SLAC Magnetic Measurements Date: 10-21-2025 Time: 08:30:09 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16347 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 08:30:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:30:19 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:30:21 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:30:22 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:30:24 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:30:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:30:44 Integrated Voltage Measurement... 08:30:53 Voltage Offset Correction: v_off_ini = -473.823 uV, v_off_fin = -482.718 uV 08:30:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.699 uVs 08:30:53 Integrated Voltage Measurement... 08:31:02 Voltage Offset Correction: v_off_ini = -483.538 uV, v_off_fin = -476.672 uV 08:31:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.088 uVs 08:31:02 Integrated Voltage Measurement... 08:31:11 Voltage Offset Correction: v_off_ini = -483.890 uV, v_off_fin = -480.081 uV 08:31:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -111.305 uVs 08:31:11 Integrated Voltage Measurement... 08:31:20 Voltage Offset Correction: v_off_ini = -467.913 uV, v_off_fin = -460.547 uV 08:31:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 113.283 uVs 08:31:20 Integrated Voltage Measurement... 08:31:29 Voltage Offset Correction: v_off_ini = -473.005 uV, v_off_fin = -476.331 uV 08:31:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.192 uVs 08:31:29 Integrated Voltage Measurement... 08:31:38 Voltage Offset Correction: v_off_ini = -451.325 uV, v_off_fin = -452.739 uV 08:31:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.379 uVs 08:31:43 I1X Average and RMS of Measurements VT = -107.491 +- 4.887 uVs I1X = 21.500 +- 0.979 uTm 08:31:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:31:49 Integrated Voltage Measurement... 08:31:58 Voltage Offset Correction: v_off_ini = -470.160 uV, v_off_fin = -475.750 uV 08:31:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -89.598 uVs 08:31:58 Integrated Voltage Measurement... 08:32:07 Voltage Offset Correction: v_off_ini = -465.258 uV, v_off_fin = -457.355 uV 08:32:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 102.463 uVs 08:32:07 Integrated Voltage Measurement... 08:32:16 Voltage Offset Correction: v_off_ini = -471.803 uV, v_off_fin = -477.913 uV 08:32:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -83.353 uVs 08:32:16 Integrated Voltage Measurement... 08:32:25 Voltage Offset Correction: v_off_ini = -467.897 uV, v_off_fin = -450.305 uV 08:32:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 106.557 uVs 08:32:25 Integrated Voltage Measurement... 08:32:34 Voltage Offset Correction: v_off_ini = -472.585 uV, v_off_fin = -470.617 uV 08:32:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -85.910 uVs 08:32:34 Integrated Voltage Measurement... 08:32:43 Voltage Offset Correction: v_off_ini = -443.674 uV, v_off_fin = -441.951 uV 08:32:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 80.571 uVs 08:32:48 I1Y Average and RMS of Measurements VT = -91.409 +- 5.793 uVs I1Y = -18.280 +- 1.158 uTm 08:32:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:32:55 Integrated Voltage Measurement... 08:33:04 Voltage Offset Correction: v_off_ini = -451.392 uV, v_off_fin = -461.279 uV 08:33:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -154.267 uVs 08:33:04 Integrated Voltage Measurement... 08:33:13 Voltage Offset Correction: v_off_ini = -457.285 uV, v_off_fin = -431.754 uV 08:33:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 143.613 uVs 08:33:13 Integrated Voltage Measurement... 08:33:22 Voltage Offset Correction: v_off_ini = -442.364 uV, v_off_fin = -446.869 uV 08:33:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.794 uVs 08:33:23 Integrated Voltage Measurement... 08:33:32 Voltage Offset Correction: v_off_ini = -429.177 uV, v_off_fin = -411.733 uV 08:33:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.651 uVs 08:33:32 Integrated Voltage Measurement... 08:33:41 Voltage Offset Correction: v_off_ini = -435.233 uV, v_off_fin = -441.899 uV 08:33:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.030 uVs 08:33:41 Integrated Voltage Measurement... 08:33:50 Voltage Offset Correction: v_off_ini = -429.741 uV, v_off_fin = -421.691 uV 08:33:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.659 uVs 08:33:52 I2X Average and RMS of Measurements VT = -148.502 +- 6.589 uVs I2X = 13.662 +- 0.606 uTm^2 08:33:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:34:00 Integrated Voltage Measurement... 08:34:09 Voltage Offset Correction: v_off_ini = -420.832 uV, v_off_fin = -417.700 uV 08:34:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.950 uVs 08:34:09 Integrated Voltage Measurement... 08:34:18 Voltage Offset Correction: v_off_ini = -416.455 uV, v_off_fin = -417.037 uV 08:34:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.207 uVs 08:34:18 Integrated Voltage Measurement... 08:34:27 Voltage Offset Correction: v_off_ini = -410.041 uV, v_off_fin = -428.168 uV 08:34:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -130.187 uVs 08:34:27 Integrated Voltage Measurement... 08:34:36 Voltage Offset Correction: v_off_ini = -416.068 uV, v_off_fin = -416.850 uV 08:34:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 116.159 uVs 08:34:36 Integrated Voltage Measurement... 08:34:45 Voltage Offset Correction: v_off_ini = -414.913 uV, v_off_fin = -417.396 uV 08:34:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.002 uVs 08:34:45 Integrated Voltage Measurement... 08:34:54 Voltage Offset Correction: v_off_ini = -409.977 uV, v_off_fin = -415.592 uV 08:34:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 135.614 uVs 08:34:56 I2Y Average and RMS of Measurements VT = -139.353 +- 13.439 uVs I2Y = -12.821 +- 1.236 uTm^2 08:35:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:35:11 Integrated Voltage Measurement... 08:35:20 Voltage Offset Correction: v_off_ini = -447.814 uV, v_off_fin = -439.969 uV 08:35:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.950 uVs 08:35:20 Integrated Voltage Measurement... 08:35:29 Voltage Offset Correction: v_off_ini = -424.374 uV, v_off_fin = -420.297 uV 08:35:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 103.527 uVs 08:35:29 Integrated Voltage Measurement... 08:35:38 Voltage Offset Correction: v_off_ini = -427.876 uV, v_off_fin = -437.897 uV 08:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.900 uVs 08:35:38 Integrated Voltage Measurement... 08:35:47 Voltage Offset Correction: v_off_ini = -425.255 uV, v_off_fin = -422.061 uV 08:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.049 uVs 08:35:47 Integrated Voltage Measurement... 08:35:56 Voltage Offset Correction: v_off_ini = -419.183 uV, v_off_fin = -413.267 uV 08:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.270 uVs 08:35:56 Integrated Voltage Measurement... 08:36:05 Voltage Offset Correction: v_off_ini = -416.534 uV, v_off_fin = -414.641 uV 08:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.810 uVs 08:36:10 I1X Average and RMS of Measurements VT = -116.418 +- 6.142 uVs I1X = 23.285 +- 1.227 uTm 08:36:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:36:16 Integrated Voltage Measurement... 08:36:25 Voltage Offset Correction: v_off_ini = -403.613 uV, v_off_fin = -412.510 uV 08:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -107.802 uVs 08:36:25 Integrated Voltage Measurement... 08:36:34 Voltage Offset Correction: v_off_ini = -418.316 uV, v_off_fin = -401.580 uV 08:36:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 126.772 uVs 08:36:34 Integrated Voltage Measurement... 08:36:43 Voltage Offset Correction: v_off_ini = -393.553 uV, v_off_fin = -403.645 uV 08:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -102.594 uVs 08:36:43 Integrated Voltage Measurement... 08:36:52 Voltage Offset Correction: v_off_ini = -378.015 uV, v_off_fin = -375.439 uV 08:36:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 110.921 uVs 08:36:53 Integrated Voltage Measurement... 08:37:01 Voltage Offset Correction: v_off_ini = -394.096 uV, v_off_fin = -397.731 uV 08:37:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -117.298 uVs 08:37:02 Integrated Voltage Measurement... 08:37:10 Voltage Offset Correction: v_off_ini = -396.179 uV, v_off_fin = -375.438 uV 08:37:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 124.776 uVs 08:37:15 I1Y Average and RMS of Measurements VT = -115.027 +- 6.044 uVs I1Y = -23.004 +- 1.208 uTm 08:37:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:37:22 Integrated Voltage Measurement... 08:37:31 Voltage Offset Correction: v_off_ini = -380.043 uV, v_off_fin = -397.720 uV 08:37:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -147.543 uVs 08:37:31 Integrated Voltage Measurement... 08:37:40 Voltage Offset Correction: v_off_ini = -387.370 uV, v_off_fin = -368.222 uV 08:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.141 uVs 08:37:41 Integrated Voltage Measurement... 08:37:50 Voltage Offset Correction: v_off_ini = -378.701 uV, v_off_fin = -392.925 uV 08:37:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.549 uVs 08:37:50 Integrated Voltage Measurement... 08:37:59 Voltage Offset Correction: v_off_ini = -385.422 uV, v_off_fin = -377.710 uV 08:37:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 146.028 uVs 08:37:59 Integrated Voltage Measurement... 08:38:08 Voltage Offset Correction: v_off_ini = -393.019 uV, v_off_fin = -397.373 uV 08:38:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.676 uVs 08:38:08 Integrated Voltage Measurement... 08:38:17 Voltage Offset Correction: v_off_ini = -383.216 uV, v_off_fin = -377.591 uV 08:38:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.088 uVs 08:38:19 I2X Average and RMS of Measurements VT = -146.838 +- 2.821 uVs I2X = 13.509 +- 0.260 uTm^2 08:38:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:38:27 Integrated Voltage Measurement... 08:38:36 Voltage Offset Correction: v_off_ini = -399.128 uV, v_off_fin = -392.154 uV 08:38:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.102 uVs 08:38:36 Integrated Voltage Measurement... 08:38:45 Voltage Offset Correction: v_off_ini = -398.752 uV, v_off_fin = -383.087 uV 08:38:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.171 uVs 08:38:45 Integrated Voltage Measurement... 08:38:54 Voltage Offset Correction: v_off_ini = -384.890 uV, v_off_fin = -386.154 uV 08:38:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -162.567 uVs 08:38:54 Integrated Voltage Measurement... 08:39:03 Voltage Offset Correction: v_off_ini = -393.992 uV, v_off_fin = -372.341 uV 08:39:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.542 uVs 08:39:03 Integrated Voltage Measurement... 08:39:12 Voltage Offset Correction: v_off_ini = -375.706 uV, v_off_fin = -377.600 uV 08:39:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -148.932 uVs 08:39:12 Integrated Voltage Measurement... 08:39:21 Voltage Offset Correction: v_off_ini = -376.271 uV, v_off_fin = -376.270 uV 08:39:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 145.333 uVs 08:39:23 I2Y Average and RMS of Measurements VT = -162.108 +- 10.664 uVs I2Y = -14.914 +- 0.981 uTm^2 08:39:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:39:38 Integrated Voltage Measurement... 08:39:47 Voltage Offset Correction: v_off_ini = -369.197 uV, v_off_fin = -381.073 uV 08:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.717 uVs 08:39:47 Integrated Voltage Measurement... 08:39:56 Voltage Offset Correction: v_off_ini = -365.920 uV, v_off_fin = -362.849 uV 08:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.575 uVs 08:39:57 Integrated Voltage Measurement... 08:40:06 Voltage Offset Correction: v_off_ini = -373.956 uV, v_off_fin = -393.462 uV 08:40:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.313 uVs 08:40:06 Integrated Voltage Measurement... 08:40:15 Voltage Offset Correction: v_off_ini = -377.942 uV, v_off_fin = -370.086 uV 08:40:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.188 uVs 08:40:15 Integrated Voltage Measurement... 08:40:24 Voltage Offset Correction: v_off_ini = -364.269 uV, v_off_fin = -367.740 uV 08:40:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.693 uVs 08:40:24 Integrated Voltage Measurement... 08:40:33 Voltage Offset Correction: v_off_ini = -383.182 uV, v_off_fin = -381.124 uV 08:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.448 uVs 08:40:37 I1X Average and RMS of Measurements VT = -115.322 +- 3.327 uVs I1X = 23.065 +- 0.666 uTm 08:40:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:40:44 Integrated Voltage Measurement... 08:40:53 Voltage Offset Correction: v_off_ini = -387.973 uV, v_off_fin = -389.013 uV 08:40:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -135.978 uVs 08:40:53 Integrated Voltage Measurement... 08:41:02 Voltage Offset Correction: v_off_ini = -373.358 uV, v_off_fin = -360.805 uV 08:41:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 158.037 uVs 08:41:02 Integrated Voltage Measurement... 08:41:11 Voltage Offset Correction: v_off_ini = -361.776 uV, v_off_fin = -378.131 uV 08:41:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -131.959 uVs 08:41:11 Integrated Voltage Measurement... 08:41:20 Voltage Offset Correction: v_off_ini = -375.196 uV, v_off_fin = -357.583 uV 08:41:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 153.988 uVs 08:41:20 Integrated Voltage Measurement... 08:41:29 Voltage Offset Correction: v_off_ini = -364.611 uV, v_off_fin = -369.969 uV 08:41:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -144.174 uVs 08:41:29 Integrated Voltage Measurement... 08:41:38 Voltage Offset Correction: v_off_ini = -359.702 uV, v_off_fin = -356.399 uV 08:41:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 143.143 uVs 08:41:42 I1Y Average and RMS of Measurements VT = -144.547 +- 1.763 uVs I1Y = -28.906 +- 0.352 uTm 08:41:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:41:50 Integrated Voltage Measurement... 08:41:59 Voltage Offset Correction: v_off_ini = -372.418 uV, v_off_fin = -378.972 uV 08:41:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -138.876 uVs 08:41:59 Integrated Voltage Measurement... 08:42:08 Voltage Offset Correction: v_off_ini = -342.488 uV, v_off_fin = -337.118 uV 08:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.192 uVs 08:42:08 Integrated Voltage Measurement... 08:42:17 Voltage Offset Correction: v_off_ini = -343.652 uV, v_off_fin = -347.472 uV 08:42:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.069 uVs 08:42:17 Integrated Voltage Measurement... 08:42:26 Voltage Offset Correction: v_off_ini = -341.483 uV, v_off_fin = -334.066 uV 08:42:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.608 uVs 08:42:26 Integrated Voltage Measurement... 08:42:35 Voltage Offset Correction: v_off_ini = -362.238 uV, v_off_fin = -355.896 uV 08:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.155 uVs 08:42:35 Integrated Voltage Measurement... 08:42:44 Voltage Offset Correction: v_off_ini = -341.966 uV, v_off_fin = -332.591 uV 08:42:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.636 uVs 08:42:46 I2X Average and RMS of Measurements VT = -132.256 +- 1.978 uVs I2X = 12.167 +- 0.182 uTm^2 08:42:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:42:54 Integrated Voltage Measurement... 08:43:03 Voltage Offset Correction: v_off_ini = -334.820 uV, v_off_fin = -340.618 uV 08:43:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.872 uVs 08:43:03 Integrated Voltage Measurement... 08:43:12 Voltage Offset Correction: v_off_ini = -348.532 uV, v_off_fin = -347.703 uV 08:43:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.841 uVs 08:43:12 Integrated Voltage Measurement... 08:43:21 Voltage Offset Correction: v_off_ini = -347.127 uV, v_off_fin = -338.213 uV 08:43:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.729 uVs 08:43:21 Integrated Voltage Measurement... 08:43:30 Voltage Offset Correction: v_off_ini = -322.983 uV, v_off_fin = -321.424 uV 08:43:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.062 uVs 08:43:30 Integrated Voltage Measurement... 08:43:39 Voltage Offset Correction: v_off_ini = -321.554 uV, v_off_fin = -323.424 uV 08:43:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.020 uVs 08:43:39 Integrated Voltage Measurement... 08:43:48 Voltage Offset Correction: v_off_ini = -325.210 uV, v_off_fin = -331.580 uV 08:43:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.305 uVs 08:43:51 I2Y Average and RMS of Measurements VT = -177.638 +- 4.056 uVs I2Y = -16.343 +- 0.373 uTm^2 08:44:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:44:06 Integrated Voltage Measurement... 08:44:15 Voltage Offset Correction: v_off_ini = -334.796 uV, v_off_fin = -327.155 uV 08:44:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.209 uVs 08:44:15 Integrated Voltage Measurement... 08:44:24 Voltage Offset Correction: v_off_ini = -356.892 uV, v_off_fin = -340.885 uV 08:44:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.497 uVs 08:44:24 Integrated Voltage Measurement... 08:44:33 Voltage Offset Correction: v_off_ini = -346.284 uV, v_off_fin = -347.875 uV 08:44:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.759 uVs 08:44:33 Integrated Voltage Measurement... 08:44:42 Voltage Offset Correction: v_off_ini = -345.823 uV, v_off_fin = -345.296 uV 08:44:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.088 uVs 08:44:42 Integrated Voltage Measurement... 08:44:51 Voltage Offset Correction: v_off_ini = -348.892 uV, v_off_fin = -351.213 uV 08:44:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.171 uVs 08:44:51 Integrated Voltage Measurement... 08:45:00 Voltage Offset Correction: v_off_ini = -336.032 uV, v_off_fin = -339.630 uV 08:45:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.901 uVs 08:45:04 I1X Average and RMS of Measurements VT = -104.104 +- 8.648 uVs I1X = 20.821 +- 1.730 uTm 08:45:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:45:11 Integrated Voltage Measurement... 08:45:20 Voltage Offset Correction: v_off_ini = -333.913 uV, v_off_fin = -348.962 uV 08:45:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -158.500 uVs 08:45:20 Integrated Voltage Measurement... 08:45:29 Voltage Offset Correction: v_off_ini = -341.981 uV, v_off_fin = -318.091 uV 08:45:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 162.475 uVs 08:45:29 Integrated Voltage Measurement... 08:45:38 Voltage Offset Correction: v_off_ini = -322.477 uV, v_off_fin = -337.907 uV 08:45:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.541 uVs 08:45:38 Integrated Voltage Measurement... 08:45:47 Voltage Offset Correction: v_off_ini = -327.675 uV, v_off_fin = -314.201 uV 08:45:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 155.272 uVs 08:45:47 Integrated Voltage Measurement... 08:45:56 Voltage Offset Correction: v_off_ini = -327.185 uV, v_off_fin = -334.910 uV 08:45:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -148.806 uVs 08:45:56 Integrated Voltage Measurement... 08:46:05 Voltage Offset Correction: v_off_ini = -331.775 uV, v_off_fin = -324.740 uV 08:46:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 158.216 uVs 08:46:09 I1Y Average and RMS of Measurements VT = -155.635 +- 3.440 uVs I1Y = -31.124 +- 0.688 uTm 08:46:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:46:17 Integrated Voltage Measurement... 08:46:26 Voltage Offset Correction: v_off_ini = -316.998 uV, v_off_fin = -314.334 uV 08:46:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -134.897 uVs 08:46:26 Integrated Voltage Measurement... 08:46:35 Voltage Offset Correction: v_off_ini = -306.164 uV, v_off_fin = -290.493 uV 08:46:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.503 uVs 08:46:35 Integrated Voltage Measurement... 08:46:44 Voltage Offset Correction: v_off_ini = -306.889 uV, v_off_fin = -323.174 uV 08:46:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.208 uVs 08:46:44 Integrated Voltage Measurement... 08:46:53 Voltage Offset Correction: v_off_ini = -317.570 uV, v_off_fin = -319.962 uV 08:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.591 uVs 08:46:53 Integrated Voltage Measurement... 08:47:02 Voltage Offset Correction: v_off_ini = -322.054 uV, v_off_fin = -325.153 uV 08:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.523 uVs 08:47:02 Integrated Voltage Measurement... 08:47:11 Voltage Offset Correction: v_off_ini = -322.892 uV, v_off_fin = -307.920 uV 08:47:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.052 uVs 08:47:14 I2X Average and RMS of Measurements VT = -128.796 +- 1.552 uVs I2X = 11.849 +- 0.143 uTm^2 08:47:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:47:21 Integrated Voltage Measurement... 08:47:30 Voltage Offset Correction: v_off_ini = -311.723 uV, v_off_fin = -306.481 uV 08:47:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.546 uVs 08:47:30 Integrated Voltage Measurement... 08:47:39 Voltage Offset Correction: v_off_ini = -313.128 uV, v_off_fin = -294.193 uV 08:47:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.813 uVs 08:47:39 Integrated Voltage Measurement... 08:47:48 Voltage Offset Correction: v_off_ini = -301.867 uV, v_off_fin = -303.525 uV 08:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.400 uVs 08:47:48 Integrated Voltage Measurement... 08:47:57 Voltage Offset Correction: v_off_ini = -302.473 uV, v_off_fin = -314.238 uV 08:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.025 uVs 08:47:57 Integrated Voltage Measurement... 08:48:06 Voltage Offset Correction: v_off_ini = -298.418 uV, v_off_fin = -297.560 uV 08:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.195 uVs 08:48:07 Integrated Voltage Measurement... 08:48:16 Voltage Offset Correction: v_off_ini = -306.282 uV, v_off_fin = -305.782 uV 08:48:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.419 uVs 08:48:18 I2Y Average and RMS of Measurements VT = -183.566 +- 7.354 uVs I2Y = -16.888 +- 0.677 uTm^2 08:48:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:48:33 Integrated Voltage Measurement... 08:48:42 Voltage Offset Correction: v_off_ini = -307.411 uV, v_off_fin = -316.115 uV 08:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.296 uVs 08:48:42 Integrated Voltage Measurement... 08:48:51 Voltage Offset Correction: v_off_ini = -327.259 uV, v_off_fin = -315.558 uV 08:48:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.617 uVs 08:48:51 Integrated Voltage Measurement... 08:49:00 Voltage Offset Correction: v_off_ini = -315.386 uV, v_off_fin = -325.754 uV 08:49:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.119 uVs 08:49:00 Integrated Voltage Measurement... 08:49:09 Voltage Offset Correction: v_off_ini = -318.798 uV, v_off_fin = -305.029 uV 08:49:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.896 uVs 08:49:09 Integrated Voltage Measurement... 08:49:18 Voltage Offset Correction: v_off_ini = -314.119 uV, v_off_fin = -316.390 uV 08:49:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.660 uVs 08:49:18 Integrated Voltage Measurement... 08:49:27 Voltage Offset Correction: v_off_ini = -311.476 uV, v_off_fin = -305.741 uV 08:49:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.620 uVs 08:49:31 I1X Average and RMS of Measurements VT = -101.868 +- 1.538 uVs I1X = 20.374 +- 0.308 uTm 08:49:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:49:38 Integrated Voltage Measurement... 08:49:47 Voltage Offset Correction: v_off_ini = -312.146 uV, v_off_fin = -318.833 uV 08:49:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.639 uVs 08:49:47 Integrated Voltage Measurement... 08:49:56 Voltage Offset Correction: v_off_ini = -328.228 uV, v_off_fin = -299.694 uV 08:49:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 170.303 uVs 08:49:56 Integrated Voltage Measurement... 08:50:05 Voltage Offset Correction: v_off_ini = -306.260 uV, v_off_fin = -324.206 uV 08:50:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.439 uVs 08:50:05 Integrated Voltage Measurement... 08:50:14 Voltage Offset Correction: v_off_ini = -331.086 uV, v_off_fin = -308.501 uV 08:50:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 162.003 uVs 08:50:14 Integrated Voltage Measurement... 08:50:23 Voltage Offset Correction: v_off_ini = -322.064 uV, v_off_fin = -328.099 uV 08:50:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.068 uVs 08:50:23 Integrated Voltage Measurement... 08:50:32 Voltage Offset Correction: v_off_ini = -325.398 uV, v_off_fin = -320.964 uV 08:50:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 170.839 uVs 08:50:36 I1Y Average and RMS of Measurements VT = -161.215 +- 4.413 uVs I1Y = -32.240 +- 0.883 uTm 08:50:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:50:44 Integrated Voltage Measurement... 08:50:53 Voltage Offset Correction: v_off_ini = -344.123 uV, v_off_fin = -348.593 uV 08:50:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.951 uVs 08:50:53 Integrated Voltage Measurement... 08:51:02 Voltage Offset Correction: v_off_ini = -316.835 uV, v_off_fin = -314.552 uV 08:51:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.915 uVs 08:51:02 Integrated Voltage Measurement... 08:51:11 Voltage Offset Correction: v_off_ini = -324.409 uV, v_off_fin = -334.409 uV 08:51:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.858 uVs 08:51:11 Integrated Voltage Measurement... 08:51:20 Voltage Offset Correction: v_off_ini = -331.451 uV, v_off_fin = -310.850 uV 08:51:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 124.563 uVs 08:51:20 Integrated Voltage Measurement... 08:51:29 Voltage Offset Correction: v_off_ini = -318.247 uV, v_off_fin = -323.012 uV 08:51:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.573 uVs 08:51:29 Integrated Voltage Measurement... 08:51:38 Voltage Offset Correction: v_off_ini = -330.092 uV, v_off_fin = -327.905 uV 08:51:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.259 uVs 08:51:41 I2X Average and RMS of Measurements VT = -125.020 +- 1.776 uVs I2X = 11.502 +- 0.163 uTm^2 08:51:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:51:48 Integrated Voltage Measurement... 08:51:57 Voltage Offset Correction: v_off_ini = -328.706 uV, v_off_fin = -346.168 uV 08:51:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.341 uVs 08:51:57 Integrated Voltage Measurement... 08:52:06 Voltage Offset Correction: v_off_ini = -341.129 uV, v_off_fin = -331.917 uV 08:52:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.509 uVs 08:52:06 Integrated Voltage Measurement... 08:52:15 Voltage Offset Correction: v_off_ini = -323.167 uV, v_off_fin = -332.886 uV 08:52:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.718 uVs 08:52:16 Integrated Voltage Measurement... 08:52:24 Voltage Offset Correction: v_off_ini = -331.947 uV, v_off_fin = -323.320 uV 08:52:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.454 uVs 08:52:25 Integrated Voltage Measurement... 08:52:34 Voltage Offset Correction: v_off_ini = -317.723 uV, v_off_fin = -333.792 uV 08:52:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.836 uVs 08:52:34 Integrated Voltage Measurement... 08:52:43 Voltage Offset Correction: v_off_ini = -329.030 uV, v_off_fin = -339.547 uV 08:52:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.278 uVs 08:52:45 I2Y Average and RMS of Measurements VT = -194.689 +- 5.879 uVs I2Y = -17.911 +- 0.541 uTm^2 08:52:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:53:00 Integrated Voltage Measurement... 08:53:09 Voltage Offset Correction: v_off_ini = -311.117 uV, v_off_fin = -327.478 uV 08:53:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.204 uVs 08:53:09 Integrated Voltage Measurement... 08:53:18 Voltage Offset Correction: v_off_ini = -331.586 uV, v_off_fin = -329.186 uV 08:53:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.425 uVs 08:53:18 Integrated Voltage Measurement... 08:53:27 Voltage Offset Correction: v_off_ini = -319.163 uV, v_off_fin = -335.397 uV 08:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.612 uVs 08:53:27 Integrated Voltage Measurement... 08:53:36 Voltage Offset Correction: v_off_ini = -335.958 uV, v_off_fin = -317.140 uV 08:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.995 uVs 08:53:36 Integrated Voltage Measurement... 08:53:45 Voltage Offset Correction: v_off_ini = -312.579 uV, v_off_fin = -315.048 uV 08:53:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.513 uVs 08:53:45 Integrated Voltage Measurement... 08:53:54 Voltage Offset Correction: v_off_ini = -308.709 uV, v_off_fin = -304.269 uV 08:53:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.243 uVs 08:53:58 I1X Average and RMS of Measurements VT = -105.499 +- 6.148 uVs I1X = 21.100 +- 1.230 uTm 08:54:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:54:05 Integrated Voltage Measurement... 08:54:14 Voltage Offset Correction: v_off_ini = -307.548 uV, v_off_fin = -311.367 uV 08:54:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.648 uVs 08:54:14 Integrated Voltage Measurement... 08:54:23 Voltage Offset Correction: v_off_ini = -310.924 uV, v_off_fin = -300.339 uV 08:54:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.940 uVs 08:54:23 Integrated Voltage Measurement... 08:54:32 Voltage Offset Correction: v_off_ini = -316.481 uV, v_off_fin = -316.896 uV 08:54:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.892 uVs 08:54:32 Integrated Voltage Measurement... 08:54:41 Voltage Offset Correction: v_off_ini = -305.508 uV, v_off_fin = -306.414 uV 08:54:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 166.537 uVs 08:54:41 Integrated Voltage Measurement... 08:54:50 Voltage Offset Correction: v_off_ini = -323.272 uV, v_off_fin = -329.299 uV 08:54:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.549 uVs 08:54:50 Integrated Voltage Measurement... 08:54:59 Voltage Offset Correction: v_off_ini = -304.916 uV, v_off_fin = -291.483 uV 08:54:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 167.949 uVs 08:55:03 I1Y Average and RMS of Measurements VT = -166.252 +- 0.803 uVs I1Y = -33.247 +- 0.161 uTm 08:55:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:55:11 Integrated Voltage Measurement... 08:55:20 Voltage Offset Correction: v_off_ini = -283.606 uV, v_off_fin = -299.031 uV 08:55:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -142.607 uVs 08:55:20 Integrated Voltage Measurement... 08:55:29 Voltage Offset Correction: v_off_ini = -293.122 uV, v_off_fin = -284.007 uV 08:55:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.903 uVs 08:55:29 Integrated Voltage Measurement... 08:55:38 Voltage Offset Correction: v_off_ini = -305.800 uV, v_off_fin = -300.161 uV 08:55:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.791 uVs 08:55:38 Integrated Voltage Measurement... 08:55:47 Voltage Offset Correction: v_off_ini = -297.040 uV, v_off_fin = -283.107 uV 08:55:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.408 uVs 08:55:47 Integrated Voltage Measurement... 08:55:56 Voltage Offset Correction: v_off_ini = -288.226 uV, v_off_fin = -294.807 uV 08:55:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.094 uVs 08:55:57 Integrated Voltage Measurement... 08:56:06 Voltage Offset Correction: v_off_ini = -274.357 uV, v_off_fin = -282.575 uV 08:56:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.066 uVs 08:56:08 I2X Average and RMS of Measurements VT = -120.312 +- 9.196 uVs I2X = 11.069 +- 0.846 uTm^2 08:56:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:56:16 Integrated Voltage Measurement... 08:56:25 Voltage Offset Correction: v_off_ini = -294.891 uV, v_off_fin = -296.720 uV 08:56:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -179.040 uVs 08:56:25 Integrated Voltage Measurement... 08:56:34 Voltage Offset Correction: v_off_ini = -285.790 uV, v_off_fin = -287.366 uV 08:56:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.613 uVs 08:56:34 Integrated Voltage Measurement... 08:56:43 Voltage Offset Correction: v_off_ini = -281.427 uV, v_off_fin = -282.868 uV 08:56:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.513 uVs 08:56:43 Integrated Voltage Measurement... 08:56:52 Voltage Offset Correction: v_off_ini = -286.375 uV, v_off_fin = -275.054 uV 08:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.288 uVs 08:56:52 Integrated Voltage Measurement... 08:57:01 Voltage Offset Correction: v_off_ini = -273.921 uV, v_off_fin = -278.290 uV 08:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.583 uVs 08:57:01 Integrated Voltage Measurement... 08:57:10 Voltage Offset Correction: v_off_ini = -266.493 uV, v_off_fin = -258.462 uV 08:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.485 uVs 08:57:12 I2Y Average and RMS of Measurements VT = -200.754 +- 13.241 uVs I2Y = -18.470 +- 1.218 uTm^2 08:57:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:57:27 Integrated Voltage Measurement... 08:57:36 Voltage Offset Correction: v_off_ini = -271.065 uV, v_off_fin = -280.170 uV 08:57:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.472 uVs 08:57:36 Integrated Voltage Measurement... 08:57:45 Voltage Offset Correction: v_off_ini = -276.028 uV, v_off_fin = -255.550 uV 08:57:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 114.562 uVs 08:57:45 Integrated Voltage Measurement... 08:57:54 Voltage Offset Correction: v_off_ini = -260.538 uV, v_off_fin = -282.611 uV 08:57:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.590 uVs 08:57:54 Integrated Voltage Measurement... 08:58:03 Voltage Offset Correction: v_off_ini = -285.505 uV, v_off_fin = -279.063 uV 08:58:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.017 uVs 08:58:03 Integrated Voltage Measurement... 08:58:12 Voltage Offset Correction: v_off_ini = -269.588 uV, v_off_fin = -276.594 uV 08:58:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.924 uVs 08:58:12 Integrated Voltage Measurement... 08:58:21 Voltage Offset Correction: v_off_ini = -268.487 uV, v_off_fin = -279.753 uV 08:58:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.561 uVs 08:58:26 I1X Average and RMS of Measurements VT = -96.688 +- 11.382 uVs I1X = 19.339 +- 2.278 uTm 08:58:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:58:32 Integrated Voltage Measurement... 08:58:41 Voltage Offset Correction: v_off_ini = -287.490 uV, v_off_fin = -300.202 uV 08:58:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.022 uVs 08:58:41 Integrated Voltage Measurement... 08:58:50 Voltage Offset Correction: v_off_ini = -276.372 uV, v_off_fin = -278.735 uV 08:58:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.275 uVs 08:58:50 Integrated Voltage Measurement... 08:58:59 Voltage Offset Correction: v_off_ini = -279.436 uV, v_off_fin = -296.115 uV 08:58:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.806 uVs 08:58:59 Integrated Voltage Measurement... 08:59:08 Voltage Offset Correction: v_off_ini = -274.250 uV, v_off_fin = -265.571 uV 08:59:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.920 uVs 08:59:09 Integrated Voltage Measurement... 08:59:18 Voltage Offset Correction: v_off_ini = -278.452 uV, v_off_fin = -283.671 uV 08:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.004 uVs 08:59:18 Integrated Voltage Measurement... 08:59:27 Voltage Offset Correction: v_off_ini = -273.122 uV, v_off_fin = -269.481 uV 08:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.257 uVs 08:59:31 I1Y Average and RMS of Measurements VT = -180.881 +- 3.577 uVs I1Y = -36.173 +- 0.715 uTm 08:59:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:59:39 Integrated Voltage Measurement... 08:59:48 Voltage Offset Correction: v_off_ini = -283.390 uV, v_off_fin = -284.298 uV 08:59:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.349 uVs 08:59:48 Integrated Voltage Measurement... 08:59:57 Voltage Offset Correction: v_off_ini = -279.511 uV, v_off_fin = -273.334 uV 08:59:57 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 124.817 uVs 08:59:57 Integrated Voltage Measurement... 09:00:06 Voltage Offset Correction: v_off_ini = -276.559 uV, v_off_fin = -295.127 uV 09:00:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.879 uVs 09:00:06 Integrated Voltage Measurement... 09:00:15 Voltage Offset Correction: v_off_ini = -282.865 uV, v_off_fin = -272.172 uV 09:00:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.766 uVs 09:00:15 Integrated Voltage Measurement... 09:00:24 Voltage Offset Correction: v_off_ini = -294.594 uV, v_off_fin = -299.806 uV 09:00:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -123.508 uVs 09:00:24 Integrated Voltage Measurement... 09:00:33 Voltage Offset Correction: v_off_ini = -278.878 uV, v_off_fin = -269.941 uV 09:00:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.454 uVs 09:00:35 I2X Average and RMS of Measurements VT = -123.462 +- 3.568 uVs I2X = 11.359 +- 0.328 uTm^2 09:00:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:00:43 Integrated Voltage Measurement... 09:00:52 Voltage Offset Correction: v_off_ini = -273.632 uV, v_off_fin = -268.670 uV 09:00:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -207.392 uVs 09:00:52 Integrated Voltage Measurement... 09:01:01 Voltage Offset Correction: v_off_ini = -265.022 uV, v_off_fin = -269.406 uV 09:01:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.867 uVs 09:01:01 Integrated Voltage Measurement... 09:01:10 Voltage Offset Correction: v_off_ini = -275.336 uV, v_off_fin = -266.833 uV 09:01:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -215.810 uVs 09:01:10 Integrated Voltage Measurement... 09:01:19 Voltage Offset Correction: v_off_ini = -273.560 uV, v_off_fin = -258.764 uV 09:01:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 210.646 uVs 09:01:19 Integrated Voltage Measurement... 09:01:28 Voltage Offset Correction: v_off_ini = -244.595 uV, v_off_fin = -253.331 uV 09:01:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.370 uVs 09:01:28 Integrated Voltage Measurement... 09:01:37 Voltage Offset Correction: v_off_ini = -233.372 uV, v_off_fin = -236.855 uV 09:01:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 204.404 uVs 09:01:40 I2Y Average and RMS of Measurements VT = -210.081 +- 2.589 uVs I2Y = -19.329 +- 0.239 uTm^2 09:01:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:01:55 Integrated Voltage Measurement... 09:02:03 Voltage Offset Correction: v_off_ini = -261.646 uV, v_off_fin = -251.722 uV 09:02:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.687 uVs 09:02:04 Integrated Voltage Measurement... 09:02:13 Voltage Offset Correction: v_off_ini = -249.354 uV, v_off_fin = -239.987 uV 09:02:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.800 uVs 09:02:13 Integrated Voltage Measurement... 09:02:22 Voltage Offset Correction: v_off_ini = -238.055 uV, v_off_fin = -252.189 uV 09:02:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.710 uVs 09:02:22 Integrated Voltage Measurement... 09:02:31 Voltage Offset Correction: v_off_ini = -241.215 uV, v_off_fin = -248.856 uV 09:02:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.860 uVs 09:02:31 Integrated Voltage Measurement... 09:02:40 Voltage Offset Correction: v_off_ini = -249.131 uV, v_off_fin = -253.066 uV 09:02:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.304 uVs 09:02:40 Integrated Voltage Measurement... 09:02:49 Voltage Offset Correction: v_off_ini = -237.707 uV, v_off_fin = -238.782 uV 09:02:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.539 uVs 09:02:53 I1X Average and RMS of Measurements VT = -88.150 +- 5.060 uVs I1X = 17.630 +- 1.012 uTm 09:02:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:03:00 Integrated Voltage Measurement... 09:03:09 Voltage Offset Correction: v_off_ini = -241.581 uV, v_off_fin = -247.818 uV 09:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.099 uVs 09:03:09 Integrated Voltage Measurement... 09:03:18 Voltage Offset Correction: v_off_ini = -225.920 uV, v_off_fin = -211.939 uV 09:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.259 uVs 09:03:18 Integrated Voltage Measurement... 09:03:27 Voltage Offset Correction: v_off_ini = -230.434 uV, v_off_fin = -243.034 uV 09:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.484 uVs 09:03:27 Integrated Voltage Measurement... 09:03:36 Voltage Offset Correction: v_off_ini = -214.491 uV, v_off_fin = -201.638 uV 09:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.733 uVs 09:03:36 Integrated Voltage Measurement... 09:03:45 Voltage Offset Correction: v_off_ini = -192.403 uV, v_off_fin = -203.339 uV 09:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.511 uVs 09:03:45 Integrated Voltage Measurement... 09:03:54 Voltage Offset Correction: v_off_ini = -197.525 uV, v_off_fin = -210.023 uV 09:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.268 uVs 09:03:58 I1Y Average and RMS of Measurements VT = -185.226 +- 2.945 uVs I1Y = -37.043 +- 0.589 uTm 09:04:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:04:06 Integrated Voltage Measurement... 09:04:15 Voltage Offset Correction: v_off_ini = -232.681 uV, v_off_fin = -237.858 uV 09:04:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.850 uVs 09:04:15 Integrated Voltage Measurement... 09:04:24 Voltage Offset Correction: v_off_ini = -225.493 uV, v_off_fin = -209.901 uV 09:04:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.863 uVs 09:04:24 Integrated Voltage Measurement... 09:04:33 Voltage Offset Correction: v_off_ini = -236.292 uV, v_off_fin = -237.383 uV 09:04:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.084 uVs 09:04:33 Integrated Voltage Measurement... 09:04:42 Voltage Offset Correction: v_off_ini = -227.049 uV, v_off_fin = -210.297 uV 09:04:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 119.306 uVs 09:04:42 Integrated Voltage Measurement... 09:04:51 Voltage Offset Correction: v_off_ini = -221.637 uV, v_off_fin = -220.828 uV 09:04:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.690 uVs 09:04:51 Integrated Voltage Measurement... 09:05:00 Voltage Offset Correction: v_off_ini = -212.527 uV, v_off_fin = -212.567 uV 09:05:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.210 uVs 09:05:02 I2X Average and RMS of Measurements VT = -106.834 +- 3.383 uVs I2X = 9.829 +- 0.311 uTm^2 09:05:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:05:10 Integrated Voltage Measurement... 09:05:19 Voltage Offset Correction: v_off_ini = -212.873 uV, v_off_fin = -220.290 uV 09:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.771 uVs 09:05:19 Integrated Voltage Measurement... 09:05:28 Voltage Offset Correction: v_off_ini = -218.364 uV, v_off_fin = -220.067 uV 09:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.940 uVs 09:05:28 Integrated Voltage Measurement... 09:05:37 Voltage Offset Correction: v_off_ini = -211.894 uV, v_off_fin = -218.588 uV 09:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.187 uVs 09:05:37 Integrated Voltage Measurement... 09:05:46 Voltage Offset Correction: v_off_ini = -199.073 uV, v_off_fin = -208.005 uV 09:05:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.138 uVs 09:05:46 Integrated Voltage Measurement... 09:05:55 Voltage Offset Correction: v_off_ini = -212.883 uV, v_off_fin = -220.053 uV 09:05:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.164 uVs 09:05:55 Integrated Voltage Measurement... 09:06:04 Voltage Offset Correction: v_off_ini = -218.721 uV, v_off_fin = -216.908 uV 09:06:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.108 uVs 09:06:07 I2Y Average and RMS of Measurements VT = -219.385 +- 4.276 uVs I2Y = -20.183 +- 0.393 uTm^2 09:06:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:06:22 Integrated Voltage Measurement... 09:06:31 Voltage Offset Correction: v_off_ini = -239.348 uV, v_off_fin = -228.348 uV 09:06:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.441 uVs 09:06:31 Integrated Voltage Measurement... 09:06:40 Voltage Offset Correction: v_off_ini = -223.618 uV, v_off_fin = -213.525 uV 09:06:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.661 uVs 09:06:40 Integrated Voltage Measurement... 09:06:49 Voltage Offset Correction: v_off_ini = -211.142 uV, v_off_fin = -218.828 uV 09:06:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.829 uVs 09:06:49 Integrated Voltage Measurement... 09:06:58 Voltage Offset Correction: v_off_ini = -211.786 uV, v_off_fin = -214.284 uV 09:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.529 uVs 09:06:58 Integrated Voltage Measurement... 09:07:07 Voltage Offset Correction: v_off_ini = -206.331 uV, v_off_fin = -216.508 uV 09:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.567 uVs 09:07:07 Integrated Voltage Measurement... 09:07:16 Voltage Offset Correction: v_off_ini = -223.588 uV, v_off_fin = -219.707 uV 09:07:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.430 uVs 09:07:20 I1X Average and RMS of Measurements VT = -92.243 +- 9.134 uVs I1X = 18.449 +- 1.827 uTm 09:07:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:07:27 Integrated Voltage Measurement... 09:07:36 Voltage Offset Correction: v_off_ini = -218.046 uV, v_off_fin = -237.740 uV 09:07:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.187 uVs 09:07:36 Integrated Voltage Measurement... 09:07:45 Voltage Offset Correction: v_off_ini = -206.576 uV, v_off_fin = -204.145 uV 09:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.330 uVs 09:07:45 Integrated Voltage Measurement... 09:07:54 Voltage Offset Correction: v_off_ini = -208.919 uV, v_off_fin = -220.345 uV 09:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.184 uVs 09:07:54 Integrated Voltage Measurement... 09:08:03 Voltage Offset Correction: v_off_ini = -195.966 uV, v_off_fin = -185.358 uV 09:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.320 uVs 09:08:03 Integrated Voltage Measurement... 09:08:12 Voltage Offset Correction: v_off_ini = -202.462 uV, v_off_fin = -213.488 uV 09:08:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -192.791 uVs 09:08:12 Integrated Voltage Measurement... 09:08:21 Voltage Offset Correction: v_off_ini = -206.610 uV, v_off_fin = -185.971 uV 09:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.571 uVs 09:08:25 I1Y Average and RMS of Measurements VT = -195.897 +- 6.735 uVs I1Y = -39.175 +- 1.345 uTm 09:08:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:08:33 Integrated Voltage Measurement... 09:08:42 Voltage Offset Correction: v_off_ini = -210.733 uV, v_off_fin = -218.460 uV 09:08:42 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -124.060 uVs 09:08:42 Integrated Voltage Measurement... 09:08:51 Voltage Offset Correction: v_off_ini = -220.369 uV, v_off_fin = -199.369 uV 09:08:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.361 uVs 09:08:51 Integrated Voltage Measurement... 09:09:00 Voltage Offset Correction: v_off_ini = -220.219 uV, v_off_fin = -228.113 uV 09:09:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.309 uVs 09:09:00 Integrated Voltage Measurement... 09:09:09 Voltage Offset Correction: v_off_ini = -219.355 uV, v_off_fin = -205.723 uV 09:09:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.413 uVs 09:09:09 Integrated Voltage Measurement... 09:09:18 Voltage Offset Correction: v_off_ini = -216.553 uV, v_off_fin = -224.433 uV 09:09:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -119.814 uVs 09:09:18 Integrated Voltage Measurement... 09:09:27 Voltage Offset Correction: v_off_ini = -228.891 uV, v_off_fin = -216.924 uV 09:09:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.580 uVs 09:09:29 I2X Average and RMS of Measurements VT = -113.089 +- 6.854 uVs I2X = 10.405 +- 0.630 uTm^2 09:09:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:09:37 Integrated Voltage Measurement... 09:09:46 Voltage Offset Correction: v_off_ini = -225.072 uV, v_off_fin = -235.254 uV 09:09:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -209.301 uVs 09:09:46 Integrated Voltage Measurement... 09:09:55 Voltage Offset Correction: v_off_ini = -216.786 uV, v_off_fin = -207.723 uV 09:09:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.989 uVs 09:09:55 Integrated Voltage Measurement... 09:10:04 Voltage Offset Correction: v_off_ini = -220.966 uV, v_off_fin = -229.294 uV 09:10:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.006 uVs 09:10:04 Integrated Voltage Measurement... 09:10:13 Voltage Offset Correction: v_off_ini = -226.727 uV, v_off_fin = -230.333 uV 09:10:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.180 uVs 09:10:13 Integrated Voltage Measurement... 09:10:22 Voltage Offset Correction: v_off_ini = -222.008 uV, v_off_fin = -225.166 uV 09:10:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.388 uVs 09:10:22 Integrated Voltage Measurement... 09:10:31 Voltage Offset Correction: v_off_ini = -217.551 uV, v_off_fin = -217.079 uV 09:10:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.479 uVs 09:10:34 I2Y Average and RMS of Measurements VT = -228.057 +- 1.433 uVs I2Y = -20.982 +- 0.131 uTm^2 09:10:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:10:49 Integrated Voltage Measurement... 09:10:58 Voltage Offset Correction: v_off_ini = -193.128 uV, v_off_fin = -203.013 uV 09:10:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.416 uVs 09:10:58 Integrated Voltage Measurement... 09:11:07 Voltage Offset Correction: v_off_ini = -203.079 uV, v_off_fin = -211.932 uV 09:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.909 uVs 09:11:07 Integrated Voltage Measurement... 09:11:16 Voltage Offset Correction: v_off_ini = -215.320 uV, v_off_fin = -214.727 uV 09:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.569 uVs 09:11:16 Integrated Voltage Measurement... 09:11:25 Voltage Offset Correction: v_off_ini = -201.508 uV, v_off_fin = -193.644 uV 09:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.977 uVs 09:11:25 Integrated Voltage Measurement... 09:11:34 Voltage Offset Correction: v_off_ini = -213.581 uV, v_off_fin = -203.550 uV 09:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.242 uVs 09:11:34 Integrated Voltage Measurement... 09:11:43 Voltage Offset Correction: v_off_ini = -206.633 uV, v_off_fin = -211.828 uV 09:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.294 uVs 09:11:47 I1X Average and RMS of Measurements VT = -91.901 +- 1.389 uVs I1X = 18.380 +- 0.278 uTm 09:11:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:11:54 Integrated Voltage Measurement... 09:12:03 Voltage Offset Correction: v_off_ini = -213.243 uV, v_off_fin = -208.510 uV 09:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.326 uVs 09:12:03 Integrated Voltage Measurement... 09:12:12 Voltage Offset Correction: v_off_ini = -221.493 uV, v_off_fin = -194.211 uV 09:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.072 uVs 09:12:12 Integrated Voltage Measurement... 09:12:21 Voltage Offset Correction: v_off_ini = -211.335 uV, v_off_fin = -230.731 uV 09:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.375 uVs 09:12:21 Integrated Voltage Measurement... 09:12:30 Voltage Offset Correction: v_off_ini = -213.166 uV, v_off_fin = -204.211 uV 09:12:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.313 uVs 09:12:30 Integrated Voltage Measurement... 09:12:39 Voltage Offset Correction: v_off_ini = -217.117 uV, v_off_fin = -226.772 uV 09:12:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.555 uVs 09:12:39 Integrated Voltage Measurement... 09:12:48 Voltage Offset Correction: v_off_ini = -211.730 uV, v_off_fin = -205.083 uV 09:12:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.811 uVs 09:12:52 I1Y Average and RMS of Measurements VT = -200.575 +- 8.508 uVs I1Y = -40.113 +- 1.702 uTm 09:12:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:13:00 Integrated Voltage Measurement... 09:13:09 Voltage Offset Correction: v_off_ini = -223.005 uV, v_off_fin = -224.698 uV 09:13:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -113.034 uVs 09:13:09 Integrated Voltage Measurement... 09:13:18 Voltage Offset Correction: v_off_ini = -212.826 uV, v_off_fin = -200.477 uV 09:13:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.075 uVs 09:13:18 Integrated Voltage Measurement... 09:13:27 Voltage Offset Correction: v_off_ini = -218.370 uV, v_off_fin = -219.147 uV 09:13:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.982 uVs 09:13:27 Integrated Voltage Measurement... 09:13:36 Voltage Offset Correction: v_off_ini = -205.959 uV, v_off_fin = -186.558 uV 09:13:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.914 uVs 09:13:36 Integrated Voltage Measurement... 09:13:45 Voltage Offset Correction: v_off_ini = -186.296 uV, v_off_fin = -190.041 uV 09:13:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -137.294 uVs 09:13:45 Integrated Voltage Measurement... 09:13:54 Voltage Offset Correction: v_off_ini = -193.889 uV, v_off_fin = -199.397 uV 09:13:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.415 uVs 09:13:56 I2X Average and RMS of Measurements VT = -113.952 +- 7.194 uVs I2X = 10.484 +- 0.661 uTm^2 09:14:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:14:04 Integrated Voltage Measurement... 09:14:13 Voltage Offset Correction: v_off_ini = -229.257 uV, v_off_fin = -225.311 uV 09:14:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -219.816 uVs 09:14:13 Integrated Voltage Measurement... 09:14:22 Voltage Offset Correction: v_off_ini = -230.804 uV, v_off_fin = -224.945 uV 09:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.475 uVs 09:14:22 Integrated Voltage Measurement... 09:14:31 Voltage Offset Correction: v_off_ini = -227.506 uV, v_off_fin = -226.049 uV 09:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.042 uVs 09:14:31 Integrated Voltage Measurement... 09:14:40 Voltage Offset Correction: v_off_ini = -211.815 uV, v_off_fin = -203.555 uV 09:14:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.760 uVs 09:14:40 Integrated Voltage Measurement... 09:14:49 Voltage Offset Correction: v_off_ini = -210.390 uV, v_off_fin = -215.669 uV 09:14:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.064 uVs 09:14:49 Integrated Voltage Measurement... 09:14:58 Voltage Offset Correction: v_off_ini = -215.401 uV, v_off_fin = -200.219 uV 09:14:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 223.916 uVs 09:15:01 I2Y Average and RMS of Measurements VT = -226.179 +- 2.617 uVs I2Y = -20.808 +- 0.241 uTm^2 09:15:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:15:16 Integrated Voltage Measurement... 09:15:25 Voltage Offset Correction: v_off_ini = -213.771 uV, v_off_fin = -220.638 uV 09:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.457 uVs 09:15:25 Integrated Voltage Measurement... 09:15:34 Voltage Offset Correction: v_off_ini = -224.905 uV, v_off_fin = -215.035 uV 09:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.760 uVs 09:15:34 Integrated Voltage Measurement... 09:15:43 Voltage Offset Correction: v_off_ini = -219.391 uV, v_off_fin = -218.880 uV 09:15:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.375 uVs 09:15:43 Integrated Voltage Measurement... 09:15:52 Voltage Offset Correction: v_off_ini = -197.117 uV, v_off_fin = -188.925 uV 09:15:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.436 uVs 09:15:52 Integrated Voltage Measurement... 09:16:01 Voltage Offset Correction: v_off_ini = -195.611 uV, v_off_fin = -204.654 uV 09:16:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.485 uVs 09:16:01 Integrated Voltage Measurement... 09:16:10 Voltage Offset Correction: v_off_ini = -201.011 uV, v_off_fin = -193.679 uV 09:16:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.581 uVs 09:16:14 I1X Average and RMS of Measurements VT = -91.516 +- 3.323 uVs I1X = 18.303 +- 0.665 uTm 09:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:16:21 Integrated Voltage Measurement... 09:16:30 Voltage Offset Correction: v_off_ini = -204.355 uV, v_off_fin = -215.194 uV 09:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.786 uVs 09:16:30 Integrated Voltage Measurement... 09:16:39 Voltage Offset Correction: v_off_ini = -196.198 uV, v_off_fin = -201.850 uV 09:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.650 uVs 09:16:39 Integrated Voltage Measurement... 09:16:48 Voltage Offset Correction: v_off_ini = -199.159 uV, v_off_fin = -211.710 uV 09:16:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.319 uVs 09:16:48 Integrated Voltage Measurement... 09:16:57 Voltage Offset Correction: v_off_ini = -182.502 uV, v_off_fin = -183.753 uV 09:16:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.943 uVs 09:16:57 Integrated Voltage Measurement... 09:17:06 Voltage Offset Correction: v_off_ini = -196.506 uV, v_off_fin = -214.901 uV 09:17:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.623 uVs 09:17:06 Integrated Voltage Measurement... 09:17:15 Voltage Offset Correction: v_off_ini = -207.970 uV, v_off_fin = -183.243 uV 09:17:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.505 uVs 09:17:19 I1Y Average and RMS of Measurements VT = -203.804 +- 1.966 uVs I1Y = -40.759 +- 0.393 uTm 09:17:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:17:27 Integrated Voltage Measurement... 09:17:36 Voltage Offset Correction: v_off_ini = -203.366 uV, v_off_fin = -211.822 uV 09:17:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.002 uVs 09:17:36 Integrated Voltage Measurement... 09:17:45 Voltage Offset Correction: v_off_ini = -211.507 uV, v_off_fin = -199.044 uV 09:17:45 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 114.984 uVs 09:17:45 Integrated Voltage Measurement... 09:17:54 Voltage Offset Correction: v_off_ini = -206.161 uV, v_off_fin = -198.180 uV 09:17:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.406 uVs 09:17:54 Integrated Voltage Measurement... 09:18:03 Voltage Offset Correction: v_off_ini = -175.003 uV, v_off_fin = -172.046 uV 09:18:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.426 uVs 09:18:03 Integrated Voltage Measurement... 09:18:12 Voltage Offset Correction: v_off_ini = -180.509 uV, v_off_fin = -212.754 uV 09:18:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -120.185 uVs 09:18:12 Integrated Voltage Measurement... 09:18:21 Voltage Offset Correction: v_off_ini = -187.389 uV, v_off_fin = -180.749 uV 09:18:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.108 uVs 09:18:24 I2X Average and RMS of Measurements VT = -118.685 +- 2.806 uVs I2X = 10.920 +- 0.258 uTm^2 09:18:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:18:31 Integrated Voltage Measurement... 09:18:40 Voltage Offset Correction: v_off_ini = -174.864 uV, v_off_fin = -168.566 uV 09:18:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.665 uVs 09:18:40 Integrated Voltage Measurement... 09:18:49 Voltage Offset Correction: v_off_ini = -161.520 uV, v_off_fin = -153.699 uV 09:18:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.272 uVs 09:18:49 Integrated Voltage Measurement... 09:18:58 Voltage Offset Correction: v_off_ini = -165.130 uV, v_off_fin = -163.484 uV 09:18:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.818 uVs 09:18:59 Integrated Voltage Measurement... 09:19:07 Voltage Offset Correction: v_off_ini = -166.733 uV, v_off_fin = -177.656 uV 09:19:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.065 uVs 09:19:08 Integrated Voltage Measurement... 09:19:17 Voltage Offset Correction: v_off_ini = -176.102 uV, v_off_fin = -177.017 uV 09:19:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.190 uVs 09:19:17 Integrated Voltage Measurement... 09:19:26 Voltage Offset Correction: v_off_ini = -176.171 uV, v_off_fin = -184.306 uV 09:19:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.427 uVs 09:19:28 I2Y Average and RMS of Measurements VT = -238.073 +- 4.853 uVs I2Y = -21.903 +- 0.446 uTm^2 09:19:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:19:44 Integrated Voltage Measurement... 09:19:53 Voltage Offset Correction: v_off_ini = -179.684 uV, v_off_fin = -173.887 uV 09:19:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.230 uVs 09:19:53 Integrated Voltage Measurement... 09:20:02 Voltage Offset Correction: v_off_ini = -152.325 uV, v_off_fin = -161.366 uV 09:20:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.761 uVs 09:20:02 Integrated Voltage Measurement... 09:20:11 Voltage Offset Correction: v_off_ini = -171.522 uV, v_off_fin = -174.276 uV 09:20:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.602 uVs 09:20:11 Integrated Voltage Measurement... 09:20:20 Voltage Offset Correction: v_off_ini = -168.695 uV, v_off_fin = -162.507 uV 09:20:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.529 uVs 09:20:20 Integrated Voltage Measurement... 09:20:29 Voltage Offset Correction: v_off_ini = -176.876 uV, v_off_fin = -171.493 uV 09:20:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.664 uVs 09:20:29 Integrated Voltage Measurement... 09:20:38 Voltage Offset Correction: v_off_ini = -159.240 uV, v_off_fin = -167.563 uV 09:20:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.975 uVs 09:20:43 I1X Average and RMS of Measurements VT = -77.627 +- 6.122 uVs I1X = 15.525 +- 1.224 uTm 09:20:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:20:49 Integrated Voltage Measurement... 09:20:58 Voltage Offset Correction: v_off_ini = -152.324 uV, v_off_fin = -159.249 uV 09:20:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.524 uVs 09:20:58 Integrated Voltage Measurement... 09:21:07 Voltage Offset Correction: v_off_ini = -138.318 uV, v_off_fin = -140.327 uV 09:21:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.057 uVs 09:21:07 Integrated Voltage Measurement... 09:21:16 Voltage Offset Correction: v_off_ini = -152.605 uV, v_off_fin = -170.478 uV 09:21:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.621 uVs 09:21:16 Integrated Voltage Measurement... 09:21:25 Voltage Offset Correction: v_off_ini = -152.166 uV, v_off_fin = -144.412 uV 09:21:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.426 uVs 09:21:25 Integrated Voltage Measurement... 09:21:34 Voltage Offset Correction: v_off_ini = -160.241 uV, v_off_fin = -180.293 uV 09:21:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.770 uVs 09:21:34 Integrated Voltage Measurement... 09:21:43 Voltage Offset Correction: v_off_ini = -171.345 uV, v_off_fin = -133.216 uV 09:21:43 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 232.828 uVs 09:21:48 I1Y Average and RMS of Measurements VT = -217.704 +- 3.116 uVs I1Y = -43.536 +- 0.625 uTm 09:21:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:21:55 Integrated Voltage Measurement... 09:22:04 Voltage Offset Correction: v_off_ini = -153.532 uV, v_off_fin = -175.093 uV 09:22:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.732 uVs 09:22:04 Integrated Voltage Measurement... 09:22:13 Voltage Offset Correction: v_off_ini = -159.952 uV, v_off_fin = -152.470 uV 09:22:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.117 uVs 09:22:13 Integrated Voltage Measurement... 09:22:22 Voltage Offset Correction: v_off_ini = -171.482 uV, v_off_fin = -172.830 uV 09:22:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.252 uVs 09:22:22 Integrated Voltage Measurement... 09:22:31 Voltage Offset Correction: v_off_ini = -171.253 uV, v_off_fin = -151.910 uV 09:22:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.983 uVs 09:22:31 Integrated Voltage Measurement... 09:22:40 Voltage Offset Correction: v_off_ini = -162.850 uV, v_off_fin = -168.357 uV 09:22:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.289 uVs 09:22:40 Integrated Voltage Measurement... 09:22:49 Voltage Offset Correction: v_off_ini = -167.518 uV, v_off_fin = -151.264 uV 09:22:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.754 uVs 09:22:52 I2X Average and RMS of Measurements VT = -111.855 +- 14.957 uVs I2X = 10.291 +- 1.376 uTm^2 09:22:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:23:00 Integrated Voltage Measurement... 09:23:09 Voltage Offset Correction: v_off_ini = -166.991 uV, v_off_fin = -165.770 uV 09:23:09 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -232.425 uVs 09:23:09 Integrated Voltage Measurement... 09:23:18 Voltage Offset Correction: v_off_ini = -155.097 uV, v_off_fin = -145.974 uV 09:23:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 247.031 uVs 09:23:18 Integrated Voltage Measurement... 09:23:27 Voltage Offset Correction: v_off_ini = -142.418 uV, v_off_fin = -145.706 uV 09:23:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.540 uVs 09:23:27 Integrated Voltage Measurement... 09:23:36 Voltage Offset Correction: v_off_ini = -142.487 uV, v_off_fin = -146.340 uV 09:23:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.504 uVs 09:23:36 Integrated Voltage Measurement... 09:23:45 Voltage Offset Correction: v_off_ini = -164.233 uV, v_off_fin = -146.446 uV 09:23:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.414 uVs 09:23:45 Integrated Voltage Measurement... 09:23:54 Voltage Offset Correction: v_off_ini = -145.715 uV, v_off_fin = -149.648 uV 09:23:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.399 uVs 09:23:56 I2Y Average and RMS of Measurements VT = -239.885 +- 3.221 uVs I2Y = -22.069 +- 0.296 uTm^2 09:24:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:24:12 Integrated Voltage Measurement... 09:24:21 Voltage Offset Correction: v_off_ini = -148.491 uV, v_off_fin = -152.311 uV 09:24:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.237 uVs 09:24:21 Integrated Voltage Measurement... 09:24:30 Voltage Offset Correction: v_off_ini = -150.590 uV, v_off_fin = -140.252 uV 09:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.908 uVs 09:24:31 Integrated Voltage Measurement... 09:24:39 Voltage Offset Correction: v_off_ini = -158.665 uV, v_off_fin = -142.373 uV 09:24:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.354 uVs 09:24:40 Integrated Voltage Measurement... 09:24:49 Voltage Offset Correction: v_off_ini = -124.227 uV, v_off_fin = -126.899 uV 09:24:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.987 uVs 09:24:49 Integrated Voltage Measurement... 09:24:58 Voltage Offset Correction: v_off_ini = -145.758 uV, v_off_fin = -145.328 uV 09:24:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.623 uVs 09:24:58 Integrated Voltage Measurement... 09:25:07 Voltage Offset Correction: v_off_ini = -141.347 uV, v_off_fin = -147.838 uV 09:25:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.827 uVs 09:25:11 I1X Average and RMS of Measurements VT = -87.656 +- 8.123 uVs I1X = 17.531 +- 1.625 uTm 09:25:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:25:18 Integrated Voltage Measurement... 09:25:27 Voltage Offset Correction: v_off_ini = -155.977 uV, v_off_fin = -180.931 uV 09:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.912 uVs 09:25:27 Integrated Voltage Measurement... 09:25:36 Voltage Offset Correction: v_off_ini = -155.081 uV, v_off_fin = -147.217 uV 09:25:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.707 uVs 09:25:36 Integrated Voltage Measurement... 09:25:45 Voltage Offset Correction: v_off_ini = -155.080 uV, v_off_fin = -170.984 uV 09:25:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.641 uVs 09:25:45 Integrated Voltage Measurement... 09:25:54 Voltage Offset Correction: v_off_ini = -148.832 uV, v_off_fin = -146.897 uV 09:25:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.849 uVs 09:25:54 Integrated Voltage Measurement... 09:26:03 Voltage Offset Correction: v_off_ini = -146.710 uV, v_off_fin = -177.056 uV 09:26:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.703 uVs 09:26:03 Integrated Voltage Measurement... 09:26:12 Voltage Offset Correction: v_off_ini = -151.863 uV, v_off_fin = -147.769 uV 09:26:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.723 uVs 09:26:16 I1Y Average and RMS of Measurements VT = -218.756 +- 2.512 uVs I1Y = -43.748 +- 0.502 uTm 09:26:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:26:24 Integrated Voltage Measurement... 09:26:33 Voltage Offset Correction: v_off_ini = -155.259 uV, v_off_fin = -156.824 uV 09:26:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -119.241 uVs 09:26:33 Integrated Voltage Measurement... 09:26:42 Voltage Offset Correction: v_off_ini = -151.518 uV, v_off_fin = -135.220 uV 09:26:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.026 uVs 09:26:42 Integrated Voltage Measurement... 09:26:51 Voltage Offset Correction: v_off_ini = -158.072 uV, v_off_fin = -163.895 uV 09:26:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.777 uVs 09:26:51 Integrated Voltage Measurement... 09:27:00 Voltage Offset Correction: v_off_ini = -162.770 uV, v_off_fin = -146.129 uV 09:27:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.101 uVs 09:27:00 Integrated Voltage Measurement... 09:27:09 Voltage Offset Correction: v_off_ini = -156.553 uV, v_off_fin = -167.733 uV 09:27:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.586 uVs 09:27:09 Integrated Voltage Measurement... 09:27:18 Voltage Offset Correction: v_off_ini = -161.447 uV, v_off_fin = -146.960 uV 09:27:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.069 uVs 09:27:20 I2X Average and RMS of Measurements VT = -112.133 +- 9.410 uVs I2X = 10.316 +- 0.866 uTm^2 09:27:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:27:28 Integrated Voltage Measurement... 09:27:37 Voltage Offset Correction: v_off_ini = -160.620 uV, v_off_fin = -167.658 uV 09:27:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.723 uVs 09:27:37 Integrated Voltage Measurement... 09:27:46 Voltage Offset Correction: v_off_ini = -165.345 uV, v_off_fin = -172.487 uV 09:27:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.505 uVs 09:27:46 Integrated Voltage Measurement... 09:27:55 Voltage Offset Correction: v_off_ini = -168.581 uV, v_off_fin = -170.495 uV 09:27:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.146 uVs 09:27:55 Integrated Voltage Measurement... 09:28:04 Voltage Offset Correction: v_off_ini = -164.953 uV, v_off_fin = -152.432 uV 09:28:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.625 uVs 09:28:04 Integrated Voltage Measurement... 09:28:13 Voltage Offset Correction: v_off_ini = -165.711 uV, v_off_fin = -149.243 uV 09:28:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.685 uVs 09:28:13 Integrated Voltage Measurement... 09:28:22 Voltage Offset Correction: v_off_ini = -165.816 uV, v_off_fin = -158.763 uV 09:28:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.416 uVs 09:28:25 I2Y Average and RMS of Measurements VT = -241.683 +- 7.192 uVs I2Y = -22.235 +- 0.662 uTm^2 09:28:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:28:43 Integrated Voltage Measurement... 09:28:52 Voltage Offset Correction: v_off_ini = -160.554 uV, v_off_fin = -171.604 uV 09:28:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.870 uVs 09:28:52 Integrated Voltage Measurement... 09:29:01 Voltage Offset Correction: v_off_ini = -164.216 uV, v_off_fin = -169.858 uV 09:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.463 uVs 09:29:01 Integrated Voltage Measurement... 09:29:10 Voltage Offset Correction: v_off_ini = -172.075 uV, v_off_fin = -177.653 uV 09:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.061 uVs 09:29:10 Integrated Voltage Measurement... 09:29:19 Voltage Offset Correction: v_off_ini = -168.799 uV, v_off_fin = -174.657 uV 09:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.103 uVs 09:29:19 Integrated Voltage Measurement... 09:29:28 Voltage Offset Correction: v_off_ini = -185.309 uV, v_off_fin = -175.811 uV 09:29:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.129 uVs 09:29:28 Integrated Voltage Measurement... 09:29:37 Voltage Offset Correction: v_off_ini = -168.466 uV, v_off_fin = -159.333 uV 09:29:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.050 uVs 09:29:41 I1X Average and RMS of Measurements VT = -93.613 +- 5.727 uVs I1X = 18.723 +- 1.145 uTm 09:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:29:48 Integrated Voltage Measurement... 09:29:57 Voltage Offset Correction: v_off_ini = -146.944 uV, v_off_fin = -154.814 uV 09:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.174 uVs 09:29:57 Integrated Voltage Measurement... 09:30:06 Voltage Offset Correction: v_off_ini = -134.371 uV, v_off_fin = -125.442 uV 09:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.248 uVs 09:30:06 Integrated Voltage Measurement... 09:30:15 Voltage Offset Correction: v_off_ini = -151.336 uV, v_off_fin = -160.511 uV 09:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -214.641 uVs 09:30:15 Integrated Voltage Measurement... 09:30:24 Voltage Offset Correction: v_off_ini = -135.396 uV, v_off_fin = -128.580 uV 09:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.483 uVs 09:30:24 Integrated Voltage Measurement... 09:30:33 Voltage Offset Correction: v_off_ini = -146.706 uV, v_off_fin = -148.109 uV 09:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.131 uVs 09:30:33 Integrated Voltage Measurement... 09:30:42 Voltage Offset Correction: v_off_ini = -134.555 uV, v_off_fin = -136.325 uV 09:30:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 230.060 uVs 09:30:46 I1Y Average and RMS of Measurements VT = -220.790 +- 6.515 uVs I1Y = -44.153 +- 1.304 uTm 09:30:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:30:54 Integrated Voltage Measurement... 09:31:03 Voltage Offset Correction: v_off_ini = -124.910 uV, v_off_fin = -147.748 uV 09:31:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.813 uVs 09:31:03 Integrated Voltage Measurement... 09:31:12 Voltage Offset Correction: v_off_ini = -126.595 uV, v_off_fin = -117.551 uV 09:31:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.518 uVs 09:31:12 Integrated Voltage Measurement... 09:31:21 Voltage Offset Correction: v_off_ini = -129.829 uV, v_off_fin = -134.772 uV 09:31:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -89.800 uVs 09:31:21 Integrated Voltage Measurement... 09:31:30 Voltage Offset Correction: v_off_ini = -112.799 uV, v_off_fin = -116.541 uV 09:31:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.904 uVs 09:31:30 Integrated Voltage Measurement... 09:31:39 Voltage Offset Correction: v_off_ini = -111.983 uV, v_off_fin = -130.619 uV 09:31:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.521 uVs 09:31:39 Integrated Voltage Measurement... 09:31:48 Voltage Offset Correction: v_off_ini = -127.959 uV, v_off_fin = -113.222 uV 09:31:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.550 uVs 09:31:51 I2X Average and RMS of Measurements VT = -98.518 +- 7.424 uVs I2X = 9.064 +- 0.683 uTm^2 09:31:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:31:58 Integrated Voltage Measurement... 09:32:07 Voltage Offset Correction: v_off_ini = -133.880 uV, v_off_fin = -128.571 uV 09:32:07 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -246.014 uVs 09:32:07 Integrated Voltage Measurement... 09:32:16 Voltage Offset Correction: v_off_ini = -134.945 uV, v_off_fin = -138.574 uV 09:32:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.137 uVs 09:32:16 Integrated Voltage Measurement... 09:32:25 Voltage Offset Correction: v_off_ini = -142.132 uV, v_off_fin = -122.516 uV 09:32:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.512 uVs 09:32:25 Integrated Voltage Measurement... 09:32:34 Voltage Offset Correction: v_off_ini = -123.169 uV, v_off_fin = -109.883 uV 09:32:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.114 uVs 09:32:34 Integrated Voltage Measurement... 09:32:43 Voltage Offset Correction: v_off_ini = -114.898 uV, v_off_fin = -114.238 uV 09:32:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.272 uVs 09:32:43 Integrated Voltage Measurement... 09:32:52 Voltage Offset Correction: v_off_ini = -106.878 uV, v_off_fin = -106.324 uV 09:32:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.997 uVs 09:32:55 I2Y Average and RMS of Measurements VT = -246.174 +- 5.901 uVs I2Y = -22.648 +- 0.542 uTm^2 09:33:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:33:13 Integrated Voltage Measurement... 09:33:22 Voltage Offset Correction: v_off_ini = -106.261 uV, v_off_fin = -105.924 uV 09:33:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -80.789 uVs 09:33:22 Integrated Voltage Measurement... 09:33:31 Voltage Offset Correction: v_off_ini = -119.888 uV, v_off_fin = -116.314 uV 09:33:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.168 uVs 09:33:31 Integrated Voltage Measurement... 09:33:40 Voltage Offset Correction: v_off_ini = -108.202 uV, v_off_fin = -116.059 uV 09:33:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.613 uVs 09:33:40 Integrated Voltage Measurement... 09:33:49 Voltage Offset Correction: v_off_ini = -92.363 uV, v_off_fin = -103.186 uV 09:33:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.336 uVs 09:33:49 Integrated Voltage Measurement... 09:33:58 Voltage Offset Correction: v_off_ini = -103.550 uV, v_off_fin = -104.202 uV 09:33:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.552 uVs 09:33:58 Integrated Voltage Measurement... 09:34:07 Voltage Offset Correction: v_off_ini = -86.310 uV, v_off_fin = -90.143 uV 09:34:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.040 uVs 09:34:11 I1X Average and RMS of Measurements VT = -88.416 +- 3.362 uVs I1X = 17.684 +- 0.673 uTm 09:34:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:34:18 Integrated Voltage Measurement... 09:34:27 Voltage Offset Correction: v_off_ini = -118.095 uV, v_off_fin = -135.494 uV 09:34:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.106 uVs 09:34:27 Integrated Voltage Measurement... 09:34:36 Voltage Offset Correction: v_off_ini = -115.673 uV, v_off_fin = -104.272 uV 09:34:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.761 uVs 09:34:36 Integrated Voltage Measurement... 09:34:45 Voltage Offset Correction: v_off_ini = -120.639 uV, v_off_fin = -124.446 uV 09:34:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.704 uVs 09:34:45 Integrated Voltage Measurement... 09:34:54 Voltage Offset Correction: v_off_ini = -121.890 uV, v_off_fin = -112.157 uV 09:34:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.450 uVs 09:34:54 Integrated Voltage Measurement... 09:35:03 Voltage Offset Correction: v_off_ini = -130.738 uV, v_off_fin = -144.018 uV 09:35:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.360 uVs 09:35:03 Integrated Voltage Measurement... 09:35:12 Voltage Offset Correction: v_off_ini = -129.855 uV, v_off_fin = -109.057 uV 09:35:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.498 uVs 09:35:16 I1Y Average and RMS of Measurements VT = -224.480 +- 1.692 uVs I1Y = -44.893 +- 0.337 uTm 09:35:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:35:24 Integrated Voltage Measurement... 09:35:33 Voltage Offset Correction: v_off_ini = -135.372 uV, v_off_fin = -141.076 uV 09:35:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.708 uVs 09:35:33 Integrated Voltage Measurement... 09:35:42 Voltage Offset Correction: v_off_ini = -122.422 uV, v_off_fin = -109.433 uV 09:35:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 113.860 uVs 09:35:42 Integrated Voltage Measurement... 09:35:51 Voltage Offset Correction: v_off_ini = -121.989 uV, v_off_fin = -123.982 uV 09:35:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.790 uVs 09:35:51 Integrated Voltage Measurement... 09:36:00 Voltage Offset Correction: v_off_ini = -123.946 uV, v_off_fin = -123.386 uV 09:36:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.856 uVs 09:36:00 Integrated Voltage Measurement... 09:36:09 Voltage Offset Correction: v_off_ini = -142.219 uV, v_off_fin = -136.712 uV 09:36:09 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -87.555 uVs 09:36:09 Integrated Voltage Measurement... 09:36:18 Voltage Offset Correction: v_off_ini = -134.847 uV, v_off_fin = -117.787 uV 09:36:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 117.143 uVs 09:36:20 I2X Average and RMS of Measurements VT = -101.486 +- 10.820 uVs I2X = 9.337 +- 0.995 uTm^2 09:36:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:36:28 Integrated Voltage Measurement... 09:36:37 Voltage Offset Correction: v_off_ini = -127.722 uV, v_off_fin = -119.501 uV 09:36:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.501 uVs 09:36:37 Integrated Voltage Measurement... 09:36:46 Voltage Offset Correction: v_off_ini = -124.160 uV, v_off_fin = -103.286 uV 09:36:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.924 uVs 09:36:46 Integrated Voltage Measurement... 09:36:55 Voltage Offset Correction: v_off_ini = -113.016 uV, v_off_fin = -126.818 uV 09:36:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.431 uVs 09:36:55 Integrated Voltage Measurement... 09:37:04 Voltage Offset Correction: v_off_ini = -132.349 uV, v_off_fin = -139.626 uV 09:37:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.235 uVs 09:37:05 Integrated Voltage Measurement... 09:37:14 Voltage Offset Correction: v_off_ini = -131.699 uV, v_off_fin = -129.994 uV 09:37:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.506 uVs 09:37:14 Integrated Voltage Measurement... 09:37:23 Voltage Offset Correction: v_off_ini = -137.424 uV, v_off_fin = -114.566 uV 09:37:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.548 uVs 09:37:25 I2Y Average and RMS of Measurements VT = -254.524 +- 5.448 uVs I2Y = -23.416 +- 0.501 uTm^2 09:37:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:37:43 Integrated Voltage Measurement... 09:37:52 Voltage Offset Correction: v_off_ini = -128.034 uV, v_off_fin = -142.198 uV 09:37:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.736 uVs 09:37:52 Integrated Voltage Measurement... 09:38:01 Voltage Offset Correction: v_off_ini = -149.403 uV, v_off_fin = -128.154 uV 09:38:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.506 uVs 09:38:01 Integrated Voltage Measurement... 09:38:10 Voltage Offset Correction: v_off_ini = -124.072 uV, v_off_fin = -119.265 uV 09:38:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.740 uVs 09:38:10 Integrated Voltage Measurement... 09:38:19 Voltage Offset Correction: v_off_ini = -118.525 uV, v_off_fin = -120.407 uV 09:38:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.008 uVs 09:38:20 Integrated Voltage Measurement... 09:38:28 Voltage Offset Correction: v_off_ini = -118.788 uV, v_off_fin = -125.923 uV 09:38:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.927 uVs 09:38:29 Integrated Voltage Measurement... 09:38:37 Voltage Offset Correction: v_off_ini = -126.687 uV, v_off_fin = -127.143 uV 09:38:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.364 uVs 09:38:42 I1X Average and RMS of Measurements VT = -93.214 +- 4.211 uVs I1X = 18.643 +- 0.842 uTm 09:38:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:38:48 Integrated Voltage Measurement... 09:38:57 Voltage Offset Correction: v_off_ini = -117.985 uV, v_off_fin = -122.990 uV 09:38:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.873 uVs 09:38:57 Integrated Voltage Measurement... 09:39:06 Voltage Offset Correction: v_off_ini = -116.683 uV, v_off_fin = -106.883 uV 09:39:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.726 uVs 09:39:06 Integrated Voltage Measurement... 09:39:15 Voltage Offset Correction: v_off_ini = -119.253 uV, v_off_fin = -114.165 uV 09:39:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.123 uVs 09:39:15 Integrated Voltage Measurement... 09:39:24 Voltage Offset Correction: v_off_ini = -116.475 uV, v_off_fin = -103.913 uV 09:39:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.523 uVs 09:39:24 Integrated Voltage Measurement... 09:39:33 Voltage Offset Correction: v_off_ini = -131.632 uV, v_off_fin = -139.597 uV 09:39:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.630 uVs 09:39:33 Integrated Voltage Measurement... 09:39:42 Voltage Offset Correction: v_off_ini = -138.664 uV, v_off_fin = -126.535 uV 09:39:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 223.747 uVs 09:39:47 I1Y Average and RMS of Measurements VT = -228.437 +- 4.860 uVs I1Y = -45.684 +- 0.976 uTm 09:39:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:39:54 Integrated Voltage Measurement... 09:40:03 Voltage Offset Correction: v_off_ini = -131.157 uV, v_off_fin = -150.040 uV 09:40:03 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -117.542 uVs 09:40:03 Integrated Voltage Measurement... 09:40:12 Voltage Offset Correction: v_off_ini = -122.189 uV, v_off_fin = -113.312 uV 09:40:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.718 uVs 09:40:12 Integrated Voltage Measurement... 09:40:21 Voltage Offset Correction: v_off_ini = -127.155 uV, v_off_fin = -136.249 uV 09:40:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.489 uVs 09:40:21 Integrated Voltage Measurement... 09:40:30 Voltage Offset Correction: v_off_ini = -121.555 uV, v_off_fin = -116.128 uV 09:40:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.581 uVs 09:40:31 Integrated Voltage Measurement... 09:40:40 Voltage Offset Correction: v_off_ini = -128.561 uV, v_off_fin = -132.610 uV 09:40:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.521 uVs 09:40:40 Integrated Voltage Measurement... 09:40:49 Voltage Offset Correction: v_off_ini = -135.464 uV, v_off_fin = -108.805 uV 09:40:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.309 uVs 09:40:51 I2X Average and RMS of Measurements VT = -106.193 +- 4.611 uVs I2X = 9.770 +- 0.424 uTm^2 09:40:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:40:59 Integrated Voltage Measurement... 09:41:08 Voltage Offset Correction: v_off_ini = -134.216 uV, v_off_fin = -137.367 uV 09:41:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.254 uVs 09:41:08 Integrated Voltage Measurement... 09:41:17 Voltage Offset Correction: v_off_ini = -133.415 uV, v_off_fin = -127.389 uV 09:41:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.563 uVs 09:41:17 Integrated Voltage Measurement... 09:41:26 Voltage Offset Correction: v_off_ini = -129.685 uV, v_off_fin = -128.528 uV 09:41:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.447 uVs 09:41:26 Integrated Voltage Measurement... 09:41:35 Voltage Offset Correction: v_off_ini = -126.899 uV, v_off_fin = -138.122 uV 09:41:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.476 uVs 09:41:35 Integrated Voltage Measurement... 09:41:44 Voltage Offset Correction: v_off_ini = -142.222 uV, v_off_fin = -157.784 uV 09:41:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.645 uVs 09:41:44 Integrated Voltage Measurement... 09:41:53 Voltage Offset Correction: v_off_ini = -144.090 uV, v_off_fin = -150.619 uV 09:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.298 uVs 09:41:55 I2Y Average and RMS of Measurements VT = -240.280 +- 12.411 uVs I2Y = -22.106 +- 1.142 uTm^2 09:42:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:42:13 Integrated Voltage Measurement... 09:42:22 Voltage Offset Correction: v_off_ini = -150.454 uV, v_off_fin = -146.400 uV 09:42:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.432 uVs 09:42:22 Integrated Voltage Measurement... 09:42:31 Voltage Offset Correction: v_off_ini = -148.748 uV, v_off_fin = -142.972 uV 09:42:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.419 uVs 09:42:32 Integrated Voltage Measurement... 09:42:40 Voltage Offset Correction: v_off_ini = -156.768 uV, v_off_fin = -148.542 uV 09:42:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.138 uVs 09:42:41 Integrated Voltage Measurement... 09:42:49 Voltage Offset Correction: v_off_ini = -137.525 uV, v_off_fin = -144.727 uV 09:42:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.591 uVs 09:42:50 Integrated Voltage Measurement... 09:42:58 Voltage Offset Correction: v_off_ini = -124.717 uV, v_off_fin = -132.272 uV 09:42:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.030 uVs 09:42:59 Integrated Voltage Measurement... 09:43:08 Voltage Offset Correction: v_off_ini = -95.492 uV, v_off_fin = -94.065 uV 09:43:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.929 uVs 09:43:12 I1X Average and RMS of Measurements VT = -93.090 +- 7.679 uVs I1X = 18.618 +- 1.536 uTm 09:43:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:43:19 Integrated Voltage Measurement... 09:43:28 Voltage Offset Correction: v_off_ini = -106.538 uV, v_off_fin = -137.106 uV 09:43:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.680 uVs 09:43:28 Integrated Voltage Measurement... 09:43:37 Voltage Offset Correction: v_off_ini = -123.514 uV, v_off_fin = -108.532 uV 09:43:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 258.348 uVs 09:43:37 Integrated Voltage Measurement... 09:43:46 Voltage Offset Correction: v_off_ini = -125.622 uV, v_off_fin = -140.308 uV 09:43:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -228.298 uVs 09:43:46 Integrated Voltage Measurement... 09:43:55 Voltage Offset Correction: v_off_ini = -140.911 uV, v_off_fin = -109.445 uV 09:43:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 232.165 uVs 09:43:55 Integrated Voltage Measurement... 09:44:04 Voltage Offset Correction: v_off_ini = -121.523 uV, v_off_fin = -139.546 uV 09:44:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -229.425 uVs 09:44:04 Integrated Voltage Measurement... 09:44:13 Voltage Offset Correction: v_off_ini = -116.323 uV, v_off_fin = -108.496 uV 09:44:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.590 uVs 09:44:17 I1Y Average and RMS of Measurements VT = -231.084 +- 4.534 uVs I1Y = -46.209 +- 0.907 uTm 09:44:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:44:25 Integrated Voltage Measurement... 09:44:34 Voltage Offset Correction: v_off_ini = -118.804 uV, v_off_fin = -130.859 uV 09:44:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -119.305 uVs 09:44:34 Integrated Voltage Measurement... 09:44:43 Voltage Offset Correction: v_off_ini = -114.465 uV, v_off_fin = -102.182 uV 09:44:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.616 uVs 09:44:43 Integrated Voltage Measurement... 09:44:52 Voltage Offset Correction: v_off_ini = -120.337 uV, v_off_fin = -135.307 uV 09:44:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.678 uVs 09:44:52 Integrated Voltage Measurement... 09:45:01 Voltage Offset Correction: v_off_ini = -114.679 uV, v_off_fin = -106.891 uV 09:45:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.480 uVs 09:45:01 Integrated Voltage Measurement... 09:45:10 Voltage Offset Correction: v_off_ini = -113.319 uV, v_off_fin = -121.948 uV 09:45:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.293 uVs 09:45:10 Integrated Voltage Measurement... 09:45:19 Voltage Offset Correction: v_off_ini = -135.796 uV, v_off_fin = -114.784 uV 09:45:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.140 uVs 09:45:21 I2X Average and RMS of Measurements VT = -101.919 +- 12.374 uVs I2X = 9.377 +- 1.138 uTm^2 09:45:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:45:29 Integrated Voltage Measurement... 09:45:38 Voltage Offset Correction: v_off_ini = -131.471 uV, v_off_fin = -128.904 uV 09:45:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.245 uVs 09:45:38 Integrated Voltage Measurement... 09:45:47 Voltage Offset Correction: v_off_ini = -128.671 uV, v_off_fin = -131.031 uV 09:45:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.321 uVs 09:45:47 Integrated Voltage Measurement... 09:45:56 Voltage Offset Correction: v_off_ini = -124.871 uV, v_off_fin = -132.161 uV 09:45:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.674 uVs 09:45:56 Integrated Voltage Measurement... 09:46:05 Voltage Offset Correction: v_off_ini = -128.531 uV, v_off_fin = -119.844 uV 09:46:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.811 uVs 09:46:05 Integrated Voltage Measurement... 09:46:14 Voltage Offset Correction: v_off_ini = -115.212 uV, v_off_fin = -115.960 uV 09:46:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.912 uVs 09:46:14 Integrated Voltage Measurement... 09:46:23 Voltage Offset Correction: v_off_ini = -124.546 uV, v_off_fin = -133.779 uV 09:46:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.407 uVs 09:46:26 I2Y Average and RMS of Measurements VT = -243.728 +- 3.943 uVs I2Y = -22.423 +- 0.363 uTm^2 09:46:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:46:44 Integrated Voltage Measurement... 09:46:53 Voltage Offset Correction: v_off_ini = -118.201 uV, v_off_fin = -142.693 uV 09:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.634 uVs 09:46:53 Integrated Voltage Measurement... 09:47:02 Voltage Offset Correction: v_off_ini = -134.134 uV, v_off_fin = -139.332 uV 09:47:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.689 uVs 09:47:02 Integrated Voltage Measurement... 09:47:11 Voltage Offset Correction: v_off_ini = -132.318 uV, v_off_fin = -127.011 uV 09:47:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.276 uVs 09:47:11 Integrated Voltage Measurement... 09:47:20 Voltage Offset Correction: v_off_ini = -123.885 uV, v_off_fin = -110.735 uV 09:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.889 uVs 09:47:20 Integrated Voltage Measurement... 09:47:29 Voltage Offset Correction: v_off_ini = -100.996 uV, v_off_fin = -108.572 uV 09:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.766 uVs 09:47:29 Integrated Voltage Measurement... 09:47:38 Voltage Offset Correction: v_off_ini = -118.137 uV, v_off_fin = -121.054 uV 09:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.310 uVs 09:47:42 I1X Average and RMS of Measurements VT = -101.094 +- 3.496 uVs I1X = 20.219 +- 0.699 uTm 09:47:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:47:49 Integrated Voltage Measurement... 09:47:58 Voltage Offset Correction: v_off_ini = -132.427 uV, v_off_fin = -137.493 uV 09:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.163 uVs 09:47:58 Integrated Voltage Measurement... 09:48:07 Voltage Offset Correction: v_off_ini = -120.293 uV, v_off_fin = -103.168 uV 09:48:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 249.663 uVs 09:48:07 Integrated Voltage Measurement... 09:48:16 Voltage Offset Correction: v_off_ini = -115.613 uV, v_off_fin = -127.720 uV 09:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -239.623 uVs 09:48:16 Integrated Voltage Measurement... 09:48:25 Voltage Offset Correction: v_off_ini = -126.331 uV, v_off_fin = -95.012 uV 09:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 231.678 uVs 09:48:25 Integrated Voltage Measurement... 09:48:34 Voltage Offset Correction: v_off_ini = -111.923 uV, v_off_fin = -119.101 uV 09:48:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -240.121 uVs 09:48:34 Integrated Voltage Measurement... 09:48:43 Voltage Offset Correction: v_off_ini = -106.855 uV, v_off_fin = -103.640 uV 09:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 246.290 uVs 09:48:47 I1Y Average and RMS of Measurements VT = -236.590 +- 5.062 uVs I1Y = -47.310 +- 1.011 uTm 09:48:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:48:55 Integrated Voltage Measurement... 09:49:04 Voltage Offset Correction: v_off_ini = -111.234 uV, v_off_fin = -118.281 uV 09:49:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -107.177 uVs 09:49:04 Integrated Voltage Measurement... 09:49:13 Voltage Offset Correction: v_off_ini = -114.684 uV, v_off_fin = -122.626 uV 09:49:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.993 uVs 09:49:13 Integrated Voltage Measurement... 09:49:22 Voltage Offset Correction: v_off_ini = -129.481 uV, v_off_fin = -127.519 uV 09:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.096 uVs 09:49:22 Integrated Voltage Measurement... 09:49:31 Voltage Offset Correction: v_off_ini = -127.767 uV, v_off_fin = -120.077 uV 09:49:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.447 uVs 09:49:31 Integrated Voltage Measurement... 09:49:40 Voltage Offset Correction: v_off_ini = -121.975 uV, v_off_fin = -125.659 uV 09:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.183 uVs 09:49:40 Integrated Voltage Measurement... 09:49:49 Voltage Offset Correction: v_off_ini = -130.353 uV, v_off_fin = -122.519 uV 09:49:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.816 uVs 09:49:52 I2X Average and RMS of Measurements VT = -99.952 +- 5.006 uVs I2X = 9.196 +- 0.460 uTm^2 09:49:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:49:59 Integrated Voltage Measurement... 09:50:08 Voltage Offset Correction: v_off_ini = -129.355 uV, v_off_fin = -119.252 uV 09:50:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.275 uVs 09:50:08 Integrated Voltage Measurement... 09:50:17 Voltage Offset Correction: v_off_ini = -120.289 uV, v_off_fin = -116.909 uV 09:50:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.737 uVs 09:50:18 Integrated Voltage Measurement... 09:50:27 Voltage Offset Correction: v_off_ini = -133.871 uV, v_off_fin = -133.047 uV 09:50:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.028 uVs 09:50:27 Integrated Voltage Measurement... 09:50:36 Voltage Offset Correction: v_off_ini = -125.547 uV, v_off_fin = -118.916 uV 09:50:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.383 uVs 09:50:36 Integrated Voltage Measurement... 09:50:45 Voltage Offset Correction: v_off_ini = -117.412 uV, v_off_fin = -116.410 uV 09:50:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.642 uVs 09:50:45 Integrated Voltage Measurement... 09:50:54 Voltage Offset Correction: v_off_ini = -128.908 uV, v_off_fin = -115.218 uV 09:50:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.321 uVs 09:50:56 I2Y Average and RMS of Measurements VT = -249.398 +- 11.749 uVs I2Y = -22.945 +- 1.081 uTm^2 09:51:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:51:14 Integrated Voltage Measurement... 09:51:23 Voltage Offset Correction: v_off_ini = -108.358 uV, v_off_fin = -116.430 uV 09:51:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.400 uVs 09:51:23 Integrated Voltage Measurement... 09:51:32 Voltage Offset Correction: v_off_ini = -106.564 uV, v_off_fin = -103.926 uV 09:51:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.406 uVs 09:51:33 Integrated Voltage Measurement... 09:51:41 Voltage Offset Correction: v_off_ini = -110.471 uV, v_off_fin = -113.628 uV 09:51:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.375 uVs 09:51:42 Integrated Voltage Measurement... 09:51:51 Voltage Offset Correction: v_off_ini = -104.754 uV, v_off_fin = -94.748 uV 09:51:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.472 uVs 09:51:51 Integrated Voltage Measurement... 09:52:00 Voltage Offset Correction: v_off_ini = -104.660 uV, v_off_fin = -105.763 uV 09:52:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.660 uVs 09:52:00 Integrated Voltage Measurement... 09:52:09 Voltage Offset Correction: v_off_ini = -105.330 uV, v_off_fin = -106.318 uV 09:52:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.887 uVs 09:52:13 I1X Average and RMS of Measurements VT = -101.867 +- 4.387 uVs I1X = 20.374 +- 0.878 uTm 09:52:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:52:20 Integrated Voltage Measurement... 09:52:29 Voltage Offset Correction: v_off_ini = -117.071 uV, v_off_fin = -126.795 uV 09:52:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -229.870 uVs 09:52:29 Integrated Voltage Measurement... 09:52:38 Voltage Offset Correction: v_off_ini = -111.580 uV, v_off_fin = -105.702 uV 09:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.539 uVs 09:52:38 Integrated Voltage Measurement... 09:52:47 Voltage Offset Correction: v_off_ini = -109.153 uV, v_off_fin = -121.070 uV 09:52:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -241.571 uVs 09:52:47 Integrated Voltage Measurement... 09:52:56 Voltage Offset Correction: v_off_ini = -105.321 uV, v_off_fin = -89.193 uV 09:52:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.806 uVs 09:52:56 Integrated Voltage Measurement... 09:53:05 Voltage Offset Correction: v_off_ini = -92.733 uV, v_off_fin = -110.054 uV 09:53:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.185 uVs 09:53:05 Integrated Voltage Measurement... 09:53:14 Voltage Offset Correction: v_off_ini = -97.915 uV, v_off_fin = -92.865 uV 09:53:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.369 uVs 09:53:18 I1Y Average and RMS of Measurements VT = -233.057 +- 3.590 uVs I1Y = -46.607 +- 0.716 uTm 09:53:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:53:26 Integrated Voltage Measurement... 09:53:35 Voltage Offset Correction: v_off_ini = -105.567 uV, v_off_fin = -120.328 uV 09:53:35 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -94.511 uVs 09:53:35 Integrated Voltage Measurement... 09:53:44 Voltage Offset Correction: v_off_ini = -100.837 uV, v_off_fin = -81.745 uV 09:53:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.877 uVs 09:53:44 Integrated Voltage Measurement... 09:53:53 Voltage Offset Correction: v_off_ini = -108.696 uV, v_off_fin = -102.412 uV 09:53:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.505 uVs 09:53:53 Integrated Voltage Measurement... 09:54:02 Voltage Offset Correction: v_off_ini = -94.469 uV, v_off_fin = -93.839 uV 09:54:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.646 uVs 09:54:02 Integrated Voltage Measurement... 09:54:11 Voltage Offset Correction: v_off_ini = -99.628 uV, v_off_fin = -112.671 uV 09:54:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.672 uVs 09:54:11 Integrated Voltage Measurement... 09:54:20 Voltage Offset Correction: v_off_ini = -103.994 uV, v_off_fin = -98.452 uV 09:54:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.309 uVs 09:54:22 I2X Average and RMS of Measurements VT = -98.587 +- 7.805 uVs I2X = 9.070 +- 0.718 uTm^2 09:54:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:54:30 Integrated Voltage Measurement... 09:54:39 Voltage Offset Correction: v_off_ini = -99.505 uV, v_off_fin = -98.685 uV 09:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.604 uVs 09:54:39 Integrated Voltage Measurement... 09:54:48 Voltage Offset Correction: v_off_ini = -109.655 uV, v_off_fin = -101.613 uV 09:54:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.817 uVs 09:54:48 Integrated Voltage Measurement... 09:54:57 Voltage Offset Correction: v_off_ini = -99.912 uV, v_off_fin = -92.153 uV 09:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.159 uVs 09:54:57 Integrated Voltage Measurement... 09:55:06 Voltage Offset Correction: v_off_ini = -95.598 uV, v_off_fin = -93.070 uV 09:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.723 uVs 09:55:06 Integrated Voltage Measurement... 09:55:15 Voltage Offset Correction: v_off_ini = -86.115 uV, v_off_fin = -99.723 uV 09:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.245 uVs 09:55:15 Integrated Voltage Measurement... 09:55:24 Voltage Offset Correction: v_off_ini = -107.513 uV, v_off_fin = -96.496 uV 09:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.850 uVs 09:55:27 I2Y Average and RMS of Measurements VT = -247.067 +- 4.990 uVs I2Y = -22.730 +- 0.459 uTm^2 09:55:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm