SLAC Magnetic Measurements Date: 04-22-2025 Time: 11:21:18 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE-SXPS_16348 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 3 Measurement Device: Operator: YL Comment: Tuning 11:21:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:28 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:21:30 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:21:31 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:21:33 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:21:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:46 Integrated Voltage Measurement... 11:21:55 Voltage Offset Correction: v_off_ini = -401.177 uV, v_off_fin = -421.363 uV 11:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.396 uVs 11:21:55 Integrated Voltage Measurement... 11:22:04 Voltage Offset Correction: v_off_ini = -389.841 uV, v_off_fin = -390.618 uV 11:22:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.691 uVs 11:22:04 Integrated Voltage Measurement... 11:22:13 Voltage Offset Correction: v_off_ini = -388.219 uV, v_off_fin = -401.448 uV 11:22:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.714 uVs 11:22:13 Integrated Voltage Measurement... 11:22:22 Voltage Offset Correction: v_off_ini = -400.614 uV, v_off_fin = -404.887 uV 11:22:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.417 uVs 11:22:22 Integrated Voltage Measurement... 11:22:31 Voltage Offset Correction: v_off_ini = -407.497 uV, v_off_fin = -400.743 uV 11:22:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.201 uVs 11:22:31 Integrated Voltage Measurement... 11:22:40 Voltage Offset Correction: v_off_ini = -380.925 uV, v_off_fin = -379.790 uV 11:22:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.816 uVs 11:22:44 I1X Average and RMS of Measurements VT = -60.372 +- 5.482 uVs I1X = 12.074 +- 1.096 uTm 11:22:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:51 Integrated Voltage Measurement... 11:23:00 Voltage Offset Correction: v_off_ini = -397.956 uV, v_off_fin = -384.094 uV 11:23:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.708 uVs 11:23:00 Integrated Voltage Measurement... 11:23:09 Voltage Offset Correction: v_off_ini = -379.144 uV, v_off_fin = -375.049 uV 11:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.824 uVs 11:23:09 Integrated Voltage Measurement... 11:23:18 Voltage Offset Correction: v_off_ini = -375.277 uV, v_off_fin = -397.168 uV 11:23:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.279 uVs 11:23:18 Integrated Voltage Measurement... 11:23:27 Voltage Offset Correction: v_off_ini = -394.934 uV, v_off_fin = -385.653 uV 11:23:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.539 uVs 11:23:27 Integrated Voltage Measurement... 11:23:36 Voltage Offset Correction: v_off_ini = -376.801 uV, v_off_fin = -410.722 uV 11:23:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.690 uVs 11:23:36 Integrated Voltage Measurement... 11:23:45 Voltage Offset Correction: v_off_ini = -390.833 uV, v_off_fin = -374.874 uV 11:23:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.504 uVs 11:23:49 I1Y Average and RMS of Measurements VT = -237.091 +- 3.842 uVs I1Y = -47.418 +- 0.768 uTm