SLAC Magnetic Measurements Date: 10-27-2025 Time: 16:18:59 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16350 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 16:19:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:09 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:19:10 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:19:12 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:19:13 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:19:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:35 Integrated Voltage Measurement... 16:19:44 Voltage Offset Correction: v_off_ini = -245.157 uV, v_off_fin = -252.124 uV 16:19:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.225 uVs 16:19:44 Integrated Voltage Measurement... 16:19:53 Voltage Offset Correction: v_off_ini = -246.222 uV, v_off_fin = -258.106 uV 16:19:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.992 uVs 16:19:53 Integrated Voltage Measurement... 16:20:02 Voltage Offset Correction: v_off_ini = -250.867 uV, v_off_fin = -247.754 uV 16:20:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.587 uVs 16:20:02 Integrated Voltage Measurement... 16:20:11 Voltage Offset Correction: v_off_ini = -244.348 uV, v_off_fin = -250.841 uV 16:20:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.916 uVs 16:20:11 Integrated Voltage Measurement... 16:20:20 Voltage Offset Correction: v_off_ini = -244.395 uV, v_off_fin = -242.169 uV 16:20:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.062 uVs 16:20:20 Integrated Voltage Measurement... 16:20:29 Voltage Offset Correction: v_off_ini = -245.486 uV, v_off_fin = -246.980 uV 16:20:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.477 uVs 16:20:33 I1X Average and RMS of Measurements VT = -159.710 +- 3.683 uVs I1X = 31.942 +- 0.737 uTm 16:20:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:40 Integrated Voltage Measurement... 16:20:48 Voltage Offset Correction: v_off_ini = -244.044 uV, v_off_fin = -260.188 uV 16:20:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.099 uVs 16:20:49 Integrated Voltage Measurement... 16:20:57 Voltage Offset Correction: v_off_ini = -248.497 uV, v_off_fin = -235.238 uV 16:20:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.204 uVs 16:20:58 Integrated Voltage Measurement... 16:21:06 Voltage Offset Correction: v_off_ini = -240.553 uV, v_off_fin = -243.391 uV 16:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.396 uVs 16:21:06 Integrated Voltage Measurement... 16:21:15 Voltage Offset Correction: v_off_ini = -241.805 uV, v_off_fin = -235.138 uV 16:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.909 uVs 16:21:15 Integrated Voltage Measurement... 16:21:24 Voltage Offset Correction: v_off_ini = -228.481 uV, v_off_fin = -235.328 uV 16:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.884 uVs 16:21:24 Integrated Voltage Measurement... 16:21:33 Voltage Offset Correction: v_off_ini = -232.324 uV, v_off_fin = -226.662 uV 16:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.793 uVs 16:21:38 I1Y Average and RMS of Measurements VT = -257.047 +- 1.493 uVs I1Y = -51.409 +- 0.299 uTm 16:21:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:45 Integrated Voltage Measurement... 16:21:54 Voltage Offset Correction: v_off_ini = -234.582 uV, v_off_fin = -246.171 uV 16:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.683 uVs 16:21:54 Integrated Voltage Measurement... 16:22:03 Voltage Offset Correction: v_off_ini = -237.420 uV, v_off_fin = -224.773 uV 16:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.975 uVs 16:22:03 Integrated Voltage Measurement... 16:22:12 Voltage Offset Correction: v_off_ini = -252.629 uV, v_off_fin = -254.016 uV 16:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.061 uVs 16:22:12 Integrated Voltage Measurement... 16:22:21 Voltage Offset Correction: v_off_ini = -235.208 uV, v_off_fin = -241.629 uV 16:22:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 159.542 uVs 16:22:21 Integrated Voltage Measurement... 16:22:30 Voltage Offset Correction: v_off_ini = -244.777 uV, v_off_fin = -245.893 uV 16:22:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.062 uVs 16:22:30 Integrated Voltage Measurement... 16:22:39 Voltage Offset Correction: v_off_ini = -242.155 uV, v_off_fin = -229.962 uV 16:22:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 189.790 uVs 16:22:42 I2X Average and RMS of Measurements VT = -164.519 +- 5.512 uVs I2X = 15.136 +- 0.507 uTm^2 16:22:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:49 Integrated Voltage Measurement... 16:22:58 Voltage Offset Correction: v_off_ini = -263.348 uV, v_off_fin = -259.141 uV 16:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -499.872 uVs 16:22:58 Integrated Voltage Measurement... 16:23:07 Voltage Offset Correction: v_off_ini = -260.145 uV, v_off_fin = -254.438 uV 16:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.329 uVs 16:23:07 Integrated Voltage Measurement... 16:23:16 Voltage Offset Correction: v_off_ini = -249.289 uV, v_off_fin = -250.970 uV 16:23:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.193 uVs 16:23:16 Integrated Voltage Measurement... 16:23:25 Voltage Offset Correction: v_off_ini = -254.193 uV, v_off_fin = -241.643 uV 16:23:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 511.419 uVs 16:23:26 Integrated Voltage Measurement... 16:23:34 Voltage Offset Correction: v_off_ini = -241.618 uV, v_off_fin = -251.847 uV 16:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.028 uVs 16:23:35 Integrated Voltage Measurement... 16:23:43 Voltage Offset Correction: v_off_ini = -253.840 uV, v_off_fin = -243.841 uV 16:23:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 515.832 uVs 16:23:46 I2Y Average and RMS of Measurements VT = -502.112 +- 3.993 uVs I2Y = -46.194 +- 0.367 uTm^2 16:23:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:01 Integrated Voltage Measurement... 16:24:10 Voltage Offset Correction: v_off_ini = -236.807 uV, v_off_fin = -238.923 uV 16:24:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.508 uVs 16:24:10 Integrated Voltage Measurement... 16:24:19 Voltage Offset Correction: v_off_ini = -240.614 uV, v_off_fin = -221.362 uV 16:24:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.307 uVs 16:24:19 Integrated Voltage Measurement... 16:24:28 Voltage Offset Correction: v_off_ini = -230.015 uV, v_off_fin = -241.195 uV 16:24:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.243 uVs 16:24:28 Integrated Voltage Measurement... 16:24:37 Voltage Offset Correction: v_off_ini = -239.749 uV, v_off_fin = -236.256 uV 16:24:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.087 uVs 16:24:37 Integrated Voltage Measurement... 16:24:46 Voltage Offset Correction: v_off_ini = -228.718 uV, v_off_fin = -221.658 uV 16:24:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.039 uVs 16:24:46 Integrated Voltage Measurement... 16:24:55 Voltage Offset Correction: v_off_ini = -220.001 uV, v_off_fin = -212.671 uV 16:24:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.292 uVs 16:24:59 I1X Average and RMS of Measurements VT = -144.913 +- 7.453 uVs I1X = 28.984 +- 1.491 uTm 16:25:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:06 Integrated Voltage Measurement... 16:25:15 Voltage Offset Correction: v_off_ini = -223.488 uV, v_off_fin = -222.003 uV 16:25:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.429 uVs 16:25:15 Integrated Voltage Measurement... 16:25:24 Voltage Offset Correction: v_off_ini = -212.185 uV, v_off_fin = -201.918 uV 16:25:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.263 uVs 16:25:24 Integrated Voltage Measurement... 16:25:33 Voltage Offset Correction: v_off_ini = -207.758 uV, v_off_fin = -224.161 uV 16:25:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.308 uVs 16:25:33 Integrated Voltage Measurement... 16:25:42 Voltage Offset Correction: v_off_ini = -219.550 uV, v_off_fin = -202.563 uV 16:25:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.120 uVs 16:25:42 Integrated Voltage Measurement... 16:25:51 Voltage Offset Correction: v_off_ini = -208.584 uV, v_off_fin = -229.727 uV 16:25:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.882 uVs 16:25:51 Integrated Voltage Measurement... 16:26:00 Voltage Offset Correction: v_off_ini = -220.285 uV, v_off_fin = -205.739 uV 16:26:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.778 uVs 16:26:04 I1Y Average and RMS of Measurements VT = -249.463 +- 4.212 uVs I1Y = -49.893 +- 0.842 uTm 16:26:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = -227.565 uV, v_off_fin = -219.271 uV 16:26:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.495 uVs 16:26:21 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = -223.008 uV, v_off_fin = -207.696 uV 16:26:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.791 uVs 16:26:30 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = -214.112 uV, v_off_fin = -221.681 uV 16:26:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.151 uVs 16:26:39 Integrated Voltage Measurement... 16:26:48 Voltage Offset Correction: v_off_ini = -205.175 uV, v_off_fin = -205.150 uV 16:26:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.895 uVs 16:26:48 Integrated Voltage Measurement... 16:26:57 Voltage Offset Correction: v_off_ini = -210.861 uV, v_off_fin = -217.513 uV 16:26:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.040 uVs 16:26:57 Integrated Voltage Measurement... 16:27:06 Voltage Offset Correction: v_off_ini = -215.030 uV, v_off_fin = -214.082 uV 16:27:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.230 uVs 16:27:08 I2X Average and RMS of Measurements VT = -146.934 +- 5.684 uVs I2X = 13.518 +- 0.523 uTm^2 16:27:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:16 Integrated Voltage Measurement... 16:27:25 Voltage Offset Correction: v_off_ini = -215.058 uV, v_off_fin = -226.782 uV 16:27:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -489.524 uVs 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = -198.963 uV, v_off_fin = -210.322 uV 16:27:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.433 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = -206.231 uV, v_off_fin = -220.568 uV 16:27:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.409 uVs 16:27:43 Integrated Voltage Measurement... 16:27:52 Voltage Offset Correction: v_off_ini = -211.005 uV, v_off_fin = -206.550 uV 16:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 493.695 uVs 16:27:52 Integrated Voltage Measurement... 16:28:01 Voltage Offset Correction: v_off_ini = -227.475 uV, v_off_fin = -209.305 uV 16:28:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -474.485 uVs 16:28:01 Integrated Voltage Measurement... 16:28:10 Voltage Offset Correction: v_off_ini = -206.472 uV, v_off_fin = -209.824 uV 16:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.134 uVs 16:28:12 I2Y Average and RMS of Measurements VT = -486.113 +- 5.167 uVs I2Y = -44.722 +- 0.475 uTm^2 16:28:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:27 Integrated Voltage Measurement... 16:28:36 Voltage Offset Correction: v_off_ini = -213.553 uV, v_off_fin = -217.890 uV 16:28:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.262 uVs 16:28:36 Integrated Voltage Measurement... 16:28:45 Voltage Offset Correction: v_off_ini = -208.314 uV, v_off_fin = -201.557 uV 16:28:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.366 uVs 16:28:45 Integrated Voltage Measurement... 16:28:54 Voltage Offset Correction: v_off_ini = -207.875 uV, v_off_fin = -202.888 uV 16:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.055 uVs 16:28:54 Integrated Voltage Measurement... 16:29:03 Voltage Offset Correction: v_off_ini = -206.515 uV, v_off_fin = -200.183 uV 16:29:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.399 uVs 16:29:03 Integrated Voltage Measurement... 16:29:12 Voltage Offset Correction: v_off_ini = -205.037 uV, v_off_fin = -204.998 uV 16:29:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.814 uVs 16:29:12 Integrated Voltage Measurement... 16:29:21 Voltage Offset Correction: v_off_ini = -197.288 uV, v_off_fin = -193.406 uV 16:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.511 uVs 16:29:25 I1X Average and RMS of Measurements VT = -138.568 +- 4.081 uVs I1X = 27.714 +- 0.816 uTm 16:29:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:32 Integrated Voltage Measurement... 16:29:41 Voltage Offset Correction: v_off_ini = -216.913 uV, v_off_fin = -211.862 uV 16:29:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.508 uVs 16:29:41 Integrated Voltage Measurement... 16:29:50 Voltage Offset Correction: v_off_ini = -210.176 uV, v_off_fin = -198.302 uV 16:29:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.092 uVs 16:29:50 Integrated Voltage Measurement... 16:29:59 Voltage Offset Correction: v_off_ini = -204.334 uV, v_off_fin = -215.088 uV 16:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.569 uVs 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = -205.385 uV, v_off_fin = -201.199 uV 16:30:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.363 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = -206.356 uV, v_off_fin = -208.342 uV 16:30:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.764 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = -207.504 uV, v_off_fin = -200.759 uV 16:30:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.947 uVs 16:30:30 I1Y Average and RMS of Measurements VT = -237.041 +- 1.368 uVs I1Y = -47.408 +- 0.274 uTm 16:30:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:38 Integrated Voltage Measurement... 16:30:47 Voltage Offset Correction: v_off_ini = -193.721 uV, v_off_fin = -206.280 uV 16:30:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.777 uVs 16:30:47 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = -194.742 uV, v_off_fin = -205.870 uV 16:30:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.936 uVs 16:30:56 Integrated Voltage Measurement... 16:31:05 Voltage Offset Correction: v_off_ini = -215.179 uV, v_off_fin = -229.214 uV 16:31:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.640 uVs 16:31:05 Integrated Voltage Measurement... 16:31:14 Voltage Offset Correction: v_off_ini = -198.083 uV, v_off_fin = -184.673 uV 16:31:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.171 uVs 16:31:14 Integrated Voltage Measurement... 16:31:23 Voltage Offset Correction: v_off_ini = -200.421 uV, v_off_fin = -207.756 uV 16:31:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.852 uVs 16:31:23 Integrated Voltage Measurement... 16:31:32 Voltage Offset Correction: v_off_ini = -184.965 uV, v_off_fin = -181.660 uV 16:31:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.967 uVs 16:31:34 I2X Average and RMS of Measurements VT = -146.891 +- 9.884 uVs I2X = 13.514 +- 0.909 uTm^2 16:31:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:42 Integrated Voltage Measurement... 16:31:51 Voltage Offset Correction: v_off_ini = -179.652 uV, v_off_fin = -174.076 uV 16:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -466.193 uVs 16:31:51 Integrated Voltage Measurement... 16:32:00 Voltage Offset Correction: v_off_ini = -160.868 uV, v_off_fin = -167.794 uV 16:32:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.192 uVs 16:32:00 Integrated Voltage Measurement... 16:32:09 Voltage Offset Correction: v_off_ini = -169.485 uV, v_off_fin = -165.393 uV 16:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -491.727 uVs 16:32:09 Integrated Voltage Measurement... 16:32:18 Voltage Offset Correction: v_off_ini = -176.272 uV, v_off_fin = -157.097 uV 16:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.655 uVs 16:32:18 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = -176.266 uV, v_off_fin = -167.916 uV 16:32:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -492.315 uVs 16:32:27 Integrated Voltage Measurement... 16:32:36 Voltage Offset Correction: v_off_ini = -158.911 uV, v_off_fin = -163.873 uV 16:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.121 uVs 16:32:38 I2Y Average and RMS of Measurements VT = -481.367 +- 6.205 uVs I2Y = -44.286 +- 0.571 uTm^2 16:32:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:53 Integrated Voltage Measurement... 16:33:02 Voltage Offset Correction: v_off_ini = -157.551 uV, v_off_fin = -162.295 uV 16:33:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.268 uVs 16:33:02 Integrated Voltage Measurement... 16:33:11 Voltage Offset Correction: v_off_ini = -141.107 uV, v_off_fin = -144.595 uV 16:33:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.720 uVs 16:33:11 Integrated Voltage Measurement... 16:33:20 Voltage Offset Correction: v_off_ini = -154.757 uV, v_off_fin = -148.216 uV 16:33:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.121 uVs 16:33:20 Integrated Voltage Measurement... 16:33:29 Voltage Offset Correction: v_off_ini = -150.950 uV, v_off_fin = -136.730 uV 16:33:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.824 uVs 16:33:29 Integrated Voltage Measurement... 16:33:38 Voltage Offset Correction: v_off_ini = -129.500 uV, v_off_fin = -134.822 uV 16:33:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.684 uVs 16:33:38 Integrated Voltage Measurement... 16:33:47 Voltage Offset Correction: v_off_ini = -145.942 uV, v_off_fin = -138.958 uV 16:33:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.053 uVs 16:33:52 I1X Average and RMS of Measurements VT = -127.111 +- 2.604 uVs I1X = 25.422 +- 0.521 uTm 16:33:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:58 Integrated Voltage Measurement... 16:34:07 Voltage Offset Correction: v_off_ini = -143.662 uV, v_off_fin = -141.029 uV 16:34:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.859 uVs 16:34:07 Integrated Voltage Measurement... 16:34:16 Voltage Offset Correction: v_off_ini = -140.921 uV, v_off_fin = -129.548 uV 16:34:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.922 uVs 16:34:16 Integrated Voltage Measurement... 16:34:25 Voltage Offset Correction: v_off_ini = -143.417 uV, v_off_fin = -139.969 uV 16:34:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.541 uVs 16:34:25 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = -103.822 uV, v_off_fin = -107.192 uV 16:34:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.965 uVs 16:34:34 Integrated Voltage Measurement... 16:34:43 Voltage Offset Correction: v_off_ini = -115.078 uV, v_off_fin = -131.199 uV 16:34:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.144 uVs 16:34:43 Integrated Voltage Measurement... 16:34:52 Voltage Offset Correction: v_off_ini = -119.868 uV, v_off_fin = -110.898 uV 16:34:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.673 uVs 16:34:56 I1Y Average and RMS of Measurements VT = -229.684 +- 8.472 uVs I1Y = -45.937 +- 1.694 uTm 16:35:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:04 Integrated Voltage Measurement... 16:35:13 Voltage Offset Correction: v_off_ini = -133.668 uV, v_off_fin = -139.446 uV 16:35:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.597 uVs 16:35:13 Integrated Voltage Measurement... 16:35:22 Voltage Offset Correction: v_off_ini = -138.620 uV, v_off_fin = -129.369 uV 16:35:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.878 uVs 16:35:22 Integrated Voltage Measurement... 16:35:31 Voltage Offset Correction: v_off_ini = -142.631 uV, v_off_fin = -148.591 uV 16:35:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.261 uVs 16:35:31 Integrated Voltage Measurement... 16:35:40 Voltage Offset Correction: v_off_ini = -128.419 uV, v_off_fin = -114.454 uV 16:35:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.771 uVs 16:35:40 Integrated Voltage Measurement... 16:35:49 Voltage Offset Correction: v_off_ini = -122.462 uV, v_off_fin = -135.249 uV 16:35:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -123.188 uVs 16:35:49 Integrated Voltage Measurement... 16:35:58 Voltage Offset Correction: v_off_ini = -126.011 uV, v_off_fin = -113.795 uV 16:35:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.269 uVs 16:36:01 I2X Average and RMS of Measurements VT = -137.494 +- 3.426 uVs I2X = 12.650 +- 0.315 uTm^2 16:36:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:08 Integrated Voltage Measurement... 16:36:17 Voltage Offset Correction: v_off_ini = -126.190 uV, v_off_fin = -126.939 uV 16:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.887 uVs 16:36:17 Integrated Voltage Measurement... 16:36:26 Voltage Offset Correction: v_off_ini = -119.321 uV, v_off_fin = -136.557 uV 16:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.487 uVs 16:36:26 Integrated Voltage Measurement... 16:36:35 Voltage Offset Correction: v_off_ini = -125.667 uV, v_off_fin = -120.751 uV 16:36:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.261 uVs 16:36:35 Integrated Voltage Measurement... 16:36:44 Voltage Offset Correction: v_off_ini = -135.065 uV, v_off_fin = -131.582 uV 16:36:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.393 uVs 16:36:44 Integrated Voltage Measurement... 16:36:53 Voltage Offset Correction: v_off_ini = -140.152 uV, v_off_fin = -132.000 uV 16:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.629 uVs 16:36:53 Integrated Voltage Measurement... 16:37:02 Voltage Offset Correction: v_off_ini = -122.208 uV, v_off_fin = -125.378 uV 16:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.669 uVs 16:37:05 I2Y Average and RMS of Measurements VT = -465.888 +- 2.305 uVs I2Y = -42.862 +- 0.212 uTm^2 16:37:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:20 Integrated Voltage Measurement... 16:37:29 Voltage Offset Correction: v_off_ini = -122.911 uV, v_off_fin = -134.948 uV 16:37:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.916 uVs 16:37:29 Integrated Voltage Measurement... 16:37:38 Voltage Offset Correction: v_off_ini = -133.977 uV, v_off_fin = -108.318 uV 16:37:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 114.033 uVs 16:37:38 Integrated Voltage Measurement... 16:37:47 Voltage Offset Correction: v_off_ini = -106.656 uV, v_off_fin = -125.930 uV 16:37:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.801 uVs 16:37:47 Integrated Voltage Measurement... 16:37:56 Voltage Offset Correction: v_off_ini = -126.899 uV, v_off_fin = -118.534 uV 16:37:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.978 uVs 16:37:56 Integrated Voltage Measurement... 16:38:05 Voltage Offset Correction: v_off_ini = -102.551 uV, v_off_fin = -115.770 uV 16:38:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.538 uVs 16:38:05 Integrated Voltage Measurement... 16:38:14 Voltage Offset Correction: v_off_ini = -120.889 uV, v_off_fin = -120.213 uV 16:38:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.688 uVs 16:38:18 I1X Average and RMS of Measurements VT = -127.992 +- 3.622 uVs I1X = 25.600 +- 0.723 uTm 16:38:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:25 Integrated Voltage Measurement... 16:38:34 Voltage Offset Correction: v_off_ini = -117.127 uV, v_off_fin = -119.469 uV 16:38:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.222 uVs 16:38:34 Integrated Voltage Measurement... 16:38:43 Voltage Offset Correction: v_off_ini = -113.009 uV, v_off_fin = -80.810 uV 16:38:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.934 uVs 16:38:43 Integrated Voltage Measurement... 16:38:52 Voltage Offset Correction: v_off_ini = -113.182 uV, v_off_fin = -121.310 uV 16:38:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.917 uVs 16:38:52 Integrated Voltage Measurement... 16:39:01 Voltage Offset Correction: v_off_ini = -108.615 uV, v_off_fin = -100.581 uV 16:39:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 236.519 uVs 16:39:01 Integrated Voltage Measurement... 16:39:10 Voltage Offset Correction: v_off_ini = -115.594 uV, v_off_fin = -109.995 uV 16:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.486 uVs 16:39:10 Integrated Voltage Measurement... 16:39:19 Voltage Offset Correction: v_off_ini = -94.202 uV, v_off_fin = -76.015 uV 16:39:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.243 uVs 16:39:23 I1Y Average and RMS of Measurements VT = -224.554 +- 1.988 uVs I1Y = -44.907 +- 0.399 uTm 16:39:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:30 Integrated Voltage Measurement... 16:39:39 Voltage Offset Correction: v_off_ini = -82.744 uV, v_off_fin = -93.932 uV 16:39:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.775 uVs 16:39:39 Integrated Voltage Measurement... 16:39:48 Voltage Offset Correction: v_off_ini = -81.195 uV, v_off_fin = -97.048 uV 16:39:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.352 uVs 16:39:49 Integrated Voltage Measurement... 16:39:57 Voltage Offset Correction: v_off_ini = -98.629 uV, v_off_fin = -111.395 uV 16:39:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.441 uVs 16:39:58 Integrated Voltage Measurement... 16:40:06 Voltage Offset Correction: v_off_ini = -102.502 uV, v_off_fin = -85.844 uV 16:40:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.078 uVs 16:40:07 Integrated Voltage Measurement... 16:40:16 Voltage Offset Correction: v_off_ini = -88.228 uV, v_off_fin = -98.482 uV 16:40:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.450 uVs 16:40:16 Integrated Voltage Measurement... 16:40:25 Voltage Offset Correction: v_off_ini = -64.979 uV, v_off_fin = -75.813 uV 16:40:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.712 uVs 16:40:27 I2X Average and RMS of Measurements VT = -123.468 +- 3.487 uVs I2X = 11.359 +- 0.321 uTm^2 16:40:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:35 Integrated Voltage Measurement... 16:40:44 Voltage Offset Correction: v_off_ini = -82.064 uV, v_off_fin = -80.365 uV 16:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.056 uVs 16:40:44 Integrated Voltage Measurement... 16:40:53 Voltage Offset Correction: v_off_ini = -80.892 uV, v_off_fin = -80.793 uV 16:40:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.719 uVs 16:40:53 Integrated Voltage Measurement... 16:41:02 Voltage Offset Correction: v_off_ini = -83.055 uV, v_off_fin = -85.681 uV 16:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.595 uVs 16:41:02 Integrated Voltage Measurement... 16:41:11 Voltage Offset Correction: v_off_ini = -82.448 uV, v_off_fin = -79.234 uV 16:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 466.289 uVs 16:41:11 Integrated Voltage Measurement... 16:41:20 Voltage Offset Correction: v_off_ini = -75.890 uV, v_off_fin = -78.615 uV 16:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.227 uVs 16:41:20 Integrated Voltage Measurement... 16:41:29 Voltage Offset Correction: v_off_ini = -101.386 uV, v_off_fin = -81.918 uV 16:41:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.419 uVs 16:41:31 I2Y Average and RMS of Measurements VT = -457.384 +- 3.195 uVs I2Y = -42.079 +- 0.294 uTm^2 16:41:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:46 Integrated Voltage Measurement... 16:41:55 Voltage Offset Correction: v_off_ini = -74.668 uV, v_off_fin = -78.793 uV 16:41:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -114.844 uVs 16:41:55 Integrated Voltage Measurement... 16:42:04 Voltage Offset Correction: v_off_ini = -64.451 uV, v_off_fin = -61.015 uV 16:42:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.078 uVs 16:42:04 Integrated Voltage Measurement... 16:42:13 Voltage Offset Correction: v_off_ini = -65.412 uV, v_off_fin = -68.142 uV 16:42:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.060 uVs 16:42:13 Integrated Voltage Measurement... 16:42:22 Voltage Offset Correction: v_off_ini = -76.597 uV, v_off_fin = -65.913 uV 16:42:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.708 uVs 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = -72.965 uV, v_off_fin = -76.903 uV 16:42:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.860 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = -70.539 uV, v_off_fin = -69.406 uV 16:42:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.923 uVs 16:42:44 I1X Average and RMS of Measurements VT = -112.579 +- 7.879 uVs I1X = 22.517 +- 1.578 uTm 16:42:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:51 Integrated Voltage Measurement... 16:43:00 Voltage Offset Correction: v_off_ini = -59.636 uV, v_off_fin = -65.608 uV 16:43:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.327 uVs 16:43:00 Integrated Voltage Measurement... 16:43:09 Voltage Offset Correction: v_off_ini = -64.693 uV, v_off_fin = -45.650 uV 16:43:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.497 uVs 16:43:09 Integrated Voltage Measurement... 16:43:18 Voltage Offset Correction: v_off_ini = -60.277 uV, v_off_fin = -69.541 uV 16:43:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.180 uVs 16:43:18 Integrated Voltage Measurement... 16:43:27 Voltage Offset Correction: v_off_ini = -65.840 uV, v_off_fin = -52.455 uV 16:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.900 uVs 16:43:27 Integrated Voltage Measurement... 16:43:36 Voltage Offset Correction: v_off_ini = -64.202 uV, v_off_fin = -71.975 uV 16:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.367 uVs 16:43:36 Integrated Voltage Measurement... 16:43:45 Voltage Offset Correction: v_off_ini = -66.546 uV, v_off_fin = -61.468 uV 16:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.326 uVs 16:43:49 I1Y Average and RMS of Measurements VT = -217.099 +- 5.184 uVs I1Y = -43.420 +- 1.039 uTm 16:43:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:57 Integrated Voltage Measurement... 16:44:06 Voltage Offset Correction: v_off_ini = -76.244 uV, v_off_fin = -90.777 uV 16:44:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.526 uVs 16:44:06 Integrated Voltage Measurement... 16:44:15 Voltage Offset Correction: v_off_ini = -84.683 uV, v_off_fin = -69.436 uV 16:44:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.274 uVs 16:44:15 Integrated Voltage Measurement... 16:44:24 Voltage Offset Correction: v_off_ini = -75.789 uV, v_off_fin = -82.688 uV 16:44:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.299 uVs 16:44:24 Integrated Voltage Measurement... 16:44:33 Voltage Offset Correction: v_off_ini = -56.771 uV, v_off_fin = -52.759 uV 16:44:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.359 uVs 16:44:33 Integrated Voltage Measurement... 16:44:42 Voltage Offset Correction: v_off_ini = -52.958 uV, v_off_fin = -66.939 uV 16:44:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.483 uVs 16:44:42 Integrated Voltage Measurement... 16:44:51 Voltage Offset Correction: v_off_ini = -62.909 uV, v_off_fin = -46.047 uV 16:44:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.167 uVs 16:44:53 I2X Average and RMS of Measurements VT = -116.851 +- 7.840 uVs I2X = 10.750 +- 0.721 uTm^2 16:44:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:01 Integrated Voltage Measurement... 16:45:10 Voltage Offset Correction: v_off_ini = -57.675 uV, v_off_fin = -48.772 uV 16:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.890 uVs 16:45:10 Integrated Voltage Measurement... 16:45:19 Voltage Offset Correction: v_off_ini = -41.543 uV, v_off_fin = -43.355 uV 16:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.394 uVs 16:45:19 Integrated Voltage Measurement... 16:45:28 Voltage Offset Correction: v_off_ini = -41.605 uV, v_off_fin = -35.538 uV 16:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.547 uVs 16:45:28 Integrated Voltage Measurement... 16:45:37 Voltage Offset Correction: v_off_ini = -39.472 uV, v_off_fin = -44.492 uV 16:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 434.853 uVs 16:45:37 Integrated Voltage Measurement... 16:45:46 Voltage Offset Correction: v_off_ini = -44.825 uV, v_off_fin = -44.068 uV 16:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.023 uVs 16:45:46 Integrated Voltage Measurement... 16:45:55 Voltage Offset Correction: v_off_ini = -39.793 uV, v_off_fin = -32.529 uV 16:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 442.415 uVs 16:45:58 I2Y Average and RMS of Measurements VT = -439.187 +- 4.987 uVs I2Y = -40.405 +- 0.459 uTm^2 16:46:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:13 Integrated Voltage Measurement... 16:46:22 Voltage Offset Correction: v_off_ini = -18.050 uV, v_off_fin = -14.283 uV 16:46:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.847 uVs 16:46:22 Integrated Voltage Measurement... 16:46:31 Voltage Offset Correction: v_off_ini = -24.286 uV, v_off_fin = -29.190 uV 16:46:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.187 uVs 16:46:31 Integrated Voltage Measurement... 16:46:40 Voltage Offset Correction: v_off_ini = -46.315 uV, v_off_fin = -36.877 uV 16:46:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.167 uVs 16:46:40 Integrated Voltage Measurement... 16:46:49 Voltage Offset Correction: v_off_ini = -20.147 uV, v_off_fin = -22.535 uV 16:46:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.750 uVs 16:46:49 Integrated Voltage Measurement... 16:46:58 Voltage Offset Correction: v_off_ini = -27.239 uV, v_off_fin = -28.451 uV 16:46:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.366 uVs 16:46:58 Integrated Voltage Measurement... 16:47:07 Voltage Offset Correction: v_off_ini = -41.256 uV, v_off_fin = -32.699 uV 16:47:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.164 uVs 16:47:11 I1X Average and RMS of Measurements VT = -100.913 +- 3.234 uVs I1X = 20.183 +- 0.647 uTm 16:47:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:18 Integrated Voltage Measurement... 16:47:27 Voltage Offset Correction: v_off_ini = -38.383 uV, v_off_fin = -53.309 uV 16:47:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.390 uVs 16:47:27 Integrated Voltage Measurement... 16:47:36 Voltage Offset Correction: v_off_ini = -31.817 uV, v_off_fin = -23.107 uV 16:47:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.534 uVs 16:47:36 Integrated Voltage Measurement... 16:47:45 Voltage Offset Correction: v_off_ini = -22.506 uV, v_off_fin = -47.279 uV 16:47:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.451 uVs 16:47:45 Integrated Voltage Measurement... 16:47:53 Voltage Offset Correction: v_off_ini = -43.191 uV, v_off_fin = -33.641 uV 16:47:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.312 uVs 16:47:54 Integrated Voltage Measurement... 16:48:02 Voltage Offset Correction: v_off_ini = -39.785 uV, v_off_fin = -46.586 uV 16:48:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.550 uVs 16:48:03 Integrated Voltage Measurement... 16:48:11 Voltage Offset Correction: v_off_ini = -24.256 uV, v_off_fin = -5.112 uV 16:48:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.429 uVs 16:48:16 I1Y Average and RMS of Measurements VT = -218.278 +- 5.009 uVs I1Y = -43.654 +- 1.001 uTm 16:48:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:23 Integrated Voltage Measurement... 16:48:32 Voltage Offset Correction: v_off_ini = -23.396 uV, v_off_fin = -40.206 uV 16:48:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.941 uVs 16:48:32 Integrated Voltage Measurement... 16:48:41 Voltage Offset Correction: v_off_ini = -28.180 uV, v_off_fin = -30.286 uV 16:48:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.932 uVs 16:48:41 Integrated Voltage Measurement... 16:48:50 Voltage Offset Correction: v_off_ini = -27.022 uV, v_off_fin = -40.481 uV 16:48:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.435 uVs 16:48:51 Integrated Voltage Measurement... 16:48:59 Voltage Offset Correction: v_off_ini = -31.209 uV, v_off_fin = -12.810 uV 16:49:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.899 uVs 16:49:00 Integrated Voltage Measurement... 16:49:09 Voltage Offset Correction: v_off_ini = -12.363 uV, v_off_fin = -33.428 uV 16:49:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.611 uVs 16:49:09 Integrated Voltage Measurement... 16:49:18 Voltage Offset Correction: v_off_ini = -23.409 uV, v_off_fin = -11.001 uV 16:49:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.218 uVs 16:49:20 I2X Average and RMS of Measurements VT = -103.173 +- 5.279 uVs I2X = 9.492 +- 0.486 uTm^2 16:49:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:28 Integrated Voltage Measurement... 16:49:37 Voltage Offset Correction: v_off_ini = -25.152 uV, v_off_fin = -22.948 uV 16:49:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.944 uVs 16:49:37 Integrated Voltage Measurement... 16:49:46 Voltage Offset Correction: v_off_ini = 0.361 uV, v_off_fin = -12.168 uV 16:49:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 427.402 uVs 16:49:46 Integrated Voltage Measurement... 16:49:55 Voltage Offset Correction: v_off_ini = -10.441 uV, v_off_fin = -20.311 uV 16:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.881 uVs 16:49:55 Integrated Voltage Measurement... 16:50:04 Voltage Offset Correction: v_off_ini = -26.050 uV, v_off_fin = -23.492 uV 16:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 426.894 uVs 16:50:04 Integrated Voltage Measurement... 16:50:13 Voltage Offset Correction: v_off_ini = -13.016 uV, v_off_fin = -24.348 uV 16:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -422.335 uVs 16:50:13 Integrated Voltage Measurement... 16:50:22 Voltage Offset Correction: v_off_ini = -12.008 uV, v_off_fin = -25.851 uV 16:50:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 429.939 uVs 16:50:24 I2Y Average and RMS of Measurements VT = -426.899 +- 0.906 uVs I2Y = -39.275 +- 0.083 uTm^2 16:50:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:39 Integrated Voltage Measurement... 16:50:48 Voltage Offset Correction: v_off_ini = -22.365 uV, v_off_fin = -10.786 uV 16:50:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.370 uVs 16:50:48 Integrated Voltage Measurement... 16:50:57 Voltage Offset Correction: v_off_ini = -14.587 uV, v_off_fin = -20.944 uV 16:50:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.481 uVs 16:50:57 Integrated Voltage Measurement... 16:51:06 Voltage Offset Correction: v_off_ini = 0.136 uV, v_off_fin = -10.094 uV 16:51:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.033 uVs 16:51:06 Integrated Voltage Measurement... 16:51:15 Voltage Offset Correction: v_off_ini = 4.249 uV, v_off_fin = -4.943 uV 16:51:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.362 uVs 16:51:15 Integrated Voltage Measurement... 16:51:24 Voltage Offset Correction: v_off_ini = 13.227 uV, v_off_fin = 2.255 uV 16:51:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.137 uVs 16:51:24 Integrated Voltage Measurement... 16:51:33 Voltage Offset Correction: v_off_ini = -9.714 uV, v_off_fin = -2.605 uV 16:51:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 101.152 uVs 16:51:37 I1X Average and RMS of Measurements VT = -101.756 +- 12.467 uVs I1X = 20.352 +- 2.494 uTm 16:51:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:44 Integrated Voltage Measurement... 16:51:53 Voltage Offset Correction: v_off_ini = 19.970 uV, v_off_fin = 5.276 uV 16:51:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -212.376 uVs 16:51:53 Integrated Voltage Measurement... 16:52:02 Voltage Offset Correction: v_off_ini = 19.898 uV, v_off_fin = 21.253 uV 16:52:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.955 uVs 16:52:02 Integrated Voltage Measurement... 16:52:11 Voltage Offset Correction: v_off_ini = 0.271 uV, v_off_fin = 0.991 uV 16:52:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.513 uVs 16:52:11 Integrated Voltage Measurement... 16:52:20 Voltage Offset Correction: v_off_ini = 9.459 uV, v_off_fin = 27.235 uV 16:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.524 uVs 16:52:20 Integrated Voltage Measurement... 16:52:29 Voltage Offset Correction: v_off_ini = 13.362 uV, v_off_fin = 8.524 uV 16:52:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.812 uVs 16:52:29 Integrated Voltage Measurement... 16:52:38 Voltage Offset Correction: v_off_ini = 9.830 uV, v_off_fin = 20.727 uV 16:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.148 uVs 16:52:42 I1Y Average and RMS of Measurements VT = -213.055 +- 1.651 uVs I1Y = -42.609 +- 0.329 uTm 16:52:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:50 Integrated Voltage Measurement... 16:52:59 Voltage Offset Correction: v_off_ini = 28.489 uV, v_off_fin = 5.774 uV 16:52:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -128.350 uVs 16:52:59 Integrated Voltage Measurement... 16:53:08 Voltage Offset Correction: v_off_ini = 5.561 uV, v_off_fin = 20.524 uV 16:53:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.452 uVs 16:53:08 Integrated Voltage Measurement... 16:53:17 Voltage Offset Correction: v_off_ini = 5.469 uV, v_off_fin = 7.026 uV 16:53:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -99.490 uVs 16:53:17 Integrated Voltage Measurement... 16:53:26 Voltage Offset Correction: v_off_ini = 26.439 uV, v_off_fin = 48.576 uV 16:53:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.488 uVs 16:53:26 Integrated Voltage Measurement... 16:53:35 Voltage Offset Correction: v_off_ini = 28.238 uV, v_off_fin = 26.196 uV 16:53:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.120 uVs 16:53:35 Integrated Voltage Measurement... 16:53:44 Voltage Offset Correction: v_off_ini = 11.794 uV, v_off_fin = 39.242 uV 16:53:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.799 uVs 16:53:46 I2X Average and RMS of Measurements VT = -107.783 +- 9.807 uVs I2X = 9.916 +- 0.902 uTm^2 16:53:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = 15.546 uV, v_off_fin = 21.307 uV 16:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -402.280 uVs 16:54:03 Integrated Voltage Measurement... 16:54:12 Voltage Offset Correction: v_off_ini = 24.231 uV, v_off_fin = 21.612 uV 16:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.683 uVs 16:54:12 Integrated Voltage Measurement... 16:54:21 Voltage Offset Correction: v_off_ini = 14.786 uV, v_off_fin = 30.746 uV 16:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -429.787 uVs 16:54:21 Integrated Voltage Measurement... 16:54:30 Voltage Offset Correction: v_off_ini = 40.260 uV, v_off_fin = 41.660 uV 16:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.756 uVs 16:54:30 Integrated Voltage Measurement... 16:54:39 Voltage Offset Correction: v_off_ini = 47.620 uV, v_off_fin = 57.808 uV 16:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.674 uVs 16:54:39 Integrated Voltage Measurement... 16:54:48 Voltage Offset Correction: v_off_ini = 50.323 uV, v_off_fin = 51.955 uV 16:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 433.357 uVs 16:54:51 I2Y Average and RMS of Measurements VT = -424.589 +- 3.606 uVs I2Y = -39.062 +- 0.332 uTm^2 16:55:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:06 Integrated Voltage Measurement... 16:55:15 Voltage Offset Correction: v_off_ini = 72.956 uV, v_off_fin = 74.636 uV 16:55:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -82.226 uVs 16:55:15 Integrated Voltage Measurement... 16:55:24 Voltage Offset Correction: v_off_ini = 46.730 uV, v_off_fin = 62.055 uV 16:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 86.456 uVs 16:55:24 Integrated Voltage Measurement... 16:55:33 Voltage Offset Correction: v_off_ini = 40.988 uV, v_off_fin = 49.488 uV 16:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.689 uVs 16:55:33 Integrated Voltage Measurement... 16:55:42 Voltage Offset Correction: v_off_ini = 52.210 uV, v_off_fin = 71.679 uV 16:55:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.005 uVs 16:55:42 Integrated Voltage Measurement... 16:55:51 Voltage Offset Correction: v_off_ini = 55.281 uV, v_off_fin = 48.048 uV 16:55:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.683 uVs 16:55:51 Integrated Voltage Measurement... 16:56:00 Voltage Offset Correction: v_off_ini = 57.521 uV, v_off_fin = 60.443 uV 16:56:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.007 uVs 16:56:04 I1X Average and RMS of Measurements VT = -99.344 +- 10.617 uVs I1X = 19.870 +- 2.122 uTm 16:56:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:11 Integrated Voltage Measurement... 16:56:20 Voltage Offset Correction: v_off_ini = 60.337 uV, v_off_fin = 60.211 uV 16:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.950 uVs 16:56:20 Integrated Voltage Measurement... 16:56:29 Voltage Offset Correction: v_off_ini = 69.542 uV, v_off_fin = 70.794 uV 16:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.854 uVs 16:56:29 Integrated Voltage Measurement... 16:56:38 Voltage Offset Correction: v_off_ini = 70.252 uV, v_off_fin = 43.886 uV 16:56:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.698 uVs 16:56:38 Integrated Voltage Measurement... 16:56:47 Voltage Offset Correction: v_off_ini = 50.445 uV, v_off_fin = 68.139 uV 16:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.335 uVs 16:56:47 Integrated Voltage Measurement... 16:56:56 Voltage Offset Correction: v_off_ini = 57.403 uV, v_off_fin = 43.126 uV 16:56:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.779 uVs 16:56:56 Integrated Voltage Measurement... 16:57:05 Voltage Offset Correction: v_off_ini = 66.338 uV, v_off_fin = 76.012 uV 16:57:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.383 uVs 16:57:09 I1Y Average and RMS of Measurements VT = -206.500 +- 3.977 uVs I1Y = -41.299 +- 0.795 uTm 16:57:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:16 Integrated Voltage Measurement... 16:57:25 Voltage Offset Correction: v_off_ini = 61.541 uV, v_off_fin = 60.344 uV 16:57:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.002 uVs 16:57:25 Integrated Voltage Measurement... 16:57:34 Voltage Offset Correction: v_off_ini = 78.630 uV, v_off_fin = 100.415 uV 16:57:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.311 uVs 16:57:35 Integrated Voltage Measurement... 16:57:43 Voltage Offset Correction: v_off_ini = 93.812 uV, v_off_fin = 66.595 uV 16:57:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.056 uVs 16:57:44 Integrated Voltage Measurement... 16:57:52 Voltage Offset Correction: v_off_ini = 69.702 uV, v_off_fin = 80.161 uV 16:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.450 uVs 16:57:53 Integrated Voltage Measurement... 16:58:02 Voltage Offset Correction: v_off_ini = 65.015 uV, v_off_fin = 73.235 uV 16:58:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.843 uVs 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = 88.217 uV, v_off_fin = 98.074 uV 16:58:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.573 uVs 16:58:13 I2X Average and RMS of Measurements VT = -98.706 +- 3.222 uVs I2X = 9.081 +- 0.296 uTm^2 16:58:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:21 Integrated Voltage Measurement... 16:58:30 Voltage Offset Correction: v_off_ini = 84.876 uV, v_off_fin = 99.469 uV 16:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -418.547 uVs 16:58:30 Integrated Voltage Measurement... 16:58:39 Voltage Offset Correction: v_off_ini = 95.656 uV, v_off_fin = 94.443 uV 16:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 420.705 uVs 16:58:39 Integrated Voltage Measurement... 16:58:48 Voltage Offset Correction: v_off_ini = 80.256 uV, v_off_fin = 87.022 uV 16:58:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -412.433 uVs 16:58:48 Integrated Voltage Measurement... 16:58:57 Voltage Offset Correction: v_off_ini = 85.127 uV, v_off_fin = 100.658 uV 16:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.176 uVs 16:58:57 Integrated Voltage Measurement... 16:59:06 Voltage Offset Correction: v_off_ini = 92.759 uV, v_off_fin = 87.945 uV 16:59:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.763 uVs 16:59:06 Integrated Voltage Measurement... 16:59:15 Voltage Offset Correction: v_off_ini = 99.428 uV, v_off_fin = 85.911 uV 16:59:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.383 uVs 16:59:17 I2Y Average and RMS of Measurements VT = -418.668 +- 3.243 uVs I2Y = -38.517 +- 0.298 uTm^2 16:59:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:32 Integrated Voltage Measurement... 16:59:41 Voltage Offset Correction: v_off_ini = 105.181 uV, v_off_fin = 87.763 uV 16:59:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.610 uVs 16:59:41 Integrated Voltage Measurement... 16:59:50 Voltage Offset Correction: v_off_ini = 101.198 uV, v_off_fin = 99.025 uV 16:59:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.889 uVs 16:59:50 Integrated Voltage Measurement... 16:59:59 Voltage Offset Correction: v_off_ini = 81.383 uV, v_off_fin = 84.293 uV 16:59:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.811 uVs 16:59:59 Integrated Voltage Measurement... 17:00:08 Voltage Offset Correction: v_off_ini = 96.730 uV, v_off_fin = 88.801 uV 17:00:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.497 uVs 17:00:08 Integrated Voltage Measurement... 17:00:17 Voltage Offset Correction: v_off_ini = 93.572 uV, v_off_fin = 81.689 uV 17:00:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.922 uVs 17:00:17 Integrated Voltage Measurement... 17:00:26 Voltage Offset Correction: v_off_ini = 83.428 uV, v_off_fin = 94.501 uV 17:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.619 uVs 17:00:30 I1X Average and RMS of Measurements VT = -98.225 +- 4.978 uVs I1X = 19.645 +- 0.996 uTm 17:00:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:37 Integrated Voltage Measurement... 17:00:46 Voltage Offset Correction: v_off_ini = 100.372 uV, v_off_fin = 93.794 uV 17:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.730 uVs 17:00:46 Integrated Voltage Measurement... 17:00:55 Voltage Offset Correction: v_off_ini = 87.496 uV, v_off_fin = 97.117 uV 17:00:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.449 uVs 17:00:55 Integrated Voltage Measurement... 17:01:04 Voltage Offset Correction: v_off_ini = 72.939 uV, v_off_fin = 71.620 uV 17:01:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.817 uVs 17:01:04 Integrated Voltage Measurement... 17:01:13 Voltage Offset Correction: v_off_ini = 92.564 uV, v_off_fin = 97.354 uV 17:01:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.272 uVs 17:01:13 Integrated Voltage Measurement... 17:01:22 Voltage Offset Correction: v_off_ini = 98.710 uV, v_off_fin = 89.861 uV 17:01:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.788 uVs 17:01:22 Integrated Voltage Measurement... 17:01:31 Voltage Offset Correction: v_off_ini = 114.804 uV, v_off_fin = 125.429 uV 17:01:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.053 uVs 17:01:35 I1Y Average and RMS of Measurements VT = -207.518 +- 6.829 uVs I1Y = -41.504 +- 1.365 uTm 17:01:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:43 Integrated Voltage Measurement... 17:01:52 Voltage Offset Correction: v_off_ini = 114.567 uV, v_off_fin = 108.484 uV 17:01:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.284 uVs 17:01:52 Integrated Voltage Measurement... 17:02:01 Voltage Offset Correction: v_off_ini = 109.396 uV, v_off_fin = 116.188 uV 17:02:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.190 uVs 17:02:01 Integrated Voltage Measurement... 17:02:10 Voltage Offset Correction: v_off_ini = 101.118 uV, v_off_fin = 98.140 uV 17:02:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.542 uVs 17:02:10 Integrated Voltage Measurement... 17:02:19 Voltage Offset Correction: v_off_ini = 100.877 uV, v_off_fin = 108.741 uV 17:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.106 uVs 17:02:19 Integrated Voltage Measurement... 17:02:28 Voltage Offset Correction: v_off_ini = 100.095 uV, v_off_fin = 96.393 uV 17:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.502 uVs 17:02:28 Integrated Voltage Measurement... 17:02:37 Voltage Offset Correction: v_off_ini = 102.290 uV, v_off_fin = 114.240 uV 17:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.483 uVs 17:02:39 I2X Average and RMS of Measurements VT = -89.518 +- 5.924 uVs I2X = 8.236 +- 0.545 uTm^2 17:02:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:47 Integrated Voltage Measurement... 17:02:56 Voltage Offset Correction: v_off_ini = 97.389 uV, v_off_fin = 119.669 uV 17:02:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -406.517 uVs 17:02:56 Integrated Voltage Measurement... 17:03:05 Voltage Offset Correction: v_off_ini = 105.352 uV, v_off_fin = 108.402 uV 17:03:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 403.304 uVs 17:03:05 Integrated Voltage Measurement... 17:03:14 Voltage Offset Correction: v_off_ini = 109.143 uV, v_off_fin = 85.316 uV 17:03:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -400.850 uVs 17:03:14 Integrated Voltage Measurement... 17:03:23 Voltage Offset Correction: v_off_ini = 96.335 uV, v_off_fin = 88.113 uV 17:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 414.870 uVs 17:03:23 Integrated Voltage Measurement... 17:03:32 Voltage Offset Correction: v_off_ini = 89.283 uV, v_off_fin = 95.387 uV 17:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.881 uVs 17:03:32 Integrated Voltage Measurement... 17:03:41 Voltage Offset Correction: v_off_ini = 95.755 uV, v_off_fin = 103.278 uV 17:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.623 uVs 17:03:44 I2Y Average and RMS of Measurements VT = -409.341 +- 4.350 uVs I2Y = -37.659 +- 0.400 uTm^2 17:03:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:59 Integrated Voltage Measurement... 17:04:08 Voltage Offset Correction: v_off_ini = 116.228 uV, v_off_fin = 110.905 uV 17:04:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.832 uVs 17:04:08 Integrated Voltage Measurement... 17:04:17 Voltage Offset Correction: v_off_ini = 98.779 uV, v_off_fin = 106.131 uV 17:04:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.908 uVs 17:04:17 Integrated Voltage Measurement... 17:04:26 Voltage Offset Correction: v_off_ini = 95.156 uV, v_off_fin = 97.800 uV 17:04:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.076 uVs 17:04:26 Integrated Voltage Measurement... 17:04:35 Voltage Offset Correction: v_off_ini = 112.604 uV, v_off_fin = 93.153 uV 17:04:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.700 uVs 17:04:35 Integrated Voltage Measurement... 17:04:44 Voltage Offset Correction: v_off_ini = 86.364 uV, v_off_fin = 88.924 uV 17:04:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.211 uVs 17:04:44 Integrated Voltage Measurement... 17:04:53 Voltage Offset Correction: v_off_ini = 97.782 uV, v_off_fin = 101.760 uV 17:04:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.614 uVs 17:04:57 I1X Average and RMS of Measurements VT = -93.057 +- 3.463 uVs I1X = 18.611 +- 0.693 uTm 17:04:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:04 Integrated Voltage Measurement... 17:05:13 Voltage Offset Correction: v_off_ini = 76.773 uV, v_off_fin = 76.276 uV 17:05:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -187.056 uVs 17:05:13 Integrated Voltage Measurement... 17:05:22 Voltage Offset Correction: v_off_ini = 79.402 uV, v_off_fin = 96.336 uV 17:05:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.356 uVs 17:05:22 Integrated Voltage Measurement... 17:05:31 Voltage Offset Correction: v_off_ini = 93.138 uV, v_off_fin = 81.059 uV 17:05:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -207.021 uVs 17:05:31 Integrated Voltage Measurement... 17:05:40 Voltage Offset Correction: v_off_ini = 96.436 uV, v_off_fin = 90.789 uV 17:05:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.252 uVs 17:05:40 Integrated Voltage Measurement... 17:05:49 Voltage Offset Correction: v_off_ini = 91.028 uV, v_off_fin = 67.325 uV 17:05:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.877 uVs 17:05:49 Integrated Voltage Measurement... 17:05:58 Voltage Offset Correction: v_off_ini = 83.325 uV, v_off_fin = 101.860 uV 17:05:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 224.051 uVs 17:06:02 I1Y Average and RMS of Measurements VT = -206.769 +- 9.404 uVs I1Y = -41.349 +- 1.877 uTm 17:06:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:10 Integrated Voltage Measurement... 17:06:19 Voltage Offset Correction: v_off_ini = 95.156 uV, v_off_fin = 70.932 uV 17:06:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.607 uVs 17:06:19 Integrated Voltage Measurement... 17:06:28 Voltage Offset Correction: v_off_ini = 97.425 uV, v_off_fin = 110.604 uV 17:06:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.129 uVs 17:06:28 Integrated Voltage Measurement... 17:06:37 Voltage Offset Correction: v_off_ini = 75.395 uV, v_off_fin = 74.228 uV 17:06:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.403 uVs 17:06:37 Integrated Voltage Measurement... 17:06:46 Voltage Offset Correction: v_off_ini = 87.311 uV, v_off_fin = 93.379 uV 17:06:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.198 uVs 17:06:46 Integrated Voltage Measurement... 17:06:55 Voltage Offset Correction: v_off_ini = 89.508 uV, v_off_fin = 74.873 uV 17:06:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.980 uVs 17:06:55 Integrated Voltage Measurement... 17:07:04 Voltage Offset Correction: v_off_ini = 85.695 uV, v_off_fin = 95.682 uV 17:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.328 uVs 17:07:06 I2X Average and RMS of Measurements VT = -83.941 +- 6.920 uVs I2X = 7.723 +- 0.637 uTm^2 17:07:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:14 Integrated Voltage Measurement... 17:07:23 Voltage Offset Correction: v_off_ini = 98.160 uV, v_off_fin = 97.761 uV 17:07:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.080 uVs 17:07:23 Integrated Voltage Measurement... 17:07:32 Voltage Offset Correction: v_off_ini = 109.193 uV, v_off_fin = 97.014 uV 17:07:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.686 uVs 17:07:32 Integrated Voltage Measurement... 17:07:41 Voltage Offset Correction: v_off_ini = 109.734 uV, v_off_fin = 101.977 uV 17:07:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.317 uVs 17:07:41 Integrated Voltage Measurement... 17:07:50 Voltage Offset Correction: v_off_ini = 85.258 uV, v_off_fin = 89.386 uV 17:07:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 413.976 uVs 17:07:50 Integrated Voltage Measurement... 17:07:59 Voltage Offset Correction: v_off_ini = 93.588 uV, v_off_fin = 87.203 uV 17:07:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -405.370 uVs 17:07:59 Integrated Voltage Measurement... 17:08:08 Voltage Offset Correction: v_off_ini = 99.248 uV, v_off_fin = 88.281 uV 17:08:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.106 uVs 17:08:10 I2Y Average and RMS of Measurements VT = -403.089 +- 9.771 uVs I2Y = -37.084 +- 0.899 uTm^2 17:08:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:26 Integrated Voltage Measurement... 17:08:35 Voltage Offset Correction: v_off_ini = 85.895 uV, v_off_fin = 102.064 uV 17:08:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.811 uVs 17:08:35 Integrated Voltage Measurement... 17:08:44 Voltage Offset Correction: v_off_ini = 107.636 uV, v_off_fin = 117.175 uV 17:08:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.289 uVs 17:08:44 Integrated Voltage Measurement... 17:08:53 Voltage Offset Correction: v_off_ini = 111.167 uV, v_off_fin = 93.272 uV 17:08:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.536 uVs 17:08:53 Integrated Voltage Measurement... 17:09:02 Voltage Offset Correction: v_off_ini = 89.160 uV, v_off_fin = 99.033 uV 17:09:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.045 uVs 17:09:02 Integrated Voltage Measurement... 17:09:11 Voltage Offset Correction: v_off_ini = 110.685 uV, v_off_fin = 98.456 uV 17:09:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.083 uVs 17:09:11 Integrated Voltage Measurement... 17:09:20 Voltage Offset Correction: v_off_ini = 109.857 uV, v_off_fin = 102.640 uV 17:09:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.735 uVs 17:09:25 I1X Average and RMS of Measurements VT = -80.083 +- 3.534 uVs I1X = 16.017 +- 0.706 uTm 17:09:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:31 Integrated Voltage Measurement... 17:09:40 Voltage Offset Correction: v_off_ini = 98.532 uV, v_off_fin = 92.645 uV 17:09:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.134 uVs 17:09:40 Integrated Voltage Measurement... 17:09:49 Voltage Offset Correction: v_off_ini = 101.327 uV, v_off_fin = 108.193 uV 17:09:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 208.501 uVs 17:09:49 Integrated Voltage Measurement... 17:09:58 Voltage Offset Correction: v_off_ini = 89.896 uV, v_off_fin = 91.814 uV 17:09:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -199.908 uVs 17:09:58 Integrated Voltage Measurement... 17:10:07 Voltage Offset Correction: v_off_ini = 100.552 uV, v_off_fin = 100.492 uV 17:10:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.061 uVs 17:10:07 Integrated Voltage Measurement... 17:10:16 Voltage Offset Correction: v_off_ini = 95.126 uV, v_off_fin = 82.720 uV 17:10:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -196.494 uVs 17:10:16 Integrated Voltage Measurement... 17:10:25 Voltage Offset Correction: v_off_ini = 93.032 uV, v_off_fin = 96.090 uV 17:10:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.780 uVs 17:10:30 I1Y Average and RMS of Measurements VT = -196.813 +- 4.248 uVs I1Y = -39.357 +- 0.848 uTm 17:10:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:37 Integrated Voltage Measurement... 17:10:46 Voltage Offset Correction: v_off_ini = 114.172 uV, v_off_fin = 106.207 uV 17:10:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -69.279 uVs 17:10:46 Integrated Voltage Measurement... 17:10:55 Voltage Offset Correction: v_off_ini = 100.016 uV, v_off_fin = 112.657 uV 17:10:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.710 uVs 17:10:55 Integrated Voltage Measurement... 17:11:04 Voltage Offset Correction: v_off_ini = 111.652 uV, v_off_fin = 96.805 uV 17:11:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.408 uVs 17:11:04 Integrated Voltage Measurement... 17:11:13 Voltage Offset Correction: v_off_ini = 118.201 uV, v_off_fin = 126.121 uV 17:11:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.308 uVs 17:11:13 Integrated Voltage Measurement... 17:11:22 Voltage Offset Correction: v_off_ini = 112.250 uV, v_off_fin = 102.994 uV 17:11:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.020 uVs 17:11:22 Integrated Voltage Measurement... 17:11:31 Voltage Offset Correction: v_off_ini = 111.017 uV, v_off_fin = 127.941 uV 17:11:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.728 uVs 17:11:34 I2X Average and RMS of Measurements VT = -81.409 +- 8.135 uVs I2X = 7.490 +- 0.748 uTm^2 17:11:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:41 Integrated Voltage Measurement... 17:11:50 Voltage Offset Correction: v_off_ini = 127.586 uV, v_off_fin = 123.750 uV 17:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.091 uVs 17:11:50 Integrated Voltage Measurement... 17:11:59 Voltage Offset Correction: v_off_ini = 127.490 uV, v_off_fin = 130.913 uV 17:11:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.126 uVs 17:12:00 Integrated Voltage Measurement... 17:12:08 Voltage Offset Correction: v_off_ini = 128.050 uV, v_off_fin = 118.001 uV 17:12:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.525 uVs 17:12:09 Integrated Voltage Measurement... 17:12:17 Voltage Offset Correction: v_off_ini = 127.933 uV, v_off_fin = 145.179 uV 17:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.644 uVs 17:12:18 Integrated Voltage Measurement... 17:12:27 Voltage Offset Correction: v_off_ini = 141.043 uV, v_off_fin = 132.617 uV 17:12:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.312 uVs 17:12:27 Integrated Voltage Measurement... 17:12:36 Voltage Offset Correction: v_off_ini = 127.951 uV, v_off_fin = 137.205 uV 17:12:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.518 uVs 17:12:38 I2Y Average and RMS of Measurements VT = -382.203 +- 9.275 uVs I2Y = -35.163 +- 0.853 uTm^2 17:12:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:54 Integrated Voltage Measurement... 17:13:03 Voltage Offset Correction: v_off_ini = 127.522 uV, v_off_fin = 124.073 uV 17:13:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.913 uVs 17:13:03 Integrated Voltage Measurement... 17:13:12 Voltage Offset Correction: v_off_ini = 131.926 uV, v_off_fin = 125.853 uV 17:13:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.211 uVs 17:13:12 Integrated Voltage Measurement... 17:13:21 Voltage Offset Correction: v_off_ini = 114.320 uV, v_off_fin = 118.584 uV 17:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.913 uVs 17:13:21 Integrated Voltage Measurement... 17:13:30 Voltage Offset Correction: v_off_ini = 126.084 uV, v_off_fin = 133.598 uV 17:13:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.230 uVs 17:13:30 Integrated Voltage Measurement... 17:13:39 Voltage Offset Correction: v_off_ini = 133.214 uV, v_off_fin = 113.700 uV 17:13:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.266 uVs 17:13:39 Integrated Voltage Measurement... 17:13:48 Voltage Offset Correction: v_off_ini = 142.525 uV, v_off_fin = 146.889 uV 17:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.537 uVs 17:13:52 I1X Average and RMS of Measurements VT = -70.845 +- 6.807 uVs I1X = 14.169 +- 1.361 uTm 17:13:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:59 Integrated Voltage Measurement... 17:14:08 Voltage Offset Correction: v_off_ini = 119.704 uV, v_off_fin = 109.656 uV 17:14:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.141 uVs 17:14:08 Integrated Voltage Measurement... 17:14:17 Voltage Offset Correction: v_off_ini = 116.713 uV, v_off_fin = 136.160 uV 17:14:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 196.672 uVs 17:14:17 Integrated Voltage Measurement... 17:14:26 Voltage Offset Correction: v_off_ini = 124.358 uV, v_off_fin = 107.703 uV 17:14:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -203.377 uVs 17:14:26 Integrated Voltage Measurement... 17:14:35 Voltage Offset Correction: v_off_ini = 129.719 uV, v_off_fin = 148.972 uV 17:14:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.524 uVs 17:14:35 Integrated Voltage Measurement... 17:14:44 Voltage Offset Correction: v_off_ini = 124.659 uV, v_off_fin = 116.218 uV 17:14:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -183.535 uVs 17:14:44 Integrated Voltage Measurement... 17:14:53 Voltage Offset Correction: v_off_ini = 128.596 uV, v_off_fin = 138.933 uV 17:14:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 205.254 uVs 17:14:57 I1Y Average and RMS of Measurements VT = -194.751 +- 5.331 uVs I1Y = -38.944 +- 1.065 uTm 17:15:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:15:05 Integrated Voltage Measurement... 17:15:14 Voltage Offset Correction: v_off_ini = 136.556 uV, v_off_fin = 128.286 uV 17:15:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.669 uVs 17:15:14 Integrated Voltage Measurement... 17:15:23 Voltage Offset Correction: v_off_ini = 136.041 uV, v_off_fin = 146.500 uV 17:15:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.335 uVs 17:15:23 Integrated Voltage Measurement... 17:15:32 Voltage Offset Correction: v_off_ini = 127.112 uV, v_off_fin = 124.984 uV 17:15:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.065 uVs 17:15:32 Integrated Voltage Measurement... 17:15:41 Voltage Offset Correction: v_off_ini = 145.942 uV, v_off_fin = 142.985 uV 17:15:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.623 uVs 17:15:41 Integrated Voltage Measurement... 17:15:50 Voltage Offset Correction: v_off_ini = 140.319 uV, v_off_fin = 135.179 uV 17:15:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.854 uVs 17:15:50 Integrated Voltage Measurement... 17:15:59 Voltage Offset Correction: v_off_ini = 150.557 uV, v_off_fin = 161.204 uV 17:15:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.856 uVs 17:16:01 I2X Average and RMS of Measurements VT = -74.234 +- 11.771 uVs I2X = 6.829 +- 1.083 uTm^2 17:16:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:09 Integrated Voltage Measurement... 17:16:18 Voltage Offset Correction: v_off_ini = 166.673 uV, v_off_fin = 158.821 uV 17:16:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.725 uVs 17:16:18 Integrated Voltage Measurement... 17:16:27 Voltage Offset Correction: v_off_ini = 155.682 uV, v_off_fin = 155.716 uV 17:16:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.910 uVs 17:16:27 Integrated Voltage Measurement... 17:16:36 Voltage Offset Correction: v_off_ini = 148.961 uV, v_off_fin = 148.916 uV 17:16:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.406 uVs 17:16:36 Integrated Voltage Measurement... 17:16:45 Voltage Offset Correction: v_off_ini = 147.837 uV, v_off_fin = 151.309 uV 17:16:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.093 uVs 17:16:45 Integrated Voltage Measurement... 17:16:54 Voltage Offset Correction: v_off_ini = 133.946 uV, v_off_fin = 140.154 uV 17:16:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.611 uVs 17:16:54 Integrated Voltage Measurement... 17:17:03 Voltage Offset Correction: v_off_ini = 142.985 uV, v_off_fin = 135.816 uV 17:17:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.811 uVs 17:17:06 I2Y Average and RMS of Measurements VT = -360.593 +- 0.984 uVs I2Y = -33.175 +- 0.090 uTm^2 17:17:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:24 Integrated Voltage Measurement... 17:17:33 Voltage Offset Correction: v_off_ini = 150.341 uV, v_off_fin = 150.644 uV 17:17:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.645 uVs 17:17:33 Integrated Voltage Measurement... 17:17:42 Voltage Offset Correction: v_off_ini = 152.594 uV, v_off_fin = 158.731 uV 17:17:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.540 uVs 17:17:42 Integrated Voltage Measurement... 17:17:51 Voltage Offset Correction: v_off_ini = 139.442 uV, v_off_fin = 146.143 uV 17:17:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.377 uVs 17:17:51 Integrated Voltage Measurement... 17:18:00 Voltage Offset Correction: v_off_ini = 149.009 uV, v_off_fin = 151.620 uV 17:18:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.363 uVs 17:18:00 Integrated Voltage Measurement... 17:18:09 Voltage Offset Correction: v_off_ini = 131.402 uV, v_off_fin = 142.435 uV 17:18:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.464 uVs 17:18:09 Integrated Voltage Measurement... 17:18:18 Voltage Offset Correction: v_off_ini = 151.524 uV, v_off_fin = 160.266 uV 17:18:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.182 uVs 17:18:22 I1X Average and RMS of Measurements VT = -73.595 +- 4.611 uVs I1X = 14.720 +- 0.922 uTm 17:18:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:29 Integrated Voltage Measurement... 17:18:38 Voltage Offset Correction: v_off_ini = 133.396 uV, v_off_fin = 136.711 uV 17:18:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.370 uVs 17:18:38 Integrated Voltage Measurement... 17:18:47 Voltage Offset Correction: v_off_ini = 154.253 uV, v_off_fin = 160.283 uV 17:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 203.045 uVs 17:18:47 Integrated Voltage Measurement... 17:18:56 Voltage Offset Correction: v_off_ini = 147.853 uV, v_off_fin = 155.454 uV 17:18:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.130 uVs 17:18:56 Integrated Voltage Measurement... 17:19:05 Voltage Offset Correction: v_off_ini = 147.706 uV, v_off_fin = 162.582 uV 17:19:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 181.617 uVs 17:19:05 Integrated Voltage Measurement... 17:19:14 Voltage Offset Correction: v_off_ini = 161.005 uV, v_off_fin = 137.148 uV 17:19:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -196.681 uVs 17:19:14 Integrated Voltage Measurement... 17:19:23 Voltage Offset Correction: v_off_ini = 145.735 uV, v_off_fin = 169.793 uV 17:19:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.383 uVs 17:19:27 I1Y Average and RMS of Measurements VT = -193.371 +- 3.431 uVs I1Y = -38.668 +- 0.685 uTm 17:19:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:35 Integrated Voltage Measurement... 17:19:44 Voltage Offset Correction: v_off_ini = 152.837 uV, v_off_fin = 147.443 uV 17:19:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.195 uVs 17:19:44 Integrated Voltage Measurement... 17:19:53 Voltage Offset Correction: v_off_ini = 155.808 uV, v_off_fin = 169.484 uV 17:19:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.899 uVs 17:19:53 Integrated Voltage Measurement... 17:20:02 Voltage Offset Correction: v_off_ini = 160.849 uV, v_off_fin = 141.799 uV 17:20:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.079 uVs 17:20:02 Integrated Voltage Measurement... 17:20:11 Voltage Offset Correction: v_off_ini = 148.794 uV, v_off_fin = 167.903 uV 17:20:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.939 uVs 17:20:11 Integrated Voltage Measurement... 17:20:20 Voltage Offset Correction: v_off_ini = 163.540 uV, v_off_fin = 169.097 uV 17:20:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.460 uVs 17:20:20 Integrated Voltage Measurement... 17:20:29 Voltage Offset Correction: v_off_ini = 178.704 uV, v_off_fin = 179.522 uV 17:20:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.520 uVs 17:20:31 I2X Average and RMS of Measurements VT = -84.349 +- 4.123 uVs I2X = 7.760 +- 0.379 uTm^2 17:20:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:39 Integrated Voltage Measurement... 17:20:48 Voltage Offset Correction: v_off_ini = 167.034 uV, v_off_fin = 169.800 uV 17:20:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.911 uVs 17:20:48 Integrated Voltage Measurement... 17:20:57 Voltage Offset Correction: v_off_ini = 163.975 uV, v_off_fin = 159.702 uV 17:20:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.555 uVs 17:20:57 Integrated Voltage Measurement... 17:21:06 Voltage Offset Correction: v_off_ini = 150.754 uV, v_off_fin = 151.810 uV 17:21:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.650 uVs 17:21:06 Integrated Voltage Measurement... 17:21:15 Voltage Offset Correction: v_off_ini = 144.971 uV, v_off_fin = 149.095 uV 17:21:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.333 uVs 17:21:15 Integrated Voltage Measurement... 17:21:24 Voltage Offset Correction: v_off_ini = 155.699 uV, v_off_fin = 151.907 uV 17:21:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.673 uVs 17:21:24 Integrated Voltage Measurement... 17:21:33 Voltage Offset Correction: v_off_ini = 171.880 uV, v_off_fin = 160.118 uV 17:21:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.675 uVs 17:21:35 I2Y Average and RMS of Measurements VT = -341.966 +- 3.193 uVs I2Y = -31.461 +- 0.294 uTm^2 17:21:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:54 Integrated Voltage Measurement... 17:22:03 Voltage Offset Correction: v_off_ini = 155.110 uV, v_off_fin = 143.031 uV 17:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.499 uVs 17:22:03 Integrated Voltage Measurement... 17:22:12 Voltage Offset Correction: v_off_ini = 151.638 uV, v_off_fin = 152.539 uV 17:22:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.880 uVs 17:22:12 Integrated Voltage Measurement... 17:22:21 Voltage Offset Correction: v_off_ini = 157.209 uV, v_off_fin = 159.474 uV 17:22:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.615 uVs 17:22:21 Integrated Voltage Measurement... 17:22:30 Voltage Offset Correction: v_off_ini = 164.623 uV, v_off_fin = 167.716 uV 17:22:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.611 uVs 17:22:30 Integrated Voltage Measurement... 17:22:39 Voltage Offset Correction: v_off_ini = 168.307 uV, v_off_fin = 158.311 uV 17:22:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.313 uVs 17:22:39 Integrated Voltage Measurement... 17:22:48 Voltage Offset Correction: v_off_ini = 159.315 uV, v_off_fin = 145.515 uV 17:22:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.911 uVs 17:22:52 I1X Average and RMS of Measurements VT = -79.471 +- 7.880 uVs I1X = 15.894 +- 1.576 uTm 17:22:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:59 Integrated Voltage Measurement... 17:23:08 Voltage Offset Correction: v_off_ini = 156.331 uV, v_off_fin = 141.985 uV 17:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.166 uVs 17:23:08 Integrated Voltage Measurement... 17:23:17 Voltage Offset Correction: v_off_ini = 141.956 uV, v_off_fin = 164.381 uV 17:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 214.174 uVs 17:23:17 Integrated Voltage Measurement... 17:23:26 Voltage Offset Correction: v_off_ini = 149.368 uV, v_off_fin = 134.431 uV 17:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -210.575 uVs 17:23:26 Integrated Voltage Measurement... 17:23:35 Voltage Offset Correction: v_off_ini = 153.108 uV, v_off_fin = 160.785 uV 17:23:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 201.414 uVs 17:23:35 Integrated Voltage Measurement... 17:23:44 Voltage Offset Correction: v_off_ini = 148.198 uV, v_off_fin = 130.618 uV 17:23:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -183.451 uVs 17:23:44 Integrated Voltage Measurement... 17:23:53 Voltage Offset Correction: v_off_ini = 159.243 uV, v_off_fin = 169.783 uV 17:23:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 192.468 uVs 17:23:57 I1Y Average and RMS of Measurements VT = -196.708 +- 7.373 uVs I1Y = -39.335 +- 1.474 uTm 17:24:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:05 Integrated Voltage Measurement... 17:24:13 Voltage Offset Correction: v_off_ini = 154.027 uV, v_off_fin = 153.646 uV 17:24:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.282 uVs 17:24:14 Integrated Voltage Measurement... 17:24:23 Voltage Offset Correction: v_off_ini = 174.621 uV, v_off_fin = 164.492 uV 17:24:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.509 uVs 17:24:23 Integrated Voltage Measurement... 17:24:32 Voltage Offset Correction: v_off_ini = 154.129 uV, v_off_fin = 146.689 uV 17:24:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.126 uVs 17:24:32 Integrated Voltage Measurement... 17:24:41 Voltage Offset Correction: v_off_ini = 174.000 uV, v_off_fin = 176.669 uV 17:24:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.235 uVs 17:24:41 Integrated Voltage Measurement... 17:24:50 Voltage Offset Correction: v_off_ini = 169.852 uV, v_off_fin = 153.145 uV 17:24:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.839 uVs 17:24:50 Integrated Voltage Measurement... 17:24:59 Voltage Offset Correction: v_off_ini = 165.170 uV, v_off_fin = 175.920 uV 17:24:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.901 uVs 17:25:01 I2X Average and RMS of Measurements VT = -75.815 +- 5.432 uVs I2X = 6.975 +- 0.500 uTm^2 17:25:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:09 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = 172.446 uV, v_off_fin = 180.471 uV 17:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.709 uVs 17:25:18 Integrated Voltage Measurement... 17:25:27 Voltage Offset Correction: v_off_ini = 194.201 uV, v_off_fin = 192.044 uV 17:25:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.628 uVs 17:25:27 Integrated Voltage Measurement... 17:25:36 Voltage Offset Correction: v_off_ini = 193.615 uV, v_off_fin = 192.886 uV 17:25:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.312 uVs 17:25:36 Integrated Voltage Measurement... 17:25:45 Voltage Offset Correction: v_off_ini = 193.563 uV, v_off_fin = 185.582 uV 17:25:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.758 uVs 17:25:45 Integrated Voltage Measurement... 17:25:54 Voltage Offset Correction: v_off_ini = 177.131 uV, v_off_fin = 188.376 uV 17:25:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.450 uVs 17:25:54 Integrated Voltage Measurement... 17:26:03 Voltage Offset Correction: v_off_ini = 196.907 uV, v_off_fin = 182.983 uV 17:26:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.872 uVs 17:26:05 I2Y Average and RMS of Measurements VT = -324.621 +- 4.310 uVs I2Y = -29.865 +- 0.396 uTm^2 17:26:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:24 Integrated Voltage Measurement... 17:26:33 Voltage Offset Correction: v_off_ini = 184.195 uV, v_off_fin = 167.018 uV 17:26:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.999 uVs 17:26:33 Integrated Voltage Measurement... 17:26:42 Voltage Offset Correction: v_off_ini = 189.188 uV, v_off_fin = 190.185 uV 17:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 69.297 uVs 17:26:42 Integrated Voltage Measurement... 17:26:51 Voltage Offset Correction: v_off_ini = 191.087 uV, v_off_fin = 186.508 uV 17:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.880 uVs 17:26:51 Integrated Voltage Measurement... 17:27:00 Voltage Offset Correction: v_off_ini = 189.439 uV, v_off_fin = 194.251 uV 17:27:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.292 uVs 17:27:00 Integrated Voltage Measurement... 17:27:09 Voltage Offset Correction: v_off_ini = 207.792 uV, v_off_fin = 187.401 uV 17:27:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.973 uVs 17:27:09 Integrated Voltage Measurement... 17:27:18 Voltage Offset Correction: v_off_ini = 194.256 uV, v_off_fin = 194.855 uV 17:27:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.763 uVs 17:27:22 I1X Average and RMS of Measurements VT = -89.034 +- 0.825 uVs I1X = 17.807 +- 0.165 uTm 17:27:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:29 Integrated Voltage Measurement... 17:27:37 Voltage Offset Correction: v_off_ini = 223.752 uV, v_off_fin = 211.393 uV 17:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -202.360 uVs 17:27:38 Integrated Voltage Measurement... 17:27:46 Voltage Offset Correction: v_off_ini = 198.254 uV, v_off_fin = 201.953 uV 17:27:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.393 uVs 17:27:47 Integrated Voltage Measurement... 17:27:55 Voltage Offset Correction: v_off_ini = 196.043 uV, v_off_fin = 186.810 uV 17:27:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.160 uVs 17:27:56 Integrated Voltage Measurement... 17:28:04 Voltage Offset Correction: v_off_ini = 186.609 uV, v_off_fin = 197.526 uV 17:28:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.911 uVs 17:28:05 Integrated Voltage Measurement... 17:28:13 Voltage Offset Correction: v_off_ini = 194.709 uV, v_off_fin = 181.019 uV 17:28:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.987 uVs 17:28:13 Integrated Voltage Measurement... 17:28:22 Voltage Offset Correction: v_off_ini = 200.987 uV, v_off_fin = 211.336 uV 17:28:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.236 uVs 17:28:27 I1Y Average and RMS of Measurements VT = -204.841 +- 2.876 uVs I1Y = -40.966 +- 0.574 uTm 17:28:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:34 Integrated Voltage Measurement... 17:28:43 Voltage Offset Correction: v_off_ini = 182.422 uV, v_off_fin = 176.987 uV 17:28:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -73.344 uVs 17:28:43 Integrated Voltage Measurement... 17:28:52 Voltage Offset Correction: v_off_ini = 199.326 uV, v_off_fin = 215.468 uV 17:28:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.207 uVs 17:28:52 Integrated Voltage Measurement... 17:29:01 Voltage Offset Correction: v_off_ini = 193.907 uV, v_off_fin = 202.857 uV 17:29:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.773 uVs 17:29:01 Integrated Voltage Measurement... 17:29:10 Voltage Offset Correction: v_off_ini = 207.374 uV, v_off_fin = 204.755 uV 17:29:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.740 uVs 17:29:10 Integrated Voltage Measurement... 17:29:19 Voltage Offset Correction: v_off_ini = 212.153 uV, v_off_fin = 201.197 uV 17:29:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -64.900 uVs 17:29:19 Integrated Voltage Measurement... 17:29:28 Voltage Offset Correction: v_off_ini = 213.137 uV, v_off_fin = 213.433 uV 17:29:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.969 uVs 17:29:31 I2X Average and RMS of Measurements VT = -78.822 +- 10.420 uVs I2X = 7.252 +- 0.959 uTm^2 17:29:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:39 Integrated Voltage Measurement... 17:29:48 Voltage Offset Correction: v_off_ini = 188.445 uV, v_off_fin = 197.601 uV 17:29:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.952 uVs 17:29:48 Integrated Voltage Measurement... 17:29:57 Voltage Offset Correction: v_off_ini = 200.870 uV, v_off_fin = 192.659 uV 17:29:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.542 uVs 17:29:57 Integrated Voltage Measurement... 17:30:06 Voltage Offset Correction: v_off_ini = 181.381 uV, v_off_fin = 198.608 uV 17:30:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.084 uVs 17:30:06 Integrated Voltage Measurement... 17:30:15 Voltage Offset Correction: v_off_ini = 205.895 uV, v_off_fin = 202.729 uV 17:30:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.974 uVs 17:30:15 Integrated Voltage Measurement... 17:30:24 Voltage Offset Correction: v_off_ini = 212.568 uV, v_off_fin = 208.670 uV 17:30:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.473 uVs 17:30:24 Integrated Voltage Measurement... 17:30:33 Voltage Offset Correction: v_off_ini = 214.336 uV, v_off_fin = 226.397 uV 17:30:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.420 uVs 17:30:35 I2Y Average and RMS of Measurements VT = -318.241 +- 1.966 uVs I2Y = -29.278 +- 0.181 uTm^2 17:30:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:53 Integrated Voltage Measurement... 17:31:02 Voltage Offset Correction: v_off_ini = 236.477 uV, v_off_fin = 226.973 uV 17:31:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.724 uVs 17:31:02 Integrated Voltage Measurement... 17:31:11 Voltage Offset Correction: v_off_ini = 229.758 uV, v_off_fin = 234.605 uV 17:31:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.530 uVs 17:31:11 Integrated Voltage Measurement... 17:31:20 Voltage Offset Correction: v_off_ini = 216.549 uV, v_off_fin = 214.746 uV 17:31:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.031 uVs 17:31:20 Integrated Voltage Measurement... 17:31:29 Voltage Offset Correction: v_off_ini = 206.610 uV, v_off_fin = 215.247 uV 17:31:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.290 uVs 17:31:29 Integrated Voltage Measurement... 17:31:38 Voltage Offset Correction: v_off_ini = 220.415 uV, v_off_fin = 209.895 uV 17:31:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.916 uVs 17:31:38 Integrated Voltage Measurement... 17:31:47 Voltage Offset Correction: v_off_ini = 222.906 uV, v_off_fin = 224.576 uV 17:31:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.043 uVs 17:31:52 I1X Average and RMS of Measurements VT = -83.256 +- 11.924 uVs I1X = 16.651 +- 2.385 uTm 17:31:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:31:58 Integrated Voltage Measurement... 17:32:07 Voltage Offset Correction: v_off_ini = 218.092 uV, v_off_fin = 215.895 uV 17:32:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.022 uVs 17:32:07 Integrated Voltage Measurement... 17:32:16 Voltage Offset Correction: v_off_ini = 234.234 uV, v_off_fin = 251.562 uV 17:32:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 202.588 uVs 17:32:16 Integrated Voltage Measurement... 17:32:25 Voltage Offset Correction: v_off_ini = 215.953 uV, v_off_fin = 209.860 uV 17:32:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -199.779 uVs 17:32:25 Integrated Voltage Measurement... 17:32:34 Voltage Offset Correction: v_off_ini = 223.257 uV, v_off_fin = 230.999 uV 17:32:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.436 uVs 17:32:34 Integrated Voltage Measurement... 17:32:43 Voltage Offset Correction: v_off_ini = 233.170 uV, v_off_fin = 220.608 uV 17:32:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.493 uVs 17:32:43 Integrated Voltage Measurement... 17:32:52 Voltage Offset Correction: v_off_ini = 226.657 uV, v_off_fin = 237.793 uV 17:32:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.822 uVs 17:32:56 I1Y Average and RMS of Measurements VT = -204.023 +- 3.333 uVs I1Y = -40.800 +- 0.668 uTm 17:33:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:04 Integrated Voltage Measurement... 17:33:13 Voltage Offset Correction: v_off_ini = 231.913 uV, v_off_fin = 223.742 uV 17:33:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.548 uVs 17:33:13 Integrated Voltage Measurement... 17:33:22 Voltage Offset Correction: v_off_ini = 227.029 uV, v_off_fin = 241.383 uV 17:33:22 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 87.364 uVs 17:33:22 Integrated Voltage Measurement... 17:33:31 Voltage Offset Correction: v_off_ini = 231.377 uV, v_off_fin = 216.536 uV 17:33:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.222 uVs 17:33:31 Integrated Voltage Measurement... 17:33:40 Voltage Offset Correction: v_off_ini = 225.865 uV, v_off_fin = 228.107 uV 17:33:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 62.338 uVs 17:33:40 Integrated Voltage Measurement... 17:33:49 Voltage Offset Correction: v_off_ini = 227.792 uV, v_off_fin = 205.904 uV 17:33:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.816 uVs 17:33:49 Integrated Voltage Measurement... 17:33:58 Voltage Offset Correction: v_off_ini = 212.170 uV, v_off_fin = 225.585 uV 17:33:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.893 uVs 17:34:00 I2X Average and RMS of Measurements VT = -77.697 +- 5.771 uVs I2X = 7.149 +- 0.531 uTm^2 17:34:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:08 Integrated Voltage Measurement... 17:34:17 Voltage Offset Correction: v_off_ini = 218.097 uV, v_off_fin = 218.664 uV 17:34:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.418 uVs 17:34:17 Integrated Voltage Measurement... 17:34:26 Voltage Offset Correction: v_off_ini = 227.698 uV, v_off_fin = 229.237 uV 17:34:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.903 uVs 17:34:26 Integrated Voltage Measurement... 17:34:35 Voltage Offset Correction: v_off_ini = 228.932 uV, v_off_fin = 230.767 uV 17:34:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.943 uVs 17:34:35 Integrated Voltage Measurement... 17:34:44 Voltage Offset Correction: v_off_ini = 226.049 uV, v_off_fin = 225.823 uV 17:34:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.000 uVs 17:34:44 Integrated Voltage Measurement... 17:34:53 Voltage Offset Correction: v_off_ini = 233.928 uV, v_off_fin = 234.994 uV 17:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.643 uVs 17:34:53 Integrated Voltage Measurement... 17:35:02 Voltage Offset Correction: v_off_ini = 223.311 uV, v_off_fin = 228.589 uV 17:35:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.126 uVs 17:35:04 I2Y Average and RMS of Measurements VT = -301.172 +- 4.008 uVs I2Y = -27.708 +- 0.369 uTm^2 17:35:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:23 Integrated Voltage Measurement... 17:35:32 Voltage Offset Correction: v_off_ini = 241.411 uV, v_off_fin = 247.034 uV 17:35:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -72.415 uVs 17:35:32 Integrated Voltage Measurement... 17:35:41 Voltage Offset Correction: v_off_ini = 263.295 uV, v_off_fin = 251.650 uV 17:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 62.513 uVs 17:35:41 Integrated Voltage Measurement... 17:35:50 Voltage Offset Correction: v_off_ini = 247.728 uV, v_off_fin = 243.673 uV 17:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.904 uVs 17:35:50 Integrated Voltage Measurement... 17:35:59 Voltage Offset Correction: v_off_ini = 248.049 uV, v_off_fin = 239.676 uV 17:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.155 uVs 17:35:59 Integrated Voltage Measurement... 17:36:08 Voltage Offset Correction: v_off_ini = 240.758 uV, v_off_fin = 238.427 uV 17:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.572 uVs 17:36:08 Integrated Voltage Measurement... 17:36:17 Voltage Offset Correction: v_off_ini = 239.070 uV, v_off_fin = 241.780 uV 17:36:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.532 uVs 17:36:21 I1X Average and RMS of Measurements VT = -82.015 +- 11.875 uVs I1X = 16.404 +- 2.374 uTm 17:36:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:36:28 Integrated Voltage Measurement... 17:36:37 Voltage Offset Correction: v_off_ini = 240.173 uV, v_off_fin = 236.763 uV 17:36:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.876 uVs 17:36:37 Integrated Voltage Measurement... 17:36:46 Voltage Offset Correction: v_off_ini = 250.643 uV, v_off_fin = 258.712 uV 17:36:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.467 uVs 17:36:46 Integrated Voltage Measurement... 17:36:55 Voltage Offset Correction: v_off_ini = 254.549 uV, v_off_fin = 243.132 uV 17:36:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.849 uVs 17:36:55 Integrated Voltage Measurement... 17:37:03 Voltage Offset Correction: v_off_ini = 247.279 uV, v_off_fin = 259.663 uV 17:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.551 uVs 17:37:04 Integrated Voltage Measurement... 17:37:12 Voltage Offset Correction: v_off_ini = 234.997 uV, v_off_fin = 225.921 uV 17:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.238 uVs 17:37:13 Integrated Voltage Measurement... 17:37:21 Voltage Offset Correction: v_off_ini = 233.089 uV, v_off_fin = 257.140 uV 17:37:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.146 uVs 17:37:26 I1Y Average and RMS of Measurements VT = -204.021 +- 0.617 uVs I1Y = -40.802 +- 0.125 uTm 17:37:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:37:33 Integrated Voltage Measurement... 17:37:42 Voltage Offset Correction: v_off_ini = 252.479 uV, v_off_fin = 245.742 uV 17:37:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -75.044 uVs 17:37:42 Integrated Voltage Measurement... 17:37:51 Voltage Offset Correction: v_off_ini = 250.286 uV, v_off_fin = 259.558 uV 17:37:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.300 uVs 17:37:51 Integrated Voltage Measurement... 17:38:00 Voltage Offset Correction: v_off_ini = 251.739 uV, v_off_fin = 244.815 uV 17:38:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.657 uVs 17:38:00 Integrated Voltage Measurement... 17:38:09 Voltage Offset Correction: v_off_ini = 256.932 uV, v_off_fin = 262.140 uV 17:38:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.568 uVs 17:38:09 Integrated Voltage Measurement... 17:38:18 Voltage Offset Correction: v_off_ini = 253.817 uV, v_off_fin = 248.789 uV 17:38:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.242 uVs 17:38:18 Integrated Voltage Measurement... 17:38:27 Voltage Offset Correction: v_off_ini = 256.616 uV, v_off_fin = 257.675 uV 17:38:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.511 uVs 17:38:30 I2X Average and RMS of Measurements VT = -80.554 +- 2.434 uVs I2X = 7.411 +- 0.224 uTm^2 17:38:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:37 Integrated Voltage Measurement... 17:38:46 Voltage Offset Correction: v_off_ini = 251.073 uV, v_off_fin = 249.635 uV 17:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.632 uVs 17:38:46 Integrated Voltage Measurement... 17:38:55 Voltage Offset Correction: v_off_ini = 244.658 uV, v_off_fin = 245.507 uV 17:38:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.513 uVs 17:38:55 Integrated Voltage Measurement... 17:39:04 Voltage Offset Correction: v_off_ini = 245.501 uV, v_off_fin = 226.448 uV 17:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.294 uVs 17:39:04 Integrated Voltage Measurement... 17:39:13 Voltage Offset Correction: v_off_ini = 225.892 uV, v_off_fin = 236.028 uV 17:39:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.930 uVs 17:39:13 Integrated Voltage Measurement... 17:39:22 Voltage Offset Correction: v_off_ini = 232.811 uV, v_off_fin = 248.661 uV 17:39:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.456 uVs 17:39:22 Integrated Voltage Measurement... 17:39:31 Voltage Offset Correction: v_off_ini = 248.892 uV, v_off_fin = 250.471 uV 17:39:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.486 uVs 17:39:34 I2Y Average and RMS of Measurements VT = -294.385 +- 1.803 uVs I2Y = -27.083 +- 0.166 uTm^2 17:39:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:52 Integrated Voltage Measurement... 17:40:01 Voltage Offset Correction: v_off_ini = 254.846 uV, v_off_fin = 258.860 uV 17:40:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -84.813 uVs 17:40:01 Integrated Voltage Measurement... 17:40:10 Voltage Offset Correction: v_off_ini = 255.225 uV, v_off_fin = 242.463 uV 17:40:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 81.762 uVs 17:40:10 Integrated Voltage Measurement... 17:40:19 Voltage Offset Correction: v_off_ini = 243.403 uV, v_off_fin = 231.533 uV 17:40:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.215 uVs 17:40:19 Integrated Voltage Measurement... 17:40:28 Voltage Offset Correction: v_off_ini = 247.679 uV, v_off_fin = 248.104 uV 17:40:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.228 uVs 17:40:28 Integrated Voltage Measurement... 17:40:37 Voltage Offset Correction: v_off_ini = 246.749 uV, v_off_fin = 246.624 uV 17:40:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.056 uVs 17:40:37 Integrated Voltage Measurement... 17:40:46 Voltage Offset Correction: v_off_ini = 251.229 uV, v_off_fin = 248.157 uV 17:40:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.155 uVs 17:40:50 I1X Average and RMS of Measurements VT = -91.371 +- 8.492 uVs I1X = 18.275 +- 1.698 uTm 17:40:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:57 Integrated Voltage Measurement... 17:41:06 Voltage Offset Correction: v_off_ini = 247.275 uV, v_off_fin = 240.095 uV 17:41:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.803 uVs 17:41:06 Integrated Voltage Measurement... 17:41:15 Voltage Offset Correction: v_off_ini = 238.668 uV, v_off_fin = 255.574 uV 17:41:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.231 uVs 17:41:15 Integrated Voltage Measurement... 17:41:24 Voltage Offset Correction: v_off_ini = 235.110 uV, v_off_fin = 230.980 uV 17:41:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.409 uVs 17:41:24 Integrated Voltage Measurement... 17:41:33 Voltage Offset Correction: v_off_ini = 247.892 uV, v_off_fin = 257.173 uV 17:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.238 uVs 17:41:33 Integrated Voltage Measurement... 17:41:42 Voltage Offset Correction: v_off_ini = 240.233 uV, v_off_fin = 231.741 uV 17:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.323 uVs 17:41:42 Integrated Voltage Measurement... 17:41:51 Voltage Offset Correction: v_off_ini = 254.181 uV, v_off_fin = 267.868 uV 17:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.634 uVs 17:41:55 I1Y Average and RMS of Measurements VT = -206.606 +- 1.931 uVs I1Y = -41.319 +- 0.388 uTm 17:42:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:03 Integrated Voltage Measurement... 17:42:12 Voltage Offset Correction: v_off_ini = 239.470 uV, v_off_fin = 250.766 uV 17:42:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -73.687 uVs 17:42:12 Integrated Voltage Measurement... 17:42:21 Voltage Offset Correction: v_off_ini = 263.818 uV, v_off_fin = 270.097 uV 17:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.872 uVs 17:42:21 Integrated Voltage Measurement... 17:42:30 Voltage Offset Correction: v_off_ini = 252.824 uV, v_off_fin = 241.213 uV 17:42:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.837 uVs 17:42:30 Integrated Voltage Measurement... 17:42:39 Voltage Offset Correction: v_off_ini = 247.859 uV, v_off_fin = 254.764 uV 17:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.353 uVs 17:42:39 Integrated Voltage Measurement... 17:42:48 Voltage Offset Correction: v_off_ini = 257.934 uV, v_off_fin = 236.849 uV 17:42:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.482 uVs 17:42:48 Integrated Voltage Measurement... 17:42:57 Voltage Offset Correction: v_off_ini = 253.717 uV, v_off_fin = 259.010 uV 17:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.762 uVs 17:42:59 I2X Average and RMS of Measurements VT = -76.499 +- 4.445 uVs I2X = 7.038 +- 0.409 uTm^2 17:43:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:07 Integrated Voltage Measurement... 17:43:16 Voltage Offset Correction: v_off_ini = 262.709 uV, v_off_fin = 246.529 uV 17:43:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.898 uVs 17:43:16 Integrated Voltage Measurement... 17:43:25 Voltage Offset Correction: v_off_ini = 250.606 uV, v_off_fin = 253.672 uV 17:43:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.717 uVs 17:43:25 Integrated Voltage Measurement... 17:43:34 Voltage Offset Correction: v_off_ini = 248.716 uV, v_off_fin = 256.866 uV 17:43:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.238 uVs 17:43:34 Integrated Voltage Measurement... 17:43:43 Voltage Offset Correction: v_off_ini = 261.758 uV, v_off_fin = 244.663 uV 17:43:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.908 uVs 17:43:43 Integrated Voltage Measurement... 17:43:52 Voltage Offset Correction: v_off_ini = 248.897 uV, v_off_fin = 251.313 uV 17:43:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.549 uVs 17:43:52 Integrated Voltage Measurement... 17:44:01 Voltage Offset Correction: v_off_ini = 244.455 uV, v_off_fin = 249.069 uV 17:44:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.898 uVs 17:44:03 I2Y Average and RMS of Measurements VT = -284.535 +- 3.316 uVs I2Y = -26.177 +- 0.305 uTm^2 17:44:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm