SLAC Magnetic Measurements Date: 10-20-2025 Time: 16:02:36 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16347 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 16:02:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:46 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:02:48 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:02:49 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:02:51 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:03:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:13 Integrated Voltage Measurement... 16:03:22 Voltage Offset Correction: v_off_ini = 157.784 uV, v_off_fin = 152.131 uV 16:03:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.619 uVs 16:03:22 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = 151.181 uV, v_off_fin = 165.756 uV 16:03:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.514 uVs 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = 136.925 uV, v_off_fin = 135.988 uV 16:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.700 uVs 16:03:40 Integrated Voltage Measurement... 16:03:49 Voltage Offset Correction: v_off_ini = 146.826 uV, v_off_fin = 145.648 uV 16:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.420 uVs 16:03:49 Integrated Voltage Measurement... 16:03:58 Voltage Offset Correction: v_off_ini = 142.897 uV, v_off_fin = 137.953 uV 16:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.603 uVs 16:03:58 Integrated Voltage Measurement... 16:04:07 Voltage Offset Correction: v_off_ini = 139.022 uV, v_off_fin = 147.491 uV 16:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.116 uVs 16:04:12 I1X Average and RMS of Measurements VT = -102.329 +- 7.915 uVs I1X = 20.466 +- 1.583 uTm 16:04:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:18 Integrated Voltage Measurement... 16:04:27 Voltage Offset Correction: v_off_ini = 155.423 uV, v_off_fin = 147.972 uV 16:04:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -187.541 uVs 16:04:27 Integrated Voltage Measurement... 16:04:36 Voltage Offset Correction: v_off_ini = 149.834 uV, v_off_fin = 156.956 uV 16:04:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.293 uVs 16:04:36 Integrated Voltage Measurement... 16:04:45 Voltage Offset Correction: v_off_ini = 160.780 uV, v_off_fin = 145.382 uV 16:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.323 uVs 16:04:45 Integrated Voltage Measurement... 16:04:54 Voltage Offset Correction: v_off_ini = 145.885 uV, v_off_fin = 153.519 uV 16:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.969 uVs 16:04:54 Integrated Voltage Measurement... 16:05:03 Voltage Offset Correction: v_off_ini = 157.784 uV, v_off_fin = 143.738 uV 16:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.269 uVs 16:05:03 Integrated Voltage Measurement... 16:05:12 Voltage Offset Correction: v_off_ini = 154.161 uV, v_off_fin = 152.272 uV 16:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.303 uVs 16:05:17 I1Y Average and RMS of Measurements VT = -187.616 +- 2.726 uVs I1Y = -37.524 +- 0.546 uTm 16:05:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:24 Integrated Voltage Measurement... 16:05:33 Voltage Offset Correction: v_off_ini = 153.214 uV, v_off_fin = 140.019 uV 16:05:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.748 uVs 16:05:33 Integrated Voltage Measurement... 16:05:42 Voltage Offset Correction: v_off_ini = 154.766 uV, v_off_fin = 160.679 uV 16:05:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.096 uVs 16:05:42 Integrated Voltage Measurement... 16:05:51 Voltage Offset Correction: v_off_ini = 134.961 uV, v_off_fin = 131.691 uV 16:05:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.295 uVs 16:05:51 Integrated Voltage Measurement... 16:06:00 Voltage Offset Correction: v_off_ini = 151.456 uV, v_off_fin = 156.467 uV 16:06:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.212 uVs 16:06:01 Integrated Voltage Measurement... 16:06:09 Voltage Offset Correction: v_off_ini = 147.301 uV, v_off_fin = 143.745 uV 16:06:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.270 uVs 16:06:10 Integrated Voltage Measurement... 16:06:19 Voltage Offset Correction: v_off_ini = 160.603 uV, v_off_fin = 154.602 uV 16:06:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.109 uVs 16:06:21 I2X Average and RMS of Measurements VT = -134.288 +- 4.870 uVs I2X = 12.355 +- 0.448 uTm^2 16:06:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:29 Integrated Voltage Measurement... 16:06:38 Voltage Offset Correction: v_off_ini = 147.258 uV, v_off_fin = 135.483 uV 16:06:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.854 uVs 16:06:38 Integrated Voltage Measurement... 16:06:47 Voltage Offset Correction: v_off_ini = 142.246 uV, v_off_fin = 146.540 uV 16:06:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.124 uVs 16:06:47 Integrated Voltage Measurement... 16:06:56 Voltage Offset Correction: v_off_ini = 157.051 uV, v_off_fin = 153.717 uV 16:06:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.414 uVs 16:06:56 Integrated Voltage Measurement... 16:07:05 Voltage Offset Correction: v_off_ini = 151.235 uV, v_off_fin = 145.199 uV 16:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.209 uVs 16:07:05 Integrated Voltage Measurement... 16:07:14 Voltage Offset Correction: v_off_ini = 144.175 uV, v_off_fin = 138.301 uV 16:07:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.761 uVs 16:07:14 Integrated Voltage Measurement... 16:07:23 Voltage Offset Correction: v_off_ini = 145.536 uV, v_off_fin = 152.437 uV 16:07:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.359 uVs 16:07:25 I2Y Average and RMS of Measurements VT = -223.287 +- 8.691 uVs I2Y = -20.542 +- 0.800 uTm^2 16:07:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:40 Integrated Voltage Measurement... 16:07:49 Voltage Offset Correction: v_off_ini = 143.217 uV, v_off_fin = 146.400 uV 16:07:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.044 uVs 16:07:49 Integrated Voltage Measurement... 16:07:58 Voltage Offset Correction: v_off_ini = 161.561 uV, v_off_fin = 146.251 uV 16:07:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.036 uVs 16:07:58 Integrated Voltage Measurement... 16:08:07 Voltage Offset Correction: v_off_ini = 129.216 uV, v_off_fin = 138.889 uV 16:08:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.093 uVs 16:08:07 Integrated Voltage Measurement... 16:08:16 Voltage Offset Correction: v_off_ini = 144.464 uV, v_off_fin = 149.857 uV 16:08:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.766 uVs 16:08:16 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = 146.726 uV, v_off_fin = 132.158 uV 16:08:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.289 uVs 16:08:26 Integrated Voltage Measurement... 16:08:34 Voltage Offset Correction: v_off_ini = 132.177 uV, v_off_fin = 135.018 uV 16:08:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.773 uVs 16:08:39 I1X Average and RMS of Measurements VT = -97.667 +- 13.098 uVs I1X = 19.533 +- 2.620 uTm 16:08:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:46 Integrated Voltage Measurement... 16:08:54 Voltage Offset Correction: v_off_ini = 144.598 uV, v_off_fin = 143.972 uV 16:08:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.657 uVs 16:08:55 Integrated Voltage Measurement... 16:09:03 Voltage Offset Correction: v_off_ini = 148.043 uV, v_off_fin = 158.276 uV 16:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.069 uVs 16:09:04 Integrated Voltage Measurement... 16:09:12 Voltage Offset Correction: v_off_ini = 149.186 uV, v_off_fin = 140.214 uV 16:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.349 uVs 16:09:13 Integrated Voltage Measurement... 16:09:21 Voltage Offset Correction: v_off_ini = 142.490 uV, v_off_fin = 158.933 uV 16:09:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.079 uVs 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 140.236 uV, v_off_fin = 143.617 uV 16:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.694 uVs 16:09:31 Integrated Voltage Measurement... 16:09:39 Voltage Offset Correction: v_off_ini = 139.578 uV, v_off_fin = 164.599 uV 16:09:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.786 uVs 16:09:44 I1Y Average and RMS of Measurements VT = -206.439 +- 4.137 uVs I1Y = -41.288 +- 0.827 uTm 16:09:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:51 Integrated Voltage Measurement... 16:10:00 Voltage Offset Correction: v_off_ini = 153.840 uV, v_off_fin = 142.192 uV 16:10:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.102 uVs 16:10:01 Integrated Voltage Measurement... 16:10:10 Voltage Offset Correction: v_off_ini = 133.676 uV, v_off_fin = 151.968 uV 16:10:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.014 uVs 16:10:10 Integrated Voltage Measurement... 16:10:19 Voltage Offset Correction: v_off_ini = 137.533 uV, v_off_fin = 129.666 uV 16:10:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.334 uVs 16:10:19 Integrated Voltage Measurement... 16:10:28 Voltage Offset Correction: v_off_ini = 140.489 uV, v_off_fin = 145.990 uV 16:10:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.375 uVs 16:10:28 Integrated Voltage Measurement... 16:10:37 Voltage Offset Correction: v_off_ini = 131.120 uV, v_off_fin = 129.010 uV 16:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.985 uVs 16:10:37 Integrated Voltage Measurement... 16:10:46 Voltage Offset Correction: v_off_ini = 125.562 uV, v_off_fin = 159.168 uV 16:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.221 uVs 16:10:48 I2X Average and RMS of Measurements VT = -127.505 +- 4.202 uVs I2X = 11.731 +- 0.387 uTm^2 16:10:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:56 Integrated Voltage Measurement... 16:11:05 Voltage Offset Correction: v_off_ini = 144.882 uV, v_off_fin = 149.929 uV 16:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.060 uVs 16:11:05 Integrated Voltage Measurement... 16:11:14 Voltage Offset Correction: v_off_ini = 140.438 uV, v_off_fin = 143.878 uV 16:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.919 uVs 16:11:14 Integrated Voltage Measurement... 16:11:23 Voltage Offset Correction: v_off_ini = 140.816 uV, v_off_fin = 136.434 uV 16:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.155 uVs 16:11:23 Integrated Voltage Measurement... 16:11:32 Voltage Offset Correction: v_off_ini = 145.628 uV, v_off_fin = 144.119 uV 16:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.796 uVs 16:11:32 Integrated Voltage Measurement... 16:11:41 Voltage Offset Correction: v_off_ini = 138.246 uV, v_off_fin = 145.409 uV 16:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.600 uVs 16:11:41 Integrated Voltage Measurement... 16:11:50 Voltage Offset Correction: v_off_ini = 138.613 uV, v_off_fin = 142.901 uV 16:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.110 uVs 16:11:53 I2Y Average and RMS of Measurements VT = -250.106 +- 4.704 uVs I2Y = -23.010 +- 0.433 uTm^2 16:12:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:08 Integrated Voltage Measurement... 16:12:17 Voltage Offset Correction: v_off_ini = 122.947 uV, v_off_fin = 121.966 uV 16:12:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.697 uVs 16:12:17 Integrated Voltage Measurement... 16:12:26 Voltage Offset Correction: v_off_ini = 127.457 uV, v_off_fin = 135.627 uV 16:12:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.046 uVs 16:12:26 Integrated Voltage Measurement... 16:12:35 Voltage Offset Correction: v_off_ini = 139.552 uV, v_off_fin = 124.699 uV 16:12:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.418 uVs 16:12:35 Integrated Voltage Measurement... 16:12:44 Voltage Offset Correction: v_off_ini = 122.615 uV, v_off_fin = 118.900 uV 16:12:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.640 uVs 16:12:44 Integrated Voltage Measurement... 16:12:53 Voltage Offset Correction: v_off_ini = 119.002 uV, v_off_fin = 113.637 uV 16:12:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.274 uVs 16:12:53 Integrated Voltage Measurement... 16:13:02 Voltage Offset Correction: v_off_ini = 129.020 uV, v_off_fin = 118.684 uV 16:13:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.838 uVs 16:13:06 I1X Average and RMS of Measurements VT = -92.652 +- 5.885 uVs I1X = 18.530 +- 1.177 uTm 16:13:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:13 Integrated Voltage Measurement... 16:13:22 Voltage Offset Correction: v_off_ini = 125.928 uV, v_off_fin = 122.440 uV 16:13:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.306 uVs 16:13:22 Integrated Voltage Measurement... 16:13:31 Voltage Offset Correction: v_off_ini = 118.490 uV, v_off_fin = 127.321 uV 16:13:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.373 uVs 16:13:31 Integrated Voltage Measurement... 16:13:40 Voltage Offset Correction: v_off_ini = 123.711 uV, v_off_fin = 98.358 uV 16:13:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.117 uVs 16:13:40 Integrated Voltage Measurement... 16:13:49 Voltage Offset Correction: v_off_ini = 125.456 uV, v_off_fin = 142.020 uV 16:13:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.925 uVs 16:13:49 Integrated Voltage Measurement... 16:13:58 Voltage Offset Correction: v_off_ini = 130.582 uV, v_off_fin = 121.551 uV 16:13:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.773 uVs 16:13:58 Integrated Voltage Measurement... 16:14:07 Voltage Offset Correction: v_off_ini = 137.035 uV, v_off_fin = 143.912 uV 16:14:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.776 uVs 16:14:11 I1Y Average and RMS of Measurements VT = -220.545 +- 0.371 uVs I1Y = -44.109 +- 0.074 uTm 16:14:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:19 Integrated Voltage Measurement... 16:14:28 Voltage Offset Correction: v_off_ini = 118.554 uV, v_off_fin = 118.569 uV 16:14:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.162 uVs 16:14:28 Integrated Voltage Measurement... 16:14:37 Voltage Offset Correction: v_off_ini = 121.228 uV, v_off_fin = 149.511 uV 16:14:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.598 uVs 16:14:37 Integrated Voltage Measurement... 16:14:46 Voltage Offset Correction: v_off_ini = 131.107 uV, v_off_fin = 133.871 uV 16:14:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.714 uVs 16:14:46 Integrated Voltage Measurement... 16:14:55 Voltage Offset Correction: v_off_ini = 146.880 uV, v_off_fin = 143.968 uV 16:14:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.957 uVs 16:14:55 Integrated Voltage Measurement... 16:15:04 Voltage Offset Correction: v_off_ini = 130.041 uV, v_off_fin = 122.765 uV 16:15:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.028 uVs 16:15:04 Integrated Voltage Measurement... 16:15:13 Voltage Offset Correction: v_off_ini = 111.496 uV, v_off_fin = 140.314 uV 16:15:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.549 uVs 16:15:15 I2X Average and RMS of Measurements VT = -131.501 +- 5.433 uVs I2X = 12.098 +- 0.500 uTm^2 16:15:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:23 Integrated Voltage Measurement... 16:15:32 Voltage Offset Correction: v_off_ini = 127.099 uV, v_off_fin = 117.089 uV 16:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.154 uVs 16:15:32 Integrated Voltage Measurement... 16:15:41 Voltage Offset Correction: v_off_ini = 130.566 uV, v_off_fin = 127.129 uV 16:15:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.341 uVs 16:15:41 Integrated Voltage Measurement... 16:15:50 Voltage Offset Correction: v_off_ini = 135.315 uV, v_off_fin = 129.163 uV 16:15:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.077 uVs 16:15:50 Integrated Voltage Measurement... 16:15:59 Voltage Offset Correction: v_off_ini = 132.312 uV, v_off_fin = 129.494 uV 16:15:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.037 uVs 16:15:59 Integrated Voltage Measurement... 16:16:08 Voltage Offset Correction: v_off_ini = 124.546 uV, v_off_fin = 125.078 uV 16:16:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.685 uVs 16:16:08 Integrated Voltage Measurement... 16:16:17 Voltage Offset Correction: v_off_ini = 135.279 uV, v_off_fin = 134.257 uV 16:16:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.820 uVs 16:16:20 I2Y Average and RMS of Measurements VT = -258.519 +- 10.228 uVs I2Y = -23.784 +- 0.941 uTm^2 16:16:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:35 Integrated Voltage Measurement... 16:16:44 Voltage Offset Correction: v_off_ini = 127.419 uV, v_off_fin = 108.089 uV 16:16:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.680 uVs 16:16:44 Integrated Voltage Measurement... 16:16:53 Voltage Offset Correction: v_off_ini = 113.481 uV, v_off_fin = 132.394 uV 16:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.737 uVs 16:16:53 Integrated Voltage Measurement... 16:17:02 Voltage Offset Correction: v_off_ini = 134.598 uV, v_off_fin = 117.411 uV 16:17:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.501 uVs 16:17:02 Integrated Voltage Measurement... 16:17:11 Voltage Offset Correction: v_off_ini = 117.469 uV, v_off_fin = 120.479 uV 16:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.869 uVs 16:17:11 Integrated Voltage Measurement... 16:17:20 Voltage Offset Correction: v_off_ini = 118.028 uV, v_off_fin = 111.956 uV 16:17:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.106 uVs 16:17:20 Integrated Voltage Measurement... 16:17:29 Voltage Offset Correction: v_off_ini = 109.370 uV, v_off_fin = 106.334 uV 16:17:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.624 uVs 16:17:33 I1X Average and RMS of Measurements VT = -101.253 +- 7.994 uVs I1X = 20.251 +- 1.599 uTm 16:17:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:40 Integrated Voltage Measurement... 16:17:49 Voltage Offset Correction: v_off_ini = 104.709 uV, v_off_fin = 95.570 uV 16:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.233 uVs 16:17:49 Integrated Voltage Measurement... 16:17:58 Voltage Offset Correction: v_off_ini = 106.407 uV, v_off_fin = 119.181 uV 16:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.639 uVs 16:17:58 Integrated Voltage Measurement... 16:18:07 Voltage Offset Correction: v_off_ini = 100.913 uV, v_off_fin = 84.301 uV 16:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.607 uVs 16:18:07 Integrated Voltage Measurement... 16:18:16 Voltage Offset Correction: v_off_ini = 111.130 uV, v_off_fin = 121.348 uV 16:18:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.836 uVs 16:18:16 Integrated Voltage Measurement... 16:18:25 Voltage Offset Correction: v_off_ini = 113.004 uV, v_off_fin = 101.469 uV 16:18:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.897 uVs 16:18:25 Integrated Voltage Measurement... 16:18:34 Voltage Offset Correction: v_off_ini = 94.394 uV, v_off_fin = 104.001 uV 16:18:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.822 uVs 16:18:38 I1Y Average and RMS of Measurements VT = -230.006 +- 3.789 uVs I1Y = -46.001 +- 0.758 uTm 16:18:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:46 Integrated Voltage Measurement... 16:18:55 Voltage Offset Correction: v_off_ini = 97.144 uV, v_off_fin = 86.103 uV 16:18:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -124.399 uVs 16:18:55 Integrated Voltage Measurement... 16:19:04 Voltage Offset Correction: v_off_ini = 84.903 uV, v_off_fin = 99.804 uV 16:19:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.954 uVs 16:19:04 Integrated Voltage Measurement... 16:19:13 Voltage Offset Correction: v_off_ini = 88.240 uV, v_off_fin = 80.094 uV 16:19:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.504 uVs 16:19:13 Integrated Voltage Measurement... 16:19:22 Voltage Offset Correction: v_off_ini = 83.510 uV, v_off_fin = 87.134 uV 16:19:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.548 uVs 16:19:22 Integrated Voltage Measurement... 16:19:31 Voltage Offset Correction: v_off_ini = 83.764 uV, v_off_fin = 68.167 uV 16:19:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.797 uVs 16:19:31 Integrated Voltage Measurement... 16:19:40 Voltage Offset Correction: v_off_ini = 78.904 uV, v_off_fin = 93.309 uV 16:19:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.360 uVs 16:19:43 I2X Average and RMS of Measurements VT = -124.260 +- 4.522 uVs I2X = 11.432 +- 0.416 uTm^2 16:19:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:50 Integrated Voltage Measurement... 16:19:59 Voltage Offset Correction: v_off_ini = 76.805 uV, v_off_fin = 87.561 uV 16:19:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.523 uVs 16:19:59 Integrated Voltage Measurement... 16:20:08 Voltage Offset Correction: v_off_ini = 85.366 uV, v_off_fin = 89.694 uV 16:20:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.459 uVs 16:20:09 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = 96.113 uV, v_off_fin = 94.213 uV 16:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.602 uVs 16:20:18 Integrated Voltage Measurement... 16:20:27 Voltage Offset Correction: v_off_ini = 94.566 uV, v_off_fin = 88.016 uV 16:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.701 uVs 16:20:27 Integrated Voltage Measurement... 16:20:36 Voltage Offset Correction: v_off_ini = 94.248 uV, v_off_fin = 94.353 uV 16:20:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.774 uVs 16:20:36 Integrated Voltage Measurement... 16:20:45 Voltage Offset Correction: v_off_ini = 101.269 uV, v_off_fin = 108.052 uV 16:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.472 uVs 16:20:47 I2Y Average and RMS of Measurements VT = -280.755 +- 7.519 uVs I2Y = -25.829 +- 0.692 uTm^2 16:20:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:02 Integrated Voltage Measurement... 16:21:11 Voltage Offset Correction: v_off_ini = 104.249 uV, v_off_fin = 93.032 uV 16:21:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.071 uVs 16:21:11 Integrated Voltage Measurement... 16:21:20 Voltage Offset Correction: v_off_ini = 106.870 uV, v_off_fin = 93.829 uV 16:21:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.062 uVs 16:21:20 Integrated Voltage Measurement... 16:21:29 Voltage Offset Correction: v_off_ini = 81.057 uV, v_off_fin = 84.360 uV 16:21:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.617 uVs 16:21:29 Integrated Voltage Measurement... 16:21:38 Voltage Offset Correction: v_off_ini = 90.281 uV, v_off_fin = 99.980 uV 16:21:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.819 uVs 16:21:38 Integrated Voltage Measurement... 16:21:47 Voltage Offset Correction: v_off_ini = 102.814 uV, v_off_fin = 80.975 uV 16:21:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.143 uVs 16:21:47 Integrated Voltage Measurement... 16:21:56 Voltage Offset Correction: v_off_ini = 98.648 uV, v_off_fin = 90.174 uV 16:21:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.678 uVs 16:22:00 I1X Average and RMS of Measurements VT = -81.065 +- 6.734 uVs I1X = 16.213 +- 1.347 uTm 16:22:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:07 Integrated Voltage Measurement... 16:22:16 Voltage Offset Correction: v_off_ini = 80.762 uV, v_off_fin = 80.894 uV 16:22:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.691 uVs 16:22:16 Integrated Voltage Measurement... 16:22:25 Voltage Offset Correction: v_off_ini = 95.381 uV, v_off_fin = 105.805 uV 16:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.159 uVs 16:22:25 Integrated Voltage Measurement... 16:22:34 Voltage Offset Correction: v_off_ini = 100.263 uV, v_off_fin = 96.181 uV 16:22:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -247.366 uVs 16:22:34 Integrated Voltage Measurement... 16:22:43 Voltage Offset Correction: v_off_ini = 86.401 uV, v_off_fin = 95.200 uV 16:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.734 uVs 16:22:43 Integrated Voltage Measurement... 16:22:52 Voltage Offset Correction: v_off_ini = 88.738 uV, v_off_fin = 89.616 uV 16:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.379 uVs 16:22:52 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = 100.647 uV, v_off_fin = 101.626 uV 16:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.564 uVs 16:23:06 I1Y Average and RMS of Measurements VT = -246.982 +- 4.275 uVs I1Y = -49.393 +- 0.853 uTm 16:23:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:13 Integrated Voltage Measurement... 16:23:22 Voltage Offset Correction: v_off_ini = 70.240 uV, v_off_fin = 80.949 uV 16:23:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.428 uVs 16:23:22 Integrated Voltage Measurement... 16:23:31 Voltage Offset Correction: v_off_ini = 86.994 uV, v_off_fin = 107.717 uV 16:23:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.837 uVs 16:23:31 Integrated Voltage Measurement... 16:23:40 Voltage Offset Correction: v_off_ini = 97.408 uV, v_off_fin = 91.632 uV 16:23:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.515 uVs 16:23:40 Integrated Voltage Measurement... 16:23:49 Voltage Offset Correction: v_off_ini = 88.819 uV, v_off_fin = 97.078 uV 16:23:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.259 uVs 16:23:50 Integrated Voltage Measurement... 16:23:59 Voltage Offset Correction: v_off_ini = 84.154 uV, v_off_fin = 76.353 uV 16:23:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.217 uVs 16:23:59 Integrated Voltage Measurement... 16:24:08 Voltage Offset Correction: v_off_ini = 78.893 uV, v_off_fin = 96.812 uV 16:24:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.852 uVs 16:24:10 I2X Average and RMS of Measurements VT = -118.185 +- 5.068 uVs I2X = 10.873 +- 0.467 uTm^2 16:24:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:18 Integrated Voltage Measurement... 16:24:27 Voltage Offset Correction: v_off_ini = 83.564 uV, v_off_fin = 90.476 uV 16:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.423 uVs 16:24:27 Integrated Voltage Measurement... 16:24:36 Voltage Offset Correction: v_off_ini = 93.166 uV, v_off_fin = 101.685 uV 16:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.551 uVs 16:24:36 Integrated Voltage Measurement... 16:24:45 Voltage Offset Correction: v_off_ini = 101.905 uV, v_off_fin = 109.339 uV 16:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.193 uVs 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = 99.735 uV, v_off_fin = 96.398 uV 16:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.132 uVs 16:24:54 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 100.424 uV, v_off_fin = 101.216 uV 16:25:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.269 uVs 16:25:03 Integrated Voltage Measurement... 16:25:12 Voltage Offset Correction: v_off_ini = 101.929 uV, v_off_fin = 96.198 uV 16:25:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.345 uVs 16:25:14 I2Y Average and RMS of Measurements VT = -288.819 +- 4.584 uVs I2Y = -26.571 +- 0.422 uTm^2 16:25:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:29 Integrated Voltage Measurement... 16:25:38 Voltage Offset Correction: v_off_ini = 94.852 uV, v_off_fin = 92.836 uV 16:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.786 uVs 16:25:38 Integrated Voltage Measurement... 16:25:47 Voltage Offset Correction: v_off_ini = 93.540 uV, v_off_fin = 106.980 uV 16:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.496 uVs 16:25:47 Integrated Voltage Measurement... 16:25:56 Voltage Offset Correction: v_off_ini = 97.816 uV, v_off_fin = 86.484 uV 16:25:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.156 uVs 16:25:56 Integrated Voltage Measurement... 16:26:05 Voltage Offset Correction: v_off_ini = 96.834 uV, v_off_fin = 108.658 uV 16:26:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.157 uVs 16:26:05 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = 117.181 uV, v_off_fin = 98.955 uV 16:26:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.016 uVs 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = 104.742 uV, v_off_fin = 105.916 uV 16:26:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.850 uVs 16:26:28 I1X Average and RMS of Measurements VT = -89.077 +- 15.233 uVs I1X = 17.815 +- 3.047 uTm 16:26:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:34 Integrated Voltage Measurement... 16:26:43 Voltage Offset Correction: v_off_ini = 99.930 uV, v_off_fin = 93.639 uV 16:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -241.189 uVs 16:26:43 Integrated Voltage Measurement... 16:26:52 Voltage Offset Correction: v_off_ini = 99.007 uV, v_off_fin = 123.806 uV 16:26:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.111 uVs 16:26:52 Integrated Voltage Measurement... 16:27:01 Voltage Offset Correction: v_off_ini = 104.833 uV, v_off_fin = 95.505 uV 16:27:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -248.683 uVs 16:27:01 Integrated Voltage Measurement... 16:27:10 Voltage Offset Correction: v_off_ini = 110.673 uV, v_off_fin = 123.891 uV 16:27:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 249.418 uVs 16:27:10 Integrated Voltage Measurement... 16:27:19 Voltage Offset Correction: v_off_ini = 102.732 uV, v_off_fin = 106.686 uV 16:27:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.773 uVs 16:27:19 Integrated Voltage Measurement... 16:27:28 Voltage Offset Correction: v_off_ini = 123.829 uV, v_off_fin = 144.676 uV 16:27:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.699 uVs 16:27:33 I1Y Average and RMS of Measurements VT = -249.146 +- 0.448 uVs I1Y = -49.824 +- 0.090 uTm 16:27:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:40 Integrated Voltage Measurement... 16:27:49 Voltage Offset Correction: v_off_ini = 142.196 uV, v_off_fin = 137.041 uV 16:27:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -113.543 uVs 16:27:50 Integrated Voltage Measurement... 16:27:58 Voltage Offset Correction: v_off_ini = 163.151 uV, v_off_fin = 164.762 uV 16:27:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.024 uVs 16:27:59 Integrated Voltage Measurement... 16:28:08 Voltage Offset Correction: v_off_ini = 158.601 uV, v_off_fin = 148.939 uV 16:28:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.943 uVs 16:28:08 Integrated Voltage Measurement... 16:28:17 Voltage Offset Correction: v_off_ini = 156.051 uV, v_off_fin = 162.653 uV 16:28:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.809 uVs 16:28:17 Integrated Voltage Measurement... 16:28:26 Voltage Offset Correction: v_off_ini = 142.163 uV, v_off_fin = 142.694 uV 16:28:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.837 uVs 16:28:26 Integrated Voltage Measurement... 16:28:35 Voltage Offset Correction: v_off_ini = 147.586 uV, v_off_fin = 153.697 uV 16:28:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 113.160 uVs 16:28:37 I2X Average and RMS of Measurements VT = -116.886 +- 1.714 uVs I2X = 10.754 +- 0.157 uTm^2 16:28:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:45 Integrated Voltage Measurement... 16:28:54 Voltage Offset Correction: v_off_ini = 161.371 uV, v_off_fin = 154.816 uV 16:28:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.023 uVs 16:28:54 Integrated Voltage Measurement... 16:29:03 Voltage Offset Correction: v_off_ini = 148.716 uV, v_off_fin = 175.219 uV 16:29:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.021 uVs 16:29:03 Integrated Voltage Measurement... 16:29:12 Voltage Offset Correction: v_off_ini = 166.416 uV, v_off_fin = 160.105 uV 16:29:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.184 uVs 16:29:12 Integrated Voltage Measurement... 16:29:21 Voltage Offset Correction: v_off_ini = 156.739 uV, v_off_fin = 157.422 uV 16:29:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.302 uVs 16:29:21 Integrated Voltage Measurement... 16:29:30 Voltage Offset Correction: v_off_ini = 159.312 uV, v_off_fin = 161.912 uV 16:29:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.198 uVs 16:29:30 Integrated Voltage Measurement... 16:29:39 Voltage Offset Correction: v_off_ini = 156.737 uV, v_off_fin = 172.878 uV 16:29:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.576 uVs 16:29:42 I2Y Average and RMS of Measurements VT = -295.217 +- 6.503 uVs I2Y = -27.160 +- 0.598 uTm^2 16:29:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:56 Integrated Voltage Measurement... 16:30:05 Voltage Offset Correction: v_off_ini = 171.849 uV, v_off_fin = 161.893 uV 16:30:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.183 uVs 16:30:06 Integrated Voltage Measurement... 16:30:14 Voltage Offset Correction: v_off_ini = 164.260 uV, v_off_fin = 177.475 uV 16:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.975 uVs 16:30:15 Integrated Voltage Measurement... 16:30:24 Voltage Offset Correction: v_off_ini = 180.348 uV, v_off_fin = 163.911 uV 16:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.775 uVs 16:30:24 Integrated Voltage Measurement... 16:30:33 Voltage Offset Correction: v_off_ini = 175.909 uV, v_off_fin = 173.249 uV 16:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.639 uVs 16:30:33 Integrated Voltage Measurement... 16:30:42 Voltage Offset Correction: v_off_ini = 179.365 uV, v_off_fin = 159.276 uV 16:30:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.302 uVs 16:30:42 Integrated Voltage Measurement... 16:30:51 Voltage Offset Correction: v_off_ini = 153.004 uV, v_off_fin = 159.405 uV 16:30:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.305 uVs 16:30:55 I1X Average and RMS of Measurements VT = -78.863 +- 6.442 uVs I1X = 15.773 +- 1.288 uTm 16:30:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:02 Integrated Voltage Measurement... 16:31:11 Voltage Offset Correction: v_off_ini = 156.133 uV, v_off_fin = 143.871 uV 16:31:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.340 uVs 16:31:11 Integrated Voltage Measurement... 16:31:20 Voltage Offset Correction: v_off_ini = 159.208 uV, v_off_fin = 166.941 uV 16:31:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 268.791 uVs 16:31:20 Integrated Voltage Measurement... 16:31:29 Voltage Offset Correction: v_off_ini = 163.286 uV, v_off_fin = 157.041 uV 16:31:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -264.841 uVs 16:31:29 Integrated Voltage Measurement... 16:31:38 Voltage Offset Correction: v_off_ini = 167.762 uV, v_off_fin = 183.000 uV 16:31:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 277.580 uVs 16:31:38 Integrated Voltage Measurement... 16:31:47 Voltage Offset Correction: v_off_ini = 165.244 uV, v_off_fin = 169.782 uV 16:31:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.696 uVs 16:31:47 Integrated Voltage Measurement... 16:31:56 Voltage Offset Correction: v_off_ini = 181.309 uV, v_off_fin = 197.807 uV 16:31:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.186 uVs 16:32:00 I1Y Average and RMS of Measurements VT = -265.739 +- 7.286 uVs I1Y = -53.143 +- 1.458 uTm 16:32:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 184.672 uV, v_off_fin = 176.062 uV 16:32:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.297 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 182.054 uV, v_off_fin = 184.457 uV 16:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.998 uVs 16:32:26 Integrated Voltage Measurement... 16:32:35 Voltage Offset Correction: v_off_ini = 183.969 uV, v_off_fin = 172.763 uV 16:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.640 uVs 16:32:35 Integrated Voltage Measurement... 16:32:44 Voltage Offset Correction: v_off_ini = 177.930 uV, v_off_fin = 194.204 uV 16:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.765 uVs 16:32:44 Integrated Voltage Measurement... 16:32:53 Voltage Offset Correction: v_off_ini = 169.469 uV, v_off_fin = 165.833 uV 16:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.218 uVs 16:32:53 Integrated Voltage Measurement... 16:33:02 Voltage Offset Correction: v_off_ini = 166.678 uV, v_off_fin = 168.273 uV 16:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.618 uVs 16:33:04 I2X Average and RMS of Measurements VT = -102.756 +- 8.020 uVs I2X = 9.453 +- 0.738 uTm^2 16:33:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:12 Integrated Voltage Measurement... 16:33:21 Voltage Offset Correction: v_off_ini = 153.403 uV, v_off_fin = 143.195 uV 16:33:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.160 uVs 16:33:21 Integrated Voltage Measurement... 16:33:30 Voltage Offset Correction: v_off_ini = 153.708 uV, v_off_fin = 183.946 uV 16:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.285 uVs 16:33:30 Integrated Voltage Measurement... 16:33:39 Voltage Offset Correction: v_off_ini = 178.283 uV, v_off_fin = 181.913 uV 16:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.641 uVs 16:33:39 Integrated Voltage Measurement... 16:33:48 Voltage Offset Correction: v_off_ini = 173.545 uV, v_off_fin = 167.835 uV 16:33:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.175 uVs 16:33:48 Integrated Voltage Measurement... 16:33:57 Voltage Offset Correction: v_off_ini = 171.005 uV, v_off_fin = 162.132 uV 16:33:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.114 uVs 16:33:57 Integrated Voltage Measurement... 16:34:06 Voltage Offset Correction: v_off_ini = 173.307 uV, v_off_fin = 189.634 uV 16:34:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.189 uVs 16:34:09 I2Y Average and RMS of Measurements VT = -301.927 +- 4.286 uVs I2Y = -27.777 +- 0.394 uTm^2 16:34:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:24 Integrated Voltage Measurement... 16:34:33 Voltage Offset Correction: v_off_ini = 196.899 uV, v_off_fin = 176.150 uV 16:34:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.865 uVs 16:34:33 Integrated Voltage Measurement... 16:34:42 Voltage Offset Correction: v_off_ini = 162.143 uV, v_off_fin = 180.232 uV 16:34:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.859 uVs 16:34:42 Integrated Voltage Measurement... 16:34:51 Voltage Offset Correction: v_off_ini = 165.215 uV, v_off_fin = 171.395 uV 16:34:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.543 uVs 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 167.676 uV, v_off_fin = 170.618 uV 16:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.080 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 197.673 uV, v_off_fin = 178.245 uV 16:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.191 uVs 16:35:09 Integrated Voltage Measurement... 16:35:18 Voltage Offset Correction: v_off_ini = 188.928 uV, v_off_fin = 177.379 uV 16:35:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.090 uVs 16:35:22 I1X Average and RMS of Measurements VT = -85.438 +- 6.460 uVs I1X = 17.088 +- 1.292 uTm 16:35:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:29 Integrated Voltage Measurement... 16:35:38 Voltage Offset Correction: v_off_ini = 169.748 uV, v_off_fin = 158.621 uV 16:35:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.266 uVs 16:35:38 Integrated Voltage Measurement... 16:35:47 Voltage Offset Correction: v_off_ini = 174.823 uV, v_off_fin = 190.956 uV 16:35:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.558 uVs 16:35:47 Integrated Voltage Measurement... 16:35:56 Voltage Offset Correction: v_off_ini = 189.769 uV, v_off_fin = 165.449 uV 16:35:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.054 uVs 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 180.797 uV, v_off_fin = 189.049 uV 16:36:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.060 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 176.940 uV, v_off_fin = 166.478 uV 16:36:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.597 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 184.761 uV, v_off_fin = 192.396 uV 16:36:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 273.498 uVs 16:36:27 I1Y Average and RMS of Measurements VT = -264.839 +- 2.259 uVs I1Y = -52.964 +- 0.454 uTm 16:36:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:35 Integrated Voltage Measurement... 16:36:44 Voltage Offset Correction: v_off_ini = 180.253 uV, v_off_fin = 184.395 uV 16:36:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.859 uVs 16:36:44 Integrated Voltage Measurement... 16:36:53 Voltage Offset Correction: v_off_ini = 180.239 uV, v_off_fin = 196.462 uV 16:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.298 uVs 16:36:53 Integrated Voltage Measurement... 16:37:02 Voltage Offset Correction: v_off_ini = 189.494 uV, v_off_fin = 178.584 uV 16:37:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.039 uVs 16:37:02 Integrated Voltage Measurement... 16:37:11 Voltage Offset Correction: v_off_ini = 182.270 uV, v_off_fin = 209.165 uV 16:37:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.307 uVs 16:37:11 Integrated Voltage Measurement... 16:37:20 Voltage Offset Correction: v_off_ini = 204.424 uV, v_off_fin = 184.888 uV 16:37:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.985 uVs 16:37:20 Integrated Voltage Measurement... 16:37:29 Voltage Offset Correction: v_off_ini = 195.953 uV, v_off_fin = 199.981 uV 16:37:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.923 uVs 16:37:31 I2X Average and RMS of Measurements VT = -107.902 +- 11.739 uVs I2X = 9.927 +- 1.080 uTm^2 16:37:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:39 Integrated Voltage Measurement... 16:37:48 Voltage Offset Correction: v_off_ini = 176.450 uV, v_off_fin = 174.963 uV 16:37:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.271 uVs 16:37:48 Integrated Voltage Measurement... 16:37:57 Voltage Offset Correction: v_off_ini = 166.411 uV, v_off_fin = 170.709 uV 16:37:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.585 uVs 16:37:57 Integrated Voltage Measurement... 16:38:06 Voltage Offset Correction: v_off_ini = 160.819 uV, v_off_fin = 166.553 uV 16:38:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.155 uVs 16:38:06 Integrated Voltage Measurement... 16:38:15 Voltage Offset Correction: v_off_ini = 159.522 uV, v_off_fin = 171.177 uV 16:38:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.875 uVs 16:38:15 Integrated Voltage Measurement... 16:38:24 Voltage Offset Correction: v_off_ini = 175.100 uV, v_off_fin = 164.614 uV 16:38:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.334 uVs 16:38:24 Integrated Voltage Measurement... 16:38:33 Voltage Offset Correction: v_off_ini = 168.696 uV, v_off_fin = 178.041 uV 16:38:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.955 uVs 16:38:36 I2Y Average and RMS of Measurements VT = -304.029 +- 8.308 uVs I2Y = -27.971 +- 0.764 uTm^2 16:38:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:51 Integrated Voltage Measurement... 16:39:00 Voltage Offset Correction: v_off_ini = 179.286 uV, v_off_fin = 179.531 uV 16:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.784 uVs 16:39:00 Integrated Voltage Measurement... 16:39:09 Voltage Offset Correction: v_off_ini = 186.937 uV, v_off_fin = 183.613 uV 16:39:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.977 uVs 16:39:09 Integrated Voltage Measurement... 16:39:18 Voltage Offset Correction: v_off_ini = 182.501 uV, v_off_fin = 174.840 uV 16:39:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.808 uVs 16:39:18 Integrated Voltage Measurement... 16:39:27 Voltage Offset Correction: v_off_ini = 187.743 uV, v_off_fin = 193.912 uV 16:39:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.858 uVs 16:39:27 Integrated Voltage Measurement... 16:39:36 Voltage Offset Correction: v_off_ini = 201.745 uV, v_off_fin = 186.950 uV 16:39:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.210 uVs 16:39:36 Integrated Voltage Measurement... 16:39:45 Voltage Offset Correction: v_off_ini = 207.542 uV, v_off_fin = 199.226 uV 16:39:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.817 uVs 16:39:49 I1X Average and RMS of Measurements VT = -76.242 +- 2.939 uVs I1X = 15.248 +- 0.588 uTm 16:39:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:56 Integrated Voltage Measurement... 16:40:05 Voltage Offset Correction: v_off_ini = 197.493 uV, v_off_fin = 187.521 uV 16:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -260.638 uVs 16:40:05 Integrated Voltage Measurement... 16:40:14 Voltage Offset Correction: v_off_ini = 194.236 uV, v_off_fin = 217.677 uV 16:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 273.259 uVs 16:40:14 Integrated Voltage Measurement... 16:40:23 Voltage Offset Correction: v_off_ini = 195.646 uV, v_off_fin = 179.032 uV 16:40:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.527 uVs 16:40:23 Integrated Voltage Measurement... 16:40:32 Voltage Offset Correction: v_off_ini = 176.739 uV, v_off_fin = 192.227 uV 16:40:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.699 uVs 16:40:32 Integrated Voltage Measurement... 16:40:41 Voltage Offset Correction: v_off_ini = 187.271 uV, v_off_fin = 178.938 uV 16:40:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.596 uVs 16:40:41 Integrated Voltage Measurement... 16:40:50 Voltage Offset Correction: v_off_ini = 189.239 uV, v_off_fin = 200.009 uV 16:40:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 281.721 uVs 16:40:54 I1Y Average and RMS of Measurements VT = -271.740 +- 3.415 uVs I1Y = -54.347 +- 0.682 uTm 16:40:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:02 Integrated Voltage Measurement... 16:41:11 Voltage Offset Correction: v_off_ini = 183.833 uV, v_off_fin = 171.779 uV 16:41:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.526 uVs 16:41:11 Integrated Voltage Measurement... 16:41:20 Voltage Offset Correction: v_off_ini = 180.620 uV, v_off_fin = 187.485 uV 16:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.591 uVs 16:41:20 Integrated Voltage Measurement... 16:41:29 Voltage Offset Correction: v_off_ini = 182.777 uV, v_off_fin = 180.944 uV 16:41:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.465 uVs 16:41:29 Integrated Voltage Measurement... 16:41:38 Voltage Offset Correction: v_off_ini = 191.102 uV, v_off_fin = 199.804 uV 16:41:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.001 uVs 16:41:38 Integrated Voltage Measurement... 16:41:47 Voltage Offset Correction: v_off_ini = 187.010 uV, v_off_fin = 182.798 uV 16:41:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.829 uVs 16:41:47 Integrated Voltage Measurement... 16:41:56 Voltage Offset Correction: v_off_ini = 197.722 uV, v_off_fin = 205.058 uV 16:41:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.545 uVs 16:41:59 I2X Average and RMS of Measurements VT = -103.993 +- 1.964 uVs I2X = 9.567 +- 0.181 uTm^2 16:42:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:06 Integrated Voltage Measurement... 16:42:15 Voltage Offset Correction: v_off_ini = 221.446 uV, v_off_fin = 217.486 uV 16:42:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -303.078 uVs 16:42:15 Integrated Voltage Measurement... 16:42:24 Voltage Offset Correction: v_off_ini = 205.753 uV, v_off_fin = 201.607 uV 16:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.966 uVs 16:42:24 Integrated Voltage Measurement... 16:42:33 Voltage Offset Correction: v_off_ini = 198.126 uV, v_off_fin = 192.918 uV 16:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.683 uVs 16:42:33 Integrated Voltage Measurement... 16:42:42 Voltage Offset Correction: v_off_ini = 185.743 uV, v_off_fin = 189.059 uV 16:42:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.300 uVs 16:42:42 Integrated Voltage Measurement... 16:42:51 Voltage Offset Correction: v_off_ini = 183.814 uV, v_off_fin = 177.494 uV 16:42:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.563 uVs 16:42:51 Integrated Voltage Measurement... 16:43:00 Voltage Offset Correction: v_off_ini = 175.078 uV, v_off_fin = 171.156 uV 16:43:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.627 uVs 16:43:03 I2Y Average and RMS of Measurements VT = -310.703 +- 2.098 uVs I2Y = -28.585 +- 0.194 uTm^2 16:43:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:18 Integrated Voltage Measurement... 16:43:27 Voltage Offset Correction: v_off_ini = 168.152 uV, v_off_fin = 171.467 uV 16:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.939 uVs 16:43:27 Integrated Voltage Measurement... 16:43:36 Voltage Offset Correction: v_off_ini = 172.531 uV, v_off_fin = 167.813 uV 16:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.155 uVs 16:43:36 Integrated Voltage Measurement... 16:43:45 Voltage Offset Correction: v_off_ini = 155.467 uV, v_off_fin = 164.453 uV 16:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.408 uVs 16:43:45 Integrated Voltage Measurement... 16:43:54 Voltage Offset Correction: v_off_ini = 174.691 uV, v_off_fin = 175.118 uV 16:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.804 uVs 16:43:54 Integrated Voltage Measurement... 16:44:03 Voltage Offset Correction: v_off_ini = 171.204 uV, v_off_fin = 159.319 uV 16:44:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.966 uVs 16:44:03 Integrated Voltage Measurement... 16:44:12 Voltage Offset Correction: v_off_ini = 165.783 uV, v_off_fin = 172.475 uV 16:44:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.587 uVs 16:44:16 I1X Average and RMS of Measurements VT = -79.643 +- 0.750 uVs I1X = 15.929 +- 0.150 uTm 16:44:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:23 Integrated Voltage Measurement... 16:44:32 Voltage Offset Correction: v_off_ini = 164.901 uV, v_off_fin = 155.526 uV 16:44:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.228 uVs 16:44:32 Integrated Voltage Measurement... 16:44:41 Voltage Offset Correction: v_off_ini = 170.481 uV, v_off_fin = 186.106 uV 16:44:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 284.687 uVs 16:44:41 Integrated Voltage Measurement... 16:44:50 Voltage Offset Correction: v_off_ini = 171.703 uV, v_off_fin = 170.423 uV 16:44:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.107 uVs 16:44:50 Integrated Voltage Measurement... 16:44:59 Voltage Offset Correction: v_off_ini = 169.165 uV, v_off_fin = 184.964 uV 16:44:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.791 uVs 16:44:59 Integrated Voltage Measurement... 16:45:08 Voltage Offset Correction: v_off_ini = 166.735 uV, v_off_fin = 157.639 uV 16:45:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.668 uVs 16:45:08 Integrated Voltage Measurement... 16:45:17 Voltage Offset Correction: v_off_ini = 156.355 uV, v_off_fin = 186.935 uV 16:45:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.596 uVs 16:45:21 I1Y Average and RMS of Measurements VT = -280.513 +- 3.217 uVs I1Y = -56.102 +- 0.642 uTm 16:45:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:29 Integrated Voltage Measurement... 16:45:38 Voltage Offset Correction: v_off_ini = 164.770 uV, v_off_fin = 175.470 uV 16:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.558 uVs 16:45:38 Integrated Voltage Measurement... 16:45:47 Voltage Offset Correction: v_off_ini = 189.269 uV, v_off_fin = 187.058 uV 16:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.806 uVs 16:45:47 Integrated Voltage Measurement... 16:45:56 Voltage Offset Correction: v_off_ini = 192.103 uV, v_off_fin = 175.818 uV 16:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.481 uVs 16:45:56 Integrated Voltage Measurement... 16:46:05 Voltage Offset Correction: v_off_ini = 158.163 uV, v_off_fin = 178.842 uV 16:46:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.973 uVs 16:46:05 Integrated Voltage Measurement... 16:46:14 Voltage Offset Correction: v_off_ini = 185.354 uV, v_off_fin = 178.369 uV 16:46:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.777 uVs 16:46:14 Integrated Voltage Measurement... 16:46:23 Voltage Offset Correction: v_off_ini = 189.474 uV, v_off_fin = 201.036 uV 16:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.581 uVs 16:46:26 I2X Average and RMS of Measurements VT = -98.196 +- 11.762 uVs I2X = 9.034 +- 1.082 uTm^2 16:46:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:33 Integrated Voltage Measurement... 16:46:42 Voltage Offset Correction: v_off_ini = 174.434 uV, v_off_fin = 170.129 uV 16:46:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.295 uVs 16:46:42 Integrated Voltage Measurement... 16:46:51 Voltage Offset Correction: v_off_ini = 183.217 uV, v_off_fin = 168.055 uV 16:46:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.317 uVs 16:46:51 Integrated Voltage Measurement... 16:47:00 Voltage Offset Correction: v_off_ini = 169.242 uV, v_off_fin = 173.317 uV 16:47:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.810 uVs 16:47:00 Integrated Voltage Measurement... 16:47:09 Voltage Offset Correction: v_off_ini = 185.000 uV, v_off_fin = 174.256 uV 16:47:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.758 uVs 16:47:10 Integrated Voltage Measurement... 16:47:18 Voltage Offset Correction: v_off_ini = 172.419 uV, v_off_fin = 175.322 uV 16:47:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.833 uVs 16:47:19 Integrated Voltage Measurement... 16:47:28 Voltage Offset Correction: v_off_ini = 168.211 uV, v_off_fin = 171.072 uV 16:47:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.202 uVs 16:47:30 I2Y Average and RMS of Measurements VT = -305.869 +- 13.736 uVs I2Y = -28.140 +- 1.264 uTm^2 16:47:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:45 Integrated Voltage Measurement... 16:47:54 Voltage Offset Correction: v_off_ini = 172.757 uV, v_off_fin = 166.773 uV 16:47:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.958 uVs 16:47:54 Integrated Voltage Measurement... 16:48:03 Voltage Offset Correction: v_off_ini = 168.696 uV, v_off_fin = 189.588 uV 16:48:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.555 uVs 16:48:03 Integrated Voltage Measurement... 16:48:12 Voltage Offset Correction: v_off_ini = 181.419 uV, v_off_fin = 183.716 uV 16:48:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.737 uVs 16:48:12 Integrated Voltage Measurement... 16:48:21 Voltage Offset Correction: v_off_ini = 193.890 uV, v_off_fin = 197.604 uV 16:48:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.237 uVs 16:48:21 Integrated Voltage Measurement... 16:48:30 Voltage Offset Correction: v_off_ini = 203.752 uV, v_off_fin = 206.608 uV 16:48:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.687 uVs 16:48:30 Integrated Voltage Measurement... 16:48:39 Voltage Offset Correction: v_off_ini = 219.382 uV, v_off_fin = 209.647 uV 16:48:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.149 uVs 16:48:43 I1X Average and RMS of Measurements VT = -74.887 +- 5.620 uVs I1X = 14.978 +- 1.124 uTm 16:48:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:50 Integrated Voltage Measurement... 16:48:59 Voltage Offset Correction: v_off_ini = 184.107 uV, v_off_fin = 177.588 uV 16:48:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -261.659 uVs 16:48:59 Integrated Voltage Measurement... 16:49:08 Voltage Offset Correction: v_off_ini = 202.088 uV, v_off_fin = 217.059 uV 16:49:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 283.725 uVs 16:49:08 Integrated Voltage Measurement... 16:49:17 Voltage Offset Correction: v_off_ini = 196.733 uV, v_off_fin = 183.888 uV 16:49:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.878 uVs 16:49:17 Integrated Voltage Measurement... 16:49:26 Voltage Offset Correction: v_off_ini = 196.379 uV, v_off_fin = 209.359 uV 16:49:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.373 uVs 16:49:26 Integrated Voltage Measurement... 16:49:35 Voltage Offset Correction: v_off_ini = 199.288 uV, v_off_fin = 185.428 uV 16:49:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.986 uVs 16:49:35 Integrated Voltage Measurement... 16:49:44 Voltage Offset Correction: v_off_ini = 221.319 uV, v_off_fin = 228.929 uV 16:49:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.587 uVs 16:49:48 I1Y Average and RMS of Measurements VT = -274.868 +- 3.124 uVs I1Y = -54.975 +- 0.624 uTm 16:49:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:56 Integrated Voltage Measurement... 16:50:05 Voltage Offset Correction: v_off_ini = 203.784 uV, v_off_fin = 193.797 uV 16:50:05 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.617 uVs 16:50:05 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = 201.137 uV, v_off_fin = 212.031 uV 16:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.539 uVs 16:50:14 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = 211.914 uV, v_off_fin = 190.594 uV 16:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.390 uVs 16:50:23 Integrated Voltage Measurement... 16:50:32 Voltage Offset Correction: v_off_ini = 196.347 uV, v_off_fin = 197.784 uV 16:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.325 uVs 16:50:32 Integrated Voltage Measurement... 16:50:41 Voltage Offset Correction: v_off_ini = 185.259 uV, v_off_fin = 171.172 uV 16:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.572 uVs 16:50:41 Integrated Voltage Measurement... 16:50:50 Voltage Offset Correction: v_off_ini = 183.658 uV, v_off_fin = 190.432 uV 16:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.212 uVs 16:50:52 I2X Average and RMS of Measurements VT = -92.109 +- 3.048 uVs I2X = 8.474 +- 0.280 uTm^2 16:50:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:00 Integrated Voltage Measurement... 16:51:09 Voltage Offset Correction: v_off_ini = 191.341 uV, v_off_fin = 188.608 uV 16:51:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.123 uVs 16:51:09 Integrated Voltage Measurement... 16:51:18 Voltage Offset Correction: v_off_ini = 186.362 uV, v_off_fin = 192.182 uV 16:51:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.517 uVs 16:51:18 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 194.249 uV, v_off_fin = 192.310 uV 16:51:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.264 uVs 16:51:27 Integrated Voltage Measurement... 16:51:36 Voltage Offset Correction: v_off_ini = 187.946 uV, v_off_fin = 188.239 uV 16:51:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.326 uVs 16:51:36 Integrated Voltage Measurement... 16:51:45 Voltage Offset Correction: v_off_ini = 182.564 uV, v_off_fin = 181.494 uV 16:51:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.322 uVs 16:51:45 Integrated Voltage Measurement... 16:51:54 Voltage Offset Correction: v_off_ini = 178.091 uV, v_off_fin = 185.101 uV 16:51:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.782 uVs 16:51:57 I2Y Average and RMS of Measurements VT = -310.889 +- 6.876 uVs I2Y = -28.602 +- 0.633 uTm^2 16:52:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:13 Integrated Voltage Measurement... 16:52:22 Voltage Offset Correction: v_off_ini = 179.496 uV, v_off_fin = 178.835 uV 16:52:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.217 uVs 16:52:22 Integrated Voltage Measurement... 16:52:31 Voltage Offset Correction: v_off_ini = 180.136 uV, v_off_fin = 191.898 uV 16:52:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.852 uVs 16:52:31 Integrated Voltage Measurement... 16:52:40 Voltage Offset Correction: v_off_ini = 182.434 uV, v_off_fin = 192.859 uV 16:52:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.942 uVs 16:52:40 Integrated Voltage Measurement... 16:52:49 Voltage Offset Correction: v_off_ini = 180.749 uV, v_off_fin = 188.585 uV 16:52:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.436 uVs 16:52:49 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = 176.634 uV, v_off_fin = 182.169 uV 16:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.284 uVs 16:52:58 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = 189.569 uV, v_off_fin = 186.212 uV 16:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.320 uVs 16:53:11 I1X Average and RMS of Measurements VT = -68.175 +- 6.381 uVs I1X = 13.635 +- 1.276 uTm 16:53:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:18 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = 189.283 uV, v_off_fin = 182.899 uV 16:53:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -281.122 uVs 16:53:27 Integrated Voltage Measurement... 16:53:36 Voltage Offset Correction: v_off_ini = 187.558 uV, v_off_fin = 209.828 uV 16:53:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 285.082 uVs 16:53:36 Integrated Voltage Measurement... 16:53:45 Voltage Offset Correction: v_off_ini = 195.580 uV, v_off_fin = 180.893 uV 16:53:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.434 uVs 16:53:45 Integrated Voltage Measurement... 16:53:54 Voltage Offset Correction: v_off_ini = 204.208 uV, v_off_fin = 215.599 uV 16:53:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.849 uVs 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = 185.420 uV, v_off_fin = 183.012 uV 16:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.640 uVs 16:54:03 Integrated Voltage Measurement... 16:54:12 Voltage Offset Correction: v_off_ini = 192.772 uV, v_off_fin = 213.685 uV 16:54:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.952 uVs 16:54:16 I1Y Average and RMS of Measurements VT = -280.347 +- 2.171 uVs I1Y = -56.067 +- 0.432 uTm 16:54:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:24 Integrated Voltage Measurement... 16:54:33 Voltage Offset Correction: v_off_ini = 194.906 uV, v_off_fin = 207.581 uV 16:54:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.358 uVs 16:54:33 Integrated Voltage Measurement... 16:54:42 Voltage Offset Correction: v_off_ini = 217.596 uV, v_off_fin = 220.117 uV 16:54:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.369 uVs 16:54:42 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = 226.499 uV, v_off_fin = 199.484 uV 16:54:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.219 uVs 16:54:51 Integrated Voltage Measurement... 16:55:00 Voltage Offset Correction: v_off_ini = 203.713 uV, v_off_fin = 225.332 uV 16:55:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.442 uVs 16:55:00 Integrated Voltage Measurement... 16:55:09 Voltage Offset Correction: v_off_ini = 210.958 uV, v_off_fin = 197.358 uV 16:55:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.747 uVs 16:55:09 Integrated Voltage Measurement... 16:55:18 Voltage Offset Correction: v_off_ini = 204.917 uV, v_off_fin = 239.175 uV 16:55:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.674 uVs 16:55:20 I2X Average and RMS of Measurements VT = -97.968 +- 10.447 uVs I2X = 9.013 +- 0.961 uTm^2 16:55:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:28 Integrated Voltage Measurement... 16:55:37 Voltage Offset Correction: v_off_ini = 225.124 uV, v_off_fin = 209.332 uV 16:55:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.357 uVs 16:55:37 Integrated Voltage Measurement... 16:55:46 Voltage Offset Correction: v_off_ini = 206.024 uV, v_off_fin = 214.208 uV 16:55:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.035 uVs 16:55:46 Integrated Voltage Measurement... 16:55:55 Voltage Offset Correction: v_off_ini = 219.678 uV, v_off_fin = 219.924 uV 16:55:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.084 uVs 16:55:55 Integrated Voltage Measurement... 16:56:04 Voltage Offset Correction: v_off_ini = 220.515 uV, v_off_fin = 242.103 uV 16:56:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.274 uVs 16:56:04 Integrated Voltage Measurement... 16:56:13 Voltage Offset Correction: v_off_ini = 234.046 uV, v_off_fin = 226.767 uV 16:56:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.561 uVs 16:56:13 Integrated Voltage Measurement... 16:56:22 Voltage Offset Correction: v_off_ini = 227.021 uV, v_off_fin = 218.998 uV 16:56:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.849 uVs 16:56:24 I2Y Average and RMS of Measurements VT = -308.527 +- 7.973 uVs I2Y = -28.384 +- 0.733 uTm^2 16:56:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:40 Integrated Voltage Measurement... 16:56:49 Voltage Offset Correction: v_off_ini = 226.940 uV, v_off_fin = 215.653 uV 16:56:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.261 uVs 16:56:50 Integrated Voltage Measurement... 16:56:58 Voltage Offset Correction: v_off_ini = 226.329 uV, v_off_fin = 221.291 uV 16:56:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.095 uVs 16:56:59 Integrated Voltage Measurement... 16:57:07 Voltage Offset Correction: v_off_ini = 215.493 uV, v_off_fin = 220.215 uV 16:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.315 uVs 16:57:08 Integrated Voltage Measurement... 16:57:16 Voltage Offset Correction: v_off_ini = 217.928 uV, v_off_fin = 211.862 uV 16:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.100 uVs 16:57:17 Integrated Voltage Measurement... 16:57:25 Voltage Offset Correction: v_off_ini = 196.534 uV, v_off_fin = 203.553 uV 16:57:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.634 uVs 16:57:26 Integrated Voltage Measurement... 16:57:35 Voltage Offset Correction: v_off_ini = 202.587 uV, v_off_fin = 221.718 uV 16:57:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.038 uVs 16:57:39 I1X Average and RMS of Measurements VT = -73.074 +- 2.811 uVs I1X = 14.615 +- 0.562 uTm 16:57:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:46 Integrated Voltage Measurement... 16:57:54 Voltage Offset Correction: v_off_ini = 206.350 uV, v_off_fin = 191.272 uV 16:57:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.607 uVs 16:57:55 Integrated Voltage Measurement... 16:58:03 Voltage Offset Correction: v_off_ini = 208.065 uV, v_off_fin = 219.252 uV 16:58:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 301.222 uVs 16:58:03 Integrated Voltage Measurement... 16:58:12 Voltage Offset Correction: v_off_ini = 207.994 uV, v_off_fin = 187.401 uV 16:58:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -286.209 uVs 16:58:12 Integrated Voltage Measurement... 16:58:21 Voltage Offset Correction: v_off_ini = 193.646 uV, v_off_fin = 211.340 uV 16:58:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 293.291 uVs 16:58:21 Integrated Voltage Measurement... 16:58:30 Voltage Offset Correction: v_off_ini = 195.835 uV, v_off_fin = 178.868 uV 16:58:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -301.376 uVs 16:58:30 Integrated Voltage Measurement... 16:58:39 Voltage Offset Correction: v_off_ini = 178.085 uV, v_off_fin = 196.864 uV 16:58:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 291.983 uVs 16:58:44 I1Y Average and RMS of Measurements VT = -292.615 +- 2.954 uVs I1Y = -58.517 +- 0.589 uTm 16:58:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:51 Integrated Voltage Measurement... 16:59:00 Voltage Offset Correction: v_off_ini = 191.152 uV, v_off_fin = 180.540 uV 16:59:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.154 uVs 16:59:00 Integrated Voltage Measurement... 16:59:09 Voltage Offset Correction: v_off_ini = 171.977 uV, v_off_fin = 185.093 uV 16:59:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.185 uVs 16:59:09 Integrated Voltage Measurement... 16:59:18 Voltage Offset Correction: v_off_ini = 180.489 uV, v_off_fin = 169.846 uV 16:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.116 uVs 16:59:18 Integrated Voltage Measurement... 16:59:27 Voltage Offset Correction: v_off_ini = 201.469 uV, v_off_fin = 219.236 uV 16:59:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.867 uVs 16:59:27 Integrated Voltage Measurement... 16:59:36 Voltage Offset Correction: v_off_ini = 230.478 uV, v_off_fin = 213.836 uV 16:59:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.876 uVs 16:59:37 Integrated Voltage Measurement... 16:59:45 Voltage Offset Correction: v_off_ini = 215.824 uV, v_off_fin = 218.151 uV 16:59:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.983 uVs 16:59:48 I2X Average and RMS of Measurements VT = -98.030 +- 6.311 uVs I2X = 9.019 +- 0.581 uTm^2 16:59:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:56 Integrated Voltage Measurement... 17:00:05 Voltage Offset Correction: v_off_ini = 224.874 uV, v_off_fin = 217.368 uV 17:00:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.256 uVs 17:00:05 Integrated Voltage Measurement... 17:00:14 Voltage Offset Correction: v_off_ini = 214.147 uV, v_off_fin = 198.342 uV 17:00:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.059 uVs 17:00:14 Integrated Voltage Measurement... 17:00:23 Voltage Offset Correction: v_off_ini = 190.100 uV, v_off_fin = 177.731 uV 17:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.412 uVs 17:00:23 Integrated Voltage Measurement... 17:00:32 Voltage Offset Correction: v_off_ini = 189.595 uV, v_off_fin = 189.256 uV 17:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.893 uVs 17:00:32 Integrated Voltage Measurement... 17:00:41 Voltage Offset Correction: v_off_ini = 172.894 uV, v_off_fin = 182.313 uV 17:00:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.343 uVs 17:00:41 Integrated Voltage Measurement... 17:00:50 Voltage Offset Correction: v_off_ini = 169.341 uV, v_off_fin = 175.586 uV 17:00:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.457 uVs 17:00:52 I2Y Average and RMS of Measurements VT = -320.237 +- 8.697 uVs I2Y = -29.462 +- 0.800 uTm^2 17:01:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:10 Integrated Voltage Measurement... 17:01:19 Voltage Offset Correction: v_off_ini = 180.075 uV, v_off_fin = 167.121 uV 17:01:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.324 uVs 17:01:19 Integrated Voltage Measurement... 17:01:28 Voltage Offset Correction: v_off_ini = 169.755 uV, v_off_fin = 180.496 uV 17:01:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.695 uVs 17:01:28 Integrated Voltage Measurement... 17:01:37 Voltage Offset Correction: v_off_ini = 172.710 uV, v_off_fin = 164.661 uV 17:01:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.374 uVs 17:01:37 Integrated Voltage Measurement... 17:01:46 Voltage Offset Correction: v_off_ini = 179.898 uV, v_off_fin = 172.190 uV 17:01:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.911 uVs 17:01:46 Integrated Voltage Measurement... 17:01:55 Voltage Offset Correction: v_off_ini = 161.195 uV, v_off_fin = 153.555 uV 17:01:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.061 uVs 17:01:55 Integrated Voltage Measurement... 17:02:04 Voltage Offset Correction: v_off_ini = 177.121 uV, v_off_fin = 166.332 uV 17:02:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.758 uVs 17:02:09 I1X Average and RMS of Measurements VT = -82.687 +- 4.644 uVs I1X = 16.538 +- 0.929 uTm 17:02:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:15 Integrated Voltage Measurement... 17:02:24 Voltage Offset Correction: v_off_ini = 165.220 uV, v_off_fin = 142.894 uV 17:02:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.474 uVs 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = 161.149 uV, v_off_fin = 182.381 uV 17:02:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 275.914 uVs 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = 164.704 uV, v_off_fin = 145.739 uV 17:02:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -296.000 uVs 17:02:42 Integrated Voltage Measurement... 17:02:51 Voltage Offset Correction: v_off_ini = 156.678 uV, v_off_fin = 170.657 uV 17:02:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 302.871 uVs 17:02:51 Integrated Voltage Measurement... 17:03:00 Voltage Offset Correction: v_off_ini = 164.602 uV, v_off_fin = 144.254 uV 17:03:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.421 uVs 17:03:00 Integrated Voltage Measurement... 17:03:09 Voltage Offset Correction: v_off_ini = 145.532 uV, v_off_fin = 148.488 uV 17:03:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 274.108 uVs 17:03:14 I1Y Average and RMS of Measurements VT = -280.798 +- 14.296 uVs I1Y = -56.156 +- 2.858 uTm 17:03:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:21 Integrated Voltage Measurement... 17:03:30 Voltage Offset Correction: v_off_ini = 132.805 uV, v_off_fin = 122.783 uV 17:03:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.967 uVs 17:03:30 Integrated Voltage Measurement... 17:03:39 Voltage Offset Correction: v_off_ini = 133.715 uV, v_off_fin = 143.454 uV 17:03:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.807 uVs 17:03:39 Integrated Voltage Measurement... 17:03:48 Voltage Offset Correction: v_off_ini = 137.289 uV, v_off_fin = 122.231 uV 17:03:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.246 uVs 17:03:48 Integrated Voltage Measurement... 17:03:57 Voltage Offset Correction: v_off_ini = 130.177 uV, v_off_fin = 153.086 uV 17:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.571 uVs 17:03:57 Integrated Voltage Measurement... 17:04:06 Voltage Offset Correction: v_off_ini = 130.088 uV, v_off_fin = 124.499 uV 17:04:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.329 uVs 17:04:07 Integrated Voltage Measurement... 17:04:16 Voltage Offset Correction: v_off_ini = 130.343 uV, v_off_fin = 151.968 uV 17:04:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.334 uVs 17:04:18 I2X Average and RMS of Measurements VT = -93.542 +- 3.041 uVs I2X = 8.606 +- 0.280 uTm^2 17:04:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:26 Integrated Voltage Measurement... 17:04:35 Voltage Offset Correction: v_off_ini = 134.481 uV, v_off_fin = 142.425 uV 17:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.567 uVs 17:04:35 Integrated Voltage Measurement... 17:04:44 Voltage Offset Correction: v_off_ini = 153.597 uV, v_off_fin = 158.411 uV 17:04:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.830 uVs 17:04:44 Integrated Voltage Measurement... 17:04:53 Voltage Offset Correction: v_off_ini = 161.647 uV, v_off_fin = 144.527 uV 17:04:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.255 uVs 17:04:53 Integrated Voltage Measurement... 17:05:02 Voltage Offset Correction: v_off_ini = 142.243 uV, v_off_fin = 137.639 uV 17:05:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.316 uVs 17:05:02 Integrated Voltage Measurement... 17:05:11 Voltage Offset Correction: v_off_ini = 134.562 uV, v_off_fin = 132.003 uV 17:05:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.711 uVs 17:05:11 Integrated Voltage Measurement... 17:05:20 Voltage Offset Correction: v_off_ini = 134.176 uV, v_off_fin = 138.308 uV 17:05:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.986 uVs 17:05:22 I2Y Average and RMS of Measurements VT = -306.444 +- 2.302 uVs I2Y = -28.193 +- 0.212 uTm^2 17:05:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:41 Integrated Voltage Measurement... 17:05:50 Voltage Offset Correction: v_off_ini = 150.212 uV, v_off_fin = 141.803 uV 17:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.889 uVs 17:05:50 Integrated Voltage Measurement... 17:05:59 Voltage Offset Correction: v_off_ini = 146.347 uV, v_off_fin = 156.260 uV 17:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.231 uVs 17:05:59 Integrated Voltage Measurement... 17:06:08 Voltage Offset Correction: v_off_ini = 136.838 uV, v_off_fin = 123.615 uV 17:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.175 uVs 17:06:08 Integrated Voltage Measurement... 17:06:17 Voltage Offset Correction: v_off_ini = 118.066 uV, v_off_fin = 122.184 uV 17:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.078 uVs 17:06:17 Integrated Voltage Measurement... 17:06:26 Voltage Offset Correction: v_off_ini = 134.229 uV, v_off_fin = 121.496 uV 17:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.010 uVs 17:06:26 Integrated Voltage Measurement... 17:06:35 Voltage Offset Correction: v_off_ini = 128.260 uV, v_off_fin = 124.180 uV 17:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.508 uVs 17:06:39 I1X Average and RMS of Measurements VT = -86.149 +- 3.755 uVs I1X = 17.230 +- 0.751 uTm 17:06:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:46 Integrated Voltage Measurement... 17:06:55 Voltage Offset Correction: v_off_ini = 114.638 uV, v_off_fin = 104.914 uV 17:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.925 uVs 17:06:55 Integrated Voltage Measurement... 17:07:04 Voltage Offset Correction: v_off_ini = 112.807 uV, v_off_fin = 125.280 uV 17:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 276.567 uVs 17:07:04 Integrated Voltage Measurement... 17:07:13 Voltage Offset Correction: v_off_ini = 119.019 uV, v_off_fin = 97.177 uV 17:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -287.456 uVs 17:07:13 Integrated Voltage Measurement... 17:07:22 Voltage Offset Correction: v_off_ini = 101.672 uV, v_off_fin = 122.126 uV 17:07:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 298.025 uVs 17:07:22 Integrated Voltage Measurement... 17:07:31 Voltage Offset Correction: v_off_ini = 116.145 uV, v_off_fin = 101.773 uV 17:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -276.374 uVs 17:07:31 Integrated Voltage Measurement... 17:07:40 Voltage Offset Correction: v_off_ini = 110.677 uV, v_off_fin = 121.065 uV 17:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 251.996 uVs 17:07:44 I1Y Average and RMS of Measurements VT = -276.390 +- 12.021 uVs I1Y = -55.273 +- 2.404 uTm 17:07:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:52 Integrated Voltage Measurement... 17:08:01 Voltage Offset Correction: v_off_ini = 107.817 uV, v_off_fin = 108.812 uV 17:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.168 uVs 17:08:01 Integrated Voltage Measurement... 17:08:10 Voltage Offset Correction: v_off_ini = 106.962 uV, v_off_fin = 118.822 uV 17:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.054 uVs 17:08:10 Integrated Voltage Measurement... 17:08:19 Voltage Offset Correction: v_off_ini = 103.501 uV, v_off_fin = 107.378 uV 17:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.519 uVs 17:08:19 Integrated Voltage Measurement... 17:08:28 Voltage Offset Correction: v_off_ini = 112.003 uV, v_off_fin = 124.231 uV 17:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.902 uVs 17:08:28 Integrated Voltage Measurement... 17:08:37 Voltage Offset Correction: v_off_ini = 107.450 uV, v_off_fin = 103.689 uV 17:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.167 uVs 17:08:37 Integrated Voltage Measurement... 17:08:46 Voltage Offset Correction: v_off_ini = 114.803 uV, v_off_fin = 128.550 uV 17:08:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.657 uVs 17:08:48 I2X Average and RMS of Measurements VT = -92.911 +- 6.093 uVs I2X = 8.548 +- 0.561 uTm^2 17:08:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:56 Integrated Voltage Measurement... 17:09:05 Voltage Offset Correction: v_off_ini = 113.025 uV, v_off_fin = 110.379 uV 17:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.311 uVs 17:09:05 Integrated Voltage Measurement... 17:09:14 Voltage Offset Correction: v_off_ini = 113.965 uV, v_off_fin = 113.559 uV 17:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.795 uVs 17:09:14 Integrated Voltage Measurement... 17:09:23 Voltage Offset Correction: v_off_ini = 127.049 uV, v_off_fin = 121.711 uV 17:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.548 uVs 17:09:23 Integrated Voltage Measurement... 17:09:32 Voltage Offset Correction: v_off_ini = 112.072 uV, v_off_fin = 102.110 uV 17:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.674 uVs 17:09:32 Integrated Voltage Measurement... 17:09:41 Voltage Offset Correction: v_off_ini = 100.328 uV, v_off_fin = 84.639 uV 17:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.266 uVs 17:09:41 Integrated Voltage Measurement... 17:09:50 Voltage Offset Correction: v_off_ini = 91.676 uV, v_off_fin = 96.658 uV 17:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.681 uVs 17:09:53 I2Y Average and RMS of Measurements VT = -292.046 +- 12.054 uVs I2Y = -26.868 +- 1.109 uTm^2 17:10:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:11 Integrated Voltage Measurement... 17:10:20 Voltage Offset Correction: v_off_ini = 108.005 uV, v_off_fin = 106.903 uV 17:10:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.911 uVs 17:10:20 Integrated Voltage Measurement... 17:10:29 Voltage Offset Correction: v_off_ini = 95.430 uV, v_off_fin = 94.936 uV 17:10:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.429 uVs 17:10:29 Integrated Voltage Measurement... 17:10:38 Voltage Offset Correction: v_off_ini = 95.810 uV, v_off_fin = 94.541 uV 17:10:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.305 uVs 17:10:38 Integrated Voltage Measurement... 17:10:47 Voltage Offset Correction: v_off_ini = 89.761 uV, v_off_fin = 92.986 uV 17:10:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.662 uVs 17:10:47 Integrated Voltage Measurement... 17:10:56 Voltage Offset Correction: v_off_ini = 83.584 uV, v_off_fin = 88.117 uV 17:10:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.735 uVs 17:10:56 Integrated Voltage Measurement... 17:11:05 Voltage Offset Correction: v_off_ini = 102.753 uV, v_off_fin = 106.989 uV 17:11:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.595 uVs 17:11:09 I1X Average and RMS of Measurements VT = -92.773 +- 5.073 uVs I1X = 18.555 +- 1.015 uTm 17:11:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:16 Integrated Voltage Measurement... 17:11:25 Voltage Offset Correction: v_off_ini = 87.595 uV, v_off_fin = 76.237 uV 17:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.089 uVs 17:11:25 Integrated Voltage Measurement... 17:11:34 Voltage Offset Correction: v_off_ini = 87.738 uV, v_off_fin = 101.722 uV 17:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 272.247 uVs 17:11:34 Integrated Voltage Measurement... 17:11:43 Voltage Offset Correction: v_off_ini = 88.723 uV, v_off_fin = 80.018 uV 17:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -260.119 uVs 17:11:43 Integrated Voltage Measurement... 17:11:52 Voltage Offset Correction: v_off_ini = 83.530 uV, v_off_fin = 115.647 uV 17:11:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 259.208 uVs 17:11:52 Integrated Voltage Measurement... 17:12:01 Voltage Offset Correction: v_off_ini = 104.287 uV, v_off_fin = 80.023 uV 17:12:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -254.613 uVs 17:12:01 Integrated Voltage Measurement... 17:12:10 Voltage Offset Correction: v_off_ini = 86.215 uV, v_off_fin = 97.495 uV 17:12:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 277.376 uVs 17:12:14 I1Y Average and RMS of Measurements VT = -262.775 +- 2.586 uVs I1Y = -52.549 +- 0.517 uTm 17:12:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:22 Integrated Voltage Measurement... 17:12:31 Voltage Offset Correction: v_off_ini = 72.911 uV, v_off_fin = 73.547 uV 17:12:31 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -69.446 uVs 17:12:31 Integrated Voltage Measurement... 17:12:40 Voltage Offset Correction: v_off_ini = 91.918 uV, v_off_fin = 96.713 uV 17:12:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.313 uVs 17:12:40 Integrated Voltage Measurement... 17:12:49 Voltage Offset Correction: v_off_ini = 93.289 uV, v_off_fin = 71.163 uV 17:12:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.733 uVs 17:12:49 Integrated Voltage Measurement... 17:12:58 Voltage Offset Correction: v_off_ini = 78.051 uV, v_off_fin = 101.423 uV 17:12:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.045 uVs 17:12:58 Integrated Voltage Measurement... 17:13:07 Voltage Offset Correction: v_off_ini = 77.029 uV, v_off_fin = 67.257 uV 17:13:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.518 uVs 17:13:07 Integrated Voltage Measurement... 17:13:16 Voltage Offset Correction: v_off_ini = 81.242 uV, v_off_fin = 94.153 uV 17:13:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.685 uVs 17:13:19 I2X Average and RMS of Measurements VT = -88.123 +- 6.624 uVs I2X = 8.107 +- 0.610 uTm^2 17:13:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:26 Integrated Voltage Measurement... 17:13:35 Voltage Offset Correction: v_off_ini = 74.005 uV, v_off_fin = 66.951 uV 17:13:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.737 uVs 17:13:35 Integrated Voltage Measurement... 17:13:44 Voltage Offset Correction: v_off_ini = 77.888 uV, v_off_fin = 69.893 uV 17:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.072 uVs 17:13:45 Integrated Voltage Measurement... 17:13:53 Voltage Offset Correction: v_off_ini = 69.815 uV, v_off_fin = 55.018 uV 17:13:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.694 uVs 17:13:54 Integrated Voltage Measurement... 17:14:03 Voltage Offset Correction: v_off_ini = 61.590 uV, v_off_fin = 50.563 uV 17:14:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.660 uVs 17:14:03 Integrated Voltage Measurement... 17:14:12 Voltage Offset Correction: v_off_ini = 67.146 uV, v_off_fin = 63.233 uV 17:14:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.465 uVs 17:14:12 Integrated Voltage Measurement... 17:14:21 Voltage Offset Correction: v_off_ini = 78.363 uV, v_off_fin = 69.976 uV 17:14:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.630 uVs 17:14:23 I2Y Average and RMS of Measurements VT = -282.710 +- 2.672 uVs I2Y = -26.009 +- 0.246 uTm^2 17:14:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:14:41 Integrated Voltage Measurement... 17:14:50 Voltage Offset Correction: v_off_ini = 99.203 uV, v_off_fin = 88.930 uV 17:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.823 uVs 17:14:50 Integrated Voltage Measurement... 17:14:59 Voltage Offset Correction: v_off_ini = 89.164 uV, v_off_fin = 87.941 uV 17:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.537 uVs 17:14:59 Integrated Voltage Measurement... 17:15:08 Voltage Offset Correction: v_off_ini = 80.968 uV, v_off_fin = 70.515 uV 17:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.967 uVs 17:15:08 Integrated Voltage Measurement... 17:15:17 Voltage Offset Correction: v_off_ini = 88.599 uV, v_off_fin = 85.457 uV 17:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.962 uVs 17:15:17 Integrated Voltage Measurement... 17:15:26 Voltage Offset Correction: v_off_ini = 77.278 uV, v_off_fin = 86.775 uV 17:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.204 uVs 17:15:27 Integrated Voltage Measurement... 17:15:35 Voltage Offset Correction: v_off_ini = 99.844 uV, v_off_fin = 87.383 uV 17:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.207 uVs 17:15:40 I1X Average and RMS of Measurements VT = -86.117 +- 2.982 uVs I1X = 17.223 +- 0.596 uTm 17:15:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:15:47 Integrated Voltage Measurement... 17:15:55 Voltage Offset Correction: v_off_ini = 54.580 uV, v_off_fin = 59.462 uV 17:15:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.396 uVs 17:15:56 Integrated Voltage Measurement... 17:16:04 Voltage Offset Correction: v_off_ini = 80.202 uV, v_off_fin = 99.318 uV 17:16:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 257.628 uVs 17:16:04 Integrated Voltage Measurement... 17:16:13 Voltage Offset Correction: v_off_ini = 84.351 uV, v_off_fin = 73.655 uV 17:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.135 uVs 17:16:14 Integrated Voltage Measurement... 17:16:22 Voltage Offset Correction: v_off_ini = 74.428 uV, v_off_fin = 90.854 uV 17:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.779 uVs 17:16:23 Integrated Voltage Measurement... 17:16:31 Voltage Offset Correction: v_off_ini = 90.346 uV, v_off_fin = 81.719 uV 17:16:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -278.652 uVs 17:16:32 Integrated Voltage Measurement... 17:16:40 Voltage Offset Correction: v_off_ini = 91.859 uV, v_off_fin = 98.684 uV 17:16:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 265.638 uVs 17:16:45 I1Y Average and RMS of Measurements VT = -261.871 +- 7.333 uVs I1Y = -52.370 +- 1.464 uTm 17:16:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:52 Integrated Voltage Measurement... 17:17:01 Voltage Offset Correction: v_off_ini = 102.246 uV, v_off_fin = 91.619 uV 17:17:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -94.463 uVs 17:17:02 Integrated Voltage Measurement... 17:17:11 Voltage Offset Correction: v_off_ini = 102.665 uV, v_off_fin = 103.006 uV 17:17:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.211 uVs 17:17:11 Integrated Voltage Measurement... 17:17:20 Voltage Offset Correction: v_off_ini = 95.063 uV, v_off_fin = 75.128 uV 17:17:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.109 uVs 17:17:20 Integrated Voltage Measurement... 17:17:29 Voltage Offset Correction: v_off_ini = 113.662 uV, v_off_fin = 117.294 uV 17:17:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.116 uVs 17:17:29 Integrated Voltage Measurement... 17:17:38 Voltage Offset Correction: v_off_ini = 98.270 uV, v_off_fin = 95.146 uV 17:17:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.616 uVs 17:17:38 Integrated Voltage Measurement... 17:17:47 Voltage Offset Correction: v_off_ini = 93.722 uV, v_off_fin = 102.402 uV 17:17:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.290 uVs 17:17:49 I2X Average and RMS of Measurements VT = -94.634 +- 6.329 uVs I2X = 8.706 +- 0.583 uTm^2 17:17:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:57 Integrated Voltage Measurement... 17:18:06 Voltage Offset Correction: v_off_ini = 85.523 uV, v_off_fin = 78.123 uV 17:18:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -273.747 uVs 17:18:06 Integrated Voltage Measurement... 17:18:15 Voltage Offset Correction: v_off_ini = 68.339 uV, v_off_fin = 77.062 uV 17:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.395 uVs 17:18:15 Integrated Voltage Measurement... 17:18:24 Voltage Offset Correction: v_off_ini = 70.019 uV, v_off_fin = 64.679 uV 17:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.437 uVs 17:18:24 Integrated Voltage Measurement... 17:18:33 Voltage Offset Correction: v_off_ini = 77.226 uV, v_off_fin = 72.681 uV 17:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.065 uVs 17:18:33 Integrated Voltage Measurement... 17:18:42 Voltage Offset Correction: v_off_ini = 82.801 uV, v_off_fin = 66.811 uV 17:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.670 uVs 17:18:42 Integrated Voltage Measurement... 17:18:51 Voltage Offset Correction: v_off_ini = 75.233 uV, v_off_fin = 68.370 uV 17:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.086 uVs 17:18:53 I2Y Average and RMS of Measurements VT = -281.066 +- 5.674 uVs I2Y = -25.859 +- 0.522 uTm^2 17:19:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:12 Integrated Voltage Measurement... 17:19:21 Voltage Offset Correction: v_off_ini = 59.670 uV, v_off_fin = 45.716 uV 17:19:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.825 uVs 17:19:21 Integrated Voltage Measurement... 17:19:30 Voltage Offset Correction: v_off_ini = 57.461 uV, v_off_fin = 47.592 uV 17:19:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.025 uVs 17:19:30 Integrated Voltage Measurement... 17:19:39 Voltage Offset Correction: v_off_ini = 53.640 uV, v_off_fin = 55.159 uV 17:19:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.922 uVs 17:19:39 Integrated Voltage Measurement... 17:19:48 Voltage Offset Correction: v_off_ini = 55.018 uV, v_off_fin = 55.767 uV 17:19:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.028 uVs 17:19:48 Integrated Voltage Measurement... 17:19:57 Voltage Offset Correction: v_off_ini = 49.030 uV, v_off_fin = 44.611 uV 17:19:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.528 uVs 17:19:57 Integrated Voltage Measurement... 17:20:06 Voltage Offset Correction: v_off_ini = 52.408 uV, v_off_fin = 53.087 uV 17:20:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.103 uVs 17:20:10 I1X Average and RMS of Measurements VT = -91.572 +- 9.798 uVs I1X = 18.315 +- 1.959 uTm 17:20:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:17 Integrated Voltage Measurement... 17:20:26 Voltage Offset Correction: v_off_ini = 48.583 uV, v_off_fin = 35.265 uV 17:20:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -259.690 uVs 17:20:26 Integrated Voltage Measurement... 17:20:35 Voltage Offset Correction: v_off_ini = 50.225 uV, v_off_fin = 65.856 uV 17:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.602 uVs 17:20:35 Integrated Voltage Measurement... 17:20:44 Voltage Offset Correction: v_off_ini = 51.911 uV, v_off_fin = 46.852 uV 17:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.518 uVs 17:20:44 Integrated Voltage Measurement... 17:20:53 Voltage Offset Correction: v_off_ini = 62.626 uV, v_off_fin = 80.044 uV 17:20:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 260.380 uVs 17:20:53 Integrated Voltage Measurement... 17:21:02 Voltage Offset Correction: v_off_ini = 61.483 uV, v_off_fin = 40.681 uV 17:21:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -255.691 uVs 17:21:02 Integrated Voltage Measurement... 17:21:11 Voltage Offset Correction: v_off_ini = 58.572 uV, v_off_fin = 69.857 uV 17:21:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.123 uVs 17:21:15 I1Y Average and RMS of Measurements VT = -260.500 +- 1.566 uVs I1Y = -52.097 +- 0.317 uTm 17:21:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:23 Integrated Voltage Measurement... 17:21:32 Voltage Offset Correction: v_off_ini = 58.918 uV, v_off_fin = 46.296 uV 17:21:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.949 uVs 17:21:32 Integrated Voltage Measurement... 17:21:41 Voltage Offset Correction: v_off_ini = 47.810 uV, v_off_fin = 69.351 uV 17:21:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.765 uVs 17:21:41 Integrated Voltage Measurement... 17:21:50 Voltage Offset Correction: v_off_ini = 40.718 uV, v_off_fin = 54.210 uV 17:21:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.756 uVs 17:21:50 Integrated Voltage Measurement... 17:21:59 Voltage Offset Correction: v_off_ini = 67.223 uV, v_off_fin = 67.178 uV 17:21:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.076 uVs 17:21:59 Integrated Voltage Measurement... 17:22:08 Voltage Offset Correction: v_off_ini = 61.200 uV, v_off_fin = 48.445 uV 17:22:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.042 uVs 17:22:08 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = 58.751 uV, v_off_fin = 66.576 uV 17:22:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.154 uVs 17:22:20 I2X Average and RMS of Measurements VT = -96.457 +- 9.235 uVs I2X = 8.874 +- 0.850 uTm^2 17:22:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:27 Integrated Voltage Measurement... 17:22:36 Voltage Offset Correction: v_off_ini = 61.133 uV, v_off_fin = 54.047 uV 17:22:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.075 uVs 17:22:36 Integrated Voltage Measurement... 17:22:45 Voltage Offset Correction: v_off_ini = 55.776 uV, v_off_fin = 59.250 uV 17:22:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.791 uVs 17:22:45 Integrated Voltage Measurement... 17:22:54 Voltage Offset Correction: v_off_ini = 54.234 uV, v_off_fin = 58.550 uV 17:22:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.547 uVs 17:22:54 Integrated Voltage Measurement... 17:23:03 Voltage Offset Correction: v_off_ini = 44.507 uV, v_off_fin = 63.695 uV 17:23:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.789 uVs 17:23:03 Integrated Voltage Measurement... 17:23:12 Voltage Offset Correction: v_off_ini = 60.100 uV, v_off_fin = 73.227 uV 17:23:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.197 uVs 17:23:13 Integrated Voltage Measurement... 17:23:21 Voltage Offset Correction: v_off_ini = 71.524 uV, v_off_fin = 65.793 uV 17:23:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.286 uVs 17:23:24 I2Y Average and RMS of Measurements VT = -269.781 +- 7.228 uVs I2Y = -24.820 +- 0.665 uTm^2 17:23:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:42 Integrated Voltage Measurement... 17:23:51 Voltage Offset Correction: v_off_ini = 70.129 uV, v_off_fin = 65.223 uV 17:23:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.733 uVs 17:23:51 Integrated Voltage Measurement... 17:24:00 Voltage Offset Correction: v_off_ini = 50.641 uV, v_off_fin = 67.846 uV 17:24:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.731 uVs 17:24:00 Integrated Voltage Measurement... 17:24:09 Voltage Offset Correction: v_off_ini = 60.027 uV, v_off_fin = 58.232 uV 17:24:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.460 uVs 17:24:09 Integrated Voltage Measurement... 17:24:18 Voltage Offset Correction: v_off_ini = 77.585 uV, v_off_fin = 67.916 uV 17:24:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.193 uVs 17:24:18 Integrated Voltage Measurement... 17:24:27 Voltage Offset Correction: v_off_ini = 80.517 uV, v_off_fin = 67.839 uV 17:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.878 uVs 17:24:27 Integrated Voltage Measurement... 17:24:36 Voltage Offset Correction: v_off_ini = 62.277 uV, v_off_fin = 69.747 uV 17:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.590 uVs 17:24:41 I1X Average and RMS of Measurements VT = -95.764 +- 5.970 uVs I1X = 19.153 +- 1.194 uTm 17:24:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:47 Integrated Voltage Measurement... 17:24:56 Voltage Offset Correction: v_off_ini = 75.637 uV, v_off_fin = 61.628 uV 17:24:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -256.848 uVs 17:24:56 Integrated Voltage Measurement... 17:25:05 Voltage Offset Correction: v_off_ini = 71.294 uV, v_off_fin = 86.051 uV 17:25:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.853 uVs 17:25:05 Integrated Voltage Measurement... 17:25:14 Voltage Offset Correction: v_off_ini = 78.345 uV, v_off_fin = 60.103 uV 17:25:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.327 uVs 17:25:14 Integrated Voltage Measurement... 17:25:23 Voltage Offset Correction: v_off_ini = 80.875 uV, v_off_fin = 88.239 uV 17:25:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.919 uVs 17:25:23 Integrated Voltage Measurement... 17:25:32 Voltage Offset Correction: v_off_ini = 78.739 uV, v_off_fin = 69.634 uV 17:25:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.846 uVs 17:25:32 Integrated Voltage Measurement... 17:25:41 Voltage Offset Correction: v_off_ini = 82.326 uV, v_off_fin = 85.817 uV 17:25:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.617 uVs 17:25:46 I1Y Average and RMS of Measurements VT = -256.068 +- 4.230 uVs I1Y = -51.210 +- 0.844 uTm 17:25:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:53 Integrated Voltage Measurement... 17:26:02 Voltage Offset Correction: v_off_ini = 88.248 uV, v_off_fin = 76.796 uV 17:26:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -115.816 uVs 17:26:02 Integrated Voltage Measurement... 17:26:11 Voltage Offset Correction: v_off_ini = 95.298 uV, v_off_fin = 98.293 uV 17:26:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.061 uVs 17:26:11 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = 86.124 uV, v_off_fin = 80.053 uV 17:26:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.525 uVs 17:26:21 Integrated Voltage Measurement... 17:26:29 Voltage Offset Correction: v_off_ini = 99.862 uV, v_off_fin = 94.337 uV 17:26:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.417 uVs 17:26:30 Integrated Voltage Measurement... 17:26:39 Voltage Offset Correction: v_off_ini = 86.700 uV, v_off_fin = 77.672 uV 17:26:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.691 uVs 17:26:39 Integrated Voltage Measurement... 17:26:48 Voltage Offset Correction: v_off_ini = 80.415 uV, v_off_fin = 104.064 uV 17:26:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.426 uVs 17:26:50 I2X Average and RMS of Measurements VT = -106.156 +- 4.830 uVs I2X = 9.766 +- 0.444 uTm^2 17:26:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:58 Integrated Voltage Measurement... 17:27:07 Voltage Offset Correction: v_off_ini = 72.204 uV, v_off_fin = 71.965 uV 17:27:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.878 uVs 17:27:07 Integrated Voltage Measurement... 17:27:16 Voltage Offset Correction: v_off_ini = 66.558 uV, v_off_fin = 77.898 uV 17:27:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.907 uVs 17:27:16 Integrated Voltage Measurement... 17:27:25 Voltage Offset Correction: v_off_ini = 82.383 uV, v_off_fin = 69.639 uV 17:27:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.652 uVs 17:27:25 Integrated Voltage Measurement... 17:27:34 Voltage Offset Correction: v_off_ini = 82.520 uV, v_off_fin = 88.439 uV 17:27:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.690 uVs 17:27:34 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = 88.916 uV, v_off_fin = 93.900 uV 17:27:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.981 uVs 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = 99.407 uV, v_off_fin = 94.458 uV 17:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.460 uVs 17:27:54 I2Y Average and RMS of Measurements VT = -262.261 +- 6.076 uVs I2Y = -24.128 +- 0.559 uTm^2 17:27:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm