SLAC Magnetic Measurements Date: 10-21-2025 Time: 10:09:42 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16347 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 3 Measurement Device: Stretched Wire Operator: YL Comment: 10:09:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:09:52 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:09:54 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:09:55 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:09:57 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 10:10:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:10:12 Integrated Voltage Measurement... 10:10:21 Voltage Offset Correction: v_off_ini = -334.415 uV, v_off_fin = -328.031 uV 10:10:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.498 uVs 10:10:22 Integrated Voltage Measurement... 10:10:31 Voltage Offset Correction: v_off_ini = -307.138 uV, v_off_fin = -313.369 uV 10:10:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.822 uVs 10:10:31 Integrated Voltage Measurement... 10:10:40 Voltage Offset Correction: v_off_ini = -317.956 uV, v_off_fin = -307.647 uV 10:10:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.126 uVs 10:10:40 Integrated Voltage Measurement... 10:10:49 Voltage Offset Correction: v_off_ini = -317.188 uV, v_off_fin = -300.614 uV 10:10:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.675 uVs 10:10:49 Integrated Voltage Measurement... 10:10:58 Voltage Offset Correction: v_off_ini = -298.681 uV, v_off_fin = -294.339 uV 10:10:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.999 uVs 10:10:58 Integrated Voltage Measurement... 10:11:07 Voltage Offset Correction: v_off_ini = -285.662 uV, v_off_fin = -283.862 uV 10:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.771 uVs 10:11:11 I1X Average and RMS of Measurements VT = -128.648 +- 2.199 uVs I1X = 25.730 +- 0.440 uTm 10:11:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:11:18 Integrated Voltage Measurement... 10:11:27 Voltage Offset Correction: v_off_ini = -290.827 uV, v_off_fin = -312.311 uV 10:11:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.233 uVs 10:11:27 Integrated Voltage Measurement... 10:11:36 Voltage Offset Correction: v_off_ini = -293.032 uV, v_off_fin = -291.951 uV 10:11:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 138.213 uVs 10:11:36 Integrated Voltage Measurement... 10:11:45 Voltage Offset Correction: v_off_ini = -295.558 uV, v_off_fin = -302.919 uV 10:11:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -127.432 uVs 10:11:45 Integrated Voltage Measurement... 10:11:54 Voltage Offset Correction: v_off_ini = -297.949 uV, v_off_fin = -279.240 uV 10:11:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 147.624 uVs 10:11:54 Integrated Voltage Measurement... 10:12:03 Voltage Offset Correction: v_off_ini = -280.763 uV, v_off_fin = -294.947 uV 10:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.182 uVs 10:12:03 Integrated Voltage Measurement... 10:12:12 Voltage Offset Correction: v_off_ini = -264.009 uV, v_off_fin = -249.809 uV 10:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 128.708 uVs 10:12:16 I1Y Average and RMS of Measurements VT = -133.065 +- 3.512 uVs I1Y = -26.611 +- 0.702 uTm 10:12:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:12:23 Integrated Voltage Measurement... 10:12:32 Voltage Offset Correction: v_off_ini = -246.343 uV, v_off_fin = -258.688 uV 10:12:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.923 uVs 10:12:33 Integrated Voltage Measurement... 10:12:42 Voltage Offset Correction: v_off_ini = -247.371 uV, v_off_fin = -237.026 uV 10:12:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.101 uVs 10:12:42 Integrated Voltage Measurement... 10:12:51 Voltage Offset Correction: v_off_ini = -243.211 uV, v_off_fin = -248.785 uV 10:12:51 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -133.268 uVs 10:12:51 Integrated Voltage Measurement... 10:13:00 Voltage Offset Correction: v_off_ini = -242.755 uV, v_off_fin = -225.011 uV 10:13:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.145 uVs 10:13:00 Integrated Voltage Measurement... 10:13:09 Voltage Offset Correction: v_off_ini = -236.689 uV, v_off_fin = -251.893 uV 10:13:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -153.052 uVs 10:13:09 Integrated Voltage Measurement... 10:13:18 Voltage Offset Correction: v_off_ini = -240.060 uV, v_off_fin = -206.480 uV 10:13:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 140.396 uVs 10:13:20 I2X Average and RMS of Measurements VT = -142.314 +- 3.684 uVs I2X = 13.094 +- 0.339 uTm^2 10:13:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:13:28 Integrated Voltage Measurement... 10:13:37 Voltage Offset Correction: v_off_ini = -228.215 uV, v_off_fin = -210.987 uV 10:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.997 uVs 10:13:37 Integrated Voltage Measurement... 10:13:46 Voltage Offset Correction: v_off_ini = -218.108 uV, v_off_fin = -227.059 uV 10:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.932 uVs 10:13:46 Integrated Voltage Measurement... 10:13:55 Voltage Offset Correction: v_off_ini = -214.847 uV, v_off_fin = -230.857 uV 10:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.087 uVs 10:13:55 Integrated Voltage Measurement... 10:14:04 Voltage Offset Correction: v_off_ini = -223.459 uV, v_off_fin = -220.582 uV 10:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.406 uVs 10:14:04 Integrated Voltage Measurement... 10:14:13 Voltage Offset Correction: v_off_ini = -218.709 uV, v_off_fin = -214.920 uV 10:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.904 uVs 10:14:13 Integrated Voltage Measurement... 10:14:22 Voltage Offset Correction: v_off_ini = -204.264 uV, v_off_fin = -201.860 uV 10:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.442 uVs 10:14:25 I2Y Average and RMS of Measurements VT = -176.128 +- 6.827 uVs I2Y = -16.204 +- 0.628 uTm^2 10:14:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:14:40 Integrated Voltage Measurement... 10:14:48 Voltage Offset Correction: v_off_ini = -205.336 uV, v_off_fin = -209.151 uV 10:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.124 uVs 10:14:49 Integrated Voltage Measurement... 10:14:57 Voltage Offset Correction: v_off_ini = -201.683 uV, v_off_fin = -203.963 uV 10:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.885 uVs 10:14:58 Integrated Voltage Measurement... 10:15:07 Voltage Offset Correction: v_off_ini = -210.877 uV, v_off_fin = -201.101 uV 10:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.352 uVs 10:15:07 Integrated Voltage Measurement... 10:15:16 Voltage Offset Correction: v_off_ini = -214.046 uV, v_off_fin = -202.885 uV 10:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.863 uVs 10:15:16 Integrated Voltage Measurement... 10:15:25 Voltage Offset Correction: v_off_ini = -195.299 uV, v_off_fin = -210.180 uV 10:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.869 uVs 10:15:25 Integrated Voltage Measurement... 10:15:34 Voltage Offset Correction: v_off_ini = -203.612 uV, v_off_fin = -201.850 uV 10:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.455 uVs 10:15:38 I1X Average and RMS of Measurements VT = -126.258 +- 2.393 uVs I1X = 25.252 +- 0.479 uTm 10:15:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:15:45 Integrated Voltage Measurement... 10:15:54 Voltage Offset Correction: v_off_ini = -195.095 uV, v_off_fin = -202.987 uV 10:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.123 uVs 10:15:54 Integrated Voltage Measurement... 10:16:03 Voltage Offset Correction: v_off_ini = -196.129 uV, v_off_fin = -177.528 uV 10:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 166.661 uVs 10:16:03 Integrated Voltage Measurement... 10:16:12 Voltage Offset Correction: v_off_ini = -188.476 uV, v_off_fin = -202.365 uV 10:16:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -142.820 uVs 10:16:12 Integrated Voltage Measurement... 10:16:21 Voltage Offset Correction: v_off_ini = -190.629 uV, v_off_fin = -177.925 uV 10:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 153.783 uVs 10:16:21 Integrated Voltage Measurement... 10:16:30 Voltage Offset Correction: v_off_ini = -184.675 uV, v_off_fin = -179.627 uV 10:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -132.298 uVs 10:16:30 Integrated Voltage Measurement... 10:16:39 Voltage Offset Correction: v_off_ini = -193.133 uV, v_off_fin = -190.017 uV 10:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 152.447 uVs 10:16:43 I1Y Average and RMS of Measurements VT = -149.355 +- 6.177 uVs I1Y = -29.869 +- 1.236 uTm 10:16:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:16:51 Integrated Voltage Measurement... 10:17:00 Voltage Offset Correction: v_off_ini = -215.371 uV, v_off_fin = -224.591 uV 10:17:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -152.171 uVs 10:17:00 Integrated Voltage Measurement... 10:17:09 Voltage Offset Correction: v_off_ini = -222.713 uV, v_off_fin = -212.879 uV 10:17:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.363 uVs 10:17:09 Integrated Voltage Measurement... 10:17:18 Voltage Offset Correction: v_off_ini = -237.813 uV, v_off_fin = -238.906 uV 10:17:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -123.546 uVs 10:17:18 Integrated Voltage Measurement... 10:17:27 Voltage Offset Correction: v_off_ini = -216.980 uV, v_off_fin = -208.374 uV 10:17:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.616 uVs 10:17:27 Integrated Voltage Measurement... 10:17:36 Voltage Offset Correction: v_off_ini = -218.804 uV, v_off_fin = -229.140 uV 10:17:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.270 uVs 10:17:36 Integrated Voltage Measurement... 10:17:45 Voltage Offset Correction: v_off_ini = -226.380 uV, v_off_fin = -226.870 uV 10:17:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.222 uVs 10:17:47 I2X Average and RMS of Measurements VT = -143.531 +- 9.933 uVs I2X = 13.205 +- 0.913 uTm^2 10:17:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:17:55 Integrated Voltage Measurement... 10:18:04 Voltage Offset Correction: v_off_ini = -228.021 uV, v_off_fin = -223.669 uV 10:18:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -205.548 uVs 10:18:04 Integrated Voltage Measurement... 10:18:13 Voltage Offset Correction: v_off_ini = -217.879 uV, v_off_fin = -220.472 uV 10:18:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 202.352 uVs 10:18:13 Integrated Voltage Measurement... 10:18:22 Voltage Offset Correction: v_off_ini = -214.406 uV, v_off_fin = -209.212 uV 10:18:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.133 uVs 10:18:22 Integrated Voltage Measurement... 10:18:31 Voltage Offset Correction: v_off_ini = -219.981 uV, v_off_fin = -215.009 uV 10:18:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.046 uVs 10:18:31 Integrated Voltage Measurement... 10:18:40 Voltage Offset Correction: v_off_ini = -213.805 uV, v_off_fin = -197.506 uV 10:18:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.363 uVs 10:18:40 Integrated Voltage Measurement... 10:18:49 Voltage Offset Correction: v_off_ini = -220.169 uV, v_off_fin = -221.836 uV 10:18:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.233 uVs 10:18:52 I2Y Average and RMS of Measurements VT = -198.612 +- 4.235 uVs I2Y = -18.273 +- 0.390 uTm^2 10:19:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:19:07 Integrated Voltage Measurement... 10:19:16 Voltage Offset Correction: v_off_ini = -224.974 uV, v_off_fin = -218.963 uV 10:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.391 uVs 10:19:16 Integrated Voltage Measurement... 10:19:25 Voltage Offset Correction: v_off_ini = -222.245 uV, v_off_fin = -213.523 uV 10:19:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.983 uVs 10:19:25 Integrated Voltage Measurement... 10:19:34 Voltage Offset Correction: v_off_ini = -229.169 uV, v_off_fin = -225.968 uV 10:19:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.297 uVs 10:19:34 Integrated Voltage Measurement... 10:19:43 Voltage Offset Correction: v_off_ini = -236.309 uV, v_off_fin = -231.734 uV 10:19:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.356 uVs 10:19:43 Integrated Voltage Measurement... 10:19:52 Voltage Offset Correction: v_off_ini = -233.583 uV, v_off_fin = -234.810 uV 10:19:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.989 uVs 10:19:52 Integrated Voltage Measurement... 10:20:01 Voltage Offset Correction: v_off_ini = -235.595 uV, v_off_fin = -234.013 uV 10:20:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.597 uVs 10:20:05 I1X Average and RMS of Measurements VT = -109.935 +- 6.919 uVs I1X = 21.987 +- 1.384 uTm 10:20:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:20:12 Integrated Voltage Measurement... 10:20:21 Voltage Offset Correction: v_off_ini = -214.602 uV, v_off_fin = -215.518 uV 10:20:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.506 uVs 10:20:21 Integrated Voltage Measurement... 10:20:30 Voltage Offset Correction: v_off_ini = -208.628 uV, v_off_fin = -194.322 uV 10:20:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.001 uVs 10:20:30 Integrated Voltage Measurement... 10:20:39 Voltage Offset Correction: v_off_ini = -207.338 uV, v_off_fin = -228.814 uV 10:20:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -143.370 uVs 10:20:39 Integrated Voltage Measurement... 10:20:48 Voltage Offset Correction: v_off_ini = -231.579 uV, v_off_fin = -202.180 uV 10:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.491 uVs 10:20:48 Integrated Voltage Measurement... 10:20:57 Voltage Offset Correction: v_off_ini = -209.422 uV, v_off_fin = -219.570 uV 10:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -155.004 uVs 10:20:57 Integrated Voltage Measurement... 10:21:06 Voltage Offset Correction: v_off_ini = -231.579 uV, v_off_fin = -214.068 uV 10:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.294 uVs 10:21:10 I1Y Average and RMS of Measurements VT = -162.444 +- 3.648 uVs I1Y = -32.486 +- 0.729 uTm 10:21:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:21:18 Integrated Voltage Measurement... 10:21:27 Voltage Offset Correction: v_off_ini = -235.633 uV, v_off_fin = -227.686 uV 10:21:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.069 uVs 10:21:27 Integrated Voltage Measurement... 10:21:36 Voltage Offset Correction: v_off_ini = -222.903 uV, v_off_fin = -206.613 uV 10:21:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 124.260 uVs 10:21:36 Integrated Voltage Measurement... 10:21:45 Voltage Offset Correction: v_off_ini = -218.015 uV, v_off_fin = -224.979 uV 10:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.543 uVs 10:21:45 Integrated Voltage Measurement... 10:21:54 Voltage Offset Correction: v_off_ini = -195.844 uV, v_off_fin = -209.437 uV 10:21:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.797 uVs 10:21:54 Integrated Voltage Measurement... 10:22:03 Voltage Offset Correction: v_off_ini = -212.496 uV, v_off_fin = -232.528 uV 10:22:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -128.572 uVs 10:22:03 Integrated Voltage Measurement... 10:22:12 Voltage Offset Correction: v_off_ini = -227.123 uV, v_off_fin = -215.663 uV 10:22:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.058 uVs 10:22:15 I2X Average and RMS of Measurements VT = -128.217 +- 7.936 uVs I2X = 11.797 +- 0.730 uTm^2 10:22:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:22:22 Integrated Voltage Measurement... 10:22:31 Voltage Offset Correction: v_off_ini = -212.049 uV, v_off_fin = -229.369 uV 10:22:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.058 uVs 10:22:31 Integrated Voltage Measurement... 10:22:40 Voltage Offset Correction: v_off_ini = -229.986 uV, v_off_fin = -202.126 uV 10:22:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.201 uVs 10:22:40 Integrated Voltage Measurement... 10:22:49 Voltage Offset Correction: v_off_ini = -210.544 uV, v_off_fin = -207.220 uV 10:22:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.266 uVs 10:22:49 Integrated Voltage Measurement... 10:22:58 Voltage Offset Correction: v_off_ini = -213.457 uV, v_off_fin = -198.738 uV 10:22:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 208.728 uVs 10:22:59 Integrated Voltage Measurement... 10:23:07 Voltage Offset Correction: v_off_ini = -196.534 uV, v_off_fin = -196.285 uV 10:23:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.479 uVs 10:23:08 Integrated Voltage Measurement... 10:23:17 Voltage Offset Correction: v_off_ini = -189.513 uV, v_off_fin = -184.706 uV 10:23:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.092 uVs 10:23:19 I2Y Average and RMS of Measurements VT = -208.971 +- 1.767 uVs I2Y = -19.226 +- 0.162 uTm^2 10:23:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:23:34 Integrated Voltage Measurement... 10:23:43 Voltage Offset Correction: v_off_ini = -176.563 uV, v_off_fin = -190.286 uV 10:23:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.181 uVs 10:23:43 Integrated Voltage Measurement... 10:23:52 Voltage Offset Correction: v_off_ini = -189.513 uV, v_off_fin = -189.120 uV 10:23:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.110 uVs 10:23:52 Integrated Voltage Measurement... 10:24:01 Voltage Offset Correction: v_off_ini = -170.232 uV, v_off_fin = -173.255 uV 10:24:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.384 uVs 10:24:01 Integrated Voltage Measurement... 10:24:10 Voltage Offset Correction: v_off_ini = -187.107 uV, v_off_fin = -177.288 uV 10:24:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.015 uVs 10:24:10 Integrated Voltage Measurement... 10:24:19 Voltage Offset Correction: v_off_ini = -175.694 uV, v_off_fin = -177.144 uV 10:24:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.904 uVs 10:24:19 Integrated Voltage Measurement... 10:24:28 Voltage Offset Correction: v_off_ini = -173.928 uV, v_off_fin = -186.801 uV 10:24:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.753 uVs 10:24:32 I1X Average and RMS of Measurements VT = -111.891 +- 2.696 uVs I1X = 22.378 +- 0.539 uTm 10:24:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:24:39 Integrated Voltage Measurement... 10:24:48 Voltage Offset Correction: v_off_ini = -180.955 uV, v_off_fin = -193.837 uV 10:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.651 uVs 10:24:48 Integrated Voltage Measurement... 10:24:57 Voltage Offset Correction: v_off_ini = -190.767 uV, v_off_fin = -180.450 uV 10:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.412 uVs 10:24:57 Integrated Voltage Measurement... 10:25:06 Voltage Offset Correction: v_off_ini = -196.823 uV, v_off_fin = -198.566 uV 10:25:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.702 uVs 10:25:06 Integrated Voltage Measurement... 10:25:15 Voltage Offset Correction: v_off_ini = -197.793 uV, v_off_fin = -186.536 uV 10:25:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.568 uVs 10:25:15 Integrated Voltage Measurement... 10:25:24 Voltage Offset Correction: v_off_ini = -197.204 uV, v_off_fin = -214.508 uV 10:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.589 uVs 10:25:24 Integrated Voltage Measurement... 10:25:33 Voltage Offset Correction: v_off_ini = -200.218 uV, v_off_fin = -175.564 uV 10:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.605 uVs 10:25:37 I1Y Average and RMS of Measurements VT = -182.755 +- 3.932 uVs I1Y = -36.547 +- 0.786 uTm 10:25:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:25:45 Integrated Voltage Measurement... 10:25:54 Voltage Offset Correction: v_off_ini = -182.063 uV, v_off_fin = -203.182 uV 10:25:54 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -141.873 uVs 10:25:54 Integrated Voltage Measurement... 10:26:03 Voltage Offset Correction: v_off_ini = -176.911 uV, v_off_fin = -177.040 uV 10:26:03 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 132.344 uVs 10:26:03 Integrated Voltage Measurement... 10:26:12 Voltage Offset Correction: v_off_ini = -192.758 uV, v_off_fin = -210.406 uV 10:26:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.225 uVs 10:26:12 Integrated Voltage Measurement... 10:26:21 Voltage Offset Correction: v_off_ini = -193.470 uV, v_off_fin = -183.670 uV 10:26:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.839 uVs 10:26:21 Integrated Voltage Measurement... 10:26:30 Voltage Offset Correction: v_off_ini = -215.959 uV, v_off_fin = -209.618 uV 10:26:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.274 uVs 10:26:30 Integrated Voltage Measurement... 10:26:39 Voltage Offset Correction: v_off_ini = -201.885 uV, v_off_fin = -198.999 uV 10:26:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.101 uVs 10:26:42 I2X Average and RMS of Measurements VT = -132.943 +- 3.097 uVs I2X = 12.231 +- 0.285 uTm^2 10:26:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:26:49 Integrated Voltage Measurement... 10:26:58 Voltage Offset Correction: v_off_ini = -188.608 uV, v_off_fin = -199.166 uV 10:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.605 uVs 10:26:58 Integrated Voltage Measurement... 10:27:07 Voltage Offset Correction: v_off_ini = -191.477 uV, v_off_fin = -195.854 uV 10:27:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.126 uVs 10:27:07 Integrated Voltage Measurement... 10:27:16 Voltage Offset Correction: v_off_ini = -205.192 uV, v_off_fin = -190.400 uV 10:27:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.062 uVs 10:27:17 Integrated Voltage Measurement... 10:27:25 Voltage Offset Correction: v_off_ini = -192.816 uV, v_off_fin = -183.941 uV 10:27:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.907 uVs 10:27:26 Integrated Voltage Measurement... 10:27:35 Voltage Offset Correction: v_off_ini = -194.954 uV, v_off_fin = -197.076 uV 10:27:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.972 uVs 10:27:35 Integrated Voltage Measurement... 10:27:44 Voltage Offset Correction: v_off_ini = -200.657 uV, v_off_fin = -206.910 uV 10:27:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.719 uVs 10:27:46 I2Y Average and RMS of Measurements VT = -223.399 +- 6.787 uVs I2Y = -20.553 +- 0.624 uTm^2 10:27:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:28:01 Integrated Voltage Measurement... 10:28:10 Voltage Offset Correction: v_off_ini = -212.467 uV, v_off_fin = -213.730 uV 10:28:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.826 uVs 10:28:10 Integrated Voltage Measurement... 10:28:19 Voltage Offset Correction: v_off_ini = -183.042 uV, v_off_fin = -195.505 uV 10:28:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.787 uVs 10:28:19 Integrated Voltage Measurement... 10:28:28 Voltage Offset Correction: v_off_ini = -183.664 uV, v_off_fin = -169.036 uV 10:28:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.171 uVs 10:28:28 Integrated Voltage Measurement... 10:28:37 Voltage Offset Correction: v_off_ini = -194.521 uV, v_off_fin = -194.034 uV 10:28:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.809 uVs 10:28:37 Integrated Voltage Measurement... 10:28:46 Voltage Offset Correction: v_off_ini = -192.905 uV, v_off_fin = -206.443 uV 10:28:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.116 uVs 10:28:46 Integrated Voltage Measurement... 10:28:55 Voltage Offset Correction: v_off_ini = -194.030 uV, v_off_fin = -205.725 uV 10:28:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.747 uVs 10:28:59 I1X Average and RMS of Measurements VT = -97.909 +- 3.412 uVs I1X = 19.582 +- 0.682 uTm 10:29:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:29:06 Integrated Voltage Measurement... 10:29:15 Voltage Offset Correction: v_off_ini = -218.508 uV, v_off_fin = -206.315 uV 10:29:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.819 uVs 10:29:15 Integrated Voltage Measurement... 10:29:24 Voltage Offset Correction: v_off_ini = -205.139 uV, v_off_fin = -190.027 uV 10:29:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.183 uVs 10:29:24 Integrated Voltage Measurement... 10:29:33 Voltage Offset Correction: v_off_ini = -203.867 uV, v_off_fin = -209.940 uV 10:29:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.836 uVs 10:29:33 Integrated Voltage Measurement... 10:29:42 Voltage Offset Correction: v_off_ini = -189.335 uV, v_off_fin = -179.954 uV 10:29:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.065 uVs 10:29:42 Integrated Voltage Measurement... 10:29:51 Voltage Offset Correction: v_off_ini = -204.499 uV, v_off_fin = -207.930 uV 10:29:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.216 uVs 10:29:51 Integrated Voltage Measurement... 10:30:00 Voltage Offset Correction: v_off_ini = -215.467 uV, v_off_fin = -198.177 uV 10:30:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.700 uVs 10:30:04 I1Y Average and RMS of Measurements VT = -194.136 +- 3.663 uVs I1Y = -38.824 +- 0.733 uTm 10:30:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:30:12 Integrated Voltage Measurement... 10:30:20 Voltage Offset Correction: v_off_ini = -223.466 uV, v_off_fin = -238.091 uV 10:30:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -102.845 uVs 10:30:21 Integrated Voltage Measurement... 10:30:29 Voltage Offset Correction: v_off_ini = -223.844 uV, v_off_fin = -207.601 uV 10:30:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.530 uVs 10:30:30 Integrated Voltage Measurement... 10:30:39 Voltage Offset Correction: v_off_ini = -224.602 uV, v_off_fin = -225.641 uV 10:30:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.346 uVs 10:30:39 Integrated Voltage Measurement... 10:30:48 Voltage Offset Correction: v_off_ini = -215.915 uV, v_off_fin = -198.623 uV 10:30:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.348 uVs 10:30:48 Integrated Voltage Measurement... 10:30:57 Voltage Offset Correction: v_off_ini = -209.427 uV, v_off_fin = -223.994 uV 10:30:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.297 uVs 10:30:57 Integrated Voltage Measurement... 10:31:06 Voltage Offset Correction: v_off_ini = -220.731 uV, v_off_fin = -201.845 uV 10:31:06 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 131.499 uVs 10:31:08 I2X Average and RMS of Measurements VT = -117.478 +- 1.660 uVs I2X = 10.808 +- 0.153 uTm^2 10:31:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:31:16 Integrated Voltage Measurement... 10:31:25 Voltage Offset Correction: v_off_ini = -211.037 uV, v_off_fin = -215.171 uV 10:31:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.185 uVs 10:31:25 Integrated Voltage Measurement... 10:31:34 Voltage Offset Correction: v_off_ini = -190.665 uV, v_off_fin = -194.413 uV 10:31:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.017 uVs 10:31:34 Integrated Voltage Measurement... 10:31:43 Voltage Offset Correction: v_off_ini = -195.185 uV, v_off_fin = -197.682 uV 10:31:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.792 uVs 10:31:43 Integrated Voltage Measurement... 10:31:52 Voltage Offset Correction: v_off_ini = -192.310 uV, v_off_fin = -187.767 uV 10:31:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.250 uVs 10:31:52 Integrated Voltage Measurement... 10:32:01 Voltage Offset Correction: v_off_ini = -181.939 uV, v_off_fin = -194.844 uV 10:32:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.907 uVs 10:32:01 Integrated Voltage Measurement... 10:32:10 Voltage Offset Correction: v_off_ini = -209.437 uV, v_off_fin = -201.691 uV 10:32:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.760 uVs 10:32:12 I2Y Average and RMS of Measurements VT = -223.318 +- 6.261 uVs I2Y = -20.545 +- 0.576 uTm^2 10:32:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:32:27 Integrated Voltage Measurement... 10:32:36 Voltage Offset Correction: v_off_ini = -167.972 uV, v_off_fin = -171.651 uV 10:32:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.400 uVs 10:32:36 Integrated Voltage Measurement... 10:32:45 Voltage Offset Correction: v_off_ini = -173.452 uV, v_off_fin = -164.374 uV 10:32:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.168 uVs 10:32:45 Integrated Voltage Measurement... 10:32:54 Voltage Offset Correction: v_off_ini = -165.014 uV, v_off_fin = -176.271 uV 10:32:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.719 uVs 10:32:54 Integrated Voltage Measurement... 10:33:03 Voltage Offset Correction: v_off_ini = -168.452 uV, v_off_fin = -163.977 uV 10:33:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.648 uVs 10:33:03 Integrated Voltage Measurement... 10:33:12 Voltage Offset Correction: v_off_ini = -160.596 uV, v_off_fin = -167.575 uV 10:33:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.912 uVs 10:33:12 Integrated Voltage Measurement... 10:33:21 Voltage Offset Correction: v_off_ini = -156.397 uV, v_off_fin = -158.521 uV 10:33:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.065 uVs 10:33:25 I1X Average and RMS of Measurements VT = -104.486 +- 6.364 uVs I1X = 20.898 +- 1.273 uTm 10:33:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:33:32 Integrated Voltage Measurement... 10:33:41 Voltage Offset Correction: v_off_ini = -172.357 uV, v_off_fin = -183.950 uV 10:33:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.446 uVs 10:33:41 Integrated Voltage Measurement... 10:33:50 Voltage Offset Correction: v_off_ini = -178.900 uV, v_off_fin = -154.122 uV 10:33:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.853 uVs 10:33:50 Integrated Voltage Measurement... 10:33:59 Voltage Offset Correction: v_off_ini = -162.493 uV, v_off_fin = -170.876 uV 10:33:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.397 uVs 10:33:59 Integrated Voltage Measurement... 10:34:08 Voltage Offset Correction: v_off_ini = -155.517 uV, v_off_fin = -155.386 uV 10:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.872 uVs 10:34:08 Integrated Voltage Measurement... 10:34:17 Voltage Offset Correction: v_off_ini = -162.581 uV, v_off_fin = -162.973 uV 10:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.921 uVs 10:34:17 Integrated Voltage Measurement... 10:34:26 Voltage Offset Correction: v_off_ini = -156.014 uV, v_off_fin = -156.684 uV 10:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.582 uVs 10:34:30 I1Y Average and RMS of Measurements VT = -205.345 +- 1.029 uVs I1Y = -41.068 +- 0.207 uTm 10:34:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:34:38 Integrated Voltage Measurement... 10:34:47 Voltage Offset Correction: v_off_ini = -166.487 uV, v_off_fin = -180.483 uV 10:34:47 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.416 uVs 10:34:47 Integrated Voltage Measurement... 10:34:56 Voltage Offset Correction: v_off_ini = -170.846 uV, v_off_fin = -151.795 uV 10:34:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.030 uVs 10:34:56 Integrated Voltage Measurement... 10:35:05 Voltage Offset Correction: v_off_ini = -154.962 uV, v_off_fin = -178.183 uV 10:35:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.329 uVs 10:35:05 Integrated Voltage Measurement... 10:35:14 Voltage Offset Correction: v_off_ini = -165.974 uV, v_off_fin = -149.991 uV 10:35:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.141 uVs 10:35:14 Integrated Voltage Measurement... 10:35:23 Voltage Offset Correction: v_off_ini = -169.949 uV, v_off_fin = -177.637 uV 10:35:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.976 uVs 10:35:23 Integrated Voltage Measurement... 10:35:32 Voltage Offset Correction: v_off_ini = -163.101 uV, v_off_fin = -161.695 uV 10:35:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.251 uVs 10:35:34 I2X Average and RMS of Measurements VT = -116.857 +- 5.846 uVs I2X = 10.751 +- 0.538 uTm^2 10:35:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:35:42 Integrated Voltage Measurement... 10:35:51 Voltage Offset Correction: v_off_ini = -188.557 uV, v_off_fin = -171.351 uV 10:35:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.304 uVs 10:35:51 Integrated Voltage Measurement... 10:36:00 Voltage Offset Correction: v_off_ini = -175.709 uV, v_off_fin = -167.703 uV 10:36:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.774 uVs 10:36:00 Integrated Voltage Measurement... 10:36:09 Voltage Offset Correction: v_off_ini = -157.476 uV, v_off_fin = -156.769 uV 10:36:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.304 uVs 10:36:09 Integrated Voltage Measurement... 10:36:18 Voltage Offset Correction: v_off_ini = -170.200 uV, v_off_fin = -172.744 uV 10:36:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.974 uVs 10:36:18 Integrated Voltage Measurement... 10:36:27 Voltage Offset Correction: v_off_ini = -180.565 uV, v_off_fin = -165.695 uV 10:36:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.281 uVs 10:36:27 Integrated Voltage Measurement... 10:36:36 Voltage Offset Correction: v_off_ini = -162.696 uV, v_off_fin = -161.251 uV 10:36:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.693 uVs 10:36:38 I2Y Average and RMS of Measurements VT = -233.388 +- 10.250 uVs I2Y = -21.472 +- 0.943 uTm^2 10:36:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:36:53 Integrated Voltage Measurement... 10:37:02 Voltage Offset Correction: v_off_ini = -163.988 uV, v_off_fin = -161.121 uV 10:37:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.012 uVs 10:37:02 Integrated Voltage Measurement... 10:37:11 Voltage Offset Correction: v_off_ini = -165.065 uV, v_off_fin = -155.568 uV 10:37:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.493 uVs 10:37:11 Integrated Voltage Measurement... 10:37:20 Voltage Offset Correction: v_off_ini = -140.243 uV, v_off_fin = -158.983 uV 10:37:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.453 uVs 10:37:20 Integrated Voltage Measurement... 10:37:29 Voltage Offset Correction: v_off_ini = -148.135 uV, v_off_fin = -138.268 uV 10:37:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.801 uVs 10:37:29 Integrated Voltage Measurement... 10:37:38 Voltage Offset Correction: v_off_ini = -155.077 uV, v_off_fin = -154.348 uV 10:37:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.564 uVs 10:37:38 Integrated Voltage Measurement... 10:37:47 Voltage Offset Correction: v_off_ini = -144.329 uV, v_off_fin = -150.274 uV 10:37:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.378 uVs 10:37:52 I1X Average and RMS of Measurements VT = -94.117 +- 11.933 uVs I1X = 18.824 +- 2.387 uTm 10:37:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:37:58 Integrated Voltage Measurement... 10:38:07 Voltage Offset Correction: v_off_ini = -156.224 uV, v_off_fin = -159.392 uV 10:38:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.734 uVs 10:38:07 Integrated Voltage Measurement... 10:38:16 Voltage Offset Correction: v_off_ini = -152.943 uV, v_off_fin = -140.433 uV 10:38:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 217.961 uVs 10:38:16 Integrated Voltage Measurement... 10:38:25 Voltage Offset Correction: v_off_ini = -152.059 uV, v_off_fin = -158.722 uV 10:38:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -204.543 uVs 10:38:25 Integrated Voltage Measurement... 10:38:34 Voltage Offset Correction: v_off_ini = -143.220 uV, v_off_fin = -137.626 uV 10:38:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.705 uVs 10:38:34 Integrated Voltage Measurement... 10:38:43 Voltage Offset Correction: v_off_ini = -149.232 uV, v_off_fin = -150.058 uV 10:38:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.200 uVs 10:38:43 Integrated Voltage Measurement... 10:38:52 Voltage Offset Correction: v_off_ini = -144.424 uV, v_off_fin = -139.969 uV 10:38:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.773 uVs 10:38:57 I1Y Average and RMS of Measurements VT = -206.986 +- 2.636 uVs I1Y = -41.394 +- 0.529 uTm 10:39:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:39:04 Integrated Voltage Measurement... 10:39:13 Voltage Offset Correction: v_off_ini = -156.655 uV, v_off_fin = -166.706 uV 10:39:13 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -124.738 uVs 10:39:13 Integrated Voltage Measurement... 10:39:22 Voltage Offset Correction: v_off_ini = -154.149 uV, v_off_fin = -132.734 uV 10:39:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.061 uVs 10:39:22 Integrated Voltage Measurement... 10:39:31 Voltage Offset Correction: v_off_ini = -147.759 uV, v_off_fin = -159.819 uV 10:39:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.563 uVs 10:39:31 Integrated Voltage Measurement... 10:39:40 Voltage Offset Correction: v_off_ini = -153.820 uV, v_off_fin = -130.793 uV 10:39:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.830 uVs 10:39:40 Integrated Voltage Measurement... 10:39:49 Voltage Offset Correction: v_off_ini = -127.356 uV, v_off_fin = -148.832 uV 10:39:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.157 uVs 10:39:49 Integrated Voltage Measurement... 10:39:58 Voltage Offset Correction: v_off_ini = -132.553 uV, v_off_fin = -129.316 uV 10:39:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.383 uVs 10:40:01 I2X Average and RMS of Measurements VT = -119.955 +- 2.319 uVs I2X = 11.036 +- 0.213 uTm^2 10:40:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:40:08 Integrated Voltage Measurement... 10:40:17 Voltage Offset Correction: v_off_ini = -148.193 uV, v_off_fin = -142.722 uV 10:40:17 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -234.792 uVs 10:40:17 Integrated Voltage Measurement... 10:40:26 Voltage Offset Correction: v_off_ini = -142.791 uV, v_off_fin = -136.739 uV 10:40:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.783 uVs 10:40:26 Integrated Voltage Measurement... 10:40:35 Voltage Offset Correction: v_off_ini = -144.367 uV, v_off_fin = -140.420 uV 10:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.184 uVs 10:40:35 Integrated Voltage Measurement... 10:40:44 Voltage Offset Correction: v_off_ini = -158.668 uV, v_off_fin = -154.198 uV 10:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.320 uVs 10:40:44 Integrated Voltage Measurement... 10:40:53 Voltage Offset Correction: v_off_ini = -151.559 uV, v_off_fin = -154.373 uV 10:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.765 uVs 10:40:53 Integrated Voltage Measurement... 10:41:02 Voltage Offset Correction: v_off_ini = -132.412 uV, v_off_fin = -131.335 uV 10:41:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.420 uVs 10:41:05 I2Y Average and RMS of Measurements VT = -234.877 +- 2.130 uVs I2Y = -21.608 +- 0.195 uTm^2 10:41:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:41:20 Integrated Voltage Measurement... 10:41:29 Voltage Offset Correction: v_off_ini = -120.411 uV, v_off_fin = -137.964 uV 10:41:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.507 uVs 10:41:29 Integrated Voltage Measurement... 10:41:38 Voltage Offset Correction: v_off_ini = -128.831 uV, v_off_fin = -136.018 uV 10:41:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.720 uVs 10:41:38 Integrated Voltage Measurement... 10:41:47 Voltage Offset Correction: v_off_ini = -145.445 uV, v_off_fin = -129.042 uV 10:41:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.900 uVs 10:41:47 Integrated Voltage Measurement... 10:41:56 Voltage Offset Correction: v_off_ini = -114.642 uV, v_off_fin = -100.696 uV 10:41:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.259 uVs 10:41:56 Integrated Voltage Measurement... 10:42:05 Voltage Offset Correction: v_off_ini = -111.864 uV, v_off_fin = -123.531 uV 10:42:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.518 uVs 10:42:05 Integrated Voltage Measurement... 10:42:14 Voltage Offset Correction: v_off_ini = -107.658 uV, v_off_fin = -104.961 uV 10:42:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.943 uVs 10:42:18 I1X Average and RMS of Measurements VT = -86.974 +- 10.389 uVs I1X = 17.396 +- 2.078 uTm 10:42:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:42:25 Integrated Voltage Measurement... 10:42:34 Voltage Offset Correction: v_off_ini = -102.129 uV, v_off_fin = -134.968 uV 10:42:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.390 uVs 10:42:34 Integrated Voltage Measurement... 10:42:43 Voltage Offset Correction: v_off_ini = -119.986 uV, v_off_fin = -108.627 uV 10:42:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.997 uVs 10:42:43 Integrated Voltage Measurement... 10:42:52 Voltage Offset Correction: v_off_ini = -111.898 uV, v_off_fin = -127.573 uV 10:42:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.366 uVs 10:42:52 Integrated Voltage Measurement... 10:43:01 Voltage Offset Correction: v_off_ini = -119.525 uV, v_off_fin = -106.019 uV 10:43:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 222.523 uVs 10:43:01 Integrated Voltage Measurement... 10:43:10 Voltage Offset Correction: v_off_ini = -116.122 uV, v_off_fin = -127.294 uV 10:43:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -210.840 uVs 10:43:10 Integrated Voltage Measurement... 10:43:19 Voltage Offset Correction: v_off_ini = -107.788 uV, v_off_fin = -91.838 uV 10:43:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 234.484 uVs 10:43:23 I1Y Average and RMS of Measurements VT = -216.933 +- 5.140 uVs I1Y = -43.380 +- 1.026 uTm 10:43:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:43:31 Integrated Voltage Measurement... 10:43:40 Voltage Offset Correction: v_off_ini = -116.174 uV, v_off_fin = -123.812 uV 10:43:40 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -112.346 uVs 10:43:40 Integrated Voltage Measurement... 10:43:49 Voltage Offset Correction: v_off_ini = -115.231 uV, v_off_fin = -105.408 uV 10:43:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.127 uVs 10:43:49 Integrated Voltage Measurement... 10:43:58 Voltage Offset Correction: v_off_ini = -122.589 uV, v_off_fin = -123.706 uV 10:43:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.488 uVs 10:43:58 Integrated Voltage Measurement... 10:44:07 Voltage Offset Correction: v_off_ini = -100.735 uV, v_off_fin = -100.478 uV 10:44:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.149 uVs 10:44:07 Integrated Voltage Measurement... 10:44:16 Voltage Offset Correction: v_off_ini = -102.977 uV, v_off_fin = -115.484 uV 10:44:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.435 uVs 10:44:16 Integrated Voltage Measurement... 10:44:25 Voltage Offset Correction: v_off_ini = -103.608 uV, v_off_fin = -77.715 uV 10:44:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.968 uVs 10:44:27 I2X Average and RMS of Measurements VT = -113.252 +- 2.902 uVs I2X = 10.419 +- 0.267 uTm^2 10:44:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:44:35 Integrated Voltage Measurement... 10:44:44 Voltage Offset Correction: v_off_ini = -88.759 uV, v_off_fin = -95.693 uV 10:44:44 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -263.978 uVs 10:44:44 Integrated Voltage Measurement... 10:44:53 Voltage Offset Correction: v_off_ini = -93.316 uV, v_off_fin = -86.585 uV 10:44:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.534 uVs 10:44:53 Integrated Voltage Measurement... 10:45:02 Voltage Offset Correction: v_off_ini = -95.514 uV, v_off_fin = -92.481 uV 10:45:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.279 uVs 10:45:02 Integrated Voltage Measurement... 10:45:11 Voltage Offset Correction: v_off_ini = -98.065 uV, v_off_fin = -94.461 uV 10:45:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.208 uVs 10:45:11 Integrated Voltage Measurement... 10:45:20 Voltage Offset Correction: v_off_ini = -92.895 uV, v_off_fin = -91.449 uV 10:45:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.287 uVs 10:45:20 Integrated Voltage Measurement... 10:45:29 Voltage Offset Correction: v_off_ini = -81.227 uV, v_off_fin = -84.257 uV 10:45:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.635 uVs 10:45:32 I2Y Average and RMS of Measurements VT = -258.487 +- 6.948 uVs I2Y = -23.780 +- 0.639 uTm^2 10:45:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:45:47 Integrated Voltage Measurement... 10:45:56 Voltage Offset Correction: v_off_ini = -62.958 uV, v_off_fin = -60.394 uV 10:45:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -94.168 uVs 10:45:56 Integrated Voltage Measurement... 10:46:05 Voltage Offset Correction: v_off_ini = -68.568 uV, v_off_fin = -60.379 uV 10:46:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.716 uVs 10:46:05 Integrated Voltage Measurement... 10:46:14 Voltage Offset Correction: v_off_ini = -65.721 uV, v_off_fin = -70.730 uV 10:46:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.935 uVs 10:46:14 Integrated Voltage Measurement... 10:46:23 Voltage Offset Correction: v_off_ini = -82.048 uV, v_off_fin = -71.219 uV 10:46:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.778 uVs 10:46:23 Integrated Voltage Measurement... 10:46:32 Voltage Offset Correction: v_off_ini = -71.498 uV, v_off_fin = -80.250 uV 10:46:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.388 uVs 10:46:32 Integrated Voltage Measurement... 10:46:41 Voltage Offset Correction: v_off_ini = -75.149 uV, v_off_fin = -68.391 uV 10:46:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.870 uVs 10:46:45 I1X Average and RMS of Measurements VT = -96.476 +- 3.338 uVs I1X = 19.296 +- 0.668 uTm 10:46:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:46:52 Integrated Voltage Measurement... 10:47:01 Voltage Offset Correction: v_off_ini = -87.761 uV, v_off_fin = -87.170 uV 10:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.938 uVs 10:47:01 Integrated Voltage Measurement... 10:47:10 Voltage Offset Correction: v_off_ini = -76.694 uV, v_off_fin = -49.181 uV 10:47:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.668 uVs 10:47:10 Integrated Voltage Measurement... 10:47:19 Voltage Offset Correction: v_off_ini = -68.141 uV, v_off_fin = -71.864 uV 10:47:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.365 uVs 10:47:19 Integrated Voltage Measurement... 10:47:28 Voltage Offset Correction: v_off_ini = -67.050 uV, v_off_fin = -57.114 uV 10:47:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.181 uVs 10:47:28 Integrated Voltage Measurement... 10:47:37 Voltage Offset Correction: v_off_ini = -72.176 uV, v_off_fin = -81.416 uV 10:47:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.260 uVs 10:47:37 Integrated Voltage Measurement... 10:47:46 Voltage Offset Correction: v_off_ini = -49.109 uV, v_off_fin = -52.028 uV 10:47:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.669 uVs 10:47:50 I1Y Average and RMS of Measurements VT = -224.680 +- 4.823 uVs I1Y = -44.934 +- 0.965 uTm 10:47:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:47:58 Integrated Voltage Measurement... 10:48:07 Voltage Offset Correction: v_off_ini = -33.277 uV, v_off_fin = -50.821 uV 10:48:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -124.883 uVs 10:48:07 Integrated Voltage Measurement... 10:48:16 Voltage Offset Correction: v_off_ini = -23.035 uV, v_off_fin = -17.545 uV 10:48:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.081 uVs 10:48:16 Integrated Voltage Measurement... 10:48:25 Voltage Offset Correction: v_off_ini = -35.946 uV, v_off_fin = -32.226 uV 10:48:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.783 uVs 10:48:25 Integrated Voltage Measurement... 10:48:34 Voltage Offset Correction: v_off_ini = -29.995 uV, v_off_fin = -29.211 uV 10:48:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.505 uVs 10:48:34 Integrated Voltage Measurement... 10:48:43 Voltage Offset Correction: v_off_ini = -34.794 uV, v_off_fin = -41.711 uV 10:48:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.961 uVs 10:48:43 Integrated Voltage Measurement... 10:48:52 Voltage Offset Correction: v_off_ini = -51.556 uV, v_off_fin = -20.533 uV 10:48:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.420 uVs 10:48:55 I2X Average and RMS of Measurements VT = -121.772 +- 8.604 uVs I2X = 11.203 +- 0.791 uTm^2 10:49:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:49:02 Integrated Voltage Measurement... 10:49:11 Voltage Offset Correction: v_off_ini = -37.999 uV, v_off_fin = -54.105 uV 10:49:11 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -255.838 uVs 10:49:11 Integrated Voltage Measurement... 10:49:20 Voltage Offset Correction: v_off_ini = -30.893 uV, v_off_fin = -45.107 uV 10:49:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.446 uVs 10:49:20 Integrated Voltage Measurement... 10:49:29 Voltage Offset Correction: v_off_ini = -34.318 uV, v_off_fin = -45.770 uV 10:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.963 uVs 10:49:30 Integrated Voltage Measurement... 10:49:38 Voltage Offset Correction: v_off_ini = -50.892 uV, v_off_fin = -49.274 uV 10:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.698 uVs 10:49:39 Integrated Voltage Measurement... 10:49:48 Voltage Offset Correction: v_off_ini = -44.993 uV, v_off_fin = -48.237 uV 10:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.675 uVs 10:49:48 Integrated Voltage Measurement... 10:49:57 Voltage Offset Correction: v_off_ini = -31.769 uV, v_off_fin = -28.878 uV 10:49:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.838 uVs 10:49:59 I2Y Average and RMS of Measurements VT = -254.910 +- 2.168 uVs I2Y = -23.451 +- 0.200 uTm^2 10:50:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:14 Integrated Voltage Measurement... 10:50:23 Voltage Offset Correction: v_off_ini = -16.614 uV, v_off_fin = -32.708 uV 10:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.088 uVs 10:50:23 Integrated Voltage Measurement... 10:50:32 Voltage Offset Correction: v_off_ini = -13.777 uV, v_off_fin = -35.046 uV 10:50:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.018 uVs 10:50:32 Integrated Voltage Measurement... 10:50:41 Voltage Offset Correction: v_off_ini = -26.201 uV, v_off_fin = -33.824 uV 10:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.797 uVs 10:50:41 Integrated Voltage Measurement... 10:50:50 Voltage Offset Correction: v_off_ini = -27.758 uV, v_off_fin = -31.008 uV 10:50:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.273 uVs 10:50:50 Integrated Voltage Measurement... 10:50:59 Voltage Offset Correction: v_off_ini = -36.355 uV, v_off_fin = -35.688 uV 10:50:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.510 uVs 10:50:59 Integrated Voltage Measurement... 10:51:08 Voltage Offset Correction: v_off_ini = -37.156 uV, v_off_fin = -31.286 uV 10:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.160 uVs 10:51:12 I1X Average and RMS of Measurements VT = -88.308 +- 7.440 uVs I1X = 17.662 +- 1.488 uTm 10:51:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:19 Integrated Voltage Measurement... 10:51:28 Voltage Offset Correction: v_off_ini = -47.836 uV, v_off_fin = -57.910 uV 10:51:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.909 uVs 10:51:28 Integrated Voltage Measurement... 10:51:37 Voltage Offset Correction: v_off_ini = -35.210 uV, v_off_fin = -19.850 uV 10:51:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 244.109 uVs 10:51:37 Integrated Voltage Measurement... 10:51:46 Voltage Offset Correction: v_off_ini = -45.540 uV, v_off_fin = -45.448 uV 10:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -218.291 uVs 10:51:46 Integrated Voltage Measurement... 10:51:55 Voltage Offset Correction: v_off_ini = -48.425 uV, v_off_fin = -31.175 uV 10:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 229.309 uVs 10:51:55 Integrated Voltage Measurement... 10:52:04 Voltage Offset Correction: v_off_ini = -35.788 uV, v_off_fin = -34.112 uV 10:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.188 uVs 10:52:04 Integrated Voltage Measurement... 10:52:13 Voltage Offset Correction: v_off_ini = -34.348 uV, v_off_fin = -21.957 uV 10:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.226 uVs 10:52:17 I1Y Average and RMS of Measurements VT = -230.672 +- 4.860 uVs I1Y = -46.127 +- 0.973 uTm 10:52:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:25 Integrated Voltage Measurement... 10:52:34 Voltage Offset Correction: v_off_ini = -22.230 uV, v_off_fin = -24.376 uV 10:52:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -121.938 uVs 10:52:34 Integrated Voltage Measurement... 10:52:43 Voltage Offset Correction: v_off_ini = -35.200 uV, v_off_fin = -18.198 uV 10:52:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.902 uVs 10:52:43 Integrated Voltage Measurement... 10:52:52 Voltage Offset Correction: v_off_ini = -26.615 uV, v_off_fin = -27.669 uV 10:52:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.270 uVs 10:52:52 Integrated Voltage Measurement... 10:53:01 Voltage Offset Correction: v_off_ini = -35.720 uV, v_off_fin = -26.498 uV 10:53:01 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 105.511 uVs 10:53:01 Integrated Voltage Measurement... 10:53:10 Voltage Offset Correction: v_off_ini = -36.957 uV, v_off_fin = -46.915 uV 10:53:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.896 uVs 10:53:10 Integrated Voltage Measurement... 10:53:19 Voltage Offset Correction: v_off_ini = -17.670 uV, v_off_fin = -20.175 uV 10:53:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.468 uVs 10:53:22 I2X Average and RMS of Measurements VT = -105.497 +- 5.138 uVs I2X = 9.706 +- 0.472 uTm^2 10:53:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:29 Integrated Voltage Measurement... 10:53:38 Voltage Offset Correction: v_off_ini = -40.006 uV, v_off_fin = -41.456 uV 10:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.251 uVs 10:53:38 Integrated Voltage Measurement... 10:53:47 Voltage Offset Correction: v_off_ini = -36.090 uV, v_off_fin = -32.895 uV 10:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.326 uVs 10:53:47 Integrated Voltage Measurement... 10:53:56 Voltage Offset Correction: v_off_ini = -43.128 uV, v_off_fin = -41.581 uV 10:53:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.057 uVs 10:53:57 Integrated Voltage Measurement... 10:54:06 Voltage Offset Correction: v_off_ini = -28.990 uV, v_off_fin = -36.946 uV 10:54:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.017 uVs 10:54:06 Integrated Voltage Measurement... 10:54:15 Voltage Offset Correction: v_off_ini = -46.974 uV, v_off_fin = -48.693 uV 10:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.164 uVs 10:54:15 Integrated Voltage Measurement... 10:54:24 Voltage Offset Correction: v_off_ini = -60.665 uV, v_off_fin = -39.171 uV 10:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.883 uVs 10:54:26 I2Y Average and RMS of Measurements VT = -256.783 +- 6.232 uVs I2Y = -23.624 +- 0.573 uTm^2 10:54:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:54:41 Integrated Voltage Measurement... 10:54:50 Voltage Offset Correction: v_off_ini = -32.988 uV, v_off_fin = -34.857 uV 10:54:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.998 uVs 10:54:50 Integrated Voltage Measurement... 10:54:59 Voltage Offset Correction: v_off_ini = -37.461 uV, v_off_fin = -32.216 uV 10:54:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.344 uVs 10:54:59 Integrated Voltage Measurement... 10:55:08 Voltage Offset Correction: v_off_ini = -53.725 uV, v_off_fin = -46.745 uV 10:55:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.713 uVs 10:55:08 Integrated Voltage Measurement... 10:55:17 Voltage Offset Correction: v_off_ini = -31.318 uV, v_off_fin = -45.309 uV 10:55:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.523 uVs 10:55:17 Integrated Voltage Measurement... 10:55:26 Voltage Offset Correction: v_off_ini = -43.797 uV, v_off_fin = -55.677 uV 10:55:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.717 uVs 10:55:26 Integrated Voltage Measurement... 10:55:35 Voltage Offset Correction: v_off_ini = -44.141 uV, v_off_fin = -49.883 uV 10:55:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.972 uVs 10:55:40 I1X Average and RMS of Measurements VT = -85.211 +- 4.237 uVs I1X = 17.042 +- 0.847 uTm 10:55:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:55:46 Integrated Voltage Measurement... 10:55:55 Voltage Offset Correction: v_off_ini = -45.100 uV, v_off_fin = -62.214 uV 10:55:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -213.598 uVs 10:55:55 Integrated Voltage Measurement... 10:56:04 Voltage Offset Correction: v_off_ini = -54.997 uV, v_off_fin = -33.285 uV 10:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.755 uVs 10:56:04 Integrated Voltage Measurement... 10:56:13 Voltage Offset Correction: v_off_ini = -50.872 uV, v_off_fin = -59.703 uV 10:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.677 uVs 10:56:13 Integrated Voltage Measurement... 10:56:22 Voltage Offset Correction: v_off_ini = -59.750 uV, v_off_fin = -38.512 uV 10:56:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 244.638 uVs 10:56:22 Integrated Voltage Measurement... 10:56:31 Voltage Offset Correction: v_off_ini = -60.424 uV, v_off_fin = -64.846 uV 10:56:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.156 uVs 10:56:31 Integrated Voltage Measurement... 10:56:40 Voltage Offset Correction: v_off_ini = -48.792 uV, v_off_fin = -30.508 uV 10:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.554 uVs 10:56:45 I1Y Average and RMS of Measurements VT = -229.230 +- 5.741 uVs I1Y = -45.843 +- 1.146 uTm 10:56:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:52 Integrated Voltage Measurement... 10:57:01 Voltage Offset Correction: v_off_ini = -54.627 uV, v_off_fin = -51.004 uV 10:57:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.256 uVs 10:57:01 Integrated Voltage Measurement... 10:57:10 Voltage Offset Correction: v_off_ini = -44.216 uV, v_off_fin = -27.539 uV 10:57:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.962 uVs 10:57:10 Integrated Voltage Measurement... 10:57:19 Voltage Offset Correction: v_off_ini = -34.678 uV, v_off_fin = -52.458 uV 10:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.755 uVs 10:57:19 Integrated Voltage Measurement... 10:57:28 Voltage Offset Correction: v_off_ini = -31.122 uV, v_off_fin = -23.155 uV 10:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.953 uVs 10:57:29 Integrated Voltage Measurement... 10:57:38 Voltage Offset Correction: v_off_ini = -53.879 uV, v_off_fin = -64.013 uV 10:57:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.922 uVs 10:57:38 Integrated Voltage Measurement... 10:57:47 Voltage Offset Correction: v_off_ini = -54.863 uV, v_off_fin = -40.026 uV 10:57:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.599 uVs 10:57:49 I2X Average and RMS of Measurements VT = -112.241 +- 4.647 uVs I2X = 10.326 +- 0.428 uTm^2 10:57:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:57:57 Integrated Voltage Measurement... 10:58:06 Voltage Offset Correction: v_off_ini = -39.381 uV, v_off_fin = -40.688 uV 10:58:06 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -247.215 uVs 10:58:06 Integrated Voltage Measurement... 10:58:15 Voltage Offset Correction: v_off_ini = -43.535 uV, v_off_fin = -61.327 uV 10:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.033 uVs 10:58:15 Integrated Voltage Measurement... 10:58:24 Voltage Offset Correction: v_off_ini = -67.022 uV, v_off_fin = -68.039 uV 10:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.642 uVs 10:58:24 Integrated Voltage Measurement... 10:58:33 Voltage Offset Correction: v_off_ini = -58.393 uV, v_off_fin = -49.886 uV 10:58:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.043 uVs 10:58:33 Integrated Voltage Measurement... 10:58:42 Voltage Offset Correction: v_off_ini = -58.353 uV, v_off_fin = -61.042 uV 10:58:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.674 uVs 10:58:42 Integrated Voltage Measurement... 10:58:51 Voltage Offset Correction: v_off_ini = -41.228 uV, v_off_fin = -49.761 uV 10:58:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.873 uVs 10:58:53 I2Y Average and RMS of Measurements VT = -261.580 +- 8.852 uVs I2Y = -24.065 +- 0.815 uTm^2 10:59:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:59:09 Integrated Voltage Measurement... 10:59:18 Voltage Offset Correction: v_off_ini = -50.559 uV, v_off_fin = -64.292 uV 10:59:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -98.187 uVs 10:59:19 Integrated Voltage Measurement... 10:59:27 Voltage Offset Correction: v_off_ini = -74.664 uV, v_off_fin = -67.650 uV 10:59:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.867 uVs 10:59:28 Integrated Voltage Measurement... 10:59:36 Voltage Offset Correction: v_off_ini = -72.892 uV, v_off_fin = -72.215 uV 10:59:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.871 uVs 10:59:37 Integrated Voltage Measurement... 10:59:45 Voltage Offset Correction: v_off_ini = -86.349 uV, v_off_fin = -65.202 uV 10:59:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.841 uVs 10:59:46 Integrated Voltage Measurement... 10:59:54 Voltage Offset Correction: v_off_ini = -78.739 uV, v_off_fin = -64.919 uV 10:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.052 uVs 10:59:55 Integrated Voltage Measurement... 11:00:03 Voltage Offset Correction: v_off_ini = -83.344 uV, v_off_fin = -69.163 uV 11:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.332 uVs 11:00:08 I1X Average and RMS of Measurements VT = -91.358 +- 4.844 uVs I1X = 18.273 +- 0.970 uTm 11:00:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:00:14 Integrated Voltage Measurement... 11:00:23 Voltage Offset Correction: v_off_ini = -80.988 uV, v_off_fin = -94.135 uV 11:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.010 uVs 11:00:24 Integrated Voltage Measurement... 11:00:32 Voltage Offset Correction: v_off_ini = -67.075 uV, v_off_fin = -52.619 uV 11:00:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.383 uVs 11:00:33 Integrated Voltage Measurement... 11:00:41 Voltage Offset Correction: v_off_ini = -76.305 uV, v_off_fin = -88.781 uV 11:00:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.845 uVs 11:00:41 Integrated Voltage Measurement... 11:00:50 Voltage Offset Correction: v_off_ini = -85.906 uV, v_off_fin = -63.467 uV 11:00:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.466 uVs 11:00:51 Integrated Voltage Measurement... 11:01:00 Voltage Offset Correction: v_off_ini = -86.587 uV, v_off_fin = -92.227 uV 11:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.189 uVs 11:01:00 Integrated Voltage Measurement... 11:01:09 Voltage Offset Correction: v_off_ini = -86.160 uV, v_off_fin = -68.301 uV 11:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.305 uVs 11:01:13 I1Y Average and RMS of Measurements VT = -241.533 +- 7.841 uVs I1Y = -48.303 +- 1.568 uTm 11:01:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:20 Integrated Voltage Measurement... 11:01:29 Voltage Offset Correction: v_off_ini = -88.733 uV, v_off_fin = -90.339 uV 11:01:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.220 uVs 11:01:30 Integrated Voltage Measurement... 11:01:39 Voltage Offset Correction: v_off_ini = -84.206 uV, v_off_fin = -90.195 uV 11:01:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.284 uVs 11:01:39 Integrated Voltage Measurement... 11:01:48 Voltage Offset Correction: v_off_ini = -107.344 uV, v_off_fin = -111.035 uV 11:01:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.767 uVs 11:01:48 Integrated Voltage Measurement... 11:01:57 Voltage Offset Correction: v_off_ini = -87.035 uV, v_off_fin = -79.959 uV 11:01:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.327 uVs 11:01:57 Integrated Voltage Measurement... 11:02:06 Voltage Offset Correction: v_off_ini = -93.146 uV, v_off_fin = -101.000 uV 11:02:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.482 uVs 11:02:06 Integrated Voltage Measurement... 11:02:15 Voltage Offset Correction: v_off_ini = -99.540 uV, v_off_fin = -84.910 uV 11:02:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.373 uVs 11:02:17 I2X Average and RMS of Measurements VT = -97.075 +- 6.546 uVs I2X = 8.931 +- 0.602 uTm^2 11:02:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:25 Integrated Voltage Measurement... 11:02:34 Voltage Offset Correction: v_off_ini = -116.627 uV, v_off_fin = -107.253 uV 11:02:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.901 uVs 11:02:34 Integrated Voltage Measurement... 11:02:43 Voltage Offset Correction: v_off_ini = -106.283 uV, v_off_fin = -91.951 uV 11:02:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.286 uVs 11:02:43 Integrated Voltage Measurement... 11:02:52 Voltage Offset Correction: v_off_ini = -82.840 uV, v_off_fin = -93.148 uV 11:02:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.477 uVs 11:02:52 Integrated Voltage Measurement... 11:03:01 Voltage Offset Correction: v_off_ini = -103.490 uV, v_off_fin = -86.594 uV 11:03:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.542 uVs 11:03:01 Integrated Voltage Measurement... 11:03:10 Voltage Offset Correction: v_off_ini = -74.989 uV, v_off_fin = -99.242 uV 11:03:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.583 uVs 11:03:10 Integrated Voltage Measurement... 11:03:19 Voltage Offset Correction: v_off_ini = -94.493 uV, v_off_fin = -95.155 uV 11:03:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.708 uVs 11:03:22 I2Y Average and RMS of Measurements VT = -268.916 +- 3.451 uVs I2Y = -24.740 +- 0.317 uTm^2 11:03:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:03:38 Integrated Voltage Measurement... 11:03:47 Voltage Offset Correction: v_off_ini = -80.690 uV, v_off_fin = -87.202 uV 11:03:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.735 uVs 11:03:47 Integrated Voltage Measurement... 11:03:56 Voltage Offset Correction: v_off_ini = -100.463 uV, v_off_fin = -93.008 uV 11:03:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.924 uVs 11:03:56 Integrated Voltage Measurement... 11:04:05 Voltage Offset Correction: v_off_ini = -101.817 uV, v_off_fin = -91.319 uV 11:04:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.276 uVs 11:04:05 Integrated Voltage Measurement... 11:04:14 Voltage Offset Correction: v_off_ini = -85.909 uV, v_off_fin = -89.298 uV 11:04:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.276 uVs 11:04:14 Integrated Voltage Measurement... 11:04:23 Voltage Offset Correction: v_off_ini = -96.667 uV, v_off_fin = -103.902 uV 11:04:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.862 uVs 11:04:23 Integrated Voltage Measurement... 11:04:32 Voltage Offset Correction: v_off_ini = -92.297 uV, v_off_fin = -87.803 uV 11:04:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.907 uVs 11:04:36 I1X Average and RMS of Measurements VT = -93.830 +- 9.036 uVs I1X = 18.766 +- 1.807 uTm 11:04:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:04:43 Integrated Voltage Measurement... 11:04:52 Voltage Offset Correction: v_off_ini = -81.143 uV, v_off_fin = -70.488 uV 11:04:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.947 uVs 11:04:52 Integrated Voltage Measurement... 11:05:01 Voltage Offset Correction: v_off_ini = -62.105 uV, v_off_fin = -54.950 uV 11:05:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.067 uVs 11:05:01 Integrated Voltage Measurement... 11:05:10 Voltage Offset Correction: v_off_ini = -32.784 uV, v_off_fin = -68.613 uV 11:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.792 uVs 11:05:10 Integrated Voltage Measurement... 11:05:19 Voltage Offset Correction: v_off_ini = -60.283 uV, v_off_fin = -51.384 uV 11:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.439 uVs 11:05:19 Integrated Voltage Measurement... 11:05:28 Voltage Offset Correction: v_off_ini = -60.589 uV, v_off_fin = -76.159 uV 11:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.422 uVs 11:05:28 Integrated Voltage Measurement... 11:05:37 Voltage Offset Correction: v_off_ini = -67.511 uV, v_off_fin = -46.742 uV 11:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 246.471 uVs 11:05:41 I1Y Average and RMS of Measurements VT = -240.856 +- 4.062 uVs I1Y = -48.167 +- 0.811 uTm 11:05:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:49 Integrated Voltage Measurement... 11:05:58 Voltage Offset Correction: v_off_ini = -58.804 uV, v_off_fin = -68.501 uV 11:05:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.640 uVs 11:05:58 Integrated Voltage Measurement... 11:06:07 Voltage Offset Correction: v_off_ini = -47.139 uV, v_off_fin = -19.462 uV 11:06:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.756 uVs 11:06:07 Integrated Voltage Measurement... 11:06:16 Voltage Offset Correction: v_off_ini = -28.371 uV, v_off_fin = -38.832 uV 11:06:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -120.313 uVs 11:06:16 Integrated Voltage Measurement... 11:06:25 Voltage Offset Correction: v_off_ini = -40.601 uV, v_off_fin = -32.507 uV 11:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.926 uVs 11:06:25 Integrated Voltage Measurement... 11:06:34 Voltage Offset Correction: v_off_ini = -32.966 uV, v_off_fin = -32.246 uV 11:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.778 uVs 11:06:34 Integrated Voltage Measurement... 11:06:43 Voltage Offset Correction: v_off_ini = -47.466 uV, v_off_fin = -36.854 uV 11:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.352 uVs 11:06:45 I2X Average and RMS of Measurements VT = -102.961 +- 2.300 uVs I2X = 9.473 +- 0.211 uTm^2 11:06:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:53 Integrated Voltage Measurement... 11:07:02 Voltage Offset Correction: v_off_ini = -61.932 uV, v_off_fin = -57.976 uV 11:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.475 uVs 11:07:02 Integrated Voltage Measurement... 11:07:11 Voltage Offset Correction: v_off_ini = -56.603 uV, v_off_fin = -51.977 uV 11:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.454 uVs 11:07:11 Integrated Voltage Measurement... 11:07:20 Voltage Offset Correction: v_off_ini = -63.292 uV, v_off_fin = -55.108 uV 11:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.570 uVs 11:07:20 Integrated Voltage Measurement... 11:07:29 Voltage Offset Correction: v_off_ini = -55.592 uV, v_off_fin = -39.797 uV 11:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.496 uVs 11:07:29 Integrated Voltage Measurement... 11:07:38 Voltage Offset Correction: v_off_ini = -42.675 uV, v_off_fin = -49.860 uV 11:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.089 uVs 11:07:38 Integrated Voltage Measurement... 11:07:47 Voltage Offset Correction: v_off_ini = -35.912 uV, v_off_fin = -48.217 uV 11:07:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.489 uVs 11:07:50 I2Y Average and RMS of Measurements VT = -269.596 +- 8.511 uVs I2Y = -24.803 +- 0.783 uTm^2 11:08:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:08 Integrated Voltage Measurement... 11:08:17 Voltage Offset Correction: v_off_ini = -55.441 uV, v_off_fin = -52.391 uV 11:08:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -98.853 uVs 11:08:17 Integrated Voltage Measurement... 11:08:26 Voltage Offset Correction: v_off_ini = -52.394 uV, v_off_fin = -54.318 uV 11:08:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.227 uVs 11:08:26 Integrated Voltage Measurement... 11:08:35 Voltage Offset Correction: v_off_ini = -57.907 uV, v_off_fin = -63.525 uV 11:08:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.785 uVs 11:08:35 Integrated Voltage Measurement... 11:08:44 Voltage Offset Correction: v_off_ini = -43.510 uV, v_off_fin = -46.669 uV 11:08:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.136 uVs 11:08:44 Integrated Voltage Measurement... 11:08:53 Voltage Offset Correction: v_off_ini = -47.306 uV, v_off_fin = -49.852 uV 11:08:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.723 uVs 11:08:53 Integrated Voltage Measurement... 11:09:02 Voltage Offset Correction: v_off_ini = -45.107 uV, v_off_fin = -41.069 uV 11:09:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.546 uVs 11:09:06 I1X Average and RMS of Measurements VT = -100.378 +- 5.085 uVs I1X = 20.077 +- 1.018 uTm 11:09:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:13 Integrated Voltage Measurement... 11:09:22 Voltage Offset Correction: v_off_ini = -47.632 uV, v_off_fin = -54.508 uV 11:09:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.477 uVs 11:09:22 Integrated Voltage Measurement... 11:09:31 Voltage Offset Correction: v_off_ini = -29.606 uV, v_off_fin = -32.507 uV 11:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.584 uVs 11:09:31 Integrated Voltage Measurement... 11:09:40 Voltage Offset Correction: v_off_ini = -39.810 uV, v_off_fin = -53.832 uV 11:09:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.865 uVs 11:09:40 Integrated Voltage Measurement... 11:09:49 Voltage Offset Correction: v_off_ini = -31.794 uV, v_off_fin = -23.720 uV 11:09:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.379 uVs 11:09:50 Integrated Voltage Measurement... 11:09:58 Voltage Offset Correction: v_off_ini = -47.729 uV, v_off_fin = -55.831 uV 11:09:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -258.970 uVs 11:09:59 Integrated Voltage Measurement... 11:10:07 Voltage Offset Correction: v_off_ini = -29.866 uV, v_off_fin = -26.704 uV 11:10:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.493 uVs 11:10:12 I1Y Average and RMS of Measurements VT = -243.295 +- 6.857 uVs I1Y = -48.657 +- 1.372 uTm 11:10:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:19 Integrated Voltage Measurement... 11:10:28 Voltage Offset Correction: v_off_ini = -46.897 uV, v_off_fin = -46.379 uV 11:10:28 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.268 uVs 11:10:28 Integrated Voltage Measurement... 11:10:37 Voltage Offset Correction: v_off_ini = -29.417 uV, v_off_fin = -11.744 uV 11:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.927 uVs 11:10:38 Integrated Voltage Measurement... 11:10:47 Voltage Offset Correction: v_off_ini = -35.993 uV, v_off_fin = -48.490 uV 11:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.474 uVs 11:10:47 Integrated Voltage Measurement... 11:10:56 Voltage Offset Correction: v_off_ini = -32.526 uV, v_off_fin = -28.194 uV 11:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.430 uVs 11:10:56 Integrated Voltage Measurement... 11:11:05 Voltage Offset Correction: v_off_ini = -39.767 uV, v_off_fin = -52.897 uV 11:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.586 uVs 11:11:05 Integrated Voltage Measurement... 11:11:14 Voltage Offset Correction: v_off_ini = -24.512 uV, v_off_fin = -21.466 uV 11:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.024 uVs 11:11:16 I2X Average and RMS of Measurements VT = -95.118 +- 9.438 uVs I2X = 8.751 +- 0.868 uTm^2 11:11:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:24 Integrated Voltage Measurement... 11:11:33 Voltage Offset Correction: v_off_ini = -41.650 uV, v_off_fin = -51.477 uV 11:11:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.293 uVs 11:11:33 Integrated Voltage Measurement... 11:11:42 Voltage Offset Correction: v_off_ini = -41.537 uV, v_off_fin = -44.550 uV 11:11:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.261 uVs 11:11:42 Integrated Voltage Measurement... 11:11:51 Voltage Offset Correction: v_off_ini = -39.034 uV, v_off_fin = -55.765 uV 11:11:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.596 uVs 11:11:51 Integrated Voltage Measurement... 11:12:00 Voltage Offset Correction: v_off_ini = -50.594 uV, v_off_fin = -43.949 uV 11:12:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.817 uVs 11:12:00 Integrated Voltage Measurement... 11:12:09 Voltage Offset Correction: v_off_ini = -30.587 uV, v_off_fin = -31.660 uV 11:12:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.593 uVs 11:12:09 Integrated Voltage Measurement... 11:12:18 Voltage Offset Correction: v_off_ini = -46.662 uV, v_off_fin = -37.421 uV 11:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.425 uVs 11:12:21 I2Y Average and RMS of Measurements VT = -267.164 +- 2.790 uVs I2Y = -24.579 +- 0.257 uTm^2 11:12:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:39 Integrated Voltage Measurement... 11:12:48 Voltage Offset Correction: v_off_ini = -20.945 uV, v_off_fin = -43.035 uV 11:12:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -106.243 uVs 11:12:48 Integrated Voltage Measurement... 11:12:57 Voltage Offset Correction: v_off_ini = -45.540 uV, v_off_fin = -37.098 uV 11:12:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.431 uVs 11:12:57 Integrated Voltage Measurement... 11:13:06 Voltage Offset Correction: v_off_ini = -44.039 uV, v_off_fin = -44.347 uV 11:13:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.210 uVs 11:13:06 Integrated Voltage Measurement... 11:13:15 Voltage Offset Correction: v_off_ini = -44.243 uV, v_off_fin = -45.928 uV 11:13:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.060 uVs 11:13:15 Integrated Voltage Measurement... 11:13:24 Voltage Offset Correction: v_off_ini = -45.146 uV, v_off_fin = -37.502 uV 11:13:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.984 uVs 11:13:24 Integrated Voltage Measurement... 11:13:33 Voltage Offset Correction: v_off_ini = -34.001 uV, v_off_fin = -30.671 uV 11:13:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.335 uVs 11:13:37 I1X Average and RMS of Measurements VT = -92.377 +- 5.801 uVs I1X = 18.477 +- 1.162 uTm 11:13:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:44 Integrated Voltage Measurement... 11:13:53 Voltage Offset Correction: v_off_ini = -22.161 uV, v_off_fin = -43.553 uV 11:13:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.440 uVs 11:13:53 Integrated Voltage Measurement... 11:14:02 Voltage Offset Correction: v_off_ini = -34.878 uV, v_off_fin = -32.062 uV 11:14:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 241.530 uVs 11:14:02 Integrated Voltage Measurement... 11:14:11 Voltage Offset Correction: v_off_ini = -54.047 uV, v_off_fin = -65.474 uV 11:14:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -239.122 uVs 11:14:11 Integrated Voltage Measurement... 11:14:20 Voltage Offset Correction: v_off_ini = -39.386 uV, v_off_fin = -20.228 uV 11:14:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 257.166 uVs 11:14:20 Integrated Voltage Measurement... 11:14:29 Voltage Offset Correction: v_off_ini = -42.321 uV, v_off_fin = -56.086 uV 11:14:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.776 uVs 11:14:29 Integrated Voltage Measurement... 11:14:38 Voltage Offset Correction: v_off_ini = -38.499 uV, v_off_fin = -18.156 uV 11:14:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.506 uVs 11:14:42 I1Y Average and RMS of Measurements VT = -243.590 +- 3.676 uVs I1Y = -48.713 +- 0.735 uTm 11:14:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:14:50 Integrated Voltage Measurement... 11:14:59 Voltage Offset Correction: v_off_ini = -37.753 uV, v_off_fin = -40.558 uV 11:14:59 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -106.788 uVs 11:14:59 Integrated Voltage Measurement... 11:15:08 Voltage Offset Correction: v_off_ini = -33.126 uV, v_off_fin = -22.216 uV 11:15:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.445 uVs 11:15:08 Integrated Voltage Measurement... 11:15:17 Voltage Offset Correction: v_off_ini = -35.080 uV, v_off_fin = -49.982 uV 11:15:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.333 uVs 11:15:17 Integrated Voltage Measurement... 11:15:26 Voltage Offset Correction: v_off_ini = -40.878 uV, v_off_fin = -19.396 uV 11:15:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.666 uVs 11:15:26 Integrated Voltage Measurement... 11:15:35 Voltage Offset Correction: v_off_ini = -26.985 uV, v_off_fin = -41.662 uV 11:15:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.311 uVs 11:15:35 Integrated Voltage Measurement... 11:15:44 Voltage Offset Correction: v_off_ini = -31.054 uV, v_off_fin = -31.218 uV 11:15:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.935 uVs 11:15:47 I2X Average and RMS of Measurements VT = -108.746 +- 10.322 uVs I2X = 10.004 +- 0.949 uTm^2 11:15:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:55 Integrated Voltage Measurement... 11:16:04 Voltage Offset Correction: v_off_ini = -47.155 uV, v_off_fin = -40.776 uV 11:16:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.427 uVs 11:16:04 Integrated Voltage Measurement... 11:16:13 Voltage Offset Correction: v_off_ini = -34.369 uV, v_off_fin = -25.627 uV 11:16:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.999 uVs 11:16:13 Integrated Voltage Measurement... 11:16:22 Voltage Offset Correction: v_off_ini = -30.622 uV, v_off_fin = -35.291 uV 11:16:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.185 uVs 11:16:22 Integrated Voltage Measurement... 11:16:31 Voltage Offset Correction: v_off_ini = -35.263 uV, v_off_fin = -26.858 uV 11:16:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.257 uVs 11:16:31 Integrated Voltage Measurement... 11:16:40 Voltage Offset Correction: v_off_ini = -32.511 uV, v_off_fin = -35.190 uV 11:16:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.194 uVs 11:16:40 Integrated Voltage Measurement... 11:16:49 Voltage Offset Correction: v_off_ini = -30.323 uV, v_off_fin = -31.648 uV 11:16:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.111 uVs 11:16:51 I2Y Average and RMS of Measurements VT = -273.862 +- 3.088 uVs I2Y = -25.195 +- 0.284 uTm^2 11:17:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:09 Integrated Voltage Measurement... 11:17:18 Voltage Offset Correction: v_off_ini = -18.762 uV, v_off_fin = -21.868 uV 11:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.260 uVs 11:17:19 Integrated Voltage Measurement... 11:17:27 Voltage Offset Correction: v_off_ini = -33.427 uV, v_off_fin = -15.601 uV 11:17:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.703 uVs 11:17:28 Integrated Voltage Measurement... 11:17:37 Voltage Offset Correction: v_off_ini = -29.761 uV, v_off_fin = -35.627 uV 11:17:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.702 uVs 11:17:37 Integrated Voltage Measurement... 11:17:46 Voltage Offset Correction: v_off_ini = -38.353 uV, v_off_fin = -32.057 uV 11:17:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.360 uVs 11:17:46 Integrated Voltage Measurement... 11:17:55 Voltage Offset Correction: v_off_ini = -32.407 uV, v_off_fin = -48.827 uV 11:17:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.656 uVs 11:17:55 Integrated Voltage Measurement... 11:18:04 Voltage Offset Correction: v_off_ini = -47.775 uV, v_off_fin = -38.921 uV 11:18:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.057 uVs 11:18:08 I1X Average and RMS of Measurements VT = -106.290 +- 7.529 uVs I1X = 21.258 +- 1.506 uTm 11:18:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:15 Integrated Voltage Measurement... 11:18:24 Voltage Offset Correction: v_off_ini = -36.253 uV, v_off_fin = -49.368 uV 11:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -235.619 uVs 11:18:24 Integrated Voltage Measurement... 11:18:33 Voltage Offset Correction: v_off_ini = -34.388 uV, v_off_fin = 3.217 uV 11:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.871 uVs 11:18:33 Integrated Voltage Measurement... 11:18:42 Voltage Offset Correction: v_off_ini = -12.355 uV, v_off_fin = -22.634 uV 11:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.961 uVs 11:18:42 Integrated Voltage Measurement... 11:18:51 Voltage Offset Correction: v_off_ini = -5.809 uV, v_off_fin = 6.195 uV 11:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.294 uVs 11:18:51 Integrated Voltage Measurement... 11:19:00 Voltage Offset Correction: v_off_ini = -9.583 uV, v_off_fin = -23.489 uV 11:19:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -246.417 uVs 11:19:00 Integrated Voltage Measurement... 11:19:09 Voltage Offset Correction: v_off_ini = -13.101 uV, v_off_fin = 15.645 uV 11:19:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.351 uVs 11:19:13 I1Y Average and RMS of Measurements VT = -240.752 +- 4.519 uVs I1Y = -48.148 +- 0.902 uTm 11:19:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:20 Integrated Voltage Measurement... 11:19:29 Voltage Offset Correction: v_off_ini = -12.131 uV, v_off_fin = -19.350 uV 11:19:30 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -106.970 uVs 11:19:30 Integrated Voltage Measurement... 11:19:39 Voltage Offset Correction: v_off_ini = -35.792 uV, v_off_fin = -10.808 uV 11:19:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.275 uVs 11:19:39 Integrated Voltage Measurement... 11:19:48 Voltage Offset Correction: v_off_ini = -29.546 uV, v_off_fin = -38.201 uV 11:19:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -94.714 uVs 11:19:48 Integrated Voltage Measurement... 11:19:57 Voltage Offset Correction: v_off_ini = -27.964 uV, v_off_fin = -3.201 uV 11:19:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.187 uVs 11:19:57 Integrated Voltage Measurement... 11:20:06 Voltage Offset Correction: v_off_ini = -18.217 uV, v_off_fin = -19.371 uV 11:20:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.624 uVs 11:20:06 Integrated Voltage Measurement... 11:20:15 Voltage Offset Correction: v_off_ini = -29.598 uV, v_off_fin = -16.870 uV 11:20:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.388 uVs 11:20:17 I2X Average and RMS of Measurements VT = -105.193 +- 2.103 uVs I2X = 9.678 +- 0.193 uTm^2 11:20:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:25 Integrated Voltage Measurement... 11:20:34 Voltage Offset Correction: v_off_ini = -48.240 uV, v_off_fin = -30.320 uV 11:20:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.094 uVs 11:20:34 Integrated Voltage Measurement... 11:20:43 Voltage Offset Correction: v_off_ini = -30.714 uV, v_off_fin = -19.241 uV 11:20:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 256.136 uVs 11:20:43 Integrated Voltage Measurement... 11:20:52 Voltage Offset Correction: v_off_ini = -35.127 uV, v_off_fin = -31.560 uV 11:20:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.867 uVs 11:20:52 Integrated Voltage Measurement... 11:21:01 Voltage Offset Correction: v_off_ini = -23.287 uV, v_off_fin = -24.322 uV 11:21:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.617 uVs 11:21:01 Integrated Voltage Measurement... 11:21:10 Voltage Offset Correction: v_off_ini = -26.203 uV, v_off_fin = -18.603 uV 11:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.470 uVs 11:21:10 Integrated Voltage Measurement... 11:21:19 Voltage Offset Correction: v_off_ini = -13.576 uV, v_off_fin = -9.853 uV 11:21:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 252.146 uVs 11:21:22 I2Y Average and RMS of Measurements VT = -256.722 +- 6.930 uVs I2Y = -23.619 +- 0.638 uTm^2 11:21:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:40 Integrated Voltage Measurement... 11:21:49 Voltage Offset Correction: v_off_ini = -13.960 uV, v_off_fin = -17.076 uV 11:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.575 uVs 11:21:49 Integrated Voltage Measurement... 11:21:58 Voltage Offset Correction: v_off_ini = -17.933 uV, v_off_fin = -13.953 uV 11:21:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.299 uVs 11:21:58 Integrated Voltage Measurement... 11:22:07 Voltage Offset Correction: v_off_ini = 4.121 uV, v_off_fin = -4.644 uV 11:22:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.225 uVs 11:22:07 Integrated Voltage Measurement... 11:22:16 Voltage Offset Correction: v_off_ini = -12.473 uV, v_off_fin = -15.212 uV 11:22:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.787 uVs 11:22:16 Integrated Voltage Measurement... 11:22:25 Voltage Offset Correction: v_off_ini = -12.510 uV, v_off_fin = -17.349 uV 11:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.030 uVs 11:22:25 Integrated Voltage Measurement... 11:22:34 Voltage Offset Correction: v_off_ini = -23.732 uV, v_off_fin = -16.681 uV 11:22:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.288 uVs 11:22:38 I1X Average and RMS of Measurements VT = -99.367 +- 7.527 uVs I1X = 19.874 +- 1.506 uTm 11:22:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:45 Integrated Voltage Measurement... 11:22:54 Voltage Offset Correction: v_off_ini = -18.164 uV, v_off_fin = -20.669 uV 11:22:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.245 uVs 11:22:54 Integrated Voltage Measurement... 11:23:03 Voltage Offset Correction: v_off_ini = -7.903 uV, v_off_fin = 8.181 uV 11:23:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.316 uVs 11:23:03 Integrated Voltage Measurement... 11:23:12 Voltage Offset Correction: v_off_ini = -13.341 uV, v_off_fin = -24.656 uV 11:23:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.990 uVs 11:23:12 Integrated Voltage Measurement... 11:23:21 Voltage Offset Correction: v_off_ini = -20.589 uV, v_off_fin = -20.087 uV 11:23:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.939 uVs 11:23:21 Integrated Voltage Measurement... 11:23:30 Voltage Offset Correction: v_off_ini = -12.061 uV, v_off_fin = -23.228 uV 11:23:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -250.078 uVs 11:23:30 Integrated Voltage Measurement... 11:23:39 Voltage Offset Correction: v_off_ini = -20.918 uV, v_off_fin = -10.486 uV 11:23:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.469 uVs 11:23:43 I1Y Average and RMS of Measurements VT = -241.173 +- 3.602 uVs I1Y = -48.230 +- 0.720 uTm 11:23:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:51 Integrated Voltage Measurement... 11:24:00 Voltage Offset Correction: v_off_ini = -9.307 uV, v_off_fin = -34.513 uV 11:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.419 uVs 11:24:00 Integrated Voltage Measurement... 11:24:09 Voltage Offset Correction: v_off_ini = -33.317 uV, v_off_fin = -4.108 uV 11:24:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.966 uVs 11:24:09 Integrated Voltage Measurement... 11:24:18 Voltage Offset Correction: v_off_ini = -21.368 uV, v_off_fin = -22.792 uV 11:24:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.978 uVs 11:24:18 Integrated Voltage Measurement... 11:24:27 Voltage Offset Correction: v_off_ini = -25.775 uV, v_off_fin = -14.296 uV 11:24:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.956 uVs 11:24:27 Integrated Voltage Measurement... 11:24:36 Voltage Offset Correction: v_off_ini = -33.252 uV, v_off_fin = -38.596 uV 11:24:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.539 uVs 11:24:36 Integrated Voltage Measurement... 11:24:45 Voltage Offset Correction: v_off_ini = -43.955 uV, v_off_fin = -15.521 uV 11:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.804 uVs 11:24:47 I2X Average and RMS of Measurements VT = -102.777 +- 8.321 uVs I2X = 9.456 +- 0.766 uTm^2 11:24:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:55 Integrated Voltage Measurement... 11:25:04 Voltage Offset Correction: v_off_ini = -17.734 uV, v_off_fin = -22.184 uV 11:25:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.501 uVs 11:25:04 Integrated Voltage Measurement... 11:25:13 Voltage Offset Correction: v_off_ini = -14.410 uV, v_off_fin = -4.924 uV 11:25:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.022 uVs 11:25:13 Integrated Voltage Measurement... 11:25:22 Voltage Offset Correction: v_off_ini = -24.093 uV, v_off_fin = -31.126 uV 11:25:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.932 uVs 11:25:22 Integrated Voltage Measurement... 11:25:31 Voltage Offset Correction: v_off_ini = -11.034 uV, v_off_fin = -19.263 uV 11:25:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.365 uVs 11:25:31 Integrated Voltage Measurement... 11:25:40 Voltage Offset Correction: v_off_ini = -13.836 uV, v_off_fin = -13.998 uV 11:25:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.066 uVs 11:25:40 Integrated Voltage Measurement... 11:25:49 Voltage Offset Correction: v_off_ini = -17.736 uV, v_off_fin = -16.913 uV 11:25:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.609 uVs 11:25:52 I2Y Average and RMS of Measurements VT = -258.582 +- 3.013 uVs I2Y = -23.790 +- 0.277 uTm^2 11:26:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:10 Integrated Voltage Measurement... 11:26:19 Voltage Offset Correction: v_off_ini = 1.609 uV, v_off_fin = -4.953 uV 11:26:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -109.657 uVs 11:26:19 Integrated Voltage Measurement... 11:26:28 Voltage Offset Correction: v_off_ini = -5.307 uV, v_off_fin = 4.473 uV 11:26:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.750 uVs 11:26:28 Integrated Voltage Measurement... 11:26:37 Voltage Offset Correction: v_off_ini = 1.839 uV, v_off_fin = -3.699 uV 11:26:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.322 uVs 11:26:37 Integrated Voltage Measurement... 11:26:46 Voltage Offset Correction: v_off_ini = 6.589 uV, v_off_fin = -4.056 uV 11:26:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.801 uVs 11:26:46 Integrated Voltage Measurement... 11:26:55 Voltage Offset Correction: v_off_ini = 1.635 uV, v_off_fin = -3.546 uV 11:26:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.154 uVs 11:26:55 Integrated Voltage Measurement... 11:27:04 Voltage Offset Correction: v_off_ini = 5.543 uV, v_off_fin = 2.296 uV 11:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.003 uVs 11:27:08 I1X Average and RMS of Measurements VT = -101.781 +- 4.899 uVs I1X = 20.357 +- 0.981 uTm 11:27:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:15 Integrated Voltage Measurement... 11:27:24 Voltage Offset Correction: v_off_ini = -8.047 uV, v_off_fin = -6.357 uV 11:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.452 uVs 11:27:24 Integrated Voltage Measurement... 11:27:33 Voltage Offset Correction: v_off_ini = -0.937 uV, v_off_fin = 24.045 uV 11:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 235.866 uVs 11:27:33 Integrated Voltage Measurement... 11:27:42 Voltage Offset Correction: v_off_ini = -4.455 uV, v_off_fin = -6.965 uV 11:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -236.275 uVs 11:27:42 Integrated Voltage Measurement... 11:27:51 Voltage Offset Correction: v_off_ini = 9.021 uV, v_off_fin = 24.634 uV 11:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.339 uVs 11:27:51 Integrated Voltage Measurement... 11:28:00 Voltage Offset Correction: v_off_ini = 3.238 uV, v_off_fin = -0.625 uV 11:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -248.544 uVs 11:28:00 Integrated Voltage Measurement... 11:28:09 Voltage Offset Correction: v_off_ini = 12.830 uV, v_off_fin = 29.641 uV 11:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 250.513 uVs 11:28:13 I1Y Average and RMS of Measurements VT = -237.831 +- 8.272 uVs I1Y = -47.558 +- 1.653 uTm 11:28:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:21 Integrated Voltage Measurement... 11:28:30 Voltage Offset Correction: v_off_ini = 16.375 uV, v_off_fin = 21.273 uV 11:28:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.757 uVs 11:28:30 Integrated Voltage Measurement... 11:28:39 Voltage Offset Correction: v_off_ini = 15.692 uV, v_off_fin = 25.973 uV 11:28:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.016 uVs 11:28:39 Integrated Voltage Measurement... 11:28:48 Voltage Offset Correction: v_off_ini = 19.442 uV, v_off_fin = 10.646 uV 11:28:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.226 uVs 11:28:48 Integrated Voltage Measurement... 11:28:57 Voltage Offset Correction: v_off_ini = 36.309 uV, v_off_fin = 38.026 uV 11:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.464 uVs 11:28:57 Integrated Voltage Measurement... 11:29:06 Voltage Offset Correction: v_off_ini = 37.093 uV, v_off_fin = 25.755 uV 11:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.943 uVs 11:29:06 Integrated Voltage Measurement... 11:29:15 Voltage Offset Correction: v_off_ini = 29.510 uV, v_off_fin = 41.099 uV 11:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.497 uVs 11:29:17 I2X Average and RMS of Measurements VT = -107.150 +- 10.684 uVs I2X = 9.858 +- 0.983 uTm^2 11:29:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:25 Integrated Voltage Measurement... 11:29:34 Voltage Offset Correction: v_off_ini = 44.109 uV, v_off_fin = 41.805 uV 11:29:34 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -252.261 uVs 11:29:34 Integrated Voltage Measurement... 11:29:43 Voltage Offset Correction: v_off_ini = 32.874 uV, v_off_fin = 38.302 uV 11:29:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.840 uVs 11:29:43 Integrated Voltage Measurement... 11:29:52 Voltage Offset Correction: v_off_ini = 30.714 uV, v_off_fin = 25.428 uV 11:29:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -259.378 uVs 11:29:52 Integrated Voltage Measurement... 11:30:01 Voltage Offset Correction: v_off_ini = 31.809 uV, v_off_fin = 22.707 uV 11:30:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.577 uVs 11:30:01 Integrated Voltage Measurement... 11:30:10 Voltage Offset Correction: v_off_ini = 26.693 uV, v_off_fin = 30.604 uV 11:30:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.324 uVs 11:30:10 Integrated Voltage Measurement... 11:30:19 Voltage Offset Correction: v_off_ini = 31.482 uV, v_off_fin = 23.181 uV 11:30:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.709 uVs 11:30:22 I2Y Average and RMS of Measurements VT = -255.681 +- 2.301 uVs I2Y = -23.523 +- 0.212 uTm^2 11:30:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:40 Integrated Voltage Measurement... 11:30:49 Voltage Offset Correction: v_off_ini = 44.449 uV, v_off_fin = 43.662 uV 11:30:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.705 uVs 11:30:49 Integrated Voltage Measurement... 11:30:58 Voltage Offset Correction: v_off_ini = 47.072 uV, v_off_fin = 41.482 uV 11:30:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.693 uVs 11:30:58 Integrated Voltage Measurement... 11:31:07 Voltage Offset Correction: v_off_ini = 45.720 uV, v_off_fin = 36.644 uV 11:31:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.838 uVs 11:31:07 Integrated Voltage Measurement... 11:31:16 Voltage Offset Correction: v_off_ini = 31.424 uV, v_off_fin = 45.721 uV 11:31:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.387 uVs 11:31:16 Integrated Voltage Measurement... 11:31:25 Voltage Offset Correction: v_off_ini = 28.882 uV, v_off_fin = 30.747 uV 11:31:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.361 uVs 11:31:25 Integrated Voltage Measurement... 11:31:34 Voltage Offset Correction: v_off_ini = 40.509 uV, v_off_fin = 40.831 uV 11:31:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.429 uVs 11:31:38 I1X Average and RMS of Measurements VT = -107.736 +- 6.630 uVs I1X = 21.547 +- 1.326 uTm 11:31:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:45 Integrated Voltage Measurement... 11:31:54 Voltage Offset Correction: v_off_ini = 43.964 uV, v_off_fin = 34.858 uV 11:31:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.262 uVs 11:31:54 Integrated Voltage Measurement... 11:32:03 Voltage Offset Correction: v_off_ini = 45.537 uV, v_off_fin = 60.304 uV 11:32:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.627 uVs 11:32:03 Integrated Voltage Measurement... 11:32:12 Voltage Offset Correction: v_off_ini = 44.368 uV, v_off_fin = 17.229 uV 11:32:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -244.764 uVs 11:32:12 Integrated Voltage Measurement... 11:32:21 Voltage Offset Correction: v_off_ini = 35.586 uV, v_off_fin = 57.518 uV 11:32:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.844 uVs 11:32:21 Integrated Voltage Measurement... 11:32:30 Voltage Offset Correction: v_off_ini = 45.838 uV, v_off_fin = 25.611 uV 11:32:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -250.646 uVs 11:32:30 Integrated Voltage Measurement... 11:32:39 Voltage Offset Correction: v_off_ini = 32.242 uV, v_off_fin = 46.919 uV 11:32:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.525 uVs 11:32:44 I1Y Average and RMS of Measurements VT = -237.111 +- 6.490 uVs I1Y = -47.417 +- 1.298 uTm 11:32:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:51 Integrated Voltage Measurement... 11:33:00 Voltage Offset Correction: v_off_ini = 39.768 uV, v_off_fin = 36.899 uV 11:33:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -103.369 uVs 11:33:00 Integrated Voltage Measurement... 11:33:09 Voltage Offset Correction: v_off_ini = 56.870 uV, v_off_fin = 65.530 uV 11:33:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.906 uVs 11:33:09 Integrated Voltage Measurement... 11:33:18 Voltage Offset Correction: v_off_ini = 42.029 uV, v_off_fin = 40.948 uV 11:33:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.587 uVs 11:33:18 Integrated Voltage Measurement... 11:33:27 Voltage Offset Correction: v_off_ini = 45.567 uV, v_off_fin = 44.664 uV 11:33:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.836 uVs 11:33:27 Integrated Voltage Measurement... 11:33:36 Voltage Offset Correction: v_off_ini = 47.214 uV, v_off_fin = 30.608 uV 11:33:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.117 uVs 11:33:37 Integrated Voltage Measurement... 11:33:46 Voltage Offset Correction: v_off_ini = 48.004 uV, v_off_fin = 51.744 uV 11:33:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.856 uVs 11:33:48 I2X Average and RMS of Measurements VT = -101.945 +- 2.625 uVs I2X = 9.379 +- 0.242 uTm^2 11:33:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:56 Integrated Voltage Measurement... 11:34:05 Voltage Offset Correction: v_off_ini = 59.434 uV, v_off_fin = 61.252 uV 11:34:05 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -268.828 uVs 11:34:05 Integrated Voltage Measurement... 11:34:14 Voltage Offset Correction: v_off_ini = 39.396 uV, v_off_fin = 55.898 uV 11:34:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.585 uVs 11:34:14 Integrated Voltage Measurement... 11:34:23 Voltage Offset Correction: v_off_ini = 47.327 uV, v_off_fin = 54.271 uV 11:34:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.981 uVs 11:34:23 Integrated Voltage Measurement... 11:34:32 Voltage Offset Correction: v_off_ini = 59.513 uV, v_off_fin = 61.870 uV 11:34:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.878 uVs 11:34:32 Integrated Voltage Measurement... 11:34:41 Voltage Offset Correction: v_off_ini = 69.814 uV, v_off_fin = 65.592 uV 11:34:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.898 uVs 11:34:41 Integrated Voltage Measurement... 11:34:50 Voltage Offset Correction: v_off_ini = 65.387 uV, v_off_fin = 58.851 uV 11:34:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.570 uVs 11:34:53 I2Y Average and RMS of Measurements VT = -248.790 +- 3.841 uVs I2Y = -22.888 +- 0.353 uTm^2 11:34:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm