SLAC Magnetic Measurements Date: 10-13-2025 Time: 14:43:09 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16346 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 14:44:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:10 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:44:12 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:44:13 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:44:15 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:46:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:25 Integrated Voltage Measurement... 14:46:34 Voltage Offset Correction: v_off_ini = -213.734 uV, v_off_fin = -207.195 uV 14:46:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -48.314 uVs 14:46:34 Integrated Voltage Measurement... 14:46:43 Voltage Offset Correction: v_off_ini = -211.241 uV, v_off_fin = -207.902 uV 14:46:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 48.609 uVs 14:46:43 Integrated Voltage Measurement... 14:46:52 Voltage Offset Correction: v_off_ini = -215.732 uV, v_off_fin = -224.870 uV 14:46:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.420 uVs 14:46:52 Integrated Voltage Measurement... 14:47:01 Voltage Offset Correction: v_off_ini = -218.606 uV, v_off_fin = -204.985 uV 14:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.670 uVs 14:47:01 Integrated Voltage Measurement... 14:47:10 Voltage Offset Correction: v_off_ini = -198.046 uV, v_off_fin = -205.608 uV 14:47:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -64.023 uVs 14:47:10 Integrated Voltage Measurement... 14:47:19 Voltage Offset Correction: v_off_ini = -207.303 uV, v_off_fin = -203.716 uV 14:47:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.502 uVs 14:47:23 I1X Average and RMS of Measurements VT = -50.256 +- 5.147 uVs I1X = 10.052 +- 1.029 uTm 14:47:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:30 Integrated Voltage Measurement... 14:47:39 Voltage Offset Correction: v_off_ini = -211.486 uV, v_off_fin = -226.715 uV 14:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.673 uVs 14:47:39 Integrated Voltage Measurement... 14:47:48 Voltage Offset Correction: v_off_ini = -217.911 uV, v_off_fin = -204.212 uV 14:47:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.622 uVs 14:47:48 Integrated Voltage Measurement... 14:47:57 Voltage Offset Correction: v_off_ini = -221.392 uV, v_off_fin = -225.994 uV 14:47:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.992 uVs 14:47:57 Integrated Voltage Measurement... 14:48:06 Voltage Offset Correction: v_off_ini = -216.486 uV, v_off_fin = -205.203 uV 14:48:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.290 uVs 14:48:06 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = -206.310 uV, v_off_fin = -219.793 uV 14:48:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.740 uVs 14:48:15 Integrated Voltage Measurement... 14:48:24 Voltage Offset Correction: v_off_ini = -217.650 uV, v_off_fin = -208.606 uV 14:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.018 uVs 14:48:28 I1Y Average and RMS of Measurements VT = -167.056 +- 7.046 uVs I1Y = -33.411 +- 1.409 uTm 14:48:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:35 Integrated Voltage Measurement... 14:48:44 Voltage Offset Correction: v_off_ini = -201.122 uV, v_off_fin = -205.658 uV 14:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.726 uVs 14:48:44 Integrated Voltage Measurement... 14:48:53 Voltage Offset Correction: v_off_ini = -201.942 uV, v_off_fin = -183.304 uV 14:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.431 uVs 14:48:54 Integrated Voltage Measurement... 14:49:02 Voltage Offset Correction: v_off_ini = -183.252 uV, v_off_fin = -197.369 uV 14:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.756 uVs 14:49:03 Integrated Voltage Measurement... 14:49:11 Voltage Offset Correction: v_off_ini = -201.488 uV, v_off_fin = -199.248 uV 14:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.988 uVs 14:49:12 Integrated Voltage Measurement... 14:49:21 Voltage Offset Correction: v_off_ini = -204.380 uV, v_off_fin = -213.660 uV 14:49:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.738 uVs 14:49:21 Integrated Voltage Measurement... 14:49:30 Voltage Offset Correction: v_off_ini = -212.190 uV, v_off_fin = -198.790 uV 14:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.972 uVs 14:49:32 I2X Average and RMS of Measurements VT = -96.102 +- 0.722 uVs I2X = 8.841 +- 0.066 uTm^2 14:49:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:40 Integrated Voltage Measurement... 14:49:49 Voltage Offset Correction: v_off_ini = -206.050 uV, v_off_fin = -207.066 uV 14:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.701 uVs 14:49:49 Integrated Voltage Measurement... 14:49:58 Voltage Offset Correction: v_off_ini = -197.929 uV, v_off_fin = -193.434 uV 14:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.466 uVs 14:49:58 Integrated Voltage Measurement... 14:50:07 Voltage Offset Correction: v_off_ini = -209.273 uV, v_off_fin = -181.446 uV 14:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.946 uVs 14:50:07 Integrated Voltage Measurement... 14:50:16 Voltage Offset Correction: v_off_ini = -193.194 uV, v_off_fin = -186.074 uV 14:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.567 uVs 14:50:16 Integrated Voltage Measurement... 14:50:25 Voltage Offset Correction: v_off_ini = -189.235 uV, v_off_fin = -183.951 uV 14:50:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.666 uVs 14:50:25 Integrated Voltage Measurement... 14:50:34 Voltage Offset Correction: v_off_ini = -188.488 uV, v_off_fin = -185.460 uV 14:50:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.116 uVs 14:50:36 I2Y Average and RMS of Measurements VT = -231.910 +- 4.435 uVs I2Y = -21.336 +- 0.408 uTm^2 14:50:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:51 Integrated Voltage Measurement... 14:51:00 Voltage Offset Correction: v_off_ini = -192.316 uV, v_off_fin = -193.835 uV 14:51:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.454 uVs 14:51:00 Integrated Voltage Measurement... 14:51:09 Voltage Offset Correction: v_off_ini = -195.803 uV, v_off_fin = -171.760 uV 14:51:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.315 uVs 14:51:09 Integrated Voltage Measurement... 14:51:18 Voltage Offset Correction: v_off_ini = -182.995 uV, v_off_fin = -185.343 uV 14:51:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.545 uVs 14:51:18 Integrated Voltage Measurement... 14:51:27 Voltage Offset Correction: v_off_ini = -179.707 uV, v_off_fin = -184.454 uV 14:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.721 uVs 14:51:27 Integrated Voltage Measurement... 14:51:36 Voltage Offset Correction: v_off_ini = -188.824 uV, v_off_fin = -180.261 uV 14:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.180 uVs 14:51:36 Integrated Voltage Measurement... 14:51:45 Voltage Offset Correction: v_off_ini = -177.824 uV, v_off_fin = -172.061 uV 14:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.622 uVs 14:51:49 I1X Average and RMS of Measurements VT = -55.640 +- 1.623 uVs I1X = 11.128 +- 0.325 uTm 14:51:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:56 Integrated Voltage Measurement... 14:52:05 Voltage Offset Correction: v_off_ini = -178.808 uV, v_off_fin = -191.326 uV 14:52:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.935 uVs 14:52:05 Integrated Voltage Measurement... 14:52:14 Voltage Offset Correction: v_off_ini = -183.840 uV, v_off_fin = -166.896 uV 14:52:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.396 uVs 14:52:14 Integrated Voltage Measurement... 14:52:23 Voltage Offset Correction: v_off_ini = -173.597 uV, v_off_fin = -177.859 uV 14:52:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.164 uVs 14:52:23 Integrated Voltage Measurement... 14:52:32 Voltage Offset Correction: v_off_ini = -164.648 uV, v_off_fin = -160.242 uV 14:52:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.547 uVs 14:52:32 Integrated Voltage Measurement... 14:52:41 Voltage Offset Correction: v_off_ini = -168.493 uV, v_off_fin = -174.275 uV 14:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.559 uVs 14:52:41 Integrated Voltage Measurement... 14:52:50 Voltage Offset Correction: v_off_ini = -168.018 uV, v_off_fin = -155.276 uV 14:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.058 uVs 14:52:54 I1Y Average and RMS of Measurements VT = -186.777 +- 1.208 uVs I1Y = -37.356 +- 0.242 uTm 14:52:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:02 Integrated Voltage Measurement... 14:53:11 Voltage Offset Correction: v_off_ini = -159.198 uV, v_off_fin = -165.157 uV 14:53:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.052 uVs 14:53:11 Integrated Voltage Measurement... 14:53:20 Voltage Offset Correction: v_off_ini = -143.188 uV, v_off_fin = -136.777 uV 14:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.459 uVs 14:53:20 Integrated Voltage Measurement... 14:53:29 Voltage Offset Correction: v_off_ini = -144.798 uV, v_off_fin = -143.413 uV 14:53:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.399 uVs 14:53:29 Integrated Voltage Measurement... 14:53:38 Voltage Offset Correction: v_off_ini = -151.809 uV, v_off_fin = -148.949 uV 14:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.817 uVs 14:53:38 Integrated Voltage Measurement... 14:53:47 Voltage Offset Correction: v_off_ini = -161.006 uV, v_off_fin = -168.083 uV 14:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.989 uVs 14:53:47 Integrated Voltage Measurement... 14:53:56 Voltage Offset Correction: v_off_ini = -152.830 uV, v_off_fin = -141.529 uV 14:53:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.781 uVs 14:53:58 I2X Average and RMS of Measurements VT = -73.416 +- 7.855 uVs I2X = 6.754 +- 0.723 uTm^2 14:54:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:06 Integrated Voltage Measurement... 14:54:15 Voltage Offset Correction: v_off_ini = -157.162 uV, v_off_fin = -165.003 uV 14:54:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -277.394 uVs 14:54:15 Integrated Voltage Measurement... 14:54:24 Voltage Offset Correction: v_off_ini = -162.093 uV, v_off_fin = -154.749 uV 14:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.733 uVs 14:54:24 Integrated Voltage Measurement... 14:54:33 Voltage Offset Correction: v_off_ini = -147.658 uV, v_off_fin = -153.634 uV 14:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.781 uVs 14:54:33 Integrated Voltage Measurement... 14:54:42 Voltage Offset Correction: v_off_ini = -170.539 uV, v_off_fin = -159.209 uV 14:54:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.527 uVs 14:54:42 Integrated Voltage Measurement... 14:54:51 Voltage Offset Correction: v_off_ini = -159.692 uV, v_off_fin = -158.541 uV 14:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.711 uVs 14:54:51 Integrated Voltage Measurement... 14:55:00 Voltage Offset Correction: v_off_ini = -160.827 uV, v_off_fin = -165.011 uV 14:55:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.569 uVs 14:55:02 I2Y Average and RMS of Measurements VT = -260.952 +- 17.323 uVs I2Y = -24.008 +- 1.594 uTm^2 14:55:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:17 Integrated Voltage Measurement... 14:55:26 Voltage Offset Correction: v_off_ini = -140.163 uV, v_off_fin = -158.871 uV 14:55:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.873 uVs 14:55:26 Integrated Voltage Measurement... 14:55:35 Voltage Offset Correction: v_off_ini = -156.445 uV, v_off_fin = -145.824 uV 14:55:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.564 uVs 14:55:35 Integrated Voltage Measurement... 14:55:44 Voltage Offset Correction: v_off_ini = -162.532 uV, v_off_fin = -152.377 uV 14:55:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.628 uVs 14:55:44 Integrated Voltage Measurement... 14:55:53 Voltage Offset Correction: v_off_ini = -168.993 uV, v_off_fin = -165.299 uV 14:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.549 uVs 14:55:53 Integrated Voltage Measurement... 14:56:02 Voltage Offset Correction: v_off_ini = -165.610 uV, v_off_fin = -169.603 uV 14:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.478 uVs 14:56:02 Integrated Voltage Measurement... 14:56:11 Voltage Offset Correction: v_off_ini = -145.896 uV, v_off_fin = -139.859 uV 14:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.641 uVs 14:56:16 I1X Average and RMS of Measurements VT = -57.622 +- 11.219 uVs I1X = 11.524 +- 2.244 uTm 14:56:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:22 Integrated Voltage Measurement... 14:56:31 Voltage Offset Correction: v_off_ini = -161.037 uV, v_off_fin = -163.888 uV 14:56:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -201.214 uVs 14:56:31 Integrated Voltage Measurement... 14:56:40 Voltage Offset Correction: v_off_ini = -163.114 uV, v_off_fin = -139.019 uV 14:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.631 uVs 14:56:40 Integrated Voltage Measurement... 14:56:49 Voltage Offset Correction: v_off_ini = -147.557 uV, v_off_fin = -165.531 uV 14:56:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.322 uVs 14:56:49 Integrated Voltage Measurement... 14:56:58 Voltage Offset Correction: v_off_ini = -168.951 uV, v_off_fin = -156.369 uV 14:56:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.937 uVs 14:56:58 Integrated Voltage Measurement... 14:57:07 Voltage Offset Correction: v_off_ini = -155.239 uV, v_off_fin = -159.080 uV 14:57:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.046 uVs 14:57:07 Integrated Voltage Measurement... 14:57:16 Voltage Offset Correction: v_off_ini = -161.325 uV, v_off_fin = -146.580 uV 14:57:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.646 uVs 14:57:20 I1Y Average and RMS of Measurements VT = -205.133 +- 5.782 uVs I1Y = -41.024 +- 1.155 uTm 14:57:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:28 Integrated Voltage Measurement... 14:57:37 Voltage Offset Correction: v_off_ini = -147.677 uV, v_off_fin = -140.098 uV 14:57:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.060 uVs 14:57:37 Integrated Voltage Measurement... 14:57:46 Voltage Offset Correction: v_off_ini = -153.230 uV, v_off_fin = -141.759 uV 14:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.751 uVs 14:57:46 Integrated Voltage Measurement... 14:57:55 Voltage Offset Correction: v_off_ini = -164.177 uV, v_off_fin = -157.974 uV 14:57:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.636 uVs 14:57:55 Integrated Voltage Measurement... 14:58:04 Voltage Offset Correction: v_off_ini = -148.046 uV, v_off_fin = -157.363 uV 14:58:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.284 uVs 14:58:04 Integrated Voltage Measurement... 14:58:13 Voltage Offset Correction: v_off_ini = -147.250 uV, v_off_fin = -153.630 uV 14:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.471 uVs 14:58:13 Integrated Voltage Measurement... 14:58:22 Voltage Offset Correction: v_off_ini = -159.091 uV, v_off_fin = -146.307 uV 14:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.118 uVs 14:58:25 I2X Average and RMS of Measurements VT = -83.053 +- 4.492 uVs I2X = 7.641 +- 0.413 uTm^2 14:58:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:32 Integrated Voltage Measurement... 14:58:41 Voltage Offset Correction: v_off_ini = -161.283 uV, v_off_fin = -170.795 uV 14:58:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.620 uVs 14:58:41 Integrated Voltage Measurement... 14:58:50 Voltage Offset Correction: v_off_ini = -156.629 uV, v_off_fin = -153.327 uV 14:58:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.767 uVs 14:58:50 Integrated Voltage Measurement... 14:58:59 Voltage Offset Correction: v_off_ini = -160.058 uV, v_off_fin = -156.557 uV 14:58:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.031 uVs 14:58:59 Integrated Voltage Measurement... 14:59:08 Voltage Offset Correction: v_off_ini = -147.150 uV, v_off_fin = -166.243 uV 14:59:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.218 uVs 14:59:08 Integrated Voltage Measurement... 14:59:17 Voltage Offset Correction: v_off_ini = -155.383 uV, v_off_fin = -158.120 uV 14:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.017 uVs 14:59:17 Integrated Voltage Measurement... 14:59:26 Voltage Offset Correction: v_off_ini = -164.134 uV, v_off_fin = -151.796 uV 14:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.247 uVs 14:59:29 I2Y Average and RMS of Measurements VT = -269.817 +- 12.095 uVs I2Y = -24.823 +- 1.113 uTm^2 14:59:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:44 Integrated Voltage Measurement... 14:59:53 Voltage Offset Correction: v_off_ini = -149.717 uV, v_off_fin = -160.430 uV 14:59:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.619 uVs 14:59:53 Integrated Voltage Measurement... 15:00:02 Voltage Offset Correction: v_off_ini = -161.955 uV, v_off_fin = -152.493 uV 15:00:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.572 uVs 15:00:02 Integrated Voltage Measurement... 15:00:11 Voltage Offset Correction: v_off_ini = -152.906 uV, v_off_fin = -151.764 uV 15:00:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.164 uVs 15:00:11 Integrated Voltage Measurement... 15:00:20 Voltage Offset Correction: v_off_ini = -147.686 uV, v_off_fin = -151.700 uV 15:00:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.590 uVs 15:00:20 Integrated Voltage Measurement... 15:00:29 Voltage Offset Correction: v_off_ini = -153.520 uV, v_off_fin = -150.574 uV 15:00:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.222 uVs 15:00:29 Integrated Voltage Measurement... 15:00:38 Voltage Offset Correction: v_off_ini = -158.343 uV, v_off_fin = -155.816 uV 15:00:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.368 uVs 15:00:42 I1X Average and RMS of Measurements VT = -58.422 +- 8.015 uVs I1X = 11.685 +- 1.603 uTm 15:00:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:49 Integrated Voltage Measurement... 15:00:57 Voltage Offset Correction: v_off_ini = -137.420 uV, v_off_fin = -143.961 uV 15:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -219.797 uVs 15:00:58 Integrated Voltage Measurement... 15:01:06 Voltage Offset Correction: v_off_ini = -138.126 uV, v_off_fin = -130.409 uV 15:01:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.236 uVs 15:01:07 Integrated Voltage Measurement... 15:01:15 Voltage Offset Correction: v_off_ini = -148.071 uV, v_off_fin = -151.861 uV 15:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.217 uVs 15:01:16 Integrated Voltage Measurement... 15:01:24 Voltage Offset Correction: v_off_ini = -136.793 uV, v_off_fin = -135.744 uV 15:01:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.989 uVs 15:01:25 Integrated Voltage Measurement... 15:01:33 Voltage Offset Correction: v_off_ini = -134.222 uV, v_off_fin = -145.160 uV 15:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.733 uVs 15:01:34 Integrated Voltage Measurement... 15:01:42 Voltage Offset Correction: v_off_ini = -157.508 uV, v_off_fin = -141.633 uV 15:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.775 uVs 15:01:47 I1Y Average and RMS of Measurements VT = -215.458 +- 4.172 uVs I1Y = -43.092 +- 0.834 uTm 15:01:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:54 Integrated Voltage Measurement... 15:02:03 Voltage Offset Correction: v_off_ini = -140.670 uV, v_off_fin = -155.488 uV 15:02:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.369 uVs 15:02:03 Integrated Voltage Measurement... 15:02:12 Voltage Offset Correction: v_off_ini = -154.139 uV, v_off_fin = -148.620 uV 15:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.221 uVs 15:02:12 Integrated Voltage Measurement... 15:02:21 Voltage Offset Correction: v_off_ini = -151.673 uV, v_off_fin = -150.902 uV 15:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.105 uVs 15:02:21 Integrated Voltage Measurement... 15:02:30 Voltage Offset Correction: v_off_ini = -154.975 uV, v_off_fin = -137.090 uV 15:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.300 uVs 15:02:30 Integrated Voltage Measurement... 15:02:39 Voltage Offset Correction: v_off_ini = -170.478 uV, v_off_fin = -171.215 uV 15:02:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.860 uVs 15:02:40 Integrated Voltage Measurement... 15:02:48 Voltage Offset Correction: v_off_ini = -151.654 uV, v_off_fin = -150.050 uV 15:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.488 uVs 15:02:51 I2X Average and RMS of Measurements VT = -89.057 +- 16.898 uVs I2X = 8.193 +- 1.554 uTm^2 15:02:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:59 Integrated Voltage Measurement... 15:03:08 Voltage Offset Correction: v_off_ini = -154.745 uV, v_off_fin = -150.883 uV 15:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.887 uVs 15:03:08 Integrated Voltage Measurement... 15:03:17 Voltage Offset Correction: v_off_ini = -148.913 uV, v_off_fin = -153.738 uV 15:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.208 uVs 15:03:17 Integrated Voltage Measurement... 15:03:26 Voltage Offset Correction: v_off_ini = -163.900 uV, v_off_fin = -147.191 uV 15:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.117 uVs 15:03:26 Integrated Voltage Measurement... 15:03:35 Voltage Offset Correction: v_off_ini = -138.980 uV, v_off_fin = -135.334 uV 15:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.315 uVs 15:03:35 Integrated Voltage Measurement... 15:03:44 Voltage Offset Correction: v_off_ini = -127.142 uV, v_off_fin = -129.068 uV 15:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.416 uVs 15:03:44 Integrated Voltage Measurement... 15:03:53 Voltage Offset Correction: v_off_ini = -129.538 uV, v_off_fin = -134.128 uV 15:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.006 uVs 15:03:55 I2Y Average and RMS of Measurements VT = -287.158 +- 4.340 uVs I2Y = -26.419 +- 0.399 uTm^2 15:04:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:10 Integrated Voltage Measurement... 15:04:19 Voltage Offset Correction: v_off_ini = -156.639 uV, v_off_fin = -162.904 uV 15:04:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.564 uVs 15:04:19 Integrated Voltage Measurement... 15:04:28 Voltage Offset Correction: v_off_ini = -153.860 uV, v_off_fin = -150.835 uV 15:04:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.021 uVs 15:04:28 Integrated Voltage Measurement... 15:04:37 Voltage Offset Correction: v_off_ini = -148.606 uV, v_off_fin = -149.299 uV 15:04:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.112 uVs 15:04:37 Integrated Voltage Measurement... 15:04:46 Voltage Offset Correction: v_off_ini = -143.059 uV, v_off_fin = -145.910 uV 15:04:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.264 uVs 15:04:46 Integrated Voltage Measurement... 15:04:55 Voltage Offset Correction: v_off_ini = -142.276 uV, v_off_fin = -155.203 uV 15:04:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.947 uVs 15:04:55 Integrated Voltage Measurement... 15:05:04 Voltage Offset Correction: v_off_ini = -142.265 uV, v_off_fin = -130.903 uV 15:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.782 uVs 15:05:08 I1X Average and RMS of Measurements VT = -62.615 +- 3.851 uVs I1X = 12.523 +- 0.770 uTm 15:05:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:15 Integrated Voltage Measurement... 15:05:24 Voltage Offset Correction: v_off_ini = -156.007 uV, v_off_fin = -136.414 uV 15:05:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -238.057 uVs 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = -124.493 uV, v_off_fin = -112.211 uV 15:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.418 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = -127.463 uV, v_off_fin = -137.776 uV 15:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.812 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = -132.338 uV, v_off_fin = -115.673 uV 15:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.421 uVs 15:05:51 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = -126.686 uV, v_off_fin = -147.678 uV 15:06:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.077 uVs 15:06:00 Integrated Voltage Measurement... 15:06:09 Voltage Offset Correction: v_off_ini = -136.687 uV, v_off_fin = -120.540 uV 15:06:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.873 uVs 15:06:13 I1Y Average and RMS of Measurements VT = -236.276 +- 9.548 uVs I1Y = -47.256 +- 1.909 uTm 15:06:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = -134.877 uV, v_off_fin = -147.154 uV 15:06:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -88.694 uVs 15:06:30 Integrated Voltage Measurement... 15:06:39 Voltage Offset Correction: v_off_ini = -121.029 uV, v_off_fin = -119.257 uV 15:06:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.682 uVs 15:06:39 Integrated Voltage Measurement... 15:06:48 Voltage Offset Correction: v_off_ini = -115.980 uV, v_off_fin = -120.908 uV 15:06:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.455 uVs 15:06:48 Integrated Voltage Measurement... 15:06:57 Voltage Offset Correction: v_off_ini = -111.001 uV, v_off_fin = -112.486 uV 15:06:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.620 uVs 15:06:57 Integrated Voltage Measurement... 15:07:06 Voltage Offset Correction: v_off_ini = -130.363 uV, v_off_fin = -130.464 uV 15:07:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.742 uVs 15:07:06 Integrated Voltage Measurement... 15:07:15 Voltage Offset Correction: v_off_ini = -125.796 uV, v_off_fin = -106.251 uV 15:07:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.799 uVs 15:07:17 I2X Average and RMS of Measurements VT = -89.165 +- 5.900 uVs I2X = 8.203 +- 0.543 uTm^2 15:07:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:25 Integrated Voltage Measurement... 15:07:34 Voltage Offset Correction: v_off_ini = -115.979 uV, v_off_fin = -110.647 uV 15:07:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.435 uVs 15:07:34 Integrated Voltage Measurement... 15:07:43 Voltage Offset Correction: v_off_ini = -108.217 uV, v_off_fin = -105.283 uV 15:07:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.099 uVs 15:07:43 Integrated Voltage Measurement... 15:07:52 Voltage Offset Correction: v_off_ini = -94.327 uV, v_off_fin = -96.667 uV 15:07:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.341 uVs 15:07:52 Integrated Voltage Measurement... 15:08:01 Voltage Offset Correction: v_off_ini = -100.038 uV, v_off_fin = -100.402 uV 15:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.914 uVs 15:08:01 Integrated Voltage Measurement... 15:08:10 Voltage Offset Correction: v_off_ini = -107.010 uV, v_off_fin = -110.124 uV 15:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.459 uVs 15:08:10 Integrated Voltage Measurement... 15:08:19 Voltage Offset Correction: v_off_ini = -102.465 uV, v_off_fin = -108.383 uV 15:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.726 uVs 15:08:22 I2Y Average and RMS of Measurements VT = -299.329 +- 1.602 uVs I2Y = -27.538 +- 0.147 uTm^2 15:08:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:37 Integrated Voltage Measurement... 15:08:46 Voltage Offset Correction: v_off_ini = -98.748 uV, v_off_fin = -111.889 uV 15:08:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.789 uVs 15:08:46 Integrated Voltage Measurement... 15:08:55 Voltage Offset Correction: v_off_ini = -100.836 uV, v_off_fin = -95.685 uV 15:08:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.353 uVs 15:08:55 Integrated Voltage Measurement... 15:09:04 Voltage Offset Correction: v_off_ini = -113.669 uV, v_off_fin = -100.041 uV 15:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.195 uVs 15:09:04 Integrated Voltage Measurement... 15:09:13 Voltage Offset Correction: v_off_ini = -88.149 uV, v_off_fin = -93.235 uV 15:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.018 uVs 15:09:13 Integrated Voltage Measurement... 15:09:22 Voltage Offset Correction: v_off_ini = -98.211 uV, v_off_fin = -108.700 uV 15:09:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.609 uVs 15:09:22 Integrated Voltage Measurement... 15:09:31 Voltage Offset Correction: v_off_ini = -99.099 uV, v_off_fin = -91.798 uV 15:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.204 uVs 15:09:35 I1X Average and RMS of Measurements VT = -67.028 +- 2.522 uVs I1X = 13.406 +- 0.504 uTm 15:09:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:42 Integrated Voltage Measurement... 15:09:51 Voltage Offset Correction: v_off_ini = -96.389 uV, v_off_fin = -103.308 uV 15:09:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -236.887 uVs 15:09:51 Integrated Voltage Measurement... 15:10:00 Voltage Offset Correction: v_off_ini = -91.764 uV, v_off_fin = -90.005 uV 15:10:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.495 uVs 15:10:00 Integrated Voltage Measurement... 15:10:09 Voltage Offset Correction: v_off_ini = -101.317 uV, v_off_fin = -118.792 uV 15:10:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.559 uVs 15:10:09 Integrated Voltage Measurement... 15:10:18 Voltage Offset Correction: v_off_ini = -115.748 uV, v_off_fin = -102.433 uV 15:10:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.745 uVs 15:10:18 Integrated Voltage Measurement... 15:10:27 Voltage Offset Correction: v_off_ini = -102.180 uV, v_off_fin = -115.008 uV 15:10:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -245.217 uVs 15:10:27 Integrated Voltage Measurement... 15:10:36 Voltage Offset Correction: v_off_ini = -99.583 uV, v_off_fin = -83.376 uV 15:10:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 241.778 uVs 15:10:41 I1Y Average and RMS of Measurements VT = -241.113 +- 5.359 uVs I1Y = -48.221 +- 1.069 uTm 15:10:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:48 Integrated Voltage Measurement... 15:10:57 Voltage Offset Correction: v_off_ini = -101.001 uV, v_off_fin = -110.578 uV 15:10:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.270 uVs 15:10:57 Integrated Voltage Measurement... 15:11:06 Voltage Offset Correction: v_off_ini = -93.923 uV, v_off_fin = -78.910 uV 15:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.828 uVs 15:11:06 Integrated Voltage Measurement... 15:11:15 Voltage Offset Correction: v_off_ini = -87.523 uV, v_off_fin = -89.488 uV 15:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.504 uVs 15:11:15 Integrated Voltage Measurement... 15:11:24 Voltage Offset Correction: v_off_ini = -90.757 uV, v_off_fin = -81.098 uV 15:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.065 uVs 15:11:24 Integrated Voltage Measurement... 15:11:33 Voltage Offset Correction: v_off_ini = -97.157 uV, v_off_fin = -98.788 uV 15:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.885 uVs 15:11:33 Integrated Voltage Measurement... 15:11:42 Voltage Offset Correction: v_off_ini = -102.594 uV, v_off_fin = -83.270 uV 15:11:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.197 uVs 15:11:45 I2X Average and RMS of Measurements VT = -97.125 +- 4.012 uVs I2X = 8.935 +- 0.369 uTm^2 15:11:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:52 Integrated Voltage Measurement... 15:12:01 Voltage Offset Correction: v_off_ini = -99.950 uV, v_off_fin = -97.677 uV 15:12:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.973 uVs 15:12:01 Integrated Voltage Measurement... 15:12:10 Voltage Offset Correction: v_off_ini = -110.380 uV, v_off_fin = -114.433 uV 15:12:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.534 uVs 15:12:10 Integrated Voltage Measurement... 15:12:19 Voltage Offset Correction: v_off_ini = -115.024 uV, v_off_fin = -113.650 uV 15:12:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.729 uVs 15:12:19 Integrated Voltage Measurement... 15:12:28 Voltage Offset Correction: v_off_ini = -105.631 uV, v_off_fin = -106.607 uV 15:12:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.788 uVs 15:12:28 Integrated Voltage Measurement... 15:12:37 Voltage Offset Correction: v_off_ini = -121.371 uV, v_off_fin = -103.391 uV 15:12:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.543 uVs 15:12:37 Integrated Voltage Measurement... 15:12:46 Voltage Offset Correction: v_off_ini = -111.560 uV, v_off_fin = -106.849 uV 15:12:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.937 uVs 15:12:49 I2Y Average and RMS of Measurements VT = -306.584 +- 2.775 uVs I2Y = -28.206 +- 0.255 uTm^2 15:13:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:04 Integrated Voltage Measurement... 15:13:13 Voltage Offset Correction: v_off_ini = -81.273 uV, v_off_fin = -90.292 uV 15:13:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.149 uVs 15:13:13 Integrated Voltage Measurement... 15:13:22 Voltage Offset Correction: v_off_ini = -88.973 uV, v_off_fin = -62.697 uV 15:13:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.188 uVs 15:13:22 Integrated Voltage Measurement... 15:13:31 Voltage Offset Correction: v_off_ini = -69.487 uV, v_off_fin = -83.612 uV 15:13:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.228 uVs 15:13:31 Integrated Voltage Measurement... 15:13:40 Voltage Offset Correction: v_off_ini = -99.107 uV, v_off_fin = -90.646 uV 15:13:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.504 uVs 15:13:40 Integrated Voltage Measurement... 15:13:49 Voltage Offset Correction: v_off_ini = -96.656 uV, v_off_fin = -86.983 uV 15:13:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.658 uVs 15:13:49 Integrated Voltage Measurement... 15:13:58 Voltage Offset Correction: v_off_ini = -101.280 uV, v_off_fin = -92.740 uV 15:13:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.890 uVs 15:14:02 I1X Average and RMS of Measurements VT = -74.936 +- 5.094 uVs I1X = 14.987 +- 1.019 uTm 15:14:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:09 Integrated Voltage Measurement... 15:14:18 Voltage Offset Correction: v_off_ini = -102.701 uV, v_off_fin = -96.983 uV 15:14:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.035 uVs 15:14:18 Integrated Voltage Measurement... 15:14:27 Voltage Offset Correction: v_off_ini = -93.331 uV, v_off_fin = -88.756 uV 15:14:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.791 uVs 15:14:27 Integrated Voltage Measurement... 15:14:36 Voltage Offset Correction: v_off_ini = -101.888 uV, v_off_fin = -113.360 uV 15:14:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -260.867 uVs 15:14:36 Integrated Voltage Measurement... 15:14:45 Voltage Offset Correction: v_off_ini = -108.592 uV, v_off_fin = -89.524 uV 15:14:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.033 uVs 15:14:45 Integrated Voltage Measurement... 15:14:54 Voltage Offset Correction: v_off_ini = -96.549 uV, v_off_fin = -101.834 uV 15:14:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -265.623 uVs 15:14:54 Integrated Voltage Measurement... 15:15:03 Voltage Offset Correction: v_off_ini = -93.906 uV, v_off_fin = -88.437 uV 15:15:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.142 uVs 15:15:07 I1Y Average and RMS of Measurements VT = -256.749 +- 3.656 uVs I1Y = -51.345 +- 0.732 uTm 15:15:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:14 Integrated Voltage Measurement... 15:15:23 Voltage Offset Correction: v_off_ini = -107.186 uV, v_off_fin = -114.570 uV 15:15:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -100.767 uVs 15:15:24 Integrated Voltage Measurement... 15:15:32 Voltage Offset Correction: v_off_ini = -107.389 uV, v_off_fin = -95.413 uV 15:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.838 uVs 15:15:33 Integrated Voltage Measurement... 15:15:41 Voltage Offset Correction: v_off_ini = -101.176 uV, v_off_fin = -97.651 uV 15:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.982 uVs 15:15:42 Integrated Voltage Measurement... 15:15:51 Voltage Offset Correction: v_off_ini = -95.341 uV, v_off_fin = -94.256 uV 15:15:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.998 uVs 15:15:51 Integrated Voltage Measurement... 15:16:00 Voltage Offset Correction: v_off_ini = -90.921 uV, v_off_fin = -99.020 uV 15:16:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.648 uVs 15:16:00 Integrated Voltage Measurement... 15:16:09 Voltage Offset Correction: v_off_ini = -90.475 uV, v_off_fin = -80.341 uV 15:16:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.336 uVs 15:16:11 I2X Average and RMS of Measurements VT = -93.761 +- 7.183 uVs I2X = 8.626 +- 0.661 uTm^2 15:16:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:19 Integrated Voltage Measurement... 15:16:28 Voltage Offset Correction: v_off_ini = -81.580 uV, v_off_fin = -82.409 uV 15:16:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.706 uVs 15:16:28 Integrated Voltage Measurement... 15:16:37 Voltage Offset Correction: v_off_ini = -77.259 uV, v_off_fin = -85.190 uV 15:16:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.094 uVs 15:16:37 Integrated Voltage Measurement... 15:16:46 Voltage Offset Correction: v_off_ini = -85.201 uV, v_off_fin = -83.554 uV 15:16:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.509 uVs 15:16:46 Integrated Voltage Measurement... 15:16:55 Voltage Offset Correction: v_off_ini = -69.808 uV, v_off_fin = -66.189 uV 15:16:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.856 uVs 15:16:55 Integrated Voltage Measurement... 15:17:04 Voltage Offset Correction: v_off_ini = -79.173 uV, v_off_fin = -80.467 uV 15:17:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.073 uVs 15:17:04 Integrated Voltage Measurement... 15:17:13 Voltage Offset Correction: v_off_ini = -75.157 uV, v_off_fin = -80.713 uV 15:17:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.741 uVs 15:17:15 I2Y Average and RMS of Measurements VT = -309.830 +- 4.870 uVs I2Y = -28.504 +- 0.448 uTm^2 15:17:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:30 Integrated Voltage Measurement... 15:17:39 Voltage Offset Correction: v_off_ini = -86.710 uV, v_off_fin = -96.857 uV 15:17:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.169 uVs 15:17:39 Integrated Voltage Measurement... 15:17:48 Voltage Offset Correction: v_off_ini = -98.637 uV, v_off_fin = -84.180 uV 15:17:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.198 uVs 15:17:48 Integrated Voltage Measurement... 15:17:57 Voltage Offset Correction: v_off_ini = -81.388 uV, v_off_fin = -85.102 uV 15:17:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.690 uVs 15:17:57 Integrated Voltage Measurement... 15:18:06 Voltage Offset Correction: v_off_ini = -87.427 uV, v_off_fin = -71.771 uV 15:18:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.568 uVs 15:18:06 Integrated Voltage Measurement... 15:18:15 Voltage Offset Correction: v_off_ini = -90.979 uV, v_off_fin = -91.083 uV 15:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.793 uVs 15:18:15 Integrated Voltage Measurement... 15:18:24 Voltage Offset Correction: v_off_ini = -90.801 uV, v_off_fin = -72.407 uV 15:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.924 uVs 15:18:28 I1X Average and RMS of Measurements VT = -75.890 +- 3.877 uVs I1X = 15.178 +- 0.776 uTm 15:18:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:35 Integrated Voltage Measurement... 15:18:44 Voltage Offset Correction: v_off_ini = -88.930 uV, v_off_fin = -92.675 uV 15:18:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.934 uVs 15:18:44 Integrated Voltage Measurement... 15:18:53 Voltage Offset Correction: v_off_ini = -85.020 uV, v_off_fin = -72.067 uV 15:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.345 uVs 15:18:53 Integrated Voltage Measurement... 15:19:02 Voltage Offset Correction: v_off_ini = -64.679 uV, v_off_fin = -60.577 uV 15:19:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.856 uVs 15:19:02 Integrated Voltage Measurement... 15:19:11 Voltage Offset Correction: v_off_ini = -53.805 uV, v_off_fin = -23.249 uV 15:19:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.519 uVs 15:19:11 Integrated Voltage Measurement... 15:19:20 Voltage Offset Correction: v_off_ini = -39.016 uV, v_off_fin = -55.581 uV 15:19:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -263.197 uVs 15:19:20 Integrated Voltage Measurement... 15:19:29 Voltage Offset Correction: v_off_ini = -48.929 uV, v_off_fin = -46.172 uV 15:19:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.518 uVs 15:19:33 I1Y Average and RMS of Measurements VT = -262.728 +- 1.929 uVs I1Y = -52.543 +- 0.385 uTm 15:19:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:41 Integrated Voltage Measurement... 15:19:50 Voltage Offset Correction: v_off_ini = -65.306 uV, v_off_fin = -81.239 uV 15:19:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.999 uVs 15:19:50 Integrated Voltage Measurement... 15:19:59 Voltage Offset Correction: v_off_ini = -72.971 uV, v_off_fin = -48.322 uV 15:19:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.486 uVs 15:19:59 Integrated Voltage Measurement... 15:20:08 Voltage Offset Correction: v_off_ini = -72.624 uV, v_off_fin = -54.899 uV 15:20:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.722 uVs 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = -48.429 uV, v_off_fin = -45.503 uV 15:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.206 uVs 15:20:17 Integrated Voltage Measurement... 15:20:26 Voltage Offset Correction: v_off_ini = -54.647 uV, v_off_fin = -66.329 uV 15:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.188 uVs 15:20:26 Integrated Voltage Measurement... 15:20:35 Voltage Offset Correction: v_off_ini = -60.159 uV, v_off_fin = -44.445 uV 15:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.762 uVs 15:20:37 I2X Average and RMS of Measurements VT = -89.394 +- 5.437 uVs I2X = 8.224 +- 0.500 uTm^2 15:20:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:45 Integrated Voltage Measurement... 15:20:54 Voltage Offset Correction: v_off_ini = -44.528 uV, v_off_fin = -52.466 uV 15:20:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.527 uVs 15:20:54 Integrated Voltage Measurement... 15:21:03 Voltage Offset Correction: v_off_ini = -46.917 uV, v_off_fin = -52.738 uV 15:21:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.244 uVs 15:21:03 Integrated Voltage Measurement... 15:21:12 Voltage Offset Correction: v_off_ini = -44.342 uV, v_off_fin = -51.913 uV 15:21:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.367 uVs 15:21:12 Integrated Voltage Measurement... 15:21:21 Voltage Offset Correction: v_off_ini = -51.659 uV, v_off_fin = -53.179 uV 15:21:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.703 uVs 15:21:21 Integrated Voltage Measurement... 15:21:30 Voltage Offset Correction: v_off_ini = -54.257 uV, v_off_fin = -52.504 uV 15:21:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.787 uVs 15:21:30 Integrated Voltage Measurement... 15:21:39 Voltage Offset Correction: v_off_ini = -43.826 uV, v_off_fin = -61.692 uV 15:21:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 317.585 uVs 15:21:41 I2Y Average and RMS of Measurements VT = -326.369 +- 5.169 uVs I2Y = -30.026 +- 0.476 uTm^2 15:21:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:56 Integrated Voltage Measurement... 15:22:05 Voltage Offset Correction: v_off_ini = -39.238 uV, v_off_fin = -48.807 uV 15:22:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.177 uVs 15:22:05 Integrated Voltage Measurement... 15:22:14 Voltage Offset Correction: v_off_ini = -34.342 uV, v_off_fin = -34.753 uV 15:22:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.806 uVs 15:22:14 Integrated Voltage Measurement... 15:22:23 Voltage Offset Correction: v_off_ini = -43.935 uV, v_off_fin = -41.510 uV 15:22:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.048 uVs 15:22:23 Integrated Voltage Measurement... 15:22:32 Voltage Offset Correction: v_off_ini = -42.219 uV, v_off_fin = -30.232 uV 15:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.684 uVs 15:22:32 Integrated Voltage Measurement... 15:22:41 Voltage Offset Correction: v_off_ini = -35.667 uV, v_off_fin = -49.607 uV 15:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.670 uVs 15:22:41 Integrated Voltage Measurement... 15:22:50 Voltage Offset Correction: v_off_ini = -38.128 uV, v_off_fin = -38.349 uV 15:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.110 uVs 15:22:55 I1X Average and RMS of Measurements VT = -78.249 +- 6.954 uVs I1X = 15.650 +- 1.391 uTm 15:22:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:01 Integrated Voltage Measurement... 15:23:10 Voltage Offset Correction: v_off_ini = -41.550 uV, v_off_fin = -38.250 uV 15:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -259.310 uVs 15:23:10 Integrated Voltage Measurement... 15:23:19 Voltage Offset Correction: v_off_ini = -12.711 uV, v_off_fin = -6.094 uV 15:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.740 uVs 15:23:19 Integrated Voltage Measurement... 15:23:28 Voltage Offset Correction: v_off_ini = -27.032 uV, v_off_fin = -33.372 uV 15:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -248.389 uVs 15:23:28 Integrated Voltage Measurement... 15:23:37 Voltage Offset Correction: v_off_ini = -17.087 uV, v_off_fin = 9.932 uV 15:23:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 260.299 uVs 15:23:37 Integrated Voltage Measurement... 15:23:46 Voltage Offset Correction: v_off_ini = 0.875 uV, v_off_fin = -18.454 uV 15:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -273.548 uVs 15:23:46 Integrated Voltage Measurement... 15:23:55 Voltage Offset Correction: v_off_ini = -2.152 uV, v_off_fin = 22.331 uV 15:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 261.452 uVs 15:23:59 I1Y Average and RMS of Measurements VT = -258.456 +- 6.404 uVs I1Y = -51.686 +- 1.281 uTm 15:24:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = 19.507 uV, v_off_fin = 10.717 uV 15:24:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -108.879 uVs 15:24:16 Integrated Voltage Measurement... 15:24:25 Voltage Offset Correction: v_off_ini = 15.509 uV, v_off_fin = 22.761 uV 15:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.136 uVs 15:24:25 Integrated Voltage Measurement... 15:24:34 Voltage Offset Correction: v_off_ini = 14.218 uV, v_off_fin = 15.180 uV 15:24:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.489 uVs 15:24:34 Integrated Voltage Measurement... 15:24:43 Voltage Offset Correction: v_off_ini = 28.566 uV, v_off_fin = 33.082 uV 15:24:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.103 uVs 15:24:43 Integrated Voltage Measurement... 15:24:52 Voltage Offset Correction: v_off_ini = 26.120 uV, v_off_fin = 26.101 uV 15:24:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.111 uVs 15:24:52 Integrated Voltage Measurement... 15:25:01 Voltage Offset Correction: v_off_ini = 43.706 uV, v_off_fin = 52.842 uV 15:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.798 uVs 15:25:04 I2X Average and RMS of Measurements VT = -94.419 +- 9.546 uVs I2X = 8.687 +- 0.878 uTm^2 15:25:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:11 Integrated Voltage Measurement... 15:25:20 Voltage Offset Correction: v_off_ini = 53.263 uV, v_off_fin = 44.147 uV 15:25:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.423 uVs 15:25:20 Integrated Voltage Measurement... 15:25:29 Voltage Offset Correction: v_off_ini = 44.908 uV, v_off_fin = 43.302 uV 15:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.296 uVs 15:25:29 Integrated Voltage Measurement... 15:25:38 Voltage Offset Correction: v_off_ini = 35.802 uV, v_off_fin = 42.500 uV 15:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.387 uVs 15:25:38 Integrated Voltage Measurement... 15:25:47 Voltage Offset Correction: v_off_ini = 49.596 uV, v_off_fin = 45.402 uV 15:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.155 uVs 15:25:47 Integrated Voltage Measurement... 15:25:56 Voltage Offset Correction: v_off_ini = 54.857 uV, v_off_fin = 58.230 uV 15:25:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.043 uVs 15:25:56 Integrated Voltage Measurement... 15:26:05 Voltage Offset Correction: v_off_ini = 45.887 uV, v_off_fin = 47.436 uV 15:26:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.940 uVs 15:26:08 I2Y Average and RMS of Measurements VT = -328.207 +- 6.638 uVs I2Y = -30.195 +- 0.611 uTm^2 15:26:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:24 Integrated Voltage Measurement... 15:26:33 Voltage Offset Correction: v_off_ini = 47.182 uV, v_off_fin = 50.475 uV 15:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.982 uVs 15:26:33 Integrated Voltage Measurement... 15:26:42 Voltage Offset Correction: v_off_ini = 51.441 uV, v_off_fin = 48.924 uV 15:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.704 uVs 15:26:42 Integrated Voltage Measurement... 15:26:51 Voltage Offset Correction: v_off_ini = 44.563 uV, v_off_fin = 29.922 uV 15:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.745 uVs 15:26:51 Integrated Voltage Measurement... 15:27:00 Voltage Offset Correction: v_off_ini = 24.303 uV, v_off_fin = 45.053 uV 15:27:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.688 uVs 15:27:00 Integrated Voltage Measurement... 15:27:09 Voltage Offset Correction: v_off_ini = 54.739 uV, v_off_fin = 49.041 uV 15:27:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.656 uVs 15:27:09 Integrated Voltage Measurement... 15:27:18 Voltage Offset Correction: v_off_ini = 49.319 uV, v_off_fin = 47.562 uV 15:27:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.563 uVs 15:27:22 I1X Average and RMS of Measurements VT = -90.057 +- 3.764 uVs I1X = 18.012 +- 0.753 uTm 15:27:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:29 Integrated Voltage Measurement... 15:27:38 Voltage Offset Correction: v_off_ini = 49.791 uV, v_off_fin = 31.133 uV 15:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -268.651 uVs 15:27:38 Integrated Voltage Measurement... 15:27:47 Voltage Offset Correction: v_off_ini = 59.930 uV, v_off_fin = 70.335 uV 15:27:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 285.979 uVs 15:27:47 Integrated Voltage Measurement... 15:27:56 Voltage Offset Correction: v_off_ini = 71.213 uV, v_off_fin = 47.812 uV 15:27:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -267.726 uVs 15:27:56 Integrated Voltage Measurement... 15:28:05 Voltage Offset Correction: v_off_ini = 48.776 uV, v_off_fin = 70.176 uV 15:28:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.057 uVs 15:28:05 Integrated Voltage Measurement... 15:28:14 Voltage Offset Correction: v_off_ini = 59.379 uV, v_off_fin = 62.027 uV 15:28:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -275.434 uVs 15:28:14 Integrated Voltage Measurement... 15:28:23 Voltage Offset Correction: v_off_ini = 69.930 uV, v_off_fin = 89.058 uV 15:28:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 264.029 uVs 15:28:27 I1Y Average and RMS of Measurements VT = -269.646 +- 6.297 uVs I1Y = -53.923 +- 1.258 uTm 15:28:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:34 Integrated Voltage Measurement... 15:28:43 Voltage Offset Correction: v_off_ini = 58.381 uV, v_off_fin = 51.321 uV 15:28:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.926 uVs 15:28:43 Integrated Voltage Measurement... 15:28:52 Voltage Offset Correction: v_off_ini = 67.567 uV, v_off_fin = 77.783 uV 15:28:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.026 uVs 15:28:53 Integrated Voltage Measurement... 15:29:01 Voltage Offset Correction: v_off_ini = 68.700 uV, v_off_fin = 54.500 uV 15:29:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.078 uVs 15:29:02 Integrated Voltage Measurement... 15:29:10 Voltage Offset Correction: v_off_ini = 68.155 uV, v_off_fin = 74.420 uV 15:29:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.345 uVs 15:29:11 Integrated Voltage Measurement... 15:29:20 Voltage Offset Correction: v_off_ini = 76.667 uV, v_off_fin = 52.339 uV 15:29:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.472 uVs 15:29:20 Integrated Voltage Measurement... 15:29:29 Voltage Offset Correction: v_off_ini = 73.711 uV, v_off_fin = 79.777 uV 15:29:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.802 uVs 15:29:31 I2X Average and RMS of Measurements VT = -96.608 +- 3.392 uVs I2X = 8.888 +- 0.312 uTm^2 15:29:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:39 Integrated Voltage Measurement... 15:29:48 Voltage Offset Correction: v_off_ini = 75.809 uV, v_off_fin = 80.730 uV 15:29:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.533 uVs 15:29:48 Integrated Voltage Measurement... 15:29:57 Voltage Offset Correction: v_off_ini = 73.421 uV, v_off_fin = 86.345 uV 15:29:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.423 uVs 15:29:57 Integrated Voltage Measurement... 15:30:06 Voltage Offset Correction: v_off_ini = 85.497 uV, v_off_fin = 94.194 uV 15:30:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.810 uVs 15:30:06 Integrated Voltage Measurement... 15:30:15 Voltage Offset Correction: v_off_ini = 91.474 uV, v_off_fin = 92.237 uV 15:30:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.176 uVs 15:30:15 Integrated Voltage Measurement... 15:30:24 Voltage Offset Correction: v_off_ini = 90.382 uV, v_off_fin = 81.156 uV 15:30:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.723 uVs 15:30:24 Integrated Voltage Measurement... 15:30:33 Voltage Offset Correction: v_off_ini = 77.672 uV, v_off_fin = 83.519 uV 15:30:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.767 uVs 15:30:35 I2Y Average and RMS of Measurements VT = -330.905 +- 6.490 uVs I2Y = -30.443 +- 0.597 uTm^2 15:30:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:50 Integrated Voltage Measurement... 15:30:59 Voltage Offset Correction: v_off_ini = 68.745 uV, v_off_fin = 66.240 uV 15:30:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.700 uVs 15:30:59 Integrated Voltage Measurement... 15:31:08 Voltage Offset Correction: v_off_ini = 72.968 uV, v_off_fin = 70.561 uV 15:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.116 uVs 15:31:08 Integrated Voltage Measurement... 15:31:17 Voltage Offset Correction: v_off_ini = 71.710 uV, v_off_fin = 63.732 uV 15:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.662 uVs 15:31:17 Integrated Voltage Measurement... 15:31:26 Voltage Offset Correction: v_off_ini = 67.427 uV, v_off_fin = 67.630 uV 15:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.334 uVs 15:31:26 Integrated Voltage Measurement... 15:31:35 Voltage Offset Correction: v_off_ini = 77.444 uV, v_off_fin = 71.179 uV 15:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.629 uVs 15:31:35 Integrated Voltage Measurement... 15:31:44 Voltage Offset Correction: v_off_ini = 81.551 uV, v_off_fin = 80.955 uV 15:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.292 uVs 15:31:48 I1X Average and RMS of Measurements VT = -89.289 +- 3.825 uVs I1X = 17.858 +- 0.765 uTm 15:31:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:55 Integrated Voltage Measurement... 15:32:04 Voltage Offset Correction: v_off_ini = 95.156 uV, v_off_fin = 88.071 uV 15:32:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.732 uVs 15:32:04 Integrated Voltage Measurement... 15:32:13 Voltage Offset Correction: v_off_ini = 90.163 uV, v_off_fin = 96.574 uV 15:32:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 270.016 uVs 15:32:13 Integrated Voltage Measurement... 15:32:22 Voltage Offset Correction: v_off_ini = 89.427 uV, v_off_fin = 74.125 uV 15:32:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -288.382 uVs 15:32:22 Integrated Voltage Measurement... 15:32:31 Voltage Offset Correction: v_off_ini = 85.091 uV, v_off_fin = 101.461 uV 15:32:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 275.853 uVs 15:32:31 Integrated Voltage Measurement... 15:32:40 Voltage Offset Correction: v_off_ini = 94.206 uV, v_off_fin = 94.484 uV 15:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -267.715 uVs 15:32:40 Integrated Voltage Measurement... 15:32:49 Voltage Offset Correction: v_off_ini = 94.461 uV, v_off_fin = 111.177 uV 15:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 288.901 uVs 15:32:53 I1Y Average and RMS of Measurements VT = -277.933 +- 3.579 uVs I1Y = -55.580 +- 0.715 uTm 15:32:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:01 Integrated Voltage Measurement... 15:33:10 Voltage Offset Correction: v_off_ini = 84.314 uV, v_off_fin = 86.623 uV 15:33:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.552 uVs 15:33:10 Integrated Voltage Measurement... 15:33:19 Voltage Offset Correction: v_off_ini = 99.816 uV, v_off_fin = 107.145 uV 15:33:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.715 uVs 15:33:19 Integrated Voltage Measurement... 15:33:28 Voltage Offset Correction: v_off_ini = 97.630 uV, v_off_fin = 93.395 uV 15:33:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.235 uVs 15:33:28 Integrated Voltage Measurement... 15:33:37 Voltage Offset Correction: v_off_ini = 97.001 uV, v_off_fin = 100.474 uV 15:33:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.425 uVs 15:33:37 Integrated Voltage Measurement... 15:33:46 Voltage Offset Correction: v_off_ini = 89.383 uV, v_off_fin = 85.595 uV 15:33:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -98.954 uVs 15:33:46 Integrated Voltage Measurement... 15:33:55 Voltage Offset Correction: v_off_ini = 88.563 uV, v_off_fin = 113.938 uV 15:33:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.560 uVs 15:33:57 I2X Average and RMS of Measurements VT = -101.073 +- 12.124 uVs I2X = 9.299 +- 1.115 uTm^2 15:34:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:05 Integrated Voltage Measurement... 15:34:14 Voltage Offset Correction: v_off_ini = 102.905 uV, v_off_fin = 101.676 uV 15:34:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.772 uVs 15:34:14 Integrated Voltage Measurement... 15:34:23 Voltage Offset Correction: v_off_ini = 100.345 uV, v_off_fin = 101.048 uV 15:34:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.118 uVs 15:34:23 Integrated Voltage Measurement... 15:34:32 Voltage Offset Correction: v_off_ini = 116.998 uV, v_off_fin = 119.618 uV 15:34:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.047 uVs 15:34:32 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = 103.975 uV, v_off_fin = 117.263 uV 15:34:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 332.042 uVs 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = 109.187 uV, v_off_fin = 109.548 uV 15:34:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -338.062 uVs 15:34:50 Integrated Voltage Measurement... 15:34:59 Voltage Offset Correction: v_off_ini = 111.156 uV, v_off_fin = 106.699 uV 15:34:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.871 uVs 15:35:02 I2Y Average and RMS of Measurements VT = -337.819 +- 7.295 uVs I2Y = -31.080 +- 0.670 uTm^2 15:35:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:19 Integrated Voltage Measurement... 15:35:28 Voltage Offset Correction: v_off_ini = 117.964 uV, v_off_fin = 106.452 uV 15:35:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.960 uVs 15:35:28 Integrated Voltage Measurement... 15:35:37 Voltage Offset Correction: v_off_ini = 128.408 uV, v_off_fin = 125.919 uV 15:35:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.298 uVs 15:35:37 Integrated Voltage Measurement... 15:35:46 Voltage Offset Correction: v_off_ini = 130.856 uV, v_off_fin = 128.290 uV 15:35:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.781 uVs 15:35:46 Integrated Voltage Measurement... 15:35:55 Voltage Offset Correction: v_off_ini = 134.484 uV, v_off_fin = 139.771 uV 15:35:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.218 uVs 15:35:55 Integrated Voltage Measurement... 15:36:04 Voltage Offset Correction: v_off_ini = 133.866 uV, v_off_fin = 118.448 uV 15:36:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.532 uVs 15:36:04 Integrated Voltage Measurement... 15:36:13 Voltage Offset Correction: v_off_ini = 130.252 uV, v_off_fin = 125.344 uV 15:36:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.148 uVs 15:36:17 I1X Average and RMS of Measurements VT = -87.323 +- 10.276 uVs I1X = 17.465 +- 2.055 uTm 15:36:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:24 Integrated Voltage Measurement... 15:36:33 Voltage Offset Correction: v_off_ini = 131.208 uV, v_off_fin = 117.111 uV 15:36:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.828 uVs 15:36:33 Integrated Voltage Measurement... 15:36:42 Voltage Offset Correction: v_off_ini = 123.762 uV, v_off_fin = 133.213 uV 15:36:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 273.449 uVs 15:36:42 Integrated Voltage Measurement... 15:36:51 Voltage Offset Correction: v_off_ini = 124.856 uV, v_off_fin = 122.236 uV 15:36:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.635 uVs 15:36:51 Integrated Voltage Measurement... 15:37:00 Voltage Offset Correction: v_off_ini = 134.435 uV, v_off_fin = 134.550 uV 15:37:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 286.561 uVs 15:37:00 Integrated Voltage Measurement... 15:37:09 Voltage Offset Correction: v_off_ini = 120.716 uV, v_off_fin = 121.852 uV 15:37:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.551 uVs 15:37:09 Integrated Voltage Measurement... 15:37:18 Voltage Offset Correction: v_off_ini = 139.014 uV, v_off_fin = 146.479 uV 15:37:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.404 uVs 15:37:22 I1Y Average and RMS of Measurements VT = -275.071 +- 1.441 uVs I1Y = -55.012 +- 0.288 uTm 15:37:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:30 Integrated Voltage Measurement... 15:37:38 Voltage Offset Correction: v_off_ini = 133.506 uV, v_off_fin = 120.586 uV 15:37:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.288 uVs 15:37:39 Integrated Voltage Measurement... 15:37:48 Voltage Offset Correction: v_off_ini = 129.641 uV, v_off_fin = 140.095 uV 15:37:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.278 uVs 15:37:48 Integrated Voltage Measurement... 15:37:57 Voltage Offset Correction: v_off_ini = 122.913 uV, v_off_fin = 120.039 uV 15:37:57 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -93.853 uVs 15:37:57 Integrated Voltage Measurement... 15:38:06 Voltage Offset Correction: v_off_ini = 133.130 uV, v_off_fin = 143.074 uV 15:38:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.890 uVs 15:38:06 Integrated Voltage Measurement... 15:38:15 Voltage Offset Correction: v_off_ini = 126.734 uV, v_off_fin = 130.452 uV 15:38:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.583 uVs 15:38:15 Integrated Voltage Measurement... 15:38:24 Voltage Offset Correction: v_off_ini = 141.521 uV, v_off_fin = 151.181 uV 15:38:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.301 uVs 15:38:26 I2X Average and RMS of Measurements VT = -94.199 +- 5.614 uVs I2X = 8.667 +- 0.516 uTm^2 15:38:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:34 Integrated Voltage Measurement... 15:38:43 Voltage Offset Correction: v_off_ini = 140.128 uV, v_off_fin = 145.540 uV 15:38:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.257 uVs 15:38:43 Integrated Voltage Measurement... 15:38:52 Voltage Offset Correction: v_off_ini = 133.766 uV, v_off_fin = 141.678 uV 15:38:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.698 uVs 15:38:52 Integrated Voltage Measurement... 15:39:01 Voltage Offset Correction: v_off_ini = 151.609 uV, v_off_fin = 145.725 uV 15:39:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.917 uVs 15:39:01 Integrated Voltage Measurement... 15:39:10 Voltage Offset Correction: v_off_ini = 152.442 uV, v_off_fin = 168.386 uV 15:39:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.672 uVs 15:39:10 Integrated Voltage Measurement... 15:39:19 Voltage Offset Correction: v_off_ini = 150.333 uV, v_off_fin = 160.262 uV 15:39:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.517 uVs 15:39:19 Integrated Voltage Measurement... 15:39:28 Voltage Offset Correction: v_off_ini = 161.121 uV, v_off_fin = 165.418 uV 15:39:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.598 uVs 15:39:30 I2Y Average and RMS of Measurements VT = -339.776 +- 4.391 uVs I2Y = -31.259 +- 0.404 uTm^2 15:39:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:46 Integrated Voltage Measurement... 15:39:55 Voltage Offset Correction: v_off_ini = 169.062 uV, v_off_fin = 156.239 uV 15:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.474 uVs 15:39:55 Integrated Voltage Measurement... 15:40:04 Voltage Offset Correction: v_off_ini = 171.362 uV, v_off_fin = 167.041 uV 15:40:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.929 uVs 15:40:04 Integrated Voltage Measurement... 15:40:13 Voltage Offset Correction: v_off_ini = 158.018 uV, v_off_fin = 157.691 uV 15:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.404 uVs 15:40:13 Integrated Voltage Measurement... 15:40:22 Voltage Offset Correction: v_off_ini = 154.510 uV, v_off_fin = 155.196 uV 15:40:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.441 uVs 15:40:22 Integrated Voltage Measurement... 15:40:31 Voltage Offset Correction: v_off_ini = 166.903 uV, v_off_fin = 161.153 uV 15:40:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.828 uVs 15:40:31 Integrated Voltage Measurement... 15:40:40 Voltage Offset Correction: v_off_ini = 172.277 uV, v_off_fin = 180.185 uV 15:40:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.294 uVs 15:40:44 I1X Average and RMS of Measurements VT = -83.228 +- 6.274 uVs I1X = 16.646 +- 1.255 uTm 15:40:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:51 Integrated Voltage Measurement... 15:41:00 Voltage Offset Correction: v_off_ini = 154.286 uV, v_off_fin = 145.659 uV 15:41:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -257.888 uVs 15:41:00 Integrated Voltage Measurement... 15:41:09 Voltage Offset Correction: v_off_ini = 160.133 uV, v_off_fin = 167.587 uV 15:41:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.151 uVs 15:41:09 Integrated Voltage Measurement... 15:41:18 Voltage Offset Correction: v_off_ini = 154.959 uV, v_off_fin = 149.120 uV 15:41:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.939 uVs 15:41:18 Integrated Voltage Measurement... 15:41:27 Voltage Offset Correction: v_off_ini = 149.924 uV, v_off_fin = 156.819 uV 15:41:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.832 uVs 15:41:27 Integrated Voltage Measurement... 15:41:36 Voltage Offset Correction: v_off_ini = 152.880 uV, v_off_fin = 138.081 uV 15:41:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.960 uVs 15:41:36 Integrated Voltage Measurement... 15:41:45 Voltage Offset Correction: v_off_ini = 151.868 uV, v_off_fin = 165.032 uV 15:41:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.885 uVs 15:41:49 I1Y Average and RMS of Measurements VT = -270.276 +- 3.967 uVs I1Y = -54.056 +- 0.793 uTm 15:41:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:57 Integrated Voltage Measurement... 15:42:06 Voltage Offset Correction: v_off_ini = 152.283 uV, v_off_fin = 146.814 uV 15:42:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -101.894 uVs 15:42:06 Integrated Voltage Measurement... 15:42:15 Voltage Offset Correction: v_off_ini = 143.605 uV, v_off_fin = 176.341 uV 15:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.267 uVs 15:42:15 Integrated Voltage Measurement... 15:42:24 Voltage Offset Correction: v_off_ini = 166.523 uV, v_off_fin = 157.938 uV 15:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.070 uVs 15:42:24 Integrated Voltage Measurement... 15:42:33 Voltage Offset Correction: v_off_ini = 163.418 uV, v_off_fin = 172.741 uV 15:42:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.420 uVs 15:42:33 Integrated Voltage Measurement... 15:42:42 Voltage Offset Correction: v_off_ini = 160.649 uV, v_off_fin = 147.998 uV 15:42:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.332 uVs 15:42:42 Integrated Voltage Measurement... 15:42:51 Voltage Offset Correction: v_off_ini = 155.612 uV, v_off_fin = 162.660 uV 15:42:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.342 uVs 15:42:53 I2X Average and RMS of Measurements VT = -91.554 +- 9.072 uVs I2X = 8.423 +- 0.834 uTm^2 15:42:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:01 Integrated Voltage Measurement... 15:43:10 Voltage Offset Correction: v_off_ini = 143.554 uV, v_off_fin = 147.488 uV 15:43:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.022 uVs 15:43:10 Integrated Voltage Measurement... 15:43:19 Voltage Offset Correction: v_off_ini = 147.718 uV, v_off_fin = 138.321 uV 15:43:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.271 uVs 15:43:19 Integrated Voltage Measurement... 15:43:28 Voltage Offset Correction: v_off_ini = 148.006 uV, v_off_fin = 140.654 uV 15:43:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.452 uVs 15:43:28 Integrated Voltage Measurement... 15:43:37 Voltage Offset Correction: v_off_ini = 147.364 uV, v_off_fin = 149.958 uV 15:43:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.279 uVs 15:43:37 Integrated Voltage Measurement... 15:43:46 Voltage Offset Correction: v_off_ini = 138.521 uV, v_off_fin = 142.957 uV 15:43:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.819 uVs 15:43:46 Integrated Voltage Measurement... 15:43:55 Voltage Offset Correction: v_off_ini = 151.601 uV, v_off_fin = 158.698 uV 15:43:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.091 uVs 15:43:57 I2Y Average and RMS of Measurements VT = -332.656 +- 9.644 uVs I2Y = -30.604 +- 0.887 uTm^2 15:44:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:16 Integrated Voltage Measurement... 15:44:25 Voltage Offset Correction: v_off_ini = 139.727 uV, v_off_fin = 136.389 uV 15:44:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.199 uVs 15:44:25 Integrated Voltage Measurement... 15:44:34 Voltage Offset Correction: v_off_ini = 138.321 uV, v_off_fin = 140.191 uV 15:44:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.487 uVs 15:44:34 Integrated Voltage Measurement... 15:44:43 Voltage Offset Correction: v_off_ini = 138.986 uV, v_off_fin = 133.936 uV 15:44:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.397 uVs 15:44:43 Integrated Voltage Measurement... 15:44:52 Voltage Offset Correction: v_off_ini = 133.277 uV, v_off_fin = 133.744 uV 15:44:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.053 uVs 15:44:52 Integrated Voltage Measurement... 15:45:01 Voltage Offset Correction: v_off_ini = 129.765 uV, v_off_fin = 121.942 uV 15:45:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.724 uVs 15:45:01 Integrated Voltage Measurement... 15:45:10 Voltage Offset Correction: v_off_ini = 127.086 uV, v_off_fin = 135.254 uV 15:45:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.355 uVs 15:45:14 I1X Average and RMS of Measurements VT = -95.202 +- 2.766 uVs I1X = 19.041 +- 0.553 uTm 15:45:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:21 Integrated Voltage Measurement... 15:45:30 Voltage Offset Correction: v_off_ini = 151.931 uV, v_off_fin = 130.357 uV 15:45:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -264.541 uVs 15:45:30 Integrated Voltage Measurement... 15:45:38 Voltage Offset Correction: v_off_ini = 158.041 uV, v_off_fin = 182.594 uV 15:45:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.406 uVs 15:45:39 Integrated Voltage Measurement... 15:45:47 Voltage Offset Correction: v_off_ini = 162.756 uV, v_off_fin = 153.516 uV 15:45:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.573 uVs 15:45:48 Integrated Voltage Measurement... 15:45:56 Voltage Offset Correction: v_off_ini = 178.873 uV, v_off_fin = 178.983 uV 15:45:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.405 uVs 15:45:56 Integrated Voltage Measurement... 15:46:05 Voltage Offset Correction: v_off_ini = 182.773 uV, v_off_fin = 168.633 uV 15:46:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -268.864 uVs 15:46:05 Integrated Voltage Measurement... 15:46:14 Voltage Offset Correction: v_off_ini = 172.749 uV, v_off_fin = 201.512 uV 15:46:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 264.630 uVs 15:46:19 I1Y Average and RMS of Measurements VT = -264.570 +- 4.357 uVs I1Y = -52.910 +- 0.872 uTm 15:46:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:26 Integrated Voltage Measurement... 15:46:35 Voltage Offset Correction: v_off_ini = 185.661 uV, v_off_fin = 185.398 uV 15:46:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -101.930 uVs 15:46:35 Integrated Voltage Measurement... 15:46:44 Voltage Offset Correction: v_off_ini = 189.878 uV, v_off_fin = 201.558 uV 15:46:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.154 uVs 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = 195.132 uV, v_off_fin = 179.413 uV 15:46:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.628 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = 196.152 uV, v_off_fin = 207.563 uV 15:47:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.110 uVs 15:47:02 Integrated Voltage Measurement... 15:47:11 Voltage Offset Correction: v_off_ini = 194.703 uV, v_off_fin = 191.710 uV 15:47:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.393 uVs 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 193.968 uV, v_off_fin = 201.908 uV 15:47:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.201 uVs 15:47:23 I2X Average and RMS of Measurements VT = -95.569 +- 5.234 uVs I2X = 8.793 +- 0.481 uTm^2 15:47:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:30 Integrated Voltage Measurement... 15:47:39 Voltage Offset Correction: v_off_ini = 214.967 uV, v_off_fin = 199.605 uV 15:47:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.875 uVs 15:47:39 Integrated Voltage Measurement... 15:47:48 Voltage Offset Correction: v_off_ini = 201.050 uV, v_off_fin = 212.467 uV 15:47:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.806 uVs 15:47:48 Integrated Voltage Measurement... 15:47:57 Voltage Offset Correction: v_off_ini = 219.485 uV, v_off_fin = 207.218 uV 15:47:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.626 uVs 15:47:57 Integrated Voltage Measurement... 15:48:06 Voltage Offset Correction: v_off_ini = 212.157 uV, v_off_fin = 205.907 uV 15:48:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.397 uVs 15:48:06 Integrated Voltage Measurement... 15:48:15 Voltage Offset Correction: v_off_ini = 214.152 uV, v_off_fin = 213.643 uV 15:48:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.206 uVs 15:48:15 Integrated Voltage Measurement... 15:48:24 Voltage Offset Correction: v_off_ini = 205.473 uV, v_off_fin = 205.058 uV 15:48:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.174 uVs 15:48:27 I2Y Average and RMS of Measurements VT = -318.348 +- 1.794 uVs I2Y = -29.288 +- 0.165 uTm^2 15:48:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:45 Integrated Voltage Measurement... 15:48:54 Voltage Offset Correction: v_off_ini = 207.189 uV, v_off_fin = 206.706 uV 15:48:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.950 uVs 15:48:54 Integrated Voltage Measurement... 15:49:03 Voltage Offset Correction: v_off_ini = 202.849 uV, v_off_fin = 205.425 uV 15:49:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.080 uVs 15:49:03 Integrated Voltage Measurement... 15:49:12 Voltage Offset Correction: v_off_ini = 201.099 uV, v_off_fin = 202.223 uV 15:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.720 uVs 15:49:12 Integrated Voltage Measurement... 15:49:21 Voltage Offset Correction: v_off_ini = 195.262 uV, v_off_fin = 201.956 uV 15:49:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.651 uVs 15:49:21 Integrated Voltage Measurement... 15:49:30 Voltage Offset Correction: v_off_ini = 189.967 uV, v_off_fin = 188.644 uV 15:49:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.574 uVs 15:49:30 Integrated Voltage Measurement... 15:49:39 Voltage Offset Correction: v_off_ini = 185.446 uV, v_off_fin = 192.378 uV 15:49:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.268 uVs 15:49:43 I1X Average and RMS of Measurements VT = -86.707 +- 1.567 uVs I1X = 17.341 +- 0.313 uTm 15:49:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:50 Integrated Voltage Measurement... 15:49:59 Voltage Offset Correction: v_off_ini = 204.659 uV, v_off_fin = 183.933 uV 15:49:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -262.186 uVs 15:49:59 Integrated Voltage Measurement... 15:50:08 Voltage Offset Correction: v_off_ini = 186.236 uV, v_off_fin = 200.051 uV 15:50:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 248.720 uVs 15:50:08 Integrated Voltage Measurement... 15:50:17 Voltage Offset Correction: v_off_ini = 178.968 uV, v_off_fin = 164.627 uV 15:50:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -264.779 uVs 15:50:17 Integrated Voltage Measurement... 15:50:26 Voltage Offset Correction: v_off_ini = 189.895 uV, v_off_fin = 201.401 uV 15:50:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.934 uVs 15:50:26 Integrated Voltage Measurement... 15:50:35 Voltage Offset Correction: v_off_ini = 194.211 uV, v_off_fin = 174.366 uV 15:50:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -265.468 uVs 15:50:35 Integrated Voltage Measurement... 15:50:44 Voltage Offset Correction: v_off_ini = 200.478 uV, v_off_fin = 199.197 uV 15:50:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 244.553 uVs 15:50:48 I1Y Average and RMS of Measurements VT = -256.773 +- 2.188 uVs I1Y = -51.351 +- 0.436 uTm 15:50:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:56 Integrated Voltage Measurement... 15:51:05 Voltage Offset Correction: v_off_ini = 196.254 uV, v_off_fin = 191.999 uV 15:51:05 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.214 uVs 15:51:05 Integrated Voltage Measurement... 15:51:14 Voltage Offset Correction: v_off_ini = 210.701 uV, v_off_fin = 219.316 uV 15:51:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.288 uVs 15:51:14 Integrated Voltage Measurement... 15:51:23 Voltage Offset Correction: v_off_ini = 195.947 uV, v_off_fin = 194.761 uV 15:51:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.586 uVs 15:51:23 Integrated Voltage Measurement... 15:51:32 Voltage Offset Correction: v_off_ini = 199.718 uV, v_off_fin = 206.024 uV 15:51:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.775 uVs 15:51:32 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = 186.405 uV, v_off_fin = 180.912 uV 15:51:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.469 uVs 15:51:41 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = 192.960 uV, v_off_fin = 205.701 uV 15:51:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.420 uVs 15:51:52 I2X Average and RMS of Measurements VT = -93.459 +- 6.227 uVs I2X = 8.598 +- 0.573 uTm^2 15:51:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:00 Integrated Voltage Measurement... 15:52:09 Voltage Offset Correction: v_off_ini = 193.390 uV, v_off_fin = 201.098 uV 15:52:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.701 uVs 15:52:09 Integrated Voltage Measurement... 15:52:18 Voltage Offset Correction: v_off_ini = 219.477 uV, v_off_fin = 222.166 uV 15:52:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.661 uVs 15:52:18 Integrated Voltage Measurement... 15:52:27 Voltage Offset Correction: v_off_ini = 218.686 uV, v_off_fin = 216.001 uV 15:52:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.891 uVs 15:52:27 Integrated Voltage Measurement... 15:52:36 Voltage Offset Correction: v_off_ini = 221.875 uV, v_off_fin = 221.431 uV 15:52:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.301 uVs 15:52:36 Integrated Voltage Measurement... 15:52:45 Voltage Offset Correction: v_off_ini = 217.006 uV, v_off_fin = 210.237 uV 15:52:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.582 uVs 15:52:45 Integrated Voltage Measurement... 15:52:54 Voltage Offset Correction: v_off_ini = 218.418 uV, v_off_fin = 212.287 uV 15:52:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.989 uVs 15:52:56 I2Y Average and RMS of Measurements VT = -293.521 +- 2.874 uVs I2Y = -27.004 +- 0.264 uTm^2 15:53:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:15 Integrated Voltage Measurement... 15:53:24 Voltage Offset Correction: v_off_ini = 219.938 uV, v_off_fin = 211.092 uV 15:53:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.232 uVs 15:53:24 Integrated Voltage Measurement... 15:53:33 Voltage Offset Correction: v_off_ini = 209.088 uV, v_off_fin = 235.952 uV 15:53:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.168 uVs 15:53:33 Integrated Voltage Measurement... 15:53:42 Voltage Offset Correction: v_off_ini = 225.783 uV, v_off_fin = 226.123 uV 15:53:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.391 uVs 15:53:42 Integrated Voltage Measurement... 15:53:51 Voltage Offset Correction: v_off_ini = 229.030 uV, v_off_fin = 234.742 uV 15:53:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.569 uVs 15:53:51 Integrated Voltage Measurement... 15:54:00 Voltage Offset Correction: v_off_ini = 237.847 uV, v_off_fin = 231.907 uV 15:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.157 uVs 15:54:00 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = 221.640 uV, v_off_fin = 232.636 uV 15:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.564 uVs 15:54:13 I1X Average and RMS of Measurements VT = -87.014 +- 7.938 uVs I1X = 17.403 +- 1.588 uTm 15:54:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:20 Integrated Voltage Measurement... 15:54:29 Voltage Offset Correction: v_off_ini = 225.273 uV, v_off_fin = 230.031 uV 15:54:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -237.668 uVs 15:54:29 Integrated Voltage Measurement... 15:54:38 Voltage Offset Correction: v_off_ini = 233.705 uV, v_off_fin = 254.855 uV 15:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 239.888 uVs 15:54:38 Integrated Voltage Measurement... 15:54:47 Voltage Offset Correction: v_off_ini = 248.385 uV, v_off_fin = 228.665 uV 15:54:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.254 uVs 15:54:47 Integrated Voltage Measurement... 15:54:56 Voltage Offset Correction: v_off_ini = 250.706 uV, v_off_fin = 250.296 uV 15:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.135 uVs 15:54:56 Integrated Voltage Measurement... 15:55:05 Voltage Offset Correction: v_off_ini = 237.417 uV, v_off_fin = 231.616 uV 15:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -244.158 uVs 15:55:05 Integrated Voltage Measurement... 15:55:14 Voltage Offset Correction: v_off_ini = 250.098 uV, v_off_fin = 264.561 uV 15:55:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.192 uVs 15:55:18 I1Y Average and RMS of Measurements VT = -243.549 +- 3.380 uVs I1Y = -48.707 +- 0.674 uTm 15:55:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:25 Integrated Voltage Measurement... 15:55:34 Voltage Offset Correction: v_off_ini = 260.922 uV, v_off_fin = 252.783 uV 15:55:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -98.376 uVs 15:55:34 Integrated Voltage Measurement... 15:55:43 Voltage Offset Correction: v_off_ini = 271.006 uV, v_off_fin = 287.648 uV 15:55:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.980 uVs 15:55:44 Integrated Voltage Measurement... 15:55:52 Voltage Offset Correction: v_off_ini = 276.002 uV, v_off_fin = 256.306 uV 15:55:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.988 uVs 15:55:53 Integrated Voltage Measurement... 15:56:01 Voltage Offset Correction: v_off_ini = 258.958 uV, v_off_fin = 266.215 uV 15:56:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.288 uVs 15:56:02 Integrated Voltage Measurement... 15:56:11 Voltage Offset Correction: v_off_ini = 257.674 uV, v_off_fin = 255.606 uV 15:56:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.874 uVs 15:56:11 Integrated Voltage Measurement... 15:56:20 Voltage Offset Correction: v_off_ini = 259.261 uV, v_off_fin = 273.894 uV 15:56:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.319 uVs 15:56:22 I2X Average and RMS of Measurements VT = -84.138 +- 7.182 uVs I2X = 7.741 +- 0.660 uTm^2 15:56:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:30 Integrated Voltage Measurement... 15:56:39 Voltage Offset Correction: v_off_ini = 259.941 uV, v_off_fin = 265.321 uV 15:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.402 uVs 15:56:39 Integrated Voltage Measurement... 15:56:48 Voltage Offset Correction: v_off_ini = 263.226 uV, v_off_fin = 264.971 uV 15:56:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.201 uVs 15:56:48 Integrated Voltage Measurement... 15:56:57 Voltage Offset Correction: v_off_ini = 256.655 uV, v_off_fin = 260.102 uV 15:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.812 uVs 15:56:57 Integrated Voltage Measurement... 15:57:06 Voltage Offset Correction: v_off_ini = 259.105 uV, v_off_fin = 264.241 uV 15:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.904 uVs 15:57:06 Integrated Voltage Measurement... 15:57:15 Voltage Offset Correction: v_off_ini = 258.797 uV, v_off_fin = 266.014 uV 15:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.086 uVs 15:57:15 Integrated Voltage Measurement... 15:57:24 Voltage Offset Correction: v_off_ini = 260.916 uV, v_off_fin = 259.164 uV 15:57:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.302 uVs 15:57:26 I2Y Average and RMS of Measurements VT = -288.951 +- 9.854 uVs I2Y = -26.584 +- 0.907 uTm^2 15:57:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:45 Integrated Voltage Measurement... 15:57:53 Voltage Offset Correction: v_off_ini = 256.380 uV, v_off_fin = 243.561 uV 15:57:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.728 uVs 15:57:54 Integrated Voltage Measurement... 15:58:02 Voltage Offset Correction: v_off_ini = 251.077 uV, v_off_fin = 253.645 uV 15:58:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.527 uVs 15:58:03 Integrated Voltage Measurement... 15:58:11 Voltage Offset Correction: v_off_ini = 264.819 uV, v_off_fin = 259.297 uV 15:58:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.530 uVs 15:58:12 Integrated Voltage Measurement... 15:58:20 Voltage Offset Correction: v_off_ini = 252.289 uV, v_off_fin = 268.117 uV 15:58:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 80.732 uVs 15:58:21 Integrated Voltage Measurement... 15:58:29 Voltage Offset Correction: v_off_ini = 266.839 uV, v_off_fin = 259.139 uV 15:58:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.245 uVs 15:58:30 Integrated Voltage Measurement... 15:58:38 Voltage Offset Correction: v_off_ini = 263.899 uV, v_off_fin = 252.812 uV 15:58:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.888 uVs 15:58:43 I1X Average and RMS of Measurements VT = -83.775 +- 8.447 uVs I1X = 16.756 +- 1.689 uTm 15:58:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:50 Integrated Voltage Measurement... 15:58:58 Voltage Offset Correction: v_off_ini = 244.859 uV, v_off_fin = 246.564 uV 15:58:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.595 uVs 15:58:58 Integrated Voltage Measurement... 15:59:07 Voltage Offset Correction: v_off_ini = 244.857 uV, v_off_fin = 264.040 uV 15:59:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 228.254 uVs 15:59:07 Integrated Voltage Measurement... 15:59:16 Voltage Offset Correction: v_off_ini = 261.452 uV, v_off_fin = 243.087 uV 15:59:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -232.681 uVs 15:59:16 Integrated Voltage Measurement... 15:59:25 Voltage Offset Correction: v_off_ini = 245.941 uV, v_off_fin = 275.218 uV 15:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.959 uVs 15:59:25 Integrated Voltage Measurement... 15:59:34 Voltage Offset Correction: v_off_ini = 242.412 uV, v_off_fin = 250.445 uV 15:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -239.559 uVs 15:59:34 Integrated Voltage Measurement... 15:59:43 Voltage Offset Correction: v_off_ini = 259.385 uV, v_off_fin = 285.312 uV 15:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.380 uVs 15:59:48 I1Y Average and RMS of Measurements VT = -229.571 +- 1.735 uVs I1Y = -45.910 +- 0.347 uTm 15:59:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:55 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = 248.099 uV, v_off_fin = 258.183 uV 16:00:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -89.644 uVs 16:00:04 Integrated Voltage Measurement... 16:00:13 Voltage Offset Correction: v_off_ini = 265.184 uV, v_off_fin = 287.024 uV 16:00:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.462 uVs 16:00:13 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = 268.835 uV, v_off_fin = 261.890 uV 16:00:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.821 uVs 16:00:22 Integrated Voltage Measurement... 16:00:31 Voltage Offset Correction: v_off_ini = 271.485 uV, v_off_fin = 285.071 uV 16:00:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.229 uVs 16:00:31 Integrated Voltage Measurement... 16:00:40 Voltage Offset Correction: v_off_ini = 271.116 uV, v_off_fin = 274.557 uV 16:00:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.649 uVs 16:00:40 Integrated Voltage Measurement... 16:00:49 Voltage Offset Correction: v_off_ini = 289.691 uV, v_off_fin = 291.467 uV 16:00:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.998 uVs 16:00:52 I2X Average and RMS of Measurements VT = -76.134 +- 3.401 uVs I2X = 7.004 +- 0.313 uTm^2 16:00:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:59 Integrated Voltage Measurement... 16:01:08 Voltage Offset Correction: v_off_ini = 276.501 uV, v_off_fin = 283.010 uV 16:01:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.024 uVs 16:01:08 Integrated Voltage Measurement... 16:01:17 Voltage Offset Correction: v_off_ini = 289.323 uV, v_off_fin = 277.146 uV 16:01:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.300 uVs 16:01:17 Integrated Voltage Measurement... 16:01:26 Voltage Offset Correction: v_off_ini = 279.269 uV, v_off_fin = 266.517 uV 16:01:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.736 uVs 16:01:27 Integrated Voltage Measurement... 16:01:35 Voltage Offset Correction: v_off_ini = 285.703 uV, v_off_fin = 275.794 uV 16:01:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.909 uVs 16:01:36 Integrated Voltage Measurement... 16:01:45 Voltage Offset Correction: v_off_ini = 281.636 uV, v_off_fin = 289.511 uV 16:01:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.697 uVs 16:01:45 Integrated Voltage Measurement... 16:01:54 Voltage Offset Correction: v_off_ini = 275.563 uV, v_off_fin = 279.316 uV 16:01:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.226 uVs 16:01:56 I2Y Average and RMS of Measurements VT = -266.649 +- 2.961 uVs I2Y = -24.532 +- 0.272 uTm^2 16:02:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:14 Integrated Voltage Measurement... 16:02:23 Voltage Offset Correction: v_off_ini = 283.548 uV, v_off_fin = 273.012 uV 16:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.407 uVs 16:02:23 Integrated Voltage Measurement... 16:02:32 Voltage Offset Correction: v_off_ini = 277.758 uV, v_off_fin = 277.159 uV 16:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.740 uVs 16:02:32 Integrated Voltage Measurement... 16:02:41 Voltage Offset Correction: v_off_ini = 275.771 uV, v_off_fin = 273.383 uV 16:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.551 uVs 16:02:41 Integrated Voltage Measurement... 16:02:50 Voltage Offset Correction: v_off_ini = 288.499 uV, v_off_fin = 289.062 uV 16:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.065 uVs 16:02:50 Integrated Voltage Measurement... 16:02:59 Voltage Offset Correction: v_off_ini = 289.809 uV, v_off_fin = 291.784 uV 16:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.684 uVs 16:02:59 Integrated Voltage Measurement... 16:03:08 Voltage Offset Correction: v_off_ini = 302.309 uV, v_off_fin = 295.528 uV 16:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.247 uVs 16:03:13 I1X Average and RMS of Measurements VT = -89.782 +- 2.758 uVs I1X = 17.956 +- 0.552 uTm 16:03:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:19 Integrated Voltage Measurement... 16:03:28 Voltage Offset Correction: v_off_ini = 300.357 uV, v_off_fin = 290.313 uV 16:03:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.108 uVs 16:03:28 Integrated Voltage Measurement... 16:03:37 Voltage Offset Correction: v_off_ini = 280.422 uV, v_off_fin = 305.776 uV 16:03:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 221.433 uVs 16:03:37 Integrated Voltage Measurement... 16:03:46 Voltage Offset Correction: v_off_ini = 299.031 uV, v_off_fin = 277.247 uV 16:03:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.025 uVs 16:03:46 Integrated Voltage Measurement... 16:03:55 Voltage Offset Correction: v_off_ini = 283.364 uV, v_off_fin = 284.584 uV 16:03:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 243.881 uVs 16:03:55 Integrated Voltage Measurement... 16:04:04 Voltage Offset Correction: v_off_ini = 283.298 uV, v_off_fin = 270.880 uV 16:04:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.224 uVs 16:04:04 Integrated Voltage Measurement... 16:04:13 Voltage Offset Correction: v_off_ini = 280.915 uV, v_off_fin = 291.489 uV 16:04:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.550 uVs 16:04:17 I1Y Average and RMS of Measurements VT = -227.537 +- 8.452 uVs I1Y = -45.503 +- 1.689 uTm 16:04:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:25 Integrated Voltage Measurement... 16:04:34 Voltage Offset Correction: v_off_ini = 294.237 uV, v_off_fin = 289.679 uV 16:04:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -85.064 uVs 16:04:34 Integrated Voltage Measurement... 16:04:43 Voltage Offset Correction: v_off_ini = 304.581 uV, v_off_fin = 294.213 uV 16:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.139 uVs 16:04:43 Integrated Voltage Measurement... 16:04:52 Voltage Offset Correction: v_off_ini = 282.610 uV, v_off_fin = 283.680 uV 16:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.704 uVs 16:04:52 Integrated Voltage Measurement... 16:05:01 Voltage Offset Correction: v_off_ini = 292.674 uV, v_off_fin = 296.401 uV 16:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.042 uVs 16:05:01 Integrated Voltage Measurement... 16:05:10 Voltage Offset Correction: v_off_ini = 274.612 uV, v_off_fin = 265.730 uV 16:05:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.641 uVs 16:05:10 Integrated Voltage Measurement... 16:05:19 Voltage Offset Correction: v_off_ini = 280.138 uV, v_off_fin = 287.230 uV 16:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.066 uVs 16:05:22 I2X Average and RMS of Measurements VT = -70.443 +- 6.435 uVs I2X = 6.480 +- 0.592 uTm^2 16:05:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:29 Integrated Voltage Measurement... 16:05:38 Voltage Offset Correction: v_off_ini = 279.782 uV, v_off_fin = 274.273 uV 16:05:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.878 uVs 16:05:38 Integrated Voltage Measurement... 16:05:47 Voltage Offset Correction: v_off_ini = 272.660 uV, v_off_fin = 271.425 uV 16:05:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.541 uVs 16:05:47 Integrated Voltage Measurement... 16:05:56 Voltage Offset Correction: v_off_ini = 290.406 uV, v_off_fin = 281.767 uV 16:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.683 uVs 16:05:56 Integrated Voltage Measurement... 16:06:05 Voltage Offset Correction: v_off_ini = 270.886 uV, v_off_fin = 273.707 uV 16:06:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.249 uVs 16:06:05 Integrated Voltage Measurement... 16:06:14 Voltage Offset Correction: v_off_ini = 271.278 uV, v_off_fin = 273.326 uV 16:06:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.938 uVs 16:06:14 Integrated Voltage Measurement... 16:06:23 Voltage Offset Correction: v_off_ini = 255.725 uV, v_off_fin = 264.056 uV 16:06:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.007 uVs 16:06:26 I2Y Average and RMS of Measurements VT = -245.549 +- 4.547 uVs I2Y = -22.591 +- 0.418 uTm^2 16:06:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:44 Integrated Voltage Measurement... 16:06:53 Voltage Offset Correction: v_off_ini = 279.393 uV, v_off_fin = 272.883 uV 16:06:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.199 uVs 16:06:53 Integrated Voltage Measurement... 16:07:02 Voltage Offset Correction: v_off_ini = 292.696 uV, v_off_fin = 290.627 uV 16:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.782 uVs 16:07:02 Integrated Voltage Measurement... 16:07:11 Voltage Offset Correction: v_off_ini = 283.567 uV, v_off_fin = 284.025 uV 16:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.604 uVs 16:07:11 Integrated Voltage Measurement... 16:07:20 Voltage Offset Correction: v_off_ini = 279.128 uV, v_off_fin = 293.660 uV 16:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.584 uVs 16:07:20 Integrated Voltage Measurement... 16:07:29 Voltage Offset Correction: v_off_ini = 283.061 uV, v_off_fin = 281.178 uV 16:07:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.794 uVs 16:07:29 Integrated Voltage Measurement... 16:07:38 Voltage Offset Correction: v_off_ini = 299.404 uV, v_off_fin = 294.163 uV 16:07:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.369 uVs 16:07:42 I1X Average and RMS of Measurements VT = -79.222 +- 3.371 uVs I1X = 15.845 +- 0.674 uTm 16:07:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:49 Integrated Voltage Measurement... 16:07:58 Voltage Offset Correction: v_off_ini = 286.731 uV, v_off_fin = 268.395 uV 16:07:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.478 uVs 16:07:58 Integrated Voltage Measurement... 16:08:07 Voltage Offset Correction: v_off_ini = 277.282 uV, v_off_fin = 294.508 uV 16:08:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.261 uVs 16:08:07 Integrated Voltage Measurement... 16:08:16 Voltage Offset Correction: v_off_ini = 284.756 uV, v_off_fin = 271.929 uV 16:08:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.025 uVs 16:08:16 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = 293.649 uV, v_off_fin = 308.835 uV 16:08:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.590 uVs 16:08:25 Integrated Voltage Measurement... 16:08:34 Voltage Offset Correction: v_off_ini = 282.249 uV, v_off_fin = 285.516 uV 16:08:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.656 uVs 16:08:34 Integrated Voltage Measurement... 16:08:43 Voltage Offset Correction: v_off_ini = 282.711 uV, v_off_fin = 306.765 uV 16:08:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.616 uVs 16:08:47 I1Y Average and RMS of Measurements VT = -214.604 +- 5.292 uVs I1Y = -42.919 +- 1.057 uTm 16:08:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:55 Integrated Voltage Measurement... 16:09:04 Voltage Offset Correction: v_off_ini = 288.087 uV, v_off_fin = 293.086 uV 16:09:04 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -86.634 uVs 16:09:04 Integrated Voltage Measurement... 16:09:13 Voltage Offset Correction: v_off_ini = 295.894 uV, v_off_fin = 311.186 uV 16:09:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.910 uVs 16:09:13 Integrated Voltage Measurement... 16:09:22 Voltage Offset Correction: v_off_ini = 310.164 uV, v_off_fin = 309.238 uV 16:09:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -75.700 uVs 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 308.682 uV, v_off_fin = 313.612 uV 16:09:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.237 uVs 16:09:31 Integrated Voltage Measurement... 16:09:40 Voltage Offset Correction: v_off_ini = 299.549 uV, v_off_fin = 308.879 uV 16:09:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.965 uVs 16:09:40 Integrated Voltage Measurement... 16:09:49 Voltage Offset Correction: v_off_ini = 310.338 uV, v_off_fin = 321.598 uV 16:09:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.474 uVs 16:09:51 I2X Average and RMS of Measurements VT = -73.153 +- 6.387 uVs I2X = 6.730 +- 0.587 uTm^2 16:09:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:59 Integrated Voltage Measurement... 16:10:08 Voltage Offset Correction: v_off_ini = 312.002 uV, v_off_fin = 314.229 uV 16:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.905 uVs 16:10:08 Integrated Voltage Measurement... 16:10:17 Voltage Offset Correction: v_off_ini = 309.966 uV, v_off_fin = 313.403 uV 16:10:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.467 uVs 16:10:17 Integrated Voltage Measurement... 16:10:26 Voltage Offset Correction: v_off_ini = 311.157 uV, v_off_fin = 312.114 uV 16:10:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.531 uVs 16:10:26 Integrated Voltage Measurement... 16:10:35 Voltage Offset Correction: v_off_ini = 323.860 uV, v_off_fin = 323.544 uV 16:10:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.524 uVs 16:10:35 Integrated Voltage Measurement... 16:10:44 Voltage Offset Correction: v_off_ini = 316.511 uV, v_off_fin = 325.481 uV 16:10:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.858 uVs 16:10:44 Integrated Voltage Measurement... 16:10:53 Voltage Offset Correction: v_off_ini = 340.691 uV, v_off_fin = 332.065 uV 16:10:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.167 uVs 16:10:56 I2Y Average and RMS of Measurements VT = -242.409 +- 3.264 uVs I2Y = -22.302 +- 0.300 uTm^2 16:10:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm