SLAC Magnetic Measurements Date: 04-22-2025 Time: 16:28:56 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE-SXPS_16348 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 6 Measurement Device: Operator: YL Comment: Tuning 16:29:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:06 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:29:07 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:29:09 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:29:10 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:48 Integrated Voltage Measurement... 16:29:57 Voltage Offset Correction: v_off_ini = -367.475 uV, v_off_fin = -357.033 uV 16:29:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.840 uVs 16:29:57 Integrated Voltage Measurement... 16:30:06 Voltage Offset Correction: v_off_ini = -357.778 uV, v_off_fin = -349.278 uV 16:30:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.673 uVs 16:30:06 Integrated Voltage Measurement... 16:30:15 Voltage Offset Correction: v_off_ini = -352.899 uV, v_off_fin = -338.624 uV 16:30:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.158 uVs 16:30:15 Integrated Voltage Measurement... 16:30:24 Voltage Offset Correction: v_off_ini = -337.425 uV, v_off_fin = -324.112 uV 16:30:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.053 uVs 16:30:24 Integrated Voltage Measurement... 16:30:33 Voltage Offset Correction: v_off_ini = -326.846 uV, v_off_fin = -326.478 uV 16:30:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.938 uVs 16:30:33 Integrated Voltage Measurement... 16:30:42 Voltage Offset Correction: v_off_ini = -320.921 uV, v_off_fin = -322.006 uV 16:30:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.362 uVs 16:30:46 I1X Average and RMS of Measurements VT = -75.337 +- 7.296 uVs I1X = 15.068 +- 1.459 uTm 16:30:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:53 Integrated Voltage Measurement... 16:31:02 Voltage Offset Correction: v_off_ini = -310.104 uV, v_off_fin = -319.848 uV 16:31:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -222.128 uVs 16:31:02 Integrated Voltage Measurement... 16:31:11 Voltage Offset Correction: v_off_ini = -303.113 uV, v_off_fin = -292.840 uV 16:31:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.223 uVs 16:31:11 Integrated Voltage Measurement... 16:31:20 Voltage Offset Correction: v_off_ini = -312.491 uV, v_off_fin = -320.634 uV 16:31:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.424 uVs 16:31:20 Integrated Voltage Measurement... 16:31:29 Voltage Offset Correction: v_off_ini = -285.906 uV, v_off_fin = -277.185 uV 16:31:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.350 uVs 16:31:29 Integrated Voltage Measurement... 16:31:38 Voltage Offset Correction: v_off_ini = -297.918 uV, v_off_fin = -300.852 uV 16:31:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.163 uVs 16:31:38 Integrated Voltage Measurement... 16:31:47 Voltage Offset Correction: v_off_ini = -275.379 uV, v_off_fin = -267.962 uV 16:31:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.575 uVs 16:31:51 I1Y Average and RMS of Measurements VT = -232.477 +- 2.077 uVs I1Y = -46.494 +- 0.415 uTm 16:31:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:59 Integrated Voltage Measurement... 16:32:08 Voltage Offset Correction: v_off_ini = -263.887 uV, v_off_fin = -252.225 uV 16:32:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -80.557 uVs 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = -251.139 uV, v_off_fin = -249.011 uV 16:32:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.936 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = -245.038 uV, v_off_fin = -226.941 uV 16:32:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.495 uVs 16:32:26 Integrated Voltage Measurement... 16:32:35 Voltage Offset Correction: v_off_ini = -226.072 uV, v_off_fin = -238.213 uV 16:32:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.657 uVs 16:32:35 Integrated Voltage Measurement... 16:32:44 Voltage Offset Correction: v_off_ini = -230.586 uV, v_off_fin = -238.257 uV 16:32:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.802 uVs 16:32:44 Integrated Voltage Measurement... 16:32:53 Voltage Offset Correction: v_off_ini = -230.993 uV, v_off_fin = -243.052 uV 16:32:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.364 uVs 16:32:56 I2X Average and RMS of Measurements VT = -85.468 +- 0.687 uVs I2X = 7.863 +- 0.063 uTm^2 16:33:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:03 Integrated Voltage Measurement... 16:33:12 Voltage Offset Correction: v_off_ini = -241.756 uV, v_off_fin = -222.263 uV 16:33:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.466 uVs 16:33:12 Integrated Voltage Measurement... 16:33:21 Voltage Offset Correction: v_off_ini = -224.836 uV, v_off_fin = -211.376 uV 16:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.652 uVs 16:33:21 Integrated Voltage Measurement... 16:33:30 Voltage Offset Correction: v_off_ini = -226.637 uV, v_off_fin = -214.049 uV 16:33:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.310 uVs 16:33:30 Integrated Voltage Measurement... 16:33:39 Voltage Offset Correction: v_off_ini = -221.599 uV, v_off_fin = -209.070 uV 16:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.836 uVs 16:33:39 Integrated Voltage Measurement... 16:33:48 Voltage Offset Correction: v_off_ini = -214.324 uV, v_off_fin = -209.436 uV 16:33:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.147 uVs 16:33:48 Integrated Voltage Measurement... 16:33:57 Voltage Offset Correction: v_off_ini = -202.648 uV, v_off_fin = -223.584 uV 16:33:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.337 uVs 16:34:00 I2Y Average and RMS of Measurements VT = -234.291 +- 12.427 uVs I2Y = -21.555 +- 1.143 uTm^2 16:34:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:14 Integrated Voltage Measurement... 16:34:23 Voltage Offset Correction: v_off_ini = -218.087 uV, v_off_fin = -210.970 uV 16:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.349 uVs 16:34:23 Integrated Voltage Measurement... 16:34:32 Voltage Offset Correction: v_off_ini = -199.854 uV, v_off_fin = -218.905 uV 16:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.798 uVs 16:34:32 Integrated Voltage Measurement... 16:34:41 Voltage Offset Correction: v_off_ini = -202.571 uV, v_off_fin = -199.770 uV 16:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.823 uVs 16:34:41 Integrated Voltage Measurement... 16:34:50 Voltage Offset Correction: v_off_ini = -206.112 uV, v_off_fin = -188.847 uV 16:34:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.641 uVs 16:34:50 Integrated Voltage Measurement... 16:34:59 Voltage Offset Correction: v_off_ini = -200.240 uV, v_off_fin = -192.581 uV 16:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.285 uVs 16:34:59 Integrated Voltage Measurement... 16:35:08 Voltage Offset Correction: v_off_ini = -187.916 uV, v_off_fin = -187.204 uV 16:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.647 uVs 16:35:12 I1X Average and RMS of Measurements VT = -74.257 +- 8.996 uVs I1X = 14.851 +- 1.799 uTm 16:35:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:19 Integrated Voltage Measurement... 16:35:28 Voltage Offset Correction: v_off_ini = -183.522 uV, v_off_fin = -207.792 uV 16:35:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.334 uVs 16:35:28 Integrated Voltage Measurement... 16:35:37 Voltage Offset Correction: v_off_ini = -199.336 uV, v_off_fin = -188.224 uV 16:35:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.863 uVs 16:35:37 Integrated Voltage Measurement... 16:35:46 Voltage Offset Correction: v_off_ini = -193.050 uV, v_off_fin = -198.002 uV 16:35:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.773 uVs 16:35:46 Integrated Voltage Measurement... 16:35:55 Voltage Offset Correction: v_off_ini = -208.955 uV, v_off_fin = -203.319 uV 16:35:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.828 uVs 16:35:55 Integrated Voltage Measurement... 16:36:04 Voltage Offset Correction: v_off_ini = -202.640 uV, v_off_fin = -210.005 uV 16:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.444 uVs 16:36:04 Integrated Voltage Measurement... 16:36:13 Voltage Offset Correction: v_off_ini = -189.904 uV, v_off_fin = -184.851 uV 16:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.247 uVs 16:36:17 I1Y Average and RMS of Measurements VT = -215.415 +- 2.414 uVs I1Y = -43.082 +- 0.482 uTm 16:36:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:25 Integrated Voltage Measurement... 16:36:34 Voltage Offset Correction: v_off_ini = -197.418 uV, v_off_fin = -188.225 uV 16:36:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -78.613 uVs 16:36:34 Integrated Voltage Measurement... 16:36:43 Voltage Offset Correction: v_off_ini = -223.256 uV, v_off_fin = -205.542 uV 16:36:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.244 uVs 16:36:43 Integrated Voltage Measurement... 16:36:52 Voltage Offset Correction: v_off_ini = -190.308 uV, v_off_fin = -180.089 uV 16:36:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.862 uVs 16:36:52 Integrated Voltage Measurement... 16:37:01 Voltage Offset Correction: v_off_ini = -187.359 uV, v_off_fin = -213.429 uV 16:37:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.992 uVs 16:37:01 Integrated Voltage Measurement... 16:37:10 Voltage Offset Correction: v_off_ini = -184.618 uV, v_off_fin = -191.560 uV 16:37:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.720 uVs 16:37:10 Integrated Voltage Measurement... 16:37:19 Voltage Offset Correction: v_off_ini = -190.306 uV, v_off_fin = -183.166 uV 16:37:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.423 uVs 16:37:22 I2X Average and RMS of Measurements VT = -79.309 +- 6.739 uVs I2X = 7.296 +- 0.620 uTm^2 16:37:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:29 Integrated Voltage Measurement... 16:37:38 Voltage Offset Correction: v_off_ini = -192.026 uV, v_off_fin = -195.498 uV 16:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.750 uVs 16:37:38 Integrated Voltage Measurement... 16:37:47 Voltage Offset Correction: v_off_ini = -200.901 uV, v_off_fin = -188.071 uV 16:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.883 uVs 16:37:47 Integrated Voltage Measurement... 16:37:56 Voltage Offset Correction: v_off_ini = -199.879 uV, v_off_fin = -203.434 uV 16:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.933 uVs 16:37:57 Integrated Voltage Measurement... 16:38:05 Voltage Offset Correction: v_off_ini = -219.320 uV, v_off_fin = -210.179 uV 16:38:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.765 uVs 16:38:06 Integrated Voltage Measurement... 16:38:15 Voltage Offset Correction: v_off_ini = -202.216 uV, v_off_fin = -196.468 uV 16:38:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.859 uVs 16:38:15 Integrated Voltage Measurement... 16:38:24 Voltage Offset Correction: v_off_ini = -201.695 uV, v_off_fin = -192.380 uV 16:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.825 uVs 16:38:26 I2Y Average and RMS of Measurements VT = -216.669 +- 4.723 uVs I2Y = -19.934 +- 0.435 uTm^2 16:38:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:40 Integrated Voltage Measurement... 16:38:49 Voltage Offset Correction: v_off_ini = -189.964 uV, v_off_fin = -181.023 uV 16:38:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.673 uVs 16:38:49 Integrated Voltage Measurement... 16:38:58 Voltage Offset Correction: v_off_ini = -194.059 uV, v_off_fin = -197.118 uV 16:38:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.462 uVs 16:38:58 Integrated Voltage Measurement... 16:39:07 Voltage Offset Correction: v_off_ini = -167.657 uV, v_off_fin = -188.911 uV 16:39:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.483 uVs 16:39:07 Integrated Voltage Measurement... 16:39:16 Voltage Offset Correction: v_off_ini = -190.302 uV, v_off_fin = -183.387 uV 16:39:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.590 uVs 16:39:16 Integrated Voltage Measurement... 16:39:25 Voltage Offset Correction: v_off_ini = -207.868 uV, v_off_fin = -188.019 uV 16:39:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.591 uVs 16:39:25 Integrated Voltage Measurement... 16:39:34 Voltage Offset Correction: v_off_ini = -180.929 uV, v_off_fin = -181.144 uV 16:39:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.797 uVs 16:39:38 I1X Average and RMS of Measurements VT = -61.599 +- 9.712 uVs I1X = 12.320 +- 1.942 uTm 16:39:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:45 Integrated Voltage Measurement... 16:39:54 Voltage Offset Correction: v_off_ini = -194.521 uV, v_off_fin = -201.611 uV 16:39:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.987 uVs 16:39:54 Integrated Voltage Measurement... 16:40:03 Voltage Offset Correction: v_off_ini = -186.363 uV, v_off_fin = -177.353 uV 16:40:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.769 uVs 16:40:03 Integrated Voltage Measurement... 16:40:12 Voltage Offset Correction: v_off_ini = -191.101 uV, v_off_fin = -204.681 uV 16:40:12 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -187.123 uVs 16:40:12 Integrated Voltage Measurement... 16:40:21 Voltage Offset Correction: v_off_ini = -197.751 uV, v_off_fin = -184.528 uV 16:40:21 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 194.905 uVs 16:40:21 Integrated Voltage Measurement... 16:40:30 Voltage Offset Correction: v_off_ini = -198.395 uV, v_off_fin = -213.097 uV 16:40:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.815 uVs 16:40:30 Integrated Voltage Measurement... 16:40:39 Voltage Offset Correction: v_off_ini = -199.844 uV, v_off_fin = -186.131 uV 16:40:39 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 202.449 uVs 16:40:43 I1Y Average and RMS of Measurements VT = -193.841 +- 2.023 uVs I1Y = -38.763 +- 0.406 uTm 16:40:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:51 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = -191.582 uV, v_off_fin = -187.607 uV 16:41:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -81.880 uVs 16:41:00 Integrated Voltage Measurement... 16:41:09 Voltage Offset Correction: v_off_ini = -197.948 uV, v_off_fin = -207.602 uV 16:41:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.445 uVs 16:41:09 Integrated Voltage Measurement... 16:41:18 Voltage Offset Correction: v_off_ini = -181.356 uV, v_off_fin = -185.547 uV 16:41:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.062 uVs 16:41:18 Integrated Voltage Measurement... 16:41:27 Voltage Offset Correction: v_off_ini = -188.945 uV, v_off_fin = -208.454 uV 16:41:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.988 uVs 16:41:27 Integrated Voltage Measurement... 16:41:36 Voltage Offset Correction: v_off_ini = -187.007 uV, v_off_fin = -182.613 uV 16:41:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.874 uVs 16:41:36 Integrated Voltage Measurement... 16:41:45 Voltage Offset Correction: v_off_ini = -202.991 uV, v_off_fin = -200.074 uV 16:41:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.082 uVs 16:41:48 I2X Average and RMS of Measurements VT = -70.722 +- 2.974 uVs I2X = 6.506 +- 0.274 uTm^2 16:41:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:55 Integrated Voltage Measurement... 16:42:04 Voltage Offset Correction: v_off_ini = -192.049 uV, v_off_fin = -208.546 uV 16:42:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.450 uVs 16:42:04 Integrated Voltage Measurement... 16:42:13 Voltage Offset Correction: v_off_ini = -197.604 uV, v_off_fin = -190.797 uV 16:42:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.964 uVs 16:42:13 Integrated Voltage Measurement... 16:42:22 Voltage Offset Correction: v_off_ini = -195.710 uV, v_off_fin = -201.061 uV 16:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.018 uVs 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = -196.050 uV, v_off_fin = -194.234 uV 16:42:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.071 uVs 16:42:32 Integrated Voltage Measurement... 16:42:41 Voltage Offset Correction: v_off_ini = -213.077 uV, v_off_fin = -207.041 uV 16:42:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.578 uVs 16:42:41 Integrated Voltage Measurement... 16:42:50 Voltage Offset Correction: v_off_ini = -209.927 uV, v_off_fin = -214.100 uV 16:42:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.865 uVs 16:42:52 I2Y Average and RMS of Measurements VT = -202.324 +- 0.980 uVs I2Y = -18.614 +- 0.090 uTm^2 16:43:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:06 Integrated Voltage Measurement... 16:43:15 Voltage Offset Correction: v_off_ini = -201.881 uV, v_off_fin = -194.528 uV 16:43:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.653 uVs 16:43:15 Integrated Voltage Measurement... 16:43:24 Voltage Offset Correction: v_off_ini = -184.014 uV, v_off_fin = -168.776 uV 16:43:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.177 uVs 16:43:24 Integrated Voltage Measurement... 16:43:33 Voltage Offset Correction: v_off_ini = -183.089 uV, v_off_fin = -191.196 uV 16:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.191 uVs 16:43:33 Integrated Voltage Measurement... 16:43:42 Voltage Offset Correction: v_off_ini = -185.387 uV, v_off_fin = -185.667 uV 16:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.317 uVs 16:43:42 Integrated Voltage Measurement... 16:43:51 Voltage Offset Correction: v_off_ini = -178.220 uV, v_off_fin = -177.970 uV 16:43:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.531 uVs 16:43:51 Integrated Voltage Measurement... 16:44:00 Voltage Offset Correction: v_off_ini = -166.222 uV, v_off_fin = -165.288 uV 16:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.005 uVs 16:44:04 I1X Average and RMS of Measurements VT = -56.312 +- 5.059 uVs I1X = 11.262 +- 1.012 uTm 16:44:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:11 Integrated Voltage Measurement... 16:44:20 Voltage Offset Correction: v_off_ini = -172.434 uV, v_off_fin = -179.523 uV 16:44:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.837 uVs 16:44:20 Integrated Voltage Measurement... 16:44:29 Voltage Offset Correction: v_off_ini = -171.470 uV, v_off_fin = -152.070 uV 16:44:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.618 uVs 16:44:29 Integrated Voltage Measurement... 16:44:38 Voltage Offset Correction: v_off_ini = -169.705 uV, v_off_fin = -175.851 uV 16:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.374 uVs 16:44:38 Integrated Voltage Measurement... 16:44:47 Voltage Offset Correction: v_off_ini = -171.713 uV, v_off_fin = -165.420 uV 16:44:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.610 uVs 16:44:47 Integrated Voltage Measurement... 16:44:56 Voltage Offset Correction: v_off_ini = -159.269 uV, v_off_fin = -187.793 uV 16:44:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.475 uVs 16:44:56 Integrated Voltage Measurement... 16:45:05 Voltage Offset Correction: v_off_ini = -159.259 uV, v_off_fin = -159.659 uV 16:45:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.007 uVs 16:45:10 I1Y Average and RMS of Measurements VT = -188.653 +- 6.524 uVs I1Y = -37.729 +- 1.306 uTm 16:45:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:17 Integrated Voltage Measurement... 16:45:26 Voltage Offset Correction: v_off_ini = -144.694 uV, v_off_fin = -140.071 uV 16:45:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.855 uVs 16:45:26 Integrated Voltage Measurement... 16:45:35 Voltage Offset Correction: v_off_ini = -145.616 uV, v_off_fin = -158.150 uV 16:45:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.810 uVs 16:45:36 Integrated Voltage Measurement... 16:45:44 Voltage Offset Correction: v_off_ini = -159.890 uV, v_off_fin = -139.569 uV 16:45:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.129 uVs 16:45:45 Integrated Voltage Measurement... 16:45:54 Voltage Offset Correction: v_off_ini = -149.612 uV, v_off_fin = -152.866 uV 16:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.192 uVs 16:45:54 Integrated Voltage Measurement... 16:46:03 Voltage Offset Correction: v_off_ini = -141.676 uV, v_off_fin = -119.036 uV 16:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.272 uVs 16:46:03 Integrated Voltage Measurement... 16:46:12 Voltage Offset Correction: v_off_ini = -141.115 uV, v_off_fin = -154.011 uV 16:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.297 uVs 16:46:14 I2X Average and RMS of Measurements VT = -78.259 +- 8.645 uVs I2X = 7.200 +- 0.795 uTm^2 16:46:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:22 Integrated Voltage Measurement... 16:46:31 Voltage Offset Correction: v_off_ini = -143.852 uV, v_off_fin = -160.621 uV 16:46:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.048 uVs 16:46:31 Integrated Voltage Measurement... 16:46:40 Voltage Offset Correction: v_off_ini = -152.833 uV, v_off_fin = -144.291 uV 16:46:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.340 uVs 16:46:40 Integrated Voltage Measurement... 16:46:49 Voltage Offset Correction: v_off_ini = -146.721 uV, v_off_fin = -142.844 uV 16:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.364 uVs 16:46:49 Integrated Voltage Measurement... 16:46:58 Voltage Offset Correction: v_off_ini = -144.606 uV, v_off_fin = -135.517 uV 16:46:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.771 uVs 16:46:58 Integrated Voltage Measurement... 16:47:07 Voltage Offset Correction: v_off_ini = -147.206 uV, v_off_fin = -136.328 uV 16:47:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.931 uVs 16:47:07 Integrated Voltage Measurement... 16:47:16 Voltage Offset Correction: v_off_ini = -128.432 uV, v_off_fin = -134.002 uV 16:47:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.830 uVs 16:47:18 I2Y Average and RMS of Measurements VT = -190.714 +- 5.392 uVs I2Y = -17.546 +- 0.496 uTm^2 16:47:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:32 Integrated Voltage Measurement... 16:47:41 Voltage Offset Correction: v_off_ini = -141.013 uV, v_off_fin = -128.533 uV 16:47:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.859 uVs 16:47:41 Integrated Voltage Measurement... 16:47:50 Voltage Offset Correction: v_off_ini = -129.741 uV, v_off_fin = -114.957 uV 16:47:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.080 uVs 16:47:50 Integrated Voltage Measurement... 16:47:59 Voltage Offset Correction: v_off_ini = -136.913 uV, v_off_fin = -145.345 uV 16:47:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.704 uVs 16:47:59 Integrated Voltage Measurement... 16:48:08 Voltage Offset Correction: v_off_ini = -140.914 uV, v_off_fin = -127.963 uV 16:48:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.841 uVs 16:48:08 Integrated Voltage Measurement... 16:48:17 Voltage Offset Correction: v_off_ini = -123.933 uV, v_off_fin = -127.588 uV 16:48:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.993 uVs 16:48:17 Integrated Voltage Measurement... 16:48:26 Voltage Offset Correction: v_off_ini = -132.425 uV, v_off_fin = -143.066 uV 16:48:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.353 uVs 16:48:31 I1X Average and RMS of Measurements VT = -43.972 +- 2.196 uVs I1X = 8.794 +- 0.439 uTm 16:48:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:37 Integrated Voltage Measurement... 16:48:46 Voltage Offset Correction: v_off_ini = -133.321 uV, v_off_fin = -147.912 uV 16:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.065 uVs 16:48:46 Integrated Voltage Measurement... 16:48:55 Voltage Offset Correction: v_off_ini = -150.404 uV, v_off_fin = -126.562 uV 16:48:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.741 uVs 16:48:55 Integrated Voltage Measurement... 16:49:04 Voltage Offset Correction: v_off_ini = -148.883 uV, v_off_fin = -154.049 uV 16:49:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.275 uVs 16:49:04 Integrated Voltage Measurement... 16:49:13 Voltage Offset Correction: v_off_ini = -146.679 uV, v_off_fin = -124.550 uV 16:49:13 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.074 uVs 16:49:13 Integrated Voltage Measurement... 16:49:22 Voltage Offset Correction: v_off_ini = -144.851 uV, v_off_fin = -156.845 uV 16:49:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -157.647 uVs 16:49:22 Integrated Voltage Measurement... 16:49:31 Voltage Offset Correction: v_off_ini = -128.032 uV, v_off_fin = -114.232 uV 16:49:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.037 uVs 16:49:36 I1Y Average and RMS of Measurements VT = -172.973 +- 3.133 uVs I1Y = -34.594 +- 0.627 uTm 16:49:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:43 Integrated Voltage Measurement... 16:49:52 Voltage Offset Correction: v_off_ini = -115.561 uV, v_off_fin = -133.158 uV 16:49:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -62.962 uVs 16:49:52 Integrated Voltage Measurement... 16:50:01 Voltage Offset Correction: v_off_ini = -126.834 uV, v_off_fin = -138.033 uV 16:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.958 uVs 16:50:01 Integrated Voltage Measurement... 16:50:10 Voltage Offset Correction: v_off_ini = -134.614 uV, v_off_fin = -124.998 uV 16:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.906 uVs 16:50:10 Integrated Voltage Measurement... 16:50:19 Voltage Offset Correction: v_off_ini = -135.718 uV, v_off_fin = -137.918 uV 16:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.313 uVs 16:50:20 Integrated Voltage Measurement... 16:50:29 Voltage Offset Correction: v_off_ini = -146.949 uV, v_off_fin = -135.015 uV 16:50:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.611 uVs 16:50:29 Integrated Voltage Measurement... 16:50:38 Voltage Offset Correction: v_off_ini = -146.082 uV, v_off_fin = -155.167 uV 16:50:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.725 uVs 16:50:40 I2X Average and RMS of Measurements VT = -65.246 +- 1.973 uVs I2X = 6.003 +- 0.181 uTm^2 16:50:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:48 Integrated Voltage Measurement... 16:50:57 Voltage Offset Correction: v_off_ini = -140.693 uV, v_off_fin = -139.208 uV 16:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.630 uVs 16:50:57 Integrated Voltage Measurement... 16:51:06 Voltage Offset Correction: v_off_ini = -143.012 uV, v_off_fin = -140.598 uV 16:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.123 uVs 16:51:06 Integrated Voltage Measurement... 16:51:15 Voltage Offset Correction: v_off_ini = -149.299 uV, v_off_fin = -146.335 uV 16:51:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.965 uVs 16:51:15 Integrated Voltage Measurement... 16:51:24 Voltage Offset Correction: v_off_ini = -135.616 uV, v_off_fin = -148.681 uV 16:51:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.922 uVs 16:51:24 Integrated Voltage Measurement... 16:51:33 Voltage Offset Correction: v_off_ini = -142.763 uV, v_off_fin = -143.592 uV 16:51:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.545 uVs 16:51:33 Integrated Voltage Measurement... 16:51:42 Voltage Offset Correction: v_off_ini = -147.391 uV, v_off_fin = -146.328 uV 16:51:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.884 uVs 16:51:44 I2Y Average and RMS of Measurements VT = -186.511 +- 10.213 uVs I2Y = -17.159 +- 0.940 uTm^2 16:51:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:58 Integrated Voltage Measurement... 16:52:07 Voltage Offset Correction: v_off_ini = -153.395 uV, v_off_fin = -133.344 uV 16:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.641 uVs 16:52:07 Integrated Voltage Measurement... 16:52:16 Voltage Offset Correction: v_off_ini = -131.103 uV, v_off_fin = -119.676 uV 16:52:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.003 uVs 16:52:16 Integrated Voltage Measurement... 16:52:25 Voltage Offset Correction: v_off_ini = -136.548 uV, v_off_fin = -138.908 uV 16:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.730 uVs 16:52:25 Integrated Voltage Measurement... 16:52:34 Voltage Offset Correction: v_off_ini = -128.450 uV, v_off_fin = -130.505 uV 16:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.105 uVs 16:52:34 Integrated Voltage Measurement... 16:52:43 Voltage Offset Correction: v_off_ini = -132.162 uV, v_off_fin = -135.653 uV 16:52:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.433 uVs 16:52:43 Integrated Voltage Measurement... 16:52:52 Voltage Offset Correction: v_off_ini = -138.771 uV, v_off_fin = -128.985 uV 16:52:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.403 uVs 16:52:57 I1X Average and RMS of Measurements VT = -42.553 +- 4.151 uVs I1X = 8.511 +- 0.830 uTm 16:52:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:03 Integrated Voltage Measurement... 16:53:12 Voltage Offset Correction: v_off_ini = -148.537 uV, v_off_fin = -147.937 uV 16:53:12 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -158.265 uVs 16:53:12 Integrated Voltage Measurement... 16:53:21 Voltage Offset Correction: v_off_ini = -135.509 uV, v_off_fin = -122.252 uV 16:53:21 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 171.704 uVs 16:53:21 Integrated Voltage Measurement... 16:53:30 Voltage Offset Correction: v_off_ini = -147.721 uV, v_off_fin = -154.666 uV 16:53:30 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -156.059 uVs 16:53:30 Integrated Voltage Measurement... 16:53:39 Voltage Offset Correction: v_off_ini = -146.474 uV, v_off_fin = -141.666 uV 16:53:39 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 180.110 uVs 16:53:39 Integrated Voltage Measurement... 16:53:48 Voltage Offset Correction: v_off_ini = -130.765 uV, v_off_fin = -153.232 uV 16:53:48 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -159.977 uVs 16:53:48 Integrated Voltage Measurement... 16:53:57 Voltage Offset Correction: v_off_ini = -142.575 uV, v_off_fin = -130.551 uV 16:53:57 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 181.117 uVs 16:54:01 I1Y Average and RMS of Measurements VT = -167.872 +- 2.276 uVs I1Y = -33.567 +- 0.454 uTm 16:54:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:09 Integrated Voltage Measurement... 16:54:18 Voltage Offset Correction: v_off_ini = -118.202 uV, v_off_fin = -121.176 uV 16:54:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -59.137 uVs 16:54:18 Integrated Voltage Measurement... 16:54:27 Voltage Offset Correction: v_off_ini = -132.602 uV, v_off_fin = -141.563 uV 16:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.493 uVs 16:54:27 Integrated Voltage Measurement... 16:54:36 Voltage Offset Correction: v_off_ini = -132.454 uV, v_off_fin = -119.914 uV 16:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.003 uVs 16:54:36 Integrated Voltage Measurement... 16:54:45 Voltage Offset Correction: v_off_ini = -119.095 uV, v_off_fin = -132.883 uV 16:54:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.152 uVs 16:54:45 Integrated Voltage Measurement... 16:54:54 Voltage Offset Correction: v_off_ini = -127.187 uV, v_off_fin = -125.334 uV 16:54:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.965 uVs 16:54:54 Integrated Voltage Measurement... 16:55:03 Voltage Offset Correction: v_off_ini = -119.997 uV, v_off_fin = -125.768 uV 16:55:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.644 uVs 16:55:06 I2X Average and RMS of Measurements VT = -46.899 +- 14.891 uVs I2X = 4.315 +- 1.370 uTm^2 16:55:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:13 Integrated Voltage Measurement... 16:55:22 Voltage Offset Correction: v_off_ini = -123.852 uV, v_off_fin = -114.133 uV 16:55:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.136 uVs 16:55:23 Integrated Voltage Measurement... 16:55:32 Voltage Offset Correction: v_off_ini = -116.176 uV, v_off_fin = -140.670 uV 16:55:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.847 uVs 16:55:32 Integrated Voltage Measurement... 16:55:41 Voltage Offset Correction: v_off_ini = -112.138 uV, v_off_fin = -127.433 uV 16:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.008 uVs 16:55:41 Integrated Voltage Measurement... 16:55:50 Voltage Offset Correction: v_off_ini = -136.583 uV, v_off_fin = -133.313 uV 16:55:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.096 uVs 16:55:50 Integrated Voltage Measurement... 16:55:59 Voltage Offset Correction: v_off_ini = -130.659 uV, v_off_fin = -135.321 uV 16:55:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.814 uVs 16:55:59 Integrated Voltage Measurement... 16:56:08 Voltage Offset Correction: v_off_ini = -131.148 uV, v_off_fin = -139.591 uV 16:56:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.805 uVs 16:56:10 I2Y Average and RMS of Measurements VT = -194.284 +- 2.994 uVs I2Y = -17.874 +- 0.275 uTm^2 16:56:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:24 Integrated Voltage Measurement... 16:56:33 Voltage Offset Correction: v_off_ini = -140.849 uV, v_off_fin = -144.646 uV 16:56:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.003 uVs 16:56:33 Integrated Voltage Measurement... 16:56:42 Voltage Offset Correction: v_off_ini = -133.164 uV, v_off_fin = -131.546 uV 16:56:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.659 uVs 16:56:42 Integrated Voltage Measurement... 16:56:51 Voltage Offset Correction: v_off_ini = -141.567 uV, v_off_fin = -140.086 uV 16:56:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.461 uVs 16:56:51 Integrated Voltage Measurement... 16:57:00 Voltage Offset Correction: v_off_ini = -142.766 uV, v_off_fin = -143.377 uV 16:57:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.506 uVs 16:57:00 Integrated Voltage Measurement... 16:57:09 Voltage Offset Correction: v_off_ini = -133.233 uV, v_off_fin = -141.707 uV 16:57:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.520 uVs 16:57:09 Integrated Voltage Measurement... 16:57:18 Voltage Offset Correction: v_off_ini = -156.372 uV, v_off_fin = -138.444 uV 16:57:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.470 uVs 16:57:22 I1X Average and RMS of Measurements VT = -44.936 +- 5.685 uVs I1X = 8.987 +- 1.137 uTm 16:57:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:29 Integrated Voltage Measurement... 16:57:38 Voltage Offset Correction: v_off_ini = -130.581 uV, v_off_fin = -148.869 uV 16:57:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.355 uVs 16:57:38 Integrated Voltage Measurement... 16:57:47 Voltage Offset Correction: v_off_ini = -150.937 uV, v_off_fin = -143.410 uV 16:57:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.119 uVs 16:57:47 Integrated Voltage Measurement... 16:57:56 Voltage Offset Correction: v_off_ini = -146.776 uV, v_off_fin = -151.056 uV 16:57:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.113 uVs 16:57:56 Integrated Voltage Measurement... 16:58:05 Voltage Offset Correction: v_off_ini = -146.241 uV, v_off_fin = -138.784 uV 16:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.659 uVs 16:58:05 Integrated Voltage Measurement... 16:58:14 Voltage Offset Correction: v_off_ini = -162.004 uV, v_off_fin = -159.764 uV 16:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.609 uVs 16:58:14 Integrated Voltage Measurement... 16:58:23 Voltage Offset Correction: v_off_ini = -163.679 uV, v_off_fin = -136.238 uV 16:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.855 uVs 16:58:27 I1Y Average and RMS of Measurements VT = -160.452 +- 9.795 uVs I1Y = -32.090 +- 1.959 uTm 16:58:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:35 Integrated Voltage Measurement... 16:58:44 Voltage Offset Correction: v_off_ini = -157.280 uV, v_off_fin = -142.976 uV 16:58:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -56.733 uVs 16:58:44 Integrated Voltage Measurement... 16:58:53 Voltage Offset Correction: v_off_ini = -142.407 uV, v_off_fin = -152.841 uV 16:58:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.711 uVs 16:58:53 Integrated Voltage Measurement... 16:59:02 Voltage Offset Correction: v_off_ini = -166.405 uV, v_off_fin = -145.759 uV 16:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.159 uVs 16:59:02 Integrated Voltage Measurement... 16:59:11 Voltage Offset Correction: v_off_ini = -156.065 uV, v_off_fin = -160.107 uV 16:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.035 uVs 16:59:11 Integrated Voltage Measurement... 16:59:20 Voltage Offset Correction: v_off_ini = -142.344 uV, v_off_fin = -132.567 uV 16:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.818 uVs 16:59:20 Integrated Voltage Measurement... 16:59:29 Voltage Offset Correction: v_off_ini = -137.285 uV, v_off_fin = -138.396 uV 16:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.752 uVs 16:59:32 I2X Average and RMS of Measurements VT = -48.368 +- 7.663 uVs I2X = 4.450 +- 0.705 uTm^2 16:59:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:39 Integrated Voltage Measurement... 16:59:48 Voltage Offset Correction: v_off_ini = -124.832 uV, v_off_fin = -116.642 uV 16:59:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.973 uVs 16:59:48 Integrated Voltage Measurement... 16:59:57 Voltage Offset Correction: v_off_ini = -126.151 uV, v_off_fin = -126.779 uV 16:59:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.660 uVs 16:59:57 Integrated Voltage Measurement... 17:00:06 Voltage Offset Correction: v_off_ini = -133.572 uV, v_off_fin = -125.092 uV 17:00:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.410 uVs 17:00:06 Integrated Voltage Measurement... 17:00:15 Voltage Offset Correction: v_off_ini = -137.501 uV, v_off_fin = -129.219 uV 17:00:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.168 uVs 17:00:15 Integrated Voltage Measurement... 17:00:24 Voltage Offset Correction: v_off_ini = -125.970 uV, v_off_fin = -126.896 uV 17:00:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.013 uVs 17:00:25 Integrated Voltage Measurement... 17:00:33 Voltage Offset Correction: v_off_ini = -112.088 uV, v_off_fin = -109.156 uV 17:00:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.054 uVs 17:00:36 I2Y Average and RMS of Measurements VT = -184.380 +- 2.056 uVs I2Y = -16.963 +- 0.189 uTm^2 17:00:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = -125.909 uV, v_off_fin = -121.053 uV 17:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -12.689 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = -109.074 uV, v_off_fin = -100.875 uV 17:01:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.474 uVs 17:01:08 Integrated Voltage Measurement... 17:01:17 Voltage Offset Correction: v_off_ini = -93.096 uV, v_off_fin = -89.394 uV 17:01:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.882 uVs 17:01:17 Integrated Voltage Measurement... 17:01:26 Voltage Offset Correction: v_off_ini = -95.997 uV, v_off_fin = -75.123 uV 17:01:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.678 uVs 17:01:26 Integrated Voltage Measurement... 17:01:35 Voltage Offset Correction: v_off_ini = -89.624 uV, v_off_fin = -82.543 uV 17:01:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.720 uVs 17:01:35 Integrated Voltage Measurement... 17:01:44 Voltage Offset Correction: v_off_ini = -95.679 uV, v_off_fin = -83.548 uV 17:01:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.448 uVs 17:01:48 I1X Average and RMS of Measurements VT = -40.148 +- 13.895 uVs I1X = 8.030 +- 2.779 uTm 17:01:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:55 Integrated Voltage Measurement... 17:02:04 Voltage Offset Correction: v_off_ini = -90.588 uV, v_off_fin = -82.759 uV 17:02:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.507 uVs 17:02:04 Integrated Voltage Measurement... 17:02:13 Voltage Offset Correction: v_off_ini = -95.266 uV, v_off_fin = -75.762 uV 17:02:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.270 uVs 17:02:13 Integrated Voltage Measurement... 17:02:22 Voltage Offset Correction: v_off_ini = -74.993 uV, v_off_fin = -100.798 uV 17:02:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.026 uVs 17:02:22 Integrated Voltage Measurement... 17:02:31 Voltage Offset Correction: v_off_ini = -85.159 uV, v_off_fin = -81.401 uV 17:02:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.986 uVs 17:02:31 Integrated Voltage Measurement... 17:02:40 Voltage Offset Correction: v_off_ini = -78.228 uV, v_off_fin = -96.529 uV 17:02:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.822 uVs 17:02:40 Integrated Voltage Measurement... 17:02:49 Voltage Offset Correction: v_off_ini = -100.129 uV, v_off_fin = -87.745 uV 17:02:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.000 uVs 17:02:53 I1Y Average and RMS of Measurements VT = -159.435 +- 2.223 uVs I1Y = -31.887 +- 0.445 uTm 17:02:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:01 Integrated Voltage Measurement... 17:03:10 Voltage Offset Correction: v_off_ini = -83.647 uV, v_off_fin = -83.949 uV 17:03:10 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -50.022 uVs 17:03:10 Integrated Voltage Measurement... 17:03:19 Voltage Offset Correction: v_off_ini = -93.111 uV, v_off_fin = -109.163 uV 17:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.146 uVs 17:03:19 Integrated Voltage Measurement... 17:03:28 Voltage Offset Correction: v_off_ini = -100.848 uV, v_off_fin = -91.476 uV 17:03:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.079 uVs 17:03:28 Integrated Voltage Measurement... 17:03:37 Voltage Offset Correction: v_off_ini = -81.631 uV, v_off_fin = -109.050 uV 17:03:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.127 uVs 17:03:37 Integrated Voltage Measurement... 17:03:46 Voltage Offset Correction: v_off_ini = -88.330 uV, v_off_fin = -77.787 uV 17:03:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.857 uVs 17:03:46 Integrated Voltage Measurement... 17:03:55 Voltage Offset Correction: v_off_ini = -82.611 uV, v_off_fin = -106.446 uV 17:03:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.657 uVs 17:03:57 I2X Average and RMS of Measurements VT = -45.481 +- 1.769 uVs I2X = 4.184 +- 0.163 uTm^2 17:04:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:05 Integrated Voltage Measurement... 17:04:14 Voltage Offset Correction: v_off_ini = -83.882 uV, v_off_fin = -83.419 uV 17:04:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.527 uVs 17:04:14 Integrated Voltage Measurement... 17:04:23 Voltage Offset Correction: v_off_ini = -93.201 uV, v_off_fin = -88.209 uV 17:04:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.358 uVs 17:04:23 Integrated Voltage Measurement... 17:04:32 Voltage Offset Correction: v_off_ini = -115.064 uV, v_off_fin = -109.958 uV 17:04:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.916 uVs 17:04:32 Integrated Voltage Measurement... 17:04:41 Voltage Offset Correction: v_off_ini = -93.819 uV, v_off_fin = -87.969 uV 17:04:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.932 uVs 17:04:41 Integrated Voltage Measurement... 17:04:50 Voltage Offset Correction: v_off_ini = -98.944 uV, v_off_fin = -107.763 uV 17:04:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.847 uVs 17:04:50 Integrated Voltage Measurement... 17:04:59 Voltage Offset Correction: v_off_ini = -116.298 uV, v_off_fin = -104.828 uV 17:04:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.567 uVs 17:05:01 I2Y Average and RMS of Measurements VT = -180.691 +- 4.417 uVs I2Y = -16.624 +- 0.406 uTm^2 17:05:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:15 Integrated Voltage Measurement... 17:05:24 Voltage Offset Correction: v_off_ini = -135.706 uV, v_off_fin = -115.919 uV 17:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.100 uVs 17:05:24 Integrated Voltage Measurement... 17:05:33 Voltage Offset Correction: v_off_ini = -115.657 uV, v_off_fin = -104.516 uV 17:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.317 uVs 17:05:33 Integrated Voltage Measurement... 17:05:42 Voltage Offset Correction: v_off_ini = -117.510 uV, v_off_fin = -106.391 uV 17:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.457 uVs 17:05:42 Integrated Voltage Measurement... 17:05:51 Voltage Offset Correction: v_off_ini = -102.456 uV, v_off_fin = -101.713 uV 17:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.837 uVs 17:05:51 Integrated Voltage Measurement... 17:06:00 Voltage Offset Correction: v_off_ini = -101.145 uV, v_off_fin = -114.293 uV 17:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.347 uVs 17:06:00 Integrated Voltage Measurement... 17:06:09 Voltage Offset Correction: v_off_ini = -113.040 uV, v_off_fin = -129.912 uV 17:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.491 uVs 17:06:14 I1X Average and RMS of Measurements VT = -41.925 +- 3.592 uVs I1X = 8.385 +- 0.718 uTm 17:06:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:20 Integrated Voltage Measurement... 17:06:29 Voltage Offset Correction: v_off_ini = -120.623 uV, v_off_fin = -120.039 uV 17:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -143.734 uVs 17:06:29 Integrated Voltage Measurement... 17:06:38 Voltage Offset Correction: v_off_ini = -121.570 uV, v_off_fin = -102.873 uV 17:06:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.957 uVs 17:06:38 Integrated Voltage Measurement... 17:06:47 Voltage Offset Correction: v_off_ini = -111.013 uV, v_off_fin = -121.385 uV 17:06:47 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -155.220 uVs 17:06:47 Integrated Voltage Measurement... 17:06:56 Voltage Offset Correction: v_off_ini = -104.147 uV, v_off_fin = -94.729 uV 17:06:56 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 165.198 uVs 17:06:56 Integrated Voltage Measurement... 17:07:05 Voltage Offset Correction: v_off_ini = -109.364 uV, v_off_fin = -124.488 uV 17:07:05 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -150.433 uVs 17:07:05 Integrated Voltage Measurement... 17:07:14 Voltage Offset Correction: v_off_ini = -125.141 uV, v_off_fin = -106.587 uV 17:07:14 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 152.821 uVs 17:07:18 I1Y Average and RMS of Measurements VT = -151.227 +- 7.502 uVs I1Y = -30.241 +- 1.497 uTm 17:07:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:26 Integrated Voltage Measurement... 17:07:35 Voltage Offset Correction: v_off_ini = -92.344 uV, v_off_fin = -90.139 uV 17:07:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -55.652 uVs 17:07:35 Integrated Voltage Measurement... 17:07:44 Voltage Offset Correction: v_off_ini = -107.355 uV, v_off_fin = -109.087 uV 17:07:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.162 uVs 17:07:44 Integrated Voltage Measurement... 17:07:53 Voltage Offset Correction: v_off_ini = -105.985 uV, v_off_fin = -112.610 uV 17:07:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.599 uVs 17:07:53 Integrated Voltage Measurement... 17:08:02 Voltage Offset Correction: v_off_ini = -114.105 uV, v_off_fin = -123.523 uV 17:08:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.391 uVs 17:08:02 Integrated Voltage Measurement... 17:08:11 Voltage Offset Correction: v_off_ini = -110.679 uV, v_off_fin = -103.468 uV 17:08:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.500 uVs 17:08:11 Integrated Voltage Measurement... 17:08:20 Voltage Offset Correction: v_off_ini = -112.083 uV, v_off_fin = -119.199 uV 17:08:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.852 uVs 17:08:23 I2X Average and RMS of Measurements VT = -45.192 +- 3.403 uVs I2X = 4.158 +- 0.313 uTm^2 17:08:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:30 Integrated Voltage Measurement... 17:08:39 Voltage Offset Correction: v_off_ini = -107.770 uV, v_off_fin = -125.214 uV 17:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.464 uVs 17:08:39 Integrated Voltage Measurement... 17:08:48 Voltage Offset Correction: v_off_ini = -114.019 uV, v_off_fin = -111.998 uV 17:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.878 uVs 17:08:48 Integrated Voltage Measurement... 17:08:57 Voltage Offset Correction: v_off_ini = -103.298 uV, v_off_fin = -98.931 uV 17:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.338 uVs 17:08:58 Integrated Voltage Measurement... 17:09:06 Voltage Offset Correction: v_off_ini = -99.820 uV, v_off_fin = -108.750 uV 17:09:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.344 uVs 17:09:07 Integrated Voltage Measurement... 17:09:16 Voltage Offset Correction: v_off_ini = -92.496 uV, v_off_fin = -99.730 uV 17:09:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.877 uVs 17:09:16 Integrated Voltage Measurement... 17:09:25 Voltage Offset Correction: v_off_ini = -87.035 uV, v_off_fin = -98.116 uV 17:09:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.892 uVs 17:09:27 I2Y Average and RMS of Measurements VT = -167.299 +- 7.556 uVs I2Y = -15.391 +- 0.695 uTm^2 17:09:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:41 Integrated Voltage Measurement... 17:09:50 Voltage Offset Correction: v_off_ini = -118.565 uV, v_off_fin = -125.680 uV 17:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -18.273 uVs 17:09:50 Integrated Voltage Measurement... 17:09:59 Voltage Offset Correction: v_off_ini = -124.457 uV, v_off_fin = -111.044 uV 17:09:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.875 uVs 17:09:59 Integrated Voltage Measurement... 17:10:08 Voltage Offset Correction: v_off_ini = -117.042 uV, v_off_fin = -112.779 uV 17:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -16.488 uVs 17:10:08 Integrated Voltage Measurement... 17:10:17 Voltage Offset Correction: v_off_ini = -107.211 uV, v_off_fin = -101.152 uV 17:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.679 uVs 17:10:17 Integrated Voltage Measurement... 17:10:26 Voltage Offset Correction: v_off_ini = -129.371 uV, v_off_fin = -124.337 uV 17:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.998 uVs 17:10:26 Integrated Voltage Measurement... 17:10:35 Voltage Offset Correction: v_off_ini = -114.476 uV, v_off_fin = -107.688 uV 17:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.975 uVs 17:10:39 I1X Average and RMS of Measurements VT = -27.715 +- 7.538 uVs I1X = 5.543 +- 1.508 uTm 17:10:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:46 Integrated Voltage Measurement... 17:10:55 Voltage Offset Correction: v_off_ini = -111.027 uV, v_off_fin = -135.065 uV 17:10:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -147.179 uVs 17:10:55 Integrated Voltage Measurement... 17:11:04 Voltage Offset Correction: v_off_ini = -111.649 uV, v_off_fin = -99.880 uV 17:11:04 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.841 uVs 17:11:04 Integrated Voltage Measurement... 17:11:13 Voltage Offset Correction: v_off_ini = -103.076 uV, v_off_fin = -120.929 uV 17:11:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -152.287 uVs 17:11:13 Integrated Voltage Measurement... 17:11:22 Voltage Offset Correction: v_off_ini = -108.851 uV, v_off_fin = -103.980 uV 17:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 147.007 uVs 17:11:22 Integrated Voltage Measurement... 17:11:31 Voltage Offset Correction: v_off_ini = -107.500 uV, v_off_fin = -125.717 uV 17:11:31 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -151.342 uVs 17:11:31 Integrated Voltage Measurement... 17:11:40 Voltage Offset Correction: v_off_ini = -106.055 uV, v_off_fin = -107.314 uV 17:11:40 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 166.676 uVs 17:11:44 I1Y Average and RMS of Measurements VT = -153.722 +- 3.917 uVs I1Y = -30.741 +- 0.782 uTm 17:11:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:52 Integrated Voltage Measurement... 17:12:01 Voltage Offset Correction: v_off_ini = -98.808 uV, v_off_fin = -87.819 uV 17:12:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -59.020 uVs 17:12:01 Integrated Voltage Measurement... 17:12:10 Voltage Offset Correction: v_off_ini = -108.243 uV, v_off_fin = -112.820 uV 17:12:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 69.307 uVs 17:12:10 Integrated Voltage Measurement... 17:12:19 Voltage Offset Correction: v_off_ini = -97.395 uV, v_off_fin = -92.015 uV 17:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.880 uVs 17:12:19 Integrated Voltage Measurement... 17:12:28 Voltage Offset Correction: v_off_ini = -101.706 uV, v_off_fin = -102.428 uV 17:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.116 uVs 17:12:28 Integrated Voltage Measurement... 17:12:37 Voltage Offset Correction: v_off_ini = -98.713 uV, v_off_fin = -111.116 uV 17:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.062 uVs 17:12:37 Integrated Voltage Measurement... 17:12:46 Voltage Offset Correction: v_off_ini = -112.799 uV, v_off_fin = -133.952 uV 17:12:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.144 uVs 17:12:48 I2X Average and RMS of Measurements VT = -46.255 +- 14.519 uVs I2X = 4.255 +- 1.336 uTm^2 17:12:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:56 Integrated Voltage Measurement... 17:13:05 Voltage Offset Correction: v_off_ini = -103.004 uV, v_off_fin = -96.411 uV 17:13:05 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -154.805 uVs 17:13:05 Integrated Voltage Measurement... 17:13:14 Voltage Offset Correction: v_off_ini = -103.433 uV, v_off_fin = -101.656 uV 17:13:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.167 uVs 17:13:14 Integrated Voltage Measurement... 17:13:23 Voltage Offset Correction: v_off_ini = -104.871 uV, v_off_fin = -103.293 uV 17:13:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.338 uVs 17:13:23 Integrated Voltage Measurement... 17:13:32 Voltage Offset Correction: v_off_ini = -106.954 uV, v_off_fin = -104.245 uV 17:13:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.753 uVs 17:13:32 Integrated Voltage Measurement... 17:13:41 Voltage Offset Correction: v_off_ini = -89.677 uV, v_off_fin = -91.830 uV 17:13:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.171 uVs 17:13:41 Integrated Voltage Measurement... 17:13:50 Voltage Offset Correction: v_off_ini = -88.794 uV, v_off_fin = -88.213 uV 17:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.315 uVs 17:13:52 I2Y Average and RMS of Measurements VT = -170.758 +- 5.344 uVs I2Y = -15.710 +- 0.492 uTm^2 17:14:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:14:06 Integrated Voltage Measurement... 17:14:15 Voltage Offset Correction: v_off_ini = -98.260 uV, v_off_fin = -106.869 uV 17:14:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -16.663 uVs 17:14:15 Integrated Voltage Measurement... 17:14:24 Voltage Offset Correction: v_off_ini = -115.940 uV, v_off_fin = -102.956 uV 17:14:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.709 uVs 17:14:24 Integrated Voltage Measurement... 17:14:33 Voltage Offset Correction: v_off_ini = -93.052 uV, v_off_fin = -83.121 uV 17:14:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.393 uVs 17:14:33 Integrated Voltage Measurement... 17:14:42 Voltage Offset Correction: v_off_ini = -85.933 uV, v_off_fin = -95.418 uV 17:14:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.744 uVs 17:14:42 Integrated Voltage Measurement... 17:14:51 Voltage Offset Correction: v_off_ini = -92.718 uV, v_off_fin = -105.976 uV 17:14:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.704 uVs 17:14:51 Integrated Voltage Measurement... 17:15:00 Voltage Offset Correction: v_off_ini = -92.799 uV, v_off_fin = -90.783 uV 17:15:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.057 uVs 17:15:05 I1X Average and RMS of Measurements VT = -28.212 +- 5.374 uVs I1X = 5.642 +- 1.075 uTm 17:15:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:15:11 Integrated Voltage Measurement... 17:15:20 Voltage Offset Correction: v_off_ini = -112.159 uV, v_off_fin = -129.868 uV 17:15:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.173 uVs 17:15:20 Integrated Voltage Measurement... 17:15:29 Voltage Offset Correction: v_off_ini = -110.837 uV, v_off_fin = -101.623 uV 17:15:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 134.286 uVs 17:15:29 Integrated Voltage Measurement... 17:15:38 Voltage Offset Correction: v_off_ini = -105.230 uV, v_off_fin = -121.476 uV 17:15:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.691 uVs 17:15:38 Integrated Voltage Measurement... 17:15:47 Voltage Offset Correction: v_off_ini = -112.037 uV, v_off_fin = -90.012 uV 17:15:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.852 uVs 17:15:47 Integrated Voltage Measurement... 17:15:56 Voltage Offset Correction: v_off_ini = -102.982 uV, v_off_fin = -115.074 uV 17:15:56 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -144.115 uVs 17:15:56 Integrated Voltage Measurement... 17:16:05 Voltage Offset Correction: v_off_ini = -108.200 uV, v_off_fin = -87.927 uV 17:16:05 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 165.990 uVs 17:16:09 I1Y Average and RMS of Measurements VT = -144.351 +- 8.169 uVs I1Y = -28.868 +- 1.631 uTm 17:16:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:17 Integrated Voltage Measurement... 17:16:26 Voltage Offset Correction: v_off_ini = -107.352 uV, v_off_fin = -90.174 uV 17:16:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -38.129 uVs 17:16:26 Integrated Voltage Measurement... 17:16:35 Voltage Offset Correction: v_off_ini = -96.446 uV, v_off_fin = -106.386 uV 17:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.887 uVs 17:16:35 Integrated Voltage Measurement... 17:16:44 Voltage Offset Correction: v_off_ini = -88.057 uV, v_off_fin = -79.028 uV 17:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.312 uVs 17:16:44 Integrated Voltage Measurement... 17:16:53 Voltage Offset Correction: v_off_ini = -114.124 uV, v_off_fin = -108.497 uV 17:16:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.969 uVs 17:16:53 Integrated Voltage Measurement... 17:17:02 Voltage Offset Correction: v_off_ini = -90.663 uV, v_off_fin = -96.476 uV 17:17:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.101 uVs 17:17:02 Integrated Voltage Measurement... 17:17:11 Voltage Offset Correction: v_off_ini = -109.636 uV, v_off_fin = -116.638 uV 17:17:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.336 uVs 17:17:14 I2X Average and RMS of Measurements VT = -40.456 +- 2.509 uVs I2X = 3.722 +- 0.231 uTm^2 17:17:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:21 Integrated Voltage Measurement... 17:17:30 Voltage Offset Correction: v_off_ini = -101.082 uV, v_off_fin = -108.500 uV 17:17:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.293 uVs 17:17:30 Integrated Voltage Measurement... 17:17:39 Voltage Offset Correction: v_off_ini = -100.044 uV, v_off_fin = -111.541 uV 17:17:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.124 uVs 17:17:39 Integrated Voltage Measurement... 17:17:48 Voltage Offset Correction: v_off_ini = -128.608 uV, v_off_fin = -119.471 uV 17:17:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.555 uVs 17:17:48 Integrated Voltage Measurement... 17:17:57 Voltage Offset Correction: v_off_ini = -133.629 uV, v_off_fin = -116.955 uV 17:17:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.833 uVs 17:17:57 Integrated Voltage Measurement... 17:18:06 Voltage Offset Correction: v_off_ini = -122.851 uV, v_off_fin = -113.652 uV 17:18:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -154.751 uVs 17:18:06 Integrated Voltage Measurement... 17:18:15 Voltage Offset Correction: v_off_ini = -126.549 uV, v_off_fin = -114.341 uV 17:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.747 uVs 17:18:18 I2Y Average and RMS of Measurements VT = -169.551 +- 4.529 uVs I2Y = -15.599 +- 0.417 uTm^2 17:18:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:33 Integrated Voltage Measurement... 17:18:42 Voltage Offset Correction: v_off_ini = -137.936 uV, v_off_fin = -118.374 uV 17:18:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.563 uVs 17:18:42 Integrated Voltage Measurement... 17:18:51 Voltage Offset Correction: v_off_ini = -108.095 uV, v_off_fin = -124.652 uV 17:18:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.780 uVs 17:18:51 Integrated Voltage Measurement... 17:19:00 Voltage Offset Correction: v_off_ini = -119.957 uV, v_off_fin = -112.080 uV 17:19:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.574 uVs 17:19:00 Integrated Voltage Measurement... 17:19:09 Voltage Offset Correction: v_off_ini = -115.745 uV, v_off_fin = -112.562 uV 17:19:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.684 uVs 17:19:09 Integrated Voltage Measurement... 17:19:18 Voltage Offset Correction: v_off_ini = -134.201 uV, v_off_fin = -121.305 uV 17:19:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.752 uVs 17:19:18 Integrated Voltage Measurement... 17:19:27 Voltage Offset Correction: v_off_ini = -115.215 uV, v_off_fin = -115.139 uV 17:19:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.744 uVs 17:19:31 I1X Average and RMS of Measurements VT = -33.850 +- 7.644 uVs I1X = 6.770 +- 1.529 uTm 17:19:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:38 Integrated Voltage Measurement... 17:19:47 Voltage Offset Correction: v_off_ini = -114.388 uV, v_off_fin = -132.672 uV 17:19:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -140.389 uVs 17:19:47 Integrated Voltage Measurement... 17:19:55 Voltage Offset Correction: v_off_ini = -118.877 uV, v_off_fin = -110.609 uV 17:19:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.731 uVs 17:19:56 Integrated Voltage Measurement... 17:20:04 Voltage Offset Correction: v_off_ini = -113.290 uV, v_off_fin = -124.265 uV 17:20:04 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -133.057 uVs 17:20:05 Integrated Voltage Measurement... 17:20:13 Voltage Offset Correction: v_off_ini = -110.887 uV, v_off_fin = -113.125 uV 17:20:13 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 159.183 uVs 17:20:13 Integrated Voltage Measurement... 17:20:22 Voltage Offset Correction: v_off_ini = -120.609 uV, v_off_fin = -127.798 uV 17:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -143.944 uVs 17:20:22 Integrated Voltage Measurement... 17:20:31 Voltage Offset Correction: v_off_ini = -108.838 uV, v_off_fin = -100.605 uV 17:20:31 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 148.539 uVs 17:20:36 I1Y Average and RMS of Measurements VT = -144.474 +- 2.415 uVs I1Y = -28.892 +- 0.481 uTm 17:20:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:43 Integrated Voltage Measurement... 17:20:52 Voltage Offset Correction: v_off_ini = -110.890 uV, v_off_fin = -99.554 uV 17:20:52 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -44.561 uVs 17:20:52 Integrated Voltage Measurement... 17:21:01 Voltage Offset Correction: v_off_ini = -105.030 uV, v_off_fin = -114.517 uV 17:21:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.279 uVs 17:21:01 Integrated Voltage Measurement... 17:21:10 Voltage Offset Correction: v_off_ini = -109.530 uV, v_off_fin = -100.291 uV 17:21:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.124 uVs 17:21:10 Integrated Voltage Measurement... 17:21:19 Voltage Offset Correction: v_off_ini = -121.594 uV, v_off_fin = -124.130 uV 17:21:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.744 uVs 17:21:19 Integrated Voltage Measurement... 17:21:28 Voltage Offset Correction: v_off_ini = -99.318 uV, v_off_fin = -106.082 uV 17:21:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.400 uVs 17:21:28 Integrated Voltage Measurement... 17:21:37 Voltage Offset Correction: v_off_ini = -99.811 uV, v_off_fin = -105.379 uV 17:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.051 uVs 17:21:40 I2X Average and RMS of Measurements VT = -47.193 +- 5.634 uVs I2X = 4.342 +- 0.518 uTm^2 17:21:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:47 Integrated Voltage Measurement... 17:21:56 Voltage Offset Correction: v_off_ini = -106.125 uV, v_off_fin = -91.927 uV 17:21:56 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -167.060 uVs 17:21:56 Integrated Voltage Measurement... 17:22:05 Voltage Offset Correction: v_off_ini = -85.487 uV, v_off_fin = -81.898 uV 17:22:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.278 uVs 17:22:05 Integrated Voltage Measurement... 17:22:14 Voltage Offset Correction: v_off_ini = -85.767 uV, v_off_fin = -86.507 uV 17:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.350 uVs 17:22:14 Integrated Voltage Measurement... 17:22:23 Voltage Offset Correction: v_off_ini = -78.811 uV, v_off_fin = -91.266 uV 17:22:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.632 uVs 17:22:23 Integrated Voltage Measurement... 17:22:32 Voltage Offset Correction: v_off_ini = -91.435 uV, v_off_fin = -87.548 uV 17:22:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.076 uVs 17:22:32 Integrated Voltage Measurement... 17:22:41 Voltage Offset Correction: v_off_ini = -69.630 uV, v_off_fin = -83.490 uV 17:22:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.057 uVs 17:22:44 I2Y Average and RMS of Measurements VT = -164.409 +- 5.912 uVs I2Y = -15.125 +- 0.544 uTm^2 17:22:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:59 Integrated Voltage Measurement... 17:23:08 Voltage Offset Correction: v_off_ini = -83.204 uV, v_off_fin = -80.859 uV 17:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -45.727 uVs 17:23:08 Integrated Voltage Measurement... 17:23:17 Voltage Offset Correction: v_off_ini = -101.437 uV, v_off_fin = -91.138 uV 17:23:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.519 uVs 17:23:17 Integrated Voltage Measurement... 17:23:26 Voltage Offset Correction: v_off_ini = -81.844 uV, v_off_fin = -85.924 uV 17:23:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.502 uVs 17:23:26 Integrated Voltage Measurement... 17:23:35 Voltage Offset Correction: v_off_ini = -79.664 uV, v_off_fin = -76.161 uV 17:23:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.418 uVs 17:23:35 Integrated Voltage Measurement... 17:23:44 Voltage Offset Correction: v_off_ini = -86.490 uV, v_off_fin = -76.915 uV 17:23:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.938 uVs 17:23:44 Integrated Voltage Measurement... 17:23:53 Voltage Offset Correction: v_off_ini = -90.374 uV, v_off_fin = -87.255 uV 17:23:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.724 uVs 17:23:57 I1X Average and RMS of Measurements VT = -35.971 +- 4.074 uVs I1X = 7.194 +- 0.815 uTm 17:24:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:04 Integrated Voltage Measurement... 17:24:13 Voltage Offset Correction: v_off_ini = -94.565 uV, v_off_fin = -102.111 uV 17:24:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -126.443 uVs 17:24:13 Integrated Voltage Measurement... 17:24:22 Voltage Offset Correction: v_off_ini = -83.865 uV, v_off_fin = -64.801 uV 17:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.404 uVs 17:24:22 Integrated Voltage Measurement... 17:24:31 Voltage Offset Correction: v_off_ini = -90.350 uV, v_off_fin = -104.504 uV 17:24:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -142.779 uVs 17:24:31 Integrated Voltage Measurement... 17:24:40 Voltage Offset Correction: v_off_ini = -80.330 uV, v_off_fin = -82.422 uV 17:24:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 162.219 uVs 17:24:40 Integrated Voltage Measurement... 17:24:49 Voltage Offset Correction: v_off_ini = -86.856 uV, v_off_fin = -112.314 uV 17:24:49 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -155.535 uVs 17:24:49 Integrated Voltage Measurement... 17:24:58 Voltage Offset Correction: v_off_ini = -94.522 uV, v_off_fin = -73.922 uV 17:24:58 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 159.743 uVs 17:25:02 I1Y Average and RMS of Measurements VT = -152.187 +- 4.584 uVs I1Y = -30.436 +- 0.913 uTm 17:25:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:09 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = -86.861 uV, v_off_fin = -76.125 uV 17:25:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -37.988 uVs 17:25:18 Integrated Voltage Measurement... 17:25:27 Voltage Offset Correction: v_off_ini = -79.603 uV, v_off_fin = -91.800 uV 17:25:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.655 uVs 17:25:27 Integrated Voltage Measurement... 17:25:36 Voltage Offset Correction: v_off_ini = -79.209 uV, v_off_fin = -69.788 uV 17:25:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.252 uVs 17:25:37 Integrated Voltage Measurement... 17:25:45 Voltage Offset Correction: v_off_ini = -71.845 uV, v_off_fin = -79.803 uV 17:25:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.128 uVs 17:25:46 Integrated Voltage Measurement... 17:25:54 Voltage Offset Correction: v_off_ini = -78.758 uV, v_off_fin = -71.357 uV 17:25:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.927 uVs 17:25:55 Integrated Voltage Measurement... 17:26:04 Voltage Offset Correction: v_off_ini = -67.256 uV, v_off_fin = -77.245 uV 17:26:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.616 uVs 17:26:06 I2X Average and RMS of Measurements VT = -46.761 +- 3.300 uVs I2X = 4.302 +- 0.304 uTm^2 17:26:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:14 Integrated Voltage Measurement... 17:26:23 Voltage Offset Correction: v_off_ini = -78.975 uV, v_off_fin = -93.112 uV 17:26:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.521 uVs 17:26:23 Integrated Voltage Measurement... 17:26:32 Voltage Offset Correction: v_off_ini = -76.727 uV, v_off_fin = -65.818 uV 17:26:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.346 uVs 17:26:32 Integrated Voltage Measurement... 17:26:41 Voltage Offset Correction: v_off_ini = -75.936 uV, v_off_fin = -74.179 uV 17:26:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.928 uVs 17:26:41 Integrated Voltage Measurement... 17:26:50 Voltage Offset Correction: v_off_ini = -66.160 uV, v_off_fin = -83.909 uV 17:26:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 165.814 uVs 17:26:50 Integrated Voltage Measurement... 17:26:59 Voltage Offset Correction: v_off_ini = -70.752 uV, v_off_fin = -89.802 uV 17:26:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.940 uVs 17:26:59 Integrated Voltage Measurement... 17:27:08 Voltage Offset Correction: v_off_ini = -77.133 uV, v_off_fin = -67.017 uV 17:27:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.507 uVs 17:27:10 I2Y Average and RMS of Measurements VT = -168.009 +- 5.115 uVs I2Y = -15.457 +- 0.471 uTm^2 17:27:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:27:27 Integrated Voltage Measurement... 17:27:36 Voltage Offset Correction: v_off_ini = -90.714 uV, v_off_fin = -76.013 uV 17:27:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.445 uVs 17:27:36 Integrated Voltage Measurement... 17:27:45 Voltage Offset Correction: v_off_ini = -72.000 uV, v_off_fin = -67.613 uV 17:27:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.795 uVs 17:27:45 Integrated Voltage Measurement... 17:27:54 Voltage Offset Correction: v_off_ini = -85.195 uV, v_off_fin = -87.804 uV 17:27:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.930 uVs 17:27:54 Integrated Voltage Measurement... 17:28:03 Voltage Offset Correction: v_off_ini = -61.365 uV, v_off_fin = -65.475 uV 17:28:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.597 uVs 17:28:03 Integrated Voltage Measurement... 17:28:12 Voltage Offset Correction: v_off_ini = -86.812 uV, v_off_fin = -82.496 uV 17:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.934 uVs 17:28:12 Integrated Voltage Measurement... 17:28:21 Voltage Offset Correction: v_off_ini = -73.629 uV, v_off_fin = -80.661 uV 17:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 10.456 uVs 17:28:26 I1X Average and RMS of Measurements VT = -27.193 +- 2.712 uVs I1X = 5.439 +- 0.542 uTm 17:28:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:32 Integrated Voltage Measurement... 17:28:41 Voltage Offset Correction: v_off_ini = -84.684 uV, v_off_fin = -96.420 uV 17:28:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.407 uVs 17:28:41 Integrated Voltage Measurement... 17:28:50 Voltage Offset Correction: v_off_ini = -81.296 uV, v_off_fin = -73.674 uV 17:28:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.992 uVs 17:28:50 Integrated Voltage Measurement... 17:28:59 Voltage Offset Correction: v_off_ini = -91.962 uV, v_off_fin = -88.723 uV 17:28:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.910 uVs 17:28:59 Integrated Voltage Measurement... 17:29:08 Voltage Offset Correction: v_off_ini = -89.668 uV, v_off_fin = -94.424 uV 17:29:08 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.144 uVs 17:29:08 Integrated Voltage Measurement... 17:29:17 Voltage Offset Correction: v_off_ini = -90.218 uV, v_off_fin = -106.647 uV 17:29:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.831 uVs 17:29:17 Integrated Voltage Measurement... 17:29:26 Voltage Offset Correction: v_off_ini = -100.336 uV, v_off_fin = -91.528 uV 17:29:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.337 uVs 17:29:30 I1Y Average and RMS of Measurements VT = -170.270 +- 7.355 uVs I1Y = -34.053 +- 1.471 uTm 17:29:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:38 Integrated Voltage Measurement... 17:29:47 Voltage Offset Correction: v_off_ini = -96.060 uV, v_off_fin = -86.362 uV 17:29:47 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -61.369 uVs 17:29:47 Integrated Voltage Measurement... 17:29:56 Voltage Offset Correction: v_off_ini = -100.179 uV, v_off_fin = -101.272 uV 17:29:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.248 uVs 17:29:56 Integrated Voltage Measurement... 17:30:05 Voltage Offset Correction: v_off_ini = -80.954 uV, v_off_fin = -81.478 uV 17:30:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.024 uVs 17:30:05 Integrated Voltage Measurement... 17:30:14 Voltage Offset Correction: v_off_ini = -75.119 uV, v_off_fin = -89.951 uV 17:30:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.887 uVs 17:30:14 Integrated Voltage Measurement... 17:30:23 Voltage Offset Correction: v_off_ini = -73.625 uV, v_off_fin = -75.715 uV 17:30:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.246 uVs 17:30:23 Integrated Voltage Measurement... 17:30:32 Voltage Offset Correction: v_off_ini = -111.937 uV, v_off_fin = -114.266 uV 17:30:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.112 uVs 17:30:35 I2X Average and RMS of Measurements VT = -61.981 +- 3.387 uVs I2X = 5.702 +- 0.312 uTm^2 17:30:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:42 Integrated Voltage Measurement... 17:30:51 Voltage Offset Correction: v_off_ini = -91.364 uV, v_off_fin = -93.860 uV 17:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.326 uVs 17:30:52 Integrated Voltage Measurement... 17:31:00 Voltage Offset Correction: v_off_ini = -79.977 uV, v_off_fin = -86.933 uV 17:31:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.650 uVs 17:31:01 Integrated Voltage Measurement... 17:31:10 Voltage Offset Correction: v_off_ini = -76.116 uV, v_off_fin = -86.743 uV 17:31:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.230 uVs 17:31:10 Integrated Voltage Measurement... 17:31:19 Voltage Offset Correction: v_off_ini = -82.415 uV, v_off_fin = -83.801 uV 17:31:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.211 uVs 17:31:19 Integrated Voltage Measurement... 17:31:28 Voltage Offset Correction: v_off_ini = -79.934 uV, v_off_fin = -81.612 uV 17:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.739 uVs 17:31:28 Integrated Voltage Measurement... 17:31:37 Voltage Offset Correction: v_off_ini = -76.351 uV, v_off_fin = -80.993 uV 17:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.371 uVs 17:31:39 I2Y Average and RMS of Measurements VT = -196.921 +- 4.272 uVs I2Y = -18.117 +- 0.393 uTm^2 17:31:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:31:56 Integrated Voltage Measurement... 17:32:05 Voltage Offset Correction: v_off_ini = -94.953 uV, v_off_fin = -71.677 uV 17:32:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.722 uVs 17:32:05 Integrated Voltage Measurement... 17:32:14 Voltage Offset Correction: v_off_ini = -69.741 uV, v_off_fin = -79.315 uV 17:32:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.409 uVs 17:32:14 Integrated Voltage Measurement... 17:32:23 Voltage Offset Correction: v_off_ini = -81.698 uV, v_off_fin = -80.184 uV 17:32:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.045 uVs 17:32:23 Integrated Voltage Measurement... 17:32:32 Voltage Offset Correction: v_off_ini = -82.314 uV, v_off_fin = -90.227 uV 17:32:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.777 uVs 17:32:32 Integrated Voltage Measurement... 17:32:41 Voltage Offset Correction: v_off_ini = -95.625 uV, v_off_fin = -103.859 uV 17:32:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.230 uVs 17:32:41 Integrated Voltage Measurement... 17:32:50 Voltage Offset Correction: v_off_ini = -85.839 uV, v_off_fin = -81.566 uV 17:32:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 8.092 uVs 17:32:55 I1X Average and RMS of Measurements VT = -31.546 +- 3.460 uVs I1X = 6.309 +- 0.692 uTm 17:32:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:33:01 Integrated Voltage Measurement... 17:33:10 Voltage Offset Correction: v_off_ini = -83.656 uV, v_off_fin = -98.973 uV 17:33:10 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.581 uVs 17:33:10 Integrated Voltage Measurement... 17:33:19 Voltage Offset Correction: v_off_ini = -90.416 uV, v_off_fin = -76.239 uV 17:33:19 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 189.611 uVs 17:33:19 Integrated Voltage Measurement... 17:33:28 Voltage Offset Correction: v_off_ini = -81.329 uV, v_off_fin = -102.603 uV 17:33:28 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -181.316 uVs 17:33:28 Integrated Voltage Measurement... 17:33:37 Voltage Offset Correction: v_off_ini = -64.760 uV, v_off_fin = -61.059 uV 17:33:37 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 185.917 uVs 17:33:37 Integrated Voltage Measurement... 17:33:46 Voltage Offset Correction: v_off_ini = -85.158 uV, v_off_fin = -111.336 uV 17:33:46 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -169.213 uVs 17:33:46 Integrated Voltage Measurement... 17:33:55 Voltage Offset Correction: v_off_ini = -111.477 uV, v_off_fin = -85.327 uV 17:33:55 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 190.868 uVs 17:34:00 I1Y Average and RMS of Measurements VT = -183.417 +- 2.680 uVs I1Y = -36.676 +- 0.537 uTm 17:34:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:34:07 Integrated Voltage Measurement... 17:34:16 Voltage Offset Correction: v_off_ini = -89.675 uV, v_off_fin = -84.473 uV 17:34:16 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -47.250 uVs 17:34:16 Integrated Voltage Measurement... 17:34:25 Voltage Offset Correction: v_off_ini = -90.965 uV, v_off_fin = -125.080 uV 17:34:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.172 uVs 17:34:25 Integrated Voltage Measurement... 17:34:34 Voltage Offset Correction: v_off_ini = -112.697 uV, v_off_fin = -87.966 uV 17:34:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.781 uVs 17:34:34 Integrated Voltage Measurement... 17:34:43 Voltage Offset Correction: v_off_ini = -92.919 uV, v_off_fin = -106.682 uV 17:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.330 uVs 17:34:44 Integrated Voltage Measurement... 17:34:52 Voltage Offset Correction: v_off_ini = -94.762 uV, v_off_fin = -96.182 uV 17:34:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.424 uVs 17:34:53 Integrated Voltage Measurement... 17:35:02 Voltage Offset Correction: v_off_ini = -104.380 uV, v_off_fin = -103.646 uV 17:35:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.841 uVs 17:35:04 I2X Average and RMS of Measurements VT = -53.300 +- 2.733 uVs I2X = 4.903 +- 0.251 uTm^2 17:35:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:12 Integrated Voltage Measurement... 17:35:21 Voltage Offset Correction: v_off_ini = -95.425 uV, v_off_fin = -93.161 uV 17:35:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.356 uVs 17:35:21 Integrated Voltage Measurement... 17:35:30 Voltage Offset Correction: v_off_ini = -102.964 uV, v_off_fin = -93.547 uV 17:35:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.757 uVs 17:35:30 Integrated Voltage Measurement... 17:35:39 Voltage Offset Correction: v_off_ini = -92.002 uV, v_off_fin = -84.311 uV 17:35:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.953 uVs 17:35:39 Integrated Voltage Measurement... 17:35:48 Voltage Offset Correction: v_off_ini = -94.528 uV, v_off_fin = -96.669 uV 17:35:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.301 uVs 17:35:48 Integrated Voltage Measurement... 17:35:57 Voltage Offset Correction: v_off_ini = -99.550 uV, v_off_fin = -102.653 uV 17:35:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.811 uVs 17:35:57 Integrated Voltage Measurement... 17:36:06 Voltage Offset Correction: v_off_ini = -97.518 uV, v_off_fin = -78.302 uV 17:36:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.332 uVs 17:36:08 I2Y Average and RMS of Measurements VT = -198.085 +- 6.111 uVs I2Y = -18.224 +- 0.562 uTm^2 17:36:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:36:26 Integrated Voltage Measurement... 17:36:35 Voltage Offset Correction: v_off_ini = -94.976 uV, v_off_fin = -96.052 uV 17:36:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.634 uVs 17:36:35 Integrated Voltage Measurement... 17:36:44 Voltage Offset Correction: v_off_ini = -93.570 uV, v_off_fin = -83.299 uV 17:36:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.762 uVs 17:36:44 Integrated Voltage Measurement... 17:36:53 Voltage Offset Correction: v_off_ini = -88.799 uV, v_off_fin = -104.516 uV 17:36:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.813 uVs 17:36:53 Integrated Voltage Measurement... 17:37:02 Voltage Offset Correction: v_off_ini = -89.513 uV, v_off_fin = -85.791 uV 17:37:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.204 uVs 17:37:02 Integrated Voltage Measurement... 17:37:11 Voltage Offset Correction: v_off_ini = -90.502 uV, v_off_fin = -95.970 uV 17:37:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.553 uVs 17:37:11 Integrated Voltage Measurement... 17:37:20 Voltage Offset Correction: v_off_ini = -73.420 uV, v_off_fin = -70.033 uV 17:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.849 uVs 17:37:24 I1X Average and RMS of Measurements VT = -42.136 +- 3.945 uVs I1X = 8.427 +- 0.789 uTm 17:37:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:37:31 Integrated Voltage Measurement... 17:37:40 Voltage Offset Correction: v_off_ini = -89.946 uV, v_off_fin = -93.417 uV 17:37:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.897 uVs 17:37:40 Integrated Voltage Measurement... 17:37:49 Voltage Offset Correction: v_off_ini = -90.131 uV, v_off_fin = -71.554 uV 17:37:49 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.837 uVs 17:37:49 Integrated Voltage Measurement... 17:37:57 Voltage Offset Correction: v_off_ini = -88.914 uV, v_off_fin = -105.703 uV 17:37:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.945 uVs 17:37:58 Integrated Voltage Measurement... 17:38:06 Voltage Offset Correction: v_off_ini = -87.200 uV, v_off_fin = -67.444 uV 17:38:06 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.539 uVs 17:38:07 Integrated Voltage Measurement... 17:38:15 Voltage Offset Correction: v_off_ini = -79.405 uV, v_off_fin = -95.835 uV 17:38:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.800 uVs 17:38:15 Integrated Voltage Measurement... 17:38:24 Voltage Offset Correction: v_off_ini = -89.886 uV, v_off_fin = -68.419 uV 17:38:24 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.399 uVs 17:38:29 I1Y Average and RMS of Measurements VT = -203.736 +- 8.985 uVs I1Y = -40.745 +- 1.797 uTm 17:38:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:36 Integrated Voltage Measurement... 17:38:45 Voltage Offset Correction: v_off_ini = -73.052 uV, v_off_fin = -68.449 uV 17:38:45 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -44.847 uVs 17:38:45 Integrated Voltage Measurement... 17:38:54 Voltage Offset Correction: v_off_ini = -69.392 uV, v_off_fin = -80.506 uV 17:38:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.300 uVs 17:38:54 Integrated Voltage Measurement... 17:39:03 Voltage Offset Correction: v_off_ini = -80.444 uV, v_off_fin = -66.685 uV 17:39:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.943 uVs 17:39:03 Integrated Voltage Measurement... 17:39:12 Voltage Offset Correction: v_off_ini = -64.500 uV, v_off_fin = -77.184 uV 17:39:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.426 uVs 17:39:12 Integrated Voltage Measurement... 17:39:21 Voltage Offset Correction: v_off_ini = -50.888 uV, v_off_fin = -67.276 uV 17:39:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.704 uVs 17:39:22 Integrated Voltage Measurement... 17:39:30 Voltage Offset Correction: v_off_ini = -68.150 uV, v_off_fin = -73.093 uV 17:39:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.217 uVs 17:39:33 I2X Average and RMS of Measurements VT = -61.406 +- 11.584 uVs I2X = 5.649 +- 1.066 uTm^2 17:39:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:41 Integrated Voltage Measurement... 17:39:50 Voltage Offset Correction: v_off_ini = -77.600 uV, v_off_fin = -91.521 uV 17:39:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.002 uVs 17:39:50 Integrated Voltage Measurement... 17:39:59 Voltage Offset Correction: v_off_ini = -83.637 uV, v_off_fin = -93.635 uV 17:39:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.944 uVs 17:39:59 Integrated Voltage Measurement... 17:40:08 Voltage Offset Correction: v_off_ini = -82.878 uV, v_off_fin = -80.908 uV 17:40:08 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -206.737 uVs 17:40:08 Integrated Voltage Measurement... 17:40:17 Voltage Offset Correction: v_off_ini = -75.316 uV, v_off_fin = -87.604 uV 17:40:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 209.376 uVs 17:40:17 Integrated Voltage Measurement... 17:40:26 Voltage Offset Correction: v_off_ini = -91.830 uV, v_off_fin = -75.858 uV 17:40:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.462 uVs 17:40:26 Integrated Voltage Measurement... 17:40:35 Voltage Offset Correction: v_off_ini = -82.845 uV, v_off_fin = -88.865 uV 17:40:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.899 uVs 17:40:37 I2Y Average and RMS of Measurements VT = -216.403 +- 5.923 uVs I2Y = -19.908 +- 0.546 uTm^2 17:40:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:54 Integrated Voltage Measurement... 17:41:03 Voltage Offset Correction: v_off_ini = -102.074 uV, v_off_fin = -100.241 uV 17:41:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.072 uVs 17:41:03 Integrated Voltage Measurement... 17:41:12 Voltage Offset Correction: v_off_ini = -99.337 uV, v_off_fin = -97.341 uV 17:41:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.075 uVs 17:41:12 Integrated Voltage Measurement... 17:41:21 Voltage Offset Correction: v_off_ini = -96.102 uV, v_off_fin = -107.291 uV 17:41:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.061 uVs 17:41:21 Integrated Voltage Measurement... 17:41:30 Voltage Offset Correction: v_off_ini = -108.351 uV, v_off_fin = -94.530 uV 17:41:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.815 uVs 17:41:30 Integrated Voltage Measurement... 17:41:39 Voltage Offset Correction: v_off_ini = -97.714 uV, v_off_fin = -99.312 uV 17:41:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.518 uVs 17:41:39 Integrated Voltage Measurement... 17:41:48 Voltage Offset Correction: v_off_ini = -94.241 uV, v_off_fin = -99.589 uV 17:41:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.616 uVs 17:41:53 I1X Average and RMS of Measurements VT = -44.693 +- 3.456 uVs I1X = 8.939 +- 0.691 uTm 17:41:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:59 Integrated Voltage Measurement... 17:42:08 Voltage Offset Correction: v_off_ini = -104.862 uV, v_off_fin = -102.795 uV 17:42:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.266 uVs 17:42:08 Integrated Voltage Measurement... 17:42:17 Voltage Offset Correction: v_off_ini = -94.658 uV, v_off_fin = -81.279 uV 17:42:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.935 uVs 17:42:17 Integrated Voltage Measurement... 17:42:26 Voltage Offset Correction: v_off_ini = -105.553 uV, v_off_fin = -125.389 uV 17:42:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.684 uVs 17:42:26 Integrated Voltage Measurement... 17:42:35 Voltage Offset Correction: v_off_ini = -106.884 uV, v_off_fin = -104.339 uV 17:42:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.668 uVs 17:42:35 Integrated Voltage Measurement... 17:42:44 Voltage Offset Correction: v_off_ini = -105.843 uV, v_off_fin = -125.420 uV 17:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.961 uVs 17:42:44 Integrated Voltage Measurement... 17:42:53 Voltage Offset Correction: v_off_ini = -107.353 uV, v_off_fin = -102.411 uV 17:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.977 uVs 17:42:57 I1Y Average and RMS of Measurements VT = -217.082 +- 3.635 uVs I1Y = -43.416 +- 0.728 uTm 17:43:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:05 Integrated Voltage Measurement... 17:43:14 Voltage Offset Correction: v_off_ini = -112.345 uV, v_off_fin = -108.011 uV 17:43:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -82.015 uVs 17:43:14 Integrated Voltage Measurement... 17:43:23 Voltage Offset Correction: v_off_ini = -118.780 uV, v_off_fin = -132.602 uV 17:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.248 uVs 17:43:23 Integrated Voltage Measurement... 17:43:32 Voltage Offset Correction: v_off_ini = -117.284 uV, v_off_fin = -106.993 uV 17:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.904 uVs 17:43:32 Integrated Voltage Measurement... 17:43:41 Voltage Offset Correction: v_off_ini = -126.755 uV, v_off_fin = -126.589 uV 17:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.739 uVs 17:43:41 Integrated Voltage Measurement... 17:43:50 Voltage Offset Correction: v_off_ini = -118.804 uV, v_off_fin = -103.505 uV 17:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.914 uVs 17:43:50 Integrated Voltage Measurement... 17:43:59 Voltage Offset Correction: v_off_ini = -118.415 uV, v_off_fin = -112.415 uV 17:43:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.906 uVs 17:44:02 I2X Average and RMS of Measurements VT = -79.288 +- 11.402 uVs I2X = 7.294 +- 1.049 uTm^2 17:44:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:09 Integrated Voltage Measurement... 17:44:18 Voltage Offset Correction: v_off_ini = -103.590 uV, v_off_fin = -114.022 uV 17:44:18 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -245.617 uVs 17:44:18 Integrated Voltage Measurement... 17:44:27 Voltage Offset Correction: v_off_ini = -103.507 uV, v_off_fin = -111.983 uV 17:44:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 232.788 uVs 17:44:27 Integrated Voltage Measurement... 17:44:36 Voltage Offset Correction: v_off_ini = -98.266 uV, v_off_fin = -84.612 uV 17:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.805 uVs 17:44:36 Integrated Voltage Measurement... 17:44:45 Voltage Offset Correction: v_off_ini = -105.675 uV, v_off_fin = -82.404 uV 17:44:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 228.686 uVs 17:44:45 Integrated Voltage Measurement... 17:44:54 Voltage Offset Correction: v_off_ini = -95.996 uV, v_off_fin = -102.920 uV 17:44:54 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -246.108 uVs 17:44:54 Integrated Voltage Measurement... 17:45:03 Voltage Offset Correction: v_off_ini = -97.337 uV, v_off_fin = -110.990 uV 17:45:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 258.583 uVs 17:45:06 I2Y Average and RMS of Measurements VT = -239.264 +- 10.655 uVs I2Y = -22.010 +- 0.980 uTm^2 17:45:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:23 Integrated Voltage Measurement... 17:45:32 Voltage Offset Correction: v_off_ini = -102.910 uV, v_off_fin = -98.312 uV 17:45:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.221 uVs 17:45:32 Integrated Voltage Measurement... 17:45:41 Voltage Offset Correction: v_off_ini = -75.128 uV, v_off_fin = -83.147 uV 17:45:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.826 uVs 17:45:41 Integrated Voltage Measurement... 17:45:50 Voltage Offset Correction: v_off_ini = -86.685 uV, v_off_fin = -98.828 uV 17:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.698 uVs 17:45:50 Integrated Voltage Measurement... 17:45:59 Voltage Offset Correction: v_off_ini = -88.711 uV, v_off_fin = -85.959 uV 17:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.855 uVs 17:45:59 Integrated Voltage Measurement... 17:46:08 Voltage Offset Correction: v_off_ini = -78.731 uV, v_off_fin = -85.928 uV 17:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.288 uVs 17:46:08 Integrated Voltage Measurement... 17:46:17 Voltage Offset Correction: v_off_ini = -85.332 uV, v_off_fin = -79.496 uV 17:46:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.044 uVs 17:46:21 I1X Average and RMS of Measurements VT = -48.989 +- 4.652 uVs I1X = 9.798 +- 0.930 uTm 17:46:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:28 Integrated Voltage Measurement... 17:46:37 Voltage Offset Correction: v_off_ini = -87.643 uV, v_off_fin = -97.791 uV 17:46:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -220.534 uVs 17:46:37 Integrated Voltage Measurement... 17:46:46 Voltage Offset Correction: v_off_ini = -92.980 uV, v_off_fin = -77.821 uV 17:46:46 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.733 uVs 17:46:46 Integrated Voltage Measurement... 17:46:55 Voltage Offset Correction: v_off_ini = -74.668 uV, v_off_fin = -84.239 uV 17:46:55 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -236.683 uVs 17:46:55 Integrated Voltage Measurement... 17:47:04 Voltage Offset Correction: v_off_ini = -91.972 uV, v_off_fin = -64.657 uV 17:47:04 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 239.539 uVs 17:47:04 Integrated Voltage Measurement... 17:47:13 Voltage Offset Correction: v_off_ini = -87.135 uV, v_off_fin = -90.974 uV 17:47:13 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -203.095 uVs 17:47:13 Integrated Voltage Measurement... 17:47:22 Voltage Offset Correction: v_off_ini = -91.821 uV, v_off_fin = -64.370 uV 17:47:22 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 237.165 uVs 17:47:26 I1Y Average and RMS of Measurements VT = -228.625 +- 7.374 uVs I1Y = -45.719 +- 1.474 uTm 17:47:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:47:34 Integrated Voltage Measurement... 17:47:43 Voltage Offset Correction: v_off_ini = -82.842 uV, v_off_fin = -80.702 uV 17:47:43 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -79.030 uVs 17:47:43 Integrated Voltage Measurement... 17:47:52 Voltage Offset Correction: v_off_ini = -83.387 uV, v_off_fin = -92.073 uV 17:47:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.028 uVs 17:47:52 Integrated Voltage Measurement... 17:48:01 Voltage Offset Correction: v_off_ini = -77.095 uV, v_off_fin = -79.456 uV 17:48:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.695 uVs 17:48:01 Integrated Voltage Measurement... 17:48:10 Voltage Offset Correction: v_off_ini = -67.565 uV, v_off_fin = -67.725 uV 17:48:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.030 uVs 17:48:10 Integrated Voltage Measurement... 17:48:19 Voltage Offset Correction: v_off_ini = -63.783 uV, v_off_fin = -60.523 uV 17:48:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.080 uVs 17:48:19 Integrated Voltage Measurement... 17:48:28 Voltage Offset Correction: v_off_ini = -72.111 uV, v_off_fin = -82.155 uV 17:48:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.814 uVs 17:48:30 I2X Average and RMS of Measurements VT = -70.779 +- 4.834 uVs I2X = 6.512 +- 0.445 uTm^2 17:48:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:48:38 Integrated Voltage Measurement... 17:48:47 Voltage Offset Correction: v_off_ini = -65.510 uV, v_off_fin = -69.623 uV 17:48:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.220 uVs 17:48:47 Integrated Voltage Measurement... 17:48:56 Voltage Offset Correction: v_off_ini = -61.323 uV, v_off_fin = -61.491 uV 17:48:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.549 uVs 17:48:56 Integrated Voltage Measurement... 17:49:05 Voltage Offset Correction: v_off_ini = -70.858 uV, v_off_fin = -62.379 uV 17:49:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.420 uVs 17:49:05 Integrated Voltage Measurement... 17:49:14 Voltage Offset Correction: v_off_ini = -68.480 uV, v_off_fin = -78.344 uV 17:49:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 242.152 uVs 17:49:14 Integrated Voltage Measurement... 17:49:23 Voltage Offset Correction: v_off_ini = -62.784 uV, v_off_fin = -70.441 uV 17:49:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.527 uVs 17:49:23 Integrated Voltage Measurement... 17:49:32 Voltage Offset Correction: v_off_ini = -67.911 uV, v_off_fin = -69.345 uV 17:49:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.685 uVs 17:49:35 I2Y Average and RMS of Measurements VT = -240.759 +- 0.346 uVs I2Y = -22.149 +- 0.032 uTm^2 17:49:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:49:50 Integrated Voltage Measurement... 17:49:59 Voltage Offset Correction: v_off_ini = -66.478 uV, v_off_fin = -57.096 uV 17:49:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.373 uVs 17:49:59 Integrated Voltage Measurement... 17:50:08 Voltage Offset Correction: v_off_ini = -67.372 uV, v_off_fin = -52.253 uV 17:50:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.119 uVs 17:50:08 Integrated Voltage Measurement... 17:50:17 Voltage Offset Correction: v_off_ini = -53.469 uV, v_off_fin = -60.762 uV 17:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.210 uVs 17:50:17 Integrated Voltage Measurement... 17:50:26 Voltage Offset Correction: v_off_ini = -52.724 uV, v_off_fin = -47.110 uV 17:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.240 uVs 17:50:26 Integrated Voltage Measurement... 17:50:35 Voltage Offset Correction: v_off_ini = -51.262 uV, v_off_fin = -60.198 uV 17:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.574 uVs 17:50:35 Integrated Voltage Measurement... 17:50:44 Voltage Offset Correction: v_off_ini = -49.329 uV, v_off_fin = -50.578 uV 17:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.285 uVs 17:50:48 I1X Average and RMS of Measurements VT = -56.800 +- 9.183 uVs I1X = 11.360 +- 1.837 uTm 17:50:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:55 Integrated Voltage Measurement... 17:51:04 Voltage Offset Correction: v_off_ini = -61.802 uV, v_off_fin = -79.708 uV 17:51:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.385 uVs 17:51:04 Integrated Voltage Measurement... 17:51:13 Voltage Offset Correction: v_off_ini = -45.425 uV, v_off_fin = -35.201 uV 17:51:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 244.094 uVs 17:51:13 Integrated Voltage Measurement... 17:51:22 Voltage Offset Correction: v_off_ini = -44.114 uV, v_off_fin = -67.668 uV 17:51:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.024 uVs 17:51:22 Integrated Voltage Measurement... 17:51:31 Voltage Offset Correction: v_off_ini = -55.329 uV, v_off_fin = -58.506 uV 17:51:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.073 uVs 17:51:31 Integrated Voltage Measurement... 17:51:40 Voltage Offset Correction: v_off_ini = -70.757 uV, v_off_fin = -87.313 uV 17:51:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.759 uVs 17:51:40 Integrated Voltage Measurement... 17:51:49 Voltage Offset Correction: v_off_ini = -56.315 uV, v_off_fin = -63.232 uV 17:51:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.799 uVs 17:51:53 I1Y Average and RMS of Measurements VT = -235.522 +- 5.495 uVs I1Y = -47.102 +- 1.098 uTm 17:51:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:52:01 Integrated Voltage Measurement... 17:52:10 Voltage Offset Correction: v_off_ini = -55.473 uV, v_off_fin = -56.566 uV 17:52:10 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -110.207 uVs 17:52:10 Integrated Voltage Measurement... 17:52:19 Voltage Offset Correction: v_off_ini = -63.225 uV, v_off_fin = -63.668 uV 17:52:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.488 uVs 17:52:19 Integrated Voltage Measurement... 17:52:28 Voltage Offset Correction: v_off_ini = -62.740 uV, v_off_fin = -56.013 uV 17:52:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.998 uVs 17:52:28 Integrated Voltage Measurement... 17:52:37 Voltage Offset Correction: v_off_ini = -68.048 uV, v_off_fin = -67.414 uV 17:52:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.324 uVs 17:52:37 Integrated Voltage Measurement... 17:52:46 Voltage Offset Correction: v_off_ini = -85.185 uV, v_off_fin = -69.196 uV 17:52:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.651 uVs 17:52:46 Integrated Voltage Measurement... 17:52:55 Voltage Offset Correction: v_off_ini = -73.491 uV, v_off_fin = -73.783 uV 17:52:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.828 uVs 17:52:57 I2X Average and RMS of Measurements VT = -79.249 +- 3.303 uVs I2X = 7.291 +- 0.303 uTm^2 17:53:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:53:05 Integrated Voltage Measurement... 17:53:14 Voltage Offset Correction: v_off_ini = -74.910 uV, v_off_fin = -93.937 uV 17:53:14 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -258.562 uVs 17:53:14 Integrated Voltage Measurement... 17:53:23 Voltage Offset Correction: v_off_ini = -90.599 uV, v_off_fin = -78.937 uV 17:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.099 uVs 17:53:23 Integrated Voltage Measurement... 17:53:32 Voltage Offset Correction: v_off_ini = -73.495 uV, v_off_fin = -90.269 uV 17:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.484 uVs 17:53:32 Integrated Voltage Measurement... 17:53:41 Voltage Offset Correction: v_off_ini = -87.876 uV, v_off_fin = -93.065 uV 17:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.294 uVs 17:53:41 Integrated Voltage Measurement... 17:53:50 Voltage Offset Correction: v_off_ini = -97.222 uV, v_off_fin = -83.754 uV 17:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.807 uVs 17:53:50 Integrated Voltage Measurement... 17:53:59 Voltage Offset Correction: v_off_ini = -76.616 uV, v_off_fin = -72.426 uV 17:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.376 uVs 17:54:02 I2Y Average and RMS of Measurements VT = -247.270 +- 3.141 uVs I2Y = -22.748 +- 0.289 uTm^2 17:54:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm