SLAC Magnetic Measurements Date: 10-28-2025 Time: 11:56:54 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16350 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 11:57:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:04 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:57:05 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:57:07 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:57:09 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:57:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:57:50 Integrated Voltage Measurement... 11:57:59 Voltage Offset Correction: v_off_ini = -39.961 uV, v_off_fin = -52.382 uV 11:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -135.609 uVs 11:57:59 Integrated Voltage Measurement... 11:58:08 Voltage Offset Correction: v_off_ini = -54.151 uV, v_off_fin = -40.425 uV 11:58:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.225 uVs 11:58:08 Integrated Voltage Measurement... 11:58:17 Voltage Offset Correction: v_off_ini = -61.286 uV, v_off_fin = -63.367 uV 11:58:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.137 uVs 11:58:17 Integrated Voltage Measurement... 11:58:26 Voltage Offset Correction: v_off_ini = -53.136 uV, v_off_fin = -43.673 uV 11:58:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.016 uVs 11:58:26 Integrated Voltage Measurement... 11:58:35 Voltage Offset Correction: v_off_ini = -49.021 uV, v_off_fin = -35.337 uV 11:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.745 uVs 11:58:35 Integrated Voltage Measurement... 11:58:44 Voltage Offset Correction: v_off_ini = -31.704 uV, v_off_fin = -31.068 uV 11:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.843 uVs 11:58:48 I1X Average and RMS of Measurements VT = -106.929 +- 3.948 uVs I1X = 21.386 +- 0.790 uTm 11:58:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:58:55 Integrated Voltage Measurement... 11:59:04 Voltage Offset Correction: v_off_ini = -33.760 uV, v_off_fin = -49.586 uV 11:59:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.077 uVs 11:59:04 Integrated Voltage Measurement... 11:59:13 Voltage Offset Correction: v_off_ini = -39.454 uV, v_off_fin = -21.593 uV 11:59:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.425 uVs 11:59:13 Integrated Voltage Measurement... 11:59:22 Voltage Offset Correction: v_off_ini = -46.694 uV, v_off_fin = -54.131 uV 11:59:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.605 uVs 11:59:22 Integrated Voltage Measurement... 11:59:31 Voltage Offset Correction: v_off_ini = -51.413 uV, v_off_fin = -37.966 uV 11:59:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.158 uVs 11:59:31 Integrated Voltage Measurement... 11:59:40 Voltage Offset Correction: v_off_ini = -41.789 uV, v_off_fin = -43.134 uV 11:59:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.077 uVs 11:59:40 Integrated Voltage Measurement... 11:59:49 Voltage Offset Correction: v_off_ini = -38.398 uV, v_off_fin = -26.519 uV 11:59:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.482 uVs 11:59:53 I1Y Average and RMS of Measurements VT = -223.471 +- 6.403 uVs I1Y = -44.694 +- 1.281 uTm 11:59:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:00:01 Integrated Voltage Measurement... 12:00:10 Voltage Offset Correction: v_off_ini = -26.965 uV, v_off_fin = -48.019 uV 12:00:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.539 uVs 12:00:10 Integrated Voltage Measurement... 12:00:19 Voltage Offset Correction: v_off_ini = -35.628 uV, v_off_fin = -24.506 uV 12:00:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.501 uVs 12:00:19 Integrated Voltage Measurement... 12:00:28 Voltage Offset Correction: v_off_ini = -54.620 uV, v_off_fin = -41.801 uV 12:00:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.199 uVs 12:00:28 Integrated Voltage Measurement... 12:00:37 Voltage Offset Correction: v_off_ini = -28.424 uV, v_off_fin = -17.755 uV 12:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.511 uVs 12:00:37 Integrated Voltage Measurement... 12:00:46 Voltage Offset Correction: v_off_ini = -31.002 uV, v_off_fin = -30.489 uV 12:00:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.394 uVs 12:00:46 Integrated Voltage Measurement... 12:00:55 Voltage Offset Correction: v_off_ini = -15.170 uV, v_off_fin = -9.606 uV 12:00:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.295 uVs 12:00:58 I2X Average and RMS of Measurements VT = -92.740 +- 9.977 uVs I2X = 8.532 +- 0.918 uTm^2 12:01:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:01:05 Integrated Voltage Measurement... 12:01:14 Voltage Offset Correction: v_off_ini = -22.200 uV, v_off_fin = -27.878 uV 12:01:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.160 uVs 12:01:14 Integrated Voltage Measurement... 12:01:23 Voltage Offset Correction: v_off_ini = -13.772 uV, v_off_fin = -20.084 uV 12:01:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.238 uVs 12:01:23 Integrated Voltage Measurement... 12:01:32 Voltage Offset Correction: v_off_ini = -31.098 uV, v_off_fin = -30.204 uV 12:01:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -480.994 uVs 12:01:32 Integrated Voltage Measurement... 12:01:41 Voltage Offset Correction: v_off_ini = -23.314 uV, v_off_fin = -32.722 uV 12:01:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.249 uVs 12:01:42 Integrated Voltage Measurement... 12:01:51 Voltage Offset Correction: v_off_ini = -25.379 uV, v_off_fin = -29.334 uV 12:01:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.747 uVs 12:01:51 Integrated Voltage Measurement... 12:02:00 Voltage Offset Correction: v_off_ini = -19.687 uV, v_off_fin = -26.890 uV 12:02:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.136 uVs 12:02:02 I2Y Average and RMS of Measurements VT = -480.254 +- 1.550 uVs I2Y = -44.183 +- 0.143 uTm^2 12:02:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:02:11 Integrated Voltage Measurement... 12:02:20 Voltage Offset Correction: v_off_ini = -17.507 uV, v_off_fin = -27.825 uV 12:02:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.072 uVs 12:02:20 Integrated Voltage Measurement... 12:02:29 Voltage Offset Correction: v_off_ini = -36.864 uV, v_off_fin = -30.740 uV 12:02:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.549 uVs 12:02:29 Integrated Voltage Measurement... 12:02:38 Voltage Offset Correction: v_off_ini = -24.932 uV, v_off_fin = -12.978 uV 12:02:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.461 uVs 12:02:38 Integrated Voltage Measurement... 12:02:47 Voltage Offset Correction: v_off_ini = -21.445 uV, v_off_fin = -33.134 uV 12:02:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.506 uVs 12:02:47 Integrated Voltage Measurement... 12:02:56 Voltage Offset Correction: v_off_ini = -38.514 uV, v_off_fin = -45.283 uV 12:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.301 uVs 12:02:56 Integrated Voltage Measurement... 12:03:05 Voltage Offset Correction: v_off_ini = -37.294 uV, v_off_fin = -52.941 uV 12:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.010 uVs 12:03:09 I1X Average and RMS of Measurements VT = -122.483 +- 5.038 uVs I1X = 24.497 +- 1.008 uTm 12:03:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:03:16 Integrated Voltage Measurement... 12:03:25 Voltage Offset Correction: v_off_ini = -50.240 uV, v_off_fin = -56.046 uV 12:03:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.183 uVs 12:03:25 Integrated Voltage Measurement... 12:03:34 Voltage Offset Correction: v_off_ini = -43.267 uV, v_off_fin = -33.257 uV 12:03:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.988 uVs 12:03:34 Integrated Voltage Measurement... 12:03:43 Voltage Offset Correction: v_off_ini = -42.217 uV, v_off_fin = -45.018 uV 12:03:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.828 uVs 12:03:43 Integrated Voltage Measurement... 12:03:53 Voltage Offset Correction: v_off_ini = -39.588 uV, v_off_fin = -34.293 uV 12:03:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.668 uVs 12:03:53 Integrated Voltage Measurement... 12:04:02 Voltage Offset Correction: v_off_ini = -41.669 uV, v_off_fin = -51.921 uV 12:04:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.183 uVs 12:04:02 Integrated Voltage Measurement... 12:04:11 Voltage Offset Correction: v_off_ini = -47.818 uV, v_off_fin = -33.147 uV 12:04:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.131 uVs 12:04:15 I1Y Average and RMS of Measurements VT = -223.830 +- 1.715 uVs I1Y = -44.766 +- 0.343 uTm 12:04:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:04:23 Integrated Voltage Measurement... 12:04:32 Voltage Offset Correction: v_off_ini = -46.002 uV, v_off_fin = -51.357 uV 12:04:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.618 uVs 12:04:32 Integrated Voltage Measurement... 12:04:41 Voltage Offset Correction: v_off_ini = -36.704 uV, v_off_fin = -28.358 uV 12:04:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.783 uVs 12:04:41 Integrated Voltage Measurement... 12:04:50 Voltage Offset Correction: v_off_ini = -26.742 uV, v_off_fin = -51.404 uV 12:04:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.640 uVs 12:04:50 Integrated Voltage Measurement... 12:04:59 Voltage Offset Correction: v_off_ini = -41.820 uV, v_off_fin = -47.808 uV 12:04:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.063 uVs 12:04:59 Integrated Voltage Measurement... 12:05:08 Voltage Offset Correction: v_off_ini = -52.734 uV, v_off_fin = -69.745 uV 12:05:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.070 uVs 12:05:08 Integrated Voltage Measurement... 12:05:17 Voltage Offset Correction: v_off_ini = -56.342 uV, v_off_fin = -40.267 uV 12:05:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.491 uVs 12:05:19 I2X Average and RMS of Measurements VT = -115.778 +- 9.816 uVs I2X = 10.652 +- 0.903 uTm^2 12:05:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:05:27 Integrated Voltage Measurement... 12:05:36 Voltage Offset Correction: v_off_ini = -48.750 uV, v_off_fin = -49.556 uV 12:05:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.698 uVs 12:05:36 Integrated Voltage Measurement... 12:05:45 Voltage Offset Correction: v_off_ini = -59.182 uV, v_off_fin = -53.134 uV 12:05:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.560 uVs 12:05:45 Integrated Voltage Measurement... 12:05:54 Voltage Offset Correction: v_off_ini = -48.378 uV, v_off_fin = -64.707 uV 12:05:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -468.099 uVs 12:05:54 Integrated Voltage Measurement... 12:06:03 Voltage Offset Correction: v_off_ini = -68.889 uV, v_off_fin = -68.064 uV 12:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.208 uVs 12:06:03 Integrated Voltage Measurement... 12:06:12 Voltage Offset Correction: v_off_ini = -65.292 uV, v_off_fin = -54.687 uV 12:06:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -471.950 uVs 12:06:12 Integrated Voltage Measurement... 12:06:21 Voltage Offset Correction: v_off_ini = -64.591 uV, v_off_fin = -61.752 uV 12:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.013 uVs 12:06:24 I2Y Average and RMS of Measurements VT = -469.421 +- 3.366 uVs I2Y = -43.187 +- 0.310 uTm^2 12:06:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:33 Integrated Voltage Measurement... 12:06:42 Voltage Offset Correction: v_off_ini = -61.974 uV, v_off_fin = -66.357 uV 12:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.180 uVs 12:06:42 Integrated Voltage Measurement... 12:06:51 Voltage Offset Correction: v_off_ini = -72.690 uV, v_off_fin = -61.499 uV 12:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.334 uVs 12:06:51 Integrated Voltage Measurement... 12:07:00 Voltage Offset Correction: v_off_ini = -67.120 uV, v_off_fin = -73.948 uV 12:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.007 uVs 12:07:00 Integrated Voltage Measurement... 12:07:09 Voltage Offset Correction: v_off_ini = -68.396 uV, v_off_fin = -67.573 uV 12:07:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.986 uVs 12:07:09 Integrated Voltage Measurement... 12:07:18 Voltage Offset Correction: v_off_ini = -58.927 uV, v_off_fin = -69.703 uV 12:07:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.377 uVs 12:07:18 Integrated Voltage Measurement... 12:07:27 Voltage Offset Correction: v_off_ini = -62.955 uV, v_off_fin = -58.163 uV 12:07:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.694 uVs 12:07:31 I1X Average and RMS of Measurements VT = -130.096 +- 5.786 uVs I1X = 26.019 +- 1.157 uTm 12:07:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:38 Integrated Voltage Measurement... 12:07:47 Voltage Offset Correction: v_off_ini = -62.969 uV, v_off_fin = -61.862 uV 12:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.400 uVs 12:07:47 Integrated Voltage Measurement... 12:07:56 Voltage Offset Correction: v_off_ini = -61.577 uV, v_off_fin = -48.953 uV 12:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.267 uVs 12:07:56 Integrated Voltage Measurement... 12:08:05 Voltage Offset Correction: v_off_ini = -66.193 uV, v_off_fin = -67.252 uV 12:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.186 uVs 12:08:05 Integrated Voltage Measurement... 12:08:14 Voltage Offset Correction: v_off_ini = -45.374 uV, v_off_fin = -35.538 uV 12:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.896 uVs 12:08:14 Integrated Voltage Measurement... 12:08:23 Voltage Offset Correction: v_off_ini = -59.406 uV, v_off_fin = -68.354 uV 12:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.939 uVs 12:08:23 Integrated Voltage Measurement... 12:08:32 Voltage Offset Correction: v_off_ini = -58.355 uV, v_off_fin = -54.314 uV 12:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.876 uVs 12:08:36 I1Y Average and RMS of Measurements VT = -211.761 +- 7.120 uVs I1Y = -42.352 +- 1.424 uTm 12:08:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:44 Integrated Voltage Measurement... 12:08:53 Voltage Offset Correction: v_off_ini = -53.676 uV, v_off_fin = -54.932 uV 12:08:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -131.024 uVs 12:08:53 Integrated Voltage Measurement... 12:09:02 Voltage Offset Correction: v_off_ini = -52.166 uV, v_off_fin = -36.814 uV 12:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.145 uVs 12:09:02 Integrated Voltage Measurement... 12:09:11 Voltage Offset Correction: v_off_ini = -35.800 uV, v_off_fin = -47.603 uV 12:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.178 uVs 12:09:11 Integrated Voltage Measurement... 12:09:20 Voltage Offset Correction: v_off_ini = -29.816 uV, v_off_fin = -31.701 uV 12:09:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 117.972 uVs 12:09:20 Integrated Voltage Measurement... 12:09:29 Voltage Offset Correction: v_off_ini = -42.088 uV, v_off_fin = -55.360 uV 12:09:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.946 uVs 12:09:29 Integrated Voltage Measurement... 12:09:38 Voltage Offset Correction: v_off_ini = -48.883 uV, v_off_fin = -34.324 uV 12:09:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.022 uVs 12:09:41 I2X Average and RMS of Measurements VT = -130.881 +- 5.274 uVs I2X = 12.041 +- 0.485 uTm^2 12:09:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:48 Integrated Voltage Measurement... 12:09:57 Voltage Offset Correction: v_off_ini = -38.832 uV, v_off_fin = -40.071 uV 12:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.475 uVs 12:09:57 Integrated Voltage Measurement... 12:10:06 Voltage Offset Correction: v_off_ini = -51.737 uV, v_off_fin = -37.965 uV 12:10:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 461.796 uVs 12:10:06 Integrated Voltage Measurement... 12:10:15 Voltage Offset Correction: v_off_ini = -40.385 uV, v_off_fin = -33.306 uV 12:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -470.308 uVs 12:10:15 Integrated Voltage Measurement... 12:10:24 Voltage Offset Correction: v_off_ini = -41.458 uV, v_off_fin = -50.061 uV 12:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.057 uVs 12:10:25 Integrated Voltage Measurement... 12:10:34 Voltage Offset Correction: v_off_ini = -49.084 uV, v_off_fin = -47.732 uV 12:10:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.564 uVs 12:10:34 Integrated Voltage Measurement... 12:10:43 Voltage Offset Correction: v_off_ini = -46.824 uV, v_off_fin = -55.060 uV 12:10:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.922 uVs 12:10:45 I2Y Average and RMS of Measurements VT = -457.187 +- 6.099 uVs I2Y = -42.062 +- 0.561 uTm^2 12:10:50 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:10:54 Integrated Voltage Measurement... 12:11:03 Voltage Offset Correction: v_off_ini = -52.747 uV, v_off_fin = -61.719 uV 12:11:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.931 uVs 12:11:03 Integrated Voltage Measurement... 12:11:12 Voltage Offset Correction: v_off_ini = -65.416 uV, v_off_fin = -63.828 uV 12:11:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.120 uVs 12:11:12 Integrated Voltage Measurement... 12:11:21 Voltage Offset Correction: v_off_ini = -71.779 uV, v_off_fin = -72.677 uV 12:11:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.643 uVs 12:11:21 Integrated Voltage Measurement... 12:11:30 Voltage Offset Correction: v_off_ini = -66.277 uV, v_off_fin = -67.431 uV 12:11:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.566 uVs 12:11:30 Integrated Voltage Measurement... 12:11:39 Voltage Offset Correction: v_off_ini = -59.096 uV, v_off_fin = -76.173 uV 12:11:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.281 uVs 12:11:39 Integrated Voltage Measurement... 12:11:48 Voltage Offset Correction: v_off_ini = -74.017 uV, v_off_fin = -72.918 uV 12:11:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.900 uVs 12:11:52 I1X Average and RMS of Measurements VT = -145.074 +- 2.891 uVs I1X = 29.015 +- 0.578 uTm 12:11:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:11:59 Integrated Voltage Measurement... 12:12:08 Voltage Offset Correction: v_off_ini = -82.790 uV, v_off_fin = -87.737 uV 12:12:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.831 uVs 12:12:08 Integrated Voltage Measurement... 12:12:17 Voltage Offset Correction: v_off_ini = -75.767 uV, v_off_fin = -72.113 uV 12:12:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.565 uVs 12:12:17 Integrated Voltage Measurement... 12:12:26 Voltage Offset Correction: v_off_ini = -94.145 uV, v_off_fin = -96.028 uV 12:12:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.264 uVs 12:12:26 Integrated Voltage Measurement... 12:12:35 Voltage Offset Correction: v_off_ini = -83.832 uV, v_off_fin = -71.294 uV 12:12:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.879 uVs 12:12:35 Integrated Voltage Measurement... 12:12:44 Voltage Offset Correction: v_off_ini = -88.409 uV, v_off_fin = -96.584 uV 12:12:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.439 uVs 12:12:44 Integrated Voltage Measurement... 12:12:53 Voltage Offset Correction: v_off_ini = -100.558 uV, v_off_fin = -82.552 uV 12:12:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.611 uVs 12:12:57 I1Y Average and RMS of Measurements VT = -209.265 +- 7.641 uVs I1Y = -41.853 +- 1.528 uTm 12:13:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:13:05 Integrated Voltage Measurement... 12:13:14 Voltage Offset Correction: v_off_ini = -88.136 uV, v_off_fin = -99.788 uV 12:13:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -154.715 uVs 12:13:14 Integrated Voltage Measurement... 12:13:23 Voltage Offset Correction: v_off_ini = -93.793 uV, v_off_fin = -94.667 uV 12:13:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.364 uVs 12:13:23 Integrated Voltage Measurement... 12:13:32 Voltage Offset Correction: v_off_ini = -97.563 uV, v_off_fin = -120.419 uV 12:13:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.053 uVs 12:13:32 Integrated Voltage Measurement... 12:13:41 Voltage Offset Correction: v_off_ini = -110.596 uV, v_off_fin = -95.552 uV 12:13:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.835 uVs 12:13:41 Integrated Voltage Measurement... 12:13:50 Voltage Offset Correction: v_off_ini = -108.723 uV, v_off_fin = -111.632 uV 12:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.931 uVs 12:13:50 Integrated Voltage Measurement... 12:13:59 Voltage Offset Correction: v_off_ini = -85.399 uV, v_off_fin = -91.222 uV 12:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.371 uVs 12:14:02 I2X Average and RMS of Measurements VT = -138.045 +- 6.533 uVs I2X = 12.700 +- 0.601 uTm^2 12:14:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:14:10 Integrated Voltage Measurement... 12:14:19 Voltage Offset Correction: v_off_ini = -112.319 uV, v_off_fin = -116.227 uV 12:14:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.548 uVs 12:14:19 Integrated Voltage Measurement... 12:14:28 Voltage Offset Correction: v_off_ini = -125.729 uV, v_off_fin = -117.662 uV 12:14:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 473.997 uVs 12:14:28 Integrated Voltage Measurement... 12:14:37 Voltage Offset Correction: v_off_ini = -119.244 uV, v_off_fin = -118.750 uV 12:14:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.909 uVs 12:14:37 Integrated Voltage Measurement... 12:14:46 Voltage Offset Correction: v_off_ini = -104.865 uV, v_off_fin = -110.186 uV 12:14:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 460.715 uVs 12:14:46 Integrated Voltage Measurement... 12:14:55 Voltage Offset Correction: v_off_ini = -107.824 uV, v_off_fin = -111.152 uV 12:14:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -455.733 uVs 12:14:55 Integrated Voltage Measurement... 12:15:04 Voltage Offset Correction: v_off_ini = -113.541 uV, v_off_fin = -115.457 uV 12:15:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 457.365 uVs 12:15:06 I2Y Average and RMS of Measurements VT = -456.711 +- 1.214 uVs I2Y = -42.017 +- 0.112 uTm^2 12:15:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:15:15 Integrated Voltage Measurement... 12:15:24 Voltage Offset Correction: v_off_ini = -115.659 uV, v_off_fin = -119.033 uV 12:15:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.497 uVs 12:15:24 Integrated Voltage Measurement... 12:15:33 Voltage Offset Correction: v_off_ini = -103.652 uV, v_off_fin = -97.493 uV 12:15:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.435 uVs 12:15:33 Integrated Voltage Measurement... 12:15:42 Voltage Offset Correction: v_off_ini = -130.157 uV, v_off_fin = -118.221 uV 12:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.052 uVs 12:15:42 Integrated Voltage Measurement... 12:15:51 Voltage Offset Correction: v_off_ini = -115.184 uV, v_off_fin = -99.567 uV 12:15:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.299 uVs 12:15:51 Integrated Voltage Measurement... 12:16:00 Voltage Offset Correction: v_off_ini = -111.103 uV, v_off_fin = -111.981 uV 12:16:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.062 uVs 12:16:00 Integrated Voltage Measurement... 12:16:09 Voltage Offset Correction: v_off_ini = -108.948 uV, v_off_fin = -112.651 uV 12:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.759 uVs 12:16:13 I1X Average and RMS of Measurements VT = -143.184 +- 1.815 uVs I1X = 28.637 +- 0.363 uTm 12:16:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:16:20 Integrated Voltage Measurement... 12:16:29 Voltage Offset Correction: v_off_ini = -115.328 uV, v_off_fin = -126.573 uV 12:16:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -197.494 uVs 12:16:29 Integrated Voltage Measurement... 12:16:38 Voltage Offset Correction: v_off_ini = -107.102 uV, v_off_fin = -106.374 uV 12:16:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.730 uVs 12:16:38 Integrated Voltage Measurement... 12:16:47 Voltage Offset Correction: v_off_ini = -100.876 uV, v_off_fin = -121.361 uV 12:16:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.002 uVs 12:16:47 Integrated Voltage Measurement... 12:16:56 Voltage Offset Correction: v_off_ini = -108.563 uV, v_off_fin = -104.714 uV 12:16:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.142 uVs 12:16:56 Integrated Voltage Measurement... 12:17:05 Voltage Offset Correction: v_off_ini = -122.547 uV, v_off_fin = -117.241 uV 12:17:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.249 uVs 12:17:05 Integrated Voltage Measurement... 12:17:14 Voltage Offset Correction: v_off_ini = -116.042 uV, v_off_fin = -111.328 uV 12:17:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.714 uVs 12:17:18 I1Y Average and RMS of Measurements VT = -200.222 +- 4.574 uVs I1Y = -40.045 +- 0.914 uTm 12:17:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:17:26 Integrated Voltage Measurement... 12:17:35 Voltage Offset Correction: v_off_ini = -129.579 uV, v_off_fin = -136.264 uV 12:17:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -152.332 uVs 12:17:35 Integrated Voltage Measurement... 12:17:44 Voltage Offset Correction: v_off_ini = -114.425 uV, v_off_fin = -113.995 uV 12:17:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.111 uVs 12:17:44 Integrated Voltage Measurement... 12:17:53 Voltage Offset Correction: v_off_ini = -119.608 uV, v_off_fin = -130.601 uV 12:17:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.882 uVs 12:17:53 Integrated Voltage Measurement... 12:18:02 Voltage Offset Correction: v_off_ini = -119.190 uV, v_off_fin = -110.539 uV 12:18:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.264 uVs 12:18:02 Integrated Voltage Measurement... 12:18:11 Voltage Offset Correction: v_off_ini = -115.077 uV, v_off_fin = -118.066 uV 12:18:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.398 uVs 12:18:11 Integrated Voltage Measurement... 12:18:20 Voltage Offset Correction: v_off_ini = -108.835 uV, v_off_fin = -98.174 uV 12:18:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.163 uVs 12:18:23 I2X Average and RMS of Measurements VT = -144.692 +- 4.009 uVs I2X = 13.311 +- 0.369 uTm^2 12:18:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:18:31 Integrated Voltage Measurement... 12:18:39 Voltage Offset Correction: v_off_ini = -102.839 uV, v_off_fin = -103.401 uV 12:18:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -434.388 uVs 12:18:40 Integrated Voltage Measurement... 12:18:49 Voltage Offset Correction: v_off_ini = -106.215 uV, v_off_fin = -109.126 uV 12:18:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.184 uVs 12:18:49 Integrated Voltage Measurement... 12:18:58 Voltage Offset Correction: v_off_ini = -103.608 uV, v_off_fin = -99.341 uV 12:18:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.921 uVs 12:18:58 Integrated Voltage Measurement... 12:19:07 Voltage Offset Correction: v_off_ini = -94.793 uV, v_off_fin = -94.574 uV 12:19:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.388 uVs 12:19:07 Integrated Voltage Measurement... 12:19:16 Voltage Offset Correction: v_off_ini = -86.689 uV, v_off_fin = -97.148 uV 12:19:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -441.866 uVs 12:19:16 Integrated Voltage Measurement... 12:19:25 Voltage Offset Correction: v_off_ini = -86.095 uV, v_off_fin = -102.095 uV 12:19:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.415 uVs 12:19:27 I2Y Average and RMS of Measurements VT = -444.694 +- 1.693 uVs I2Y = -40.912 +- 0.156 uTm^2 12:19:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:19:39 Integrated Voltage Measurement... 12:19:48 Voltage Offset Correction: v_off_ini = -95.615 uV, v_off_fin = -118.230 uV 12:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.880 uVs 12:19:48 Integrated Voltage Measurement... 12:19:57 Voltage Offset Correction: v_off_ini = -102.741 uV, v_off_fin = -110.044 uV 12:19:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.110 uVs 12:19:57 Integrated Voltage Measurement... 12:20:06 Voltage Offset Correction: v_off_ini = -104.372 uV, v_off_fin = -96.851 uV 12:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.399 uVs 12:20:06 Integrated Voltage Measurement... 12:20:15 Voltage Offset Correction: v_off_ini = -88.886 uV, v_off_fin = -87.345 uV 12:20:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.074 uVs 12:20:15 Integrated Voltage Measurement... 12:20:24 Voltage Offset Correction: v_off_ini = -97.705 uV, v_off_fin = -105.404 uV 12:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.832 uVs 12:20:24 Integrated Voltage Measurement... 12:20:33 Voltage Offset Correction: v_off_ini = -94.946 uV, v_off_fin = -81.889 uV 12:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.479 uVs 12:20:37 I1X Average and RMS of Measurements VT = -117.796 +- 4.384 uVs I1X = 23.559 +- 0.876 uTm 12:20:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:20:44 Integrated Voltage Measurement... 12:20:53 Voltage Offset Correction: v_off_ini = -94.652 uV, v_off_fin = -101.671 uV 12:20:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.043 uVs 12:20:53 Integrated Voltage Measurement... 12:21:02 Voltage Offset Correction: v_off_ini = -88.558 uV, v_off_fin = -91.058 uV 12:21:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.777 uVs 12:21:02 Integrated Voltage Measurement... 12:21:11 Voltage Offset Correction: v_off_ini = -89.167 uV, v_off_fin = -103.602 uV 12:21:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.670 uVs 12:21:11 Integrated Voltage Measurement... 12:21:20 Voltage Offset Correction: v_off_ini = -105.515 uV, v_off_fin = -94.950 uV 12:21:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.397 uVs 12:21:20 Integrated Voltage Measurement... 12:21:29 Voltage Offset Correction: v_off_ini = -94.494 uV, v_off_fin = -105.228 uV 12:21:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.224 uVs 12:21:29 Integrated Voltage Measurement... 12:21:38 Voltage Offset Correction: v_off_ini = -92.685 uV, v_off_fin = -85.060 uV 12:21:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.310 uVs 12:21:43 I1Y Average and RMS of Measurements VT = -196.070 +- 2.289 uVs I1Y = -39.214 +- 0.458 uTm 12:21:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:21:48 Integrated Voltage Measurement... 12:21:57 Voltage Offset Correction: v_off_ini = -103.074 uV, v_off_fin = -102.128 uV 12:21:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -114.407 uVs 12:21:57 Integrated Voltage Measurement... 12:22:06 Voltage Offset Correction: v_off_ini = -80.307 uV, v_off_fin = -83.068 uV 12:22:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.035 uVs 12:22:06 Integrated Voltage Measurement... 12:22:15 Voltage Offset Correction: v_off_ini = -99.178 uV, v_off_fin = -99.397 uV 12:22:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.228 uVs 12:22:15 Integrated Voltage Measurement... 12:22:24 Voltage Offset Correction: v_off_ini = -98.954 uV, v_off_fin = -101.126 uV 12:22:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.077 uVs 12:22:24 Integrated Voltage Measurement... 12:22:33 Voltage Offset Correction: v_off_ini = -96.318 uV, v_off_fin = -99.243 uV 12:22:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.058 uVs 12:22:33 Integrated Voltage Measurement... 12:22:42 Voltage Offset Correction: v_off_ini = -79.693 uV, v_off_fin = -81.561 uV 12:22:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.970 uVs 12:22:44 I2X Average and RMS of Measurements VT = -118.963 +- 5.838 uVs I2X = 10.945 +- 0.537 uTm^2 12:22:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:22:49 Integrated Voltage Measurement... 12:22:58 Voltage Offset Correction: v_off_ini = -82.945 uV, v_off_fin = -73.475 uV 12:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.641 uVs 12:22:58 Integrated Voltage Measurement... 12:23:07 Voltage Offset Correction: v_off_ini = -95.626 uV, v_off_fin = -87.858 uV 12:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.691 uVs 12:23:08 Integrated Voltage Measurement... 12:23:16 Voltage Offset Correction: v_off_ini = -90.403 uV, v_off_fin = -82.365 uV 12:23:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.314 uVs 12:23:17 Integrated Voltage Measurement... 12:23:26 Voltage Offset Correction: v_off_ini = -84.914 uV, v_off_fin = -93.270 uV 12:23:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 452.669 uVs 12:23:26 Integrated Voltage Measurement... 12:23:35 Voltage Offset Correction: v_off_ini = -89.245 uV, v_off_fin = -95.795 uV 12:23:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.831 uVs 12:23:35 Integrated Voltage Measurement... 12:23:44 Voltage Offset Correction: v_off_ini = -76.289 uV, v_off_fin = -79.597 uV 12:23:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.694 uVs 12:23:46 I2Y Average and RMS of Measurements VT = -450.473 +- 2.321 uVs I2Y = -41.444 +- 0.213 uTm^2 12:23:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:23:54 Integrated Voltage Measurement... 12:24:03 Voltage Offset Correction: v_off_ini = -72.501 uV, v_off_fin = -80.937 uV 12:24:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.341 uVs 12:24:03 Integrated Voltage Measurement... 12:24:12 Voltage Offset Correction: v_off_ini = -88.793 uV, v_off_fin = -88.395 uV 12:24:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.400 uVs 12:24:12 Integrated Voltage Measurement... 12:24:21 Voltage Offset Correction: v_off_ini = -90.442 uV, v_off_fin = -97.275 uV 12:24:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.916 uVs 12:24:21 Integrated Voltage Measurement... 12:24:30 Voltage Offset Correction: v_off_ini = -81.723 uV, v_off_fin = -86.004 uV 12:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.030 uVs 12:24:30 Integrated Voltage Measurement... 12:24:39 Voltage Offset Correction: v_off_ini = -82.212 uV, v_off_fin = -86.021 uV 12:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.503 uVs 12:24:39 Integrated Voltage Measurement... 12:24:48 Voltage Offset Correction: v_off_ini = -94.342 uV, v_off_fin = -94.690 uV 12:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.008 uVs 12:24:53 I1X Average and RMS of Measurements VT = -132.866 +- 1.064 uVs I1X = 26.573 +- 0.213 uTm 12:24:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:24:59 Integrated Voltage Measurement... 12:25:08 Voltage Offset Correction: v_off_ini = -95.323 uV, v_off_fin = -96.228 uV 12:25:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.232 uVs 12:25:09 Integrated Voltage Measurement... 12:25:17 Voltage Offset Correction: v_off_ini = -91.435 uV, v_off_fin = -75.271 uV 12:25:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.817 uVs 12:25:18 Integrated Voltage Measurement... 12:25:26 Voltage Offset Correction: v_off_ini = -84.522 uV, v_off_fin = -88.385 uV 12:25:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.458 uVs 12:25:27 Integrated Voltage Measurement... 12:25:35 Voltage Offset Correction: v_off_ini = -78.678 uV, v_off_fin = -81.992 uV 12:25:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.787 uVs 12:25:36 Integrated Voltage Measurement... 12:25:44 Voltage Offset Correction: v_off_ini = -94.179 uV, v_off_fin = -102.011 uV 12:25:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.743 uVs 12:25:45 Integrated Voltage Measurement... 12:25:53 Voltage Offset Correction: v_off_ini = -90.142 uV, v_off_fin = -82.057 uV 12:25:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.911 uVs 12:25:58 I1Y Average and RMS of Measurements VT = -204.325 +- 3.812 uVs I1Y = -40.865 +- 0.762 uTm 12:26:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:26:03 Integrated Voltage Measurement... 12:26:12 Voltage Offset Correction: v_off_ini = -82.611 uV, v_off_fin = -90.237 uV 12:26:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.741 uVs 12:26:12 Integrated Voltage Measurement... 12:26:21 Voltage Offset Correction: v_off_ini = -80.945 uV, v_off_fin = -83.781 uV 12:26:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.783 uVs 12:26:21 Integrated Voltage Measurement... 12:26:30 Voltage Offset Correction: v_off_ini = -103.850 uV, v_off_fin = -118.753 uV 12:26:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.800 uVs 12:26:30 Integrated Voltage Measurement... 12:26:39 Voltage Offset Correction: v_off_ini = -103.578 uV, v_off_fin = -87.358 uV 12:26:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.697 uVs 12:26:39 Integrated Voltage Measurement... 12:26:48 Voltage Offset Correction: v_off_ini = -95.921 uV, v_off_fin = -112.367 uV 12:26:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.471 uVs 12:26:48 Integrated Voltage Measurement... 12:26:57 Voltage Offset Correction: v_off_ini = -86.148 uV, v_off_fin = -93.456 uV 12:26:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.369 uVs 12:26:59 I2X Average and RMS of Measurements VT = -118.310 +- 1.525 uVs I2X = 10.885 +- 0.140 uTm^2 12:27:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:27:05 Integrated Voltage Measurement... 12:27:14 Voltage Offset Correction: v_off_ini = -103.033 uV, v_off_fin = -102.910 uV 12:27:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.412 uVs 12:27:14 Integrated Voltage Measurement... 12:27:23 Voltage Offset Correction: v_off_ini = -96.608 uV, v_off_fin = -111.734 uV 12:27:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 445.128 uVs 12:27:23 Integrated Voltage Measurement... 12:27:32 Voltage Offset Correction: v_off_ini = -96.329 uV, v_off_fin = -97.510 uV 12:27:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.766 uVs 12:27:32 Integrated Voltage Measurement... 12:27:41 Voltage Offset Correction: v_off_ini = -111.914 uV, v_off_fin = -120.912 uV 12:27:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 447.582 uVs 12:27:41 Integrated Voltage Measurement... 12:27:50 Voltage Offset Correction: v_off_ini = -117.693 uV, v_off_fin = -108.146 uV 12:27:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.848 uVs 12:27:50 Integrated Voltage Measurement... 12:27:59 Voltage Offset Correction: v_off_ini = -110.313 uV, v_off_fin = -106.284 uV 12:27:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.821 uVs 12:28:01 I2Y Average and RMS of Measurements VT = -452.593 +- 6.415 uVs I2Y = -41.639 +- 0.590 uTm^2 12:28:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:10 Integrated Voltage Measurement... 12:28:19 Voltage Offset Correction: v_off_ini = -116.142 uV, v_off_fin = -106.175 uV 12:28:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.007 uVs 12:28:19 Integrated Voltage Measurement... 12:28:28 Voltage Offset Correction: v_off_ini = -108.934 uV, v_off_fin = -105.185 uV 12:28:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.699 uVs 12:28:28 Integrated Voltage Measurement... 12:28:37 Voltage Offset Correction: v_off_ini = -108.101 uV, v_off_fin = -105.259 uV 12:28:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.813 uVs 12:28:37 Integrated Voltage Measurement... 12:28:46 Voltage Offset Correction: v_off_ini = -118.823 uV, v_off_fin = -94.935 uV 12:28:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.090 uVs 12:28:46 Integrated Voltage Measurement... 12:28:55 Voltage Offset Correction: v_off_ini = -99.207 uV, v_off_fin = -97.459 uV 12:28:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.133 uVs 12:28:55 Integrated Voltage Measurement... 12:29:04 Voltage Offset Correction: v_off_ini = -97.850 uV, v_off_fin = -101.955 uV 12:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.370 uVs 12:29:08 I1X Average and RMS of Measurements VT = -129.519 +- 5.494 uVs I1X = 25.904 +- 1.099 uTm 12:29:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:15 Integrated Voltage Measurement... 12:29:24 Voltage Offset Correction: v_off_ini = -83.926 uV, v_off_fin = -93.677 uV 12:29:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.486 uVs 12:29:24 Integrated Voltage Measurement... 12:29:33 Voltage Offset Correction: v_off_ini = -88.596 uV, v_off_fin = -73.242 uV 12:29:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.175 uVs 12:29:33 Integrated Voltage Measurement... 12:29:42 Voltage Offset Correction: v_off_ini = -93.988 uV, v_off_fin = -102.742 uV 12:29:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.721 uVs 12:29:42 Integrated Voltage Measurement... 12:29:51 Voltage Offset Correction: v_off_ini = -88.108 uV, v_off_fin = -75.328 uV 12:29:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.628 uVs 12:29:51 Integrated Voltage Measurement... 12:30:00 Voltage Offset Correction: v_off_ini = -100.349 uV, v_off_fin = -103.868 uV 12:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.447 uVs 12:30:00 Integrated Voltage Measurement... 12:30:09 Voltage Offset Correction: v_off_ini = -89.870 uV, v_off_fin = -86.711 uV 12:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.133 uVs 12:30:13 I1Y Average and RMS of Measurements VT = -203.765 +- 6.069 uVs I1Y = -40.753 +- 1.214 uTm 12:30:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:18 Integrated Voltage Measurement... 12:30:27 Voltage Offset Correction: v_off_ini = -80.107 uV, v_off_fin = -95.971 uV 12:30:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -147.339 uVs 12:30:27 Integrated Voltage Measurement... 12:30:36 Voltage Offset Correction: v_off_ini = -101.374 uV, v_off_fin = -90.202 uV 12:30:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.073 uVs 12:30:36 Integrated Voltage Measurement... 12:30:45 Voltage Offset Correction: v_off_ini = -84.128 uV, v_off_fin = -97.076 uV 12:30:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.187 uVs 12:30:45 Integrated Voltage Measurement... 12:30:54 Voltage Offset Correction: v_off_ini = -92.050 uV, v_off_fin = -90.756 uV 12:30:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.620 uVs 12:30:54 Integrated Voltage Measurement... 12:31:03 Voltage Offset Correction: v_off_ini = -79.759 uV, v_off_fin = -88.734 uV 12:31:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.408 uVs 12:31:03 Integrated Voltage Measurement... 12:31:12 Voltage Offset Correction: v_off_ini = -84.494 uV, v_off_fin = -83.150 uV 12:31:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.014 uVs 12:31:15 I2X Average and RMS of Measurements VT = -129.607 +- 3.390 uVs I2X = 11.924 +- 0.312 uTm^2 12:31:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:20 Integrated Voltage Measurement... 12:31:29 Voltage Offset Correction: v_off_ini = -69.355 uV, v_off_fin = -76.814 uV 12:31:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -454.123 uVs 12:31:29 Integrated Voltage Measurement... 12:31:38 Voltage Offset Correction: v_off_ini = -99.916 uV, v_off_fin = -75.561 uV 12:31:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.394 uVs 12:31:38 Integrated Voltage Measurement... 12:31:47 Voltage Offset Correction: v_off_ini = -61.692 uV, v_off_fin = -59.579 uV 12:31:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.628 uVs 12:31:47 Integrated Voltage Measurement... 12:31:56 Voltage Offset Correction: v_off_ini = -60.386 uV, v_off_fin = -55.437 uV 12:31:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.418 uVs 12:31:56 Integrated Voltage Measurement... 12:32:05 Voltage Offset Correction: v_off_ini = -60.637 uV, v_off_fin = -63.971 uV 12:32:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.704 uVs 12:32:05 Integrated Voltage Measurement... 12:32:14 Voltage Offset Correction: v_off_ini = -53.844 uV, v_off_fin = -51.999 uV 12:32:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 456.586 uVs 12:32:16 I2Y Average and RMS of Measurements VT = -459.809 +- 4.600 uVs I2Y = -42.303 +- 0.422 uTm^2 12:32:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:32:25 Integrated Voltage Measurement... 12:32:34 Voltage Offset Correction: v_off_ini = -56.599 uV, v_off_fin = -77.989 uV 12:32:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.124 uVs 12:32:34 Integrated Voltage Measurement... 12:32:43 Voltage Offset Correction: v_off_ini = -67.911 uV, v_off_fin = -70.495 uV 12:32:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.323 uVs 12:32:43 Integrated Voltage Measurement... 12:32:52 Voltage Offset Correction: v_off_ini = -66.096 uV, v_off_fin = -63.105 uV 12:32:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.438 uVs 12:32:52 Integrated Voltage Measurement... 12:33:01 Voltage Offset Correction: v_off_ini = -62.554 uV, v_off_fin = -66.882 uV 12:33:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.098 uVs 12:33:01 Integrated Voltage Measurement... 12:33:10 Voltage Offset Correction: v_off_ini = -73.855 uV, v_off_fin = -69.773 uV 12:33:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.502 uVs 12:33:10 Integrated Voltage Measurement... 12:33:19 Voltage Offset Correction: v_off_ini = -60.301 uV, v_off_fin = -59.314 uV 12:33:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.673 uVs 12:33:23 I1X Average and RMS of Measurements VT = -133.526 +- 4.469 uVs I1X = 26.706 +- 0.893 uTm 12:33:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:33:30 Integrated Voltage Measurement... 12:33:39 Voltage Offset Correction: v_off_ini = -81.710 uV, v_off_fin = -73.801 uV 12:33:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.329 uVs 12:33:39 Integrated Voltage Measurement... 12:33:48 Voltage Offset Correction: v_off_ini = -65.760 uV, v_off_fin = -52.191 uV 12:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.298 uVs 12:33:48 Integrated Voltage Measurement... 12:33:57 Voltage Offset Correction: v_off_ini = -53.740 uV, v_off_fin = -66.126 uV 12:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.377 uVs 12:33:57 Integrated Voltage Measurement... 12:34:06 Voltage Offset Correction: v_off_ini = -62.954 uV, v_off_fin = -58.320 uV 12:34:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.630 uVs 12:34:06 Integrated Voltage Measurement... 12:34:15 Voltage Offset Correction: v_off_ini = -67.630 uV, v_off_fin = -78.626 uV 12:34:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.578 uVs 12:34:15 Integrated Voltage Measurement... 12:34:24 Voltage Offset Correction: v_off_ini = -72.963 uV, v_off_fin = -71.255 uV 12:34:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.677 uVs 12:34:28 I1Y Average and RMS of Measurements VT = -213.315 +- 7.502 uVs I1Y = -42.660 +- 1.500 uTm 12:34:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:34:33 Integrated Voltage Measurement... 12:34:42 Voltage Offset Correction: v_off_ini = -66.543 uV, v_off_fin = -75.161 uV 12:34:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.656 uVs 12:34:42 Integrated Voltage Measurement... 12:34:51 Voltage Offset Correction: v_off_ini = -57.405 uV, v_off_fin = -56.734 uV 12:34:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.829 uVs 12:34:51 Integrated Voltage Measurement... 12:35:00 Voltage Offset Correction: v_off_ini = -58.714 uV, v_off_fin = -85.155 uV 12:35:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.774 uVs 12:35:00 Integrated Voltage Measurement... 12:35:09 Voltage Offset Correction: v_off_ini = -67.945 uV, v_off_fin = -72.680 uV 12:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.162 uVs 12:35:09 Integrated Voltage Measurement... 12:35:18 Voltage Offset Correction: v_off_ini = -82.791 uV, v_off_fin = -86.548 uV 12:35:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.569 uVs 12:35:18 Integrated Voltage Measurement... 12:35:27 Voltage Offset Correction: v_off_ini = -97.583 uV, v_off_fin = -76.563 uV 12:35:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.053 uVs 12:35:30 I2X Average and RMS of Measurements VT = -140.507 +- 2.338 uVs I2X = 12.927 +- 0.215 uTm^2 12:35:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:35:35 Integrated Voltage Measurement... 12:35:44 Voltage Offset Correction: v_off_ini = -85.888 uV, v_off_fin = -87.367 uV 12:35:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.285 uVs 12:35:44 Integrated Voltage Measurement... 12:35:53 Voltage Offset Correction: v_off_ini = -81.928 uV, v_off_fin = -79.373 uV 12:35:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 492.008 uVs 12:35:53 Integrated Voltage Measurement... 12:36:02 Voltage Offset Correction: v_off_ini = -75.748 uV, v_off_fin = -75.484 uV 12:36:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.952 uVs 12:36:02 Integrated Voltage Measurement... 12:36:11 Voltage Offset Correction: v_off_ini = -80.971 uV, v_off_fin = -68.447 uV 12:36:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.781 uVs 12:36:11 Integrated Voltage Measurement... 12:36:20 Voltage Offset Correction: v_off_ini = -68.178 uV, v_off_fin = -76.929 uV 12:36:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.621 uVs 12:36:20 Integrated Voltage Measurement... 12:36:29 Voltage Offset Correction: v_off_ini = -64.289 uV, v_off_fin = -72.662 uV 12:36:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.085 uVs 12:36:32 I2Y Average and RMS of Measurements VT = -469.122 +- 6.062 uVs I2Y = -43.159 +- 0.558 uTm^2 12:36:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:36:40 Integrated Voltage Measurement... 12:36:49 Voltage Offset Correction: v_off_ini = -59.869 uV, v_off_fin = -80.486 uV 12:36:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.476 uVs 12:36:49 Integrated Voltage Measurement... 12:36:58 Voltage Offset Correction: v_off_ini = -75.399 uV, v_off_fin = -65.120 uV 12:36:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.230 uVs 12:36:58 Integrated Voltage Measurement... 12:37:07 Voltage Offset Correction: v_off_ini = -76.784 uV, v_off_fin = -86.726 uV 12:37:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.085 uVs 12:37:07 Integrated Voltage Measurement... 12:37:16 Voltage Offset Correction: v_off_ini = -81.031 uV, v_off_fin = -78.814 uV 12:37:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.490 uVs 12:37:16 Integrated Voltage Measurement... 12:37:25 Voltage Offset Correction: v_off_ini = -73.622 uV, v_off_fin = -92.078 uV 12:37:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.725 uVs 12:37:25 Integrated Voltage Measurement... 12:37:34 Voltage Offset Correction: v_off_ini = -79.935 uV, v_off_fin = -84.023 uV 12:37:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 136.434 uVs 12:37:38 I1X Average and RMS of Measurements VT = -130.240 +- 11.040 uVs I1X = 26.050 +- 2.210 uTm 12:37:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:37:45 Integrated Voltage Measurement... 12:37:54 Voltage Offset Correction: v_off_ini = -88.429 uV, v_off_fin = -103.874 uV 12:37:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.309 uVs 12:37:54 Integrated Voltage Measurement... 12:38:03 Voltage Offset Correction: v_off_ini = -99.370 uV, v_off_fin = -82.519 uV 12:38:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.007 uVs 12:38:03 Integrated Voltage Measurement... 12:38:12 Voltage Offset Correction: v_off_ini = -90.404 uV, v_off_fin = -99.380 uV 12:38:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.198 uVs 12:38:12 Integrated Voltage Measurement... 12:38:21 Voltage Offset Correction: v_off_ini = -96.789 uV, v_off_fin = -73.393 uV 12:38:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.681 uVs 12:38:21 Integrated Voltage Measurement... 12:38:30 Voltage Offset Correction: v_off_ini = -94.542 uV, v_off_fin = -107.064 uV 12:38:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.567 uVs 12:38:30 Integrated Voltage Measurement... 12:38:39 Voltage Offset Correction: v_off_ini = -85.041 uV, v_off_fin = -72.648 uV 12:38:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.250 uVs 12:38:43 I1Y Average and RMS of Measurements VT = -220.835 +- 5.731 uVs I1Y = -44.164 +- 1.145 uTm 12:38:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:38:48 Integrated Voltage Measurement... 12:38:57 Voltage Offset Correction: v_off_ini = -101.576 uV, v_off_fin = -101.093 uV 12:38:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.096 uVs 12:38:57 Integrated Voltage Measurement... 12:39:06 Voltage Offset Correction: v_off_ini = -87.413 uV, v_off_fin = -87.941 uV 12:39:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.121 uVs 12:39:07 Integrated Voltage Measurement... 12:39:16 Voltage Offset Correction: v_off_ini = -95.896 uV, v_off_fin = -95.186 uV 12:39:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.006 uVs 12:39:16 Integrated Voltage Measurement... 12:39:25 Voltage Offset Correction: v_off_ini = -80.992 uV, v_off_fin = -78.341 uV 12:39:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.761 uVs 12:39:25 Integrated Voltage Measurement... 12:39:34 Voltage Offset Correction: v_off_ini = -90.414 uV, v_off_fin = -98.576 uV 12:39:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.148 uVs 12:39:34 Integrated Voltage Measurement... 12:39:43 Voltage Offset Correction: v_off_ini = -97.451 uV, v_off_fin = -76.680 uV 12:39:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.093 uVs 12:39:45 I2X Average and RMS of Measurements VT = -133.037 +- 7.152 uVs I2X = 12.239 +- 0.658 uTm^2 12:39:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:39:50 Integrated Voltage Measurement... 12:39:59 Voltage Offset Correction: v_off_ini = -83.148 uV, v_off_fin = -90.728 uV 12:39:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.537 uVs 12:39:59 Integrated Voltage Measurement... 12:40:08 Voltage Offset Correction: v_off_ini = -96.213 uV, v_off_fin = -94.994 uV 12:40:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.209 uVs 12:40:08 Integrated Voltage Measurement... 12:40:17 Voltage Offset Correction: v_off_ini = -100.102 uV, v_off_fin = -110.633 uV 12:40:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -482.398 uVs 12:40:17 Integrated Voltage Measurement... 12:40:26 Voltage Offset Correction: v_off_ini = -95.429 uV, v_off_fin = -94.789 uV 12:40:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 478.682 uVs 12:40:26 Integrated Voltage Measurement... 12:40:35 Voltage Offset Correction: v_off_ini = -109.975 uV, v_off_fin = -100.129 uV 12:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.383 uVs 12:40:35 Integrated Voltage Measurement... 12:40:44 Voltage Offset Correction: v_off_ini = -92.563 uV, v_off_fin = -92.034 uV 12:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.181 uVs 12:40:47 I2Y Average and RMS of Measurements VT = -470.565 +- 8.067 uVs I2Y = -43.292 +- 0.742 uTm^2 12:41:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:41:07 Integrated Voltage Measurement... 12:41:16 Voltage Offset Correction: v_off_ini = -109.762 uV, v_off_fin = -104.686 uV 12:41:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.849 uVs 12:41:16 Integrated Voltage Measurement... 12:41:25 Voltage Offset Correction: v_off_ini = -99.413 uV, v_off_fin = -90.501 uV 12:41:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.427 uVs 12:41:25 Integrated Voltage Measurement... 12:41:34 Voltage Offset Correction: v_off_ini = -108.643 uV, v_off_fin = -99.242 uV 12:41:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.212 uVs 12:41:34 Integrated Voltage Measurement... 12:41:43 Voltage Offset Correction: v_off_ini = -98.634 uV, v_off_fin = -88.951 uV 12:41:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.809 uVs 12:41:43 Integrated Voltage Measurement... 12:41:52 Voltage Offset Correction: v_off_ini = -89.062 uV, v_off_fin = -100.736 uV 12:41:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.748 uVs 12:41:52 Integrated Voltage Measurement... 12:42:01 Voltage Offset Correction: v_off_ini = -103.491 uV, v_off_fin = -87.449 uV 12:42:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.525 uVs 12:42:05 I1X Average and RMS of Measurements VT = -95.928 +- 7.621 uVs I1X = 19.186 +- 1.524 uTm 12:42:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:42:12 Integrated Voltage Measurement... 12:42:21 Voltage Offset Correction: v_off_ini = -100.839 uV, v_off_fin = -108.489 uV 12:42:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -222.275 uVs 12:42:21 Integrated Voltage Measurement... 12:42:30 Voltage Offset Correction: v_off_ini = -99.509 uV, v_off_fin = -89.763 uV 12:42:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.085 uVs 12:42:30 Integrated Voltage Measurement... 12:42:39 Voltage Offset Correction: v_off_ini = -99.132 uV, v_off_fin = -110.195 uV 12:42:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.850 uVs 12:42:39 Integrated Voltage Measurement... 12:42:48 Voltage Offset Correction: v_off_ini = -100.464 uV, v_off_fin = -91.790 uV 12:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.950 uVs 12:42:48 Integrated Voltage Measurement... 12:42:57 Voltage Offset Correction: v_off_ini = -101.994 uV, v_off_fin = -104.612 uV 12:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.893 uVs 12:42:57 Integrated Voltage Measurement... 12:43:06 Voltage Offset Correction: v_off_ini = -95.991 uV, v_off_fin = -77.560 uV 12:43:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.747 uVs 12:43:10 I1Y Average and RMS of Measurements VT = -216.800 +- 2.797 uVs I1Y = -43.361 +- 0.560 uTm 12:43:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:43:18 Integrated Voltage Measurement... 12:43:27 Voltage Offset Correction: v_off_ini = -89.020 uV, v_off_fin = -106.835 uV 12:43:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.800 uVs 12:43:27 Integrated Voltage Measurement... 12:43:36 Voltage Offset Correction: v_off_ini = -98.465 uV, v_off_fin = -94.748 uV 12:43:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.101 uVs 12:43:36 Integrated Voltage Measurement... 12:43:45 Voltage Offset Correction: v_off_ini = -92.390 uV, v_off_fin = -110.257 uV 12:43:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.426 uVs 12:43:45 Integrated Voltage Measurement... 12:43:54 Voltage Offset Correction: v_off_ini = -108.915 uV, v_off_fin = -109.758 uV 12:43:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.440 uVs 12:43:54 Integrated Voltage Measurement... 12:44:03 Voltage Offset Correction: v_off_ini = -113.695 uV, v_off_fin = -125.187 uV 12:44:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.216 uVs 12:44:03 Integrated Voltage Measurement... 12:44:12 Voltage Offset Correction: v_off_ini = -112.922 uV, v_off_fin = -99.578 uV 12:44:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.097 uVs 12:44:15 I2X Average and RMS of Measurements VT = -88.513 +- 10.762 uVs I2X = 8.144 +- 0.990 uTm^2 12:44:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:44:22 Integrated Voltage Measurement... 12:44:31 Voltage Offset Correction: v_off_ini = -109.694 uV, v_off_fin = -106.027 uV 12:44:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.058 uVs 12:44:31 Integrated Voltage Measurement... 12:44:40 Voltage Offset Correction: v_off_ini = -107.078 uV, v_off_fin = -112.212 uV 12:44:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 469.708 uVs 12:44:40 Integrated Voltage Measurement... 12:44:49 Voltage Offset Correction: v_off_ini = -102.824 uV, v_off_fin = -109.287 uV 12:44:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.122 uVs 12:44:50 Integrated Voltage Measurement... 12:44:59 Voltage Offset Correction: v_off_ini = -103.917 uV, v_off_fin = -109.746 uV 12:44:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.455 uVs 12:44:59 Integrated Voltage Measurement... 12:45:08 Voltage Offset Correction: v_off_ini = -106.586 uV, v_off_fin = -102.278 uV 12:45:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -467.705 uVs 12:45:08 Integrated Voltage Measurement... 12:45:17 Voltage Offset Correction: v_off_ini = -89.470 uV, v_off_fin = -92.689 uV 12:45:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.483 uVs 12:45:19 I2Y Average and RMS of Measurements VT = -470.088 +- 7.515 uVs I2Y = -43.248 +- 0.691 uTm^2 12:45:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:45:28 Integrated Voltage Measurement... 12:45:37 Voltage Offset Correction: v_off_ini = -106.228 uV, v_off_fin = -109.745 uV 12:45:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.029 uVs 12:45:37 Integrated Voltage Measurement... 12:45:46 Voltage Offset Correction: v_off_ini = -104.995 uV, v_off_fin = -97.245 uV 12:45:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.886 uVs 12:45:46 Integrated Voltage Measurement... 12:45:55 Voltage Offset Correction: v_off_ini = -97.680 uV, v_off_fin = -101.922 uV 12:45:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.164 uVs 12:45:55 Integrated Voltage Measurement... 12:46:04 Voltage Offset Correction: v_off_ini = -102.713 uV, v_off_fin = -98.780 uV 12:46:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.595 uVs 12:46:04 Integrated Voltage Measurement... 12:46:13 Voltage Offset Correction: v_off_ini = -103.939 uV, v_off_fin = -103.536 uV 12:46:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.753 uVs 12:46:13 Integrated Voltage Measurement... 12:46:22 Voltage Offset Correction: v_off_ini = -106.080 uV, v_off_fin = -90.423 uV 12:46:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.237 uVs 12:46:26 I1X Average and RMS of Measurements VT = -93.611 +- 3.897 uVs I1X = 18.722 +- 0.779 uTm 12:46:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:46:33 Integrated Voltage Measurement... 12:46:42 Voltage Offset Correction: v_off_ini = -104.499 uV, v_off_fin = -110.291 uV 12:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.062 uVs 12:46:42 Integrated Voltage Measurement... 12:46:51 Voltage Offset Correction: v_off_ini = -113.375 uV, v_off_fin = -105.963 uV 12:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.202 uVs 12:46:51 Integrated Voltage Measurement... 12:47:00 Voltage Offset Correction: v_off_ini = -110.408 uV, v_off_fin = -119.919 uV 12:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.886 uVs 12:47:00 Integrated Voltage Measurement... 12:47:09 Voltage Offset Correction: v_off_ini = -117.022 uV, v_off_fin = -106.468 uV 12:47:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.101 uVs 12:47:09 Integrated Voltage Measurement... 12:47:18 Voltage Offset Correction: v_off_ini = -105.271 uV, v_off_fin = -116.030 uV 12:47:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.236 uVs 12:47:18 Integrated Voltage Measurement... 12:47:27 Voltage Offset Correction: v_off_ini = -115.524 uV, v_off_fin = -110.687 uV 12:47:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.882 uVs 12:47:31 I1Y Average and RMS of Measurements VT = -211.062 +- 2.217 uVs I1Y = -42.212 +- 0.443 uTm 12:47:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:47:39 Integrated Voltage Measurement... 12:47:48 Voltage Offset Correction: v_off_ini = -110.120 uV, v_off_fin = -123.951 uV 12:47:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.215 uVs 12:47:48 Integrated Voltage Measurement... 12:47:57 Voltage Offset Correction: v_off_ini = -108.971 uV, v_off_fin = -100.197 uV 12:47:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.406 uVs 12:47:57 Integrated Voltage Measurement... 12:48:06 Voltage Offset Correction: v_off_ini = -111.335 uV, v_off_fin = -112.504 uV 12:48:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.218 uVs 12:48:06 Integrated Voltage Measurement... 12:48:15 Voltage Offset Correction: v_off_ini = -119.143 uV, v_off_fin = -101.194 uV 12:48:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.940 uVs 12:48:15 Integrated Voltage Measurement... 12:48:24 Voltage Offset Correction: v_off_ini = -93.590 uV, v_off_fin = -107.803 uV 12:48:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.665 uVs 12:48:24 Integrated Voltage Measurement... 12:48:33 Voltage Offset Correction: v_off_ini = -93.992 uV, v_off_fin = -83.741 uV 12:48:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.320 uVs 12:48:36 I2X Average and RMS of Measurements VT = -103.627 +- 9.775 uVs I2X = 9.534 +- 0.899 uTm^2 12:48:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:48:43 Integrated Voltage Measurement... 12:48:52 Voltage Offset Correction: v_off_ini = -105.335 uV, v_off_fin = -106.901 uV 12:48:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -443.145 uVs 12:48:52 Integrated Voltage Measurement... 12:49:01 Voltage Offset Correction: v_off_ini = -117.986 uV, v_off_fin = -125.083 uV 12:49:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.202 uVs 12:49:02 Integrated Voltage Measurement... 12:49:11 Voltage Offset Correction: v_off_ini = -115.965 uV, v_off_fin = -107.867 uV 12:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.210 uVs 12:49:11 Integrated Voltage Measurement... 12:49:20 Voltage Offset Correction: v_off_ini = -105.075 uV, v_off_fin = -103.645 uV 12:49:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 456.426 uVs 12:49:20 Integrated Voltage Measurement... 12:49:29 Voltage Offset Correction: v_off_ini = -94.112 uV, v_off_fin = -84.032 uV 12:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.497 uVs 12:49:29 Integrated Voltage Measurement... 12:49:38 Voltage Offset Correction: v_off_ini = -95.846 uV, v_off_fin = -93.149 uV 12:49:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 463.002 uVs 12:49:40 I2Y Average and RMS of Measurements VT = -456.414 +- 4.163 uVs I2Y = -41.990 +- 0.383 uTm^2 12:49:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:49:49 Integrated Voltage Measurement... 12:49:58 Voltage Offset Correction: v_off_ini = -102.446 uV, v_off_fin = -92.757 uV 12:49:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.969 uVs 12:49:58 Integrated Voltage Measurement... 12:50:07 Voltage Offset Correction: v_off_ini = -96.471 uV, v_off_fin = -97.018 uV 12:50:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.052 uVs 12:50:07 Integrated Voltage Measurement... 12:50:16 Voltage Offset Correction: v_off_ini = -87.831 uV, v_off_fin = -85.193 uV 12:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.675 uVs 12:50:16 Integrated Voltage Measurement... 12:50:25 Voltage Offset Correction: v_off_ini = -74.133 uV, v_off_fin = -89.477 uV 12:50:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.204 uVs 12:50:25 Integrated Voltage Measurement... 12:50:34 Voltage Offset Correction: v_off_ini = -109.825 uV, v_off_fin = -82.874 uV 12:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.322 uVs 12:50:34 Integrated Voltage Measurement... 12:50:43 Voltage Offset Correction: v_off_ini = -88.113 uV, v_off_fin = -91.377 uV 12:50:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.399 uVs 12:50:47 I1X Average and RMS of Measurements VT = -109.937 +- 6.092 uVs I1X = 21.987 +- 1.218 uTm 12:50:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:54 Integrated Voltage Measurement... 12:51:03 Voltage Offset Correction: v_off_ini = -107.272 uV, v_off_fin = -107.538 uV 12:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.818 uVs 12:51:03 Integrated Voltage Measurement... 12:51:12 Voltage Offset Correction: v_off_ini = -102.409 uV, v_off_fin = -87.619 uV 12:51:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.444 uVs 12:51:12 Integrated Voltage Measurement... 12:51:21 Voltage Offset Correction: v_off_ini = -88.869 uV, v_off_fin = -96.897 uV 12:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.990 uVs 12:51:21 Integrated Voltage Measurement... 12:51:30 Voltage Offset Correction: v_off_ini = -89.871 uV, v_off_fin = -81.898 uV 12:51:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.217 uVs 12:51:30 Integrated Voltage Measurement... 12:51:39 Voltage Offset Correction: v_off_ini = -79.303 uV, v_off_fin = -105.683 uV 12:51:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.134 uVs 12:51:39 Integrated Voltage Measurement... 12:51:48 Voltage Offset Correction: v_off_ini = -96.512 uV, v_off_fin = -83.080 uV 12:51:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.474 uVs 12:51:52 I1Y Average and RMS of Measurements VT = -203.846 +- 3.342 uVs I1Y = -40.771 +- 0.667 uTm 12:51:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:00 Integrated Voltage Measurement... 12:52:09 Voltage Offset Correction: v_off_ini = -89.683 uV, v_off_fin = -97.023 uV 12:52:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.891 uVs 12:52:09 Integrated Voltage Measurement... 12:52:18 Voltage Offset Correction: v_off_ini = -99.473 uV, v_off_fin = -101.617 uV 12:52:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.410 uVs 12:52:18 Integrated Voltage Measurement... 12:52:27 Voltage Offset Correction: v_off_ini = -109.844 uV, v_off_fin = -122.542 uV 12:52:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.480 uVs 12:52:27 Integrated Voltage Measurement... 12:52:36 Voltage Offset Correction: v_off_ini = -111.030 uV, v_off_fin = -107.376 uV 12:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.831 uVs 12:52:36 Integrated Voltage Measurement... 12:52:45 Voltage Offset Correction: v_off_ini = -103.558 uV, v_off_fin = -117.968 uV 12:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.256 uVs 12:52:45 Integrated Voltage Measurement... 12:52:54 Voltage Offset Correction: v_off_ini = -105.430 uV, v_off_fin = -105.761 uV 12:52:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.260 uVs 12:52:57 I2X Average and RMS of Measurements VT = -113.354 +- 11.601 uVs I2X = 10.429 +- 1.067 uTm^2 12:53:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:05 Integrated Voltage Measurement... 12:53:14 Voltage Offset Correction: v_off_ini = -113.117 uV, v_off_fin = -111.336 uV 12:53:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.279 uVs 12:53:14 Integrated Voltage Measurement... 12:53:23 Voltage Offset Correction: v_off_ini = -107.459 uV, v_off_fin = -98.171 uV 12:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 437.176 uVs 12:53:23 Integrated Voltage Measurement... 12:53:32 Voltage Offset Correction: v_off_ini = -100.593 uV, v_off_fin = -109.397 uV 12:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.710 uVs 12:53:32 Integrated Voltage Measurement... 12:53:41 Voltage Offset Correction: v_off_ini = -112.934 uV, v_off_fin = -127.988 uV 12:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.206 uVs 12:53:41 Integrated Voltage Measurement... 12:53:50 Voltage Offset Correction: v_off_ini = -126.745 uV, v_off_fin = -126.330 uV 12:53:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -428.914 uVs 12:53:50 Integrated Voltage Measurement... 12:53:59 Voltage Offset Correction: v_off_ini = -109.238 uV, v_off_fin = -114.929 uV 12:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.615 uVs 12:54:01 I2Y Average and RMS of Measurements VT = -442.983 +- 5.643 uVs I2Y = -40.755 +- 0.519 uTm^2 12:54:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:54:10 Integrated Voltage Measurement... 12:54:19 Voltage Offset Correction: v_off_ini = -104.743 uV, v_off_fin = -118.230 uV 12:54:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.408 uVs 12:54:19 Integrated Voltage Measurement... 12:54:28 Voltage Offset Correction: v_off_ini = -107.164 uV, v_off_fin = -112.899 uV 12:54:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 128.682 uVs 12:54:28 Integrated Voltage Measurement... 12:54:37 Voltage Offset Correction: v_off_ini = -106.555 uV, v_off_fin = -111.420 uV 12:54:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.380 uVs 12:54:37 Integrated Voltage Measurement... 12:54:46 Voltage Offset Correction: v_off_ini = -103.035 uV, v_off_fin = -95.318 uV 12:54:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.815 uVs 12:54:46 Integrated Voltage Measurement... 12:54:55 Voltage Offset Correction: v_off_ini = -110.004 uV, v_off_fin = -102.396 uV 12:54:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.152 uVs 12:54:55 Integrated Voltage Measurement... 12:55:04 Voltage Offset Correction: v_off_ini = -98.420 uV, v_off_fin = -97.815 uV 12:55:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.185 uVs 12:55:08 I1X Average and RMS of Measurements VT = -121.104 +- 3.190 uVs I1X = 24.222 +- 0.638 uTm 12:55:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:55:15 Integrated Voltage Measurement... 12:55:24 Voltage Offset Correction: v_off_ini = -102.985 uV, v_off_fin = -119.677 uV 12:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.373 uVs 12:55:24 Integrated Voltage Measurement... 12:55:33 Voltage Offset Correction: v_off_ini = -94.995 uV, v_off_fin = -90.407 uV 12:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.482 uVs 12:55:33 Integrated Voltage Measurement... 12:55:42 Voltage Offset Correction: v_off_ini = -93.983 uV, v_off_fin = -100.274 uV 12:55:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.894 uVs 12:55:42 Integrated Voltage Measurement... 12:55:51 Voltage Offset Correction: v_off_ini = -89.329 uV, v_off_fin = -84.507 uV 12:55:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.629 uVs 12:55:51 Integrated Voltage Measurement... 12:56:00 Voltage Offset Correction: v_off_ini = -77.599 uV, v_off_fin = -97.643 uV 12:56:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.265 uVs 12:56:00 Integrated Voltage Measurement... 12:56:09 Voltage Offset Correction: v_off_ini = -86.257 uV, v_off_fin = -73.368 uV 12:56:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.089 uVs 12:56:13 I1Y Average and RMS of Measurements VT = -204.456 +- 2.916 uVs I1Y = -40.891 +- 0.583 uTm 12:56:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:56:21 Integrated Voltage Measurement... 12:56:30 Voltage Offset Correction: v_off_ini = -109.102 uV, v_off_fin = -94.928 uV 12:56:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.562 uVs 12:56:30 Integrated Voltage Measurement... 12:56:39 Voltage Offset Correction: v_off_ini = -88.273 uV, v_off_fin = -82.317 uV 12:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.042 uVs 12:56:39 Integrated Voltage Measurement... 12:56:48 Voltage Offset Correction: v_off_ini = -89.956 uV, v_off_fin = -95.823 uV 12:56:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -116.176 uVs 12:56:48 Integrated Voltage Measurement... 12:56:57 Voltage Offset Correction: v_off_ini = -84.051 uV, v_off_fin = -74.281 uV 12:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.047 uVs 12:56:57 Integrated Voltage Measurement... 12:57:06 Voltage Offset Correction: v_off_ini = -84.979 uV, v_off_fin = -92.654 uV 12:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.438 uVs 12:57:06 Integrated Voltage Measurement... 12:57:15 Voltage Offset Correction: v_off_ini = -60.416 uV, v_off_fin = -68.611 uV 12:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.725 uVs 12:57:18 I2X Average and RMS of Measurements VT = -126.332 +- 6.205 uVs I2X = 11.623 +- 0.571 uTm^2 12:57:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:57:26 Integrated Voltage Measurement... 12:57:35 Voltage Offset Correction: v_off_ini = -74.540 uV, v_off_fin = -66.792 uV 12:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -438.425 uVs 12:57:35 Integrated Voltage Measurement... 12:57:44 Voltage Offset Correction: v_off_ini = -76.346 uV, v_off_fin = -72.395 uV 12:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.695 uVs 12:57:44 Integrated Voltage Measurement... 12:57:53 Voltage Offset Correction: v_off_ini = -64.042 uV, v_off_fin = -59.629 uV 12:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.661 uVs 12:57:53 Integrated Voltage Measurement... 12:58:02 Voltage Offset Correction: v_off_ini = -59.021 uV, v_off_fin = -59.777 uV 12:58:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 447.917 uVs 12:58:02 Integrated Voltage Measurement... 12:58:11 Voltage Offset Correction: v_off_ini = -57.193 uV, v_off_fin = -63.740 uV 12:58:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -450.534 uVs 12:58:11 Integrated Voltage Measurement... 12:58:20 Voltage Offset Correction: v_off_ini = -62.993 uV, v_off_fin = -52.163 uV 12:58:20 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = 434.835 uVs 12:58:22 I2Y Average and RMS of Measurements VT = -445.844 +- 4.557 uVs I2Y = -41.020 +- 0.419 uTm^2 12:58:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:58:31 Integrated Voltage Measurement... 12:58:40 Voltage Offset Correction: v_off_ini = -63.073 uV, v_off_fin = -73.544 uV 12:58:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.327 uVs 12:58:40 Integrated Voltage Measurement... 12:58:49 Voltage Offset Correction: v_off_ini = -58.479 uV, v_off_fin = -50.967 uV 12:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.138 uVs 12:58:49 Integrated Voltage Measurement... 12:58:58 Voltage Offset Correction: v_off_ini = -58.557 uV, v_off_fin = -68.021 uV 12:58:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.114 uVs 12:58:58 Integrated Voltage Measurement... 12:59:07 Voltage Offset Correction: v_off_ini = -62.757 uV, v_off_fin = -64.501 uV 12:59:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.362 uVs 12:59:07 Integrated Voltage Measurement... 12:59:16 Voltage Offset Correction: v_off_ini = -75.876 uV, v_off_fin = -67.315 uV 12:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.100 uVs 12:59:16 Integrated Voltage Measurement... 12:59:25 Voltage Offset Correction: v_off_ini = -61.236 uV, v_off_fin = -64.285 uV 12:59:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.375 uVs 12:59:30 I1X Average and RMS of Measurements VT = -136.903 +- 6.277 uVs I1X = 27.381 +- 1.255 uTm 12:59:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:59:36 Integrated Voltage Measurement... 12:59:45 Voltage Offset Correction: v_off_ini = -69.079 uV, v_off_fin = -80.596 uV 12:59:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.064 uVs 12:59:45 Integrated Voltage Measurement... 12:59:54 Voltage Offset Correction: v_off_ini = -82.055 uV, v_off_fin = -68.826 uV 12:59:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 195.543 uVs 12:59:54 Integrated Voltage Measurement... 13:00:03 Voltage Offset Correction: v_off_ini = -68.556 uV, v_off_fin = -71.128 uV 13:00:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.045 uVs 13:00:03 Integrated Voltage Measurement... 13:00:12 Voltage Offset Correction: v_off_ini = -51.272 uV, v_off_fin = -46.130 uV 13:00:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.048 uVs 13:00:12 Integrated Voltage Measurement... 13:00:21 Voltage Offset Correction: v_off_ini = -68.218 uV, v_off_fin = -73.558 uV 13:00:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.874 uVs 13:00:21 Integrated Voltage Measurement... 13:00:30 Voltage Offset Correction: v_off_ini = -82.393 uV, v_off_fin = -65.775 uV 13:00:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.197 uVs 13:00:35 I1Y Average and RMS of Measurements VT = -192.128 +- 6.589 uVs I1Y = -38.426 +- 1.317 uTm 13:00:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:00:42 Integrated Voltage Measurement... 13:00:51 Voltage Offset Correction: v_off_ini = -67.338 uV, v_off_fin = -69.781 uV 13:00:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.385 uVs 13:00:51 Integrated Voltage Measurement... 13:01:00 Voltage Offset Correction: v_off_ini = -64.775 uV, v_off_fin = -62.447 uV 13:01:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.810 uVs 13:01:01 Integrated Voltage Measurement... 13:01:10 Voltage Offset Correction: v_off_ini = -66.588 uV, v_off_fin = -73.168 uV 13:01:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.950 uVs 13:01:10 Integrated Voltage Measurement... 13:01:19 Voltage Offset Correction: v_off_ini = -55.698 uV, v_off_fin = -54.135 uV 13:01:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.796 uVs 13:01:19 Integrated Voltage Measurement... 13:01:28 Voltage Offset Correction: v_off_ini = -53.357 uV, v_off_fin = -66.826 uV 13:01:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -155.559 uVs 13:01:28 Integrated Voltage Measurement... 13:01:37 Voltage Offset Correction: v_off_ini = -55.606 uV, v_off_fin = -45.422 uV 13:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.674 uVs 13:01:39 I2X Average and RMS of Measurements VT = -136.862 +- 5.679 uVs I2X = 12.592 +- 0.522 uTm^2 13:01:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:01:47 Integrated Voltage Measurement... 13:01:56 Voltage Offset Correction: v_off_ini = -69.613 uV, v_off_fin = -53.497 uV 13:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -441.396 uVs 13:01:56 Integrated Voltage Measurement... 13:02:05 Voltage Offset Correction: v_off_ini = -55.386 uV, v_off_fin = -52.098 uV 13:02:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 450.253 uVs 13:02:05 Integrated Voltage Measurement... 13:02:14 Voltage Offset Correction: v_off_ini = -50.305 uV, v_off_fin = -44.979 uV 13:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.716 uVs 13:02:14 Integrated Voltage Measurement... 13:02:23 Voltage Offset Correction: v_off_ini = -41.894 uV, v_off_fin = -42.666 uV 13:02:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 428.064 uVs 13:02:23 Integrated Voltage Measurement... 13:02:32 Voltage Offset Correction: v_off_ini = -54.120 uV, v_off_fin = -53.107 uV 13:02:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -432.580 uVs 13:02:32 Integrated Voltage Measurement... 13:02:41 Voltage Offset Correction: v_off_ini = -64.026 uV, v_off_fin = -62.076 uV 13:02:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 435.932 uVs 13:02:43 I2Y Average and RMS of Measurements VT = -438.157 +- 5.422 uVs I2Y = -40.311 +- 0.500 uTm^2 13:02:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:02:56 Integrated Voltage Measurement... 13:03:04 Voltage Offset Correction: v_off_ini = -43.954 uV, v_off_fin = -46.948 uV 13:03:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -110.688 uVs 13:03:05 Integrated Voltage Measurement... 13:03:14 Voltage Offset Correction: v_off_ini = -39.615 uV, v_off_fin = -49.132 uV 13:03:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.513 uVs 13:03:14 Integrated Voltage Measurement... 13:03:23 Voltage Offset Correction: v_off_ini = -48.630 uV, v_off_fin = -54.051 uV 13:03:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -93.044 uVs 13:03:23 Integrated Voltage Measurement... 13:03:32 Voltage Offset Correction: v_off_ini = -56.763 uV, v_off_fin = -54.931 uV 13:03:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 84.293 uVs 13:03:32 Integrated Voltage Measurement... 13:03:41 Voltage Offset Correction: v_off_ini = -56.574 uV, v_off_fin = -56.692 uV 13:03:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -101.076 uVs 13:03:41 Integrated Voltage Measurement... 13:03:50 Voltage Offset Correction: v_off_ini = -60.643 uV, v_off_fin = -51.375 uV 13:03:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 104.427 uVs 13:03:54 I1X Average and RMS of Measurements VT = -96.007 +- 5.765 uVs I1X = 19.204 +- 1.154 uTm 13:03:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:04:01 Integrated Voltage Measurement... 13:04:10 Voltage Offset Correction: v_off_ini = -66.591 uV, v_off_fin = -61.855 uV 13:04:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -216.425 uVs 13:04:10 Integrated Voltage Measurement... 13:04:19 Voltage Offset Correction: v_off_ini = -70.126 uV, v_off_fin = -58.489 uV 13:04:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.620 uVs 13:04:19 Integrated Voltage Measurement... 13:04:28 Voltage Offset Correction: v_off_ini = -73.260 uV, v_off_fin = -78.265 uV 13:04:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.845 uVs 13:04:28 Integrated Voltage Measurement... 13:04:37 Voltage Offset Correction: v_off_ini = -58.878 uV, v_off_fin = -67.048 uV 13:04:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.381 uVs 13:04:37 Integrated Voltage Measurement... 13:04:46 Voltage Offset Correction: v_off_ini = -59.642 uV, v_off_fin = -75.958 uV 13:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.980 uVs 13:04:46 Integrated Voltage Measurement... 13:04:55 Voltage Offset Correction: v_off_ini = -61.747 uV, v_off_fin = -64.580 uV 13:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.192 uVs 13:04:59 I1Y Average and RMS of Measurements VT = -203.240 +- 4.884 uVs I1Y = -40.650 +- 0.979 uTm 13:05:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:05:04 Integrated Voltage Measurement... 13:05:13 Voltage Offset Correction: v_off_ini = -72.375 uV, v_off_fin = -70.148 uV 13:05:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.153 uVs 13:05:13 Integrated Voltage Measurement... 13:05:22 Voltage Offset Correction: v_off_ini = -66.894 uV, v_off_fin = -67.910 uV 13:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.413 uVs 13:05:22 Integrated Voltage Measurement... 13:05:31 Voltage Offset Correction: v_off_ini = -65.244 uV, v_off_fin = -77.078 uV 13:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.021 uVs 13:05:31 Integrated Voltage Measurement... 13:05:40 Voltage Offset Correction: v_off_ini = -71.170 uV, v_off_fin = -66.719 uV 13:05:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.373 uVs 13:05:40 Integrated Voltage Measurement... 13:05:49 Voltage Offset Correction: v_off_ini = -68.449 uV, v_off_fin = -84.481 uV 13:05:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.197 uVs 13:05:49 Integrated Voltage Measurement... 13:05:58 Voltage Offset Correction: v_off_ini = -65.915 uV, v_off_fin = -59.282 uV 13:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.937 uVs 13:06:01 I2X Average and RMS of Measurements VT = -99.182 +- 0.767 uVs I2X = 9.125 +- 0.071 uTm^2 13:06:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:06:06 Integrated Voltage Measurement... 13:06:15 Voltage Offset Correction: v_off_ini = -64.423 uV, v_off_fin = -61.012 uV 13:06:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.280 uVs 13:06:15 Integrated Voltage Measurement... 13:06:24 Voltage Offset Correction: v_off_ini = -69.993 uV, v_off_fin = -63.557 uV 13:06:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.790 uVs 13:06:24 Integrated Voltage Measurement... 13:06:33 Voltage Offset Correction: v_off_ini = -61.870 uV, v_off_fin = -61.456 uV 13:06:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.886 uVs 13:06:33 Integrated Voltage Measurement... 13:06:42 Voltage Offset Correction: v_off_ini = -51.532 uV, v_off_fin = -69.126 uV 13:06:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.482 uVs 13:06:42 Integrated Voltage Measurement... 13:06:51 Voltage Offset Correction: v_off_ini = -59.596 uV, v_off_fin = -77.717 uV 13:06:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -431.382 uVs 13:06:51 Integrated Voltage Measurement... 13:07:00 Voltage Offset Correction: v_off_ini = -67.546 uV, v_off_fin = -60.123 uV 13:07:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 424.395 uVs 13:07:03 I2Y Average and RMS of Measurements VT = -430.036 +- 1.696 uVs I2Y = -39.563 +- 0.156 uTm^2 13:07:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:07:11 Integrated Voltage Measurement... 13:07:20 Voltage Offset Correction: v_off_ini = -38.792 uV, v_off_fin = -55.357 uV 13:07:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.936 uVs 13:07:20 Integrated Voltage Measurement... 13:07:29 Voltage Offset Correction: v_off_ini = -51.911 uV, v_off_fin = -51.448 uV 13:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.746 uVs 13:07:29 Integrated Voltage Measurement... 13:07:38 Voltage Offset Correction: v_off_ini = -45.443 uV, v_off_fin = -62.950 uV 13:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.980 uVs 13:07:38 Integrated Voltage Measurement... 13:07:47 Voltage Offset Correction: v_off_ini = -56.075 uV, v_off_fin = -44.117 uV 13:07:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 122.296 uVs 13:07:47 Integrated Voltage Measurement... 13:07:56 Voltage Offset Correction: v_off_ini = -50.580 uV, v_off_fin = -59.954 uV 13:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.919 uVs 13:07:56 Integrated Voltage Measurement... 13:08:05 Voltage Offset Correction: v_off_ini = -61.557 uV, v_off_fin = -52.528 uV 13:08:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 100.248 uVs 13:08:09 I1X Average and RMS of Measurements VT = -109.854 +- 9.775 uVs I1X = 21.972 +- 1.956 uTm 13:08:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:08:16 Integrated Voltage Measurement... 13:08:25 Voltage Offset Correction: v_off_ini = -76.573 uV, v_off_fin = -92.492 uV 13:08:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.261 uVs 13:08:25 Integrated Voltage Measurement... 13:08:34 Voltage Offset Correction: v_off_ini = -68.105 uV, v_off_fin = -60.012 uV 13:08:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.328 uVs 13:08:34 Integrated Voltage Measurement... 13:08:43 Voltage Offset Correction: v_off_ini = -78.213 uV, v_off_fin = -81.350 uV 13:08:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.183 uVs 13:08:43 Integrated Voltage Measurement... 13:08:52 Voltage Offset Correction: v_off_ini = -75.332 uV, v_off_fin = -53.761 uV 13:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.478 uVs 13:08:52 Integrated Voltage Measurement... 13:09:01 Voltage Offset Correction: v_off_ini = -66.344 uV, v_off_fin = -70.904 uV 13:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.674 uVs 13:09:01 Integrated Voltage Measurement... 13:09:10 Voltage Offset Correction: v_off_ini = -75.693 uV, v_off_fin = -69.687 uV 13:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.368 uVs 13:09:14 I1Y Average and RMS of Measurements VT = -207.549 +- 5.505 uVs I1Y = -41.510 +- 1.101 uTm 13:09:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:09:20 Integrated Voltage Measurement... 13:09:29 Voltage Offset Correction: v_off_ini = -61.530 uV, v_off_fin = -70.110 uV 13:09:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.751 uVs 13:09:29 Integrated Voltage Measurement... 13:09:38 Voltage Offset Correction: v_off_ini = -60.465 uV, v_off_fin = -52.553 uV 13:09:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.244 uVs 13:09:38 Integrated Voltage Measurement... 13:09:47 Voltage Offset Correction: v_off_ini = -57.343 uV, v_off_fin = -51.801 uV 13:09:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.871 uVs 13:09:47 Integrated Voltage Measurement... 13:09:56 Voltage Offset Correction: v_off_ini = -27.836 uV, v_off_fin = -29.882 uV 13:09:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.804 uVs 13:09:56 Integrated Voltage Measurement... 13:10:05 Voltage Offset Correction: v_off_ini = -52.802 uV, v_off_fin = -71.054 uV 13:10:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.005 uVs 13:10:05 Integrated Voltage Measurement... 13:10:14 Voltage Offset Correction: v_off_ini = -54.827 uV, v_off_fin = -59.500 uV 13:10:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.840 uVs 13:10:16 I2X Average and RMS of Measurements VT = -106.919 +- 2.773 uVs I2X = 9.837 +- 0.255 uTm^2 13:10:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:10:21 Integrated Voltage Measurement... 13:10:30 Voltage Offset Correction: v_off_ini = -77.050 uV, v_off_fin = -78.981 uV 13:10:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -451.595 uVs 13:10:31 Integrated Voltage Measurement... 13:10:40 Voltage Offset Correction: v_off_ini = -88.003 uV, v_off_fin = -74.577 uV 13:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 433.164 uVs 13:10:40 Integrated Voltage Measurement... 13:10:49 Voltage Offset Correction: v_off_ini = -71.920 uV, v_off_fin = -71.044 uV 13:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.193 uVs 13:10:49 Integrated Voltage Measurement... 13:10:58 Voltage Offset Correction: v_off_ini = -82.709 uV, v_off_fin = -81.680 uV 13:10:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.387 uVs 13:10:58 Integrated Voltage Measurement... 13:11:07 Voltage Offset Correction: v_off_ini = -83.734 uV, v_off_fin = -81.336 uV 13:11:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.971 uVs 13:11:07 Integrated Voltage Measurement... 13:11:16 Voltage Offset Correction: v_off_ini = -81.156 uV, v_off_fin = -94.114 uV 13:11:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.071 uVs 13:11:18 I2Y Average and RMS of Measurements VT = -441.730 +- 5.640 uVs I2Y = -40.640 +- 0.519 uTm^2 13:11:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:27 Integrated Voltage Measurement... 13:11:36 Voltage Offset Correction: v_off_ini = -82.620 uV, v_off_fin = -90.154 uV 13:11:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.752 uVs 13:11:36 Integrated Voltage Measurement... 13:11:45 Voltage Offset Correction: v_off_ini = -96.223 uV, v_off_fin = -79.023 uV 13:11:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.655 uVs 13:11:45 Integrated Voltage Measurement... 13:11:54 Voltage Offset Correction: v_off_ini = -85.838 uV, v_off_fin = -78.493 uV 13:11:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.045 uVs 13:11:54 Integrated Voltage Measurement... 13:12:03 Voltage Offset Correction: v_off_ini = -88.911 uV, v_off_fin = -78.017 uV 13:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.152 uVs 13:12:03 Integrated Voltage Measurement... 13:12:12 Voltage Offset Correction: v_off_ini = -87.238 uV, v_off_fin = -90.434 uV 13:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.851 uVs 13:12:12 Integrated Voltage Measurement... 13:12:21 Voltage Offset Correction: v_off_ini = -84.551 uV, v_off_fin = -79.592 uV 13:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.612 uVs 13:12:25 I1X Average and RMS of Measurements VT = -122.011 +- 11.315 uVs I1X = 24.402 +- 2.263 uTm 13:12:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:32 Integrated Voltage Measurement... 13:12:41 Voltage Offset Correction: v_off_ini = -98.399 uV, v_off_fin = -92.267 uV 13:12:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.732 uVs 13:12:41 Integrated Voltage Measurement... 13:12:50 Voltage Offset Correction: v_off_ini = -86.484 uV, v_off_fin = -79.728 uV 13:12:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.830 uVs 13:12:50 Integrated Voltage Measurement... 13:12:59 Voltage Offset Correction: v_off_ini = -73.346 uV, v_off_fin = -84.104 uV 13:12:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.045 uVs 13:12:59 Integrated Voltage Measurement... 13:13:08 Voltage Offset Correction: v_off_ini = -71.849 uV, v_off_fin = -65.613 uV 13:13:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.308 uVs 13:13:08 Integrated Voltage Measurement... 13:13:17 Voltage Offset Correction: v_off_ini = -82.703 uV, v_off_fin = -90.783 uV 13:13:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.843 uVs 13:13:17 Integrated Voltage Measurement... 13:13:26 Voltage Offset Correction: v_off_ini = -72.458 uV, v_off_fin = -63.371 uV 13:13:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.566 uVs 13:13:30 I1Y Average and RMS of Measurements VT = -204.054 +- 5.779 uVs I1Y = -40.811 +- 1.156 uTm 13:13:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:35 Integrated Voltage Measurement... 13:13:44 Voltage Offset Correction: v_off_ini = -72.367 uV, v_off_fin = -95.542 uV 13:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.929 uVs 13:13:44 Integrated Voltage Measurement... 13:13:53 Voltage Offset Correction: v_off_ini = -83.958 uV, v_off_fin = -67.131 uV 13:13:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.443 uVs 13:13:53 Integrated Voltage Measurement... 13:14:02 Voltage Offset Correction: v_off_ini = -90.775 uV, v_off_fin = -99.820 uV 13:14:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -100.078 uVs 13:14:02 Integrated Voltage Measurement... 13:14:11 Voltage Offset Correction: v_off_ini = -93.839 uV, v_off_fin = -86.130 uV 13:14:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.498 uVs 13:14:11 Integrated Voltage Measurement... 13:14:20 Voltage Offset Correction: v_off_ini = -79.898 uV, v_off_fin = -77.575 uV 13:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.007 uVs 13:14:20 Integrated Voltage Measurement... 13:14:29 Voltage Offset Correction: v_off_ini = -74.292 uV, v_off_fin = -62.972 uV 13:14:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.407 uVs 13:14:32 I2X Average and RMS of Measurements VT = -111.393 +- 4.464 uVs I2X = 10.249 +- 0.411 uTm^2 13:14:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:37 Integrated Voltage Measurement... 13:14:46 Voltage Offset Correction: v_off_ini = -79.189 uV, v_off_fin = -83.041 uV 13:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.751 uVs 13:14:46 Integrated Voltage Measurement... 13:14:55 Voltage Offset Correction: v_off_ini = -92.614 uV, v_off_fin = -89.103 uV 13:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.659 uVs 13:14:55 Integrated Voltage Measurement... 13:15:04 Voltage Offset Correction: v_off_ini = -85.518 uV, v_off_fin = -86.269 uV 13:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.661 uVs 13:15:04 Integrated Voltage Measurement... 13:15:13 Voltage Offset Correction: v_off_ini = -98.543 uV, v_off_fin = -95.423 uV 13:15:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.092 uVs 13:15:13 Integrated Voltage Measurement... 13:15:22 Voltage Offset Correction: v_off_ini = -82.726 uV, v_off_fin = -89.181 uV 13:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.391 uVs 13:15:22 Integrated Voltage Measurement... 13:15:31 Voltage Offset Correction: v_off_ini = -82.606 uV, v_off_fin = -88.529 uV 13:15:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.889 uVs 13:15:33 I2Y Average and RMS of Measurements VT = -450.574 +- 5.300 uVs I2Y = -41.453 +- 0.488 uTm^2 13:15:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:15:42 Integrated Voltage Measurement... 13:15:51 Voltage Offset Correction: v_off_ini = -87.688 uV, v_off_fin = -78.613 uV 13:15:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.224 uVs 13:15:51 Integrated Voltage Measurement... 13:16:00 Voltage Offset Correction: v_off_ini = -81.896 uV, v_off_fin = -77.552 uV 13:16:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.958 uVs 13:16:00 Integrated Voltage Measurement... 13:16:09 Voltage Offset Correction: v_off_ini = -107.764 uV, v_off_fin = -101.163 uV 13:16:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -116.898 uVs 13:16:09 Integrated Voltage Measurement... 13:16:18 Voltage Offset Correction: v_off_ini = -111.233 uV, v_off_fin = -106.660 uV 13:16:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.071 uVs 13:16:18 Integrated Voltage Measurement... 13:16:27 Voltage Offset Correction: v_off_ini = -100.237 uV, v_off_fin = -109.034 uV 13:16:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.158 uVs 13:16:27 Integrated Voltage Measurement... 13:16:36 Voltage Offset Correction: v_off_ini = -110.275 uV, v_off_fin = -101.324 uV 13:16:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.561 uVs 13:16:40 I1X Average and RMS of Measurements VT = -118.478 +- 7.391 uVs I1X = 23.697 +- 1.479 uTm 13:16:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:16:47 Integrated Voltage Measurement... 13:16:56 Voltage Offset Correction: v_off_ini = -103.994 uV, v_off_fin = -110.115 uV 13:16:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -200.847 uVs 13:16:56 Integrated Voltage Measurement... 13:17:04 Voltage Offset Correction: v_off_ini = -101.899 uV, v_off_fin = -78.136 uV 13:17:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.972 uVs 13:17:05 Integrated Voltage Measurement... 13:17:13 Voltage Offset Correction: v_off_ini = -97.905 uV, v_off_fin = -105.801 uV 13:17:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.650 uVs 13:17:14 Integrated Voltage Measurement... 13:17:22 Voltage Offset Correction: v_off_ini = -87.334 uV, v_off_fin = -75.686 uV 13:17:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.221 uVs 13:17:23 Integrated Voltage Measurement... 13:17:31 Voltage Offset Correction: v_off_ini = -82.799 uV, v_off_fin = -97.120 uV 13:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.316 uVs 13:17:32 Integrated Voltage Measurement... 13:17:40 Voltage Offset Correction: v_off_ini = -94.013 uV, v_off_fin = -85.396 uV 13:17:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.064 uVs 13:17:45 I1Y Average and RMS of Measurements VT = -210.678 +- 3.297 uVs I1Y = -42.135 +- 0.657 uTm 13:17:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:17:50 Integrated Voltage Measurement... 13:17:59 Voltage Offset Correction: v_off_ini = -84.292 uV, v_off_fin = -80.792 uV 13:17:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.877 uVs 13:17:59 Integrated Voltage Measurement... 13:18:08 Voltage Offset Correction: v_off_ini = -68.759 uV, v_off_fin = -52.976 uV 13:18:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.866 uVs 13:18:08 Integrated Voltage Measurement... 13:18:17 Voltage Offset Correction: v_off_ini = -71.501 uV, v_off_fin = -87.649 uV 13:18:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.428 uVs 13:18:17 Integrated Voltage Measurement... 13:18:26 Voltage Offset Correction: v_off_ini = -81.060 uV, v_off_fin = -74.872 uV 13:18:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.505 uVs 13:18:26 Integrated Voltage Measurement... 13:18:35 Voltage Offset Correction: v_off_ini = -76.703 uV, v_off_fin = -77.997 uV 13:18:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.316 uVs 13:18:35 Integrated Voltage Measurement... 13:18:44 Voltage Offset Correction: v_off_ini = -87.370 uV, v_off_fin = -97.375 uV 13:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.062 uVs 13:18:46 I2X Average and RMS of Measurements VT = -120.176 +- 2.045 uVs I2X = 11.056 +- 0.188 uTm^2 13:18:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:18:51 Integrated Voltage Measurement... 13:19:00 Voltage Offset Correction: v_off_ini = -95.552 uV, v_off_fin = -94.039 uV 13:19:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -442.312 uVs 13:19:00 Integrated Voltage Measurement... 13:19:09 Voltage Offset Correction: v_off_ini = -68.395 uV, v_off_fin = -75.545 uV 13:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.049 uVs 13:19:10 Integrated Voltage Measurement... 13:19:18 Voltage Offset Correction: v_off_ini = -79.666 uV, v_off_fin = -90.191 uV 13:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.128 uVs 13:19:19 Integrated Voltage Measurement... 13:19:28 Voltage Offset Correction: v_off_ini = -79.381 uV, v_off_fin = -85.097 uV 13:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 465.002 uVs 13:19:28 Integrated Voltage Measurement... 13:19:37 Voltage Offset Correction: v_off_ini = -84.335 uV, v_off_fin = -74.654 uV 13:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.495 uVs 13:19:37 Integrated Voltage Measurement... 13:19:46 Voltage Offset Correction: v_off_ini = -82.747 uV, v_off_fin = -76.122 uV 13:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 433.863 uVs 13:19:48 I2Y Average and RMS of Measurements VT = -450.641 +- 7.373 uVs I2Y = -41.460 +- 0.678 uTm^2 13:19:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:19:56 Integrated Voltage Measurement... 13:20:05 Voltage Offset Correction: v_off_ini = -68.866 uV, v_off_fin = -77.250 uV 13:20:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.713 uVs 13:20:05 Integrated Voltage Measurement... 13:20:14 Voltage Offset Correction: v_off_ini = -83.919 uV, v_off_fin = -80.715 uV 13:20:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.327 uVs 13:20:14 Integrated Voltage Measurement... 13:20:23 Voltage Offset Correction: v_off_ini = -76.556 uV, v_off_fin = -89.808 uV 13:20:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.742 uVs 13:20:23 Integrated Voltage Measurement... 13:20:32 Voltage Offset Correction: v_off_ini = -72.655 uV, v_off_fin = -71.915 uV 13:20:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.635 uVs 13:20:32 Integrated Voltage Measurement... 13:20:41 Voltage Offset Correction: v_off_ini = -76.378 uV, v_off_fin = -82.065 uV 13:20:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.316 uVs 13:20:41 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = -89.901 uV, v_off_fin = -85.661 uV 13:20:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.762 uVs 13:20:55 I1X Average and RMS of Measurements VT = -114.916 +- 9.493 uVs I1X = 22.983 +- 1.899 uTm 13:20:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:21:01 Integrated Voltage Measurement... 13:21:10 Voltage Offset Correction: v_off_ini = -81.711 uV, v_off_fin = -90.594 uV 13:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.276 uVs 13:21:10 Integrated Voltage Measurement... 13:21:19 Voltage Offset Correction: v_off_ini = -79.843 uV, v_off_fin = -69.412 uV 13:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.348 uVs 13:21:19 Integrated Voltage Measurement... 13:21:28 Voltage Offset Correction: v_off_ini = -82.042 uV, v_off_fin = -75.017 uV 13:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.711 uVs 13:21:28 Integrated Voltage Measurement... 13:21:37 Voltage Offset Correction: v_off_ini = -58.535 uV, v_off_fin = -49.102 uV 13:21:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.781 uVs 13:21:37 Integrated Voltage Measurement... 13:21:46 Voltage Offset Correction: v_off_ini = -57.912 uV, v_off_fin = -69.771 uV 13:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.307 uVs 13:21:46 Integrated Voltage Measurement... 13:21:55 Voltage Offset Correction: v_off_ini = -62.101 uV, v_off_fin = -52.808 uV 13:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.677 uVs 13:21:59 I1Y Average and RMS of Measurements VT = -209.350 +- 3.599 uVs I1Y = -41.866 +- 0.719 uTm 13:22:02 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:22:05 Integrated Voltage Measurement... 13:22:14 Voltage Offset Correction: v_off_ini = -53.328 uV, v_off_fin = -56.986 uV 13:22:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.396 uVs 13:22:14 Integrated Voltage Measurement... 13:22:23 Voltage Offset Correction: v_off_ini = -53.433 uV, v_off_fin = -29.428 uV 13:22:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.058 uVs 13:22:23 Integrated Voltage Measurement... 13:22:32 Voltage Offset Correction: v_off_ini = -39.106 uV, v_off_fin = -35.299 uV 13:22:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.484 uVs 13:22:32 Integrated Voltage Measurement... 13:22:41 Voltage Offset Correction: v_off_ini = -35.263 uV, v_off_fin = -15.086 uV 13:22:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.438 uVs 13:22:41 Integrated Voltage Measurement... 13:22:50 Voltage Offset Correction: v_off_ini = -22.246 uV, v_off_fin = -42.222 uV 13:22:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.406 uVs 13:22:50 Integrated Voltage Measurement... 13:22:59 Voltage Offset Correction: v_off_ini = -37.245 uV, v_off_fin = -20.281 uV 13:22:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.700 uVs 13:23:01 I2X Average and RMS of Measurements VT = -116.414 +- 7.019 uVs I2X = 10.710 +- 0.646 uTm^2 13:23:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:23:06 Integrated Voltage Measurement... 13:23:15 Voltage Offset Correction: v_off_ini = -26.068 uV, v_off_fin = -38.125 uV 13:23:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -465.807 uVs 13:23:15 Integrated Voltage Measurement... 13:23:24 Voltage Offset Correction: v_off_ini = -25.286 uV, v_off_fin = -19.735 uV 13:23:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 439.184 uVs 13:23:24 Integrated Voltage Measurement... 13:23:33 Voltage Offset Correction: v_off_ini = -27.274 uV, v_off_fin = -20.567 uV 13:23:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.662 uVs 13:23:33 Integrated Voltage Measurement... 13:23:42 Voltage Offset Correction: v_off_ini = -7.091 uV, v_off_fin = -6.485 uV 13:23:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.501 uVs 13:23:42 Integrated Voltage Measurement... 13:23:51 Voltage Offset Correction: v_off_ini = -12.685 uV, v_off_fin = -18.411 uV 13:23:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -452.241 uVs 13:23:51 Integrated Voltage Measurement... 13:24:00 Voltage Offset Correction: v_off_ini = -17.320 uV, v_off_fin = -17.931 uV 13:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 462.363 uVs 13:24:03 I2Y Average and RMS of Measurements VT = -454.793 +- 1.968 uVs I2Y = -41.842 +- 0.180 uTm^2 13:24:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:24:24 Integrated Voltage Measurement... 13:24:33 Voltage Offset Correction: v_off_ini = -11.256 uV, v_off_fin = -20.531 uV 13:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.972 uVs 13:24:33 Integrated Voltage Measurement... 13:24:42 Voltage Offset Correction: v_off_ini = -9.422 uV, v_off_fin = -14.677 uV 13:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.618 uVs 13:24:42 Integrated Voltage Measurement... 13:24:51 Voltage Offset Correction: v_off_ini = 0.176 uV, v_off_fin = -13.794 uV 13:24:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.043 uVs 13:24:51 Integrated Voltage Measurement... 13:25:00 Voltage Offset Correction: v_off_ini = -0.495 uV, v_off_fin = 12.537 uV 13:25:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.417 uVs 13:25:00 Integrated Voltage Measurement... 13:25:09 Voltage Offset Correction: v_off_ini = 6.208 uV, v_off_fin = -3.621 uV 13:25:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.396 uVs 13:25:09 Integrated Voltage Measurement... 13:25:18 Voltage Offset Correction: v_off_ini = -4.842 uV, v_off_fin = -5.159 uV 13:25:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.259 uVs 13:25:22 I1X Average and RMS of Measurements VT = -83.618 +- 5.072 uVs I1X = 16.724 +- 1.015 uTm 13:25:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:25:29 Integrated Voltage Measurement... 13:25:38 Voltage Offset Correction: v_off_ini = -11.580 uV, v_off_fin = -11.215 uV 13:25:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.103 uVs 13:25:38 Integrated Voltage Measurement... 13:25:47 Voltage Offset Correction: v_off_ini = -7.279 uV, v_off_fin = 8.369 uV 13:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.887 uVs 13:25:47 Integrated Voltage Measurement... 13:25:56 Voltage Offset Correction: v_off_ini = -7.206 uV, v_off_fin = -14.309 uV 13:25:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.586 uVs 13:25:56 Integrated Voltage Measurement... 13:26:05 Voltage Offset Correction: v_off_ini = -20.990 uV, v_off_fin = -2.175 uV 13:26:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.479 uVs 13:26:05 Integrated Voltage Measurement... 13:26:14 Voltage Offset Correction: v_off_ini = -8.741 uV, v_off_fin = -28.210 uV 13:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.594 uVs 13:26:14 Integrated Voltage Measurement... 13:26:23 Voltage Offset Correction: v_off_ini = -9.831 uV, v_off_fin = 7.789 uV 13:26:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.272 uVs 13:26:27 I1Y Average and RMS of Measurements VT = -212.320 +- 2.078 uVs I1Y = -42.464 +- 0.416 uTm 13:26:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:26:35 Integrated Voltage Measurement... 13:26:44 Voltage Offset Correction: v_off_ini = 8.830 uV, v_off_fin = 8.574 uV 13:26:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.115 uVs 13:26:44 Integrated Voltage Measurement... 13:26:53 Voltage Offset Correction: v_off_ini = -4.998 uV, v_off_fin = 6.195 uV 13:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.731 uVs 13:26:53 Integrated Voltage Measurement... 13:27:02 Voltage Offset Correction: v_off_ini = 21.599 uV, v_off_fin = 11.260 uV 13:27:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.980 uVs 13:27:02 Integrated Voltage Measurement... 13:27:11 Voltage Offset Correction: v_off_ini = 7.229 uV, v_off_fin = 0.162 uV 13:27:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.241 uVs 13:27:11 Integrated Voltage Measurement... 13:27:20 Voltage Offset Correction: v_off_ini = 1.720 uV, v_off_fin = -4.692 uV 13:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.173 uVs 13:27:20 Integrated Voltage Measurement... 13:27:29 Voltage Offset Correction: v_off_ini = 14.195 uV, v_off_fin = 18.761 uV 13:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.401 uVs 13:27:31 I2X Average and RMS of Measurements VT = -76.773 +- 2.852 uVs I2X = 7.063 +- 0.262 uTm^2 13:27:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:27:39 Integrated Voltage Measurement... 13:27:48 Voltage Offset Correction: v_off_ini = 10.704 uV, v_off_fin = 9.423 uV 13:27:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.891 uVs 13:27:48 Integrated Voltage Measurement... 13:27:57 Voltage Offset Correction: v_off_ini = 11.216 uV, v_off_fin = 7.599 uV 13:27:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.008 uVs 13:27:57 Integrated Voltage Measurement... 13:28:06 Voltage Offset Correction: v_off_ini = -6.173 uV, v_off_fin = -3.656 uV 13:28:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.850 uVs 13:28:06 Integrated Voltage Measurement... 13:28:15 Voltage Offset Correction: v_off_ini = -6.510 uV, v_off_fin = -3.652 uV 13:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.842 uVs 13:28:15 Integrated Voltage Measurement... 13:28:24 Voltage Offset Correction: v_off_ini = -7.000 uV, v_off_fin = -14.568 uV 13:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -432.997 uVs 13:28:24 Integrated Voltage Measurement... 13:28:33 Voltage Offset Correction: v_off_ini = -14.072 uV, v_off_fin = -9.370 uV 13:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 447.488 uVs 13:28:36 I2Y Average and RMS of Measurements VT = -437.513 +- 2.164 uVs I2Y = -40.251 +- 0.199 uTm^2 13:28:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:28:45 Integrated Voltage Measurement... 13:28:54 Voltage Offset Correction: v_off_ini = -9.534 uV, v_off_fin = 0.463 uV 13:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.508 uVs 13:28:54 Integrated Voltage Measurement... 13:29:03 Voltage Offset Correction: v_off_ini = 4.976 uV, v_off_fin = -0.647 uV 13:29:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.950 uVs 13:29:03 Integrated Voltage Measurement... 13:29:12 Voltage Offset Correction: v_off_ini = 3.342 uV, v_off_fin = -17.018 uV 13:29:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.780 uVs 13:29:12 Integrated Voltage Measurement... 13:29:21 Voltage Offset Correction: v_off_ini = -3.322 uV, v_off_fin = -4.142 uV 13:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.821 uVs 13:29:21 Integrated Voltage Measurement... 13:29:30 Voltage Offset Correction: v_off_ini = -5.919 uV, v_off_fin = -23.873 uV 13:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.016 uVs 13:29:30 Integrated Voltage Measurement... 13:29:39 Voltage Offset Correction: v_off_ini = -10.637 uV, v_off_fin = 6.576 uV 13:29:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.693 uVs 13:29:43 I1X Average and RMS of Measurements VT = -97.295 +- 3.393 uVs I1X = 19.459 +- 0.679 uTm 13:29:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:29:50 Integrated Voltage Measurement... 13:29:59 Voltage Offset Correction: v_off_ini = 24.701 uV, v_off_fin = 0.275 uV 13:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.895 uVs 13:29:59 Integrated Voltage Measurement... 13:30:08 Voltage Offset Correction: v_off_ini = 2.898 uV, v_off_fin = 17.402 uV 13:30:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.586 uVs 13:30:08 Integrated Voltage Measurement... 13:30:17 Voltage Offset Correction: v_off_ini = 14.819 uV, v_off_fin = 4.294 uV 13:30:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.096 uVs 13:30:17 Integrated Voltage Measurement... 13:30:26 Voltage Offset Correction: v_off_ini = 17.043 uV, v_off_fin = 23.284 uV 13:30:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.330 uVs 13:30:26 Integrated Voltage Measurement... 13:30:35 Voltage Offset Correction: v_off_ini = 15.248 uV, v_off_fin = 7.422 uV 13:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.996 uVs 13:30:35 Integrated Voltage Measurement... 13:30:44 Voltage Offset Correction: v_off_ini = 31.829 uV, v_off_fin = 31.266 uV 13:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.966 uVs 13:30:48 I1Y Average and RMS of Measurements VT = -212.812 +- 7.282 uVs I1Y = -42.562 +- 1.456 uTm 13:30:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:30:56 Integrated Voltage Measurement... 13:31:05 Voltage Offset Correction: v_off_ini = 43.267 uV, v_off_fin = 36.683 uV 13:31:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.114 uVs 13:31:05 Integrated Voltage Measurement... 13:31:14 Voltage Offset Correction: v_off_ini = 34.464 uV, v_off_fin = 43.403 uV 13:31:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.772 uVs 13:31:14 Integrated Voltage Measurement... 13:31:23 Voltage Offset Correction: v_off_ini = 22.311 uV, v_off_fin = 13.434 uV 13:31:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.924 uVs 13:31:23 Integrated Voltage Measurement... 13:31:32 Voltage Offset Correction: v_off_ini = 23.813 uV, v_off_fin = 37.689 uV 13:31:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.075 uVs 13:31:32 Integrated Voltage Measurement... 13:31:41 Voltage Offset Correction: v_off_ini = 33.582 uV, v_off_fin = 27.712 uV 13:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.698 uVs 13:31:41 Integrated Voltage Measurement... 13:31:50 Voltage Offset Correction: v_off_ini = 37.367 uV, v_off_fin = 48.433 uV 13:31:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.690 uVs 13:31:52 I2X Average and RMS of Measurements VT = -86.046 +- 8.165 uVs I2X = 7.916 +- 0.751 uTm^2 13:31:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:32:00 Integrated Voltage Measurement... 13:32:09 Voltage Offset Correction: v_off_ini = 37.462 uV, v_off_fin = 35.081 uV 13:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.264 uVs 13:32:09 Integrated Voltage Measurement... 13:32:18 Voltage Offset Correction: v_off_ini = 28.344 uV, v_off_fin = 26.924 uV 13:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.867 uVs 13:32:18 Integrated Voltage Measurement... 13:32:27 Voltage Offset Correction: v_off_ini = 36.657 uV, v_off_fin = 41.285 uV 13:32:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.160 uVs 13:32:27 Integrated Voltage Measurement... 13:32:36 Voltage Offset Correction: v_off_ini = 69.013 uV, v_off_fin = 66.603 uV 13:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 429.989 uVs 13:32:36 Integrated Voltage Measurement... 13:32:45 Voltage Offset Correction: v_off_ini = 53.702 uV, v_off_fin = 51.352 uV 13:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -438.147 uVs 13:32:45 Integrated Voltage Measurement... 13:32:54 Voltage Offset Correction: v_off_ini = 41.580 uV, v_off_fin = 40.205 uV 13:32:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.740 uVs 13:32:57 I2Y Average and RMS of Measurements VT = -438.028 +- 10.266 uVs I2Y = -40.299 +- 0.944 uTm^2 13:33:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:05 Integrated Voltage Measurement... 13:33:14 Voltage Offset Correction: v_off_ini = 40.888 uV, v_off_fin = 32.883 uV 13:33:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.073 uVs 13:33:14 Integrated Voltage Measurement... 13:33:23 Voltage Offset Correction: v_off_ini = 40.884 uV, v_off_fin = 42.314 uV 13:33:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.298 uVs 13:33:24 Integrated Voltage Measurement... 13:33:32 Voltage Offset Correction: v_off_ini = 33.225 uV, v_off_fin = 29.087 uV 13:33:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.657 uVs 13:33:33 Integrated Voltage Measurement... 13:33:42 Voltage Offset Correction: v_off_ini = 44.860 uV, v_off_fin = 32.408 uV 13:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.649 uVs 13:33:42 Integrated Voltage Measurement... 13:33:51 Voltage Offset Correction: v_off_ini = 27.072 uV, v_off_fin = 24.039 uV 13:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.152 uVs 13:33:51 Integrated Voltage Measurement... 13:34:00 Voltage Offset Correction: v_off_ini = 33.661 uV, v_off_fin = 48.104 uV 13:34:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.577 uVs 13:34:04 I1X Average and RMS of Measurements VT = -102.568 +- 2.748 uVs I1X = 20.514 +- 0.550 uTm 13:34:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:11 Integrated Voltage Measurement... 13:34:20 Voltage Offset Correction: v_off_ini = 42.207 uV, v_off_fin = 30.169 uV 13:34:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -188.752 uVs 13:34:20 Integrated Voltage Measurement... 13:34:29 Voltage Offset Correction: v_off_ini = 41.930 uV, v_off_fin = 58.507 uV 13:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.425 uVs 13:34:29 Integrated Voltage Measurement... 13:34:38 Voltage Offset Correction: v_off_ini = 56.382 uV, v_off_fin = 47.625 uV 13:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.237 uVs 13:34:38 Integrated Voltage Measurement... 13:34:47 Voltage Offset Correction: v_off_ini = 53.433 uV, v_off_fin = 63.884 uV 13:34:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.199 uVs 13:34:47 Integrated Voltage Measurement... 13:34:56 Voltage Offset Correction: v_off_ini = 49.288 uV, v_off_fin = 46.767 uV 13:34:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.522 uVs 13:34:56 Integrated Voltage Measurement... 13:35:05 Voltage Offset Correction: v_off_ini = 48.172 uV, v_off_fin = 57.712 uV 13:35:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.440 uVs 13:35:09 I1Y Average and RMS of Measurements VT = -196.096 +- 3.640 uVs I1Y = -39.220 +- 0.727 uTm 13:35:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:17 Integrated Voltage Measurement... 13:35:26 Voltage Offset Correction: v_off_ini = 52.606 uV, v_off_fin = 44.774 uV 13:35:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.224 uVs 13:35:26 Integrated Voltage Measurement... 13:35:35 Voltage Offset Correction: v_off_ini = 40.695 uV, v_off_fin = 69.361 uV 13:35:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.162 uVs 13:35:35 Integrated Voltage Measurement... 13:35:44 Voltage Offset Correction: v_off_ini = 43.019 uV, v_off_fin = 35.824 uV 13:35:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.555 uVs 13:35:44 Integrated Voltage Measurement... 13:35:53 Voltage Offset Correction: v_off_ini = 36.103 uV, v_off_fin = 57.915 uV 13:35:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.276 uVs 13:35:53 Integrated Voltage Measurement... 13:36:02 Voltage Offset Correction: v_off_ini = 38.959 uV, v_off_fin = 46.399 uV 13:36:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.500 uVs 13:36:02 Integrated Voltage Measurement... 13:36:11 Voltage Offset Correction: v_off_ini = 55.296 uV, v_off_fin = 63.981 uV 13:36:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.366 uVs 13:36:13 I2X Average and RMS of Measurements VT = -111.014 +- 6.594 uVs I2X = 10.213 +- 0.607 uTm^2 13:36:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:21 Integrated Voltage Measurement... 13:36:30 Voltage Offset Correction: v_off_ini = 50.294 uV, v_off_fin = 59.031 uV 13:36:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -411.172 uVs 13:36:30 Integrated Voltage Measurement... 13:36:39 Voltage Offset Correction: v_off_ini = 59.255 uV, v_off_fin = 57.874 uV 13:36:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 425.993 uVs 13:36:39 Integrated Voltage Measurement... 13:36:48 Voltage Offset Correction: v_off_ini = 49.343 uV, v_off_fin = 50.181 uV 13:36:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -418.088 uVs 13:36:48 Integrated Voltage Measurement... 13:36:57 Voltage Offset Correction: v_off_ini = 37.273 uV, v_off_fin = 34.232 uV 13:36:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 420.759 uVs 13:36:57 Integrated Voltage Measurement... 13:37:06 Voltage Offset Correction: v_off_ini = 28.781 uV, v_off_fin = 38.986 uV 13:37:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.108 uVs 13:37:06 Integrated Voltage Measurement... 13:37:15 Voltage Offset Correction: v_off_ini = 47.737 uV, v_off_fin = 47.747 uV 13:37:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 422.659 uVs 13:37:18 I2Y Average and RMS of Measurements VT = -421.130 +- 3.027 uVs I2Y = -38.744 +- 0.279 uTm^2 13:37:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:37:26 Integrated Voltage Measurement... 13:37:35 Voltage Offset Correction: v_off_ini = 37.876 uV, v_off_fin = 51.982 uV 13:37:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.635 uVs 13:37:36 Integrated Voltage Measurement... 13:37:44 Voltage Offset Correction: v_off_ini = 52.168 uV, v_off_fin = 51.257 uV 13:37:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.403 uVs 13:37:45 Integrated Voltage Measurement... 13:37:54 Voltage Offset Correction: v_off_ini = 44.919 uV, v_off_fin = 44.276 uV 13:37:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.314 uVs 13:37:54 Integrated Voltage Measurement... 13:38:03 Voltage Offset Correction: v_off_ini = 64.300 uV, v_off_fin = 50.364 uV 13:38:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.988 uVs 13:38:03 Integrated Voltage Measurement... 13:38:12 Voltage Offset Correction: v_off_ini = 50.558 uV, v_off_fin = 61.939 uV 13:38:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.777 uVs 13:38:12 Integrated Voltage Measurement... 13:38:21 Voltage Offset Correction: v_off_ini = 64.443 uV, v_off_fin = 57.117 uV 13:38:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.361 uVs 13:38:25 I1X Average and RMS of Measurements VT = -107.413 +- 13.627 uVs I1X = 21.483 +- 2.725 uTm 13:38:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:38:32 Integrated Voltage Measurement... 13:38:41 Voltage Offset Correction: v_off_ini = 60.770 uV, v_off_fin = 58.087 uV 13:38:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -196.201 uVs 13:38:41 Integrated Voltage Measurement... 13:38:50 Voltage Offset Correction: v_off_ini = 65.077 uV, v_off_fin = 75.995 uV 13:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.671 uVs 13:38:50 Integrated Voltage Measurement... 13:38:59 Voltage Offset Correction: v_off_ini = 60.650 uV, v_off_fin = 41.191 uV 13:38:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.003 uVs 13:38:59 Integrated Voltage Measurement... 13:39:08 Voltage Offset Correction: v_off_ini = 60.085 uV, v_off_fin = 58.730 uV 13:39:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.769 uVs 13:39:08 Integrated Voltage Measurement... 13:39:17 Voltage Offset Correction: v_off_ini = 52.033 uV, v_off_fin = 42.133 uV 13:39:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.995 uVs 13:39:17 Integrated Voltage Measurement... 13:39:26 Voltage Offset Correction: v_off_ini = 53.121 uV, v_off_fin = 69.930 uV 13:39:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.435 uVs 13:39:30 I1Y Average and RMS of Measurements VT = -198.513 +- 4.065 uVs I1Y = -39.703 +- 0.812 uTm 13:39:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:39:38 Integrated Voltage Measurement... 13:39:47 Voltage Offset Correction: v_off_ini = 65.384 uV, v_off_fin = 57.550 uV 13:39:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.198 uVs 13:39:47 Integrated Voltage Measurement... 13:39:56 Voltage Offset Correction: v_off_ini = 70.457 uV, v_off_fin = 70.659 uV 13:39:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.669 uVs 13:39:56 Integrated Voltage Measurement... 13:40:05 Voltage Offset Correction: v_off_ini = 60.974 uV, v_off_fin = 51.823 uV 13:40:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.101 uVs 13:40:05 Integrated Voltage Measurement... 13:40:14 Voltage Offset Correction: v_off_ini = 67.349 uV, v_off_fin = 66.687 uV 13:40:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.158 uVs 13:40:14 Integrated Voltage Measurement... 13:40:23 Voltage Offset Correction: v_off_ini = 64.294 uV, v_off_fin = 46.660 uV 13:40:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.400 uVs 13:40:23 Integrated Voltage Measurement... 13:40:32 Voltage Offset Correction: v_off_ini = 56.581 uV, v_off_fin = 71.399 uV 13:40:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.480 uVs 13:40:34 I2X Average and RMS of Measurements VT = -120.001 +- 2.998 uVs I2X = 11.040 +- 0.276 uTm^2 13:40:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:40:42 Integrated Voltage Measurement... 13:40:51 Voltage Offset Correction: v_off_ini = 37.521 uV, v_off_fin = 45.552 uV 13:40:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.870 uVs 13:40:51 Integrated Voltage Measurement... 13:41:00 Voltage Offset Correction: v_off_ini = 41.815 uV, v_off_fin = 47.517 uV 13:41:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 424.706 uVs 13:41:00 Integrated Voltage Measurement... 13:41:09 Voltage Offset Correction: v_off_ini = 34.432 uV, v_off_fin = 52.136 uV 13:41:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.447 uVs 13:41:09 Integrated Voltage Measurement... 13:41:18 Voltage Offset Correction: v_off_ini = 37.473 uV, v_off_fin = 44.955 uV 13:41:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.385 uVs 13:41:18 Integrated Voltage Measurement... 13:41:27 Voltage Offset Correction: v_off_ini = 48.425 uV, v_off_fin = 48.571 uV 13:41:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.553 uVs 13:41:27 Integrated Voltage Measurement... 13:41:36 Voltage Offset Correction: v_off_ini = 41.207 uV, v_off_fin = 49.099 uV 13:41:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.339 uVs 13:41:38 I2Y Average and RMS of Measurements VT = -433.717 +- 7.618 uVs I2Y = -39.902 +- 0.701 uTm^2 13:41:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:41:47 Integrated Voltage Measurement... 13:41:56 Voltage Offset Correction: v_off_ini = 44.046 uV, v_off_fin = 39.604 uV 13:41:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.041 uVs 13:41:56 Integrated Voltage Measurement... 13:42:05 Voltage Offset Correction: v_off_ini = 42.012 uV, v_off_fin = 47.215 uV 13:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.596 uVs 13:42:05 Integrated Voltage Measurement... 13:42:14 Voltage Offset Correction: v_off_ini = 58.491 uV, v_off_fin = 51.254 uV 13:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.976 uVs 13:42:14 Integrated Voltage Measurement... 13:42:23 Voltage Offset Correction: v_off_ini = 55.161 uV, v_off_fin = 58.730 uV 13:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.352 uVs 13:42:23 Integrated Voltage Measurement... 13:42:32 Voltage Offset Correction: v_off_ini = 62.183 uV, v_off_fin = 49.526 uV 13:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.781 uVs 13:42:32 Integrated Voltage Measurement... 13:42:41 Voltage Offset Correction: v_off_ini = 52.390 uV, v_off_fin = 60.317 uV 13:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.488 uVs 13:42:45 I1X Average and RMS of Measurements VT = -123.039 +- 10.408 uVs I1X = 24.608 +- 2.081 uTm 13:42:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:42:52 Integrated Voltage Measurement... 13:43:01 Voltage Offset Correction: v_off_ini = 45.029 uV, v_off_fin = 35.045 uV 13:43:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.160 uVs 13:43:01 Integrated Voltage Measurement... 13:43:10 Voltage Offset Correction: v_off_ini = 42.312 uV, v_off_fin = 48.422 uV 13:43:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.748 uVs 13:43:10 Integrated Voltage Measurement... 13:43:19 Voltage Offset Correction: v_off_ini = 29.629 uV, v_off_fin = 22.757 uV 13:43:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -174.058 uVs 13:43:19 Integrated Voltage Measurement... 13:43:28 Voltage Offset Correction: v_off_ini = 36.327 uV, v_off_fin = 50.685 uV 13:43:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.992 uVs 13:43:28 Integrated Voltage Measurement... 13:43:37 Voltage Offset Correction: v_off_ini = 45.110 uV, v_off_fin = 34.431 uV 13:43:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.129 uVs 13:43:37 Integrated Voltage Measurement... 13:43:46 Voltage Offset Correction: v_off_ini = 41.660 uV, v_off_fin = 55.259 uV 13:43:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.118 uVs 13:43:50 I1Y Average and RMS of Measurements VT = -181.534 +- 2.206 uVs I1Y = -36.307 +- 0.441 uTm 13:43:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:43:58 Integrated Voltage Measurement... 13:44:07 Voltage Offset Correction: v_off_ini = 44.351 uV, v_off_fin = 44.619 uV 13:44:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.282 uVs 13:44:07 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = 42.284 uV, v_off_fin = 67.524 uV 13:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.388 uVs 13:44:16 Integrated Voltage Measurement... 13:44:25 Voltage Offset Correction: v_off_ini = 48.509 uV, v_off_fin = 47.171 uV 13:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.741 uVs 13:44:25 Integrated Voltage Measurement... 13:44:34 Voltage Offset Correction: v_off_ini = 56.673 uV, v_off_fin = 64.078 uV 13:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.697 uVs 13:44:34 Integrated Voltage Measurement... 13:44:43 Voltage Offset Correction: v_off_ini = 58.001 uV, v_off_fin = 55.800 uV 13:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.819 uVs 13:44:43 Integrated Voltage Measurement... 13:44:52 Voltage Offset Correction: v_off_ini = 59.129 uV, v_off_fin = 65.848 uV 13:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.112 uVs 13:44:55 I2X Average and RMS of Measurements VT = -128.340 +- 7.744 uVs I2X = 11.807 +- 0.712 uTm^2 13:45:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:45:02 Integrated Voltage Measurement... 13:45:11 Voltage Offset Correction: v_off_ini = 50.243 uV, v_off_fin = 57.978 uV 13:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -403.821 uVs 13:45:11 Integrated Voltage Measurement... 13:45:20 Voltage Offset Correction: v_off_ini = 75.746 uV, v_off_fin = 56.824 uV 13:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.170 uVs 13:45:20 Integrated Voltage Measurement... 13:45:29 Voltage Offset Correction: v_off_ini = 53.302 uV, v_off_fin = 51.594 uV 13:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.667 uVs 13:45:29 Integrated Voltage Measurement... 13:45:38 Voltage Offset Correction: v_off_ini = 57.833 uV, v_off_fin = 55.909 uV 13:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 403.006 uVs 13:45:38 Integrated Voltage Measurement... 13:45:47 Voltage Offset Correction: v_off_ini = 61.742 uV, v_off_fin = 56.939 uV 13:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -416.436 uVs 13:45:47 Integrated Voltage Measurement... 13:45:56 Voltage Offset Correction: v_off_ini = 61.705 uV, v_off_fin = 59.842 uV 13:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.038 uVs 13:45:59 I2Y Average and RMS of Measurements VT = -406.690 +- 2.966 uVs I2Y = -37.415 +- 0.273 uTm^2 13:46:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:46:11 Integrated Voltage Measurement... 13:46:20 Voltage Offset Correction: v_off_ini = 72.470 uV, v_off_fin = 61.016 uV 13:46:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.531 uVs 13:46:20 Integrated Voltage Measurement... 13:46:29 Voltage Offset Correction: v_off_ini = 76.899 uV, v_off_fin = 75.046 uV 13:46:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.294 uVs 13:46:29 Integrated Voltage Measurement... 13:46:38 Voltage Offset Correction: v_off_ini = 79.706 uV, v_off_fin = 71.107 uV 13:46:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.101 uVs 13:46:38 Integrated Voltage Measurement... 13:46:47 Voltage Offset Correction: v_off_ini = 82.814 uV, v_off_fin = 95.563 uV 13:46:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.646 uVs 13:46:47 Integrated Voltage Measurement... 13:46:56 Voltage Offset Correction: v_off_ini = 82.219 uV, v_off_fin = 72.381 uV 13:46:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -95.372 uVs 13:46:56 Integrated Voltage Measurement... 13:47:05 Voltage Offset Correction: v_off_ini = 86.422 uV, v_off_fin = 84.285 uV 13:47:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 63.914 uVs 13:47:09 I1X Average and RMS of Measurements VT = -87.643 +- 6.628 uVs I1X = 17.531 +- 1.325 uTm 13:47:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:47:16 Integrated Voltage Measurement... 13:47:25 Voltage Offset Correction: v_off_ini = 100.286 uV, v_off_fin = 79.712 uV 13:47:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.440 uVs 13:47:25 Integrated Voltage Measurement... 13:47:34 Voltage Offset Correction: v_off_ini = 63.109 uV, v_off_fin = 72.429 uV 13:47:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.808 uVs 13:47:34 Integrated Voltage Measurement... 13:47:43 Voltage Offset Correction: v_off_ini = 74.627 uV, v_off_fin = 59.929 uV 13:47:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.244 uVs 13:47:43 Integrated Voltage Measurement... 13:47:52 Voltage Offset Correction: v_off_ini = 67.835 uV, v_off_fin = 81.002 uV 13:47:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.195 uVs 13:47:52 Integrated Voltage Measurement... 13:48:01 Voltage Offset Correction: v_off_ini = 82.373 uV, v_off_fin = 70.400 uV 13:48:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.388 uVs 13:48:01 Integrated Voltage Measurement... 13:48:10 Voltage Offset Correction: v_off_ini = 67.146 uV, v_off_fin = 89.258 uV 13:48:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.367 uVs 13:48:14 I1Y Average and RMS of Measurements VT = -192.740 +- 2.884 uVs I1Y = -38.548 +- 0.577 uTm 13:48:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:48:19 Integrated Voltage Measurement... 13:48:28 Voltage Offset Correction: v_off_ini = 86.240 uV, v_off_fin = 69.747 uV 13:48:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.721 uVs 13:48:28 Integrated Voltage Measurement... 13:48:37 Voltage Offset Correction: v_off_ini = 63.888 uV, v_off_fin = 80.788 uV 13:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.611 uVs 13:48:37 Integrated Voltage Measurement... 13:48:46 Voltage Offset Correction: v_off_ini = 81.793 uV, v_off_fin = 70.235 uV 13:48:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.760 uVs 13:48:46 Integrated Voltage Measurement... 13:48:55 Voltage Offset Correction: v_off_ini = 81.750 uV, v_off_fin = 89.884 uV 13:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.879 uVs 13:48:55 Integrated Voltage Measurement... 13:49:04 Voltage Offset Correction: v_off_ini = 72.215 uV, v_off_fin = 72.477 uV 13:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.846 uVs 13:49:04 Integrated Voltage Measurement... 13:49:13 Voltage Offset Correction: v_off_ini = 97.105 uV, v_off_fin = 95.606 uV 13:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.581 uVs 13:49:15 I2X Average and RMS of Measurements VT = -88.400 +- 8.264 uVs I2X = 8.133 +- 0.760 uTm^2 13:49:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:49:21 Integrated Voltage Measurement... 13:49:30 Voltage Offset Correction: v_off_ini = 79.021 uV, v_off_fin = 78.965 uV 13:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.108 uVs 13:49:30 Integrated Voltage Measurement... 13:49:39 Voltage Offset Correction: v_off_ini = 93.708 uV, v_off_fin = 97.099 uV 13:49:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 418.021 uVs 13:49:39 Integrated Voltage Measurement... 13:49:48 Voltage Offset Correction: v_off_ini = 102.393 uV, v_off_fin = 93.828 uV 13:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.489 uVs 13:49:48 Integrated Voltage Measurement... 13:49:57 Voltage Offset Correction: v_off_ini = 103.347 uV, v_off_fin = 88.328 uV 13:49:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.115 uVs 13:49:57 Integrated Voltage Measurement... 13:50:06 Voltage Offset Correction: v_off_ini = 72.220 uV, v_off_fin = 79.132 uV 13:50:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -410.111 uVs 13:50:06 Integrated Voltage Measurement... 13:50:15 Voltage Offset Correction: v_off_ini = 78.060 uV, v_off_fin = 84.429 uV 13:50:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 427.524 uVs 13:50:17 I2Y Average and RMS of Measurements VT = -409.895 +- 6.330 uVs I2Y = -37.711 +- 0.582 uTm^2 13:50:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:50:25 Integrated Voltage Measurement... 13:50:34 Voltage Offset Correction: v_off_ini = 88.389 uV, v_off_fin = 79.314 uV 13:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.337 uVs 13:50:34 Integrated Voltage Measurement... 13:50:43 Voltage Offset Correction: v_off_ini = 89.248 uV, v_off_fin = 85.624 uV 13:50:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.615 uVs 13:50:43 Integrated Voltage Measurement... 13:50:52 Voltage Offset Correction: v_off_ini = 81.627 uV, v_off_fin = 74.025 uV 13:50:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.494 uVs 13:50:52 Integrated Voltage Measurement... 13:51:01 Voltage Offset Correction: v_off_ini = 79.020 uV, v_off_fin = 79.902 uV 13:51:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.278 uVs 13:51:01 Integrated Voltage Measurement... 13:51:10 Voltage Offset Correction: v_off_ini = 77.017 uV, v_off_fin = 69.594 uV 13:51:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.220 uVs 13:51:10 Integrated Voltage Measurement... 13:51:19 Voltage Offset Correction: v_off_ini = 59.868 uV, v_off_fin = 59.484 uV 13:51:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.189 uVs 13:51:24 I1X Average and RMS of Measurements VT = -87.189 +- 6.370 uVs I1X = 17.438 +- 1.274 uTm 13:51:26 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:51:30 Integrated Voltage Measurement... 13:51:39 Voltage Offset Correction: v_off_ini = 72.715 uV, v_off_fin = 61.367 uV 13:51:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -202.679 uVs 13:51:39 Integrated Voltage Measurement... 13:51:48 Voltage Offset Correction: v_off_ini = 69.320 uV, v_off_fin = 69.114 uV 13:51:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.324 uVs 13:51:48 Integrated Voltage Measurement... 13:51:57 Voltage Offset Correction: v_off_ini = 51.649 uV, v_off_fin = 40.267 uV 13:51:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.781 uVs 13:51:57 Integrated Voltage Measurement... 13:52:06 Voltage Offset Correction: v_off_ini = 57.803 uV, v_off_fin = 67.107 uV 13:52:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.513 uVs 13:52:06 Integrated Voltage Measurement... 13:52:15 Voltage Offset Correction: v_off_ini = 58.581 uV, v_off_fin = 54.463 uV 13:52:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.183 uVs 13:52:15 Integrated Voltage Measurement... 13:52:24 Voltage Offset Correction: v_off_ini = 63.598 uV, v_off_fin = 72.007 uV 13:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.300 uVs 13:52:29 I1Y Average and RMS of Measurements VT = -191.463 +- 4.273 uVs I1Y = -38.294 +- 0.856 uTm 13:52:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:52:34 Integrated Voltage Measurement... 13:52:43 Voltage Offset Correction: v_off_ini = 67.579 uV, v_off_fin = 60.380 uV 13:52:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.026 uVs 13:52:43 Integrated Voltage Measurement... 13:52:52 Voltage Offset Correction: v_off_ini = 83.234 uV, v_off_fin = 85.510 uV 13:52:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.968 uVs 13:52:52 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = 92.355 uV, v_off_fin = 61.531 uV 13:53:01 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -84.413 uVs 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = 79.110 uV, v_off_fin = 82.354 uV 13:53:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.437 uVs 13:53:10 Integrated Voltage Measurement... 13:53:19 Voltage Offset Correction: v_off_ini = 70.100 uV, v_off_fin = 53.447 uV 13:53:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.362 uVs 13:53:19 Integrated Voltage Measurement... 13:53:28 Voltage Offset Correction: v_off_ini = 73.762 uV, v_off_fin = 75.000 uV 13:53:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.410 uVs 13:53:30 I2X Average and RMS of Measurements VT = -89.103 +- 2.760 uVs I2X = 8.198 +- 0.254 uTm^2 13:53:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:53:35 Integrated Voltage Measurement... 13:53:44 Voltage Offset Correction: v_off_ini = 70.523 uV, v_off_fin = 75.981 uV 13:53:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.720 uVs 13:53:44 Integrated Voltage Measurement... 13:53:53 Voltage Offset Correction: v_off_ini = 93.918 uV, v_off_fin = 83.032 uV 13:53:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 415.993 uVs 13:53:54 Integrated Voltage Measurement... 13:54:03 Voltage Offset Correction: v_off_ini = 79.346 uV, v_off_fin = 97.189 uV 13:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.669 uVs 13:54:03 Integrated Voltage Measurement... 13:54:12 Voltage Offset Correction: v_off_ini = 93.655 uV, v_off_fin = 101.090 uV 13:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.300 uVs 13:54:12 Integrated Voltage Measurement... 13:54:21 Voltage Offset Correction: v_off_ini = 103.139 uV, v_off_fin = 95.466 uV 13:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.347 uVs 13:54:21 Integrated Voltage Measurement... 13:54:30 Voltage Offset Correction: v_off_ini = 96.935 uV, v_off_fin = 101.811 uV 13:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 406.921 uVs 13:54:32 I2Y Average and RMS of Measurements VT = -417.992 +- 2.137 uVs I2Y = -38.456 +- 0.196 uTm^2 13:54:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:40 Integrated Voltage Measurement... 13:54:49 Voltage Offset Correction: v_off_ini = 96.175 uV, v_off_fin = 84.256 uV 13:54:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.783 uVs 13:54:49 Integrated Voltage Measurement... 13:54:58 Voltage Offset Correction: v_off_ini = 86.409 uV, v_off_fin = 87.180 uV 13:54:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.923 uVs 13:54:58 Integrated Voltage Measurement... 13:55:07 Voltage Offset Correction: v_off_ini = 84.101 uV, v_off_fin = 85.621 uV 13:55:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.360 uVs 13:55:07 Integrated Voltage Measurement... 13:55:16 Voltage Offset Correction: v_off_ini = 77.282 uV, v_off_fin = 87.751 uV 13:55:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.594 uVs 13:55:16 Integrated Voltage Measurement... 13:55:25 Voltage Offset Correction: v_off_ini = 68.058 uV, v_off_fin = 76.895 uV 13:55:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.106 uVs 13:55:26 Integrated Voltage Measurement... 13:55:34 Voltage Offset Correction: v_off_ini = 68.903 uV, v_off_fin = 76.832 uV 13:55:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.106 uVs 13:55:39 I1X Average and RMS of Measurements VT = -103.312 +- 7.781 uVs I1X = 20.663 +- 1.556 uTm 13:55:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:46 Integrated Voltage Measurement... 13:55:54 Voltage Offset Correction: v_off_ini = 81.171 uV, v_off_fin = 78.795 uV 13:55:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.224 uVs 13:55:55 Integrated Voltage Measurement... 13:56:03 Voltage Offset Correction: v_off_ini = 88.003 uV, v_off_fin = 91.111 uV 13:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.352 uVs 13:56:04 Integrated Voltage Measurement... 13:56:13 Voltage Offset Correction: v_off_ini = 81.953 uV, v_off_fin = 79.739 uV 13:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.528 uVs 13:56:13 Integrated Voltage Measurement... 13:56:22 Voltage Offset Correction: v_off_ini = 86.367 uV, v_off_fin = 97.355 uV 13:56:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.900 uVs 13:56:22 Integrated Voltage Measurement... 13:56:31 Voltage Offset Correction: v_off_ini = 91.087 uV, v_off_fin = 82.288 uV 13:56:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.782 uVs 13:56:31 Integrated Voltage Measurement... 13:56:40 Voltage Offset Correction: v_off_ini = 80.166 uV, v_off_fin = 92.323 uV 13:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.890 uVs 13:56:44 I1Y Average and RMS of Measurements VT = -198.946 +- 1.458 uVs I1Y = -39.789 +- 0.292 uTm 13:56:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:49 Integrated Voltage Measurement... 13:56:58 Voltage Offset Correction: v_off_ini = 79.751 uV, v_off_fin = 77.664 uV 13:56:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.203 uVs 13:56:58 Integrated Voltage Measurement... 13:57:07 Voltage Offset Correction: v_off_ini = 69.871 uV, v_off_fin = 89.219 uV 13:57:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.215 uVs 13:57:07 Integrated Voltage Measurement... 13:57:16 Voltage Offset Correction: v_off_ini = 101.552 uV, v_off_fin = 78.728 uV 13:57:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.498 uVs 13:57:16 Integrated Voltage Measurement... 13:57:25 Voltage Offset Correction: v_off_ini = 73.450 uV, v_off_fin = 89.105 uV 13:57:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.836 uVs 13:57:25 Integrated Voltage Measurement... 13:57:34 Voltage Offset Correction: v_off_ini = 72.941 uV, v_off_fin = 74.443 uV 13:57:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.294 uVs 13:57:34 Integrated Voltage Measurement... 13:57:43 Voltage Offset Correction: v_off_ini = 82.617 uV, v_off_fin = 87.381 uV 13:57:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.573 uVs 13:57:46 I2X Average and RMS of Measurements VT = -102.603 +- 3.861 uVs I2X = 9.440 +- 0.356 uTm^2 13:57:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:51 Integrated Voltage Measurement... 13:58:00 Voltage Offset Correction: v_off_ini = 91.173 uV, v_off_fin = 84.404 uV 13:58:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.114 uVs 13:58:00 Integrated Voltage Measurement... 13:58:09 Voltage Offset Correction: v_off_ini = 89.258 uV, v_off_fin = 88.069 uV 13:58:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 422.497 uVs 13:58:09 Integrated Voltage Measurement... 13:58:18 Voltage Offset Correction: v_off_ini = 90.994 uV, v_off_fin = 88.250 uV 13:58:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.263 uVs 13:58:18 Integrated Voltage Measurement... 13:58:27 Voltage Offset Correction: v_off_ini = 95.544 uV, v_off_fin = 93.202 uV 13:58:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.475 uVs 13:58:27 Integrated Voltage Measurement... 13:58:36 Voltage Offset Correction: v_off_ini = 84.010 uV, v_off_fin = 88.613 uV 13:58:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.266 uVs 13:58:36 Integrated Voltage Measurement... 13:58:45 Voltage Offset Correction: v_off_ini = 93.294 uV, v_off_fin = 84.148 uV 13:58:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 422.621 uVs 13:58:47 I2Y Average and RMS of Measurements VT = -422.373 +- 3.983 uVs I2Y = -38.858 +- 0.366 uTm^2 13:58:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:58:56 Integrated Voltage Measurement... 13:59:05 Voltage Offset Correction: v_off_ini = 89.058 uV, v_off_fin = 89.345 uV 13:59:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.743 uVs 13:59:05 Integrated Voltage Measurement... 13:59:14 Voltage Offset Correction: v_off_ini = 97.944 uV, v_off_fin = 105.309 uV 13:59:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.506 uVs 13:59:14 Integrated Voltage Measurement... 13:59:23 Voltage Offset Correction: v_off_ini = 95.688 uV, v_off_fin = 81.768 uV 13:59:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.951 uVs 13:59:23 Integrated Voltage Measurement... 13:59:32 Voltage Offset Correction: v_off_ini = 91.287 uV, v_off_fin = 93.480 uV 13:59:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.199 uVs 13:59:32 Integrated Voltage Measurement... 13:59:41 Voltage Offset Correction: v_off_ini = 90.626 uV, v_off_fin = 78.833 uV 13:59:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.907 uVs 13:59:41 Integrated Voltage Measurement... 13:59:50 Voltage Offset Correction: v_off_ini = 91.702 uV, v_off_fin = 86.847 uV 13:59:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.249 uVs 13:59:54 I1X Average and RMS of Measurements VT = -96.426 +- 1.045 uVs I1X = 19.285 +- 0.209 uTm 13:59:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:00:01 Integrated Voltage Measurement... 14:00:10 Voltage Offset Correction: v_off_ini = 99.638 uV, v_off_fin = 97.644 uV 14:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.570 uVs 14:00:10 Integrated Voltage Measurement... 14:00:19 Voltage Offset Correction: v_off_ini = 98.974 uV, v_off_fin = 109.247 uV 14:00:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.282 uVs 14:00:19 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = 105.162 uV, v_off_fin = 90.742 uV 14:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.220 uVs 14:00:28 Integrated Voltage Measurement... 14:00:37 Voltage Offset Correction: v_off_ini = 105.494 uV, v_off_fin = 110.731 uV 14:00:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.111 uVs 14:00:37 Integrated Voltage Measurement... 14:00:46 Voltage Offset Correction: v_off_ini = 88.933 uV, v_off_fin = 75.953 uV 14:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.335 uVs 14:00:46 Integrated Voltage Measurement... 14:00:55 Voltage Offset Correction: v_off_ini = 78.485 uV, v_off_fin = 99.652 uV 14:00:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.459 uVs 14:00:59 I1Y Average and RMS of Measurements VT = -206.830 +- 2.660 uVs I1Y = -41.365 +- 0.532 uTm 14:01:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:01:04 Integrated Voltage Measurement... 14:01:13 Voltage Offset Correction: v_off_ini = 83.064 uV, v_off_fin = 81.823 uV 14:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.688 uVs 14:01:13 Integrated Voltage Measurement... 14:01:22 Voltage Offset Correction: v_off_ini = 90.653 uV, v_off_fin = 87.863 uV 14:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.578 uVs 14:01:22 Integrated Voltage Measurement... 14:01:31 Voltage Offset Correction: v_off_ini = 84.759 uV, v_off_fin = 76.324 uV 14:01:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.925 uVs 14:01:31 Integrated Voltage Measurement... 14:01:40 Voltage Offset Correction: v_off_ini = 73.799 uV, v_off_fin = 76.752 uV 14:01:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.402 uVs 14:01:40 Integrated Voltage Measurement... 14:01:49 Voltage Offset Correction: v_off_ini = 73.409 uV, v_off_fin = 65.373 uV 14:01:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.867 uVs 14:01:49 Integrated Voltage Measurement... 14:01:58 Voltage Offset Correction: v_off_ini = 66.746 uV, v_off_fin = 88.670 uV 14:01:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.376 uVs 14:02:01 I2X Average and RMS of Measurements VT = -111.139 +- 9.018 uVs I2X = 10.225 +- 0.830 uTm^2 14:02:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:02:06 Integrated Voltage Measurement... 14:02:15 Voltage Offset Correction: v_off_ini = 83.696 uV, v_off_fin = 67.499 uV 14:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -429.885 uVs 14:02:15 Integrated Voltage Measurement... 14:02:24 Voltage Offset Correction: v_off_ini = 70.929 uV, v_off_fin = 71.584 uV 14:02:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.664 uVs 14:02:24 Integrated Voltage Measurement... 14:02:33 Voltage Offset Correction: v_off_ini = 79.807 uV, v_off_fin = 77.534 uV 14:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.278 uVs 14:02:33 Integrated Voltage Measurement... 14:02:42 Voltage Offset Correction: v_off_ini = 75.412 uV, v_off_fin = 82.136 uV 14:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.695 uVs 14:02:42 Integrated Voltage Measurement... 14:02:51 Voltage Offset Correction: v_off_ini = 78.934 uV, v_off_fin = 84.380 uV 14:02:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -426.102 uVs 14:02:51 Integrated Voltage Measurement... 14:03:00 Voltage Offset Correction: v_off_ini = 84.992 uV, v_off_fin = 82.609 uV 14:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 434.132 uVs 14:03:03 I2Y Average and RMS of Measurements VT = -438.126 +- 7.963 uVs I2Y = -40.308 +- 0.732 uTm^2 14:03:07 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:03:11 Integrated Voltage Measurement... 14:03:20 Voltage Offset Correction: v_off_ini = 78.666 uV, v_off_fin = 77.555 uV 14:03:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -102.736 uVs 14:03:20 Integrated Voltage Measurement... 14:03:29 Voltage Offset Correction: v_off_ini = 74.246 uV, v_off_fin = 79.386 uV 14:03:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 71.704 uVs 14:03:29 Integrated Voltage Measurement... 14:03:38 Voltage Offset Correction: v_off_ini = 68.346 uV, v_off_fin = 79.385 uV 14:03:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.468 uVs 14:03:38 Integrated Voltage Measurement... 14:03:47 Voltage Offset Correction: v_off_ini = 66.248 uV, v_off_fin = 76.945 uV 14:03:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.436 uVs 14:03:47 Integrated Voltage Measurement... 14:03:56 Voltage Offset Correction: v_off_ini = 77.740 uV, v_off_fin = 71.687 uV 14:03:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.434 uVs 14:03:56 Integrated Voltage Measurement... 14:04:05 Voltage Offset Correction: v_off_ini = 66.126 uV, v_off_fin = 80.683 uV 14:04:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 99.915 uVs 14:04:09 I1X Average and RMS of Measurements VT = -99.782 +- 9.648 uVs I1X = 19.958 +- 1.929 uTm 14:04:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:04:16 Integrated Voltage Measurement... 14:04:25 Voltage Offset Correction: v_off_ini = 75.495 uV, v_off_fin = 69.673 uV 14:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.354 uVs 14:04:25 Integrated Voltage Measurement... 14:04:34 Voltage Offset Correction: v_off_ini = 71.103 uV, v_off_fin = 77.457 uV 14:04:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.523 uVs 14:04:34 Integrated Voltage Measurement... 14:04:43 Voltage Offset Correction: v_off_ini = 75.200 uV, v_off_fin = 61.890 uV 14:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.746 uVs 14:04:43 Integrated Voltage Measurement... 14:04:52 Voltage Offset Correction: v_off_ini = 75.089 uV, v_off_fin = 101.199 uV 14:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.038 uVs 14:04:52 Integrated Voltage Measurement... 14:05:01 Voltage Offset Correction: v_off_ini = 80.472 uV, v_off_fin = 67.334 uV 14:05:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.111 uVs 14:05:01 Integrated Voltage Measurement... 14:05:10 Voltage Offset Correction: v_off_ini = 61.573 uV, v_off_fin = 84.639 uV 14:05:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.275 uVs 14:05:14 I1Y Average and RMS of Measurements VT = -203.841 +- 1.366 uVs I1Y = -40.768 +- 0.272 uTm 14:05:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:05:19 Integrated Voltage Measurement... 14:05:28 Voltage Offset Correction: v_off_ini = 75.371 uV, v_off_fin = 73.789 uV 14:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.715 uVs 14:05:28 Integrated Voltage Measurement... 14:05:37 Voltage Offset Correction: v_off_ini = 73.088 uV, v_off_fin = 72.386 uV 14:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.632 uVs 14:05:37 Integrated Voltage Measurement... 14:05:46 Voltage Offset Correction: v_off_ini = 68.940 uV, v_off_fin = 70.830 uV 14:05:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.476 uVs 14:05:47 Integrated Voltage Measurement... 14:05:55 Voltage Offset Correction: v_off_ini = 79.713 uV, v_off_fin = 92.952 uV 14:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.443 uVs 14:05:56 Integrated Voltage Measurement... 14:06:05 Voltage Offset Correction: v_off_ini = 66.284 uV, v_off_fin = 64.082 uV 14:06:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.628 uVs 14:06:05 Integrated Voltage Measurement... 14:06:14 Voltage Offset Correction: v_off_ini = 75.882 uV, v_off_fin = 72.429 uV 14:06:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.554 uVs 14:06:16 I2X Average and RMS of Measurements VT = -99.741 +- 7.141 uVs I2X = 9.176 +- 0.657 uTm^2 14:06:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:06:21 Integrated Voltage Measurement... 14:06:30 Voltage Offset Correction: v_off_ini = 58.943 uV, v_off_fin = 72.912 uV 14:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -431.692 uVs 14:06:30 Integrated Voltage Measurement... 14:06:39 Voltage Offset Correction: v_off_ini = 72.510 uV, v_off_fin = 70.603 uV 14:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.506 uVs 14:06:39 Integrated Voltage Measurement... 14:06:48 Voltage Offset Correction: v_off_ini = 55.461 uV, v_off_fin = 62.996 uV 14:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.205 uVs 14:06:48 Integrated Voltage Measurement... 14:06:57 Voltage Offset Correction: v_off_ini = 65.063 uV, v_off_fin = 74.285 uV 14:06:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.837 uVs 14:06:57 Integrated Voltage Measurement... 14:07:06 Voltage Offset Correction: v_off_ini = 75.252 uV, v_off_fin = 55.085 uV 14:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.768 uVs 14:07:06 Integrated Voltage Measurement... 14:07:15 Voltage Offset Correction: v_off_ini = 71.811 uV, v_off_fin = 68.847 uV 14:07:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 417.100 uVs 14:07:18 I2Y Average and RMS of Measurements VT = -438.518 +- 2.481 uVs I2Y = -40.344 +- 0.228 uTm^2 14:07:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:07:39 Integrated Voltage Measurement... 14:07:48 Voltage Offset Correction: v_off_ini = 74.551 uV, v_off_fin = 66.045 uV 14:07:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.734 uVs 14:07:48 Integrated Voltage Measurement... 14:07:57 Voltage Offset Correction: v_off_ini = 67.747 uV, v_off_fin = 74.570 uV 14:07:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.900 uVs 14:07:57 Integrated Voltage Measurement... 14:08:06 Voltage Offset Correction: v_off_ini = 81.438 uV, v_off_fin = 78.543 uV 14:08:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.987 uVs 14:08:06 Integrated Voltage Measurement... 14:08:15 Voltage Offset Correction: v_off_ini = 58.625 uV, v_off_fin = 56.677 uV 14:08:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.359 uVs 14:08:15 Integrated Voltage Measurement... 14:08:24 Voltage Offset Correction: v_off_ini = 74.675 uV, v_off_fin = 66.532 uV 14:08:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.119 uVs 14:08:24 Integrated Voltage Measurement... 14:08:33 Voltage Offset Correction: v_off_ini = 77.401 uV, v_off_fin = 62.131 uV 14:08:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.960 uVs 14:08:37 I1X Average and RMS of Measurements VT = -64.510 +- 8.655 uVs I1X = 12.902 +- 1.731 uTm 14:08:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:08:44 Integrated Voltage Measurement... 14:08:53 Voltage Offset Correction: v_off_ini = 71.522 uV, v_off_fin = 59.594 uV 14:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.979 uVs 14:08:53 Integrated Voltage Measurement... 14:09:02 Voltage Offset Correction: v_off_ini = 70.870 uV, v_off_fin = 70.760 uV 14:09:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 187.707 uVs 14:09:02 Integrated Voltage Measurement... 14:09:11 Voltage Offset Correction: v_off_ini = 72.580 uV, v_off_fin = 67.811 uV 14:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.573 uVs 14:09:11 Integrated Voltage Measurement... 14:09:20 Voltage Offset Correction: v_off_ini = 68.861 uV, v_off_fin = 74.946 uV 14:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.627 uVs 14:09:20 Integrated Voltage Measurement... 14:09:29 Voltage Offset Correction: v_off_ini = 64.335 uV, v_off_fin = 53.738 uV 14:09:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.175 uVs 14:09:29 Integrated Voltage Measurement... 14:09:38 Voltage Offset Correction: v_off_ini = 64.389 uV, v_off_fin = 83.511 uV 14:09:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.463 uVs 14:09:42 I1Y Average and RMS of Measurements VT = -189.087 +- 1.149 uVs I1Y = -37.818 +- 0.230 uTm 14:09:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:09:50 Integrated Voltage Measurement... 14:09:59 Voltage Offset Correction: v_off_ini = 75.766 uV, v_off_fin = 67.577 uV 14:09:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.930 uVs 14:09:59 Integrated Voltage Measurement... 14:10:08 Voltage Offset Correction: v_off_ini = 62.554 uV, v_off_fin = 73.130 uV 14:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.805 uVs 14:10:08 Integrated Voltage Measurement... 14:10:17 Voltage Offset Correction: v_off_ini = 67.162 uV, v_off_fin = 60.695 uV 14:10:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.973 uVs 14:10:17 Integrated Voltage Measurement... 14:10:26 Voltage Offset Correction: v_off_ini = 76.383 uV, v_off_fin = 86.493 uV 14:10:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 46.782 uVs 14:10:26 Integrated Voltage Measurement... 14:10:35 Voltage Offset Correction: v_off_ini = 70.151 uV, v_off_fin = 84.464 uV 14:10:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.815 uVs 14:10:35 Integrated Voltage Measurement... 14:10:44 Voltage Offset Correction: v_off_ini = 87.943 uV, v_off_fin = 85.622 uV 14:10:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.161 uVs 14:10:47 I2X Average and RMS of Measurements VT = -55.577 +- 5.991 uVs I2X = 5.113 +- 0.551 uTm^2 14:10:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:10:54 Integrated Voltage Measurement... 14:11:03 Voltage Offset Correction: v_off_ini = 86.559 uV, v_off_fin = 90.543 uV 14:11:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -404.875 uVs 14:11:04 Integrated Voltage Measurement... 14:11:13 Voltage Offset Correction: v_off_ini = 86.541 uV, v_off_fin = 85.401 uV 14:11:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.041 uVs 14:11:13 Integrated Voltage Measurement... 14:11:22 Voltage Offset Correction: v_off_ini = 94.414 uV, v_off_fin = 96.076 uV 14:11:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.407 uVs 14:11:22 Integrated Voltage Measurement... 14:11:31 Voltage Offset Correction: v_off_ini = 104.205 uV, v_off_fin = 100.110 uV 14:11:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 410.634 uVs 14:11:31 Integrated Voltage Measurement... 14:11:40 Voltage Offset Correction: v_off_ini = 99.170 uV, v_off_fin = 105.613 uV 14:11:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -407.912 uVs 14:11:40 Integrated Voltage Measurement... 14:11:49 Voltage Offset Correction: v_off_ini = 94.186 uV, v_off_fin = 89.344 uV 14:11:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 393.300 uVs 14:11:51 I2Y Average and RMS of Measurements VT = -405.195 +- 3.820 uVs I2Y = -37.279 +- 0.351 uTm^2 14:11:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:12:00 Integrated Voltage Measurement... 14:12:09 Voltage Offset Correction: v_off_ini = 88.954 uV, v_off_fin = 95.217 uV 14:12:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.391 uVs 14:12:09 Integrated Voltage Measurement... 14:12:18 Voltage Offset Correction: v_off_ini = 102.715 uV, v_off_fin = 95.591 uV 14:12:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.475 uVs 14:12:18 Integrated Voltage Measurement... 14:12:27 Voltage Offset Correction: v_off_ini = 96.530 uV, v_off_fin = 103.737 uV 14:12:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.108 uVs 14:12:27 Integrated Voltage Measurement... 14:12:36 Voltage Offset Correction: v_off_ini = 103.401 uV, v_off_fin = 117.123 uV 14:12:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.416 uVs 14:12:36 Integrated Voltage Measurement... 14:12:45 Voltage Offset Correction: v_off_ini = 112.572 uV, v_off_fin = 98.992 uV 14:12:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.500 uVs 14:12:45 Integrated Voltage Measurement... 14:12:54 Voltage Offset Correction: v_off_ini = 93.021 uV, v_off_fin = 98.521 uV 14:12:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 67.643 uVs 14:12:58 I1X Average and RMS of Measurements VT = -79.256 +- 1.154 uVs I1X = 15.851 +- 0.231 uTm 14:13:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:13:05 Integrated Voltage Measurement... 14:13:14 Voltage Offset Correction: v_off_ini = 75.411 uV, v_off_fin = 80.006 uV 14:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.892 uVs 14:13:14 Integrated Voltage Measurement... 14:13:23 Voltage Offset Correction: v_off_ini = 83.069 uV, v_off_fin = 81.215 uV 14:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.808 uVs 14:13:23 Integrated Voltage Measurement... 14:13:32 Voltage Offset Correction: v_off_ini = 71.397 uV, v_off_fin = 63.707 uV 14:13:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.630 uVs 14:13:32 Integrated Voltage Measurement... 14:13:41 Voltage Offset Correction: v_off_ini = 84.641 uV, v_off_fin = 81.160 uV 14:13:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.290 uVs 14:13:41 Integrated Voltage Measurement... 14:13:50 Voltage Offset Correction: v_off_ini = 72.179 uV, v_off_fin = 77.707 uV 14:13:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.378 uVs 14:13:50 Integrated Voltage Measurement... 14:13:59 Voltage Offset Correction: v_off_ini = 71.020 uV, v_off_fin = 84.996 uV 14:13:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.957 uVs 14:14:03 I1Y Average and RMS of Measurements VT = -195.826 +- 4.656 uVs I1Y = -39.165 +- 0.931 uTm 14:14:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:14:11 Integrated Voltage Measurement... 14:14:20 Voltage Offset Correction: v_off_ini = 83.413 uV, v_off_fin = 69.843 uV 14:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.884 uVs 14:14:20 Integrated Voltage Measurement... 14:14:29 Voltage Offset Correction: v_off_ini = 75.984 uV, v_off_fin = 68.843 uV 14:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.792 uVs 14:14:29 Integrated Voltage Measurement... 14:14:38 Voltage Offset Correction: v_off_ini = 59.613 uV, v_off_fin = 63.533 uV 14:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.500 uVs 14:14:38 Integrated Voltage Measurement... 14:14:47 Voltage Offset Correction: v_off_ini = 79.184 uV, v_off_fin = 85.962 uV 14:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.468 uVs 14:14:47 Integrated Voltage Measurement... 14:14:56 Voltage Offset Correction: v_off_ini = 77.148 uV, v_off_fin = 68.190 uV 14:14:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.591 uVs 14:14:56 Integrated Voltage Measurement... 14:15:05 Voltage Offset Correction: v_off_ini = 77.603 uV, v_off_fin = 77.105 uV 14:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.992 uVs 14:15:08 I2X Average and RMS of Measurements VT = -64.205 +- 10.714 uVs I2X = 5.907 +- 0.986 uTm^2 14:15:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:15:16 Integrated Voltage Measurement... 14:15:25 Voltage Offset Correction: v_off_ini = 62.135 uV, v_off_fin = 61.509 uV 14:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -406.357 uVs 14:15:25 Integrated Voltage Measurement... 14:15:34 Voltage Offset Correction: v_off_ini = 61.943 uV, v_off_fin = 52.167 uV 14:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.629 uVs 14:15:34 Integrated Voltage Measurement... 14:15:43 Voltage Offset Correction: v_off_ini = 61.828 uV, v_off_fin = 69.133 uV 14:15:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -425.712 uVs 14:15:43 Integrated Voltage Measurement... 14:15:52 Voltage Offset Correction: v_off_ini = 46.366 uV, v_off_fin = 66.613 uV 14:15:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 424.584 uVs 14:15:52 Integrated Voltage Measurement... 14:16:01 Voltage Offset Correction: v_off_ini = 70.793 uV, v_off_fin = 63.236 uV 14:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -416.988 uVs 14:16:01 Integrated Voltage Measurement... 14:16:10 Voltage Offset Correction: v_off_ini = 57.117 uV, v_off_fin = 68.945 uV 14:16:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 394.588 uVs 14:16:12 I2Y Average and RMS of Measurements VT = -413.976 +- 8.180 uVs I2Y = -38.087 +- 0.753 uTm^2 14:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 67.712 uV, v_off_fin = 57.558 uV 14:16:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.909 uVs 14:16:30 Integrated Voltage Measurement... 14:16:39 Voltage Offset Correction: v_off_ini = 55.116 uV, v_off_fin = 63.020 uV 14:16:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.613 uVs 14:16:39 Integrated Voltage Measurement... 14:16:48 Voltage Offset Correction: v_off_ini = 53.882 uV, v_off_fin = 54.564 uV 14:16:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.285 uVs 14:16:48 Integrated Voltage Measurement... 14:16:57 Voltage Offset Correction: v_off_ini = 58.028 uV, v_off_fin = 65.306 uV 14:16:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.408 uVs 14:16:57 Integrated Voltage Measurement... 14:17:06 Voltage Offset Correction: v_off_ini = 48.226 uV, v_off_fin = 54.999 uV 14:17:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.976 uVs 14:17:06 Integrated Voltage Measurement... 14:17:15 Voltage Offset Correction: v_off_ini = 60.603 uV, v_off_fin = 49.292 uV 14:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.698 uVs 14:17:19 I1X Average and RMS of Measurements VT = -78.815 +- 8.625 uVs I1X = 15.764 +- 1.725 uTm 14:17:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:26 Integrated Voltage Measurement... 14:17:35 Voltage Offset Correction: v_off_ini = 54.327 uV, v_off_fin = 39.765 uV 14:17:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.049 uVs 14:17:35 Integrated Voltage Measurement... 14:17:44 Voltage Offset Correction: v_off_ini = 53.583 uV, v_off_fin = 51.617 uV 14:17:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.616 uVs 14:17:44 Integrated Voltage Measurement... 14:17:53 Voltage Offset Correction: v_off_ini = 58.309 uV, v_off_fin = 48.057 uV 14:17:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.726 uVs 14:17:53 Integrated Voltage Measurement... 14:18:02 Voltage Offset Correction: v_off_ini = 57.466 uV, v_off_fin = 62.702 uV 14:18:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.218 uVs 14:18:02 Integrated Voltage Measurement... 14:18:11 Voltage Offset Correction: v_off_ini = 49.681 uV, v_off_fin = 37.974 uV 14:18:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.890 uVs 14:18:11 Integrated Voltage Measurement... 14:18:20 Voltage Offset Correction: v_off_ini = 44.165 uV, v_off_fin = 47.744 uV 14:18:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.849 uVs 14:18:24 I1Y Average and RMS of Measurements VT = -182.891 +- 8.389 uVs I1Y = -36.578 +- 1.678 uTm 14:18:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:32 Integrated Voltage Measurement... 14:18:41 Voltage Offset Correction: v_off_ini = 34.813 uV, v_off_fin = 25.400 uV 14:18:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.481 uVs 14:18:41 Integrated Voltage Measurement... 14:18:50 Voltage Offset Correction: v_off_ini = 37.398 uV, v_off_fin = 32.026 uV 14:18:50 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 58.622 uVs 14:18:50 Integrated Voltage Measurement... 14:18:59 Voltage Offset Correction: v_off_ini = 26.555 uV, v_off_fin = 16.077 uV 14:18:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.827 uVs 14:18:59 Integrated Voltage Measurement... 14:19:08 Voltage Offset Correction: v_off_ini = 30.381 uV, v_off_fin = 37.830 uV 14:19:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.731 uVs 14:19:08 Integrated Voltage Measurement... 14:19:17 Voltage Offset Correction: v_off_ini = 26.982 uV, v_off_fin = 23.931 uV 14:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.863 uVs 14:19:17 Integrated Voltage Measurement... 14:19:26 Voltage Offset Correction: v_off_ini = 30.920 uV, v_off_fin = 37.421 uV 14:19:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.461 uVs 14:19:29 I2X Average and RMS of Measurements VT = -77.497 +- 7.032 uVs I2X = 7.130 +- 0.647 uTm^2 14:19:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:37 Integrated Voltage Measurement... 14:19:46 Voltage Offset Correction: v_off_ini = 33.145 uV, v_off_fin = 23.814 uV 14:19:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -413.637 uVs 14:19:46 Integrated Voltage Measurement... 14:19:55 Voltage Offset Correction: v_off_ini = 26.090 uV, v_off_fin = 27.652 uV 14:19:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 403.807 uVs 14:19:55 Integrated Voltage Measurement... 14:20:04 Voltage Offset Correction: v_off_ini = 28.302 uV, v_off_fin = 33.683 uV 14:20:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -405.159 uVs 14:20:04 Integrated Voltage Measurement... 14:20:13 Voltage Offset Correction: v_off_ini = 33.566 uV, v_off_fin = 8.895 uV 14:20:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.055 uVs 14:20:13 Integrated Voltage Measurement... 14:20:22 Voltage Offset Correction: v_off_ini = 18.413 uV, v_off_fin = 21.702 uV 14:20:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.796 uVs 14:20:22 Integrated Voltage Measurement... 14:20:31 Voltage Offset Correction: v_off_ini = 14.743 uV, v_off_fin = 21.491 uV 14:20:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.606 uVs 14:20:33 I2Y Average and RMS of Measurements VT = -404.010 +- 4.988 uVs I2Y = -37.169 +- 0.459 uTm^2 14:20:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:20:42 Integrated Voltage Measurement... 14:20:51 Voltage Offset Correction: v_off_ini = 31.423 uV, v_off_fin = 21.445 uV 14:20:51 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -98.285 uVs 14:20:51 Integrated Voltage Measurement... 14:21:00 Voltage Offset Correction: v_off_ini = 14.247 uV, v_off_fin = 25.223 uV 14:21:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.426 uVs 14:21:00 Integrated Voltage Measurement... 14:21:09 Voltage Offset Correction: v_off_ini = 10.962 uV, v_off_fin = 3.674 uV 14:21:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.350 uVs 14:21:09 Integrated Voltage Measurement... 14:21:18 Voltage Offset Correction: v_off_ini = 16.714 uV, v_off_fin = 25.251 uV 14:21:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.020 uVs 14:21:18 Integrated Voltage Measurement... 14:21:27 Voltage Offset Correction: v_off_ini = 23.441 uV, v_off_fin = 17.383 uV 14:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.916 uVs 14:21:27 Integrated Voltage Measurement... 14:21:36 Voltage Offset Correction: v_off_ini = 31.105 uV, v_off_fin = 41.902 uV 14:21:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.502 uVs 14:21:40 I1X Average and RMS of Measurements VT = -96.250 +- 2.460 uVs I1X = 19.252 +- 0.492 uTm 14:21:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:21:47 Integrated Voltage Measurement... 14:21:56 Voltage Offset Correction: v_off_ini = 31.050 uV, v_off_fin = 21.954 uV 14:21:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.667 uVs 14:21:56 Integrated Voltage Measurement... 14:22:05 Voltage Offset Correction: v_off_ini = 28.651 uV, v_off_fin = 38.370 uV 14:22:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.760 uVs 14:22:05 Integrated Voltage Measurement... 14:22:14 Voltage Offset Correction: v_off_ini = 27.784 uV, v_off_fin = 23.922 uV 14:22:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.329 uVs 14:22:14 Integrated Voltage Measurement... 14:22:23 Voltage Offset Correction: v_off_ini = 52.129 uV, v_off_fin = 46.864 uV 14:22:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.547 uVs 14:22:23 Integrated Voltage Measurement... 14:22:32 Voltage Offset Correction: v_off_ini = 36.341 uV, v_off_fin = 27.831 uV 14:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.371 uVs 14:22:32 Integrated Voltage Measurement... 14:22:41 Voltage Offset Correction: v_off_ini = 43.069 uV, v_off_fin = 40.643 uV 14:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.210 uVs 14:22:45 I1Y Average and RMS of Measurements VT = -185.814 +- 2.081 uVs I1Y = -37.163 +- 0.416 uTm 14:22:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:22:53 Integrated Voltage Measurement... 14:23:02 Voltage Offset Correction: v_off_ini = 32.714 uV, v_off_fin = 22.584 uV 14:23:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.469 uVs 14:23:02 Integrated Voltage Measurement... 14:23:11 Voltage Offset Correction: v_off_ini = 35.774 uV, v_off_fin = 50.371 uV 14:23:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.365 uVs 14:23:11 Integrated Voltage Measurement... 14:23:20 Voltage Offset Correction: v_off_ini = 32.425 uV, v_off_fin = 21.156 uV 14:23:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.878 uVs 14:23:20 Integrated Voltage Measurement... 14:23:29 Voltage Offset Correction: v_off_ini = 30.576 uV, v_off_fin = 35.059 uV 14:23:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.237 uVs 14:23:29 Integrated Voltage Measurement... 14:23:38 Voltage Offset Correction: v_off_ini = 31.779 uV, v_off_fin = 21.670 uV 14:23:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.512 uVs 14:23:38 Integrated Voltage Measurement... 14:23:47 Voltage Offset Correction: v_off_ini = 18.909 uV, v_off_fin = 25.739 uV 14:23:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.456 uVs 14:23:50 I2X Average and RMS of Measurements VT = -88.319 +- 6.173 uVs I2X = 8.125 +- 0.568 uTm^2 14:23:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:23:57 Integrated Voltage Measurement... 14:24:06 Voltage Offset Correction: v_off_ini = 26.647 uV, v_off_fin = 34.127 uV 14:24:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -401.343 uVs 14:24:06 Integrated Voltage Measurement... 14:24:15 Voltage Offset Correction: v_off_ini = 32.413 uV, v_off_fin = 31.677 uV 14:24:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.071 uVs 14:24:16 Integrated Voltage Measurement... 14:24:24 Voltage Offset Correction: v_off_ini = 15.087 uV, v_off_fin = 30.974 uV 14:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.913 uVs 14:24:25 Integrated Voltage Measurement... 14:24:34 Voltage Offset Correction: v_off_ini = 22.584 uV, v_off_fin = 19.730 uV 14:24:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 386.779 uVs 14:24:34 Integrated Voltage Measurement... 14:24:43 Voltage Offset Correction: v_off_ini = 28.950 uV, v_off_fin = 21.831 uV 14:24:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -395.559 uVs 14:24:43 Integrated Voltage Measurement... 14:24:52 Voltage Offset Correction: v_off_ini = 22.042 uV, v_off_fin = 28.820 uV 14:24:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 388.805 uVs 14:24:54 I2Y Average and RMS of Measurements VT = -387.912 +- 5.124 uVs I2Y = -35.688 +- 0.472 uTm^2 14:24:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:25:03 Integrated Voltage Measurement... 14:25:12 Voltage Offset Correction: v_off_ini = 27.253 uV, v_off_fin = 26.201 uV 14:25:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.344 uVs 14:25:12 Integrated Voltage Measurement... 14:25:21 Voltage Offset Correction: v_off_ini = 22.387 uV, v_off_fin = 27.457 uV 14:25:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 88.812 uVs 14:25:21 Integrated Voltage Measurement... 14:25:30 Voltage Offset Correction: v_off_ini = 17.055 uV, v_off_fin = 15.000 uV 14:25:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.422 uVs 14:25:30 Integrated Voltage Measurement... 14:25:39 Voltage Offset Correction: v_off_ini = 29.957 uV, v_off_fin = 37.985 uV 14:25:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 72.475 uVs 14:25:39 Integrated Voltage Measurement... 14:25:48 Voltage Offset Correction: v_off_ini = 37.886 uV, v_off_fin = 29.551 uV 14:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.062 uVs 14:25:48 Integrated Voltage Measurement... 14:25:57 Voltage Offset Correction: v_off_ini = 21.631 uV, v_off_fin = 37.325 uV 14:25:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.838 uVs 14:26:01 I1X Average and RMS of Measurements VT = -90.492 +- 3.900 uVs I1X = 18.100 +- 0.780 uTm 14:26:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:26:08 Integrated Voltage Measurement... 14:26:17 Voltage Offset Correction: v_off_ini = 34.713 uV, v_off_fin = 16.824 uV 14:26:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.826 uVs 14:26:17 Integrated Voltage Measurement... 14:26:26 Voltage Offset Correction: v_off_ini = 27.695 uV, v_off_fin = 27.170 uV 14:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.090 uVs 14:26:26 Integrated Voltage Measurement... 14:26:35 Voltage Offset Correction: v_off_ini = 31.263 uV, v_off_fin = 22.440 uV 14:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.660 uVs 14:26:35 Integrated Voltage Measurement... 14:26:44 Voltage Offset Correction: v_off_ini = 24.217 uV, v_off_fin = 33.955 uV 14:26:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.209 uVs 14:26:44 Integrated Voltage Measurement... 14:26:53 Voltage Offset Correction: v_off_ini = 30.535 uV, v_off_fin = 28.488 uV 14:26:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.098 uVs 14:26:53 Integrated Voltage Measurement... 14:27:02 Voltage Offset Correction: v_off_ini = 25.849 uV, v_off_fin = 34.476 uV 14:27:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.928 uVs 14:27:06 I1Y Average and RMS of Measurements VT = -184.802 +- 6.370 uVs I1Y = -36.960 +- 1.274 uTm 14:27:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:27:14 Integrated Voltage Measurement... 14:27:23 Voltage Offset Correction: v_off_ini = 25.864 uV, v_off_fin = 22.556 uV 14:27:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.265 uVs 14:27:23 Integrated Voltage Measurement... 14:27:32 Voltage Offset Correction: v_off_ini = 24.344 uV, v_off_fin = 43.935 uV 14:27:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.177 uVs 14:27:32 Integrated Voltage Measurement... 14:27:41 Voltage Offset Correction: v_off_ini = 23.866 uV, v_off_fin = 17.050 uV 14:27:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.643 uVs 14:27:41 Integrated Voltage Measurement... 14:27:50 Voltage Offset Correction: v_off_ini = 29.273 uV, v_off_fin = 44.057 uV 14:27:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.948 uVs 14:27:50 Integrated Voltage Measurement... 14:27:59 Voltage Offset Correction: v_off_ini = 33.282 uV, v_off_fin = 30.308 uV 14:27:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.037 uVs 14:27:59 Integrated Voltage Measurement... 14:28:08 Voltage Offset Correction: v_off_ini = 30.703 uV, v_off_fin = 41.063 uV 14:28:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.880 uVs 14:28:10 I2X Average and RMS of Measurements VT = -98.659 +- 14.443 uVs I2X = 9.076 +- 1.329 uTm^2 14:28:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:28:18 Integrated Voltage Measurement... 14:28:27 Voltage Offset Correction: v_off_ini = 21.571 uV, v_off_fin = 31.984 uV 14:28:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -375.522 uVs 14:28:27 Integrated Voltage Measurement... 14:28:36 Voltage Offset Correction: v_off_ini = 34.579 uV, v_off_fin = 24.570 uV 14:28:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.263 uVs 14:28:36 Integrated Voltage Measurement... 14:28:45 Voltage Offset Correction: v_off_ini = 20.655 uV, v_off_fin = 19.258 uV 14:28:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -386.852 uVs 14:28:45 Integrated Voltage Measurement... 14:28:54 Voltage Offset Correction: v_off_ini = 25.439 uV, v_off_fin = 29.344 uV 14:28:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.178 uVs 14:28:54 Integrated Voltage Measurement... 14:29:03 Voltage Offset Correction: v_off_ini = 33.219 uV, v_off_fin = 30.761 uV 14:29:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.160 uVs 14:29:03 Integrated Voltage Measurement... 14:29:12 Voltage Offset Correction: v_off_ini = 29.246 uV, v_off_fin = 29.529 uV 14:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.480 uVs 14:29:15 I2Y Average and RMS of Measurements VT = -383.909 +- 6.043 uVs I2Y = -35.320 +- 0.556 uTm^2 14:29:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:29:27 Integrated Voltage Measurement... 14:29:36 Voltage Offset Correction: v_off_ini = 39.138 uV, v_off_fin = 16.178 uV 14:29:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.990 uVs 14:29:36 Integrated Voltage Measurement... 14:29:45 Voltage Offset Correction: v_off_ini = 24.365 uV, v_off_fin = 31.293 uV 14:29:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.827 uVs 14:29:45 Integrated Voltage Measurement... 14:29:54 Voltage Offset Correction: v_off_ini = 30.932 uV, v_off_fin = 24.027 uV 14:29:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.452 uVs 14:29:54 Integrated Voltage Measurement... 14:30:03 Voltage Offset Correction: v_off_ini = 39.543 uV, v_off_fin = 44.638 uV 14:30:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.815 uVs 14:30:03 Integrated Voltage Measurement... 14:30:12 Voltage Offset Correction: v_off_ini = 28.370 uV, v_off_fin = 29.469 uV 14:30:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.519 uVs 14:30:12 Integrated Voltage Measurement... 14:30:21 Voltage Offset Correction: v_off_ini = 27.448 uV, v_off_fin = 40.139 uV 14:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.804 uVs 14:30:25 I1X Average and RMS of Measurements VT = -60.068 +- 6.877 uVs I1X = 12.014 +- 1.376 uTm 14:30:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:30:32 Integrated Voltage Measurement... 14:30:41 Voltage Offset Correction: v_off_ini = 36.977 uV, v_off_fin = 22.652 uV 14:30:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -183.042 uVs 14:30:41 Integrated Voltage Measurement... 14:30:50 Voltage Offset Correction: v_off_ini = 27.866 uV, v_off_fin = 30.767 uV 14:30:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.448 uVs 14:30:50 Integrated Voltage Measurement... 14:30:59 Voltage Offset Correction: v_off_ini = 34.447 uV, v_off_fin = 23.234 uV 14:30:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.328 uVs 14:30:59 Integrated Voltage Measurement... 14:31:08 Voltage Offset Correction: v_off_ini = 32.174 uV, v_off_fin = 37.666 uV 14:31:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.105 uVs 14:31:08 Integrated Voltage Measurement... 14:31:16 Voltage Offset Correction: v_off_ini = 26.725 uV, v_off_fin = 21.307 uV 14:31:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.891 uVs 14:31:17 Integrated Voltage Measurement... 14:31:25 Voltage Offset Correction: v_off_ini = 25.114 uV, v_off_fin = 47.728 uV 14:31:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.271 uVs 14:31:30 I1Y Average and RMS of Measurements VT = -179.181 +- 5.676 uVs I1Y = -35.837 +- 1.135 uTm 14:31:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:31:35 Integrated Voltage Measurement... 14:31:44 Voltage Offset Correction: v_off_ini = 32.654 uV, v_off_fin = 30.395 uV 14:31:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -66.689 uVs 14:31:44 Integrated Voltage Measurement... 14:31:53 Voltage Offset Correction: v_off_ini = 38.504 uV, v_off_fin = 38.361 uV 14:31:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.738 uVs 14:31:53 Integrated Voltage Measurement... 14:32:02 Voltage Offset Correction: v_off_ini = 17.331 uV, v_off_fin = 17.477 uV 14:32:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.029 uVs 14:32:02 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = 22.887 uV, v_off_fin = 28.038 uV 14:32:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.349 uVs 14:32:11 Integrated Voltage Measurement... 14:32:20 Voltage Offset Correction: v_off_ini = 28.394 uV, v_off_fin = 18.613 uV 14:32:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.813 uVs 14:32:20 Integrated Voltage Measurement... 14:32:29 Voltage Offset Correction: v_off_ini = 24.326 uV, v_off_fin = 34.784 uV 14:32:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.387 uVs 14:32:31 I2X Average and RMS of Measurements VT = -65.334 +- 9.022 uVs I2X = 6.011 +- 0.830 uTm^2 14:32:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:32:36 Integrated Voltage Measurement... 14:32:45 Voltage Offset Correction: v_off_ini = 28.735 uV, v_off_fin = 12.780 uV 14:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.566 uVs 14:32:45 Integrated Voltage Measurement... 14:32:54 Voltage Offset Correction: v_off_ini = 33.211 uV, v_off_fin = 40.681 uV 14:32:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 386.330 uVs 14:32:55 Integrated Voltage Measurement... 14:33:03 Voltage Offset Correction: v_off_ini = 31.756 uV, v_off_fin = 40.858 uV 14:33:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -388.741 uVs 14:33:04 Integrated Voltage Measurement... 14:33:13 Voltage Offset Correction: v_off_ini = 40.302 uV, v_off_fin = 33.925 uV 14:33:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 411.732 uVs 14:33:13 Integrated Voltage Measurement... 14:33:22 Voltage Offset Correction: v_off_ini = 30.092 uV, v_off_fin = 29.868 uV 14:33:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.444 uVs 14:33:22 Integrated Voltage Measurement... 14:33:31 Voltage Offset Correction: v_off_ini = 30.038 uV, v_off_fin = 32.964 uV 14:33:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 388.437 uVs 14:33:33 I2Y Average and RMS of Measurements VT = -393.375 +- 4.920 uVs I2Y = -36.190 +- 0.453 uTm^2 14:33:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:33:41 Integrated Voltage Measurement... 14:33:50 Voltage Offset Correction: v_off_ini = 27.500 uV, v_off_fin = 26.680 uV 14:33:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.194 uVs 14:33:50 Integrated Voltage Measurement... 14:33:59 Voltage Offset Correction: v_off_ini = 23.127 uV, v_off_fin = 33.196 uV 14:33:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.248 uVs 14:33:59 Integrated Voltage Measurement... 14:34:08 Voltage Offset Correction: v_off_ini = 20.371 uV, v_off_fin = 26.369 uV 14:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.580 uVs 14:34:08 Integrated Voltage Measurement... 14:34:17 Voltage Offset Correction: v_off_ini = 35.871 uV, v_off_fin = 21.460 uV 14:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.079 uVs 14:34:17 Integrated Voltage Measurement... 14:34:26 Voltage Offset Correction: v_off_ini = 26.549 uV, v_off_fin = 13.770 uV 14:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.149 uVs 14:34:26 Integrated Voltage Measurement... 14:34:35 Voltage Offset Correction: v_off_ini = 18.219 uV, v_off_fin = 33.165 uV 14:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.890 uVs 14:34:40 I1X Average and RMS of Measurements VT = -79.523 +- 5.826 uVs I1X = 15.905 +- 1.165 uTm 14:34:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:34:46 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = 16.373 uV, v_off_fin = 12.328 uV 14:34:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -167.890 uVs 14:34:55 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = 26.827 uV, v_off_fin = 42.785 uV 14:35:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.418 uVs 14:35:04 Integrated Voltage Measurement... 14:35:13 Voltage Offset Correction: v_off_ini = 30.957 uV, v_off_fin = 25.745 uV 14:35:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.627 uVs 14:35:13 Integrated Voltage Measurement... 14:35:22 Voltage Offset Correction: v_off_ini = 29.294 uV, v_off_fin = 20.918 uV 14:35:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.774 uVs 14:35:22 Integrated Voltage Measurement... 14:35:31 Voltage Offset Correction: v_off_ini = 29.396 uV, v_off_fin = 35.024 uV 14:35:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.188 uVs 14:35:31 Integrated Voltage Measurement... 14:35:40 Voltage Offset Correction: v_off_ini = 34.169 uV, v_off_fin = 30.776 uV 14:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.118 uVs 14:35:44 I1Y Average and RMS of Measurements VT = -182.169 +- 4.961 uVs I1Y = -36.435 +- 0.991 uTm 14:35:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:35:50 Integrated Voltage Measurement... 14:35:58 Voltage Offset Correction: v_off_ini = 41.543 uV, v_off_fin = 46.649 uV 14:35:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.357 uVs 14:35:59 Integrated Voltage Measurement... 14:36:08 Voltage Offset Correction: v_off_ini = 58.600 uV, v_off_fin = 63.725 uV 14:36:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.447 uVs 14:36:08 Integrated Voltage Measurement... 14:36:17 Voltage Offset Correction: v_off_ini = 36.053 uV, v_off_fin = 14.774 uV 14:36:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.553 uVs 14:36:17 Integrated Voltage Measurement... 14:36:26 Voltage Offset Correction: v_off_ini = 30.323 uV, v_off_fin = 43.500 uV 14:36:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.182 uVs 14:36:26 Integrated Voltage Measurement... 14:36:35 Voltage Offset Correction: v_off_ini = 12.954 uV, v_off_fin = 5.167 uV 14:36:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.644 uVs 14:36:35 Integrated Voltage Measurement... 14:36:44 Voltage Offset Correction: v_off_ini = 15.609 uV, v_off_fin = 31.967 uV 14:36:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.931 uVs 14:36:46 I2X Average and RMS of Measurements VT = -77.519 +- 2.344 uVs I2X = 7.132 +- 0.216 uTm^2 14:36:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:36:51 Integrated Voltage Measurement... 14:37:00 Voltage Offset Correction: v_off_ini = 27.593 uV, v_off_fin = 29.000 uV 14:37:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -403.628 uVs 14:37:00 Integrated Voltage Measurement... 14:37:09 Voltage Offset Correction: v_off_ini = 21.518 uV, v_off_fin = 21.760 uV 14:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.658 uVs 14:37:09 Integrated Voltage Measurement... 14:37:18 Voltage Offset Correction: v_off_ini = 38.959 uV, v_off_fin = 31.285 uV 14:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.640 uVs 14:37:18 Integrated Voltage Measurement... 14:37:27 Voltage Offset Correction: v_off_ini = 28.061 uV, v_off_fin = 30.023 uV 14:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.238 uVs 14:37:27 Integrated Voltage Measurement... 14:37:36 Voltage Offset Correction: v_off_ini = 18.188 uV, v_off_fin = 16.775 uV 14:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -395.126 uVs 14:37:36 Integrated Voltage Measurement... 14:37:45 Voltage Offset Correction: v_off_ini = 34.491 uV, v_off_fin = 33.063 uV 14:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.564 uVs 14:37:48 I2Y Average and RMS of Measurements VT = -406.809 +- 14.517 uVs I2Y = -37.426 +- 1.336 uTm^2 14:37:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 24.863 uV, v_off_fin = 27.135 uV 14:38:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -101.296 uVs 14:38:05 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = 31.663 uV, v_off_fin = 33.020 uV 14:38:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.356 uVs 14:38:14 Integrated Voltage Measurement... 14:38:23 Voltage Offset Correction: v_off_ini = 18.910 uV, v_off_fin = 21.530 uV 14:38:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.009 uVs 14:38:23 Integrated Voltage Measurement... 14:38:32 Voltage Offset Correction: v_off_ini = 21.772 uV, v_off_fin = 24.691 uV 14:38:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.078 uVs 14:38:32 Integrated Voltage Measurement... 14:38:41 Voltage Offset Correction: v_off_ini = 24.114 uV, v_off_fin = 30.290 uV 14:38:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -86.729 uVs 14:38:41 Integrated Voltage Measurement... 14:38:50 Voltage Offset Correction: v_off_ini = 41.175 uV, v_off_fin = 42.852 uV 14:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 72.403 uVs 14:38:54 I1X Average and RMS of Measurements VT = -87.145 +- 5.629 uVs I1X = 17.431 +- 1.125 uTm 14:38:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:01 Integrated Voltage Measurement... 14:39:10 Voltage Offset Correction: v_off_ini = 31.785 uV, v_off_fin = 16.118 uV 14:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.544 uVs 14:39:10 Integrated Voltage Measurement... 14:39:19 Voltage Offset Correction: v_off_ini = 36.899 uV, v_off_fin = 37.764 uV 14:39:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.962 uVs 14:39:19 Integrated Voltage Measurement... 14:39:28 Voltage Offset Correction: v_off_ini = 34.317 uV, v_off_fin = 17.012 uV 14:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.048 uVs 14:39:28 Integrated Voltage Measurement... 14:39:37 Voltage Offset Correction: v_off_ini = 44.128 uV, v_off_fin = 53.013 uV 14:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.342 uVs 14:39:37 Integrated Voltage Measurement... 14:39:46 Voltage Offset Correction: v_off_ini = 23.220 uV, v_off_fin = 14.794 uV 14:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.517 uVs 14:39:46 Integrated Voltage Measurement... 14:39:55 Voltage Offset Correction: v_off_ini = 32.906 uV, v_off_fin = 42.155 uV 14:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.367 uVs 14:39:59 I1Y Average and RMS of Measurements VT = -179.963 +- 5.356 uVs I1Y = -35.993 +- 1.071 uTm 14:40:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:04 Integrated Voltage Measurement... 14:40:13 Voltage Offset Correction: v_off_ini = 45.838 uV, v_off_fin = 36.665 uV 14:40:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.775 uVs 14:40:13 Integrated Voltage Measurement... 14:40:22 Voltage Offset Correction: v_off_ini = 31.178 uV, v_off_fin = 30.410 uV 14:40:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.601 uVs 14:40:22 Integrated Voltage Measurement... 14:40:31 Voltage Offset Correction: v_off_ini = 19.050 uV, v_off_fin = 20.417 uV 14:40:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.784 uVs 14:40:31 Integrated Voltage Measurement... 14:40:40 Voltage Offset Correction: v_off_ini = 46.200 uV, v_off_fin = 45.462 uV 14:40:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.824 uVs 14:40:40 Integrated Voltage Measurement... 14:40:49 Voltage Offset Correction: v_off_ini = 28.431 uV, v_off_fin = 27.942 uV 14:40:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.531 uVs 14:40:49 Integrated Voltage Measurement... 14:40:58 Voltage Offset Correction: v_off_ini = 27.778 uV, v_off_fin = 46.268 uV 14:40:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.464 uVs 14:41:01 I2X Average and RMS of Measurements VT = -88.163 +- 5.671 uVs I2X = 8.111 +- 0.522 uTm^2 14:41:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:06 Integrated Voltage Measurement... 14:41:15 Voltage Offset Correction: v_off_ini = 42.724 uV, v_off_fin = 23.786 uV 14:41:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -400.936 uVs 14:41:15 Integrated Voltage Measurement... 14:41:24 Voltage Offset Correction: v_off_ini = 42.366 uV, v_off_fin = 41.968 uV 14:41:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.962 uVs 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 42.555 uV, v_off_fin = 26.948 uV 14:41:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -405.482 uVs 14:41:33 Integrated Voltage Measurement... 14:41:42 Voltage Offset Correction: v_off_ini = 29.682 uV, v_off_fin = 30.962 uV 14:41:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.463 uVs 14:41:42 Integrated Voltage Measurement... 14:41:51 Voltage Offset Correction: v_off_ini = 29.304 uV, v_off_fin = 38.921 uV 14:41:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.683 uVs 14:41:51 Integrated Voltage Measurement... 14:42:00 Voltage Offset Correction: v_off_ini = 45.872 uV, v_off_fin = 49.520 uV 14:42:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.487 uVs 14:42:03 I2Y Average and RMS of Measurements VT = -394.169 +- 3.734 uVs I2Y = -36.264 +- 0.344 uTm^2 14:42:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:42:11 Integrated Voltage Measurement... 14:42:20 Voltage Offset Correction: v_off_ini = 53.955 uV, v_off_fin = 34.228 uV 14:42:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -95.107 uVs 14:42:20 Integrated Voltage Measurement... 14:42:29 Voltage Offset Correction: v_off_ini = 48.492 uV, v_off_fin = 41.393 uV 14:42:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.305 uVs 14:42:29 Integrated Voltage Measurement... 14:42:38 Voltage Offset Correction: v_off_ini = 40.564 uV, v_off_fin = 45.401 uV 14:42:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.172 uVs 14:42:38 Integrated Voltage Measurement... 14:42:47 Voltage Offset Correction: v_off_ini = 48.685 uV, v_off_fin = 36.073 uV 14:42:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.411 uVs 14:42:47 Integrated Voltage Measurement... 14:42:56 Voltage Offset Correction: v_off_ini = 48.343 uV, v_off_fin = 42.805 uV 14:42:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.460 uVs 14:42:56 Integrated Voltage Measurement... 14:43:05 Voltage Offset Correction: v_off_ini = 47.500 uV, v_off_fin = 43.240 uV 14:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.818 uVs 14:43:09 I1X Average and RMS of Measurements VT = -89.712 +- 5.012 uVs I1X = 17.943 +- 1.002 uTm 14:43:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:43:16 Integrated Voltage Measurement... 14:43:25 Voltage Offset Correction: v_off_ini = 47.673 uV, v_off_fin = 37.370 uV 14:43:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.904 uVs 14:43:25 Integrated Voltage Measurement... 14:43:34 Voltage Offset Correction: v_off_ini = 44.448 uV, v_off_fin = 48.845 uV 14:43:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.258 uVs 14:43:34 Integrated Voltage Measurement... 14:43:43 Voltage Offset Correction: v_off_ini = 27.582 uV, v_off_fin = 17.128 uV 14:43:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.895 uVs 14:43:43 Integrated Voltage Measurement... 14:43:52 Voltage Offset Correction: v_off_ini = 33.521 uV, v_off_fin = 39.206 uV 14:43:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.414 uVs 14:43:52 Integrated Voltage Measurement... 14:44:01 Voltage Offset Correction: v_off_ini = 33.464 uV, v_off_fin = 24.464 uV 14:44:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.246 uVs 14:44:01 Integrated Voltage Measurement... 14:44:10 Voltage Offset Correction: v_off_ini = 38.925 uV, v_off_fin = 49.143 uV 14:44:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.569 uVs 14:44:14 I1Y Average and RMS of Measurements VT = -185.881 +- 1.867 uVs I1Y = -37.174 +- 0.374 uTm 14:44:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = 19.821 uV, v_off_fin = 17.714 uV 14:44:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.942 uVs 14:44:28 Integrated Voltage Measurement... 14:44:37 Voltage Offset Correction: v_off_ini = 22.186 uV, v_off_fin = 39.580 uV 14:44:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.557 uVs 14:44:37 Integrated Voltage Measurement... 14:44:46 Voltage Offset Correction: v_off_ini = 33.607 uV, v_off_fin = 16.458 uV 14:44:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.869 uVs 14:44:47 Integrated Voltage Measurement... 14:44:55 Voltage Offset Correction: v_off_ini = 29.206 uV, v_off_fin = 42.716 uV 14:44:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.485 uVs 14:44:56 Integrated Voltage Measurement... 14:45:05 Voltage Offset Correction: v_off_ini = 26.291 uV, v_off_fin = 49.042 uV 14:45:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.127 uVs 14:45:05 Integrated Voltage Measurement... 14:45:14 Voltage Offset Correction: v_off_ini = 56.923 uV, v_off_fin = 67.918 uV 14:45:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.117 uVs 14:45:16 I2X Average and RMS of Measurements VT = -82.016 +- 5.761 uVs I2X = 7.546 +- 0.530 uTm^2 14:45:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:45:21 Integrated Voltage Measurement... 14:45:30 Voltage Offset Correction: v_off_ini = 55.034 uV, v_off_fin = 44.664 uV 14:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -400.107 uVs 14:45:30 Integrated Voltage Measurement... 14:45:39 Voltage Offset Correction: v_off_ini = 55.984 uV, v_off_fin = 40.868 uV 14:45:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.882 uVs 14:45:39 Integrated Voltage Measurement... 14:45:48 Voltage Offset Correction: v_off_ini = 41.169 uV, v_off_fin = 51.880 uV 14:45:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.244 uVs 14:45:48 Integrated Voltage Measurement... 14:45:57 Voltage Offset Correction: v_off_ini = 61.939 uV, v_off_fin = 54.342 uV 14:45:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 423.333 uVs 14:45:57 Integrated Voltage Measurement... 14:46:06 Voltage Offset Correction: v_off_ini = 66.575 uV, v_off_fin = 60.901 uV 14:46:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -421.050 uVs 14:46:06 Integrated Voltage Measurement... 14:46:15 Voltage Offset Correction: v_off_ini = 58.145 uV, v_off_fin = 42.643 uV 14:46:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.544 uVs 14:46:18 I2Y Average and RMS of Measurements VT = -409.527 +- 5.302 uVs I2Y = -37.676 +- 0.488 uTm^2 14:46:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:46:26 Integrated Voltage Measurement... 14:46:35 Voltage Offset Correction: v_off_ini = 45.151 uV, v_off_fin = 55.714 uV 14:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.482 uVs 14:46:35 Integrated Voltage Measurement... 14:46:44 Voltage Offset Correction: v_off_ini = 53.149 uV, v_off_fin = 53.816 uV 14:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.215 uVs 14:46:44 Integrated Voltage Measurement... 14:46:53 Voltage Offset Correction: v_off_ini = 46.738 uV, v_off_fin = 49.238 uV 14:46:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.462 uVs 14:46:53 Integrated Voltage Measurement... 14:47:02 Voltage Offset Correction: v_off_ini = 58.842 uV, v_off_fin = 72.001 uV 14:47:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.297 uVs 14:47:02 Integrated Voltage Measurement... 14:47:11 Voltage Offset Correction: v_off_ini = 60.225 uV, v_off_fin = 60.132 uV 14:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.690 uVs 14:47:11 Integrated Voltage Measurement... 14:47:20 Voltage Offset Correction: v_off_ini = 72.896 uV, v_off_fin = 64.830 uV 14:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.989 uVs 14:47:24 I1X Average and RMS of Measurements VT = -74.189 +- 6.233 uVs I1X = 14.838 +- 1.246 uTm 14:47:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:47:31 Integrated Voltage Measurement... 14:47:40 Voltage Offset Correction: v_off_ini = 58.034 uV, v_off_fin = 45.819 uV 14:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.021 uVs 14:47:40 Integrated Voltage Measurement... 14:47:49 Voltage Offset Correction: v_off_ini = 64.202 uV, v_off_fin = 62.111 uV 14:47:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.710 uVs 14:47:49 Integrated Voltage Measurement... 14:47:58 Voltage Offset Correction: v_off_ini = 60.741 uV, v_off_fin = 43.419 uV 14:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.871 uVs 14:47:58 Integrated Voltage Measurement... 14:48:07 Voltage Offset Correction: v_off_ini = 53.531 uV, v_off_fin = 55.088 uV 14:48:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.270 uVs 14:48:07 Integrated Voltage Measurement... 14:48:16 Voltage Offset Correction: v_off_ini = 60.733 uV, v_off_fin = 46.974 uV 14:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.474 uVs 14:48:16 Integrated Voltage Measurement... 14:48:25 Voltage Offset Correction: v_off_ini = 71.103 uV, v_off_fin = 65.388 uV 14:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.637 uVs 14:48:29 I1Y Average and RMS of Measurements VT = -192.831 +- 8.545 uVs I1Y = -38.563 +- 1.708 uTm 14:48:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:48:35 Integrated Voltage Measurement... 14:48:44 Voltage Offset Correction: v_off_ini = 66.665 uV, v_off_fin = 57.763 uV 14:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.293 uVs 14:48:44 Integrated Voltage Measurement... 14:48:53 Voltage Offset Correction: v_off_ini = 65.089 uV, v_off_fin = 70.574 uV 14:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.051 uVs 14:48:53 Integrated Voltage Measurement... 14:49:02 Voltage Offset Correction: v_off_ini = 52.596 uV, v_off_fin = 44.067 uV 14:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.476 uVs 14:49:02 Integrated Voltage Measurement... 14:49:11 Voltage Offset Correction: v_off_ini = 52.478 uV, v_off_fin = 63.177 uV 14:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.955 uVs 14:49:11 Integrated Voltage Measurement... 14:49:20 Voltage Offset Correction: v_off_ini = 54.907 uV, v_off_fin = 38.252 uV 14:49:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.250 uVs 14:49:20 Integrated Voltage Measurement... 14:49:29 Voltage Offset Correction: v_off_ini = 57.451 uV, v_off_fin = 66.556 uV 14:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.549 uVs 14:49:31 I2X Average and RMS of Measurements VT = -85.262 +- 8.542 uVs I2X = 7.844 +- 0.786 uTm^2 14:49:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:49:36 Integrated Voltage Measurement... 14:49:45 Voltage Offset Correction: v_off_ini = 57.702 uV, v_off_fin = 63.125 uV 14:49:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.423 uVs 14:49:45 Integrated Voltage Measurement... 14:49:54 Voltage Offset Correction: v_off_ini = 55.317 uV, v_off_fin = 63.390 uV 14:49:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.936 uVs 14:49:55 Integrated Voltage Measurement... 14:50:04 Voltage Offset Correction: v_off_ini = 63.135 uV, v_off_fin = 73.762 uV 14:50:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.740 uVs 14:50:04 Integrated Voltage Measurement... 14:50:13 Voltage Offset Correction: v_off_ini = 77.382 uV, v_off_fin = 65.379 uV 14:50:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.640 uVs 14:50:13 Integrated Voltage Measurement... 14:50:22 Voltage Offset Correction: v_off_ini = 70.684 uV, v_off_fin = 60.386 uV 14:50:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -416.140 uVs 14:50:22 Integrated Voltage Measurement... 14:50:31 Voltage Offset Correction: v_off_ini = 69.037 uV, v_off_fin = 50.843 uV 14:50:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.992 uVs 14:50:33 I2Y Average and RMS of Measurements VT = -414.478 +- 2.364 uVs I2Y = -38.132 +- 0.218 uTm^2 14:50:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:50:54 Integrated Voltage Measurement... 14:51:03 Voltage Offset Correction: v_off_ini = 80.211 uV, v_off_fin = 72.629 uV 14:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.702 uVs 14:51:03 Integrated Voltage Measurement... 14:51:12 Voltage Offset Correction: v_off_ini = 73.926 uV, v_off_fin = 79.512 uV 14:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.385 uVs 14:51:12 Integrated Voltage Measurement... 14:51:21 Voltage Offset Correction: v_off_ini = 76.286 uV, v_off_fin = 66.745 uV 14:51:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.662 uVs 14:51:21 Integrated Voltage Measurement... 14:51:30 Voltage Offset Correction: v_off_ini = 61.185 uV, v_off_fin = 71.122 uV 14:51:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.883 uVs 14:51:30 Integrated Voltage Measurement... 14:51:39 Voltage Offset Correction: v_off_ini = 76.035 uV, v_off_fin = 68.352 uV 14:51:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.331 uVs 14:51:39 Integrated Voltage Measurement... 14:51:48 Voltage Offset Correction: v_off_ini = 92.798 uV, v_off_fin = 84.283 uV 14:51:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.298 uVs 14:51:53 I1X Average and RMS of Measurements VT = -58.710 +- 11.056 uVs I1X = 11.742 +- 2.211 uTm 14:51:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:51:59 Integrated Voltage Measurement... 14:52:08 Voltage Offset Correction: v_off_ini = 76.987 uV, v_off_fin = 67.414 uV 14:52:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -186.568 uVs 14:52:08 Integrated Voltage Measurement... 14:52:17 Voltage Offset Correction: v_off_ini = 70.618 uV, v_off_fin = 70.183 uV 14:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.620 uVs 14:52:17 Integrated Voltage Measurement... 14:52:26 Voltage Offset Correction: v_off_ini = 78.568 uV, v_off_fin = 69.892 uV 14:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.234 uVs 14:52:26 Integrated Voltage Measurement... 14:52:35 Voltage Offset Correction: v_off_ini = 78.279 uV, v_off_fin = 81.456 uV 14:52:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.717 uVs 14:52:36 Integrated Voltage Measurement... 14:52:44 Voltage Offset Correction: v_off_ini = 78.018 uV, v_off_fin = 60.958 uV 14:52:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.601 uVs 14:52:45 Integrated Voltage Measurement... 14:52:53 Voltage Offset Correction: v_off_ini = 60.240 uV, v_off_fin = 77.241 uV 14:52:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 189.986 uVs 14:52:58 I1Y Average and RMS of Measurements VT = -179.954 +- 5.015 uVs I1Y = -35.993 +- 1.005 uTm 14:53:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:53:05 Integrated Voltage Measurement... 14:53:14 Voltage Offset Correction: v_off_ini = 79.083 uV, v_off_fin = 62.995 uV 14:53:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -52.497 uVs 14:53:14 Integrated Voltage Measurement... 14:53:23 Voltage Offset Correction: v_off_ini = 78.959 uV, v_off_fin = 75.122 uV 14:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.007 uVs 14:53:24 Integrated Voltage Measurement... 14:53:32 Voltage Offset Correction: v_off_ini = 81.252 uV, v_off_fin = 52.126 uV 14:53:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.101 uVs 14:53:33 Integrated Voltage Measurement... 14:53:42 Voltage Offset Correction: v_off_ini = 57.396 uV, v_off_fin = 62.257 uV 14:53:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.471 uVs 14:53:42 Integrated Voltage Measurement... 14:53:51 Voltage Offset Correction: v_off_ini = 49.541 uV, v_off_fin = 52.353 uV 14:53:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.426 uVs 14:53:51 Integrated Voltage Measurement... 14:54:00 Voltage Offset Correction: v_off_ini = 72.001 uV, v_off_fin = 54.821 uV 14:54:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.251 uVs 14:54:02 I2X Average and RMS of Measurements VT = -51.625 +- 9.105 uVs I2X = 4.750 +- 0.838 uTm^2 14:54:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:54:10 Integrated Voltage Measurement... 14:54:19 Voltage Offset Correction: v_off_ini = 44.770 uV, v_off_fin = 51.924 uV 14:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.875 uVs 14:54:19 Integrated Voltage Measurement... 14:54:28 Voltage Offset Correction: v_off_ini = 51.006 uV, v_off_fin = 52.505 uV 14:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.614 uVs 14:54:28 Integrated Voltage Measurement... 14:54:37 Voltage Offset Correction: v_off_ini = 36.325 uV, v_off_fin = 51.559 uV 14:54:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.797 uVs 14:54:37 Integrated Voltage Measurement... 14:54:46 Voltage Offset Correction: v_off_ini = 42.892 uV, v_off_fin = 52.347 uV 14:54:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.001 uVs 14:54:46 Integrated Voltage Measurement... 14:54:55 Voltage Offset Correction: v_off_ini = 51.905 uV, v_off_fin = 36.806 uV 14:54:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.875 uVs 14:54:55 Integrated Voltage Measurement... 14:55:04 Voltage Offset Correction: v_off_ini = 30.270 uV, v_off_fin = 44.070 uV 14:55:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.021 uVs 14:55:06 I2Y Average and RMS of Measurements VT = -378.364 +- 8.656 uVs I2Y = -34.809 +- 0.796 uTm^2 14:55:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:55:15 Integrated Voltage Measurement... 14:55:24 Voltage Offset Correction: v_off_ini = 52.075 uV, v_off_fin = 24.695 uV 14:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.335 uVs 14:55:24 Integrated Voltage Measurement... 14:55:33 Voltage Offset Correction: v_off_ini = 28.758 uV, v_off_fin = 25.295 uV 14:55:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.999 uVs 14:55:33 Integrated Voltage Measurement... 14:55:42 Voltage Offset Correction: v_off_ini = 21.047 uV, v_off_fin = 24.966 uV 14:55:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.083 uVs 14:55:42 Integrated Voltage Measurement... 14:55:51 Voltage Offset Correction: v_off_ini = 34.205 uV, v_off_fin = 41.520 uV 14:55:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.719 uVs 14:55:51 Integrated Voltage Measurement... 14:56:00 Voltage Offset Correction: v_off_ini = 15.953 uV, v_off_fin = 29.298 uV 14:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.393 uVs 14:56:01 Integrated Voltage Measurement... 14:56:09 Voltage Offset Correction: v_off_ini = 22.713 uV, v_off_fin = 29.660 uV 14:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.356 uVs 14:56:14 I1X Average and RMS of Measurements VT = -52.481 +- 12.132 uVs I1X = 10.496 +- 2.426 uTm 14:56:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:56:21 Integrated Voltage Measurement... 14:56:29 Voltage Offset Correction: v_off_ini = 19.905 uV, v_off_fin = 25.232 uV 14:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.632 uVs 14:56:30 Integrated Voltage Measurement... 14:56:38 Voltage Offset Correction: v_off_ini = 31.387 uV, v_off_fin = 20.228 uV 14:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.824 uVs 14:56:39 Integrated Voltage Measurement... 14:56:47 Voltage Offset Correction: v_off_ini = 33.023 uV, v_off_fin = 18.912 uV 14:56:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.401 uVs 14:56:48 Integrated Voltage Measurement... 14:56:56 Voltage Offset Correction: v_off_ini = 29.759 uV, v_off_fin = 26.201 uV 14:56:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.352 uVs 14:56:57 Integrated Voltage Measurement... 14:57:05 Voltage Offset Correction: v_off_ini = 29.870 uV, v_off_fin = 15.990 uV 14:57:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.139 uVs 14:57:06 Integrated Voltage Measurement... 14:57:14 Voltage Offset Correction: v_off_ini = 37.149 uV, v_off_fin = 28.542 uV 14:57:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.081 uVs 14:57:19 I1Y Average and RMS of Measurements VT = -186.571 +- 2.288 uVs I1Y = -37.314 +- 0.458 uTm 14:57:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:57:26 Integrated Voltage Measurement... 14:57:35 Voltage Offset Correction: v_off_ini = 16.364 uV, v_off_fin = 21.816 uV 14:57:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.310 uVs 14:57:35 Integrated Voltage Measurement... 14:57:44 Voltage Offset Correction: v_off_ini = 23.769 uV, v_off_fin = 24.866 uV 14:57:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.028 uVs 14:57:45 Integrated Voltage Measurement... 14:57:53 Voltage Offset Correction: v_off_ini = 20.252 uV, v_off_fin = 26.791 uV 14:57:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.308 uVs 14:57:54 Integrated Voltage Measurement... 14:58:03 Voltage Offset Correction: v_off_ini = 35.695 uV, v_off_fin = 35.534 uV 14:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.770 uVs 14:58:03 Integrated Voltage Measurement... 14:58:12 Voltage Offset Correction: v_off_ini = 33.645 uV, v_off_fin = 30.041 uV 14:58:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.943 uVs 14:58:12 Integrated Voltage Measurement... 14:58:21 Voltage Offset Correction: v_off_ini = 46.516 uV, v_off_fin = 37.678 uV 14:58:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 40.059 uVs 14:58:23 I2X Average and RMS of Measurements VT = -51.570 +- 7.024 uVs I2X = 4.744 +- 0.646 uTm^2 14:58:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:58:31 Integrated Voltage Measurement... 14:58:40 Voltage Offset Correction: v_off_ini = 15.595 uV, v_off_fin = 26.346 uV 14:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.885 uVs 14:58:40 Integrated Voltage Measurement... 14:58:49 Voltage Offset Correction: v_off_ini = 42.518 uV, v_off_fin = 28.234 uV 14:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.968 uVs 14:58:49 Integrated Voltage Measurement... 14:58:58 Voltage Offset Correction: v_off_ini = 39.643 uV, v_off_fin = 32.509 uV 14:58:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.174 uVs 14:58:58 Integrated Voltage Measurement... 14:59:07 Voltage Offset Correction: v_off_ini = 38.210 uV, v_off_fin = 42.703 uV 14:59:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.976 uVs 14:59:07 Integrated Voltage Measurement... 14:59:16 Voltage Offset Correction: v_off_ini = 31.891 uV, v_off_fin = 41.956 uV 14:59:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -395.359 uVs 14:59:16 Integrated Voltage Measurement... 14:59:25 Voltage Offset Correction: v_off_ini = 39.256 uV, v_off_fin = 27.977 uV 14:59:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.918 uVs 14:59:27 I2Y Average and RMS of Measurements VT = -377.880 +- 6.335 uVs I2Y = -34.765 +- 0.583 uTm^2 14:59:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:36 Integrated Voltage Measurement... 14:59:45 Voltage Offset Correction: v_off_ini = 50.273 uV, v_off_fin = 33.354 uV 14:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.033 uVs 14:59:45 Integrated Voltage Measurement... 14:59:54 Voltage Offset Correction: v_off_ini = 22.688 uV, v_off_fin = 40.226 uV 14:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.247 uVs 14:59:54 Integrated Voltage Measurement... 15:00:03 Voltage Offset Correction: v_off_ini = 45.244 uV, v_off_fin = 31.875 uV 15:00:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.025 uVs 15:00:03 Integrated Voltage Measurement... 15:00:12 Voltage Offset Correction: v_off_ini = 45.362 uV, v_off_fin = 42.107 uV 15:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.671 uVs 15:00:12 Integrated Voltage Measurement... 15:00:21 Voltage Offset Correction: v_off_ini = 50.336 uV, v_off_fin = 48.373 uV 15:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.961 uVs 15:00:21 Integrated Voltage Measurement... 15:00:30 Voltage Offset Correction: v_off_ini = 46.380 uV, v_off_fin = 53.207 uV 15:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.308 uVs 15:00:35 I1X Average and RMS of Measurements VT = -62.541 +- 3.824 uVs I1X = 12.508 +- 0.765 uTm 15:00:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:41 Integrated Voltage Measurement... 15:00:50 Voltage Offset Correction: v_off_ini = 38.164 uV, v_off_fin = 40.333 uV 15:00:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -166.592 uVs 15:00:50 Integrated Voltage Measurement... 15:00:59 Voltage Offset Correction: v_off_ini = 50.982 uV, v_off_fin = 57.362 uV 15:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.125 uVs 15:00:59 Integrated Voltage Measurement... 15:01:08 Voltage Offset Correction: v_off_ini = 49.381 uV, v_off_fin = 26.682 uV 15:01:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.373 uVs 15:01:08 Integrated Voltage Measurement... 15:01:17 Voltage Offset Correction: v_off_ini = 39.200 uV, v_off_fin = 46.797 uV 15:01:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.908 uVs 15:01:17 Integrated Voltage Measurement... 15:01:26 Voltage Offset Correction: v_off_ini = 46.493 uV, v_off_fin = 37.990 uV 15:01:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.779 uVs 15:01:26 Integrated Voltage Measurement... 15:01:35 Voltage Offset Correction: v_off_ini = 45.625 uV, v_off_fin = 46.646 uV 15:01:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 171.478 uVs 15:01:40 I1Y Average and RMS of Measurements VT = -174.209 +- 2.773 uVs I1Y = -34.843 +- 0.555 uTm 15:01:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:47 Integrated Voltage Measurement... 15:01:56 Voltage Offset Correction: v_off_ini = 49.286 uV, v_off_fin = 30.124 uV 15:01:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.446 uVs 15:01:56 Integrated Voltage Measurement... 15:02:05 Voltage Offset Correction: v_off_ini = 38.102 uV, v_off_fin = 50.491 uV 15:02:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.628 uVs 15:02:06 Integrated Voltage Measurement... 15:02:14 Voltage Offset Correction: v_off_ini = 56.601 uV, v_off_fin = 44.130 uV 15:02:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -62.016 uVs 15:02:15 Integrated Voltage Measurement... 15:02:24 Voltage Offset Correction: v_off_ini = 41.412 uV, v_off_fin = 48.074 uV 15:02:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.119 uVs 15:02:24 Integrated Voltage Measurement... 15:02:33 Voltage Offset Correction: v_off_ini = 44.029 uV, v_off_fin = 46.186 uV 15:02:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.371 uVs 15:02:33 Integrated Voltage Measurement... 15:02:42 Voltage Offset Correction: v_off_ini = 59.612 uV, v_off_fin = 50.876 uV 15:02:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.840 uVs 15:02:44 I2X Average and RMS of Measurements VT = -65.737 +- 5.519 uVs I2X = 6.048 +- 0.508 uTm^2 15:02:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:52 Integrated Voltage Measurement... 15:03:01 Voltage Offset Correction: v_off_ini = 52.212 uV, v_off_fin = 42.475 uV 15:03:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.661 uVs 15:03:01 Integrated Voltage Measurement... 15:03:10 Voltage Offset Correction: v_off_ini = 50.559 uV, v_off_fin = 38.210 uV 15:03:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 373.803 uVs 15:03:10 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 38.412 uV, v_off_fin = 38.787 uV 15:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.529 uVs 15:03:19 Integrated Voltage Measurement... 15:03:28 Voltage Offset Correction: v_off_ini = 45.157 uV, v_off_fin = 45.072 uV 15:03:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 385.103 uVs 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 43.489 uV, v_off_fin = 40.636 uV 15:03:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -403.416 uVs 15:03:37 Integrated Voltage Measurement... 15:03:46 Voltage Offset Correction: v_off_ini = 42.261 uV, v_off_fin = 48.785 uV 15:03:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 386.477 uVs 15:03:48 I2Y Average and RMS of Measurements VT = -381.831 +- 9.988 uVs I2Y = -35.130 +- 0.918 uTm^2 15:03:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:03:57 Integrated Voltage Measurement... 15:04:06 Voltage Offset Correction: v_off_ini = 61.081 uV, v_off_fin = 55.124 uV 15:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.111 uVs 15:04:06 Integrated Voltage Measurement... 15:04:15 Voltage Offset Correction: v_off_ini = 47.242 uV, v_off_fin = 54.930 uV 15:04:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.132 uVs 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 57.960 uV, v_off_fin = 59.552 uV 15:04:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.966 uVs 15:04:24 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 55.535 uV, v_off_fin = 52.966 uV 15:04:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.720 uVs 15:04:33 Integrated Voltage Measurement... 15:04:42 Voltage Offset Correction: v_off_ini = 51.200 uV, v_off_fin = 51.086 uV 15:04:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.672 uVs 15:04:42 Integrated Voltage Measurement... 15:04:51 Voltage Offset Correction: v_off_ini = 58.746 uV, v_off_fin = 64.644 uV 15:04:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.854 uVs 15:04:56 I1X Average and RMS of Measurements VT = -69.243 +- 1.542 uVs I1X = 13.849 +- 0.308 uTm 15:04:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:05:02 Integrated Voltage Measurement... 15:05:11 Voltage Offset Correction: v_off_ini = 64.736 uV, v_off_fin = 63.389 uV 15:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.104 uVs 15:05:11 Integrated Voltage Measurement... 15:05:20 Voltage Offset Correction: v_off_ini = 59.475 uV, v_off_fin = 66.086 uV 15:05:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.468 uVs 15:05:21 Integrated Voltage Measurement... 15:05:29 Voltage Offset Correction: v_off_ini = 57.935 uV, v_off_fin = 44.287 uV 15:05:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.701 uVs 15:05:30 Integrated Voltage Measurement... 15:05:38 Voltage Offset Correction: v_off_ini = 52.238 uV, v_off_fin = 59.859 uV 15:05:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.790 uVs 15:05:39 Integrated Voltage Measurement... 15:05:47 Voltage Offset Correction: v_off_ini = 60.183 uV, v_off_fin = 44.829 uV 15:05:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.340 uVs 15:05:47 Integrated Voltage Measurement... 15:05:56 Voltage Offset Correction: v_off_ini = 61.731 uV, v_off_fin = 68.993 uV 15:05:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.452 uVs 15:06:01 I1Y Average and RMS of Measurements VT = -184.476 +- 3.126 uVs I1Y = -36.895 +- 0.625 uTm 15:06:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:06:08 Integrated Voltage Measurement... 15:06:17 Voltage Offset Correction: v_off_ini = 53.561 uV, v_off_fin = 51.910 uV 15:06:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.362 uVs 15:06:17 Integrated Voltage Measurement... 15:06:26 Voltage Offset Correction: v_off_ini = 62.884 uV, v_off_fin = 63.514 uV 15:06:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.054 uVs 15:06:27 Integrated Voltage Measurement... 15:06:36 Voltage Offset Correction: v_off_ini = 57.859 uV, v_off_fin = 57.896 uV 15:06:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.302 uVs 15:06:36 Integrated Voltage Measurement... 15:06:45 Voltage Offset Correction: v_off_ini = 75.172 uV, v_off_fin = 65.174 uV 15:06:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.450 uVs 15:06:45 Integrated Voltage Measurement... 15:06:54 Voltage Offset Correction: v_off_ini = 59.435 uV, v_off_fin = 48.779 uV 15:06:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.407 uVs 15:06:54 Integrated Voltage Measurement... 15:07:03 Voltage Offset Correction: v_off_ini = 62.291 uV, v_off_fin = 59.321 uV 15:07:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.955 uVs 15:07:05 I2X Average and RMS of Measurements VT = -70.255 +- 5.053 uVs I2X = 6.464 +- 0.465 uTm^2 15:07:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:07:13 Integrated Voltage Measurement... 15:07:22 Voltage Offset Correction: v_off_ini = 54.269 uV, v_off_fin = 48.887 uV 15:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.785 uVs 15:07:22 Integrated Voltage Measurement... 15:07:31 Voltage Offset Correction: v_off_ini = 65.912 uV, v_off_fin = 56.389 uV 15:07:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.263 uVs 15:07:31 Integrated Voltage Measurement... 15:07:40 Voltage Offset Correction: v_off_ini = 49.258 uV, v_off_fin = 56.155 uV 15:07:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.148 uVs 15:07:40 Integrated Voltage Measurement... 15:07:49 Voltage Offset Correction: v_off_ini = 50.937 uV, v_off_fin = 54.045 uV 15:07:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.942 uVs 15:07:49 Integrated Voltage Measurement... 15:07:58 Voltage Offset Correction: v_off_ini = 54.659 uV, v_off_fin = 59.488 uV 15:07:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -386.269 uVs 15:07:58 Integrated Voltage Measurement... 15:08:07 Voltage Offset Correction: v_off_ini = 39.132 uV, v_off_fin = 51.777 uV 15:08:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.751 uVs 15:08:09 I2Y Average and RMS of Measurements VT = -383.193 +- 5.168 uVs I2Y = -35.254 +- 0.475 uTm^2 15:08:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:08:18 Integrated Voltage Measurement... 15:08:27 Voltage Offset Correction: v_off_ini = 48.875 uV, v_off_fin = 44.447 uV 15:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.980 uVs 15:08:27 Integrated Voltage Measurement... 15:08:36 Voltage Offset Correction: v_off_ini = 38.203 uV, v_off_fin = 30.378 uV 15:08:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.562 uVs 15:08:36 Integrated Voltage Measurement... 15:08:45 Voltage Offset Correction: v_off_ini = 45.219 uV, v_off_fin = 47.094 uV 15:08:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.530 uVs 15:08:45 Integrated Voltage Measurement... 15:08:54 Voltage Offset Correction: v_off_ini = 58.107 uV, v_off_fin = 62.705 uV 15:08:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.726 uVs 15:08:55 Integrated Voltage Measurement... 15:09:03 Voltage Offset Correction: v_off_ini = 55.112 uV, v_off_fin = 46.780 uV 15:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.577 uVs 15:09:04 Integrated Voltage Measurement... 15:09:12 Voltage Offset Correction: v_off_ini = 50.463 uV, v_off_fin = 55.257 uV 15:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.839 uVs 15:09:17 I1X Average and RMS of Measurements VT = -79.535 +- 1.207 uVs I1X = 15.907 +- 0.241 uTm 15:09:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:09:24 Integrated Voltage Measurement... 15:09:32 Voltage Offset Correction: v_off_ini = 54.657 uV, v_off_fin = 41.077 uV 15:09:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.823 uVs 15:09:33 Integrated Voltage Measurement... 15:09:41 Voltage Offset Correction: v_off_ini = 35.646 uV, v_off_fin = 51.288 uV 15:09:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.231 uVs 15:09:42 Integrated Voltage Measurement... 15:09:50 Voltage Offset Correction: v_off_ini = 47.865 uV, v_off_fin = 40.230 uV 15:09:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.075 uVs 15:09:51 Integrated Voltage Measurement... 15:09:59 Voltage Offset Correction: v_off_ini = 46.036 uV, v_off_fin = 48.667 uV 15:09:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.915 uVs 15:10:00 Integrated Voltage Measurement... 15:10:08 Voltage Offset Correction: v_off_ini = 34.377 uV, v_off_fin = 33.905 uV 15:10:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.499 uVs 15:10:09 Integrated Voltage Measurement... 15:10:17 Voltage Offset Correction: v_off_ini = 33.731 uV, v_off_fin = 55.664 uV 15:10:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.678 uVs 15:10:22 I1Y Average and RMS of Measurements VT = -174.370 +- 4.604 uVs I1Y = -34.874 +- 0.921 uTm 15:10:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:10:29 Integrated Voltage Measurement... 15:10:38 Voltage Offset Correction: v_off_ini = 25.981 uV, v_off_fin = 26.412 uV 15:10:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.110 uVs 15:10:39 Integrated Voltage Measurement... 15:10:47 Voltage Offset Correction: v_off_ini = 33.433 uV, v_off_fin = 39.382 uV 15:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.428 uVs 15:10:48 Integrated Voltage Measurement... 15:10:57 Voltage Offset Correction: v_off_ini = 36.631 uV, v_off_fin = 26.184 uV 15:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.893 uVs 15:10:57 Integrated Voltage Measurement... 15:11:06 Voltage Offset Correction: v_off_ini = 22.497 uV, v_off_fin = 44.687 uV 15:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.743 uVs 15:11:06 Integrated Voltage Measurement... 15:11:15 Voltage Offset Correction: v_off_ini = 42.344 uV, v_off_fin = 27.220 uV 15:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.523 uVs 15:11:15 Integrated Voltage Measurement... 15:11:24 Voltage Offset Correction: v_off_ini = 40.891 uV, v_off_fin = 39.396 uV 15:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.072 uVs 15:11:26 I2X Average and RMS of Measurements VT = -84.461 +- 7.945 uVs I2X = 7.770 +- 0.731 uTm^2 15:11:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:11:34 Integrated Voltage Measurement... 15:11:43 Voltage Offset Correction: v_off_ini = 36.512 uV, v_off_fin = 22.014 uV 15:11:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -375.213 uVs 15:11:43 Integrated Voltage Measurement... 15:11:52 Voltage Offset Correction: v_off_ini = 21.001 uV, v_off_fin = 3.581 uV 15:11:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.897 uVs 15:11:52 Integrated Voltage Measurement... 15:12:01 Voltage Offset Correction: v_off_ini = 16.505 uV, v_off_fin = 2.030 uV 15:12:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.370 uVs 15:12:01 Integrated Voltage Measurement... 15:12:10 Voltage Offset Correction: v_off_ini = 3.312 uV, v_off_fin = 7.045 uV 15:12:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.259 uVs 15:12:10 Integrated Voltage Measurement... 15:12:19 Voltage Offset Correction: v_off_ini = 0.194 uV, v_off_fin = 3.503 uV 15:12:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.807 uVs 15:12:19 Integrated Voltage Measurement... 15:12:28 Voltage Offset Correction: v_off_ini = -1.752 uV, v_off_fin = -2.170 uV 15:12:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.984 uVs 15:12:30 I2Y Average and RMS of Measurements VT = -372.422 +- 11.880 uVs I2Y = -34.263 +- 1.093 uTm^2 15:12:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:12:42 Integrated Voltage Measurement... 15:12:51 Voltage Offset Correction: v_off_ini = 8.811 uV, v_off_fin = -1.361 uV 15:12:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.064 uVs 15:12:52 Integrated Voltage Measurement... 15:13:00 Voltage Offset Correction: v_off_ini = 14.365 uV, v_off_fin = -6.780 uV 15:13:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.161 uVs 15:13:01 Integrated Voltage Measurement... 15:13:10 Voltage Offset Correction: v_off_ini = -3.002 uV, v_off_fin = -10.331 uV 15:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.951 uVs 15:13:10 Integrated Voltage Measurement... 15:13:19 Voltage Offset Correction: v_off_ini = -13.959 uV, v_off_fin = 0.586 uV 15:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.350 uVs 15:13:19 Integrated Voltage Measurement... 15:13:28 Voltage Offset Correction: v_off_ini = 5.744 uV, v_off_fin = -9.173 uV 15:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.040 uVs 15:13:28 Integrated Voltage Measurement... 15:13:37 Voltage Offset Correction: v_off_ini = -16.088 uV, v_off_fin = -6.119 uV 15:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.815 uVs 15:13:41 I1X Average and RMS of Measurements VT = -66.397 +- 5.670 uVs I1X = 13.280 +- 1.134 uTm 15:13:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:13:48 Integrated Voltage Measurement... 15:13:57 Voltage Offset Correction: v_off_ini = -10.851 uV, v_off_fin = -13.682 uV 15:13:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.917 uVs 15:13:57 Integrated Voltage Measurement... 15:14:06 Voltage Offset Correction: v_off_ini = -15.417 uV, v_off_fin = -0.557 uV 15:14:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.453 uVs 15:14:06 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = -7.415 uV, v_off_fin = -16.711 uV 15:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.261 uVs 15:14:15 Integrated Voltage Measurement... 15:14:24 Voltage Offset Correction: v_off_ini = -11.377 uV, v_off_fin = 1.644 uV 15:14:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.929 uVs 15:14:24 Integrated Voltage Measurement... 15:14:33 Voltage Offset Correction: v_off_ini = -5.405 uV, v_off_fin = -1.356 uV 15:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.621 uVs 15:14:33 Integrated Voltage Measurement... 15:14:42 Voltage Offset Correction: v_off_ini = 15.622 uV, v_off_fin = 19.519 uV 15:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.980 uVs 15:14:46 I1Y Average and RMS of Measurements VT = -172.360 +- 1.864 uVs I1Y = -34.473 +- 0.373 uTm 15:14:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:14:51 Integrated Voltage Measurement... 15:15:00 Voltage Offset Correction: v_off_ini = 0.021 uV, v_off_fin = -2.358 uV 15:15:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.142 uVs 15:15:00 Integrated Voltage Measurement... 15:15:09 Voltage Offset Correction: v_off_ini = 2.367 uV, v_off_fin = 9.901 uV 15:15:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.389 uVs 15:15:09 Integrated Voltage Measurement... 15:15:18 Voltage Offset Correction: v_off_ini = 9.106 uV, v_off_fin = 4.934 uV 15:15:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.360 uVs 15:15:18 Integrated Voltage Measurement... 15:15:27 Voltage Offset Correction: v_off_ini = 28.737 uV, v_off_fin = 38.879 uV 15:15:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.180 uVs 15:15:27 Integrated Voltage Measurement... 15:15:36 Voltage Offset Correction: v_off_ini = 18.856 uV, v_off_fin = 18.276 uV 15:15:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -54.701 uVs 15:15:36 Integrated Voltage Measurement... 15:15:45 Voltage Offset Correction: v_off_ini = 13.692 uV, v_off_fin = 29.631 uV 15:15:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.474 uVs 15:15:48 I2X Average and RMS of Measurements VT = -57.208 +- 5.267 uVs I2X = 5.263 +- 0.485 uTm^2 15:15:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 3.995 uV, v_off_fin = 7.630 uV 15:16:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.995 uVs 15:16:02 Integrated Voltage Measurement... 15:16:11 Voltage Offset Correction: v_off_ini = 8.828 uV, v_off_fin = -4.397 uV 15:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.230 uVs 15:16:11 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 11.175 uV, v_off_fin = 5.090 uV 15:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.261 uVs 15:16:20 Integrated Voltage Measurement... 15:16:29 Voltage Offset Correction: v_off_ini = 3.543 uV, v_off_fin = 1.587 uV 15:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.790 uVs 15:16:29 Integrated Voltage Measurement... 15:16:38 Voltage Offset Correction: v_off_ini = 8.938 uV, v_off_fin = 5.299 uV 15:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.611 uVs 15:16:38 Integrated Voltage Measurement... 15:16:47 Voltage Offset Correction: v_off_ini = 12.141 uV, v_off_fin = 3.836 uV 15:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.749 uVs 15:16:49 I2Y Average and RMS of Measurements VT = -366.939 +- 4.448 uVs I2Y = -33.758 +- 0.409 uTm^2 15:16:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:16:58 Integrated Voltage Measurement... 15:17:07 Voltage Offset Correction: v_off_ini = -4.089 uV, v_off_fin = 5.678 uV 15:17:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.132 uVs 15:17:07 Integrated Voltage Measurement... 15:17:16 Voltage Offset Correction: v_off_ini = 8.398 uV, v_off_fin = 13.278 uV 15:17:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 68.127 uVs 15:17:16 Integrated Voltage Measurement... 15:17:25 Voltage Offset Correction: v_off_ini = -0.438 uV, v_off_fin = 3.958 uV 15:17:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.343 uVs 15:17:25 Integrated Voltage Measurement... 15:17:34 Voltage Offset Correction: v_off_ini = 6.219 uV, v_off_fin = 6.707 uV 15:17:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.708 uVs 15:17:34 Integrated Voltage Measurement... 15:17:43 Voltage Offset Correction: v_off_ini = 11.795 uV, v_off_fin = 22.547 uV 15:17:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.574 uVs 15:17:43 Integrated Voltage Measurement... 15:17:52 Voltage Offset Correction: v_off_ini = 15.112 uV, v_off_fin = 9.979 uV 15:17:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.072 uVs 15:17:56 I1X Average and RMS of Measurements VT = -66.492 +- 6.426 uVs I1X = 13.299 +- 1.286 uTm 15:17:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:18:03 Integrated Voltage Measurement... 15:18:12 Voltage Offset Correction: v_off_ini = 27.792 uV, v_off_fin = 14.895 uV 15:18:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.530 uVs 15:18:12 Integrated Voltage Measurement... 15:18:21 Voltage Offset Correction: v_off_ini = 15.976 uV, v_off_fin = 18.317 uV 15:18:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.171 uVs 15:18:21 Integrated Voltage Measurement... 15:18:30 Voltage Offset Correction: v_off_ini = 30.428 uV, v_off_fin = 12.208 uV 15:18:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.280 uVs 15:18:30 Integrated Voltage Measurement... 15:18:39 Voltage Offset Correction: v_off_ini = 30.456 uV, v_off_fin = 35.752 uV 15:18:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.403 uVs 15:18:39 Integrated Voltage Measurement... 15:18:48 Voltage Offset Correction: v_off_ini = 36.606 uV, v_off_fin = 25.810 uV 15:18:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.919 uVs 15:18:48 Integrated Voltage Measurement... 15:18:57 Voltage Offset Correction: v_off_ini = 45.145 uV, v_off_fin = 35.930 uV 15:18:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.203 uVs 15:19:01 I1Y Average and RMS of Measurements VT = -183.918 +- 2.131 uVs I1Y = -36.784 +- 0.426 uTm 15:19:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:19:06 Integrated Voltage Measurement... 15:19:15 Voltage Offset Correction: v_off_ini = 25.913 uV, v_off_fin = 33.600 uV 15:19:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.726 uVs 15:19:15 Integrated Voltage Measurement... 15:19:24 Voltage Offset Correction: v_off_ini = 47.958 uV, v_off_fin = 58.417 uV 15:19:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.946 uVs 15:19:24 Integrated Voltage Measurement... 15:19:33 Voltage Offset Correction: v_off_ini = 53.974 uV, v_off_fin = 30.557 uV 15:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.203 uVs 15:19:33 Integrated Voltage Measurement... 15:19:42 Voltage Offset Correction: v_off_ini = 25.123 uV, v_off_fin = 29.594 uV 15:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.118 uVs 15:19:42 Integrated Voltage Measurement... 15:19:51 Voltage Offset Correction: v_off_ini = 40.208 uV, v_off_fin = 10.441 uV 15:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.955 uVs 15:19:52 Integrated Voltage Measurement... 15:20:00 Voltage Offset Correction: v_off_ini = 25.551 uV, v_off_fin = 21.876 uV 15:20:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.260 uVs 15:20:03 I2X Average and RMS of Measurements VT = -69.701 +- 8.098 uVs I2X = 6.413 +- 0.745 uTm^2 15:20:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = 17.585 uV, v_off_fin = 27.321 uV 15:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.307 uVs 15:20:17 Integrated Voltage Measurement... 15:20:26 Voltage Offset Correction: v_off_ini = 20.256 uV, v_off_fin = 31.064 uV 15:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.200 uVs 15:20:26 Integrated Voltage Measurement... 15:20:35 Voltage Offset Correction: v_off_ini = 14.257 uV, v_off_fin = 14.209 uV 15:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.816 uVs 15:20:35 Integrated Voltage Measurement... 15:20:44 Voltage Offset Correction: v_off_ini = 26.235 uV, v_off_fin = 26.853 uV 15:20:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.072 uVs 15:20:44 Integrated Voltage Measurement... 15:20:53 Voltage Offset Correction: v_off_ini = 20.634 uV, v_off_fin = 22.722 uV 15:20:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.688 uVs 15:20:53 Integrated Voltage Measurement... 15:21:02 Voltage Offset Correction: v_off_ini = 21.814 uV, v_off_fin = 45.253 uV 15:21:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 391.231 uVs 15:21:05 I2Y Average and RMS of Measurements VT = -377.552 +- 6.761 uVs I2Y = -34.735 +- 0.623 uTm^2 15:21:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:13 Integrated Voltage Measurement... 15:21:22 Voltage Offset Correction: v_off_ini = 26.527 uV, v_off_fin = 24.653 uV 15:21:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.987 uVs 15:21:22 Integrated Voltage Measurement... 15:21:31 Voltage Offset Correction: v_off_ini = 44.232 uV, v_off_fin = 27.538 uV 15:21:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.344 uVs 15:21:31 Integrated Voltage Measurement... 15:21:40 Voltage Offset Correction: v_off_ini = 23.036 uV, v_off_fin = 13.156 uV 15:21:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.643 uVs 15:21:40 Integrated Voltage Measurement... 15:21:49 Voltage Offset Correction: v_off_ini = 19.706 uV, v_off_fin = 23.694 uV 15:21:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.087 uVs 15:21:49 Integrated Voltage Measurement... 15:21:58 Voltage Offset Correction: v_off_ini = 30.521 uV, v_off_fin = 19.644 uV 15:21:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.954 uVs 15:21:58 Integrated Voltage Measurement... 15:22:07 Voltage Offset Correction: v_off_ini = 12.460 uV, v_off_fin = 17.980 uV 15:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.775 uVs 15:22:11 I1X Average and RMS of Measurements VT = -74.298 +- 5.817 uVs I1X = 14.860 +- 1.163 uTm 15:22:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:18 Integrated Voltage Measurement... 15:22:27 Voltage Offset Correction: v_off_ini = 10.239 uV, v_off_fin = 10.548 uV 15:22:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.046 uVs 15:22:27 Integrated Voltage Measurement... 15:22:36 Voltage Offset Correction: v_off_ini = 12.126 uV, v_off_fin = 25.348 uV 15:22:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 168.671 uVs 15:22:36 Integrated Voltage Measurement... 15:22:45 Voltage Offset Correction: v_off_ini = 11.852 uV, v_off_fin = -2.711 uV 15:22:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.315 uVs 15:22:45 Integrated Voltage Measurement... 15:22:54 Voltage Offset Correction: v_off_ini = 5.457 uV, v_off_fin = 24.384 uV 15:22:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.827 uVs 15:22:54 Integrated Voltage Measurement... 15:23:03 Voltage Offset Correction: v_off_ini = 11.516 uV, v_off_fin = 6.455 uV 15:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.455 uVs 15:23:03 Integrated Voltage Measurement... 15:23:12 Voltage Offset Correction: v_off_ini = 15.296 uV, v_off_fin = 16.564 uV 15:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.456 uVs 15:23:16 I1Y Average and RMS of Measurements VT = -178.795 +- 4.601 uVs I1Y = -35.760 +- 0.920 uTm 15:23:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:22 Integrated Voltage Measurement... 15:23:30 Voltage Offset Correction: v_off_ini = 21.351 uV, v_off_fin = 7.050 uV 15:23:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.107 uVs 15:23:31 Integrated Voltage Measurement... 15:23:40 Voltage Offset Correction: v_off_ini = 22.361 uV, v_off_fin = 21.955 uV 15:23:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.496 uVs 15:23:40 Integrated Voltage Measurement... 15:23:49 Voltage Offset Correction: v_off_ini = 14.079 uV, v_off_fin = 16.685 uV 15:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.200 uVs 15:23:49 Integrated Voltage Measurement... 15:23:58 Voltage Offset Correction: v_off_ini = 16.638 uV, v_off_fin = 21.734 uV 15:23:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 55.758 uVs 15:23:58 Integrated Voltage Measurement... 15:24:07 Voltage Offset Correction: v_off_ini = -10.230 uV, v_off_fin = 3.417 uV 15:24:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -52.944 uVs 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = 19.109 uV, v_off_fin = 14.210 uV 15:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.192 uVs 15:24:18 I2X Average and RMS of Measurements VT = -59.783 +- 8.852 uVs I2X = 5.500 +- 0.814 uTm^2 15:24:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:23 Integrated Voltage Measurement... 15:24:32 Voltage Offset Correction: v_off_ini = 6.039 uV, v_off_fin = 23.552 uV 15:24:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.069 uVs 15:24:32 Integrated Voltage Measurement... 15:24:41 Voltage Offset Correction: v_off_ini = 18.847 uV, v_off_fin = 25.118 uV 15:24:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.695 uVs 15:24:41 Integrated Voltage Measurement... 15:24:50 Voltage Offset Correction: v_off_ini = 21.476 uV, v_off_fin = 14.066 uV 15:24:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.374 uVs 15:24:50 Integrated Voltage Measurement... 15:24:59 Voltage Offset Correction: v_off_ini = 6.835 uV, v_off_fin = 12.601 uV 15:24:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.301 uVs 15:25:00 Integrated Voltage Measurement... 15:25:08 Voltage Offset Correction: v_off_ini = 13.477 uV, v_off_fin = -1.486 uV 15:25:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.999 uVs 15:25:09 Integrated Voltage Measurement... 15:25:18 Voltage Offset Correction: v_off_ini = 17.550 uV, v_off_fin = 12.160 uV 15:25:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.692 uVs 15:25:20 I2Y Average and RMS of Measurements VT = -379.188 +- 8.439 uVs I2Y = -34.885 +- 0.776 uTm^2 15:25:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:25:28 Integrated Voltage Measurement... 15:25:37 Voltage Offset Correction: v_off_ini = -4.983 uV, v_off_fin = -12.677 uV 15:25:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.608 uVs 15:25:37 Integrated Voltage Measurement... 15:25:46 Voltage Offset Correction: v_off_ini = -22.026 uV, v_off_fin = 6.873 uV 15:25:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.626 uVs 15:25:46 Integrated Voltage Measurement... 15:25:55 Voltage Offset Correction: v_off_ini = -22.865 uV, v_off_fin = -20.033 uV 15:25:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.231 uVs 15:25:55 Integrated Voltage Measurement... 15:26:04 Voltage Offset Correction: v_off_ini = -6.022 uV, v_off_fin = -0.259 uV 15:26:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.149 uVs 15:26:04 Integrated Voltage Measurement... 15:26:13 Voltage Offset Correction: v_off_ini = 2.046 uV, v_off_fin = -6.403 uV 15:26:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.919 uVs 15:26:13 Integrated Voltage Measurement... 15:26:22 Voltage Offset Correction: v_off_ini = -1.482 uV, v_off_fin = -2.666 uV 15:26:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.694 uVs 15:26:27 I1X Average and RMS of Measurements VT = -61.705 +- 17.337 uVs I1X = 12.341 +- 3.468 uTm 15:26:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:26:33 Integrated Voltage Measurement... 15:26:42 Voltage Offset Correction: v_off_ini = -10.150 uV, v_off_fin = -11.285 uV 15:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.727 uVs 15:26:42 Integrated Voltage Measurement... 15:26:51 Voltage Offset Correction: v_off_ini = 2.844 uV, v_off_fin = -3.540 uV 15:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.599 uVs 15:26:52 Integrated Voltage Measurement... 15:27:00 Voltage Offset Correction: v_off_ini = -16.119 uV, v_off_fin = -17.970 uV 15:27:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.569 uVs 15:27:01 Integrated Voltage Measurement... 15:27:09 Voltage Offset Correction: v_off_ini = -5.675 uV, v_off_fin = -1.118 uV 15:27:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 181.701 uVs 15:27:10 Integrated Voltage Measurement... 15:27:18 Voltage Offset Correction: v_off_ini = -0.583 uV, v_off_fin = -11.245 uV 15:27:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -187.014 uVs 15:27:19 Integrated Voltage Measurement... 15:27:27 Voltage Offset Correction: v_off_ini = -7.138 uV, v_off_fin = 16.025 uV 15:27:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.330 uVs 15:27:32 I1Y Average and RMS of Measurements VT = -185.490 +- 0.863 uVs I1Y = -37.094 +- 0.172 uTm 15:27:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:27:37 Integrated Voltage Measurement... 15:27:46 Voltage Offset Correction: v_off_ini = -6.930 uV, v_off_fin = -0.212 uV 15:27:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.331 uVs 15:27:46 Integrated Voltage Measurement... 15:27:55 Voltage Offset Correction: v_off_ini = -1.030 uV, v_off_fin = 8.043 uV 15:27:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.632 uVs 15:27:55 Integrated Voltage Measurement... 15:28:04 Voltage Offset Correction: v_off_ini = 0.665 uV, v_off_fin = -0.658 uV 15:28:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.363 uVs 15:28:04 Integrated Voltage Measurement... 15:28:13 Voltage Offset Correction: v_off_ini = 6.512 uV, v_off_fin = 19.058 uV 15:28:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.657 uVs 15:28:13 Integrated Voltage Measurement... 15:28:22 Voltage Offset Correction: v_off_ini = 4.206 uV, v_off_fin = 1.327 uV 15:28:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.188 uVs 15:28:22 Integrated Voltage Measurement... 15:28:31 Voltage Offset Correction: v_off_ini = -0.344 uV, v_off_fin = 27.901 uV 15:28:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.252 uVs 15:28:33 I2X Average and RMS of Measurements VT = -62.570 +- 4.729 uVs I2X = 5.757 +- 0.435 uTm^2 15:28:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:28:39 Integrated Voltage Measurement... 15:28:48 Voltage Offset Correction: v_off_ini = 20.667 uV, v_off_fin = 18.886 uV 15:28:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.448 uVs 15:28:48 Integrated Voltage Measurement... 15:28:57 Voltage Offset Correction: v_off_ini = 8.967 uV, v_off_fin = 10.732 uV 15:28:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.640 uVs 15:28:57 Integrated Voltage Measurement... 15:29:06 Voltage Offset Correction: v_off_ini = 11.909 uV, v_off_fin = 15.752 uV 15:29:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.651 uVs 15:29:06 Integrated Voltage Measurement... 15:29:15 Voltage Offset Correction: v_off_ini = 12.086 uV, v_off_fin = 20.652 uV 15:29:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.924 uVs 15:29:15 Integrated Voltage Measurement... 15:29:24 Voltage Offset Correction: v_off_ini = 22.202 uV, v_off_fin = 12.115 uV 15:29:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -392.658 uVs 15:29:24 Integrated Voltage Measurement... 15:29:33 Voltage Offset Correction: v_off_ini = 11.799 uV, v_off_fin = 17.009 uV 15:29:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 393.458 uVs 15:29:35 I2Y Average and RMS of Measurements VT = -384.630 +- 6.064 uVs I2Y = -35.387 +- 0.559 uTm^2 15:29:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:29:44 Integrated Voltage Measurement... 15:29:53 Voltage Offset Correction: v_off_ini = -3.619 uV, v_off_fin = -12.998 uV 15:29:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.585 uVs 15:29:53 Integrated Voltage Measurement... 15:30:02 Voltage Offset Correction: v_off_ini = 6.888 uV, v_off_fin = 14.572 uV 15:30:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.029 uVs 15:30:02 Integrated Voltage Measurement... 15:30:11 Voltage Offset Correction: v_off_ini = 4.158 uV, v_off_fin = 1.727 uV 15:30:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.054 uVs 15:30:11 Integrated Voltage Measurement... 15:30:20 Voltage Offset Correction: v_off_ini = 8.499 uV, v_off_fin = 13.917 uV 15:30:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.404 uVs 15:30:20 Integrated Voltage Measurement... 15:30:29 Voltage Offset Correction: v_off_ini = 12.734 uV, v_off_fin = 11.139 uV 15:30:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.434 uVs 15:30:29 Integrated Voltage Measurement... 15:30:38 Voltage Offset Correction: v_off_ini = 8.724 uV, v_off_fin = 33.578 uV 15:30:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.627 uVs 15:30:42 I1X Average and RMS of Measurements VT = -61.356 +- 6.928 uVs I1X = 12.271 +- 1.385 uTm 15:30:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:30:49 Integrated Voltage Measurement... 15:30:58 Voltage Offset Correction: v_off_ini = 14.623 uV, v_off_fin = 2.286 uV 15:30:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.747 uVs 15:30:58 Integrated Voltage Measurement... 15:31:07 Voltage Offset Correction: v_off_ini = 25.702 uV, v_off_fin = 34.505 uV 15:31:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.333 uVs 15:31:07 Integrated Voltage Measurement... 15:31:16 Voltage Offset Correction: v_off_ini = 10.484 uV, v_off_fin = -0.844 uV 15:31:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -186.116 uVs 15:31:16 Integrated Voltage Measurement... 15:31:25 Voltage Offset Correction: v_off_ini = 13.523 uV, v_off_fin = 21.337 uV 15:31:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 160.982 uVs 15:31:25 Integrated Voltage Measurement... 15:31:34 Voltage Offset Correction: v_off_ini = 4.482 uV, v_off_fin = -5.653 uV 15:31:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.523 uVs 15:31:34 Integrated Voltage Measurement... 15:31:43 Voltage Offset Correction: v_off_ini = 0.168 uV, v_off_fin = 15.550 uV 15:31:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.470 uVs 15:31:47 I1Y Average and RMS of Measurements VT = -179.362 +- 4.158 uVs I1Y = -35.870 +- 0.834 uTm 15:31:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:31:52 Integrated Voltage Measurement... 15:32:01 Voltage Offset Correction: v_off_ini = -6.578 uV, v_off_fin = -17.253 uV 15:32:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.448 uVs 15:32:01 Integrated Voltage Measurement... 15:32:10 Voltage Offset Correction: v_off_ini = 3.497 uV, v_off_fin = 1.237 uV 15:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.470 uVs 15:32:10 Integrated Voltage Measurement... 15:32:19 Voltage Offset Correction: v_off_ini = -8.191 uV, v_off_fin = -20.066 uV 15:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.806 uVs 15:32:19 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = -7.187 uV, v_off_fin = -3.108 uV 15:32:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.231 uVs 15:32:28 Integrated Voltage Measurement... 15:32:37 Voltage Offset Correction: v_off_ini = -6.899 uV, v_off_fin = -5.122 uV 15:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.029 uVs 15:32:37 Integrated Voltage Measurement... 15:32:46 Voltage Offset Correction: v_off_ini = -4.967 uV, v_off_fin = -0.664 uV 15:32:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.930 uVs 15:32:49 I2X Average and RMS of Measurements VT = -59.986 +- 10.299 uVs I2X = 5.519 +- 0.947 uTm^2 15:32:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:32:54 Integrated Voltage Measurement... 15:33:03 Voltage Offset Correction: v_off_ini = -5.698 uV, v_off_fin = -6.476 uV 15:33:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.176 uVs 15:33:03 Integrated Voltage Measurement... 15:33:12 Voltage Offset Correction: v_off_ini = -9.816 uV, v_off_fin = 1.873 uV 15:33:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.998 uVs 15:33:12 Integrated Voltage Measurement... 15:33:21 Voltage Offset Correction: v_off_ini = -0.220 uV, v_off_fin = 3.350 uV 15:33:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -391.339 uVs 15:33:21 Integrated Voltage Measurement... 15:33:30 Voltage Offset Correction: v_off_ini = -5.391 uV, v_off_fin = -7.520 uV 15:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.487 uVs 15:33:30 Integrated Voltage Measurement... 15:33:39 Voltage Offset Correction: v_off_ini = -5.270 uV, v_off_fin = -1.699 uV 15:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -381.773 uVs 15:33:39 Integrated Voltage Measurement... 15:33:48 Voltage Offset Correction: v_off_ini = -24.190 uV, v_off_fin = -20.754 uV 15:33:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 392.953 uVs 15:33:51 I2Y Average and RMS of Measurements VT = -388.621 +- 1.744 uVs I2Y = -35.753 +- 0.160 uTm^2 15:34:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:34:12 Integrated Voltage Measurement... 15:34:21 Voltage Offset Correction: v_off_ini = -6.676 uV, v_off_fin = -14.559 uV 15:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -50.834 uVs 15:34:21 Integrated Voltage Measurement... 15:34:30 Voltage Offset Correction: v_off_ini = -9.572 uV, v_off_fin = -16.446 uV 15:34:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.463 uVs 15:34:30 Integrated Voltage Measurement... 15:34:39 Voltage Offset Correction: v_off_ini = -17.334 uV, v_off_fin = -30.587 uV 15:34:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.998 uVs 15:34:39 Integrated Voltage Measurement... 15:34:48 Voltage Offset Correction: v_off_ini = -19.834 uV, v_off_fin = -29.469 uV 15:34:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.553 uVs 15:34:48 Integrated Voltage Measurement... 15:34:57 Voltage Offset Correction: v_off_ini = -29.761 uV, v_off_fin = -28.682 uV 15:34:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.559 uVs 15:34:57 Integrated Voltage Measurement... 15:35:06 Voltage Offset Correction: v_off_ini = -29.055 uV, v_off_fin = -20.215 uV 15:35:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.722 uVs 15:35:10 I1X Average and RMS of Measurements VT = -50.855 +- 1.208 uVs I1X = 10.171 +- 0.241 uTm 15:35:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:35:17 Integrated Voltage Measurement... 15:35:26 Voltage Offset Correction: v_off_ini = -20.295 uV, v_off_fin = -24.777 uV 15:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.836 uVs 15:35:26 Integrated Voltage Measurement... 15:35:35 Voltage Offset Correction: v_off_ini = -10.103 uV, v_off_fin = -14.019 uV 15:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.861 uVs 15:35:35 Integrated Voltage Measurement... 15:35:44 Voltage Offset Correction: v_off_ini = -15.698 uV, v_off_fin = -25.602 uV 15:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.959 uVs 15:35:44 Integrated Voltage Measurement... 15:35:53 Voltage Offset Correction: v_off_ini = -16.152 uV, v_off_fin = 2.195 uV 15:35:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.002 uVs 15:35:53 Integrated Voltage Measurement... 15:36:02 Voltage Offset Correction: v_off_ini = -10.866 uV, v_off_fin = -16.067 uV 15:36:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.930 uVs 15:36:02 Integrated Voltage Measurement... 15:36:11 Voltage Offset Correction: v_off_ini = -18.284 uV, v_off_fin = -0.742 uV 15:36:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.692 uVs 15:36:15 I1Y Average and RMS of Measurements VT = -165.213 +- 4.872 uVs I1Y = -33.043 +- 0.974 uTm 15:36:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:36:23 Integrated Voltage Measurement... 15:36:32 Voltage Offset Correction: v_off_ini = -16.356 uV, v_off_fin = -17.399 uV 15:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.909 uVs 15:36:32 Integrated Voltage Measurement... 15:36:41 Voltage Offset Correction: v_off_ini = -7.373 uV, v_off_fin = 4.724 uV 15:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.439 uVs 15:36:41 Integrated Voltage Measurement... 15:36:50 Voltage Offset Correction: v_off_ini = -10.746 uV, v_off_fin = -27.027 uV 15:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.101 uVs 15:36:50 Integrated Voltage Measurement... 15:36:59 Voltage Offset Correction: v_off_ini = -14.314 uV, v_off_fin = -2.336 uV 15:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.654 uVs 15:36:59 Integrated Voltage Measurement... 15:37:08 Voltage Offset Correction: v_off_ini = -25.010 uV, v_off_fin = -10.386 uV 15:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.930 uVs 15:37:08 Integrated Voltage Measurement... 15:37:17 Voltage Offset Correction: v_off_ini = -10.485 uV, v_off_fin = -25.545 uV 15:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.729 uVs 15:37:19 I2X Average and RMS of Measurements VT = -36.127 +- 5.541 uVs I2X = 3.324 +- 0.510 uTm^2 15:37:24 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:37:27 Integrated Voltage Measurement... 15:37:36 Voltage Offset Correction: v_off_ini = -16.131 uV, v_off_fin = -24.465 uV 15:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.611 uVs 15:37:36 Integrated Voltage Measurement... 15:37:45 Voltage Offset Correction: v_off_ini = -13.207 uV, v_off_fin = -16.620 uV 15:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.773 uVs 15:37:45 Integrated Voltage Measurement... 15:37:54 Voltage Offset Correction: v_off_ini = -6.779 uV, v_off_fin = -17.514 uV 15:37:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.262 uVs 15:37:54 Integrated Voltage Measurement... 15:38:03 Voltage Offset Correction: v_off_ini = -17.988 uV, v_off_fin = -15.060 uV 15:38:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.632 uVs 15:38:03 Integrated Voltage Measurement... 15:38:12 Voltage Offset Correction: v_off_ini = -13.651 uV, v_off_fin = -19.091 uV 15:38:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.311 uVs 15:38:12 Integrated Voltage Measurement... 15:38:21 Voltage Offset Correction: v_off_ini = -24.944 uV, v_off_fin = -22.913 uV 15:38:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.620 uVs 15:38:24 I2Y Average and RMS of Measurements VT = -362.368 +- 4.244 uVs I2Y = -33.338 +- 0.390 uTm^2 15:38:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:38:33 Integrated Voltage Measurement... 15:38:41 Voltage Offset Correction: v_off_ini = -3.872 uV, v_off_fin = -17.052 uV 15:38:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.443 uVs 15:38:42 Integrated Voltage Measurement... 15:38:50 Voltage Offset Correction: v_off_ini = -0.754 uV, v_off_fin = -10.516 uV 15:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.429 uVs 15:38:51 Integrated Voltage Measurement... 15:38:59 Voltage Offset Correction: v_off_ini = -21.131 uV, v_off_fin = -16.019 uV 15:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.273 uVs 15:39:00 Integrated Voltage Measurement... 15:39:08 Voltage Offset Correction: v_off_ini = -6.307 uV, v_off_fin = 2.567 uV 15:39:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.726 uVs 15:39:09 Integrated Voltage Measurement... 15:39:17 Voltage Offset Correction: v_off_ini = -16.613 uV, v_off_fin = -9.201 uV 15:39:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.842 uVs 15:39:18 Integrated Voltage Measurement... 15:39:27 Voltage Offset Correction: v_off_ini = -9.926 uV, v_off_fin = 1.122 uV 15:39:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.381 uVs 15:39:31 I1X Average and RMS of Measurements VT = -52.682 +- 4.744 uVs I1X = 10.536 +- 0.949 uTm 15:39:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:39:37 Integrated Voltage Measurement... 15:39:46 Voltage Offset Correction: v_off_ini = -3.585 uV, v_off_fin = -7.170 uV 15:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.179 uVs 15:39:46 Integrated Voltage Measurement... 15:39:55 Voltage Offset Correction: v_off_ini = 6.077 uV, v_off_fin = 14.527 uV 15:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.417 uVs 15:39:55 Integrated Voltage Measurement... 15:40:04 Voltage Offset Correction: v_off_ini = 11.598 uV, v_off_fin = -1.108 uV 15:40:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.298 uVs 15:40:04 Integrated Voltage Measurement... 15:40:13 Voltage Offset Correction: v_off_ini = 4.624 uV, v_off_fin = 5.098 uV 15:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.272 uVs 15:40:13 Integrated Voltage Measurement... 15:40:22 Voltage Offset Correction: v_off_ini = 27.485 uV, v_off_fin = 20.120 uV 15:40:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.412 uVs 15:40:22 Integrated Voltage Measurement... 15:40:31 Voltage Offset Correction: v_off_ini = 19.895 uV, v_off_fin = 22.496 uV 15:40:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.819 uVs 15:40:36 I1Y Average and RMS of Measurements VT = -182.566 +- 3.854 uVs I1Y = -36.513 +- 0.771 uTm 15:40:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:40:43 Integrated Voltage Measurement... 15:40:52 Voltage Offset Correction: v_off_ini = 29.192 uV, v_off_fin = 35.545 uV 15:40:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -38.574 uVs 15:40:52 Integrated Voltage Measurement... 15:41:01 Voltage Offset Correction: v_off_ini = 28.224 uV, v_off_fin = 47.521 uV 15:41:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.381 uVs 15:41:01 Integrated Voltage Measurement... 15:41:10 Voltage Offset Correction: v_off_ini = 30.449 uV, v_off_fin = 25.150 uV 15:41:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.832 uVs 15:41:10 Integrated Voltage Measurement... 15:41:19 Voltage Offset Correction: v_off_ini = 32.165 uV, v_off_fin = 35.179 uV 15:41:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.104 uVs 15:41:19 Integrated Voltage Measurement... 15:41:28 Voltage Offset Correction: v_off_ini = 34.901 uV, v_off_fin = 22.689 uV 15:41:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.143 uVs 15:41:28 Integrated Voltage Measurement... 15:41:37 Voltage Offset Correction: v_off_ini = 30.158 uV, v_off_fin = 43.219 uV 15:41:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.881 uVs 15:41:40 I2X Average and RMS of Measurements VT = -51.486 +- 5.303 uVs I2X = 4.737 +- 0.488 uTm^2 15:41:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:41:48 Integrated Voltage Measurement... 15:41:57 Voltage Offset Correction: v_off_ini = 34.710 uV, v_off_fin = 31.777 uV 15:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.080 uVs 15:41:57 Integrated Voltage Measurement... 15:42:06 Voltage Offset Correction: v_off_ini = 33.794 uV, v_off_fin = 34.541 uV 15:42:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 349.703 uVs 15:42:06 Integrated Voltage Measurement... 15:42:15 Voltage Offset Correction: v_off_ini = 40.986 uV, v_off_fin = 29.350 uV 15:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.499 uVs 15:42:15 Integrated Voltage Measurement... 15:42:24 Voltage Offset Correction: v_off_ini = 34.879 uV, v_off_fin = 35.711 uV 15:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.767 uVs 15:42:24 Integrated Voltage Measurement... 15:42:33 Voltage Offset Correction: v_off_ini = 43.123 uV, v_off_fin = 41.686 uV 15:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.765 uVs 15:42:33 Integrated Voltage Measurement... 15:42:42 Voltage Offset Correction: v_off_ini = 41.726 uV, v_off_fin = 43.073 uV 15:42:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.433 uVs 15:42:44 I2Y Average and RMS of Measurements VT = -359.374 +- 1.612 uVs I2Y = -33.063 +- 0.149 uTm^2 15:42:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:53 Integrated Voltage Measurement... 15:43:02 Voltage Offset Correction: v_off_ini = 37.510 uV, v_off_fin = 31.861 uV 15:43:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -49.859 uVs 15:43:02 Integrated Voltage Measurement... 15:43:11 Voltage Offset Correction: v_off_ini = 42.721 uV, v_off_fin = 36.207 uV 15:43:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.036 uVs 15:43:11 Integrated Voltage Measurement... 15:43:20 Voltage Offset Correction: v_off_ini = 36.810 uV, v_off_fin = 23.388 uV 15:43:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.804 uVs 15:43:20 Integrated Voltage Measurement... 15:43:29 Voltage Offset Correction: v_off_ini = 38.025 uV, v_off_fin = 33.194 uV 15:43:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.370 uVs 15:43:29 Integrated Voltage Measurement... 15:43:38 Voltage Offset Correction: v_off_ini = 33.634 uV, v_off_fin = 25.075 uV 15:43:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.521 uVs 15:43:38 Integrated Voltage Measurement... 15:43:47 Voltage Offset Correction: v_off_ini = 35.391 uV, v_off_fin = 36.081 uV 15:43:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.344 uVs 15:43:51 I1X Average and RMS of Measurements VT = -58.323 +- 1.635 uVs I1X = 11.665 +- 0.327 uTm 15:43:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:58 Integrated Voltage Measurement... 15:44:07 Voltage Offset Correction: v_off_ini = 36.245 uV, v_off_fin = 24.713 uV 15:44:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.724 uVs 15:44:07 Integrated Voltage Measurement... 15:44:16 Voltage Offset Correction: v_off_ini = 33.860 uV, v_off_fin = 38.288 uV 15:44:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.699 uVs 15:44:16 Integrated Voltage Measurement... 15:44:25 Voltage Offset Correction: v_off_ini = 35.062 uV, v_off_fin = 28.054 uV 15:44:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.733 uVs 15:44:25 Integrated Voltage Measurement... 15:44:34 Voltage Offset Correction: v_off_ini = 33.323 uV, v_off_fin = 36.033 uV 15:44:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.405 uVs 15:44:34 Integrated Voltage Measurement... 15:44:43 Voltage Offset Correction: v_off_ini = 26.602 uV, v_off_fin = 23.067 uV 15:44:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.927 uVs 15:44:43 Integrated Voltage Measurement... 15:44:52 Voltage Offset Correction: v_off_ini = 28.385 uV, v_off_fin = 43.637 uV 15:44:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.759 uVs 15:44:56 I1Y Average and RMS of Measurements VT = -173.208 +- 0.719 uVs I1Y = -34.642 +- 0.144 uTm 15:45:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:04 Integrated Voltage Measurement... 15:45:13 Voltage Offset Correction: v_off_ini = 37.527 uV, v_off_fin = 14.624 uV 15:45:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.622 uVs 15:45:13 Integrated Voltage Measurement... 15:45:22 Voltage Offset Correction: v_off_ini = 41.258 uV, v_off_fin = 48.381 uV 15:45:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.834 uVs 15:45:22 Integrated Voltage Measurement... 15:45:31 Voltage Offset Correction: v_off_ini = 40.015 uV, v_off_fin = 25.731 uV 15:45:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.746 uVs 15:45:31 Integrated Voltage Measurement... 15:45:40 Voltage Offset Correction: v_off_ini = 33.447 uV, v_off_fin = 50.814 uV 15:45:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.234 uVs 15:45:40 Integrated Voltage Measurement... 15:45:49 Voltage Offset Correction: v_off_ini = 43.537 uV, v_off_fin = 24.460 uV 15:45:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.493 uVs 15:45:49 Integrated Voltage Measurement... 15:45:58 Voltage Offset Correction: v_off_ini = 28.013 uV, v_off_fin = 48.802 uV 15:45:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.683 uVs 15:46:00 I2X Average and RMS of Measurements VT = -49.102 +- 6.510 uVs I2X = 4.517 +- 0.599 uTm^2 15:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:08 Integrated Voltage Measurement... 15:46:17 Voltage Offset Correction: v_off_ini = 49.596 uV, v_off_fin = 48.022 uV 15:46:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.907 uVs 15:46:17 Integrated Voltage Measurement... 15:46:26 Voltage Offset Correction: v_off_ini = 48.004 uV, v_off_fin = 54.586 uV 15:46:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 366.944 uVs 15:46:26 Integrated Voltage Measurement... 15:46:35 Voltage Offset Correction: v_off_ini = 64.738 uV, v_off_fin = 51.284 uV 15:46:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.286 uVs 15:46:35 Integrated Voltage Measurement... 15:46:44 Voltage Offset Correction: v_off_ini = 55.655 uV, v_off_fin = 59.711 uV 15:46:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.248 uVs 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = 73.413 uV, v_off_fin = 61.063 uV 15:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.481 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = 70.768 uV, v_off_fin = 69.667 uV 15:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.325 uVs 15:47:05 I2Y Average and RMS of Measurements VT = -361.199 +- 5.201 uVs I2Y = -33.230 +- 0.478 uTm^2 15:47:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:47:14 Integrated Voltage Measurement... 15:47:23 Voltage Offset Correction: v_off_ini = 66.150 uV, v_off_fin = 61.014 uV 15:47:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.875 uVs 15:47:23 Integrated Voltage Measurement... 15:47:32 Voltage Offset Correction: v_off_ini = 57.135 uV, v_off_fin = 55.888 uV 15:47:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.764 uVs 15:47:32 Integrated Voltage Measurement... 15:47:41 Voltage Offset Correction: v_off_ini = 53.578 uV, v_off_fin = 63.431 uV 15:47:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.842 uVs 15:47:41 Integrated Voltage Measurement... 15:47:50 Voltage Offset Correction: v_off_ini = 71.630 uV, v_off_fin = 81.607 uV 15:47:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.169 uVs 15:47:50 Integrated Voltage Measurement... 15:47:59 Voltage Offset Correction: v_off_ini = 56.555 uV, v_off_fin = 61.533 uV 15:47:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.035 uVs 15:47:59 Integrated Voltage Measurement... 15:48:08 Voltage Offset Correction: v_off_ini = 56.710 uV, v_off_fin = 58.613 uV 15:48:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.289 uVs 15:48:12 I1X Average and RMS of Measurements VT = -74.829 +- 7.619 uVs I1X = 14.966 +- 1.523 uTm 15:48:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:48:19 Integrated Voltage Measurement... 15:48:28 Voltage Offset Correction: v_off_ini = 61.950 uV, v_off_fin = 57.687 uV 15:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.410 uVs 15:48:28 Integrated Voltage Measurement... 15:48:36 Voltage Offset Correction: v_off_ini = 49.965 uV, v_off_fin = 47.541 uV 15:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.030 uVs 15:48:37 Integrated Voltage Measurement... 15:48:45 Voltage Offset Correction: v_off_ini = 42.983 uV, v_off_fin = 44.247 uV 15:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.084 uVs 15:48:46 Integrated Voltage Measurement... 15:48:54 Voltage Offset Correction: v_off_ini = 50.186 uV, v_off_fin = 50.783 uV 15:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.835 uVs 15:48:55 Integrated Voltage Measurement... 15:49:03 Voltage Offset Correction: v_off_ini = 54.412 uV, v_off_fin = 33.895 uV 15:49:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.183 uVs 15:49:04 Integrated Voltage Measurement... 15:49:12 Voltage Offset Correction: v_off_ini = 42.850 uV, v_off_fin = 57.452 uV 15:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.679 uVs 15:49:17 I1Y Average and RMS of Measurements VT = -179.704 +- 0.905 uVs I1Y = -35.941 +- 0.181 uTm 15:49:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:49:24 Integrated Voltage Measurement... 15:49:33 Voltage Offset Correction: v_off_ini = 44.573 uV, v_off_fin = 38.481 uV 15:49:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.609 uVs 15:49:33 Integrated Voltage Measurement... 15:49:42 Voltage Offset Correction: v_off_ini = 51.707 uV, v_off_fin = 46.778 uV 15:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.783 uVs 15:49:42 Integrated Voltage Measurement... 15:49:51 Voltage Offset Correction: v_off_ini = 49.545 uV, v_off_fin = 49.217 uV 15:49:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -56.491 uVs 15:49:51 Integrated Voltage Measurement... 15:50:00 Voltage Offset Correction: v_off_ini = 48.070 uV, v_off_fin = 63.549 uV 15:50:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.690 uVs 15:50:01 Integrated Voltage Measurement... 15:50:09 Voltage Offset Correction: v_off_ini = 47.344 uV, v_off_fin = 35.725 uV 15:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.117 uVs 15:50:10 Integrated Voltage Measurement... 15:50:18 Voltage Offset Correction: v_off_ini = 50.269 uV, v_off_fin = 45.810 uV 15:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.698 uVs 15:50:21 I2X Average and RMS of Measurements VT = -58.898 +- 6.668 uVs I2X = 5.419 +- 0.613 uTm^2 15:50:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:50:29 Integrated Voltage Measurement... 15:50:38 Voltage Offset Correction: v_off_ini = 46.035 uV, v_off_fin = 49.255 uV 15:50:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.821 uVs 15:50:38 Integrated Voltage Measurement... 15:50:47 Voltage Offset Correction: v_off_ini = 45.946 uV, v_off_fin = 34.311 uV 15:50:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.173 uVs 15:50:47 Integrated Voltage Measurement... 15:50:56 Voltage Offset Correction: v_off_ini = 23.767 uV, v_off_fin = 25.031 uV 15:50:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.594 uVs 15:50:56 Integrated Voltage Measurement... 15:51:05 Voltage Offset Correction: v_off_ini = 16.251 uV, v_off_fin = 34.069 uV 15:51:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.260 uVs 15:51:05 Integrated Voltage Measurement... 15:51:14 Voltage Offset Correction: v_off_ini = 39.870 uV, v_off_fin = 34.229 uV 15:51:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.355 uVs 15:51:14 Integrated Voltage Measurement... 15:51:23 Voltage Offset Correction: v_off_ini = 33.300 uV, v_off_fin = 23.536 uV 15:51:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.668 uVs 15:51:25 I2Y Average and RMS of Measurements VT = -361.312 +- 2.872 uVs I2Y = -33.241 +- 0.264 uTm^2 15:51:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:51:34 Integrated Voltage Measurement... 15:51:43 Voltage Offset Correction: v_off_ini = 27.843 uV, v_off_fin = 28.270 uV 15:51:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.984 uVs 15:51:43 Integrated Voltage Measurement... 15:51:52 Voltage Offset Correction: v_off_ini = 27.020 uV, v_off_fin = 35.048 uV 15:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.052 uVs 15:51:52 Integrated Voltage Measurement... 15:52:01 Voltage Offset Correction: v_off_ini = 36.177 uV, v_off_fin = 27.827 uV 15:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.571 uVs 15:52:01 Integrated Voltage Measurement... 15:52:10 Voltage Offset Correction: v_off_ini = 28.832 uV, v_off_fin = 43.141 uV 15:52:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.746 uVs 15:52:10 Integrated Voltage Measurement... 15:52:19 Voltage Offset Correction: v_off_ini = 32.503 uV, v_off_fin = 26.237 uV 15:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.562 uVs 15:52:19 Integrated Voltage Measurement... 15:52:28 Voltage Offset Correction: v_off_ini = 18.577 uV, v_off_fin = 25.388 uV 15:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.089 uVs 15:52:32 I1X Average and RMS of Measurements VT = -81.334 +- 3.913 uVs I1X = 16.268 +- 0.782 uTm 15:52:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:52:39 Integrated Voltage Measurement... 15:52:48 Voltage Offset Correction: v_off_ini = 22.256 uV, v_off_fin = 17.593 uV 15:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.673 uVs 15:52:48 Integrated Voltage Measurement... 15:52:57 Voltage Offset Correction: v_off_ini = 12.476 uV, v_off_fin = 37.387 uV 15:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.050 uVs 15:52:57 Integrated Voltage Measurement... 15:53:06 Voltage Offset Correction: v_off_ini = 40.082 uV, v_off_fin = 24.228 uV 15:53:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.365 uVs 15:53:06 Integrated Voltage Measurement... 15:53:15 Voltage Offset Correction: v_off_ini = 30.097 uV, v_off_fin = 33.356 uV 15:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.443 uVs 15:53:15 Integrated Voltage Measurement... 15:53:24 Voltage Offset Correction: v_off_ini = 35.634 uV, v_off_fin = 27.311 uV 15:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.002 uVs 15:53:24 Integrated Voltage Measurement... 15:53:33 Voltage Offset Correction: v_off_ini = 29.498 uV, v_off_fin = 50.769 uV 15:53:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.561 uVs 15:53:37 I1Y Average and RMS of Measurements VT = -170.349 +- 3.393 uVs I1Y = -34.070 +- 0.679 uTm 15:53:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:53:45 Integrated Voltage Measurement... 15:53:54 Voltage Offset Correction: v_off_ini = 13.413 uV, v_off_fin = 20.196 uV 15:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.234 uVs 15:53:54 Integrated Voltage Measurement... 15:54:03 Voltage Offset Correction: v_off_ini = 27.133 uV, v_off_fin = 17.205 uV 15:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.545 uVs 15:54:03 Integrated Voltage Measurement... 15:54:12 Voltage Offset Correction: v_off_ini = 22.951 uV, v_off_fin = 22.086 uV 15:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.008 uVs 15:54:12 Integrated Voltage Measurement... 15:54:21 Voltage Offset Correction: v_off_ini = 20.449 uV, v_off_fin = 28.690 uV 15:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.936 uVs 15:54:21 Integrated Voltage Measurement... 15:54:30 Voltage Offset Correction: v_off_ini = 28.354 uV, v_off_fin = 20.222 uV 15:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.610 uVs 15:54:30 Integrated Voltage Measurement... 15:54:39 Voltage Offset Correction: v_off_ini = 32.501 uV, v_off_fin = 25.681 uV 15:54:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.780 uVs 15:54:42 I2X Average and RMS of Measurements VT = -78.852 +- 3.729 uVs I2X = 7.255 +- 0.343 uTm^2 15:54:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:54:49 Integrated Voltage Measurement... 15:54:58 Voltage Offset Correction: v_off_ini = 31.551 uV, v_off_fin = 31.858 uV 15:54:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.828 uVs 15:54:58 Integrated Voltage Measurement... 15:55:07 Voltage Offset Correction: v_off_ini = 37.570 uV, v_off_fin = 23.364 uV 15:55:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.329 uVs 15:55:07 Integrated Voltage Measurement... 15:55:16 Voltage Offset Correction: v_off_ini = 39.197 uV, v_off_fin = 32.257 uV 15:55:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.965 uVs 15:55:16 Integrated Voltage Measurement... 15:55:25 Voltage Offset Correction: v_off_ini = 30.581 uV, v_off_fin = 23.820 uV 15:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.734 uVs 15:55:26 Integrated Voltage Measurement... 15:55:34 Voltage Offset Correction: v_off_ini = 37.904 uV, v_off_fin = 39.071 uV 15:55:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.605 uVs 15:55:35 Integrated Voltage Measurement... 15:55:44 Voltage Offset Correction: v_off_ini = 45.106 uV, v_off_fin = 44.880 uV 15:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.967 uVs 15:55:46 I2Y Average and RMS of Measurements VT = -363.905 +- 7.775 uVs I2Y = -33.479 +- 0.715 uTm^2 15:55:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:55:58 Integrated Voltage Measurement... 15:56:07 Voltage Offset Correction: v_off_ini = 27.016 uV, v_off_fin = 20.458 uV 15:56:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.870 uVs 15:56:07 Integrated Voltage Measurement... 15:56:16 Voltage Offset Correction: v_off_ini = 24.266 uV, v_off_fin = 24.522 uV 15:56:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 56.141 uVs 15:56:16 Integrated Voltage Measurement... 15:56:25 Voltage Offset Correction: v_off_ini = 30.087 uV, v_off_fin = 29.655 uV 15:56:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.133 uVs 15:56:25 Integrated Voltage Measurement... 15:56:34 Voltage Offset Correction: v_off_ini = 22.594 uV, v_off_fin = 28.013 uV 15:56:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.095 uVs 15:56:34 Integrated Voltage Measurement... 15:56:43 Voltage Offset Correction: v_off_ini = 29.177 uV, v_off_fin = 25.176 uV 15:56:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.308 uVs 15:56:43 Integrated Voltage Measurement... 15:56:52 Voltage Offset Correction: v_off_ini = 41.732 uV, v_off_fin = 36.053 uV 15:56:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 36.864 uVs 15:56:56 I1X Average and RMS of Measurements VT = -52.569 +- 11.607 uVs I1X = 10.515 +- 2.322 uTm 15:56:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:57:03 Integrated Voltage Measurement... 15:57:12 Voltage Offset Correction: v_off_ini = 23.408 uV, v_off_fin = 18.254 uV 15:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.708 uVs 15:57:12 Integrated Voltage Measurement... 15:57:21 Voltage Offset Correction: v_off_ini = 33.195 uV, v_off_fin = 46.848 uV 15:57:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.312 uVs 15:57:21 Integrated Voltage Measurement... 15:57:30 Voltage Offset Correction: v_off_ini = 25.572 uV, v_off_fin = 26.622 uV 15:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.068 uVs 15:57:30 Integrated Voltage Measurement... 15:57:39 Voltage Offset Correction: v_off_ini = 33.566 uV, v_off_fin = 41.184 uV 15:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.147 uVs 15:57:39 Integrated Voltage Measurement... 15:57:48 Voltage Offset Correction: v_off_ini = 24.854 uV, v_off_fin = 29.497 uV 15:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.686 uVs 15:57:48 Integrated Voltage Measurement... 15:57:57 Voltage Offset Correction: v_off_ini = 34.540 uV, v_off_fin = 44.277 uV 15:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.521 uVs 15:58:01 I1Y Average and RMS of Measurements VT = -167.907 +- 5.696 uVs I1Y = -33.582 +- 1.139 uTm 15:58:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:58:06 Integrated Voltage Measurement... 15:58:15 Voltage Offset Correction: v_off_ini = 11.784 uV, v_off_fin = 7.362 uV 15:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.203 uVs 15:58:15 Integrated Voltage Measurement... 15:58:24 Voltage Offset Correction: v_off_ini = 7.691 uV, v_off_fin = 19.292 uV 15:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.840 uVs 15:58:24 Integrated Voltage Measurement... 15:58:33 Voltage Offset Correction: v_off_ini = 5.879 uV, v_off_fin = 0.834 uV 15:58:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.531 uVs 15:58:33 Integrated Voltage Measurement... 15:58:42 Voltage Offset Correction: v_off_ini = 12.900 uV, v_off_fin = 11.056 uV 15:58:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.473 uVs 15:58:42 Integrated Voltage Measurement... 15:58:51 Voltage Offset Correction: v_off_ini = -4.258 uV, v_off_fin = -4.789 uV 15:58:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -56.453 uVs 15:58:52 Integrated Voltage Measurement... 15:59:00 Voltage Offset Correction: v_off_ini = -1.046 uV, v_off_fin = 3.927 uV 15:59:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.514 uVs 15:59:03 I2X Average and RMS of Measurements VT = -50.836 +- 3.779 uVs I2X = 4.677 +- 0.348 uTm^2 15:59:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:59:08 Integrated Voltage Measurement... 15:59:17 Voltage Offset Correction: v_off_ini = -1.739 uV, v_off_fin = -4.602 uV 15:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.446 uVs 15:59:17 Integrated Voltage Measurement... 15:59:26 Voltage Offset Correction: v_off_ini = -3.828 uV, v_off_fin = -2.306 uV 15:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.470 uVs 15:59:26 Integrated Voltage Measurement... 15:59:35 Voltage Offset Correction: v_off_ini = -13.196 uV, v_off_fin = -14.358 uV 15:59:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.675 uVs 15:59:35 Integrated Voltage Measurement... 15:59:44 Voltage Offset Correction: v_off_ini = -16.609 uV, v_off_fin = -10.533 uV 15:59:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.599 uVs 15:59:44 Integrated Voltage Measurement... 15:59:53 Voltage Offset Correction: v_off_ini = -3.433 uV, v_off_fin = -5.143 uV 15:59:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.870 uVs 15:59:53 Integrated Voltage Measurement... 16:00:02 Voltage Offset Correction: v_off_ini = -21.593 uV, v_off_fin = -13.269 uV 16:00:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 364.589 uVs 16:00:05 I2Y Average and RMS of Measurements VT = -356.941 +- 7.322 uVs I2Y = -32.839 +- 0.674 uTm^2 16:00:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:00:13 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = -27.294 uV, v_off_fin = -37.089 uV 16:00:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -49.251 uVs 16:00:22 Integrated Voltage Measurement... 16:00:31 Voltage Offset Correction: v_off_ini = -30.629 uV, v_off_fin = -22.914 uV 16:00:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.803 uVs 16:00:31 Integrated Voltage Measurement... 16:00:40 Voltage Offset Correction: v_off_ini = -33.823 uV, v_off_fin = -33.690 uV 16:00:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.187 uVs 16:00:40 Integrated Voltage Measurement... 16:00:49 Voltage Offset Correction: v_off_ini = -30.539 uV, v_off_fin = -30.154 uV 16:00:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.935 uVs 16:00:49 Integrated Voltage Measurement... 16:00:58 Voltage Offset Correction: v_off_ini = -36.224 uV, v_off_fin = -24.547 uV 16:00:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.703 uVs 16:00:58 Integrated Voltage Measurement... 16:01:07 Voltage Offset Correction: v_off_ini = -28.301 uV, v_off_fin = -14.954 uV 16:01:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.618 uVs 16:01:11 I1X Average and RMS of Measurements VT = -51.916 +- 7.026 uVs I1X = 10.384 +- 1.405 uTm 16:01:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:01:18 Integrated Voltage Measurement... 16:01:27 Voltage Offset Correction: v_off_ini = -17.950 uV, v_off_fin = -37.638 uV 16:01:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.488 uVs 16:01:27 Integrated Voltage Measurement... 16:01:36 Voltage Offset Correction: v_off_ini = -19.314 uV, v_off_fin = -6.023 uV 16:01:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 168.487 uVs 16:01:36 Integrated Voltage Measurement... 16:01:45 Voltage Offset Correction: v_off_ini = -16.668 uV, v_off_fin = -16.323 uV 16:01:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.204 uVs 16:01:45 Integrated Voltage Measurement... 16:01:54 Voltage Offset Correction: v_off_ini = -17.147 uV, v_off_fin = 1.241 uV 16:01:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.381 uVs 16:01:54 Integrated Voltage Measurement... 16:02:03 Voltage Offset Correction: v_off_ini = -21.676 uV, v_off_fin = -23.759 uV 16:02:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.241 uVs 16:02:03 Integrated Voltage Measurement... 16:02:12 Voltage Offset Correction: v_off_ini = -31.495 uV, v_off_fin = -26.033 uV 16:02:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.995 uVs 16:02:16 I1Y Average and RMS of Measurements VT = -171.799 +- 5.212 uVs I1Y = -34.360 +- 1.043 uTm 16:02:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:02:21 Integrated Voltage Measurement... 16:02:30 Voltage Offset Correction: v_off_ini = -34.875 uV, v_off_fin = -39.559 uV 16:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.143 uVs 16:02:30 Integrated Voltage Measurement... 16:02:39 Voltage Offset Correction: v_off_ini = -17.861 uV, v_off_fin = -16.093 uV 16:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.702 uVs 16:02:40 Integrated Voltage Measurement... 16:02:48 Voltage Offset Correction: v_off_ini = -18.601 uV, v_off_fin = -30.404 uV 16:02:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.304 uVs 16:02:49 Integrated Voltage Measurement... 16:02:58 Voltage Offset Correction: v_off_ini = -15.849 uV, v_off_fin = -16.980 uV 16:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.644 uVs 16:02:58 Integrated Voltage Measurement... 16:03:07 Voltage Offset Correction: v_off_ini = -15.487 uV, v_off_fin = -21.590 uV 16:03:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -48.554 uVs 16:03:07 Integrated Voltage Measurement... 16:03:16 Voltage Offset Correction: v_off_ini = -27.584 uV, v_off_fin = -15.595 uV 16:03:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.197 uVs 16:03:18 I2X Average and RMS of Measurements VT = -52.424 +- 7.069 uVs I2X = 4.823 +- 0.650 uTm^2 16:03:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:03:23 Integrated Voltage Measurement... 16:03:32 Voltage Offset Correction: v_off_ini = -20.554 uV, v_off_fin = -26.881 uV 16:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.160 uVs 16:03:32 Integrated Voltage Measurement... 16:03:41 Voltage Offset Correction: v_off_ini = -15.710 uV, v_off_fin = -16.676 uV 16:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.878 uVs 16:03:41 Integrated Voltage Measurement... 16:03:50 Voltage Offset Correction: v_off_ini = -18.790 uV, v_off_fin = -27.971 uV 16:03:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -339.505 uVs 16:03:50 Integrated Voltage Measurement... 16:03:59 Voltage Offset Correction: v_off_ini = -31.545 uV, v_off_fin = -20.068 uV 16:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.185 uVs 16:03:59 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = -7.975 uV, v_off_fin = -33.414 uV 16:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.654 uVs 16:04:08 Integrated Voltage Measurement... 16:04:17 Voltage Offset Correction: v_off_ini = -23.949 uV, v_off_fin = -26.182 uV 16:04:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.474 uVs 16:04:20 I2Y Average and RMS of Measurements VT = -355.143 +- 12.328 uVs I2Y = -32.674 +- 1.134 uTm^2 16:04:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:28 Integrated Voltage Measurement... 16:04:37 Voltage Offset Correction: v_off_ini = -33.169 uV, v_off_fin = -26.975 uV 16:04:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -49.784 uVs 16:04:37 Integrated Voltage Measurement... 16:04:46 Voltage Offset Correction: v_off_ini = -21.880 uV, v_off_fin = -31.305 uV 16:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 40.609 uVs 16:04:46 Integrated Voltage Measurement... 16:04:55 Voltage Offset Correction: v_off_ini = -36.690 uV, v_off_fin = -25.657 uV 16:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.912 uVs 16:04:55 Integrated Voltage Measurement... 16:05:04 Voltage Offset Correction: v_off_ini = -21.363 uV, v_off_fin = -6.193 uV 16:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.408 uVs 16:05:04 Integrated Voltage Measurement... 16:05:13 Voltage Offset Correction: v_off_ini = -16.548 uV, v_off_fin = -25.221 uV 16:05:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.826 uVs 16:05:13 Integrated Voltage Measurement... 16:05:22 Voltage Offset Correction: v_off_ini = -17.522 uV, v_off_fin = -3.249 uV 16:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.430 uVs 16:05:26 I1X Average and RMS of Measurements VT = -55.828 +- 11.393 uVs I1X = 11.166 +- 2.278 uTm 16:05:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:33 Integrated Voltage Measurement... 16:05:42 Voltage Offset Correction: v_off_ini = -14.952 uV, v_off_fin = -26.906 uV 16:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.495 uVs 16:05:42 Integrated Voltage Measurement... 16:05:51 Voltage Offset Correction: v_off_ini = -12.811 uV, v_off_fin = -4.811 uV 16:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.623 uVs 16:05:51 Integrated Voltage Measurement... 16:06:00 Voltage Offset Correction: v_off_ini = -12.621 uV, v_off_fin = -6.998 uV 16:06:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.216 uVs 16:06:00 Integrated Voltage Measurement... 16:06:09 Voltage Offset Correction: v_off_ini = -13.459 uV, v_off_fin = -7.753 uV 16:06:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 195.354 uVs 16:06:09 Integrated Voltage Measurement... 16:06:18 Voltage Offset Correction: v_off_ini = -3.215 uV, v_off_fin = -5.408 uV 16:06:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.310 uVs 16:06:18 Integrated Voltage Measurement... 16:06:27 Voltage Offset Correction: v_off_ini = 2.926 uV, v_off_fin = 9.419 uV 16:06:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.216 uVs 16:06:31 I1Y Average and RMS of Measurements VT = -172.869 +- 3.424 uVs I1Y = -34.574 +- 0.685 uTm 16:06:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:37 Integrated Voltage Measurement... 16:06:46 Voltage Offset Correction: v_off_ini = 3.153 uV, v_off_fin = -0.601 uV 16:06:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.600 uVs 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = -11.451 uV, v_off_fin = 9.403 uV 16:06:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.140 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = -2.064 uV, v_off_fin = -13.280 uV 16:07:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.243 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 3.369 uV, v_off_fin = 10.207 uV 16:07:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.317 uVs 16:07:13 Integrated Voltage Measurement... 16:07:22 Voltage Offset Correction: v_off_ini = -5.303 uV, v_off_fin = -12.007 uV 16:07:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.225 uVs 16:07:22 Integrated Voltage Measurement... 16:07:31 Voltage Offset Correction: v_off_ini = 2.072 uV, v_off_fin = 9.153 uV 16:07:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.602 uVs 16:07:33 I2X Average and RMS of Measurements VT = -58.355 +- 2.127 uVs I2X = 5.369 +- 0.196 uTm^2 16:07:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:38 Integrated Voltage Measurement... 16:07:47 Voltage Offset Correction: v_off_ini = -7.309 uV, v_off_fin = -13.545 uV 16:07:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.255 uVs 16:07:47 Integrated Voltage Measurement... 16:07:56 Voltage Offset Correction: v_off_ini = -10.016 uV, v_off_fin = -8.936 uV 16:07:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.409 uVs 16:07:56 Integrated Voltage Measurement... 16:08:05 Voltage Offset Correction: v_off_ini = -8.473 uV, v_off_fin = -10.958 uV 16:08:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.523 uVs 16:08:05 Integrated Voltage Measurement... 16:08:14 Voltage Offset Correction: v_off_ini = -4.048 uV, v_off_fin = -12.882 uV 16:08:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.028 uVs 16:08:14 Integrated Voltage Measurement... 16:08:23 Voltage Offset Correction: v_off_ini = -0.641 uV, v_off_fin = -10.149 uV 16:08:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.546 uVs 16:08:23 Integrated Voltage Measurement... 16:08:32 Voltage Offset Correction: v_off_ini = -10.602 uV, v_off_fin = -15.252 uV 16:08:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.808 uVs 16:08:35 I2Y Average and RMS of Measurements VT = -361.928 +- 2.018 uVs I2Y = -33.297 +- 0.186 uTm^2 16:08:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:08:43 Integrated Voltage Measurement... 16:08:52 Voltage Offset Correction: v_off_ini = -16.969 uV, v_off_fin = -28.911 uV 16:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -34.805 uVs 16:08:52 Integrated Voltage Measurement... 16:09:01 Voltage Offset Correction: v_off_ini = -32.556 uV, v_off_fin = -18.499 uV 16:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 47.156 uVs 16:09:01 Integrated Voltage Measurement... 16:09:10 Voltage Offset Correction: v_off_ini = -5.702 uV, v_off_fin = -19.111 uV 16:09:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -54.057 uVs 16:09:10 Integrated Voltage Measurement... 16:09:19 Voltage Offset Correction: v_off_ini = -5.111 uV, v_off_fin = -8.247 uV 16:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 60.324 uVs 16:09:19 Integrated Voltage Measurement... 16:09:28 Voltage Offset Correction: v_off_ini = -12.203 uV, v_off_fin = -9.267 uV 16:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.477 uVs 16:09:28 Integrated Voltage Measurement... 16:09:37 Voltage Offset Correction: v_off_ini = -2.659 uV, v_off_fin = -7.308 uV 16:09:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 46.469 uVs 16:09:41 I1X Average and RMS of Measurements VT = -49.548 +- 6.650 uVs I1X = 9.911 +- 1.330 uTm 16:09:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:09:48 Integrated Voltage Measurement... 16:09:57 Voltage Offset Correction: v_off_ini = -21.298 uV, v_off_fin = -28.580 uV 16:09:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.108 uVs 16:09:57 Integrated Voltage Measurement... 16:10:06 Voltage Offset Correction: v_off_ini = -13.270 uV, v_off_fin = -5.375 uV 16:10:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.132 uVs 16:10:06 Integrated Voltage Measurement... 16:10:15 Voltage Offset Correction: v_off_ini = -14.065 uV, v_off_fin = -18.389 uV 16:10:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.010 uVs 16:10:15 Integrated Voltage Measurement... 16:10:24 Voltage Offset Correction: v_off_ini = -9.998 uV, v_off_fin = 2.427 uV 16:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.314 uVs 16:10:24 Integrated Voltage Measurement... 16:10:33 Voltage Offset Correction: v_off_ini = 5.283 uV, v_off_fin = -13.792 uV 16:10:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.768 uVs 16:10:33 Integrated Voltage Measurement... 16:10:42 Voltage Offset Correction: v_off_ini = -9.799 uV, v_off_fin = 1.831 uV 16:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.240 uVs 16:10:46 I1Y Average and RMS of Measurements VT = -171.095 +- 1.822 uVs I1Y = -34.217 +- 0.364 uTm 16:10:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:10:52 Integrated Voltage Measurement... 16:11:01 Voltage Offset Correction: v_off_ini = -15.941 uV, v_off_fin = -19.927 uV 16:11:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.017 uVs 16:11:01 Integrated Voltage Measurement... 16:11:10 Voltage Offset Correction: v_off_ini = -22.276 uV, v_off_fin = -8.157 uV 16:11:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.463 uVs 16:11:10 Integrated Voltage Measurement... 16:11:19 Voltage Offset Correction: v_off_ini = -2.894 uV, v_off_fin = -19.157 uV 16:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.004 uVs 16:11:19 Integrated Voltage Measurement... 16:11:28 Voltage Offset Correction: v_off_ini = -12.816 uV, v_off_fin = 2.651 uV 16:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.021 uVs 16:11:28 Integrated Voltage Measurement... 16:11:37 Voltage Offset Correction: v_off_ini = -6.510 uV, v_off_fin = -4.555 uV 16:11:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.734 uVs 16:11:37 Integrated Voltage Measurement... 16:11:46 Voltage Offset Correction: v_off_ini = -1.899 uV, v_off_fin = 13.164 uV 16:11:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.962 uVs 16:11:48 I2X Average and RMS of Measurements VT = -48.867 +- 3.526 uVs I2X = 4.496 +- 0.324 uTm^2 16:11:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:11:53 Integrated Voltage Measurement... 16:12:02 Voltage Offset Correction: v_off_ini = 5.625 uV, v_off_fin = -2.918 uV 16:12:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.995 uVs 16:12:02 Integrated Voltage Measurement... 16:12:11 Voltage Offset Correction: v_off_ini = -0.277 uV, v_off_fin = -3.903 uV 16:12:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.581 uVs 16:12:11 Integrated Voltage Measurement... 16:12:20 Voltage Offset Correction: v_off_ini = -2.900 uV, v_off_fin = 0.997 uV 16:12:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.414 uVs 16:12:20 Integrated Voltage Measurement... 16:12:29 Voltage Offset Correction: v_off_ini = 9.822 uV, v_off_fin = -2.601 uV 16:12:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.274 uVs 16:12:29 Integrated Voltage Measurement... 16:12:38 Voltage Offset Correction: v_off_ini = 1.277 uV, v_off_fin = 1.080 uV 16:12:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -375.683 uVs 16:12:38 Integrated Voltage Measurement... 16:12:47 Voltage Offset Correction: v_off_ini = 6.429 uV, v_off_fin = 0.124 uV 16:12:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.223 uVs 16:12:50 I2Y Average and RMS of Measurements VT = -362.528 +- 3.152 uVs I2Y = -33.353 +- 0.290 uTm^2 16:12:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:12:58 Integrated Voltage Measurement... 16:13:07 Voltage Offset Correction: v_off_ini = 7.117 uV, v_off_fin = -4.000 uV 16:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.644 uVs 16:13:07 Integrated Voltage Measurement... 16:13:16 Voltage Offset Correction: v_off_ini = 4.475 uV, v_off_fin = -4.463 uV 16:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.808 uVs 16:13:16 Integrated Voltage Measurement... 16:13:25 Voltage Offset Correction: v_off_ini = -9.010 uV, v_off_fin = -12.937 uV 16:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.478 uVs 16:13:25 Integrated Voltage Measurement... 16:13:34 Voltage Offset Correction: v_off_ini = 3.539 uV, v_off_fin = 6.320 uV 16:13:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.951 uVs 16:13:34 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = 7.632 uV, v_off_fin = -10.053 uV 16:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.223 uVs 16:13:43 Integrated Voltage Measurement... 16:13:52 Voltage Offset Correction: v_off_ini = 1.676 uV, v_off_fin = -11.271 uV 16:13:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.307 uVs 16:13:56 I1X Average and RMS of Measurements VT = -42.902 +- 8.803 uVs I1X = 8.580 +- 1.761 uTm 16:13:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:14:03 Integrated Voltage Measurement... 16:14:12 Voltage Offset Correction: v_off_ini = -35.394 uV, v_off_fin = -33.863 uV 16:14:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.879 uVs 16:14:12 Integrated Voltage Measurement... 16:14:21 Voltage Offset Correction: v_off_ini = -15.149 uV, v_off_fin = 8.276 uV 16:14:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.064 uVs 16:14:21 Integrated Voltage Measurement... 16:14:30 Voltage Offset Correction: v_off_ini = -9.636 uV, v_off_fin = -17.152 uV 16:14:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.163 uVs 16:14:30 Integrated Voltage Measurement... 16:14:39 Voltage Offset Correction: v_off_ini = -8.936 uV, v_off_fin = -8.721 uV 16:14:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.396 uVs 16:14:39 Integrated Voltage Measurement... 16:14:48 Voltage Offset Correction: v_off_ini = -16.197 uV, v_off_fin = -25.222 uV 16:14:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.954 uVs 16:14:48 Integrated Voltage Measurement... 16:14:57 Voltage Offset Correction: v_off_ini = -6.129 uV, v_off_fin = 11.145 uV 16:14:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.327 uVs 16:15:01 I1Y Average and RMS of Measurements VT = -176.964 +- 4.245 uVs I1Y = -35.390 +- 0.849 uTm 16:15:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:15:06 Integrated Voltage Measurement... 16:15:15 Voltage Offset Correction: v_off_ini = -12.115 uV, v_off_fin = -17.362 uV 16:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.169 uVs 16:15:16 Integrated Voltage Measurement... 16:15:24 Voltage Offset Correction: v_off_ini = -4.082 uV, v_off_fin = -3.290 uV 16:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.036 uVs 16:15:25 Integrated Voltage Measurement... 16:15:34 Voltage Offset Correction: v_off_ini = -8.627 uV, v_off_fin = -7.431 uV 16:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.022 uVs 16:15:34 Integrated Voltage Measurement... 16:15:43 Voltage Offset Correction: v_off_ini = 9.854 uV, v_off_fin = 6.782 uV 16:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.286 uVs 16:15:43 Integrated Voltage Measurement... 16:15:52 Voltage Offset Correction: v_off_ini = 7.133 uV, v_off_fin = -18.981 uV 16:15:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.375 uVs 16:15:52 Integrated Voltage Measurement... 16:16:01 Voltage Offset Correction: v_off_ini = -14.533 uV, v_off_fin = 2.454 uV 16:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.584 uVs 16:16:03 I2X Average and RMS of Measurements VT = -41.579 +- 9.461 uVs I2X = 3.825 +- 0.870 uTm^2 16:16:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:16:08 Integrated Voltage Measurement... 16:16:17 Voltage Offset Correction: v_off_ini = -0.656 uV, v_off_fin = -3.194 uV 16:16:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -373.527 uVs 16:16:17 Integrated Voltage Measurement... 16:16:26 Voltage Offset Correction: v_off_ini = -16.241 uV, v_off_fin = -12.724 uV 16:16:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.819 uVs 16:16:26 Integrated Voltage Measurement... 16:16:35 Voltage Offset Correction: v_off_ini = -7.930 uV, v_off_fin = -6.555 uV 16:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.698 uVs 16:16:35 Integrated Voltage Measurement... 16:16:44 Voltage Offset Correction: v_off_ini = -2.452 uV, v_off_fin = -2.763 uV 16:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.370 uVs 16:16:44 Integrated Voltage Measurement... 16:16:53 Voltage Offset Correction: v_off_ini = 1.617 uV, v_off_fin = -9.985 uV 16:16:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.321 uVs 16:16:53 Integrated Voltage Measurement... 16:17:02 Voltage Offset Correction: v_off_ini = 7.780 uV, v_off_fin = 1.091 uV 16:17:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 360.407 uVs 16:17:05 I2Y Average and RMS of Measurements VT = -364.190 +- 5.483 uVs I2Y = -33.506 +- 0.504 uTm^2 16:17:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:17:26 Integrated Voltage Measurement... 16:17:35 Voltage Offset Correction: v_off_ini = -17.556 uV, v_off_fin = -15.927 uV 16:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -44.043 uVs 16:17:35 Integrated Voltage Measurement... 16:17:44 Voltage Offset Correction: v_off_ini = -17.174 uV, v_off_fin = 2.572 uV 16:17:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.825 uVs 16:17:44 Integrated Voltage Measurement... 16:17:53 Voltage Offset Correction: v_off_ini = -15.454 uV, v_off_fin = -30.060 uV 16:17:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.010 uVs 16:17:53 Integrated Voltage Measurement... 16:18:02 Voltage Offset Correction: v_off_ini = -30.849 uV, v_off_fin = -25.486 uV 16:18:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.666 uVs 16:18:02 Integrated Voltage Measurement... 16:18:11 Voltage Offset Correction: v_off_ini = -19.442 uV, v_off_fin = -32.505 uV 16:18:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.690 uVs 16:18:11 Integrated Voltage Measurement... 16:18:20 Voltage Offset Correction: v_off_ini = -30.771 uV, v_off_fin = -22.551 uV 16:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.478 uVs 16:18:24 I1X Average and RMS of Measurements VT = -46.619 +- 1.468 uVs I1X = 9.324 +- 0.294 uTm 16:18:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:18:31 Integrated Voltage Measurement... 16:18:40 Voltage Offset Correction: v_off_ini = -33.283 uV, v_off_fin = -28.359 uV 16:18:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -175.929 uVs 16:18:40 Integrated Voltage Measurement... 16:18:49 Voltage Offset Correction: v_off_ini = -19.789 uV, v_off_fin = -18.314 uV 16:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.858 uVs 16:18:49 Integrated Voltage Measurement... 16:18:58 Voltage Offset Correction: v_off_ini = -8.457 uV, v_off_fin = -19.673 uV 16:18:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.542 uVs 16:18:58 Integrated Voltage Measurement... 16:19:07 Voltage Offset Correction: v_off_ini = -23.667 uV, v_off_fin = -5.176 uV 16:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 147.788 uVs 16:19:07 Integrated Voltage Measurement... 16:19:16 Voltage Offset Correction: v_off_ini = -11.688 uV, v_off_fin = -18.274 uV 16:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.898 uVs 16:19:16 Integrated Voltage Measurement... 16:19:25 Voltage Offset Correction: v_off_ini = -19.885 uV, v_off_fin = -6.741 uV 16:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.275 uVs 16:19:29 I1Y Average and RMS of Measurements VT = -167.882 +- 8.952 uVs I1Y = -33.577 +- 1.791 uTm 16:19:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:19:37 Integrated Voltage Measurement... 16:19:46 Voltage Offset Correction: v_off_ini = -17.223 uV, v_off_fin = -39.898 uV 16:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.178 uVs 16:19:46 Integrated Voltage Measurement... 16:19:55 Voltage Offset Correction: v_off_ini = -25.880 uV, v_off_fin = -22.844 uV 16:19:55 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 30.375 uVs 16:19:55 Integrated Voltage Measurement... 16:20:04 Voltage Offset Correction: v_off_ini = -35.365 uV, v_off_fin = -39.587 uV 16:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.369 uVs 16:20:04 Integrated Voltage Measurement... 16:20:13 Voltage Offset Correction: v_off_ini = -32.473 uV, v_off_fin = -25.031 uV 16:20:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.227 uVs 16:20:13 Integrated Voltage Measurement... 16:20:22 Voltage Offset Correction: v_off_ini = -15.699 uV, v_off_fin = -35.233 uV 16:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.292 uVs 16:20:22 Integrated Voltage Measurement... 16:20:31 Voltage Offset Correction: v_off_ini = -30.045 uV, v_off_fin = -16.441 uV 16:20:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 28.511 uVs 16:20:34 I2X Average and RMS of Measurements VT = -39.159 +- 5.994 uVs I2X = 3.603 +- 0.551 uTm^2 16:20:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:20:41 Integrated Voltage Measurement... 16:20:50 Voltage Offset Correction: v_off_ini = -19.264 uV, v_off_fin = -9.888 uV 16:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.126 uVs 16:20:51 Integrated Voltage Measurement... 16:20:59 Voltage Offset Correction: v_off_ini = -33.249 uV, v_off_fin = -18.573 uV 16:21:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.924 uVs 16:21:00 Integrated Voltage Measurement... 16:21:09 Voltage Offset Correction: v_off_ini = -33.086 uV, v_off_fin = -27.084 uV 16:21:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.139 uVs 16:21:09 Integrated Voltage Measurement... 16:21:18 Voltage Offset Correction: v_off_ini = -19.879 uV, v_off_fin = -32.449 uV 16:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.800 uVs 16:21:18 Integrated Voltage Measurement... 16:21:27 Voltage Offset Correction: v_off_ini = -37.585 uV, v_off_fin = -30.542 uV 16:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.579 uVs 16:21:27 Integrated Voltage Measurement... 16:21:36 Voltage Offset Correction: v_off_ini = -33.771 uV, v_off_fin = -29.051 uV 16:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.039 uVs 16:21:38 I2Y Average and RMS of Measurements VT = -339.101 +- 4.722 uVs I2Y = -31.197 +- 0.434 uTm^2 16:21:43 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:21:47 Integrated Voltage Measurement... 16:21:56 Voltage Offset Correction: v_off_ini = -37.662 uV, v_off_fin = -37.557 uV 16:21:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.729 uVs 16:21:56 Integrated Voltage Measurement... 16:22:05 Voltage Offset Correction: v_off_ini = -26.330 uV, v_off_fin = -39.682 uV 16:22:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.541 uVs 16:22:05 Integrated Voltage Measurement... 16:22:14 Voltage Offset Correction: v_off_ini = -31.728 uV, v_off_fin = -29.432 uV 16:22:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.600 uVs 16:22:14 Integrated Voltage Measurement... 16:22:23 Voltage Offset Correction: v_off_ini = -33.354 uV, v_off_fin = -19.819 uV 16:22:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.902 uVs 16:22:23 Integrated Voltage Measurement... 16:22:32 Voltage Offset Correction: v_off_ini = -18.395 uV, v_off_fin = -22.293 uV 16:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.096 uVs 16:22:32 Integrated Voltage Measurement... 16:22:41 Voltage Offset Correction: v_off_ini = -14.597 uV, v_off_fin = -15.743 uV 16:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.741 uVs 16:22:45 I1X Average and RMS of Measurements VT = -53.768 +- 6.801 uVs I1X = 10.754 +- 1.361 uTm 16:22:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:22:52 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = -32.258 uV, v_off_fin = -41.193 uV 16:23:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.414 uVs 16:23:01 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = -49.200 uV, v_off_fin = -41.572 uV 16:23:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.329 uVs 16:23:10 Integrated Voltage Measurement... 16:23:19 Voltage Offset Correction: v_off_ini = -29.540 uV, v_off_fin = -37.790 uV 16:23:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.235 uVs 16:23:19 Integrated Voltage Measurement... 16:23:28 Voltage Offset Correction: v_off_ini = -24.916 uV, v_off_fin = -25.681 uV 16:23:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.075 uVs 16:23:28 Integrated Voltage Measurement... 16:23:37 Voltage Offset Correction: v_off_ini = -33.988 uV, v_off_fin = -38.848 uV 16:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.133 uVs 16:23:37 Integrated Voltage Measurement... 16:23:46 Voltage Offset Correction: v_off_ini = -29.177 uV, v_off_fin = -26.449 uV 16:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.857 uVs 16:23:50 I1Y Average and RMS of Measurements VT = -174.840 +- 1.663 uVs I1Y = -34.968 +- 0.333 uTm 16:23:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:23:58 Integrated Voltage Measurement... 16:24:07 Voltage Offset Correction: v_off_ini = -51.868 uV, v_off_fin = -49.314 uV 16:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.067 uVs 16:24:07 Integrated Voltage Measurement... 16:24:16 Voltage Offset Correction: v_off_ini = -48.702 uV, v_off_fin = -39.309 uV 16:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.071 uVs 16:24:16 Integrated Voltage Measurement... 16:24:25 Voltage Offset Correction: v_off_ini = -45.876 uV, v_off_fin = -48.119 uV 16:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.156 uVs 16:24:25 Integrated Voltage Measurement... 16:24:34 Voltage Offset Correction: v_off_ini = -56.503 uV, v_off_fin = -39.880 uV 16:24:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.718 uVs 16:24:34 Integrated Voltage Measurement... 16:24:43 Voltage Offset Correction: v_off_ini = -47.465 uV, v_off_fin = -52.410 uV 16:24:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -55.098 uVs 16:24:43 Integrated Voltage Measurement... 16:24:52 Voltage Offset Correction: v_off_ini = -48.299 uV, v_off_fin = -42.210 uV 16:24:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 43.605 uVs 16:24:55 I2X Average and RMS of Measurements VT = -47.786 +- 2.275 uVs I2X = 4.397 +- 0.209 uTm^2 16:25:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:25:02 Integrated Voltage Measurement... 16:25:11 Voltage Offset Correction: v_off_ini = -50.783 uV, v_off_fin = -50.113 uV 16:25:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.151 uVs 16:25:11 Integrated Voltage Measurement... 16:25:20 Voltage Offset Correction: v_off_ini = -40.799 uV, v_off_fin = -34.238 uV 16:25:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.330 uVs 16:25:20 Integrated Voltage Measurement... 16:25:29 Voltage Offset Correction: v_off_ini = -49.840 uV, v_off_fin = -52.340 uV 16:25:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.559 uVs 16:25:29 Integrated Voltage Measurement... 16:25:38 Voltage Offset Correction: v_off_ini = -55.184 uV, v_off_fin = -52.790 uV 16:25:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.356 uVs 16:25:38 Integrated Voltage Measurement... 16:25:47 Voltage Offset Correction: v_off_ini = -39.490 uV, v_off_fin = -41.046 uV 16:25:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.590 uVs 16:25:47 Integrated Voltage Measurement... 16:25:56 Voltage Offset Correction: v_off_ini = -42.592 uV, v_off_fin = -49.712 uV 16:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.925 uVs 16:25:59 I2Y Average and RMS of Measurements VT = -346.152 +- 4.672 uVs I2Y = -31.846 +- 0.430 uTm^2 16:26:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:08 Integrated Voltage Measurement... 16:26:17 Voltage Offset Correction: v_off_ini = -53.361 uV, v_off_fin = -53.029 uV 16:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.768 uVs 16:26:17 Integrated Voltage Measurement... 16:26:26 Voltage Offset Correction: v_off_ini = -30.320 uV, v_off_fin = -31.514 uV 16:26:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 40.688 uVs 16:26:26 Integrated Voltage Measurement... 16:26:35 Voltage Offset Correction: v_off_ini = -33.320 uV, v_off_fin = -40.896 uV 16:26:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.762 uVs 16:26:35 Integrated Voltage Measurement... 16:26:44 Voltage Offset Correction: v_off_ini = -42.704 uV, v_off_fin = -52.118 uV 16:26:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.685 uVs 16:26:44 Integrated Voltage Measurement... 16:26:53 Voltage Offset Correction: v_off_ini = -51.926 uV, v_off_fin = -50.699 uV 16:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.814 uVs 16:26:53 Integrated Voltage Measurement... 16:27:02 Voltage Offset Correction: v_off_ini = -48.873 uV, v_off_fin = -44.964 uV 16:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.762 uVs 16:27:06 I1X Average and RMS of Measurements VT = -56.747 +- 11.899 uVs I1X = 11.349 +- 2.380 uTm 16:27:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:13 Integrated Voltage Measurement... 16:27:22 Voltage Offset Correction: v_off_ini = -58.326 uV, v_off_fin = -55.997 uV 16:27:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.634 uVs 16:27:22 Integrated Voltage Measurement... 16:27:31 Voltage Offset Correction: v_off_ini = -55.964 uV, v_off_fin = -46.886 uV 16:27:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.785 uVs 16:27:31 Integrated Voltage Measurement... 16:27:40 Voltage Offset Correction: v_off_ini = -49.503 uV, v_off_fin = -59.520 uV 16:27:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.519 uVs 16:27:40 Integrated Voltage Measurement... 16:27:49 Voltage Offset Correction: v_off_ini = -39.085 uV, v_off_fin = -29.230 uV 16:27:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.577 uVs 16:27:49 Integrated Voltage Measurement... 16:27:58 Voltage Offset Correction: v_off_ini = -38.644 uV, v_off_fin = -51.497 uV 16:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.049 uVs 16:27:58 Integrated Voltage Measurement... 16:28:07 Voltage Offset Correction: v_off_ini = -43.172 uV, v_off_fin = -31.822 uV 16:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.359 uVs 16:28:11 I1Y Average and RMS of Measurements VT = -173.154 +- 6.105 uVs I1Y = -34.631 +- 1.221 uTm 16:28:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:19 Integrated Voltage Measurement... 16:28:28 Voltage Offset Correction: v_off_ini = -35.044 uV, v_off_fin = -55.843 uV 16:28:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.082 uVs 16:28:28 Integrated Voltage Measurement... 16:28:37 Voltage Offset Correction: v_off_ini = -41.838 uV, v_off_fin = -34.549 uV 16:28:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.256 uVs 16:28:37 Integrated Voltage Measurement... 16:28:46 Voltage Offset Correction: v_off_ini = -35.199 uV, v_off_fin = -50.215 uV 16:28:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.807 uVs 16:28:46 Integrated Voltage Measurement... 16:28:55 Voltage Offset Correction: v_off_ini = -37.457 uV, v_off_fin = -34.351 uV 16:28:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.404 uVs 16:28:55 Integrated Voltage Measurement... 16:29:04 Voltage Offset Correction: v_off_ini = -29.981 uV, v_off_fin = -46.779 uV 16:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.087 uVs 16:29:04 Integrated Voltage Measurement... 16:29:13 Voltage Offset Correction: v_off_ini = -41.680 uV, v_off_fin = -32.821 uV 16:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.562 uVs 16:29:15 I2X Average and RMS of Measurements VT = -56.533 +- 6.729 uVs I2X = 5.201 +- 0.619 uTm^2 16:29:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:23 Integrated Voltage Measurement... 16:29:32 Voltage Offset Correction: v_off_ini = -39.261 uV, v_off_fin = -52.249 uV 16:29:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.841 uVs 16:29:32 Integrated Voltage Measurement... 16:29:41 Voltage Offset Correction: v_off_ini = -40.560 uV, v_off_fin = -42.644 uV 16:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.328 uVs 16:29:41 Integrated Voltage Measurement... 16:29:50 Voltage Offset Correction: v_off_ini = -40.540 uV, v_off_fin = -41.531 uV 16:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.530 uVs 16:29:50 Integrated Voltage Measurement... 16:29:59 Voltage Offset Correction: v_off_ini = -44.152 uV, v_off_fin = -32.048 uV 16:29:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 349.394 uVs 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = -31.600 uV, v_off_fin = -43.132 uV 16:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.283 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = -41.065 uV, v_off_fin = -36.322 uV 16:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.358 uVs 16:30:20 I2Y Average and RMS of Measurements VT = -350.789 +- 3.212 uVs I2Y = -32.273 +- 0.295 uTm^2 16:30:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:30:29 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = -35.106 uV, v_off_fin = -30.256 uV 16:30:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -62.067 uVs 16:30:38 Integrated Voltage Measurement... 16:30:47 Voltage Offset Correction: v_off_ini = -35.224 uV, v_off_fin = -30.604 uV 16:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.820 uVs 16:30:47 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = -37.064 uV, v_off_fin = -45.677 uV 16:30:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.280 uVs 16:30:56 Integrated Voltage Measurement... 16:31:05 Voltage Offset Correction: v_off_ini = -31.454 uV, v_off_fin = -20.975 uV 16:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.737 uVs 16:31:05 Integrated Voltage Measurement... 16:31:14 Voltage Offset Correction: v_off_ini = -41.690 uV, v_off_fin = -29.015 uV 16:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.946 uVs 16:31:14 Integrated Voltage Measurement... 16:31:23 Voltage Offset Correction: v_off_ini = -25.892 uV, v_off_fin = -22.293 uV 16:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.751 uVs 16:31:27 I1X Average and RMS of Measurements VT = -61.934 +- 4.250 uVs I1X = 12.388 +- 0.851 uTm 16:31:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:31:34 Integrated Voltage Measurement... 16:31:43 Voltage Offset Correction: v_off_ini = -40.721 uV, v_off_fin = -33.779 uV 16:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -176.656 uVs 16:31:43 Integrated Voltage Measurement... 16:31:52 Voltage Offset Correction: v_off_ini = -20.233 uV, v_off_fin = -13.881 uV 16:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.622 uVs 16:31:52 Integrated Voltage Measurement... 16:32:01 Voltage Offset Correction: v_off_ini = -31.946 uV, v_off_fin = -37.729 uV 16:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.937 uVs 16:32:01 Integrated Voltage Measurement... 16:32:10 Voltage Offset Correction: v_off_ini = -35.375 uV, v_off_fin = -19.113 uV 16:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.591 uVs 16:32:10 Integrated Voltage Measurement... 16:32:18 Voltage Offset Correction: v_off_ini = -37.197 uV, v_off_fin = -43.434 uV 16:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.416 uVs 16:32:19 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = -19.975 uV, v_off_fin = -9.996 uV 16:32:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.779 uVs 16:32:32 I1Y Average and RMS of Measurements VT = -170.333 +- 6.122 uVs I1Y = -34.067 +- 1.225 uTm 16:32:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:32:39 Integrated Voltage Measurement... 16:32:48 Voltage Offset Correction: v_off_ini = -22.487 uV, v_off_fin = -42.470 uV 16:32:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.820 uVs 16:32:48 Integrated Voltage Measurement... 16:32:57 Voltage Offset Correction: v_off_ini = -34.392 uV, v_off_fin = -42.106 uV 16:32:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.588 uVs 16:32:57 Integrated Voltage Measurement... 16:33:06 Voltage Offset Correction: v_off_ini = -52.425 uV, v_off_fin = -54.441 uV 16:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.537 uVs 16:33:06 Integrated Voltage Measurement... 16:33:15 Voltage Offset Correction: v_off_ini = -33.766 uV, v_off_fin = -42.349 uV 16:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.262 uVs 16:33:15 Integrated Voltage Measurement... 16:33:24 Voltage Offset Correction: v_off_ini = -46.821 uV, v_off_fin = -51.127 uV 16:33:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.084 uVs 16:33:24 Integrated Voltage Measurement... 16:33:33 Voltage Offset Correction: v_off_ini = -48.101 uV, v_off_fin = -32.570 uV 16:33:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.572 uVs 16:33:36 I2X Average and RMS of Measurements VT = -59.477 +- 6.250 uVs I2X = 5.472 +- 0.575 uTm^2 16:33:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:33:44 Integrated Voltage Measurement... 16:33:53 Voltage Offset Correction: v_off_ini = -39.234 uV, v_off_fin = -41.904 uV 16:33:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.175 uVs 16:33:53 Integrated Voltage Measurement... 16:34:02 Voltage Offset Correction: v_off_ini = -40.617 uV, v_off_fin = -37.860 uV 16:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.688 uVs 16:34:02 Integrated Voltage Measurement... 16:34:11 Voltage Offset Correction: v_off_ini = -48.678 uV, v_off_fin = -54.476 uV 16:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.580 uVs 16:34:11 Integrated Voltage Measurement... 16:34:20 Voltage Offset Correction: v_off_ini = -36.642 uV, v_off_fin = -54.058 uV 16:34:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 356.645 uVs 16:34:20 Integrated Voltage Measurement... 16:34:29 Voltage Offset Correction: v_off_ini = -53.870 uV, v_off_fin = -58.595 uV 16:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.681 uVs 16:34:29 Integrated Voltage Measurement... 16:34:38 Voltage Offset Correction: v_off_ini = -44.464 uV, v_off_fin = -49.164 uV 16:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.129 uVs 16:34:40 I2Y Average and RMS of Measurements VT = -346.483 +- 4.384 uVs I2Y = -31.877 +- 0.403 uTm^2 16:34:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:34:49 Integrated Voltage Measurement... 16:34:58 Voltage Offset Correction: v_off_ini = -40.440 uV, v_off_fin = -42.596 uV 16:34:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.774 uVs 16:34:58 Integrated Voltage Measurement... 16:35:07 Voltage Offset Correction: v_off_ini = -49.161 uV, v_off_fin = -29.165 uV 16:35:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.279 uVs 16:35:07 Integrated Voltage Measurement... 16:35:16 Voltage Offset Correction: v_off_ini = -45.225 uV, v_off_fin = -50.412 uV 16:35:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.220 uVs 16:35:16 Integrated Voltage Measurement... 16:35:25 Voltage Offset Correction: v_off_ini = -26.904 uV, v_off_fin = -18.211 uV 16:35:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.355 uVs 16:35:25 Integrated Voltage Measurement... 16:35:34 Voltage Offset Correction: v_off_ini = -32.502 uV, v_off_fin = -22.898 uV 16:35:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.150 uVs 16:35:34 Integrated Voltage Measurement... 16:35:43 Voltage Offset Correction: v_off_ini = -35.423 uV, v_off_fin = -34.250 uV 16:35:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.851 uVs 16:35:47 I1X Average and RMS of Measurements VT = -67.105 +- 8.456 uVs I1X = 13.421 +- 1.691 uTm 16:35:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:35:54 Integrated Voltage Measurement... 16:36:03 Voltage Offset Correction: v_off_ini = -42.341 uV, v_off_fin = -46.868 uV 16:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.148 uVs 16:36:03 Integrated Voltage Measurement... 16:36:12 Voltage Offset Correction: v_off_ini = -38.952 uV, v_off_fin = -36.320 uV 16:36:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 179.067 uVs 16:36:12 Integrated Voltage Measurement... 16:36:21 Voltage Offset Correction: v_off_ini = -47.046 uV, v_off_fin = -48.227 uV 16:36:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.527 uVs 16:36:21 Integrated Voltage Measurement... 16:36:30 Voltage Offset Correction: v_off_ini = -42.130 uV, v_off_fin = -41.177 uV 16:36:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.826 uVs 16:36:30 Integrated Voltage Measurement... 16:36:39 Voltage Offset Correction: v_off_ini = -55.608 uV, v_off_fin = -51.521 uV 16:36:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.031 uVs 16:36:39 Integrated Voltage Measurement... 16:36:48 Voltage Offset Correction: v_off_ini = -49.456 uV, v_off_fin = -25.077 uV 16:36:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.421 uVs 16:36:52 I1Y Average and RMS of Measurements VT = -174.837 +- 6.626 uVs I1Y = -34.968 +- 1.325 uTm 16:36:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:37:00 Integrated Voltage Measurement... 16:37:09 Voltage Offset Correction: v_off_ini = -52.641 uV, v_off_fin = -52.085 uV 16:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.071 uVs 16:37:09 Integrated Voltage Measurement... 16:37:18 Voltage Offset Correction: v_off_ini = -53.711 uV, v_off_fin = -49.263 uV 16:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.216 uVs 16:37:18 Integrated Voltage Measurement... 16:37:27 Voltage Offset Correction: v_off_ini = -54.718 uV, v_off_fin = -48.620 uV 16:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.998 uVs 16:37:27 Integrated Voltage Measurement... 16:37:36 Voltage Offset Correction: v_off_ini = -41.059 uV, v_off_fin = -33.415 uV 16:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.836 uVs 16:37:36 Integrated Voltage Measurement... 16:37:45 Voltage Offset Correction: v_off_ini = -36.436 uV, v_off_fin = -53.033 uV 16:37:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.304 uVs 16:37:45 Integrated Voltage Measurement... 16:37:54 Voltage Offset Correction: v_off_ini = -38.366 uV, v_off_fin = -33.430 uV 16:37:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.269 uVs 16:37:56 I2X Average and RMS of Measurements VT = -71.116 +- 4.976 uVs I2X = 6.543 +- 0.458 uTm^2 16:38:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:38:04 Integrated Voltage Measurement... 16:38:13 Voltage Offset Correction: v_off_ini = -36.607 uV, v_off_fin = -40.257 uV 16:38:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.022 uVs 16:38:13 Integrated Voltage Measurement... 16:38:22 Voltage Offset Correction: v_off_ini = -40.132 uV, v_off_fin = -41.009 uV 16:38:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.635 uVs 16:38:22 Integrated Voltage Measurement... 16:38:31 Voltage Offset Correction: v_off_ini = -60.126 uV, v_off_fin = -54.725 uV 16:38:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.439 uVs 16:38:31 Integrated Voltage Measurement... 16:38:40 Voltage Offset Correction: v_off_ini = -59.741 uV, v_off_fin = -52.496 uV 16:38:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.884 uVs 16:38:40 Integrated Voltage Measurement... 16:38:49 Voltage Offset Correction: v_off_ini = -58.742 uV, v_off_fin = -57.637 uV 16:38:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.381 uVs 16:38:49 Integrated Voltage Measurement... 16:38:58 Voltage Offset Correction: v_off_ini = -48.606 uV, v_off_fin = -62.799 uV 16:38:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.901 uVs 16:39:00 I2Y Average and RMS of Measurements VT = -343.710 +- 5.978 uVs I2Y = -31.621 +- 0.550 uTm^2 16:39:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:39:12 Integrated Voltage Measurement... 16:39:21 Voltage Offset Correction: v_off_ini = -46.882 uV, v_off_fin = -55.199 uV 16:39:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.933 uVs 16:39:21 Integrated Voltage Measurement... 16:39:30 Voltage Offset Correction: v_off_ini = -58.063 uV, v_off_fin = -49.332 uV 16:39:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.857 uVs 16:39:30 Integrated Voltage Measurement... 16:39:39 Voltage Offset Correction: v_off_ini = -68.249 uV, v_off_fin = -71.003 uV 16:39:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.324 uVs 16:39:39 Integrated Voltage Measurement... 16:39:48 Voltage Offset Correction: v_off_ini = -57.311 uV, v_off_fin = -48.975 uV 16:39:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.517 uVs 16:39:48 Integrated Voltage Measurement... 16:39:57 Voltage Offset Correction: v_off_ini = -54.023 uV, v_off_fin = -61.342 uV 16:39:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -55.579 uVs 16:39:57 Integrated Voltage Measurement... 16:40:06 Voltage Offset Correction: v_off_ini = -68.281 uV, v_off_fin = -54.036 uV 16:40:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.388 uVs 16:40:11 I1X Average and RMS of Measurements VT = -41.933 +- 5.550 uVs I1X = 8.387 +- 1.110 uTm 16:40:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:40:17 Integrated Voltage Measurement... 16:40:26 Voltage Offset Correction: v_off_ini = -49.290 uV, v_off_fin = -61.756 uV 16:40:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.390 uVs 16:40:26 Integrated Voltage Measurement... 16:40:35 Voltage Offset Correction: v_off_ini = -58.930 uV, v_off_fin = -48.765 uV 16:40:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.921 uVs 16:40:35 Integrated Voltage Measurement... 16:40:44 Voltage Offset Correction: v_off_ini = -50.439 uV, v_off_fin = -48.915 uV 16:40:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.005 uVs 16:40:44 Integrated Voltage Measurement... 16:40:53 Voltage Offset Correction: v_off_ini = -52.323 uV, v_off_fin = -37.663 uV 16:40:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.059 uVs 16:40:53 Integrated Voltage Measurement... 16:41:02 Voltage Offset Correction: v_off_ini = -40.322 uV, v_off_fin = -46.892 uV 16:41:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.811 uVs 16:41:02 Integrated Voltage Measurement... 16:41:11 Voltage Offset Correction: v_off_ini = -54.406 uV, v_off_fin = -51.248 uV 16:41:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.188 uVs 16:41:15 I1Y Average and RMS of Measurements VT = -172.395 +- 6.731 uVs I1Y = -34.479 +- 1.346 uTm 16:41:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:41:21 Integrated Voltage Measurement... 16:41:29 Voltage Offset Correction: v_off_ini = -87.637 uV, v_off_fin = -75.925 uV 16:41:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.850 uVs 16:41:30 Integrated Voltage Measurement... 16:41:38 Voltage Offset Correction: v_off_ini = -70.726 uV, v_off_fin = -63.171 uV 16:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.035 uVs 16:41:39 Integrated Voltage Measurement... 16:41:48 Voltage Offset Correction: v_off_ini = -69.457 uV, v_off_fin = -80.605 uV 16:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.295 uVs 16:41:48 Integrated Voltage Measurement... 16:41:57 Voltage Offset Correction: v_off_ini = -64.512 uV, v_off_fin = -53.090 uV 16:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.234 uVs 16:41:57 Integrated Voltage Measurement... 16:42:06 Voltage Offset Correction: v_off_ini = -53.741 uV, v_off_fin = -67.441 uV 16:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.677 uVs 16:42:06 Integrated Voltage Measurement... 16:42:15 Voltage Offset Correction: v_off_ini = -63.414 uV, v_off_fin = -61.712 uV 16:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.539 uVs 16:42:17 I2X Average and RMS of Measurements VT = -49.272 +- 8.383 uVs I2X = 4.533 +- 0.771 uTm^2 16:42:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = -69.907 uV, v_off_fin = -76.619 uV 16:42:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.636 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = -68.500 uV, v_off_fin = -64.760 uV 16:42:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.930 uVs 16:42:40 Integrated Voltage Measurement... 16:42:49 Voltage Offset Correction: v_off_ini = -62.625 uV, v_off_fin = -65.030 uV 16:42:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.963 uVs 16:42:49 Integrated Voltage Measurement... 16:42:58 Voltage Offset Correction: v_off_ini = -64.597 uV, v_off_fin = -67.956 uV 16:42:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.256 uVs 16:42:58 Integrated Voltage Measurement... 16:43:07 Voltage Offset Correction: v_off_ini = -78.603 uV, v_off_fin = -74.599 uV 16:43:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.490 uVs 16:43:07 Integrated Voltage Measurement... 16:43:16 Voltage Offset Correction: v_off_ini = -73.825 uV, v_off_fin = -75.566 uV 16:43:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.115 uVs 16:43:19 I2Y Average and RMS of Measurements VT = -339.232 +- 8.355 uVs I2Y = -31.209 +- 0.769 uTm^2 16:43:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:43:27 Integrated Voltage Measurement... 16:43:36 Voltage Offset Correction: v_off_ini = -70.640 uV, v_off_fin = -96.756 uV 16:43:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.771 uVs 16:43:36 Integrated Voltage Measurement... 16:43:45 Voltage Offset Correction: v_off_ini = -78.690 uV, v_off_fin = -72.839 uV 16:43:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.687 uVs 16:43:45 Integrated Voltage Measurement... 16:43:54 Voltage Offset Correction: v_off_ini = -76.001 uV, v_off_fin = -82.593 uV 16:43:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.791 uVs 16:43:54 Integrated Voltage Measurement... 16:44:03 Voltage Offset Correction: v_off_ini = -76.627 uV, v_off_fin = -68.208 uV 16:44:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.817 uVs 16:44:03 Integrated Voltage Measurement... 16:44:12 Voltage Offset Correction: v_off_ini = -74.531 uV, v_off_fin = -84.116 uV 16:44:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.527 uVs 16:44:12 Integrated Voltage Measurement... 16:44:21 Voltage Offset Correction: v_off_ini = -79.152 uV, v_off_fin = -70.542 uV 16:44:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.601 uVs 16:44:25 I1X Average and RMS of Measurements VT = -54.532 +- 11.533 uVs I1X = 10.906 +- 2.307 uTm 16:44:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:44:32 Integrated Voltage Measurement... 16:44:41 Voltage Offset Correction: v_off_ini = -43.575 uV, v_off_fin = -67.757 uV 16:44:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.051 uVs 16:44:41 Integrated Voltage Measurement... 16:44:50 Voltage Offset Correction: v_off_ini = -73.158 uV, v_off_fin = -49.658 uV 16:44:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.517 uVs 16:44:50 Integrated Voltage Measurement... 16:44:59 Voltage Offset Correction: v_off_ini = -65.223 uV, v_off_fin = -62.434 uV 16:44:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.095 uVs 16:44:59 Integrated Voltage Measurement... 16:45:08 Voltage Offset Correction: v_off_ini = -54.798 uV, v_off_fin = -44.536 uV 16:45:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.262 uVs 16:45:08 Integrated Voltage Measurement... 16:45:17 Voltage Offset Correction: v_off_ini = -63.696 uV, v_off_fin = -63.926 uV 16:45:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.051 uVs 16:45:17 Integrated Voltage Measurement... 16:45:26 Voltage Offset Correction: v_off_ini = -62.928 uV, v_off_fin = -58.096 uV 16:45:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.266 uVs 16:45:30 I1Y Average and RMS of Measurements VT = -171.541 +- 3.971 uVs I1Y = -34.308 +- 0.794 uTm 16:45:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:45:36 Integrated Voltage Measurement... 16:45:45 Voltage Offset Correction: v_off_ini = -71.656 uV, v_off_fin = -77.529 uV 16:45:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.873 uVs 16:45:45 Integrated Voltage Measurement... 16:45:54 Voltage Offset Correction: v_off_ini = -77.163 uV, v_off_fin = -66.179 uV 16:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.472 uVs 16:45:54 Integrated Voltage Measurement... 16:46:03 Voltage Offset Correction: v_off_ini = -69.892 uV, v_off_fin = -84.846 uV 16:46:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.020 uVs 16:46:03 Integrated Voltage Measurement... 16:46:12 Voltage Offset Correction: v_off_ini = -78.862 uV, v_off_fin = -72.945 uV 16:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.731 uVs 16:46:12 Integrated Voltage Measurement... 16:46:21 Voltage Offset Correction: v_off_ini = -81.899 uV, v_off_fin = -84.569 uV 16:46:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.360 uVs 16:46:21 Integrated Voltage Measurement... 16:46:30 Voltage Offset Correction: v_off_ini = -71.116 uV, v_off_fin = -74.384 uV 16:46:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.132 uVs 16:46:32 I2X Average and RMS of Measurements VT = -52.098 +- 6.222 uVs I2X = 4.793 +- 0.572 uTm^2 16:46:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:46:37 Integrated Voltage Measurement... 16:46:46 Voltage Offset Correction: v_off_ini = -76.305 uV, v_off_fin = -80.107 uV 16:46:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.531 uVs 16:46:46 Integrated Voltage Measurement... 16:46:55 Voltage Offset Correction: v_off_ini = -90.125 uV, v_off_fin = -90.023 uV 16:46:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.223 uVs 16:46:55 Integrated Voltage Measurement... 16:47:04 Voltage Offset Correction: v_off_ini = -78.934 uV, v_off_fin = -102.877 uV 16:47:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.126 uVs 16:47:04 Integrated Voltage Measurement... 16:47:13 Voltage Offset Correction: v_off_ini = -86.976 uV, v_off_fin = -89.379 uV 16:47:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.004 uVs 16:47:13 Integrated Voltage Measurement... 16:47:22 Voltage Offset Correction: v_off_ini = -96.491 uV, v_off_fin = -92.006 uV 16:47:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.036 uVs 16:47:22 Integrated Voltage Measurement... 16:47:31 Voltage Offset Correction: v_off_ini = -97.053 uV, v_off_fin = -83.960 uV 16:47:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.999 uVs 16:47:34 I2Y Average and RMS of Measurements VT = -347.987 +- 11.399 uVs I2Y = -32.015 +- 1.049 uTm^2 16:47:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:42 Integrated Voltage Measurement... 16:47:51 Voltage Offset Correction: v_off_ini = -90.623 uV, v_off_fin = -94.028 uV 16:47:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -58.373 uVs 16:47:51 Integrated Voltage Measurement... 16:48:00 Voltage Offset Correction: v_off_ini = -95.541 uV, v_off_fin = -83.618 uV 16:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.776 uVs 16:48:00 Integrated Voltage Measurement... 16:48:09 Voltage Offset Correction: v_off_ini = -100.610 uV, v_off_fin = -85.042 uV 16:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.710 uVs 16:48:09 Integrated Voltage Measurement... 16:48:18 Voltage Offset Correction: v_off_ini = -85.396 uV, v_off_fin = -76.050 uV 16:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.919 uVs 16:48:18 Integrated Voltage Measurement... 16:48:27 Voltage Offset Correction: v_off_ini = -106.352 uV, v_off_fin = -87.602 uV 16:48:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.374 uVs 16:48:27 Integrated Voltage Measurement... 16:48:36 Voltage Offset Correction: v_off_ini = -94.715 uV, v_off_fin = -92.691 uV 16:48:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.222 uVs 16:48:40 I1X Average and RMS of Measurements VT = -48.562 +- 3.967 uVs I1X = 9.713 +- 0.793 uTm 16:48:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:47 Integrated Voltage Measurement... 16:48:56 Voltage Offset Correction: v_off_ini = -85.904 uV, v_off_fin = -94.282 uV 16:48:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.691 uVs 16:48:56 Integrated Voltage Measurement... 16:49:05 Voltage Offset Correction: v_off_ini = -106.076 uV, v_off_fin = -88.168 uV 16:49:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.924 uVs 16:49:05 Integrated Voltage Measurement... 16:49:14 Voltage Offset Correction: v_off_ini = -93.954 uV, v_off_fin = -99.312 uV 16:49:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.163 uVs 16:49:14 Integrated Voltage Measurement... 16:49:23 Voltage Offset Correction: v_off_ini = -103.108 uV, v_off_fin = -91.074 uV 16:49:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.001 uVs 16:49:23 Integrated Voltage Measurement... 16:49:32 Voltage Offset Correction: v_off_ini = -112.302 uV, v_off_fin = -114.188 uV 16:49:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.615 uVs 16:49:32 Integrated Voltage Measurement... 16:49:41 Voltage Offset Correction: v_off_ini = -99.975 uV, v_off_fin = -99.962 uV 16:49:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.205 uVs 16:49:45 I1Y Average and RMS of Measurements VT = -166.433 +- 6.136 uVs I1Y = -33.287 +- 1.227 uTm 16:49:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:51 Integrated Voltage Measurement... 16:50:00 Voltage Offset Correction: v_off_ini = -92.073 uV, v_off_fin = -95.609 uV 16:50:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.249 uVs 16:50:00 Integrated Voltage Measurement... 16:50:09 Voltage Offset Correction: v_off_ini = -98.677 uV, v_off_fin = -91.068 uV 16:50:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.384 uVs 16:50:09 Integrated Voltage Measurement... 16:50:18 Voltage Offset Correction: v_off_ini = -104.453 uV, v_off_fin = -116.502 uV 16:50:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.535 uVs 16:50:18 Integrated Voltage Measurement... 16:50:27 Voltage Offset Correction: v_off_ini = -86.576 uV, v_off_fin = -93.532 uV 16:50:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.687 uVs 16:50:27 Integrated Voltage Measurement... 16:50:36 Voltage Offset Correction: v_off_ini = -120.123 uV, v_off_fin = -122.271 uV 16:50:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.911 uVs 16:50:36 Integrated Voltage Measurement... 16:50:45 Voltage Offset Correction: v_off_ini = -105.596 uV, v_off_fin = -103.463 uV 16:50:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.496 uVs 16:50:47 I2X Average and RMS of Measurements VT = -51.877 +- 4.554 uVs I2X = 4.773 +- 0.419 uTm^2 16:50:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:52 Integrated Voltage Measurement... 16:51:01 Voltage Offset Correction: v_off_ini = -107.545 uV, v_off_fin = -107.713 uV 16:51:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.871 uVs 16:51:01 Integrated Voltage Measurement... 16:51:10 Voltage Offset Correction: v_off_ini = -96.474 uV, v_off_fin = -104.601 uV 16:51:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.622 uVs 16:51:10 Integrated Voltage Measurement... 16:51:19 Voltage Offset Correction: v_off_ini = -105.101 uV, v_off_fin = -103.852 uV 16:51:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.752 uVs 16:51:19 Integrated Voltage Measurement... 16:51:28 Voltage Offset Correction: v_off_ini = -118.571 uV, v_off_fin = -110.198 uV 16:51:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.427 uVs 16:51:28 Integrated Voltage Measurement... 16:51:37 Voltage Offset Correction: v_off_ini = -107.417 uV, v_off_fin = -109.940 uV 16:51:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.034 uVs 16:51:37 Integrated Voltage Measurement... 16:51:46 Voltage Offset Correction: v_off_ini = -104.576 uV, v_off_fin = -112.194 uV 16:51:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.335 uVs 16:51:49 I2Y Average and RMS of Measurements VT = -343.507 +- 7.319 uVs I2Y = -31.603 +- 0.673 uTm^2 16:51:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:51:57 Integrated Voltage Measurement... 16:52:06 Voltage Offset Correction: v_off_ini = -128.185 uV, v_off_fin = -123.056 uV 16:52:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.099 uVs 16:52:06 Integrated Voltage Measurement... 16:52:15 Voltage Offset Correction: v_off_ini = -125.134 uV, v_off_fin = -120.152 uV 16:52:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.222 uVs 16:52:15 Integrated Voltage Measurement... 16:52:24 Voltage Offset Correction: v_off_ini = -120.052 uV, v_off_fin = -122.119 uV 16:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.598 uVs 16:52:24 Integrated Voltage Measurement... 16:52:33 Voltage Offset Correction: v_off_ini = -117.424 uV, v_off_fin = -112.056 uV 16:52:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.867 uVs 16:52:33 Integrated Voltage Measurement... 16:52:42 Voltage Offset Correction: v_off_ini = -103.851 uV, v_off_fin = -106.271 uV 16:52:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.384 uVs 16:52:42 Integrated Voltage Measurement... 16:52:51 Voltage Offset Correction: v_off_ini = -102.350 uV, v_off_fin = -99.216 uV 16:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.613 uVs 16:52:56 I1X Average and RMS of Measurements VT = -54.297 +- 1.071 uVs I1X = 10.860 +- 0.214 uTm 16:52:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:53:02 Integrated Voltage Measurement... 16:53:11 Voltage Offset Correction: v_off_ini = -111.106 uV, v_off_fin = -125.578 uV 16:53:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.535 uVs 16:53:11 Integrated Voltage Measurement... 16:53:20 Voltage Offset Correction: v_off_ini = -108.272 uV, v_off_fin = -101.356 uV 16:53:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 174.345 uVs 16:53:20 Integrated Voltage Measurement... 16:53:29 Voltage Offset Correction: v_off_ini = -114.484 uV, v_off_fin = -131.760 uV 16:53:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.656 uVs 16:53:29 Integrated Voltage Measurement... 16:53:38 Voltage Offset Correction: v_off_ini = -121.840 uV, v_off_fin = -111.313 uV 16:53:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.945 uVs 16:53:38 Integrated Voltage Measurement... 16:53:47 Voltage Offset Correction: v_off_ini = -107.703 uV, v_off_fin = -126.822 uV 16:53:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.923 uVs 16:53:47 Integrated Voltage Measurement... 16:53:56 Voltage Offset Correction: v_off_ini = -129.579 uV, v_off_fin = -114.627 uV 16:53:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.549 uVs 16:54:01 I1Y Average and RMS of Measurements VT = -174.325 +- 3.455 uVs I1Y = -34.863 +- 0.692 uTm 16:54:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:54:06 Integrated Voltage Measurement... 16:54:15 Voltage Offset Correction: v_off_ini = -132.588 uV, v_off_fin = -132.414 uV 16:54:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.523 uVs 16:54:15 Integrated Voltage Measurement... 16:54:24 Voltage Offset Correction: v_off_ini = -117.474 uV, v_off_fin = -109.144 uV 16:54:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.468 uVs 16:54:24 Integrated Voltage Measurement... 16:54:33 Voltage Offset Correction: v_off_ini = -127.407 uV, v_off_fin = -126.278 uV 16:54:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.578 uVs 16:54:33 Integrated Voltage Measurement... 16:54:42 Voltage Offset Correction: v_off_ini = -114.931 uV, v_off_fin = -108.648 uV 16:54:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 57.049 uVs 16:54:42 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = -109.812 uV, v_off_fin = -127.066 uV 16:54:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.000 uVs 16:54:51 Integrated Voltage Measurement... 16:55:00 Voltage Offset Correction: v_off_ini = -107.642 uV, v_off_fin = -114.677 uV 16:55:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.954 uVs 16:55:02 I2X Average and RMS of Measurements VT = -49.929 +- 1.333 uVs I2X = 4.594 +- 0.123 uTm^2 16:55:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:55:07 Integrated Voltage Measurement... 16:55:16 Voltage Offset Correction: v_off_ini = -121.208 uV, v_off_fin = -120.776 uV 16:55:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.946 uVs 16:55:16 Integrated Voltage Measurement... 16:55:25 Voltage Offset Correction: v_off_ini = -105.767 uV, v_off_fin = -106.938 uV 16:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.624 uVs 16:55:25 Integrated Voltage Measurement... 16:55:34 Voltage Offset Correction: v_off_ini = -111.483 uV, v_off_fin = -101.301 uV 16:55:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.700 uVs 16:55:35 Integrated Voltage Measurement... 16:55:43 Voltage Offset Correction: v_off_ini = -99.983 uV, v_off_fin = -102.523 uV 16:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.740 uVs 16:55:44 Integrated Voltage Measurement... 16:55:53 Voltage Offset Correction: v_off_ini = -102.600 uV, v_off_fin = -97.554 uV 16:55:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.949 uVs 16:55:53 Integrated Voltage Measurement... 16:56:02 Voltage Offset Correction: v_off_ini = -99.720 uV, v_off_fin = -103.628 uV 16:56:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.478 uVs 16:56:04 I2Y Average and RMS of Measurements VT = -349.906 +- 7.576 uVs I2Y = -32.191 +- 0.697 uTm^2 16:56:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:56:12 Integrated Voltage Measurement... 16:56:21 Voltage Offset Correction: v_off_ini = -96.233 uV, v_off_fin = -104.152 uV 16:56:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -52.896 uVs 16:56:21 Integrated Voltage Measurement... 16:56:30 Voltage Offset Correction: v_off_ini = -107.512 uV, v_off_fin = -106.885 uV 16:56:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.757 uVs 16:56:30 Integrated Voltage Measurement... 16:56:39 Voltage Offset Correction: v_off_ini = -104.164 uV, v_off_fin = -108.982 uV 16:56:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.136 uVs 16:56:39 Integrated Voltage Measurement... 16:56:48 Voltage Offset Correction: v_off_ini = -119.936 uV, v_off_fin = -98.652 uV 16:56:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.797 uVs 16:56:48 Integrated Voltage Measurement... 16:56:57 Voltage Offset Correction: v_off_ini = -79.181 uV, v_off_fin = -92.822 uV 16:56:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -52.786 uVs 16:56:57 Integrated Voltage Measurement... 16:57:06 Voltage Offset Correction: v_off_ini = -90.678 uV, v_off_fin = -95.044 uV 16:57:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.770 uVs 16:57:11 I1X Average and RMS of Measurements VT = -52.524 +- 3.567 uVs I1X = 10.506 +- 0.713 uTm 16:57:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:57:17 Integrated Voltage Measurement... 16:57:26 Voltage Offset Correction: v_off_ini = -104.868 uV, v_off_fin = -111.925 uV 16:57:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.236 uVs 16:57:26 Integrated Voltage Measurement... 16:57:35 Voltage Offset Correction: v_off_ini = -103.951 uV, v_off_fin = -95.533 uV 16:57:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.882 uVs 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = -118.510 uV, v_off_fin = -130.711 uV 16:57:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.604 uVs 16:57:44 Integrated Voltage Measurement... 16:57:53 Voltage Offset Correction: v_off_ini = -113.983 uV, v_off_fin = -106.325 uV 16:57:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.559 uVs 16:57:53 Integrated Voltage Measurement... 16:58:02 Voltage Offset Correction: v_off_ini = -120.415 uV, v_off_fin = -129.944 uV 16:58:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.528 uVs 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = -130.380 uV, v_off_fin = -107.498 uV 16:58:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.412 uVs 16:58:16 I1Y Average and RMS of Measurements VT = -182.537 +- 1.913 uVs I1Y = -36.507 +- 0.384 uTm 16:58:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:58:21 Integrated Voltage Measurement... 16:58:30 Voltage Offset Correction: v_off_ini = -117.449 uV, v_off_fin = -119.638 uV 16:58:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.129 uVs 16:58:30 Integrated Voltage Measurement... 16:58:39 Voltage Offset Correction: v_off_ini = -110.754 uV, v_off_fin = -108.394 uV 16:58:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.139 uVs 16:58:39 Integrated Voltage Measurement... 16:58:48 Voltage Offset Correction: v_off_ini = -110.632 uV, v_off_fin = -113.896 uV 16:58:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.058 uVs 16:58:48 Integrated Voltage Measurement... 16:58:57 Voltage Offset Correction: v_off_ini = -108.719 uV, v_off_fin = -112.045 uV 16:58:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 40.298 uVs 16:58:57 Integrated Voltage Measurement... 16:59:06 Voltage Offset Correction: v_off_ini = -112.550 uV, v_off_fin = -117.387 uV 16:59:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.138 uVs 16:59:06 Integrated Voltage Measurement... 16:59:15 Voltage Offset Correction: v_off_ini = -100.303 uV, v_off_fin = -95.358 uV 16:59:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.197 uVs 16:59:17 I2X Average and RMS of Measurements VT = -47.160 +- 3.503 uVs I2X = 4.339 +- 0.322 uTm^2 16:59:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:59:22 Integrated Voltage Measurement... 16:59:31 Voltage Offset Correction: v_off_ini = -111.576 uV, v_off_fin = -116.163 uV 16:59:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -350.492 uVs 16:59:32 Integrated Voltage Measurement... 16:59:40 Voltage Offset Correction: v_off_ini = -118.643 uV, v_off_fin = -114.016 uV 16:59:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.413 uVs 16:59:41 Integrated Voltage Measurement... 16:59:49 Voltage Offset Correction: v_off_ini = -117.844 uV, v_off_fin = -116.044 uV 16:59:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.656 uVs 16:59:50 Integrated Voltage Measurement... 16:59:59 Voltage Offset Correction: v_off_ini = -106.917 uV, v_off_fin = -113.697 uV 16:59:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.867 uVs 16:59:59 Integrated Voltage Measurement... 17:00:08 Voltage Offset Correction: v_off_ini = -114.676 uV, v_off_fin = -117.449 uV 17:00:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.104 uVs 17:00:08 Integrated Voltage Measurement... 17:00:17 Voltage Offset Correction: v_off_ini = -115.069 uV, v_off_fin = -117.899 uV 17:00:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.877 uVs 17:00:19 I2Y Average and RMS of Measurements VT = -350.068 +- 2.263 uVs I2Y = -32.207 +- 0.207 uTm^2 17:00:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:00:55 Integrated Voltage Measurement... 17:01:04 Voltage Offset Correction: v_off_ini = -126.600 uV, v_off_fin = -142.858 uV 17:01:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -90.325 uVs 17:01:04 Integrated Voltage Measurement... 17:01:13 Voltage Offset Correction: v_off_ini = -137.172 uV, v_off_fin = -134.033 uV 17:01:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.124 uVs 17:01:13 Integrated Voltage Measurement... 17:01:22 Voltage Offset Correction: v_off_ini = -148.439 uV, v_off_fin = -140.059 uV 17:01:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.264 uVs 17:01:22 Integrated Voltage Measurement... 17:01:31 Voltage Offset Correction: v_off_ini = -136.287 uV, v_off_fin = -131.837 uV 17:01:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.014 uVs 17:01:31 Integrated Voltage Measurement... 17:01:40 Voltage Offset Correction: v_off_ini = -145.367 uV, v_off_fin = -138.720 uV 17:01:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.914 uVs 17:01:40 Integrated Voltage Measurement... 17:01:49 Voltage Offset Correction: v_off_ini = -135.357 uV, v_off_fin = -131.540 uV 17:01:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.388 uVs 17:01:53 I1X Average and RMS of Measurements VT = -76.838 +- 6.645 uVs I1X = 15.369 +- 1.329 uTm 17:01:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:02:00 Integrated Voltage Measurement... 17:02:09 Voltage Offset Correction: v_off_ini = -118.333 uV, v_off_fin = -119.605 uV 17:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.158 uVs 17:02:09 Integrated Voltage Measurement... 17:02:18 Voltage Offset Correction: v_off_ini = -116.790 uV, v_off_fin = -111.375 uV 17:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.055 uVs 17:02:18 Integrated Voltage Measurement... 17:02:27 Voltage Offset Correction: v_off_ini = -121.929 uV, v_off_fin = -132.184 uV 17:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.603 uVs 17:02:27 Integrated Voltage Measurement... 17:02:36 Voltage Offset Correction: v_off_ini = -125.400 uV, v_off_fin = -115.991 uV 17:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.198 uVs 17:02:36 Integrated Voltage Measurement... 17:02:45 Voltage Offset Correction: v_off_ini = -118.515 uV, v_off_fin = -130.093 uV 17:02:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.465 uVs 17:02:45 Integrated Voltage Measurement... 17:02:54 Voltage Offset Correction: v_off_ini = -113.794 uV, v_off_fin = -109.160 uV 17:02:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.317 uVs 17:02:58 I1Y Average and RMS of Measurements VT = -194.299 +- 5.086 uVs I1Y = -38.860 +- 1.017 uTm 17:03:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:03:06 Integrated Voltage Measurement... 17:03:15 Voltage Offset Correction: v_off_ini = -99.885 uV, v_off_fin = -106.455 uV 17:03:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.744 uVs 17:03:15 Integrated Voltage Measurement... 17:03:24 Voltage Offset Correction: v_off_ini = -92.738 uV, v_off_fin = -97.920 uV 17:03:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.744 uVs 17:03:24 Integrated Voltage Measurement... 17:03:33 Voltage Offset Correction: v_off_ini = -112.496 uV, v_off_fin = -124.452 uV 17:03:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.757 uVs 17:03:33 Integrated Voltage Measurement... 17:03:42 Voltage Offset Correction: v_off_ini = -111.881 uV, v_off_fin = -106.781 uV 17:03:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.542 uVs 17:03:42 Integrated Voltage Measurement... 17:03:51 Voltage Offset Correction: v_off_ini = -110.765 uV, v_off_fin = -120.101 uV 17:03:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.700 uVs 17:03:51 Integrated Voltage Measurement... 17:04:00 Voltage Offset Correction: v_off_ini = -118.260 uV, v_off_fin = -106.630 uV 17:04:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.137 uVs 17:04:02 I2X Average and RMS of Measurements VT = -80.437 +- 6.046 uVs I2X = 7.400 +- 0.556 uTm^2 17:04:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:04:10 Integrated Voltage Measurement... 17:04:19 Voltage Offset Correction: v_off_ini = -116.157 uV, v_off_fin = -117.803 uV 17:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.428 uVs 17:04:19 Integrated Voltage Measurement... 17:04:28 Voltage Offset Correction: v_off_ini = -117.821 uV, v_off_fin = -104.530 uV 17:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.823 uVs 17:04:28 Integrated Voltage Measurement... 17:04:37 Voltage Offset Correction: v_off_ini = -115.309 uV, v_off_fin = -111.621 uV 17:04:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.891 uVs 17:04:37 Integrated Voltage Measurement... 17:04:46 Voltage Offset Correction: v_off_ini = -96.988 uV, v_off_fin = -103.963 uV 17:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.253 uVs 17:04:46 Integrated Voltage Measurement... 17:04:55 Voltage Offset Correction: v_off_ini = -104.678 uV, v_off_fin = -111.815 uV 17:04:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.801 uVs 17:04:55 Integrated Voltage Measurement... 17:05:04 Voltage Offset Correction: v_off_ini = -109.133 uV, v_off_fin = -99.845 uV 17:05:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.834 uVs 17:05:06 I2Y Average and RMS of Measurements VT = -255.838 +- 7.410 uVs I2Y = -23.537 +- 0.682 uTm^2 17:05:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:05:15 Integrated Voltage Measurement... 17:05:24 Voltage Offset Correction: v_off_ini = -89.795 uV, v_off_fin = -105.381 uV 17:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.032 uVs 17:05:24 Integrated Voltage Measurement... 17:05:33 Voltage Offset Correction: v_off_ini = -89.291 uV, v_off_fin = -92.669 uV 17:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.614 uVs 17:05:33 Integrated Voltage Measurement... 17:05:42 Voltage Offset Correction: v_off_ini = -88.314 uV, v_off_fin = -101.811 uV 17:05:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.446 uVs 17:05:42 Integrated Voltage Measurement... 17:05:51 Voltage Offset Correction: v_off_ini = -94.578 uV, v_off_fin = -96.547 uV 17:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.977 uVs 17:05:51 Integrated Voltage Measurement... 17:06:00 Voltage Offset Correction: v_off_ini = -104.190 uV, v_off_fin = -103.740 uV 17:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.592 uVs 17:06:01 Integrated Voltage Measurement... 17:06:09 Voltage Offset Correction: v_off_ini = -99.162 uV, v_off_fin = -93.731 uV 17:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 80.850 uVs 17:06:14 I1X Average and RMS of Measurements VT = -75.085 +- 3.204 uVs I1X = 15.018 +- 0.641 uTm 17:06:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:06:20 Integrated Voltage Measurement... 17:06:29 Voltage Offset Correction: v_off_ini = -87.124 uV, v_off_fin = -104.468 uV 17:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.324 uVs 17:06:29 Integrated Voltage Measurement... 17:06:38 Voltage Offset Correction: v_off_ini = -104.293 uV, v_off_fin = -94.612 uV 17:06:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.806 uVs 17:06:38 Integrated Voltage Measurement... 17:06:47 Voltage Offset Correction: v_off_ini = -112.404 uV, v_off_fin = -129.836 uV 17:06:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.341 uVs 17:06:47 Integrated Voltage Measurement... 17:06:56 Voltage Offset Correction: v_off_ini = -121.655 uV, v_off_fin = -112.900 uV 17:06:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.868 uVs 17:06:56 Integrated Voltage Measurement... 17:07:05 Voltage Offset Correction: v_off_ini = -121.396 uV, v_off_fin = -128.216 uV 17:07:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.206 uVs 17:07:05 Integrated Voltage Measurement... 17:07:14 Voltage Offset Correction: v_off_ini = -106.087 uV, v_off_fin = -101.475 uV 17:07:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.968 uVs 17:07:19 I1Y Average and RMS of Measurements VT = -198.252 +- 4.776 uVs I1Y = -39.650 +- 0.955 uTm 17:07:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:07:26 Integrated Voltage Measurement... 17:07:35 Voltage Offset Correction: v_off_ini = -113.320 uV, v_off_fin = -120.855 uV 17:07:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.987 uVs 17:07:35 Integrated Voltage Measurement... 17:07:44 Voltage Offset Correction: v_off_ini = -102.861 uV, v_off_fin = -102.060 uV 17:07:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.178 uVs 17:07:44 Integrated Voltage Measurement... 17:07:53 Voltage Offset Correction: v_off_ini = -108.163 uV, v_off_fin = -116.333 uV 17:07:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.462 uVs 17:07:54 Integrated Voltage Measurement... 17:08:02 Voltage Offset Correction: v_off_ini = -109.505 uV, v_off_fin = -106.834 uV 17:08:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.857 uVs 17:08:03 Integrated Voltage Measurement... 17:08:12 Voltage Offset Correction: v_off_ini = -107.570 uV, v_off_fin = -113.716 uV 17:08:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.727 uVs 17:08:12 Integrated Voltage Measurement... 17:08:21 Voltage Offset Correction: v_off_ini = -108.680 uV, v_off_fin = -101.387 uV 17:08:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.731 uVs 17:08:23 I2X Average and RMS of Measurements VT = -71.157 +- 8.630 uVs I2X = 6.547 +- 0.794 uTm^2 17:08:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:08:31 Integrated Voltage Measurement... 17:08:40 Voltage Offset Correction: v_off_ini = -85.749 uV, v_off_fin = -96.262 uV 17:08:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.619 uVs 17:08:40 Integrated Voltage Measurement... 17:08:49 Voltage Offset Correction: v_off_ini = -88.265 uV, v_off_fin = -83.040 uV 17:08:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.439 uVs 17:08:49 Integrated Voltage Measurement... 17:08:58 Voltage Offset Correction: v_off_ini = -93.984 uV, v_off_fin = -96.167 uV 17:08:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.052 uVs 17:08:58 Integrated Voltage Measurement... 17:09:07 Voltage Offset Correction: v_off_ini = -90.696 uV, v_off_fin = -93.137 uV 17:09:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.323 uVs 17:09:07 Integrated Voltage Measurement... 17:09:16 Voltage Offset Correction: v_off_ini = -103.747 uV, v_off_fin = -100.259 uV 17:09:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.098 uVs 17:09:16 Integrated Voltage Measurement... 17:09:25 Voltage Offset Correction: v_off_ini = -95.828 uV, v_off_fin = -87.220 uV 17:09:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.845 uVs 17:09:27 I2Y Average and RMS of Measurements VT = -271.563 +- 3.846 uVs I2Y = -24.984 +- 0.354 uTm^2 17:09:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:36 Integrated Voltage Measurement... 17:09:45 Voltage Offset Correction: v_off_ini = -103.666 uV, v_off_fin = -108.297 uV 17:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.125 uVs 17:09:45 Integrated Voltage Measurement... 17:09:54 Voltage Offset Correction: v_off_ini = -102.042 uV, v_off_fin = -84.483 uV 17:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.040 uVs 17:09:54 Integrated Voltage Measurement... 17:10:03 Voltage Offset Correction: v_off_ini = -104.618 uV, v_off_fin = -97.128 uV 17:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.229 uVs 17:10:03 Integrated Voltage Measurement... 17:10:12 Voltage Offset Correction: v_off_ini = -98.360 uV, v_off_fin = -98.640 uV 17:10:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 52.489 uVs 17:10:12 Integrated Voltage Measurement... 17:10:21 Voltage Offset Correction: v_off_ini = -95.042 uV, v_off_fin = -105.067 uV 17:10:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.652 uVs 17:10:21 Integrated Voltage Measurement... 17:10:30 Voltage Offset Correction: v_off_ini = -95.632 uV, v_off_fin = -107.003 uV 17:10:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.305 uVs 17:10:35 I1X Average and RMS of Measurements VT = -71.640 +- 3.581 uVs I1X = 14.328 +- 0.716 uTm 17:10:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:41 Integrated Voltage Measurement... 17:10:50 Voltage Offset Correction: v_off_ini = -107.501 uV, v_off_fin = -113.423 uV 17:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.717 uVs 17:10:50 Integrated Voltage Measurement... 17:10:59 Voltage Offset Correction: v_off_ini = -119.429 uV, v_off_fin = -105.771 uV 17:10:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.487 uVs 17:10:59 Integrated Voltage Measurement... 17:11:08 Voltage Offset Correction: v_off_ini = -110.836 uV, v_off_fin = -129.845 uV 17:11:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.538 uVs 17:11:08 Integrated Voltage Measurement... 17:11:17 Voltage Offset Correction: v_off_ini = -103.810 uV, v_off_fin = -109.908 uV 17:11:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.707 uVs 17:11:17 Integrated Voltage Measurement... 17:11:26 Voltage Offset Correction: v_off_ini = -107.324 uV, v_off_fin = -116.501 uV 17:11:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.133 uVs 17:11:26 Integrated Voltage Measurement... 17:11:35 Voltage Offset Correction: v_off_ini = -117.557 uV, v_off_fin = -96.915 uV 17:11:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.725 uVs 17:11:40 I1Y Average and RMS of Measurements VT = -203.551 +- 0.426 uVs I1Y = -40.710 +- 0.085 uTm 17:11:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:47 Integrated Voltage Measurement... 17:11:56 Voltage Offset Correction: v_off_ini = -92.391 uV, v_off_fin = -109.732 uV 17:11:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.571 uVs 17:11:56 Integrated Voltage Measurement... 17:12:05 Voltage Offset Correction: v_off_ini = -104.689 uV, v_off_fin = -92.595 uV 17:12:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.045 uVs 17:12:05 Integrated Voltage Measurement... 17:12:14 Voltage Offset Correction: v_off_ini = -110.805 uV, v_off_fin = -103.477 uV 17:12:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.380 uVs 17:12:14 Integrated Voltage Measurement... 17:12:23 Voltage Offset Correction: v_off_ini = -88.709 uV, v_off_fin = -89.523 uV 17:12:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.039 uVs 17:12:23 Integrated Voltage Measurement... 17:12:32 Voltage Offset Correction: v_off_ini = -102.314 uV, v_off_fin = -113.517 uV 17:12:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.086 uVs 17:12:32 Integrated Voltage Measurement... 17:12:41 Voltage Offset Correction: v_off_ini = -98.000 uV, v_off_fin = -102.774 uV 17:12:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.839 uVs 17:12:44 I2X Average and RMS of Measurements VT = -74.160 +- 1.027 uVs I2X = 6.823 +- 0.095 uTm^2 17:12:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:52 Integrated Voltage Measurement... 17:13:01 Voltage Offset Correction: v_off_ini = -88.177 uV, v_off_fin = -96.566 uV 17:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.452 uVs 17:13:01 Integrated Voltage Measurement... 17:13:10 Voltage Offset Correction: v_off_ini = -101.956 uV, v_off_fin = -95.248 uV 17:13:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.887 uVs 17:13:10 Integrated Voltage Measurement... 17:13:19 Voltage Offset Correction: v_off_ini = -100.664 uV, v_off_fin = -103.546 uV 17:13:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.793 uVs 17:13:19 Integrated Voltage Measurement... 17:13:28 Voltage Offset Correction: v_off_ini = -97.630 uV, v_off_fin = -102.112 uV 17:13:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.938 uVs 17:13:28 Integrated Voltage Measurement... 17:13:37 Voltage Offset Correction: v_off_ini = -108.053 uV, v_off_fin = -102.782 uV 17:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.005 uVs 17:13:37 Integrated Voltage Measurement... 17:13:46 Voltage Offset Correction: v_off_ini = -113.303 uV, v_off_fin = -120.102 uV 17:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.498 uVs 17:13:48 I2Y Average and RMS of Measurements VT = -268.596 +- 2.733 uVs I2Y = -24.711 +- 0.251 uTm^2 17:13:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:13:57 Integrated Voltage Measurement... 17:14:06 Voltage Offset Correction: v_off_ini = -100.774 uV, v_off_fin = -101.837 uV 17:14:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.253 uVs 17:14:06 Integrated Voltage Measurement... 17:14:15 Voltage Offset Correction: v_off_ini = -102.819 uV, v_off_fin = -98.233 uV 17:14:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.890 uVs 17:14:15 Integrated Voltage Measurement... 17:14:24 Voltage Offset Correction: v_off_ini = -104.567 uV, v_off_fin = -106.466 uV 17:14:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.324 uVs 17:14:24 Integrated Voltage Measurement... 17:14:33 Voltage Offset Correction: v_off_ini = -104.725 uV, v_off_fin = -103.205 uV 17:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.254 uVs 17:14:33 Integrated Voltage Measurement... 17:14:42 Voltage Offset Correction: v_off_ini = -112.588 uV, v_off_fin = -126.104 uV 17:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.468 uVs 17:14:42 Integrated Voltage Measurement... 17:14:51 Voltage Offset Correction: v_off_ini = -113.872 uV, v_off_fin = -104.778 uV 17:14:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.022 uVs 17:14:55 I1X Average and RMS of Measurements VT = -80.868 +- 5.627 uVs I1X = 16.174 +- 1.126 uTm 17:14:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:15:02 Integrated Voltage Measurement... 17:15:11 Voltage Offset Correction: v_off_ini = -112.005 uV, v_off_fin = -119.164 uV 17:15:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.907 uVs 17:15:11 Integrated Voltage Measurement... 17:15:20 Voltage Offset Correction: v_off_ini = -113.943 uV, v_off_fin = -99.064 uV 17:15:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.437 uVs 17:15:20 Integrated Voltage Measurement... 17:15:29 Voltage Offset Correction: v_off_ini = -115.975 uV, v_off_fin = -127.833 uV 17:15:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.516 uVs 17:15:29 Integrated Voltage Measurement... 17:15:38 Voltage Offset Correction: v_off_ini = -98.218 uV, v_off_fin = -106.211 uV 17:15:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.031 uVs 17:15:38 Integrated Voltage Measurement... 17:15:47 Voltage Offset Correction: v_off_ini = -115.963 uV, v_off_fin = -120.621 uV 17:15:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.453 uVs 17:15:47 Integrated Voltage Measurement... 17:15:56 Voltage Offset Correction: v_off_ini = -119.117 uV, v_off_fin = -111.806 uV 17:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.434 uVs 17:16:00 I1Y Average and RMS of Measurements VT = -205.130 +- 0.275 uVs I1Y = -41.026 +- 0.055 uTm 17:16:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:16:08 Integrated Voltage Measurement... 17:16:17 Voltage Offset Correction: v_off_ini = -124.813 uV, v_off_fin = -124.364 uV 17:16:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.076 uVs 17:16:17 Integrated Voltage Measurement... 17:16:26 Voltage Offset Correction: v_off_ini = -122.455 uV, v_off_fin = -116.896 uV 17:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.604 uVs 17:16:26 Integrated Voltage Measurement... 17:16:35 Voltage Offset Correction: v_off_ini = -127.296 uV, v_off_fin = -135.758 uV 17:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.184 uVs 17:16:35 Integrated Voltage Measurement... 17:16:44 Voltage Offset Correction: v_off_ini = -123.562 uV, v_off_fin = -105.137 uV 17:16:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.273 uVs 17:16:44 Integrated Voltage Measurement... 17:16:53 Voltage Offset Correction: v_off_ini = -118.081 uV, v_off_fin = -141.321 uV 17:16:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.341 uVs 17:16:53 Integrated Voltage Measurement... 17:17:02 Voltage Offset Correction: v_off_ini = -112.378 uV, v_off_fin = -102.959 uV 17:17:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.854 uVs 17:17:05 I2X Average and RMS of Measurements VT = -72.722 +- 9.189 uVs I2X = 6.691 +- 0.846 uTm^2 17:17:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:17:12 Integrated Voltage Measurement... 17:17:21 Voltage Offset Correction: v_off_ini = -96.657 uV, v_off_fin = -100.604 uV 17:17:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.088 uVs 17:17:21 Integrated Voltage Measurement... 17:17:30 Voltage Offset Correction: v_off_ini = -101.339 uV, v_off_fin = -101.203 uV 17:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.583 uVs 17:17:31 Integrated Voltage Measurement... 17:17:39 Voltage Offset Correction: v_off_ini = -101.478 uV, v_off_fin = -112.505 uV 17:17:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.651 uVs 17:17:40 Integrated Voltage Measurement... 17:17:49 Voltage Offset Correction: v_off_ini = -101.312 uV, v_off_fin = -104.512 uV 17:17:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.818 uVs 17:17:49 Integrated Voltage Measurement... 17:17:58 Voltage Offset Correction: v_off_ini = -101.458 uV, v_off_fin = -104.184 uV 17:17:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.270 uVs 17:17:58 Integrated Voltage Measurement... 17:18:07 Voltage Offset Correction: v_off_ini = -107.980 uV, v_off_fin = -101.954 uV 17:18:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.123 uVs 17:18:09 I2Y Average and RMS of Measurements VT = -274.589 +- 9.004 uVs I2Y = -25.262 +- 0.828 uTm^2 17:18:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:18:18 Integrated Voltage Measurement... 17:18:27 Voltage Offset Correction: v_off_ini = -89.060 uV, v_off_fin = -96.229 uV 17:18:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.644 uVs 17:18:27 Integrated Voltage Measurement... 17:18:36 Voltage Offset Correction: v_off_ini = -84.167 uV, v_off_fin = -85.150 uV 17:18:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.699 uVs 17:18:36 Integrated Voltage Measurement... 17:18:45 Voltage Offset Correction: v_off_ini = -92.273 uV, v_off_fin = -94.371 uV 17:18:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.549 uVs 17:18:45 Integrated Voltage Measurement... 17:18:54 Voltage Offset Correction: v_off_ini = -86.937 uV, v_off_fin = -84.135 uV 17:18:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.710 uVs 17:18:54 Integrated Voltage Measurement... 17:19:03 Voltage Offset Correction: v_off_ini = -88.742 uV, v_off_fin = -95.325 uV 17:19:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.764 uVs 17:19:03 Integrated Voltage Measurement... 17:19:12 Voltage Offset Correction: v_off_ini = -95.757 uV, v_off_fin = -92.780 uV 17:19:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.612 uVs 17:19:16 I1X Average and RMS of Measurements VT = -78.330 +- 6.437 uVs I1X = 15.666 +- 1.287 uTm 17:19:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:19:23 Integrated Voltage Measurement... 17:19:32 Voltage Offset Correction: v_off_ini = -102.632 uV, v_off_fin = -102.286 uV 17:19:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.276 uVs 17:19:32 Integrated Voltage Measurement... 17:19:41 Voltage Offset Correction: v_off_ini = -94.421 uV, v_off_fin = -91.135 uV 17:19:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.445 uVs 17:19:41 Integrated Voltage Measurement... 17:19:50 Voltage Offset Correction: v_off_ini = -91.076 uV, v_off_fin = -99.194 uV 17:19:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.532 uVs 17:19:50 Integrated Voltage Measurement... 17:19:59 Voltage Offset Correction: v_off_ini = -80.170 uV, v_off_fin = -80.217 uV 17:19:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.971 uVs 17:19:59 Integrated Voltage Measurement... 17:20:08 Voltage Offset Correction: v_off_ini = -80.921 uV, v_off_fin = -101.376 uV 17:20:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.623 uVs 17:20:08 Integrated Voltage Measurement... 17:20:17 Voltage Offset Correction: v_off_ini = -89.427 uV, v_off_fin = -80.553 uV 17:20:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.391 uVs 17:20:21 I1Y Average and RMS of Measurements VT = -197.040 +- 2.926 uVs I1Y = -39.408 +- 0.585 uTm 17:20:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:20:29 Integrated Voltage Measurement... 17:20:38 Voltage Offset Correction: v_off_ini = -109.144 uV, v_off_fin = -106.250 uV 17:20:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.624 uVs 17:20:38 Integrated Voltage Measurement... 17:20:47 Voltage Offset Correction: v_off_ini = -95.427 uV, v_off_fin = -88.329 uV 17:20:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.180 uVs 17:20:47 Integrated Voltage Measurement... 17:20:56 Voltage Offset Correction: v_off_ini = -96.541 uV, v_off_fin = -105.689 uV 17:20:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.984 uVs 17:20:56 Integrated Voltage Measurement... 17:21:05 Voltage Offset Correction: v_off_ini = -117.315 uV, v_off_fin = -93.492 uV 17:21:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.191 uVs 17:21:05 Integrated Voltage Measurement... 17:21:14 Voltage Offset Correction: v_off_ini = -101.726 uV, v_off_fin = -103.448 uV 17:21:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.936 uVs 17:21:14 Integrated Voltage Measurement... 17:21:23 Voltage Offset Correction: v_off_ini = -86.399 uV, v_off_fin = -93.616 uV 17:21:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.458 uVs 17:21:25 I2X Average and RMS of Measurements VT = -78.896 +- 5.594 uVs I2X = 7.258 +- 0.515 uTm^2 17:21:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:21:33 Integrated Voltage Measurement... 17:21:42 Voltage Offset Correction: v_off_ini = -98.286 uV, v_off_fin = -89.523 uV 17:21:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.914 uVs 17:21:42 Integrated Voltage Measurement... 17:21:51 Voltage Offset Correction: v_off_ini = -92.963 uV, v_off_fin = -86.191 uV 17:21:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.331 uVs 17:21:51 Integrated Voltage Measurement... 17:22:00 Voltage Offset Correction: v_off_ini = -91.403 uV, v_off_fin = -100.222 uV 17:22:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.224 uVs 17:22:00 Integrated Voltage Measurement... 17:22:09 Voltage Offset Correction: v_off_ini = -91.535 uV, v_off_fin = -83.449 uV 17:22:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.614 uVs 17:22:09 Integrated Voltage Measurement... 17:22:18 Voltage Offset Correction: v_off_ini = -91.707 uV, v_off_fin = -103.064 uV 17:22:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.638 uVs 17:22:18 Integrated Voltage Measurement... 17:22:27 Voltage Offset Correction: v_off_ini = -86.541 uV, v_off_fin = -90.021 uV 17:22:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.499 uVs 17:22:30 I2Y Average and RMS of Measurements VT = -271.870 +- 3.129 uVs I2Y = -25.012 +- 0.288 uTm^2 17:22:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:22:42 Integrated Voltage Measurement... 17:22:51 Voltage Offset Correction: v_off_ini = -72.017 uV, v_off_fin = -95.517 uV 17:22:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.052 uVs 17:22:51 Integrated Voltage Measurement... 17:23:00 Voltage Offset Correction: v_off_ini = -104.686 uV, v_off_fin = -80.302 uV 17:23:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.226 uVs 17:23:00 Integrated Voltage Measurement... 17:23:09 Voltage Offset Correction: v_off_ini = -80.732 uV, v_off_fin = -82.545 uV 17:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.437 uVs 17:23:09 Integrated Voltage Measurement... 17:23:18 Voltage Offset Correction: v_off_ini = -83.888 uV, v_off_fin = -85.722 uV 17:23:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.432 uVs 17:23:18 Integrated Voltage Measurement... 17:23:27 Voltage Offset Correction: v_off_ini = -91.272 uV, v_off_fin = -95.704 uV 17:23:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.834 uVs 17:23:27 Integrated Voltage Measurement... 17:23:36 Voltage Offset Correction: v_off_ini = -83.278 uV, v_off_fin = -93.893 uV 17:23:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.725 uVs 17:23:40 I1X Average and RMS of Measurements VT = -66.284 +- 6.269 uVs I1X = 13.257 +- 1.253 uTm 17:23:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:23:47 Integrated Voltage Measurement... 17:23:56 Voltage Offset Correction: v_off_ini = -95.988 uV, v_off_fin = -91.319 uV 17:23:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.697 uVs 17:23:56 Integrated Voltage Measurement... 17:24:05 Voltage Offset Correction: v_off_ini = -80.398 uV, v_off_fin = -78.578 uV 17:24:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.820 uVs 17:24:05 Integrated Voltage Measurement... 17:24:14 Voltage Offset Correction: v_off_ini = -80.144 uV, v_off_fin = -96.491 uV 17:24:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.549 uVs 17:24:14 Integrated Voltage Measurement... 17:24:23 Voltage Offset Correction: v_off_ini = -87.200 uV, v_off_fin = -63.593 uV 17:24:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.010 uVs 17:24:23 Integrated Voltage Measurement... 17:24:32 Voltage Offset Correction: v_off_ini = -83.208 uV, v_off_fin = -96.207 uV 17:24:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -200.499 uVs 17:24:32 Integrated Voltage Measurement... 17:24:41 Voltage Offset Correction: v_off_ini = -94.356 uV, v_off_fin = -79.363 uV 17:24:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.816 uVs 17:24:45 I1Y Average and RMS of Measurements VT = -200.732 +- 3.266 uVs I1Y = -40.147 +- 0.653 uTm 17:24:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:24:50 Integrated Voltage Measurement... 17:24:59 Voltage Offset Correction: v_off_ini = -107.961 uV, v_off_fin = -106.748 uV 17:24:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.790 uVs 17:24:59 Integrated Voltage Measurement... 17:25:08 Voltage Offset Correction: v_off_ini = -86.175 uV, v_off_fin = -75.051 uV 17:25:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.535 uVs 17:25:08 Integrated Voltage Measurement... 17:25:17 Voltage Offset Correction: v_off_ini = -88.626 uV, v_off_fin = -97.877 uV 17:25:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.729 uVs 17:25:17 Integrated Voltage Measurement... 17:25:26 Voltage Offset Correction: v_off_ini = -96.920 uV, v_off_fin = -89.402 uV 17:25:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.636 uVs 17:25:26 Integrated Voltage Measurement... 17:25:35 Voltage Offset Correction: v_off_ini = -105.461 uV, v_off_fin = -117.102 uV 17:25:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.068 uVs 17:25:35 Integrated Voltage Measurement... 17:25:44 Voltage Offset Correction: v_off_ini = -101.757 uV, v_off_fin = -92.640 uV 17:25:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.749 uVs 17:25:47 I2X Average and RMS of Measurements VT = -61.918 +- 2.062 uVs I2X = 5.697 +- 0.190 uTm^2 17:25:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:25:52 Integrated Voltage Measurement... 17:26:01 Voltage Offset Correction: v_off_ini = -97.179 uV, v_off_fin = -101.703 uV 17:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.967 uVs 17:26:01 Integrated Voltage Measurement... 17:26:10 Voltage Offset Correction: v_off_ini = -102.802 uV, v_off_fin = -89.305 uV 17:26:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.141 uVs 17:26:10 Integrated Voltage Measurement... 17:26:19 Voltage Offset Correction: v_off_ini = -90.016 uV, v_off_fin = -94.121 uV 17:26:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.004 uVs 17:26:19 Integrated Voltage Measurement... 17:26:28 Voltage Offset Correction: v_off_ini = -102.030 uV, v_off_fin = -92.383 uV 17:26:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 252.973 uVs 17:26:28 Integrated Voltage Measurement... 17:26:37 Voltage Offset Correction: v_off_ini = -98.162 uV, v_off_fin = -94.257 uV 17:26:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.436 uVs 17:26:37 Integrated Voltage Measurement... 17:26:46 Voltage Offset Correction: v_off_ini = -98.713 uV, v_off_fin = -103.514 uV 17:26:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.465 uVs 17:26:49 I2Y Average and RMS of Measurements VT = -265.164 +- 4.841 uVs I2Y = -24.396 +- 0.445 uTm^2 17:26:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:26:57 Integrated Voltage Measurement... 17:27:06 Voltage Offset Correction: v_off_ini = -116.421 uV, v_off_fin = -126.298 uV 17:27:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -73.244 uVs 17:27:06 Integrated Voltage Measurement... 17:27:15 Voltage Offset Correction: v_off_ini = -112.601 uV, v_off_fin = -113.819 uV 17:27:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.078 uVs 17:27:15 Integrated Voltage Measurement... 17:27:24 Voltage Offset Correction: v_off_ini = -128.115 uV, v_off_fin = -118.625 uV 17:27:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.824 uVs 17:27:24 Integrated Voltage Measurement... 17:27:33 Voltage Offset Correction: v_off_ini = -108.314 uV, v_off_fin = -100.988 uV 17:27:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.690 uVs 17:27:33 Integrated Voltage Measurement... 17:27:42 Voltage Offset Correction: v_off_ini = -124.679 uV, v_off_fin = -117.968 uV 17:27:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.549 uVs 17:27:42 Integrated Voltage Measurement... 17:27:51 Voltage Offset Correction: v_off_ini = -94.619 uV, v_off_fin = -103.586 uV 17:27:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.304 uVs 17:27:55 I1X Average and RMS of Measurements VT = -59.781 +- 4.641 uVs I1X = 11.957 +- 0.929 uTm 17:27:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:28:02 Integrated Voltage Measurement... 17:28:11 Voltage Offset Correction: v_off_ini = -111.846 uV, v_off_fin = -115.639 uV 17:28:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.496 uVs 17:28:11 Integrated Voltage Measurement... 17:28:20 Voltage Offset Correction: v_off_ini = -109.123 uV, v_off_fin = -113.472 uV 17:28:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.345 uVs 17:28:20 Integrated Voltage Measurement... 17:28:29 Voltage Offset Correction: v_off_ini = -117.393 uV, v_off_fin = -126.871 uV 17:28:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.869 uVs 17:28:29 Integrated Voltage Measurement... 17:28:38 Voltage Offset Correction: v_off_ini = -111.717 uV, v_off_fin = -109.725 uV 17:28:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.656 uVs 17:28:38 Integrated Voltage Measurement... 17:28:47 Voltage Offset Correction: v_off_ini = -115.077 uV, v_off_fin = -125.475 uV 17:28:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.747 uVs 17:28:47 Integrated Voltage Measurement... 17:28:56 Voltage Offset Correction: v_off_ini = -111.208 uV, v_off_fin = -92.465 uV 17:28:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.743 uVs 17:29:00 I1Y Average and RMS of Measurements VT = -199.476 +- 3.697 uVs I1Y = -39.895 +- 0.739 uTm 17:29:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:29:05 Integrated Voltage Measurement... 17:29:14 Voltage Offset Correction: v_off_ini = -104.848 uV, v_off_fin = -120.711 uV 17:29:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.441 uVs 17:29:14 Integrated Voltage Measurement... 17:29:23 Voltage Offset Correction: v_off_ini = -114.413 uV, v_off_fin = -103.872 uV 17:29:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.543 uVs 17:29:23 Integrated Voltage Measurement... 17:29:32 Voltage Offset Correction: v_off_ini = -121.468 uV, v_off_fin = -131.324 uV 17:29:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.703 uVs 17:29:32 Integrated Voltage Measurement... 17:29:41 Voltage Offset Correction: v_off_ini = -121.612 uV, v_off_fin = -103.147 uV 17:29:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.327 uVs 17:29:41 Integrated Voltage Measurement... 17:29:50 Voltage Offset Correction: v_off_ini = -110.922 uV, v_off_fin = -135.235 uV 17:29:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.028 uVs 17:29:50 Integrated Voltage Measurement... 17:29:59 Voltage Offset Correction: v_off_ini = -126.145 uV, v_off_fin = -124.884 uV 17:29:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.901 uVs 17:30:02 I2X Average and RMS of Measurements VT = -70.491 +- 1.061 uVs I2X = 6.485 +- 0.098 uTm^2 17:30:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:30:07 Integrated Voltage Measurement... 17:30:16 Voltage Offset Correction: v_off_ini = -123.931 uV, v_off_fin = -126.226 uV 17:30:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.711 uVs 17:30:16 Integrated Voltage Measurement... 17:30:25 Voltage Offset Correction: v_off_ini = -123.319 uV, v_off_fin = -125.212 uV 17:30:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.578 uVs 17:30:25 Integrated Voltage Measurement... 17:30:34 Voltage Offset Correction: v_off_ini = -113.746 uV, v_off_fin = -143.584 uV 17:30:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.612 uVs 17:30:34 Integrated Voltage Measurement... 17:30:43 Voltage Offset Correction: v_off_ini = -140.321 uV, v_off_fin = -129.341 uV 17:30:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.661 uVs 17:30:43 Integrated Voltage Measurement... 17:30:52 Voltage Offset Correction: v_off_ini = -130.602 uV, v_off_fin = -135.377 uV 17:30:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.095 uVs 17:30:52 Integrated Voltage Measurement... 17:31:01 Voltage Offset Correction: v_off_ini = -135.417 uV, v_off_fin = -132.109 uV 17:31:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 280.957 uVs 17:31:04 I2Y Average and RMS of Measurements VT = -274.936 +- 5.060 uVs I2Y = -25.295 +- 0.466 uTm^2 17:31:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:31:12 Integrated Voltage Measurement... 17:31:21 Voltage Offset Correction: v_off_ini = -141.891 uV, v_off_fin = -144.195 uV 17:31:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.607 uVs 17:31:21 Integrated Voltage Measurement... 17:31:30 Voltage Offset Correction: v_off_ini = -147.942 uV, v_off_fin = -126.332 uV 17:31:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.728 uVs 17:31:30 Integrated Voltage Measurement... 17:31:39 Voltage Offset Correction: v_off_ini = -127.020 uV, v_off_fin = -129.475 uV 17:31:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.019 uVs 17:31:39 Integrated Voltage Measurement... 17:31:48 Voltage Offset Correction: v_off_ini = -128.921 uV, v_off_fin = -129.039 uV 17:31:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.364 uVs 17:31:48 Integrated Voltage Measurement... 17:31:57 Voltage Offset Correction: v_off_ini = -135.760 uV, v_off_fin = -131.381 uV 17:31:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.449 uVs 17:31:57 Integrated Voltage Measurement... 17:32:06 Voltage Offset Correction: v_off_ini = -129.732 uV, v_off_fin = -124.950 uV 17:32:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.557 uVs 17:32:10 I1X Average and RMS of Measurements VT = -69.954 +- 5.410 uVs I1X = 13.991 +- 1.082 uTm 17:32:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:32:17 Integrated Voltage Measurement... 17:32:26 Voltage Offset Correction: v_off_ini = -126.943 uV, v_off_fin = -135.495 uV 17:32:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.009 uVs 17:32:26 Integrated Voltage Measurement... 17:32:35 Voltage Offset Correction: v_off_ini = -127.216 uV, v_off_fin = -125.246 uV 17:32:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.542 uVs 17:32:35 Integrated Voltage Measurement... 17:32:44 Voltage Offset Correction: v_off_ini = -125.782 uV, v_off_fin = -134.198 uV 17:32:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.117 uVs 17:32:44 Integrated Voltage Measurement... 17:32:53 Voltage Offset Correction: v_off_ini = -143.317 uV, v_off_fin = -126.469 uV 17:32:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.128 uVs 17:32:53 Integrated Voltage Measurement... 17:33:02 Voltage Offset Correction: v_off_ini = -133.198 uV, v_off_fin = -140.885 uV 17:33:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.513 uVs 17:33:02 Integrated Voltage Measurement... 17:33:11 Voltage Offset Correction: v_off_ini = -139.818 uV, v_off_fin = -122.376 uV 17:33:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.629 uVs 17:33:15 I1Y Average and RMS of Measurements VT = -197.156 +- 2.744 uVs I1Y = -39.431 +- 0.549 uTm 17:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:20 Integrated Voltage Measurement... 17:33:29 Voltage Offset Correction: v_off_ini = -126.738 uV, v_off_fin = -120.266 uV 17:33:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.870 uVs 17:33:29 Integrated Voltage Measurement... 17:33:38 Voltage Offset Correction: v_off_ini = -131.972 uV, v_off_fin = -122.348 uV 17:33:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.739 uVs 17:33:38 Integrated Voltage Measurement... 17:33:47 Voltage Offset Correction: v_off_ini = -129.486 uV, v_off_fin = -129.621 uV 17:33:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.881 uVs 17:33:47 Integrated Voltage Measurement... 17:33:56 Voltage Offset Correction: v_off_ini = -126.620 uV, v_off_fin = -117.229 uV 17:33:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.649 uVs 17:33:57 Integrated Voltage Measurement... 17:34:06 Voltage Offset Correction: v_off_ini = -123.029 uV, v_off_fin = -119.763 uV 17:34:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.391 uVs 17:34:06 Integrated Voltage Measurement... 17:34:15 Voltage Offset Correction: v_off_ini = -115.350 uV, v_off_fin = -97.290 uV 17:34:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.527 uVs 17:34:17 I2X Average and RMS of Measurements VT = -79.843 +- 0.488 uVs I2X = 7.346 +- 0.045 uTm^2 17:34:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:22 Integrated Voltage Measurement... 17:34:31 Voltage Offset Correction: v_off_ini = -114.922 uV, v_off_fin = -111.164 uV 17:34:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.032 uVs 17:34:31 Integrated Voltage Measurement... 17:34:40 Voltage Offset Correction: v_off_ini = -107.762 uV, v_off_fin = -105.250 uV 17:34:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.729 uVs 17:34:40 Integrated Voltage Measurement... 17:34:49 Voltage Offset Correction: v_off_ini = -108.226 uV, v_off_fin = -113.698 uV 17:34:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.851 uVs 17:34:49 Integrated Voltage Measurement... 17:34:58 Voltage Offset Correction: v_off_ini = -119.603 uV, v_off_fin = -117.414 uV 17:34:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.652 uVs 17:34:58 Integrated Voltage Measurement... 17:35:07 Voltage Offset Correction: v_off_ini = -125.168 uV, v_off_fin = -139.325 uV 17:35:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.609 uVs 17:35:07 Integrated Voltage Measurement... 17:35:16 Voltage Offset Correction: v_off_ini = -133.710 uV, v_off_fin = -135.267 uV 17:35:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.960 uVs 17:35:19 I2Y Average and RMS of Measurements VT = -265.472 +- 3.672 uVs I2Y = -24.423 +- 0.338 uTm^2 17:35:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:35:27 Integrated Voltage Measurement... 17:35:36 Voltage Offset Correction: v_off_ini = -135.739 uV, v_off_fin = -136.391 uV 17:35:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.502 uVs 17:35:36 Integrated Voltage Measurement... 17:35:45 Voltage Offset Correction: v_off_ini = -117.454 uV, v_off_fin = -121.099 uV 17:35:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.391 uVs 17:35:45 Integrated Voltage Measurement... 17:35:54 Voltage Offset Correction: v_off_ini = -129.452 uV, v_off_fin = -124.926 uV 17:35:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.062 uVs 17:35:54 Integrated Voltage Measurement... 17:36:03 Voltage Offset Correction: v_off_ini = -131.064 uV, v_off_fin = -132.724 uV 17:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.705 uVs 17:36:03 Integrated Voltage Measurement... 17:36:12 Voltage Offset Correction: v_off_ini = -122.600 uV, v_off_fin = -130.787 uV 17:36:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.401 uVs 17:36:12 Integrated Voltage Measurement... 17:36:21 Voltage Offset Correction: v_off_ini = -129.437 uV, v_off_fin = -130.767 uV 17:36:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.617 uVs 17:36:25 I1X Average and RMS of Measurements VT = -76.946 +- 11.083 uVs I1X = 15.389 +- 2.216 uTm 17:36:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:36:32 Integrated Voltage Measurement... 17:36:41 Voltage Offset Correction: v_off_ini = -135.576 uV, v_off_fin = -149.212 uV 17:36:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.470 uVs 17:36:41 Integrated Voltage Measurement... 17:36:50 Voltage Offset Correction: v_off_ini = -133.972 uV, v_off_fin = -121.011 uV 17:36:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.165 uVs 17:36:50 Integrated Voltage Measurement... 17:36:59 Voltage Offset Correction: v_off_ini = -134.906 uV, v_off_fin = -131.605 uV 17:36:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.202 uVs 17:36:59 Integrated Voltage Measurement... 17:37:08 Voltage Offset Correction: v_off_ini = -131.991 uV, v_off_fin = -133.482 uV 17:37:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.531 uVs 17:37:08 Integrated Voltage Measurement... 17:37:17 Voltage Offset Correction: v_off_ini = -132.440 uV, v_off_fin = -146.163 uV 17:37:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.479 uVs 17:37:17 Integrated Voltage Measurement... 17:37:26 Voltage Offset Correction: v_off_ini = -127.645 uV, v_off_fin = -128.866 uV 17:37:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.430 uVs 17:37:30 I1Y Average and RMS of Measurements VT = -199.879 +- 3.607 uVs I1Y = -39.974 +- 0.720 uTm 17:37:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:37:35 Integrated Voltage Measurement... 17:37:44 Voltage Offset Correction: v_off_ini = -132.212 uV, v_off_fin = -153.010 uV 17:37:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.728 uVs 17:37:44 Integrated Voltage Measurement... 17:37:53 Voltage Offset Correction: v_off_ini = -149.804 uV, v_off_fin = -136.010 uV 17:37:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.430 uVs 17:37:53 Integrated Voltage Measurement... 17:38:02 Voltage Offset Correction: v_off_ini = -140.575 uV, v_off_fin = -149.349 uV 17:38:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.536 uVs 17:38:02 Integrated Voltage Measurement... 17:38:11 Voltage Offset Correction: v_off_ini = -152.970 uV, v_off_fin = -140.632 uV 17:38:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 69.109 uVs 17:38:12 Integrated Voltage Measurement... 17:38:20 Voltage Offset Correction: v_off_ini = -147.174 uV, v_off_fin = -156.649 uV 17:38:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.999 uVs 17:38:21 Integrated Voltage Measurement... 17:38:30 Voltage Offset Correction: v_off_ini = -132.420 uV, v_off_fin = -126.231 uV 17:38:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.140 uVs 17:38:32 I2X Average and RMS of Measurements VT = -72.157 +- 8.782 uVs I2X = 6.639 +- 0.808 uTm^2 17:38:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:38:37 Integrated Voltage Measurement... 17:38:46 Voltage Offset Correction: v_off_ini = -141.473 uV, v_off_fin = -149.695 uV 17:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.073 uVs 17:38:46 Integrated Voltage Measurement... 17:38:55 Voltage Offset Correction: v_off_ini = -140.940 uV, v_off_fin = -135.236 uV 17:38:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.035 uVs 17:38:55 Integrated Voltage Measurement... 17:39:04 Voltage Offset Correction: v_off_ini = -133.224 uV, v_off_fin = -141.409 uV 17:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.425 uVs 17:39:04 Integrated Voltage Measurement... 17:39:13 Voltage Offset Correction: v_off_ini = -134.819 uV, v_off_fin = -142.602 uV 17:39:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.911 uVs 17:39:13 Integrated Voltage Measurement... 17:39:22 Voltage Offset Correction: v_off_ini = -140.248 uV, v_off_fin = -148.308 uV 17:39:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -274.305 uVs 17:39:22 Integrated Voltage Measurement... 17:39:31 Voltage Offset Correction: v_off_ini = -153.854 uV, v_off_fin = -152.442 uV 17:39:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.050 uVs 17:39:34 I2Y Average and RMS of Measurements VT = -268.800 +- 3.689 uVs I2Y = -24.730 +- 0.340 uTm^2 17:39:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:39:42 Integrated Voltage Measurement... 17:39:51 Voltage Offset Correction: v_off_ini = -142.707 uV, v_off_fin = -157.187 uV 17:39:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.729 uVs 17:39:51 Integrated Voltage Measurement... 17:40:00 Voltage Offset Correction: v_off_ini = -144.268 uV, v_off_fin = -144.893 uV 17:40:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.592 uVs 17:40:00 Integrated Voltage Measurement... 17:40:09 Voltage Offset Correction: v_off_ini = -160.166 uV, v_off_fin = -160.082 uV 17:40:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.794 uVs 17:40:09 Integrated Voltage Measurement... 17:40:18 Voltage Offset Correction: v_off_ini = -151.890 uV, v_off_fin = -148.018 uV 17:40:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.508 uVs 17:40:18 Integrated Voltage Measurement... 17:40:27 Voltage Offset Correction: v_off_ini = -162.942 uV, v_off_fin = -152.281 uV 17:40:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.692 uVs 17:40:27 Integrated Voltage Measurement... 17:40:36 Voltage Offset Correction: v_off_ini = -148.779 uV, v_off_fin = -150.590 uV 17:40:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.935 uVs 17:40:40 I1X Average and RMS of Measurements VT = -69.042 +- 3.893 uVs I1X = 13.808 +- 0.779 uTm 17:40:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:40:47 Integrated Voltage Measurement... 17:40:56 Voltage Offset Correction: v_off_ini = -147.201 uV, v_off_fin = -173.527 uV 17:40:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.818 uVs 17:40:56 Integrated Voltage Measurement... 17:41:05 Voltage Offset Correction: v_off_ini = -168.509 uV, v_off_fin = -161.491 uV 17:41:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.596 uVs 17:41:05 Integrated Voltage Measurement... 17:41:14 Voltage Offset Correction: v_off_ini = -161.820 uV, v_off_fin = -171.255 uV 17:41:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.192 uVs 17:41:14 Integrated Voltage Measurement... 17:41:23 Voltage Offset Correction: v_off_ini = -168.475 uV, v_off_fin = -151.560 uV 17:41:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.906 uVs 17:41:23 Integrated Voltage Measurement... 17:41:32 Voltage Offset Correction: v_off_ini = -160.333 uV, v_off_fin = -172.256 uV 17:41:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.008 uVs 17:41:32 Integrated Voltage Measurement... 17:41:41 Voltage Offset Correction: v_off_ini = -169.048 uV, v_off_fin = -161.571 uV 17:41:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.843 uVs 17:41:45 I1Y Average and RMS of Measurements VT = -193.394 +- 3.185 uVs I1Y = -38.675 +- 0.637 uTm 17:41:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:41:50 Integrated Voltage Measurement... 17:41:59 Voltage Offset Correction: v_off_ini = -183.240 uV, v_off_fin = -181.663 uV 17:41:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.622 uVs 17:41:59 Integrated Voltage Measurement... 17:42:08 Voltage Offset Correction: v_off_ini = -167.226 uV, v_off_fin = -156.734 uV 17:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.094 uVs 17:42:08 Integrated Voltage Measurement... 17:42:17 Voltage Offset Correction: v_off_ini = -172.536 uV, v_off_fin = -169.765 uV 17:42:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.035 uVs 17:42:18 Integrated Voltage Measurement... 17:42:26 Voltage Offset Correction: v_off_ini = -157.811 uV, v_off_fin = -158.179 uV 17:42:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.564 uVs 17:42:27 Integrated Voltage Measurement... 17:42:36 Voltage Offset Correction: v_off_ini = -169.162 uV, v_off_fin = -173.358 uV 17:42:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.566 uVs 17:42:36 Integrated Voltage Measurement... 17:42:45 Voltage Offset Correction: v_off_ini = -170.411 uV, v_off_fin = -159.139 uV 17:42:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.366 uVs 17:42:47 I2X Average and RMS of Measurements VT = -61.708 +- 5.070 uVs I2X = 5.677 +- 0.466 uTm^2 17:42:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:42:52 Integrated Voltage Measurement... 17:43:01 Voltage Offset Correction: v_off_ini = -153.212 uV, v_off_fin = -174.561 uV 17:43:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.761 uVs 17:43:01 Integrated Voltage Measurement... 17:43:10 Voltage Offset Correction: v_off_ini = -173.025 uV, v_off_fin = -167.131 uV 17:43:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.623 uVs 17:43:10 Integrated Voltage Measurement... 17:43:19 Voltage Offset Correction: v_off_ini = -174.218 uV, v_off_fin = -179.988 uV 17:43:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.050 uVs 17:43:19 Integrated Voltage Measurement... 17:43:28 Voltage Offset Correction: v_off_ini = -179.826 uV, v_off_fin = -165.342 uV 17:43:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.336 uVs 17:43:28 Integrated Voltage Measurement... 17:43:37 Voltage Offset Correction: v_off_ini = -170.891 uV, v_off_fin = -177.729 uV 17:43:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.215 uVs 17:43:37 Integrated Voltage Measurement... 17:43:46 Voltage Offset Correction: v_off_ini = -180.861 uV, v_off_fin = -166.411 uV 17:43:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.734 uVs 17:43:49 I2Y Average and RMS of Measurements VT = -269.620 +- 9.997 uVs I2Y = -24.805 +- 0.920 uTm^2 17:43:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm