SLAC Magnetic Measurements Date: 11-07-2025 Time: 10:27:47 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16349 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 10:27:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:27:58 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:28:00 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:28:01 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:28:03 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:28:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:28:22 Integrated Voltage Measurement... 10:28:31 Voltage Offset Correction: v_off_ini = -134.346 uV, v_off_fin = -143.386 uV 10:28:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.505 uVs 10:28:31 Integrated Voltage Measurement... 10:28:40 Voltage Offset Correction: v_off_ini = -136.816 uV, v_off_fin = -140.128 uV 10:28:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.786 uVs 10:28:40 Integrated Voltage Measurement... 10:28:49 Voltage Offset Correction: v_off_ini = -132.742 uV, v_off_fin = -128.771 uV 10:28:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.608 uVs 10:28:49 Integrated Voltage Measurement... 10:28:58 Voltage Offset Correction: v_off_ini = -133.870 uV, v_off_fin = -132.839 uV 10:28:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.361 uVs 10:28:58 Integrated Voltage Measurement... 10:29:07 Voltage Offset Correction: v_off_ini = -140.541 uV, v_off_fin = -137.106 uV 10:29:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.054 uVs 10:29:07 Integrated Voltage Measurement... 10:29:16 Voltage Offset Correction: v_off_ini = -135.260 uV, v_off_fin = -120.977 uV 10:29:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.521 uVs 10:29:20 I1X Average and RMS of Measurements VT = -123.972 +- 7.494 uVs I1X = 24.795 +- 1.499 uTm 10:29:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:29:27 Integrated Voltage Measurement... 10:29:36 Voltage Offset Correction: v_off_ini = -128.168 uV, v_off_fin = -141.398 uV 10:29:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.427 uVs 10:29:36 Integrated Voltage Measurement... 10:29:45 Voltage Offset Correction: v_off_ini = -124.625 uV, v_off_fin = -107.661 uV 10:29:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.949 uVs 10:29:45 Integrated Voltage Measurement... 10:29:54 Voltage Offset Correction: v_off_ini = -121.422 uV, v_off_fin = -141.136 uV 10:29:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.579 uVs 10:29:54 Integrated Voltage Measurement... 10:30:03 Voltage Offset Correction: v_off_ini = -123.513 uV, v_off_fin = -116.435 uV 10:30:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.370 uVs 10:30:03 Integrated Voltage Measurement... 10:30:12 Voltage Offset Correction: v_off_ini = -131.400 uV, v_off_fin = -135.449 uV 10:30:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.068 uVs 10:30:12 Integrated Voltage Measurement... 10:30:21 Voltage Offset Correction: v_off_ini = -120.348 uV, v_off_fin = -109.196 uV 10:30:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.554 uVs 10:30:25 I1Y Average and RMS of Measurements VT = -256.491 +- 7.235 uVs I1Y = -51.298 +- 1.447 uTm 10:30:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:30:33 Integrated Voltage Measurement... 10:30:42 Voltage Offset Correction: v_off_ini = -128.244 uV, v_off_fin = -121.709 uV 10:30:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.269 uVs 10:30:42 Integrated Voltage Measurement... 10:30:51 Voltage Offset Correction: v_off_ini = -111.644 uV, v_off_fin = -109.831 uV 10:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.928 uVs 10:30:51 Integrated Voltage Measurement... 10:31:00 Voltage Offset Correction: v_off_ini = -114.285 uV, v_off_fin = -105.878 uV 10:31:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.231 uVs 10:31:00 Integrated Voltage Measurement... 10:31:09 Voltage Offset Correction: v_off_ini = -101.914 uV, v_off_fin = -95.396 uV 10:31:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.625 uVs 10:31:09 Integrated Voltage Measurement... 10:31:18 Voltage Offset Correction: v_off_ini = -96.919 uV, v_off_fin = -111.619 uV 10:31:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.665 uVs 10:31:18 Integrated Voltage Measurement... 10:31:27 Voltage Offset Correction: v_off_ini = -113.931 uV, v_off_fin = -98.194 uV 10:31:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.343 uVs 10:31:30 I2X Average and RMS of Measurements VT = -139.177 +- 0.481 uVs I2X = 12.804 +- 0.044 uTm^2 10:31:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:31:37 Integrated Voltage Measurement... 10:31:46 Voltage Offset Correction: v_off_ini = -100.614 uV, v_off_fin = -98.010 uV 10:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.730 uVs 10:31:47 Integrated Voltage Measurement... 10:31:55 Voltage Offset Correction: v_off_ini = -88.854 uV, v_off_fin = -103.162 uV 10:31:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.219 uVs 10:31:56 Integrated Voltage Measurement... 10:32:05 Voltage Offset Correction: v_off_ini = -82.624 uV, v_off_fin = -84.965 uV 10:32:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.557 uVs 10:32:05 Integrated Voltage Measurement... 10:32:14 Voltage Offset Correction: v_off_ini = -79.382 uV, v_off_fin = -87.450 uV 10:32:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.881 uVs 10:32:14 Integrated Voltage Measurement... 10:32:23 Voltage Offset Correction: v_off_ini = -83.774 uV, v_off_fin = -85.957 uV 10:32:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.100 uVs 10:32:23 Integrated Voltage Measurement... 10:32:32 Voltage Offset Correction: v_off_ini = -83.951 uV, v_off_fin = -87.016 uV 10:32:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.271 uVs 10:32:34 I2Y Average and RMS of Measurements VT = -379.626 +- 5.205 uVs I2Y = -34.926 +- 0.479 uTm^2 10:32:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:32:49 Integrated Voltage Measurement... 10:32:58 Voltage Offset Correction: v_off_ini = -95.104 uV, v_off_fin = -100.038 uV 10:32:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -143.035 uVs 10:32:58 Integrated Voltage Measurement... 10:33:07 Voltage Offset Correction: v_off_ini = -87.247 uV, v_off_fin = -78.331 uV 10:33:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.868 uVs 10:33:07 Integrated Voltage Measurement... 10:33:16 Voltage Offset Correction: v_off_ini = -95.585 uV, v_off_fin = -99.512 uV 10:33:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.622 uVs 10:33:16 Integrated Voltage Measurement... 10:33:25 Voltage Offset Correction: v_off_ini = -86.403 uV, v_off_fin = -91.014 uV 10:33:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.556 uVs 10:33:25 Integrated Voltage Measurement... 10:33:34 Voltage Offset Correction: v_off_ini = -83.587 uV, v_off_fin = -93.554 uV 10:33:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.041 uVs 10:33:34 Integrated Voltage Measurement... 10:33:43 Voltage Offset Correction: v_off_ini = -83.605 uV, v_off_fin = -96.613 uV 10:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.241 uVs 10:33:47 I1X Average and RMS of Measurements VT = -147.561 +- 4.701 uVs I1X = 29.514 +- 0.939 uTm 10:33:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:33:54 Integrated Voltage Measurement... 10:34:03 Voltage Offset Correction: v_off_ini = -72.156 uV, v_off_fin = -84.487 uV 10:34:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -243.339 uVs 10:34:03 Integrated Voltage Measurement... 10:34:12 Voltage Offset Correction: v_off_ini = -72.570 uV, v_off_fin = -65.179 uV 10:34:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.387 uVs 10:34:12 Integrated Voltage Measurement... 10:34:21 Voltage Offset Correction: v_off_ini = -74.000 uV, v_off_fin = -84.628 uV 10:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.897 uVs 10:34:21 Integrated Voltage Measurement... 10:34:30 Voltage Offset Correction: v_off_ini = -78.119 uV, v_off_fin = -72.332 uV 10:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.168 uVs 10:34:30 Integrated Voltage Measurement... 10:34:39 Voltage Offset Correction: v_off_ini = -70.771 uV, v_off_fin = -77.945 uV 10:34:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.656 uVs 10:34:39 Integrated Voltage Measurement... 10:34:48 Voltage Offset Correction: v_off_ini = -69.129 uV, v_off_fin = -66.259 uV 10:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.369 uVs 10:34:53 I1Y Average and RMS of Measurements VT = -244.469 +- 2.144 uVs I1Y = -48.895 +- 0.430 uTm 10:34:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:35:00 Integrated Voltage Measurement... 10:35:09 Voltage Offset Correction: v_off_ini = -71.738 uV, v_off_fin = -75.257 uV 10:35:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.241 uVs 10:35:09 Integrated Voltage Measurement... 10:35:18 Voltage Offset Correction: v_off_ini = -50.638 uV, v_off_fin = -46.322 uV 10:35:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.158 uVs 10:35:18 Integrated Voltage Measurement... 10:35:27 Voltage Offset Correction: v_off_ini = -74.594 uV, v_off_fin = -87.206 uV 10:35:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.981 uVs 10:35:27 Integrated Voltage Measurement... 10:35:36 Voltage Offset Correction: v_off_ini = -67.141 uV, v_off_fin = -70.008 uV 10:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.471 uVs 10:35:36 Integrated Voltage Measurement... 10:35:45 Voltage Offset Correction: v_off_ini = -76.883 uV, v_off_fin = -89.094 uV 10:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.442 uVs 10:35:46 Integrated Voltage Measurement... 10:35:55 Voltage Offset Correction: v_off_ini = -91.900 uV, v_off_fin = -82.272 uV 10:35:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.191 uVs 10:35:57 I2X Average and RMS of Measurements VT = -145.247 +- 6.303 uVs I2X = 13.363 +- 0.580 uTm^2 10:36:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:36:05 Integrated Voltage Measurement... 10:36:14 Voltage Offset Correction: v_off_ini = -108.236 uV, v_off_fin = -114.270 uV 10:36:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.120 uVs 10:36:14 Integrated Voltage Measurement... 10:36:23 Voltage Offset Correction: v_off_ini = -99.410 uV, v_off_fin = -93.290 uV 10:36:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.601 uVs 10:36:23 Integrated Voltage Measurement... 10:36:32 Voltage Offset Correction: v_off_ini = -95.312 uV, v_off_fin = -88.585 uV 10:36:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -373.106 uVs 10:36:32 Integrated Voltage Measurement... 10:36:41 Voltage Offset Correction: v_off_ini = -91.961 uV, v_off_fin = -95.840 uV 10:36:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.504 uVs 10:36:41 Integrated Voltage Measurement... 10:36:50 Voltage Offset Correction: v_off_ini = -99.291 uV, v_off_fin = -97.701 uV 10:36:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.580 uVs 10:36:50 Integrated Voltage Measurement... 10:36:59 Voltage Offset Correction: v_off_ini = -96.678 uV, v_off_fin = -77.841 uV 10:36:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.870 uVs 10:37:01 I2Y Average and RMS of Measurements VT = -365.964 +- 4.058 uVs I2Y = -33.669 +- 0.373 uTm^2 10:37:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:37:16 Integrated Voltage Measurement... 10:37:25 Voltage Offset Correction: v_off_ini = -90.744 uV, v_off_fin = -95.654 uV 10:37:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.175 uVs 10:37:25 Integrated Voltage Measurement... 10:37:34 Voltage Offset Correction: v_off_ini = -83.668 uV, v_off_fin = -86.378 uV 10:37:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.152 uVs 10:37:34 Integrated Voltage Measurement... 10:37:43 Voltage Offset Correction: v_off_ini = -86.830 uV, v_off_fin = -84.262 uV 10:37:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -147.914 uVs 10:37:43 Integrated Voltage Measurement... 10:37:52 Voltage Offset Correction: v_off_ini = -67.272 uV, v_off_fin = -57.582 uV 10:37:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.006 uVs 10:37:52 Integrated Voltage Measurement... 10:38:01 Voltage Offset Correction: v_off_ini = -64.483 uV, v_off_fin = -68.663 uV 10:38:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -151.488 uVs 10:38:01 Integrated Voltage Measurement... 10:38:10 Voltage Offset Correction: v_off_ini = -71.004 uV, v_off_fin = -73.265 uV 10:38:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.093 uVs 10:38:15 I1X Average and RMS of Measurements VT = -148.305 +- 8.255 uVs I1X = 29.662 +- 1.651 uTm 10:38:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:38:21 Integrated Voltage Measurement... 10:38:30 Voltage Offset Correction: v_off_ini = -66.219 uV, v_off_fin = -84.291 uV 10:38:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -256.741 uVs 10:38:30 Integrated Voltage Measurement... 10:38:39 Voltage Offset Correction: v_off_ini = -84.908 uV, v_off_fin = -68.538 uV 10:38:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.519 uVs 10:38:39 Integrated Voltage Measurement... 10:38:48 Voltage Offset Correction: v_off_ini = -70.938 uV, v_off_fin = -82.203 uV 10:38:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.424 uVs 10:38:48 Integrated Voltage Measurement... 10:38:57 Voltage Offset Correction: v_off_ini = -77.731 uV, v_off_fin = -70.026 uV 10:38:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.552 uVs 10:38:58 Integrated Voltage Measurement... 10:39:06 Voltage Offset Correction: v_off_ini = -93.419 uV, v_off_fin = -96.694 uV 10:39:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.174 uVs 10:39:07 Integrated Voltage Measurement... 10:39:15 Voltage Offset Correction: v_off_ini = -82.838 uV, v_off_fin = -70.602 uV 10:39:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.115 uVs 10:39:20 I1Y Average and RMS of Measurements VT = -246.088 +- 5.358 uVs I1Y = -49.218 +- 1.073 uTm 10:39:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:39:27 Integrated Voltage Measurement... 10:39:36 Voltage Offset Correction: v_off_ini = -84.564 uV, v_off_fin = -76.637 uV 10:39:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -157.023 uVs 10:39:37 Integrated Voltage Measurement... 10:39:45 Voltage Offset Correction: v_off_ini = -60.947 uV, v_off_fin = -52.209 uV 10:39:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 184.637 uVs 10:39:46 Integrated Voltage Measurement... 10:39:55 Voltage Offset Correction: v_off_ini = -79.382 uV, v_off_fin = -95.174 uV 10:39:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.503 uVs 10:39:55 Integrated Voltage Measurement... 10:40:04 Voltage Offset Correction: v_off_ini = -81.925 uV, v_off_fin = -81.743 uV 10:40:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 174.305 uVs 10:40:04 Integrated Voltage Measurement... 10:40:13 Voltage Offset Correction: v_off_ini = -71.598 uV, v_off_fin = -82.351 uV 10:40:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.886 uVs 10:40:13 Integrated Voltage Measurement... 10:40:22 Voltage Offset Correction: v_off_ini = -80.455 uV, v_off_fin = -81.614 uV 10:40:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.003 uVs 10:40:24 I2X Average and RMS of Measurements VT = -169.393 +- 3.210 uVs I2X = 15.584 +- 0.295 uTm^2 10:40:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:40:32 Integrated Voltage Measurement... 10:40:41 Voltage Offset Correction: v_off_ini = -82.199 uV, v_off_fin = -80.038 uV 10:40:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.470 uVs 10:40:41 Integrated Voltage Measurement... 10:40:50 Voltage Offset Correction: v_off_ini = -76.065 uV, v_off_fin = -71.834 uV 10:40:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 366.665 uVs 10:40:50 Integrated Voltage Measurement... 10:40:59 Voltage Offset Correction: v_off_ini = -82.074 uV, v_off_fin = -72.569 uV 10:40:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.869 uVs 10:40:59 Integrated Voltage Measurement... 10:41:08 Voltage Offset Correction: v_off_ini = -89.240 uV, v_off_fin = -85.163 uV 10:41:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.292 uVs 10:41:08 Integrated Voltage Measurement... 10:41:17 Voltage Offset Correction: v_off_ini = -80.285 uV, v_off_fin = -75.479 uV 10:41:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.722 uVs 10:41:17 Integrated Voltage Measurement... 10:41:26 Voltage Offset Correction: v_off_ini = -79.976 uV, v_off_fin = -81.417 uV 10:41:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.051 uVs 10:41:29 I2Y Average and RMS of Measurements VT = -363.178 +- 3.972 uVs I2Y = -33.412 +- 0.365 uTm^2 10:41:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:41:44 Integrated Voltage Measurement... 10:41:52 Voltage Offset Correction: v_off_ini = -68.395 uV, v_off_fin = -73.816 uV 10:41:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -167.575 uVs 10:41:53 Integrated Voltage Measurement... 10:42:01 Voltage Offset Correction: v_off_ini = -78.879 uV, v_off_fin = -63.885 uV 10:42:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.501 uVs 10:42:02 Integrated Voltage Measurement... 10:42:10 Voltage Offset Correction: v_off_ini = -72.175 uV, v_off_fin = -73.323 uV 10:42:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.509 uVs 10:42:11 Integrated Voltage Measurement... 10:42:19 Voltage Offset Correction: v_off_ini = -57.841 uV, v_off_fin = -45.400 uV 10:42:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.096 uVs 10:42:20 Integrated Voltage Measurement... 10:42:29 Voltage Offset Correction: v_off_ini = -54.015 uV, v_off_fin = -55.448 uV 10:42:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.828 uVs 10:42:29 Integrated Voltage Measurement... 10:42:38 Voltage Offset Correction: v_off_ini = -49.636 uV, v_off_fin = -46.081 uV 10:42:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.229 uVs 10:42:42 I1X Average and RMS of Measurements VT = -161.290 +- 9.885 uVs I1X = 32.259 +- 1.979 uTm 10:42:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:42:48 Integrated Voltage Measurement... 10:42:57 Voltage Offset Correction: v_off_ini = -51.225 uV, v_off_fin = -61.833 uV 10:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.420 uVs 10:42:57 Integrated Voltage Measurement... 10:43:06 Voltage Offset Correction: v_off_ini = -60.308 uV, v_off_fin = -43.421 uV 10:43:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.304 uVs 10:43:06 Integrated Voltage Measurement... 10:43:15 Voltage Offset Correction: v_off_ini = -50.832 uV, v_off_fin = -65.815 uV 10:43:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.231 uVs 10:43:15 Integrated Voltage Measurement... 10:43:24 Voltage Offset Correction: v_off_ini = -50.920 uV, v_off_fin = -45.987 uV 10:43:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.640 uVs 10:43:24 Integrated Voltage Measurement... 10:43:33 Voltage Offset Correction: v_off_ini = -58.051 uV, v_off_fin = -72.001 uV 10:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.959 uVs 10:43:33 Integrated Voltage Measurement... 10:43:42 Voltage Offset Correction: v_off_ini = -56.441 uV, v_off_fin = -36.193 uV 10:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.482 uVs 10:43:47 I1Y Average and RMS of Measurements VT = -235.173 +- 9.095 uVs I1Y = -47.035 +- 1.819 uTm 10:43:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:43:54 Integrated Voltage Measurement... 10:44:03 Voltage Offset Correction: v_off_ini = -32.492 uV, v_off_fin = -52.962 uV 10:44:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -182.311 uVs 10:44:03 Integrated Voltage Measurement... 10:44:12 Voltage Offset Correction: v_off_ini = -48.365 uV, v_off_fin = -38.910 uV 10:44:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 181.194 uVs 10:44:12 Integrated Voltage Measurement... 10:44:21 Voltage Offset Correction: v_off_ini = -43.820 uV, v_off_fin = -51.382 uV 10:44:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.646 uVs 10:44:21 Integrated Voltage Measurement... 10:44:30 Voltage Offset Correction: v_off_ini = -34.052 uV, v_off_fin = -38.737 uV 10:44:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 178.175 uVs 10:44:30 Integrated Voltage Measurement... 10:44:39 Voltage Offset Correction: v_off_ini = -38.280 uV, v_off_fin = -36.158 uV 10:44:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.064 uVs 10:44:39 Integrated Voltage Measurement... 10:44:48 Voltage Offset Correction: v_off_ini = -41.721 uV, v_off_fin = -12.718 uV 10:44:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 182.792 uVs 10:44:51 I2X Average and RMS of Measurements VT = -176.697 +- 3.720 uVs I2X = 16.256 +- 0.342 uTm^2 10:44:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:44:58 Integrated Voltage Measurement... 10:45:07 Voltage Offset Correction: v_off_ini = -41.842 uV, v_off_fin = -43.175 uV 10:45:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.687 uVs 10:45:07 Integrated Voltage Measurement... 10:45:16 Voltage Offset Correction: v_off_ini = -35.842 uV, v_off_fin = -48.131 uV 10:45:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.220 uVs 10:45:16 Integrated Voltage Measurement... 10:45:25 Voltage Offset Correction: v_off_ini = -51.533 uV, v_off_fin = -52.251 uV 10:45:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.144 uVs 10:45:25 Integrated Voltage Measurement... 10:45:34 Voltage Offset Correction: v_off_ini = -52.026 uV, v_off_fin = -37.244 uV 10:45:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.040 uVs 10:45:34 Integrated Voltage Measurement... 10:45:43 Voltage Offset Correction: v_off_ini = -45.998 uV, v_off_fin = -55.588 uV 10:45:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.213 uVs 10:45:43 Integrated Voltage Measurement... 10:45:52 Voltage Offset Correction: v_off_ini = -55.127 uV, v_off_fin = -58.648 uV 10:45:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.072 uVs 10:45:55 I2Y Average and RMS of Measurements VT = -355.562 +- 3.592 uVs I2Y = -32.712 +- 0.330 uTm^2 10:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:46:10 Integrated Voltage Measurement... 10:46:19 Voltage Offset Correction: v_off_ini = -64.068 uV, v_off_fin = -60.561 uV 10:46:19 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -156.171 uVs 10:46:19 Integrated Voltage Measurement... 10:46:28 Voltage Offset Correction: v_off_ini = -49.374 uV, v_off_fin = -47.836 uV 10:46:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 158.231 uVs 10:46:28 Integrated Voltage Measurement... 10:46:37 Voltage Offset Correction: v_off_ini = -50.387 uV, v_off_fin = -58.366 uV 10:46:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.748 uVs 10:46:37 Integrated Voltage Measurement... 10:46:46 Voltage Offset Correction: v_off_ini = -50.735 uV, v_off_fin = -49.339 uV 10:46:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 166.476 uVs 10:46:46 Integrated Voltage Measurement... 10:46:55 Voltage Offset Correction: v_off_ini = -49.131 uV, v_off_fin = -46.367 uV 10:46:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -188.068 uVs 10:46:55 Integrated Voltage Measurement... 10:47:04 Voltage Offset Correction: v_off_ini = -51.723 uV, v_off_fin = -46.946 uV 10:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.918 uVs 10:47:08 I1X Average and RMS of Measurements VT = -166.269 +- 6.657 uVs I1X = 33.258 +- 1.328 uTm 10:47:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:47:15 Integrated Voltage Measurement... 10:47:24 Voltage Offset Correction: v_off_ini = -59.715 uV, v_off_fin = -61.011 uV 10:47:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -207.548 uVs 10:47:24 Integrated Voltage Measurement... 10:47:33 Voltage Offset Correction: v_off_ini = -59.619 uV, v_off_fin = -37.045 uV 10:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.553 uVs 10:47:33 Integrated Voltage Measurement... 10:47:42 Voltage Offset Correction: v_off_ini = -64.786 uV, v_off_fin = -63.510 uV 10:47:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.234 uVs 10:47:42 Integrated Voltage Measurement... 10:47:51 Voltage Offset Correction: v_off_ini = -55.009 uV, v_off_fin = -41.679 uV 10:47:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.256 uVs 10:47:51 Integrated Voltage Measurement... 10:48:00 Voltage Offset Correction: v_off_ini = -60.947 uV, v_off_fin = -58.360 uV 10:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.111 uVs 10:48:00 Integrated Voltage Measurement... 10:48:09 Voltage Offset Correction: v_off_ini = -47.919 uV, v_off_fin = -28.066 uV 10:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 244.793 uVs 10:48:13 I1Y Average and RMS of Measurements VT = -227.916 +- 5.714 uVs I1Y = -45.584 +- 1.139 uTm 10:48:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:48:21 Integrated Voltage Measurement... 10:48:30 Voltage Offset Correction: v_off_ini = -30.646 uV, v_off_fin = -41.360 uV 10:48:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -188.295 uVs 10:48:30 Integrated Voltage Measurement... 10:48:39 Voltage Offset Correction: v_off_ini = -29.636 uV, v_off_fin = -24.445 uV 10:48:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 181.254 uVs 10:48:39 Integrated Voltage Measurement... 10:48:48 Voltage Offset Correction: v_off_ini = -35.427 uV, v_off_fin = -47.029 uV 10:48:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.980 uVs 10:48:48 Integrated Voltage Measurement... 10:48:57 Voltage Offset Correction: v_off_ini = -50.011 uV, v_off_fin = -30.868 uV 10:48:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 197.105 uVs 10:48:57 Integrated Voltage Measurement... 10:49:06 Voltage Offset Correction: v_off_ini = -33.161 uV, v_off_fin = -44.637 uV 10:49:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.899 uVs 10:49:06 Integrated Voltage Measurement... 10:49:15 Voltage Offset Correction: v_off_ini = -29.121 uV, v_off_fin = -26.310 uV 10:49:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.515 uVs 10:49:17 I2X Average and RMS of Measurements VT = -177.008 +- 11.174 uVs I2X = 16.284 +- 1.028 uTm^2 10:49:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:49:25 Integrated Voltage Measurement... 10:49:34 Voltage Offset Correction: v_off_ini = -24.722 uV, v_off_fin = -32.165 uV 10:49:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.790 uVs 10:49:34 Integrated Voltage Measurement... 10:49:43 Voltage Offset Correction: v_off_ini = -37.606 uV, v_off_fin = -35.936 uV 10:49:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.122 uVs 10:49:43 Integrated Voltage Measurement... 10:49:52 Voltage Offset Correction: v_off_ini = -21.873 uV, v_off_fin = -24.586 uV 10:49:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.687 uVs 10:49:52 Integrated Voltage Measurement... 10:50:01 Voltage Offset Correction: v_off_ini = -17.493 uV, v_off_fin = -9.667 uV 10:50:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.100 uVs 10:50:01 Integrated Voltage Measurement... 10:50:10 Voltage Offset Correction: v_off_ini = -11.389 uV, v_off_fin = -13.977 uV 10:50:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.725 uVs 10:50:10 Integrated Voltage Measurement... 10:50:19 Voltage Offset Correction: v_off_ini = -31.787 uV, v_off_fin = -36.356 uV 10:50:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.434 uVs 10:50:21 I2Y Average and RMS of Measurements VT = -346.810 +- 2.033 uVs I2Y = -31.906 +- 0.187 uTm^2 10:50:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:36 Integrated Voltage Measurement... 10:50:45 Voltage Offset Correction: v_off_ini = -8.153 uV, v_off_fin = -17.895 uV 10:50:45 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -170.371 uVs 10:50:45 Integrated Voltage Measurement... 10:50:54 Voltage Offset Correction: v_off_ini = -15.339 uV, v_off_fin = -16.286 uV 10:50:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 161.861 uVs 10:50:54 Integrated Voltage Measurement... 10:51:03 Voltage Offset Correction: v_off_ini = -16.177 uV, v_off_fin = -19.970 uV 10:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.774 uVs 10:51:03 Integrated Voltage Measurement... 10:51:12 Voltage Offset Correction: v_off_ini = -24.663 uV, v_off_fin = -18.272 uV 10:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.315 uVs 10:51:12 Integrated Voltage Measurement... 10:51:21 Voltage Offset Correction: v_off_ini = -20.969 uV, v_off_fin = -28.260 uV 10:51:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.387 uVs 10:51:21 Integrated Voltage Measurement... 10:51:30 Voltage Offset Correction: v_off_ini = -17.008 uV, v_off_fin = -7.178 uV 10:51:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.464 uVs 10:51:35 I1X Average and RMS of Measurements VT = -169.195 +- 3.470 uVs I1X = 33.842 +- 0.691 uTm 10:51:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:41 Integrated Voltage Measurement... 10:51:50 Voltage Offset Correction: v_off_ini = -18.789 uV, v_off_fin = -30.149 uV 10:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.519 uVs 10:51:50 Integrated Voltage Measurement... 10:51:59 Voltage Offset Correction: v_off_ini = -15.194 uV, v_off_fin = 12.717 uV 10:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 246.314 uVs 10:51:59 Integrated Voltage Measurement... 10:52:08 Voltage Offset Correction: v_off_ini = 3.343 uV, v_off_fin = -17.627 uV 10:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.652 uVs 10:52:08 Integrated Voltage Measurement... 10:52:17 Voltage Offset Correction: v_off_ini = -1.827 uV, v_off_fin = 23.512 uV 10:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.313 uVs 10:52:17 Integrated Voltage Measurement... 10:52:26 Voltage Offset Correction: v_off_ini = 9.968 uV, v_off_fin = -3.767 uV 10:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.773 uVs 10:52:26 Integrated Voltage Measurement... 10:52:35 Voltage Offset Correction: v_off_ini = 4.725 uV, v_off_fin = 28.544 uV 10:52:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.550 uVs 10:52:39 I1Y Average and RMS of Measurements VT = -229.353 +- 5.809 uVs I1Y = -45.868 +- 1.162 uTm 10:52:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:47 Integrated Voltage Measurement... 10:52:56 Voltage Offset Correction: v_off_ini = 12.069 uV, v_off_fin = 16.949 uV 10:52:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -188.362 uVs 10:52:56 Integrated Voltage Measurement... 10:53:05 Voltage Offset Correction: v_off_ini = 35.715 uV, v_off_fin = 39.255 uV 10:53:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 183.531 uVs 10:53:05 Integrated Voltage Measurement... 10:53:14 Voltage Offset Correction: v_off_ini = 32.654 uV, v_off_fin = 16.637 uV 10:53:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -183.555 uVs 10:53:14 Integrated Voltage Measurement... 10:53:23 Voltage Offset Correction: v_off_ini = 26.752 uV, v_off_fin = 27.619 uV 10:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 172.808 uVs 10:53:23 Integrated Voltage Measurement... 10:53:32 Voltage Offset Correction: v_off_ini = 17.590 uV, v_off_fin = 15.408 uV 10:53:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -175.948 uVs 10:53:32 Integrated Voltage Measurement... 10:53:41 Voltage Offset Correction: v_off_ini = 25.190 uV, v_off_fin = 21.225 uV 10:53:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.417 uVs 10:53:44 I2X Average and RMS of Measurements VT = -180.770 +- 3.660 uVs I2X = 16.631 +- 0.337 uTm^2 10:53:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:51 Integrated Voltage Measurement... 10:54:00 Voltage Offset Correction: v_off_ini = 30.812 uV, v_off_fin = 20.060 uV 10:54:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.097 uVs 10:54:00 Integrated Voltage Measurement... 10:54:09 Voltage Offset Correction: v_off_ini = 23.580 uV, v_off_fin = 23.383 uV 10:54:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.783 uVs 10:54:09 Integrated Voltage Measurement... 10:54:18 Voltage Offset Correction: v_off_ini = 15.825 uV, v_off_fin = 14.826 uV 10:54:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.570 uVs 10:54:18 Integrated Voltage Measurement... 10:54:27 Voltage Offset Correction: v_off_ini = 7.930 uV, v_off_fin = 33.651 uV 10:54:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.458 uVs 10:54:27 Integrated Voltage Measurement... 10:54:36 Voltage Offset Correction: v_off_ini = 28.664 uV, v_off_fin = 30.803 uV 10:54:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.339 uVs 10:54:36 Integrated Voltage Measurement... 10:54:45 Voltage Offset Correction: v_off_ini = 36.524 uV, v_off_fin = 41.549 uV 10:54:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 352.957 uVs 10:54:48 I2Y Average and RMS of Measurements VT = -344.201 +- 1.901 uVs I2Y = -31.667 +- 0.176 uTm^2 10:54:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:55:03 Integrated Voltage Measurement... 10:55:12 Voltage Offset Correction: v_off_ini = 51.043 uV, v_off_fin = 15.859 uV 10:55:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -209.781 uVs 10:55:12 Integrated Voltage Measurement... 10:55:21 Voltage Offset Correction: v_off_ini = 58.741 uV, v_off_fin = 43.345 uV 10:55:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.878 uVs 10:55:21 Integrated Voltage Measurement... 10:55:30 Voltage Offset Correction: v_off_ini = 33.915 uV, v_off_fin = 30.148 uV 10:55:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -163.242 uVs 10:55:30 Integrated Voltage Measurement... 10:55:39 Voltage Offset Correction: v_off_ini = 34.908 uV, v_off_fin = 25.307 uV 10:55:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.978 uVs 10:55:39 Integrated Voltage Measurement... 10:55:48 Voltage Offset Correction: v_off_ini = 20.365 uV, v_off_fin = 23.795 uV 10:55:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -190.871 uVs 10:55:48 Integrated Voltage Measurement... 10:55:57 Voltage Offset Correction: v_off_ini = 26.472 uV, v_off_fin = 38.605 uV 10:55:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.359 uVs 10:56:01 I1X Average and RMS of Measurements VT = -182.685 +- 7.181 uVs I1X = 36.537 +- 1.436 uTm 10:56:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:08 Integrated Voltage Measurement... 10:56:17 Voltage Offset Correction: v_off_ini = 26.037 uV, v_off_fin = 24.302 uV 10:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.174 uVs 10:56:17 Integrated Voltage Measurement... 10:56:26 Voltage Offset Correction: v_off_ini = 30.605 uV, v_off_fin = 26.753 uV 10:56:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.407 uVs 10:56:26 Integrated Voltage Measurement... 10:56:35 Voltage Offset Correction: v_off_ini = 20.739 uV, v_off_fin = 24.889 uV 10:56:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.340 uVs 10:56:35 Integrated Voltage Measurement... 10:56:44 Voltage Offset Correction: v_off_ini = 38.885 uV, v_off_fin = 54.788 uV 10:56:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.571 uVs 10:56:44 Integrated Voltage Measurement... 10:56:53 Voltage Offset Correction: v_off_ini = 45.596 uV, v_off_fin = 36.582 uV 10:56:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.306 uVs 10:56:53 Integrated Voltage Measurement... 10:57:02 Voltage Offset Correction: v_off_ini = 32.045 uV, v_off_fin = 52.917 uV 10:57:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 224.134 uVs 10:57:06 I1Y Average and RMS of Measurements VT = -226.155 +- 2.589 uVs I1Y = -45.229 +- 0.519 uTm 10:57:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:57:14 Integrated Voltage Measurement... 10:57:22 Voltage Offset Correction: v_off_ini = 40.663 uV, v_off_fin = 23.641 uV 10:57:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -188.886 uVs 10:57:23 Integrated Voltage Measurement... 10:57:32 Voltage Offset Correction: v_off_ini = 41.071 uV, v_off_fin = 48.837 uV 10:57:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 189.526 uVs 10:57:32 Integrated Voltage Measurement... 10:57:41 Voltage Offset Correction: v_off_ini = 32.576 uV, v_off_fin = 29.428 uV 10:57:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -186.367 uVs 10:57:41 Integrated Voltage Measurement... 10:57:50 Voltage Offset Correction: v_off_ini = 52.285 uV, v_off_fin = 62.792 uV 10:57:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 191.861 uVs 10:57:50 Integrated Voltage Measurement... 10:57:59 Voltage Offset Correction: v_off_ini = 66.749 uV, v_off_fin = 53.034 uV 10:57:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -206.054 uVs 10:57:59 Integrated Voltage Measurement... 10:58:08 Voltage Offset Correction: v_off_ini = 61.900 uV, v_off_fin = 76.599 uV 10:58:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.594 uVs 10:58:10 I2X Average and RMS of Measurements VT = -191.715 +- 3.613 uVs I2X = 17.638 +- 0.332 uTm^2 10:58:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:58:18 Integrated Voltage Measurement... 10:58:27 Voltage Offset Correction: v_off_ini = 55.088 uV, v_off_fin = 60.782 uV 10:58:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.352 uVs 10:58:27 Integrated Voltage Measurement... 10:58:36 Voltage Offset Correction: v_off_ini = 70.164 uV, v_off_fin = 57.235 uV 10:58:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.513 uVs 10:58:36 Integrated Voltage Measurement... 10:58:45 Voltage Offset Correction: v_off_ini = 64.949 uV, v_off_fin = 55.161 uV 10:58:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.099 uVs 10:58:45 Integrated Voltage Measurement... 10:58:54 Voltage Offset Correction: v_off_ini = 71.231 uV, v_off_fin = 59.735 uV 10:58:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.543 uVs 10:58:54 Integrated Voltage Measurement... 10:59:03 Voltage Offset Correction: v_off_ini = 63.821 uV, v_off_fin = 57.362 uV 10:59:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.600 uVs 10:59:03 Integrated Voltage Measurement... 10:59:12 Voltage Offset Correction: v_off_ini = 63.114 uV, v_off_fin = 57.604 uV 10:59:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.443 uVs 10:59:14 I2Y Average and RMS of Measurements VT = -329.258 +- 5.469 uVs I2Y = -30.292 +- 0.503 uTm^2 10:59:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:59:29 Integrated Voltage Measurement... 10:59:38 Voltage Offset Correction: v_off_ini = 74.470 uV, v_off_fin = 50.666 uV 10:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.435 uVs 10:59:38 Integrated Voltage Measurement... 10:59:47 Voltage Offset Correction: v_off_ini = 55.197 uV, v_off_fin = 61.052 uV 10:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 182.816 uVs 10:59:47 Integrated Voltage Measurement... 10:59:56 Voltage Offset Correction: v_off_ini = 54.506 uV, v_off_fin = 48.651 uV 10:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.312 uVs 10:59:56 Integrated Voltage Measurement... 11:00:05 Voltage Offset Correction: v_off_ini = 51.919 uV, v_off_fin = 52.318 uV 11:00:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.294 uVs 11:00:05 Integrated Voltage Measurement... 11:00:14 Voltage Offset Correction: v_off_ini = 37.976 uV, v_off_fin = 56.826 uV 11:00:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.188 uVs 11:00:14 Integrated Voltage Measurement... 11:00:23 Voltage Offset Correction: v_off_ini = 49.783 uV, v_off_fin = 53.879 uV 11:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 184.225 uVs 11:00:28 I1X Average and RMS of Measurements VT = -180.378 +- 4.067 uVs I1X = 36.076 +- 0.813 uTm 11:00:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:00:34 Integrated Voltage Measurement... 11:00:43 Voltage Offset Correction: v_off_ini = 69.541 uV, v_off_fin = 44.335 uV 11:00:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.775 uVs 11:00:43 Integrated Voltage Measurement... 11:00:52 Voltage Offset Correction: v_off_ini = 62.213 uV, v_off_fin = 68.490 uV 11:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.352 uVs 11:00:52 Integrated Voltage Measurement... 11:01:01 Voltage Offset Correction: v_off_ini = 65.300 uV, v_off_fin = 50.116 uV 11:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.797 uVs 11:01:01 Integrated Voltage Measurement... 11:01:10 Voltage Offset Correction: v_off_ini = 61.572 uV, v_off_fin = 64.768 uV 11:01:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 236.076 uVs 11:01:10 Integrated Voltage Measurement... 11:01:19 Voltage Offset Correction: v_off_ini = 60.048 uV, v_off_fin = 49.321 uV 11:01:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.981 uVs 11:01:19 Integrated Voltage Measurement... 11:01:28 Voltage Offset Correction: v_off_ini = 74.317 uV, v_off_fin = 88.536 uV 11:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.200 uVs 11:01:33 I1Y Average and RMS of Measurements VT = -230.363 +- 6.677 uVs I1Y = -46.070 +- 1.335 uTm 11:01:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:40 Integrated Voltage Measurement... 11:01:49 Voltage Offset Correction: v_off_ini = 52.768 uV, v_off_fin = 44.947 uV 11:01:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -201.597 uVs 11:01:49 Integrated Voltage Measurement... 11:01:58 Voltage Offset Correction: v_off_ini = 65.489 uV, v_off_fin = 61.710 uV 11:01:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 177.963 uVs 11:01:58 Integrated Voltage Measurement... 11:02:07 Voltage Offset Correction: v_off_ini = 60.814 uV, v_off_fin = 37.131 uV 11:02:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.869 uVs 11:02:07 Integrated Voltage Measurement... 11:02:16 Voltage Offset Correction: v_off_ini = 62.176 uV, v_off_fin = 68.999 uV 11:02:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 186.343 uVs 11:02:16 Integrated Voltage Measurement... 11:02:25 Voltage Offset Correction: v_off_ini = 59.792 uV, v_off_fin = 64.094 uV 11:02:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -191.321 uVs 11:02:26 Integrated Voltage Measurement... 11:02:34 Voltage Offset Correction: v_off_ini = 69.607 uV, v_off_fin = 65.140 uV 11:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.481 uVs 11:02:37 I2X Average and RMS of Measurements VT = -189.762 +- 5.836 uVs I2X = 17.458 +- 0.537 uTm^2 11:02:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:45 Integrated Voltage Measurement... 11:02:54 Voltage Offset Correction: v_off_ini = 70.756 uV, v_off_fin = 76.201 uV 11:02:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.039 uVs 11:02:54 Integrated Voltage Measurement... 11:03:03 Voltage Offset Correction: v_off_ini = 59.265 uV, v_off_fin = 57.579 uV 11:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.742 uVs 11:03:03 Integrated Voltage Measurement... 11:03:12 Voltage Offset Correction: v_off_ini = 58.573 uV, v_off_fin = 68.340 uV 11:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.610 uVs 11:03:12 Integrated Voltage Measurement... 11:03:21 Voltage Offset Correction: v_off_ini = 65.293 uV, v_off_fin = 65.868 uV 11:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.749 uVs 11:03:21 Integrated Voltage Measurement... 11:03:30 Voltage Offset Correction: v_off_ini = 79.131 uV, v_off_fin = 61.164 uV 11:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.293 uVs 11:03:30 Integrated Voltage Measurement... 11:03:39 Voltage Offset Correction: v_off_ini = 71.890 uV, v_off_fin = 67.326 uV 11:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.277 uVs 11:03:41 I2Y Average and RMS of Measurements VT = -331.285 +- 9.685 uVs I2Y = -30.478 +- 0.891 uTm^2 11:03:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:03:56 Integrated Voltage Measurement... 11:04:05 Voltage Offset Correction: v_off_ini = 84.488 uV, v_off_fin = 83.681 uV 11:04:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -201.037 uVs 11:04:05 Integrated Voltage Measurement... 11:04:14 Voltage Offset Correction: v_off_ini = 78.759 uV, v_off_fin = 86.021 uV 11:04:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.528 uVs 11:04:14 Integrated Voltage Measurement... 11:04:23 Voltage Offset Correction: v_off_ini = 59.814 uV, v_off_fin = 63.538 uV 11:04:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.744 uVs 11:04:23 Integrated Voltage Measurement... 11:04:32 Voltage Offset Correction: v_off_ini = 90.409 uV, v_off_fin = 81.902 uV 11:04:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.216 uVs 11:04:32 Integrated Voltage Measurement... 11:04:41 Voltage Offset Correction: v_off_ini = 72.050 uV, v_off_fin = 76.797 uV 11:04:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -179.342 uVs 11:04:41 Integrated Voltage Measurement... 11:04:50 Voltage Offset Correction: v_off_ini = 87.644 uV, v_off_fin = 83.671 uV 11:04:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.245 uVs 11:04:54 I1X Average and RMS of Measurements VT = -183.019 +- 7.612 uVs I1X = 36.604 +- 1.523 uTm 11:04:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:01 Integrated Voltage Measurement... 11:05:10 Voltage Offset Correction: v_off_ini = 59.398 uV, v_off_fin = 73.293 uV 11:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.259 uVs 11:05:10 Integrated Voltage Measurement... 11:05:19 Voltage Offset Correction: v_off_ini = 80.662 uV, v_off_fin = 91.903 uV 11:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.958 uVs 11:05:19 Integrated Voltage Measurement... 11:05:28 Voltage Offset Correction: v_off_ini = 90.928 uV, v_off_fin = 69.549 uV 11:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.432 uVs 11:05:28 Integrated Voltage Measurement... 11:05:37 Voltage Offset Correction: v_off_ini = 71.257 uV, v_off_fin = 92.665 uV 11:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.475 uVs 11:05:37 Integrated Voltage Measurement... 11:05:46 Voltage Offset Correction: v_off_ini = 90.972 uV, v_off_fin = 80.213 uV 11:05:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.093 uVs 11:05:46 Integrated Voltage Measurement... 11:05:55 Voltage Offset Correction: v_off_ini = 96.037 uV, v_off_fin = 112.531 uV 11:05:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.466 uVs 11:05:59 I1Y Average and RMS of Measurements VT = -227.614 +- 4.169 uVs I1Y = -45.519 +- 0.834 uTm 11:06:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:07 Integrated Voltage Measurement... 11:06:16 Voltage Offset Correction: v_off_ini = 97.798 uV, v_off_fin = 89.926 uV 11:06:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -200.435 uVs 11:06:16 Integrated Voltage Measurement... 11:06:25 Voltage Offset Correction: v_off_ini = 102.081 uV, v_off_fin = 101.630 uV 11:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 197.235 uVs 11:06:25 Integrated Voltage Measurement... 11:06:34 Voltage Offset Correction: v_off_ini = 91.083 uV, v_off_fin = 70.235 uV 11:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -227.607 uVs 11:06:34 Integrated Voltage Measurement... 11:06:43 Voltage Offset Correction: v_off_ini = 82.926 uV, v_off_fin = 111.788 uV 11:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 194.982 uVs 11:06:43 Integrated Voltage Measurement... 11:06:52 Voltage Offset Correction: v_off_ini = 78.307 uV, v_off_fin = 72.711 uV 11:06:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -201.206 uVs 11:06:52 Integrated Voltage Measurement... 11:07:01 Voltage Offset Correction: v_off_ini = 86.309 uV, v_off_fin = 93.559 uV 11:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.288 uVs 11:07:04 I2X Average and RMS of Measurements VT = -204.459 +- 5.158 uVs I2X = 18.810 +- 0.475 uTm^2 11:07:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:07:11 Integrated Voltage Measurement... 11:07:20 Voltage Offset Correction: v_off_ini = 82.923 uV, v_off_fin = 86.679 uV 11:07:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -315.701 uVs 11:07:20 Integrated Voltage Measurement... 11:07:29 Voltage Offset Correction: v_off_ini = 89.063 uV, v_off_fin = 90.787 uV 11:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.851 uVs 11:07:29 Integrated Voltage Measurement... 11:07:38 Voltage Offset Correction: v_off_ini = 111.725 uV, v_off_fin = 104.775 uV 11:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.842 uVs 11:07:38 Integrated Voltage Measurement... 11:07:47 Voltage Offset Correction: v_off_ini = 109.575 uV, v_off_fin = 101.768 uV 11:07:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.678 uVs 11:07:48 Integrated Voltage Measurement... 11:07:57 Voltage Offset Correction: v_off_ini = 92.053 uV, v_off_fin = 91.999 uV 11:07:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.899 uVs 11:07:57 Integrated Voltage Measurement... 11:08:06 Voltage Offset Correction: v_off_ini = 96.394 uV, v_off_fin = 85.224 uV 11:08:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.192 uVs 11:08:08 I2Y Average and RMS of Measurements VT = -321.361 +- 10.731 uVs I2Y = -29.566 +- 0.987 uTm^2 11:08:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:23 Integrated Voltage Measurement... 11:08:32 Voltage Offset Correction: v_off_ini = 95.667 uV, v_off_fin = 91.390 uV 11:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -178.416 uVs 11:08:32 Integrated Voltage Measurement... 11:08:41 Voltage Offset Correction: v_off_ini = 103.862 uV, v_off_fin = 101.948 uV 11:08:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.782 uVs 11:08:41 Integrated Voltage Measurement... 11:08:50 Voltage Offset Correction: v_off_ini = 102.733 uV, v_off_fin = 94.325 uV 11:08:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -191.919 uVs 11:08:50 Integrated Voltage Measurement... 11:08:59 Voltage Offset Correction: v_off_ini = 101.210 uV, v_off_fin = 115.076 uV 11:08:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.714 uVs 11:08:59 Integrated Voltage Measurement... 11:09:08 Voltage Offset Correction: v_off_ini = 105.047 uV, v_off_fin = 104.799 uV 11:09:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.628 uVs 11:09:08 Integrated Voltage Measurement... 11:09:17 Voltage Offset Correction: v_off_ini = 101.245 uV, v_off_fin = 101.870 uV 11:09:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 195.058 uVs 11:09:21 I1X Average and RMS of Measurements VT = -181.419 +- 5.638 uVs I1X = 36.284 +- 1.128 uTm 11:09:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:28 Integrated Voltage Measurement... 11:09:37 Voltage Offset Correction: v_off_ini = 92.916 uV, v_off_fin = 100.113 uV 11:09:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.390 uVs 11:09:37 Integrated Voltage Measurement... 11:09:46 Voltage Offset Correction: v_off_ini = 122.522 uV, v_off_fin = 132.474 uV 11:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.174 uVs 11:09:46 Integrated Voltage Measurement... 11:09:55 Voltage Offset Correction: v_off_ini = 111.642 uV, v_off_fin = 98.179 uV 11:09:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.158 uVs 11:09:55 Integrated Voltage Measurement... 11:10:04 Voltage Offset Correction: v_off_ini = 121.012 uV, v_off_fin = 125.999 uV 11:10:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.187 uVs 11:10:04 Integrated Voltage Measurement... 11:10:13 Voltage Offset Correction: v_off_ini = 101.788 uV, v_off_fin = 87.798 uV 11:10:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.285 uVs 11:10:13 Integrated Voltage Measurement... 11:10:22 Voltage Offset Correction: v_off_ini = 109.460 uV, v_off_fin = 119.744 uV 11:10:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.736 uVs 11:10:26 I1Y Average and RMS of Measurements VT = -218.988 +- 3.409 uVs I1Y = -43.796 +- 0.680 uTm 11:10:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:34 Integrated Voltage Measurement... 11:10:43 Voltage Offset Correction: v_off_ini = 89.720 uV, v_off_fin = 87.854 uV 11:10:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -201.808 uVs 11:10:43 Integrated Voltage Measurement... 11:10:52 Voltage Offset Correction: v_off_ini = 101.578 uV, v_off_fin = 113.206 uV 11:10:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 198.872 uVs 11:10:52 Integrated Voltage Measurement... 11:11:01 Voltage Offset Correction: v_off_ini = 96.332 uV, v_off_fin = 94.782 uV 11:11:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.333 uVs 11:11:01 Integrated Voltage Measurement... 11:11:10 Voltage Offset Correction: v_off_ini = 112.457 uV, v_off_fin = 118.994 uV 11:11:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 214.914 uVs 11:11:10 Integrated Voltage Measurement... 11:11:19 Voltage Offset Correction: v_off_ini = 103.631 uV, v_off_fin = 93.267 uV 11:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -209.421 uVs 11:11:19 Integrated Voltage Measurement... 11:11:28 Voltage Offset Correction: v_off_ini = 101.975 uV, v_off_fin = 105.374 uV 11:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 199.681 uVs 11:11:31 I2X Average and RMS of Measurements VT = -201.005 +- 2.666 uVs I2X = 18.492 +- 0.245 uTm^2 11:11:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:38 Integrated Voltage Measurement... 11:11:47 Voltage Offset Correction: v_off_ini = 81.299 uV, v_off_fin = 106.364 uV 11:11:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -306.517 uVs 11:11:47 Integrated Voltage Measurement... 11:11:56 Voltage Offset Correction: v_off_ini = 111.978 uV, v_off_fin = 93.072 uV 11:11:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.383 uVs 11:11:56 Integrated Voltage Measurement... 11:12:05 Voltage Offset Correction: v_off_ini = 97.213 uV, v_off_fin = 92.065 uV 11:12:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.823 uVs 11:12:05 Integrated Voltage Measurement... 11:12:14 Voltage Offset Correction: v_off_ini = 87.891 uV, v_off_fin = 99.851 uV 11:12:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.371 uVs 11:12:15 Integrated Voltage Measurement... 11:12:24 Voltage Offset Correction: v_off_ini = 99.223 uV, v_off_fin = 105.100 uV 11:12:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.201 uVs 11:12:24 Integrated Voltage Measurement... 11:12:33 Voltage Offset Correction: v_off_ini = 107.945 uV, v_off_fin = 108.562 uV 11:12:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.529 uVs 11:12:35 I2Y Average and RMS of Measurements VT = -318.304 +- 8.441 uVs I2Y = -29.284 +- 0.776 uTm^2 11:12:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:50 Integrated Voltage Measurement... 11:12:59 Voltage Offset Correction: v_off_ini = 105.666 uV, v_off_fin = 104.004 uV 11:12:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -202.257 uVs 11:12:59 Integrated Voltage Measurement... 11:13:08 Voltage Offset Correction: v_off_ini = 98.703 uV, v_off_fin = 106.094 uV 11:13:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 197.354 uVs 11:13:08 Integrated Voltage Measurement... 11:13:17 Voltage Offset Correction: v_off_ini = 105.720 uV, v_off_fin = 90.028 uV 11:13:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.038 uVs 11:13:17 Integrated Voltage Measurement... 11:13:26 Voltage Offset Correction: v_off_ini = 103.015 uV, v_off_fin = 108.530 uV 11:13:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 199.510 uVs 11:13:26 Integrated Voltage Measurement... 11:13:35 Voltage Offset Correction: v_off_ini = 107.938 uV, v_off_fin = 97.055 uV 11:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.420 uVs 11:13:35 Integrated Voltage Measurement... 11:13:44 Voltage Offset Correction: v_off_ini = 111.157 uV, v_off_fin = 114.610 uV 11:13:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 175.432 uVs 11:13:48 I1X Average and RMS of Measurements VT = -190.169 +- 8.357 uVs I1X = 38.036 +- 1.672 uTm 11:13:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:55 Integrated Voltage Measurement... 11:14:04 Voltage Offset Correction: v_off_ini = 104.071 uV, v_off_fin = 90.536 uV 11:14:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.245 uVs 11:14:04 Integrated Voltage Measurement... 11:14:13 Voltage Offset Correction: v_off_ini = 98.607 uV, v_off_fin = 110.796 uV 11:14:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.127 uVs 11:14:13 Integrated Voltage Measurement... 11:14:22 Voltage Offset Correction: v_off_ini = 111.111 uV, v_off_fin = 101.408 uV 11:14:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.558 uVs 11:14:22 Integrated Voltage Measurement... 11:14:31 Voltage Offset Correction: v_off_ini = 110.762 uV, v_off_fin = 116.120 uV 11:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.464 uVs 11:14:31 Integrated Voltage Measurement... 11:14:40 Voltage Offset Correction: v_off_ini = 113.936 uV, v_off_fin = 108.170 uV 11:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.935 uVs 11:14:40 Integrated Voltage Measurement... 11:14:49 Voltage Offset Correction: v_off_ini = 114.193 uV, v_off_fin = 131.695 uV 11:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.780 uVs 11:14:53 I1Y Average and RMS of Measurements VT = -221.852 +- 7.820 uVs I1Y = -44.369 +- 1.563 uTm 11:14:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:01 Integrated Voltage Measurement... 11:15:10 Voltage Offset Correction: v_off_ini = 102.813 uV, v_off_fin = 100.402 uV 11:15:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -189.879 uVs 11:15:10 Integrated Voltage Measurement... 11:15:19 Voltage Offset Correction: v_off_ini = 121.427 uV, v_off_fin = 118.531 uV 11:15:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 204.785 uVs 11:15:19 Integrated Voltage Measurement... 11:15:28 Voltage Offset Correction: v_off_ini = 120.618 uV, v_off_fin = 110.014 uV 11:15:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -214.531 uVs 11:15:28 Integrated Voltage Measurement... 11:15:37 Voltage Offset Correction: v_off_ini = 118.536 uV, v_off_fin = 124.248 uV 11:15:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 223.152 uVs 11:15:37 Integrated Voltage Measurement... 11:15:46 Voltage Offset Correction: v_off_ini = 117.120 uV, v_off_fin = 119.196 uV 11:15:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -198.187 uVs 11:15:46 Integrated Voltage Measurement... 11:15:55 Voltage Offset Correction: v_off_ini = 124.904 uV, v_off_fin = 127.335 uV 11:15:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 221.984 uVs 11:15:58 I2X Average and RMS of Measurements VT = -208.753 +- 8.832 uVs I2X = 19.205 +- 0.813 uTm^2 11:16:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:16:05 Integrated Voltage Measurement... 11:16:14 Voltage Offset Correction: v_off_ini = 120.250 uV, v_off_fin = 115.648 uV 11:16:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.122 uVs 11:16:14 Integrated Voltage Measurement... 11:16:23 Voltage Offset Correction: v_off_ini = 117.762 uV, v_off_fin = 120.369 uV 11:16:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.276 uVs 11:16:23 Integrated Voltage Measurement... 11:16:32 Voltage Offset Correction: v_off_ini = 122.288 uV, v_off_fin = 117.339 uV 11:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.616 uVs 11:16:32 Integrated Voltage Measurement... 11:16:41 Voltage Offset Correction: v_off_ini = 117.903 uV, v_off_fin = 128.923 uV 11:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.111 uVs 11:16:42 Integrated Voltage Measurement... 11:16:50 Voltage Offset Correction: v_off_ini = 126.673 uV, v_off_fin = 118.628 uV 11:16:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.249 uVs 11:16:51 Integrated Voltage Measurement... 11:17:00 Voltage Offset Correction: v_off_ini = 121.696 uV, v_off_fin = 113.476 uV 11:17:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.478 uVs 11:17:02 I2Y Average and RMS of Measurements VT = -310.975 +- 12.249 uVs I2Y = -28.610 +- 1.127 uTm^2 11:17:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:18 Integrated Voltage Measurement... 11:17:27 Voltage Offset Correction: v_off_ini = 125.802 uV, v_off_fin = 119.950 uV 11:17:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -191.770 uVs 11:17:27 Integrated Voltage Measurement... 11:17:36 Voltage Offset Correction: v_off_ini = 131.947 uV, v_off_fin = 129.865 uV 11:17:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 184.362 uVs 11:17:36 Integrated Voltage Measurement... 11:17:45 Voltage Offset Correction: v_off_ini = 120.325 uV, v_off_fin = 115.316 uV 11:17:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -192.070 uVs 11:17:45 Integrated Voltage Measurement... 11:17:54 Voltage Offset Correction: v_off_ini = 125.434 uV, v_off_fin = 118.459 uV 11:17:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.487 uVs 11:17:54 Integrated Voltage Measurement... 11:18:03 Voltage Offset Correction: v_off_ini = 116.208 uV, v_off_fin = 108.926 uV 11:18:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -191.991 uVs 11:18:03 Integrated Voltage Measurement... 11:18:12 Voltage Offset Correction: v_off_ini = 118.577 uV, v_off_fin = 124.792 uV 11:18:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.843 uVs 11:18:16 I1X Average and RMS of Measurements VT = -188.087 +- 0.964 uVs I1X = 37.620 +- 0.193 uTm 11:18:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:23 Integrated Voltage Measurement... 11:18:32 Voltage Offset Correction: v_off_ini = 125.050 uV, v_off_fin = 125.173 uV 11:18:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.104 uVs 11:18:32 Integrated Voltage Measurement... 11:18:41 Voltage Offset Correction: v_off_ini = 151.401 uV, v_off_fin = 157.471 uV 11:18:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.501 uVs 11:18:41 Integrated Voltage Measurement... 11:18:50 Voltage Offset Correction: v_off_ini = 146.113 uV, v_off_fin = 134.271 uV 11:18:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.176 uVs 11:18:50 Integrated Voltage Measurement... 11:18:59 Voltage Offset Correction: v_off_ini = 137.555 uV, v_off_fin = 158.628 uV 11:18:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.448 uVs 11:18:59 Integrated Voltage Measurement... 11:19:08 Voltage Offset Correction: v_off_ini = 142.153 uV, v_off_fin = 125.938 uV 11:19:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.553 uVs 11:19:08 Integrated Voltage Measurement... 11:19:17 Voltage Offset Correction: v_off_ini = 144.526 uV, v_off_fin = 152.092 uV 11:19:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.004 uVs 11:19:21 I1Y Average and RMS of Measurements VT = -218.631 +- 7.122 uVs I1Y = -43.725 +- 1.422 uTm 11:19:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:29 Integrated Voltage Measurement... 11:19:38 Voltage Offset Correction: v_off_ini = 121.335 uV, v_off_fin = 119.752 uV 11:19:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -191.907 uVs 11:19:38 Integrated Voltage Measurement... 11:19:47 Voltage Offset Correction: v_off_ini = 128.083 uV, v_off_fin = 137.770 uV 11:19:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 193.616 uVs 11:19:47 Integrated Voltage Measurement... 11:19:56 Voltage Offset Correction: v_off_ini = 127.418 uV, v_off_fin = 119.853 uV 11:19:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -215.102 uVs 11:19:56 Integrated Voltage Measurement... 11:20:05 Voltage Offset Correction: v_off_ini = 126.927 uV, v_off_fin = 149.809 uV 11:20:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 210.772 uVs 11:20:05 Integrated Voltage Measurement... 11:20:14 Voltage Offset Correction: v_off_ini = 143.608 uV, v_off_fin = 129.999 uV 11:20:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -216.201 uVs 11:20:14 Integrated Voltage Measurement... 11:20:23 Voltage Offset Correction: v_off_ini = 134.860 uV, v_off_fin = 150.500 uV 11:20:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.627 uVs 11:20:26 I2X Average and RMS of Measurements VT = -205.538 +- 9.072 uVs I2X = 18.909 +- 0.835 uTm^2 11:20:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:33 Integrated Voltage Measurement... 11:20:42 Voltage Offset Correction: v_off_ini = 147.202 uV, v_off_fin = 129.935 uV 11:20:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -307.251 uVs 11:20:42 Integrated Voltage Measurement... 11:20:51 Voltage Offset Correction: v_off_ini = 129.017 uV, v_off_fin = 137.987 uV 11:20:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.734 uVs 11:20:51 Integrated Voltage Measurement... 11:21:00 Voltage Offset Correction: v_off_ini = 129.296 uV, v_off_fin = 118.942 uV 11:21:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.521 uVs 11:21:01 Integrated Voltage Measurement... 11:21:09 Voltage Offset Correction: v_off_ini = 125.942 uV, v_off_fin = 135.168 uV 11:21:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.551 uVs 11:21:10 Integrated Voltage Measurement... 11:21:19 Voltage Offset Correction: v_off_ini = 137.911 uV, v_off_fin = 127.024 uV 11:21:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.202 uVs 11:21:19 Integrated Voltage Measurement... 11:21:28 Voltage Offset Correction: v_off_ini = 133.512 uV, v_off_fin = 141.648 uV 11:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.465 uVs 11:21:30 I2Y Average and RMS of Measurements VT = -304.454 +- 6.648 uVs I2Y = -28.010 +- 0.612 uTm^2 11:21:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:46 Integrated Voltage Measurement... 11:21:55 Voltage Offset Correction: v_off_ini = 120.535 uV, v_off_fin = 119.345 uV 11:21:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -206.492 uVs 11:21:55 Integrated Voltage Measurement... 11:22:04 Voltage Offset Correction: v_off_ini = 122.866 uV, v_off_fin = 124.604 uV 11:22:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 190.865 uVs 11:22:04 Integrated Voltage Measurement... 11:22:13 Voltage Offset Correction: v_off_ini = 124.209 uV, v_off_fin = 120.294 uV 11:22:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.062 uVs 11:22:13 Integrated Voltage Measurement... 11:22:22 Voltage Offset Correction: v_off_ini = 124.369 uV, v_off_fin = 126.669 uV 11:22:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 191.095 uVs 11:22:22 Integrated Voltage Measurement... 11:22:31 Voltage Offset Correction: v_off_ini = 115.774 uV, v_off_fin = 119.953 uV 11:22:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -172.659 uVs 11:22:31 Integrated Voltage Measurement... 11:22:40 Voltage Offset Correction: v_off_ini = 117.137 uV, v_off_fin = 131.286 uV 11:22:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.216 uVs 11:22:44 I1X Average and RMS of Measurements VT = -191.565 +- 6.515 uVs I1X = 38.315 +- 1.305 uTm 11:22:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:51 Integrated Voltage Measurement... 11:23:00 Voltage Offset Correction: v_off_ini = 115.466 uV, v_off_fin = 117.285 uV 11:23:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -203.001 uVs 11:23:00 Integrated Voltage Measurement... 11:23:09 Voltage Offset Correction: v_off_ini = 114.502 uV, v_off_fin = 131.688 uV 11:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.081 uVs 11:23:09 Integrated Voltage Measurement... 11:23:18 Voltage Offset Correction: v_off_ini = 112.363 uV, v_off_fin = 104.504 uV 11:23:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.344 uVs 11:23:18 Integrated Voltage Measurement... 11:23:27 Voltage Offset Correction: v_off_ini = 110.636 uV, v_off_fin = 134.507 uV 11:23:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.192 uVs 11:23:27 Integrated Voltage Measurement... 11:23:36 Voltage Offset Correction: v_off_ini = 118.667 uV, v_off_fin = 118.057 uV 11:23:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.501 uVs 11:23:36 Integrated Voltage Measurement... 11:23:45 Voltage Offset Correction: v_off_ini = 124.869 uV, v_off_fin = 140.811 uV 11:23:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.927 uVs 11:23:49 I1Y Average and RMS of Measurements VT = -209.508 +- 0.508 uVs I1Y = -41.904 +- 0.100 uTm 11:23:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:57 Integrated Voltage Measurement... 11:24:06 Voltage Offset Correction: v_off_ini = 132.249 uV, v_off_fin = 129.864 uV 11:24:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -185.962 uVs 11:24:06 Integrated Voltage Measurement... 11:24:15 Voltage Offset Correction: v_off_ini = 143.005 uV, v_off_fin = 156.200 uV 11:24:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 210.553 uVs 11:24:15 Integrated Voltage Measurement... 11:24:24 Voltage Offset Correction: v_off_ini = 144.882 uV, v_off_fin = 130.437 uV 11:24:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -198.612 uVs 11:24:24 Integrated Voltage Measurement... 11:24:33 Voltage Offset Correction: v_off_ini = 143.066 uV, v_off_fin = 152.443 uV 11:24:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 217.663 uVs 11:24:33 Integrated Voltage Measurement... 11:24:42 Voltage Offset Correction: v_off_ini = 145.851 uV, v_off_fin = 132.684 uV 11:24:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -198.385 uVs 11:24:42 Integrated Voltage Measurement... 11:24:51 Voltage Offset Correction: v_off_ini = 153.111 uV, v_off_fin = 167.136 uV 11:24:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 214.767 uVs 11:24:54 I2X Average and RMS of Measurements VT = -204.324 +- 4.337 uVs I2X = 18.798 +- 0.399 uTm^2 11:24:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:02 Integrated Voltage Measurement... 11:25:11 Voltage Offset Correction: v_off_ini = 158.438 uV, v_off_fin = 157.442 uV 11:25:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.848 uVs 11:25:11 Integrated Voltage Measurement... 11:25:20 Voltage Offset Correction: v_off_ini = 159.594 uV, v_off_fin = 177.283 uV 11:25:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.106 uVs 11:25:20 Integrated Voltage Measurement... 11:25:29 Voltage Offset Correction: v_off_ini = 168.734 uV, v_off_fin = 158.259 uV 11:25:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.280 uVs 11:25:29 Integrated Voltage Measurement... 11:25:38 Voltage Offset Correction: v_off_ini = 160.025 uV, v_off_fin = 168.562 uV 11:25:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.745 uVs 11:25:38 Integrated Voltage Measurement... 11:25:47 Voltage Offset Correction: v_off_ini = 163.784 uV, v_off_fin = 166.091 uV 11:25:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.009 uVs 11:25:47 Integrated Voltage Measurement... 11:25:56 Voltage Offset Correction: v_off_ini = 170.866 uV, v_off_fin = 165.353 uV 11:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.176 uVs 11:25:58 I2Y Average and RMS of Measurements VT = -289.194 +- 5.307 uVs I2Y = -26.606 +- 0.488 uTm^2 11:26:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:16 Integrated Voltage Measurement... 11:26:25 Voltage Offset Correction: v_off_ini = 161.723 uV, v_off_fin = 170.212 uV 11:26:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -181.616 uVs 11:26:25 Integrated Voltage Measurement... 11:26:34 Voltage Offset Correction: v_off_ini = 177.074 uV, v_off_fin = 179.848 uV 11:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.003 uVs 11:26:35 Integrated Voltage Measurement... 11:26:43 Voltage Offset Correction: v_off_ini = 167.720 uV, v_off_fin = 161.147 uV 11:26:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -186.892 uVs 11:26:44 Integrated Voltage Measurement... 11:26:53 Voltage Offset Correction: v_off_ini = 166.913 uV, v_off_fin = 165.314 uV 11:26:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 181.004 uVs 11:26:53 Integrated Voltage Measurement... 11:27:02 Voltage Offset Correction: v_off_ini = 182.273 uV, v_off_fin = 181.000 uV 11:27:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.293 uVs 11:27:02 Integrated Voltage Measurement... 11:27:11 Voltage Offset Correction: v_off_ini = 193.913 uV, v_off_fin = 189.923 uV 11:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.573 uVs 11:27:15 I1X Average and RMS of Measurements VT = -179.397 +- 3.542 uVs I1X = 35.882 +- 0.711 uTm 11:27:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:22 Integrated Voltage Measurement... 11:27:31 Voltage Offset Correction: v_off_ini = 155.815 uV, v_off_fin = 164.513 uV 11:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.706 uVs 11:27:31 Integrated Voltage Measurement... 11:27:40 Voltage Offset Correction: v_off_ini = 169.213 uV, v_off_fin = 189.593 uV 11:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 224.213 uVs 11:27:40 Integrated Voltage Measurement... 11:27:49 Voltage Offset Correction: v_off_ini = 173.011 uV, v_off_fin = 138.463 uV 11:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.819 uVs 11:27:49 Integrated Voltage Measurement... 11:27:58 Voltage Offset Correction: v_off_ini = 172.378 uV, v_off_fin = 187.943 uV 11:27:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.964 uVs 11:27:58 Integrated Voltage Measurement... 11:28:07 Voltage Offset Correction: v_off_ini = 175.592 uV, v_off_fin = 171.885 uV 11:28:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.552 uVs 11:28:07 Integrated Voltage Measurement... 11:28:16 Voltage Offset Correction: v_off_ini = 172.101 uV, v_off_fin = 188.428 uV 11:28:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 208.441 uVs 11:28:20 I1Y Average and RMS of Measurements VT = -213.783 +- 2.101 uVs I1Y = -42.751 +- 0.420 uTm 11:28:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:27 Integrated Voltage Measurement... 11:28:36 Voltage Offset Correction: v_off_ini = 171.532 uV, v_off_fin = 161.403 uV 11:28:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -183.305 uVs 11:28:37 Integrated Voltage Measurement... 11:28:46 Voltage Offset Correction: v_off_ini = 168.954 uV, v_off_fin = 178.133 uV 11:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 202.344 uVs 11:28:46 Integrated Voltage Measurement... 11:28:55 Voltage Offset Correction: v_off_ini = 172.209 uV, v_off_fin = 174.171 uV 11:28:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -194.623 uVs 11:28:55 Integrated Voltage Measurement... 11:29:04 Voltage Offset Correction: v_off_ini = 182.758 uV, v_off_fin = 188.829 uV 11:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.621 uVs 11:29:04 Integrated Voltage Measurement... 11:29:13 Voltage Offset Correction: v_off_ini = 182.925 uV, v_off_fin = 173.200 uV 11:29:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -188.747 uVs 11:29:13 Integrated Voltage Measurement... 11:29:22 Voltage Offset Correction: v_off_ini = 182.658 uV, v_off_fin = 170.352 uV 11:29:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 208.251 uVs 11:29:24 I2X Average and RMS of Measurements VT = -194.149 +- 3.154 uVs I2X = 17.862 +- 0.290 uTm^2 11:29:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:32 Integrated Voltage Measurement... 11:29:41 Voltage Offset Correction: v_off_ini = 170.827 uV, v_off_fin = 174.344 uV 11:29:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.186 uVs 11:29:41 Integrated Voltage Measurement... 11:29:50 Voltage Offset Correction: v_off_ini = 173.281 uV, v_off_fin = 176.329 uV 11:29:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.506 uVs 11:29:50 Integrated Voltage Measurement... 11:29:59 Voltage Offset Correction: v_off_ini = 158.992 uV, v_off_fin = 170.725 uV 11:29:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.282 uVs 11:29:59 Integrated Voltage Measurement... 11:30:08 Voltage Offset Correction: v_off_ini = 186.094 uV, v_off_fin = 165.658 uV 11:30:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.064 uVs 11:30:08 Integrated Voltage Measurement... 11:30:17 Voltage Offset Correction: v_off_ini = 172.789 uV, v_off_fin = 169.840 uV 11:30:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.145 uVs 11:30:17 Integrated Voltage Measurement... 11:30:26 Voltage Offset Correction: v_off_ini = 167.519 uV, v_off_fin = 170.215 uV 11:30:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.144 uVs 11:30:28 I2Y Average and RMS of Measurements VT = -284.888 +- 1.990 uVs I2Y = -26.210 +- 0.183 uTm^2 11:30:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:47 Integrated Voltage Measurement... 11:30:56 Voltage Offset Correction: v_off_ini = 169.308 uV, v_off_fin = 169.615 uV 11:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -162.917 uVs 11:30:56 Integrated Voltage Measurement... 11:31:05 Voltage Offset Correction: v_off_ini = 173.850 uV, v_off_fin = 162.883 uV 11:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.237 uVs 11:31:05 Integrated Voltage Measurement... 11:31:14 Voltage Offset Correction: v_off_ini = 168.861 uV, v_off_fin = 168.291 uV 11:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.906 uVs 11:31:14 Integrated Voltage Measurement... 11:31:23 Voltage Offset Correction: v_off_ini = 173.667 uV, v_off_fin = 178.537 uV 11:31:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.643 uVs 11:31:23 Integrated Voltage Measurement... 11:31:32 Voltage Offset Correction: v_off_ini = 160.886 uV, v_off_fin = 158.704 uV 11:31:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.775 uVs 11:31:32 Integrated Voltage Measurement... 11:31:41 Voltage Offset Correction: v_off_ini = 169.735 uV, v_off_fin = 173.110 uV 11:31:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.067 uVs 11:31:45 I1X Average and RMS of Measurements VT = -157.924 +- 6.463 uVs I1X = 31.585 +- 1.293 uTm 11:31:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:52 Integrated Voltage Measurement... 11:32:01 Voltage Offset Correction: v_off_ini = 168.488 uV, v_off_fin = 164.397 uV 11:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.585 uVs 11:32:01 Integrated Voltage Measurement... 11:32:10 Voltage Offset Correction: v_off_ini = 157.642 uV, v_off_fin = 188.863 uV 11:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.191 uVs 11:32:10 Integrated Voltage Measurement... 11:32:19 Voltage Offset Correction: v_off_ini = 178.952 uV, v_off_fin = 164.727 uV 11:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.542 uVs 11:32:19 Integrated Voltage Measurement... 11:32:28 Voltage Offset Correction: v_off_ini = 163.078 uV, v_off_fin = 164.483 uV 11:32:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.679 uVs 11:32:28 Integrated Voltage Measurement... 11:32:37 Voltage Offset Correction: v_off_ini = 143.401 uV, v_off_fin = 146.436 uV 11:32:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.417 uVs 11:32:37 Integrated Voltage Measurement... 11:32:46 Voltage Offset Correction: v_off_ini = 160.452 uV, v_off_fin = 179.266 uV 11:32:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.090 uVs 11:32:50 I1Y Average and RMS of Measurements VT = -215.084 +- 1.456 uVs I1Y = -43.015 +- 0.293 uTm 11:32:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:58 Integrated Voltage Measurement... 11:33:07 Voltage Offset Correction: v_off_ini = 150.524 uV, v_off_fin = 153.578 uV 11:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.960 uVs 11:33:07 Integrated Voltage Measurement... 11:33:16 Voltage Offset Correction: v_off_ini = 155.335 uV, v_off_fin = 173.029 uV 11:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 172.971 uVs 11:33:16 Integrated Voltage Measurement... 11:33:25 Voltage Offset Correction: v_off_ini = 162.772 uV, v_off_fin = 150.257 uV 11:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.615 uVs 11:33:25 Integrated Voltage Measurement... 11:33:34 Voltage Offset Correction: v_off_ini = 159.567 uV, v_off_fin = 166.301 uV 11:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.125 uVs 11:33:34 Integrated Voltage Measurement... 11:33:43 Voltage Offset Correction: v_off_ini = 156.814 uV, v_off_fin = 142.838 uV 11:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.616 uVs 11:33:43 Integrated Voltage Measurement... 11:33:52 Voltage Offset Correction: v_off_ini = 161.239 uV, v_off_fin = 185.612 uV 11:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.122 uVs 11:33:54 I2X Average and RMS of Measurements VT = -167.235 +- 7.260 uVs I2X = 15.386 +- 0.668 uTm^2 11:34:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:34:02 Integrated Voltage Measurement... 11:34:11 Voltage Offset Correction: v_off_ini = 159.857 uV, v_off_fin = 155.115 uV 11:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.368 uVs 11:34:11 Integrated Voltage Measurement... 11:34:20 Voltage Offset Correction: v_off_ini = 157.805 uV, v_off_fin = 147.850 uV 11:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.202 uVs 11:34:20 Integrated Voltage Measurement... 11:34:29 Voltage Offset Correction: v_off_ini = 156.591 uV, v_off_fin = 150.091 uV 11:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.481 uVs 11:34:29 Integrated Voltage Measurement... 11:34:38 Voltage Offset Correction: v_off_ini = 153.630 uV, v_off_fin = 154.665 uV 11:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.989 uVs 11:34:38 Integrated Voltage Measurement... 11:34:47 Voltage Offset Correction: v_off_ini = 151.044 uV, v_off_fin = 154.497 uV 11:34:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.319 uVs 11:34:47 Integrated Voltage Measurement... 11:34:56 Voltage Offset Correction: v_off_ini = 146.900 uV, v_off_fin = 154.807 uV 11:34:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.673 uVs 11:34:59 I2Y Average and RMS of Measurements VT = -274.005 +- 3.764 uVs I2Y = -25.208 +- 0.346 uTm^2 11:35:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:17 Integrated Voltage Measurement... 11:35:26 Voltage Offset Correction: v_off_ini = 175.274 uV, v_off_fin = 157.904 uV 11:35:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -174.999 uVs 11:35:26 Integrated Voltage Measurement... 11:35:35 Voltage Offset Correction: v_off_ini = 158.452 uV, v_off_fin = 171.856 uV 11:35:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 135.151 uVs 11:35:35 Integrated Voltage Measurement... 11:35:44 Voltage Offset Correction: v_off_ini = 173.267 uV, v_off_fin = 155.838 uV 11:35:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.331 uVs 11:35:44 Integrated Voltage Measurement... 11:35:53 Voltage Offset Correction: v_off_ini = 187.293 uV, v_off_fin = 179.008 uV 11:35:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 140.616 uVs 11:35:53 Integrated Voltage Measurement... 11:36:02 Voltage Offset Correction: v_off_ini = 169.160 uV, v_off_fin = 165.260 uV 11:36:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.979 uVs 11:36:02 Integrated Voltage Measurement... 11:36:11 Voltage Offset Correction: v_off_ini = 176.729 uV, v_off_fin = 181.329 uV 11:36:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.316 uVs 11:36:16 I1X Average and RMS of Measurements VT = -145.232 +- 7.091 uVs I1X = 29.049 +- 1.420 uTm 11:36:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:22 Integrated Voltage Measurement... 11:36:31 Voltage Offset Correction: v_off_ini = 176.678 uV, v_off_fin = 174.011 uV 11:36:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.720 uVs 11:36:31 Integrated Voltage Measurement... 11:36:40 Voltage Offset Correction: v_off_ini = 184.220 uV, v_off_fin = 197.738 uV 11:36:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.088 uVs 11:36:40 Integrated Voltage Measurement... 11:36:49 Voltage Offset Correction: v_off_ini = 188.176 uV, v_off_fin = 167.762 uV 11:36:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.317 uVs 11:36:49 Integrated Voltage Measurement... 11:36:58 Voltage Offset Correction: v_off_ini = 182.250 uV, v_off_fin = 206.759 uV 11:36:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.949 uVs 11:36:58 Integrated Voltage Measurement... 11:37:07 Voltage Offset Correction: v_off_ini = 188.765 uV, v_off_fin = 176.794 uV 11:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.207 uVs 11:37:07 Integrated Voltage Measurement... 11:37:16 Voltage Offset Correction: v_off_ini = 176.096 uV, v_off_fin = 191.770 uV 11:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.056 uVs 11:37:20 I1Y Average and RMS of Measurements VT = -217.390 +- 3.419 uVs I1Y = -43.478 +- 0.684 uTm 11:37:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:28 Integrated Voltage Measurement... 11:37:37 Voltage Offset Correction: v_off_ini = 190.286 uV, v_off_fin = 175.018 uV 11:37:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -172.868 uVs 11:37:37 Integrated Voltage Measurement... 11:37:46 Voltage Offset Correction: v_off_ini = 193.844 uV, v_off_fin = 200.079 uV 11:37:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.754 uVs 11:37:46 Integrated Voltage Measurement... 11:37:55 Voltage Offset Correction: v_off_ini = 193.596 uV, v_off_fin = 186.856 uV 11:37:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -173.949 uVs 11:37:55 Integrated Voltage Measurement... 11:38:04 Voltage Offset Correction: v_off_ini = 183.539 uV, v_off_fin = 197.193 uV 11:38:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.237 uVs 11:38:04 Integrated Voltage Measurement... 11:38:13 Voltage Offset Correction: v_off_ini = 192.878 uV, v_off_fin = 183.177 uV 11:38:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.485 uVs 11:38:13 Integrated Voltage Measurement... 11:38:22 Voltage Offset Correction: v_off_ini = 195.278 uV, v_off_fin = 194.627 uV 11:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 175.941 uVs 11:38:25 I2X Average and RMS of Measurements VT = -165.539 +- 1.999 uVs I2X = 15.229 +- 0.184 uTm^2 11:38:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:32 Integrated Voltage Measurement... 11:38:41 Voltage Offset Correction: v_off_ini = 201.611 uV, v_off_fin = 196.102 uV 11:38:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.663 uVs 11:38:41 Integrated Voltage Measurement... 11:38:50 Voltage Offset Correction: v_off_ini = 192.834 uV, v_off_fin = 198.680 uV 11:38:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.365 uVs 11:38:51 Integrated Voltage Measurement... 11:39:00 Voltage Offset Correction: v_off_ini = 193.141 uV, v_off_fin = 198.530 uV 11:39:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.697 uVs 11:39:00 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 188.559 uV, v_off_fin = 183.048 uV 11:39:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.463 uVs 11:39:09 Integrated Voltage Measurement... 11:39:18 Voltage Offset Correction: v_off_ini = 192.894 uV, v_off_fin = 191.188 uV 11:39:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.716 uVs 11:39:18 Integrated Voltage Measurement... 11:39:27 Voltage Offset Correction: v_off_ini = 191.464 uV, v_off_fin = 199.453 uV 11:39:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.453 uVs 11:39:29 I2Y Average and RMS of Measurements VT = -279.726 +- 4.934 uVs I2Y = -25.735 +- 0.454 uTm^2 11:39:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:47 Integrated Voltage Measurement... 11:39:56 Voltage Offset Correction: v_off_ini = 198.613 uV, v_off_fin = 194.943 uV 11:39:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.532 uVs 11:39:56 Integrated Voltage Measurement... 11:40:05 Voltage Offset Correction: v_off_ini = 207.798 uV, v_off_fin = 203.043 uV 11:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.286 uVs 11:40:05 Integrated Voltage Measurement... 11:40:14 Voltage Offset Correction: v_off_ini = 184.521 uV, v_off_fin = 181.317 uV 11:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.479 uVs 11:40:14 Integrated Voltage Measurement... 11:40:23 Voltage Offset Correction: v_off_ini = 180.975 uV, v_off_fin = 187.996 uV 11:40:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.585 uVs 11:40:23 Integrated Voltage Measurement... 11:40:32 Voltage Offset Correction: v_off_ini = 197.423 uV, v_off_fin = 188.697 uV 11:40:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.677 uVs 11:40:33 Integrated Voltage Measurement... 11:40:41 Voltage Offset Correction: v_off_ini = 211.034 uV, v_off_fin = 199.625 uV 11:40:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 125.203 uVs 11:40:46 I1X Average and RMS of Measurements VT = -140.460 +- 8.173 uVs I1X = 28.094 +- 1.633 uTm 11:40:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:53 Integrated Voltage Measurement... 11:41:01 Voltage Offset Correction: v_off_ini = 203.444 uV, v_off_fin = 185.454 uV 11:41:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.923 uVs 11:41:02 Integrated Voltage Measurement... 11:41:10 Voltage Offset Correction: v_off_ini = 204.493 uV, v_off_fin = 223.430 uV 11:41:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.504 uVs 11:41:11 Integrated Voltage Measurement... 11:41:19 Voltage Offset Correction: v_off_ini = 184.859 uV, v_off_fin = 182.369 uV 11:41:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.058 uVs 11:41:20 Integrated Voltage Measurement... 11:41:28 Voltage Offset Correction: v_off_ini = 189.856 uV, v_off_fin = 199.947 uV 11:41:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.540 uVs 11:41:29 Integrated Voltage Measurement... 11:41:37 Voltage Offset Correction: v_off_ini = 184.479 uV, v_off_fin = 182.257 uV 11:41:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.655 uVs 11:41:38 Integrated Voltage Measurement... 11:41:46 Voltage Offset Correction: v_off_ini = 185.035 uV, v_off_fin = 199.403 uV 11:41:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.835 uVs 11:41:51 I1Y Average and RMS of Measurements VT = -207.753 +- 3.066 uVs I1Y = -41.548 +- 0.615 uTm 11:41:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:58 Integrated Voltage Measurement... 11:42:07 Voltage Offset Correction: v_off_ini = 207.474 uV, v_off_fin = 201.354 uV 11:42:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.200 uVs 11:42:07 Integrated Voltage Measurement... 11:42:16 Voltage Offset Correction: v_off_ini = 199.784 uV, v_off_fin = 197.787 uV 11:42:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.723 uVs 11:42:17 Integrated Voltage Measurement... 11:42:25 Voltage Offset Correction: v_off_ini = 205.227 uV, v_off_fin = 192.859 uV 11:42:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.902 uVs 11:42:26 Integrated Voltage Measurement... 11:42:35 Voltage Offset Correction: v_off_ini = 197.043 uV, v_off_fin = 211.806 uV 11:42:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 169.967 uVs 11:42:35 Integrated Voltage Measurement... 11:42:44 Voltage Offset Correction: v_off_ini = 211.108 uV, v_off_fin = 182.329 uV 11:42:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.588 uVs 11:42:44 Integrated Voltage Measurement... 11:42:53 Voltage Offset Correction: v_off_ini = 191.482 uV, v_off_fin = 220.139 uV 11:42:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 174.774 uVs 11:42:55 I2X Average and RMS of Measurements VT = -154.192 +- 14.916 uVs I2X = 14.186 +- 1.372 uTm^2 11:43:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:43:03 Integrated Voltage Measurement... 11:43:12 Voltage Offset Correction: v_off_ini = 208.377 uV, v_off_fin = 213.996 uV 11:43:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.048 uVs 11:43:12 Integrated Voltage Measurement... 11:43:21 Voltage Offset Correction: v_off_ini = 197.947 uV, v_off_fin = 202.197 uV 11:43:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.935 uVs 11:43:21 Integrated Voltage Measurement... 11:43:30 Voltage Offset Correction: v_off_ini = 196.348 uV, v_off_fin = 200.849 uV 11:43:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.670 uVs 11:43:30 Integrated Voltage Measurement... 11:43:39 Voltage Offset Correction: v_off_ini = 197.993 uV, v_off_fin = 201.216 uV 11:43:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.753 uVs 11:43:39 Integrated Voltage Measurement... 11:43:48 Voltage Offset Correction: v_off_ini = 206.730 uV, v_off_fin = 195.470 uV 11:43:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.334 uVs 11:43:48 Integrated Voltage Measurement... 11:43:57 Voltage Offset Correction: v_off_ini = 199.584 uV, v_off_fin = 195.509 uV 11:43:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.083 uVs 11:43:59 I2Y Average and RMS of Measurements VT = -269.137 +- 9.295 uVs I2Y = -24.761 +- 0.855 uTm^2 11:44:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:18 Integrated Voltage Measurement... 11:44:27 Voltage Offset Correction: v_off_ini = 188.553 uV, v_off_fin = 198.751 uV 11:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -124.656 uVs 11:44:27 Integrated Voltage Measurement... 11:44:36 Voltage Offset Correction: v_off_ini = 186.638 uV, v_off_fin = 199.102 uV 11:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.935 uVs 11:44:36 Integrated Voltage Measurement... 11:44:45 Voltage Offset Correction: v_off_ini = 185.990 uV, v_off_fin = 190.166 uV 11:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.775 uVs 11:44:45 Integrated Voltage Measurement... 11:44:54 Voltage Offset Correction: v_off_ini = 199.289 uV, v_off_fin = 200.930 uV 11:44:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.081 uVs 11:44:54 Integrated Voltage Measurement... 11:45:03 Voltage Offset Correction: v_off_ini = 197.396 uV, v_off_fin = 201.289 uV 11:45:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.826 uVs 11:45:03 Integrated Voltage Measurement... 11:45:12 Voltage Offset Correction: v_off_ini = 214.314 uV, v_off_fin = 207.197 uV 11:45:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.314 uVs 11:45:16 I1X Average and RMS of Measurements VT = -124.764 +- 5.752 uVs I1X = 24.954 +- 1.150 uTm 11:45:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:23 Integrated Voltage Measurement... 11:45:32 Voltage Offset Correction: v_off_ini = 197.133 uV, v_off_fin = 184.559 uV 11:45:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.127 uVs 11:45:32 Integrated Voltage Measurement... 11:45:41 Voltage Offset Correction: v_off_ini = 180.265 uV, v_off_fin = 197.425 uV 11:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 236.497 uVs 11:45:41 Integrated Voltage Measurement... 11:45:50 Voltage Offset Correction: v_off_ini = 178.774 uV, v_off_fin = 168.089 uV 11:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.951 uVs 11:45:50 Integrated Voltage Measurement... 11:45:59 Voltage Offset Correction: v_off_ini = 168.194 uV, v_off_fin = 192.122 uV 11:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.612 uVs 11:45:59 Integrated Voltage Measurement... 11:46:08 Voltage Offset Correction: v_off_ini = 180.230 uV, v_off_fin = 160.398 uV 11:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.366 uVs 11:46:08 Integrated Voltage Measurement... 11:46:17 Voltage Offset Correction: v_off_ini = 181.954 uV, v_off_fin = 175.383 uV 11:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.856 uVs 11:46:21 I1Y Average and RMS of Measurements VT = -215.401 +- 7.720 uVs I1Y = -43.076 +- 1.544 uTm 11:46:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:29 Integrated Voltage Measurement... 11:46:38 Voltage Offset Correction: v_off_ini = 170.063 uV, v_off_fin = 162.828 uV 11:46:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -118.313 uVs 11:46:38 Integrated Voltage Measurement... 11:46:47 Voltage Offset Correction: v_off_ini = 177.732 uV, v_off_fin = 188.941 uV 11:46:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.386 uVs 11:46:47 Integrated Voltage Measurement... 11:46:56 Voltage Offset Correction: v_off_ini = 176.202 uV, v_off_fin = 169.271 uV 11:46:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.653 uVs 11:46:56 Integrated Voltage Measurement... 11:47:05 Voltage Offset Correction: v_off_ini = 184.852 uV, v_off_fin = 187.394 uV 11:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.594 uVs 11:47:05 Integrated Voltage Measurement... 11:47:14 Voltage Offset Correction: v_off_ini = 183.633 uV, v_off_fin = 157.162 uV 11:47:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.419 uVs 11:47:14 Integrated Voltage Measurement... 11:47:23 Voltage Offset Correction: v_off_ini = 174.667 uV, v_off_fin = 182.967 uV 11:47:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.310 uVs 11:47:25 I2X Average and RMS of Measurements VT = -128.446 +- 6.786 uVs I2X = 11.817 +- 0.625 uTm^2 11:47:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:33 Integrated Voltage Measurement... 11:47:42 Voltage Offset Correction: v_off_ini = 182.818 uV, v_off_fin = 189.394 uV 11:47:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.207 uVs 11:47:42 Integrated Voltage Measurement... 11:47:51 Voltage Offset Correction: v_off_ini = 200.193 uV, v_off_fin = 189.402 uV 11:47:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.636 uVs 11:47:51 Integrated Voltage Measurement... 11:48:00 Voltage Offset Correction: v_off_ini = 201.515 uV, v_off_fin = 204.002 uV 11:48:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.869 uVs 11:48:00 Integrated Voltage Measurement... 11:48:09 Voltage Offset Correction: v_off_ini = 189.206 uV, v_off_fin = 196.965 uV 11:48:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.073 uVs 11:48:09 Integrated Voltage Measurement... 11:48:18 Voltage Offset Correction: v_off_ini = 189.550 uV, v_off_fin = 189.083 uV 11:48:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.178 uVs 11:48:18 Integrated Voltage Measurement... 11:48:27 Voltage Offset Correction: v_off_ini = 203.407 uV, v_off_fin = 202.130 uV 11:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.415 uVs 11:48:30 I2Y Average and RMS of Measurements VT = -264.730 +- 3.765 uVs I2Y = -24.355 +- 0.346 uTm^2 11:48:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:48 Integrated Voltage Measurement... 11:48:57 Voltage Offset Correction: v_off_ini = 185.681 uV, v_off_fin = 186.204 uV 11:48:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.922 uVs 11:48:57 Integrated Voltage Measurement... 11:49:06 Voltage Offset Correction: v_off_ini = 184.441 uV, v_off_fin = 196.245 uV 11:49:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.145 uVs 11:49:06 Integrated Voltage Measurement... 11:49:15 Voltage Offset Correction: v_off_ini = 193.537 uV, v_off_fin = 188.367 uV 11:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.570 uVs 11:49:15 Integrated Voltage Measurement... 11:49:24 Voltage Offset Correction: v_off_ini = 197.847 uV, v_off_fin = 190.473 uV 11:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.155 uVs 11:49:24 Integrated Voltage Measurement... 11:49:33 Voltage Offset Correction: v_off_ini = 199.496 uV, v_off_fin = 203.648 uV 11:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.999 uVs 11:49:33 Integrated Voltage Measurement... 11:49:42 Voltage Offset Correction: v_off_ini = 199.625 uV, v_off_fin = 199.817 uV 11:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.072 uVs 11:49:46 I1X Average and RMS of Measurements VT = -113.977 +- 5.862 uVs I1X = 22.796 +- 1.173 uTm 11:49:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:53 Integrated Voltage Measurement... 11:50:02 Voltage Offset Correction: v_off_ini = 203.779 uV, v_off_fin = 188.947 uV 11:50:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.237 uVs 11:50:02 Integrated Voltage Measurement... 11:50:11 Voltage Offset Correction: v_off_ini = 219.016 uV, v_off_fin = 212.192 uV 11:50:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.836 uVs 11:50:11 Integrated Voltage Measurement... 11:50:20 Voltage Offset Correction: v_off_ini = 208.014 uV, v_off_fin = 187.281 uV 11:50:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.991 uVs 11:50:20 Integrated Voltage Measurement... 11:50:29 Voltage Offset Correction: v_off_ini = 192.816 uV, v_off_fin = 213.921 uV 11:50:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.072 uVs 11:50:29 Integrated Voltage Measurement... 11:50:38 Voltage Offset Correction: v_off_ini = 181.299 uV, v_off_fin = 171.598 uV 11:50:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.217 uVs 11:50:38 Integrated Voltage Measurement... 11:50:47 Voltage Offset Correction: v_off_ini = 185.883 uV, v_off_fin = 195.013 uV 11:50:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.715 uVs 11:50:51 I1Y Average and RMS of Measurements VT = -219.178 +- 3.954 uVs I1Y = -43.831 +- 0.791 uTm 11:50:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:59 Integrated Voltage Measurement... 11:51:08 Voltage Offset Correction: v_off_ini = 183.819 uV, v_off_fin = 172.717 uV 11:51:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -115.363 uVs 11:51:08 Integrated Voltage Measurement... 11:51:17 Voltage Offset Correction: v_off_ini = 181.538 uV, v_off_fin = 208.670 uV 11:51:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.974 uVs 11:51:17 Integrated Voltage Measurement... 11:51:26 Voltage Offset Correction: v_off_ini = 198.783 uV, v_off_fin = 188.580 uV 11:51:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.237 uVs 11:51:26 Integrated Voltage Measurement... 11:51:35 Voltage Offset Correction: v_off_ini = 184.404 uV, v_off_fin = 193.756 uV 11:51:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.269 uVs 11:51:35 Integrated Voltage Measurement... 11:51:44 Voltage Offset Correction: v_off_ini = 196.419 uV, v_off_fin = 180.319 uV 11:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.071 uVs 11:51:44 Integrated Voltage Measurement... 11:51:53 Voltage Offset Correction: v_off_ini = 178.508 uV, v_off_fin = 193.934 uV 11:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.257 uVs 11:51:56 I2X Average and RMS of Measurements VT = -127.029 +- 7.403 uVs I2X = 11.686 +- 0.681 uTm^2 11:52:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:52:03 Integrated Voltage Measurement... 11:52:12 Voltage Offset Correction: v_off_ini = 200.760 uV, v_off_fin = 199.063 uV 11:52:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -264.681 uVs 11:52:12 Integrated Voltage Measurement... 11:52:21 Voltage Offset Correction: v_off_ini = 201.743 uV, v_off_fin = 198.263 uV 11:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.827 uVs 11:52:21 Integrated Voltage Measurement... 11:52:30 Voltage Offset Correction: v_off_ini = 199.630 uV, v_off_fin = 200.146 uV 11:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.615 uVs 11:52:30 Integrated Voltage Measurement... 11:52:39 Voltage Offset Correction: v_off_ini = 192.855 uV, v_off_fin = 189.572 uV 11:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.073 uVs 11:52:39 Integrated Voltage Measurement... 11:52:48 Voltage Offset Correction: v_off_ini = 193.700 uV, v_off_fin = 191.507 uV 11:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.088 uVs 11:52:49 Integrated Voltage Measurement... 11:52:57 Voltage Offset Correction: v_off_ini = 202.056 uV, v_off_fin = 196.591 uV 11:52:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.842 uVs 11:53:00 I2Y Average and RMS of Measurements VT = -253.854 +- 3.614 uVs I2Y = -23.355 +- 0.332 uTm^2 11:53:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm