SLAC Magnetic Measurements Date: 11-07-2025 Time: 13:01:17 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16349 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 13:01:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:27 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:01:29 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:01:30 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:01:32 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:01:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:48 Integrated Voltage Measurement... 13:01:57 Voltage Offset Correction: v_off_ini = -243.975 uV, v_off_fin = -260.583 uV 13:01:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 26.537 uVs 13:01:57 Integrated Voltage Measurement... 13:02:06 Voltage Offset Correction: v_off_ini = -257.275 uV, v_off_fin = -245.144 uV 13:02:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -36.957 uVs 13:02:06 Integrated Voltage Measurement... 13:02:15 Voltage Offset Correction: v_off_ini = -257.267 uV, v_off_fin = -249.129 uV 13:02:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 33.934 uVs 13:02:15 Integrated Voltage Measurement... 13:02:24 Voltage Offset Correction: v_off_ini = -237.216 uV, v_off_fin = -237.892 uV 13:02:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -40.914 uVs 13:02:24 Integrated Voltage Measurement... 13:02:33 Voltage Offset Correction: v_off_ini = -239.395 uV, v_off_fin = -239.976 uV 13:02:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 48.809 uVs 13:02:33 Integrated Voltage Measurement... 13:02:42 Voltage Offset Correction: v_off_ini = -237.463 uV, v_off_fin = -229.459 uV 13:02:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -35.703 uVs 13:02:46 I1X Average and RMS of Measurements VT = 37.142 +- 4.295 uVs I1X = -7.429 +- 0.859 uTm 13:02:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:02:53 Integrated Voltage Measurement... 13:03:02 Voltage Offset Correction: v_off_ini = -216.399 uV, v_off_fin = -227.213 uV 13:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.839 uVs 13:03:02 Integrated Voltage Measurement... 13:03:11 Voltage Offset Correction: v_off_ini = -221.450 uV, v_off_fin = -196.329 uV 13:03:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.262 uVs 13:03:11 Integrated Voltage Measurement... 13:03:20 Voltage Offset Correction: v_off_ini = -211.700 uV, v_off_fin = -207.444 uV 13:03:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.242 uVs 13:03:20 Integrated Voltage Measurement... 13:03:29 Voltage Offset Correction: v_off_ini = -205.000 uV, v_off_fin = -197.986 uV 13:03:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.356 uVs 13:03:29 Integrated Voltage Measurement... 13:03:38 Voltage Offset Correction: v_off_ini = -202.002 uV, v_off_fin = -208.996 uV 13:03:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.833 uVs 13:03:38 Integrated Voltage Measurement... 13:03:47 Voltage Offset Correction: v_off_ini = -190.621 uV, v_off_fin = -174.759 uV 13:03:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.912 uVs 13:03:51 I1Y Average and RMS of Measurements VT = -187.741 +- 2.687 uVs I1Y = -37.546 +- 0.536 uTm 13:03:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:59 Integrated Voltage Measurement... 13:04:08 Voltage Offset Correction: v_off_ini = -193.538 uV, v_off_fin = -207.164 uV 13:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 53.759 uVs 13:04:08 Integrated Voltage Measurement... 13:04:17 Voltage Offset Correction: v_off_ini = -190.586 uV, v_off_fin = -178.686 uV 13:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -25.536 uVs 13:04:17 Integrated Voltage Measurement... 13:04:26 Voltage Offset Correction: v_off_ini = -173.897 uV, v_off_fin = -185.106 uV 13:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 24.715 uVs 13:04:26 Integrated Voltage Measurement... 13:04:35 Voltage Offset Correction: v_off_ini = -178.514 uV, v_off_fin = -168.700 uV 13:04:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -38.790 uVs 13:04:35 Integrated Voltage Measurement... 13:04:44 Voltage Offset Correction: v_off_ini = -177.200 uV, v_off_fin = -190.790 uV 13:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 38.497 uVs 13:04:44 Integrated Voltage Measurement... 13:04:53 Voltage Offset Correction: v_off_ini = -170.195 uV, v_off_fin = -160.568 uV 13:04:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -47.581 uVs 13:04:56 I2X Average and RMS of Measurements VT = 38.146 +- 4.728 uVs I2X = -3.510 +- 0.435 uTm^2 13:05:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:04 Integrated Voltage Measurement... 13:05:13 Voltage Offset Correction: v_off_ini = -177.355 uV, v_off_fin = -176.928 uV 13:05:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.036 uVs 13:05:13 Integrated Voltage Measurement... 13:05:22 Voltage Offset Correction: v_off_ini = -164.765 uV, v_off_fin = -159.170 uV 13:05:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.689 uVs 13:05:22 Integrated Voltage Measurement... 13:05:31 Voltage Offset Correction: v_off_ini = -155.554 uV, v_off_fin = -160.176 uV 13:05:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.625 uVs 13:05:31 Integrated Voltage Measurement... 13:05:40 Voltage Offset Correction: v_off_ini = -164.672 uV, v_off_fin = -172.102 uV 13:05:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.931 uVs 13:05:40 Integrated Voltage Measurement... 13:05:49 Voltage Offset Correction: v_off_ini = -164.481 uV, v_off_fin = -164.771 uV 13:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.117 uVs 13:05:49 Integrated Voltage Measurement... 13:05:58 Voltage Offset Correction: v_off_ini = -165.627 uV, v_off_fin = -172.590 uV 13:05:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.178 uVs 13:06:00 I2Y Average and RMS of Measurements VT = -321.429 +- 1.930 uVs I2Y = -29.571 +- 0.178 uTm^2 13:06:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:15 Integrated Voltage Measurement... 13:06:24 Voltage Offset Correction: v_off_ini = -151.823 uV, v_off_fin = -135.606 uV 13:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 39.188 uVs 13:06:24 Integrated Voltage Measurement... 13:06:33 Voltage Offset Correction: v_off_ini = -151.386 uV, v_off_fin = -137.540 uV 13:06:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -5.262 uVs 13:06:33 Integrated Voltage Measurement... 13:06:42 Voltage Offset Correction: v_off_ini = -147.176 uV, v_off_fin = -152.227 uV 13:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 21.706 uVs 13:06:42 Integrated Voltage Measurement... 13:06:51 Voltage Offset Correction: v_off_ini = -156.181 uV, v_off_fin = -146.807 uV 13:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -5.686 uVs 13:06:51 Integrated Voltage Measurement... 13:07:00 Voltage Offset Correction: v_off_ini = -152.416 uV, v_off_fin = -146.458 uV 13:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 49.981 uVs 13:07:00 Integrated Voltage Measurement... 13:07:09 Voltage Offset Correction: v_off_ini = -136.519 uV, v_off_fin = -143.570 uV 13:07:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -32.220 uVs 13:07:14 I1X Average and RMS of Measurements VT = 25.674 +- 11.451 uVs I1X = -5.135 +- 2.290 uTm 13:07:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:07:20 Integrated Voltage Measurement... 13:07:29 Voltage Offset Correction: v_off_ini = -135.706 uV, v_off_fin = -137.644 uV 13:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.654 uVs 13:07:29 Integrated Voltage Measurement... 13:07:38 Voltage Offset Correction: v_off_ini = -132.598 uV, v_off_fin = -125.374 uV 13:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.854 uVs 13:07:38 Integrated Voltage Measurement... 13:07:47 Voltage Offset Correction: v_off_ini = -141.471 uV, v_off_fin = -139.494 uV 13:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -186.767 uVs 13:07:47 Integrated Voltage Measurement... 13:07:56 Voltage Offset Correction: v_off_ini = -137.957 uV, v_off_fin = -116.368 uV 13:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.864 uVs 13:07:56 Integrated Voltage Measurement... 13:08:05 Voltage Offset Correction: v_off_ini = -124.771 uV, v_off_fin = -132.232 uV 13:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.093 uVs 13:08:05 Integrated Voltage Measurement... 13:08:14 Voltage Offset Correction: v_off_ini = -120.449 uV, v_off_fin = -115.404 uV 13:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.300 uVs 13:08:19 I1Y Average and RMS of Measurements VT = -191.255 +- 1.659 uVs I1Y = -38.249 +- 0.330 uTm 13:08:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:26 Integrated Voltage Measurement... 13:08:35 Voltage Offset Correction: v_off_ini = -126.514 uV, v_off_fin = -133.646 uV 13:08:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 18.471 uVs 13:08:35 Integrated Voltage Measurement... 13:08:44 Voltage Offset Correction: v_off_ini = -121.508 uV, v_off_fin = -110.300 uV 13:08:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -11.181 uVs 13:08:44 Integrated Voltage Measurement... 13:08:53 Voltage Offset Correction: v_off_ini = -126.151 uV, v_off_fin = -135.359 uV 13:08:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 34.798 uVs 13:08:53 Integrated Voltage Measurement... 13:09:02 Voltage Offset Correction: v_off_ini = -125.050 uV, v_off_fin = -111.438 uV 13:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -18.606 uVs 13:09:02 Integrated Voltage Measurement... 13:09:11 Voltage Offset Correction: v_off_ini = -131.500 uV, v_off_fin = -121.682 uV 13:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 9.160 uVs 13:09:11 Integrated Voltage Measurement... 13:09:20 Voltage Offset Correction: v_off_ini = -127.393 uV, v_off_fin = -112.533 uV 13:09:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -14.576 uVs 13:09:23 I2X Average and RMS of Measurements VT = 17.799 +- 6.410 uVs I2X = -1.637 +- 0.590 uTm^2 13:09:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:09:31 Integrated Voltage Measurement... 13:09:40 Voltage Offset Correction: v_off_ini = -111.378 uV, v_off_fin = -121.272 uV 13:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.916 uVs 13:09:40 Integrated Voltage Measurement... 13:09:49 Voltage Offset Correction: v_off_ini = -113.083 uV, v_off_fin = -118.801 uV 13:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.869 uVs 13:09:49 Integrated Voltage Measurement... 13:09:58 Voltage Offset Correction: v_off_ini = -118.317 uV, v_off_fin = -124.833 uV 13:09:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.817 uVs 13:09:58 Integrated Voltage Measurement... 13:10:07 Voltage Offset Correction: v_off_ini = -135.584 uV, v_off_fin = -128.645 uV 13:10:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.051 uVs 13:10:07 Integrated Voltage Measurement... 13:10:16 Voltage Offset Correction: v_off_ini = -121.589 uV, v_off_fin = -120.934 uV 13:10:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.465 uVs 13:10:16 Integrated Voltage Measurement... 13:10:25 Voltage Offset Correction: v_off_ini = -124.914 uV, v_off_fin = -116.203 uV 13:10:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.346 uVs 13:10:27 I2Y Average and RMS of Measurements VT = -305.910 +- 6.583 uVs I2Y = -28.144 +- 0.606 uTm^2 13:10:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:10:42 Integrated Voltage Measurement... 13:10:51 Voltage Offset Correction: v_off_ini = -113.543 uV, v_off_fin = -104.603 uV 13:10:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 14.997 uVs 13:10:51 Integrated Voltage Measurement... 13:11:00 Voltage Offset Correction: v_off_ini = -111.648 uV, v_off_fin = -115.355 uV 13:11:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.866 uVs 13:11:00 Integrated Voltage Measurement... 13:11:09 Voltage Offset Correction: v_off_ini = -106.280 uV, v_off_fin = -118.624 uV 13:11:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 0.929 uVs 13:11:09 Integrated Voltage Measurement... 13:11:18 Voltage Offset Correction: v_off_ini = -120.583 uV, v_off_fin = -108.116 uV 13:11:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -37.473 uVs 13:11:18 Integrated Voltage Measurement... 13:11:27 Voltage Offset Correction: v_off_ini = -124.726 uV, v_off_fin = -117.974 uV 13:11:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 24.878 uVs 13:11:27 Integrated Voltage Measurement... 13:11:36 Voltage Offset Correction: v_off_ini = -115.593 uV, v_off_fin = -98.722 uV 13:11:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -0.678 uVs 13:11:41 I1X Average and RMS of Measurements VT = 11.848 +- 6.417 uVs I1X = -2.370 +- 1.283 uTm 13:11:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:47 Integrated Voltage Measurement... 13:11:56 Voltage Offset Correction: v_off_ini = -122.592 uV, v_off_fin = -118.194 uV 13:11:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.614 uVs 13:11:57 Integrated Voltage Measurement... 13:12:05 Voltage Offset Correction: v_off_ini = -97.094 uV, v_off_fin = -82.627 uV 13:12:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.582 uVs 13:12:06 Integrated Voltage Measurement... 13:12:14 Voltage Offset Correction: v_off_ini = -98.123 uV, v_off_fin = -97.076 uV 13:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.623 uVs 13:12:15 Integrated Voltage Measurement... 13:12:23 Voltage Offset Correction: v_off_ini = -108.735 uV, v_off_fin = -93.429 uV 13:12:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.380 uVs 13:12:24 Integrated Voltage Measurement... 13:12:33 Voltage Offset Correction: v_off_ini = -96.401 uV, v_off_fin = -95.765 uV 13:12:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.335 uVs 13:12:33 Integrated Voltage Measurement... 13:12:42 Voltage Offset Correction: v_off_ini = -89.766 uV, v_off_fin = -75.522 uV 13:12:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.623 uVs 13:12:46 I1Y Average and RMS of Measurements VT = -185.693 +- 2.961 uVs I1Y = -37.138 +- 0.592 uTm 13:12:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:53 Integrated Voltage Measurement... 13:13:02 Voltage Offset Correction: v_off_ini = -95.772 uV, v_off_fin = -91.973 uV 13:13:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 43.976 uVs 13:13:03 Integrated Voltage Measurement... 13:13:12 Voltage Offset Correction: v_off_ini = -87.350 uV, v_off_fin = -74.900 uV 13:13:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -13.636 uVs 13:13:12 Integrated Voltage Measurement... 13:13:21 Voltage Offset Correction: v_off_ini = -81.603 uV, v_off_fin = -86.934 uV 13:13:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 7.266 uVs 13:13:21 Integrated Voltage Measurement... 13:13:30 Voltage Offset Correction: v_off_ini = -81.506 uV, v_off_fin = -68.505 uV 13:13:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -19.289 uVs 13:13:30 Integrated Voltage Measurement... 13:13:39 Voltage Offset Correction: v_off_ini = -78.398 uV, v_off_fin = -78.622 uV 13:13:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 23.689 uVs 13:13:39 Integrated Voltage Measurement... 13:13:48 Voltage Offset Correction: v_off_ini = -85.616 uV, v_off_fin = -87.187 uV 13:13:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -4.080 uVs 13:13:50 I2X Average and RMS of Measurements VT = 18.656 +- 7.181 uVs I2X = -1.716 +- 0.661 uTm^2 13:13:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:58 Integrated Voltage Measurement... 13:14:07 Voltage Offset Correction: v_off_ini = -83.399 uV, v_off_fin = -83.759 uV 13:14:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.262 uVs 13:14:07 Integrated Voltage Measurement... 13:14:16 Voltage Offset Correction: v_off_ini = -83.848 uV, v_off_fin = -86.295 uV 13:14:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.468 uVs 13:14:16 Integrated Voltage Measurement... 13:14:25 Voltage Offset Correction: v_off_ini = -81.649 uV, v_off_fin = -80.235 uV 13:14:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.821 uVs 13:14:25 Integrated Voltage Measurement... 13:14:34 Voltage Offset Correction: v_off_ini = -79.790 uV, v_off_fin = -78.991 uV 13:14:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.494 uVs 13:14:34 Integrated Voltage Measurement... 13:14:43 Voltage Offset Correction: v_off_ini = -82.427 uV, v_off_fin = -76.049 uV 13:14:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.222 uVs 13:14:43 Integrated Voltage Measurement... 13:14:52 Voltage Offset Correction: v_off_ini = -83.395 uV, v_off_fin = -80.412 uV 13:14:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.275 uVs 13:14:55 I2Y Average and RMS of Measurements VT = -305.590 +- 5.775 uVs I2Y = -28.114 +- 0.531 uTm^2 13:15:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:09 Integrated Voltage Measurement... 13:15:18 Voltage Offset Correction: v_off_ini = -74.935 uV, v_off_fin = -78.203 uV 13:15:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -23.237 uVs 13:15:19 Integrated Voltage Measurement... 13:15:27 Voltage Offset Correction: v_off_ini = -69.898 uV, v_off_fin = -57.110 uV 13:15:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -27.253 uVs 13:15:28 Integrated Voltage Measurement... 13:15:37 Voltage Offset Correction: v_off_ini = -64.404 uV, v_off_fin = -64.749 uV 13:15:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 1.315 uVs 13:15:37 Integrated Voltage Measurement... 13:15:46 Voltage Offset Correction: v_off_ini = -71.401 uV, v_off_fin = -60.761 uV 13:15:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -6.264 uVs 13:15:46 Integrated Voltage Measurement... 13:15:55 Voltage Offset Correction: v_off_ini = -75.136 uV, v_off_fin = -67.333 uV 13:15:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 12.439 uVs 13:15:55 Integrated Voltage Measurement... 13:16:04 Voltage Offset Correction: v_off_ini = -79.464 uV, v_off_fin = -75.026 uV 13:16:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 4.033 uVs 13:16:08 I1X Average and RMS of Measurements VT = 3.334 +- 0.952 uVs I1X = -0.667 +- 0.190 uTm 13:16:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:15 Integrated Voltage Measurement... 13:16:24 Voltage Offset Correction: v_off_ini = -58.244 uV, v_off_fin = -76.072 uV 13:16:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.935 uVs 13:16:24 Integrated Voltage Measurement... 13:16:33 Voltage Offset Correction: v_off_ini = -75.779 uV, v_off_fin = -57.346 uV 13:16:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.151 uVs 13:16:33 Integrated Voltage Measurement... 13:16:41 Voltage Offset Correction: v_off_ini = -77.212 uV, v_off_fin = -78.872 uV 13:16:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.651 uVs 13:16:42 Integrated Voltage Measurement... 13:16:50 Voltage Offset Correction: v_off_ini = -80.066 uV, v_off_fin = -57.444 uV 13:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.587 uVs 13:16:51 Integrated Voltage Measurement... 13:16:59 Voltage Offset Correction: v_off_ini = -73.818 uV, v_off_fin = -87.131 uV 13:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.983 uVs 13:17:00 Integrated Voltage Measurement... 13:17:08 Voltage Offset Correction: v_off_ini = -77.700 uV, v_off_fin = -69.397 uV 13:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.489 uVs 13:17:13 I1Y Average and RMS of Measurements VT = -185.466 +- 6.423 uVs I1Y = -37.093 +- 1.285 uTm 13:17:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:20 Integrated Voltage Measurement... 13:17:29 Voltage Offset Correction: v_off_ini = -68.968 uV, v_off_fin = -78.848 uV 13:17:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.672 uVs 13:17:29 Integrated Voltage Measurement... 13:17:38 Voltage Offset Correction: v_off_ini = -64.121 uV, v_off_fin = -53.848 uV 13:17:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.857 uVs 13:17:38 Integrated Voltage Measurement... 13:17:47 Voltage Offset Correction: v_off_ini = -69.444 uV, v_off_fin = -84.585 uV 13:17:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 11.668 uVs 13:17:47 Integrated Voltage Measurement... 13:17:56 Voltage Offset Correction: v_off_ini = -67.835 uV, v_off_fin = -51.262 uV 13:17:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.994 uVs 13:17:57 Integrated Voltage Measurement... 13:18:05 Voltage Offset Correction: v_off_ini = -63.488 uV, v_off_fin = -65.753 uV 13:18:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 12.161 uVs 13:18:06 Integrated Voltage Measurement... 13:18:14 Voltage Offset Correction: v_off_ini = -57.616 uV, v_off_fin = -55.901 uV 13:18:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -17.869 uVs 13:18:17 I2X Average and RMS of Measurements VT = 9.537 +- 3.874 uVs I2X = -0.877 +- 0.356 uTm^2 13:18:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:18:25 Integrated Voltage Measurement... 13:18:34 Voltage Offset Correction: v_off_ini = -81.529 uV, v_off_fin = -73.681 uV 13:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.748 uVs 13:18:34 Integrated Voltage Measurement... 13:18:43 Voltage Offset Correction: v_off_ini = -61.257 uV, v_off_fin = -65.250 uV 13:18:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.310 uVs 13:18:43 Integrated Voltage Measurement... 13:18:52 Voltage Offset Correction: v_off_ini = -72.185 uV, v_off_fin = -75.226 uV 13:18:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.048 uVs 13:18:52 Integrated Voltage Measurement... 13:19:01 Voltage Offset Correction: v_off_ini = -87.029 uV, v_off_fin = -63.874 uV 13:19:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.134 uVs 13:19:01 Integrated Voltage Measurement... 13:19:10 Voltage Offset Correction: v_off_ini = -70.413 uV, v_off_fin = -62.458 uV 13:19:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.389 uVs 13:19:10 Integrated Voltage Measurement... 13:19:19 Voltage Offset Correction: v_off_ini = -71.555 uV, v_off_fin = -61.124 uV 13:19:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.867 uVs 13:19:21 I2Y Average and RMS of Measurements VT = -289.416 +- 7.172 uVs I2Y = -26.626 +- 0.660 uTm^2 13:19:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:36 Integrated Voltage Measurement... 13:19:45 Voltage Offset Correction: v_off_ini = -83.596 uV, v_off_fin = -103.614 uV 13:19:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -5.348 uVs 13:19:45 Integrated Voltage Measurement... 13:19:54 Voltage Offset Correction: v_off_ini = -84.703 uV, v_off_fin = -84.504 uV 13:19:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 6.219 uVs 13:19:54 Integrated Voltage Measurement... 13:20:03 Voltage Offset Correction: v_off_ini = -76.421 uV, v_off_fin = -85.381 uV 13:20:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -1.317 uVs 13:20:03 Integrated Voltage Measurement... 13:20:12 Voltage Offset Correction: v_off_ini = -86.648 uV, v_off_fin = -79.551 uV 13:20:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -1.565 uVs 13:20:12 Integrated Voltage Measurement... 13:20:21 Voltage Offset Correction: v_off_ini = -108.428 uV, v_off_fin = -101.410 uV 13:20:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 17.722 uVs 13:20:21 Integrated Voltage Measurement... 13:20:30 Voltage Offset Correction: v_off_ini = -88.529 uV, v_off_fin = -76.519 uV 13:20:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -6.328 uVs 13:20:34 I1X Average and RMS of Measurements VT = 2.122 +- 7.406 uVs I1X = -0.424 +- 1.481 uTm 13:20:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:20:41 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = -91.257 uV, v_off_fin = -111.188 uV 13:20:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -172.364 uVs 13:20:50 Integrated Voltage Measurement... 13:20:59 Voltage Offset Correction: v_off_ini = -98.219 uV, v_off_fin = -77.313 uV 13:20:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.071 uVs 13:20:59 Integrated Voltage Measurement... 13:21:08 Voltage Offset Correction: v_off_ini = -92.735 uV, v_off_fin = -96.841 uV 13:21:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.708 uVs 13:21:08 Integrated Voltage Measurement... 13:21:17 Voltage Offset Correction: v_off_ini = -82.820 uV, v_off_fin = -66.864 uV 13:21:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.341 uVs 13:21:17 Integrated Voltage Measurement... 13:21:26 Voltage Offset Correction: v_off_ini = -87.911 uV, v_off_fin = -103.193 uV 13:21:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.422 uVs 13:21:26 Integrated Voltage Measurement... 13:21:35 Voltage Offset Correction: v_off_ini = -81.463 uV, v_off_fin = -67.474 uV 13:21:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.130 uVs 13:21:39 I1Y Average and RMS of Measurements VT = -180.006 +- 3.508 uVs I1Y = -36.001 +- 0.701 uTm 13:21:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:47 Integrated Voltage Measurement... 13:21:56 Voltage Offset Correction: v_off_ini = -77.289 uV, v_off_fin = -82.587 uV 13:21:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.508 uVs 13:21:56 Integrated Voltage Measurement... 13:22:05 Voltage Offset Correction: v_off_ini = -72.339 uV, v_off_fin = -69.704 uV 13:22:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.752 uVs 13:22:05 Integrated Voltage Measurement... 13:22:14 Voltage Offset Correction: v_off_ini = -74.332 uV, v_off_fin = -72.834 uV 13:22:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.055 uVs 13:22:14 Integrated Voltage Measurement... 13:22:23 Voltage Offset Correction: v_off_ini = -80.771 uV, v_off_fin = -52.242 uV 13:22:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.639 uVs 13:22:23 Integrated Voltage Measurement... 13:22:32 Voltage Offset Correction: v_off_ini = -72.233 uV, v_off_fin = -77.388 uV 13:22:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -11.658 uVs 13:22:32 Integrated Voltage Measurement... 13:22:41 Voltage Offset Correction: v_off_ini = -78.592 uV, v_off_fin = -63.217 uV 13:22:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.633 uVs 13:22:43 I2X Average and RMS of Measurements VT = -7.163 +- 3.622 uVs I2X = 0.659 +- 0.333 uTm^2 13:22:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:22:51 Integrated Voltage Measurement... 13:23:00 Voltage Offset Correction: v_off_ini = -81.287 uV, v_off_fin = -88.560 uV 13:23:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.226 uVs 13:23:00 Integrated Voltage Measurement... 13:23:09 Voltage Offset Correction: v_off_ini = -86.506 uV, v_off_fin = -86.444 uV 13:23:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.708 uVs 13:23:09 Integrated Voltage Measurement... 13:23:18 Voltage Offset Correction: v_off_ini = -90.111 uV, v_off_fin = -92.073 uV 13:23:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.422 uVs 13:23:18 Integrated Voltage Measurement... 13:23:27 Voltage Offset Correction: v_off_ini = -94.368 uV, v_off_fin = -107.840 uV 13:23:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.448 uVs 13:23:27 Integrated Voltage Measurement... 13:23:36 Voltage Offset Correction: v_off_ini = -99.422 uV, v_off_fin = -103.771 uV 13:23:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.044 uVs 13:23:36 Integrated Voltage Measurement... 13:23:45 Voltage Offset Correction: v_off_ini = -114.371 uV, v_off_fin = -95.080 uV 13:23:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.169 uVs 13:23:48 I2Y Average and RMS of Measurements VT = -289.670 +- 8.995 uVs I2Y = -26.650 +- 0.828 uTm^2 13:23:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:03 Integrated Voltage Measurement... 13:24:11 Voltage Offset Correction: v_off_ini = -88.803 uV, v_off_fin = -85.844 uV 13:24:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = 9.367 uVs 13:24:12 Integrated Voltage Measurement... 13:24:20 Voltage Offset Correction: v_off_ini = -91.705 uV, v_off_fin = -82.124 uV 13:24:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.690 uVs 13:24:21 Integrated Voltage Measurement... 13:24:29 Voltage Offset Correction: v_off_ini = -75.970 uV, v_off_fin = -73.122 uV 13:24:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.742 uVs 13:24:30 Integrated Voltage Measurement... 13:24:38 Voltage Offset Correction: v_off_ini = -76.933 uV, v_off_fin = -75.260 uV 13:24:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.899 uVs 13:24:39 Integrated Voltage Measurement... 13:24:48 Voltage Offset Correction: v_off_ini = -79.485 uV, v_off_fin = -92.267 uV 13:24:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 1.188 uVs 13:24:48 Integrated Voltage Measurement... 13:24:57 Voltage Offset Correction: v_off_ini = -84.880 uV, v_off_fin = -70.838 uV 13:24:57 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 14.745 uVs 13:25:01 I1X Average and RMS of Measurements VT = -13.920 +- 5.553 uVs I1X = 2.784 +- 1.110 uTm 13:25:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:08 Integrated Voltage Measurement... 13:25:16 Voltage Offset Correction: v_off_ini = -74.175 uV, v_off_fin = -84.968 uV 13:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.725 uVs 13:25:17 Integrated Voltage Measurement... 13:25:25 Voltage Offset Correction: v_off_ini = -69.548 uV, v_off_fin = -41.495 uV 13:25:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.095 uVs 13:25:26 Integrated Voltage Measurement... 13:25:34 Voltage Offset Correction: v_off_ini = -65.355 uV, v_off_fin = -70.806 uV 13:25:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.927 uVs 13:25:34 Integrated Voltage Measurement... 13:25:43 Voltage Offset Correction: v_off_ini = -62.113 uV, v_off_fin = -56.148 uV 13:25:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.402 uVs 13:25:43 Integrated Voltage Measurement... 13:25:52 Voltage Offset Correction: v_off_ini = -68.190 uV, v_off_fin = -64.917 uV 13:25:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.487 uVs 13:25:52 Integrated Voltage Measurement... 13:26:01 Voltage Offset Correction: v_off_ini = -49.656 uV, v_off_fin = -28.662 uV 13:26:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.143 uVs 13:26:06 I1Y Average and RMS of Measurements VT = -175.963 +- 6.508 uVs I1Y = -35.191 +- 1.301 uTm 13:26:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:26:13 Integrated Voltage Measurement... 13:26:22 Voltage Offset Correction: v_off_ini = -52.066 uV, v_off_fin = -47.045 uV 13:26:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -18.791 uVs 13:26:22 Integrated Voltage Measurement... 13:26:31 Voltage Offset Correction: v_off_ini = -48.956 uV, v_off_fin = -40.367 uV 13:26:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.372 uVs 13:26:31 Integrated Voltage Measurement... 13:26:40 Voltage Offset Correction: v_off_ini = -47.045 uV, v_off_fin = -57.711 uV 13:26:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.640 uVs 13:26:40 Integrated Voltage Measurement... 13:26:49 Voltage Offset Correction: v_off_ini = -54.040 uV, v_off_fin = -32.287 uV 13:26:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.403 uVs 13:26:49 Integrated Voltage Measurement... 13:26:58 Voltage Offset Correction: v_off_ini = -28.885 uV, v_off_fin = -46.261 uV 13:26:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.850 uVs 13:26:58 Integrated Voltage Measurement... 13:27:07 Voltage Offset Correction: v_off_ini = -28.265 uV, v_off_fin = -32.697 uV 13:27:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.494 uVs 13:27:10 I2X Average and RMS of Measurements VT = -13.927 +- 6.925 uVs I2X = 1.281 +- 0.637 uTm^2 13:27:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:17 Integrated Voltage Measurement... 13:27:26 Voltage Offset Correction: v_off_ini = -25.039 uV, v_off_fin = -22.568 uV 13:27:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -280.560 uVs 13:27:27 Integrated Voltage Measurement... 13:27:35 Voltage Offset Correction: v_off_ini = -27.574 uV, v_off_fin = -29.895 uV 13:27:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.348 uVs 13:27:36 Integrated Voltage Measurement... 13:27:45 Voltage Offset Correction: v_off_ini = -24.051 uV, v_off_fin = -22.322 uV 13:27:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.127 uVs 13:27:45 Integrated Voltage Measurement... 13:27:54 Voltage Offset Correction: v_off_ini = -40.465 uV, v_off_fin = -37.730 uV 13:27:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.894 uVs 13:27:54 Integrated Voltage Measurement... 13:28:03 Voltage Offset Correction: v_off_ini = -30.286 uV, v_off_fin = -32.159 uV 13:28:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.586 uVs 13:28:03 Integrated Voltage Measurement... 13:28:12 Voltage Offset Correction: v_off_ini = -15.092 uV, v_off_fin = -28.283 uV 13:28:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.406 uVs 13:28:14 I2Y Average and RMS of Measurements VT = -281.320 +- 7.542 uVs I2Y = -25.882 +- 0.694 uTm^2 13:28:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:29 Integrated Voltage Measurement... 13:28:38 Voltage Offset Correction: v_off_ini = -23.916 uV, v_off_fin = -36.275 uV 13:28:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -2.387 uVs 13:28:38 Integrated Voltage Measurement... 13:28:47 Voltage Offset Correction: v_off_ini = -32.023 uV, v_off_fin = -31.828 uV 13:28:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -5.736 uVs 13:28:47 Integrated Voltage Measurement... 13:28:56 Voltage Offset Correction: v_off_ini = -31.068 uV, v_off_fin = -29.407 uV 13:28:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -23.927 uVs 13:28:56 Integrated Voltage Measurement... 13:29:05 Voltage Offset Correction: v_off_ini = -35.555 uV, v_off_fin = -24.884 uV 13:29:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 9.122 uVs 13:29:05 Integrated Voltage Measurement... 13:29:14 Voltage Offset Correction: v_off_ini = -40.868 uV, v_off_fin = -27.126 uV 13:29:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -19.283 uVs 13:29:14 Integrated Voltage Measurement... 13:29:23 Voltage Offset Correction: v_off_ini = -17.546 uV, v_off_fin = -8.926 uV 13:29:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.595 uVs 13:29:27 I1X Average and RMS of Measurements VT = -9.430 +- 7.952 uVs I1X = 1.886 +- 1.590 uTm 13:29:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:29:34 Integrated Voltage Measurement... 13:29:43 Voltage Offset Correction: v_off_ini = -33.306 uV, v_off_fin = -40.752 uV 13:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.311 uVs 13:29:43 Integrated Voltage Measurement... 13:29:52 Voltage Offset Correction: v_off_ini = -36.996 uV, v_off_fin = -18.864 uV 13:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.955 uVs 13:29:52 Integrated Voltage Measurement... 13:30:01 Voltage Offset Correction: v_off_ini = -32.701 uV, v_off_fin = -30.387 uV 13:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.700 uVs 13:30:01 Integrated Voltage Measurement... 13:30:10 Voltage Offset Correction: v_off_ini = -33.609 uV, v_off_fin = -15.174 uV 13:30:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.586 uVs 13:30:10 Integrated Voltage Measurement... 13:30:19 Voltage Offset Correction: v_off_ini = -17.113 uV, v_off_fin = -40.900 uV 13:30:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.337 uVs 13:30:19 Integrated Voltage Measurement... 13:30:28 Voltage Offset Correction: v_off_ini = -26.564 uV, v_off_fin = -10.706 uV 13:30:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.971 uVs 13:30:32 I1Y Average and RMS of Measurements VT = -186.310 +- 2.902 uVs I1Y = -37.260 +- 0.580 uTm 13:30:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:30:40 Integrated Voltage Measurement... 13:30:49 Voltage Offset Correction: v_off_ini = -22.904 uV, v_off_fin = -32.216 uV 13:30:49 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -13.211 uVs 13:30:49 Integrated Voltage Measurement... 13:30:58 Voltage Offset Correction: v_off_ini = -19.531 uV, v_off_fin = -24.319 uV 13:30:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -12.926 uVs 13:30:58 Integrated Voltage Measurement... 13:31:07 Voltage Offset Correction: v_off_ini = -40.666 uV, v_off_fin = -44.137 uV 13:31:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.620 uVs 13:31:07 Integrated Voltage Measurement... 13:31:16 Voltage Offset Correction: v_off_ini = -28.221 uV, v_off_fin = -26.621 uV 13:31:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.221 uVs 13:31:16 Integrated Voltage Measurement... 13:31:25 Voltage Offset Correction: v_off_ini = -34.225 uV, v_off_fin = -49.646 uV 13:31:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 0.454 uVs 13:31:25 Integrated Voltage Measurement... 13:31:34 Voltage Offset Correction: v_off_ini = -40.868 uV, v_off_fin = -34.814 uV 13:31:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.710 uVs 13:31:36 I2X Average and RMS of Measurements VT = -9.897 +- 6.961 uVs I2X = 0.910 +- 0.640 uTm^2 13:31:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:31:44 Integrated Voltage Measurement... 13:31:53 Voltage Offset Correction: v_off_ini = -34.518 uV, v_off_fin = -37.407 uV 13:31:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.193 uVs 13:31:53 Integrated Voltage Measurement... 13:32:02 Voltage Offset Correction: v_off_ini = -35.160 uV, v_off_fin = -40.926 uV 13:32:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.818 uVs 13:32:02 Integrated Voltage Measurement... 13:32:11 Voltage Offset Correction: v_off_ini = -36.201 uV, v_off_fin = -34.605 uV 13:32:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.990 uVs 13:32:11 Integrated Voltage Measurement... 13:32:20 Voltage Offset Correction: v_off_ini = -39.883 uV, v_off_fin = -44.094 uV 13:32:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.362 uVs 13:32:20 Integrated Voltage Measurement... 13:32:29 Voltage Offset Correction: v_off_ini = -31.850 uV, v_off_fin = -36.144 uV 13:32:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.271 uVs 13:32:29 Integrated Voltage Measurement... 13:32:38 Voltage Offset Correction: v_off_ini = -38.351 uV, v_off_fin = -41.476 uV 13:32:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.317 uVs 13:32:40 I2Y Average and RMS of Measurements VT = -280.492 +- 6.018 uVs I2Y = -25.805 +- 0.554 uTm^2 13:32:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:55 Integrated Voltage Measurement... 13:33:04 Voltage Offset Correction: v_off_ini = -25.237 uV, v_off_fin = -39.047 uV 13:33:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -3.507 uVs 13:33:04 Integrated Voltage Measurement... 13:33:13 Voltage Offset Correction: v_off_ini = -22.269 uV, v_off_fin = -28.103 uV 13:33:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -7.197 uVs 13:33:13 Integrated Voltage Measurement... 13:33:22 Voltage Offset Correction: v_off_ini = -43.327 uV, v_off_fin = -39.332 uV 13:33:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -8.930 uVs 13:33:22 Integrated Voltage Measurement... 13:33:31 Voltage Offset Correction: v_off_ini = -29.119 uV, v_off_fin = -26.904 uV 13:33:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 9.315 uVs 13:33:32 Integrated Voltage Measurement... 13:33:40 Voltage Offset Correction: v_off_ini = -34.806 uV, v_off_fin = -36.202 uV 13:33:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.700 uVs 13:33:41 Integrated Voltage Measurement... 13:33:49 Voltage Offset Correction: v_off_ini = -35.338 uV, v_off_fin = -28.971 uV 13:33:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.421 uVs 13:33:54 I1X Average and RMS of Measurements VT = -7.779 +- 7.371 uVs I1X = 1.556 +- 1.474 uTm 13:33:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:01 Integrated Voltage Measurement... 13:34:09 Voltage Offset Correction: v_off_ini = -35.004 uV, v_off_fin = -26.489 uV 13:34:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.680 uVs 13:34:10 Integrated Voltage Measurement... 13:34:18 Voltage Offset Correction: v_off_ini = -22.182 uV, v_off_fin = -13.586 uV 13:34:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.682 uVs 13:34:19 Integrated Voltage Measurement... 13:34:27 Voltage Offset Correction: v_off_ini = -18.072 uV, v_off_fin = -33.923 uV 13:34:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.296 uVs 13:34:28 Integrated Voltage Measurement... 13:34:36 Voltage Offset Correction: v_off_ini = -25.296 uV, v_off_fin = -13.436 uV 13:34:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.413 uVs 13:34:37 Integrated Voltage Measurement... 13:34:45 Voltage Offset Correction: v_off_ini = -33.965 uV, v_off_fin = -37.497 uV 13:34:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.882 uVs 13:34:46 Integrated Voltage Measurement... 13:34:54 Voltage Offset Correction: v_off_ini = -22.230 uV, v_off_fin = -14.056 uV 13:34:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.521 uVs 13:34:59 I1Y Average and RMS of Measurements VT = -172.746 +- 5.761 uVs I1Y = -34.548 +- 1.152 uTm 13:35:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:06 Integrated Voltage Measurement... 13:35:15 Voltage Offset Correction: v_off_ini = -42.994 uV, v_off_fin = -33.885 uV 13:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.101 uVs 13:35:15 Integrated Voltage Measurement... 13:35:24 Voltage Offset Correction: v_off_ini = -26.504 uV, v_off_fin = -19.897 uV 13:35:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.348 uVs 13:35:25 Integrated Voltage Measurement... 13:35:33 Voltage Offset Correction: v_off_ini = -40.499 uV, v_off_fin = -41.593 uV 13:35:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -9.246 uVs 13:35:34 Integrated Voltage Measurement... 13:35:43 Voltage Offset Correction: v_off_ini = -41.494 uV, v_off_fin = -18.842 uV 13:35:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.974 uVs 13:35:43 Integrated Voltage Measurement... 13:35:52 Voltage Offset Correction: v_off_ini = -21.856 uV, v_off_fin = -52.106 uV 13:35:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -20.216 uVs 13:35:52 Integrated Voltage Measurement... 13:36:01 Voltage Offset Correction: v_off_ini = -34.013 uV, v_off_fin = -20.722 uV 13:36:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.107 uVs 13:36:03 I2X Average and RMS of Measurements VT = -23.999 +- 1.054 uVs I2X = 2.208 +- 0.097 uTm^2 13:36:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:11 Integrated Voltage Measurement... 13:36:20 Voltage Offset Correction: v_off_ini = -33.167 uV, v_off_fin = -23.561 uV 13:36:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.603 uVs 13:36:20 Integrated Voltage Measurement... 13:36:29 Voltage Offset Correction: v_off_ini = -24.845 uV, v_off_fin = -27.738 uV 13:36:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.073 uVs 13:36:29 Integrated Voltage Measurement... 13:36:38 Voltage Offset Correction: v_off_ini = -31.099 uV, v_off_fin = -31.838 uV 13:36:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.697 uVs 13:36:38 Integrated Voltage Measurement... 13:36:47 Voltage Offset Correction: v_off_ini = -25.616 uV, v_off_fin = -27.294 uV 13:36:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.254 uVs 13:36:47 Integrated Voltage Measurement... 13:36:56 Voltage Offset Correction: v_off_ini = -22.720 uV, v_off_fin = -29.830 uV 13:36:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.183 uVs 13:36:56 Integrated Voltage Measurement... 13:37:05 Voltage Offset Correction: v_off_ini = -33.903 uV, v_off_fin = -38.495 uV 13:37:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.792 uVs 13:37:07 I2Y Average and RMS of Measurements VT = -260.767 +- 10.029 uVs I2Y = -23.991 +- 0.923 uTm^2 13:37:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:22 Integrated Voltage Measurement... 13:37:31 Voltage Offset Correction: v_off_ini = -2.028 uV, v_off_fin = -26.748 uV 13:37:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.720 uVs 13:37:31 Integrated Voltage Measurement... 13:37:40 Voltage Offset Correction: v_off_ini = -12.496 uV, v_off_fin = -6.122 uV 13:37:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.486 uVs 13:37:40 Integrated Voltage Measurement... 13:37:49 Voltage Offset Correction: v_off_ini = -10.283 uV, v_off_fin = -10.976 uV 13:37:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.576 uVs 13:37:49 Integrated Voltage Measurement... 13:37:58 Voltage Offset Correction: v_off_ini = -17.451 uV, v_off_fin = -4.427 uV 13:37:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.899 uVs 13:37:58 Integrated Voltage Measurement... 13:38:07 Voltage Offset Correction: v_off_ini = -19.951 uV, v_off_fin = -30.667 uV 13:38:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.413 uVs 13:38:07 Integrated Voltage Measurement... 13:38:16 Voltage Offset Correction: v_off_ini = -32.290 uV, v_off_fin = -21.008 uV 13:38:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.190 uVs 13:38:21 I1X Average and RMS of Measurements VT = -36.214 +- 6.800 uVs I1X = 7.243 +- 1.360 uTm 13:38:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:27 Integrated Voltage Measurement... 13:38:36 Voltage Offset Correction: v_off_ini = -27.315 uV, v_off_fin = -36.159 uV 13:38:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -153.231 uVs 13:38:36 Integrated Voltage Measurement... 13:38:45 Voltage Offset Correction: v_off_ini = -19.487 uV, v_off_fin = -5.840 uV 13:38:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.672 uVs 13:38:45 Integrated Voltage Measurement... 13:38:54 Voltage Offset Correction: v_off_ini = -23.013 uV, v_off_fin = -30.973 uV 13:38:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.583 uVs 13:38:54 Integrated Voltage Measurement... 13:39:03 Voltage Offset Correction: v_off_ini = -15.942 uV, v_off_fin = 3.677 uV 13:39:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.559 uVs 13:39:03 Integrated Voltage Measurement... 13:39:12 Voltage Offset Correction: v_off_ini = -5.044 uV, v_off_fin = -22.869 uV 13:39:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.804 uVs 13:39:12 Integrated Voltage Measurement... 13:39:21 Voltage Offset Correction: v_off_ini = -15.451 uV, v_off_fin = -8.403 uV 13:39:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.895 uVs 13:39:26 I1Y Average and RMS of Measurements VT = -172.291 +- 11.405 uVs I1Y = -34.456 +- 2.280 uTm 13:39:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:33 Integrated Voltage Measurement... 13:39:42 Voltage Offset Correction: v_off_ini = -32.267 uV, v_off_fin = -17.602 uV 13:39:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 5.607 uVs 13:39:42 Integrated Voltage Measurement... 13:39:51 Voltage Offset Correction: v_off_ini = -9.867 uV, v_off_fin = 0.734 uV 13:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.163 uVs 13:39:51 Integrated Voltage Measurement... 13:40:00 Voltage Offset Correction: v_off_ini = -18.790 uV, v_off_fin = -29.750 uV 13:40:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.545 uVs 13:40:00 Integrated Voltage Measurement... 13:40:09 Voltage Offset Correction: v_off_ini = -26.696 uV, v_off_fin = -7.787 uV 13:40:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.610 uVs 13:40:09 Integrated Voltage Measurement... 13:40:18 Voltage Offset Correction: v_off_ini = -11.817 uV, v_off_fin = -25.996 uV 13:40:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.236 uVs 13:40:19 Integrated Voltage Measurement... 13:40:27 Voltage Offset Correction: v_off_ini = -20.072 uV, v_off_fin = -15.577 uV 13:40:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.763 uVs 13:40:30 I2X Average and RMS of Measurements VT = -21.951 +- 11.490 uVs I2X = 2.020 +- 1.057 uTm^2 13:40:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:40:38 Integrated Voltage Measurement... 13:40:47 Voltage Offset Correction: v_off_ini = -21.377 uV, v_off_fin = -20.604 uV 13:40:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -257.508 uVs 13:40:47 Integrated Voltage Measurement... 13:40:56 Voltage Offset Correction: v_off_ini = -16.506 uV, v_off_fin = -27.827 uV 13:40:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.783 uVs 13:40:56 Integrated Voltage Measurement... 13:41:05 Voltage Offset Correction: v_off_ini = -22.980 uV, v_off_fin = -27.240 uV 13:41:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.133 uVs 13:41:05 Integrated Voltage Measurement... 13:41:14 Voltage Offset Correction: v_off_ini = -17.304 uV, v_off_fin = -12.433 uV 13:41:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.837 uVs 13:41:14 Integrated Voltage Measurement... 13:41:23 Voltage Offset Correction: v_off_ini = -8.225 uV, v_off_fin = -11.324 uV 13:41:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.145 uVs 13:41:23 Integrated Voltage Measurement... 13:41:32 Voltage Offset Correction: v_off_ini = -11.035 uV, v_off_fin = -10.685 uV 13:41:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.951 uVs 13:41:34 I2Y Average and RMS of Measurements VT = -267.726 +- 10.394 uVs I2Y = -24.631 +- 0.956 uTm^2 13:41:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:41:49 Integrated Voltage Measurement... 13:41:58 Voltage Offset Correction: v_off_ini = -7.100 uV, v_off_fin = -12.865 uV 13:41:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.332 uVs 13:41:58 Integrated Voltage Measurement... 13:42:07 Voltage Offset Correction: v_off_ini = -1.494 uV, v_off_fin = -11.464 uV 13:42:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.654 uVs 13:42:07 Integrated Voltage Measurement... 13:42:16 Voltage Offset Correction: v_off_ini = -8.225 uV, v_off_fin = -24.709 uV 13:42:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.263 uVs 13:42:16 Integrated Voltage Measurement... 13:42:25 Voltage Offset Correction: v_off_ini = -1.984 uV, v_off_fin = -20.203 uV 13:42:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.858 uVs 13:42:25 Integrated Voltage Measurement... 13:42:34 Voltage Offset Correction: v_off_ini = -0.384 uV, v_off_fin = -12.142 uV 13:42:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.333 uVs 13:42:34 Integrated Voltage Measurement... 13:42:43 Voltage Offset Correction: v_off_ini = -10.549 uV, v_off_fin = 1.068 uV 13:42:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 3.811 uVs 13:42:48 I1X Average and RMS of Measurements VT = -25.209 +- 7.521 uVs I1X = 5.042 +- 1.504 uTm 13:42:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:54 Integrated Voltage Measurement... 13:43:03 Voltage Offset Correction: v_off_ini = -20.643 uV, v_off_fin = -28.497 uV 13:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.187 uVs 13:43:03 Integrated Voltage Measurement... 13:43:12 Voltage Offset Correction: v_off_ini = -17.585 uV, v_off_fin = -11.489 uV 13:43:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.965 uVs 13:43:12 Integrated Voltage Measurement... 13:43:21 Voltage Offset Correction: v_off_ini = -12.437 uV, v_off_fin = -25.556 uV 13:43:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.756 uVs 13:43:21 Integrated Voltage Measurement... 13:43:30 Voltage Offset Correction: v_off_ini = -27.309 uV, v_off_fin = -23.418 uV 13:43:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.978 uVs 13:43:30 Integrated Voltage Measurement... 13:43:39 Voltage Offset Correction: v_off_ini = -21.677 uV, v_off_fin = -29.904 uV 13:43:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.154 uVs 13:43:39 Integrated Voltage Measurement... 13:43:48 Voltage Offset Correction: v_off_ini = -23.040 uV, v_off_fin = -18.699 uV 13:43:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.331 uVs 13:43:53 I1Y Average and RMS of Measurements VT = -169.728 +- 4.968 uVs I1Y = -33.945 +- 0.994 uTm 13:43:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:00 Integrated Voltage Measurement... 13:44:09 Voltage Offset Correction: v_off_ini = -33.509 uV, v_off_fin = -30.217 uV 13:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.084 uVs 13:44:09 Integrated Voltage Measurement... 13:44:18 Voltage Offset Correction: v_off_ini = -25.353 uV, v_off_fin = -14.409 uV 13:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.543 uVs 13:44:18 Integrated Voltage Measurement... 13:44:27 Voltage Offset Correction: v_off_ini = -19.649 uV, v_off_fin = -26.043 uV 13:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.188 uVs 13:44:27 Integrated Voltage Measurement... 13:44:36 Voltage Offset Correction: v_off_ini = -23.149 uV, v_off_fin = -14.491 uV 13:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.064 uVs 13:44:36 Integrated Voltage Measurement... 13:44:45 Voltage Offset Correction: v_off_ini = -13.043 uV, v_off_fin = -24.179 uV 13:44:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.281 uVs 13:44:45 Integrated Voltage Measurement... 13:44:54 Voltage Offset Correction: v_off_ini = -13.995 uV, v_off_fin = -9.505 uV 13:44:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.199 uVs 13:44:57 I2X Average and RMS of Measurements VT = -33.393 +- 2.293 uVs I2X = 3.072 +- 0.211 uTm^2 13:45:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:05 Integrated Voltage Measurement... 13:45:14 Voltage Offset Correction: v_off_ini = 4.545 uV, v_off_fin = -4.094 uV 13:45:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.587 uVs 13:45:14 Integrated Voltage Measurement... 13:45:23 Voltage Offset Correction: v_off_ini = 2.365 uV, v_off_fin = 4.559 uV 13:45:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.474 uVs 13:45:23 Integrated Voltage Measurement... 13:45:32 Voltage Offset Correction: v_off_ini = 6.296 uV, v_off_fin = 3.116 uV 13:45:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.664 uVs 13:45:32 Integrated Voltage Measurement... 13:45:41 Voltage Offset Correction: v_off_ini = 10.005 uV, v_off_fin = 1.338 uV 13:45:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.430 uVs 13:45:41 Integrated Voltage Measurement... 13:45:50 Voltage Offset Correction: v_off_ini = -15.941 uV, v_off_fin = -2.149 uV 13:45:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.735 uVs 13:45:50 Integrated Voltage Measurement... 13:45:59 Voltage Offset Correction: v_off_ini = -6.266 uV, v_off_fin = 0.893 uV 13:45:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.338 uVs 13:46:01 I2Y Average and RMS of Measurements VT = -261.038 +- 2.127 uVs I2Y = -24.015 +- 0.196 uTm^2 13:46:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:16 Integrated Voltage Measurement... 13:46:25 Voltage Offset Correction: v_off_ini = -15.752 uV, v_off_fin = -21.376 uV 13:46:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -49.998 uVs 13:46:25 Integrated Voltage Measurement... 13:46:34 Voltage Offset Correction: v_off_ini = -20.351 uV, v_off_fin = -15.251 uV 13:46:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.625 uVs 13:46:34 Integrated Voltage Measurement... 13:46:43 Voltage Offset Correction: v_off_ini = -17.074 uV, v_off_fin = -21.183 uV 13:46:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.257 uVs 13:46:43 Integrated Voltage Measurement... 13:46:52 Voltage Offset Correction: v_off_ini = 2.508 uV, v_off_fin = -17.417 uV 13:46:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 14.898 uVs 13:46:52 Integrated Voltage Measurement... 13:47:01 Voltage Offset Correction: v_off_ini = -16.667 uV, v_off_fin = -9.387 uV 13:47:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -16.406 uVs 13:47:01 Integrated Voltage Measurement... 13:47:10 Voltage Offset Correction: v_off_ini = -12.006 uV, v_off_fin = -16.203 uV 13:47:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.210 uVs 13:47:14 I1X Average and RMS of Measurements VT = -27.899 +- 7.954 uVs I1X = 5.580 +- 1.591 uTm 13:47:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:21 Integrated Voltage Measurement... 13:47:30 Voltage Offset Correction: v_off_ini = -46.028 uV, v_off_fin = -24.563 uV 13:47:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.278 uVs 13:47:30 Integrated Voltage Measurement... 13:47:39 Voltage Offset Correction: v_off_ini = -12.304 uV, v_off_fin = 8.275 uV 13:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 166.979 uVs 13:47:39 Integrated Voltage Measurement... 13:47:48 Voltage Offset Correction: v_off_ini = -16.183 uV, v_off_fin = -26.890 uV 13:47:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.444 uVs 13:47:48 Integrated Voltage Measurement... 13:47:57 Voltage Offset Correction: v_off_ini = -15.372 uV, v_off_fin = -13.161 uV 13:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.243 uVs 13:47:57 Integrated Voltage Measurement... 13:48:06 Voltage Offset Correction: v_off_ini = -20.073 uV, v_off_fin = -26.004 uV 13:48:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.228 uVs 13:48:06 Integrated Voltage Measurement... 13:48:15 Voltage Offset Correction: v_off_ini = -27.426 uV, v_off_fin = -11.172 uV 13:48:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 174.020 uVs 13:48:19 I1Y Average and RMS of Measurements VT = -168.532 +- 8.258 uVs I1Y = -33.704 +- 1.651 uTm 13:48:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:27 Integrated Voltage Measurement... 13:48:36 Voltage Offset Correction: v_off_ini = -28.557 uV, v_off_fin = -27.104 uV 13:48:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -32.080 uVs 13:48:36 Integrated Voltage Measurement...