SLAC Magnetic Measurements Date: 04-22-2025 Time: 11:24:17 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE-SXPS_16348 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 4 Measurement Device: Operator: YL Comment: Tuning 11:24:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:27 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:24:28 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:24:30 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:24:32 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:24:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:51 Integrated Voltage Measurement... 11:25:00 Voltage Offset Correction: v_off_ini = -372.740 uV, v_off_fin = -368.617 uV 11:25:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.945 uVs 11:25:00 Integrated Voltage Measurement... 11:25:09 Voltage Offset Correction: v_off_ini = -370.707 uV, v_off_fin = -363.357 uV 11:25:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.856 uVs 11:25:09 Integrated Voltage Measurement... 11:25:18 Voltage Offset Correction: v_off_ini = -362.181 uV, v_off_fin = -371.172 uV 11:25:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.620 uVs 11:25:18 Integrated Voltage Measurement... 11:25:27 Voltage Offset Correction: v_off_ini = -363.219 uV, v_off_fin = -364.988 uV 11:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.103 uVs 11:25:28 Integrated Voltage Measurement... 11:25:36 Voltage Offset Correction: v_off_ini = -371.805 uV, v_off_fin = -371.193 uV 11:25:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.768 uVs 11:25:37 Integrated Voltage Measurement... 11:25:45 Voltage Offset Correction: v_off_ini = -361.148 uV, v_off_fin = -360.631 uV 11:25:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.040 uVs 11:25:50 I1X Average and RMS of Measurements VT = -54.222 +- 10.183 uVs I1X = 10.844 +- 2.037 uTm 11:25:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:57 Integrated Voltage Measurement... 11:26:05 Voltage Offset Correction: v_off_ini = -375.735 uV, v_off_fin = -383.562 uV 11:26:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.434 uVs 11:26:06 Integrated Voltage Measurement... 11:26:14 Voltage Offset Correction: v_off_ini = -356.842 uV, v_off_fin = -345.097 uV 11:26:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.331 uVs 11:26:15 Integrated Voltage Measurement... 11:26:23 Voltage Offset Correction: v_off_ini = -371.223 uV, v_off_fin = -373.047 uV 11:26:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.623 uVs 11:26:24 Integrated Voltage Measurement... 11:26:32 Voltage Offset Correction: v_off_ini = -370.117 uV, v_off_fin = -363.602 uV 11:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 296.425 uVs 11:26:33 Integrated Voltage Measurement... 11:26:41 Voltage Offset Correction: v_off_ini = -372.614 uV, v_off_fin = -377.500 uV 11:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.460 uVs 11:26:42 Integrated Voltage Measurement... 11:26:50 Voltage Offset Correction: v_off_ini = -370.424 uV, v_off_fin = -347.476 uV 11:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.917 uVs 11:26:55 I1Y Average and RMS of Measurements VT = -283.198 +- 6.241 uVs I1Y = -56.640 +- 1.248 uTm 11:27:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:02 Integrated Voltage Measurement... 11:27:11 Voltage Offset Correction: v_off_ini = -355.109 uV, v_off_fin = -341.833 uV 11:27:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.472 uVs 11:27:12 Integrated Voltage Measurement... 11:27:20 Voltage Offset Correction: v_off_ini = -358.589 uV, v_off_fin = -352.866 uV 11:27:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.789 uVs 11:27:21 Integrated Voltage Measurement... 11:27:30 Voltage Offset Correction: v_off_ini = -368.443 uV, v_off_fin = -362.272 uV 11:27:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.402 uVs 11:27:30 Integrated Voltage Measurement... 11:27:39 Voltage Offset Correction: v_off_ini = -351.671 uV, v_off_fin = -351.667 uV 11:27:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.004 uVs 11:27:39 Integrated Voltage Measurement... 11:27:48 Voltage Offset Correction: v_off_ini = -360.822 uV, v_off_fin = -362.070 uV 11:27:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.856 uVs 11:27:48 Integrated Voltage Measurement... 11:27:57 Voltage Offset Correction: v_off_ini = -367.293 uV, v_off_fin = -361.411 uV 11:27:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.618 uVs 11:27:59 I2X Average and RMS of Measurements VT = -62.523 +- 9.629 uVs I2X = 5.752 +- 0.886 uTm^2 11:28:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:07 Integrated Voltage Measurement... 11:28:16 Voltage Offset Correction: v_off_ini = -388.041 uV, v_off_fin = -371.183 uV 11:28:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.333 uVs 11:28:16 Integrated Voltage Measurement... 11:28:25 Voltage Offset Correction: v_off_ini = -370.577 uV, v_off_fin = -359.389 uV 11:28:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.106 uVs 11:28:25 Integrated Voltage Measurement... 11:28:34 Voltage Offset Correction: v_off_ini = -369.334 uV, v_off_fin = -369.722 uV 11:28:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.397 uVs 11:28:34 Integrated Voltage Measurement... 11:28:43 Voltage Offset Correction: v_off_ini = -385.664 uV, v_off_fin = -368.547 uV 11:28:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 257.174 uVs 11:28:43 Integrated Voltage Measurement... 11:28:52 Voltage Offset Correction: v_off_ini = -384.227 uV, v_off_fin = -382.277 uV 11:28:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -275.117 uVs 11:28:52 Integrated Voltage Measurement... 11:29:01 Voltage Offset Correction: v_off_ini = -371.291 uV, v_off_fin = -383.828 uV 11:29:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 237.888 uVs 11:29:03 I2Y Average and RMS of Measurements VT = -258.669 +- 4.386 uVs I2Y = -23.799 +- 0.404 uTm^2 11:29:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:17 Integrated Voltage Measurement... 11:29:26 Voltage Offset Correction: v_off_ini = -379.533 uV, v_off_fin = -380.676 uV 11:29:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.471 uVs 11:29:26 Integrated Voltage Measurement... 11:29:35 Voltage Offset Correction: v_off_ini = -375.192 uV, v_off_fin = -383.535 uV 11:29:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.671 uVs 11:29:35 Integrated Voltage Measurement... 11:29:44 Voltage Offset Correction: v_off_ini = -394.093 uV, v_off_fin = -401.362 uV 11:29:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.083 uVs 11:29:45 Integrated Voltage Measurement... 11:29:53 Voltage Offset Correction: v_off_ini = -375.872 uV, v_off_fin = -382.531 uV 11:29:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.528 uVs 11:29:54 Integrated Voltage Measurement... 11:30:02 Voltage Offset Correction: v_off_ini = -392.340 uV, v_off_fin = -385.796 uV 11:30:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.675 uVs 11:30:03 Integrated Voltage Measurement... 11:30:11 Voltage Offset Correction: v_off_ini = -385.088 uV, v_off_fin = -368.894 uV 11:30:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.143 uVs 11:30:16 I1X Average and RMS of Measurements VT = -53.429 +- 1.885 uVs I1X = 10.686 +- 0.377 uTm 11:30:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:23 Integrated Voltage Measurement... 11:30:31 Voltage Offset Correction: v_off_ini = -391.226 uV, v_off_fin = -415.872 uV 11:30:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.527 uVs 11:30:32 Integrated Voltage Measurement... 11:30:40 Voltage Offset Correction: v_off_ini = -407.387 uV, v_off_fin = -395.751 uV 11:30:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.819 uVs 11:30:41 Integrated Voltage Measurement... 11:30:50 Voltage Offset Correction: v_off_ini = -415.878 uV, v_off_fin = -409.565 uV 11:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.962 uVs 11:30:50 Integrated Voltage Measurement... 11:30:59 Voltage Offset Correction: v_off_ini = -398.867 uV, v_off_fin = -393.034 uV 11:30:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.382 uVs 11:30:59 Integrated Voltage Measurement... 11:31:08 Voltage Offset Correction: v_off_ini = -393.645 uV, v_off_fin = -406.715 uV 11:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.475 uVs 11:31:08 Integrated Voltage Measurement... 11:31:17 Voltage Offset Correction: v_off_ini = -390.870 uV, v_off_fin = -386.798 uV 11:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.955 uVs 11:31:21 I1Y Average and RMS of Measurements VT = -261.854 +- 2.257 uVs I1Y = -52.371 +- 0.451 uTm 11:31:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:28 Integrated Voltage Measurement... 11:31:37 Voltage Offset Correction: v_off_ini = -408.739 uV, v_off_fin = -399.907 uV 11:31:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.838 uVs 11:31:38 Integrated Voltage Measurement... 11:31:47 Voltage Offset Correction: v_off_ini = -408.484 uV, v_off_fin = -410.878 uV 11:31:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.464 uVs 11:31:47 Integrated Voltage Measurement... 11:31:56 Voltage Offset Correction: v_off_ini = -412.515 uV, v_off_fin = -407.338 uV 11:31:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.963 uVs 11:31:56 Integrated Voltage Measurement... 11:32:05 Voltage Offset Correction: v_off_ini = -409.057 uV, v_off_fin = -414.953 uV 11:32:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.002 uVs 11:32:05 Integrated Voltage Measurement... 11:32:14 Voltage Offset Correction: v_off_ini = -394.345 uV, v_off_fin = -391.134 uV 11:32:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.403 uVs 11:32:14 Integrated Voltage Measurement... 11:32:23 Voltage Offset Correction: v_off_ini = -413.496 uV, v_off_fin = -415.115 uV 11:32:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.730 uVs 11:32:25 I2X Average and RMS of Measurements VT = -65.233 +- 7.374 uVs I2X = 6.001 +- 0.678 uTm^2 11:32:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:33 Integrated Voltage Measurement... 11:32:42 Voltage Offset Correction: v_off_ini = -397.025 uV, v_off_fin = -402.196 uV 11:32:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.721 uVs 11:32:42 Integrated Voltage Measurement... 11:32:51 Voltage Offset Correction: v_off_ini = -389.146 uV, v_off_fin = -397.332 uV 11:32:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.748 uVs 11:32:51 Integrated Voltage Measurement... 11:33:00 Voltage Offset Correction: v_off_ini = -387.922 uV, v_off_fin = -397.860 uV 11:33:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.508 uVs 11:33:00 Integrated Voltage Measurement... 11:33:09 Voltage Offset Correction: v_off_ini = -401.969 uV, v_off_fin = -396.451 uV 11:33:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.191 uVs 11:33:09 Integrated Voltage Measurement... 11:33:18 Voltage Offset Correction: v_off_ini = -398.946 uV, v_off_fin = -398.624 uV 11:33:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.114 uVs 11:33:18 Integrated Voltage Measurement... 11:33:27 Voltage Offset Correction: v_off_ini = -413.199 uV, v_off_fin = -410.057 uV 11:33:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.949 uVs 11:33:30 I2Y Average and RMS of Measurements VT = -261.705 +- 2.501 uVs I2Y = -24.077 +- 0.230 uTm^2 11:33:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:44 Integrated Voltage Measurement... 11:33:52 Voltage Offset Correction: v_off_ini = -415.637 uV, v_off_fin = -411.718 uV 11:33:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.174 uVs 11:33:53 Integrated Voltage Measurement... 11:34:02 Voltage Offset Correction: v_off_ini = -409.238 uV, v_off_fin = -402.303 uV 11:34:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.629 uVs 11:34:02 Integrated Voltage Measurement... 11:34:11 Voltage Offset Correction: v_off_ini = -421.451 uV, v_off_fin = -411.228 uV 11:34:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.035 uVs 11:34:11 Integrated Voltage Measurement... 11:34:20 Voltage Offset Correction: v_off_ini = -411.539 uV, v_off_fin = -414.149 uV 11:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.474 uVs 11:34:20 Integrated Voltage Measurement... 11:34:29 Voltage Offset Correction: v_off_ini = -405.942 uV, v_off_fin = -416.357 uV 11:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.250 uVs 11:34:29 Integrated Voltage Measurement... 11:34:38 Voltage Offset Correction: v_off_ini = -414.135 uV, v_off_fin = -397.438 uV 11:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.469 uVs 11:34:42 I1X Average and RMS of Measurements VT = -40.172 +- 10.622 uVs I1X = 8.034 +- 2.124 uTm 11:34:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:34:49 Integrated Voltage Measurement... 11:34:58 Voltage Offset Correction: v_off_ini = -414.720 uV, v_off_fin = -420.016 uV 11:34:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.703 uVs 11:34:58 Integrated Voltage Measurement... 11:35:07 Voltage Offset Correction: v_off_ini = -415.202 uV, v_off_fin = -401.748 uV 11:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.149 uVs 11:35:07 Integrated Voltage Measurement... 11:35:16 Voltage Offset Correction: v_off_ini = -418.757 uV, v_off_fin = -421.170 uV 11:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.332 uVs 11:35:16 Integrated Voltage Measurement... 11:35:25 Voltage Offset Correction: v_off_ini = -415.573 uV, v_off_fin = -389.127 uV 11:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.078 uVs 11:35:25 Integrated Voltage Measurement... 11:35:34 Voltage Offset Correction: v_off_ini = -407.276 uV, v_off_fin = -427.589 uV 11:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.234 uVs 11:35:34 Integrated Voltage Measurement... 11:35:43 Voltage Offset Correction: v_off_ini = -402.888 uV, v_off_fin = -395.836 uV 11:35:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.699 uVs 11:35:47 I1Y Average and RMS of Measurements VT = -232.866 +- 5.031 uVs I1Y = -46.573 +- 1.006 uTm 11:35:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:55 Integrated Voltage Measurement... 11:36:04 Voltage Offset Correction: v_off_ini = -411.743 uV, v_off_fin = -411.272 uV 11:36:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -72.795 uVs 11:36:04 Integrated Voltage Measurement... 11:36:13 Voltage Offset Correction: v_off_ini = -415.591 uV, v_off_fin = -409.228 uV 11:36:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.890 uVs 11:36:13 Integrated Voltage Measurement... 11:36:22 Voltage Offset Correction: v_off_ini = -414.140 uV, v_off_fin = -401.579 uV 11:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.156 uVs 11:36:22 Integrated Voltage Measurement... 11:36:31 Voltage Offset Correction: v_off_ini = -407.787 uV, v_off_fin = -427.234 uV 11:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.308 uVs 11:36:31 Integrated Voltage Measurement... 11:36:40 Voltage Offset Correction: v_off_ini = -420.109 uV, v_off_fin = -408.896 uV 11:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.063 uVs 11:36:40 Integrated Voltage Measurement... 11:36:49 Voltage Offset Correction: v_off_ini = -405.575 uV, v_off_fin = -421.886 uV 11:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.264 uVs 11:36:51 I2X Average and RMS of Measurements VT = -69.580 +- 3.604 uVs I2X = 6.401 +- 0.332 uTm^2 11:36:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:59 Integrated Voltage Measurement... 11:37:08 Voltage Offset Correction: v_off_ini = -414.503 uV, v_off_fin = -408.311 uV 11:37:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.475 uVs 11:37:08 Integrated Voltage Measurement... 11:37:17 Voltage Offset Correction: v_off_ini = -401.867 uV, v_off_fin = -406.577 uV 11:37:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.614 uVs 11:37:17 Integrated Voltage Measurement... 11:37:26 Voltage Offset Correction: v_off_ini = -401.156 uV, v_off_fin = -412.436 uV 11:37:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.922 uVs 11:37:26 Integrated Voltage Measurement... 11:37:35 Voltage Offset Correction: v_off_ini = -414.623 uV, v_off_fin = -396.960 uV 11:37:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.114 uVs 11:37:35 Integrated Voltage Measurement... 11:37:44 Voltage Offset Correction: v_off_ini = -403.571 uV, v_off_fin = -415.707 uV 11:37:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.931 uVs 11:37:44 Integrated Voltage Measurement... 11:37:53 Voltage Offset Correction: v_off_ini = -399.221 uV, v_off_fin = -408.005 uV 11:37:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.925 uVs 11:37:56 I2Y Average and RMS of Measurements VT = -242.163 +- 3.026 uVs I2Y = -22.279 +- 0.278 uTm^2 11:38:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:10 Integrated Voltage Measurement... 11:38:19 Voltage Offset Correction: v_off_ini = -409.048 uV, v_off_fin = -421.220 uV 11:38:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.909 uVs 11:38:19 Integrated Voltage Measurement... 11:38:28 Voltage Offset Correction: v_off_ini = -402.247 uV, v_off_fin = -393.947 uV 11:38:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.393 uVs 11:38:28 Integrated Voltage Measurement... 11:38:37 Voltage Offset Correction: v_off_ini = -401.132 uV, v_off_fin = -424.513 uV 11:38:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.296 uVs 11:38:37 Integrated Voltage Measurement... 11:38:46 Voltage Offset Correction: v_off_ini = -419.075 uV, v_off_fin = -420.706 uV 11:38:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.678 uVs 11:38:46 Integrated Voltage Measurement... 11:38:55 Voltage Offset Correction: v_off_ini = -416.208 uV, v_off_fin = -426.541 uV 11:38:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.057 uVs 11:38:55 Integrated Voltage Measurement... 11:39:04 Voltage Offset Correction: v_off_ini = -405.205 uV, v_off_fin = -414.076 uV 11:39:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.318 uVs 11:39:08 I1X Average and RMS of Measurements VT = -40.942 +- 8.266 uVs I1X = 8.188 +- 1.653 uTm 11:39:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:15 Integrated Voltage Measurement... 11:39:24 Voltage Offset Correction: v_off_ini = -414.196 uV, v_off_fin = -444.634 uV 11:39:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.019 uVs 11:39:24 Integrated Voltage Measurement... 11:39:33 Voltage Offset Correction: v_off_ini = -417.714 uV, v_off_fin = -410.472 uV 11:39:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.107 uVs 11:39:33 Integrated Voltage Measurement... 11:39:42 Voltage Offset Correction: v_off_ini = -417.345 uV, v_off_fin = -433.897 uV 11:39:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.205 uVs 11:39:42 Integrated Voltage Measurement... 11:39:51 Voltage Offset Correction: v_off_ini = -414.964 uV, v_off_fin = -415.165 uV 11:39:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.868 uVs 11:39:51 Integrated Voltage Measurement... 11:40:00 Voltage Offset Correction: v_off_ini = -417.944 uV, v_off_fin = -452.664 uV 11:40:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.079 uVs 11:40:00 Integrated Voltage Measurement... 11:40:09 Voltage Offset Correction: v_off_ini = -415.423 uV, v_off_fin = -412.405 uV 11:40:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.588 uVs 11:40:13 I1Y Average and RMS of Measurements VT = -221.311 +- 7.862 uVs I1Y = -44.263 +- 1.572 uTm 11:40:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:21 Integrated Voltage Measurement... 11:40:30 Voltage Offset Correction: v_off_ini = -404.969 uV, v_off_fin = -415.205 uV 11:40:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -42.372 uVs 11:40:30 Integrated Voltage Measurement... 11:40:39 Voltage Offset Correction: v_off_ini = -417.329 uV, v_off_fin = -422.604 uV 11:40:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.493 uVs 11:40:39 Integrated Voltage Measurement... 11:40:48 Voltage Offset Correction: v_off_ini = -409.477 uV, v_off_fin = -401.249 uV 11:40:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.037 uVs 11:40:48 Integrated Voltage Measurement... 11:40:57 Voltage Offset Correction: v_off_ini = -412.599 uV, v_off_fin = -422.143 uV 11:40:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.223 uVs 11:40:57 Integrated Voltage Measurement... 11:41:06 Voltage Offset Correction: v_off_ini = -416.078 uV, v_off_fin = -425.568 uV 11:41:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.130 uVs 11:41:06 Integrated Voltage Measurement... 11:41:15 Voltage Offset Correction: v_off_ini = -420.645 uV, v_off_fin = -414.890 uV 11:41:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.124 uVs 11:41:17 I2X Average and RMS of Measurements VT = -54.230 +- 6.753 uVs I2X = 4.989 +- 0.621 uTm^2 11:41:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:25 Integrated Voltage Measurement... 11:41:34 Voltage Offset Correction: v_off_ini = -410.688 uV, v_off_fin = -419.567 uV 11:41:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.955 uVs 11:41:34 Integrated Voltage Measurement... 11:41:43 Voltage Offset Correction: v_off_ini = -413.661 uV, v_off_fin = -421.740 uV 11:41:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.828 uVs 11:41:43 Integrated Voltage Measurement... 11:41:52 Voltage Offset Correction: v_off_ini = -411.047 uV, v_off_fin = -417.672 uV 11:41:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.606 uVs 11:41:52 Integrated Voltage Measurement... 11:42:01 Voltage Offset Correction: v_off_ini = -434.961 uV, v_off_fin = -424.945 uV 11:42:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.680 uVs 11:42:01 Integrated Voltage Measurement... 11:42:10 Voltage Offset Correction: v_off_ini = -431.043 uV, v_off_fin = -428.613 uV 11:42:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.450 uVs 11:42:10 Integrated Voltage Measurement... 11:42:19 Voltage Offset Correction: v_off_ini = -419.852 uV, v_off_fin = -427.903 uV 11:42:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.337 uVs 11:42:22 I2Y Average and RMS of Measurements VT = -231.143 +- 10.326 uVs I2Y = -21.265 +- 0.950 uTm^2 11:42:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:36 Integrated Voltage Measurement... 11:42:45 Voltage Offset Correction: v_off_ini = -437.639 uV, v_off_fin = -435.125 uV 11:42:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.485 uVs 11:42:45 Integrated Voltage Measurement... 11:42:54 Voltage Offset Correction: v_off_ini = -447.467 uV, v_off_fin = -407.119 uV 11:42:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.362 uVs 11:42:54 Integrated Voltage Measurement... 11:43:03 Voltage Offset Correction: v_off_ini = -427.366 uV, v_off_fin = -427.857 uV 11:43:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.366 uVs 11:43:03 Integrated Voltage Measurement... 11:43:12 Voltage Offset Correction: v_off_ini = -419.422 uV, v_off_fin = -440.528 uV 11:43:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.965 uVs 11:43:12 Integrated Voltage Measurement... 11:43:21 Voltage Offset Correction: v_off_ini = -432.854 uV, v_off_fin = -432.501 uV 11:43:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.827 uVs 11:43:21 Integrated Voltage Measurement... 11:43:30 Voltage Offset Correction: v_off_ini = -418.167 uV, v_off_fin = -423.207 uV 11:43:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.909 uVs 11:43:34 I1X Average and RMS of Measurements VT = -52.985 +- 4.270 uVs I1X = 10.597 +- 0.854 uTm 11:43:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:43:41 Integrated Voltage Measurement... 11:43:50 Voltage Offset Correction: v_off_ini = -424.127 uV, v_off_fin = -451.777 uV 11:43:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.517 uVs 11:43:50 Integrated Voltage Measurement... 11:43:59 Voltage Offset Correction: v_off_ini = -436.673 uV, v_off_fin = -414.178 uV 11:43:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.914 uVs 11:43:59 Integrated Voltage Measurement... 11:44:08 Voltage Offset Correction: v_off_ini = -419.217 uV, v_off_fin = -449.550 uV 11:44:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.044 uVs 11:44:08 Integrated Voltage Measurement... 11:44:17 Voltage Offset Correction: v_off_ini = -413.104 uV, v_off_fin = -409.835 uV 11:44:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.417 uVs 11:44:17 Integrated Voltage Measurement... 11:44:26 Voltage Offset Correction: v_off_ini = -434.320 uV, v_off_fin = -454.054 uV 11:44:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.240 uVs 11:44:26 Integrated Voltage Measurement... 11:44:35 Voltage Offset Correction: v_off_ini = -425.704 uV, v_off_fin = -401.519 uV 11:44:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.140 uVs 11:44:39 I1Y Average and RMS of Measurements VT = -210.545 +- 6.498 uVs I1Y = -42.109 +- 1.300 uTm 11:44:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:47 Integrated Voltage Measurement... 11:44:56 Voltage Offset Correction: v_off_ini = -413.209 uV, v_off_fin = -419.113 uV 11:44:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -67.421 uVs 11:44:56 Integrated Voltage Measurement... 11:45:05 Voltage Offset Correction: v_off_ini = -403.859 uV, v_off_fin = -418.056 uV 11:45:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.463 uVs 11:45:05 Integrated Voltage Measurement... 11:45:14 Voltage Offset Correction: v_off_ini = -419.056 uV, v_off_fin = -400.937 uV 11:45:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.532 uVs 11:45:14 Integrated Voltage Measurement... 11:45:23 Voltage Offset Correction: v_off_ini = -415.900 uV, v_off_fin = -418.555 uV 11:45:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.131 uVs 11:45:23 Integrated Voltage Measurement... 11:45:32 Voltage Offset Correction: v_off_ini = -400.316 uV, v_off_fin = -392.893 uV 11:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.603 uVs 11:45:32 Integrated Voltage Measurement... 11:45:41 Voltage Offset Correction: v_off_ini = -404.041 uV, v_off_fin = -405.284 uV 11:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.214 uVs 11:45:43 I2X Average and RMS of Measurements VT = -63.394 +- 4.051 uVs I2X = 5.832 +- 0.373 uTm^2 11:45:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:51 Integrated Voltage Measurement... 11:46:00 Voltage Offset Correction: v_off_ini = -412.047 uV, v_off_fin = -416.359 uV 11:46:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.783 uVs 11:46:00 Integrated Voltage Measurement... 11:46:09 Voltage Offset Correction: v_off_ini = -412.604 uV, v_off_fin = -401.964 uV 11:46:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.102 uVs 11:46:09 Integrated Voltage Measurement... 11:46:18 Voltage Offset Correction: v_off_ini = -407.272 uV, v_off_fin = -411.661 uV 11:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.537 uVs 11:46:18 Integrated Voltage Measurement... 11:46:27 Voltage Offset Correction: v_off_ini = -404.164 uV, v_off_fin = -399.695 uV 11:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.871 uVs 11:46:27 Integrated Voltage Measurement... 11:46:36 Voltage Offset Correction: v_off_ini = -408.198 uV, v_off_fin = -400.940 uV 11:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.395 uVs 11:46:36 Integrated Voltage Measurement... 11:46:45 Voltage Offset Correction: v_off_ini = -395.077 uV, v_off_fin = -395.277 uV 11:46:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 225.945 uVs 11:46:48 I2Y Average and RMS of Measurements VT = -221.272 +- 0.522 uVs I2Y = -20.357 +- 0.048 uTm^2 11:46:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:01 Integrated Voltage Measurement... 11:47:10 Voltage Offset Correction: v_off_ini = -396.954 uV, v_off_fin = -409.418 uV 11:47:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.452 uVs 11:47:10 Integrated Voltage Measurement... 11:47:19 Voltage Offset Correction: v_off_ini = -396.659 uV, v_off_fin = -397.027 uV 11:47:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.556 uVs 11:47:20 Integrated Voltage Measurement... 11:47:28 Voltage Offset Correction: v_off_ini = -398.227 uV, v_off_fin = -393.093 uV 11:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.051 uVs 11:47:29 Integrated Voltage Measurement... 11:47:37 Voltage Offset Correction: v_off_ini = -398.377 uV, v_off_fin = -388.644 uV 11:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.233 uVs 11:47:38 Integrated Voltage Measurement... 11:47:47 Voltage Offset Correction: v_off_ini = -381.084 uV, v_off_fin = -395.830 uV 11:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.181 uVs 11:47:47 Integrated Voltage Measurement... 11:47:56 Voltage Offset Correction: v_off_ini = -386.415 uV, v_off_fin = -402.842 uV 11:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.249 uVs 11:48:00 I1X Average and RMS of Measurements VT = -45.287 +- 2.022 uVs I1X = 9.057 +- 0.404 uTm 11:48:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:07 Integrated Voltage Measurement... 11:48:15 Voltage Offset Correction: v_off_ini = -380.937 uV, v_off_fin = -401.150 uV 11:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.499 uVs 11:48:16 Integrated Voltage Measurement... 11:48:24 Voltage Offset Correction: v_off_ini = -393.758 uV, v_off_fin = -383.619 uV 11:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.176 uVs 11:48:25 Integrated Voltage Measurement... 11:48:33 Voltage Offset Correction: v_off_ini = -386.582 uV, v_off_fin = -413.027 uV 11:48:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.407 uVs 11:48:34 Integrated Voltage Measurement... 11:48:42 Voltage Offset Correction: v_off_ini = -396.957 uV, v_off_fin = -384.984 uV 11:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.812 uVs 11:48:43 Integrated Voltage Measurement... 11:48:51 Voltage Offset Correction: v_off_ini = -403.769 uV, v_off_fin = -402.426 uV 11:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.814 uVs 11:48:52 Integrated Voltage Measurement... 11:49:00 Voltage Offset Correction: v_off_ini = -383.386 uV, v_off_fin = -385.105 uV 11:49:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.805 uVs 11:49:05 I1Y Average and RMS of Measurements VT = -205.585 +- 4.580 uVs I1Y = -41.117 +- 0.916 uTm 11:49:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:12 Integrated Voltage Measurement... 11:49:21 Voltage Offset Correction: v_off_ini = -391.671 uV, v_off_fin = -364.111 uV 11:49:21 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -47.924 uVs 11:49:21 Integrated Voltage Measurement... 11:49:30 Voltage Offset Correction: v_off_ini = -375.164 uV, v_off_fin = -376.166 uV 11:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.443 uVs 11:49:31 Integrated Voltage Measurement... 11:49:40 Voltage Offset Correction: v_off_ini = -364.532 uV, v_off_fin = -366.844 uV 11:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.216 uVs 11:49:40 Integrated Voltage Measurement... 11:49:49 Voltage Offset Correction: v_off_ini = -379.218 uV, v_off_fin = -384.155 uV 11:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.699 uVs 11:49:49 Integrated Voltage Measurement... 11:49:58 Voltage Offset Correction: v_off_ini = -376.553 uV, v_off_fin = -374.211 uV 11:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.217 uVs 11:49:58 Integrated Voltage Measurement... 11:50:07 Voltage Offset Correction: v_off_ini = -377.989 uV, v_off_fin = -382.911 uV 11:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.264 uVs 11:50:09 I2X Average and RMS of Measurements VT = -55.460 +- 3.181 uVs I2X = 5.102 +- 0.293 uTm^2 11:50:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:17 Integrated Voltage Measurement... 11:50:26 Voltage Offset Correction: v_off_ini = -394.394 uV, v_off_fin = -379.512 uV 11:50:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.459 uVs 11:50:26 Integrated Voltage Measurement... 11:50:35 Voltage Offset Correction: v_off_ini = -385.542 uV, v_off_fin = -377.442 uV 11:50:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.697 uVs 11:50:35 Integrated Voltage Measurement... 11:50:44 Voltage Offset Correction: v_off_ini = -384.508 uV, v_off_fin = -396.368 uV 11:50:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.928 uVs 11:50:44 Integrated Voltage Measurement... 11:50:53 Voltage Offset Correction: v_off_ini = -363.604 uV, v_off_fin = -367.143 uV 11:50:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.202 uVs 11:50:53 Integrated Voltage Measurement... 11:51:02 Voltage Offset Correction: v_off_ini = -366.595 uV, v_off_fin = -370.704 uV 11:51:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.629 uVs 11:51:02 Integrated Voltage Measurement... 11:51:11 Voltage Offset Correction: v_off_ini = -381.570 uV, v_off_fin = -372.932 uV 11:51:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.340 uVs 11:51:13 I2Y Average and RMS of Measurements VT = -222.543 +- 8.751 uVs I2Y = -20.474 +- 0.805 uTm^2 11:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:27 Integrated Voltage Measurement... 11:51:36 Voltage Offset Correction: v_off_ini = -358.825 uV, v_off_fin = -369.615 uV 11:51:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -41.206 uVs 11:51:36 Integrated Voltage Measurement... 11:51:45 Voltage Offset Correction: v_off_ini = -362.943 uV, v_off_fin = -373.396 uV 11:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.552 uVs 11:51:45 Integrated Voltage Measurement... 11:51:54 Voltage Offset Correction: v_off_ini = -364.287 uV, v_off_fin = -386.230 uV 11:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.993 uVs 11:51:54 Integrated Voltage Measurement... 11:52:03 Voltage Offset Correction: v_off_ini = -365.278 uV, v_off_fin = -374.973 uV 11:52:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.184 uVs 11:52:03 Integrated Voltage Measurement... 11:52:12 Voltage Offset Correction: v_off_ini = -374.515 uV, v_off_fin = -391.035 uV 11:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.618 uVs 11:52:12 Integrated Voltage Measurement... 11:52:21 Voltage Offset Correction: v_off_ini = -372.207 uV, v_off_fin = -379.426 uV 11:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.848 uVs 11:52:26 I1X Average and RMS of Measurements VT = -43.567 +- 2.897 uVs I1X = 8.714 +- 0.579 uTm 11:52:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:52:32 Integrated Voltage Measurement... 11:52:41 Voltage Offset Correction: v_off_ini = -383.919 uV, v_off_fin = -392.649 uV 11:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.979 uVs 11:52:41 Integrated Voltage Measurement... 11:52:50 Voltage Offset Correction: v_off_ini = -387.385 uV, v_off_fin = -374.360 uV 11:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.942 uVs 11:52:50 Integrated Voltage Measurement... 11:52:59 Voltage Offset Correction: v_off_ini = -389.100 uV, v_off_fin = -386.464 uV 11:52:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.209 uVs 11:52:59 Integrated Voltage Measurement... 11:53:08 Voltage Offset Correction: v_off_ini = -375.320 uV, v_off_fin = -364.119 uV 11:53:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.006 uVs 11:53:08 Integrated Voltage Measurement... 11:53:17 Voltage Offset Correction: v_off_ini = -358.301 uV, v_off_fin = -394.055 uV 11:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.870 uVs 11:53:17 Integrated Voltage Measurement... 11:53:26 Voltage Offset Correction: v_off_ini = -372.612 uV, v_off_fin = -359.845 uV 11:53:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.286 uVs 11:53:31 I1Y Average and RMS of Measurements VT = -199.215 +- 3.743 uVs I1Y = -39.843 +- 0.749 uTm 11:53:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:38 Integrated Voltage Measurement... 11:53:47 Voltage Offset Correction: v_off_ini = -363.910 uV, v_off_fin = -357.846 uV 11:53:47 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -72.474 uVs 11:53:47 Integrated Voltage Measurement... 11:53:56 Voltage Offset Correction: v_off_ini = -357.658 uV, v_off_fin = -387.355 uV 11:53:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.779 uVs 11:53:56 Integrated Voltage Measurement... 11:54:05 Voltage Offset Correction: v_off_ini = -378.490 uV, v_off_fin = -367.270 uV 11:54:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.768 uVs 11:54:05 Integrated Voltage Measurement... 11:54:14 Voltage Offset Correction: v_off_ini = -373.638 uV, v_off_fin = -372.342 uV 11:54:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.554 uVs 11:54:14 Integrated Voltage Measurement... 11:54:23 Voltage Offset Correction: v_off_ini = -368.199 uV, v_off_fin = -339.840 uV 11:54:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -59.831 uVs 11:54:23 Integrated Voltage Measurement... 11:54:32 Voltage Offset Correction: v_off_ini = -363.916 uV, v_off_fin = -361.805 uV 11:54:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.223 uVs 11:54:35 I2X Average and RMS of Measurements VT = -65.771 +- 7.305 uVs I2X = 6.051 +- 0.672 uTm^2 11:54:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:43 Integrated Voltage Measurement... 11:54:52 Voltage Offset Correction: v_off_ini = -372.219 uV, v_off_fin = -360.464 uV 11:54:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.752 uVs 11:54:52 Integrated Voltage Measurement... 11:55:01 Voltage Offset Correction: v_off_ini = -361.157 uV, v_off_fin = -355.737 uV 11:55:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.560 uVs 11:55:01 Integrated Voltage Measurement... 11:55:10 Voltage Offset Correction: v_off_ini = -355.048 uV, v_off_fin = -375.545 uV 11:55:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.941 uVs 11:55:10 Integrated Voltage Measurement... 11:55:19 Voltage Offset Correction: v_off_ini = -367.338 uV, v_off_fin = -368.437 uV 11:55:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.387 uVs 11:55:19 Integrated Voltage Measurement... 11:55:28 Voltage Offset Correction: v_off_ini = -378.616 uV, v_off_fin = -386.144 uV 11:55:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.715 uVs 11:55:28 Integrated Voltage Measurement... 11:55:37 Voltage Offset Correction: v_off_ini = -382.091 uV, v_off_fin = -374.547 uV 11:55:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.242 uVs 11:55:39 I2Y Average and RMS of Measurements VT = -212.433 +- 10.688 uVs I2Y = -19.544 +- 0.983 uTm^2 11:55:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:55:53 Integrated Voltage Measurement... 11:56:02 Voltage Offset Correction: v_off_ini = -384.671 uV, v_off_fin = -381.645 uV 11:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -15.622 uVs 11:56:02 Integrated Voltage Measurement... 11:56:11 Voltage Offset Correction: v_off_ini = -372.110 uV, v_off_fin = -378.702 uV 11:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.111 uVs 11:56:11 Integrated Voltage Measurement... 11:56:20 Voltage Offset Correction: v_off_ini = -379.819 uV, v_off_fin = -381.771 uV 11:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.841 uVs 11:56:20 Integrated Voltage Measurement... 11:56:29 Voltage Offset Correction: v_off_ini = -372.119 uV, v_off_fin = -368.782 uV 11:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.504 uVs 11:56:29 Integrated Voltage Measurement... 11:56:38 Voltage Offset Correction: v_off_ini = -370.477 uV, v_off_fin = -373.428 uV 11:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.542 uVs 11:56:38 Integrated Voltage Measurement... 11:56:47 Voltage Offset Correction: v_off_ini = -371.559 uV, v_off_fin = -365.402 uV 11:56:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.076 uVs 11:56:51 I1X Average and RMS of Measurements VT = -37.616 +- 13.853 uVs I1X = 7.523 +- 2.771 uTm 11:56:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:58 Integrated Voltage Measurement... 11:57:07 Voltage Offset Correction: v_off_ini = -377.016 uV, v_off_fin = -392.342 uV 11:57:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.122 uVs 11:57:07 Integrated Voltage Measurement... 11:57:16 Voltage Offset Correction: v_off_ini = -391.501 uV, v_off_fin = -383.286 uV 11:57:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.803 uVs 11:57:16 Integrated Voltage Measurement... 11:57:25 Voltage Offset Correction: v_off_ini = -386.152 uV, v_off_fin = -395.752 uV 11:57:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.392 uVs 11:57:25 Integrated Voltage Measurement... 11:57:34 Voltage Offset Correction: v_off_ini = -387.635 uV, v_off_fin = -380.693 uV 11:57:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.492 uVs 11:57:34 Integrated Voltage Measurement... 11:57:43 Voltage Offset Correction: v_off_ini = -390.019 uV, v_off_fin = -405.187 uV 11:57:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.063 uVs 11:57:43 Integrated Voltage Measurement... 11:57:52 Voltage Offset Correction: v_off_ini = -397.619 uV, v_off_fin = -376.786 uV 11:57:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.493 uVs 11:57:56 I1Y Average and RMS of Measurements VT = -198.894 +- 5.316 uVs I1Y = -39.779 +- 1.063 uTm 11:58:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:04 Integrated Voltage Measurement... 11:58:13 Voltage Offset Correction: v_off_ini = -388.072 uV, v_off_fin = -383.504 uV 11:58:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -80.900 uVs 11:58:13 Integrated Voltage Measurement... 11:58:22 Voltage Offset Correction: v_off_ini = -395.807 uV, v_off_fin = -401.138 uV 11:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.961 uVs 11:58:22 Integrated Voltage Measurement... 11:58:31 Voltage Offset Correction: v_off_ini = -390.758 uV, v_off_fin = -386.277 uV 11:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.946 uVs 11:58:31 Integrated Voltage Measurement... 11:58:40 Voltage Offset Correction: v_off_ini = -406.925 uV, v_off_fin = -399.289 uV 11:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.704 uVs 11:58:40 Integrated Voltage Measurement... 11:58:49 Voltage Offset Correction: v_off_ini = -403.261 uV, v_off_fin = -403.109 uV 11:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.992 uVs 11:58:49 Integrated Voltage Measurement... 11:58:58 Voltage Offset Correction: v_off_ini = -391.245 uV, v_off_fin = -402.656 uV 11:58:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.388 uVs 11:59:01 I2X Average and RMS of Measurements VT = -64.815 +- 12.283 uVs I2X = 5.963 +- 1.130 uTm^2 11:59:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:08 Integrated Voltage Measurement... 11:59:17 Voltage Offset Correction: v_off_ini = -385.579 uV, v_off_fin = -394.930 uV 11:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.012 uVs 11:59:17 Integrated Voltage Measurement... 11:59:26 Voltage Offset Correction: v_off_ini = -393.735 uV, v_off_fin = -387.294 uV 11:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.182 uVs 11:59:26 Integrated Voltage Measurement... 11:59:35 Voltage Offset Correction: v_off_ini = -391.056 uV, v_off_fin = -380.281 uV 11:59:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.136 uVs 11:59:35 Integrated Voltage Measurement... 11:59:44 Voltage Offset Correction: v_off_ini = -391.896 uV, v_off_fin = -384.303 uV 11:59:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.140 uVs 11:59:44 Integrated Voltage Measurement... 11:59:53 Voltage Offset Correction: v_off_ini = -385.032 uV, v_off_fin = -377.512 uV 11:59:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.344 uVs 11:59:53 Integrated Voltage Measurement... 12:00:02 Voltage Offset Correction: v_off_ini = -386.215 uV, v_off_fin = -386.160 uV 12:00:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.937 uVs 12:00:05 I2Y Average and RMS of Measurements VT = -218.459 +- 0.481 uVs I2Y = -20.098 +- 0.044 uTm^2 12:00:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:19 Integrated Voltage Measurement... 12:00:28 Voltage Offset Correction: v_off_ini = -406.155 uV, v_off_fin = -398.735 uV 12:00:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.675 uVs 12:00:28 Integrated Voltage Measurement... 12:00:37 Voltage Offset Correction: v_off_ini = -404.886 uV, v_off_fin = -409.689 uV 12:00:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.269 uVs 12:00:37 Integrated Voltage Measurement... 12:00:46 Voltage Offset Correction: v_off_ini = -402.275 uV, v_off_fin = -404.301 uV 12:00:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.888 uVs 12:00:46 Integrated Voltage Measurement... 12:00:55 Voltage Offset Correction: v_off_ini = -398.607 uV, v_off_fin = -392.721 uV 12:00:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.113 uVs 12:00:55 Integrated Voltage Measurement... 12:01:04 Voltage Offset Correction: v_off_ini = -398.540 uV, v_off_fin = -411.771 uV 12:01:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.169 uVs 12:01:04 Integrated Voltage Measurement... 12:01:13 Voltage Offset Correction: v_off_ini = -412.937 uV, v_off_fin = -395.503 uV 12:01:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.031 uVs 12:01:17 I1X Average and RMS of Measurements VT = -48.524 +- 7.082 uVs I1X = 9.705 +- 1.416 uTm 12:01:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:24 Integrated Voltage Measurement... 12:01:33 Voltage Offset Correction: v_off_ini = -390.046 uV, v_off_fin = -398.585 uV 12:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.041 uVs 12:01:33 Integrated Voltage Measurement... 12:01:42 Voltage Offset Correction: v_off_ini = -436.903 uV, v_off_fin = -388.886 uV 12:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.324 uVs 12:01:42 Integrated Voltage Measurement... 12:01:51 Voltage Offset Correction: v_off_ini = -392.519 uV, v_off_fin = -420.053 uV 12:01:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.443 uVs 12:01:51 Integrated Voltage Measurement... 12:02:00 Voltage Offset Correction: v_off_ini = -408.736 uV, v_off_fin = -392.646 uV 12:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.645 uVs 12:02:00 Integrated Voltage Measurement... 12:02:09 Voltage Offset Correction: v_off_ini = -393.790 uV, v_off_fin = -411.825 uV 12:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.896 uVs 12:02:09 Integrated Voltage Measurement... 12:02:18 Voltage Offset Correction: v_off_ini = -407.498 uV, v_off_fin = -402.407 uV 12:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.315 uVs 12:02:22 I1Y Average and RMS of Measurements VT = -192.611 +- 6.648 uVs I1Y = -38.521 +- 1.330 uTm 12:02:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:30 Integrated Voltage Measurement... 12:02:39 Voltage Offset Correction: v_off_ini = -394.960 uV, v_off_fin = -392.102 uV 12:02:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -52.903 uVs 12:02:39 Integrated Voltage Measurement... 12:02:48 Voltage Offset Correction: v_off_ini = -404.881 uV, v_off_fin = -419.837 uV 12:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.525 uVs 12:02:48 Integrated Voltage Measurement... 12:02:57 Voltage Offset Correction: v_off_ini = -414.771 uV, v_off_fin = -392.741 uV 12:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.897 uVs 12:02:57 Integrated Voltage Measurement... 12:03:06 Voltage Offset Correction: v_off_ini = -401.819 uV, v_off_fin = -395.532 uV 12:03:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.909 uVs 12:03:06 Integrated Voltage Measurement... 12:03:15 Voltage Offset Correction: v_off_ini = -400.168 uV, v_off_fin = -394.961 uV 12:03:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.502 uVs 12:03:15 Integrated Voltage Measurement... 12:03:24 Voltage Offset Correction: v_off_ini = -405.131 uV, v_off_fin = -418.413 uV 12:03:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.148 uVs 12:03:26 I2X Average and RMS of Measurements VT = -57.981 +- 4.000 uVs I2X = 5.334 +- 0.368 uTm^2 12:03:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:34 Integrated Voltage Measurement... 12:03:43 Voltage Offset Correction: v_off_ini = -397.661 uV, v_off_fin = -388.476 uV 12:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.282 uVs 12:03:43 Integrated Voltage Measurement... 12:03:52 Voltage Offset Correction: v_off_ini = -407.163 uV, v_off_fin = -395.041 uV 12:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.132 uVs 12:03:52 Integrated Voltage Measurement... 12:04:01 Voltage Offset Correction: v_off_ini = -389.715 uV, v_off_fin = -395.613 uV 12:04:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -219.795 uVs 12:04:01 Integrated Voltage Measurement... 12:04:10 Voltage Offset Correction: v_off_ini = -410.423 uV, v_off_fin = -409.570 uV 12:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.888 uVs 12:04:10 Integrated Voltage Measurement... 12:04:19 Voltage Offset Correction: v_off_ini = -396.341 uV, v_off_fin = -385.844 uV 12:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.307 uVs 12:04:19 Integrated Voltage Measurement... 12:04:28 Voltage Offset Correction: v_off_ini = -414.159 uV, v_off_fin = -386.163 uV 12:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.844 uVs 12:04:31 I2Y Average and RMS of Measurements VT = -220.208 +- 4.075 uVs I2Y = -20.259 +- 0.375 uTm^2 12:04:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:45 Integrated Voltage Measurement... 12:04:53 Voltage Offset Correction: v_off_ini = -390.966 uV, v_off_fin = -385.211 uV 12:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.869 uVs 12:04:54 Integrated Voltage Measurement... 12:05:02 Voltage Offset Correction: v_off_ini = -396.477 uV, v_off_fin = -407.077 uV 12:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.718 uVs 12:05:03 Integrated Voltage Measurement... 12:05:11 Voltage Offset Correction: v_off_ini = -401.608 uV, v_off_fin = -391.913 uV 12:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.798 uVs 12:05:12 Integrated Voltage Measurement... 12:05:20 Voltage Offset Correction: v_off_ini = -395.560 uV, v_off_fin = -392.505 uV 12:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.746 uVs 12:05:21 Integrated Voltage Measurement... 12:05:29 Voltage Offset Correction: v_off_ini = -374.104 uV, v_off_fin = -386.975 uV 12:05:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.791 uVs 12:05:30 Integrated Voltage Measurement... 12:05:38 Voltage Offset Correction: v_off_ini = -381.101 uV, v_off_fin = -388.562 uV 12:05:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.755 uVs 12:05:43 I1X Average and RMS of Measurements VT = -34.446 +- 7.484 uVs I1X = 6.889 +- 1.497 uTm 12:05:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:49 Integrated Voltage Measurement... 12:05:58 Voltage Offset Correction: v_off_ini = -390.635 uV, v_off_fin = -401.652 uV 12:05:58 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -187.045 uVs 12:05:58 Integrated Voltage Measurement... 12:06:07 Voltage Offset Correction: v_off_ini = -400.630 uV, v_off_fin = -385.872 uV 12:06:07 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 213.535 uVs 12:06:07 Integrated Voltage Measurement... 12:06:16 Voltage Offset Correction: v_off_ini = -395.707 uV, v_off_fin = -405.740 uV 12:06:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.101 uVs 12:06:16 Integrated Voltage Measurement... 12:06:25 Voltage Offset Correction: v_off_ini = -385.308 uV, v_off_fin = -386.080 uV 12:06:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.697 uVs 12:06:25 Integrated Voltage Measurement... 12:06:34 Voltage Offset Correction: v_off_ini = -386.924 uV, v_off_fin = -392.391 uV 12:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.931 uVs 12:06:34 Integrated Voltage Measurement... 12:06:43 Voltage Offset Correction: v_off_ini = -386.316 uV, v_off_fin = -372.791 uV 12:06:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.359 uVs 12:06:48 I1Y Average and RMS of Measurements VT = -196.612 +- 2.651 uVs I1Y = -39.319 +- 0.526 uTm 12:06:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:55 Integrated Voltage Measurement... 12:07:04 Voltage Offset Correction: v_off_ini = -380.293 uV, v_off_fin = -392.040 uV 12:07:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -77.428 uVs 12:07:04 Integrated Voltage Measurement... 12:07:13 Voltage Offset Correction: v_off_ini = -391.505 uV, v_off_fin = -402.157 uV 12:07:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.947 uVs 12:07:13 Integrated Voltage Measurement... 12:07:22 Voltage Offset Correction: v_off_ini = -387.739 uV, v_off_fin = -394.253 uV 12:07:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.452 uVs 12:07:22 Integrated Voltage Measurement... 12:07:31 Voltage Offset Correction: v_off_ini = -391.636 uV, v_off_fin = -409.189 uV 12:07:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.622 uVs 12:07:31 Integrated Voltage Measurement... 12:07:40 Voltage Offset Correction: v_off_ini = -396.371 uV, v_off_fin = -382.140 uV 12:07:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.590 uVs 12:07:40 Integrated Voltage Measurement... 12:07:49 Voltage Offset Correction: v_off_ini = -407.536 uV, v_off_fin = -403.707 uV 12:07:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.392 uVs 12:07:52 I2X Average and RMS of Measurements VT = -69.405 +- 11.314 uVs I2X = 6.385 +- 1.041 uTm^2 12:07:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:59 Integrated Voltage Measurement... 12:08:08 Voltage Offset Correction: v_off_ini = -397.715 uV, v_off_fin = -417.063 uV 12:08:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.214 uVs 12:08:09 Integrated Voltage Measurement... 12:08:17 Voltage Offset Correction: v_off_ini = -406.684 uV, v_off_fin = -406.731 uV 12:08:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.015 uVs 12:08:18 Integrated Voltage Measurement... 12:08:26 Voltage Offset Correction: v_off_ini = -418.287 uV, v_off_fin = -403.214 uV 12:08:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.252 uVs 12:08:27 Integrated Voltage Measurement... 12:08:36 Voltage Offset Correction: v_off_ini = -396.534 uV, v_off_fin = -399.647 uV 12:08:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.340 uVs 12:08:36 Integrated Voltage Measurement... 12:08:45 Voltage Offset Correction: v_off_ini = -396.961 uV, v_off_fin = -386.283 uV 12:08:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.117 uVs 12:08:45 Integrated Voltage Measurement... 12:08:54 Voltage Offset Correction: v_off_ini = -387.461 uV, v_off_fin = -381.913 uV 12:08:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.258 uVs 12:08:56 I2Y Average and RMS of Measurements VT = -196.366 +- 17.609 uVs I2Y = -18.066 +- 1.620 uTm^2 12:09:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:10 Integrated Voltage Measurement... 12:09:19 Voltage Offset Correction: v_off_ini = -393.169 uV, v_off_fin = -384.870 uV 12:09:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.743 uVs 12:09:19 Integrated Voltage Measurement... 12:09:28 Voltage Offset Correction: v_off_ini = -377.106 uV, v_off_fin = -363.968 uV 12:09:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.882 uVs 12:09:28 Integrated Voltage Measurement... 12:09:37 Voltage Offset Correction: v_off_ini = -373.515 uV, v_off_fin = -374.479 uV 12:09:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.695 uVs 12:09:37 Integrated Voltage Measurement... 12:09:46 Voltage Offset Correction: v_off_ini = -369.044 uV, v_off_fin = -376.026 uV 12:09:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.716 uVs 12:09:46 Integrated Voltage Measurement... 12:09:55 Voltage Offset Correction: v_off_ini = -377.079 uV, v_off_fin = -372.865 uV 12:09:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.288 uVs 12:09:55 Integrated Voltage Measurement... 12:10:04 Voltage Offset Correction: v_off_ini = -364.525 uV, v_off_fin = -365.602 uV 12:10:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.348 uVs 12:10:08 I1X Average and RMS of Measurements VT = -35.112 +- 0.868 uVs I1X = 7.022 +- 0.174 uTm 12:10:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:15 Integrated Voltage Measurement... 12:10:24 Voltage Offset Correction: v_off_ini = -384.555 uV, v_off_fin = -388.047 uV 12:10:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.084 uVs 12:10:24 Integrated Voltage Measurement... 12:10:33 Voltage Offset Correction: v_off_ini = -378.740 uV, v_off_fin = -361.123 uV 12:10:33 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 207.150 uVs 12:10:33 Integrated Voltage Measurement... 12:10:42 Voltage Offset Correction: v_off_ini = -377.182 uV, v_off_fin = -382.828 uV 12:10:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.253 uVs 12:10:42 Integrated Voltage Measurement... 12:10:51 Voltage Offset Correction: v_off_ini = -377.196 uV, v_off_fin = -353.551 uV 12:10:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.890 uVs 12:10:51 Integrated Voltage Measurement... 12:11:00 Voltage Offset Correction: v_off_ini = -374.597 uV, v_off_fin = -391.716 uV 12:11:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.775 uVs 12:11:00 Integrated Voltage Measurement... 12:11:09 Voltage Offset Correction: v_off_ini = -359.204 uV, v_off_fin = -357.348 uV 12:11:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.968 uVs 12:11:13 I1Y Average and RMS of Measurements VT = -186.353 +- 1.048 uVs I1Y = -37.267 +- 0.207 uTm 12:11:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:21 Integrated Voltage Measurement... 12:11:30 Voltage Offset Correction: v_off_ini = -373.128 uV, v_off_fin = -360.881 uV 12:11:30 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -54.421 uVs 12:11:30 Integrated Voltage Measurement... 12:11:39 Voltage Offset Correction: v_off_ini = -365.017 uV, v_off_fin = -359.728 uV 12:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.371 uVs 12:11:39 Integrated Voltage Measurement... 12:11:48 Voltage Offset Correction: v_off_ini = -363.016 uV, v_off_fin = -368.496 uV 12:11:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.348 uVs 12:11:48 Integrated Voltage Measurement... 12:11:57 Voltage Offset Correction: v_off_ini = -338.809 uV, v_off_fin = -351.160 uV 12:11:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.069 uVs 12:11:57 Integrated Voltage Measurement... 12:12:06 Voltage Offset Correction: v_off_ini = -363.063 uV, v_off_fin = -348.016 uV 12:12:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.110 uVs 12:12:06 Integrated Voltage Measurement... 12:12:15 Voltage Offset Correction: v_off_ini = -348.723 uV, v_off_fin = -368.956 uV 12:12:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.651 uVs 12:12:17 I2X Average and RMS of Measurements VT = -54.162 +- 1.801 uVs I2X = 4.983 +- 0.166 uTm^2 12:12:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:25 Integrated Voltage Measurement... 12:12:34 Voltage Offset Correction: v_off_ini = -358.697 uV, v_off_fin = -354.607 uV 12:12:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.307 uVs 12:12:34 Integrated Voltage Measurement... 12:12:43 Voltage Offset Correction: v_off_ini = -348.196 uV, v_off_fin = -338.202 uV 12:12:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.390 uVs 12:12:43 Integrated Voltage Measurement... 12:12:52 Voltage Offset Correction: v_off_ini = -336.574 uV, v_off_fin = -358.573 uV 12:12:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.849 uVs 12:12:52 Integrated Voltage Measurement... 12:13:01 Voltage Offset Correction: v_off_ini = -352.252 uV, v_off_fin = -351.957 uV 12:13:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.419 uVs 12:13:01 Integrated Voltage Measurement... 12:13:10 Voltage Offset Correction: v_off_ini = -345.191 uV, v_off_fin = -331.792 uV 12:13:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.258 uVs 12:13:10 Integrated Voltage Measurement... 12:13:19 Voltage Offset Correction: v_off_ini = -327.875 uV, v_off_fin = -328.948 uV 12:13:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.079 uVs 12:13:21 I2Y Average and RMS of Measurements VT = -192.550 +- 5.072 uVs I2Y = -17.715 +- 0.467 uTm^2 12:13:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:36 Integrated Voltage Measurement... 12:13:45 Voltage Offset Correction: v_off_ini = -335.009 uV, v_off_fin = -345.519 uV 12:13:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.757 uVs 12:13:45 Integrated Voltage Measurement... 12:13:54 Voltage Offset Correction: v_off_ini = -336.542 uV, v_off_fin = -325.144 uV 12:13:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.626 uVs 12:13:54 Integrated Voltage Measurement... 12:14:03 Voltage Offset Correction: v_off_ini = -309.507 uV, v_off_fin = -321.180 uV 12:14:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.931 uVs 12:14:03 Integrated Voltage Measurement... 12:14:12 Voltage Offset Correction: v_off_ini = -311.243 uV, v_off_fin = -304.929 uV 12:14:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.927 uVs 12:14:12 Integrated Voltage Measurement... 12:14:21 Voltage Offset Correction: v_off_ini = -298.806 uV, v_off_fin = -313.197 uV 12:14:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.552 uVs 12:14:21 Integrated Voltage Measurement... 12:14:30 Voltage Offset Correction: v_off_ini = -320.988 uV, v_off_fin = -295.296 uV 12:14:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.127 uVs 12:14:35 I1X Average and RMS of Measurements VT = -36.654 +- 4.960 uVs I1X = 7.331 +- 0.992 uTm 12:14:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:14:41 Integrated Voltage Measurement... 12:14:50 Voltage Offset Correction: v_off_ini = -318.849 uV, v_off_fin = -328.606 uV 12:14:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.559 uVs 12:14:50 Integrated Voltage Measurement... 12:14:59 Voltage Offset Correction: v_off_ini = -320.347 uV, v_off_fin = -318.743 uV 12:14:59 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 206.792 uVs 12:14:59 Integrated Voltage Measurement... 12:15:08 Voltage Offset Correction: v_off_ini = -321.045 uV, v_off_fin = -325.470 uV 12:15:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.439 uVs 12:15:08 Integrated Voltage Measurement... 12:15:17 Voltage Offset Correction: v_off_ini = -312.018 uV, v_off_fin = -317.529 uV 12:15:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.313 uVs 12:15:17 Integrated Voltage Measurement... 12:15:26 Voltage Offset Correction: v_off_ini = -324.712 uV, v_off_fin = -327.463 uV 12:15:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.206 uVs 12:15:26 Integrated Voltage Measurement... 12:15:35 Voltage Offset Correction: v_off_ini = -323.041 uV, v_off_fin = -319.056 uV 12:15:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.528 uVs 12:15:39 I1Y Average and RMS of Measurements VT = -188.639 +- 5.329 uVs I1Y = -37.725 +- 1.064 uTm 12:15:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:47 Integrated Voltage Measurement... 12:15:56 Voltage Offset Correction: v_off_ini = -321.310 uV, v_off_fin = -327.526 uV 12:15:56 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -32.400 uVs 12:15:56 Integrated Voltage Measurement... 12:16:05 Voltage Offset Correction: v_off_ini = -326.085 uV, v_off_fin = -328.517 uV 12:16:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.889 uVs 12:16:05 Integrated Voltage Measurement... 12:16:14 Voltage Offset Correction: v_off_ini = -315.885 uV, v_off_fin = -316.547 uV 12:16:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.247 uVs 12:16:14 Integrated Voltage Measurement... 12:16:23 Voltage Offset Correction: v_off_ini = -322.754 uV, v_off_fin = -315.285 uV 12:16:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.233 uVs 12:16:23 Integrated Voltage Measurement... 12:16:32 Voltage Offset Correction: v_off_ini = -322.931 uV, v_off_fin = -303.444 uV 12:16:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.435 uVs 12:16:32 Integrated Voltage Measurement... 12:16:41 Voltage Offset Correction: v_off_ini = -325.782 uV, v_off_fin = -329.538 uV 12:16:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.836 uVs 12:16:43 I2X Average and RMS of Measurements VT = -61.507 +- 7.143 uVs I2X = 5.659 +- 0.657 uTm^2 12:16:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:16:51 Integrated Voltage Measurement... 12:17:00 Voltage Offset Correction: v_off_ini = -313.648 uV, v_off_fin = -309.839 uV 12:17:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.544 uVs 12:17:00 Integrated Voltage Measurement... 12:17:09 Voltage Offset Correction: v_off_ini = -309.335 uV, v_off_fin = -312.627 uV 12:17:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.482 uVs 12:17:09 Integrated Voltage Measurement... 12:17:18 Voltage Offset Correction: v_off_ini = -308.833 uV, v_off_fin = -305.260 uV 12:17:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.225 uVs 12:17:18 Integrated Voltage Measurement... 12:17:27 Voltage Offset Correction: v_off_ini = -288.784 uV, v_off_fin = -283.977 uV 12:17:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.573 uVs 12:17:27 Integrated Voltage Measurement... 12:17:36 Voltage Offset Correction: v_off_ini = -280.637 uV, v_off_fin = -289.663 uV 12:17:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.035 uVs 12:17:36 Integrated Voltage Measurement... 12:17:45 Voltage Offset Correction: v_off_ini = -285.818 uV, v_off_fin = -295.092 uV 12:17:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.776 uVs 12:17:48 I2Y Average and RMS of Measurements VT = -207.439 +- 5.878 uVs I2Y = -19.084 +- 0.541 uTm^2 12:17:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:03 Integrated Voltage Measurement... 12:18:12 Voltage Offset Correction: v_off_ini = -295.258 uV, v_off_fin = -285.589 uV 12:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -34.424 uVs 12:18:12 Integrated Voltage Measurement... 12:18:21 Voltage Offset Correction: v_off_ini = -302.266 uV, v_off_fin = -289.125 uV 12:18:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.955 uVs 12:18:21 Integrated Voltage Measurement... 12:18:30 Voltage Offset Correction: v_off_ini = -299.186 uV, v_off_fin = -314.288 uV 12:18:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.542 uVs 12:18:30 Integrated Voltage Measurement... 12:18:39 Voltage Offset Correction: v_off_ini = -303.838 uV, v_off_fin = -287.440 uV 12:18:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.949 uVs 12:18:39 Integrated Voltage Measurement... 12:18:48 Voltage Offset Correction: v_off_ini = -295.706 uV, v_off_fin = -296.857 uV 12:18:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.562 uVs 12:18:48 Integrated Voltage Measurement... 12:18:57 Voltage Offset Correction: v_off_ini = -288.473 uV, v_off_fin = -278.192 uV 12:18:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.284 uVs 12:19:02 I1X Average and RMS of Measurements VT = -33.952 +- 0.998 uVs I1X = 6.791 +- 0.200 uTm 12:19:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:08 Integrated Voltage Measurement... 12:19:17 Voltage Offset Correction: v_off_ini = -269.943 uV, v_off_fin = -296.756 uV 12:19:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.831 uVs 12:19:17 Integrated Voltage Measurement... 12:19:26 Voltage Offset Correction: v_off_ini = -284.196 uV, v_off_fin = -274.532 uV 12:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.065 uVs 12:19:26 Integrated Voltage Measurement... 12:19:35 Voltage Offset Correction: v_off_ini = -274.049 uV, v_off_fin = -288.392 uV 12:19:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.328 uVs 12:19:35 Integrated Voltage Measurement... 12:19:44 Voltage Offset Correction: v_off_ini = -270.464 uV, v_off_fin = -267.830 uV 12:19:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.888 uVs 12:19:44 Integrated Voltage Measurement... 12:19:53 Voltage Offset Correction: v_off_ini = -270.754 uV, v_off_fin = -290.662 uV 12:19:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.508 uVs 12:19:53 Integrated Voltage Measurement... 12:20:02 Voltage Offset Correction: v_off_ini = -287.790 uV, v_off_fin = -271.043 uV 12:20:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.736 uVs 12:20:06 I1Y Average and RMS of Measurements VT = -188.059 +- 6.607 uVs I1Y = -37.612 +- 1.321 uTm 12:20:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:14 Integrated Voltage Measurement... 12:20:23 Voltage Offset Correction: v_off_ini = -260.991 uV, v_off_fin = -276.339 uV 12:20:23 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -76.228 uVs 12:20:23 Integrated Voltage Measurement... 12:20:32 Voltage Offset Correction: v_off_ini = -261.453 uV, v_off_fin = -286.211 uV 12:20:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.262 uVs 12:20:32 Integrated Voltage Measurement... 12:20:41 Voltage Offset Correction: v_off_ini = -292.948 uV, v_off_fin = -269.774 uV 12:20:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.037 uVs 12:20:41 Integrated Voltage Measurement... 12:20:50 Voltage Offset Correction: v_off_ini = -272.254 uV, v_off_fin = -286.226 uV 12:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.724 uVs 12:20:50 Integrated Voltage Measurement... 12:20:59 Voltage Offset Correction: v_off_ini = -280.378 uV, v_off_fin = -266.209 uV 12:20:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.477 uVs 12:20:59 Integrated Voltage Measurement... 12:21:08 Voltage Offset Correction: v_off_ini = -255.864 uV, v_off_fin = -271.068 uV 12:21:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.546 uVs 12:21:11 I2X Average and RMS of Measurements VT = -65.546 +- 1.462 uVs I2X = 6.030 +- 0.134 uTm^2 12:21:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:18 Integrated Voltage Measurement... 12:21:27 Voltage Offset Correction: v_off_ini = -258.731 uV, v_off_fin = -270.448 uV 12:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.390 uVs 12:21:27 Integrated Voltage Measurement... 12:21:36 Voltage Offset Correction: v_off_ini = -277.836 uV, v_off_fin = -273.436 uV 12:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.746 uVs 12:21:36 Integrated Voltage Measurement... 12:21:45 Voltage Offset Correction: v_off_ini = -274.759 uV, v_off_fin = -276.125 uV 12:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.039 uVs 12:21:45 Integrated Voltage Measurement... 12:21:54 Voltage Offset Correction: v_off_ini = -281.310 uV, v_off_fin = -269.142 uV 12:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.959 uVs 12:21:54 Integrated Voltage Measurement... 12:22:03 Voltage Offset Correction: v_off_ini = -284.451 uV, v_off_fin = -278.507 uV 12:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.751 uVs 12:22:03 Integrated Voltage Measurement... 12:22:12 Voltage Offset Correction: v_off_ini = -279.064 uV, v_off_fin = -276.259 uV 12:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.258 uVs 12:22:15 I2Y Average and RMS of Measurements VT = -205.191 +- 6.069 uVs I2Y = -18.878 +- 0.558 uTm^2 12:22:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:32 Integrated Voltage Measurement... 12:22:41 Voltage Offset Correction: v_off_ini = -289.924 uV, v_off_fin = -282.048 uV 12:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.971 uVs 12:22:41 Integrated Voltage Measurement... 12:22:50 Voltage Offset Correction: v_off_ini = -278.953 uV, v_off_fin = -272.074 uV 12:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.215 uVs 12:22:50 Integrated Voltage Measurement... 12:22:59 Voltage Offset Correction: v_off_ini = -261.938 uV, v_off_fin = -265.078 uV 12:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.422 uVs 12:22:59 Integrated Voltage Measurement... 12:23:08 Voltage Offset Correction: v_off_ini = -259.563 uV, v_off_fin = -269.256 uV 12:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.823 uVs 12:23:08 Integrated Voltage Measurement... 12:23:17 Voltage Offset Correction: v_off_ini = -259.095 uV, v_off_fin = -271.204 uV 12:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.293 uVs 12:23:17 Integrated Voltage Measurement... 12:23:26 Voltage Offset Correction: v_off_ini = -282.966 uV, v_off_fin = -260.626 uV 12:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.376 uVs 12:23:30 I1X Average and RMS of Measurements VT = -56.850 +- 9.059 uVs I1X = 11.370 +- 1.812 uTm 12:23:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:23:37 Integrated Voltage Measurement... 12:23:46 Voltage Offset Correction: v_off_ini = -260.772 uV, v_off_fin = -271.007 uV 12:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.496 uVs 12:23:46 Integrated Voltage Measurement... 12:23:55 Voltage Offset Correction: v_off_ini = -261.562 uV, v_off_fin = -253.019 uV 12:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.638 uVs 12:23:55 Integrated Voltage Measurement... 12:24:04 Voltage Offset Correction: v_off_ini = -283.541 uV, v_off_fin = -298.890 uV 12:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.958 uVs 12:24:04 Integrated Voltage Measurement... 12:24:13 Voltage Offset Correction: v_off_ini = -272.517 uV, v_off_fin = -250.920 uV 12:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.735 uVs 12:24:13 Integrated Voltage Measurement... 12:24:22 Voltage Offset Correction: v_off_ini = -273.523 uV, v_off_fin = -272.265 uV 12:24:22 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -199.270 uVs 12:24:22 Integrated Voltage Measurement... 12:24:31 Voltage Offset Correction: v_off_ini = -261.652 uV, v_off_fin = -253.958 uV 12:24:31 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 196.569 uVs 12:24:35 I1Y Average and RMS of Measurements VT = -200.444 +- 2.103 uVs I1Y = -40.086 +- 0.424 uTm 12:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:43 Integrated Voltage Measurement... 12:24:52 Voltage Offset Correction: v_off_ini = -255.823 uV, v_off_fin = -261.748 uV 12:24:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.418 uVs 12:24:52 Integrated Voltage Measurement... 12:25:01 Voltage Offset Correction: v_off_ini = -286.326 uV, v_off_fin = -283.150 uV 12:25:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.168 uVs 12:25:01 Integrated Voltage Measurement... 12:25:10 Voltage Offset Correction: v_off_ini = -278.594 uV, v_off_fin = -253.881 uV 12:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.262 uVs 12:25:10 Integrated Voltage Measurement... 12:25:19 Voltage Offset Correction: v_off_ini = -267.564 uV, v_off_fin = -266.970 uV 12:25:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.927 uVs 12:25:19 Integrated Voltage Measurement... 12:25:28 Voltage Offset Correction: v_off_ini = -261.066 uV, v_off_fin = -247.012 uV 12:25:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.712 uVs 12:25:28 Integrated Voltage Measurement... 12:25:37 Voltage Offset Correction: v_off_ini = -266.603 uV, v_off_fin = -264.333 uV 12:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.758 uVs 12:25:39 I2X Average and RMS of Measurements VT = -74.207 +- 9.023 uVs I2X = 6.827 +- 0.830 uTm^2 12:25:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:47 Integrated Voltage Measurement... 12:25:56 Voltage Offset Correction: v_off_ini = -255.353 uV, v_off_fin = -260.518 uV 12:25:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.127 uVs 12:25:56 Integrated Voltage Measurement... 12:26:05 Voltage Offset Correction: v_off_ini = -258.281 uV, v_off_fin = -267.018 uV 12:26:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.642 uVs 12:26:05 Integrated Voltage Measurement... 12:26:14 Voltage Offset Correction: v_off_ini = -267.130 uV, v_off_fin = -261.737 uV 12:26:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.050 uVs 12:26:14 Integrated Voltage Measurement... 12:26:23 Voltage Offset Correction: v_off_ini = -250.559 uV, v_off_fin = -246.745 uV 12:26:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.839 uVs 12:26:23 Integrated Voltage Measurement... 12:26:32 Voltage Offset Correction: v_off_ini = -265.963 uV, v_off_fin = -268.531 uV 12:26:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.759 uVs 12:26:32 Integrated Voltage Measurement... 12:26:41 Voltage Offset Correction: v_off_ini = -255.565 uV, v_off_fin = -263.218 uV 12:26:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.922 uVs 12:26:44 I2Y Average and RMS of Measurements VT = -214.057 +- 9.204 uVs I2Y = -19.693 +- 0.847 uTm^2 12:26:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:01 Integrated Voltage Measurement... 12:27:10 Voltage Offset Correction: v_off_ini = -272.279 uV, v_off_fin = -266.974 uV 12:27:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.436 uVs 12:27:10 Integrated Voltage Measurement... 12:27:19 Voltage Offset Correction: v_off_ini = -270.288 uV, v_off_fin = -260.140 uV 12:27:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.708 uVs 12:27:19 Integrated Voltage Measurement... 12:27:28 Voltage Offset Correction: v_off_ini = -250.652 uV, v_off_fin = -255.976 uV 12:27:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.223 uVs 12:27:28 Integrated Voltage Measurement... 12:27:37 Voltage Offset Correction: v_off_ini = -258.465 uV, v_off_fin = -267.078 uV 12:27:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.170 uVs 12:27:37 Integrated Voltage Measurement... 12:27:46 Voltage Offset Correction: v_off_ini = -262.581 uV, v_off_fin = -275.639 uV 12:27:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.248 uVs 12:27:46 Integrated Voltage Measurement... 12:27:55 Voltage Offset Correction: v_off_ini = -272.781 uV, v_off_fin = -248.008 uV 12:27:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.093 uVs 12:27:59 I1X Average and RMS of Measurements VT = -61.146 +- 7.824 uVs I1X = 12.229 +- 1.565 uTm 12:28:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:06 Integrated Voltage Measurement... 12:28:15 Voltage Offset Correction: v_off_ini = -262.951 uV, v_off_fin = -270.974 uV 12:28:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.295 uVs 12:28:15 Integrated Voltage Measurement... 12:28:24 Voltage Offset Correction: v_off_ini = -266.807 uV, v_off_fin = -251.997 uV 12:28:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.769 uVs 12:28:24 Integrated Voltage Measurement... 12:28:33 Voltage Offset Correction: v_off_ini = -283.807 uV, v_off_fin = -295.737 uV 12:28:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.217 uVs 12:28:33 Integrated Voltage Measurement... 12:28:42 Voltage Offset Correction: v_off_ini = -295.115 uV, v_off_fin = -281.221 uV 12:28:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.338 uVs 12:28:42 Integrated Voltage Measurement... 12:28:51 Voltage Offset Correction: v_off_ini = -287.144 uV, v_off_fin = -284.449 uV 12:28:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.055 uVs 12:28:51 Integrated Voltage Measurement... 12:29:00 Voltage Offset Correction: v_off_ini = -276.878 uV, v_off_fin = -259.644 uV 12:29:00 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 224.001 uVs 12:29:04 I1Y Average and RMS of Measurements VT = -209.613 +- 6.488 uVs I1Y = -41.920 +- 1.296 uTm 12:29:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:12 Integrated Voltage Measurement... 12:29:21 Voltage Offset Correction: v_off_ini = -255.555 uV, v_off_fin = -255.192 uV 12:29:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.275 uVs 12:29:21 Integrated Voltage Measurement... 12:29:30 Voltage Offset Correction: v_off_ini = -267.340 uV, v_off_fin = -270.628 uV 12:29:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.649 uVs 12:29:30 Integrated Voltage Measurement... 12:29:39 Voltage Offset Correction: v_off_ini = -255.578 uV, v_off_fin = -261.135 uV 12:29:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.907 uVs 12:29:39 Integrated Voltage Measurement... 12:29:48 Voltage Offset Correction: v_off_ini = -264.240 uV, v_off_fin = -271.708 uV 12:29:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.955 uVs 12:29:48 Integrated Voltage Measurement... 12:29:57 Voltage Offset Correction: v_off_ini = -258.909 uV, v_off_fin = -253.331 uV 12:29:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.214 uVs 12:29:57 Integrated Voltage Measurement... 12:30:06 Voltage Offset Correction: v_off_ini = -290.558 uV, v_off_fin = -278.829 uV 12:30:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.813 uVs 12:30:08 I2X Average and RMS of Measurements VT = -84.135 +- 1.687 uVs I2X = 7.740 +- 0.155 uTm^2 12:30:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:16 Integrated Voltage Measurement... 12:30:25 Voltage Offset Correction: v_off_ini = -249.095 uV, v_off_fin = -274.851 uV 12:30:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.013 uVs 12:30:25 Integrated Voltage Measurement... 12:30:34 Voltage Offset Correction: v_off_ini = -273.081 uV, v_off_fin = -272.417 uV 12:30:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.068 uVs 12:30:34 Integrated Voltage Measurement... 12:30:43 Voltage Offset Correction: v_off_ini = -283.791 uV, v_off_fin = -269.976 uV 12:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.541 uVs 12:30:43 Integrated Voltage Measurement... 12:30:52 Voltage Offset Correction: v_off_ini = -266.407 uV, v_off_fin = -266.759 uV 12:30:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.715 uVs 12:30:52 Integrated Voltage Measurement... 12:31:01 Voltage Offset Correction: v_off_ini = -274.112 uV, v_off_fin = -275.858 uV 12:31:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.784 uVs 12:31:01 Integrated Voltage Measurement... 12:31:10 Voltage Offset Correction: v_off_ini = -276.387 uV, v_off_fin = -274.844 uV 12:31:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.667 uVs 12:31:12 I2Y Average and RMS of Measurements VT = -219.632 +- 9.286 uVs I2Y = -20.206 +- 0.854 uTm^2 12:31:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:30 Integrated Voltage Measurement... 12:31:39 Voltage Offset Correction: v_off_ini = -268.984 uV, v_off_fin = -268.110 uV 12:31:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.654 uVs 12:31:39 Integrated Voltage Measurement... 12:31:48 Voltage Offset Correction: v_off_ini = -272.441 uV, v_off_fin = -267.036 uV 12:31:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.684 uVs 12:31:48 Integrated Voltage Measurement... 12:31:57 Voltage Offset Correction: v_off_ini = -274.752 uV, v_off_fin = -281.507 uV 12:31:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.890 uVs 12:31:57 Integrated Voltage Measurement... 12:32:06 Voltage Offset Correction: v_off_ini = -288.960 uV, v_off_fin = -274.453 uV 12:32:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.551 uVs 12:32:06 Integrated Voltage Measurement... 12:32:15 Voltage Offset Correction: v_off_ini = -264.403 uV, v_off_fin = -258.148 uV 12:32:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.235 uVs 12:32:15 Integrated Voltage Measurement... 12:32:24 Voltage Offset Correction: v_off_ini = -269.849 uV, v_off_fin = -267.795 uV 12:32:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.673 uVs 12:32:28 I1X Average and RMS of Measurements VT = -56.448 +- 11.452 uVs I1X = 11.290 +- 2.290 uTm 12:32:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:32:35 Integrated Voltage Measurement... 12:32:44 Voltage Offset Correction: v_off_ini = -276.226 uV, v_off_fin = -281.644 uV 12:32:44 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.279 uVs 12:32:44 Integrated Voltage Measurement... 12:32:53 Voltage Offset Correction: v_off_ini = -264.104 uV, v_off_fin = -259.669 uV 12:32:53 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 233.120 uVs 12:32:53 Integrated Voltage Measurement... 12:33:02 Voltage Offset Correction: v_off_ini = -268.929 uV, v_off_fin = -277.039 uV 12:33:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.675 uVs 12:33:02 Integrated Voltage Measurement... 12:33:11 Voltage Offset Correction: v_off_ini = -263.160 uV, v_off_fin = -238.767 uV 12:33:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.095 uVs 12:33:11 Integrated Voltage Measurement... 12:33:20 Voltage Offset Correction: v_off_ini = -261.421 uV, v_off_fin = -259.241 uV 12:33:20 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -240.022 uVs 12:33:20 Integrated Voltage Measurement... 12:33:29 Voltage Offset Correction: v_off_ini = -256.206 uV, v_off_fin = -243.986 uV 12:33:29 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 226.732 uVs 12:33:33 I1Y Average and RMS of Measurements VT = -226.487 +- 8.252 uVs I1Y = -45.291 +- 1.647 uTm 12:33:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:33:41 Integrated Voltage Measurement... 12:33:50 Voltage Offset Correction: v_off_ini = -259.181 uV, v_off_fin = -256.824 uV 12:33:50 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -105.748 uVs 12:33:50 Integrated Voltage Measurement... 12:33:59 Voltage Offset Correction: v_off_ini = -263.123 uV, v_off_fin = -257.678 uV 12:33:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.783 uVs 12:33:59 Integrated Voltage Measurement... 12:34:08 Voltage Offset Correction: v_off_ini = -249.065 uV, v_off_fin = -243.595 uV 12:34:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.359 uVs 12:34:08 Integrated Voltage Measurement... 12:34:17 Voltage Offset Correction: v_off_ini = -243.950 uV, v_off_fin = -255.454 uV 12:34:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.118 uVs 12:34:17 Integrated Voltage Measurement... 12:34:26 Voltage Offset Correction: v_off_ini = -253.180 uV, v_off_fin = -236.194 uV 12:34:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -71.637 uVs 12:34:26 Integrated Voltage Measurement... 12:34:35 Voltage Offset Correction: v_off_ini = -244.146 uV, v_off_fin = -248.875 uV 12:34:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.190 uVs 12:34:37 I2X Average and RMS of Measurements VT = -88.639 +- 2.641 uVs I2X = 8.155 +- 0.242 uTm^2 12:34:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:45 Integrated Voltage Measurement... 12:34:54 Voltage Offset Correction: v_off_ini = -236.721 uV, v_off_fin = -248.133 uV 12:34:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.762 uVs 12:34:54 Integrated Voltage Measurement... 12:35:03 Voltage Offset Correction: v_off_ini = -241.588 uV, v_off_fin = -238.772 uV 12:35:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.967 uVs 12:35:03 Integrated Voltage Measurement... 12:35:12 Voltage Offset Correction: v_off_ini = -233.219 uV, v_off_fin = -232.139 uV 12:35:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.585 uVs 12:35:12 Integrated Voltage Measurement... 12:35:21 Voltage Offset Correction: v_off_ini = -246.312 uV, v_off_fin = -237.773 uV 12:35:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.272 uVs 12:35:21 Integrated Voltage Measurement... 12:35:30 Voltage Offset Correction: v_off_ini = -232.559 uV, v_off_fin = -235.749 uV 12:35:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.112 uVs 12:35:30 Integrated Voltage Measurement... 12:35:39 Voltage Offset Correction: v_off_ini = -242.439 uV, v_off_fin = -238.612 uV 12:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.634 uVs 12:35:42 I2Y Average and RMS of Measurements VT = -235.389 +- 8.038 uVs I2Y = -21.656 +- 0.740 uTm^2 12:35:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:59 Integrated Voltage Measurement... 12:36:08 Voltage Offset Correction: v_off_ini = -224.650 uV, v_off_fin = -246.836 uV 12:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.424 uVs 12:36:08 Integrated Voltage Measurement... 12:36:17 Voltage Offset Correction: v_off_ini = -230.287 uV, v_off_fin = -227.930 uV 12:36:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.582 uVs 12:36:17 Integrated Voltage Measurement... 12:36:26 Voltage Offset Correction: v_off_ini = -230.101 uV, v_off_fin = -227.842 uV 12:36:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.901 uVs 12:36:26 Integrated Voltage Measurement... 12:36:35 Voltage Offset Correction: v_off_ini = -230.796 uV, v_off_fin = -232.982 uV 12:36:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.724 uVs 12:36:35 Integrated Voltage Measurement... 12:36:44 Voltage Offset Correction: v_off_ini = -232.836 uV, v_off_fin = -226.014 uV 12:36:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.991 uVs 12:36:44 Integrated Voltage Measurement... 12:36:53 Voltage Offset Correction: v_off_ini = -225.962 uV, v_off_fin = -233.566 uV 12:36:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.084 uVs 12:36:57 I1X Average and RMS of Measurements VT = -67.284 +- 0.721 uVs I1X = 13.457 +- 0.144 uTm 12:37:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:37:04 Integrated Voltage Measurement... 12:37:13 Voltage Offset Correction: v_off_ini = -229.106 uV, v_off_fin = -229.562 uV 12:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -243.457 uVs 12:37:13 Integrated Voltage Measurement... 12:37:22 Voltage Offset Correction: v_off_ini = -224.116 uV, v_off_fin = -208.070 uV 12:37:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.258 uVs 12:37:22 Integrated Voltage Measurement... 12:37:31 Voltage Offset Correction: v_off_ini = -210.916 uV, v_off_fin = -238.284 uV 12:37:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.559 uVs 12:37:31 Integrated Voltage Measurement... 12:37:40 Voltage Offset Correction: v_off_ini = -215.523 uV, v_off_fin = -212.006 uV 12:37:40 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 250.753 uVs 12:37:40 Integrated Voltage Measurement... 12:37:49 Voltage Offset Correction: v_off_ini = -216.359 uV, v_off_fin = -231.135 uV 12:37:49 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -239.623 uVs 12:37:49 Integrated Voltage Measurement... 12:37:58 Voltage Offset Correction: v_off_ini = -234.016 uV, v_off_fin = -211.513 uV 12:37:58 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 266.050 uVs 12:38:02 I1Y Average and RMS of Measurements VT = -245.783 +- 5.011 uVs I1Y = -49.150 +- 1.000 uTm 12:38:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:10 Integrated Voltage Measurement... 12:38:19 Voltage Offset Correction: v_off_ini = -214.810 uV, v_off_fin = -222.875 uV 12:38:19 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -103.707 uVs 12:38:19 Integrated Voltage Measurement... 12:38:28 Voltage Offset Correction: v_off_ini = -213.339 uV, v_off_fin = -217.929 uV 12:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.294 uVs 12:38:28 Integrated Voltage Measurement... 12:38:37 Voltage Offset Correction: v_off_ini = -206.577 uV, v_off_fin = -205.843 uV 12:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.235 uVs 12:38:37 Integrated Voltage Measurement... 12:38:46 Voltage Offset Correction: v_off_ini = -225.324 uV, v_off_fin = -229.660 uV 12:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.696 uVs 12:38:46 Integrated Voltage Measurement... 12:38:55 Voltage Offset Correction: v_off_ini = -223.079 uV, v_off_fin = -208.119 uV 12:38:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.191 uVs 12:38:55 Integrated Voltage Measurement... 12:39:04 Voltage Offset Correction: v_off_ini = -212.927 uV, v_off_fin = -226.418 uV 12:39:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.652 uVs 12:39:07 I2X Average and RMS of Measurements VT = -85.296 +- 9.221 uVs I2X = 7.847 +- 0.848 uTm^2 12:39:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:14 Integrated Voltage Measurement... 12:39:23 Voltage Offset Correction: v_off_ini = -197.168 uV, v_off_fin = -200.799 uV 12:39:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.114 uVs 12:39:23 Integrated Voltage Measurement... 12:39:32 Voltage Offset Correction: v_off_ini = -199.909 uV, v_off_fin = -184.788 uV 12:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.046 uVs 12:39:32 Integrated Voltage Measurement... 12:39:41 Voltage Offset Correction: v_off_ini = -204.963 uV, v_off_fin = -203.885 uV 12:39:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.858 uVs 12:39:41 Integrated Voltage Measurement... 12:39:50 Voltage Offset Correction: v_off_ini = -206.311 uV, v_off_fin = -206.828 uV 12:39:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.113 uVs 12:39:50 Integrated Voltage Measurement... 12:39:59 Voltage Offset Correction: v_off_ini = -215.106 uV, v_off_fin = -214.968 uV 12:39:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.879 uVs 12:39:59 Integrated Voltage Measurement... 12:40:08 Voltage Offset Correction: v_off_ini = -211.607 uV, v_off_fin = -203.788 uV 12:40:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.549 uVs 12:40:11 I2Y Average and RMS of Measurements VT = -247.593 +- 9.408 uVs I2Y = -22.779 +- 0.866 uTm^2 12:40:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:40:28 Integrated Voltage Measurement... 12:40:37 Voltage Offset Correction: v_off_ini = -207.339 uV, v_off_fin = -211.567 uV 12:40:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.950 uVs 12:40:37 Integrated Voltage Measurement... 12:40:46 Voltage Offset Correction: v_off_ini = -203.662 uV, v_off_fin = -200.391 uV 12:40:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.898 uVs 12:40:46 Integrated Voltage Measurement... 12:40:55 Voltage Offset Correction: v_off_ini = -196.929 uV, v_off_fin = -207.586 uV 12:40:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.944 uVs 12:40:55 Integrated Voltage Measurement... 12:41:04 Voltage Offset Correction: v_off_ini = -194.789 uV, v_off_fin = -201.027 uV 12:41:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.981 uVs 12:41:04 Integrated Voltage Measurement... 12:41:13 Voltage Offset Correction: v_off_ini = -207.648 uV, v_off_fin = -213.351 uV 12:41:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.546 uVs 12:41:13 Integrated Voltage Measurement... 12:41:22 Voltage Offset Correction: v_off_ini = -215.372 uV, v_off_fin = -221.085 uV 12:41:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.812 uVs 12:41:27 I1X Average and RMS of Measurements VT = -65.522 +- 8.116 uVs I1X = 13.105 +- 1.624 uTm 12:41:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:33 Integrated Voltage Measurement... 12:41:42 Voltage Offset Correction: v_off_ini = -208.740 uV, v_off_fin = -234.367 uV 12:41:42 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.096 uVs 12:41:42 Integrated Voltage Measurement... 12:41:51 Voltage Offset Correction: v_off_ini = -230.980 uV, v_off_fin = -226.156 uV 12:41:51 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 253.994 uVs 12:41:51 Integrated Voltage Measurement... 12:42:00 Voltage Offset Correction: v_off_ini = -215.356 uV, v_off_fin = -236.418 uV 12:42:00 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -241.346 uVs 12:42:00 Integrated Voltage Measurement... 12:42:09 Voltage Offset Correction: v_off_ini = -232.260 uV, v_off_fin = -208.302 uV 12:42:09 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 259.689 uVs 12:42:09 Integrated Voltage Measurement... 12:42:18 Voltage Offset Correction: v_off_ini = -216.536 uV, v_off_fin = -237.856 uV 12:42:18 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -238.870 uVs 12:42:18 Integrated Voltage Measurement... 12:42:27 Voltage Offset Correction: v_off_ini = -217.966 uV, v_off_fin = -208.270 uV 12:42:27 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 257.028 uVs 12:42:32 I1Y Average and RMS of Measurements VT = -247.171 +- 3.100 uVs I1Y = -49.424 +- 0.619 uTm 12:42:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:39 Integrated Voltage Measurement... 12:42:48 Voltage Offset Correction: v_off_ini = -219.701 uV, v_off_fin = -215.642 uV 12:42:48 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -105.657 uVs 12:42:48 Integrated Voltage Measurement... 12:42:57 Voltage Offset Correction: v_off_ini = -221.983 uV, v_off_fin = -231.456 uV 12:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.210 uVs 12:42:57 Integrated Voltage Measurement... 12:43:06 Voltage Offset Correction: v_off_ini = -222.271 uV, v_off_fin = -204.899 uV 12:43:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.971 uVs 12:43:06 Integrated Voltage Measurement... 12:43:15 Voltage Offset Correction: v_off_ini = -212.226 uV, v_off_fin = -232.304 uV 12:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.119 uVs 12:43:15 Integrated Voltage Measurement... 12:43:24 Voltage Offset Correction: v_off_ini = -223.793 uV, v_off_fin = -231.731 uV 12:43:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.770 uVs 12:43:24 Integrated Voltage Measurement... 12:43:33 Voltage Offset Correction: v_off_ini = -239.536 uV, v_off_fin = -248.745 uV 12:43:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.769 uVs 12:43:36 I2X Average and RMS of Measurements VT = -100.749 +- 11.436 uVs I2X = 9.269 +- 1.052 uTm^2 12:43:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:44 Integrated Voltage Measurement... 12:43:53 Voltage Offset Correction: v_off_ini = -226.497 uV, v_off_fin = -240.412 uV 12:43:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.197 uVs 12:43:53 Integrated Voltage Measurement... 12:44:02 Voltage Offset Correction: v_off_ini = -256.375 uV, v_off_fin = -229.259 uV 12:44:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.051 uVs 12:44:02 Integrated Voltage Measurement... 12:44:11 Voltage Offset Correction: v_off_ini = -246.028 uV, v_off_fin = -239.541 uV 12:44:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.005 uVs 12:44:11 Integrated Voltage Measurement... 12:44:20 Voltage Offset Correction: v_off_ini = -226.951 uV, v_off_fin = -230.367 uV 12:44:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.590 uVs 12:44:20 Integrated Voltage Measurement... 12:44:29 Voltage Offset Correction: v_off_ini = -226.199 uV, v_off_fin = -226.258 uV 12:44:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.818 uVs 12:44:29 Integrated Voltage Measurement... 12:44:38 Voltage Offset Correction: v_off_ini = -220.345 uV, v_off_fin = -220.989 uV 12:44:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.091 uVs 12:44:40 I2Y Average and RMS of Measurements VT = -260.958 +- 2.946 uVs I2Y = -24.008 +- 0.271 uTm^2 12:44:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:55 Integrated Voltage Measurement... 12:45:04 Voltage Offset Correction: v_off_ini = -249.052 uV, v_off_fin = -238.120 uV 12:45:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.700 uVs 12:45:04 Integrated Voltage Measurement... 12:45:13 Voltage Offset Correction: v_off_ini = -223.358 uV, v_off_fin = -225.568 uV 12:45:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.715 uVs 12:45:13 Integrated Voltage Measurement... 12:45:22 Voltage Offset Correction: v_off_ini = -223.632 uV, v_off_fin = -248.406 uV 12:45:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.163 uVs 12:45:22 Integrated Voltage Measurement... 12:45:31 Voltage Offset Correction: v_off_ini = -223.144 uV, v_off_fin = -240.036 uV 12:45:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.348 uVs 12:45:31 Integrated Voltage Measurement... 12:45:40 Voltage Offset Correction: v_off_ini = -234.054 uV, v_off_fin = -241.911 uV 12:45:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.874 uVs 12:45:40 Integrated Voltage Measurement... 12:45:49 Voltage Offset Correction: v_off_ini = -238.842 uV, v_off_fin = -243.350 uV 12:45:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.219 uVs 12:45:54 I1X Average and RMS of Measurements VT = -64.503 +- 7.081 uVs I1X = 12.901 +- 1.416 uTm 12:45:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:00 Integrated Voltage Measurement... 12:46:09 Voltage Offset Correction: v_off_ini = -248.270 uV, v_off_fin = -257.778 uV 12:46:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.193 uVs 12:46:09 Integrated Voltage Measurement... 12:46:18 Voltage Offset Correction: v_off_ini = -244.866 uV, v_off_fin = -224.758 uV 12:46:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.365 uVs 12:46:18 Integrated Voltage Measurement... 12:46:27 Voltage Offset Correction: v_off_ini = -241.194 uV, v_off_fin = -257.049 uV 12:46:27 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -245.452 uVs 12:46:27 Integrated Voltage Measurement... 12:46:36 Voltage Offset Correction: v_off_ini = -235.602 uV, v_off_fin = -219.392 uV 12:46:36 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 253.084 uVs 12:46:36 Integrated Voltage Measurement... 12:46:45 Voltage Offset Correction: v_off_ini = -239.965 uV, v_off_fin = -251.516 uV 12:46:45 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -256.205 uVs 12:46:45 Integrated Voltage Measurement... 12:46:54 Voltage Offset Correction: v_off_ini = -234.445 uV, v_off_fin = -222.394 uV 12:46:54 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 264.729 uVs 12:46:59 I1Y Average and RMS of Measurements VT = -254.838 +- 4.572 uVs I1Y = -50.959 +- 0.914 uTm 12:47:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:06 Integrated Voltage Measurement... 12:47:15 Voltage Offset Correction: v_off_ini = -228.149 uV, v_off_fin = -218.455 uV 12:47:15 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -101.819 uVs 12:47:15 Integrated Voltage Measurement... 12:47:24 Voltage Offset Correction: v_off_ini = -246.129 uV, v_off_fin = -243.453 uV 12:47:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.110 uVs 12:47:24 Integrated Voltage Measurement... 12:47:33 Voltage Offset Correction: v_off_ini = -243.585 uV, v_off_fin = -248.278 uV 12:47:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.302 uVs 12:47:33 Integrated Voltage Measurement... 12:47:42 Voltage Offset Correction: v_off_ini = -246.561 uV, v_off_fin = -258.844 uV 12:47:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.287 uVs 12:47:42 Integrated Voltage Measurement... 12:47:51 Voltage Offset Correction: v_off_ini = -229.529 uV, v_off_fin = -247.350 uV 12:47:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.313 uVs 12:47:51 Integrated Voltage Measurement... 12:48:00 Voltage Offset Correction: v_off_ini = -252.274 uV, v_off_fin = -253.819 uV 12:48:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.172 uVs 12:48:03 I2X Average and RMS of Measurements VT = -94.834 +- 4.755 uVs I2X = 8.725 +- 0.437 uTm^2 12:48:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:11 Integrated Voltage Measurement... 12:48:20 Voltage Offset Correction: v_off_ini = -237.303 uV, v_off_fin = -242.477 uV 12:48:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.455 uVs 12:48:20 Integrated Voltage Measurement... 12:48:29 Voltage Offset Correction: v_off_ini = -235.765 uV, v_off_fin = -235.776 uV 12:48:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.342 uVs 12:48:29 Integrated Voltage Measurement... 12:48:38 Voltage Offset Correction: v_off_ini = -233.006 uV, v_off_fin = -233.726 uV 12:48:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.552 uVs 12:48:38 Integrated Voltage Measurement... 12:48:47 Voltage Offset Correction: v_off_ini = -268.670 uV, v_off_fin = -247.923 uV 12:48:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.318 uVs 12:48:47 Integrated Voltage Measurement... 12:48:56 Voltage Offset Correction: v_off_ini = -251.373 uV, v_off_fin = -228.304 uV 12:48:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.517 uVs 12:48:56 Integrated Voltage Measurement... 12:49:05 Voltage Offset Correction: v_off_ini = -227.257 uV, v_off_fin = -226.669 uV 12:49:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.073 uVs 12:49:07 I2Y Average and RMS of Measurements VT = -267.709 +- 10.476 uVs I2Y = -24.629 +- 0.964 uTm^2 12:49:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm