583 uV 16:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.780 uVs 16:50:14 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = 402.645 uV, v_off_fin = 401.899 uV 16:50:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.288 uVs 16:50:23 Integrated Voltage Measurement... 16:50:32 Voltage Offset Correction: v_off_ini = 387.746 uV, v_off_fin = 402.478 uV 16:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.210 uVs 16:50:32 Integrated Voltage Measurement... 16:50:41 Voltage Offset Correction: v_off_ini = 394.271 uV, v_off_fin = 393.083 uV 16:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.852 uVs 16:50:41 Integrated Voltage Measurement... 16:50:50 Voltage Offset Correction: v_off_ini = 405.015 uV, v_off_fin = 398.393 uV 16:50:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.337 uVs 16:50:52 I2Y Average and RMS of Measurements VT = -200.163 +- 10.028 uVs I2Y = -18.415 +- 0.923 uTm^2 16:50:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:51:01 Integrated Voltage Measurement... 16:51:10 Voltage Offset Correction: v_off_ini = 390.350 uV, v_off_fin = 395.424 uV 16:51:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -63.686 uVs 16:51:10 Integrated Voltage Measurement... 16:51:19 Voltage Offset Correction: v_off_ini = 386.253 uV, v_off_fin = 392.700 uV 16:51:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.781 uVs 16:51:19 Integrated Voltage Measurement... 16:51:28 Voltage Offset Correction: v_off_ini = 387.669 uV, v_off_fin = 395.400 uV 16:51:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.540 uVs 16:51:28 Integrated Voltage Measurement... 16:51:37 Voltage Offset Correction: v_off_ini = 384.231 uV, v_off_fin = 396.117 uV 16:51:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.779 uVs 16:51:37 Integrated Voltage Measurement... 16:51:46 Voltage Offset Correction: v_off_ini = 387.099 uV, v_off_fin = 387.132 uV 16:51:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.066 uVs 16:51:46 Integrated Voltage Measurement... 16:51:55 Voltage Offset Correction: v_off_ini = 395.625 uV, v_off_fin = 405.338 uV 16:51:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.219 uVs 16:51:59 I1X Average and RMS of Measurements VT = -58.678 +- 8.519 uVs I1X = 11.736 +- 1.704 uTm 16:52:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:52:06 Integrated Voltage Measurement... 16:52:15 Voltage Offset Correction: v_off_ini = 391.079 uV, v_off_fin = 388.846 uV 16:52:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.662 uVs 16:52:15 Integrated Voltage Measurement... 16:52:24 Voltage Offset Correction: v_off_ini = 404.665 uV, v_off_fin = 413.213 uV 16:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.905 uVs 16:52:24 Integrated Voltage Measurement... 16:52:33 Voltage Offset Correction: v_off_ini = 389.323 uV, v_off_fin = 391.123 uV 16:52:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.998 uVs 16:52:33 Integrated Voltage Measurement... 16:52:42 Voltage Offset Correction: v_off_ini = 388.302 uV, v_off_fin = 408.386 uV 16:52:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.759 uVs 16:52:42 Integrated Voltage Measurement... 16:52:51 Voltage Offset Correction: v_off_ini = 396.189 uV, v_off_fin = 392.609 uV 16:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.973 uVs 16:52:51 Integrated Voltage Measurement... 16:53:00 Voltage Offset Correction: v_off_ini = 399.777 uV, v_off_fin = 417.365 uV 16:53:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.898 uVs 16:53:04 I1Y Average and RMS of Measurements VT = -208.366 +- 0.659 uVs I1Y = -41.673 +- 0.132 uTm 16:53:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:53:09 Integrated Voltage Measurement... 16:53:18 Voltage Offset Correction: v_off_ini = 399.708 uV, v_off_fin = 400.205 uV 16:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.574 uVs 16:53:18 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = 406.589 uV, v_off_fin = 408.147 uV 16:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.130 uVs 16:53:27 Integrated Voltage Measurement... 16:53:36 Voltage Offset Correction: v_off_ini = 394.027 uV, v_off_fin = 381.606 uV 16:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.322 uVs 16:53:36 Integrated Voltage Measurement... 16:53:45 Voltage Offset Correction: v_off_ini = 394.132 uV, v_off_fin = 410.701 uV 16:53:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.965 uVs 16:53:45 Integrated Voltage Measurement... 16:53:54 Voltage Offset Correction: v_off_ini = 403.495 uV, v_off_fin = 391.145 uV 16:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.387 uVs 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = 398.101 uV, v_off_fin = 402.166 uV 16:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.405 uVs 16:54:05 I2X Average and RMS of Measurements VT = -45.964 +- 4.883 uVs I2X = 4.229 +- 0.449 uTm^2 16:54:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:54:11 Integrated Voltage Measurement... 16:54:20 Voltage Offset Correction: v_off_ini = 411.542 uV, v_off_fin = 401.760 uV 16:54:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.277 uVs 16:54:20 Integrated Voltage Measurement... 16:54:29 Voltage Offset Correction: v_off_ini = 403.413 uV, v_off_fin = 406.400 uV 16:54:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.456 uVs 16:54:29 Integrated Voltage Measurement... 16:54:38 Voltage Offset Correction: v_off_ini = 392.801 uV, v_off_fin = 397.448 uV 16:54:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.043 uVs 16:54:38 Integrated Voltage Measurement... 16:54:47 Voltage Offset Correction: v_off_ini = 393.186 uV, v_off_fin = 395.470 uV 16:54:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.655 uVs 16:54:47 Integrated Voltage Measurement... 16:54:56 Voltage Offset Correction: v_off_ini = 400.621 uV, v_off_fin = 409.614 uV 16:54:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.549 uVs 16:54:56 Integrated Voltage Measurement... 16:55:05 Voltage Offset Correction: v_off_ini = 407.508 uV, v_off_fin = 404.923 uV 16:55:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.141 uVs 16:55:07 I2Y Average and RMS of Measurements VT = -199.687 +- 6.468 uVs I2Y = -18.371 +- 0.595 uTm^2 16:55:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:15 Integrated Voltage Measurement... 16:55:24 Voltage Offset Correction: v_off_ini = 416.196 uV, v_off_fin = 392.178 uV 16:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -64.641 uVs 16:55:25 Integrated Voltage Measurement... 16:55:33 Voltage Offset Correction: v_off_ini = 398.887 uV, v_off_fin = 394.422 uV 16:55:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.007 uVs 16:55:34 Integrated Voltage Measurement... 16:55:43 Voltage Offset Correction: v_off_ini = 400.655 uV, v_off_fin = 404.796 uV 16:55:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.963 uVs 16:55:43 Integrated Voltage Measurement... 16:55:52 Voltage Offset Correction: v_off_ini = 409.266 uV, v_off_fin = 395.188 uV 16:55:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.624 uVs 16:55:52 Integrated Voltage Measurement... 16:56:01 Voltage Offset Correction: v_off_ini = 407.401 uV, v_off_fin = 413.030 uV 16:56:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.869 uVs 16:56:01 Integrated Voltage Measurement... 16:56:10 Voltage Offset Correction: v_off_ini = 425.793 uV, v_off_fin = 417.662 uV 16:56:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.486 uVs 16:56:14 I1X Average and RMS of Measurements VT = -71.765 +- 3.531 uVs I1X = 14.353 +- 0.706 uTm 16:56:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:21 Integrated Voltage Measurement... 16:56:30 Voltage Offset Correction: v_off_ini = 431.510 uV, v_off_fin = 402.187 uV 16:56:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.176 uVs 16:56:30 Integrated Voltage Measurement... 16:56:39 Voltage Offset Correction: v_off_ini = 427.534 uV, v_off_fin = 437.032 uV 16:56:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.891 uVs 16:56:39 Integrated Voltage Measurement... 16:56:48 Voltage Offset Correction: v_off_ini = 424.815 uV, v_off_fin = 409.536 uV 16:56:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.302 uVs 16:56:48 Integrated Voltage Measurement... 16:56:57 Voltage Offset Correction: v_off_ini = 431.922 uV, v_off_fin = 431.753 uV 16:56:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.626 uVs 16:56:57 Integrated Voltage Measurement... 16:57:06 Voltage Offset Correction: v_off_ini = 426.206 uV, v_off_fin = 415.811 uV 16:57:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.852 uVs 16:57:06 Integrated Voltage Measurement... 16:57:15 Voltage Offset Correction: v_off_ini = 421.671 uV, v_off_fin = 450.498 uV 16:57:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.095 uVs 16:57:19 I1Y Average and RMS of Measurements VT = -214.657 +- 5.416 uVs I1Y = -42.931 +- 1.083 uTm 16:57:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:24 Integrated Voltage Measurement... 16:57:33 Voltage Offset Correction: v_off_ini = 411.770 uV, v_off_fin = 415.465 uV 16:57:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.695 uVs 16:57:33 Integrated Voltage Measurement... 16:57:42 Voltage Offset Correction: v_off_ini = 432.382 uV, v_off_fin = 436.116 uV 16:57:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.435 uVs 16:57:42 Integrated Voltage Measurement... 16:57:51 Voltage Offset Correction: v_off_ini = 415.087 uV, v_off_fin = 411.911 uV 16:57:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.623 uVs 16:57:51 Integrated Voltage Measurement... 16:58:00 Voltage Offset Correction: v_off_ini = 422.997 uV, v_off_fin = 418.569 uV 16:58:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.196 uVs 16:58:00 Integrated Voltage Measurement... 16:58:09 Voltage Offset Correction: v_off_ini = 419.703 uV, v_off_fin = 419.659 uV 16:58:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.328 uVs 16:58:09 Integrated Voltage Measurement... 16:58:18 Voltage Offset Correction: v_off_ini = 427.931 uV, v_off_fin = 434.144 uV 16:58:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.223 uVs 16:58:20 I2X Average and RMS of Measurements VT = -61.917 +- 2.639 uVs I2X = 5.696 +- 0.243 uTm^2 16:58:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:26 Integrated Voltage Measurement... 16:58:35 Voltage Offset Correction: v_off_ini = 428.393 uV, v_off_fin = 420.294 uV 16:58:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.073 uVs 16:58:35 Integrated Voltage Measurement... 16:58:44 Voltage Offset Correction: v_off_ini = 432.621 uV, v_off_fin = 433.415 uV 16:58:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.295 uVs 16:58:44 Integrated Voltage Measurement... 16:58:53 Voltage Offset Correction: v_off_ini = 433.305 uV, v_off_fin = 431.546 uV 16:58:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.234 uVs 16:58:53 Integrated Voltage Measurement... 16:59:02 Voltage Offset Correction: v_off_ini = 436.165 uV, v_off_fin = 428.423 uV 16:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.688 uVs 16:59:02 Integrated Voltage Measurement... 16:59:11 Voltage Offset Correction: v_off_ini = 437.689 uV, v_off_fin = 428.719 uV 16:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.488 uVs 16:59:11 Integrated Voltage Measurement... 16:59:20 Voltage Offset Correction: v_off_ini = 425.753 uV, v_off_fin = 425.905 uV 16:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.313 uVs 16:59:22 I2Y Average and RMS of Measurements VT = -212.015 +- 2.639 uVs I2Y = -19.505 +- 0.243 uTm^2 16:59:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:59:30 Integrated Voltage Measurement... 16:59:39 Voltage Offset Correction: v_off_ini = 437.292 uV, v_off_fin = 440.762 uV 16:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.079 uVs 16:59:40 Integrated Voltage Measurement... 16:59:48 Voltage Offset Correction: v_off_ini = 430.452 uV, v_off_fin = 430.611 uV 16:59:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.234 uVs 16:59:49 Integrated Voltage Measurement... 16:59:57 Voltage Offset Correction: v_off_ini = 433.271 uV, v_off_fin = 438.240 uV 16:59:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.829 uVs 16:59:58 Integrated Voltage Measurement... 17:00:06 Voltage Offset Correction: v_off_ini = 437.527 uV, v_off_fin = 433.103 uV 17:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.517 uVs 17:00:07 Integrated Voltage Measurement... 17:00:16 Voltage Offset Correction: v_off_ini = 437.854 uV, v_off_fin = 432.020 uV 17:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.239 uVs 17:00:16 Integrated Voltage Measurement... 17:00:25 Voltage Offset Correction: v_off_ini = 435.006 uV, v_off_fin = 437.677 uV 17:00:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.244 uVs 17:00:29 I1X Average and RMS of Measurements VT = -71.024 +- 8.356 uVs I1X = 14.205 +- 1.672 uTm 17:00:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:00:36 Integrated Voltage Measurement... 17:00:44 Voltage Offset Correction: v_off_ini = 432.395 uV, v_off_fin = 417.455 uV 17:00:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -218.616 uVs 17:00:45 Integrated Voltage Measurement... 17:00:53 Voltage Offset Correction: v_off_ini = 437.563 uV, v_off_fin = 439.058 uV 17:00:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.083 uVs 17:00:54 Integrated Voltage Measurement... 17:01:02 Voltage Offset Correction: v_off_ini = 426.090 uV, v_off_fin = 412.581 uV 17:01:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.382 uVs 17:01:03 Integrated Voltage Measurement... 17:01:11 Voltage Offset Correction: v_off_ini = 412.276 uV, v_off_fin = 428.744 uV 17:01:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.526 uVs 17:01:11 Integrated Voltage Measurement... 17:01:20 Voltage Offset Correction: v_off_ini = 424.094 uV, v_off_fin = 413.605 uV 17:01:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.037 uVs 17:01:20 Integrated Voltage Measurement... 17:01:29 Voltage Offset Correction: v_off_ini = 416.516 uV, v_off_fin = 436.310 uV 17:01:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.022 uVs 17:01:34 I1Y Average and RMS of Measurements VT = -219.778 +- 1.946 uVs I1Y = -43.953 +- 0.388 uTm 17:01:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:01:39 Integrated Voltage Measurement... 17:01:48 Voltage Offset Correction: v_off_ini = 423.318 uV, v_off_fin = 417.650 uV 17:01:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.271 uVs 17:01:48 Integrated Voltage Measurement... 17:01:57 Voltage Offset Correction: v_off_ini = 429.040 uV, v_off_fin = 429.151 uV 17:01:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.784 uVs 17:01:57 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = 423.768 uV, v_off_fin = 411.827 uV 17:02:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.571 uVs 17:02:06 Integrated Voltage Measurement... 17:02:15 Voltage Offset Correction: v_off_ini = 423.035 uV, v_off_fin = 424.192 uV 17:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.165 uVs 17:02:15 Integrated Voltage Measurement... 17:02:24 Voltage Offset Correction: v_off_ini = 443.640 uV, v_off_fin = 427.254 uV 17:02:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.968 uVs 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = 422.196 uV, v_off_fin = 435.174 uV 17:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.708 uVs 17:02:35 I2X Average and RMS of Measurements VT = -58.411 +- 7.734 uVs I2X = 5.374 +- 0.712 uTm^2 17:02:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:02:41 Integrated Voltage Measurement... 17:02:49 Voltage Offset Correction: v_off_ini = 419.304 uV, v_off_fin = 421.644 uV 17:02:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.728 uVs 17:02:50 Integrated Voltage Measurement... 17:02:59 Voltage Offset Correction: v_off_ini = 431.175 uV, v_off_fin = 418.428 uV 17:02:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.979 uVs 17:02:59 Integrated Voltage Measurement... 17:03:08 Voltage Offset Correction: v_off_ini = 418.940 uV, v_off_fin = 426.133 uV 17:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.548 uVs 17:03:08 Integrated Voltage Measurement... 17:03:17 Voltage Offset Correction: v_off_ini = 426.413 uV, v_off_fin = 415.239 uV 17:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.085 uVs 17:03:17 Integrated Voltage Measurement... 17:03:26 Voltage Offset Correction: v_off_ini = 416.550 uV, v_off_fin = 424.883 uV 17:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.591 uVs 17:03:26 Integrated Voltage Measurement... 17:03:35 Voltage Offset Correction: v_off_ini = 424.377 uV, v_off_fin = 425.009 uV 17:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.309 uVs 17:03:37 I2Y Average and RMS of Measurements VT = -224.540 +- 6.663 uVs I2Y = -20.658 +- 0.613 uTm^2 17:03:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:03:45 Integrated Voltage Measurement... 17:03:54 Voltage Offset Correction: v_off_ini = 432.237 uV, v_off_fin = 410.284 uV 17:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.275 uVs 17:03:54 Integrated Voltage Measurement... 17:04:03 Voltage Offset Correction: v_off_ini = 411.867 uV, v_off_fin = 407.792 uV 17:04:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.477 uVs 17:04:03 Integrated Voltage Measurement... 17:04:12 Voltage Offset Correction: v_off_ini = 414.579 uV, v_off_fin = 406.902 uV 17:04:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.634 uVs 17:04:12 Integrated Voltage Measurement... 17:04:21 Voltage Offset Correction: v_off_ini = 417.371 uV, v_off_fin = 412.085 uV 17:04:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.495 uVs 17:04:22 Integrated Voltage Measurement... 17:04:30 Voltage Offset Correction: v_off_ini = 407.940 uV, v_off_fin = 408.272 uV 17:04:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.537 uVs 17:04:31 Integrated Voltage Measurement... 17:04:39 Voltage Offset Correction: v_off_ini = 401.153 uV, v_off_fin = 410.601 uV 17:04:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.181 uVs 17:04:44 I1X Average and RMS of Measurements VT = -65.267 +- 3.795 uVs I1X = 13.053 +- 0.759 uTm 17:04:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:04:50 Integrated Voltage Measurement... 17:04:59 Voltage Offset Correction: v_off_ini = 403.787 uV, v_off_fin = 408.590 uV 17:04:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.693 uVs 17:04:59 Integrated Voltage Measurement... 17:05:08 Voltage Offset Correction: v_off_ini = 409.376 uV, v_off_fin = 426.932 uV 17:05:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.104 uVs 17:05:08 Integrated Voltage Measurement... 17:05:17 Voltage Offset Correction: v_off_ini = 395.302 uV, v_off_fin = 391.580 uV 17:05:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.025 uVs 17:05:17 Integrated Voltage Measurement... 17:05:26 Voltage Offset Correction: v_off_ini = 409.427 uV, v_off_fin = 418.955 uV 17:05:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.430 uVs 17:05:26 Integrated Voltage Measurement... 17:05:35 Voltage Offset Correction: v_off_ini = 413.363 uV, v_off_fin = 401.299 uV 17:05:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.348 uVs 17:05:35 Integrated Voltage Measurement... 17:05:44 Voltage Offset Correction: v_off_ini = 407.574 uV, v_off_fin = 428.832 uV 17:05:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.786 uVs 17:05:49 I1Y Average and RMS of Measurements VT = -221.064 +- 11.140 uVs I1Y = -44.209 +- 2.227 uTm 17:05:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:05:54 Integrated Voltage Measurement... 17:06:03 Voltage Offset Correction: v_off_ini = 407.115 uV, v_off_fin = 405.907 uV 17:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.279 uVs 17:06:03 Integrated Voltage Measurement... 17:06:12 Voltage Offset Correction: v_off_ini = 421.813 uV, v_off_fin = 423.993 uV 17:06:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.476 uVs 17:06:12 Integrated Voltage Measurement... 17:06:21 Voltage Offset Correction: v_off_ini = 418.313 uV, v_off_fin = 410.532 uV 17:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.453 uVs 17:06:21 Integrated Voltage Measurement... 17:06:30 Voltage Offset Correction: v_off_ini = 421.651 uV, v_off_fin = 426.215 uV 17:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.360 uVs 17:06:30 Integrated Voltage Measurement... 17:06:39 Voltage Offset Correction: v_off_ini = 416.821 uV, v_off_fin = 414.891 uV 17:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.537 uVs 17:06:39 Integrated Voltage Measurement... 17:06:48 Voltage Offset Correction: v_off_ini = 419.396 uV, v_off_fin = 428.653 uV 17:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.740 uVs 17:06:50 I2X Average and RMS of Measurements VT = -57.474 +- 3.854 uVs I2X = 5.288 +- 0.355 uTm^2 17:06:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:06:55 Integrated Voltage Measurement... 17:07:04 Voltage Offset Correction: v_off_ini = 418.066 uV, v_off_fin = 409.445 uV 17:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.301 uVs 17:07:05 Integrated Voltage Measurement... 17:07:13 Voltage Offset Correction: v_off_ini = 420.938 uV, v_off_fin = 424.874 uV 17:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.520 uVs 17:07:14 Integrated Voltage Measurement... 17:07:23 Voltage Offset Correction: v_off_ini = 415.668 uV, v_off_fin = 422.143 uV 17:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.760 uVs 17:07:23 Integrated Voltage Measurement... 17:07:32 Voltage Offset Correction: v_off_ini = 420.108 uV, v_off_fin = 417.287 uV 17:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.730 uVs 17:07:32 Integrated Voltage Measurement... 17:07:41 Voltage Offset Correction: v_off_ini = 415.086 uV, v_off_fin = 411.515 uV 17:07:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.332 uVs 17:07:41 Integrated Voltage Measurement... 17:07:50 Voltage Offset Correction: v_off_ini = 422.703 uV, v_off_fin = 410.781 uV 17:07:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.148 uVs 17:07:52 I2Y Average and RMS of Measurements VT = -231.465 +- 7.635 uVs I2Y = -21.295 +- 0.702 uTm^2 17:08:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:08:13 Integrated Voltage Measurement... 17:08:22 Voltage Offset Correction: v_off_ini = 445.852 uV, v_off_fin = 450.885 uV 17:08:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.726 uVs 17:08:22 Integrated Voltage Measurement... 17:08:31 Voltage Offset Correction: v_off_ini = 438.936 uV, v_off_fin = 439.471 uV 17:08:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.190 uVs 17:08:31 Integrated Voltage Measurement... 17:08:40 Voltage Offset Correction: v_off_ini = 445.528 uV, v_off_fin = 446.671 uV 17:08:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.809 uVs 17:08:40 Integrated Voltage Measurement... 17:08:49 Voltage Offset Correction: v_off_ini = 447.830 uV, v_off_fin = 451.886 uV 17:08:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.459 uVs 17:08:49 Integrated Voltage Measurement... 17:08:58 Voltage Offset Correction: v_off_ini = 426.873 uV, v_off_fin = 436.586 uV 17:08:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.708 uVs 17:08:58 Integrated Voltage Measurement... 17:09:07 Voltage Offset Correction: v_off_ini = 449.109 uV, v_off_fin = 442.534 uV 17:09:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.333 uVs 17:09:12 I1X Average and RMS of Measurements VT = -58.871 +- 6.276 uVs I1X = 11.774 +- 1.255 uTm 17:09:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:09:18 Integrated Voltage Measurement... 17:09:27 Voltage Offset Correction: v_off_ini = 463.381 uV, v_off_fin = 454.169 uV 17:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.110 uVs 17:09:27 Integrated Voltage Measurement... 17:09:36 Voltage Offset Correction: v_off_ini = 468.751 uV, v_off_fin = 473.969 uV 17:09:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.362 uVs 17:09:36 Integrated Voltage Measurement... 17:09:45 Voltage Offset Correction: v_off_ini = 454.155 uV, v_off_fin = 449.888 uV 17:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.770 uVs 17:09:45 Integrated Voltage Measurement... 17:09:54 Voltage Offset Correction: v_off_ini = 456.369 uV, v_off_fin = 476.171 uV 17:09:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 214.201 uVs 17:09:54 Integrated Voltage Measurement... 17:10:03 Voltage Offset Correction: v_off_ini = 451.160 uV, v_off_fin = 443.774 uV 17:10:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.775 uVs 17:10:03 Integrated Voltage Measurement... 17:10:12 Voltage Offset Correction: v_off_ini = 445.885 uV, v_off_fin = 474.243 uV 17:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.411 uVs 17:10:17 I1Y Average and RMS of Measurements VT = -217.271 +- 4.548 uVs I1Y = -43.455 +- 0.909 uTm 17:10:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:10:24 Integrated Voltage Measurement... 17:10:33 Voltage Offset Correction: v_off_ini = 461.467 uV, v_off_fin = 455.720 uV 17:10:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.762 uVs 17:10:33 Integrated Voltage Measurement... 17:10:42 Voltage Offset Correction: v_off_ini = 477.149 uV, v_off_fin = 481.242 uV 17:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.566 uVs 17:10:42 Integrated Voltage Measurement... 17:10:51 Voltage Offset Correction: v_off_ini = 468.687 uV, v_off_fin = 464.781 uV 17:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.967 uVs 17:10:51 Integrated Voltage Measurement... 17:11:00 Voltage Offset Correction: v_off_ini = 474.446 uV, v_off_fin = 474.116 uV 17:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.115 uVs 17:11:00 Integrated Voltage Measurement... 17:11:09 Voltage Offset Correction: v_off_ini = 475.392 uV, v_off_fin = 471.236 uV 17:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.558 uVs 17:11:09 Integrated Voltage Measurement... 17:11:18 Voltage Offset Correction: v_off_ini = 448.468 uV, v_off_fin = 460.585 uV 17:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.571 uVs 17:11:21 I2X Average and RMS of Measurements VT = -55.423 +- 5.617 uVs I2X = 5.099 +- 0.517 uTm^2 17:11:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:11:29 Integrated Voltage Measurement... 17:11:37 Voltage Offset Correction: v_off_ini = 462.898 uV, v_off_fin = 458.578 uV 17:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.583 uVs 17:11:38 Integrated Voltage Measurement... 17:11:47 Voltage Offset Correction: v_off_ini = 464.251 uV, v_off_fin = 459.167 uV 17:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.682 uVs 17:11:47 Integrated Voltage Measurement... 17:11:56 Voltage Offset Correction: v_off_ini = 461.199 uV, v_off_fin = 460.986 uV 17:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.656 uVs 17:11:56 Integrated Voltage Measurement... 17:12:05 Voltage Offset Correction: v_off_ini = 453.532 uV, v_off_fin = 457.179 uV 17:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.414 uVs 17:12:05 Integrated Voltage Measurement... 17:12:14 Voltage Offset Correction: v_off_ini = 464.075 uV, v_off_fin = 459.254 uV 17:12:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.440 uVs 17:12:14 Integrated Voltage Measurement... 17:12:23 Voltage Offset Correction: v_off_ini = 461.519 uV, v_off_fin = 455.683 uV 17:12:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.405 uVs 17:12:25 I2Y Average and RMS of Measurements VT = -219.530 +- 2.302 uVs I2Y = -20.197 +- 0.212 uTm^2 17:12:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:12:34 Integrated Voltage Measurement... 17:12:43 Voltage Offset Correction: v_off_ini = 472.469 uV, v_off_fin = 459.905 uV 17:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.260 uVs 17:12:43 Integrated Voltage Measurement... 17:12:52 Voltage Offset Correction: v_off_ini = 464.346 uV, v_off_fin = 451.650 uV 17:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 80.488 uVs 17:12:52 Integrated Voltage Measurement... 17:13:01 Voltage Offset Correction: v_off_ini = 463.400 uV, v_off_fin = 459.954 uV 17:13:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.072 uVs 17:13:01 Integrated Voltage Measurement... 17:13:10 Voltage Offset Correction: v_off_ini = 458.803 uV, v_off_fin = 465.021 uV 17:13:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.004 uVs 17:13:10 Integrated Voltage Measurement... 17:13:19 Voltage Offset Correction: v_off_ini = 462.220 uV, v_off_fin = 455.841 uV 17:13:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.038 uVs 17:13:19 Integrated Voltage Measurement... 17:13:28 Voltage Offset Correction: v_off_ini = 463.401 uV, v_off_fin = 462.129 uV 17:13:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.615 uVs 17:13:32 I1X Average and RMS of Measurements VT = -72.746 +- 6.461 uVs I1X = 14.550 +- 1.293 uTm 17:13:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:13:39 Integrated Voltage Measurement... 17:13:48 Voltage Offset Correction: v_off_ini = 467.024 uV, v_off_fin = 451.071 uV 17:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.756 uVs 17:13:48 Integrated Voltage Measurement... 17:13:57 Voltage Offset Correction: v_off_ini = 455.443 uV, v_off_fin = 476.090 uV 17:13:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.482 uVs 17:13:57 Integrated Voltage Measurement... 17:14:06 Voltage Offset Correction: v_off_ini = 460.309 uV, v_off_fin = 463.375 uV 17:14:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.552 uVs 17:14:06 Integrated Voltage Measurement... 17:14:15 Voltage Offset Correction: v_off_ini = 459.042 uV, v_off_fin = 473.701 uV 17:14:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.134 uVs 17:14:15 Integrated Voltage Measurement... 17:14:24 Voltage Offset Correction: v_off_ini = 463.187 uV, v_off_fin = 451.872 uV 17:14:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.981 uVs 17:14:24 Integrated Voltage Measurement... 17:14:33 Voltage Offset Correction: v_off_ini = 467.520 uV, v_off_fin = 475.483 uV 17:14:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.337 uVs 17:14:37 I1Y Average and RMS of Measurements VT = -210.207 +- 3.483 uVs I1Y = -42.041 +- 0.697 uTm 17:14:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:14:45 Integrated Voltage Measurement... 17:14:54 Voltage Offset Correction: v_off_ini = 463.708 uV, v_off_fin = 468.041 uV 17:14:54 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.358 uVs 17:14:54 Integrated Voltage Measurement... 17:15:03 Voltage Offset Correction: v_off_ini = 477.543 uV, v_off_fin = 482.260 uV 17:15:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.822 uVs 17:15:03 Integrated Voltage Measurement... 17:15:12 Voltage Offset Correction: v_off_ini = 478.614 uV, v_off_fin = 465.360 uV 17:15:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.275 uVs 17:15:12 Integrated Voltage Measurement... 17:15:21 Voltage Offset Correction: v_off_ini = 474.718 uV, v_off_fin = 486.681 uV 17:15:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.326 uVs 17:15:21 Integrated Voltage Measurement... 17:15:30 Voltage Offset Correction: v_off_ini = 466.084 uV, v_off_fin = 466.188 uV 17:15:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.140 uVs 17:15:30 Integrated Voltage Measurement... 17:15:39 Voltage Offset Correction: v_off_ini = 481.368 uV, v_off_fin = 478.873 uV 17:15:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.963 uVs 17:15:42 I2X Average and RMS of Measurements VT = -55.647 +- 6.364 uVs I2X = 5.119 +- 0.585 uTm^2 17:15:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:15:49 Integrated Voltage Measurement... 17:15:58 Voltage Offset Correction: v_off_ini = 482.103 uV, v_off_fin = 470.424 uV 17:15:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.470 uVs 17:15:58 Integrated Voltage Measurement... 17:16:07 Voltage Offset Correction: v_off_ini = 477.031 uV, v_off_fin = 473.040 uV 17:16:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.143 uVs 17:16:07 Integrated Voltage Measurement... 17:16:16 Voltage Offset Correction: v_off_ini = 484.118 uV, v_off_fin = 478.310 uV 17:16:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.312 uVs 17:16:16 Integrated Voltage Measurement... 17:16:25 Voltage Offset Correction: v_off_ini = 474.512 uV, v_off_fin = 473.661 uV 17:16:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.496 uVs 17:16:25 Integrated Voltage Measurement... 17:16:34 Voltage Offset Correction: v_off_ini = 471.614 uV, v_off_fin = 477.639 uV 17:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.961 uVs 17:16:35 Integrated Voltage Measurement... 17:16:44 Voltage Offset Correction: v_off_ini = 488.100 uV, v_off_fin = 473.485 uV 17:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.039 uVs 17:16:46 I2Y Average and RMS of Measurements VT = -210.570 +- 7.364 uVs I2Y = -19.372 +- 0.677 uTm^2 17:16:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:55 Integrated Voltage Measurement... 17:17:04 Voltage Offset Correction: v_off_ini = 487.935 uV, v_off_fin = 484.461 uV 17:17:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.489 uVs 17:17:04 Integrated Voltage Measurement... 17:17:13 Voltage Offset Correction: v_off_ini = 487.065 uV, v_off_fin = 475.154 uV 17:17:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.640 uVs 17:17:13 Integrated Voltage Measurement... 17:17:22 Voltage Offset Correction: v_off_ini = 475.962 uV, v_off_fin = 476.922 uV 17:17:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.968 uVs 17:17:22 Integrated Voltage Measurement... 17:17:31 Voltage Offset Correction: v_off_ini = 490.849 uV, v_off_fin = 490.176 uV 17:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.659 uVs 17:17:31 Integrated Voltage Measurement... 17:17:40 Voltage Offset Correction: v_off_ini = 480.440 uV, v_off_fin = 485.093 uV 17:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.328 uVs 17:17:40 Integrated Voltage Measurement... 17:17:49 Voltage Offset Correction: v_off_ini = 489.128 uV, v_off_fin = 492.983 uV 17:17:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.262 uVs 17:17:53 I1X Average and RMS of Measurements VT = -66.391 +- 5.613 uVs I1X = 13.279 +- 1.123 uTm 17:17:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:00 Integrated Voltage Measurement... 17:18:09 Voltage Offset Correction: v_off_ini = 477.315 uV, v_off_fin = 465.683 uV 17:18:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.940 uVs 17:18:09 Integrated Voltage Measurement... 17:18:18 Voltage Offset Correction: v_off_ini = 481.810 uV, v_off_fin = 489.564 uV 17:18:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.623 uVs 17:18:18 Integrated Voltage Measurement... 17:18:27 Voltage Offset Correction: v_off_ini = 491.172 uV, v_off_fin = 482.647 uV 17:18:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.244 uVs 17:18:27 Integrated Voltage Measurement... 17:18:36 Voltage Offset Correction: v_off_ini = 496.127 uV, v_off_fin = 505.486 uV 17:18:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.310 uVs 17:18:36 Integrated Voltage Measurement... 17:18:45 Voltage Offset Correction: v_off_ini = 500.310 uV, v_off_fin = 489.219 uV 17:18:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.233 uVs 17:18:45 Integrated Voltage Measurement... 17:18:54 Voltage Offset Correction: v_off_ini = 483.407 uV, v_off_fin = 490.058 uV 17:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.975 uVs 17:18:58 I1Y Average and RMS of Measurements VT = -207.221 +- 5.123 uVs I1Y = -41.445 +- 1.026 uTm 17:19:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:06 Integrated Voltage Measurement... 17:19:15 Voltage Offset Correction: v_off_ini = 476.499 uV, v_off_fin = 482.388 uV 17:19:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.904 uVs 17:19:15 Integrated Voltage Measurement... 17:19:24 Voltage Offset Correction: v_off_ini = 496.765 uV, v_off_fin = 488.458 uV 17:19:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.460 uVs 17:19:24 Integrated Voltage Measurement... 17:19:33 Voltage Offset Correction: v_off_ini = 498.033 uV, v_off_fin = 493.326 uV 17:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.622 uVs 17:19:33 Integrated Voltage Measurement... 17:19:42 Voltage Offset Correction: v_off_ini = 491.566 uV, v_off_fin = 496.938 uV 17:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.451 uVs 17:19:42 Integrated Voltage Measurement... 17:19:51 Voltage Offset Correction: v_off_ini = 489.816 uV, v_off_fin = 485.706 uV 17:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.437 uVs 17:19:51 Integrated Voltage Measurement... 17:20:00 Voltage Offset Correction: v_off_ini = 484.822 uV, v_off_fin = 502.576 uV 17:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.245 uVs 17:20:02 I2X Average and RMS of Measurements VT = -67.186 +- 6.693 uVs I2X = 6.181 +- 0.616 uTm^2 17:20:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:10 Integrated Voltage Measurement... 17:20:19 Voltage Offset Correction: v_off_ini = 488.679 uV, v_off_fin = 497.140 uV 17:20:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.110 uVs 17:20:19 Integrated Voltage Measurement... 17:20:28 Voltage Offset Correction: v_off_ini = 482.698 uV, v_off_fin = 486.241 uV 17:20:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.212 uVs 17:20:28 Integrated Voltage Measurement... 17:20:37 Voltage Offset Correction: v_off_ini = 487.339 uV, v_off_fin = 479.195 uV 17:20:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.819 uVs 17:20:37 Integrated Voltage Measurement... 17:20:46 Voltage Offset Correction: v_off_ini = 488.524 uV, v_off_fin = 491.097 uV 17:20:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.762 uVs 17:20:46 Integrated Voltage Measurement... 17:20:55 Voltage Offset Correction: v_off_ini = 482.775 uV, v_off_fin = 480.684 uV 17:20:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.431 uVs 17:20:55 Integrated Voltage Measurement... 17:21:04 Voltage Offset Correction: v_off_ini = 489.823 uV, v_off_fin = 485.894 uV 17:21:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.082 uVs 17:21:07 I2Y Average and RMS of Measurements VT = -212.402 +- 4.044 uVs I2Y = -19.541 +- 0.372 uTm^2 17:21:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:21:16 Integrated Voltage Measurement... 17:21:25 Voltage Offset Correction: v_off_ini = 490.463 uV, v_off_fin = 485.037 uV 17:21:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -90.184 uVs 17:21:25 Integrated Voltage Measurement... 17:21:34 Voltage Offset Correction: v_off_ini = 484.560 uV, v_off_fin = 483.836 uV 17:21:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.051 uVs 17:21:34 Integrated Voltage Measurement... 17:21:43 Voltage Offset Correction: v_off_ini = 483.132 uV, v_off_fin = 474.962 uV 17:21:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.656 uVs 17:21:43 Integrated Voltage Measurement... 17:21:52 Voltage Offset Correction: v_off_ini = 478.621 uV, v_off_fin = 468.930 uV 17:21:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.133 uVs 17:21:52 Integrated Voltage Measurement... 17:22:01 Voltage Offset Correction: v_off_ini = 482.459 uV, v_off_fin = 473.469 uV 17:22:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.838 uVs 17:22:01 Integrated Voltage Measurement... 17:22:10 Voltage Offset Correction: v_off_ini = 472.464 uV, v_off_fin = 469.227 uV 17:22:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.366 uVs 17:22:14 I1X Average and RMS of Measurements VT = -82.205 +- 4.183 uVs I1X = 16.442 +- 0.838 uTm 17:22:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:22:21 Integrated Voltage Measurement... 17:22:30 Voltage Offset Correction: v_off_ini = 466.108 uV, v_off_fin = 450.790 uV 17:22:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.595 uVs 17:22:30 Integrated Voltage Measurement... 17:22:39 Voltage Offset Correction: v_off_ini = 455.194 uV, v_off_fin = 470.681 uV 17:22:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.673 uVs 17:22:39 Integrated Voltage Measurement... 17:22:48 Voltage Offset Correction: v_off_ini = 466.462 uV, v_off_fin = 450.133 uV 17:22:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.046 uVs 17:22:48 Integrated Voltage Measurement... 17:22:57 Voltage Offset Correction: v_off_ini = 453.354 uV, v_off_fin = 476.318 uV 17:22:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.014 uVs 17:22:57 Integrated Voltage Measurement... 17:23:06 Voltage Offset Correction: v_off_ini = 466.993 uV, v_off_fin = 453.379 uV 17:23:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.269 uVs 17:23:06 Integrated Voltage Measurement... 17:23:15 Voltage Offset Correction: v_off_ini = 460.545 uV, v_off_fin = 466.088 uV 17:23:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.930 uVs 17:23:19 I1Y Average and RMS of Measurements VT = -195.421 +- 5.357 uVs I1Y = -39.084 +- 1.071 uTm 17:23:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:23:27 Integrated Voltage Measurement... 17:23:36 Voltage Offset Correction: v_off_ini = 459.381 uV, v_off_fin = 449.914 uV 17:23:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.947 uVs 17:23:36 Integrated Voltage Measurement... 17:23:45 Voltage Offset Correction: v_off_ini = 447.516 uV, v_off_fin = 467.202 uV 17:23:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.658 uVs 17:23:45 Integrated Voltage Measurement... 17:23:54 Voltage Offset Correction: v_off_ini = 458.184 uV, v_off_fin = 450.285 uV 17:23:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.012 uVs 17:23:54 Integrated Voltage Measurement... 17:24:03 Voltage Offset Correction: v_off_ini = 447.155 uV, v_off_fin = 454.863 uV 17:24:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.401 uVs 17:24:03 Integrated Voltage Measurement... 17:24:12 Voltage Offset Correction: v_off_ini = 455.388 uV, v_off_fin = 449.046 uV 17:24:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.305 uVs 17:24:12 Integrated Voltage Measurement... 17:24:21 Voltage Offset Correction: v_off_ini = 449.557 uV, v_off_fin = 456.888 uV 17:24:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.761 uVs 17:24:23 I2X Average and RMS of Measurements VT = -71.181 +- 5.761 uVs I2X = 6.549 +- 0.530 uTm^2 17:24:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:24:31 Integrated Voltage Measurement... 17:24:40 Voltage Offset Correction: v_off_ini = 450.279 uV, v_off_fin = 447.224 uV 17:24:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.597 uVs 17:24:40 Integrated Voltage Measurement... 17:24:49 Voltage Offset Correction: v_off_ini = 449.388 uV, v_off_fin = 446.380 uV 17:24:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.373 uVs 17:24:49 Integrated Voltage Measurement... 17:24:58 Voltage Offset Correction: v_off_ini = 455.571 uV, v_off_fin = 464.852 uV 17:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.243 uVs 17:24:58 Integrated Voltage Measurement... 17:25:07 Voltage Offset Correction: v_off_ini = 456.470 uV, v_off_fin = 462.758 uV 17:25:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.531 uVs 17:25:07 Integrated Voltage Measurement... 17:25:16 Voltage Offset Correction: v_off_ini = 454.095 uV, v_off_fin = 469.367 uV 17:25:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.215 uVs 17:25:16 Integrated Voltage Measurement... 17:25:25 Voltage Offset Correction: v_off_ini = 463.031 uV, v_off_fin = 472.104 uV 17:25:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.844 uVs 17:25:27 I2Y Average and RMS of Measurements VT = -198.800 +- 8.282 uVs I2Y = -18.290 +- 0.762 uTm^2 17:25:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:25:36 Integrated Voltage Measurement... 17:25:45 Voltage Offset Correction: v_off_ini = 474.158 uV, v_off_fin = 462.341 uV 17:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.189 uVs 17:25:45 Integrated Voltage Measurement... 17:25:54 Voltage Offset Correction: v_off_ini = 453.696 uV, v_off_fin = 447.919 uV 17:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.914 uVs 17:25:54 Integrated Voltage Measurement... 17:26:03 Voltage Offset Correction: v_off_ini = 461.429 uV, v_off_fin = 457.172 uV 17:26:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.029 uVs 17:26:03 Integrated Voltage Measurement... 17:26:12 Voltage Offset Correction: v_off_ini = 455.564 uV, v_off_fin = 471.008 uV 17:26:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.505 uVs 17:26:12 Integrated Voltage Measurement... 17:26:21 Voltage Offset Correction: v_off_ini = 460.124 uV, v_off_fin = 461.447 uV 17:26:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.758 uVs 17:26:21 Integrated Voltage Measurement... 17:26:30 Voltage Offset Correction: v_off_ini = 460.948 uV, v_off_fin = 461.018 uV 17:26:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.926 uVs 17:26:35 I1X Average and RMS of Measurements VT = -89.720 +- 3.824 uVs I1X = 17.944 +- 0.765 uTm 17:26:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:26:41 Integrated Voltage Measurement... 17:26:50 Voltage Offset Correction: v_off_ini = 461.796 uV, v_off_fin = 451.369 uV 17:26:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.676 uVs 17:26:50 Integrated Voltage Measurement... 17:26:59 Voltage Offset Correction: v_off_ini = 460.901 uV, v_off_fin = 463.934 uV 17:26:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.717 uVs 17:26:59 Integrated Voltage Measurement... 17:27:08 Voltage Offset Correction: v_off_ini = 445.190 uV, v_off_fin = 450.340 uV 17:27:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.377 uVs 17:27:08 Integrated Voltage Measurement... 17:27:17 Voltage Offset Correction: v_off_ini = 457.602 uV, v_off_fin = 466.090 uV 17:27:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.656 uVs 17:27:17 Integrated Voltage Measurement... 17:27:26 Voltage Offset Correction: v_off_ini = 444.869 uV, v_off_fin = 439.265 uV 17:27:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.328 uVs 17:27:26 Integrated Voltage Measurement... 17:27:35 Voltage Offset Correction: v_off_ini = 428.964 uV, v_off_fin = 437.204 uV 17:27:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.176 uVs 17:27:40 I1Y Average and RMS of Measurements VT = -200.322 +- 2.936 uVs I1Y = -40.064 +- 0.587 uTm 17:27:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:27:47 Integrated Voltage Measurement... 17:27:56 Voltage Offset Correction: v_off_ini = 425.247 uV, v_off_fin = 428.496 uV 17:27:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -71.269 uVs 17:27:56 Integrated Voltage Measurement... 17:28:05 Voltage Offset Correction: v_off_ini = 438.703 uV, v_off_fin = 449.357 uV 17:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.250 uVs 17:28:05 Integrated Voltage Measurement... 17:28:14 Voltage Offset Correction: v_off_ini = 443.680 uV, v_off_fin = 436.462 uV 17:28:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.182 uVs 17:28:14 Integrated Voltage Measurement... 17:28:23 Voltage Offset Correction: v_off_ini = 453.280 uV, v_off_fin = 451.460 uV 17:28:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.612 uVs 17:28:23 Integrated Voltage Measurement... 17:28:32 Voltage Offset Correction: v_off_ini = 448.482 uV, v_off_fin = 435.987 uV 17:28:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.214 uVs 17:28:32 Integrated Voltage Measurement... 17:28:41 Voltage Offset Correction: v_off_ini = 441.194 uV, v_off_fin = 455.698 uV 17:28:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.905 uVs 17:28:44 I2X Average and RMS of Measurements VT = -79.572 +- 3.688 uVs I2X = 7.321 +- 0.339 uTm^2 17:28:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:28:51 Integrated Voltage Measurement... 17:29:00 Voltage Offset Correction: v_off_ini = 441.674 uV, v_off_fin = 448.907 uV 17:29:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.026 uVs 17:29:01 Integrated Voltage Measurement... 17:29:09 Voltage Offset Correction: v_off_ini = 450.007 uV, v_off_fin = 445.009 uV 17:29:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.048 uVs 17:29:10 Integrated Voltage Measurement... 17:29:19 Voltage Offset Correction: v_off_ini = 444.621 uV, v_off_fin = 448.067 uV 17:29:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.218 uVs 17:29:19 Integrated Voltage Measurement... 17:29:28 Voltage Offset Correction: v_off_ini = 458.495 uV, v_off_fin = 454.295 uV 17:29:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.969 uVs 17:29:28 Integrated Voltage Measurement... 17:29:37 Voltage Offset Correction: v_off_ini = 452.585 uV, v_off_fin = 455.400 uV 17:29:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.113 uVs 17:29:37 Integrated Voltage Measurement... 17:29:46 Voltage Offset Correction: v_off_ini = 446.710 uV, v_off_fin = 436.683 uV 17:29:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.283 uVs 17:29:48 I2Y Average and RMS of Measurements VT = -200.276 +- 7.410 uVs I2Y = -18.425 +- 0.682 uTm^2 17:29:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:30:00 Integrated Voltage Measurement... 17:30:09 Voltage Offset Correction: v_off_ini = 456.676 uV, v_off_fin = 450.878 uV 17:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.243 uVs 17:30:09 Integrated Voltage Measurement... 17:30:18 Voltage Offset Correction: v_off_ini = 454.202 uV, v_off_fin = 461.373 uV 17:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.304 uVs 17:30:18 Integrated Voltage Measurement... 17:30:27 Voltage Offset Correction: v_off_ini = 460.843 uV, v_off_fin = 454.036 uV 17:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.028 uVs 17:30:27 Integrated Voltage Measurement... 17:30:36 Voltage Offset Correction: v_off_ini = 458.623 uV, v_off_fin = 461.704 uV 17:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.340 uVs 17:30:36 Integrated Voltage Measurement... 17:30:45 Voltage Offset Correction: v_off_ini = 453.688 uV, v_off_fin = 445.538 uV 17:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.625 uVs 17:30:45 Integrated Voltage Measurement... 17:30:54 Voltage Offset Correction: v_off_ini = 463.568 uV, v_off_fin = 460.773 uV 17:30:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.702 uVs 17:30:58 I1X Average and RMS of Measurements VT = -62.207 +- 7.238 uVs I1X = 12.442 +- 1.448 uTm 17:31:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:31:05 Integrated Voltage Measurement... 17:31:14 Voltage Offset Correction: v_off_ini = 445.002 uV, v_off_fin = 447.686 uV 17:31:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.138 uVs 17:31:14 Integrated Voltage Measurement... 17:31:23 Voltage Offset Correction: v_off_ini = 455.629 uV, v_off_fin = 457.208 uV 17:31:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.658 uVs 17:31:23 Integrated Voltage Measurement... 17:31:32 Voltage Offset Correction: v_off_ini = 455.289 uV, v_off_fin = 438.201 uV 17:31:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.752 uVs 17:31:32 Integrated Voltage Measurement... 17:31:41 Voltage Offset Correction: v_off_ini = 453.965 uV, v_off_fin = 460.307 uV 17:31:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.600 uVs 17:31:41 Integrated Voltage Measurement... 17:31:50 Voltage Offset Correction: v_off_ini = 463.350 uV, v_off_fin = 445.362 uV 17:31:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.138 uVs 17:31:50 Integrated Voltage Measurement... 17:31:59 Voltage Offset Correction: v_off_ini = 438.004 uV, v_off_fin = 451.336 uV 17:31:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.929 uVs 17:32:03 I1Y Average and RMS of Measurements VT = -200.036 +- 3.054 uVs I1Y = -40.007 +- 0.611 uTm 17:32:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:32:08 Integrated Voltage Measurement... 17:32:17 Voltage Offset Correction: v_off_ini = 430.688 uV, v_off_fin = 434.796 uV 17:32:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -36.912 uVs 17:32:17 Integrated Voltage Measurement... 17:32:26 Voltage Offset Correction: v_off_ini = 436.896 uV, v_off_fin = 455.655 uV 17:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.326 uVs 17:32:26 Integrated Voltage Measurement... 17:32:35 Voltage Offset Correction: v_off_ini = 439.788 uV, v_off_fin = 436.063 uV 17:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.003 uVs 17:32:35 Integrated Voltage Measurement... 17:32:44 Voltage Offset Correction: v_off_ini = 446.790 uV, v_off_fin = 459.784 uV 17:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.216 uVs 17:32:44 Integrated Voltage Measurement... 17:32:53 Voltage Offset Correction: v_off_ini = 453.600 uV, v_off_fin = 440.540 uV 17:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.621 uVs 17:32:53 Integrated Voltage Measurement... 17:33:02 Voltage Offset Correction: v_off_ini = 447.759 uV, v_off_fin = 464.728 uV 17:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.026 uVs 17:33:05 I2X Average and RMS of Measurements VT = -47.184 +- 5.982 uVs I2X = 4.341 +- 0.550 uTm^2 17:33:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:33:10 Integrated Voltage Measurement... 17:33:19 Voltage Offset Correction: v_off_ini = 450.746 uV, v_off_fin = 448.714 uV 17:33:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.578 uVs 17:33:19 Integrated Voltage Measurement... 17:33:28 Voltage Offset Correction: v_off_ini = 455.415 uV, v_off_fin = 462.118 uV 17:33:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.210 uVs 17:33:28 Integrated Voltage Measurement... 17:33:37 Voltage Offset Correction: v_off_ini = 448.264 uV, v_off_fin = 451.968 uV 17:33:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.697 uVs 17:33:37 Integrated Voltage Measurement... 17:33:46 Voltage Offset Correction: v_off_ini = 449.558 uV, v_off_fin = 450.563 uV 17:33:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.036 uVs 17:33:46 Integrated Voltage Measurement... 17:33:55 Voltage Offset Correction: v_off_ini = 444.749 uV, v_off_fin = 453.776 uV 17:33:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.590 uVs 17:33:55 Integrated Voltage Measurement... 17:34:04 Voltage Offset Correction: v_off_ini = 451.914 uV, v_off_fin = 462.707 uV 17:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.836 uVs 17:34:06 I2Y Average and RMS of Measurements VT = -197.158 +- 5.645 uVs I2Y = -18.139 +- 0.519 uTm^2 17:34:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:34:14 Integrated Voltage Measurement... 17:34:23 Voltage Offset Correction: v_off_ini = 454.209 uV, v_off_fin = 458.702 uV 17:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.020 uVs 17:34:24 Integrated Voltage Measurement... 17:34:32 Voltage Offset Correction: v_off_ini = 452.440 uV, v_off_fin = 466.158 uV 17:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.754 uVs 17:34:33 Integrated Voltage Measurement... 17:34:41 Voltage Offset Correction: v_off_ini = 454.350 uV, v_off_fin = 455.557 uV 17:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.813 uVs 17:34:41 Integrated Voltage Measurement... 17:34:50 Voltage Offset Correction: v_off_ini = 463.899 uV, v_off_fin = 465.639 uV 17:34:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.123 uVs 17:34:51 Integrated Voltage Measurement... 17:34:59 Voltage Offset Correction: v_off_ini = 467.469 uV, v_off_fin = 463.607 uV 17:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.163 uVs 17:34:59 Integrated Voltage Measurement... 17:35:08 Voltage Offset Correction: v_off_ini = 454.517 uV, v_off_fin = 462.068 uV 17:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.506 uVs 17:35:13 I1X Average and RMS of Measurements VT = -66.730 +- 5.403 uVs I1X = 13.346 +- 1.081 uTm 17:35:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:35:19 Integrated Voltage Measurement... 17:35:28 Voltage Offset Correction: v_off_ini = 462.742 uV, v_off_fin = 447.742 uV 17:35:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.122 uVs 17:35:28 Integrated Voltage Measurement... 17:35:37 Voltage Offset Correction: v_off_ini = 467.068 uV, v_off_fin = 476.065 uV 17:35:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.730 uVs 17:35:37 Integrated Voltage Measurement... 17:35:46 Voltage Offset Correction: v_off_ini = 472.335 uV, v_off_fin = 449.358 uV 17:35:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.432 uVs 17:35:46 Integrated Voltage Measurement... 17:35:55 Voltage Offset Correction: v_off_ini = 467.580 uV, v_off_fin = 482.700 uV 17:35:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.349 uVs 17:35:55 Integrated Voltage Measurement... 17:36:04 Voltage Offset Correction: v_off_ini = 471.628 uV, v_off_fin = 452.971 uV 17:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.596 uVs 17:36:04 Integrated Voltage Measurement... 17:36:13 Voltage Offset Correction: v_off_ini = 467.569 uV, v_off_fin = 484.215 uV 17:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.575 uVs 17:36:18 I1Y Average and RMS of Measurements VT = -212.300 +- 5.156 uVs I1Y = -42.460 +- 1.031 uTm 17:36:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:36:23 Integrated Voltage Measurement... 17:36:32 Voltage Offset Correction: v_off_ini = 460.865 uV, v_off_fin = 462.665 uV 17:36:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -48.331 uVs 17:36:32 Integrated Voltage Measurement... 17:36:41 Voltage Offset Correction: v_off_ini = 471.155 uV, v_off_fin = 473.694 uV 17:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.004 uVs 17:36:41 Integrated Voltage Measurement... 17:36:50 Voltage Offset Correction: v_off_ini = 476.649 uV, v_off_fin = 469.837 uV 17:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.489 uVs 17:36:50 Integrated Voltage Measurement... 17:36:59 Voltage Offset Correction: v_off_ini = 456.566 uV, v_off_fin = 477.355 uV 17:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.077 uVs 17:36:59 Integrated Voltage Measurement... 17:37:08 Voltage Offset Correction: v_off_ini = 462.923 uV, v_off_fin = 468.684 uV 17:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.891 uVs 17:37:08 Integrated Voltage Measurement... 17:37:17 Voltage Offset Correction: v_off_ini = 476.258 uV, v_off_fin = 486.058 uV 17:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.537 uVs 17:37:19 I2X Average and RMS of Measurements VT = -56.888 +- 6.292 uVs I2X = 5.234 +- 0.579 uTm^2 17:37:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:37:24 Integrated Voltage Measurement... 17:37:33 Voltage Offset Correction: v_off_ini = 473.087 uV, v_off_fin = 465.785 uV 17:37:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.944 uVs 17:37:33 Integrated Voltage Measurement... 17:37:42 Voltage Offset Correction: v_off_ini = 460.510 uV, v_off_fin = 468.721 uV 17:37:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.443 uVs 17:37:42 Integrated Voltage Measurement... 17:37:51 Voltage Offset Correction: v_off_ini = 465.109 uV, v_off_fin = 467.822 uV 17:37:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.048 uVs 17:37:51 Integrated Voltage Measurement... 17:38:00 Voltage Offset Correction: v_off_ini = 465.266 uV, v_off_fin = 464.067 uV 17:38:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.846 uVs 17:38:00 Integrated Voltage Measurement... 17:38:09 Voltage Offset Correction: v_off_ini = 462.616 uV, v_off_fin = 472.945 uV 17:38:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.822 uVs 17:38:09 Integrated Voltage Measurement... 17:38:18 Voltage Offset Correction: v_off_ini = 476.848 uV, v_off_fin = 463.375 uV 17:38:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.295 uVs 17:38:21 I2Y Average and RMS of Measurements VT = -200.066 +- 1.571 uVs I2Y = -18.406 +- 0.145 uTm^2 17:38:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:29 Integrated Voltage Measurement... 17:38:38 Voltage Offset Correction: v_off_ini = 471.475 uV, v_off_fin = 465.714 uV 17:38:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.728 uVs 17:38:38 Integrated Voltage Measurement... 17:38:47 Voltage Offset Correction: v_off_ini = 474.790 uV, v_off_fin = 471.293 uV 17:38:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.008 uVs 17:38:47 Integrated Voltage Measurement... 17:38:56 Voltage Offset Correction: v_off_ini = 460.879 uV, v_off_fin = 463.008 uV 17:38:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.994 uVs 17:38:56 Integrated Voltage Measurement... 17:39:05 Voltage Offset Correction: v_off_ini = 458.860 uV, v_off_fin = 464.525 uV 17:39:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 68.349 uVs 17:39:05 Integrated Voltage Measurement... 17:39:14 Voltage Offset Correction: v_off_ini = 465.963 uV, v_off_fin = 465.807 uV 17:39:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.170 uVs 17:39:14 Integrated Voltage Measurement... 17:39:23 Voltage Offset Correction: v_off_ini = 461.920 uV, v_off_fin = 458.567 uV 17:39:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.422 uVs 17:39:27 I1X Average and RMS of Measurements VT = -72.945 +- 3.199 uVs I1X = 14.590 +- 0.639 uTm 17:39:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:34 Integrated Voltage Measurement... 17:39:43 Voltage Offset Correction: v_off_ini = 449.528 uV, v_off_fin = 434.682 uV 17:39:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.664 uVs 17:39:43 Integrated Voltage Measurement... 17:39:52 Voltage Offset Correction: v_off_ini = 447.343 uV, v_off_fin = 462.910 uV 17:39:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.844 uVs 17:39:52 Integrated Voltage Measurement... 17:40:01 Voltage Offset Correction: v_off_ini = 455.332 uV, v_off_fin = 447.005 uV 17:40:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.215 uVs 17:40:01 Integrated Voltage Measurement... 17:40:10 Voltage Offset Correction: v_off_ini = 463.656 uV, v_off_fin = 473.833 uV 17:40:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.990 uVs 17:40:10 Integrated Voltage Measurement... 17:40:19 Voltage Offset Correction: v_off_ini = 449.131 uV, v_off_fin = 452.299 uV 17:40:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.939 uVs 17:40:19 Integrated Voltage Measurement... 17:40:28 Voltage Offset Correction: v_off_ini = 458.952 uV, v_off_fin = 461.179 uV 17:40:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.608 uVs 17:40:32 I1Y Average and RMS of Measurements VT = -202.710 +- 2.443 uVs I1Y = -40.542 +- 0.489 uTm 17:40:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:37 Integrated Voltage Measurement... 17:40:46 Voltage Offset Correction: v_off_ini = 465.585 uV, v_off_fin = 451.019 uV 17:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.126 uVs 17:40:46 Integrated Voltage Measurement... 17:40:55 Voltage Offset Correction: v_off_ini = 461.313 uV, v_off_fin = 461.996 uV 17:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.508 uVs 17:40:55 Integrated Voltage Measurement... 17:41:04 Voltage Offset Correction: v_off_ini = 448.029 uV, v_off_fin = 444.346 uV 17:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.686 uVs 17:41:04 Integrated Voltage Measurement... 17:41:13 Voltage Offset Correction: v_off_ini = 454.353 uV, v_off_fin = 464.060 uV 17:41:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.490 uVs 17:41:13 Integrated Voltage Measurement... 17:41:22 Voltage Offset Correction: v_off_ini = 467.080 uV, v_off_fin = 449.418 uV 17:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.770 uVs 17:41:22 Integrated Voltage Measurement... 17:41:31 Voltage Offset Correction: v_off_ini = 456.412 uV, v_off_fin = 463.266 uV 17:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.802 uVs 17:41:34 I2X Average and RMS of Measurements VT = -66.730 +- 3.729 uVs I2X = 6.139 +- 0.343 uTm^2 17:41:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:39 Integrated Voltage Measurement... 17:41:48 Voltage Offset Correction: v_off_ini = 477.815 uV, v_off_fin = 471.900 uV 17:41:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -231.838 uVs 17:41:48 Integrated Voltage Measurement... 17:41:57 Voltage Offset Correction: v_off_ini = 469.702 uV, v_off_fin = 475.602 uV 17:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.061 uVs 17:41:57 Integrated Voltage Measurement... 17:42:06 Voltage Offset Correction: v_off_ini = 468.673 uV, v_off_fin = 465.148 uV 17:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.351 uVs 17:42:06 Integrated Voltage Measurement... 17:42:15 Voltage Offset Correction: v_off_ini = 476.277 uV, v_off_fin = 472.011 uV 17:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.946 uVs 17:42:15 Integrated Voltage Measurement... 17:42:24 Voltage Offset Correction: v_off_ini = 469.475 uV, v_off_fin = 461.372 uV 17:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.229 uVs 17:42:24 Integrated Voltage Measurement... 17:42:33 Voltage Offset Correction: v_off_ini = 474.662 uV, v_off_fin = 474.087 uV 17:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.937 uVs 17:42:36 I2Y Average and RMS of Measurements VT = -209.227 +- 5.455 uVs I2Y = -19.249 +- 0.502 uTm^2 17:42:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:42:44 Integrated Voltage Measurement... 17:42:53 Voltage Offset Correction: v_off_ini = 463.630 uV, v_off_fin = 453.383 uV 17:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -64.088 uVs 17:42:53 Integrated Voltage Measurement... 17:43:02 Voltage Offset Correction: v_off_ini = 464.262 uV, v_off_fin = 459.701 uV 17:43:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.306 uVs 17:43:02 Integrated Voltage Measurement... 17:43:11 Voltage Offset Correction: v_off_ini = 456.631 uV, v_off_fin = 460.733 uV 17:43:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.015 uVs 17:43:11 Integrated Voltage Measurement... 17:43:20 Voltage Offset Correction: v_off_ini = 459.330 uV, v_off_fin = 463.713 uV 17:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.330 uVs 17:43:20 Integrated Voltage Measurement... 17:43:29 Voltage Offset Correction: v_off_ini = 476.720 uV, v_off_fin = 473.071 uV 17:43:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.173 uVs 17:43:29 Integrated Voltage Measurement... 17:43:38 Voltage Offset Correction: v_off_ini = 479.411 uV, v_off_fin = 479.448 uV 17:43:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.685 uVs 17:43:42 I1X Average and RMS of Measurements VT = -74.933 +- 0.736 uVs I1X = 14.987 +- 0.147 uTm 17:43:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:43:49 Integrated Voltage Measurement... 17:43:58 Voltage Offset Correction: v_off_ini = 475.787 uV, v_off_fin = 459.509 uV 17:43:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.526 uVs 17:43:58 Integrated Voltage Measurement... 17:44:07 Voltage Offset Correction: v_off_ini = 468.642 uV, v_off_fin = 472.980 uV 17:44:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.993 uVs 17:44:07 Integrated Voltage Measurement... 17:44:16 Voltage Offset Correction: v_off_ini = 475.762 uV, v_off_fin = 462.393 uV 17:44:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.543 uVs 17:44:16 Integrated Voltage Measurement... 17:44:25 Voltage Offset Correction: v_off_ini = 475.347 uV, v_off_fin = 489.584 uV 17:44:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.093 uVs 17:44:25 Integrated Voltage Measurement... 17:44:34 Voltage Offset Correction: v_off_ini = 465.167 uV, v_off_fin = 465.854 uV 17:44:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.862 uVs 17:44:34 Integrated Voltage Measurement... 17:44:43 Voltage Offset Correction: v_off_ini = 471.004 uV, v_off_fin = 476.021 uV 17:44:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.877 uVs 17:44:47 I1Y Average and RMS of Measurements VT = -212.482 +- 7.514 uVs I1Y = -42.494 +- 1.503 uTm 17:44:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:44:52 Integrated Voltage Measurement... 17:45:01 Voltage Offset Correction: v_off_ini = 466.617 uV, v_off_fin = 459.815 uV 17:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.951 uVs 17:45:01 Integrated Voltage Measurement... 17:45:10 Voltage Offset Correction: v_off_ini = 459.945 uV, v_off_fin = 470.252 uV 17:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.117 uVs 17:45:10 Integrated Voltage Measurement... 17:45:19 Voltage Offset Correction: v_off_ini = 447.512 uV, v_off_fin = 435.375 uV 17:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.442 uVs 17:45:19 Integrated Voltage Measurement... 17:45:28 Voltage Offset Correction: v_off_ini = 438.505 uV, v_off_fin = 455.595 uV 17:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.360 uVs 17:45:28 Integrated Voltage Measurement... 17:45:37 Voltage Offset Correction: v_off_ini = 466.215 uV, v_off_fin = 457.610 uV 17:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.334 uVs 17:45:37 Integrated Voltage Measurement... 17:45:46 Voltage Offset Correction: v_off_ini = 458.039 uV, v_off_fin = 466.277 uV 17:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.691 uVs 17:45:49 I2X Average and RMS of Measurements VT = -67.649 +- 5.640 uVs I2X = 6.224 +- 0.519 uTm^2 17:45:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:45:54 Integrated Voltage Measurement... 17:46:03 Voltage Offset Correction: v_off_ini = 455.227 uV, v_off_fin = 460.036 uV 17:46:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.894 uVs 17:46:03 Integrated Voltage Measurement... 17:46:12 Voltage Offset Correction: v_off_ini = 457.156 uV, v_off_fin = 459.127 uV 17:46:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.300 uVs 17:46:12 Integrated Voltage Measurement... 17:46:21 Voltage Offset Correction: v_off_ini = 457.991 uV, v_off_fin = 438.154 uV 17:46:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.220 uVs 17:46:21 Integrated Voltage Measurement... 17:46:30 Voltage Offset Correction: v_off_ini = 443.955 uV, v_off_fin = 460.296 uV 17:46:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.437 uVs 17:46:30 Integrated Voltage Measurement... 17:46:39 Voltage Offset Correction: v_off_ini = 450.383 uV, v_off_fin = 457.108 uV 17:46:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.029 uVs 17:46:39 Integrated Voltage Measurement... 17:46:48 Voltage Offset Correction: v_off_ini = 447.782 uV, v_off_fin = 448.174 uV 17:46:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.162 uVs 17:46:51 I2Y Average and RMS of Measurements VT = -207.674 +- 2.452 uVs I2Y = -19.106 +- 0.226 uTm^2 17:46:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:46:59 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = 450.013 uV, v_off_fin = 452.375 uV 17:47:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -79.896 uVs 17:47:08 Integrated Voltage Measurement... 17:47:17 Voltage Offset Correction: v_off_ini = 451.160 uV, v_off_fin = 456.945 uV 17:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.535 uVs 17:47:17 Integrated Voltage Measurement... 17:47:26 Voltage Offset Correction: v_off_ini = 454.215 uV, v_off_fin = 457.313 uV 17:47:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.414 uVs 17:47:26 Integrated Voltage Measurement... 17:47:35 Voltage Offset Correction: v_off_ini = 447.569 uV, v_off_fin = 453.590 uV 17:47:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.913 uVs 17:47:35 Integrated Voltage Measurement... 17:47:44 Voltage Offset Correction: v_off_ini = 450.158 uV, v_off_fin = 446.475 uV 17:47:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.948 uVs 17:47:44 Integrated Voltage Measurement... 17:47:53 Voltage Offset Correction: v_off_ini = 462.237 uV, v_off_fin = 455.245 uV 17:47:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.192 uVs 17:47:57 I1X Average and RMS of Measurements VT = -70.650 +- 7.504 uVs I1X = 14.130 +- 1.501 uTm 17:48:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:48:04 Integrated Voltage Measurement... 17:48:13 Voltage Offset Correction: v_off_ini = 445.127 uV, v_off_fin = 439.987 uV 17:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.766 uVs 17:48:13 Integrated Voltage Measurement... 17:48:22 Voltage Offset Correction: v_off_ini = 445.107 uV, v_off_fin = 458.652 uV 17:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.912 uVs 17:48:22 Integrated Voltage Measurement... 17:48:31 Voltage Offset Correction: v_off_ini = 447.364 uV, v_off_fin = 436.133 uV 17:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.247 uVs 17:48:31 Integrated Voltage Measurement... 17:48:40 Voltage Offset Correction: v_off_ini = 462.177 uV, v_off_fin = 465.866 uV 17:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.497 uVs 17:48:40 Integrated Voltage Measurement... 17:48:49 Voltage Offset Correction: v_off_ini = 450.192 uV, v_off_fin = 439.430 uV 17:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.667 uVs 17:48:49 Integrated Voltage Measurement... 17:48:58 Voltage Offset Correction: v_off_ini = 435.659 uV, v_off_fin = 461.526 uV 17:48:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.625 uVs 17:49:02 I1Y Average and RMS of Measurements VT = -213.452 +- 6.439 uVs I1Y = -42.688 +- 1.290 uTm 17:49:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:49:07 Integrated Voltage Measurement... 17:49:16 Voltage Offset Correction: v_off_ini = 438.917 uV, v_off_fin = 438.103 uV 17:49:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.128 uVs 17:49:16 Integrated Voltage Measurement... 17:49:25 Voltage Offset Correction: v_off_ini = 448.064 uV, v_off_fin = 456.989 uV 17:49:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.710 uVs 17:49:25 Integrated Voltage Measurement... 17:49:34 Voltage Offset Correction: v_off_ini = 457.474 uV, v_off_fin = 439.444 uV 17:49:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.209 uVs 17:49:34 Integrated Voltage Measurement... 17:49:43 Voltage Offset Correction: v_off_ini = 447.203 uV, v_off_fin = 457.593 uV 17:49:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.584 uVs 17:49:43 Integrated Voltage Measurement... 17:49:52 Voltage Offset Correction: v_off_ini = 454.176 uV, v_off_fin = 430.898 uV 17:49:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.567 uVs 17:49:52 Integrated Voltage Measurement... 17:50:01 Voltage Offset Correction: v_off_ini = 439.958 uV, v_off_fin = 455.359 uV 17:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.206 uVs 17:50:04 I2X Average and RMS of Measurements VT = -65.401 +- 11.108 uVs I2X = 6.017 +- 1.022 uTm^2 17:50:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:50:09 Integrated Voltage Measurement... 17:50:18 Voltage Offset Correction: v_off_ini = 453.864 uV, v_off_fin = 452.862 uV 17:50:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.459 uVs 17:50:18 Integrated Voltage Measurement... 17:50:27 Voltage Offset Correction: v_off_ini = 447.727 uV, v_off_fin = 436.012 uV 17:50:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.967 uVs 17:50:27 Integrated Voltage Measurement... 17:50:36 Voltage Offset Correction: v_off_ini = 441.717 uV, v_off_fin = 440.254 uV 17:50:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.970 uVs 17:50:36 Integrated Voltage Measurement... 17:50:45 Voltage Offset Correction: v_off_ini = 439.156 uV, v_off_fin = 442.291 uV 17:50:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.535 uVs 17:50:45 Integrated Voltage Measurement... 17:50:54 Voltage Offset Correction: v_off_ini = 453.480 uV, v_off_fin = 438.793 uV 17:50:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.475 uVs 17:50:54 Integrated Voltage Measurement... 17:51:03 Voltage Offset Correction: v_off_ini = 439.180 uV, v_off_fin = 451.357 uV 17:51:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.932 uVs 17:51:06 I2Y Average and RMS of Measurements VT = -223.723 +- 6.889 uVs I2Y = -20.583 +- 0.634 uTm^2 17:51:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:51:27 Integrated Voltage Measurement... 17:51:36 Voltage Offset Correction: v_off_ini = 465.888 uV, v_off_fin = 458.269 uV 17:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.518 uVs 17:51:36 Integrated Voltage Measurement... 17:51:45 Voltage Offset Correction: v_off_ini = 454.409 uV, v_off_fin = 464.548 uV 17:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.054 uVs 17:51:45 Integrated Voltage Measurement... 17:51:54 Voltage Offset Correction: v_off_ini = 456.832 uV, v_off_fin = 466.115 uV 17:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.659 uVs 17:51:54 Integrated Voltage Measurement... 17:52:03 Voltage Offset Correction: v_off_ini = 460.300 uV, v_off_fin = 464.982 uV 17:52:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.176 uVs 17:52:03 Integrated Voltage Measurement... 17:52:12 Voltage Offset Correction: v_off_ini = 462.390 uV, v_off_fin = 453.073 uV 17:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.117 uVs 17:52:12 Integrated Voltage Measurement... 17:52:21 Voltage Offset Correction: v_off_ini = 473.659 uV, v_off_fin = 460.526 uV 17:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.335 uVs 17:52:25 I1X Average and RMS of Measurements VT = -67.810 +- 2.786 uVs I1X = 13.562 +- 0.557 uTm 17:52:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:52:32 Integrated Voltage Measurement... 17:52:41 Voltage Offset Correction: v_off_ini = 462.324 uV, v_off_fin = 460.896 uV 17:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.817 uVs 17:52:41 Integrated Voltage Measurement... 17:52:50 Voltage Offset Correction: v_off_ini = 468.593 uV, v_off_fin = 476.731 uV 17:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.684 uVs 17:52:50 Integrated Voltage Measurement... 17:52:59 Voltage Offset Correction: v_off_ini = 455.838 uV, v_off_fin = 456.056 uV 17:52:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.499 uVs 17:52:59 Integrated Voltage Measurement... 17:53:08 Voltage Offset Correction: v_off_ini = 460.566 uV, v_off_fin = 466.062 uV 17:53:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.498 uVs 17:53:08 Integrated Voltage Measurement... 17:53:17 Voltage Offset Correction: v_off_ini = 459.879 uV, v_off_fin = 455.941 uV 17:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.334 uVs 17:53:17 Integrated Voltage Measurement... 17:53:26 Voltage Offset Correction: v_off_ini = 471.096 uV, v_off_fin = 471.576 uV 17:53:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.163 uVs 17:53:30 I1Y Average and RMS of Measurements VT = -211.999 +- 0.613 uVs I1Y = -42.400 +- 0.123 uTm 17:53:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:53:37 Integrated Voltage Measurement... 17:53:46 Voltage Offset Correction: v_off_ini = 457.671 uV, v_off_fin = 447.939 uV 17:53:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.002 uVs 17:53:46 Integrated Voltage Measurement... 17:53:55 Voltage Offset Correction: v_off_ini = 473.479 uV, v_off_fin = 479.750 uV 17:53:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.177 uVs 17:53:56 Integrated Voltage Measurement... 17:54:04 Voltage Offset Correction: v_off_ini = 464.924 uV, v_off_fin = 473.422 uV 17:54:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.815 uVs 17:54:05 Integrated Voltage Measurement... 17:54:13 Voltage Offset Correction: v_off_ini = 458.136 uV, v_off_fin = 476.662 uV 17:54:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.829 uVs 17:54:14 Integrated Voltage Measurement... 17:54:23 Voltage Offset Correction: v_off_ini = 460.437 uV, v_off_fin = 464.003 uV 17:54:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.636 uVs 17:54:23 Integrated Voltage Measurement... 17:54:32 Voltage Offset Correction: v_off_ini = 453.794 uV, v_off_fin = 454.909 uV 17:54:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.722 uVs 17:54:34 I2X Average and RMS of Measurements VT = -62.030 +- 5.346 uVs I2X = 5.707 +- 0.492 uTm^2 17:54:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:54:42 Integrated Voltage Measurement... 17:54:51 Voltage Offset Correction: v_off_ini = 467.567 uV, v_off_fin = 464.328 uV 17:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.015 uVs 17:54:51 Integrated Voltage Measurement... 17:55:00 Voltage Offset Correction: v_off_ini = 468.055 uV, v_off_fin = 470.631 uV 17:55:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.928 uVs 17:55:00 Integrated Voltage Measurement... 17:55:09 Voltage Offset Correction: v_off_ini = 478.121 uV, v_off_fin = 459.986 uV 17:55:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.108 uVs 17:55:09 Integrated Voltage Measurement... 17:55:18 Voltage Offset Correction: v_off_ini = 473.843 uV, v_off_fin = 464.394 uV 17:55:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.412 uVs 17:55:18 Integrated Voltage Measurement... 17:55:27 Voltage Offset Correction: v_off_ini = 453.401 uV, v_off_fin = 448.107 uV 17:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.197 uVs 17:55:27 Integrated Voltage Measurement... 17:55:36 Voltage Offset Correction: v_off_ini = 459.549 uV, v_off_fin = 459.663 uV 17:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.300 uVs 17:55:38 I2Y Average and RMS of Measurements VT = -208.827 +- 2.648 uVs I2Y = -19.212 +- 0.244 uTm^2 17:55:43 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:55:47 Integrated Voltage Measurement... 17:55:56 Voltage Offset Correction: v_off_ini = 467.725 uV, v_off_fin = 454.751 uV 17:55:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.918 uVs 17:55:56 Integrated Voltage Measurement... 17:56:05 Voltage Offset Correction: v_off_ini = 459.433 uV, v_off_fin = 453.402 uV 17:56:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.002 uVs 17:56:05 Integrated Voltage Measurement... 17:56:14 Voltage Offset Correction: v_off_ini = 461.665 uV, v_off_fin = 456.916 uV 17:56:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.013 uVs 17:56:14 Integrated Voltage Measurement... 17:56:23 Voltage Offset Correction: v_off_ini = 461.880 uV, v_off_fin = 455.436 uV 17:56:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.264 uVs 17:56:23 Integrated Voltage Measurement... 17:56:32 Voltage Offset Correction: v_off_ini = 457.249 uV, v_off_fin = 449.862 uV 17:56:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.070 uVs 17:56:32 Integrated Voltage Measurement... 17:56:41 Voltage Offset Correction: v_off_ini = 458.812 uV, v_off_fin = 456.996 uV 17:56:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.003 uVs 17:56:45 I1X Average and RMS of Measurements VT = -77.712 +- 6.477 uVs I1X = 15.543 +- 1.296 uTm 17:56:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:56:52 Integrated Voltage Measurement... 17:57:01 Voltage Offset Correction: v_off_ini = 463.766 uV, v_off_fin = 453.199 uV 17:57:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.774 uVs 17:57:01 Integrated Voltage Measurement... 17:57:10 Voltage Offset Correction: v_off_ini = 468.880 uV, v_off_fin = 478.744 uV 17:57:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.106 uVs 17:57:10 Integrated Voltage Measurement... 17:57:19 Voltage Offset Correction: v_off_ini = 460.995 uV, v_off_fin = 451.627 uV 17:57:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.547 uVs 17:57:19 Integrated Voltage Measurement... 17:57:28 Voltage Offset Correction: v_off_ini = 452.938 uV, v_off_fin = 463.978 uV 17:57:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.816 uVs 17:57:28 Integrated Voltage Measurement... 17:57:37 Voltage Offset Correction: v_off_ini = 462.374 uV, v_off_fin = 450.690 uV 17:57:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.671 uVs 17:57:37 Integrated Voltage Measurement... 17:57:46 Voltage Offset Correction: v_off_ini = 467.465 uV, v_off_fin = 479.904 uV 17:57:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.032 uVs 17:57:50 I1Y Average and RMS of Measurements VT = -203.491 +- 5.887 uVs I1Y = -40.698 +- 1.177 uTm 17:57:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:57:58 Integrated Voltage Measurement... 17:58:07 Voltage Offset Correction: v_off_ini = 462.830 uV, v_off_fin = 464.435 uV 17:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.310 uVs 17:58:07 Integrated Voltage Measurement... 17:58:16 Voltage Offset Correction: v_off_ini = 472.827 uV, v_off_fin = 479.906 uV 17:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.328 uVs 17:58:16 Integrated Voltage Measurement... 17:58:25 Voltage Offset Correction: v_off_ini = 471.406 uV, v_off_fin = 467.547 uV 17:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.979 uVs 17:58:25 Integrated Voltage Measurement... 17:58:34 Voltage Offset Correction: v_off_ini = 471.403 uV, v_off_fin = 476.723 uV 17:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.795 uVs 17:58:34 Integrated Voltage Measurement... 17:58:43 Voltage Offset Correction: v_off_ini = 469.541 uV, v_off_fin = 460.109 uV 17:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.542 uVs 17:58:43 Integrated Voltage Measurement... 17:58:52 Voltage Offset Correction: v_off_ini = 468.594 uV, v_off_fin = 466.168 uV 17:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.709 uVs 17:58:54 I2X Average and RMS of Measurements VT = -65.611 +- 4.071 uVs I2X = 6.036 +- 0.375 uTm^2 17:58:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:59:02 Integrated Voltage Measurement... 17:59:11 Voltage Offset Correction: v_off_ini = 467.616 uV, v_off_fin = 464.514 uV 17:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.895 uVs 17:59:11 Integrated Voltage Measurement... 17:59:20 Voltage Offset Correction: v_off_ini = 471.109 uV, v_off_fin = 468.548 uV 17:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.476 uVs 17:59:20 Integrated Voltage Measurement... 17:59:29 Voltage Offset Correction: v_off_ini = 468.292 uV, v_off_fin = 464.251 uV 17:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.429 uVs 17:59:29 Integrated Voltage Measurement... 17:59:38 Voltage Offset Correction: v_off_ini = 469.121 uV, v_off_fin = 464.292 uV 17:59:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.843 uVs 17:59:38 Integrated Voltage Measurement... 17:59:47 Voltage Offset Correction: v_off_ini = 476.947 uV, v_off_fin = 466.957 uV 17:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.100 uVs 17:59:47 Integrated Voltage Measurement... 17:59:56 Voltage Offset Correction: v_off_ini = 463.718 uV, v_off_fin = 464.682 uV 17:59:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.863 uVs 17:59:59 I2Y Average and RMS of Measurements VT = -213.101 +- 2.595 uVs I2Y = -19.605 +- 0.239 uTm^2 18:00:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:00:07 Integrated Voltage Measurement... 18:00:16 Voltage Offset Correction: v_off_ini = 462.204 uV, v_off_fin = 453.618 uV 18:00:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -64.918 uVs 18:00:16 Integrated Voltage Measurement... 18:00:25 Voltage Offset Correction: v_off_ini = 467.072 uV, v_off_fin = 476.790 uV 18:00:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.244 uVs 18:00:25 Integrated Voltage Measurement... 18:00:34 Voltage Offset Correction: v_off_ini = 462.057 uV, v_off_fin = 463.325 uV 18:00:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.541 uVs 18:00:34 Integrated Voltage Measurement... 18:00:43 Voltage Offset Correction: v_off_ini = 469.867 uV, v_off_fin = 468.234 uV 18:00:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.979 uVs 18:00:43 Integrated Voltage Measurement... 18:00:52 Voltage Offset Correction: v_off_ini = 459.657 uV, v_off_fin = 455.994 uV 18:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.330 uVs 18:00:52 Integrated Voltage Measurement... 18:01:01 Voltage Offset Correction: v_off_ini = 473.896 uV, v_off_fin = 470.931 uV 18:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.889 uVs 18:01:06 I1X Average and RMS of Measurements VT = -72.317 +- 5.741 uVs I1X = 14.464 +- 1.147 uTm 18:01:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:01:12 Integrated Voltage Measurement... 18:01:21 Voltage Offset Correction: v_off_ini = 470.439 uV, v_off_fin = 459.888 uV 18:01:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.583 uVs 18:01:21 Integrated Voltage Measurement... 18:01:30 Voltage Offset Correction: v_off_ini = 478.708 uV, v_off_fin = 494.447 uV 18:01:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.901 uVs 18:01:30 Integrated Voltage Measurement... 18:01:39 Voltage Offset Correction: v_off_ini = 480.350 uV, v_off_fin = 483.872 uV 18:01:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.525 uVs 18:01:39 Integrated Voltage Measurement... 18:01:48 Voltage Offset Correction: v_off_ini = 486.089 uV, v_off_fin = 503.270 uV 18:01:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.836 uVs 18:01:48 Integrated Voltage Measurement... 18:01:57 Voltage Offset Correction: v_off_ini = 494.358 uV, v_off_fin = 479.722 uV 18:01:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.831 uVs 18:01:57 Integrated Voltage Measurement... 18:02:06 Voltage Offset Correction: v_off_ini = 482.949 uV, v_off_fin = 497.696 uV 18:02:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.136 uVs 18:02:10 I1Y Average and RMS of Measurements VT = -206.469 +- 3.768 uVs I1Y = -41.294 +- 0.754 uTm 18:02:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:18 Integrated Voltage Measurement... 18:02:27 Voltage Offset Correction: v_off_ini = 466.406 uV, v_off_fin = 471.837 uV 18:02:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.969 uVs 18:02:27 Integrated Voltage Measurement... 18:02:36 Voltage Offset Correction: v_off_ini = 472.977 uV, v_off_fin = 484.809 uV 18:02:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.654 uVs 18:02:36 Integrated Voltage Measurement... 18:02:45 Voltage Offset Correction: v_off_ini = 478.519 uV, v_off_fin = 472.271 uV 18:02:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.175 uVs 18:02:45 Integrated Voltage Measurement... 18:02:54 Voltage Offset Correction: v_off_ini = 477.491 uV, v_off_fin = 489.887 uV 18:02:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.145 uVs 18:02:54 Integrated Voltage Measurement... 18:03:03 Voltage Offset Correction: v_off_ini = 476.183 uV, v_off_fin = 467.792 uV 18:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.547 uVs 18:03:03 Integrated Voltage Measurement... 18:03:12 Voltage Offset Correction: v_off_ini = 478.502 uV, v_off_fin = 486.304 uV 18:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.710 uVs 18:03:15 I2X Average and RMS of Measurements VT = -78.367 +- 2.925 uVs I2X = 7.210 +- 0.269 uTm^2 18:03:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:22 Integrated Voltage Measurement... 18:03:31 Voltage Offset Correction: v_off_ini = 478.712 uV, v_off_fin = 473.568 uV 18:03:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.937 uVs 18:03:31 Integrated Voltage Measurement... 18:03:40 Voltage Offset Correction: v_off_ini = 457.219 uV, v_off_fin = 459.777 uV 18:03:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.007 uVs 18:03:40 Integrated Voltage Measurement... 18:03:49 Voltage Offset Correction: v_off_ini = 467.446 uV, v_off_fin = 467.970 uV 18:03:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.110 uVs 18:03:50 Integrated Voltage Measurement... 18:03:58 Voltage Offset Correction: v_off_ini = 461.851 uV, v_off_fin = 466.429 uV 18:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.640 uVs 18:03:59 Integrated Voltage Measurement... 18:04:08 Voltage Offset Correction: v_off_ini = 465.125 uV, v_off_fin = 462.739 uV 18:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.917 uVs 18:04:08 Integrated Voltage Measurement... 18:04:17 Voltage Offset Correction: v_off_ini = 460.220 uV, v_off_fin = 452.904 uV 18:04:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.260 uVs 18:04:19 I2Y Average and RMS of Measurements VT = -214.812 +- 6.673 uVs I2Y = -19.763 +- 0.614 uTm^2 18:04:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:04:28 Integrated Voltage Measurement... 18:04:37 Voltage Offset Correction: v_off_ini = 460.139 uV, v_off_fin = 454.093 uV 18:04:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.160 uVs 18:04:37 Integrated Voltage Measurement... 18:04:46 Voltage Offset Correction: v_off_ini = 465.127 uV, v_off_fin = 458.965 uV 18:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.058 uVs 18:04:46 Integrated Voltage Measurement... 18:04:55 Voltage Offset Correction: v_off_ini = 456.765 uV, v_off_fin = 447.277 uV 18:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.639 uVs 18:04:55 Integrated Voltage Measurement... 18:05:04 Voltage Offset Correction: v_off_ini = 451.091 uV, v_off_fin = 461.041 uV 18:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.526 uVs 18:05:04 Integrated Voltage Measurement... 18:05:13 Voltage Offset Correction: v_off_ini = 456.053 uV, v_off_fin = 443.516 uV 18:05:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.777 uVs 18:05:13 Integrated Voltage Measurement... 18:05:22 Voltage Offset Correction: v_off_ini = 436.109 uV, v_off_fin = 450.487 uV 18:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.926 uVs 18:05:26 I1X Average and RMS of Measurements VT = -90.681 +- 7.348 uVs I1X = 18.137 +- 1.470 uTm 18:05:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:05:33 Integrated Voltage Measurement... 18:05:42 Voltage Offset Correction: v_off_ini = 451.934 uV, v_off_fin = 436.979 uV 18:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.613 uVs 18:05:42 Integrated Voltage Measurement... 18:05:51 Voltage Offset Correction: v_off_ini = 458.809 uV, v_off_fin = 454.457 uV 18:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.875 uVs 18:05:51 Integrated Voltage Measurement... 18:06:00 Voltage Offset Correction: v_off_ini = 450.584 uV, v_off_fin = 429.738 uV 18:06:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.105 uVs 18:06:00 Integrated Voltage Measurement... 18:06:09 Voltage Offset Correction: v_off_ini = 444.330 uV, v_off_fin = 457.544 uV 18:06:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.557 uVs 18:06:09 Integrated Voltage Measurement... 18:06:18 Voltage Offset Correction: v_off_ini = 441.146 uV, v_off_fin = 429.039 uV 18:06:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.751 uVs 18:06:18 Integrated Voltage Measurement... 18:06:27 Voltage Offset Correction: v_off_ini = 432.349 uV, v_off_fin = 449.426 uV 18:06:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.329 uVs 18:06:31 I1Y Average and RMS of Measurements VT = -199.872 +- 7.093 uVs I1Y = -39.974 +- 1.419 uTm 18:06:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:06:39 Integrated Voltage Measurement... 18:06:48 Voltage Offset Correction: v_off_ini = 442.947 uV, v_off_fin = 434.277 uV 18:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.669 uVs 18:06:48 Integrated Voltage Measurement... 18:06:57 Voltage Offset Correction: v_off_ini = 439.831 uV, v_off_fin = 442.892 uV 18:06:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.812 uVs 18:06:57 Integrated Voltage Measurement... 18:07:06 Voltage Offset Correction: v_off_ini = 440.943 uV, v_off_fin = 433.501 uV 18:07:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.330 uVs 18:07:06 Integrated Voltage Measurement... 18:07:15 Voltage Offset Correction: v_off_ini = 449.604 uV, v_off_fin = 456.445 uV 18:07:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.575 uVs 18:07:15 Integrated Voltage Measurement... 18:07:24 Voltage Offset Correction: v_off_ini = 445.799 uV, v_off_fin = 444.880 uV 18:07:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.353 uVs 18:07:24 Integrated Voltage Measurement... 18:07:33 Voltage Offset Correction: v_off_ini = 446.871 uV, v_off_fin = 454.248 uV 18:07:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.361 uVs 18:07:35 I2X Average and RMS of Measurements VT = -86.683 +- 6.398 uVs I2X = 7.975 +- 0.589 uTm^2 18:07:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:07:43 Integrated Voltage Measurement... 18:07:52 Voltage Offset Correction: v_off_ini = 439.461 uV, v_off_fin = 444.367 uV 18:07:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.959 uVs 18:07:52 Integrated Voltage Measurement... 18:08:01 Voltage Offset Correction: v_off_ini = 443.912 uV, v_off_fin = 441.895 uV 18:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.519 uVs 18:08:01 Integrated Voltage Measurement... 18:08:10 Voltage Offset Correction: v_off_ini = 438.175 uV, v_off_fin = 438.312 uV 18:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.680 uVs 18:08:10 Integrated Voltage Measurement... 18:08:19 Voltage Offset Correction: v_off_ini = 431.533 uV, v_off_fin = 435.500 uV 18:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.030 uVs 18:08:19 Integrated Voltage Measurement... 18:08:28 Voltage Offset Correction: v_off_ini = 436.830 uV, v_off_fin = 435.810 uV 18:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.822 uVs 18:08:28 Integrated Voltage Measurement... 18:08:37 Voltage Offset Correction: v_off_ini = 445.923 uV, v_off_fin = 435.168 uV 18:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.089 uVs 18:08:40 I2Y Average and RMS of Measurements VT = -193.516 +- 6.417 uVs I2Y = -17.804 +- 0.590 uTm^2 18:08:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:08:49 Integrated Voltage Measurement... 18:08:58 Voltage Offset Correction: v_off_ini = 439.504 uV, v_off_fin = 434.800 uV 18:08:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -86.401 uVs 18:08:58 Integrated Voltage Measurement... 18:09:07 Voltage Offset Correction: v_off_ini = 443.449 uV, v_off_fin = 442.854 uV 18:09:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.995 uVs 18:09:07 Integrated Voltage Measurement... 18:09:16 Voltage Offset Correction: v_off_ini = 442.988 uV, v_off_fin = 445.887 uV 18:09:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.007 uVs 18:09:16 Integrated Voltage Measurement... 18:09:25 Voltage Offset Correction: v_off_ini = 425.287 uV, v_off_fin = 433.952 uV 18:09:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.720 uVs 18:09:25 Integrated Voltage Measurement... 18:09:34 Voltage Offset Correction: v_off_ini = 425.257 uV, v_off_fin = 423.695 uV 18:09:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.147 uVs 18:09:34 Integrated Voltage Measurement... 18:09:43 Voltage Offset Correction: v_off_ini = 427.743 uV, v_off_fin = 437.178 uV 18:09:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.440 uVs 18:09:47 I1X Average and RMS of Measurements VT = -86.118 +- 5.115 uVs I1X = 17.225 +- 1.024 uTm 18:09:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:09:54 Integrated Voltage Measurement... 18:10:03 Voltage Offset Correction: v_off_ini = 422.220 uV, v_off_fin = 415.795 uV 18:10:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.689 uVs 18:10:03 Integrated Voltage Measurement... 18:10:12 Voltage Offset Correction: v_off_ini = 439.908 uV, v_off_fin = 444.764 uV 18:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.776 uVs 18:10:12 Integrated Voltage Measurement... 18:10:21 Voltage Offset Correction: v_off_ini = 435.760 uV, v_off_fin = 431.955 uV 18:10:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.746 uVs 18:10:21 Integrated Voltage Measurement... 18:10:30 Voltage Offset Correction: v_off_ini = 435.354 uV, v_off_fin = 442.139 uV 18:10:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.549 uVs 18:10:30 Integrated Voltage Measurement... 18:10:39 Voltage Offset Correction: v_off_ini = 454.143 uV, v_off_fin = 438.942 uV 18:10:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.553 uVs 18:10:39 Integrated Voltage Measurement... 18:10:48 Voltage Offset Correction: v_off_ini = 438.801 uV, v_off_fin = 458.889 uV 18:10:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.991 uVs 18:10:52 I1Y Average and RMS of Measurements VT = -199.551 +- 13.245 uVs I1Y = -39.910 +- 2.649 uTm 18:10:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:11:00 Integrated Voltage Measurement... 18:11:09 Voltage Offset Correction: v_off_ini = 444.266 uV, v_off_fin = 437.788 uV 18:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.938 uVs 18:11:09 Integrated Voltage Measurement... 18:11:18 Voltage Offset Correction: v_off_ini = 452.858 uV, v_off_fin = 446.640 uV 18:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.993 uVs 18:11:18 Integrated Voltage Measurement... 18:11:27 Voltage Offset Correction: v_off_ini = 437.807 uV, v_off_fin = 428.227 uV 18:11:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.513 uVs 18:11:27 Integrated Voltage Measurement... 18:11:36 Voltage Offset Correction: v_off_ini = 433.872 uV, v_off_fin = 450.611 uV 18:11:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.129 uVs 18:11:36 Integrated Voltage Measurement... 18:11:45 Voltage Offset Correction: v_off_ini = 448.770 uV, v_off_fin = 432.018 uV 18:11:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.460 uVs 18:11:45 Integrated Voltage Measurement... 18:11:54 Voltage Offset Correction: v_off_ini = 445.602 uV, v_off_fin = 446.949 uV 18:11:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.385 uVs 18:11:56 I2X Average and RMS of Measurements VT = -78.903 +- 6.547 uVs I2X = 7.259 +- 0.602 uTm^2 18:12:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:12:04 Integrated Voltage Measurement... 18:12:13 Voltage Offset Correction: v_off_ini = 440.347 uV, v_off_fin = 441.402 uV 18:12:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.444 uVs 18:12:13 Integrated Voltage Measurement... 18:12:22 Voltage Offset Correction: v_off_ini = 442.224 uV, v_off_fin = 428.303 uV 18:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.272 uVs 18:12:22 Integrated Voltage Measurement... 18:12:31 Voltage Offset Correction: v_off_ini = 434.593 uV, v_off_fin = 429.428 uV 18:12:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.913 uVs 18:12:31 Integrated Voltage Measurement... 18:12:40 Voltage Offset Correction: v_off_ini = 431.789 uV, v_off_fin = 441.010 uV 18:12:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.320 uVs 18:12:40 Integrated Voltage Measurement... 18:12:49 Voltage Offset Correction: v_off_ini = 441.341 uV, v_off_fin = 442.402 uV 18:12:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.750 uVs 18:12:49 Integrated Voltage Measurement... 18:12:58 Voltage Offset Correction: v_off_ini = 441.953 uV, v_off_fin = 432.171 uV 18:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.913 uVs 18:13:00 I2Y Average and RMS of Measurements VT = -200.102 +- 2.683 uVs I2Y = -18.409 +- 0.247 uTm^2 18:13:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:13:12 Integrated Voltage Measurement... 18:13:21 Voltage Offset Correction: v_off_ini = 439.048 uV, v_off_fin = 438.200 uV 18:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.826 uVs 18:13:21 Integrated Voltage Measurement... 18:13:30 Voltage Offset Correction: v_off_ini = 442.794 uV, v_off_fin = 452.581 uV 18:13:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.754 uVs 18:13:30 Integrated Voltage Measurement... 18:13:39 Voltage Offset Correction: v_off_ini = 463.800 uV, v_off_fin = 450.641 uV 18:13:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.408 uVs 18:13:39 Integrated Voltage Measurement... 18:13:48 Voltage Offset Correction: v_off_ini = 457.674 uV, v_off_fin = 461.155 uV 18:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.732 uVs 18:13:49 Integrated Voltage Measurement... 18:13:57 Voltage Offset Correction: v_off_ini = 455.985 uV, v_off_fin = 447.026 uV 18:13:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.290 uVs 18:13:58 Integrated Voltage Measurement... 18:14:07 Voltage Offset Correction: v_off_ini = 443.579 uV, v_off_fin = 447.143 uV 18:14:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.979 uVs 18:14:11 I1X Average and RMS of Measurements VT = -75.998 +- 5.831 uVs I1X = 15.200 +- 1.166 uTm 18:14:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:14:18 Integrated Voltage Measurement... 18:14:26 Voltage Offset Correction: v_off_ini = 451.673 uV, v_off_fin = 438.756 uV 18:14:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.814 uVs 18:14:27 Integrated Voltage Measurement... 18:14:35 Voltage Offset Correction: v_off_ini = 439.974 uV, v_off_fin = 440.094 uV 18:14:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.745 uVs 18:14:36 Integrated Voltage Measurement... 18:14:44 Voltage Offset Correction: v_off_ini = 432.418 uV, v_off_fin = 427.705 uV 18:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.461 uVs 18:14:45 Integrated Voltage Measurement... 18:14:53 Voltage Offset Correction: v_off_ini = 441.491 uV, v_off_fin = 443.523 uV 18:14:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.358 uVs 18:14:54 Integrated Voltage Measurement... 18:15:02 Voltage Offset Correction: v_off_ini = 429.820 uV, v_off_fin = 428.418 uV 18:15:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.402 uVs 18:15:03 Integrated Voltage Measurement... 18:15:11 Voltage Offset Correction: v_off_ini = 440.407 uV, v_off_fin = 443.457 uV 18:15:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.661 uVs 18:15:16 I1Y Average and RMS of Measurements VT = -202.240 +- 4.921 uVs I1Y = -40.448 +- 0.984 uTm 18:15:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:15:21 Integrated Voltage Measurement... 18:15:30 Voltage Offset Correction: v_off_ini = 433.030 uV, v_off_fin = 442.285 uV 18:15:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -68.873 uVs 18:15:30 Integrated Voltage Measurement... 18:15:39 Voltage Offset Correction: v_off_ini = 441.127 uV, v_off_fin = 447.869 uV 18:15:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.988 uVs 18:15:39 Integrated Voltage Measurement... 18:15:48 Voltage Offset Correction: v_off_ini = 452.042 uV, v_off_fin = 441.799 uV 18:15:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.852 uVs 18:15:48 Integrated Voltage Measurement... 18:15:57 Voltage Offset Correction: v_off_ini = 453.051 uV, v_off_fin = 464.846 uV 18:15:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.745 uVs 18:15:57 Integrated Voltage Measurement... 18:16:06 Voltage Offset Correction: v_off_ini = 466.853 uV, v_off_fin = 455.241 uV 18:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.641 uVs 18:16:06 Integrated Voltage Measurement... 18:16:15 Voltage Offset Correction: v_off_ini = 466.260 uV, v_off_fin = 463.682 uV 18:16:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.810 uVs 18:16:17 I2X Average and RMS of Measurements VT = -73.485 +- 2.199 uVs I2X = 6.761 +- 0.202 uTm^2 18:16:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:16:22 Integrated Voltage Measurement... 18:16:31 Voltage Offset Correction: v_off_ini = 477.861 uV, v_off_fin = 476.630 uV 18:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.944 uVs 18:16:32 Integrated Voltage Measurement... 18:16:40 Voltage Offset Correction: v_off_ini = 480.374 uV, v_off_fin = 481.466 uV 18:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.094 uVs 18:16:41 Integrated Voltage Measurement... 18:16:50 Voltage Offset Correction: v_off_ini = 475.957 uV, v_off_fin = 460.197 uV 18:16:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.151 uVs 18:16:50 Integrated Voltage Measurement... 18:16:59 Voltage Offset Correction: v_off_ini = 471.184 uV, v_off_fin = 478.999 uV 18:16:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.093 uVs 18:16:59 Integrated Voltage Measurement... 18:17:08 Voltage Offset Correction: v_off_ini = 480.055 uV, v_off_fin = 478.850 uV 18:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.491 uVs 18:17:08 Integrated Voltage Measurement... 18:17:17 Voltage Offset Correction: v_off_ini = 483.083 uV, v_off_fin = 478.830 uV 18:17:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.827 uVs 18:17:19 I2Y Average and RMS of Measurements VT = -198.267 +- 6.142 uVs I2Y = -18.241 +- 0.565 uTm^2 18:17:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:17:27 Integrated Voltage Measurement... 18:17:36 Voltage Offset Correction: v_off_ini = 487.046 uV, v_off_fin = 477.764 uV 18:17:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -87.145 uVs 18:17:36 Integrated Voltage Measurement... 18:17:45 Voltage Offset Correction: v_off_ini = 473.051 uV, v_off_fin = 479.517 uV 18:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.883 uVs 18:17:45 Integrated Voltage Measurement... 18:17:54 Voltage Offset Correction: v_off_ini = 480.473 uV, v_off_fin = 480.836 uV 18:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.016 uVs 18:17:54 Integrated Voltage Measurement... 18:18:03 Voltage Offset Correction: v_off_ini = 485.272 uV, v_off_fin = 483.576 uV 18:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.832 uVs 18:18:03 Integrated Voltage Measurement... 18:18:12 Voltage Offset Correction: v_off_ini = 478.591 uV, v_off_fin = 480.799 uV 18:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.316 uVs 18:18:12 Integrated Voltage Measurement... 18:18:21 Voltage Offset Correction: v_off_ini = 481.417 uV, v_off_fin = 478.960 uV 18:18:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.154 uVs 18:18:26 I1X Average and RMS of Measurements VT = -75.058 +- 0.749 uVs I1X = 15.012 +- 0.149 uTm 18:18:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:18:32 Integrated Voltage Measurement... 18:18:41 Voltage Offset Correction: v_off_ini = 476.359 uV, v_off_fin = 471.803 uV 18:18:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.897 uVs 18:18:41 Integrated Voltage Measurement... 18:18:50 Voltage Offset Correction: v_off_ini = 482.460 uV, v_off_fin = 484.191 uV 18:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.122 uVs 18:18:50 Integrated Voltage Measurement... 18:18:59 Voltage Offset Correction: v_off_ini = 481.198 uV, v_off_fin = 467.655 uV 18:18:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.053 uVs 18:18:59 Integrated Voltage Measurement... 18:19:08 Voltage Offset Correction: v_off_ini = 477.434 uV, v_off_fin = 486.386 uV 18:19:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.492 uVs 18:19:08 Integrated Voltage Measurement... 18:19:17 Voltage Offset Correction: v_off_ini = 466.953 uV, v_off_fin = 464.277 uV 18:19:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.786 uVs 18:19:17 Integrated Voltage Measurement... 18:19:26 Voltage Offset Correction: v_off_ini = 466.992 uV, v_off_fin = 479.682 uV 18:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.145 uVs 18:19:31 I1Y Average and RMS of Measurements VT = -204.083 +- 4.887 uVs I1Y = -40.817 +- 0.977 uTm 18:19:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:19:36 Integrated Voltage Measurement... 18:19:45 Voltage Offset Correction: v_off_ini = 464.625 uV, v_off_fin = 465.158 uV 18:19:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.745 uVs 18:19:45 Integrated Voltage Measurement... 18:19:54 Voltage Offset Correction: v_off_ini = 474.993 uV, v_off_fin = 480.482 uV 18:19:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.708 uVs 18:19:54 Integrated Voltage Measurement... 18:20:03 Voltage Offset Correction: v_off_ini = 467.718 uV, v_off_fin = 467.603 uV 18:20:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.118 uVs 18:20:03 Integrated Voltage Measurement... 18:20:12 Voltage Offset Correction: v_off_ini = 477.810 uV, v_off_fin = 474.570 uV 18:20:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.249 uVs 18:20:12 Integrated Voltage Measurement... 18:20:21 Voltage Offset Correction: v_off_ini = 462.180 uV, v_off_fin = 460.274 uV 18:20:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.380 uVs 18:20:21 Integrated Voltage Measurement... 18:20:30 Voltage Offset Correction: v_off_ini = 477.150 uV, v_off_fin = 477.998 uV 18:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.875 uVs 18:20:32 I2X Average and RMS of Measurements VT = -70.013 +- 7.105 uVs I2X = 6.441 +- 0.654 uTm^2 18:20:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:20:37 Integrated Voltage Measurement... 18:20:46 Voltage Offset Correction: v_off_ini = 470.331 uV, v_off_fin = 480.008 uV 18:20:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.706 uVs 18:20:46 Integrated Voltage Measurement... 18:20:55 Voltage Offset Correction: v_off_ini = 476.145 uV, v_off_fin = 480.921 uV 18:20:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.227 uVs 18:20:56 Integrated Voltage Measurement... 18:21:05 Voltage Offset Correction: v_off_ini = 470.982 uV, v_off_fin = 484.498 uV 18:21:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.002 uVs 18:21:05 Integrated Voltage Measurement... 18:21:14 Voltage Offset Correction: v_off_ini = 463.631 uV, v_off_fin = 464.565 uV 18:21:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.670 uVs 18:21:14 Integrated Voltage Measurement... 18:21:23 Voltage Offset Correction: v_off_ini = 472.341 uV, v_off_fin = 476.761 uV 18:21:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.795 uVs 18:21:23 Integrated Voltage Measurement... 18:21:32 Voltage Offset Correction: v_off_ini = 478.464 uV, v_off_fin = 476.885 uV 18:21:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.375 uVs 18:21:34 I2Y Average and RMS of Measurements VT = -200.462 +- 1.770 uVs I2Y = -18.443 +- 0.163 uTm^2 18:21:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:21:42 Integrated Voltage Measurement... 18:21:51 Voltage Offset Correction: v_off_ini = 471.166 uV, v_off_fin = 474.205 uV 18:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -86.919 uVs 18:21:51 Integrated Voltage Measurement... 18:22:00 Voltage Offset Correction: v_off_ini = 468.295 uV, v_off_fin = 478.156 uV 18:22:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.422 uVs 18:22:00 Integrated Voltage Measurement... 18:22:09 Voltage Offset Correction: v_off_ini = 474.298 uV, v_off_fin = 475.914 uV 18:22:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.637 uVs 18:22:09 Integrated Voltage Measurement... 18:22:18 Voltage Offset Correction: v_off_ini = 471.376 uV, v_off_fin = 478.078 uV 18:22:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.577 uVs 18:22:18 Integrated Voltage Measurement... 18:22:27 Voltage Offset Correction: v_off_ini = 479.619 uV, v_off_fin = 462.420 uV 18:22:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.892 uVs 18:22:27 Integrated Voltage Measurement... 18:22:36 Voltage Offset Correction: v_off_ini = 471.815 uV, v_off_fin = 475.097 uV 18:22:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.525 uVs 18:22:41 I1X Average and RMS of Measurements VT = -82.495 +- 0.816 uVs I1X = 16.500 +- 0.163 uTm 18:22:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:22:47 Integrated Voltage Measurement... 18:22:56 Voltage Offset Correction: v_off_ini = 458.299 uV, v_off_fin = 456.494 uV 18:22:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.557 uVs 18:22:56 Integrated Voltage Measurement... 18:23:05 Voltage Offset Correction: v_off_ini = 488.516 uV, v_off_fin = 475.957 uV 18:23:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.708 uVs 18:23:05 Integrated Voltage Measurement... 18:23:14 Voltage Offset Correction: v_off_ini = 476.319 uV, v_off_fin = 462.624 uV 18:23:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.594 uVs 18:23:14 Integrated Voltage Measurement... 18:23:23 Voltage Offset Correction: v_off_ini = 467.187 uV, v_off_fin = 492.721 uV 18:23:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.944 uVs 18:23:23 Integrated Voltage Measurement... 18:23:32 Voltage Offset Correction: v_off_ini = 476.017 uV, v_off_fin = 462.612 uV 18:23:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.849 uVs 18:23:32 Integrated Voltage Measurement... 18:23:41 Voltage Offset Correction: v_off_ini = 482.873 uV, v_off_fin = 484.432 uV 18:23:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.528 uVs 18:23:46 I1Y Average and RMS of Measurements VT = -200.363 +- 3.433 uVs I1Y = -40.073 +- 0.687 uTm 18:23:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:23:51 Integrated Voltage Measurement... 18:24:00 Voltage Offset Correction: v_off_ini = 473.819 uV, v_off_fin = 468.854 uV 18:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.434 uVs 18:24:00 Integrated Voltage Measurement... 18:24:09 Voltage Offset Correction: v_off_ini = 479.284 uV, v_off_fin = 486.124 uV 18:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.021 uVs 18:24:09 Integrated Voltage Measurement... 18:24:18 Voltage Offset Correction: v_off_ini = 476.021 uV, v_off_fin = 476.200 uV 18:24:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.988 uVs 18:24:18 Integrated Voltage Measurement... 18:24:27 Voltage Offset Correction: v_off_ini = 476.602 uV, v_off_fin = 486.427 uV 18:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.153 uVs 18:24:27 Integrated Voltage Measurement... 18:24:36 Voltage Offset Correction: v_off_ini = 475.577 uV, v_off_fin = 473.354 uV 18:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.910 uVs 18:24:36 Integrated Voltage Measurement... 18:24:45 Voltage Offset Correction: v_off_ini = 479.467 uV, v_off_fin = 483.977 uV 18:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.048 uVs 18:24:47 I2X Average and RMS of Measurements VT = -77.592 +- 7.661 uVs I2X = 7.138 +- 0.705 uTm^2 18:24:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:24:52 Integrated Voltage Measurement... 18:25:01 Voltage Offset Correction: v_off_ini = 481.803 uV, v_off_fin = 495.072 uV 18:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.593 uVs 18:25:02 Integrated Voltage Measurement... 18:25:10 Voltage Offset Correction: v_off_ini = 480.395 uV, v_off_fin = 490.964 uV 18:25:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.370 uVs 18:25:11 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 487.875 uV, v_off_fin = 485.575 uV 18:25:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.635 uVs 18:25:20 Integrated Voltage Measurement... 18:25:29 Voltage Offset Correction: v_off_ini = 497.039 uV, v_off_fin = 494.890 uV 18:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.405 uVs 18:25:29 Integrated Voltage Measurement... 18:25:38 Voltage Offset Correction: v_off_ini = 482.537 uV, v_off_fin = 474.041 uV 18:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.490 uVs 18:25:38 Integrated Voltage Measurement... 18:25:47 Voltage Offset Correction: v_off_ini = 476.501 uV, v_off_fin = 482.476 uV 18:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.080 uVs 18:25:49 I2Y Average and RMS of Measurements VT = -207.429 +- 7.237 uVs I2Y = -19.083 +- 0.666 uTm^2 18:25:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:25:57 Integrated Voltage Measurement... 18:26:06 Voltage Offset Correction: v_off_ini = 486.521 uV, v_off_fin = 487.329 uV 18:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.701 uVs 18:26:06 Integrated Voltage Measurement... 18:26:15 Voltage Offset Correction: v_off_ini = 473.989 uV, v_off_fin = 478.985 uV 18:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.867 uVs 18:26:15 Integrated Voltage Measurement... 18:26:24 Voltage Offset Correction: v_off_ini = 471.653 uV, v_off_fin = 477.205 uV 18:26:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.523 uVs 18:26:24 Integrated Voltage Measurement... 18:26:33 Voltage Offset Correction: v_off_ini = 472.069 uV, v_off_fin = 467.857 uV 18:26:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.061 uVs 18:26:33 Integrated Voltage Measurement... 18:26:42 Voltage Offset Correction: v_off_ini = 468.081 uV, v_off_fin = 484.186 uV 18:26:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.866 uVs 18:26:42 Integrated Voltage Measurement... 18:26:51 Voltage Offset Correction: v_off_ini = 470.409 uV, v_off_fin = 476.945 uV 18:26:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.942 uVs 18:26:56 I1X Average and RMS of Measurements VT = -85.827 +- 4.695 uVs I1X = 17.166 +- 0.939 uTm 18:26:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:27:02 Integrated Voltage Measurement... 18:27:11 Voltage Offset Correction: v_off_ini = 473.981 uV, v_off_fin = 467.506 uV 18:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.553 uVs 18:27:11 Integrated Voltage Measurement... 18:27:20 Voltage Offset Correction: v_off_ini = 476.379 uV, v_off_fin = 486.124 uV 18:27:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.667 uVs 18:27:20 Integrated Voltage Measurement... 18:27:29 Voltage Offset Correction: v_off_ini = 485.869 uV, v_off_fin = 469.067 uV 18:27:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.654 uVs 18:27:29 Integrated Voltage Measurement... 18:27:38 Voltage Offset Correction: v_off_ini = 469.077 uV, v_off_fin = 494.589 uV 18:27:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.333 uVs 18:27:38 Integrated Voltage Measurement... 18:27:47 Voltage Offset Correction: v_off_ini = 497.375 uV, v_off_fin = 478.036 uV 18:27:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.336 uVs 18:27:47 Integrated Voltage Measurement... 18:27:56 Voltage Offset Correction: v_off_ini = 484.385 uV, v_off_fin = 482.281 uV 18:27:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.267 uVs 18:28:01 I1Y Average and RMS of Measurements VT = -209.302 +- 2.013 uVs I1Y = -41.859 +- 0.404 uTm 18:28:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:28:06 Integrated Voltage Measurement... 18:28:15 Voltage Offset Correction: v_off_ini = 473.487 uV, v_off_fin = 458.468 uV 18:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.908 uVs 18:28:15 Integrated Voltage Measurement... 18:28:24 Voltage Offset Correction: v_off_ini = 472.914 uV, v_off_fin = 479.021 uV 18:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.984 uVs 18:28:24 Integrated Voltage Measurement... 18:28:33 Voltage Offset Correction: v_off_ini = 463.532 uV, v_off_fin = 469.938 uV 18:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.294 uVs 18:28:33 Integrated Voltage Measurement... 18:28:42 Voltage Offset Correction: v_off_ini = 486.922 uV, v_off_fin = 492.355 uV 18:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.497 uVs 18:28:42 Integrated Voltage Measurement... 18:28:51 Voltage Offset Correction: v_off_ini = 482.769 uV, v_off_fin = 470.381 uV 18:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.062 uVs 18:28:51 Integrated Voltage Measurement... 18:29:00 Voltage Offset Correction: v_off_ini = 480.595 uV, v_off_fin = 486.172 uV 18:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.503 uVs 18:29:02 I2X Average and RMS of Measurements VT = -74.875 +- 1.566 uVs I2X = 6.888 +- 0.144 uTm^2 18:29:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:29:07 Integrated Voltage Measurement... 18:29:16 Voltage Offset Correction: v_off_ini = 482.709 uV, v_off_fin = 472.240 uV 18:29:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.812 uVs 18:29:16 Integrated Voltage Measurement... 18:29:25 Voltage Offset Correction: v_off_ini = 482.021 uV, v_off_fin = 491.491 uV 18:29:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.789 uVs 18:29:26 Integrated Voltage Measurement... 18:29:34 Voltage Offset Correction: v_off_ini = 485.967 uV, v_off_fin = 487.264 uV 18:29:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.818 uVs 18:29:35 Integrated Voltage Measurement... 18:29:44 Voltage Offset Correction: v_off_ini = 493.669 uV, v_off_fin = 490.181 uV 18:29:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.177 uVs 18:29:44 Integrated Voltage Measurement... 18:29:53 Voltage Offset Correction: v_off_ini = 476.186 uV, v_off_fin = 488.837 uV 18:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.961 uVs 18:29:53 Integrated Voltage Measurement... 18:30:02 Voltage Offset Correction: v_off_ini = 487.393 uV, v_off_fin = 491.642 uV 18:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.194 uVs 18:30:04 I2Y Average and RMS of Measurements VT = -206.459 +- 1.864 uVs I2Y = -18.994 +- 0.171 uTm^2 18:30:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:30:12 Integrated Voltage Measurement... 18:30:21 Voltage Offset Correction: v_off_ini = 499.407 uV, v_off_fin = 500.106 uV 18:30:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.431 uVs 18:30:21 Integrated Voltage Measurement... 18:30:30 Voltage Offset Correction: v_off_ini = 485.261 uV, v_off_fin = 490.345 uV 18:30:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.345 uVs 18:30:30 Integrated Voltage Measurement... 18:30:39 Voltage Offset Correction: v_off_ini = 494.487 uV, v_off_fin = 495.232 uV 18:30:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.053 uVs 18:30:39 Integrated Voltage Measurement... 18:30:48 Voltage Offset Correction: v_off_ini = 487.516 uV, v_off_fin = 491.930 uV 18:30:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.970 uVs 18:30:48 Integrated Voltage Measurement... 18:30:57 Voltage Offset Correction: v_off_ini = 483.802 uV, v_off_fin = 476.984 uV 18:30:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.435 uVs 18:30:57 Integrated Voltage Measurement... 18:31:06 Voltage Offset Correction: v_off_ini = 480.678 uV, v_off_fin = 483.062 uV 18:31:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.843 uVs 18:31:11 I1X Average and RMS of Measurements VT = -80.180 +- 1.628 uVs I1X = 16.036 +- 0.326 uTm 18:31:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:31:17 Integrated Voltage Measurement... 18:31:26 Voltage Offset Correction: v_off_ini = 484.555 uV, v_off_fin = 464.855 uV 18:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.811 uVs 18:31:26 Integrated Voltage Measurement... 18:31:35 Voltage Offset Correction: v_off_ini = 474.221 uV, v_off_fin = 485.325 uV 18:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.742 uVs 18:31:35 Integrated Voltage Measurement... 18:31:44 Voltage Offset Correction: v_off_ini = 476.319 uV, v_off_fin = 465.395 uV 18:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.208 uVs 18:31:44 Integrated Voltage Measurement... 18:31:53 Voltage Offset Correction: v_off_ini = 474.109 uV, v_off_fin = 493.640 uV 18:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.045 uVs 18:31:53 Integrated Voltage Measurement... 18:32:02 Voltage Offset Correction: v_off_ini = 471.994 uV, v_off_fin = 460.446 uV 18:32:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.293 uVs 18:32:02 Integrated Voltage Measurement... 18:32:11 Voltage Offset Correction: v_off_ini = 457.432 uV, v_off_fin = 484.739 uV 18:32:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.714 uVs 18:32:16 I1Y Average and RMS of Measurements VT = -208.969 +- 5.379 uVs I1Y = -41.791 +- 1.077 uTm 18:32:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:32:21 Integrated Voltage Measurement... 18:32:30 Voltage Offset Correction: v_off_ini = 458.147 uV, v_off_fin = 456.315 uV 18:32:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.847 uVs 18:32:30 Integrated Voltage Measurement... 18:32:39 Voltage Offset Correction: v_off_ini = 464.463 uV, v_off_fin = 470.862 uV 18:32:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.751 uVs 18:32:39 Integrated Voltage Measurement... 18:32:48 Voltage Offset Correction: v_off_ini = 467.725 uV, v_off_fin = 461.273 uV 18:32:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.008 uVs 18:32:48 Integrated Voltage Measurement... 18:32:57 Voltage Offset Correction: v_off_ini = 462.203 uV, v_off_fin = 480.311 uV 18:32:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.246 uVs 18:32:57 Integrated Voltage Measurement... 18:33:06 Voltage Offset Correction: v_off_ini = 479.506 uV, v_off_fin = 476.260 uV 18:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.893 uVs 18:33:06 Integrated Voltage Measurement... 18:33:15 Voltage Offset Correction: v_off_ini = 478.983 uV, v_off_fin = 487.770 uV 18:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.148 uVs 18:33:17 I2X Average and RMS of Measurements VT = -68.316 +- 10.999 uVs I2X = 6.285 +- 1.012 uTm^2 18:33:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:33:22 Integrated Voltage Measurement... 18:33:31 Voltage Offset Correction: v_off_ini = 475.537 uV, v_off_fin = 489.046 uV 18:33:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.064 uVs 18:33:32 Integrated Voltage Measurement... 18:33:40 Voltage Offset Correction: v_off_ini = 495.368 uV, v_off_fin = 499.177 uV 18:33:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.998 uVs 18:33:41 Integrated Voltage Measurement... 18:33:50 Voltage Offset Correction: v_off_ini = 499.660 uV, v_off_fin = 496.960 uV 18:33:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.586 uVs 18:33:50 Integrated Voltage Measurement... 18:33:59 Voltage Offset Correction: v_off_ini = 508.572 uV, v_off_fin = 505.562 uV 18:33:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.049 uVs 18:33:59 Integrated Voltage Measurement... 18:34:08 Voltage Offset Correction: v_off_ini = 489.758 uV, v_off_fin = 502.551 uV 18:34:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.868 uVs 18:34:08 Integrated Voltage Measurement... 18:34:17 Voltage Offset Correction: v_off_ini = 512.691 uV, v_off_fin = 497.899 uV 18:34:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.676 uVs 18:34:19 I2Y Average and RMS of Measurements VT = -205.540 +- 2.337 uVs I2Y = -18.910 +- 0.215 uTm^2 18:34:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:34:40 Integrated Voltage Measurement... 18:34:49 Voltage Offset Correction: v_off_ini = 496.215 uV, v_off_fin = 504.881 uV 18:34:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.338 uVs 18:34:49 Integrated Voltage Measurement... 18:34:58 Voltage Offset Correction: v_off_ini = 499.648 uV, v_off_fin = 507.721 uV 18:34:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.602 uVs 18:34:58 Integrated Voltage Measurement... 18:35:07 Voltage Offset Correction: v_off_ini = 509.764 uV, v_off_fin = 511.162 uV 18:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.752 uVs 18:35:07 Integrated Voltage Measurement... 18:35:16 Voltage Offset Correction: v_off_ini = 510.757 uV, v_off_fin = 505.019 uV 18:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.198 uVs 18:35:16 Integrated Voltage Measurement... 18:35:25 Voltage Offset Correction: v_off_ini = 505.849 uV, v_off_fin = 500.355 uV 18:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.275 uVs 18:35:25 Integrated Voltage Measurement... 18:35:34 Voltage Offset Correction: v_off_ini = 510.503 uV, v_off_fin = 501.939 uV 18:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.266 uVs 18:35:39 I1X Average and RMS of Measurements VT = -86.738 +- 11.030 uVs I1X = 17.348 +- 2.206 uTm 18:35:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:35:45 Integrated Voltage Measurement... 18:35:54 Voltage Offset Correction: v_off_ini = 476.743 uV, v_off_fin = 483.890 uV 18:35:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -195.740 uVs 18:35:54 Integrated Voltage Measurement... 18:36:03 Voltage Offset Correction: v_off_ini = 497.643 uV, v_off_fin = 498.242 uV 18:36:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.238 uVs 18:36:03 Integrated Voltage Measurement... 18:36:12 Voltage Offset Correction: v_off_ini = 488.044 uV, v_off_fin = 486.009 uV 18:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.811 uVs 18:36:12 Integrated Voltage Measurement... 18:36:21 Voltage Offset Correction: v_off_ini = 500.077 uV, v_off_fin = 505.008 uV 18:36:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.521 uVs 18:36:21 Integrated Voltage Measurement... 18:36:30 Voltage Offset Correction: v_off_ini = 490.411 uV, v_off_fin = 487.386 uV 18:36:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.383 uVs 18:36:30 Integrated Voltage Measurement... 18:36:39 Voltage Offset Correction: v_off_ini = 496.375 uV, v_off_fin = 509.177 uV 18:36:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.089 uVs 18:36:44 I1Y Average and RMS of Measurements VT = -195.797 +- 1.911 uVs I1Y = -39.160 +- 0.383 uTm 18:36:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:36:51 Integrated Voltage Measurement... 18:37:00 Voltage Offset Correction: v_off_ini = 489.311 uV, v_off_fin = 487.039 uV 18:37:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -63.309 uVs 18:37:00 Integrated Voltage Measurement... 18:37:09 Voltage Offset Correction: v_off_ini = 494.717 uV, v_off_fin = 489.911 uV 18:37:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.049 uVs 18:37:09 Integrated Voltage Measurement... 18:37:18 Voltage Offset Correction: v_off_ini = 487.907 uV, v_off_fin = 473.436 uV 18:37:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.447 uVs 18:37:18 Integrated Voltage Measurement... 18:37:27 Voltage Offset Correction: v_off_ini = 481.749 uV, v_off_fin = 488.108 uV 18:37:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.039 uVs 18:37:28 Integrated Voltage Measurement... 18:37:36 Voltage Offset Correction: v_off_ini = 487.149 uV, v_off_fin = 476.444 uV 18:37:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.961 uVs 18:37:37 Integrated Voltage Measurement... 18:37:46 Voltage Offset Correction: v_off_ini = 488.018 uV, v_off_fin = 491.143 uV 18:37:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.132 uVs 18:37:48 I2X Average and RMS of Measurements VT = -78.823 +- 5.259 uVs I2X = 7.252 +- 0.484 uTm^2 18:37:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:37:56 Integrated Voltage Measurement... 18:38:05 Voltage Offset Correction: v_off_ini = 487.175 uV, v_off_fin = 486.267 uV 18:38:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.097 uVs 18:38:05 Integrated Voltage Measurement... 18:38:14 Voltage Offset Correction: v_off_ini = 486.434 uV, v_off_fin = 482.874 uV 18:38:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 201.114 uVs 18:38:14 Integrated Voltage Measurement... 18:38:23 Voltage Offset Correction: v_off_ini = 470.464 uV, v_off_fin = 484.138 uV 18:38:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -171.074 uVs 18:38:23 Integrated Voltage Measurement... 18:38:32 Voltage Offset Correction: v_off_ini = 491.110 uV, v_off_fin = 477.386 uV 18:38:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.594 uVs 18:38:32 Integrated Voltage Measurement... 18:38:41 Voltage Offset Correction: v_off_ini = 475.958 uV, v_off_fin = 472.885 uV 18:38:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.731 uVs 18:38:41 Integrated Voltage Measurement... 18:38:50 Voltage Offset Correction: v_off_ini = 478.374 uV, v_off_fin = 488.496 uV 18:38:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.997 uVs 18:38:52 I2Y Average and RMS of Measurements VT = -197.101 +- 4.517 uVs I2Y = -18.134 +- 0.415 uTm^2 18:38:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:39:01 Integrated Voltage Measurement... 18:39:10 Voltage Offset Correction: v_off_ini = 474.270 uV, v_off_fin = 464.573 uV 18:39:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.007 uVs 18:39:10 Integrated Voltage Measurement... 18:39:19 Voltage Offset Correction: v_off_ini = 467.625 uV, v_off_fin = 462.806 uV 18:39:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.802 uVs 18:39:19 Integrated Voltage Measurement... 18:39:28 Voltage Offset Correction: v_off_ini = 461.220 uV, v_off_fin = 460.827 uV 18:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.212 uVs 18:39:28 Integrated Voltage Measurement... 18:39:37 Voltage Offset Correction: v_off_ini = 456.196 uV, v_off_fin = 457.714 uV 18:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.421 uVs 18:39:37 Integrated Voltage Measurement... 18:39:46 Voltage Offset Correction: v_off_ini = 459.990 uV, v_off_fin = 463.976 uV 18:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.261 uVs 18:39:46 Integrated Voltage Measurement... 18:39:55 Voltage Offset Correction: v_off_ini = 462.634 uV, v_off_fin = 463.325 uV 18:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.143 uVs 18:39:59 I1X Average and RMS of Measurements VT = -86.474 +- 4.246 uVs I1X = 17.296 +- 0.848 uTm 18:40:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:40:06 Integrated Voltage Measurement... 18:40:15 Voltage Offset Correction: v_off_ini = 461.126 uV, v_off_fin = 453.769 uV 18:40:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.735 uVs 18:40:15 Integrated Voltage Measurement... 18:40:24 Voltage Offset Correction: v_off_ini = 475.851 uV, v_off_fin = 476.909 uV 18:40:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.536 uVs 18:40:24 Integrated Voltage Measurement... 18:40:33 Voltage Offset Correction: v_off_ini = 478.120 uV, v_off_fin = 459.214 uV 18:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.657 uVs 18:40:33 Integrated Voltage Measurement... 18:40:42 Voltage Offset Correction: v_off_ini = 465.365 uV, v_off_fin = 468.760 uV 18:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.016 uVs 18:40:42 Integrated Voltage Measurement... 18:40:51 Voltage Offset Correction: v_off_ini = 470.128 uV, v_off_fin = 464.442 uV 18:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.151 uVs 18:40:51 Integrated Voltage Measurement... 18:41:00 Voltage Offset Correction: v_off_ini = 465.248 uV, v_off_fin = 482.872 uV 18:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.580 uVs 18:41:04 I1Y Average and RMS of Measurements VT = -195.612 +- 3.668 uVs I1Y = -39.122 +- 0.734 uTm 18:41:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:41:12 Integrated Voltage Measurement... 18:41:21 Voltage Offset Correction: v_off_ini = 468.991 uV, v_off_fin = 467.471 uV 18:41:21 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.794 uVs 18:41:21 Integrated Voltage Measurement... 18:41:30 Voltage Offset Correction: v_off_ini = 481.701 uV, v_off_fin = 463.484 uV 18:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.411 uVs 18:41:30 Integrated Voltage Measurement... 18:41:39 Voltage Offset Correction: v_off_ini = 471.191 uV, v_off_fin = 455.483 uV 18:41:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.492 uVs 18:41:39 Integrated Voltage Measurement... 18:41:48 Voltage Offset Correction: v_off_ini = 476.817 uV, v_off_fin = 480.475 uV 18:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.583 uVs 18:41:48 Integrated Voltage Measurement... 18:41:57 Voltage Offset Correction: v_off_ini = 464.597 uV, v_off_fin = 456.275 uV 18:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.076 uVs 18:41:57 Integrated Voltage Measurement... 18:42:06 Voltage Offset Correction: v_off_ini = 463.148 uV, v_off_fin = 470.538 uV 18:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.338 uVs 18:42:09 I2X Average and RMS of Measurements VT = -75.616 +- 6.080 uVs I2X = 6.957 +- 0.559 uTm^2 18:42:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:42:16 Integrated Voltage Measurement... 18:42:25 Voltage Offset Correction: v_off_ini = 457.125 uV, v_off_fin = 463.677 uV 18:42:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.734 uVs 18:42:25 Integrated Voltage Measurement... 18:42:34 Voltage Offset Correction: v_off_ini = 471.169 uV, v_off_fin = 470.627 uV 18:42:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.687 uVs 18:42:34 Integrated Voltage Measurement... 18:42:43 Voltage Offset Correction: v_off_ini = 471.740 uV, v_off_fin = 471.648 uV 18:42:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.290 uVs 18:42:43 Integrated Voltage Measurement... 18:42:52 Voltage Offset Correction: v_off_ini = 469.787 uV, v_off_fin = 466.986 uV 18:42:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.953 uVs 18:42:53 Integrated Voltage Measurement... 18:43:01 Voltage Offset Correction: v_off_ini = 463.737 uV, v_off_fin = 465.683 uV 18:43:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.537 uVs 18:43:02 Integrated Voltage Measurement... 18:43:11 Voltage Offset Correction: v_off_ini = 449.762 uV, v_off_fin = 470.004 uV 18:43:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.085 uVs 18:43:13 I2Y Average and RMS of Measurements VT = -196.048 +- 9.143 uVs I2Y = -18.036 +- 0.841 uTm^2 18:43:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:43:22 Integrated Voltage Measurement... 18:43:31 Voltage Offset Correction: v_off_ini = 469.059 uV, v_off_fin = 461.880 uV 18:43:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.535 uVs 18:43:31 Integrated Voltage Measurement... 18:43:40 Voltage Offset Correction: v_off_ini = 450.685 uV, v_off_fin = 461.358 uV 18:43:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.918 uVs 18:43:40 Integrated Voltage Measurement... 18:43:49 Voltage Offset Correction: v_off_ini = 468.854 uV, v_off_fin = 467.685 uV 18:43:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.214 uVs 18:43:49 Integrated Voltage Measurement... 18:43:58 Voltage Offset Correction: v_off_ini = 472.724 uV, v_off_fin = 469.715 uV 18:43:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.831 uVs 18:43:58 Integrated Voltage Measurement... 18:44:07 Voltage Offset Correction: v_off_ini = 476.914 uV, v_off_fin = 463.378 uV 18:44:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.756 uVs 18:44:07 Integrated Voltage Measurement... 18:44:16 Voltage Offset Correction: v_off_ini = 455.215 uV, v_off_fin = 465.790 uV 18:44:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.301 uVs 18:44:20 I1X Average and RMS of Measurements VT = -90.759 +- 3.820 uVs I1X = 18.152 +- 0.764 uTm 18:44:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:44:27 Integrated Voltage Measurement... 18:44:36 Voltage Offset Correction: v_off_ini = 458.323 uV, v_off_fin = 455.655 uV 18:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.552 uVs 18:44:36 Integrated Voltage Measurement... 18:44:45 Voltage Offset Correction: v_off_ini = 466.635 uV, v_off_fin = 468.053 uV 18:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.128 uVs 18:44:45 Integrated Voltage Measurement... 18:44:54 Voltage Offset Correction: v_off_ini = 461.198 uV, v_off_fin = 456.313 uV 18:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.002 uVs 18:44:54 Integrated Voltage Measurement... 18:45:03 Voltage Offset Correction: v_off_ini = 476.321 uV, v_off_fin = 482.535 uV 18:45:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.628 uVs 18:45:03 Integrated Voltage Measurement... 18:45:12 Voltage Offset Correction: v_off_ini = 469.125 uV, v_off_fin = 463.058 uV 18:45:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.411 uVs 18:45:12 Integrated Voltage Measurement... 18:45:21 Voltage Offset Correction: v_off_ini = 469.610 uV, v_off_fin = 479.225 uV 18:45:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.181 uVs 18:45:25 I1Y Average and RMS of Measurements VT = -204.650 +- 6.983 uVs I1Y = -40.930 +- 1.397 uTm 18:45:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:45:33 Integrated Voltage Measurement... 18:45:42 Voltage Offset Correction: v_off_ini = 479.206 uV, v_off_fin = 471.027 uV 18:45:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.366 uVs 18:45:42 Integrated Voltage Measurement... 18:45:51 Voltage Offset Correction: v_off_ini = 481.528 uV, v_off_fin = 492.718 uV 18:45:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.843 uVs 18:45:51 Integrated Voltage Measurement... 18:46:00 Voltage Offset Correction: v_off_ini = 477.055 uV, v_off_fin = 477.201 uV 18:46:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.878 uVs 18:46:00 Integrated Voltage Measurement... 18:46:09 Voltage Offset Correction: v_off_ini = 476.534 uV, v_off_fin = 480.572 uV 18:46:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.950 uVs 18:46:09 Integrated Voltage Measurement... 18:46:18 Voltage Offset Correction: v_off_ini = 479.018 uV, v_off_fin = 462.906 uV 18:46:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.277 uVs 18:46:18 Integrated Voltage Measurement... 18:46:27 Voltage Offset Correction: v_off_ini = 481.471 uV, v_off_fin = 477.519 uV 18:46:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.944 uVs 18:46:29 I2X Average and RMS of Measurements VT = -86.709 +- 8.473 uVs I2X = 7.977 +- 0.780 uTm^2 18:46:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:46:37 Integrated Voltage Measurement... 18:46:46 Voltage Offset Correction: v_off_ini = 464.767 uV, v_off_fin = 470.309 uV 18:46:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.833 uVs 18:46:46 Integrated Voltage Measurement... 18:46:55 Voltage Offset Correction: v_off_ini = 471.410 uV, v_off_fin = 482.426 uV 18:46:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.205 uVs 18:46:55 Integrated Voltage Measurement... 18:47:04 Voltage Offset Correction: v_off_ini = 486.303 uV, v_off_fin = 474.509 uV 18:47:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.491 uVs 18:47:04 Integrated Voltage Measurement... 18:47:13 Voltage Offset Correction: v_off_ini = 482.736 uV, v_off_fin = 484.312 uV 18:47:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.719 uVs 18:47:13 Integrated Voltage Measurement... 18:47:22 Voltage Offset Correction: v_off_ini = 479.849 uV, v_off_fin = 468.844 uV 18:47:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.975 uVs 18:47:22 Integrated Voltage Measurement... 18:47:31 Voltage Offset Correction: v_off_ini = 482.544 uV, v_off_fin = 496.024 uV 18:47:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.190 uVs 18:47:34 I2Y Average and RMS of Measurements VT = -197.235 +- 1.428 uVs I2Y = -18.146 +- 0.131 uTm^2 18:47:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:47:43 Integrated Voltage Measurement... 18:47:52 Voltage Offset Correction: v_off_ini = 483.208 uV, v_off_fin = 475.481 uV 18:47:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.202 uVs 18:47:52 Integrated Voltage Measurement... 18:48:01 Voltage Offset Correction: v_off_ini = 470.473 uV, v_off_fin = 479.031 uV 18:48:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.409 uVs 18:48:01 Integrated Voltage Measurement... 18:48:10 Voltage Offset Correction: v_off_ini = 475.194 uV, v_off_fin = 475.436 uV 18:48:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.397 uVs 18:48:10 Integrated Voltage Measurement... 18:48:19 Voltage Offset Correction: v_off_ini = 478.254 uV, v_off_fin = 479.757 uV 18:48:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.014 uVs 18:48:19 Integrated Voltage Measurement... 18:48:28 Voltage Offset Correction: v_off_ini = 483.241 uV, v_off_fin = 464.575 uV 18:48:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.599 uVs 18:48:28 Integrated Voltage Measurement... 18:48:37 Voltage Offset Correction: v_off_ini = 489.300 uV, v_off_fin = 477.966 uV 18:48:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.211 uVs 18:48:41 I1X Average and RMS of Measurements VT = -95.139 +- 3.420 uVs I1X = 19.028 +- 0.684 uTm 18:48:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:48:48 Integrated Voltage Measurement... 18:48:57 Voltage Offset Correction: v_off_ini = 468.266 uV, v_off_fin = 472.058 uV 18:48:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.120 uVs 18:48:57 Integrated Voltage Measurement... 18:49:06 Voltage Offset Correction: v_off_ini = 467.274 uV, v_off_fin = 489.030 uV 18:49:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.248 uVs 18:49:06 Integrated Voltage Measurement... 18:49:15 Voltage Offset Correction: v_off_ini = 490.163 uV, v_off_fin = 477.516 uV 18:49:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.833 uVs 18:49:15 Integrated Voltage Measurement... 18:49:24 Voltage Offset Correction: v_off_ini = 480.918 uV, v_off_fin = 488.933 uV 18:49:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.072 uVs 18:49:24 Integrated Voltage Measurement... 18:49:33 Voltage Offset Correction: v_off_ini = 485.981 uV, v_off_fin = 482.330 uV 18:49:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.301 uVs 18:49:33 Integrated Voltage Measurement... 18:49:42 Voltage Offset Correction: v_off_ini = 491.286 uV, v_off_fin = 500.640 uV 18:49:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.868 uVs 18:49:46 I1Y Average and RMS of Measurements VT = -198.574 +- 1.690 uVs I1Y = -39.715 +- 0.338 uTm 18:49:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:49:54 Integrated Voltage Measurement... 18:50:02 Voltage Offset Correction: v_off_ini = 497.056 uV, v_off_fin = 483.471 uV 18:50:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.327 uVs 18:50:03 Integrated Voltage Measurement... 18:50:12 Voltage Offset Correction: v_off_ini = 497.652 uV, v_off_fin = 488.043 uV 18:50:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.922 uVs 18:50:12 Integrated Voltage Measurement... 18:50:21 Voltage Offset Correction: v_off_ini = 492.711 uV, v_off_fin = 493.012 uV 18:50:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.027 uVs 18:50:21 Integrated Voltage Measurement... 18:50:30 Voltage Offset Correction: v_off_ini = 485.848 uV, v_off_fin = 500.908 uV 18:50:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.436 uVs 18:50:30 Integrated Voltage Measurement... 18:50:39 Voltage Offset Correction: v_off_ini = 505.327 uV, v_off_fin = 485.728 uV 18:50:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.090 uVs 18:50:39 Integrated Voltage Measurement... 18:50:48 Voltage Offset Correction: v_off_ini = 492.988 uV, v_off_fin = 493.899 uV 18:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.167 uVs 18:50:50 I2X Average and RMS of Measurements VT = -82.328 +- 6.203 uVs I2X = 7.574 +- 0.571 uTm^2 18:50:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:50:58 Integrated Voltage Measurement... 18:51:07 Voltage Offset Correction: v_off_ini = 492.182 uV, v_off_fin = 495.002 uV 18:51:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.744 uVs 18:51:07 Integrated Voltage Measurement... 18:51:16 Voltage Offset Correction: v_off_ini = 486.777 uV, v_off_fin = 492.915 uV 18:51:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.466 uVs 18:51:16 Integrated Voltage Measurement... 18:51:25 Voltage Offset Correction: v_off_ini = 491.715 uV, v_off_fin = 487.981 uV 18:51:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.762 uVs 18:51:25 Integrated Voltage Measurement... 18:51:34 Voltage Offset Correction: v_off_ini = 479.564 uV, v_off_fin = 482.020 uV 18:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.350 uVs 18:51:34 Integrated Voltage Measurement... 18:51:43 Voltage Offset Correction: v_off_ini = 481.047 uV, v_off_fin = 483.074 uV 18:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.785 uVs 18:51:43 Integrated Voltage Measurement... 18:51:52 Voltage Offset Correction: v_off_ini = 484.711 uV, v_off_fin = 489.032 uV 18:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.516 uVs 18:51:54 I2Y Average and RMS of Measurements VT = -196.437 +- 5.170 uVs I2Y = -18.072 +- 0.476 uTm^2 18:51:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:52:03 Integrated Voltage Measurement... 18:52:12 Voltage Offset Correction: v_off_ini = 484.077 uV, v_off_fin = 487.017 uV 18:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.412 uVs 18:52:12 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = 489.670 uV, v_off_fin = 492.459 uV 18:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.781 uVs 18:52:21 Integrated Voltage Measurement... 18:52:30 Voltage Offset Correction: v_off_ini = 487.909 uV, v_off_fin = 480.453 uV 18:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.691 uVs 18:52:30 Integrated Voltage Measurement... 18:52:39 Voltage Offset Correction: v_off_ini = 475.802 uV, v_off_fin = 473.291 uV 18:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.317 uVs 18:52:39 Integrated Voltage Measurement... 18:52:48 Voltage Offset Correction: v_off_ini = 490.479 uV, v_off_fin = 485.129 uV 18:52:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.999 uVs 18:52:48 Integrated Voltage Measurement... 18:52:57 Voltage Offset Correction: v_off_ini = 480.622 uV, v_off_fin = 477.438 uV 18:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.499 uVs 18:53:01 I1X Average and RMS of Measurements VT = -98.783 +- 0.983 uVs I1X = 19.757 +- 0.196 uTm 18:53:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:53:08 Integrated Voltage Measurement... 18:53:17 Voltage Offset Correction: v_off_ini = 469.686 uV, v_off_fin = 460.687 uV 18:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.907 uVs 18:53:17 Integrated Voltage Measurement... 18:53:26 Voltage Offset Correction: v_off_ini = 463.476 uV, v_off_fin = 473.924 uV 18:53:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.822 uVs 18:53:26 Integrated Voltage Measurement... 18:53:35 Voltage Offset Correction: v_off_ini = 483.545 uV, v_off_fin = 458.626 uV 18:53:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.326 uVs 18:53:35 Integrated Voltage Measurement... 18:53:44 Voltage Offset Correction: v_off_ini = 477.035 uV, v_off_fin = 484.274 uV 18:53:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 191.366 uVs 18:53:44 Integrated Voltage Measurement... 18:53:53 Voltage Offset Correction: v_off_ini = 473.048 uV, v_off_fin = 459.603 uV 18:53:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.967 uVs 18:53:53 Integrated Voltage Measurement... 18:54:02 Voltage Offset Correction: v_off_ini = 465.733 uV, v_off_fin = 477.936 uV 18:54:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.029 uVs 18:54:06 I1Y Average and RMS of Measurements VT = -197.403 +- 7.787 uVs I1Y = -39.481 +- 1.557 uTm 18:54:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:54:14 Integrated Voltage Measurement... 18:54:23 Voltage Offset Correction: v_off_ini = 460.258 uV, v_off_fin = 461.764 uV 18:54:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.431 uVs 18:54:23 Integrated Voltage Measurement... 18:54:32 Voltage Offset Correction: v_off_ini = 474.277 uV, v_off_fin = 479.211 uV 18:54:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.039 uVs 18:54:32 Integrated Voltage Measurement... 18:54:41 Voltage Offset Correction: v_off_ini = 480.988 uV, v_off_fin = 473.943 uV 18:54:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.637 uVs 18:54:41 Integrated Voltage Measurement... 18:54:50 Voltage Offset Correction: v_off_ini = 487.257 uV, v_off_fin = 487.912 uV 18:54:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.480 uVs 18:54:50 Integrated Voltage Measurement... 18:54:59 Voltage Offset Correction: v_off_ini = 482.578 uV, v_off_fin = 476.358 uV 18:54:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.381 uVs 18:54:59 Integrated Voltage Measurement... 18:55:08 Voltage Offset Correction: v_off_ini = 483.387 uV, v_off_fin = 489.394 uV 18:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.770 uVs 18:55:11 I2X Average and RMS of Measurements VT = -89.290 +- 7.538 uVs I2X = 8.215 +- 0.693 uTm^2 18:55:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:55:18 Integrated Voltage Measurement... 18:55:27 Voltage Offset Correction: v_off_ini = 484.849 uV, v_off_fin = 479.776 uV 18:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.774 uVs 18:55:27 Integrated Voltage Measurement... 18:55:36 Voltage Offset Correction: v_off_ini = 479.384 uV, v_off_fin = 484.392 uV 18:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.604 uVs 18:55:37 Integrated Voltage Measurement... 18:55:46 Voltage Offset Correction: v_off_ini = 472.928 uV, v_off_fin = 476.878 uV 18:55:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -192.686 uVs 18:55:46 Integrated Voltage Measurement... 18:55:55 Voltage Offset Correction: v_off_ini = 483.564 uV, v_off_fin = 473.152 uV 18:55:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.548 uVs 18:55:55 Integrated Voltage Measurement... 18:56:04 Voltage Offset Correction: v_off_ini = 483.223 uV, v_off_fin = 473.810 uV 18:56:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.151 uVs 18:56:04 Integrated Voltage Measurement... 18:56:13 Voltage Offset Correction: v_off_ini = 469.813 uV, v_off_fin = 471.526 uV 18:56:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.915 uVs 18:56:15 I2Y Average and RMS of Measurements VT = -200.113 +- 5.950 uVs I2Y = -18.411 +- 0.548 uTm^2 18:56:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:56:27 Integrated Voltage Measurement... 18:56:36 Voltage Offset Correction: v_off_ini = 470.569 uV, v_off_fin = 464.112 uV 18:56:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.236 uVs 18:56:36 Integrated Voltage Measurement... 18:56:45 Voltage Offset Correction: v_off_ini = 467.807 uV, v_off_fin = 476.866 uV 18:56:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.867 uVs 18:56:45 Integrated Voltage Measurement... 18:56:54 Voltage Offset Correction: v_off_ini = 475.632 uV, v_off_fin = 479.596 uV 18:56:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.567 uVs 18:56:54 Integrated Voltage Measurement... 18:57:03 Voltage Offset Correction: v_off_ini = 489.361 uV, v_off_fin = 478.481 uV 18:57:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.263 uVs 18:57:03 Integrated Voltage Measurement... 18:57:12 Voltage Offset Correction: v_off_ini = 476.957 uV, v_off_fin = 480.775 uV 18:57:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.694 uVs 18:57:12 Integrated Voltage Measurement... 18:57:21 Voltage Offset Correction: v_off_ini = 481.235 uV, v_off_fin = 470.778 uV 18:57:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.610 uVs 18:57:25 I1X Average and RMS of Measurements VT = -76.040 +- 2.409 uVs I1X = 15.208 +- 0.482 uTm 18:57:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:57:32 Integrated Voltage Measurement... 18:57:41 Voltage Offset Correction: v_off_ini = 469.454 uV, v_off_fin = 455.947 uV 18:57:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.683 uVs 18:57:41 Integrated Voltage Measurement... 18:57:50 Voltage Offset Correction: v_off_ini = 477.820 uV, v_off_fin = 484.690 uV 18:57:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.812 uVs 18:57:50 Integrated Voltage Measurement... 18:57:59 Voltage Offset Correction: v_off_ini = 473.304 uV, v_off_fin = 473.792 uV 18:57:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.502 uVs 18:57:59 Integrated Voltage Measurement... 18:58:08 Voltage Offset Correction: v_off_ini = 465.365 uV, v_off_fin = 475.915 uV 18:58:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.620 uVs 18:58:08 Integrated Voltage Measurement... 18:58:17 Voltage Offset Correction: v_off_ini = 470.460 uV, v_off_fin = 463.279 uV 18:58:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.215 uVs 18:58:17 Integrated Voltage Measurement... 18:58:26 Voltage Offset Correction: v_off_ini = 477.547 uV, v_off_fin = 480.953 uV 18:58:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.840 uVs 18:58:30 I1Y Average and RMS of Measurements VT = -199.112 +- 7.782 uVs I1Y = -39.822 +- 1.556 uTm 18:58:33 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:58:35 Integrated Voltage Measurement... 18:58:44 Voltage Offset Correction: v_off_ini = 471.473 uV, v_off_fin = 470.128 uV 18:58:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.363 uVs 18:58:44 Integrated Voltage Measurement... 18:58:53 Voltage Offset Correction: v_off_ini = 468.514 uV, v_off_fin = 480.513 uV 18:58:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.617 uVs 18:58:53 Integrated Voltage Measurement... 18:59:02 Voltage Offset Correction: v_off_ini = 483.110 uV, v_off_fin = 468.422 uV 18:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.864 uVs 18:59:02 Integrated Voltage Measurement... 18:59:11 Voltage Offset Correction: v_off_ini = 481.271 uV, v_off_fin = 486.910 uV 18:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.331 uVs 18:59:12 Integrated Voltage Measurement... 18:59:20 Voltage Offset Correction: v_off_ini = 479.100 uV, v_off_fin = 471.692 uV 18:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.719 uVs 18:59:21 Integrated Voltage Measurement... 18:59:30 Voltage Offset Correction: v_off_ini = 481.005 uV, v_off_fin = 488.113 uV 18:59:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.755 uVs 18:59:32 I2X Average and RMS of Measurements VT = -75.442 +- 2.622 uVs I2X = 6.941 +- 0.241 uTm^2 18:59:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:59:37 Integrated Voltage Measurement... 18:59:46 Voltage Offset Correction: v_off_ini = 475.162 uV, v_off_fin = 479.492 uV 18:59:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.733 uVs 18:59:46 Integrated Voltage Measurement... 18:59:55 Voltage Offset Correction: v_off_ini = 476.184 uV, v_off_fin = 479.330 uV 18:59:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.670 uVs 18:59:55 Integrated Voltage Measurement... 19:00:04 Voltage Offset Correction: v_off_ini = 479.082 uV, v_off_fin = 486.882 uV 19:00:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.480 uVs 19:00:04 Integrated Voltage Measurement... 19:00:13 Voltage Offset Correction: v_off_ini = 487.548 uV, v_off_fin = 488.967 uV 19:00:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.455 uVs 19:00:13 Integrated Voltage Measurement... 19:00:22 Voltage Offset Correction: v_off_ini = 501.991 uV, v_off_fin = 490.228 uV 19:00:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.635 uVs 19:00:22 Integrated Voltage Measurement... 19:00:31 Voltage Offset Correction: v_off_ini = 482.090 uV, v_off_fin = 488.310 uV 19:00:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.885 uVs 19:00:34 I2Y Average and RMS of Measurements VT = -200.976 +- 3.153 uVs I2Y = -18.490 +- 0.290 uTm^2 19:00:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:00:42 Integrated Voltage Measurement... 19:00:51 Voltage Offset Correction: v_off_ini = 474.623 uV, v_off_fin = 485.859 uV 19:00:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.203 uVs 19:00:51 Integrated Voltage Measurement... 19:01:00 Voltage Offset Correction: v_off_ini = 487.465 uV, v_off_fin = 480.705 uV 19:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.077 uVs 19:01:00 Integrated Voltage Measurement... 19:01:09 Voltage Offset Correction: v_off_ini = 476.993 uV, v_off_fin = 487.600 uV 19:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.967 uVs 19:01:09 Integrated Voltage Measurement... 19:01:18 Voltage Offset Correction: v_off_ini = 485.719 uV, v_off_fin = 488.635 uV 19:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.969 uVs 19:01:18 Integrated Voltage Measurement... 19:01:27 Voltage Offset Correction: v_off_ini = 485.477 uV, v_off_fin = 482.274 uV 19:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.113 uVs 19:01:27 Integrated Voltage Measurement... 19:01:36 Voltage Offset Correction: v_off_ini = 485.541 uV, v_off_fin = 479.827 uV 19:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.543 uVs 19:01:40 I1X Average and RMS of Measurements VT = -85.645 +- 5.459 uVs I1X = 17.129 +- 1.092 uTm 19:01:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:01:47 Integrated Voltage Measurement... 19:01:56 Voltage Offset Correction: v_off_ini = 485.798 uV, v_off_fin = 467.981 uV 19:01:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.258 uVs 19:01:56 Integrated Voltage Measurement... 19:02:05 Voltage Offset Correction: v_off_ini = 475.393 uV, v_off_fin = 491.559 uV 19:02:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.633 uVs 19:02:05 Integrated Voltage Measurement... 19:02:14 Voltage Offset Correction: v_off_ini = 484.558 uV, v_off_fin = 474.161 uV 19:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.664 uVs 19:02:14 Integrated Voltage Measurement... 19:02:23 Voltage Offset Correction: v_off_ini = 465.485 uV, v_off_fin = 488.123 uV 19:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.191 uVs 19:02:23 Integrated Voltage Measurement... 19:02:32 Voltage Offset Correction: v_off_ini = 481.532 uV, v_off_fin = 465.836 uV 19:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.034 uVs 19:02:32 Integrated Voltage Measurement... 19:02:41 Voltage Offset Correction: v_off_ini = 487.227 uV, v_off_fin = 490.519 uV 19:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.372 uVs 19:02:45 I1Y Average and RMS of Measurements VT = -207.525 +- 5.369 uVs I1Y = -41.505 +- 1.074 uTm 19:02:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:02:50 Integrated Voltage Measurement... 19:02:59 Voltage Offset Correction: v_off_ini = 480.663 uV, v_off_fin = 475.664 uV 19:02:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.330 uVs 19:02:59 Integrated Voltage Measurement... 19:03:08 Voltage Offset Correction: v_off_ini = 491.716 uV, v_off_fin = 487.528 uV 19:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.563 uVs 19:03:08 Integrated Voltage Measurement... 19:03:17 Voltage Offset Correction: v_off_ini = 484.284 uV, v_off_fin = 483.424 uV 19:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.839 uVs 19:03:17 Integrated Voltage Measurement... 19:03:26 Voltage Offset Correction: v_off_ini = 478.606 uV, v_off_fin = 480.361 uV 19:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.076 uVs 19:03:26 Integrated Voltage Measurement... 19:03:35 Voltage Offset Correction: v_off_ini = 470.116 uV, v_off_fin = 468.199 uV 19:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.769 uVs 19:03:35 Integrated Voltage Measurement... 19:03:44 Voltage Offset Correction: v_off_ini = 489.498 uV, v_off_fin = 484.306 uV 19:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.732 uVs 19:03:47 I2X Average and RMS of Measurements VT = -77.551 +- 7.637 uVs I2X = 7.135 +- 0.703 uTm^2 19:03:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:03:52 Integrated Voltage Measurement... 19:04:01 Voltage Offset Correction: v_off_ini = 475.378 uV, v_off_fin = 482.456 uV 19:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.169 uVs 19:04:01 Integrated Voltage Measurement... 19:04:10 Voltage Offset Correction: v_off_ini = 486.996 uV, v_off_fin = 478.711 uV 19:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.653 uVs 19:04:10 Integrated Voltage Measurement... 19:04:19 Voltage Offset Correction: v_off_ini = 480.524 uV, v_off_fin = 481.051 uV 19:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.186 uVs 19:04:19 Integrated Voltage Measurement... 19:04:28 Voltage Offset Correction: v_off_ini = 484.347 uV, v_off_fin = 479.270 uV 19:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.897 uVs 19:04:28 Integrated Voltage Measurement... 19:04:37 Voltage Offset Correction: v_off_ini = 489.803 uV, v_off_fin = 485.108 uV 19:04:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.557 uVs 19:04:37 Integrated Voltage Measurement... 19:04:46 Voltage Offset Correction: v_off_ini = 490.435 uV, v_off_fin = 484.286 uV 19:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.482 uVs 19:04:49 I2Y Average and RMS of Measurements VT = -195.324 +- 10.975 uVs I2Y = -17.970 +- 1.010 uTm^2 19:04:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:04:57 Integrated Voltage Measurement... 19:05:06 Voltage Offset Correction: v_off_ini = 491.567 uV, v_off_fin = 487.927 uV 19:05:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.826 uVs 19:05:06 Integrated Voltage Measurement... 19:05:15 Voltage Offset Correction: v_off_ini = 497.231 uV, v_off_fin = 495.749 uV 19:05:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.992 uVs 19:05:15 Integrated Voltage Measurement... 19:05:24 Voltage Offset Correction: v_off_ini = 489.614 uV, v_off_fin = 487.781 uV 19:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.048 uVs 19:05:24 Integrated Voltage Measurement... 19:05:33 Voltage Offset Correction: v_off_ini = 478.268 uV, v_off_fin = 480.275 uV 19:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.837 uVs 19:05:33 Integrated Voltage Measurement... 19:05:42 Voltage Offset Correction: v_off_ini = 479.230 uV, v_off_fin = 470.891 uV 19:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.044 uVs 19:05:42 Integrated Voltage Measurement... 19:05:51 Voltage Offset Correction: v_off_ini = 483.802 uV, v_off_fin = 488.025 uV 19:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.968 uVs 19:05:55 I1X Average and RMS of Measurements VT = -86.953 +- 6.061 uVs I1X = 17.391 +- 1.212 uTm 19:05:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:06:02 Integrated Voltage Measurement... 19:06:11 Voltage Offset Correction: v_off_ini = 503.341 uV, v_off_fin = 481.259 uV 19:06:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.683 uVs 19:06:11 Integrated Voltage Measurement... 19:06:20 Voltage Offset Correction: v_off_ini = 491.843 uV, v_off_fin = 512.155 uV 19:06:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.626 uVs 19:06:20 Integrated Voltage Measurement... 19:06:29 Voltage Offset Correction: v_off_ini = 501.533 uV, v_off_fin = 483.405 uV 19:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.980 uVs 19:06:29 Integrated Voltage Measurement... 19:06:38 Voltage Offset Correction: v_off_ini = 497.372 uV, v_off_fin = 507.773 uV 19:06:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.630 uVs 19:06:38 Integrated Voltage Measurement... 19:06:47 Voltage Offset Correction: v_off_ini = 500.692 uV, v_off_fin = 487.488 uV 19:06:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.006 uVs 19:06:47 Integrated Voltage Measurement... 19:06:56 Voltage Offset Correction: v_off_ini = 492.682 uV, v_off_fin = 501.337 uV 19:06:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.443 uVs 19:07:00 I1Y Average and RMS of Measurements VT = -202.395 +- 5.750 uVs I1Y = -40.479 +- 1.150 uTm 19:07:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:07:05 Integrated Voltage Measurement... 19:07:14 Voltage Offset Correction: v_off_ini = 486.243 uV, v_off_fin = 493.336 uV 19:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.769 uVs 19:07:14 Integrated Voltage Measurement... 19:07:23 Voltage Offset Correction: v_off_ini = 487.430 uV, v_off_fin = 501.315 uV 19:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.710 uVs 19:07:23 Integrated Voltage Measurement... 19:07:32 Voltage Offset Correction: v_off_ini = 502.211 uV, v_off_fin = 486.005 uV 19:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.982 uVs 19:07:32 Integrated Voltage Measurement... 19:07:41 Voltage Offset Correction: v_off_ini = 486.968 uV, v_off_fin = 498.406 uV 19:07:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.520 uVs 19:07:41 Integrated Voltage Measurement... 19:07:50 Voltage Offset Correction: v_off_ini = 493.523 uV, v_off_fin = 487.220 uV 19:07:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.224 uVs 19:07:50 Integrated Voltage Measurement... 19:07:59 Voltage Offset Correction: v_off_ini = 486.872 uV, v_off_fin = 493.724 uV 19:07:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.364 uVs 19:08:02 I2X Average and RMS of Measurements VT = -93.595 +- 6.146 uVs I2X = 8.611 +- 0.565 uTm^2 19:08:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:08:07 Integrated Voltage Measurement... 19:08:16 Voltage Offset Correction: v_off_ini = 470.091 uV, v_off_fin = 481.161 uV 19:08:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.610 uVs 19:08:16 Integrated Voltage Measurement... 19:08:25 Voltage Offset Correction: v_off_ini = 483.065 uV, v_off_fin = 481.320 uV 19:08:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.816 uVs 19:08:25 Integrated Voltage Measurement... 19:08:34 Voltage Offset Correction: v_off_ini = 492.172 uV, v_off_fin = 488.434 uV 19:08:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.866 uVs 19:08:34 Integrated Voltage Measurement... 19:08:43 Voltage Offset Correction: v_off_ini = 487.544 uV, v_off_fin = 483.307 uV 19:08:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.856 uVs 19:08:43 Integrated Voltage Measurement... 19:08:52 Voltage Offset Correction: v_off_ini = 487.887 uV, v_off_fin = 479.146 uV 19:08:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.338 uVs 19:08:52 Integrated Voltage Measurement... 19:09:01 Voltage Offset Correction: v_off_ini = 478.272 uV, v_off_fin = 478.839 uV 19:09:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.848 uVs 19:09:04 I2Y Average and RMS of Measurements VT = -203.556 +- 7.036 uVs I2Y = -18.727 +- 0.647 uTm^2 19:09:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:09:12 Integrated Voltage Measurement... 19:09:21 Voltage Offset Correction: v_off_ini = 495.011 uV, v_off_fin = 495.441 uV 19:09:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.496 uVs 19:09:21 Integrated Voltage Measurement... 19:09:30 Voltage Offset Correction: v_off_ini = 494.695 uV, v_off_fin = 489.953 uV 19:09:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.323 uVs 19:09:30 Integrated Voltage Measurement... 19:09:39 Voltage Offset Correction: v_off_ini = 492.301 uV, v_off_fin = 484.772 uV 19:09:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.474 uVs 19:09:39 Integrated Voltage Measurement... 19:09:48 Voltage Offset Correction: v_off_ini = 485.698 uV, v_off_fin = 484.055 uV 19:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.360 uVs 19:09:48 Integrated Voltage Measurement... 19:09:57 Voltage Offset Correction: v_off_ini = 487.137 uV, v_off_fin = 481.241 uV 19:09:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.343 uVs 19:09:57 Integrated Voltage Measurement... 19:10:06 Voltage Offset Correction: v_off_ini = 490.475 uV, v_off_fin = 490.428 uV 19:10:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.323 uVs 19:10:10 I1X Average and RMS of Measurements VT = -87.553 +- 4.181 uVs I1X = 17.511 +- 0.837 uTm 19:10:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:10:17 Integrated Voltage Measurement... 19:10:26 Voltage Offset Correction: v_off_ini = 497.172 uV, v_off_fin = 481.333 uV 19:10:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.892 uVs 19:10:26 Integrated Voltage Measurement... 19:10:35 Voltage Offset Correction: v_off_ini = 508.528 uV, v_off_fin = 510.223 uV 19:10:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.737 uVs 19:10:35 Integrated Voltage Measurement... 19:10:44 Voltage Offset Correction: v_off_ini = 499.925 uV, v_off_fin = 484.359 uV 19:10:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.046 uVs 19:10:44 Integrated Voltage Measurement... 19:10:53 Voltage Offset Correction: v_off_ini = 505.647 uV, v_off_fin = 514.682 uV 19:10:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.331 uVs 19:10:53 Integrated Voltage Measurement... 19:11:02 Voltage Offset Correction: v_off_ini = 498.775 uV, v_off_fin = 485.300 uV 19:11:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.465 uVs 19:11:02 Integrated Voltage Measurement... 19:11:11 Voltage Offset Correction: v_off_ini = 487.303 uV, v_off_fin = 498.922 uV 19:11:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.084 uVs 19:11:15 I1Y Average and RMS of Measurements VT = -203.426 +- 3.708 uVs I1Y = -40.682 +- 0.742 uTm 19:11:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:11:20 Integrated Voltage Measurement... 19:11:29 Voltage Offset Correction: v_off_ini = 483.908 uV, v_off_fin = 487.954 uV 19:11:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.671 uVs 19:11:29 Integrated Voltage Measurement... 19:11:38 Voltage Offset Correction: v_off_ini = 488.672 uV, v_off_fin = 489.401 uV 19:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.764 uVs 19:11:38 Integrated Voltage Measurement... 19:11:47 Voltage Offset Correction: v_off_ini = 483.591 uV, v_off_fin = 477.125 uV 19:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.922 uVs 19:11:47 Integrated Voltage Measurement... 19:11:56 Voltage Offset Correction: v_off_ini = 495.560 uV, v_off_fin = 491.604 uV 19:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.811 uVs 19:11:56 Integrated Voltage Measurement... 19:12:05 Voltage Offset Correction: v_off_ini = 489.509 uV, v_off_fin = 481.066 uV 19:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.200 uVs 19:12:05 Integrated Voltage Measurement... 19:12:14 Voltage Offset Correction: v_off_ini = 491.356 uV, v_off_fin = 492.582 uV 19:12:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.082 uVs 19:12:17 I2X Average and RMS of Measurements VT = -84.575 +- 2.632 uVs I2X = 7.781 +- 0.242 uTm^2 19:12:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:12:22 Integrated Voltage Measurement... 19:12:31 Voltage Offset Correction: v_off_ini = 485.703 uV, v_off_fin = 491.025 uV 19:12:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.134 uVs 19:12:31 Integrated Voltage Measurement... 19:12:40 Voltage Offset Correction: v_off_ini = 493.634 uV, v_off_fin = 501.307 uV 19:12:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.267 uVs 19:12:40 Integrated Voltage Measurement... 19:12:49 Voltage Offset Correction: v_off_ini = 508.324 uV, v_off_fin = 498.531 uV 19:12:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.477 uVs 19:12:49 Integrated Voltage Measurement... 19:12:58 Voltage Offset Correction: v_off_ini = 498.047 uV, v_off_fin = 501.702 uV 19:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.810 uVs 19:12:58 Integrated Voltage Measurement... 19:13:07 Voltage Offset Correction: v_off_ini = 502.376 uV, v_off_fin = 493.637 uV 19:13:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.146 uVs 19:13:07 Integrated Voltage Measurement... 19:13:16 Voltage Offset Correction: v_off_ini = 499.747 uV, v_off_fin = 502.251 uV 19:13:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.196 uVs 19:13:19 I2Y Average and RMS of Measurements VT = -194.672 +- 5.340 uVs I2Y = -17.910 +- 0.492 uTm^2 19:13:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:13:27 Integrated Voltage Measurement... 19:13:36 Voltage Offset Correction: v_off_ini = 493.019 uV, v_off_fin = 491.078 uV 19:13:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.761 uVs 19:13:36 Integrated Voltage Measurement... 19:13:45 Voltage Offset Correction: v_off_ini = 493.754 uV, v_off_fin = 490.089 uV 19:13:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.128 uVs 19:13:45 Integrated Voltage Measurement... 19:13:54 Voltage Offset Correction: v_off_ini = 489.759 uV, v_off_fin = 487.646 uV 19:13:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.118 uVs 19:13:54 Integrated Voltage Measurement... 19:14:03 Voltage Offset Correction: v_off_ini = 502.566 uV, v_off_fin = 496.212 uV 19:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.898 uVs 19:14:03 Integrated Voltage Measurement... 19:14:12 Voltage Offset Correction: v_off_ini = 495.440 uV, v_off_fin = 493.848 uV 19:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.012 uVs 19:14:12 Integrated Voltage Measurement... 19:14:21 Voltage Offset Correction: v_off_ini = 493.048 uV, v_off_fin = 505.961 uV 19:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.594 uVs 19:14:25 I1X Average and RMS of Measurements VT = -77.919 +- 8.373 uVs I1X = 15.584 +- 1.675 uTm 19:14:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:14:32 Integrated Voltage Measurement... 19:14:41 Voltage Offset Correction: v_off_ini = 491.269 uV, v_off_fin = 489.005 uV 19:14:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.865 uVs 19:14:41 Integrated Voltage Measurement... 19:14:50 Voltage Offset Correction: v_off_ini = 490.544 uV, v_off_fin = 512.559 uV 19:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.564 uVs 19:14:50 Integrated Voltage Measurement... 19:14:59 Voltage Offset Correction: v_off_ini = 490.556 uV, v_off_fin = 485.717 uV 19:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.895 uVs 19:14:59 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = 503.657 uV, v_off_fin = 517.033 uV 19:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 191.633 uVs 19:15:08 Integrated Voltage Measurement... 19:15:17 Voltage Offset Correction: v_off_ini = 503.120 uV, v_off_fin = 502.191 uV 19:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.686 uVs 19:15:17 Integrated Voltage Measurement... 19:15:26 Voltage Offset Correction: v_off_ini = 507.731 uV, v_off_fin = 508.262 uV 19:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.351 uVs 19:15:30 I1Y Average and RMS of Measurements VT = -198.166 +- 4.478 uVs I1Y = -39.631 +- 0.896 uTm 19:15:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:15:35 Integrated Voltage Measurement... 19:15:44 Voltage Offset Correction: v_off_ini = 504.704 uV, v_off_fin = 499.335 uV 19:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.797 uVs 19:15:44 Integrated Voltage Measurement... 19:15:53 Voltage Offset Correction: v_off_ini = 502.208 uV, v_off_fin = 509.210 uV 19:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.288 uVs 19:15:53 Integrated Voltage Measurement... 19:16:02 Voltage Offset Correction: v_off_ini = 517.724 uV, v_off_fin = 508.193 uV 19:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.507 uVs 19:16:02 Integrated Voltage Measurement... 19:16:11 Voltage Offset Correction: v_off_ini = 499.877 uV, v_off_fin = 514.644 uV 19:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.297 uVs 19:16:12 Integrated Voltage Measurement... 19:16:20 Voltage Offset Correction: v_off_ini = 522.484 uV, v_off_fin = 498.379 uV 19:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.913 uVs 19:16:21 Integrated Voltage Measurement... 19:16:30 Voltage Offset Correction: v_off_ini = 512.214 uV, v_off_fin = 510.196 uV 19:16:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.464 uVs 19:16:32 I2X Average and RMS of Measurements VT = -84.711 +- 4.828 uVs I2X = 7.793 +- 0.444 uTm^2 19:16:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:16:37 Integrated Voltage Measurement... 19:16:46 Voltage Offset Correction: v_off_ini = 498.758 uV, v_off_fin = 507.271 uV 19:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.810 uVs 19:16:46 Integrated Voltage Measurement... 19:16:55 Voltage Offset Correction: v_off_ini = 504.928 uV, v_off_fin = 503.803 uV 19:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.792 uVs 19:16:55 Integrated Voltage Measurement... 19:17:04 Voltage Offset Correction: v_off_ini = 511.071 uV, v_off_fin = 500.684 uV 19:17:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.615 uVs 19:17:04 Integrated Voltage Measurement... 19:17:13 Voltage Offset Correction: v_off_ini = 497.080 uV, v_off_fin = 499.688 uV 19:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.220 uVs 19:17:13 Integrated Voltage Measurement... 19:17:22 Voltage Offset Correction: v_off_ini = 501.192 uV, v_off_fin = 495.261 uV 19:17:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.049 uVs 19:17:22 Integrated Voltage Measurement... 19:17:31 Voltage Offset Correction: v_off_ini = 508.718 uV, v_off_fin = 511.536 uV 19:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.916 uVs 19:17:34 I2Y Average and RMS of Measurements VT = -202.567 +- 5.223 uVs I2Y = -18.636 +- 0.480 uTm^2 19:17:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:17:55 Integrated Voltage Measurement... 19:18:04 Voltage Offset Correction: v_off_ini = 494.798 uV, v_off_fin = 497.191 uV 19:18:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.550 uVs 19:18:04 Integrated Voltage Measurement... 19:18:13 Voltage Offset Correction: v_off_ini = 488.477 uV, v_off_fin = 497.368 uV 19:18:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.405 uVs 19:18:13 Integrated Voltage Measurement... 19:18:22 Voltage Offset Correction: v_off_ini = 490.525 uV, v_off_fin = 489.938 uV 19:18:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.522 uVs 19:18:22 Integrated Voltage Measurement... 19:18:31 Voltage Offset Correction: v_off_ini = 491.430 uV, v_off_fin = 487.586 uV 19:18:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.937 uVs 19:18:31 Integrated Voltage Measurement... 19:18:40 Voltage Offset Correction: v_off_ini = 493.575 uV, v_off_fin = 489.267 uV 19:18:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.216 uVs 19:18:40 Integrated Voltage Measurement... 19:18:49 Voltage Offset Correction: v_off_ini = 483.901 uV, v_off_fin = 484.009 uV 19:18:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.028 uVs 19:18:53 I1X Average and RMS of Measurements VT = -92.276 +- 13.282 uVs I1X = 18.456 +- 2.657 uTm 19:18:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:19:00 Integrated Voltage Measurement... 19:19:09 Voltage Offset Correction: v_off_ini = 481.051 uV, v_off_fin = 476.768 uV 19:19:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.770 uVs 19:19:09 Integrated Voltage Measurement... 19:19:18 Voltage Offset Correction: v_off_ini = 485.739 uV, v_off_fin = 484.053 uV 19:19:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.144 uVs 19:19:18 Integrated Voltage Measurement... 19:19:27 Voltage Offset Correction: v_off_ini = 483.660 uV, v_off_fin = 472.706 uV 19:19:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.601 uVs 19:19:27 Integrated Voltage Measurement... 19:19:36 Voltage Offset Correction: v_off_ini = 488.900 uV, v_off_fin = 508.610 uV 19:19:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.148 uVs 19:19:36 Integrated Voltage Measurement... 19:19:45 Voltage Offset Correction: v_off_ini = 473.643 uV, v_off_fin = 474.288 uV 19:19:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.531 uVs 19:19:45 Integrated Voltage Measurement... 19:19:54 Voltage Offset Correction: v_off_ini = 484.984 uV, v_off_fin = 500.141 uV 19:19:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.968 uVs 19:19:58 I1Y Average and RMS of Measurements VT = -200.194 +- 2.237 uVs I1Y = -40.039 +- 0.447 uTm 19:20:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:20:06 Integrated Voltage Measurement... 19:20:15 Voltage Offset Correction: v_off_ini = 482.531 uV, v_off_fin = 483.016 uV 19:20:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.464 uVs 19:20:15 Integrated Voltage Measurement... 19:20:24 Voltage Offset Correction: v_off_ini = 494.398 uV, v_off_fin = 497.895 uV 19:20:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.685 uVs 19:20:24 Integrated Voltage Measurement... 19:20:33 Voltage Offset Correction: v_off_ini = 468.025 uV, v_off_fin = 480.364 uV 19:20:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.993 uVs 19:20:33 Integrated Voltage Measurement... 19:20:42 Voltage Offset Correction: v_off_ini = 476.002 uV, v_off_fin = 488.075 uV 19:20:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.474 uVs 19:20:42 Integrated Voltage Measurement... 19:20:51 Voltage Offset Correction: v_off_ini = 482.181 uV, v_off_fin = 479.653 uV 19:20:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.715 uVs 19:20:51 Integrated Voltage Measurement... 19:21:00 Voltage Offset Correction: v_off_ini = 485.756 uV, v_off_fin = 492.342 uV 19:21:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.999 uVs 19:21:02 I2X Average and RMS of Measurements VT = -87.888 +- 6.608 uVs I2X = 8.086 +- 0.608 uTm^2 19:21:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:21:10 Integrated Voltage Measurement... 19:21:19 Voltage Offset Correction: v_off_ini = 489.768 uV, v_off_fin = 484.507 uV 19:21:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.668 uVs 19:21:19 Integrated Voltage Measurement... 19:21:28 Voltage Offset Correction: v_off_ini = 492.026 uV, v_off_fin = 494.510 uV 19:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.360 uVs 19:21:28 Integrated Voltage Measurement... 19:21:37 Voltage Offset Correction: v_off_ini = 484.540 uV, v_off_fin = 498.568 uV 19:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.248 uVs 19:21:37 Integrated Voltage Measurement... 19:21:46 Voltage Offset Correction: v_off_ini = 492.436 uV, v_off_fin = 503.499 uV 19:21:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.038 uVs 19:21:46 Integrated Voltage Measurement... 19:21:55 Voltage Offset Correction: v_off_ini = 485.930 uV, v_off_fin = 489.898 uV 19:21:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.912 uVs 19:21:55 Integrated Voltage Measurement... 19:22:04 Voltage Offset Correction: v_off_ini = 478.530 uV, v_off_fin = 487.727 uV 19:22:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.537 uVs 19:22:07 I2Y Average and RMS of Measurements VT = -189.627 +- 5.311 uVs I2Y = -17.446 +- 0.489 uTm^2 19:22:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:22:16 Integrated Voltage Measurement... 19:22:25 Voltage Offset Correction: v_off_ini = 501.755 uV, v_off_fin = 492.752 uV 19:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.537 uVs 19:22:25 Integrated Voltage Measurement... 19:22:34 Voltage Offset Correction: v_off_ini = 485.641 uV, v_off_fin = 488.380 uV 19:22:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.859 uVs 19:22:34 Integrated Voltage Measurement... 19:22:43 Voltage Offset Correction: v_off_ini = 482.668 uV, v_off_fin = 483.674 uV 19:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.115 uVs 19:22:43 Integrated Voltage Measurement... 19:22:52 Voltage Offset Correction: v_off_ini = 486.043 uV, v_off_fin = 489.061 uV 19:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.196 uVs 19:22:52 Integrated Voltage Measurement... 19:23:01 Voltage Offset Correction: v_off_ini = 490.529 uV, v_off_fin = 492.144 uV 19:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.915 uVs 19:23:01 Integrated Voltage Measurement... 19:23:10 Voltage Offset Correction: v_off_ini = 487.143 uV, v_off_fin = 486.780 uV 19:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.500 uVs 19:23:14 I1X Average and RMS of Measurements VT = -93.854 +- 0.638 uVs I1X = 18.771 +- 0.128 uTm 19:23:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:23:21 Integrated Voltage Measurement... 19:23:30 Voltage Offset Correction: v_off_ini = 504.997 uV, v_off_fin = 496.168 uV 19:23:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.652 uVs 19:23:30 Integrated Voltage Measurement... 19:23:39 Voltage Offset Correction: v_off_ini = 501.221 uV, v_off_fin = 504.700 uV 19:23:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.281 uVs 19:23:39 Integrated Voltage Measurement... 19:23:48 Voltage Offset Correction: v_off_ini = 499.008 uV, v_off_fin = 496.888 uV 19:23:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.577 uVs 19:23:48 Integrated Voltage Measurement... 19:23:57 Voltage Offset Correction: v_off_ini = 508.984 uV, v_off_fin = 513.058 uV 19:23:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.759 uVs 19:23:57 Integrated Voltage Measurement... 19:24:06 Voltage Offset Correction: v_off_ini = 516.628 uV, v_off_fin = 496.697 uV 19:24:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.951 uVs 19:24:06 Integrated Voltage Measurement... 19:24:15 Voltage Offset Correction: v_off_ini = 507.786 uV, v_off_fin = 522.881 uV 19:24:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.189 uVs 19:24:19 I1Y Average and RMS of Measurements VT = -200.235 +- 2.839 uVs I1Y = -40.047 +- 0.568 uTm 19:24:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:24:27 Integrated Voltage Measurement... 19:24:36 Voltage Offset Correction: v_off_ini = 502.961 uV, v_off_fin = 497.187 uV 19:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.853 uVs 19:24:36 Integrated Voltage Measurement... 19:24:45 Voltage Offset Correction: v_off_ini = 496.039 uV, v_off_fin = 502.346 uV 19:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.839 uVs 19:24:45 Integrated Voltage Measurement... 19:24:54 Voltage Offset Correction: v_off_ini = 497.786 uV, v_off_fin = 489.766 uV 19:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.048 uVs 19:24:54 Integrated Voltage Measurement... 19:25:03 Voltage Offset Correction: v_off_ini = 496.261 uV, v_off_fin = 503.541 uV 19:25:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.821 uVs 19:25:03 Integrated Voltage Measurement... 19:25:12 Voltage Offset Correction: v_off_ini = 499.974 uV, v_off_fin = 495.859 uV 19:25:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.964 uVs 19:25:12 Integrated Voltage Measurement... 19:25:21 Voltage Offset Correction: v_off_ini = 500.246 uV, v_off_fin = 502.208 uV 19:25:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.617 uVs 19:25:23 I2X Average and RMS of Measurements VT = -101.357 +- 5.396 uVs I2X = 9.325 +- 0.496 uTm^2 19:25:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:25:31 Integrated Voltage Measurement... 19:25:40 Voltage Offset Correction: v_off_ini = 496.135 uV, v_off_fin = 492.725 uV 19:25:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.796 uVs 19:25:40 Integrated Voltage Measurement... 19:25:49 Voltage Offset Correction: v_off_ini = 495.172 uV, v_off_fin = 502.066 uV 19:25:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.382 uVs 19:25:49 Integrated Voltage Measurement... 19:25:58 Voltage Offset Correction: v_off_ini = 513.091 uV, v_off_fin = 490.617 uV 19:25:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -194.590 uVs 19:25:58 Integrated Voltage Measurement... 19:26:07 Voltage Offset Correction: v_off_ini = 503.607 uV, v_off_fin = 502.608 uV 19:26:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.748 uVs 19:26:07 Integrated Voltage Measurement... 19:26:16 Voltage Offset Correction: v_off_ini = 500.265 uV, v_off_fin = 493.669 uV 19:26:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.683 uVs 19:26:16 Integrated Voltage Measurement... 19:26:25 Voltage Offset Correction: v_off_ini = 492.533 uV, v_off_fin = 498.679 uV 19:26:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.873 uVs 19:26:28 I2Y Average and RMS of Measurements VT = -201.179 +- 5.407 uVs I2Y = -18.509 +- 0.498 uTm^2 19:26:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:26:36 Integrated Voltage Measurement... 19:26:45 Voltage Offset Correction: v_off_ini = 488.523 uV, v_off_fin = 484.069 uV 19:26:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.508 uVs 19:26:46 Integrated Voltage Measurement... 19:26:54 Voltage Offset Correction: v_off_ini = 497.469 uV, v_off_fin = 495.719 uV 19:26:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.731 uVs 19:26:55 Integrated Voltage Measurement... 19:27:03 Voltage Offset Correction: v_off_ini = 496.373 uV, v_off_fin = 499.746 uV 19:27:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.579 uVs 19:27:04 Integrated Voltage Measurement... 19:27:12 Voltage Offset Correction: v_off_ini = 508.946 uV, v_off_fin = 503.894 uV 19:27:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.603 uVs 19:27:13 Integrated Voltage Measurement... 19:27:22 Voltage Offset Correction: v_off_ini = 506.190 uV, v_off_fin = 511.479 uV 19:27:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.520 uVs 19:27:22 Integrated Voltage Measurement... 19:27:31 Voltage Offset Correction: v_off_ini = 506.180 uV, v_off_fin = 500.472 uV 19:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.496 uVs 19:27:35 I1X Average and RMS of Measurements VT = -91.073 +- 7.918 uVs I1X = 18.215 +- 1.584 uTm 19:27:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:27:42 Integrated Voltage Measurement... 19:27:51 Voltage Offset Correction: v_off_ini = 500.853 uV, v_off_fin = 481.837 uV 19:27:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.395 uVs 19:27:51 Integrated Voltage Measurement... 19:28:00 Voltage Offset Correction: v_off_ini = 498.196 uV, v_off_fin = 502.784 uV 19:28:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.372 uVs 19:28:00 Integrated Voltage Measurement... 19:28:08 Voltage Offset Correction: v_off_ini = 492.905 uV, v_off_fin = 490.629 uV 19:28:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.408 uVs 19:28:09 Integrated Voltage Measurement... 19:28:17 Voltage Offset Correction: v_off_ini = 484.613 uV, v_off_fin = 500.592 uV 19:28:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.567 uVs 19:28:18 Integrated Voltage Measurement... 19:28:27 Voltage Offset Correction: v_off_ini = 485.776 uV, v_off_fin = 481.946 uV 19:28:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.779 uVs 19:28:27 Integrated Voltage Measurement... 19:28:35 Voltage Offset Correction: v_off_ini = 486.702 uV, v_off_fin = 490.024 uV 19:28:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.578 uVs 19:28:40 I1Y Average and RMS of Measurements VT = -199.516 +- 5.137 uVs I1Y = -39.903 +- 1.027 uTm 19:28:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:28:47 Integrated Voltage Measurement... 19:28:56 Voltage Offset Correction: v_off_ini = 469.181 uV, v_off_fin = 477.987 uV 19:28:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -94.990 uVs 19:28:57 Integrated Voltage Measurement... 19:29:05 Voltage Offset Correction: v_off_ini = 480.331 uV, v_off_fin = 493.726 uV 19:29:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.388 uVs 19:29:06 Integrated Voltage Measurement... 19:29:15 Voltage Offset Correction: v_off_ini = 497.039 uV, v_off_fin = 492.942 uV 19:29:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.431 uVs 19:29:15 Integrated Voltage Measurement... 19:29:24 Voltage Offset Correction: v_off_ini = 494.138 uV, v_off_fin = 490.339 uV 19:29:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.011 uVs 19:29:24 Integrated Voltage Measurement... 19:29:33 Voltage Offset Correction: v_off_ini = 487.202 uV, v_off_fin = 483.558 uV 19:29:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.680 uVs 19:29:33 Integrated Voltage Measurement... 19:29:42 Voltage Offset Correction: v_off_ini = 486.844 uV, v_off_fin = 486.474 uV 19:29:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.429 uVs 19:29:44 I2X Average and RMS of Measurements VT = -91.322 +- 7.708 uVs I2X = 8.401 +- 0.709 uTm^2 19:29:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:29:52 Integrated Voltage Measurement... 19:30:01 Voltage Offset Correction: v_off_ini = 490.064 uV, v_off_fin = 493.037 uV 19:30:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.067 uVs 19:30:01 Integrated Voltage Measurement... 19:30:10 Voltage Offset Correction: v_off_ini = 489.240 uV, v_off_fin = 492.548 uV 19:30:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.549 uVs 19:30:10 Integrated Voltage Measurement... 19:30:19 Voltage Offset Correction: v_off_ini = 491.049 uV, v_off_fin = 480.644 uV 19:30:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.384 uVs 19:30:19 Integrated Voltage Measurement... 19:30:28 Voltage Offset Correction: v_off_ini = 477.488 uV, v_off_fin = 482.868 uV 19:30:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.423 uVs 19:30:28 Integrated Voltage Measurement... 19:30:37 Voltage Offset Correction: v_off_ini = 498.955 uV, v_off_fin = 486.011 uV 19:30:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.628 uVs 19:30:37 Integrated Voltage Measurement... 19:30:46 Voltage Offset Correction: v_off_ini = 487.823 uV, v_off_fin = 483.169 uV 19:30:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.952 uVs 19:30:48 I2Y Average and RMS of Measurements VT = -202.167 +- 3.739 uVs I2Y = -18.599 +- 0.344 uTm^2 19:30:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:30:57 Integrated Voltage Measurement... 19:31:06 Voltage Offset Correction: v_off_ini = 490.387 uV, v_off_fin = 490.010 uV 19:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -104.671 uVs 19:31:06 Integrated Voltage Measurement... 19:31:15 Voltage Offset Correction: v_off_ini = 485.657 uV, v_off_fin = 495.811 uV 19:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.946 uVs 19:31:15 Integrated Voltage Measurement... 19:31:24 Voltage Offset Correction: v_off_ini = 508.036 uV, v_off_fin = 496.127 uV 19:31:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.022 uVs 19:31:24 Integrated Voltage Measurement... 19:31:33 Voltage Offset Correction: v_off_ini = 497.217 uV, v_off_fin = 494.525 uV 19:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.000 uVs 19:31:33 Integrated Voltage Measurement... 19:31:42 Voltage Offset Correction: v_off_ini = 492.212 uV, v_off_fin = 484.201 uV 19:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.248 uVs 19:31:42 Integrated Voltage Measurement... 19:31:51 Voltage Offset Correction: v_off_ini = 496.790 uV, v_off_fin = 495.952 uV 19:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.403 uVs 19:31:56 I1X Average and RMS of Measurements VT = -105.715 +- 2.541 uVs I1X = 21.144 +- 0.508 uTm 19:31:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:32:02 Integrated Voltage Measurement... 19:32:11 Voltage Offset Correction: v_off_ini = 492.809 uV, v_off_fin = 480.182 uV 19:32:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.586 uVs 19:32:11 Integrated Voltage Measurement... 19:32:20 Voltage Offset Correction: v_off_ini = 483.224 uV, v_off_fin = 485.522 uV 19:32:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.430 uVs 19:32:20 Integrated Voltage Measurement... 19:32:29 Voltage Offset Correction: v_off_ini = 479.225 uV, v_off_fin = 475.302 uV 19:32:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.535 uVs 19:32:29 Integrated Voltage Measurement... 19:32:38 Voltage Offset Correction: v_off_ini = 486.214 uV, v_off_fin = 492.248 uV 19:32:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.168 uVs 19:32:38 Integrated Voltage Measurement... 19:32:47 Voltage Offset Correction: v_off_ini = 484.467 uV, v_off_fin = 484.019 uV 19:32:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.314 uVs 19:32:47 Integrated Voltage Measurement... 19:32:56 Voltage Offset Correction: v_off_ini = 490.020 uV, v_off_fin = 491.184 uV 19:32:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.260 uVs 19:33:01 I1Y Average and RMS of Measurements VT = -197.382 +- 6.677 uVs I1Y = -39.476 +- 1.335 uTm 19:33:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:33:08 Integrated Voltage Measurement... 19:33:17 Voltage Offset Correction: v_off_ini = 473.435 uV, v_off_fin = 471.248 uV 19:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.532 uVs 19:33:17 Integrated Voltage Measurement... 19:33:26 Voltage Offset Correction: v_off_ini = 483.773 uV, v_off_fin = 493.028 uV 19:33:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.035 uVs 19:33:26 Integrated Voltage Measurement... 19:33:35 Voltage Offset Correction: v_off_ini = 491.073 uV, v_off_fin = 484.789 uV 19:33:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.183 uVs 19:33:35 Integrated Voltage Measurement... 19:33:44 Voltage Offset Correction: v_off_ini = 490.706 uV, v_off_fin = 491.336 uV 19:33:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.764 uVs 19:33:44 Integrated Voltage Measurement... 19:33:53 Voltage Offset Correction: v_off_ini = 501.451 uV, v_off_fin = 482.945 uV 19:33:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.863 uVs 19:33:53 Integrated Voltage Measurement... 19:34:02 Voltage Offset Correction: v_off_ini = 489.390 uV, v_off_fin = 494.882 uV 19:34:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.952 uVs 19:34:05 I2X Average and RMS of Measurements VT = -101.555 +- 6.327 uVs I2X = 9.343 +- 0.582 uTm^2 19:34:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:34:13 Integrated Voltage Measurement... 19:34:21 Voltage Offset Correction: v_off_ini = 483.147 uV, v_off_fin = 483.771 uV 19:34:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.215 uVs 19:34:22 Integrated Voltage Measurement... 19:34:31 Voltage Offset Correction: v_off_ini = 495.946 uV, v_off_fin = 485.052 uV 19:34:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.593 uVs 19:34:31 Integrated Voltage Measurement... 19:34:40 Voltage Offset Correction: v_off_ini = 490.758 uV, v_off_fin = 480.267 uV 19:34:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.166 uVs 19:34:40 Integrated Voltage Measurement... 19:34:49 Voltage Offset Correction: v_off_ini = 481.069 uV, v_off_fin = 478.016 uV 19:34:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.299 uVs 19:34:49 Integrated Voltage Measurement... 19:34:58 Voltage Offset Correction: v_off_ini = 469.503 uV, v_off_fin = 475.276 uV 19:34:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.631 uVs 19:34:58 Integrated Voltage Measurement... 19:35:07 Voltage Offset Correction: v_off_ini = 474.331 uV, v_off_fin = 485.788 uV 19:35:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.139 uVs 19:35:09 I2Y Average and RMS of Measurements VT = -195.341 +- 11.341 uVs I2Y = -17.971 +- 1.043 uTm^2 19:35:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:35:18 Integrated Voltage Measurement... 19:35:27 Voltage Offset Correction: v_off_ini = 488.519 uV, v_off_fin = 483.814 uV 19:35:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.761 uVs 19:35:27 Integrated Voltage Measurement... 19:35:36 Voltage Offset Correction: v_off_ini = 462.591 uV, v_off_fin = 486.647 uV 19:35:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.582 uVs 19:35:36 Integrated Voltage Measurement... 19:35:45 Voltage Offset Correction: v_off_ini = 473.567 uV, v_off_fin = 477.546 uV 19:35:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.682 uVs 19:35:45 Integrated Voltage Measurement... 19:35:54 Voltage Offset Correction: v_off_ini = 472.418 uV, v_off_fin = 475.568 uV 19:35:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.136 uVs 19:35:54 Integrated Voltage Measurement... 19:36:03 Voltage Offset Correction: v_off_ini = 487.560 uV, v_off_fin = 486.589 uV 19:36:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.443 uVs 19:36:03 Integrated Voltage Measurement... 19:36:12 Voltage Offset Correction: v_off_ini = 474.265 uV, v_off_fin = 481.880 uV 19:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.046 uVs 19:36:16 I1X Average and RMS of Measurements VT = -103.942 +- 1.411 uVs I1X = 20.789 +- 0.282 uTm 19:36:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:36:23 Integrated Voltage Measurement... 19:36:32 Voltage Offset Correction: v_off_ini = 477.639 uV, v_off_fin = 462.964 uV 19:36:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.441 uVs 19:36:32 Integrated Voltage Measurement... 19:36:41 Voltage Offset Correction: v_off_ini = 487.033 uV, v_off_fin = 493.313 uV 19:36:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.650 uVs 19:36:41 Integrated Voltage Measurement... 19:36:50 Voltage Offset Correction: v_off_ini = 466.173 uV, v_off_fin = 465.675 uV 19:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.670 uVs 19:36:50 Integrated Voltage Measurement... 19:36:59 Voltage Offset Correction: v_off_ini = 482.511 uV, v_off_fin = 485.529 uV 19:36:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.905 uVs 19:36:59 Integrated Voltage Measurement... 19:37:08 Voltage Offset Correction: v_off_ini = 476.914 uV, v_off_fin = 474.798 uV 19:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.440 uVs 19:37:08 Integrated Voltage Measurement... 19:37:17 Voltage Offset Correction: v_off_ini = 481.734 uV, v_off_fin = 478.895 uV 19:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.776 uVs 19:37:21 I1Y Average and RMS of Measurements VT = -196.647 +- 2.190 uVs I1Y = -39.329 +- 0.438 uTm 19:37:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:37:29 Integrated Voltage Measurement... 19:37:38 Voltage Offset Correction: v_off_ini = 463.013 uV, v_off_fin = 459.997 uV 19:37:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.193 uVs 19:37:38 Integrated Voltage Measurement... 19:37:47 Voltage Offset Correction: v_off_ini = 479.502 uV, v_off_fin = 475.948 uV 19:37:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.723 uVs 19:37:47 Integrated Voltage Measurement... 19:37:56 Voltage Offset Correction: v_off_ini = 461.433 uV, v_off_fin = 459.358 uV 19:37:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.718 uVs 19:37:56 Integrated Voltage Measurement... 19:38:05 Voltage Offset Correction: v_off_ini = 479.000 uV, v_off_fin = 480.371 uV 19:38:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.648 uVs 19:38:05 Integrated Voltage Measurement... 19:38:14 Voltage Offset Correction: v_off_ini = 484.319 uV, v_off_fin = 485.626 uV 19:38:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.863 uVs 19:38:14 Integrated Voltage Measurement... 19:38:23 Voltage Offset Correction: v_off_ini = 488.322 uV, v_off_fin = 488.804 uV 19:38:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.681 uVs 19:38:25 I2X Average and RMS of Measurements VT = -100.304 +- 4.251 uVs I2X = 9.228 +- 0.391 uTm^2 19:38:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:38:33 Integrated Voltage Measurement... 19:38:42 Voltage Offset Correction: v_off_ini = 487.132 uV, v_off_fin = 481.148 uV 19:38:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.357 uVs 19:38:42 Integrated Voltage Measurement... 19:38:51 Voltage Offset Correction: v_off_ini = 497.215 uV, v_off_fin = 491.199 uV 19:38:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.186 uVs 19:38:51 Integrated Voltage Measurement... 19:39:00 Voltage Offset Correction: v_off_ini = 489.294 uV, v_off_fin = 492.368 uV 19:39:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.248 uVs 19:39:00 Integrated Voltage Measurement... 19:39:09 Voltage Offset Correction: v_off_ini = 487.117 uV, v_off_fin = 484.252 uV 19:39:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.563 uVs 19:39:09 Integrated Voltage Measurement... 19:39:18 Voltage Offset Correction: v_off_ini = 486.510 uV, v_off_fin = 492.286 uV 19:39:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.239 uVs 19:39:18 Integrated Voltage Measurement... 19:39:27 Voltage Offset Correction: v_off_ini = 489.102 uV, v_off_fin = 483.058 uV 19:39:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.414 uVs 19:39:29 I2Y Average and RMS of Measurements VT = -195.168 +- 5.230 uVs I2Y = -17.956 +- 0.481 uTm^2 19:39:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:39:41 Integrated Voltage Measurement... 19:39:50 Voltage Offset Correction: v_off_ini = 490.909 uV, v_off_fin = 470.941 uV 19:39:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.387 uVs 19:39:50 Integrated Voltage Measurement... 19:39:59 Voltage Offset Correction: v_off_ini = 490.752 uV, v_off_fin = 471.792 uV 19:39:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.034 uVs 19:39:59 Integrated Voltage Measurement... 19:40:08 Voltage Offset Correction: v_off_ini = 483.682 uV, v_off_fin = 477.425 uV 19:40:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.265 uVs 19:40:08 Integrated Voltage Measurement... 19:40:17 Voltage Offset Correction: v_off_ini = 485.613 uV, v_off_fin = 453.484 uV 19:40:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.702 uVs 19:40:17 Integrated Voltage Measurement... 19:40:26 Voltage Offset Correction: v_off_ini = 475.623 uV, v_off_fin = 468.330 uV 19:40:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.084 uVs 19:40:26 Integrated Voltage Measurement... 19:40:35 Voltage Offset Correction: v_off_ini = 459.484 uV, v_off_fin = 474.185 uV 19:40:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.804 uVs 19:40:40 I1X Average and RMS of Measurements VT = -90.213 +- 3.209 uVs I1X = 18.043 +- 0.642 uTm 19:40:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:40:46 Integrated Voltage Measurement... 19:40:55 Voltage Offset Correction: v_off_ini = 462.366 uV, v_off_fin = 455.283 uV 19:40:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.632 uVs 19:40:55 Integrated Voltage Measurement... 19:41:04 Voltage Offset Correction: v_off_ini = 459.333 uV, v_off_fin = 468.663 uV 19:41:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.994 uVs 19:41:04 Integrated Voltage Measurement... 19:41:13 Voltage Offset Correction: v_off_ini = 459.186 uV, v_off_fin = 444.738 uV 19:41:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.076 uVs 19:41:13 Integrated Voltage Measurement... 19:41:22 Voltage Offset Correction: v_off_ini = 458.282 uV, v_off_fin = 470.515 uV 19:41:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.505 uVs 19:41:22 Integrated Voltage Measurement... 19:41:31 Voltage Offset Correction: v_off_ini = 454.864 uV, v_off_fin = 449.566 uV 19:41:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.334 uVs 19:41:31 Integrated Voltage Measurement... 19:41:40 Voltage Offset Correction: v_off_ini = 452.557 uV, v_off_fin = 465.653 uV 19:41:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.292 uVs 19:41:45 I1Y Average and RMS of Measurements VT = -200.472 +- 9.100 uVs I1Y = -40.094 +- 1.820 uTm 19:41:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:41:50 Integrated Voltage Measurement... 19:41:59 Voltage Offset Correction: v_off_ini = 456.089 uV, v_off_fin = 437.238 uV 19:41:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.706 uVs 19:41:59 Integrated Voltage Measurement... 19:42:08 Voltage Offset Correction: v_off_ini = 441.237 uV, v_off_fin = 434.753 uV 19:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.730 uVs 19:42:08 Integrated Voltage Measurement... 19:42:17 Voltage Offset Correction: v_off_ini = 431.226 uV, v_off_fin = 435.595 uV 19:42:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.847 uVs 19:42:17 Integrated Voltage Measurement... 19:42:26 Voltage Offset Correction: v_off_ini = 453.632 uV, v_off_fin = 445.730 uV 19:42:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.199 uVs 19:42:26 Integrated Voltage Measurement... 19:42:35 Voltage Offset Correction: v_off_ini = 441.927 uV, v_off_fin = 432.383 uV 19:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.965 uVs 19:42:35 Integrated Voltage Measurement... 19:42:44 Voltage Offset Correction: v_off_ini = 440.940 uV, v_off_fin = 445.202 uV 19:42:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.857 uVs 19:42:46 I2X Average and RMS of Measurements VT = -80.384 +- 4.500 uVs I2X = 7.395 +- 0.414 uTm^2 19:42:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:42:51 Integrated Voltage Measurement... 19:43:00 Voltage Offset Correction: v_off_ini = 450.688 uV, v_off_fin = 442.378 uV 19:43:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.537 uVs 19:43:00 Integrated Voltage Measurement... 19:43:09 Voltage Offset Correction: v_off_ini = 440.304 uV, v_off_fin = 448.614 uV 19:43:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.913 uVs 19:43:09 Integrated Voltage Measurement... 19:43:18 Voltage Offset Correction: v_off_ini = 443.082 uV, v_off_fin = 440.314 uV 19:43:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.408 uVs 19:43:18 Integrated Voltage Measurement... 19:43:27 Voltage Offset Correction: v_off_ini = 443.636 uV, v_off_fin = 447.160 uV 19:43:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.962 uVs 19:43:27 Integrated Voltage Measurement... 19:43:36 Voltage Offset Correction: v_off_ini = 436.174 uV, v_off_fin = 445.646 uV 19:43:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.461 uVs 19:43:36 Integrated Voltage Measurement... 19:43:45 Voltage Offset Correction: v_off_ini = 451.638 uV, v_off_fin = 445.803 uV 19:43:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.179 uVs 19:43:48 I2Y Average and RMS of Measurements VT = -197.910 +- 0.595 uVs I2Y = -18.208 +- 0.055 uTm^2 19:43:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:43:56 Integrated Voltage Measurement... 19:44:05 Voltage Offset Correction: v_off_ini = 461.125 uV, v_off_fin = 455.575 uV 19:44:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.410 uVs 19:44:05 Integrated Voltage Measurement... 19:44:14 Voltage Offset Correction: v_off_ini = 451.493 uV, v_off_fin = 460.679 uV 19:44:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.968 uVs 19:44:14 Integrated Voltage Measurement... 19:44:23 Voltage Offset Correction: v_off_ini = 466.134 uV, v_off_fin = 462.605 uV 19:44:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.277 uVs 19:44:23 Integrated Voltage Measurement... 19:44:32 Voltage Offset Correction: v_off_ini = 473.002 uV, v_off_fin = 471.895 uV 19:44:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.908 uVs 19:44:32 Integrated Voltage Measurement... 19:44:41 Voltage Offset Correction: v_off_ini = 476.950 uV, v_off_fin = 477.319 uV 19:44:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.808 uVs 19:44:41 Integrated Voltage Measurement... 19:44:50 Voltage Offset Correction: v_off_ini = 470.326 uV, v_off_fin = 469.005 uV 19:44:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.407 uVs 19:44:54 I1X Average and RMS of Measurements VT = -82.963 +- 1.850 uVs I1X = 16.593 +- 0.370 uTm 19:44:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:45:01 Integrated Voltage Measurement... 19:45:10 Voltage Offset Correction: v_off_ini = 457.442 uV, v_off_fin = 464.264 uV 19:45:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.946 uVs 19:45:10 Integrated Voltage Measurement... 19:45:19 Voltage Offset Correction: v_off_ini = 471.954 uV, v_off_fin = 476.852 uV 19:45:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.839 uVs 19:45:19 Integrated Voltage Measurement... 19:45:28 Voltage Offset Correction: v_off_ini = 468.243 uV, v_off_fin = 454.320 uV 19:45:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.593 uVs 19:45:28 Integrated Voltage Measurement... 19:45:37 Voltage Offset Correction: v_off_ini = 460.303 uV, v_off_fin = 465.255 uV 19:45:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.063 uVs 19:45:37 Integrated Voltage Measurement... 19:45:46 Voltage Offset Correction: v_off_ini = 465.837 uV, v_off_fin = 458.645 uV 19:45:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.280 uVs 19:45:46 Integrated Voltage Measurement... 19:45:55 Voltage Offset Correction: v_off_ini = 461.105 uV, v_off_fin = 483.074 uV 19:45:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.293 uVs 19:45:59 I1Y Average and RMS of Measurements VT = -200.836 +- 2.815 uVs I1Y = -40.167 +- 0.563 uTm 19:46:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:46:04 Integrated Voltage Measurement... 19:46:13 Voltage Offset Correction: v_off_ini = 458.165 uV, v_off_fin = 455.495 uV 19:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.182 uVs 19:46:13 Integrated Voltage Measurement... 19:46:22 Voltage Offset Correction: v_off_ini = 472.234 uV, v_off_fin = 463.667 uV 19:46:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.815 uVs 19:46:22 Integrated Voltage Measurement... 19:46:31 Voltage Offset Correction: v_off_ini = 449.511 uV, v_off_fin = 455.581 uV 19:46:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.253 uVs 19:46:31 Integrated Voltage Measurement... 19:46:40 Voltage Offset Correction: v_off_ini = 465.418 uV, v_off_fin = 474.053 uV 19:46:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.217 uVs 19:46:40 Integrated Voltage Measurement... 19:46:49 Voltage Offset Correction: v_off_ini = 470.195 uV, v_off_fin = 463.556 uV 19:46:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.018 uVs 19:46:49 Integrated Voltage Measurement... 19:46:58 Voltage Offset Correction: v_off_ini = 461.354 uV, v_off_fin = 470.879 uV 19:46:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.368 uVs 19:47:01 I2X Average and RMS of Measurements VT = -88.976 +- 2.187 uVs I2X = 8.186 +- 0.201 uTm^2 19:47:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:47:06 Integrated Voltage Measurement... 19:47:15 Voltage Offset Correction: v_off_ini = 468.763 uV, v_off_fin = 469.321 uV 19:47:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -191.331 uVs 19:47:15 Integrated Voltage Measurement... 19:47:24 Voltage Offset Correction: v_off_ini = 469.837 uV, v_off_fin = 468.379 uV 19:47:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.567 uVs 19:47:24 Integrated Voltage Measurement... 19:47:33 Voltage Offset Correction: v_off_ini = 472.048 uV, v_off_fin = 466.961 uV 19:47:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.815 uVs 19:47:33 Integrated Voltage Measurement... 19:47:42 Voltage Offset Correction: v_off_ini = 470.472 uV, v_off_fin = 479.010 uV 19:47:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.059 uVs 19:47:42 Integrated Voltage Measurement... 19:47:51 Voltage Offset Correction: v_off_ini = 471.260 uV, v_off_fin = 475.808 uV 19:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.253 uVs 19:47:51 Integrated Voltage Measurement... 19:48:00 Voltage Offset Correction: v_off_ini = 482.404 uV, v_off_fin = 479.073 uV 19:48:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.035 uVs 19:48:02 I2Y Average and RMS of Measurements VT = -194.510 +- 4.909 uVs I2Y = -17.895 +- 0.451 uTm^2 19:48:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:48:11 Integrated Voltage Measurement... 19:48:20 Voltage Offset Correction: v_off_ini = 477.819 uV, v_off_fin = 469.297 uV 19:48:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.499 uVs 19:48:20 Integrated Voltage Measurement... 19:48:29 Voltage Offset Correction: v_off_ini = 481.643 uV, v_off_fin = 479.438 uV 19:48:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.427 uVs 19:48:29 Integrated Voltage Measurement... 19:48:38 Voltage Offset Correction: v_off_ini = 477.808 uV, v_off_fin = 491.840 uV 19:48:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.331 uVs 19:48:38 Integrated Voltage Measurement... 19:48:47 Voltage Offset Correction: v_off_ini = 480.004 uV, v_off_fin = 491.320 uV 19:48:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.433 uVs 19:48:47 Integrated Voltage Measurement... 19:48:56 Voltage Offset Correction: v_off_ini = 482.340 uV, v_off_fin = 481.182 uV 19:48:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.761 uVs 19:48:56 Integrated Voltage Measurement... 19:49:05 Voltage Offset Correction: v_off_ini = 480.193 uV, v_off_fin = 485.392 uV 19:49:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.796 uVs 19:49:09 I1X Average and RMS of Measurements VT = -88.541 +- 6.689 uVs I1X = 17.709 +- 1.337 uTm 19:49:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:49:16 Integrated Voltage Measurement... 19:49:25 Voltage Offset Correction: v_off_ini = 485.492 uV, v_off_fin = 475.847 uV 19:49:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.449 uVs 19:49:25 Integrated Voltage Measurement... 19:49:34 Voltage Offset Correction: v_off_ini = 483.440 uV, v_off_fin = 493.090 uV 19:49:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.644 uVs 19:49:34 Integrated Voltage Measurement... 19:49:43 Voltage Offset Correction: v_off_ini = 495.340 uV, v_off_fin = 470.871 uV 19:49:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.439 uVs 19:49:43 Integrated Voltage Measurement... 19:49:52 Voltage Offset Correction: v_off_ini = 477.585 uV, v_off_fin = 490.109 uV 19:49:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.600 uVs 19:49:52 Integrated Voltage Measurement... 19:50:01 Voltage Offset Correction: v_off_ini = 479.654 uV, v_off_fin = 467.660 uV 19:50:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.446 uVs 19:50:01 Integrated Voltage Measurement... 19:50:10 Voltage Offset Correction: v_off_ini = 467.928 uV, v_off_fin = 485.721 uV 19:50:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.207 uVs 19:50:14 I1Y Average and RMS of Measurements VT = -197.797 +- 8.692 uVs I1Y = -39.559 +- 1.738 uTm 19:50:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:50:19 Integrated Voltage Measurement... 19:50:28 Voltage Offset Correction: v_off_ini = 470.581 uV, v_off_fin = 483.928 uV 19:50:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.673 uVs 19:50:28 Integrated Voltage Measurement... 19:50:37 Voltage Offset Correction: v_off_ini = 485.831 uV, v_off_fin = 494.075 uV 19:50:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.266 uVs 19:50:37 Integrated Voltage Measurement... 19:50:46 Voltage Offset Correction: v_off_ini = 488.829 uV, v_off_fin = 467.039 uV 19:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.863 uVs 19:50:46 Integrated Voltage Measurement... 19:50:55 Voltage Offset Correction: v_off_ini = 487.160 uV, v_off_fin = 496.968 uV 19:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.150 uVs 19:50:55 Integrated Voltage Measurement... 19:51:04 Voltage Offset Correction: v_off_ini = 476.637 uV, v_off_fin = 467.565 uV 19:51:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.227 uVs 19:51:04 Integrated Voltage Measurement... 19:51:13 Voltage Offset Correction: v_off_ini = 489.066 uV, v_off_fin = 486.892 uV 19:51:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.227 uVs 19:51:16 I2X Average and RMS of Measurements VT = -88.568 +- 2.273 uVs I2X = 8.148 +- 0.209 uTm^2 19:51:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:51:21 Integrated Voltage Measurement... 19:51:30 Voltage Offset Correction: v_off_ini = 475.256 uV, v_off_fin = 486.666 uV 19:51:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.791 uVs 19:51:30 Integrated Voltage Measurement... 19:51:39 Voltage Offset Correction: v_off_ini = 488.435 uV, v_off_fin = 485.067 uV 19:51:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.843 uVs 19:51:39 Integrated Voltage Measurement... 19:51:48 Voltage Offset Correction: v_off_ini = 484.120 uV, v_off_fin = 479.715 uV 19:51:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.695 uVs 19:51:48 Integrated Voltage Measurement... 19:51:57 Voltage Offset Correction: v_off_ini = 483.535 uV, v_off_fin = 487.041 uV 19:51:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.962 uVs 19:51:57 Integrated Voltage Measurement... 19:52:06 Voltage Offset Correction: v_off_ini = 483.623 uV, v_off_fin = 473.244 uV 19:52:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.834 uVs 19:52:06 Integrated Voltage Measurement... 19:52:15 Voltage Offset Correction: v_off_ini = 480.960 uV, v_off_fin = 479.974 uV 19:52:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.354 uVs 19:52:17 I2Y Average and RMS of Measurements VT = -205.080 +- 6.837 uVs I2Y = -18.868 +- 0.629 uTm^2 19:52:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:52:26 Integrated Voltage Measurement... 19:52:35 Voltage Offset Correction: v_off_ini = 483.056 uV, v_off_fin = 482.093 uV 19:52:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.743 uVs 19:52:35 Integrated Voltage Measurement... 19:52:44 Voltage Offset Correction: v_off_ini = 473.444 uV, v_off_fin = 478.287 uV 19:52:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.569 uVs 19:52:44 Integrated Voltage Measurement... 19:52:53 Voltage Offset Correction: v_off_ini = 477.116 uV, v_off_fin = 484.410 uV 19:52:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.351 uVs 19:52:53 Integrated Voltage Measurement... 19:53:02 Voltage Offset Correction: v_off_ini = 490.446 uV, v_off_fin = 491.934 uV 19:53:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.868 uVs 19:53:02 Integrated Voltage Measurement... 19:53:11 Voltage Offset Correction: v_off_ini = 489.885 uV, v_off_fin = 480.112 uV 19:53:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.740 uVs 19:53:11 Integrated Voltage Measurement... 19:53:20 Voltage Offset Correction: v_off_ini = 490.889 uV, v_off_fin = 488.066 uV 19:53:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.193 uVs 19:53:24 I1X Average and RMS of Measurements VT = -94.411 +- 10.729 uVs I1X = 18.882 +- 2.146 uTm 19:53:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:53:31 Integrated Voltage Measurement... 19:53:40 Voltage Offset Correction: v_off_ini = 481.969 uV, v_off_fin = 466.257 uV 19:53:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.559 uVs 19:53:40 Integrated Voltage Measurement... 19:53:49 Voltage Offset Correction: v_off_ini = 486.432 uV, v_off_fin = 490.624 uV 19:53:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.056 uVs 19:53:49 Integrated Voltage Measurement... 19:53:58 Voltage Offset Correction: v_off_ini = 487.680 uV, v_off_fin = 476.203 uV 19:53:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.499 uVs 19:53:58 Integrated Voltage Measurement... 19:54:07 Voltage Offset Correction: v_off_ini = 487.131 uV, v_off_fin = 493.873 uV 19:54:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.772 uVs 19:54:07 Integrated Voltage Measurement... 19:54:16 Voltage Offset Correction: v_off_ini = 487.607 uV, v_off_fin = 473.166 uV 19:54:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.758 uVs 19:54:16 Integrated Voltage Measurement... 19:54:25 Voltage Offset Correction: v_off_ini = 490.123 uV, v_off_fin = 494.691 uV 19:54:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.656 uVs 19:54:29 I1Y Average and RMS of Measurements VT = -197.384 +- 4.076 uVs I1Y = -39.474 +- 0.814 uTm 19:54:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:54:34 Integrated Voltage Measurement... 19:54:43 Voltage Offset Correction: v_off_ini = 462.688 uV, v_off_fin = 473.338 uV 19:54:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.211 uVs 19:54:43 Integrated Voltage Measurement... 19:54:52 Voltage Offset Correction: v_off_ini = 472.098 uV, v_off_fin = 481.411 uV 19:54:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.331 uVs 19:54:52 Integrated Voltage Measurement... 19:55:01 Voltage Offset Correction: v_off_ini = 468.632 uV, v_off_fin = 470.505 uV 19:55:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.886 uVs 19:55:01 Integrated Voltage Measurement... 19:55:10 Voltage Offset Correction: v_off_ini = 460.925 uV, v_off_fin = 477.588 uV 19:55:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.837 uVs 19:55:10 Integrated Voltage Measurement... 19:55:19 Voltage Offset Correction: v_off_ini = 457.226 uV, v_off_fin = 442.803 uV 19:55:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.710 uVs 19:55:19 Integrated Voltage Measurement... 19:55:28 Voltage Offset Correction: v_off_ini = 442.116 uV, v_off_fin = 451.637 uV 19:55:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.048 uVs 19:55:31 I2X Average and RMS of Measurements VT = -98.671 +- 4.741 uVs I2X = 9.078 +- 0.436 uTm^2 19:55:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:55:36 Integrated Voltage Measurement... 19:55:45 Voltage Offset Correction: v_off_ini = 455.615 uV, v_off_fin = 454.307 uV 19:55:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.404 uVs 19:55:45 Integrated Voltage Measurement... 19:55:54 Voltage Offset Correction: v_off_ini = 450.732 uV, v_off_fin = 448.949 uV 19:55:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.107 uVs 19:55:54 Integrated Voltage Measurement... 19:56:03 Voltage Offset Correction: v_off_ini = 442.475 uV, v_off_fin = 440.740 uV 19:56:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.135 uVs 19:56:03 Integrated Voltage Measurement... 19:56:12 Voltage Offset Correction: v_off_ini = 439.120 uV, v_off_fin = 433.152 uV 19:56:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.438 uVs 19:56:12 Integrated Voltage Measurement... 19:56:21 Voltage Offset Correction: v_off_ini = 430.999 uV, v_off_fin = 440.275 uV 19:56:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.472 uVs 19:56:21 Integrated Voltage Measurement... 19:56:30 Voltage Offset Correction: v_off_ini = 434.548 uV, v_off_fin = 441.314 uV 19:56:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.526 uVs 19:56:32 I2Y Average and RMS of Measurements VT = -202.180 +- 6.964 uVs I2Y = -18.601 +- 0.641 uTm^2 19:56:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:56:41 Integrated Voltage Measurement... 19:56:50 Voltage Offset Correction: v_off_ini = 435.003 uV, v_off_fin = 441.985 uV 19:56:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.370 uVs 19:56:50 Integrated Voltage Measurement... 19:56:59 Voltage Offset Correction: v_off_ini = 438.644 uV, v_off_fin = 435.384 uV 19:56:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.993 uVs 19:56:59 Integrated Voltage Measurement... 19:57:08 Voltage Offset Correction: v_off_ini = 427.881 uV, v_off_fin = 426.712 uV 19:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.768 uVs 19:57:08 Integrated Voltage Measurement... 19:57:17 Voltage Offset Correction: v_off_ini = 431.501 uV, v_off_fin = 438.742 uV 19:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.514 uVs 19:57:17 Integrated Voltage Measurement... 19:57:26 Voltage Offset Correction: v_off_ini = 426.050 uV, v_off_fin = 423.857 uV 19:57:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.674 uVs 19:57:26 Integrated Voltage Measurement... 19:57:35 Voltage Offset Correction: v_off_ini = 421.321 uV, v_off_fin = 428.326 uV 19:57:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.192 uVs 19:57:39 I1X Average and RMS of Measurements VT = -83.918 +- 11.527 uVs I1X = 16.784 +- 2.306 uTm 19:57:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:57:46 Integrated Voltage Measurement... 19:57:55 Voltage Offset Correction: v_off_ini = 420.904 uV, v_off_fin = 421.077 uV 19:57:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.311 uVs 19:57:55 Integrated Voltage Measurement... 19:58:04 Voltage Offset Correction: v_off_ini = 425.762 uV, v_off_fin = 436.364 uV 19:58:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 187.382 uVs 19:58:04 Integrated Voltage Measurement... 19:58:13 Voltage Offset Correction: v_off_ini = 406.362 uV, v_off_fin = 408.647 uV 19:58:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.678 uVs 19:58:13 Integrated Voltage Measurement... 19:58:22 Voltage Offset Correction: v_off_ini = 422.730 uV, v_off_fin = 441.976 uV 19:58:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.311 uVs 19:58:22 Integrated Voltage Measurement... 19:58:31 Voltage Offset Correction: v_off_ini = 420.432 uV, v_off_fin = 417.386 uV 19:58:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.865 uVs 19:58:31 Integrated Voltage Measurement... 19:58:40 Voltage Offset Correction: v_off_ini = 421.976 uV, v_off_fin = 440.427 uV 19:58:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.794 uVs 19:58:44 I1Y Average and RMS of Measurements VT = -194.557 +- 5.314 uVs I1Y = -38.910 +- 1.061 uTm 19:58:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:58:49 Integrated Voltage Measurement... 19:58:58 Voltage Offset Correction: v_off_ini = 415.472 uV, v_off_fin = 409.018 uV 19:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.760 uVs 19:58:58 Integrated Voltage Measurement... 19:59:07 Voltage Offset Correction: v_off_ini = 414.340 uV, v_off_fin = 430.227 uV 19:59:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.631 uVs 19:59:07 Integrated Voltage Measurement... 19:59:16 Voltage Offset Correction: v_off_ini = 430.344 uV, v_off_fin = 410.745 uV 19:59:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.805 uVs 19:59:16 Integrated Voltage Measurement... 19:59:25 Voltage Offset Correction: v_off_ini = 418.228 uV, v_off_fin = 424.515 uV 19:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.845 uVs 19:59:25 Integrated Voltage Measurement... 19:59:34 Voltage Offset Correction: v_off_ini = 426.930 uV, v_off_fin = 417.054 uV 19:59:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.377 uVs 19:59:34 Integrated Voltage Measurement... 19:59:43 Voltage Offset Correction: v_off_ini = 414.035 uV, v_off_fin = 420.972 uV 19:59:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.590 uVs 19:59:46 I2X Average and RMS of Measurements VT = -93.168 +- 6.473 uVs I2X = 8.571 +- 0.596 uTm^2 19:59:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:59:51 Integrated Voltage Measurement... 20:00:00 Voltage Offset Correction: v_off_ini = 431.077 uV, v_off_fin = 422.338 uV 20:00:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.980 uVs 20:00:00 Integrated Voltage Measurement... 20:00:09 Voltage Offset Correction: v_off_ini = 420.256 uV, v_off_fin = 426.757 uV 20:00:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.678 uVs 20:00:09 Integrated Voltage Measurement... 20:00:18 Voltage Offset Correction: v_off_ini = 434.171 uV, v_off_fin = 427.387 uV 20:00:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.906 uVs 20:00:18 Integrated Voltage Measurement... 20:00:27 Voltage Offset Correction: v_off_ini = 429.391 uV, v_off_fin = 428.517 uV 20:00:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.208 uVs 20:00:27 Integrated Voltage Measurement... 20:00:36 Voltage Offset Correction: v_off_ini = 440.644 uV, v_off_fin = 427.411 uV 20:00:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.589 uVs 20:00:36 Integrated Voltage Measurement... 20:00:45 Voltage Offset Correction: v_off_ini = 430.935 uV, v_off_fin = 428.511 uV 20:00:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.284 uVs 20:00:47 I2Y Average and RMS of Measurements VT = -202.608 +- 1.120 uVs I2Y = -18.640 +- 0.103 uTm^2 20:01:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:01:23 Integrated Voltage Measurement... 20:01:32 Voltage Offset Correction: v_off_ini = 418.008 uV, v_off_fin = 425.990 uV 20:01:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.772 uVs 20:01:32 Integrated Voltage Measurement... 20:01:41 Voltage Offset Correction: v_off_ini = 425.696 uV, v_off_fin = 427.443 uV 20:01:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.063 uVs 20:01:41 Integrated Voltage Measurement... 20:01:50 Voltage Offset Correction: v_off_ini = 427.975 uV, v_off_fin = 419.027 uV 20:01:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.262 uVs 20:01:50 Integrated Voltage Measurement... 20:01:59 Voltage Offset Correction: v_off_ini = 422.407 uV, v_off_fin = 429.023 uV 20:01:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.489 uVs 20:01:59 Integrated Voltage Measurement... 20:02:08 Voltage Offset Correction: v_off_ini = 421.197 uV, v_off_fin = 422.936 uV 20:02:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.663 uVs 20:02:08 Integrated Voltage Measurement... 20:02:17 Voltage Offset Correction: v_off_ini = 435.572 uV, v_off_fin = 420.492 uV 20:02:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.270 uVs 20:02:21 I1X Average and RMS of Measurements VT = -148.920 +- 8.498 uVs I1X = 29.784 +- 1.700 uTm 20:02:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:02:28 Integrated Voltage Measurement... 20:02:37 Voltage Offset Correction: v_off_ini = 437.959 uV, v_off_fin = 428.696 uV 20:02:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.358 uVs 20:02:37 Integrated Voltage Measurement... 20:02:46 Voltage Offset Correction: v_off_ini = 435.432 uV, v_off_fin = 453.955 uV 20:02:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 226.371 uVs 20:02:46 Integrated Voltage Measurement... 20:02:55 Voltage Offset Correction: v_off_ini = 431.169 uV, v_off_fin = 428.544 uV 20:02:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.577 uVs 20:02:55 Integrated Voltage Measurement... 20:03:04 Voltage Offset Correction: v_off_ini = 451.343 uV, v_off_fin = 450.392 uV 20:03:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.417 uVs 20:03:04 Integrated Voltage Measurement... 20:03:13 Voltage Offset Correction: v_off_ini = 438.791 uV, v_off_fin = 437.024 uV 20:03:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.879 uVs 20:03:13 Integrated Voltage Measurement... 20:03:22 Voltage Offset Correction: v_off_ini = 439.597 uV, v_off_fin = 463.238 uV 20:03:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.587 uVs 20:03:26 I1Y Average and RMS of Measurements VT = -229.032 +- 9.356 uVs I1Y = -45.807 +- 1.871 uTm 20:03:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:03:34 Integrated Voltage Measurement... 20:03:43 Voltage Offset Correction: v_off_ini = 445.583 uV, v_off_fin = 445.587 uV 20:03:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.703 uVs 20:03:43 Integrated Voltage Measurement... 20:03:52 Voltage Offset Correction: v_off_ini = 440.240 uV, v_off_fin = 447.522 uV 20:03:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.437 uVs 20:03:52 Integrated Voltage Measurement... 20:04:01 Voltage Offset Correction: v_off_ini = 442.162 uV, v_off_fin = 437.232 uV 20:04:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.743 uVs 20:04:01 Integrated Voltage Measurement... 20:04:10 Voltage Offset Correction: v_off_ini = 447.880 uV, v_off_fin = 452.565 uV 20:04:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.844 uVs 20:04:10 Integrated Voltage Measurement... 20:04:19 Voltage Offset Correction: v_off_ini = 443.194 uV, v_off_fin = 439.016 uV 20:04:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.078 uVs 20:04:19 Integrated Voltage Measurement... 20:04:28 Voltage Offset Correction: v_off_ini = 460.981 uV, v_off_fin = 455.812 uV 20:04:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.138 uVs 20:04:31 I2X Average and RMS of Measurements VT = -147.491 +- 3.303 uVs I2X = 13.569 +- 0.304 uTm^2 20:04:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:04:38 Integrated Voltage Measurement... 20:04:47 Voltage Offset Correction: v_off_ini = 445.054 uV, v_off_fin = 432.294 uV 20:04:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.278 uVs 20:04:47 Integrated Voltage Measurement... 20:04:56 Voltage Offset Correction: v_off_ini = 433.248 uV, v_off_fin = 439.299 uV 20:04:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.898 uVs 20:04:56 Integrated Voltage Measurement... 20:05:05 Voltage Offset Correction: v_off_ini = 447.795 uV, v_off_fin = 446.181 uV 20:05:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.949 uVs 20:05:06 Integrated Voltage Measurement... 20:05:14 Voltage Offset Correction: v_off_ini = 446.457 uV, v_off_fin = 445.562 uV 20:05:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.458 uVs 20:05:15 Integrated Voltage Measurement... 20:05:24 Voltage Offset Correction: v_off_ini = 444.728 uV, v_off_fin = 444.623 uV 20:05:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.941 uVs 20:05:24 Integrated Voltage Measurement... 20:05:33 Voltage Offset Correction: v_off_ini = 451.766 uV, v_off_fin = 443.321 uV 20:05:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.513 uVs 20:05:35 I2Y Average and RMS of Measurements VT = -232.673 +- 6.054 uVs I2Y = -21.406 +- 0.557 uTm^2 20:05:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:05:44 Integrated Voltage Measurement... 20:05:53 Voltage Offset Correction: v_off_ini = 434.989 uV, v_off_fin = 420.511 uV 20:05:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.005 uVs 20:05:53 Integrated Voltage Measurement... 20:06:02 Voltage Offset Correction: v_off_ini = 433.791 uV, v_off_fin = 432.914 uV 20:06:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.073 uVs 20:06:02 Integrated Voltage Measurement... 20:06:11 Voltage Offset Correction: v_off_ini = 415.119 uV, v_off_fin = 420.353 uV 20:06:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.220 uVs 20:06:11 Integrated Voltage Measurement... 20:06:20 Voltage Offset Correction: v_off_ini = 433.398 uV, v_off_fin = 430.649 uV 20:06:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.813 uVs 20:06:20 Integrated Voltage Measurement... 20:06:29 Voltage Offset Correction: v_off_ini = 422.698 uV, v_off_fin = 428.500 uV 20:06:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.519 uVs 20:06:29 Integrated Voltage Measurement... 20:06:38 Voltage Offset Correction: v_off_ini = 438.968 uV, v_off_fin = 437.373 uV 20:06:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.628 uVs 20:06:42 I1X Average and RMS of Measurements VT = -143.376 +- 14.143 uVs I1X = 28.675 +- 2.829 uTm 20:06:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:06:49 Integrated Voltage Measurement... 20:06:58 Voltage Offset Correction: v_off_ini = 444.828 uV, v_off_fin = 435.359 uV 20:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.552 uVs 20:06:58 Integrated Voltage Measurement... 20:07:07 Voltage Offset Correction: v_off_ini = 445.538 uV, v_off_fin = 466.412 uV 20:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.246 uVs 20:07:07 Integrated Voltage Measurement... 20:07:16 Voltage Offset Correction: v_off_ini = 452.314 uV, v_off_fin = 445.974 uV 20:07:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.728 uVs 20:07:16 Integrated Voltage Measurement... 20:07:25 Voltage Offset Correction: v_off_ini = 457.252 uV, v_off_fin = 460.659 uV 20:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.488 uVs 20:07:25 Integrated Voltage Measurement... 20:07:34 Voltage Offset Correction: v_off_ini = 456.999 uV, v_off_fin = 444.209 uV 20:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.665 uVs 20:07:34 Integrated Voltage Measurement... 20:07:43 Voltage Offset Correction: v_off_ini = 454.468 uV, v_off_fin = 467.654 uV 20:07:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.660 uVs 20:07:47 I1Y Average and RMS of Measurements VT = -224.723 +- 6.711 uVs I1Y = -44.945 +- 1.342 uTm 20:07:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:07:55 Integrated Voltage Measurement... 20:08:04 Voltage Offset Correction: v_off_ini = 441.856 uV, v_off_fin = 435.968 uV 20:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.466 uVs 20:08:04 Integrated Voltage Measurement... 20:08:13 Voltage Offset Correction: v_off_ini = 447.384 uV, v_off_fin = 454.364 uV 20:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.207 uVs 20:08:13 Integrated Voltage Measurement... 20:08:22 Voltage Offset Correction: v_off_ini = 442.715 uV, v_off_fin = 439.418 uV 20:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.356 uVs 20:08:22 Integrated Voltage Measurement... 20:08:31 Voltage Offset Correction: v_off_ini = 453.644 uV, v_off_fin = 461.467 uV 20:08:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.740 uVs 20:08:31 Integrated Voltage Measurement... 20:08:40 Voltage Offset Correction: v_off_ini = 450.083 uV, v_off_fin = 440.776 uV 20:08:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.478 uVs 20:08:40 Integrated Voltage Measurement... 20:08:49 Voltage Offset Correction: v_off_ini = 460.199 uV, v_off_fin = 460.402 uV 20:08:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.063 uVs 20:08:51 I2X Average and RMS of Measurements VT = -140.552 +- 5.918 uVs I2X = 12.931 +- 0.545 uTm^2 20:08:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:08:59 Integrated Voltage Measurement... 20:09:08 Voltage Offset Correction: v_off_ini = 447.897 uV, v_off_fin = 455.834 uV 20:09:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.891 uVs 20:09:08 Integrated Voltage Measurement... 20:09:17 Voltage Offset Correction: v_off_ini = 454.893 uV, v_off_fin = 461.226 uV 20:09:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.624 uVs 20:09:17 Integrated Voltage Measurement... 20:09:26 Voltage Offset Correction: v_off_ini = 447.592 uV, v_off_fin = 454.456 uV 20:09:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.928 uVs 20:09:26 Integrated Voltage Measurement... 20:09:35 Voltage Offset Correction: v_off_ini = 463.790 uV, v_off_fin = 463.920 uV 20:09:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.635 uVs 20:09:35 Integrated Voltage Measurement... 20:09:44 Voltage Offset Correction: v_off_ini = 454.084 uV, v_off_fin = 465.394 uV 20:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.785 uVs 20:09:44 Integrated Voltage Measurement... 20:09:53 Voltage Offset Correction: v_off_ini = 458.508 uV, v_off_fin = 468.017 uV 20:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.208 uVs 20:09:56 I2Y Average and RMS of Measurements VT = -215.845 +- 2.139 uVs I2Y = -19.858 +- 0.197 uTm^2 20:10:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:10:05 Integrated Voltage Measurement... 20:10:13 Voltage Offset Correction: v_off_ini = 487.312 uV, v_off_fin = 466.084 uV 20:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.343 uVs 20:10:14 Integrated Voltage Measurement... 20:10:22 Voltage Offset Correction: v_off_ini = 467.808 uV, v_off_fin = 481.519 uV 20:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.711 uVs 20:10:23 Integrated Voltage Measurement... 20:10:31 Voltage Offset Correction: v_off_ini = 481.884 uV, v_off_fin = 480.502 uV 20:10:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.494 uVs 20:10:32 Integrated Voltage Measurement... 20:10:41 Voltage Offset Correction: v_off_ini = 480.876 uV, v_off_fin = 475.565 uV 20:10:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.737 uVs 20:10:41 Integrated Voltage Measurement... 20:10:50 Voltage Offset Correction: v_off_ini = 468.318 uV, v_off_fin = 462.749 uV 20:10:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.299 uVs 20:10:50 Integrated Voltage Measurement... 20:10:59 Voltage Offset Correction: v_off_ini = 477.721 uV, v_off_fin = 479.746 uV 20:10:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.101 uVs 20:11:03 I1X Average and RMS of Measurements VT = -144.281 +- 3.880 uVs I1X = 28.856 +- 0.776 uTm 20:11:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:11:10 Integrated Voltage Measurement... 20:11:18 Voltage Offset Correction: v_off_ini = 466.980 uV, v_off_fin = 470.787 uV 20:11:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.629 uVs 20:11:18 Integrated Voltage Measurement... 20:11:27 Voltage Offset Correction: v_off_ini = 479.962 uV, v_off_fin = 468.997 uV 20:11:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.638 uVs 20:11:27 Integrated Voltage Measurement... 20:11:36 Voltage Offset Correction: v_off_ini = 471.310 uV, v_off_fin = 462.880 uV 20:11:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.122 uVs 20:11:36 Integrated Voltage Measurement... 20:11:45 Voltage Offset Correction: v_off_ini = 466.521 uV, v_off_fin = 483.997 uV 20:11:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.823 uVs 20:11:45 Integrated Voltage Measurement... 20:11:54 Voltage Offset Correction: v_off_ini = 474.090 uV, v_off_fin = 458.026 uV 20:11:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.245 uVs 20:11:54 Integrated Voltage Measurement... 20:12:03 Voltage Offset Correction: v_off_ini = 461.914 uV, v_off_fin = 473.805 uV 20:12:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.674 uVs 20:12:08 I1Y Average and RMS of Measurements VT = -229.022 +- 3.601 uVs I1Y = -45.804 +- 0.720 uTm 20:12:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:12:15 Integrated Voltage Measurement... 20:12:24 Voltage Offset Correction: v_off_ini = 473.369 uV, v_off_fin = 460.671 uV 20:12:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.828 uVs 20:12:24 Integrated Voltage Measurement... 20:12:33 Voltage Offset Correction: v_off_ini = 466.302 uV, v_off_fin = 461.503 uV 20:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.191 uVs 20:12:33 Integrated Voltage Measurement... 20:12:42 Voltage Offset Correction: v_off_ini = 467.029 uV, v_off_fin = 462.011 uV 20:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.059 uVs 20:12:42 Integrated Voltage Measurement... 20:12:51 Voltage Offset Correction: v_off_ini = 463.957 uV, v_off_fin = 470.204 uV 20:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.275 uVs 20:12:51 Integrated Voltage Measurement... 20:13:00 Voltage Offset Correction: v_off_ini = 459.783 uV, v_off_fin = 448.181 uV 20:13:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.906 uVs 20:13:00 Integrated Voltage Measurement... 20:13:09 Voltage Offset Correction: v_off_ini = 450.651 uV, v_off_fin = 461.893 uV 20:13:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.971 uVs 20:13:12 I2X Average and RMS of Measurements VT = -157.705 +- 7.542 uVs I2X = 14.509 +- 0.694 uTm^2 20:13:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:13:19 Integrated Voltage Measurement... 20:13:28 Voltage Offset Correction: v_off_ini = 455.606 uV, v_off_fin = 448.385 uV 20:13:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.164 uVs 20:13:28 Integrated Voltage Measurement... 20:13:37 Voltage Offset Correction: v_off_ini = 452.920 uV, v_off_fin = 447.031 uV 20:13:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.446 uVs 20:13:38 Integrated Voltage Measurement... 20:13:46 Voltage Offset Correction: v_off_ini = 453.141 uV, v_off_fin = 447.436 uV 20:13:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.215 uVs 20:13:47 Integrated Voltage Measurement... 20:13:56 Voltage Offset Correction: v_off_ini = 443.908 uV, v_off_fin = 448.050 uV 20:13:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.614 uVs 20:13:56 Integrated Voltage Measurement... 20:14:05 Voltage Offset Correction: v_off_ini = 449.682 uV, v_off_fin = 448.157 uV 20:14:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.456 uVs 20:14:05 Integrated Voltage Measurement... 20:14:14 Voltage Offset Correction: v_off_ini = 440.050 uV, v_off_fin = 448.790 uV 20:14:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.215 uVs 20:14:16 I2Y Average and RMS of Measurements VT = -230.185 +- 6.529 uVs I2Y = -21.177 +- 0.601 uTm^2 20:14:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:14:25 Integrated Voltage Measurement... 20:14:34 Voltage Offset Correction: v_off_ini = 441.664 uV, v_off_fin = 438.705 uV 20:14:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.893 uVs 20:14:34 Integrated Voltage Measurement... 20:14:43 Voltage Offset Correction: v_off_ini = 437.509 uV, v_off_fin = 441.368 uV 20:14:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.685 uVs 20:14:43 Integrated Voltage Measurement... 20:14:52 Voltage Offset Correction: v_off_ini = 442.382 uV, v_off_fin = 439.178 uV 20:14:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.227 uVs 20:14:52 Integrated Voltage Measurement... 20:15:01 Voltage Offset Correction: v_off_ini = 437.510 uV, v_off_fin = 435.968 uV 20:15:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.833 uVs 20:15:01 Integrated Voltage Measurement... 20:15:10 Voltage Offset Correction: v_off_ini = 420.788 uV, v_off_fin = 413.690 uV 20:15:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.890 uVs 20:15:10 Integrated Voltage Measurement... 20:15:19 Voltage Offset Correction: v_off_ini = 427.215 uV, v_off_fin = 427.281 uV 20:15:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.245 uVs 20:15:23 I1X Average and RMS of Measurements VT = -140.629 +- 9.909 uVs I1X = 28.126 +- 1.982 uTm 20:15:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:15:30 Integrated Voltage Measurement... 20:15:39 Voltage Offset Correction: v_off_ini = 428.452 uV, v_off_fin = 419.981 uV 20:15:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.470 uVs 20:15:39 Integrated Voltage Measurement... 20:15:48 Voltage Offset Correction: v_off_ini = 425.701 uV, v_off_fin = 435.598 uV 20:15:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.636 uVs 20:15:48 Integrated Voltage Measurement... 20:15:57 Voltage Offset Correction: v_off_ini = 429.424 uV, v_off_fin = 414.160 uV 20:15:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.662 uVs 20:15:57 Integrated Voltage Measurement... 20:16:06 Voltage Offset Correction: v_off_ini = 422.598 uV, v_off_fin = 433.606 uV 20:16:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.536 uVs 20:16:06 Integrated Voltage Measurement... 20:16:15 Voltage Offset Correction: v_off_ini = 432.411 uV, v_off_fin = 423.434 uV 20:16:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.826 uVs 20:16:15 Integrated Voltage Measurement... 20:16:24 Voltage Offset Correction: v_off_ini = 427.422 uV, v_off_fin = 435.340 uV 20:16:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.263 uVs 20:16:28 I1Y Average and RMS of Measurements VT = -227.566 +- 5.383 uVs I1Y = -45.513 +- 1.077 uTm 20:16:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:16:36 Integrated Voltage Measurement... 20:16:45 Voltage Offset Correction: v_off_ini = 434.896 uV, v_off_fin = 436.555 uV 20:16:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.906 uVs 20:16:45 Integrated Voltage Measurement... 20:16:54 Voltage Offset Correction: v_off_ini = 437.562 uV, v_off_fin = 445.012 uV 20:16:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.713 uVs 20:16:54 Integrated Voltage Measurement... 20:17:03 Voltage Offset Correction: v_off_ini = 443.037 uV, v_off_fin = 438.501 uV 20:17:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.128 uVs 20:17:03 Integrated Voltage Measurement... 20:17:12 Voltage Offset Correction: v_off_ini = 446.556 uV, v_off_fin = 439.856 uV 20:17:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.162 uVs 20:17:12 Integrated Voltage Measurement... 20:17:21 Voltage Offset Correction: v_off_ini = 440.621 uV, v_off_fin = 424.285 uV 20:17:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.165 uVs 20:17:21 Integrated Voltage Measurement... 20:17:30 Voltage Offset Correction: v_off_ini = 436.018 uV, v_off_fin = 433.612 uV 20:17:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.930 uVs 20:17:32 I2X Average and RMS of Measurements VT = -149.167 +- 1.884 uVs I2X = 13.723 +- 0.173 uTm^2 20:17:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:17:40 Integrated Voltage Measurement... 20:17:49 Voltage Offset Correction: v_off_ini = 430.826 uV, v_off_fin = 424.265 uV 20:17:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.137 uVs 20:17:49 Integrated Voltage Measurement... 20:17:58 Voltage Offset Correction: v_off_ini = 412.769 uV, v_off_fin = 420.184 uV 20:17:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.644 uVs 20:17:58 Integrated Voltage Measurement... 20:18:07 Voltage Offset Correction: v_off_ini = 428.632 uV, v_off_fin = 430.729 uV 20:18:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.826 uVs 20:18:07 Integrated Voltage Measurement... 20:18:16 Voltage Offset Correction: v_off_ini = 430.874 uV, v_off_fin = 445.072 uV 20:18:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 226.486 uVs 20:18:16 Integrated Voltage Measurement... 20:18:25 Voltage Offset Correction: v_off_ini = 438.664 uV, v_off_fin = 437.453 uV 20:18:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.336 uVs 20:18:25 Integrated Voltage Measurement... 20:18:34 Voltage Offset Correction: v_off_ini = 437.427 uV, v_off_fin = 429.031 uV 20:18:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.409 uVs 20:18:36 I2Y Average and RMS of Measurements VT = -223.973 +- 1.350 uVs I2Y = -20.606 +- 0.124 uTm^2 20:18:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:18:45 Integrated Voltage Measurement... 20:18:54 Voltage Offset Correction: v_off_ini = 441.952 uV, v_off_fin = 438.381 uV 20:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -138.483 uVs 20:18:54 Integrated Voltage Measurement... 20:19:03 Voltage Offset Correction: v_off_ini = 443.859 uV, v_off_fin = 439.226 uV 20:19:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.223 uVs 20:19:03 Integrated Voltage Measurement... 20:19:12 Voltage Offset Correction: v_off_ini = 449.152 uV, v_off_fin = 438.532 uV 20:19:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.810 uVs 20:19:12 Integrated Voltage Measurement... 20:19:21 Voltage Offset Correction: v_off_ini = 429.946 uV, v_off_fin = 449.235 uV 20:19:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 154.476 uVs 20:19:21 Integrated Voltage Measurement... 20:19:30 Voltage Offset Correction: v_off_ini = 444.000 uV, v_off_fin = 436.051 uV 20:19:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -138.026 uVs 20:19:30 Integrated Voltage Measurement... 20:19:39 Voltage Offset Correction: v_off_ini = 454.213 uV, v_off_fin = 443.458 uV 20:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.076 uVs 20:19:43 I1X Average and RMS of Measurements VT = -144.849 +- 4.860 uVs I1X = 28.972 +- 0.973 uTm 20:19:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:19:50 Integrated Voltage Measurement... 20:19:59 Voltage Offset Correction: v_off_ini = 456.679 uV, v_off_fin = 446.919 uV 20:19:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.133 uVs 20:19:59 Integrated Voltage Measurement... 20:20:08 Voltage Offset Correction: v_off_ini = 439.887 uV, v_off_fin = 457.698 uV 20:20:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.682 uVs 20:20:08 Integrated Voltage Measurement... 20:20:17 Voltage Offset Correction: v_off_ini = 455.445 uV, v_off_fin = 448.343 uV 20:20:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.627 uVs 20:20:17 Integrated Voltage Measurement... 20:20:26 Voltage Offset Correction: v_off_ini = 458.746 uV, v_off_fin = 466.806 uV 20:20:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.374 uVs 20:20:26 Integrated Voltage Measurement... 20:20:35 Voltage Offset Correction: v_off_ini = 454.561 uV, v_off_fin = 451.157 uV 20:20:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.153 uVs 20:20:35 Integrated Voltage Measurement... 20:20:44 Voltage Offset Correction: v_off_ini = 457.456 uV, v_off_fin = 470.257 uV 20:20:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.955 uVs 20:20:48 I1Y Average and RMS of Measurements VT = -232.987 +- 3.517 uVs I1Y = -46.597 +- 0.703 uTm 20:20:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:20:56 Integrated Voltage Measurement... 20:21:05 Voltage Offset Correction: v_off_ini = 449.447 uV, v_off_fin = 449.098 uV 20:21:05 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -143.532 uVs 20:21:05 Integrated Voltage Measurement... 20:21:14 Voltage Offset Correction: v_off_ini = 460.698 uV, v_off_fin = 472.073 uV 20:21:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.383 uVs 20:21:14 Integrated Voltage Measurement... 20:21:23 Voltage Offset Correction: v_off_ini = 470.277 uV, v_off_fin = 456.209 uV 20:21:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.918 uVs 20:21:23 Integrated Voltage Measurement... 20:21:32 Voltage Offset Correction: v_off_ini = 466.462 uV, v_off_fin = 462.075 uV 20:21:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.554 uVs 20:21:32 Integrated Voltage Measurement... 20:21:41 Voltage Offset Correction: v_off_ini = 463.628 uV, v_off_fin = 465.918 uV 20:21:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.814 uVs 20:21:41 Integrated Voltage Measurement... 20:21:50 Voltage Offset Correction: v_off_ini = 463.389 uV, v_off_fin = 463.186 uV 20:21:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.317 uVs 20:21:53 I2X Average and RMS of Measurements VT = -146.586 +- 3.430 uVs I2X = 13.486 +- 0.316 uTm^2 20:21:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:22:00 Integrated Voltage Measurement... 20:22:09 Voltage Offset Correction: v_off_ini = 462.352 uV, v_off_fin = 470.936 uV 20:22:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.192 uVs 20:22:09 Integrated Voltage Measurement... 20:22:18 Voltage Offset Correction: v_off_ini = 471.291 uV, v_off_fin = 467.816 uV 20:22:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.991 uVs 20:22:19 Integrated Voltage Measurement... 20:22:27 Voltage Offset Correction: v_off_ini = 466.747 uV, v_off_fin = 466.571 uV 20:22:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -228.501 uVs 20:22:28 Integrated Voltage Measurement... 20:22:37 Voltage Offset Correction: v_off_ini = 462.178 uV, v_off_fin = 464.339 uV 20:22:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.318 uVs 20:22:37 Integrated Voltage Measurement... 20:22:46 Voltage Offset Correction: v_off_ini = 463.889 uV, v_off_fin = 463.239 uV 20:22:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.456 uVs 20:22:46 Integrated Voltage Measurement... 20:22:55 Voltage Offset Correction: v_off_ini = 460.100 uV, v_off_fin = 465.072 uV 20:22:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.257 uVs 20:22:57 I2Y Average and RMS of Measurements VT = -232.619 +- 2.524 uVs I2Y = -21.401 +- 0.232 uTm^2 20:23:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:23:09 Integrated Voltage Measurement... 20:23:18 Voltage Offset Correction: v_off_ini = 471.052 uV, v_off_fin = 473.274 uV 20:23:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.796 uVs 20:23:18 Integrated Voltage Measurement... 20:23:27 Voltage Offset Correction: v_off_ini = 476.625 uV, v_off_fin = 467.331 uV 20:23:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.325 uVs 20:23:27 Integrated Voltage Measurement... 20:23:36 Voltage Offset Correction: v_off_ini = 472.896 uV, v_off_fin = 472.740 uV 20:23:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.718 uVs 20:23:36 Integrated Voltage Measurement... 20:23:45 Voltage Offset Correction: v_off_ini = 472.649 uV, v_off_fin = 472.189 uV 20:23:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.035 uVs 20:23:45 Integrated Voltage Measurement... 20:23:54 Voltage Offset Correction: v_off_ini = 473.164 uV, v_off_fin = 471.712 uV 20:23:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.638 uVs 20:23:54 Integrated Voltage Measurement... 20:24:03 Voltage Offset Correction: v_off_ini = 472.109 uV, v_off_fin = 472.591 uV 20:24:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.482 uVs 20:24:07 I1X Average and RMS of Measurements VT = -137.666 +- 5.390 uVs I1X = 27.534 +- 1.079 uTm 20:24:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:24:14 Integrated Voltage Measurement... 20:24:23 Voltage Offset Correction: v_off_ini = 469.669 uV, v_off_fin = 458.603 uV 20:24:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.106 uVs 20:24:23 Integrated Voltage Measurement... 20:24:32 Voltage Offset Correction: v_off_ini = 476.822 uV, v_off_fin = 477.825 uV 20:24:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.191 uVs 20:24:32 Integrated Voltage Measurement... 20:24:41 Voltage Offset Correction: v_off_ini = 474.541 uV, v_off_fin = 465.840 uV 20:24:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.379 uVs 20:24:41 Integrated Voltage Measurement... 20:24:50 Voltage Offset Correction: v_off_ini = 475.958 uV, v_off_fin = 469.147 uV 20:24:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.290 uVs 20:24:50 Integrated Voltage Measurement... 20:24:59 Voltage Offset Correction: v_off_ini = 460.092 uV, v_off_fin = 444.651 uV 20:24:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.993 uVs 20:24:59 Integrated Voltage Measurement... 20:25:08 Voltage Offset Correction: v_off_ini = 450.717 uV, v_off_fin = 471.405 uV 20:25:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.669 uVs 20:25:12 I1Y Average and RMS of Measurements VT = -223.271 +- 4.723 uVs I1Y = -44.654 +- 0.945 uTm 20:25:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:25:17 Integrated Voltage Measurement... 20:25:26 Voltage Offset Correction: v_off_ini = 448.076 uV, v_off_fin = 466.183 uV 20:25:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.367 uVs 20:25:26 Integrated Voltage Measurement... 20:25:35 Voltage Offset Correction: v_off_ini = 470.281 uV, v_off_fin = 473.405 uV 20:25:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.700 uVs 20:25:35 Integrated Voltage Measurement... 20:25:44 Voltage Offset Correction: v_off_ini = 480.471 uV, v_off_fin = 453.483 uV 20:25:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.187 uVs 20:25:45 Integrated Voltage Measurement... 20:25:53 Voltage Offset Correction: v_off_ini = 454.703 uV, v_off_fin = 460.638 uV 20:25:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.220 uVs 20:25:54 Integrated Voltage Measurement... 20:26:03 Voltage Offset Correction: v_off_ini = 454.057 uV, v_off_fin = 450.861 uV 20:26:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.775 uVs 20:26:03 Integrated Voltage Measurement... 20:26:12 Voltage Offset Correction: v_off_ini = 450.002 uV, v_off_fin = 462.624 uV 20:26:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.212 uVs 20:26:14 I2X Average and RMS of Measurements VT = -143.744 +- 8.933 uVs I2X = 13.225 +- 0.822 uTm^2 20:26:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:26:19 Integrated Voltage Measurement... 20:26:28 Voltage Offset Correction: v_off_ini = 445.830 uV, v_off_fin = 446.431 uV 20:26:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.122 uVs 20:26:28 Integrated Voltage Measurement... 20:26:37 Voltage Offset Correction: v_off_ini = 451.090 uV, v_off_fin = 461.437 uV 20:26:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.215 uVs 20:26:37 Integrated Voltage Measurement... 20:26:46 Voltage Offset Correction: v_off_ini = 465.005 uV, v_off_fin = 457.356 uV 20:26:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.496 uVs 20:26:46 Integrated Voltage Measurement... 20:26:55 Voltage Offset Correction: v_off_ini = 449.172 uV, v_off_fin = 461.514 uV 20:26:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.523 uVs 20:26:55 Integrated Voltage Measurement... 20:27:04 Voltage Offset Correction: v_off_ini = 450.324 uV, v_off_fin = 454.605 uV 20:27:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.117 uVs 20:27:04 Integrated Voltage Measurement... 20:27:13 Voltage Offset Correction: v_off_ini = 459.820 uV, v_off_fin = 459.329 uV 20:27:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.624 uVs 20:27:16 I2Y Average and RMS of Measurements VT = -223.683 +- 8.048 uVs I2Y = -20.579 +- 0.740 uTm^2 20:27:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:27:24 Integrated Voltage Measurement... 20:27:33 Voltage Offset Correction: v_off_ini = 466.761 uV, v_off_fin = 460.578 uV 20:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.755 uVs 20:27:33 Integrated Voltage Measurement... 20:27:42 Voltage Offset Correction: v_off_ini = 460.211 uV, v_off_fin = 466.693 uV 20:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.773 uVs 20:27:42 Integrated Voltage Measurement... 20:27:51 Voltage Offset Correction: v_off_ini = 470.223 uV, v_off_fin = 458.791 uV 20:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.326 uVs 20:27:51 Integrated Voltage Measurement... 20:28:00 Voltage Offset Correction: v_off_ini = 471.879 uV, v_off_fin = 464.232 uV 20:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.582 uVs 20:28:00 Integrated Voltage Measurement... 20:28:09 Voltage Offset Correction: v_off_ini = 477.649 uV, v_off_fin = 482.167 uV 20:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.672 uVs 20:28:09 Integrated Voltage Measurement... 20:28:18 Voltage Offset Correction: v_off_ini = 469.041 uV, v_off_fin = 473.389 uV 20:28:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.813 uVs 20:28:22 I1X Average and RMS of Measurements VT = -136.487 +- 1.438 uVs I1X = 27.298 +- 0.288 uTm 20:28:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:28:29 Integrated Voltage Measurement... 20:28:38 Voltage Offset Correction: v_off_ini = 462.209 uV, v_off_fin = 446.202 uV 20:28:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.543 uVs 20:28:38 Integrated Voltage Measurement... 20:28:47 Voltage Offset Correction: v_off_ini = 463.547 uV, v_off_fin = 480.273 uV 20:28:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.732 uVs 20:28:47 Integrated Voltage Measurement... 20:28:56 Voltage Offset Correction: v_off_ini = 455.607 uV, v_off_fin = 459.466 uV 20:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.654 uVs 20:28:56 Integrated Voltage Measurement... 20:29:05 Voltage Offset Correction: v_off_ini = 465.269 uV, v_off_fin = 473.298 uV 20:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.765 uVs 20:29:05 Integrated Voltage Measurement... 20:29:14 Voltage Offset Correction: v_off_ini = 457.266 uV, v_off_fin = 461.339 uV 20:29:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.328 uVs 20:29:14 Integrated Voltage Measurement... 20:29:23 Voltage Offset Correction: v_off_ini = 459.448 uV, v_off_fin = 473.661 uV 20:29:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.777 uVs 20:29:27 I1Y Average and RMS of Measurements VT = -232.300 +- 5.380 uVs I1Y = -46.460 +- 1.076 uTm 20:29:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:29:33 Integrated Voltage Measurement... 20:29:41 Voltage Offset Correction: v_off_ini = 450.482 uV, v_off_fin = 438.379 uV 20:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.297 uVs 20:29:42 Integrated Voltage Measurement... 20:29:51 Voltage Offset Correction: v_off_ini = 452.108 uV, v_off_fin = 460.302 uV 20:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.854 uVs 20:29:51 Integrated Voltage Measurement... 20:30:00 Voltage Offset Correction: v_off_ini = 465.915 uV, v_off_fin = 444.375 uV 20:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.001 uVs 20:30:00 Integrated Voltage Measurement... 20:30:09 Voltage Offset Correction: v_off_ini = 455.024 uV, v_off_fin = 464.921 uV 20:30:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.555 uVs 20:30:09 Integrated Voltage Measurement... 20:30:18 Voltage Offset Correction: v_off_ini = 450.494 uV, v_off_fin = 452.072 uV 20:30:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.624 uVs 20:30:18 Integrated Voltage Measurement... 20:30:27 Voltage Offset Correction: v_off_ini = 458.543 uV, v_off_fin = 447.875 uV 20:30:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 167.393 uVs 20:30:29 I2X Average and RMS of Measurements VT = -143.621 +- 12.420 uVs I2X = 13.213 +- 1.143 uTm^2 20:30:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:30:34 Integrated Voltage Measurement... 20:30:43 Voltage Offset Correction: v_off_ini = 429.031 uV, v_off_fin = 447.648 uV 20:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.105 uVs 20:30:43 Integrated Voltage Measurement... 20:30:52 Voltage Offset Correction: v_off_ini = 447.552 uV, v_off_fin = 450.963 uV 20:30:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.977 uVs 20:30:52 Integrated Voltage Measurement... 20:31:01 Voltage Offset Correction: v_off_ini = 447.561 uV, v_off_fin = 451.384 uV 20:31:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.397 uVs 20:31:01 Integrated Voltage Measurement... 20:31:10 Voltage Offset Correction: v_off_ini = 456.922 uV, v_off_fin = 446.763 uV 20:31:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.710 uVs 20:31:10 Integrated Voltage Measurement... 20:31:19 Voltage Offset Correction: v_off_ini = 428.852 uV, v_off_fin = 445.043 uV 20:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.763 uVs 20:31:19 Integrated Voltage Measurement... 20:31:28 Voltage Offset Correction: v_off_ini = 448.731 uV, v_off_fin = 445.688 uV 20:31:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.657 uVs 20:31:31 I2Y Average and RMS of Measurements VT = -225.435 +- 4.994 uVs I2Y = -20.740 +- 0.459 uTm^2 20:31:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:31:39 Integrated Voltage Measurement... 20:31:48 Voltage Offset Correction: v_off_ini = 438.747 uV, v_off_fin = 444.159 uV 20:31:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -138.938 uVs 20:31:48 Integrated Voltage Measurement... 20:31:57 Voltage Offset Correction: v_off_ini = 449.330 uV, v_off_fin = 441.210 uV 20:31:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.332 uVs 20:31:57 Integrated Voltage Measurement... 20:32:06 Voltage Offset Correction: v_off_ini = 444.735 uV, v_off_fin = 443.872 uV 20:32:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.972 uVs 20:32:06 Integrated Voltage Measurement... 20:32:15 Voltage Offset Correction: v_off_ini = 431.955 uV, v_off_fin = 453.181 uV 20:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.784 uVs 20:32:15 Integrated Voltage Measurement... 20:32:24 Voltage Offset Correction: v_off_ini = 436.339 uV, v_off_fin = 435.885 uV 20:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.178 uVs 20:32:24 Integrated Voltage Measurement... 20:32:33 Voltage Offset Correction: v_off_ini = 441.310 uV, v_off_fin = 438.255 uV 20:32:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.064 uVs 20:32:37 I1X Average and RMS of Measurements VT = -143.711 +- 3.379 uVs I1X = 28.743 +- 0.676 uTm 20:32:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:32:44 Integrated Voltage Measurement... 20:32:53 Voltage Offset Correction: v_off_ini = 435.795 uV, v_off_fin = 441.591 uV 20:32:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.217 uVs 20:32:53 Integrated Voltage Measurement... 20:33:02 Voltage Offset Correction: v_off_ini = 448.285 uV, v_off_fin = 459.751 uV 20:33:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.983 uVs 20:33:02 Integrated Voltage Measurement... 20:33:11 Voltage Offset Correction: v_off_ini = 445.444 uV, v_off_fin = 440.798 uV 20:33:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.893 uVs 20:33:11 Integrated Voltage Measurement... 20:33:20 Voltage Offset Correction: v_off_ini = 449.497 uV, v_off_fin = 452.052 uV 20:33:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.231 uVs 20:33:20 Integrated Voltage Measurement... 20:33:29 Voltage Offset Correction: v_off_ini = 458.859 uV, v_off_fin = 426.176 uV 20:33:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.735 uVs 20:33:29 Integrated Voltage Measurement... 20:33:38 Voltage Offset Correction: v_off_ini = 446.442 uV, v_off_fin = 451.510 uV 20:33:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.425 uVs 20:33:42 I1Y Average and RMS of Measurements VT = -231.247 +- 3.690 uVs I1Y = -46.249 +- 0.738 uTm 20:33:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:33:48 Integrated Voltage Measurement... 20:33:57 Voltage Offset Correction: v_off_ini = 437.956 uV, v_off_fin = 444.263 uV 20:33:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.636 uVs 20:33:57 Integrated Voltage Measurement... 20:34:06 Voltage Offset Correction: v_off_ini = 450.686 uV, v_off_fin = 456.796 uV 20:34:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.421 uVs 20:34:06 Integrated Voltage Measurement... 20:34:15 Voltage Offset Correction: v_off_ini = 448.389 uV, v_off_fin = 446.010 uV 20:34:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.352 uVs 20:34:15 Integrated Voltage Measurement... 20:34:24 Voltage Offset Correction: v_off_ini = 455.063 uV, v_off_fin = 457.788 uV 20:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.217 uVs 20:34:24 Integrated Voltage Measurement... 20:34:33 Voltage Offset Correction: v_off_ini = 439.603 uV, v_off_fin = 439.388 uV 20:34:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.746 uVs 20:34:33 Integrated Voltage Measurement... 20:34:42 Voltage Offset Correction: v_off_ini = 460.957 uV, v_off_fin = 468.048 uV 20:34:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.334 uVs 20:34:44 I2X Average and RMS of Measurements VT = -141.951 +- 9.901 uVs I2X = 13.059 +- 0.911 uTm^2 20:34:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:34:49 Integrated Voltage Measurement... 20:34:58 Voltage Offset Correction: v_off_ini = 448.685 uV, v_off_fin = 458.228 uV 20:34:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -219.336 uVs 20:34:58 Integrated Voltage Measurement... 20:35:07 Voltage Offset Correction: v_off_ini = 454.502 uV, v_off_fin = 452.423 uV 20:35:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 231.040 uVs 20:35:07 Integrated Voltage Measurement... 20:35:16 Voltage Offset Correction: v_off_ini = 458.493 uV, v_off_fin = 459.218 uV 20:35:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.220 uVs 20:35:16 Integrated Voltage Measurement... 20:35:25 Voltage Offset Correction: v_off_ini = 457.625 uV, v_off_fin = 449.123 uV 20:35:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.630 uVs 20:35:25 Integrated Voltage Measurement... 20:35:34 Voltage Offset Correction: v_off_ini = 457.812 uV, v_off_fin = 465.226 uV 20:35:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.302 uVs 20:35:34 Integrated Voltage Measurement... 20:35:43 Voltage Offset Correction: v_off_ini = 458.487 uV, v_off_fin = 466.650 uV 20:35:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 219.069 uVs 20:35:46 I2Y Average and RMS of Measurements VT = -225.100 +- 2.752 uVs I2Y = -20.709 +- 0.253 uTm^2 20:35:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:35:54 Integrated Voltage Measurement... 20:36:03 Voltage Offset Correction: v_off_ini = 461.547 uV, v_off_fin = 466.374 uV 20:36:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.587 uVs 20:36:03 Integrated Voltage Measurement... 20:36:12 Voltage Offset Correction: v_off_ini = 458.964 uV, v_off_fin = 464.358 uV 20:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.662 uVs 20:36:12 Integrated Voltage Measurement... 20:36:21 Voltage Offset Correction: v_off_ini = 455.661 uV, v_off_fin = 459.507 uV 20:36:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.769 uVs 20:36:21 Integrated Voltage Measurement... 20:36:30 Voltage Offset Correction: v_off_ini = 467.735 uV, v_off_fin = 457.888 uV 20:36:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.034 uVs 20:36:30 Integrated Voltage Measurement... 20:36:39 Voltage Offset Correction: v_off_ini = 459.736 uV, v_off_fin = 457.835 uV 20:36:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.269 uVs 20:36:39 Integrated Voltage Measurement... 20:36:48 Voltage Offset Correction: v_off_ini = 457.920 uV, v_off_fin = 462.421 uV 20:36:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.120 uVs 20:36:52 I1X Average and RMS of Measurements VT = -147.407 +- 2.212 uVs I1X = 29.482 +- 0.442 uTm 20:36:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:36:59 Integrated Voltage Measurement... 20:37:08 Voltage Offset Correction: v_off_ini = 465.118 uV, v_off_fin = 449.760 uV 20:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.349 uVs 20:37:08 Integrated Voltage Measurement... 20:37:17 Voltage Offset Correction: v_off_ini = 453.638 uV, v_off_fin = 475.315 uV 20:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.587 uVs 20:37:17 Integrated Voltage Measurement... 20:37:26 Voltage Offset Correction: v_off_ini = 459.956 uV, v_off_fin = 465.427 uV 20:37:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.395 uVs 20:37:26 Integrated Voltage Measurement... 20:37:35 Voltage Offset Correction: v_off_ini = 464.721 uV, v_off_fin = 483.795 uV 20:37:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.210 uVs 20:37:35 Integrated Voltage Measurement... 20:37:44 Voltage Offset Correction: v_off_ini = 459.886 uV, v_off_fin = 453.780 uV 20:37:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.862 uVs 20:37:44 Integrated Voltage Measurement... 20:37:53 Voltage Offset Correction: v_off_ini = 462.966 uV, v_off_fin = 472.181 uV 20:37:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.724 uVs 20:37:57 I1Y Average and RMS of Measurements VT = -229.521 +- 2.728 uVs I1Y = -45.903 +- 0.543 uTm 20:38:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:38:03 Integrated Voltage Measurement... 20:38:12 Voltage Offset Correction: v_off_ini = 444.583 uV, v_off_fin = 446.297 uV 20:38:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.791 uVs 20:38:12 Integrated Voltage Measurement... 20:38:21 Voltage Offset Correction: v_off_ini = 447.757 uV, v_off_fin = 455.959 uV 20:38:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.913 uVs 20:38:21 Integrated Voltage Measurement... 20:38:30 Voltage Offset Correction: v_off_ini = 459.918 uV, v_off_fin = 454.314 uV 20:38:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.586 uVs 20:38:30 Integrated Voltage Measurement... 20:38:39 Voltage Offset Correction: v_off_ini = 461.939 uV, v_off_fin = 465.846 uV 20:38:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.023 uVs 20:38:39 Integrated Voltage Measurement... 20:38:48 Voltage Offset Correction: v_off_ini = 459.539 uV, v_off_fin = 462.744 uV 20:38:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.630 uVs 20:38:48 Integrated Voltage Measurement... 20:38:57 Voltage Offset Correction: v_off_ini = 462.058 uV, v_off_fin = 461.396 uV 20:38:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.476 uVs 20:38:59 I2X Average and RMS of Measurements VT = -145.070 +- 4.296 uVs I2X = 13.346 +- 0.395 uTm^2 20:39:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:39:04 Integrated Voltage Measurement... 20:39:13 Voltage Offset Correction: v_off_ini = 461.036 uV, v_off_fin = 463.703 uV 20:39:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.462 uVs 20:39:13 Integrated Voltage Measurement... 20:39:22 Voltage Offset Correction: v_off_ini = 470.304 uV, v_off_fin = 464.321 uV 20:39:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.915 uVs 20:39:22 Integrated Voltage Measurement... 20:39:31 Voltage Offset Correction: v_off_ini = 460.006 uV, v_off_fin = 456.561 uV 20:39:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.153 uVs 20:39:31 Integrated Voltage Measurement... 20:39:40 Voltage Offset Correction: v_off_ini = 448.840 uV, v_off_fin = 461.682 uV 20:39:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.074 uVs 20:39:40 Integrated Voltage Measurement... 20:39:49 Voltage Offset Correction: v_off_ini = 458.103 uV, v_off_fin = 456.264 uV 20:39:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.409 uVs 20:39:50 Integrated Voltage Measurement... 20:39:58 Voltage Offset Correction: v_off_ini = 467.420 uV, v_off_fin = 449.582 uV 20:39:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.732 uVs 20:40:01 I2Y Average and RMS of Measurements VT = -228.791 +- 1.614 uVs I2Y = -21.049 +- 0.149 uTm^2 20:40:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:40:09 Integrated Voltage Measurement... 20:40:18 Voltage Offset Correction: v_off_ini = 462.506 uV, v_off_fin = 455.733 uV 20:40:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.730 uVs 20:40:18 Integrated Voltage Measurement... 20:40:27 Voltage Offset Correction: v_off_ini = 453.430 uV, v_off_fin = 451.771 uV 20:40:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.204 uVs 20:40:27 Integrated Voltage Measurement... 20:40:36 Voltage Offset Correction: v_off_ini = 459.795 uV, v_off_fin = 465.784 uV 20:40:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.346 uVs 20:40:36 Integrated Voltage Measurement... 20:40:45 Voltage Offset Correction: v_off_ini = 457.549 uV, v_off_fin = 452.033 uV 20:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.887 uVs 20:40:45 Integrated Voltage Measurement... 20:40:54 Voltage Offset Correction: v_off_ini = 440.809 uV, v_off_fin = 439.702 uV 20:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.014 uVs 20:40:54 Integrated Voltage Measurement... 20:41:03 Voltage Offset Correction: v_off_ini = 449.877 uV, v_off_fin = 450.035 uV 20:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.455 uVs 20:41:08 I1X Average and RMS of Measurements VT = -135.939 +- 2.695 uVs I1X = 27.188 +- 0.539 uTm 20:41:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:41:14 Integrated Voltage Measurement... 20:41:23 Voltage Offset Correction: v_off_ini = 448.168 uV, v_off_fin = 433.397 uV 20:41:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -231.426 uVs 20:41:23 Integrated Voltage Measurement... 20:41:32 Voltage Offset Correction: v_off_ini = 467.846 uV, v_off_fin = 475.786 uV 20:41:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.735 uVs 20:41:32 Integrated Voltage Measurement... 20:41:41 Voltage Offset Correction: v_off_ini = 465.473 uV, v_off_fin = 450.274 uV 20:41:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.123 uVs 20:41:41 Integrated Voltage Measurement... 20:41:50 Voltage Offset Correction: v_off_ini = 459.568 uV, v_off_fin = 473.945 uV 20:41:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.059 uVs 20:41:50 Integrated Voltage Measurement... 20:41:59 Voltage Offset Correction: v_off_ini = 461.340 uV, v_off_fin = 447.292 uV 20:41:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.024 uVs 20:41:59 Integrated Voltage Measurement... 20:42:08 Voltage Offset Correction: v_off_ini = 457.895 uV, v_off_fin = 471.019 uV 20:42:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.514 uVs 20:42:13 I1Y Average and RMS of Measurements VT = -226.147 +- 1.934 uVs I1Y = -45.227 +- 0.387 uTm 20:42:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:42:18 Integrated Voltage Measurement... 20:42:27 Voltage Offset Correction: v_off_ini = 458.480 uV, v_off_fin = 448.886 uV 20:42:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.664 uVs 20:42:27 Integrated Voltage Measurement... 20:42:36 Voltage Offset Correction: v_off_ini = 461.511 uV, v_off_fin = 455.858 uV 20:42:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.193 uVs 20:42:36 Integrated Voltage Measurement... 20:42:45 Voltage Offset Correction: v_off_ini = 452.711 uV, v_off_fin = 449.070 uV 20:42:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.313 uVs 20:42:45 Integrated Voltage Measurement... 20:42:54 Voltage Offset Correction: v_off_ini = 450.834 uV, v_off_fin = 459.109 uV 20:42:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.150 uVs 20:42:54 Integrated Voltage Measurement... 20:43:03 Voltage Offset Correction: v_off_ini = 443.296 uV, v_off_fin = 431.115 uV 20:43:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.482 uVs 20:43:03 Integrated Voltage Measurement... 20:43:12 Voltage Offset Correction: v_off_ini = 447.759 uV, v_off_fin = 446.779 uV 20:43:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.922 uVs 20:43:14 I2X Average and RMS of Measurements VT = -135.287 +- 1.962 uVs I2X = 12.446 +- 0.180 uTm^2 20:43:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:43:19 Integrated Voltage Measurement... 20:43:28 Voltage Offset Correction: v_off_ini = 429.361 uV, v_off_fin = 426.471 uV 20:43:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.094 uVs 20:43:28 Integrated Voltage Measurement... 20:43:37 Voltage Offset Correction: v_off_ini = 433.695 uV, v_off_fin = 434.105 uV 20:43:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.661 uVs 20:43:38 Integrated Voltage Measurement... 20:43:47 Voltage Offset Correction: v_off_ini = 431.060 uV, v_off_fin = 425.124 uV 20:43:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.493 uVs 20:43:47 Integrated Voltage Measurement... 20:43:56 Voltage Offset Correction: v_off_ini = 423.337 uV, v_off_fin = 418.089 uV 20:43:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.535 uVs 20:43:56 Integrated Voltage Measurement... 20:44:05 Voltage Offset Correction: v_off_ini = 405.060 uV, v_off_fin = 407.206 uV 20:44:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.043 uVs 20:44:05 Integrated Voltage Measurement... 20:44:14 Voltage Offset Correction: v_off_ini = 405.643 uV, v_off_fin = 419.009 uV 20:44:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.153 uVs 20:44:16 I2Y Average and RMS of Measurements VT = -228.830 +- 12.009 uVs I2Y = -21.052 +- 1.105 uTm^2 20:44:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm