SLAC Magnetic Measurements Date: 04-22-2025 Time: 14:53:28 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE-SXPS_16348 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 5 Measurement Device: Operator: YL Comment: Tuning 14:53:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:38 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:53:39 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:53:41 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:53:42 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:53:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:58 Integrated Voltage Measurement... 14:54:07 Voltage Offset Correction: v_off_ini = -291.545 uV, v_off_fin = -293.402 uV 14:54:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.564 uVs 14:54:07 Integrated Voltage Measurement... 14:54:16 Voltage Offset Correction: v_off_ini = -294.832 uV, v_off_fin = -283.536 uV 14:54:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.551 uVs 14:54:16 Integrated Voltage Measurement... 14:54:25 Voltage Offset Correction: v_off_ini = -281.658 uV, v_off_fin = -292.678 uV 14:54:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.288 uVs 14:54:25 Integrated Voltage Measurement... 14:54:34 Voltage Offset Correction: v_off_ini = -277.157 uV, v_off_fin = -270.700 uV 14:54:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.712 uVs 14:54:34 Integrated Voltage Measurement... 14:54:43 Voltage Offset Correction: v_off_ini = -273.746 uV, v_off_fin = -288.521 uV 14:54:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.866 uVs 14:54:43 Integrated Voltage Measurement... 14:54:52 Voltage Offset Correction: v_off_ini = -285.580 uV, v_off_fin = -276.231 uV 14:54:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.497 uVs 14:54:56 I1X Average and RMS of Measurements VT = -73.080 +- 6.180 uVs I1X = 14.616 +- 1.236 uTm 14:54:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:03 Integrated Voltage Measurement... 14:55:12 Voltage Offset Correction: v_off_ini = -269.382 uV, v_off_fin = -289.150 uV 14:55:12 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -220.508 uVs 14:55:12 Integrated Voltage Measurement... 14:55:21 Voltage Offset Correction: v_off_ini = -272.581 uV, v_off_fin = -262.044 uV 14:55:21 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 226.937 uVs 14:55:21 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = -286.491 uV, v_off_fin = -288.807 uV 14:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.108 uVs 14:55:30 Integrated Voltage Measurement... 14:55:39 Voltage Offset Correction: v_off_ini = -261.360 uV, v_off_fin = -245.320 uV 14:55:39 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 227.824 uVs 14:55:39 Integrated Voltage Measurement... 14:55:48 Voltage Offset Correction: v_off_ini = -266.423 uV, v_off_fin = -270.904 uV 14:55:48 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -202.745 uVs 14:55:48 Integrated Voltage Measurement... 14:55:57 Voltage Offset Correction: v_off_ini = -256.484 uV, v_off_fin = -241.865 uV 14:55:57 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 220.078 uVs 14:56:01 I1Y Average and RMS of Measurements VT = -218.367 +- 5.152 uVs I1Y = -43.665 +- 1.030 uTm 14:56:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:09 Integrated Voltage Measurement... 14:56:18 Voltage Offset Correction: v_off_ini = -227.824 uV, v_off_fin = -227.579 uV 14:56:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.023 uVs 14:56:18 Integrated Voltage Measurement... 14:56:27 Voltage Offset Correction: v_off_ini = -224.642 uV, v_off_fin = -248.120 uV 14:56:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.850 uVs 14:56:27 Integrated Voltage Measurement... 14:56:36 Voltage Offset Correction: v_off_ini = -226.564 uV, v_off_fin = -217.740 uV 14:56:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.022 uVs 14:56:36 Integrated Voltage Measurement... 14:56:45 Voltage Offset Correction: v_off_ini = -245.381 uV, v_off_fin = -251.404 uV 14:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.448 uVs 14:56:45 Integrated Voltage Measurement... 14:56:54 Voltage Offset Correction: v_off_ini = -237.701 uV, v_off_fin = -234.394 uV 14:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.293 uVs 14:56:54 Integrated Voltage Measurement... 14:57:03 Voltage Offset Correction: v_off_ini = -239.382 uV, v_off_fin = -240.982 uV 14:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.557 uVs 14:57:05 I2X Average and RMS of Measurements VT = -86.199 +- 10.713 uVs I2X = 7.930 +- 0.986 uTm^2 14:57:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:13 Integrated Voltage Measurement... 14:57:22 Voltage Offset Correction: v_off_ini = -231.861 uV, v_off_fin = -232.324 uV 14:57:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.132 uVs 14:57:22 Integrated Voltage Measurement... 14:57:31 Voltage Offset Correction: v_off_ini = -237.770 uV, v_off_fin = -228.006 uV 14:57:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.355 uVs 14:57:31 Integrated Voltage Measurement... 14:57:40 Voltage Offset Correction: v_off_ini = -238.623 uV, v_off_fin = -234.931 uV 14:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.662 uVs 14:57:40 Integrated Voltage Measurement... 14:57:49 Voltage Offset Correction: v_off_ini = -228.122 uV, v_off_fin = -238.215 uV 14:57:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.219 uVs 14:57:49 Integrated Voltage Measurement... 14:57:58 Voltage Offset Correction: v_off_ini = -247.494 uV, v_off_fin = -243.530 uV 14:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.665 uVs 14:57:58 Integrated Voltage Measurement... 14:58:07 Voltage Offset Correction: v_off_ini = -265.569 uV, v_off_fin = -241.244 uV 14:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.051 uVs 14:58:10 I2Y Average and RMS of Measurements VT = -210.347 +- 12.703 uVs I2Y = -19.352 +- 1.169 uTm^2 14:58:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:24 Integrated Voltage Measurement... 14:58:33 Voltage Offset Correction: v_off_ini = -226.010 uV, v_off_fin = -233.939 uV 14:58:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.825 uVs 14:58:33 Integrated Voltage Measurement... 14:58:42 Voltage Offset Correction: v_off_ini = -231.864 uV, v_off_fin = -240.244 uV 14:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.401 uVs 14:58:42 Integrated Voltage Measurement... 14:58:51 Voltage Offset Correction: v_off_ini = -238.953 uV, v_off_fin = -238.434 uV 14:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.989 uVs 14:58:51 Integrated Voltage Measurement... 14:59:00 Voltage Offset Correction: v_off_ini = -221.298 uV, v_off_fin = -235.609 uV 14:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.317 uVs 14:59:00 Integrated Voltage Measurement... 14:59:09 Voltage Offset Correction: v_off_ini = -241.977 uV, v_off_fin = -251.470 uV 14:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.643 uVs 14:59:09 Integrated Voltage Measurement... 14:59:18 Voltage Offset Correction: v_off_ini = -240.749 uV, v_off_fin = -255.478 uV 14:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.836 uVs 14:59:22 I1X Average and RMS of Measurements VT = -66.168 +- 8.054 uVs I1X = 13.234 +- 1.611 uTm 14:59:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:29 Integrated Voltage Measurement... 14:59:38 Voltage Offset Correction: v_off_ini = -243.412 uV, v_off_fin = -256.073 uV 14:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.332 uVs 14:59:38 Integrated Voltage Measurement... 14:59:47 Voltage Offset Correction: v_off_ini = -258.428 uV, v_off_fin = -236.029 uV 14:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.138 uVs 14:59:47 Integrated Voltage Measurement... 14:59:56 Voltage Offset Correction: v_off_ini = -250.820 uV, v_off_fin = -257.484 uV 14:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.285 uVs 14:59:56 Integrated Voltage Measurement... 15:00:05 Voltage Offset Correction: v_off_ini = -249.701 uV, v_off_fin = -239.980 uV 15:00:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.992 uVs 15:00:05 Integrated Voltage Measurement... 15:00:14 Voltage Offset Correction: v_off_ini = -247.629 uV, v_off_fin = -247.760 uV 15:00:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.145 uVs 15:00:14 Integrated Voltage Measurement... 15:00:23 Voltage Offset Correction: v_off_ini = -233.437 uV, v_off_fin = -231.288 uV 15:00:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.829 uVs 15:00:27 I1Y Average and RMS of Measurements VT = -190.287 +- 4.082 uVs I1Y = -38.056 +- 0.818 uTm 15:00:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:35 Integrated Voltage Measurement... 15:00:44 Voltage Offset Correction: v_off_ini = -234.303 uV, v_off_fin = -240.071 uV 15:00:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -67.568 uVs 15:00:44 Integrated Voltage Measurement... 15:00:53 Voltage Offset Correction: v_off_ini = -256.466 uV, v_off_fin = -252.699 uV 15:00:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.765 uVs 15:00:53 Integrated Voltage Measurement... 15:01:02 Voltage Offset Correction: v_off_ini = -248.029 uV, v_off_fin = -234.838 uV 15:01:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.255 uVs 15:01:02 Integrated Voltage Measurement... 15:01:11 Voltage Offset Correction: v_off_ini = -247.414 uV, v_off_fin = -247.416 uV 15:01:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.650 uVs 15:01:11 Integrated Voltage Measurement... 15:01:20 Voltage Offset Correction: v_off_ini = -239.199 uV, v_off_fin = -244.324 uV 15:01:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.435 uVs 15:01:20 Integrated Voltage Measurement... 15:01:29 Voltage Offset Correction: v_off_ini = -259.957 uV, v_off_fin = -257.526 uV 15:01:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.511 uVs 15:01:31 I2X Average and RMS of Measurements VT = -79.197 +- 7.289 uVs I2X = 7.286 +- 0.671 uTm^2 15:01:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:39 Integrated Voltage Measurement... 15:01:48 Voltage Offset Correction: v_off_ini = -255.655 uV, v_off_fin = -252.656 uV 15:01:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.940 uVs 15:01:48 Integrated Voltage Measurement... 15:01:57 Voltage Offset Correction: v_off_ini = -247.683 uV, v_off_fin = -248.463 uV 15:01:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.408 uVs 15:01:57 Integrated Voltage Measurement... 15:02:06 Voltage Offset Correction: v_off_ini = -242.200 uV, v_off_fin = -248.841 uV 15:02:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -213.832 uVs 15:02:06 Integrated Voltage Measurement... 15:02:15 Voltage Offset Correction: v_off_ini = -242.090 uV, v_off_fin = -243.257 uV 15:02:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.414 uVs 15:02:15 Integrated Voltage Measurement... 15:02:24 Voltage Offset Correction: v_off_ini = -256.255 uV, v_off_fin = -249.590 uV 15:02:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.684 uVs 15:02:24 Integrated Voltage Measurement... 15:02:33 Voltage Offset Correction: v_off_ini = -255.951 uV, v_off_fin = -253.703 uV 15:02:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.838 uVs 15:02:36 I2Y Average and RMS of Measurements VT = -195.353 +- 7.846 uVs I2Y = -17.973 +- 0.722 uTm^2 15:02:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:50 Integrated Voltage Measurement... 15:02:59 Voltage Offset Correction: v_off_ini = -261.875 uV, v_off_fin = -265.527 uV 15:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.484 uVs 15:02:59 Integrated Voltage Measurement... 15:03:08 Voltage Offset Correction: v_off_ini = -257.211 uV, v_off_fin = -250.090 uV 15:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.125 uVs 15:03:08 Integrated Voltage Measurement... 15:03:17 Voltage Offset Correction: v_off_ini = -257.433 uV, v_off_fin = -263.498 uV 15:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.613 uVs 15:03:17 Integrated Voltage Measurement... 15:03:26 Voltage Offset Correction: v_off_ini = -248.062 uV, v_off_fin = -240.407 uV 15:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.337 uVs 15:03:26 Integrated Voltage Measurement... 15:03:35 Voltage Offset Correction: v_off_ini = -244.671 uV, v_off_fin = -257.017 uV 15:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.195 uVs 15:03:35 Integrated Voltage Measurement... 15:03:44 Voltage Offset Correction: v_off_ini = -258.876 uV, v_off_fin = -242.468 uV 15:03:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.842 uVs 15:03:48 I1X Average and RMS of Measurements VT = -57.266 +- 1.741 uVs I1X = 11.453 +- 0.348 uTm 15:03:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:55 Integrated Voltage Measurement... 15:04:04 Voltage Offset Correction: v_off_ini = -252.507 uV, v_off_fin = -265.974 uV 15:04:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -177.142 uVs 15:04:04 Integrated Voltage Measurement... 15:04:13 Voltage Offset Correction: v_off_ini = -248.673 uV, v_off_fin = -250.306 uV 15:04:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.981 uVs 15:04:13 Integrated Voltage Measurement... 15:04:22 Voltage Offset Correction: v_off_ini = -254.031 uV, v_off_fin = -261.753 uV 15:04:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.426 uVs 15:04:22 Integrated Voltage Measurement... 15:04:31 Voltage Offset Correction: v_off_ini = -242.506 uV, v_off_fin = -234.900 uV 15:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.713 uVs 15:04:31 Integrated Voltage Measurement... 15:04:40 Voltage Offset Correction: v_off_ini = -251.741 uV, v_off_fin = -256.092 uV 15:04:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.843 uVs 15:04:40 Integrated Voltage Measurement... 15:04:49 Voltage Offset Correction: v_off_ini = -240.446 uV, v_off_fin = -228.418 uV 15:04:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.745 uVs 15:04:53 I1Y Average and RMS of Measurements VT = -178.475 +- 8.983 uVs I1Y = -35.695 +- 1.796 uTm 15:04:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:01 Integrated Voltage Measurement... 15:05:10 Voltage Offset Correction: v_off_ini = -223.908 uV, v_off_fin = -222.123 uV 15:05:10 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -92.749 uVs 15:05:10 Integrated Voltage Measurement... 15:05:19 Voltage Offset Correction: v_off_ini = -238.659 uV, v_off_fin = -234.177 uV 15:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.348 uVs 15:05:19 Integrated Voltage Measurement... 15:05:28 Voltage Offset Correction: v_off_ini = -234.409 uV, v_off_fin = -215.007 uV 15:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.066 uVs 15:05:28 Integrated Voltage Measurement... 15:05:37 Voltage Offset Correction: v_off_ini = -234.051 uV, v_off_fin = -243.340 uV 15:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.401 uVs 15:05:37 Integrated Voltage Measurement... 15:05:46 Voltage Offset Correction: v_off_ini = -244.659 uV, v_off_fin = -218.193 uV 15:05:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.746 uVs 15:05:46 Integrated Voltage Measurement... 15:05:55 Voltage Offset Correction: v_off_ini = -230.985 uV, v_off_fin = -226.401 uV 15:05:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.552 uVs 15:05:57 I2X Average and RMS of Measurements VT = -72.310 +- 12.197 uVs I2X = 6.652 +- 1.122 uTm^2 15:06:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:05 Integrated Voltage Measurement... 15:06:14 Voltage Offset Correction: v_off_ini = -224.649 uV, v_off_fin = -218.421 uV 15:06:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.181 uVs 15:06:14 Integrated Voltage Measurement... 15:06:23 Voltage Offset Correction: v_off_ini = -224.186 uV, v_off_fin = -202.604 uV 15:06:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.142 uVs 15:06:23 Integrated Voltage Measurement... 15:06:32 Voltage Offset Correction: v_off_ini = -204.210 uV, v_off_fin = -223.290 uV 15:06:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.150 uVs 15:06:32 Integrated Voltage Measurement... 15:06:41 Voltage Offset Correction: v_off_ini = -217.147 uV, v_off_fin = -209.762 uV 15:06:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.628 uVs 15:06:41 Integrated Voltage Measurement... 15:06:50 Voltage Offset Correction: v_off_ini = -214.057 uV, v_off_fin = -226.494 uV 15:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.676 uVs 15:06:50 Integrated Voltage Measurement... 15:06:59 Voltage Offset Correction: v_off_ini = -210.100 uV, v_off_fin = -216.353 uV 15:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.870 uVs 15:07:02 I2Y Average and RMS of Measurements VT = -190.108 +- 4.944 uVs I2Y = -17.490 +- 0.455 uTm^2 15:07:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:16 Integrated Voltage Measurement... 15:07:25 Voltage Offset Correction: v_off_ini = -210.527 uV, v_off_fin = -212.973 uV 15:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.885 uVs 15:07:25 Integrated Voltage Measurement... 15:07:34 Voltage Offset Correction: v_off_ini = -202.875 uV, v_off_fin = -205.239 uV 15:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.376 uVs 15:07:34 Integrated Voltage Measurement... 15:07:43 Voltage Offset Correction: v_off_ini = -199.719 uV, v_off_fin = -213.222 uV 15:07:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.150 uVs 15:07:43 Integrated Voltage Measurement... 15:07:52 Voltage Offset Correction: v_off_ini = -208.934 uV, v_off_fin = -199.780 uV 15:07:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.440 uVs 15:07:52 Integrated Voltage Measurement... 15:08:01 Voltage Offset Correction: v_off_ini = -202.400 uV, v_off_fin = -201.642 uV 15:08:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.155 uVs 15:08:01 Integrated Voltage Measurement... 15:08:10 Voltage Offset Correction: v_off_ini = -194.365 uV, v_off_fin = -198.457 uV 15:08:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.714 uVs 15:08:14 I1X Average and RMS of Measurements VT = -43.953 +- 5.719 uVs I1X = 8.791 +- 1.144 uTm 15:08:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = -192.319 uV, v_off_fin = -223.778 uV 15:08:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.453 uVs 15:08:30 Integrated Voltage Measurement... 15:08:39 Voltage Offset Correction: v_off_ini = -186.360 uV, v_off_fin = -178.401 uV 15:08:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.237 uVs 15:08:39 Integrated Voltage Measurement... 15:08:48 Voltage Offset Correction: v_off_ini = -207.486 uV, v_off_fin = -212.600 uV 15:08:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.512 uVs 15:08:48 Integrated Voltage Measurement... 15:08:57 Voltage Offset Correction: v_off_ini = -198.960 uV, v_off_fin = -177.706 uV 15:08:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.721 uVs 15:08:57 Integrated Voltage Measurement... 15:09:06 Voltage Offset Correction: v_off_ini = -200.777 uV, v_off_fin = -196.863 uV 15:09:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.214 uVs 15:09:06 Integrated Voltage Measurement... 15:09:15 Voltage Offset Correction: v_off_ini = -182.793 uV, v_off_fin = -187.250 uV 15:09:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.008 uVs 15:09:19 I1Y Average and RMS of Measurements VT = -167.024 +- 14.414 uVs I1Y = -33.404 +- 2.882 uTm 15:09:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = -177.842 uV, v_off_fin = -192.731 uV 15:09:36 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -68.351 uVs 15:09:36 Integrated Voltage Measurement... 15:09:45 Voltage Offset Correction: v_off_ini = -188.329 uV, v_off_fin = -210.080 uV 15:09:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.300 uVs 15:09:45 Integrated Voltage Measurement... 15:09:54 Voltage Offset Correction: v_off_ini = -199.829 uV, v_off_fin = -186.350 uV 15:09:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.008 uVs 15:09:54 Integrated Voltage Measurement... 15:10:03 Voltage Offset Correction: v_off_ini = -189.130 uV, v_off_fin = -223.031 uV 15:10:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.423 uVs 15:10:03 Integrated Voltage Measurement... 15:10:12 Voltage Offset Correction: v_off_ini = -211.909 uV, v_off_fin = -200.368 uV 15:10:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.295 uVs 15:10:12 Integrated Voltage Measurement... 15:10:21 Voltage Offset Correction: v_off_ini = -215.374 uV, v_off_fin = -232.172 uV 15:10:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.927 uVs 15:10:23 I2X Average and RMS of Measurements VT = -57.217 +- 10.905 uVs I2X = 5.264 +- 1.003 uTm^2 15:10:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:31 Integrated Voltage Measurement... 15:10:40 Voltage Offset Correction: v_off_ini = -216.166 uV, v_off_fin = -234.195 uV 15:10:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.999 uVs 15:10:40 Integrated Voltage Measurement... 15:10:49 Voltage Offset Correction: v_off_ini = -220.871 uV, v_off_fin = -213.644 uV 15:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.254 uVs 15:10:49 Integrated Voltage Measurement... 15:10:58 Voltage Offset Correction: v_off_ini = -216.813 uV, v_off_fin = -212.027 uV 15:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.159 uVs 15:10:58 Integrated Voltage Measurement... 15:11:07 Voltage Offset Correction: v_off_ini = -222.520 uV, v_off_fin = -217.771 uV 15:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.806 uVs 15:11:07 Integrated Voltage Measurement... 15:11:16 Voltage Offset Correction: v_off_ini = -218.066 uV, v_off_fin = -211.316 uV 15:11:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.487 uVs 15:11:16 Integrated Voltage Measurement... 15:11:25 Voltage Offset Correction: v_off_ini = -235.506 uV, v_off_fin = -221.795 uV 15:11:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.966 uVs 15:11:28 I2Y Average and RMS of Measurements VT = -170.945 +- 5.564 uVs I2Y = -15.727 +- 0.512 uTm^2 15:11:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:42 Integrated Voltage Measurement... 15:11:51 Voltage Offset Correction: v_off_ini = -235.506 uV, v_off_fin = -215.397 uV 15:11:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.298 uVs 15:11:51 Integrated Voltage Measurement... 15:12:00 Voltage Offset Correction: v_off_ini = -213.532 uV, v_off_fin = -218.284 uV 15:12:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.136 uVs 15:12:00 Integrated Voltage Measurement... 15:12:09 Voltage Offset Correction: v_off_ini = -230.595 uV, v_off_fin = -223.360 uV 15:12:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.202 uVs 15:12:09 Integrated Voltage Measurement... 15:12:18 Voltage Offset Correction: v_off_ini = -215.974 uV, v_off_fin = -203.624 uV 15:12:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.409 uVs 15:12:18 Integrated Voltage Measurement... 15:12:27 Voltage Offset Correction: v_off_ini = -207.416 uV, v_off_fin = -219.927 uV 15:12:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.167 uVs 15:12:27 Integrated Voltage Measurement... 15:12:36 Voltage Offset Correction: v_off_ini = -217.761 uV, v_off_fin = -207.223 uV 15:12:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.859 uVs 15:12:40 I1X Average and RMS of Measurements VT = -37.345 +- 7.365 uVs I1X = 7.469 +- 1.473 uTm 15:12:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:47 Integrated Voltage Measurement... 15:12:56 Voltage Offset Correction: v_off_ini = -217.435 uV, v_off_fin = -225.640 uV 15:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -165.896 uVs 15:12:56 Integrated Voltage Measurement... 15:13:05 Voltage Offset Correction: v_off_ini = -212.270 uV, v_off_fin = -196.272 uV 15:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.429 uVs 15:13:05 Integrated Voltage Measurement... 15:13:14 Voltage Offset Correction: v_off_ini = -230.759 uV, v_off_fin = -236.048 uV 15:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.177 uVs 15:13:14 Integrated Voltage Measurement... 15:13:23 Voltage Offset Correction: v_off_ini = -207.871 uV, v_off_fin = -193.739 uV 15:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.296 uVs 15:13:23 Integrated Voltage Measurement... 15:13:32 Voltage Offset Correction: v_off_ini = -192.416 uV, v_off_fin = -204.803 uV 15:13:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.589 uVs 15:13:32 Integrated Voltage Measurement... 15:13:41 Voltage Offset Correction: v_off_ini = -197.348 uV, v_off_fin = -187.941 uV 15:13:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 152.090 uVs 15:13:45 I1Y Average and RMS of Measurements VT = -158.746 +- 0.789 uVs I1Y = -31.749 +- 0.159 uTm 15:13:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:53 Integrated Voltage Measurement... 15:14:02 Voltage Offset Correction: v_off_ini = -186.995 uV, v_off_fin = -180.814 uV 15:14:02 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -60.566 uVs 15:14:02 Integrated Voltage Measurement... 15:14:11 Voltage Offset Correction: v_off_ini = -197.104 uV, v_off_fin = -199.066 uV 15:14:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.396 uVs 15:14:11 Integrated Voltage Measurement... 15:14:20 Voltage Offset Correction: v_off_ini = -210.247 uV, v_off_fin = -187.225 uV 15:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.371 uVs 15:14:20 Integrated Voltage Measurement... 15:14:29 Voltage Offset Correction: v_off_ini = -187.347 uV, v_off_fin = -204.311 uV 15:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.963 uVs 15:14:29 Integrated Voltage Measurement... 15:14:38 Voltage Offset Correction: v_off_ini = -206.197 uV, v_off_fin = -186.831 uV 15:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.972 uVs 15:14:38 Integrated Voltage Measurement... 15:14:47 Voltage Offset Correction: v_off_ini = -197.197 uV, v_off_fin = -206.997 uV 15:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.385 uVs 15:14:49 I2X Average and RMS of Measurements VT = -58.775 +- 7.149 uVs I2X = 5.407 +- 0.658 uTm^2 15:14:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:57 Integrated Voltage Measurement... 15:15:06 Voltage Offset Correction: v_off_ini = -180.413 uV, v_off_fin = -202.698 uV 15:15:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.368 uVs 15:15:06 Integrated Voltage Measurement... 15:15:15 Voltage Offset Correction: v_off_ini = -200.574 uV, v_off_fin = -179.735 uV 15:15:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 146.614 uVs 15:15:15 Integrated Voltage Measurement... 15:15:24 Voltage Offset Correction: v_off_ini = -198.389 uV, v_off_fin = -198.738 uV 15:15:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.620 uVs 15:15:24 Integrated Voltage Measurement... 15:15:33 Voltage Offset Correction: v_off_ini = -201.690 uV, v_off_fin = -200.243 uV 15:15:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.915 uVs 15:15:33 Integrated Voltage Measurement... 15:15:42 Voltage Offset Correction: v_off_ini = -182.477 uV, v_off_fin = -188.788 uV 15:15:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.716 uVs 15:15:42 Integrated Voltage Measurement... 15:15:51 Voltage Offset Correction: v_off_ini = -190.273 uV, v_off_fin = -186.438 uV 15:15:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.955 uVs 15:15:54 I2Y Average and RMS of Measurements VT = -165.531 +- 5.781 uVs I2Y = -15.229 +- 0.532 uTm^2 15:16:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:08 Integrated Voltage Measurement... 15:16:17 Voltage Offset Correction: v_off_ini = -185.382 uV, v_off_fin = -185.427 uV 15:16:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.067 uVs 15:16:17 Integrated Voltage Measurement... 15:16:26 Voltage Offset Correction: v_off_ini = -186.207 uV, v_off_fin = -181.135 uV 15:16:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.976 uVs 15:16:26 Integrated Voltage Measurement... 15:16:35 Voltage Offset Correction: v_off_ini = -208.806 uV, v_off_fin = -200.766 uV 15:16:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.965 uVs 15:16:35 Integrated Voltage Measurement... 15:16:44 Voltage Offset Correction: v_off_ini = -200.664 uV, v_off_fin = -177.794 uV 15:16:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.275 uVs 15:16:44 Integrated Voltage Measurement... 15:16:53 Voltage Offset Correction: v_off_ini = -189.003 uV, v_off_fin = -189.794 uV 15:16:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.779 uVs 15:16:53 Integrated Voltage Measurement... 15:17:02 Voltage Offset Correction: v_off_ini = -185.450 uV, v_off_fin = -187.216 uV 15:17:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.514 uVs 15:17:06 I1X Average and RMS of Measurements VT = -39.596 +- 5.981 uVs I1X = 7.919 +- 1.196 uTm 15:17:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:13 Integrated Voltage Measurement... 15:17:22 Voltage Offset Correction: v_off_ini = -191.496 uV, v_off_fin = -196.631 uV 15:17:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -136.539 uVs 15:17:22 Integrated Voltage Measurement... 15:17:31 Voltage Offset Correction: v_off_ini = -196.765 uV, v_off_fin = -173.235 uV 15:17:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.898 uVs 15:17:31 Integrated Voltage Measurement... 15:17:40 Voltage Offset Correction: v_off_ini = -182.217 uV, v_off_fin = -189.525 uV 15:17:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -137.334 uVs 15:17:40 Integrated Voltage Measurement... 15:17:49 Voltage Offset Correction: v_off_ini = -185.037 uV, v_off_fin = -179.695 uV 15:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.969 uVs 15:17:49 Integrated Voltage Measurement... 15:17:58 Voltage Offset Correction: v_off_ini = -174.558 uV, v_off_fin = -185.931 uV 15:17:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.176 uVs 15:17:58 Integrated Voltage Measurement... 15:18:07 Voltage Offset Correction: v_off_ini = -175.416 uV, v_off_fin = -176.472 uV 15:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 148.592 uVs 15:18:11 I1Y Average and RMS of Measurements VT = -143.585 +- 0.849 uVs I1Y = -28.718 +- 0.171 uTm 15:18:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:19 Integrated Voltage Measurement... 15:18:28 Voltage Offset Correction: v_off_ini = -163.699 uV, v_off_fin = -186.120 uV 15:18:28 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -83.284 uVs 15:18:28 Integrated Voltage Measurement... 15:18:37 Voltage Offset Correction: v_off_ini = -198.075 uV, v_off_fin = -200.793 uV 15:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.198 uVs 15:18:37 Integrated Voltage Measurement... 15:18:46 Voltage Offset Correction: v_off_ini = -192.170 uV, v_off_fin = -186.421 uV 15:18:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.420 uVs 15:18:46 Integrated Voltage Measurement... 15:18:55 Voltage Offset Correction: v_off_ini = -187.133 uV, v_off_fin = -204.104 uV 15:18:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.192 uVs 15:18:55 Integrated Voltage Measurement... 15:19:04 Voltage Offset Correction: v_off_ini = -190.216 uV, v_off_fin = -172.527 uV 15:19:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.077 uVs 15:19:04 Integrated Voltage Measurement... 15:19:13 Voltage Offset Correction: v_off_ini = -181.087 uV, v_off_fin = -211.701 uV 15:19:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.451 uVs 15:19:15 I2X Average and RMS of Measurements VT = -61.604 +- 11.247 uVs I2X = 5.667 +- 1.034 uTm^2 15:19:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:23 Integrated Voltage Measurement... 15:19:32 Voltage Offset Correction: v_off_ini = -182.460 uV, v_off_fin = -188.320 uV 15:19:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.276 uVs 15:19:32 Integrated Voltage Measurement... 15:19:41 Voltage Offset Correction: v_off_ini = -186.594 uV, v_off_fin = -199.419 uV 15:19:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.184 uVs 15:19:41 Integrated Voltage Measurement... 15:19:50 Voltage Offset Correction: v_off_ini = -203.925 uV, v_off_fin = -196.856 uV 15:19:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.762 uVs 15:19:50 Integrated Voltage Measurement... 15:19:59 Voltage Offset Correction: v_off_ini = -191.398 uV, v_off_fin = -185.150 uV 15:19:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 167.629 uVs 15:19:59 Integrated Voltage Measurement... 15:20:08 Voltage Offset Correction: v_off_ini = -190.080 uV, v_off_fin = -183.045 uV 15:20:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.391 uVs 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = -182.055 uV, v_off_fin = -181.481 uV 15:20:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.788 uVs 15:20:20 I2Y Average and RMS of Measurements VT = -170.005 +- 5.608 uVs I2Y = -15.640 +- 0.516 uTm^2 15:20:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:33 Integrated Voltage Measurement... 15:20:42 Voltage Offset Correction: v_off_ini = -189.117 uV, v_off_fin = -175.611 uV 15:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.645 uVs 15:20:42 Integrated Voltage Measurement... 15:20:51 Voltage Offset Correction: v_off_ini = -191.051 uV, v_off_fin = -188.256 uV 15:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.690 uVs 15:20:52 Integrated Voltage Measurement... 15:21:00 Voltage Offset Correction: v_off_ini = -188.184 uV, v_off_fin = -198.753 uV 15:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.110 uVs 15:21:01 Integrated Voltage Measurement... 15:21:09 Voltage Offset Correction: v_off_ini = -194.436 uV, v_off_fin = -189.633 uV 15:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.523 uVs 15:21:10 Integrated Voltage Measurement... 15:21:18 Voltage Offset Correction: v_off_ini = -213.297 uV, v_off_fin = -196.105 uV 15:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.818 uVs 15:21:19 Integrated Voltage Measurement... 15:21:27 Voltage Offset Correction: v_off_ini = -201.405 uV, v_off_fin = -192.800 uV 15:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.963 uVs 15:21:32 I1X Average and RMS of Measurements VT = -46.791 +- 2.472 uVs I1X = 9.358 +- 0.494 uTm 15:21:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:39 Integrated Voltage Measurement... 15:21:47 Voltage Offset Correction: v_off_ini = -207.277 uV, v_off_fin = -204.089 uV 15:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -145.676 uVs 15:21:48 Integrated Voltage Measurement... 15:21:56 Voltage Offset Correction: v_off_ini = -199.995 uV, v_off_fin = -196.114 uV 15:21:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.312 uVs 15:21:57 Integrated Voltage Measurement... 15:22:05 Voltage Offset Correction: v_off_ini = -198.211 uV, v_off_fin = -214.477 uV 15:22:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -131.494 uVs 15:22:06 Integrated Voltage Measurement... 15:22:14 Voltage Offset Correction: v_off_ini = -206.056 uV, v_off_fin = -195.581 uV 15:22:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.724 uVs 15:22:15 Integrated Voltage Measurement... 15:22:23 Voltage Offset Correction: v_off_ini = -201.351 uV, v_off_fin = -215.910 uV 15:22:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.146 uVs 15:22:23 Integrated Voltage Measurement... 15:22:32 Voltage Offset Correction: v_off_ini = -211.854 uV, v_off_fin = -201.157 uV 15:22:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 138.078 uVs 15:22:37 I1Y Average and RMS of Measurements VT = -141.738 +- 4.384 uVs I1Y = -28.348 +- 0.877 uTm 15:22:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:44 Integrated Voltage Measurement... 15:22:53 Voltage Offset Correction: v_off_ini = -218.107 uV, v_off_fin = -193.333 uV 15:22:53 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -63.215 uVs 15:22:53 Integrated Voltage Measurement... 15:23:02 Voltage Offset Correction: v_off_ini = -202.474 uV, v_off_fin = -203.497 uV 15:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.716 uVs 15:23:02 Integrated Voltage Measurement... 15:23:11 Voltage Offset Correction: v_off_ini = -206.361 uV, v_off_fin = -192.208 uV 15:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.057 uVs 15:23:11 Integrated Voltage Measurement... 15:23:20 Voltage Offset Correction: v_off_ini = -202.692 uV, v_off_fin = -211.684 uV 15:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.748 uVs 15:23:21 Integrated Voltage Measurement... 15:23:30 Voltage Offset Correction: v_off_ini = -195.549 uV, v_off_fin = -188.336 uV 15:23:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.262 uVs 15:23:30 Integrated Voltage Measurement... 15:23:39 Voltage Offset Correction: v_off_ini = -212.698 uV, v_off_fin = -217.719 uV 15:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.190 uVs 15:23:41 I2X Average and RMS of Measurements VT = -60.365 +- 7.259 uVs I2X = 5.553 +- 0.668 uTm^2 15:23:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:49 Integrated Voltage Measurement... 15:23:58 Voltage Offset Correction: v_off_ini = -204.559 uV, v_off_fin = -199.817 uV 15:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -140.372 uVs 15:23:58 Integrated Voltage Measurement... 15:24:07 Voltage Offset Correction: v_off_ini = -192.610 uV, v_off_fin = -188.413 uV 15:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.457 uVs 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = -198.708 uV, v_off_fin = -185.424 uV 15:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -155.623 uVs 15:24:16 Integrated Voltage Measurement... 15:24:25 Voltage Offset Correction: v_off_ini = -185.353 uV, v_off_fin = -178.846 uV 15:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.607 uVs 15:24:25 Integrated Voltage Measurement... 15:24:34 Voltage Offset Correction: v_off_ini = -171.347 uV, v_off_fin = -183.385 uV 15:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.662 uVs 15:24:34 Integrated Voltage Measurement... 15:24:43 Voltage Offset Correction: v_off_ini = -182.037 uV, v_off_fin = -183.398 uV 15:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 144.581 uVs 15:24:45 I2Y Average and RMS of Measurements VT = -155.217 +- 5.200 uVs I2Y = -14.280 +- 0.478 uTm^2 15:24:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:59 Integrated Voltage Measurement... 15:25:08 Voltage Offset Correction: v_off_ini = -179.927 uV, v_off_fin = -177.481 uV 15:25:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.760 uVs 15:25:08 Integrated Voltage Measurement... 15:25:17 Voltage Offset Correction: v_off_ini = -172.050 uV, v_off_fin = -173.916 uV 15:25:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.255 uVs 15:25:17 Integrated Voltage Measurement... 15:25:26 Voltage Offset Correction: v_off_ini = -183.038 uV, v_off_fin = -181.211 uV 15:25:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.028 uVs 15:25:26 Integrated Voltage Measurement... 15:25:35 Voltage Offset Correction: v_off_ini = -192.269 uV, v_off_fin = -192.981 uV 15:25:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.242 uVs 15:25:35 Integrated Voltage Measurement... 15:25:44 Voltage Offset Correction: v_off_ini = -192.351 uV, v_off_fin = -207.366 uV 15:25:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.170 uVs 15:25:44 Integrated Voltage Measurement... 15:25:53 Voltage Offset Correction: v_off_ini = -197.883 uV, v_off_fin = -195.547 uV 15:25:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.503 uVs 15:25:58 I1X Average and RMS of Measurements VT = -33.160 +- 8.439 uVs I1X = 6.632 +- 1.688 uTm 15:26:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:04 Integrated Voltage Measurement... 15:26:13 Voltage Offset Correction: v_off_ini = -215.840 uV, v_off_fin = -215.787 uV 15:26:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.110 uVs 15:26:13 Integrated Voltage Measurement... 15:26:22 Voltage Offset Correction: v_off_ini = -189.729 uV, v_off_fin = -190.228 uV 15:26:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.648 uVs 15:26:22 Integrated Voltage Measurement... 15:26:31 Voltage Offset Correction: v_off_ini = -191.534 uV, v_off_fin = -210.663 uV 15:26:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.788 uVs 15:26:31 Integrated Voltage Measurement... 15:26:40 Voltage Offset Correction: v_off_ini = -189.224 uV, v_off_fin = -180.180 uV 15:26:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 122.628 uVs 15:26:40 Integrated Voltage Measurement... 15:26:49 Voltage Offset Correction: v_off_ini = -174.142 uV, v_off_fin = -192.156 uV 15:26:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.679 uVs 15:26:49 Integrated Voltage Measurement... 15:26:58 Voltage Offset Correction: v_off_ini = -185.474 uV, v_off_fin = -177.810 uV 15:26:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 127.963 uVs 15:27:03 I1Y Average and RMS of Measurements VT = -129.969 +- 1.069 uVs I1Y = -25.994 +- 0.214 uTm 15:27:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:10 Integrated Voltage Measurement... 15:27:19 Voltage Offset Correction: v_off_ini = -188.895 uV, v_off_fin = -176.533 uV 15:27:19 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -53.289 uVs 15:27:19 Integrated Voltage Measurement... 15:27:28 Voltage Offset Correction: v_off_ini = -189.054 uV, v_off_fin = -213.375 uV 15:27:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.323 uVs 15:27:28 Integrated Voltage Measurement... 15:27:37 Voltage Offset Correction: v_off_ini = -192.215 uV, v_off_fin = -173.972 uV 15:27:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.877 uVs 15:27:37 Integrated Voltage Measurement... 15:27:46 Voltage Offset Correction: v_off_ini = -202.603 uV, v_off_fin = -214.746 uV 15:27:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.402 uVs 15:27:46 Integrated Voltage Measurement... 15:27:55 Voltage Offset Correction: v_off_ini = -212.859 uV, v_off_fin = -178.100 uV 15:27:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.087 uVs 15:27:55 Integrated Voltage Measurement... 15:28:04 Voltage Offset Correction: v_off_ini = -194.667 uV, v_off_fin = -200.042 uV 15:28:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.682 uVs 15:28:07 I2X Average and RMS of Measurements VT = -56.610 +- 7.705 uVs I2X = 5.208 +- 0.709 uTm^2 15:28:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:15 Integrated Voltage Measurement... 15:28:24 Voltage Offset Correction: v_off_ini = -208.222 uV, v_off_fin = -202.179 uV 15:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -138.243 uVs 15:28:24 Integrated Voltage Measurement... 15:28:33 Voltage Offset Correction: v_off_ini = -192.790 uV, v_off_fin = -202.354 uV 15:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.100 uVs 15:28:33 Integrated Voltage Measurement... 15:28:42 Voltage Offset Correction: v_off_ini = -204.986 uV, v_off_fin = -212.777 uV 15:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.348 uVs 15:28:42 Integrated Voltage Measurement... 15:28:51 Voltage Offset Correction: v_off_ini = -198.675 uV, v_off_fin = -201.713 uV 15:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 147.469 uVs 15:28:51 Integrated Voltage Measurement... 15:29:00 Voltage Offset Correction: v_off_ini = -215.072 uV, v_off_fin = -221.834 uV 15:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.268 uVs 15:29:00 Integrated Voltage Measurement... 15:29:09 Voltage Offset Correction: v_off_ini = -220.710 uV, v_off_fin = -210.511 uV 15:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.122 uVs 15:29:11 I2Y Average and RMS of Measurements VT = -156.258 +- 10.084 uVs I2Y = -14.376 +- 0.928 uTm^2 15:29:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:25 Integrated Voltage Measurement... 15:29:34 Voltage Offset Correction: v_off_ini = -210.417 uV, v_off_fin = -200.110 uV 15:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -14.029 uVs 15:29:34 Integrated Voltage Measurement... 15:29:43 Voltage Offset Correction: v_off_ini = -193.800 uV, v_off_fin = -193.816 uV 15:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.003 uVs 15:29:43 Integrated Voltage Measurement... 15:29:52 Voltage Offset Correction: v_off_ini = -205.298 uV, v_off_fin = -208.004 uV 15:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.329 uVs 15:29:52 Integrated Voltage Measurement... 15:30:01 Voltage Offset Correction: v_off_ini = -208.289 uV, v_off_fin = -193.351 uV 15:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.108 uVs 15:30:01 Integrated Voltage Measurement... 15:30:10 Voltage Offset Correction: v_off_ini = -214.532 uV, v_off_fin = -192.833 uV 15:30:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.788 uVs 15:30:10 Integrated Voltage Measurement... 15:30:19 Voltage Offset Correction: v_off_ini = -190.744 uV, v_off_fin = -198.599 uV 15:30:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.361 uVs 15:30:23 I1X Average and RMS of Measurements VT = -30.936 +- 7.237 uVs I1X = 6.187 +- 1.447 uTm 15:30:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:30 Integrated Voltage Measurement... 15:30:39 Voltage Offset Correction: v_off_ini = -202.506 uV, v_off_fin = -200.522 uV 15:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.122 uVs 15:30:39 Integrated Voltage Measurement... 15:30:48 Voltage Offset Correction: v_off_ini = -198.387 uV, v_off_fin = -187.222 uV 15:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.152 uVs 15:30:48 Integrated Voltage Measurement... 15:30:57 Voltage Offset Correction: v_off_ini = -191.064 uV, v_off_fin = -207.687 uV 15:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -117.662 uVs 15:30:57 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = -211.637 uV, v_off_fin = -200.405 uV 15:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 136.938 uVs 15:31:06 Integrated Voltage Measurement... 15:31:15 Voltage Offset Correction: v_off_ini = -204.170 uV, v_off_fin = -218.954 uV 15:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.974 uVs 15:31:15 Integrated Voltage Measurement... 15:31:24 Voltage Offset Correction: v_off_ini = -210.976 uV, v_off_fin = -196.155 uV 15:31:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 127.735 uVs 15:31:28 I1Y Average and RMS of Measurements VT = -131.764 +- 3.233 uVs I1Y = -26.352 +- 0.646 uTm 15:31:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:36 Integrated Voltage Measurement... 15:31:45 Voltage Offset Correction: v_off_ini = -206.457 uV, v_off_fin = -206.057 uV 15:31:45 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -47.010 uVs 15:31:45 Integrated Voltage Measurement... 15:31:54 Voltage Offset Correction: v_off_ini = -210.647 uV, v_off_fin = -205.963 uV 15:31:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.404 uVs 15:31:54 Integrated Voltage Measurement... 15:32:03 Voltage Offset Correction: v_off_ini = -191.686 uV, v_off_fin = -191.614 uV 15:32:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.085 uVs 15:32:03 Integrated Voltage Measurement... 15:32:12 Voltage Offset Correction: v_off_ini = -204.536 uV, v_off_fin = -197.569 uV 15:32:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.255 uVs 15:32:12 Integrated Voltage Measurement... 15:32:21 Voltage Offset Correction: v_off_ini = -198.958 uV, v_off_fin = -185.344 uV 15:32:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.511 uVs 15:32:21 Integrated Voltage Measurement... 15:32:30 Voltage Offset Correction: v_off_ini = -218.396 uV, v_off_fin = -217.557 uV 15:32:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.113 uVs 15:32:33 I2X Average and RMS of Measurements VT = -50.896 +- 3.269 uVs I2X = 4.682 +- 0.301 uTm^2 15:32:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:41 Integrated Voltage Measurement... 15:32:50 Voltage Offset Correction: v_off_ini = -183.940 uV, v_off_fin = -220.189 uV 15:32:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.979 uVs 15:32:50 Integrated Voltage Measurement... 15:32:59 Voltage Offset Correction: v_off_ini = -203.150 uV, v_off_fin = -187.405 uV 15:32:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.304 uVs 15:32:59 Integrated Voltage Measurement... 15:33:08 Voltage Offset Correction: v_off_ini = -190.285 uV, v_off_fin = -193.069 uV 15:33:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.659 uVs 15:33:08 Integrated Voltage Measurement... 15:33:17 Voltage Offset Correction: v_off_ini = -190.410 uV, v_off_fin = -183.335 uV 15:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 156.271 uVs 15:33:17 Integrated Voltage Measurement... 15:33:26 Voltage Offset Correction: v_off_ini = -200.743 uV, v_off_fin = -190.927 uV 15:33:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.645 uVs 15:33:26 Integrated Voltage Measurement... 15:33:35 Voltage Offset Correction: v_off_ini = -184.254 uV, v_off_fin = -191.427 uV 15:33:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.292 uVs 15:33:37 I2Y Average and RMS of Measurements VT = -154.358 +- 3.858 uVs I2Y = -14.201 +- 0.355 uTm^2 15:33:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:51 Integrated Voltage Measurement... 15:34:00 Voltage Offset Correction: v_off_ini = -184.088 uV, v_off_fin = -175.975 uV 15:34:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.237 uVs 15:34:00 Integrated Voltage Measurement... 15:34:09 Voltage Offset Correction: v_off_ini = -195.656 uV, v_off_fin = -187.923 uV 15:34:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.076 uVs 15:34:09 Integrated Voltage Measurement... 15:34:18 Voltage Offset Correction: v_off_ini = -187.341 uV, v_off_fin = -201.133 uV 15:34:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.738 uVs 15:34:18 Integrated Voltage Measurement... 15:34:27 Voltage Offset Correction: v_off_ini = -193.894 uV, v_off_fin = -187.343 uV 15:34:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.760 uVs 15:34:27 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = -191.026 uV, v_off_fin = -193.569 uV 15:34:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.198 uVs 15:34:36 Integrated Voltage Measurement... 15:34:45 Voltage Offset Correction: v_off_ini = -174.134 uV, v_off_fin = -177.914 uV 15:34:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.487 uVs 15:34:49 I1X Average and RMS of Measurements VT = -44.583 +- 2.994 uVs I1X = 8.917 +- 0.599 uTm 15:34:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:56 Integrated Voltage Measurement... 15:35:05 Voltage Offset Correction: v_off_ini = -194.246 uV, v_off_fin = -195.984 uV 15:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -111.418 uVs 15:35:05 Integrated Voltage Measurement... 15:35:14 Voltage Offset Correction: v_off_ini = -188.347 uV, v_off_fin = -183.966 uV 15:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 127.998 uVs 15:35:14 Integrated Voltage Measurement... 15:35:23 Voltage Offset Correction: v_off_ini = -192.289 uV, v_off_fin = -199.154 uV 15:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -129.387 uVs 15:35:23 Integrated Voltage Measurement... 15:35:32 Voltage Offset Correction: v_off_ini = -197.500 uV, v_off_fin = -180.030 uV 15:35:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 135.263 uVs 15:35:32 Integrated Voltage Measurement... 15:35:41 Voltage Offset Correction: v_off_ini = -204.712 uV, v_off_fin = -209.743 uV 15:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -125.658 uVs 15:35:41 Integrated Voltage Measurement... 15:35:50 Voltage Offset Correction: v_off_ini = -190.626 uV, v_off_fin = -180.596 uV 15:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 128.428 uVs 15:35:54 I1Y Average and RMS of Measurements VT = -126.359 +- 5.173 uVs I1Y = -25.271 +- 1.034 uTm 15:35:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:02 Integrated Voltage Measurement... 15:36:11 Voltage Offset Correction: v_off_ini = -187.157 uV, v_off_fin = -186.820 uV 15:36:11 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -48.758 uVs 15:36:11 Integrated Voltage Measurement... 15:36:20 Voltage Offset Correction: v_off_ini = -195.874 uV, v_off_fin = -204.693 uV 15:36:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.964 uVs 15:36:20 Integrated Voltage Measurement... 15:36:29 Voltage Offset Correction: v_off_ini = -193.389 uV, v_off_fin = -187.875 uV 15:36:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.303 uVs 15:36:29 Integrated Voltage Measurement... 15:36:38 Voltage Offset Correction: v_off_ini = -208.363 uV, v_off_fin = -213.113 uV 15:36:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.076 uVs 15:36:38 Integrated Voltage Measurement... 15:36:47 Voltage Offset Correction: v_off_ini = -199.198 uV, v_off_fin = -183.078 uV 15:36:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.647 uVs 15:36:47 Integrated Voltage Measurement... 15:36:56 Voltage Offset Correction: v_off_ini = -197.359 uV, v_off_fin = -209.204 uV 15:36:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.689 uVs 15:36:59 I2X Average and RMS of Measurements VT = -51.739 +- 4.318 uVs I2X = 4.760 +- 0.397 uTm^2 15:37:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:06 Integrated Voltage Measurement... 15:37:15 Voltage Offset Correction: v_off_ini = -198.054 uV, v_off_fin = -200.782 uV 15:37:15 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -144.785 uVs 15:37:15 Integrated Voltage Measurement... 15:37:24 Voltage Offset Correction: v_off_ini = -209.001 uV, v_off_fin = -199.779 uV 15:37:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.593 uVs 15:37:25 Integrated Voltage Measurement... 15:37:34 Voltage Offset Correction: v_off_ini = -200.978 uV, v_off_fin = -201.114 uV 15:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -122.952 uVs 15:37:34 Integrated Voltage Measurement... 15:37:43 Voltage Offset Correction: v_off_ini = -216.802 uV, v_off_fin = -200.916 uV 15:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.661 uVs 15:37:43 Integrated Voltage Measurement... 15:37:52 Voltage Offset Correction: v_off_ini = -196.327 uV, v_off_fin = -197.997 uV 15:37:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.460 uVs 15:37:52 Integrated Voltage Measurement... 15:38:01 Voltage Offset Correction: v_off_ini = -197.667 uV, v_off_fin = -200.362 uV 15:38:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 147.313 uVs 15:38:03 I2Y Average and RMS of Measurements VT = -144.794 +- 10.636 uVs I2Y = -13.321 +- 0.978 uTm^2 15:38:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:17 Integrated Voltage Measurement... 15:38:26 Voltage Offset Correction: v_off_ini = -201.771 uV, v_off_fin = -198.728 uV 15:38:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.521 uVs 15:38:26 Integrated Voltage Measurement... 15:38:35 Voltage Offset Correction: v_off_ini = -179.657 uV, v_off_fin = -170.012 uV 15:38:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.894 uVs 15:38:35 Integrated Voltage Measurement... 15:38:44 Voltage Offset Correction: v_off_ini = -185.719 uV, v_off_fin = -178.854 uV 15:38:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.060 uVs 15:38:44 Integrated Voltage Measurement... 15:38:53 Voltage Offset Correction: v_off_ini = -197.015 uV, v_off_fin = -167.250 uV 15:38:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.720 uVs 15:38:53 Integrated Voltage Measurement... 15:39:02 Voltage Offset Correction: v_off_ini = -178.723 uV, v_off_fin = -172.803 uV 15:39:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.134 uVs 15:39:02 Integrated Voltage Measurement... 15:39:11 Voltage Offset Correction: v_off_ini = -171.980 uV, v_off_fin = -169.352 uV 15:39:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.221 uVs 15:39:15 I1X Average and RMS of Measurements VT = -29.925 +- 7.028 uVs I1X = 5.985 +- 1.406 uTm 15:39:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:22 Integrated Voltage Measurement... 15:39:31 Voltage Offset Correction: v_off_ini = -157.960 uV, v_off_fin = -164.363 uV 15:39:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.434 uVs 15:39:31 Integrated Voltage Measurement... 15:39:40 Voltage Offset Correction: v_off_ini = -153.739 uV, v_off_fin = -155.525 uV 15:39:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.119 uVs 15:39:40 Integrated Voltage Measurement... 15:39:49 Voltage Offset Correction: v_off_ini = -157.596 uV, v_off_fin = -161.583 uV 15:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -121.266 uVs 15:39:49 Integrated Voltage Measurement... 15:39:58 Voltage Offset Correction: v_off_ini = -150.191 uV, v_off_fin = -149.499 uV 15:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 124.471 uVs 15:39:58 Integrated Voltage Measurement... 15:40:07 Voltage Offset Correction: v_off_ini = -173.705 uV, v_off_fin = -184.132 uV 15:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -121.325 uVs 15:40:07 Integrated Voltage Measurement... 15:40:16 Voltage Offset Correction: v_off_ini = -165.915 uV, v_off_fin = -150.225 uV 15:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 123.637 uVs 15:40:20 I1Y Average and RMS of Measurements VT = -126.209 +- 5.000 uVs I1Y = -25.242 +- 1.000 uTm 15:40:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:28 Integrated Voltage Measurement... 15:40:37 Voltage Offset Correction: v_off_ini = -148.571 uV, v_off_fin = -153.675 uV 15:40:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -51.123 uVs 15:40:37 Integrated Voltage Measurement... 15:40:46 Voltage Offset Correction: v_off_ini = -166.750 uV, v_off_fin = -179.113 uV 15:40:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.152 uVs 15:40:46 Integrated Voltage Measurement... 15:40:55 Voltage Offset Correction: v_off_ini = -159.893 uV, v_off_fin = -155.472 uV 15:40:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.418 uVs 15:40:55 Integrated Voltage Measurement... 15:41:04 Voltage Offset Correction: v_off_ini = -188.668 uV, v_off_fin = -172.745 uV 15:41:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.460 uVs 15:41:04 Integrated Voltage Measurement... 15:41:13 Voltage Offset Correction: v_off_ini = -166.345 uV, v_off_fin = -160.014 uV 15:41:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.328 uVs 15:41:13 Integrated Voltage Measurement... 15:41:22 Voltage Offset Correction: v_off_ini = -163.921 uV, v_off_fin = -162.813 uV 15:41:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.762 uVs 15:41:25 I2X Average and RMS of Measurements VT = -46.207 +- 5.573 uVs I2X = 4.251 +- 0.513 uTm^2 15:41:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:32 Integrated Voltage Measurement... 15:41:41 Voltage Offset Correction: v_off_ini = -150.999 uV, v_off_fin = -159.944 uV 15:41:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.512 uVs 15:41:41 Integrated Voltage Measurement... 15:41:50 Voltage Offset Correction: v_off_ini = -156.291 uV, v_off_fin = -152.094 uV 15:41:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 154.335 uVs 15:41:51 Integrated Voltage Measurement... 15:41:59 Voltage Offset Correction: v_off_ini = -156.223 uV, v_off_fin = -151.475 uV 15:42:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.159 uVs 15:42:00 Integrated Voltage Measurement... 15:42:09 Voltage Offset Correction: v_off_ini = -150.331 uV, v_off_fin = -154.242 uV 15:42:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.262 uVs 15:42:09 Integrated Voltage Measurement... 15:42:18 Voltage Offset Correction: v_off_ini = -167.484 uV, v_off_fin = -155.465 uV 15:42:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.659 uVs 15:42:18 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = -154.210 uV, v_off_fin = -147.731 uV 15:42:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.803 uVs 15:42:29 I2Y Average and RMS of Measurements VT = -156.455 +- 5.854 uVs I2Y = -14.394 +- 0.539 uTm^2 15:42:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:44 Integrated Voltage Measurement... 15:42:53 Voltage Offset Correction: v_off_ini = -156.878 uV, v_off_fin = -148.553 uV 15:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.600 uVs 15:42:53 Integrated Voltage Measurement... 15:43:02 Voltage Offset Correction: v_off_ini = -144.600 uV, v_off_fin = -149.940 uV 15:43:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.880 uVs 15:43:02 Integrated Voltage Measurement... 15:43:11 Voltage Offset Correction: v_off_ini = -161.866 uV, v_off_fin = -148.486 uV 15:43:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.481 uVs 15:43:11 Integrated Voltage Measurement... 15:43:20 Voltage Offset Correction: v_off_ini = -147.414 uV, v_off_fin = -137.917 uV 15:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.563 uVs 15:43:20 Integrated Voltage Measurement... 15:43:29 Voltage Offset Correction: v_off_ini = -154.918 uV, v_off_fin = -144.370 uV 15:43:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.691 uVs 15:43:29 Integrated Voltage Measurement... 15:43:38 Voltage Offset Correction: v_off_ini = -143.955 uV, v_off_fin = -136.838 uV 15:43:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.160 uVs 15:43:42 I1X Average and RMS of Measurements VT = -27.563 +- 2.827 uVs I1X = 5.513 +- 0.565 uTm 15:43:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:49 Integrated Voltage Measurement... 15:43:58 Voltage Offset Correction: v_off_ini = -150.063 uV, v_off_fin = -169.315 uV 15:43:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.780 uVs 15:43:58 Integrated Voltage Measurement... 15:44:07 Voltage Offset Correction: v_off_ini = -144.899 uV, v_off_fin = -146.968 uV 15:44:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.481 uVs 15:44:07 Integrated Voltage Measurement... 15:44:16 Voltage Offset Correction: v_off_ini = -146.707 uV, v_off_fin = -158.657 uV 15:44:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.292 uVs 15:44:16 Integrated Voltage Measurement... 15:44:25 Voltage Offset Correction: v_off_ini = -147.552 uV, v_off_fin = -139.000 uV 15:44:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 124.759 uVs 15:44:25 Integrated Voltage Measurement... 15:44:34 Voltage Offset Correction: v_off_ini = -153.208 uV, v_off_fin = -155.948 uV 15:44:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -117.900 uVs 15:44:34 Integrated Voltage Measurement... 15:44:43 Voltage Offset Correction: v_off_ini = -148.571 uV, v_off_fin = -131.178 uV 15:44:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 121.142 uVs 15:44:47 I1Y Average and RMS of Measurements VT = -132.226 +- 9.323 uVs I1Y = -26.444 +- 1.866 uTm 15:44:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:55 Integrated Voltage Measurement... 15:45:04 Voltage Offset Correction: v_off_ini = -156.691 uV, v_off_fin = -142.614 uV 15:45:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -34.029 uVs 15:45:04 Integrated Voltage Measurement... 15:45:13 Voltage Offset Correction: v_off_ini = -154.135 uV, v_off_fin = -155.492 uV 15:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.277 uVs 15:45:13 Integrated Voltage Measurement... 15:45:22 Voltage Offset Correction: v_off_ini = -151.512 uV, v_off_fin = -146.505 uV 15:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.916 uVs 15:45:22 Integrated Voltage Measurement... 15:45:31 Voltage Offset Correction: v_off_ini = -161.363 uV, v_off_fin = -160.010 uV 15:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.807 uVs 15:45:31 Integrated Voltage Measurement... 15:45:40 Voltage Offset Correction: v_off_ini = -173.304 uV, v_off_fin = -154.140 uV 15:45:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.986 uVs 15:45:40 Integrated Voltage Measurement... 15:45:49 Voltage Offset Correction: v_off_ini = -155.828 uV, v_off_fin = -163.753 uV 15:45:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.235 uVs 15:45:52 I2X Average and RMS of Measurements VT = -43.542 +- 12.761 uVs I2X = 4.006 +- 1.174 uTm^2 15:45:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:59 Integrated Voltage Measurement... 15:46:08 Voltage Offset Correction: v_off_ini = -147.180 uV, v_off_fin = -139.569 uV 15:46:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.744 uVs 15:46:08 Integrated Voltage Measurement... 15:46:17 Voltage Offset Correction: v_off_ini = -139.199 uV, v_off_fin = -143.761 uV 15:46:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.668 uVs 15:46:17 Integrated Voltage Measurement... 15:46:26 Voltage Offset Correction: v_off_ini = -138.878 uV, v_off_fin = -149.544 uV 15:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -160.828 uVs 15:46:27 Integrated Voltage Measurement... 15:46:36 Voltage Offset Correction: v_off_ini = -152.005 uV, v_off_fin = -146.618 uV 15:46:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 150.818 uVs 15:46:36 Integrated Voltage Measurement... 15:46:45 Voltage Offset Correction: v_off_ini = -134.813 uV, v_off_fin = -148.042 uV 15:46:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -143.617 uVs 15:46:45 Integrated Voltage Measurement... 15:46:54 Voltage Offset Correction: v_off_ini = -138.325 uV, v_off_fin = -131.727 uV 15:46:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.614 uVs 15:46:56 I2Y Average and RMS of Measurements VT = -151.548 +- 4.047 uVs I2Y = -13.942 +- 0.372 uTm^2 15:47:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = -149.719 uV, v_off_fin = -143.869 uV 15:47:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.554 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = -132.420 uV, v_off_fin = -125.106 uV 15:47:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.261 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = -129.143 uV, v_off_fin = -138.341 uV 15:47:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.229 uVs 15:47:38 Integrated Voltage Measurement... 15:47:47 Voltage Offset Correction: v_off_ini = -147.279 uV, v_off_fin = -133.158 uV 15:47:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.463 uVs 15:47:47 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = -138.279 uV, v_off_fin = -137.062 uV 15:47:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.663 uVs 15:47:56 Integrated Voltage Measurement... 15:48:05 Voltage Offset Correction: v_off_ini = -131.161 uV, v_off_fin = -136.024 uV 15:48:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.742 uVs 15:48:09 I1X Average and RMS of Measurements VT = -29.819 +- 3.182 uVs I1X = 5.964 +- 0.636 uTm 15:48:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:16 Integrated Voltage Measurement... 15:48:25 Voltage Offset Correction: v_off_ini = -122.729 uV, v_off_fin = -136.059 uV 15:48:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.427 uVs 15:48:25 Integrated Voltage Measurement... 15:48:34 Voltage Offset Correction: v_off_ini = -135.506 uV, v_off_fin = -147.642 uV 15:48:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.697 uVs 15:48:34 Integrated Voltage Measurement... 15:48:43 Voltage Offset Correction: v_off_ini = -122.556 uV, v_off_fin = -136.258 uV 15:48:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -133.485 uVs 15:48:43 Integrated Voltage Measurement... 15:48:52 Voltage Offset Correction: v_off_ini = -118.776 uV, v_off_fin = -130.740 uV 15:48:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.977 uVs 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = -128.086 uV, v_off_fin = -134.847 uV 15:49:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -136.044 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = -119.577 uV, v_off_fin = -117.786 uV 15:49:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 136.897 uVs 15:49:14 I1Y Average and RMS of Measurements VT = -144.921 +- 6.432 uVs I1Y = -28.984 +- 1.287 uTm 15:49:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:22 Integrated Voltage Measurement... 15:49:31 Voltage Offset Correction: v_off_ini = -102.839 uV, v_off_fin = -104.152 uV 15:49:31 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -36.651 uVs 15:49:31 Integrated Voltage Measurement... 15:49:40 Voltage Offset Correction: v_off_ini = -119.500 uV, v_off_fin = -134.847 uV 15:49:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.322 uVs 15:49:40 Integrated Voltage Measurement... 15:49:49 Voltage Offset Correction: v_off_ini = -128.198 uV, v_off_fin = -119.779 uV 15:49:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.019 uVs 15:49:49 Integrated Voltage Measurement... 15:49:58 Voltage Offset Correction: v_off_ini = -128.750 uV, v_off_fin = -130.383 uV 15:49:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.283 uVs 15:49:58 Integrated Voltage Measurement... 15:50:07 Voltage Offset Correction: v_off_ini = -132.632 uV, v_off_fin = -117.888 uV 15:50:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.292 uVs 15:50:07 Integrated Voltage Measurement... 15:50:16 Voltage Offset Correction: v_off_ini = -119.370 uV, v_off_fin = -131.350 uV 15:50:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.727 uVs 15:50:19 I2X Average and RMS of Measurements VT = -45.049 +- 7.281 uVs I2X = 4.144 +- 0.670 uTm^2 15:50:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:26 Integrated Voltage Measurement... 15:50:35 Voltage Offset Correction: v_off_ini = -110.723 uV, v_off_fin = -119.044 uV 15:50:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.689 uVs 15:50:35 Integrated Voltage Measurement... 15:50:44 Voltage Offset Correction: v_off_ini = -119.211 uV, v_off_fin = -124.739 uV 15:50:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.259 uVs 15:50:44 Integrated Voltage Measurement... 15:50:53 Voltage Offset Correction: v_off_ini = -134.093 uV, v_off_fin = -133.966 uV 15:50:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -154.951 uVs 15:50:54 Integrated Voltage Measurement... 15:51:03 Voltage Offset Correction: v_off_ini = -115.187 uV, v_off_fin = -132.318 uV 15:51:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.476 uVs 15:51:03 Integrated Voltage Measurement... 15:51:12 Voltage Offset Correction: v_off_ini = -137.527 uV, v_off_fin = -122.116 uV 15:51:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.244 uVs 15:51:12 Integrated Voltage Measurement... 15:51:21 Voltage Offset Correction: v_off_ini = -117.325 uV, v_off_fin = -104.819 uV 15:51:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.462 uVs 15:51:23 I2Y Average and RMS of Measurements VT = -166.013 +- 4.469 uVs I2Y = -15.273 +- 0.411 uTm^2 15:51:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:40 Integrated Voltage Measurement... 15:51:49 Voltage Offset Correction: v_off_ini = -137.780 uV, v_off_fin = -130.199 uV 15:51:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.255 uVs 15:51:49 Integrated Voltage Measurement... 15:51:58 Voltage Offset Correction: v_off_ini = -130.317 uV, v_off_fin = -131.037 uV 15:51:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.799 uVs 15:51:58 Integrated Voltage Measurement... 15:52:07 Voltage Offset Correction: v_off_ini = -121.267 uV, v_off_fin = -115.086 uV 15:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.016 uVs 15:52:07 Integrated Voltage Measurement... 15:52:16 Voltage Offset Correction: v_off_ini = -105.867 uV, v_off_fin = -108.700 uV 15:52:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.688 uVs 15:52:16 Integrated Voltage Measurement... 15:52:25 Voltage Offset Correction: v_off_ini = -120.963 uV, v_off_fin = -109.754 uV 15:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.039 uVs 15:52:25 Integrated Voltage Measurement... 15:52:34 Voltage Offset Correction: v_off_ini = -96.812 uV, v_off_fin = -104.311 uV 15:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.173 uVs 15:52:39 I1X Average and RMS of Measurements VT = -44.328 +- 7.328 uVs I1X = 8.866 +- 1.466 uTm 15:52:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:45 Integrated Voltage Measurement... 15:52:54 Voltage Offset Correction: v_off_ini = -110.285 uV, v_off_fin = -113.069 uV 15:52:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.105 uVs 15:52:54 Integrated Voltage Measurement... 15:53:03 Voltage Offset Correction: v_off_ini = -94.426 uV, v_off_fin = -82.151 uV 15:53:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.276 uVs 15:53:03 Integrated Voltage Measurement... 15:53:12 Voltage Offset Correction: v_off_ini = -115.137 uV, v_off_fin = -124.729 uV 15:53:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.045 uVs 15:53:12 Integrated Voltage Measurement... 15:53:21 Voltage Offset Correction: v_off_ini = -101.943 uV, v_off_fin = -91.702 uV 15:53:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.900 uVs 15:53:21 Integrated Voltage Measurement... 15:53:30 Voltage Offset Correction: v_off_ini = -88.502 uV, v_off_fin = -97.922 uV 15:53:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.483 uVs 15:53:30 Integrated Voltage Measurement... 15:53:39 Voltage Offset Correction: v_off_ini = -96.226 uV, v_off_fin = -75.122 uV 15:53:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.558 uVs 15:53:44 I1Y Average and RMS of Measurements VT = -149.061 +- 7.337 uVs I1Y = -29.812 +- 1.467 uTm 15:53:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:51 Integrated Voltage Measurement... 15:54:00 Voltage Offset Correction: v_off_ini = -89.190 uV, v_off_fin = -84.076 uV 15:54:00 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -77.427 uVs 15:54:00 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = -97.548 uV, v_off_fin = -121.551 uV 15:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.789 uVs 15:54:09 Integrated Voltage Measurement... 15:54:18 Voltage Offset Correction: v_off_ini = -92.871 uV, v_off_fin = -98.397 uV 15:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.686 uVs 15:54:18 Integrated Voltage Measurement... 15:54:27 Voltage Offset Correction: v_off_ini = -108.056 uV, v_off_fin = -106.218 uV 15:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.852 uVs 15:54:27 Integrated Voltage Measurement... 15:54:36 Voltage Offset Correction: v_off_ini = -96.646 uV, v_off_fin = -83.810 uV 15:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.959 uVs 15:54:36 Integrated Voltage Measurement... 15:54:45 Voltage Offset Correction: v_off_ini = -101.361 uV, v_off_fin = -105.834 uV 15:54:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.857 uVs 15:54:48 I2X Average and RMS of Measurements VT = -60.762 +- 7.439 uVs I2X = 5.590 +- 0.684 uTm^2 15:54:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:56 Integrated Voltage Measurement... 15:55:05 Voltage Offset Correction: v_off_ini = -92.849 uV, v_off_fin = -104.993 uV 15:55:05 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -208.173 uVs 15:55:05 Integrated Voltage Measurement... 15:55:14 Voltage Offset Correction: v_off_ini = -93.176 uV, v_off_fin = -92.306 uV 15:55:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.994 uVs 15:55:14 Integrated Voltage Measurement... 15:55:23 Voltage Offset Correction: v_off_ini = -104.026 uV, v_off_fin = -109.028 uV 15:55:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.985 uVs 15:55:23 Integrated Voltage Measurement... 15:55:32 Voltage Offset Correction: v_off_ini = -118.259 uV, v_off_fin = -105.346 uV 15:55:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.304 uVs 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = -98.259 uV, v_off_fin = -102.463 uV 15:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.443 uVs 15:55:41 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = -88.058 uV, v_off_fin = -116.405 uV 15:55:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.639 uVs 15:55:52 I2Y Average and RMS of Measurements VT = -178.590 +- 2.059 uVs I2Y = -16.430 +- 0.189 uTm^2 15:56:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:10 Integrated Voltage Measurement... 15:56:18 Voltage Offset Correction: v_off_ini = -102.294 uV, v_off_fin = -101.893 uV 15:56:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -39.381 uVs 15:56:19 Integrated Voltage Measurement... 15:56:27 Voltage Offset Correction: v_off_ini = -94.057 uV, v_off_fin = -109.997 uV 15:56:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.936 uVs 15:56:28 Integrated Voltage Measurement... 15:56:37 Voltage Offset Correction: v_off_ini = -115.405 uV, v_off_fin = -102.694 uV 15:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.244 uVs 15:56:37 Integrated Voltage Measurement... 15:56:46 Voltage Offset Correction: v_off_ini = -99.903 uV, v_off_fin = -97.651 uV 15:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.114 uVs 15:56:46 Integrated Voltage Measurement... 15:56:55 Voltage Offset Correction: v_off_ini = -109.369 uV, v_off_fin = -121.942 uV 15:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.706 uVs 15:56:55 Integrated Voltage Measurement... 15:57:04 Voltage Offset Correction: v_off_ini = -109.937 uV, v_off_fin = -116.734 uV 15:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.681 uVs 15:57:08 I1X Average and RMS of Measurements VT = -42.843 +- 1.192 uVs I1X = 8.569 +- 0.238 uTm 15:57:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:15 Integrated Voltage Measurement... 15:57:24 Voltage Offset Correction: v_off_ini = -116.666 uV, v_off_fin = -125.421 uV 15:57:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.923 uVs 15:57:24 Integrated Voltage Measurement... 15:57:33 Voltage Offset Correction: v_off_ini = -126.259 uV, v_off_fin = -116.948 uV 15:57:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.783 uVs 15:57:33 Integrated Voltage Measurement... 15:57:41 Voltage Offset Correction: v_off_ini = -127.993 uV, v_off_fin = -131.594 uV 15:57:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.027 uVs 15:57:42 Integrated Voltage Measurement... 15:57:50 Voltage Offset Correction: v_off_ini = -142.279 uV, v_off_fin = -109.805 uV 15:57:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.190 uVs 15:57:51 Integrated Voltage Measurement... 15:57:59 Voltage Offset Correction: v_off_ini = -122.304 uV, v_off_fin = -125.262 uV 15:57:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.588 uVs 15:58:00 Integrated Voltage Measurement... 15:58:08 Voltage Offset Correction: v_off_ini = -117.445 uV, v_off_fin = -107.061 uV 15:58:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.927 uVs 15:58:13 I1Y Average and RMS of Measurements VT = -177.073 +- 5.481 uVs I1Y = -35.415 +- 1.096 uTm 15:58:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:20 Integrated Voltage Measurement... 15:58:29 Voltage Offset Correction: v_off_ini = -115.495 uV, v_off_fin = -106.450 uV 15:58:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -82.985 uVs 15:58:29 Integrated Voltage Measurement... 15:58:38 Voltage Offset Correction: v_off_ini = -118.676 uV, v_off_fin = -117.091 uV 15:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.884 uVs 15:58:38 Integrated Voltage Measurement... 15:58:47 Voltage Offset Correction: v_off_ini = -114.191 uV, v_off_fin = -101.735 uV 15:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.851 uVs 15:58:48 Integrated Voltage Measurement... 15:58:56 Voltage Offset Correction: v_off_ini = -108.658 uV, v_off_fin = -119.650 uV 15:58:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.892 uVs 15:58:57 Integrated Voltage Measurement... 15:59:06 Voltage Offset Correction: v_off_ini = -101.953 uV, v_off_fin = -115.728 uV 15:59:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.342 uVs 15:59:06 Integrated Voltage Measurement... 15:59:15 Voltage Offset Correction: v_off_ini = -105.177 uV, v_off_fin = -136.787 uV 15:59:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.926 uVs 15:59:17 I2X Average and RMS of Measurements VT = -66.814 +- 6.894 uVs I2X = 6.147 +- 0.634 uTm^2 15:59:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:25 Integrated Voltage Measurement... 15:59:34 Voltage Offset Correction: v_off_ini = -105.974 uV, v_off_fin = -109.144 uV 15:59:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.460 uVs 15:59:34 Integrated Voltage Measurement... 15:59:43 Voltage Offset Correction: v_off_ini = -112.731 uV, v_off_fin = -103.784 uV 15:59:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.808 uVs 15:59:43 Integrated Voltage Measurement... 15:59:52 Voltage Offset Correction: v_off_ini = -101.120 uV, v_off_fin = -109.040 uV 15:59:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.589 uVs 15:59:52 Integrated Voltage Measurement... 16:00:01 Voltage Offset Correction: v_off_ini = -99.744 uV, v_off_fin = -95.646 uV 16:00:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 207.182 uVs 16:00:01 Integrated Voltage Measurement... 16:00:10 Voltage Offset Correction: v_off_ini = -110.831 uV, v_off_fin = -123.109 uV 16:00:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.423 uVs 16:00:10 Integrated Voltage Measurement... 16:00:19 Voltage Offset Correction: v_off_ini = -112.087 uV, v_off_fin = -104.961 uV 16:00:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.498 uVs 16:00:21 I2Y Average and RMS of Measurements VT = -191.160 +- 13.275 uVs I2Y = -17.587 +- 1.222 uTm^2 16:00:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:39 Integrated Voltage Measurement... 16:00:48 Voltage Offset Correction: v_off_ini = -110.048 uV, v_off_fin = -115.549 uV 16:00:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.178 uVs 16:00:48 Integrated Voltage Measurement... 16:00:57 Voltage Offset Correction: v_off_ini = -110.905 uV, v_off_fin = -117.906 uV 16:00:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.898 uVs 16:00:57 Integrated Voltage Measurement... 16:01:06 Voltage Offset Correction: v_off_ini = -126.664 uV, v_off_fin = -113.603 uV 16:01:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.234 uVs 16:01:06 Integrated Voltage Measurement... 16:01:15 Voltage Offset Correction: v_off_ini = -123.490 uV, v_off_fin = -114.363 uV 16:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.437 uVs 16:01:15 Integrated Voltage Measurement... 16:01:24 Voltage Offset Correction: v_off_ini = -128.286 uV, v_off_fin = -115.142 uV 16:01:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.784 uVs 16:01:24 Integrated Voltage Measurement... 16:01:33 Voltage Offset Correction: v_off_ini = -113.583 uV, v_off_fin = -117.354 uV 16:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.282 uVs 16:01:37 I1X Average and RMS of Measurements VT = -48.469 +- 5.608 uVs I1X = 9.694 +- 1.122 uTm 16:01:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:44 Integrated Voltage Measurement... 16:01:53 Voltage Offset Correction: v_off_ini = -116.459 uV, v_off_fin = -129.554 uV 16:01:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.285 uVs 16:01:53 Integrated Voltage Measurement... 16:02:02 Voltage Offset Correction: v_off_ini = -143.955 uV, v_off_fin = -137.200 uV 16:02:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.744 uVs 16:02:02 Integrated Voltage Measurement... 16:02:11 Voltage Offset Correction: v_off_ini = -134.949 uV, v_off_fin = -154.316 uV 16:02:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.975 uVs 16:02:11 Integrated Voltage Measurement... 16:02:20 Voltage Offset Correction: v_off_ini = -139.668 uV, v_off_fin = -134.587 uV 16:02:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.100 uVs 16:02:20 Integrated Voltage Measurement... 16:02:29 Voltage Offset Correction: v_off_ini = -130.607 uV, v_off_fin = -137.989 uV 16:02:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.958 uVs 16:02:29 Integrated Voltage Measurement... 16:02:38 Voltage Offset Correction: v_off_ini = -126.705 uV, v_off_fin = -121.976 uV 16:02:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.115 uVs 16:02:42 I1Y Average and RMS of Measurements VT = -189.530 +- 2.839 uVs I1Y = -37.906 +- 0.568 uTm 16:02:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:49 Integrated Voltage Measurement... 16:02:58 Voltage Offset Correction: v_off_ini = -124.263 uV, v_off_fin = -119.656 uV 16:02:59 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -69.176 uVs 16:02:59 Integrated Voltage Measurement... 16:03:08 Voltage Offset Correction: v_off_ini = -145.549 uV, v_off_fin = -136.611 uV 16:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.979 uVs 16:03:08 Integrated Voltage Measurement... 16:03:17 Voltage Offset Correction: v_off_ini = -125.165 uV, v_off_fin = -126.398 uV 16:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.638 uVs 16:03:17 Integrated Voltage Measurement... 16:03:26 Voltage Offset Correction: v_off_ini = -139.805 uV, v_off_fin = -143.243 uV 16:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.207 uVs 16:03:26 Integrated Voltage Measurement... 16:03:35 Voltage Offset Correction: v_off_ini = -126.110 uV, v_off_fin = -126.125 uV 16:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.076 uVs 16:03:35 Integrated Voltage Measurement... 16:03:44 Voltage Offset Correction: v_off_ini = -139.274 uV, v_off_fin = -145.106 uV 16:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.166 uVs 16:03:46 I2X Average and RMS of Measurements VT = -75.040 +- 5.226 uVs I2X = 6.903 +- 0.481 uTm^2 16:03:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:54 Integrated Voltage Measurement... 16:04:03 Voltage Offset Correction: v_off_ini = -128.897 uV, v_off_fin = -135.557 uV 16:04:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.525 uVs 16:04:03 Integrated Voltage Measurement... 16:04:12 Voltage Offset Correction: v_off_ini = -146.990 uV, v_off_fin = -122.761 uV 16:04:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.057 uVs 16:04:12 Integrated Voltage Measurement... 16:04:21 Voltage Offset Correction: v_off_ini = -144.153 uV, v_off_fin = -140.535 uV 16:04:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.164 uVs 16:04:21 Integrated Voltage Measurement... 16:04:30 Voltage Offset Correction: v_off_ini = -144.646 uV, v_off_fin = -144.789 uV 16:04:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.653 uVs 16:04:30 Integrated Voltage Measurement... 16:04:39 Voltage Offset Correction: v_off_ini = -147.387 uV, v_off_fin = -136.815 uV 16:04:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.969 uVs 16:04:39 Integrated Voltage Measurement... 16:04:48 Voltage Offset Correction: v_off_ini = -130.012 uV, v_off_fin = -141.118 uV 16:04:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.319 uVs 16:04:50 I2Y Average and RMS of Measurements VT = -201.948 +- 4.443 uVs I2Y = -18.579 +- 0.409 uTm^2 16:05:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:08 Integrated Voltage Measurement... 16:05:17 Voltage Offset Correction: v_off_ini = -145.952 uV, v_off_fin = -126.614 uV 16:05:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.292 uVs 16:05:17 Integrated Voltage Measurement... 16:05:26 Voltage Offset Correction: v_off_ini = -132.776 uV, v_off_fin = -123.393 uV 16:05:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.826 uVs 16:05:26 Integrated Voltage Measurement... 16:05:35 Voltage Offset Correction: v_off_ini = -131.106 uV, v_off_fin = -132.092 uV 16:05:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.158 uVs 16:05:35 Integrated Voltage Measurement... 16:05:44 Voltage Offset Correction: v_off_ini = -125.935 uV, v_off_fin = -123.672 uV 16:05:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.629 uVs 16:05:44 Integrated Voltage Measurement... 16:05:53 Voltage Offset Correction: v_off_ini = -139.323 uV, v_off_fin = -127.007 uV 16:05:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.817 uVs 16:05:53 Integrated Voltage Measurement... 16:06:02 Voltage Offset Correction: v_off_ini = -132.348 uV, v_off_fin = -122.106 uV 16:06:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.774 uVs 16:06:07 I1X Average and RMS of Measurements VT = -51.916 +- 5.366 uVs I1X = 10.383 +- 1.073 uTm 16:06:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:13 Integrated Voltage Measurement... 16:06:22 Voltage Offset Correction: v_off_ini = -129.278 uV, v_off_fin = -147.739 uV 16:06:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.131 uVs 16:06:22 Integrated Voltage Measurement... 16:06:31 Voltage Offset Correction: v_off_ini = -124.018 uV, v_off_fin = -115.208 uV 16:06:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.351 uVs 16:06:31 Integrated Voltage Measurement... 16:06:40 Voltage Offset Correction: v_off_ini = -132.793 uV, v_off_fin = -132.955 uV 16:06:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.421 uVs 16:06:40 Integrated Voltage Measurement... 16:06:49 Voltage Offset Correction: v_off_ini = -123.540 uV, v_off_fin = -106.912 uV 16:06:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.913 uVs 16:06:49 Integrated Voltage Measurement... 16:06:58 Voltage Offset Correction: v_off_ini = -123.118 uV, v_off_fin = -141.853 uV 16:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.266 uVs 16:06:58 Integrated Voltage Measurement... 16:07:07 Voltage Offset Correction: v_off_ini = -130.779 uV, v_off_fin = -126.538 uV 16:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.484 uVs 16:07:12 I1Y Average and RMS of Measurements VT = -207.594 +- 4.446 uVs I1Y = -41.518 +- 0.889 uTm 16:07:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:19 Integrated Voltage Measurement... 16:07:28 Voltage Offset Correction: v_off_ini = -149.312 uV, v_off_fin = -126.070 uV 16:07:28 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -67.528 uVs 16:07:28 Integrated Voltage Measurement... 16:07:37 Voltage Offset Correction: v_off_ini = -148.966 uV, v_off_fin = -158.647 uV 16:07:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.909 uVs 16:07:37 Integrated Voltage Measurement... 16:07:46 Voltage Offset Correction: v_off_ini = -139.269 uV, v_off_fin = -145.041 uV 16:07:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.504 uVs 16:07:46 Integrated Voltage Measurement... 16:07:55 Voltage Offset Correction: v_off_ini = -154.596 uV, v_off_fin = -156.643 uV 16:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.587 uVs 16:07:55 Integrated Voltage Measurement... 16:08:04 Voltage Offset Correction: v_off_ini = -140.969 uV, v_off_fin = -144.769 uV 16:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.737 uVs 16:08:04 Integrated Voltage Measurement... 16:08:13 Voltage Offset Correction: v_off_ini = -152.354 uV, v_off_fin = -147.765 uV 16:08:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.620 uVs 16:08:16 I2X Average and RMS of Measurements VT = -79.648 +- 3.629 uVs I2X = 7.328 +- 0.334 uTm^2 16:08:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:24 Integrated Voltage Measurement... 16:08:33 Voltage Offset Correction: v_off_ini = -125.231 uV, v_off_fin = -139.595 uV 16:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.087 uVs 16:08:33 Integrated Voltage Measurement... 16:08:42 Voltage Offset Correction: v_off_ini = -129.505 uV, v_off_fin = -136.209 uV 16:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.991 uVs 16:08:42 Integrated Voltage Measurement... 16:08:51 Voltage Offset Correction: v_off_ini = -139.688 uV, v_off_fin = -144.125 uV 16:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.787 uVs 16:08:51 Integrated Voltage Measurement... 16:09:00 Voltage Offset Correction: v_off_ini = -129.667 uV, v_off_fin = -129.693 uV 16:09:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.469 uVs 16:09:00 Integrated Voltage Measurement... 16:09:09 Voltage Offset Correction: v_off_ini = -148.108 uV, v_off_fin = -136.271 uV 16:09:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.322 uVs 16:09:09 Integrated Voltage Measurement... 16:09:18 Voltage Offset Correction: v_off_ini = -141.630 uV, v_off_fin = -147.473 uV 16:09:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.110 uVs 16:09:20 I2Y Average and RMS of Measurements VT = -226.628 +- 4.636 uVs I2Y = -20.850 +- 0.427 uTm^2 16:09:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:37 Integrated Voltage Measurement... 16:09:46 Voltage Offset Correction: v_off_ini = -166.229 uV, v_off_fin = -153.106 uV 16:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.029 uVs 16:09:47 Integrated Voltage Measurement... 16:09:55 Voltage Offset Correction: v_off_ini = -147.841 uV, v_off_fin = -152.880 uV 16:09:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.397 uVs 16:09:56 Integrated Voltage Measurement... 16:10:05 Voltage Offset Correction: v_off_ini = -164.699 uV, v_off_fin = -165.798 uV 16:10:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.851 uVs 16:10:05 Integrated Voltage Measurement... 16:10:14 Voltage Offset Correction: v_off_ini = -164.105 uV, v_off_fin = -159.736 uV 16:10:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.975 uVs 16:10:14 Integrated Voltage Measurement... 16:10:23 Voltage Offset Correction: v_off_ini = -152.902 uV, v_off_fin = -152.475 uV 16:10:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.268 uVs 16:10:23 Integrated Voltage Measurement... 16:10:32 Voltage Offset Correction: v_off_ini = -170.300 uV, v_off_fin = -152.706 uV 16:10:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.711 uVs 16:10:36 I1X Average and RMS of Measurements VT = -60.872 +- 5.192 uVs I1X = 12.175 +- 1.038 uTm 16:10:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:43 Integrated Voltage Measurement... 16:10:52 Voltage Offset Correction: v_off_ini = -139.813 uV, v_off_fin = -160.039 uV 16:10:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.991 uVs 16:10:52 Integrated Voltage Measurement... 16:11:01 Voltage Offset Correction: v_off_ini = -145.396 uV, v_off_fin = -128.536 uV 16:11:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.417 uVs 16:11:01 Integrated Voltage Measurement... 16:11:10 Voltage Offset Correction: v_off_ini = -162.538 uV, v_off_fin = -165.334 uV 16:11:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.190 uVs 16:11:10 Integrated Voltage Measurement... 16:11:19 Voltage Offset Correction: v_off_ini = -162.831 uV, v_off_fin = -156.218 uV 16:11:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.030 uVs 16:11:19 Integrated Voltage Measurement... 16:11:28 Voltage Offset Correction: v_off_ini = -153.751 uV, v_off_fin = -159.049 uV 16:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.522 uVs 16:11:28 Integrated Voltage Measurement... 16:11:37 Voltage Offset Correction: v_off_ini = -151.589 uV, v_off_fin = -137.297 uV 16:11:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.052 uVs 16:11:41 I1Y Average and RMS of Measurements VT = -222.534 +- 5.488 uVs I1Y = -44.507 +- 1.098 uTm 16:11:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:48 Integrated Voltage Measurement... 16:11:57 Voltage Offset Correction: v_off_ini = -147.269 uV, v_off_fin = -146.307 uV 16:11:57 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -97.131 uVs 16:11:58 Integrated Voltage Measurement... 16:12:06 Voltage Offset Correction: v_off_ini = -136.693 uV, v_off_fin = -162.370 uV 16:12:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.747 uVs 16:12:07 Integrated Voltage Measurement... 16:12:16 Voltage Offset Correction: v_off_ini = -139.374 uV, v_off_fin = -145.819 uV 16:12:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.196 uVs 16:12:16 Integrated Voltage Measurement... 16:12:25 Voltage Offset Correction: v_off_ini = -151.377 uV, v_off_fin = -161.308 uV 16:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.983 uVs 16:12:25 Integrated Voltage Measurement... 16:12:34 Voltage Offset Correction: v_off_ini = -158.088 uV, v_off_fin = -136.934 uV 16:12:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.414 uVs 16:12:34 Integrated Voltage Measurement... 16:12:43 Voltage Offset Correction: v_off_ini = -155.992 uV, v_off_fin = -148.273 uV 16:12:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.237 uVs 16:12:45 I2X Average and RMS of Measurements VT = -79.285 +- 6.094 uVs I2X = 7.294 +- 0.560 uTm^2 16:12:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:53 Integrated Voltage Measurement... 16:13:02 Voltage Offset Correction: v_off_ini = -161.871 uV, v_off_fin = -166.224 uV 16:13:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.001 uVs 16:13:02 Integrated Voltage Measurement... 16:13:11 Voltage Offset Correction: v_off_ini = -153.295 uV, v_off_fin = -149.965 uV 16:13:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.217 uVs 16:13:11 Integrated Voltage Measurement... 16:13:20 Voltage Offset Correction: v_off_ini = -161.745 uV, v_off_fin = -152.876 uV 16:13:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.309 uVs 16:13:20 Integrated Voltage Measurement... 16:13:29 Voltage Offset Correction: v_off_ini = -164.264 uV, v_off_fin = -167.410 uV 16:13:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.471 uVs 16:13:29 Integrated Voltage Measurement... 16:13:38 Voltage Offset Correction: v_off_ini = -159.642 uV, v_off_fin = -159.275 uV 16:13:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.078 uVs 16:13:38 Integrated Voltage Measurement... 16:13:47 Voltage Offset Correction: v_off_ini = -153.280 uV, v_off_fin = -167.818 uV 16:13:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.674 uVs 16:13:50 I2Y Average and RMS of Measurements VT = -236.625 +- 3.545 uVs I2Y = -21.770 +- 0.326 uTm^2 16:14:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:05 Integrated Voltage Measurement... 16:14:14 Voltage Offset Correction: v_off_ini = -174.211 uV, v_off_fin = -156.721 uV 16:14:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -55.386 uVs 16:14:14 Integrated Voltage Measurement... 16:14:23 Voltage Offset Correction: v_off_ini = -148.996 uV, v_off_fin = -159.618 uV 16:14:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.385 uVs 16:14:23 Integrated Voltage Measurement... 16:14:32 Voltage Offset Correction: v_off_ini = -163.528 uV, v_off_fin = -173.161 uV 16:14:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.084 uVs 16:14:32 Integrated Voltage Measurement... 16:14:41 Voltage Offset Correction: v_off_ini = -165.274 uV, v_off_fin = -159.234 uV 16:14:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.750 uVs 16:14:41 Integrated Voltage Measurement... 16:14:50 Voltage Offset Correction: v_off_ini = -173.872 uV, v_off_fin = -172.710 uV 16:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.448 uVs 16:14:50 Integrated Voltage Measurement... 16:14:59 Voltage Offset Correction: v_off_ini = -179.777 uV, v_off_fin = -174.558 uV 16:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.266 uVs 16:15:03 I1X Average and RMS of Measurements VT = -65.553 +- 6.337 uVs I1X = 13.111 +- 1.267 uTm 16:15:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:10 Integrated Voltage Measurement... 16:15:19 Voltage Offset Correction: v_off_ini = -164.798 uV, v_off_fin = -187.991 uV 16:15:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.828 uVs 16:15:19 Integrated Voltage Measurement... 16:15:28 Voltage Offset Correction: v_off_ini = -177.121 uV, v_off_fin = -161.039 uV 16:15:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.117 uVs 16:15:28 Integrated Voltage Measurement... 16:15:37 Voltage Offset Correction: v_off_ini = -162.809 uV, v_off_fin = -172.051 uV 16:15:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.174 uVs 16:15:37 Integrated Voltage Measurement... 16:15:46 Voltage Offset Correction: v_off_ini = -144.321 uV, v_off_fin = -143.636 uV 16:15:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.590 uVs 16:15:46 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = -162.894 uV, v_off_fin = -166.139 uV 16:15:55 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -231.540 uVs 16:15:55 Integrated Voltage Measurement... 16:16:04 Voltage Offset Correction: v_off_ini = -160.278 uV, v_off_fin = -156.805 uV 16:16:04 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 242.955 uVs 16:16:08 I1Y Average and RMS of Measurements VT = -232.701 +- 4.609 uVs I1Y = -46.537 +- 0.919 uTm 16:16:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:16 Integrated Voltage Measurement... 16:16:25 Voltage Offset Correction: v_off_ini = -149.583 uV, v_off_fin = -134.104 uV 16:16:25 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.783 uVs 16:16:25 Integrated Voltage Measurement... 16:16:34 Voltage Offset Correction: v_off_ini = -139.104 uV, v_off_fin = -149.169 uV 16:16:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.852 uVs 16:16:34 Integrated Voltage Measurement... 16:16:43 Voltage Offset Correction: v_off_ini = -152.914 uV, v_off_fin = -147.355 uV 16:16:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.225 uVs 16:16:43 Integrated Voltage Measurement... 16:16:52 Voltage Offset Correction: v_off_ini = -165.898 uV, v_off_fin = -171.903 uV 16:16:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.947 uVs 16:16:52 Integrated Voltage Measurement... 16:17:01 Voltage Offset Correction: v_off_ini = -153.509 uV, v_off_fin = -139.018 uV 16:17:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.086 uVs 16:17:01 Integrated Voltage Measurement... 16:17:10 Voltage Offset Correction: v_off_ini = -145.792 uV, v_off_fin = -151.562 uV 16:17:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.734 uVs 16:17:12 I2X Average and RMS of Measurements VT = -96.105 +- 5.254 uVs I2X = 8.841 +- 0.483 uTm^2 16:17:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:20 Integrated Voltage Measurement... 16:17:29 Voltage Offset Correction: v_off_ini = -142.199 uV, v_off_fin = -140.919 uV 16:17:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.480 uVs 16:17:29 Integrated Voltage Measurement... 16:17:38 Voltage Offset Correction: v_off_ini = -144.917 uV, v_off_fin = -131.560 uV 16:17:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 234.697 uVs 16:17:38 Integrated Voltage Measurement... 16:17:47 Voltage Offset Correction: v_off_ini = -141.135 uV, v_off_fin = -156.525 uV 16:17:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.297 uVs 16:17:47 Integrated Voltage Measurement... 16:17:56 Voltage Offset Correction: v_off_ini = -134.618 uV, v_off_fin = -149.049 uV 16:17:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.565 uVs 16:17:56 Integrated Voltage Measurement... 16:18:05 Voltage Offset Correction: v_off_ini = -157.753 uV, v_off_fin = -147.709 uV 16:18:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.882 uVs 16:18:05 Integrated Voltage Measurement... 16:18:14 Voltage Offset Correction: v_off_ini = -152.768 uV, v_off_fin = -161.533 uV 16:18:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.542 uVs 16:18:17 I2Y Average and RMS of Measurements VT = -239.244 +- 19.585 uVs I2Y = -22.011 +- 1.802 uTm^2 16:18:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm