SLAC Magnetic Measurements Date: 10-14-2025 Time: 08:34:14 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16346 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 08:34:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:34:23 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:34:25 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:34:26 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:34:28 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 08:35:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 08:35:11 Integrated Voltage Measurement... 08:35:20 Voltage Offset Correction: v_off_ini = -212.293 uV, v_off_fin = -226.111 uV 08:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.933 uVs 08:35:20 Integrated Voltage Measurement... 08:35:29 Voltage Offset Correction: v_off_ini = -220.690 uV, v_off_fin = -220.199 uV 08:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 70.402 uVs 08:35:29 Integrated Voltage Measurement... 08:35:38 Voltage Offset Correction: v_off_ini = -214.645 uV, v_off_fin = -213.663 uV 08:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.466 uVs 08:35:38 Integrated Voltage Measurement... 08:35:47 Voltage Offset Correction: v_off_ini = -227.152 uV, v_off_fin = -226.795 uV 08:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.979 uVs 08:35:47 Integrated Voltage Measurement... 08:35:56 Voltage Offset Correction: v_off_ini = -235.346 uV, v_off_fin = -226.094 uV 08:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.204 uVs 08:35:56 Integrated Voltage Measurement... 08:36:05 Voltage Offset Correction: v_off_ini = -219.373 uV, v_off_fin = -221.319 uV 08:36:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.079 uVs 08:36:09 I1X Average and RMS of Measurements VT = -86.677 +- 9.280 uVs I1X = 17.336 +- 1.856 uTm 08:36:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 08:36:16 Integrated Voltage Measurement... 08:36:25 Voltage Offset Correction: v_off_ini = -222.976 uV, v_off_fin = -235.494 uV 08:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.068 uVs 08:36:25 Integrated Voltage Measurement... 08:36:34 Voltage Offset Correction: v_off_ini = -237.550 uV, v_off_fin = -210.890 uV 08:36:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.763 uVs 08:36:34 Integrated Voltage Measurement... 08:36:43 Voltage Offset Correction: v_off_ini = -213.811 uV, v_off_fin = -221.082 uV 08:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.847 uVs 08:36:43 Integrated Voltage Measurement... 08:36:52 Voltage Offset Correction: v_off_ini = -222.780 uV, v_off_fin = -205.134 uV 08:36:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.492 uVs 08:36:52 Integrated Voltage Measurement... 08:37:01 Voltage Offset Correction: v_off_ini = -215.057 uV, v_off_fin = -218.697 uV 08:37:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.274 uVs 08:37:01 Integrated Voltage Measurement... 08:37:10 Voltage Offset Correction: v_off_ini = -239.349 uV, v_off_fin = -216.951 uV 08:37:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.374 uVs 08:37:14 I1Y Average and RMS of Measurements VT = -166.303 +- 1.566 uVs I1Y = -33.261 +- 0.313 uTm 08:37:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 08:37:22 Integrated Voltage Measurement... 08:37:31 Voltage Offset Correction: v_off_ini = -216.590 uV, v_off_fin = -220.465 uV 08:37:31 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.470 uVs 08:37:31 Integrated Voltage Measurement... 08:37:40 Voltage Offset Correction: v_off_ini = -221.199 uV, v_off_fin = -199.822 uV 08:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.411 uVs 08:37:40 Integrated Voltage Measurement... 08:37:49 Voltage Offset Correction: v_off_ini = -211.041 uV, v_off_fin = -231.357 uV 08:37:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.652 uVs 08:37:49 Integrated Voltage Measurement... 08:37:58 Voltage Offset Correction: v_off_ini = -213.037 uV, v_off_fin = -198.939 uV 08:37:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.109 uVs 08:37:58 Integrated Voltage Measurement... 08:38:07 Voltage Offset Correction: v_off_ini = -214.695 uV, v_off_fin = -221.797 uV 08:38:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.273 uVs 08:38:07 Integrated Voltage Measurement... 08:38:16 Voltage Offset Correction: v_off_ini = -212.120 uV, v_off_fin = -194.303 uV 08:38:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.671 uVs 08:38:18 I2X Average and RMS of Measurements VT = -106.431 +- 10.186 uVs I2X = 9.791 +- 0.937 uTm^2 08:38:23 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 08:38:26 Integrated Voltage Measurement... 08:38:35 Voltage Offset Correction: v_off_ini = -198.205 uV, v_off_fin = -206.291 uV 08:38:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.549 uVs 08:38:35 Integrated Voltage Measurement... 08:38:44 Voltage Offset Correction: v_off_ini = -198.495 uV, v_off_fin = -212.951 uV 08:38:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.571 uVs 08:38:44 Integrated Voltage Measurement... 08:38:53 Voltage Offset Correction: v_off_ini = -198.416 uV, v_off_fin = -200.307 uV 08:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.468 uVs 08:38:53 Integrated Voltage Measurement... 08:39:02 Voltage Offset Correction: v_off_ini = -199.489 uV, v_off_fin = -190.026 uV 08:39:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.355 uVs 08:39:02 Integrated Voltage Measurement... 08:39:11 Voltage Offset Correction: v_off_ini = -196.285 uV, v_off_fin = -191.293 uV 08:39:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.171 uVs 08:39:11 Integrated Voltage Measurement... 08:39:20 Voltage Offset Correction: v_off_ini = -192.903 uV, v_off_fin = -182.163 uV 08:39:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.440 uVs 08:39:22 I2Y Average and RMS of Measurements VT = -231.926 +- 4.647 uVs I2Y = -21.337 +- 0.428 uTm^2 08:39:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 08:39:31 Integrated Voltage Measurement... 08:39:40 Voltage Offset Correction: v_off_ini = -176.675 uV, v_off_fin = -185.913 uV 08:39:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.452 uVs 08:39:40 Integrated Voltage Measurement... 08:39:49 Voltage Offset Correction: v_off_ini = -175.205 uV, v_off_fin = -166.537 uV 08:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.814 uVs 08:39:49 Integrated Voltage Measurement... 08:39:58 Voltage Offset Correction: v_off_ini = -180.119 uV, v_off_fin = -182.074 uV 08:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.633 uVs 08:39:58 Integrated Voltage Measurement... 08:40:07 Voltage Offset Correction: v_off_ini = -170.284 uV, v_off_fin = -188.715 uV 08:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.914 uVs 08:40:07 Integrated Voltage Measurement... 08:40:16 Voltage Offset Correction: v_off_ini = -183.158 uV, v_off_fin = -179.563 uV 08:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.316 uVs 08:40:16 Integrated Voltage Measurement... 08:40:25 Voltage Offset Correction: v_off_ini = -174.203 uV, v_off_fin = -178.851 uV 08:40:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.911 uVs 08:40:29 I1X Average and RMS of Measurements VT = -68.007 +- 10.268 uVs I1X = 13.601 +- 2.054 uTm 08:40:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 08:40:36 Integrated Voltage Measurement... 08:40:45 Voltage Offset Correction: v_off_ini = -167.126 uV, v_off_fin = -181.278 uV 08:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.480 uVs 08:40:45 Integrated Voltage Measurement... 08:40:54 Voltage Offset Correction: v_off_ini = -157.613 uV, v_off_fin = -157.505 uV 08:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.743 uVs 08:40:54 Integrated Voltage Measurement... 08:41:03 Voltage Offset Correction: v_off_ini = -159.810 uV, v_off_fin = -171.444 uV 08:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.321 uVs 08:41:03 Integrated Voltage Measurement... 08:41:12 Voltage Offset Correction: v_off_ini = -167.755 uV, v_off_fin = -161.199 uV 08:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.422 uVs 08:41:12 Integrated Voltage Measurement... 08:41:21 Voltage Offset Correction: v_off_ini = -155.182 uV, v_off_fin = -163.481 uV 08:41:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.621 uVs 08:41:21 Integrated Voltage Measurement... 08:41:30 Voltage Offset Correction: v_off_ini = -161.569 uV, v_off_fin = -161.511 uV 08:41:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.744 uVs 08:41:34 I1Y Average and RMS of Measurements VT = -157.888 +- 3.413 uVs I1Y = -31.578 +- 0.683 uTm 08:41:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 08:41:42 Integrated Voltage Measurement... 08:41:51 Voltage Offset Correction: v_off_ini = -172.502 uV, v_off_fin = -177.272 uV 08:41:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -87.041 uVs 08:41:51 Integrated Voltage Measurement... 08:42:00 Voltage Offset Correction: v_off_ini = -174.056 uV, v_off_fin = -165.321 uV 08:42:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.362 uVs 08:42:00 Integrated Voltage Measurement... 08:42:09 Voltage Offset Correction: v_off_ini = -178.690 uV, v_off_fin = -175.333 uV 08:42:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.605 uVs 08:42:09 Integrated Voltage Measurement... 08:42:18 Voltage Offset Correction: v_off_ini = -169.208 uV, v_off_fin = -157.795 uV 08:42:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.062 uVs 08:42:18 Integrated Voltage Measurement... 08:42:27 Voltage Offset Correction: v_off_ini = -172.714 uV, v_off_fin = -178.137 uV 08:42:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.894 uVs 08:42:27 Integrated Voltage Measurement... 08:42:36 Voltage Offset Correction: v_off_ini = -176.262 uV, v_off_fin = -173.537 uV 08:42:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.280 uVs 08:42:38 I2X Average and RMS of Measurements VT = -88.041 +- 10.422 uVs I2X = 8.100 +- 0.959 uTm^2 08:42:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 08:42:46 Integrated Voltage Measurement... 08:42:55 Voltage Offset Correction: v_off_ini = -193.997 uV, v_off_fin = -190.877 uV 08:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.629 uVs 08:42:55 Integrated Voltage Measurement... 08:43:04 Voltage Offset Correction: v_off_ini = -195.369 uV, v_off_fin = -199.222 uV 08:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.543 uVs 08:43:04 Integrated Voltage Measurement... 08:43:13 Voltage Offset Correction: v_off_ini = -206.252 uV, v_off_fin = -204.143 uV 08:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.447 uVs 08:43:13 Integrated Voltage Measurement... 08:43:22 Voltage Offset Correction: v_off_ini = -204.098 uV, v_off_fin = -203.659 uV 08:43:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.111 uVs 08:43:22 Integrated Voltage Measurement... 08:43:31 Voltage Offset Correction: v_off_ini = -212.437 uV, v_off_fin = -208.333 uV 08:43:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.573 uVs 08:43:31 Integrated Voltage Measurement... 08:43:40 Voltage Offset Correction: v_off_ini = -206.721 uV, v_off_fin = -208.553 uV 08:43:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.806 uVs 08:43:43 I2Y Average and RMS of Measurements VT = -224.185 +- 4.349 uVs I2Y = -20.625 +- 0.400 uTm^2 08:43:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:43:52 Integrated Voltage Measurement... 08:44:01 Voltage Offset Correction: v_off_ini = -203.887 uV, v_off_fin = -198.621 uV 08:44:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -40.490 uVs 08:44:01 Integrated Voltage Measurement... 08:44:10 Voltage Offset Correction: v_off_ini = -199.622 uV, v_off_fin = -193.436 uV 08:44:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.430 uVs 08:44:10 Integrated Voltage Measurement... 08:44:19 Voltage Offset Correction: v_off_ini = -203.129 uV, v_off_fin = -206.271 uV 08:44:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.761 uVs 08:44:19 Integrated Voltage Measurement... 08:44:28 Voltage Offset Correction: v_off_ini = -194.794 uV, v_off_fin = -190.795 uV 08:44:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.216 uVs 08:44:28 Integrated Voltage Measurement... 08:44:37 Voltage Offset Correction: v_off_ini = -198.903 uV, v_off_fin = -200.562 uV 08:44:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.495 uVs 08:44:37 Integrated Voltage Measurement... 08:44:46 Voltage Offset Correction: v_off_ini = -198.121 uV, v_off_fin = -194.545 uV 08:44:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.646 uVs 08:44:50 I1X Average and RMS of Measurements VT = -56.673 +- 10.064 uVs I1X = 11.335 +- 2.013 uTm 08:44:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:44:57 Integrated Voltage Measurement... 08:45:06 Voltage Offset Correction: v_off_ini = -196.263 uV, v_off_fin = -209.140 uV 08:45:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.352 uVs 08:45:06 Integrated Voltage Measurement... 08:45:15 Voltage Offset Correction: v_off_ini = -197.208 uV, v_off_fin = -184.830 uV 08:45:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 138.365 uVs 08:45:15 Integrated Voltage Measurement... 08:45:24 Voltage Offset Correction: v_off_ini = -201.308 uV, v_off_fin = -203.128 uV 08:45:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.798 uVs 08:45:24 Integrated Voltage Measurement... 08:45:33 Voltage Offset Correction: v_off_ini = -203.026 uV, v_off_fin = -183.361 uV 08:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.656 uVs 08:45:33 Integrated Voltage Measurement... 08:45:42 Voltage Offset Correction: v_off_ini = -190.180 uV, v_off_fin = -202.047 uV 08:45:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -138.705 uVs 08:45:42 Integrated Voltage Measurement... 08:45:51 Voltage Offset Correction: v_off_ini = -197.814 uV, v_off_fin = -185.005 uV 08:45:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.611 uVs 08:45:55 I1Y Average and RMS of Measurements VT = -154.248 +- 4.707 uVs I1Y = -30.850 +- 0.941 uTm 08:46:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:46:03 Integrated Voltage Measurement... 08:46:12 Voltage Offset Correction: v_off_ini = -185.044 uV, v_off_fin = -194.228 uV 08:46:12 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -84.440 uVs 08:46:12 Integrated Voltage Measurement... 08:46:21 Voltage Offset Correction: v_off_ini = -192.213 uV, v_off_fin = -174.950 uV 08:46:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.230 uVs 08:46:21 Integrated Voltage Measurement... 08:46:30 Voltage Offset Correction: v_off_ini = -175.828 uV, v_off_fin = -194.906 uV 08:46:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.162 uVs 08:46:30 Integrated Voltage Measurement... 08:46:39 Voltage Offset Correction: v_off_ini = -183.543 uV, v_off_fin = -161.614 uV 08:46:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.340 uVs 08:46:39 Integrated Voltage Measurement... 08:46:48 Voltage Offset Correction: v_off_ini = -188.763 uV, v_off_fin = -188.797 uV 08:46:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.065 uVs 08:46:48 Integrated Voltage Measurement... 08:46:57 Voltage Offset Correction: v_off_ini = -174.508 uV, v_off_fin = -159.026 uV 08:46:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.327 uVs 08:46:59 I2X Average and RMS of Measurements VT = -70.761 +- 7.837 uVs I2X = 6.510 +- 0.721 uTm^2 08:47:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:47:07 Integrated Voltage Measurement... 08:47:16 Voltage Offset Correction: v_off_ini = -168.925 uV, v_off_fin = -175.686 uV 08:47:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.898 uVs 08:47:16 Integrated Voltage Measurement... 08:47:25 Voltage Offset Correction: v_off_ini = -177.963 uV, v_off_fin = -178.937 uV 08:47:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.088 uVs 08:47:25 Integrated Voltage Measurement... 08:47:34 Voltage Offset Correction: v_off_ini = -166.362 uV, v_off_fin = -184.837 uV 08:47:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.847 uVs 08:47:34 Integrated Voltage Measurement... 08:47:43 Voltage Offset Correction: v_off_ini = -182.747 uV, v_off_fin = -160.551 uV 08:47:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.833 uVs 08:47:43 Integrated Voltage Measurement... 08:47:52 Voltage Offset Correction: v_off_ini = -173.149 uV, v_off_fin = -155.876 uV 08:47:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.562 uVs 08:47:52 Integrated Voltage Measurement... 08:48:01 Voltage Offset Correction: v_off_ini = -159.426 uV, v_off_fin = -162.171 uV 08:48:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.400 uVs 08:48:04 I2Y Average and RMS of Measurements VT = -211.605 +- 1.615 uVs I2Y = -19.468 +- 0.149 uTm^2 08:48:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 08:48:13 Integrated Voltage Measurement... 08:48:22 Voltage Offset Correction: v_off_ini = -155.232 uV, v_off_fin = -176.332 uV 08:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.610 uVs 08:48:22 Integrated Voltage Measurement... 08:48:31 Voltage Offset Correction: v_off_ini = -167.079 uV, v_off_fin = -168.343 uV 08:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.995 uVs 08:48:31 Integrated Voltage Measurement... 08:48:40 Voltage Offset Correction: v_off_ini = -197.432 uV, v_off_fin = -186.385 uV 08:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.092 uVs 08:48:40 Integrated Voltage Measurement... 08:48:49 Voltage Offset Correction: v_off_ini = -191.963 uV, v_off_fin = -192.609 uV 08:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.995 uVs 08:48:49 Integrated Voltage Measurement... 08:48:58 Voltage Offset Correction: v_off_ini = -202.564 uV, v_off_fin = -203.496 uV 08:48:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.522 uVs 08:48:58 Integrated Voltage Measurement... 08:49:07 Voltage Offset Correction: v_off_ini = -198.312 uV, v_off_fin = -188.330 uV 08:49:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.983 uVs 08:49:11 I1X Average and RMS of Measurements VT = -39.366 +- 6.171 uVs I1X = 7.873 +- 1.234 uTm 08:49:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 08:49:18 Integrated Voltage Measurement... 08:49:27 Voltage Offset Correction: v_off_ini = -195.459 uV, v_off_fin = -198.819 uV 08:49:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.967 uVs 08:49:27 Integrated Voltage Measurement... 08:49:36 Voltage Offset Correction: v_off_ini = -186.687 uV, v_off_fin = -191.358 uV 08:49:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 152.341 uVs 08:49:36 Integrated Voltage Measurement... 08:49:45 Voltage Offset Correction: v_off_ini = -193.739 uV, v_off_fin = -207.438 uV 08:49:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.443 uVs 08:49:45 Integrated Voltage Measurement... 08:49:54 Voltage Offset Correction: v_off_ini = -202.718 uV, v_off_fin = -188.519 uV 08:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.927 uVs 08:49:54 Integrated Voltage Measurement... 08:50:03 Voltage Offset Correction: v_off_ini = -200.663 uV, v_off_fin = -201.736 uV 08:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.189 uVs 08:50:03 Integrated Voltage Measurement... 08:50:12 Voltage Offset Correction: v_off_ini = -198.409 uV, v_off_fin = -191.579 uV 08:50:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.233 uVs 08:50:16 I1Y Average and RMS of Measurements VT = -150.850 +- 1.199 uVs I1Y = -30.171 +- 0.238 uTm 08:50:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 08:50:24 Integrated Voltage Measurement... 08:50:33 Voltage Offset Correction: v_off_ini = -187.410 uV, v_off_fin = -189.697 uV 08:50:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -54.710 uVs 08:50:33 Integrated Voltage Measurement... 08:50:42 Voltage Offset Correction: v_off_ini = -181.981 uV, v_off_fin = -174.981 uV 08:50:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.742 uVs 08:50:42 Integrated Voltage Measurement... 08:50:51 Voltage Offset Correction: v_off_ini = -195.130 uV, v_off_fin = -194.040 uV 08:50:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -55.934 uVs 08:50:51 Integrated Voltage Measurement... 08:51:00 Voltage Offset Correction: v_off_ini = -201.179 uV, v_off_fin = -182.933 uV 08:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.450 uVs 08:51:00 Integrated Voltage Measurement... 08:51:09 Voltage Offset Correction: v_off_ini = -207.077 uV, v_off_fin = -204.134 uV 08:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.852 uVs 08:51:09 Integrated Voltage Measurement... 08:51:18 Voltage Offset Correction: v_off_ini = -184.258 uV, v_off_fin = -173.430 uV 08:51:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.916 uVs 08:51:20 I2X Average and RMS of Measurements VT = -48.101 +- 4.861 uVs I2X = 4.425 +- 0.447 uTm^2 08:51:25 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 08:51:28 Integrated Voltage Measurement... 08:51:37 Voltage Offset Correction: v_off_ini = -194.754 uV, v_off_fin = -185.001 uV 08:51:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.321 uVs 08:51:37 Integrated Voltage Measurement... 08:51:46 Voltage Offset Correction: v_off_ini = -187.066 uV, v_off_fin = -183.399 uV 08:51:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.619 uVs 08:51:46 Integrated Voltage Measurement... 08:51:55 Voltage Offset Correction: v_off_ini = -196.843 uV, v_off_fin = -192.278 uV 08:51:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.755 uVs 08:51:55 Integrated Voltage Measurement... 08:52:04 Voltage Offset Correction: v_off_ini = -194.026 uV, v_off_fin = -190.771 uV 08:52:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.771 uVs 08:52:04 Integrated Voltage Measurement... 08:52:13 Voltage Offset Correction: v_off_ini = -195.275 uV, v_off_fin = -190.395 uV 08:52:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.017 uVs 08:52:13 Integrated Voltage Measurement... 08:52:22 Voltage Offset Correction: v_off_ini = -183.576 uV, v_off_fin = -186.612 uV 08:52:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.990 uVs 08:52:25 I2Y Average and RMS of Measurements VT = -215.412 +- 8.703 uVs I2Y = -19.818 +- 0.801 uTm^2 08:52:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 08:52:33 Integrated Voltage Measurement... 08:52:42 Voltage Offset Correction: v_off_ini = -180.130 uV, v_off_fin = -182.334 uV 08:52:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -8.694 uVs 08:52:42 Integrated Voltage Measurement... 08:52:51 Voltage Offset Correction: v_off_ini = -160.284 uV, v_off_fin = -167.094 uV 08:52:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.002 uVs 08:52:51 Integrated Voltage Measurement... 08:53:00 Voltage Offset Correction: v_off_ini = -177.024 uV, v_off_fin = -175.070 uV 08:53:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.756 uVs 08:53:00 Integrated Voltage Measurement... 08:53:09 Voltage Offset Correction: v_off_ini = -178.697 uV, v_off_fin = -173.147 uV 08:53:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.858 uVs 08:53:09 Integrated Voltage Measurement... 08:53:18 Voltage Offset Correction: v_off_ini = -177.247 uV, v_off_fin = -178.041 uV 08:53:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.596 uVs 08:53:19 Integrated Voltage Measurement... 08:53:27 Voltage Offset Correction: v_off_ini = -178.114 uV, v_off_fin = -185.013 uV 08:53:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.391 uVs 08:53:32 I1X Average and RMS of Measurements VT = -23.883 +- 8.440 uVs I1X = 4.777 +- 1.688 uTm 08:53:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 08:53:39 Integrated Voltage Measurement... 08:53:47 Voltage Offset Correction: v_off_ini = -156.285 uV, v_off_fin = -158.057 uV 08:53:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.642 uVs 08:53:48 Integrated Voltage Measurement... 08:53:56 Voltage Offset Correction: v_off_ini = -164.620 uV, v_off_fin = -157.157 uV 08:53:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.949 uVs 08:53:57 Integrated Voltage Measurement... 08:54:05 Voltage Offset Correction: v_off_ini = -174.931 uV, v_off_fin = -175.868 uV 08:54:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.113 uVs 08:54:06 Integrated Voltage Measurement... 08:54:14 Voltage Offset Correction: v_off_ini = -180.410 uV, v_off_fin = -169.271 uV 08:54:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.196 uVs 08:54:14 Integrated Voltage Measurement... 08:54:23 Voltage Offset Correction: v_off_ini = -163.813 uV, v_off_fin = -166.811 uV 08:54:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.750 uVs 08:54:23 Integrated Voltage Measurement... 08:54:32 Voltage Offset Correction: v_off_ini = -165.129 uV, v_off_fin = -160.889 uV 08:54:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 148.874 uVs 08:54:37 I1Y Average and RMS of Measurements VT = -149.254 +- 5.205 uVs I1Y = -29.851 +- 1.042 uTm 08:54:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 08:54:44 Integrated Voltage Measurement... 08:54:53 Voltage Offset Correction: v_off_ini = -156.735 uV, v_off_fin = -162.764 uV 08:54:53 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -68.491 uVs 08:54:53 Integrated Voltage Measurement... 08:55:02 Voltage Offset Correction: v_off_ini = -159.239 uV, v_off_fin = -145.554 uV 08:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.332 uVs 08:55:02 Integrated Voltage Measurement... 08:55:11 Voltage Offset Correction: v_off_ini = -148.383 uV, v_off_fin = -153.748 uV 08:55:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.474 uVs 08:55:11 Integrated Voltage Measurement... 08:55:20 Voltage Offset Correction: v_off_ini = -151.425 uV, v_off_fin = -136.675 uV 08:55:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.334 uVs 08:55:20 Integrated Voltage Measurement... 08:55:29 Voltage Offset Correction: v_off_ini = -146.703 uV, v_off_fin = -160.700 uV 08:55:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.671 uVs 08:55:29 Integrated Voltage Measurement... 08:55:38 Voltage Offset Correction: v_off_ini = -151.307 uV, v_off_fin = -142.274 uV 08:55:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.986 uVs 08:55:41 I2X Average and RMS of Measurements VT = -37.548 +- 4.906 uVs I2X = 3.454 +- 0.451 uTm^2 08:55:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 08:55:48 Integrated Voltage Measurement... 08:55:57 Voltage Offset Correction: v_off_ini = -154.288 uV, v_off_fin = -155.298 uV 08:55:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.162 uVs 08:55:58 Integrated Voltage Measurement... 08:56:06 Voltage Offset Correction: v_off_ini = -150.179 uV, v_off_fin = -141.761 uV 08:56:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.240 uVs 08:56:07 Integrated Voltage Measurement... 08:56:16 Voltage Offset Correction: v_off_ini = -147.320 uV, v_off_fin = -150.211 uV 08:56:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.236 uVs 08:56:16 Integrated Voltage Measurement... 08:56:25 Voltage Offset Correction: v_off_ini = -141.758 uV, v_off_fin = -145.760 uV 08:56:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.359 uVs 08:56:25 Integrated Voltage Measurement... 08:56:34 Voltage Offset Correction: v_off_ini = -144.542 uV, v_off_fin = -145.245 uV 08:56:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.760 uVs 08:56:34 Integrated Voltage Measurement... 08:56:43 Voltage Offset Correction: v_off_ini = -138.099 uV, v_off_fin = -144.303 uV 08:56:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.674 uVs 08:56:45 I2Y Average and RMS of Measurements VT = -201.238 +- 5.009 uVs I2Y = -18.514 +- 0.461 uTm^2 08:56:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 08:56:57 Integrated Voltage Measurement... 08:57:06 Voltage Offset Correction: v_off_ini = -134.654 uV, v_off_fin = -143.597 uV 08:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -47.425 uVs 08:57:06 Integrated Voltage Measurement... 08:57:15 Voltage Offset Correction: v_off_ini = -137.136 uV, v_off_fin = -142.453 uV 08:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.949 uVs 08:57:15 Integrated Voltage Measurement... 08:57:24 Voltage Offset Correction: v_off_ini = -139.486 uV, v_off_fin = -150.894 uV 08:57:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.561 uVs 08:57:24 Integrated Voltage Measurement... 08:57:33 Voltage Offset Correction: v_off_ini = -151.449 uV, v_off_fin = -138.126 uV 08:57:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.212 uVs 08:57:33 Integrated Voltage Measurement... 08:57:42 Voltage Offset Correction: v_off_ini = -150.551 uV, v_off_fin = -154.415 uV 08:57:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.917 uVs 08:57:42 Integrated Voltage Measurement... 08:57:51 Voltage Offset Correction: v_off_ini = -136.293 uV, v_off_fin = -130.064 uV 08:57:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.600 uVs 08:57:55 I1X Average and RMS of Measurements VT = -41.611 +- 5.473 uVs I1X = 8.322 +- 1.094 uTm 08:57:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 08:58:02 Integrated Voltage Measurement... 08:58:11 Voltage Offset Correction: v_off_ini = -131.387 uV, v_off_fin = -140.829 uV 08:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.824 uVs 08:58:11 Integrated Voltage Measurement... 08:58:20 Voltage Offset Correction: v_off_ini = -140.904 uV, v_off_fin = -131.532 uV 08:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.069 uVs 08:58:20 Integrated Voltage Measurement... 08:58:29 Voltage Offset Correction: v_off_ini = -147.409 uV, v_off_fin = -156.011 uV 08:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.328 uVs 08:58:29 Integrated Voltage Measurement... 08:58:38 Voltage Offset Correction: v_off_ini = -135.362 uV, v_off_fin = -141.362 uV 08:58:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.107 uVs 08:58:38 Integrated Voltage Measurement... 08:58:47 Voltage Offset Correction: v_off_ini = -137.118 uV, v_off_fin = -125.540 uV 08:58:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.139 uVs 08:58:47 Integrated Voltage Measurement... 08:58:56 Voltage Offset Correction: v_off_ini = -137.428 uV, v_off_fin = -110.566 uV 08:58:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.165 uVs 08:59:00 I1Y Average and RMS of Measurements VT = -165.105 +- 4.539 uVs I1Y = -33.021 +- 0.908 uTm 08:59:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 08:59:05 Integrated Voltage Measurement... 08:59:14 Voltage Offset Correction: v_off_ini = -133.069 uV, v_off_fin = -145.865 uV 08:59:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -56.068 uVs 08:59:14 Integrated Voltage Measurement... 08:59:23 Voltage Offset Correction: v_off_ini = -141.565 uV, v_off_fin = -121.009 uV 08:59:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.067 uVs 08:59:24 Integrated Voltage Measurement... 08:59:33 Voltage Offset Correction: v_off_ini = -129.372 uV, v_off_fin = -137.248 uV 08:59:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.262 uVs 08:59:33 Integrated Voltage Measurement... 08:59:42 Voltage Offset Correction: v_off_ini = -129.422 uV, v_off_fin = -114.823 uV 08:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.377 uVs 08:59:42 Integrated Voltage Measurement... 08:59:51 Voltage Offset Correction: v_off_ini = -122.758 uV, v_off_fin = -129.518 uV 08:59:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.436 uVs 08:59:51 Integrated Voltage Measurement... 09:00:00 Voltage Offset Correction: v_off_ini = -114.356 uV, v_off_fin = -104.623 uV 09:00:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.543 uVs 09:00:02 I2X Average and RMS of Measurements VT = -53.292 +- 3.406 uVs I2X = 4.903 +- 0.313 uTm^2 09:00:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:00:07 Integrated Voltage Measurement... 09:00:16 Voltage Offset Correction: v_off_ini = -119.297 uV, v_off_fin = -122.851 uV 09:00:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.515 uVs 09:00:16 Integrated Voltage Measurement... 09:00:25 Voltage Offset Correction: v_off_ini = -119.807 uV, v_off_fin = -121.992 uV 09:00:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.450 uVs 09:00:25 Integrated Voltage Measurement... 09:00:34 Voltage Offset Correction: v_off_ini = -127.022 uV, v_off_fin = -122.870 uV 09:00:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.315 uVs 09:00:34 Integrated Voltage Measurement... 09:00:43 Voltage Offset Correction: v_off_ini = -135.857 uV, v_off_fin = -119.033 uV 09:00:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.845 uVs 09:00:43 Integrated Voltage Measurement... 09:00:52 Voltage Offset Correction: v_off_ini = -111.760 uV, v_off_fin = -134.396 uV 09:00:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.740 uVs 09:00:52 Integrated Voltage Measurement... 09:01:01 Voltage Offset Correction: v_off_ini = -125.707 uV, v_off_fin = -125.670 uV 09:01:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.197 uVs 09:01:04 I2Y Average and RMS of Measurements VT = -244.344 +- 5.338 uVs I2Y = -22.480 +- 0.491 uTm^2 09:01:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:01:12 Integrated Voltage Measurement... 09:01:21 Voltage Offset Correction: v_off_ini = -127.131 uV, v_off_fin = -120.129 uV 09:01:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.516 uVs 09:01:21 Integrated Voltage Measurement... 09:01:30 Voltage Offset Correction: v_off_ini = -117.033 uV, v_off_fin = -112.509 uV 09:01:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.795 uVs 09:01:30 Integrated Voltage Measurement... 09:01:39 Voltage Offset Correction: v_off_ini = -121.880 uV, v_off_fin = -118.509 uV 09:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.060 uVs 09:01:39 Integrated Voltage Measurement... 09:01:48 Voltage Offset Correction: v_off_ini = -106.866 uV, v_off_fin = -105.322 uV 09:01:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 14.427 uVs 09:01:48 Integrated Voltage Measurement... 09:01:57 Voltage Offset Correction: v_off_ini = -109.153 uV, v_off_fin = -116.380 uV 09:01:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.812 uVs 09:01:57 Integrated Voltage Measurement... 09:02:06 Voltage Offset Correction: v_off_ini = -105.231 uV, v_off_fin = -96.895 uV 09:02:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.492 uVs 09:02:10 I1X Average and RMS of Measurements VT = -41.850 +- 10.998 uVs I1X = 8.370 +- 2.200 uTm 09:02:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:02:17 Integrated Voltage Measurement... 09:02:26 Voltage Offset Correction: v_off_ini = -117.236 uV, v_off_fin = -134.878 uV 09:02:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.079 uVs 09:02:26 Integrated Voltage Measurement... 09:02:35 Voltage Offset Correction: v_off_ini = -127.918 uV, v_off_fin = -109.882 uV 09:02:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.587 uVs 09:02:35 Integrated Voltage Measurement... 09:02:44 Voltage Offset Correction: v_off_ini = -127.522 uV, v_off_fin = -119.318 uV 09:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.432 uVs 09:02:44 Integrated Voltage Measurement... 09:02:53 Voltage Offset Correction: v_off_ini = -126.364 uV, v_off_fin = -119.167 uV 09:02:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.343 uVs 09:02:53 Integrated Voltage Measurement... 09:03:02 Voltage Offset Correction: v_off_ini = -127.043 uV, v_off_fin = -134.774 uV 09:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -138.300 uVs 09:03:02 Integrated Voltage Measurement... 09:03:11 Voltage Offset Correction: v_off_ini = -121.402 uV, v_off_fin = -112.881 uV 09:03:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.361 uVs 09:03:15 I1Y Average and RMS of Measurements VT = -151.850 +- 3.550 uVs I1Y = -30.370 +- 0.710 uTm 09:03:18 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:03:21 Integrated Voltage Measurement... 09:03:30 Voltage Offset Correction: v_off_ini = -114.361 uV, v_off_fin = -128.431 uV 09:03:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -76.355 uVs 09:03:30 Integrated Voltage Measurement... 09:03:39 Voltage Offset Correction: v_off_ini = -122.396 uV, v_off_fin = -121.289 uV 09:03:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.972 uVs 09:03:39 Integrated Voltage Measurement... 09:03:48 Voltage Offset Correction: v_off_ini = -125.916 uV, v_off_fin = -138.270 uV 09:03:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.508 uVs 09:03:48 Integrated Voltage Measurement... 09:03:57 Voltage Offset Correction: v_off_ini = -131.604 uV, v_off_fin = -110.777 uV 09:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.283 uVs 09:03:57 Integrated Voltage Measurement... 09:04:06 Voltage Offset Correction: v_off_ini = -126.368 uV, v_off_fin = -116.024 uV 09:04:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.358 uVs 09:04:06 Integrated Voltage Measurement... 09:04:15 Voltage Offset Correction: v_off_ini = -107.233 uV, v_off_fin = -106.210 uV 09:04:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.958 uVs 09:04:18 I2X Average and RMS of Measurements VT = -62.072 +- 7.788 uVs I2X = 5.711 +- 0.716 uTm^2 09:04:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:04:23 Integrated Voltage Measurement... 09:04:32 Voltage Offset Correction: v_off_ini = -113.281 uV, v_off_fin = -108.480 uV 09:04:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.451 uVs 09:04:32 Integrated Voltage Measurement... 09:04:41 Voltage Offset Correction: v_off_ini = -106.880 uV, v_off_fin = -115.059 uV 09:04:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.763 uVs 09:04:41 Integrated Voltage Measurement... 09:04:50 Voltage Offset Correction: v_off_ini = -118.025 uV, v_off_fin = -137.128 uV 09:04:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.397 uVs 09:04:50 Integrated Voltage Measurement... 09:04:59 Voltage Offset Correction: v_off_ini = -122.301 uV, v_off_fin = -110.553 uV 09:04:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.449 uVs 09:04:59 Integrated Voltage Measurement... 09:05:08 Voltage Offset Correction: v_off_ini = -110.663 uV, v_off_fin = -120.375 uV 09:05:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.293 uVs 09:05:08 Integrated Voltage Measurement... 09:05:17 Voltage Offset Correction: v_off_ini = -115.337 uV, v_off_fin = -112.052 uV 09:05:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.436 uVs 09:05:20 I2Y Average and RMS of Measurements VT = -224.465 +- 9.580 uVs I2Y = -20.651 +- 0.881 uTm^2 09:05:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:05:28 Integrated Voltage Measurement... 09:05:37 Voltage Offset Correction: v_off_ini = -74.794 uV, v_off_fin = -97.996 uV 09:05:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -56.149 uVs 09:05:37 Integrated Voltage Measurement... 09:05:46 Voltage Offset Correction: v_off_ini = -103.123 uV, v_off_fin = -102.771 uV 09:05:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 51.654 uVs 09:05:46 Integrated Voltage Measurement... 09:05:55 Voltage Offset Correction: v_off_ini = -108.357 uV, v_off_fin = -112.635 uV 09:05:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.685 uVs 09:05:55 Integrated Voltage Measurement... 09:06:04 Voltage Offset Correction: v_off_ini = -103.469 uV, v_off_fin = -116.173 uV 09:06:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.260 uVs 09:06:04 Integrated Voltage Measurement... 09:06:13 Voltage Offset Correction: v_off_ini = -105.785 uV, v_off_fin = -117.734 uV 09:06:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.483 uVs 09:06:13 Integrated Voltage Measurement... 09:06:22 Voltage Offset Correction: v_off_ini = -118.820 uV, v_off_fin = -112.656 uV 09:06:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.116 uVs 09:06:26 I1X Average and RMS of Measurements VT = -52.225 +- 4.184 uVs I1X = 10.446 +- 0.837 uTm 09:06:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:06:33 Integrated Voltage Measurement... 09:06:42 Voltage Offset Correction: v_off_ini = -119.425 uV, v_off_fin = -127.376 uV 09:06:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.818 uVs 09:06:42 Integrated Voltage Measurement... 09:06:51 Voltage Offset Correction: v_off_ini = -127.334 uV, v_off_fin = -124.506 uV 09:06:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 147.616 uVs 09:06:51 Integrated Voltage Measurement... 09:07:00 Voltage Offset Correction: v_off_ini = -136.737 uV, v_off_fin = -134.312 uV 09:07:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.092 uVs 09:07:00 Integrated Voltage Measurement... 09:07:09 Voltage Offset Correction: v_off_ini = -138.275 uV, v_off_fin = -116.080 uV 09:07:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.621 uVs 09:07:09 Integrated Voltage Measurement... 09:07:18 Voltage Offset Correction: v_off_ini = -119.038 uV, v_off_fin = -118.960 uV 09:07:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.662 uVs 09:07:18 Integrated Voltage Measurement... 09:07:27 Voltage Offset Correction: v_off_ini = -117.531 uV, v_off_fin = -118.443 uV 09:07:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.513 uVs 09:07:31 I1Y Average and RMS of Measurements VT = -147.887 +- 0.955 uVs I1Y = -29.577 +- 0.191 uTm 09:07:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:07:36 Integrated Voltage Measurement... 09:07:45 Voltage Offset Correction: v_off_ini = -136.329 uV, v_off_fin = -135.626 uV 09:07:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -69.979 uVs 09:07:45 Integrated Voltage Measurement... 09:07:54 Voltage Offset Correction: v_off_ini = -123.549 uV, v_off_fin = -105.828 uV 09:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.269 uVs 09:07:54 Integrated Voltage Measurement... 09:08:03 Voltage Offset Correction: v_off_ini = -124.122 uV, v_off_fin = -122.760 uV 09:08:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.168 uVs 09:08:03 Integrated Voltage Measurement... 09:08:12 Voltage Offset Correction: v_off_ini = -105.241 uV, v_off_fin = -103.595 uV 09:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.696 uVs 09:08:12 Integrated Voltage Measurement... 09:08:21 Voltage Offset Correction: v_off_ini = -108.997 uV, v_off_fin = -115.121 uV 09:08:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.492 uVs 09:08:21 Integrated Voltage Measurement... 09:08:30 Voltage Offset Correction: v_off_ini = -114.744 uV, v_off_fin = -108.195 uV 09:08:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.270 uVs 09:08:33 I2X Average and RMS of Measurements VT = -71.146 +- 6.348 uVs I2X = 6.545 +- 0.584 uTm^2 09:08:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:08:38 Integrated Voltage Measurement... 09:08:47 Voltage Offset Correction: v_off_ini = -113.696 uV, v_off_fin = -103.943 uV 09:08:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.333 uVs 09:08:47 Integrated Voltage Measurement... 09:08:56 Voltage Offset Correction: v_off_ini = -112.094 uV, v_off_fin = -109.418 uV 09:08:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.738 uVs 09:08:56 Integrated Voltage Measurement... 09:09:05 Voltage Offset Correction: v_off_ini = -108.810 uV, v_off_fin = -124.497 uV 09:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.052 uVs 09:09:05 Integrated Voltage Measurement... 09:09:14 Voltage Offset Correction: v_off_ini = -107.839 uV, v_off_fin = -119.160 uV 09:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.168 uVs 09:09:14 Integrated Voltage Measurement... 09:09:23 Voltage Offset Correction: v_off_ini = -112.146 uV, v_off_fin = -119.431 uV 09:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.554 uVs 09:09:23 Integrated Voltage Measurement... 09:09:32 Voltage Offset Correction: v_off_ini = -115.131 uV, v_off_fin = -131.696 uV 09:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.073 uVs 09:09:35 I2Y Average and RMS of Measurements VT = -224.153 +- 3.214 uVs I2Y = -20.622 +- 0.296 uTm^2 09:09:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:09:43 Integrated Voltage Measurement... 09:09:52 Voltage Offset Correction: v_off_ini = -126.004 uV, v_off_fin = -130.240 uV 09:09:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.322 uVs 09:09:52 Integrated Voltage Measurement... 09:10:01 Voltage Offset Correction: v_off_ini = -107.709 uV, v_off_fin = -114.097 uV 09:10:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 39.081 uVs 09:10:01 Integrated Voltage Measurement... 09:10:10 Voltage Offset Correction: v_off_ini = -114.853 uV, v_off_fin = -126.352 uV 09:10:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -49.433 uVs 09:10:10 Integrated Voltage Measurement... 09:10:19 Voltage Offset Correction: v_off_ini = -113.451 uV, v_off_fin = -105.998 uV 09:10:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 39.938 uVs 09:10:19 Integrated Voltage Measurement... 09:10:28 Voltage Offset Correction: v_off_ini = -111.658 uV, v_off_fin = -118.363 uV 09:10:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.784 uVs 09:10:28 Integrated Voltage Measurement... 09:10:37 Voltage Offset Correction: v_off_ini = -111.035 uV, v_off_fin = -113.596 uV 09:10:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.422 uVs 09:10:41 I1X Average and RMS of Measurements VT = -45.163 +- 3.040 uVs I1X = 9.033 +- 0.608 uTm 09:10:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:10:48 Integrated Voltage Measurement... 09:10:57 Voltage Offset Correction: v_off_ini = -121.653 uV, v_off_fin = -122.971 uV 09:10:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.065 uVs 09:10:57 Integrated Voltage Measurement... 09:11:06 Voltage Offset Correction: v_off_ini = -110.009 uV, v_off_fin = -103.953 uV 09:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.684 uVs 09:11:06 Integrated Voltage Measurement... 09:11:15 Voltage Offset Correction: v_off_ini = -110.856 uV, v_off_fin = -118.019 uV 09:11:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -133.509 uVs 09:11:15 Integrated Voltage Measurement... 09:11:24 Voltage Offset Correction: v_off_ini = -109.589 uV, v_off_fin = -100.324 uV 09:11:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 143.239 uVs 09:11:24 Integrated Voltage Measurement... 09:11:33 Voltage Offset Correction: v_off_ini = -104.956 uV, v_off_fin = -103.085 uV 09:11:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -143.304 uVs 09:11:33 Integrated Voltage Measurement... 09:11:42 Voltage Offset Correction: v_off_ini = -86.318 uV, v_off_fin = -70.546 uV 09:11:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 125.175 uVs 09:11:46 I1Y Average and RMS of Measurements VT = -136.496 +- 1.709 uVs I1Y = -27.300 +- 0.341 uTm 09:11:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:11:51 Integrated Voltage Measurement... 09:12:00 Voltage Offset Correction: v_off_ini = -102.451 uV, v_off_fin = -105.651 uV 09:12:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -59.849 uVs 09:12:00 Integrated Voltage Measurement... 09:12:09 Voltage Offset Correction: v_off_ini = -104.531 uV, v_off_fin = -96.693 uV 09:12:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.193 uVs 09:12:09 Integrated Voltage Measurement... 09:12:18 Voltage Offset Correction: v_off_ini = -96.875 uV, v_off_fin = -106.898 uV 09:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.665 uVs 09:12:18 Integrated Voltage Measurement... 09:12:27 Voltage Offset Correction: v_off_ini = -100.712 uV, v_off_fin = -101.743 uV 09:12:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.994 uVs 09:12:27 Integrated Voltage Measurement... 09:12:36 Voltage Offset Correction: v_off_ini = -99.174 uV, v_off_fin = -101.129 uV 09:12:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.052 uVs 09:12:36 Integrated Voltage Measurement... 09:12:45 Voltage Offset Correction: v_off_ini = -85.868 uV, v_off_fin = -78.439 uV 09:12:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.753 uVs 09:12:48 I2X Average and RMS of Measurements VT = -74.084 +- 2.315 uVs I2X = 6.816 +- 0.213 uTm^2 09:12:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:12:53 Integrated Voltage Measurement... 09:13:02 Voltage Offset Correction: v_off_ini = -95.488 uV, v_off_fin = -95.682 uV 09:13:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.505 uVs 09:13:02 Integrated Voltage Measurement... 09:13:11 Voltage Offset Correction: v_off_ini = -93.113 uV, v_off_fin = -88.936 uV 09:13:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.369 uVs 09:13:11 Integrated Voltage Measurement... 09:13:20 Voltage Offset Correction: v_off_ini = -91.276 uV, v_off_fin = -86.389 uV 09:13:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.194 uVs 09:13:20 Integrated Voltage Measurement... 09:13:29 Voltage Offset Correction: v_off_ini = -88.954 uV, v_off_fin = -91.103 uV 09:13:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.738 uVs 09:13:29 Integrated Voltage Measurement... 09:13:38 Voltage Offset Correction: v_off_ini = -94.083 uV, v_off_fin = -95.098 uV 09:13:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.424 uVs 09:13:38 Integrated Voltage Measurement... 09:13:47 Voltage Offset Correction: v_off_ini = -90.767 uV, v_off_fin = -93.871 uV 09:13:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.662 uVs 09:13:50 I2Y Average and RMS of Measurements VT = -204.482 +- 4.752 uVs I2Y = -18.812 +- 0.437 uTm^2 09:13:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:13:58 Integrated Voltage Measurement... 09:14:07 Voltage Offset Correction: v_off_ini = -59.663 uV, v_off_fin = -75.522 uV 09:14:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.065 uVs 09:14:07 Integrated Voltage Measurement... 09:14:16 Voltage Offset Correction: v_off_ini = -71.677 uV, v_off_fin = -60.372 uV 09:14:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.812 uVs 09:14:16 Integrated Voltage Measurement... 09:14:25 Voltage Offset Correction: v_off_ini = -81.612 uV, v_off_fin = -65.370 uV 09:14:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.918 uVs 09:14:25 Integrated Voltage Measurement... 09:14:34 Voltage Offset Correction: v_off_ini = -84.235 uV, v_off_fin = -60.166 uV 09:14:34 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 35.220 uVs 09:14:34 Integrated Voltage Measurement... 09:14:43 Voltage Offset Correction: v_off_ini = -52.388 uV, v_off_fin = -57.293 uV 09:14:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -51.627 uVs 09:14:43 Integrated Voltage Measurement... 09:14:52 Voltage Offset Correction: v_off_ini = -38.361 uV, v_off_fin = -52.709 uV 09:14:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.417 uVs 09:14:56 I1X Average and RMS of Measurements VT = -41.176 +- 3.745 uVs I1X = 8.236 +- 0.749 uTm 09:14:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:15:03 Integrated Voltage Measurement... 09:15:12 Voltage Offset Correction: v_off_ini = -72.927 uV, v_off_fin = -70.916 uV 09:15:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -115.481 uVs 09:15:12 Integrated Voltage Measurement... 09:15:21 Voltage Offset Correction: v_off_ini = -51.940 uV, v_off_fin = -44.361 uV 09:15:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 107.989 uVs 09:15:21 Integrated Voltage Measurement... 09:15:30 Voltage Offset Correction: v_off_ini = -46.911 uV, v_off_fin = -57.489 uV 09:15:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -146.426 uVs 09:15:30 Integrated Voltage Measurement... 09:15:39 Voltage Offset Correction: v_off_ini = -45.303 uV, v_off_fin = -30.945 uV 09:15:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 124.426 uVs 09:15:39 Integrated Voltage Measurement... 09:15:48 Voltage Offset Correction: v_off_ini = -48.767 uV, v_off_fin = -51.070 uV 09:15:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -119.239 uVs 09:15:48 Integrated Voltage Measurement... 09:15:57 Voltage Offset Correction: v_off_ini = -45.237 uV, v_off_fin = -23.646 uV 09:15:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 129.497 uVs 09:16:01 I1Y Average and RMS of Measurements VT = -123.843 +- 9.679 uVs I1Y = -24.768 +- 1.934 uTm 09:16:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:16:06 Integrated Voltage Measurement... 09:16:15 Voltage Offset Correction: v_off_ini = -46.720 uV, v_off_fin = -50.997 uV 09:16:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.736 uVs 09:16:15 Integrated Voltage Measurement... 09:16:24 Voltage Offset Correction: v_off_ini = -38.225 uV, v_off_fin = -38.979 uV 09:16:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.437 uVs 09:16:24 Integrated Voltage Measurement... 09:16:33 Voltage Offset Correction: v_off_ini = -52.450 uV, v_off_fin = -47.213 uV 09:16:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.673 uVs 09:16:33 Integrated Voltage Measurement... 09:16:42 Voltage Offset Correction: v_off_ini = -29.348 uV, v_off_fin = -39.510 uV 09:16:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.838 uVs 09:16:42 Integrated Voltage Measurement... 09:16:51 Voltage Offset Correction: v_off_ini = -33.978 uV, v_off_fin = -55.399 uV 09:16:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.618 uVs 09:16:51 Integrated Voltage Measurement... 09:17:00 Voltage Offset Correction: v_off_ini = -47.330 uV, v_off_fin = -38.569 uV 09:17:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.990 uVs 09:17:03 I2X Average and RMS of Measurements VT = -70.549 +- 3.556 uVs I2X = 6.491 +- 0.327 uTm^2 09:17:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:17:08 Integrated Voltage Measurement... 09:17:17 Voltage Offset Correction: v_off_ini = -37.971 uV, v_off_fin = -69.499 uV 09:17:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.335 uVs 09:17:17 Integrated Voltage Measurement... 09:17:26 Voltage Offset Correction: v_off_ini = -78.320 uV, v_off_fin = -67.910 uV 09:17:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.786 uVs 09:17:26 Integrated Voltage Measurement... 09:17:35 Voltage Offset Correction: v_off_ini = -49.244 uV, v_off_fin = -51.493 uV 09:17:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.438 uVs 09:17:35 Integrated Voltage Measurement... 09:17:44 Voltage Offset Correction: v_off_ini = -45.213 uV, v_off_fin = -40.076 uV 09:17:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.354 uVs 09:17:44 Integrated Voltage Measurement... 09:17:53 Voltage Offset Correction: v_off_ini = -41.284 uV, v_off_fin = -36.806 uV 09:17:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.284 uVs 09:17:53 Integrated Voltage Measurement... 09:18:02 Voltage Offset Correction: v_off_ini = -31.828 uV, v_off_fin = -40.919 uV 09:18:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.128 uVs 09:18:05 I2Y Average and RMS of Measurements VT = -204.221 +- 5.473 uVs I2Y = -18.788 +- 0.504 uTm^2 09:18:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:18:25 Integrated Voltage Measurement... 09:18:34 Voltage Offset Correction: v_off_ini = -21.447 uV, v_off_fin = -29.976 uV 09:18:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -90.641 uVs 09:18:34 Integrated Voltage Measurement... 09:18:43 Voltage Offset Correction: v_off_ini = -26.130 uV, v_off_fin = -16.017 uV 09:18:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.948 uVs 09:18:43 Integrated Voltage Measurement... 09:18:52 Voltage Offset Correction: v_off_ini = -16.842 uV, v_off_fin = -25.032 uV 09:18:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.509 uVs 09:18:52 Integrated Voltage Measurement... 09:19:01 Voltage Offset Correction: v_off_ini = -19.273 uV, v_off_fin = -29.240 uV 09:19:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.877 uVs 09:19:01 Integrated Voltage Measurement... 09:19:10 Voltage Offset Correction: v_off_ini = -40.173 uV, v_off_fin = -40.161 uV 09:19:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.383 uVs 09:19:10 Integrated Voltage Measurement... 09:19:19 Voltage Offset Correction: v_off_ini = -35.079 uV, v_off_fin = -23.475 uV 09:19:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.115 uVs 09:19:23 I1X Average and RMS of Measurements VT = -81.412 +- 4.336 uVs I1X = 16.283 +- 0.867 uTm 09:19:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:19:30 Integrated Voltage Measurement... 09:19:39 Voltage Offset Correction: v_off_ini = -29.502 uV, v_off_fin = -29.069 uV 09:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.332 uVs 09:19:39 Integrated Voltage Measurement... 09:19:48 Voltage Offset Correction: v_off_ini = -8.183 uV, v_off_fin = -5.824 uV 09:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.487 uVs 09:19:48 Integrated Voltage Measurement... 09:19:57 Voltage Offset Correction: v_off_ini = -36.852 uV, v_off_fin = -28.920 uV 09:19:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.556 uVs 09:19:57 Integrated Voltage Measurement... 09:20:06 Voltage Offset Correction: v_off_ini = -37.167 uV, v_off_fin = -23.119 uV 09:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.214 uVs 09:20:06 Integrated Voltage Measurement... 09:20:15 Voltage Offset Correction: v_off_ini = -25.189 uV, v_off_fin = -49.389 uV 09:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.447 uVs 09:20:15 Integrated Voltage Measurement... 09:20:24 Voltage Offset Correction: v_off_ini = -28.432 uV, v_off_fin = -14.157 uV 09:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.215 uVs 09:20:28 I1Y Average and RMS of Measurements VT = -183.875 +- 2.582 uVs I1Y = -36.775 +- 0.516 uTm 09:20:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:20:36 Integrated Voltage Measurement... 09:20:45 Voltage Offset Correction: v_off_ini = -36.991 uV, v_off_fin = -29.391 uV 09:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.403 uVs 09:20:45 Integrated Voltage Measurement... 09:20:54 Voltage Offset Correction: v_off_ini = -18.884 uV, v_off_fin = 0.235 uV 09:20:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.058 uVs 09:20:54 Integrated Voltage Measurement... 09:21:03 Voltage Offset Correction: v_off_ini = -16.323 uV, v_off_fin = -16.436 uV 09:21:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.426 uVs 09:21:03 Integrated Voltage Measurement... 09:21:12 Voltage Offset Correction: v_off_ini = -2.333 uV, v_off_fin = 16.412 uV 09:21:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.178 uVs 09:21:12 Integrated Voltage Measurement... 09:21:21 Voltage Offset Correction: v_off_ini = 0.309 uV, v_off_fin = -7.302 uV 09:21:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.761 uVs 09:21:21 Integrated Voltage Measurement... 09:21:30 Voltage Offset Correction: v_off_ini = -6.877 uV, v_off_fin = -0.541 uV 09:21:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.763 uVs 09:21:32 I2X Average and RMS of Measurements VT = -104.098 +- 4.342 uVs I2X = 9.577 +- 0.399 uTm^2 09:21:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:21:40 Integrated Voltage Measurement... 09:21:49 Voltage Offset Correction: v_off_ini = -24.953 uV, v_off_fin = -18.916 uV 09:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.246 uVs 09:21:49 Integrated Voltage Measurement... 09:21:58 Voltage Offset Correction: v_off_ini = -21.907 uV, v_off_fin = -29.033 uV 09:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.454 uVs 09:21:58 Integrated Voltage Measurement... 09:22:07 Voltage Offset Correction: v_off_ini = -20.988 uV, v_off_fin = -18.640 uV 09:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.200 uVs 09:22:07 Integrated Voltage Measurement... 09:22:16 Voltage Offset Correction: v_off_ini = -27.654 uV, v_off_fin = -37.231 uV 09:22:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.630 uVs 09:22:16 Integrated Voltage Measurement... 09:22:25 Voltage Offset Correction: v_off_ini = -42.207 uV, v_off_fin = -39.915 uV 09:22:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.181 uVs 09:22:25 Integrated Voltage Measurement... 09:22:34 Voltage Offset Correction: v_off_ini = -29.350 uV, v_off_fin = -29.534 uV 09:22:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.619 uVs 09:22:37 I2Y Average and RMS of Measurements VT = -254.388 +- 3.513 uVs I2Y = -23.404 +- 0.323 uTm^2 09:22:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:22:46 Integrated Voltage Measurement... 09:22:55 Voltage Offset Correction: v_off_ini = -19.157 uV, v_off_fin = -32.685 uV 09:22:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.705 uVs 09:22:55 Integrated Voltage Measurement... 09:23:04 Voltage Offset Correction: v_off_ini = -39.285 uV, v_off_fin = -13.411 uV 09:23:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.795 uVs 09:23:04 Integrated Voltage Measurement... 09:23:13 Voltage Offset Correction: v_off_ini = -17.663 uV, v_off_fin = -29.084 uV 09:23:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.192 uVs 09:23:13 Integrated Voltage Measurement... 09:23:22 Voltage Offset Correction: v_off_ini = -7.769 uV, v_off_fin = -26.636 uV 09:23:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.543 uVs 09:23:22 Integrated Voltage Measurement... 09:23:31 Voltage Offset Correction: v_off_ini = -30.492 uV, v_off_fin = -29.983 uV 09:23:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.005 uVs 09:23:31 Integrated Voltage Measurement... 09:23:40 Voltage Offset Correction: v_off_ini = -24.859 uV, v_off_fin = -22.155 uV 09:23:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.775 uVs 09:23:44 I1X Average and RMS of Measurements VT = -60.336 +- 3.875 uVs I1X = 12.067 +- 0.775 uTm 09:23:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:23:51 Integrated Voltage Measurement... 09:24:00 Voltage Offset Correction: v_off_ini = -38.280 uV, v_off_fin = -48.021 uV 09:24:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.647 uVs 09:24:00 Integrated Voltage Measurement... 09:24:09 Voltage Offset Correction: v_off_ini = -39.168 uV, v_off_fin = -18.610 uV 09:24:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.612 uVs 09:24:09 Integrated Voltage Measurement... 09:24:18 Voltage Offset Correction: v_off_ini = -31.170 uV, v_off_fin = -36.649 uV 09:24:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.072 uVs 09:24:18 Integrated Voltage Measurement... 09:24:27 Voltage Offset Correction: v_off_ini = -27.900 uV, v_off_fin = -24.763 uV 09:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.502 uVs 09:24:27 Integrated Voltage Measurement... 09:24:36 Voltage Offset Correction: v_off_ini = -34.587 uV, v_off_fin = -40.531 uV 09:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.607 uVs 09:24:36 Integrated Voltage Measurement... 09:24:45 Voltage Offset Correction: v_off_ini = -28.332 uV, v_off_fin = -21.094 uV 09:24:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.698 uVs 09:24:49 I1Y Average and RMS of Measurements VT = -171.190 +- 3.387 uVs I1Y = -34.238 +- 0.677 uTm 09:24:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:24:57 Integrated Voltage Measurement... 09:25:05 Voltage Offset Correction: v_off_ini = -21.571 uV, v_off_fin = -33.550 uV 09:25:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -109.946 uVs 09:25:06 Integrated Voltage Measurement... 09:25:15 Voltage Offset Correction: v_off_ini = -20.736 uV, v_off_fin = -8.162 uV 09:25:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.199 uVs 09:25:15 Integrated Voltage Measurement... 09:25:24 Voltage Offset Correction: v_off_ini = -17.313 uV, v_off_fin = -24.115 uV 09:25:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.323 uVs 09:25:24 Integrated Voltage Measurement... 09:25:33 Voltage Offset Correction: v_off_ini = -24.088 uV, v_off_fin = -13.797 uV 09:25:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.512 uVs 09:25:33 Integrated Voltage Measurement... 09:25:42 Voltage Offset Correction: v_off_ini = -24.443 uV, v_off_fin = -31.991 uV 09:25:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.613 uVs 09:25:42 Integrated Voltage Measurement... 09:25:51 Voltage Offset Correction: v_off_ini = -30.433 uV, v_off_fin = -19.611 uV 09:25:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.288 uVs 09:25:53 I2X Average and RMS of Measurements VT = -91.814 +- 10.251 uVs I2X = 8.447 +- 0.943 uTm^2 09:25:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:26:01 Integrated Voltage Measurement... 09:26:10 Voltage Offset Correction: v_off_ini = -22.714 uV, v_off_fin = -9.823 uV 09:26:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.889 uVs 09:26:10 Integrated Voltage Measurement... 09:26:19 Voltage Offset Correction: v_off_ini = -14.087 uV, v_off_fin = 1.842 uV 09:26:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.399 uVs 09:26:19 Integrated Voltage Measurement... 09:26:28 Voltage Offset Correction: v_off_ini = -1.405 uV, v_off_fin = -3.414 uV 09:26:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.439 uVs 09:26:28 Integrated Voltage Measurement... 09:26:37 Voltage Offset Correction: v_off_ini = -12.446 uV, v_off_fin = -14.828 uV 09:26:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.030 uVs 09:26:37 Integrated Voltage Measurement... 09:26:46 Voltage Offset Correction: v_off_ini = -14.424 uV, v_off_fin = -14.633 uV 09:26:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.776 uVs 09:26:46 Integrated Voltage Measurement... 09:26:55 Voltage Offset Correction: v_off_ini = -24.220 uV, v_off_fin = -10.095 uV 09:26:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.400 uVs 09:26:57 I2Y Average and RMS of Measurements VT = -252.989 +- 3.898 uVs I2Y = -23.275 +- 0.359 uTm^2 09:27:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:27:06 Integrated Voltage Measurement... 09:27:15 Voltage Offset Correction: v_off_ini = -13.891 uV, v_off_fin = -10.622 uV 09:27:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.483 uVs 09:27:15 Integrated Voltage Measurement... 09:27:24 Voltage Offset Correction: v_off_ini = -2.304 uV, v_off_fin = -15.817 uV 09:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.033 uVs 09:27:24 Integrated Voltage Measurement... 09:27:33 Voltage Offset Correction: v_off_ini = -9.255 uV, v_off_fin = -23.930 uV 09:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.306 uVs 09:27:33 Integrated Voltage Measurement... 09:27:42 Voltage Offset Correction: v_off_ini = -15.375 uV, v_off_fin = -5.445 uV 09:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.949 uVs 09:27:42 Integrated Voltage Measurement... 09:27:51 Voltage Offset Correction: v_off_ini = -0.679 uV, v_off_fin = -13.374 uV 09:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.050 uVs 09:27:51 Integrated Voltage Measurement... 09:28:00 Voltage Offset Correction: v_off_ini = -3.022 uV, v_off_fin = -4.357 uV 09:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.757 uVs 09:28:05 I1X Average and RMS of Measurements VT = -58.096 +- 0.961 uVs I1X = 11.619 +- 0.192 uTm 09:28:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:28:11 Integrated Voltage Measurement... 09:28:20 Voltage Offset Correction: v_off_ini = -1.426 uV, v_off_fin = -5.718 uV 09:28:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.815 uVs 09:28:20 Integrated Voltage Measurement... 09:28:29 Voltage Offset Correction: v_off_ini = 3.447 uV, v_off_fin = 13.431 uV 09:28:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.061 uVs 09:28:29 Integrated Voltage Measurement... 09:28:38 Voltage Offset Correction: v_off_ini = 7.116 uV, v_off_fin = 5.968 uV 09:28:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.087 uVs 09:28:38 Integrated Voltage Measurement... 09:28:47 Voltage Offset Correction: v_off_ini = 27.066 uV, v_off_fin = 28.864 uV 09:28:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.390 uVs 09:28:47 Integrated Voltage Measurement... 09:28:56 Voltage Offset Correction: v_off_ini = 6.820 uV, v_off_fin = 7.352 uV 09:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.677 uVs 09:28:56 Integrated Voltage Measurement... 09:29:05 Voltage Offset Correction: v_off_ini = 16.264 uV, v_off_fin = 30.715 uV 09:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.044 uVs 09:29:10 I1Y Average and RMS of Measurements VT = -166.512 +- 6.313 uVs I1Y = -33.302 +- 1.263 uTm 09:29:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:29:17 Integrated Voltage Measurement... 09:29:26 Voltage Offset Correction: v_off_ini = 29.358 uV, v_off_fin = 8.949 uV 09:29:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.216 uVs 09:29:26 Integrated Voltage Measurement... 09:29:35 Voltage Offset Correction: v_off_ini = 8.818 uV, v_off_fin = 24.570 uV 09:29:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.103 uVs 09:29:35 Integrated Voltage Measurement... 09:29:44 Voltage Offset Correction: v_off_ini = 10.469 uV, v_off_fin = 1.769 uV 09:29:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.840 uVs 09:29:44 Integrated Voltage Measurement... 09:29:53 Voltage Offset Correction: v_off_ini = 24.236 uV, v_off_fin = 31.306 uV 09:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.482 uVs 09:29:53 Integrated Voltage Measurement... 09:30:02 Voltage Offset Correction: v_off_ini = 31.253 uV, v_off_fin = 16.233 uV 09:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.869 uVs 09:30:03 Integrated Voltage Measurement... 09:30:12 Voltage Offset Correction: v_off_ini = 41.143 uV, v_off_fin = 35.808 uV 09:30:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.277 uVs 09:30:14 I2X Average and RMS of Measurements VT = -75.964 +- 4.694 uVs I2X = 6.989 +- 0.432 uTm^2 09:30:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:30:22 Integrated Voltage Measurement... 09:30:31 Voltage Offset Correction: v_off_ini = 39.224 uV, v_off_fin = 22.927 uV 09:30:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.751 uVs 09:30:31 Integrated Voltage Measurement... 09:30:40 Voltage Offset Correction: v_off_ini = 21.388 uV, v_off_fin = 22.743 uV 09:30:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.264 uVs 09:30:40 Integrated Voltage Measurement... 09:30:49 Voltage Offset Correction: v_off_ini = 24.100 uV, v_off_fin = 25.844 uV 09:30:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.512 uVs 09:30:49 Integrated Voltage Measurement... 09:30:58 Voltage Offset Correction: v_off_ini = 8.512 uV, v_off_fin = 13.154 uV 09:30:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.554 uVs 09:30:58 Integrated Voltage Measurement... 09:31:07 Voltage Offset Correction: v_off_ini = 15.905 uV, v_off_fin = 6.877 uV 09:31:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.646 uVs 09:31:07 Integrated Voltage Measurement... 09:31:16 Voltage Offset Correction: v_off_ini = 10.840 uV, v_off_fin = 26.638 uV 09:31:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.312 uVs 09:31:18 I2Y Average and RMS of Measurements VT = -235.840 +- 5.429 uVs I2Y = -21.697 +- 0.499 uTm^2 09:31:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:31:27 Integrated Voltage Measurement... 09:31:36 Voltage Offset Correction: v_off_ini = 21.296 uV, v_off_fin = 14.359 uV 09:31:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.766 uVs 09:31:36 Integrated Voltage Measurement... 09:31:45 Voltage Offset Correction: v_off_ini = 8.190 uV, v_off_fin = 18.038 uV 09:31:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.038 uVs 09:31:45 Integrated Voltage Measurement... 09:31:54 Voltage Offset Correction: v_off_ini = 18.845 uV, v_off_fin = 10.944 uV 09:31:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.287 uVs 09:31:54 Integrated Voltage Measurement... 09:32:03 Voltage Offset Correction: v_off_ini = 17.259 uV, v_off_fin = 17.358 uV 09:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.551 uVs 09:32:03 Integrated Voltage Measurement... 09:32:12 Voltage Offset Correction: v_off_ini = 8.967 uV, v_off_fin = 14.705 uV 09:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.737 uVs 09:32:12 Integrated Voltage Measurement... 09:32:21 Voltage Offset Correction: v_off_ini = 32.747 uV, v_off_fin = 27.317 uV 09:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.545 uVs 09:32:25 I1X Average and RMS of Measurements VT = -40.821 +- 2.356 uVs I1X = 8.164 +- 0.471 uTm 09:32:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:32:32 Integrated Voltage Measurement... 09:32:41 Voltage Offset Correction: v_off_ini = 24.438 uV, v_off_fin = 19.121 uV 09:32:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.102 uVs 09:32:41 Integrated Voltage Measurement... 09:32:50 Voltage Offset Correction: v_off_ini = 36.078 uV, v_off_fin = 49.182 uV 09:32:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.264 uVs 09:32:50 Integrated Voltage Measurement... 09:32:59 Voltage Offset Correction: v_off_ini = 26.285 uV, v_off_fin = 28.772 uV 09:32:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.000 uVs 09:32:59 Integrated Voltage Measurement... 09:33:08 Voltage Offset Correction: v_off_ini = 44.160 uV, v_off_fin = 38.154 uV 09:33:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.120 uVs 09:33:08 Integrated Voltage Measurement... 09:33:17 Voltage Offset Correction: v_off_ini = 28.725 uV, v_off_fin = 28.643 uV 09:33:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.470 uVs 09:33:17 Integrated Voltage Measurement... 09:33:26 Voltage Offset Correction: v_off_ini = 33.791 uV, v_off_fin = 50.204 uV 09:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.306 uVs 09:33:30 I1Y Average and RMS of Measurements VT = -167.544 +- 6.940 uVs I1Y = -33.509 +- 1.388 uTm 09:33:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:33:38 Integrated Voltage Measurement... 09:33:47 Voltage Offset Correction: v_off_ini = 40.846 uV, v_off_fin = 41.627 uV 09:33:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.160 uVs 09:33:47 Integrated Voltage Measurement... 09:33:56 Voltage Offset Correction: v_off_ini = 62.738 uV, v_off_fin = 66.436 uV 09:33:56 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 53.139 uVs 09:33:56 Integrated Voltage Measurement... 09:34:05 Voltage Offset Correction: v_off_ini = 49.009 uV, v_off_fin = 31.773 uV 09:34:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.194 uVs 09:34:05 Integrated Voltage Measurement... 09:34:14 Voltage Offset Correction: v_off_ini = 50.296 uV, v_off_fin = 49.544 uV 09:34:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.917 uVs 09:34:14 Integrated Voltage Measurement... 09:34:23 Voltage Offset Correction: v_off_ini = 42.362 uV, v_off_fin = 61.532 uV 09:34:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.480 uVs 09:34:23 Integrated Voltage Measurement... 09:34:32 Voltage Offset Correction: v_off_ini = 67.962 uV, v_off_fin = 72.418 uV 09:34:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.003 uVs 09:34:35 I2X Average and RMS of Measurements VT = -52.982 +- 1.373 uVs I2X = 4.875 +- 0.126 uTm^2 09:34:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:34:42 Integrated Voltage Measurement... 09:34:51 Voltage Offset Correction: v_off_ini = 64.024 uV, v_off_fin = 49.120 uV 09:34:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.771 uVs 09:34:52 Integrated Voltage Measurement... 09:35:00 Voltage Offset Correction: v_off_ini = 58.980 uV, v_off_fin = 57.786 uV 09:35:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.696 uVs 09:35:01 Integrated Voltage Measurement... 09:35:10 Voltage Offset Correction: v_off_ini = 54.867 uV, v_off_fin = 62.055 uV 09:35:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.982 uVs 09:35:10 Integrated Voltage Measurement... 09:35:19 Voltage Offset Correction: v_off_ini = 61.035 uV, v_off_fin = 68.075 uV 09:35:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.263 uVs 09:35:19 Integrated Voltage Measurement... 09:35:28 Voltage Offset Correction: v_off_ini = 75.485 uV, v_off_fin = 75.837 uV 09:35:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.165 uVs 09:35:28 Integrated Voltage Measurement... 09:35:37 Voltage Offset Correction: v_off_ini = 89.133 uV, v_off_fin = 92.434 uV 09:35:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.719 uVs 09:35:39 I2Y Average and RMS of Measurements VT = -237.433 +- 5.601 uVs I2Y = -21.844 +- 0.515 uTm^2 09:35:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:35:48 Integrated Voltage Measurement... 09:35:57 Voltage Offset Correction: v_off_ini = 87.309 uV, v_off_fin = 77.084 uV 09:35:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.195 uVs 09:35:57 Integrated Voltage Measurement... 09:36:06 Voltage Offset Correction: v_off_ini = 89.075 uV, v_off_fin = 93.720 uV 09:36:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 13.973 uVs 09:36:06 Integrated Voltage Measurement... 09:36:15 Voltage Offset Correction: v_off_ini = 78.755 uV, v_off_fin = 73.775 uV 09:36:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.171 uVs 09:36:15 Integrated Voltage Measurement... 09:36:24 Voltage Offset Correction: v_off_ini = 78.466 uV, v_off_fin = 87.200 uV 09:36:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.690 uVs 09:36:24 Integrated Voltage Measurement... 09:36:33 Voltage Offset Correction: v_off_ini = 74.073 uV, v_off_fin = 75.156 uV 09:36:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.960 uVs 09:36:33 Integrated Voltage Measurement... 09:36:42 Voltage Offset Correction: v_off_ini = 71.955 uV, v_off_fin = 93.034 uV 09:36:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.530 uVs 09:36:46 I1X Average and RMS of Measurements VT = -28.253 +- 4.809 uVs I1X = 5.651 +- 0.962 uTm 09:36:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:36:53 Integrated Voltage Measurement... 09:37:02 Voltage Offset Correction: v_off_ini = 91.314 uV, v_off_fin = 75.594 uV 09:37:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.327 uVs 09:37:02 Integrated Voltage Measurement... 09:37:11 Voltage Offset Correction: v_off_ini = 81.022 uV, v_off_fin = 105.886 uV 09:37:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.824 uVs 09:37:11 Integrated Voltage Measurement... 09:37:20 Voltage Offset Correction: v_off_ini = 98.694 uV, v_off_fin = 89.626 uV 09:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.510 uVs 09:37:20 Integrated Voltage Measurement... 09:37:29 Voltage Offset Correction: v_off_ini = 106.203 uV, v_off_fin = 123.472 uV 09:37:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.122 uVs 09:37:29 Integrated Voltage Measurement... 09:37:38 Voltage Offset Correction: v_off_ini = 104.672 uV, v_off_fin = 101.546 uV 09:37:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.614 uVs 09:37:38 Integrated Voltage Measurement... 09:37:47 Voltage Offset Correction: v_off_ini = 91.229 uV, v_off_fin = 99.696 uV 09:37:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.196 uVs 09:37:51 I1Y Average and RMS of Measurements VT = -165.766 +- 1.910 uVs I1Y = -33.153 +- 0.382 uTm 09:37:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:37:59 Integrated Voltage Measurement... 09:38:08 Voltage Offset Correction: v_off_ini = 85.361 uV, v_off_fin = 89.336 uV 09:38:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -42.798 uVs 09:38:08 Integrated Voltage Measurement... 09:38:17 Voltage Offset Correction: v_off_ini = 103.672 uV, v_off_fin = 104.854 uV 09:38:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.731 uVs 09:38:17 Integrated Voltage Measurement... 09:38:26 Voltage Offset Correction: v_off_ini = 97.311 uV, v_off_fin = 82.742 uV 09:38:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.778 uVs 09:38:26 Integrated Voltage Measurement... 09:38:35 Voltage Offset Correction: v_off_ini = 99.528 uV, v_off_fin = 104.323 uV 09:38:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 32.818 uVs 09:38:35 Integrated Voltage Measurement... 09:38:44 Voltage Offset Correction: v_off_ini = 103.319 uV, v_off_fin = 94.722 uV 09:38:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.094 uVs 09:38:44 Integrated Voltage Measurement... 09:38:53 Voltage Offset Correction: v_off_ini = 103.370 uV, v_off_fin = 113.363 uV 09:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.344 uVs 09:38:56 I2X Average and RMS of Measurements VT = -46.260 +- 7.843 uVs I2X = 4.256 +- 0.722 uTm^2 09:39:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:39:03 Integrated Voltage Measurement... 09:39:12 Voltage Offset Correction: v_off_ini = 96.934 uV, v_off_fin = 97.354 uV 09:39:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.283 uVs 09:39:12 Integrated Voltage Measurement... 09:39:21 Voltage Offset Correction: v_off_ini = 113.329 uV, v_off_fin = 106.819 uV 09:39:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.368 uVs 09:39:21 Integrated Voltage Measurement... 09:39:30 Voltage Offset Correction: v_off_ini = 102.026 uV, v_off_fin = 110.353 uV 09:39:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.034 uVs 09:39:30 Integrated Voltage Measurement... 09:39:39 Voltage Offset Correction: v_off_ini = 100.123 uV, v_off_fin = 92.356 uV 09:39:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.955 uVs 09:39:39 Integrated Voltage Measurement... 09:39:48 Voltage Offset Correction: v_off_ini = 98.784 uV, v_off_fin = 92.192 uV 09:39:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.261 uVs 09:39:48 Integrated Voltage Measurement... 09:39:57 Voltage Offset Correction: v_off_ini = 95.938 uV, v_off_fin = 93.352 uV 09:39:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.688 uVs 09:40:00 I2Y Average and RMS of Measurements VT = -234.598 +- 12.257 uVs I2Y = -21.583 +- 1.128 uTm^2 09:40:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:40:12 Integrated Voltage Measurement... 09:40:21 Voltage Offset Correction: v_off_ini = 92.939 uV, v_off_fin = 88.043 uV 09:40:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -28.292 uVs 09:40:21 Integrated Voltage Measurement... 09:40:30 Voltage Offset Correction: v_off_ini = 100.428 uV, v_off_fin = 104.188 uV 09:40:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 15.962 uVs 09:40:30 Integrated Voltage Measurement... 09:40:39 Voltage Offset Correction: v_off_ini = 97.903 uV, v_off_fin = 105.460 uV 09:40:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.732 uVs 09:40:39 Integrated Voltage Measurement... 09:40:48 Voltage Offset Correction: v_off_ini = 110.948 uV, v_off_fin = 112.950 uV 09:40:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 60.097 uVs 09:40:48 Integrated Voltage Measurement... 09:40:57 Voltage Offset Correction: v_off_ini = 108.934 uV, v_off_fin = 108.596 uV 09:40:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.083 uVs 09:40:57 Integrated Voltage Measurement... 09:41:06 Voltage Offset Correction: v_off_ini = 98.835 uV, v_off_fin = 95.867 uV 09:41:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.054 uVs 09:41:10 I1X Average and RMS of Measurements VT = -32.870 +- 8.897 uVs I1X = 6.574 +- 1.779 uTm 09:41:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:41:17 Integrated Voltage Measurement... 09:41:26 Voltage Offset Correction: v_off_ini = 110.897 uV, v_off_fin = 102.787 uV 09:41:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.695 uVs 09:41:26 Integrated Voltage Measurement... 09:41:35 Voltage Offset Correction: v_off_ini = 109.807 uV, v_off_fin = 111.235 uV 09:41:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.179 uVs 09:41:35 Integrated Voltage Measurement... 09:41:44 Voltage Offset Correction: v_off_ini = 104.686 uV, v_off_fin = 97.174 uV 09:41:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.434 uVs 09:41:44 Integrated Voltage Measurement... 09:41:53 Voltage Offset Correction: v_off_ini = 122.647 uV, v_off_fin = 121.854 uV 09:41:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.427 uVs 09:41:53 Integrated Voltage Measurement... 09:42:02 Voltage Offset Correction: v_off_ini = 114.690 uV, v_off_fin = 100.094 uV 09:42:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.951 uVs 09:42:02 Integrated Voltage Measurement... 09:42:11 Voltage Offset Correction: v_off_ini = 117.773 uV, v_off_fin = 123.707 uV 09:42:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.090 uVs 09:42:15 I1Y Average and RMS of Measurements VT = -180.796 +- 4.452 uVs I1Y = -36.159 +- 0.890 uTm 09:42:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:42:20 Integrated Voltage Measurement... 09:42:29 Voltage Offset Correction: v_off_ini = 113.332 uV, v_off_fin = 111.053 uV 09:42:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -38.756 uVs 09:42:29 Integrated Voltage Measurement... 09:42:38 Voltage Offset Correction: v_off_ini = 119.962 uV, v_off_fin = 126.946 uV 09:42:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.142 uVs 09:42:38 Integrated Voltage Measurement... 09:42:47 Voltage Offset Correction: v_off_ini = 130.161 uV, v_off_fin = 116.611 uV 09:42:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.670 uVs 09:42:47 Integrated Voltage Measurement... 09:42:56 Voltage Offset Correction: v_off_ini = 118.293 uV, v_off_fin = 127.125 uV 09:42:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.281 uVs 09:42:56 Integrated Voltage Measurement... 09:43:05 Voltage Offset Correction: v_off_ini = 125.428 uV, v_off_fin = 109.609 uV 09:43:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.892 uVs 09:43:05 Integrated Voltage Measurement... 09:43:14 Voltage Offset Correction: v_off_ini = 110.621 uV, v_off_fin = 143.814 uV 09:43:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.683 uVs 09:43:17 I2X Average and RMS of Measurements VT = -57.071 +- 9.530 uVs I2X = 5.250 +- 0.877 uTm^2 09:43:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:43:22 Integrated Voltage Measurement... 09:43:31 Voltage Offset Correction: v_off_ini = 113.633 uV, v_off_fin = 117.933 uV 09:43:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.500 uVs 09:43:31 Integrated Voltage Measurement... 09:43:40 Voltage Offset Correction: v_off_ini = 112.282 uV, v_off_fin = 115.924 uV 09:43:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.737 uVs 09:43:40 Integrated Voltage Measurement... 09:43:49 Voltage Offset Correction: v_off_ini = 109.106 uV, v_off_fin = 120.127 uV 09:43:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.653 uVs 09:43:49 Integrated Voltage Measurement... 09:43:58 Voltage Offset Correction: v_off_ini = 115.821 uV, v_off_fin = 118.848 uV 09:43:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.577 uVs 09:43:58 Integrated Voltage Measurement... 09:44:07 Voltage Offset Correction: v_off_ini = 117.477 uV, v_off_fin = 111.201 uV 09:44:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.050 uVs 09:44:07 Integrated Voltage Measurement... 09:44:16 Voltage Offset Correction: v_off_ini = 115.316 uV, v_off_fin = 115.362 uV 09:44:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.124 uVs 09:44:18 I2Y Average and RMS of Measurements VT = -252.940 +- 3.807 uVs I2Y = -23.270 +- 0.350 uTm^2 09:44:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:44:27 Integrated Voltage Measurement... 09:44:36 Voltage Offset Correction: v_off_ini = 121.822 uV, v_off_fin = 106.628 uV 09:44:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.562 uVs 09:44:36 Integrated Voltage Measurement... 09:44:45 Voltage Offset Correction: v_off_ini = 103.074 uV, v_off_fin = 110.841 uV 09:44:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.502 uVs 09:44:45 Integrated Voltage Measurement... 09:44:54 Voltage Offset Correction: v_off_ini = 116.008 uV, v_off_fin = 119.779 uV 09:44:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.650 uVs 09:44:54 Integrated Voltage Measurement... 09:45:03 Voltage Offset Correction: v_off_ini = 118.580 uV, v_off_fin = 123.922 uV 09:45:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.501 uVs 09:45:03 Integrated Voltage Measurement... 09:45:12 Voltage Offset Correction: v_off_ini = 111.601 uV, v_off_fin = 110.634 uV 09:45:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.464 uVs 09:45:12 Integrated Voltage Measurement... 09:45:21 Voltage Offset Correction: v_off_ini = 111.762 uV, v_off_fin = 123.290 uV 09:45:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.480 uVs 09:45:25 I1X Average and RMS of Measurements VT = -43.860 +- 3.498 uVs I1X = 8.772 +- 0.700 uTm 09:45:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:45:32 Integrated Voltage Measurement... 09:45:41 Voltage Offset Correction: v_off_ini = 118.186 uV, v_off_fin = 114.472 uV 09:45:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.236 uVs 09:45:41 Integrated Voltage Measurement... 09:45:50 Voltage Offset Correction: v_off_ini = 99.207 uV, v_off_fin = 113.936 uV 09:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.896 uVs 09:45:50 Integrated Voltage Measurement... 09:45:59 Voltage Offset Correction: v_off_ini = 105.206 uV, v_off_fin = 101.615 uV 09:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.225 uVs 09:45:59 Integrated Voltage Measurement... 09:46:08 Voltage Offset Correction: v_off_ini = 108.787 uV, v_off_fin = 111.723 uV 09:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.000 uVs 09:46:08 Integrated Voltage Measurement... 09:46:17 Voltage Offset Correction: v_off_ini = 109.829 uV, v_off_fin = 103.548 uV 09:46:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.294 uVs 09:46:17 Integrated Voltage Measurement... 09:46:26 Voltage Offset Correction: v_off_ini = 113.125 uV, v_off_fin = 122.228 uV 09:46:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.279 uVs 09:46:30 I1Y Average and RMS of Measurements VT = -176.822 +- 10.528 uVs I1Y = -35.364 +- 2.106 uTm 09:46:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:46:35 Integrated Voltage Measurement... 09:46:44 Voltage Offset Correction: v_off_ini = 115.153 uV, v_off_fin = 109.998 uV 09:46:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.300 uVs 09:46:44 Integrated Voltage Measurement... 09:46:53 Voltage Offset Correction: v_off_ini = 122.748 uV, v_off_fin = 120.961 uV 09:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.788 uVs 09:46:53 Integrated Voltage Measurement... 09:47:02 Voltage Offset Correction: v_off_ini = 119.390 uV, v_off_fin = 117.261 uV 09:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.786 uVs 09:47:02 Integrated Voltage Measurement... 09:47:11 Voltage Offset Correction: v_off_ini = 127.171 uV, v_off_fin = 130.278 uV 09:47:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.583 uVs 09:47:11 Integrated Voltage Measurement... 09:47:20 Voltage Offset Correction: v_off_ini = 131.744 uV, v_off_fin = 119.523 uV 09:47:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.273 uVs 09:47:20 Integrated Voltage Measurement... 09:47:29 Voltage Offset Correction: v_off_ini = 140.887 uV, v_off_fin = 137.123 uV 09:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.262 uVs 09:47:32 I2X Average and RMS of Measurements VT = -70.499 +- 4.483 uVs I2X = 6.486 +- 0.412 uTm^2 09:47:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:47:37 Integrated Voltage Measurement... 09:47:46 Voltage Offset Correction: v_off_ini = 138.247 uV, v_off_fin = 137.461 uV 09:47:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.011 uVs 09:47:46 Integrated Voltage Measurement... 09:47:55 Voltage Offset Correction: v_off_ini = 153.154 uV, v_off_fin = 150.175 uV 09:47:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.098 uVs 09:47:55 Integrated Voltage Measurement... 09:48:04 Voltage Offset Correction: v_off_ini = 150.596 uV, v_off_fin = 156.595 uV 09:48:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.204 uVs 09:48:04 Integrated Voltage Measurement... 09:48:13 Voltage Offset Correction: v_off_ini = 149.959 uV, v_off_fin = 166.437 uV 09:48:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.094 uVs 09:48:13 Integrated Voltage Measurement... 09:48:22 Voltage Offset Correction: v_off_ini = 166.687 uV, v_off_fin = 158.724 uV 09:48:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.670 uVs 09:48:22 Integrated Voltage Measurement... 09:48:31 Voltage Offset Correction: v_off_ini = 162.885 uV, v_off_fin = 153.420 uV 09:48:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.808 uVs 09:48:34 I2Y Average and RMS of Measurements VT = -248.314 +- 8.584 uVs I2Y = -22.845 +- 0.790 uTm^2 09:48:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:48:42 Integrated Voltage Measurement... 09:48:51 Voltage Offset Correction: v_off_ini = 153.937 uV, v_off_fin = 151.808 uV 09:48:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.703 uVs 09:48:51 Integrated Voltage Measurement... 09:49:00 Voltage Offset Correction: v_off_ini = 151.575 uV, v_off_fin = 165.104 uV 09:49:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 58.281 uVs 09:49:00 Integrated Voltage Measurement... 09:49:09 Voltage Offset Correction: v_off_ini = 150.259 uV, v_off_fin = 164.468 uV 09:49:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.198 uVs 09:49:09 Integrated Voltage Measurement... 09:49:18 Voltage Offset Correction: v_off_ini = 178.072 uV, v_off_fin = 180.681 uV 09:49:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.386 uVs 09:49:18 Integrated Voltage Measurement... 09:49:27 Voltage Offset Correction: v_off_ini = 165.285 uV, v_off_fin = 168.046 uV 09:49:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.232 uVs 09:49:27 Integrated Voltage Measurement... 09:49:36 Voltage Offset Correction: v_off_ini = 175.501 uV, v_off_fin = 176.722 uV 09:49:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.263 uVs 09:49:40 I1X Average and RMS of Measurements VT = -51.177 +- 5.589 uVs I1X = 10.236 +- 1.119 uTm 09:49:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:49:47 Integrated Voltage Measurement... 09:49:56 Voltage Offset Correction: v_off_ini = 180.666 uV, v_off_fin = 156.456 uV 09:49:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -171.893 uVs 09:49:56 Integrated Voltage Measurement... 09:50:05 Voltage Offset Correction: v_off_ini = 180.789 uV, v_off_fin = 178.493 uV 09:50:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.773 uVs 09:50:05 Integrated Voltage Measurement... 09:50:14 Voltage Offset Correction: v_off_ini = 171.260 uV, v_off_fin = 154.076 uV 09:50:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.042 uVs 09:50:14 Integrated Voltage Measurement... 09:50:23 Voltage Offset Correction: v_off_ini = 153.028 uV, v_off_fin = 172.785 uV 09:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.150 uVs 09:50:23 Integrated Voltage Measurement... 09:50:32 Voltage Offset Correction: v_off_ini = 167.327 uV, v_off_fin = 148.588 uV 09:50:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.940 uVs 09:50:32 Integrated Voltage Measurement... 09:50:41 Voltage Offset Correction: v_off_ini = 152.402 uV, v_off_fin = 164.398 uV 09:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.155 uVs 09:50:45 I1Y Average and RMS of Measurements VT = -167.326 +- 1.449 uVs I1Y = -33.467 +- 0.289 uTm 09:50:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:50:50 Integrated Voltage Measurement... 09:50:59 Voltage Offset Correction: v_off_ini = 162.830 uV, v_off_fin = 151.046 uV 09:50:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.908 uVs 09:50:59 Integrated Voltage Measurement... 09:51:08 Voltage Offset Correction: v_off_ini = 159.255 uV, v_off_fin = 174.448 uV 09:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.457 uVs 09:51:08 Integrated Voltage Measurement... 09:51:17 Voltage Offset Correction: v_off_ini = 161.825 uV, v_off_fin = 153.761 uV 09:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.676 uVs 09:51:17 Integrated Voltage Measurement... 09:51:26 Voltage Offset Correction: v_off_ini = 154.304 uV, v_off_fin = 163.034 uV 09:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.479 uVs 09:51:26 Integrated Voltage Measurement... 09:51:35 Voltage Offset Correction: v_off_ini = 159.437 uV, v_off_fin = 156.764 uV 09:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.320 uVs 09:51:35 Integrated Voltage Measurement... 09:51:44 Voltage Offset Correction: v_off_ini = 159.229 uV, v_off_fin = 158.561 uV 09:51:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.613 uVs 09:51:47 I2X Average and RMS of Measurements VT = -79.742 +- 2.558 uVs I2X = 7.336 +- 0.235 uTm^2 09:51:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:51:52 Integrated Voltage Measurement... 09:52:01 Voltage Offset Correction: v_off_ini = 156.731 uV, v_off_fin = 153.741 uV 09:52:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -243.385 uVs 09:52:01 Integrated Voltage Measurement... 09:52:10 Voltage Offset Correction: v_off_ini = 146.130 uV, v_off_fin = 140.958 uV 09:52:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 238.094 uVs 09:52:10 Integrated Voltage Measurement... 09:52:19 Voltage Offset Correction: v_off_ini = 157.274 uV, v_off_fin = 138.830 uV 09:52:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.321 uVs 09:52:19 Integrated Voltage Measurement... 09:52:28 Voltage Offset Correction: v_off_ini = 140.422 uV, v_off_fin = 140.907 uV 09:52:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.121 uVs 09:52:28 Integrated Voltage Measurement... 09:52:37 Voltage Offset Correction: v_off_ini = 150.711 uV, v_off_fin = 149.904 uV 09:52:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.013 uVs 09:52:37 Integrated Voltage Measurement... 09:52:46 Voltage Offset Correction: v_off_ini = 147.643 uV, v_off_fin = 163.856 uV 09:52:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.384 uVs 09:52:48 I2Y Average and RMS of Measurements VT = -233.720 +- 5.364 uVs I2Y = -21.502 +- 0.493 uTm^2 09:52:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:52:57 Integrated Voltage Measurement... 09:53:06 Voltage Offset Correction: v_off_ini = 169.897 uV, v_off_fin = 154.650 uV 09:53:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -45.636 uVs 09:53:06 Integrated Voltage Measurement... 09:53:15 Voltage Offset Correction: v_off_ini = 144.131 uV, v_off_fin = 150.254 uV 09:53:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.565 uVs 09:53:15 Integrated Voltage Measurement... 09:53:24 Voltage Offset Correction: v_off_ini = 160.414 uV, v_off_fin = 157.658 uV 09:53:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.006 uVs 09:53:24 Integrated Voltage Measurement... 09:53:33 Voltage Offset Correction: v_off_ini = 174.734 uV, v_off_fin = 178.072 uV 09:53:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.975 uVs 09:53:33 Integrated Voltage Measurement... 09:53:42 Voltage Offset Correction: v_off_ini = 160.710 uV, v_off_fin = 165.979 uV 09:53:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.834 uVs 09:53:42 Integrated Voltage Measurement... 09:53:51 Voltage Offset Correction: v_off_ini = 181.681 uV, v_off_fin = 180.148 uV 09:53:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.801 uVs 09:53:55 I1X Average and RMS of Measurements VT = -40.469 +- 7.722 uVs I1X = 8.094 +- 1.545 uTm 09:53:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:54:02 Integrated Voltage Measurement... 09:54:11 Voltage Offset Correction: v_off_ini = 179.889 uV, v_off_fin = 166.463 uV 09:54:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -154.521 uVs 09:54:11 Integrated Voltage Measurement... 09:54:20 Voltage Offset Correction: v_off_ini = 176.569 uV, v_off_fin = 191.829 uV 09:54:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.568 uVs 09:54:20 Integrated Voltage Measurement... 09:54:29 Voltage Offset Correction: v_off_ini = 185.155 uV, v_off_fin = 174.748 uV 09:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.677 uVs 09:54:29 Integrated Voltage Measurement... 09:54:38 Voltage Offset Correction: v_off_ini = 185.058 uV, v_off_fin = 194.744 uV 09:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 165.316 uVs 09:54:38 Integrated Voltage Measurement... 09:54:47 Voltage Offset Correction: v_off_ini = 189.898 uV, v_off_fin = 177.963 uV 09:54:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.743 uVs 09:54:47 Integrated Voltage Measurement... 09:54:56 Voltage Offset Correction: v_off_ini = 199.200 uV, v_off_fin = 191.376 uV 09:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 158.282 uVs 09:55:00 I1Y Average and RMS of Measurements VT = -163.518 +- 1.474 uVs I1Y = -32.702 +- 0.294 uTm 09:55:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:55:05 Integrated Voltage Measurement... 09:55:14 Voltage Offset Correction: v_off_ini = 188.379 uV, v_off_fin = 180.122 uV 09:55:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.204 uVs 09:55:14 Integrated Voltage Measurement... 09:55:23 Voltage Offset Correction: v_off_ini = 202.680 uV, v_off_fin = 211.173 uV 09:55:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.051 uVs 09:55:23 Integrated Voltage Measurement... 09:55:32 Voltage Offset Correction: v_off_ini = 205.104 uV, v_off_fin = 196.908 uV 09:55:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.050 uVs 09:55:32 Integrated Voltage Measurement... 09:55:41 Voltage Offset Correction: v_off_ini = 201.830 uV, v_off_fin = 202.358 uV 09:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.922 uVs 09:55:41 Integrated Voltage Measurement... 09:55:50 Voltage Offset Correction: v_off_ini = 191.240 uV, v_off_fin = 186.868 uV 09:55:50 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -73.526 uVs 09:55:50 Integrated Voltage Measurement... 09:55:59 Voltage Offset Correction: v_off_ini = 198.928 uV, v_off_fin = 207.426 uV 09:55:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.909 uVs 09:56:02 I2X Average and RMS of Measurements VT = -70.277 +- 2.561 uVs I2X = 6.466 +- 0.235 uTm^2 09:56:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 09:56:07 Integrated Voltage Measurement... 09:56:16 Voltage Offset Correction: v_off_ini = 200.259 uV, v_off_fin = 204.109 uV 09:56:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.334 uVs 09:56:16 Integrated Voltage Measurement... 09:56:25 Voltage Offset Correction: v_off_ini = 188.099 uV, v_off_fin = 189.889 uV 09:56:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 235.395 uVs 09:56:25 Integrated Voltage Measurement... 09:56:34 Voltage Offset Correction: v_off_ini = 201.005 uV, v_off_fin = 190.974 uV 09:56:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.524 uVs 09:56:34 Integrated Voltage Measurement... 09:56:43 Voltage Offset Correction: v_off_ini = 202.230 uV, v_off_fin = 203.069 uV 09:56:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.947 uVs 09:56:43 Integrated Voltage Measurement... 09:56:52 Voltage Offset Correction: v_off_ini = 210.941 uV, v_off_fin = 209.012 uV 09:56:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.358 uVs 09:56:52 Integrated Voltage Measurement... 09:57:01 Voltage Offset Correction: v_off_ini = 202.798 uV, v_off_fin = 196.964 uV 09:57:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.957 uVs 09:57:03 I2Y Average and RMS of Measurements VT = -232.252 +- 1.153 uVs I2Y = -21.368 +- 0.107 uTm^2 09:57:07 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:57:12 Integrated Voltage Measurement... 09:57:21 Voltage Offset Correction: v_off_ini = 194.184 uV, v_off_fin = 201.124 uV 09:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.699 uVs 09:57:21 Integrated Voltage Measurement... 09:57:30 Voltage Offset Correction: v_off_ini = 202.193 uV, v_off_fin = 202.041 uV 09:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.822 uVs 09:57:30 Integrated Voltage Measurement... 09:57:39 Voltage Offset Correction: v_off_ini = 203.217 uV, v_off_fin = 200.928 uV 09:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.008 uVs 09:57:39 Integrated Voltage Measurement... 09:57:48 Voltage Offset Correction: v_off_ini = 195.853 uV, v_off_fin = 210.385 uV 09:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.800 uVs 09:57:48 Integrated Voltage Measurement... 09:57:57 Voltage Offset Correction: v_off_ini = 198.661 uV, v_off_fin = 182.071 uV 09:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.091 uVs 09:57:57 Integrated Voltage Measurement... 09:58:06 Voltage Offset Correction: v_off_ini = 190.507 uV, v_off_fin = 201.997 uV 09:58:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.612 uVs 09:58:10 I1X Average and RMS of Measurements VT = -47.005 +- 2.842 uVs I1X = 9.401 +- 0.568 uTm 09:58:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:58:17 Integrated Voltage Measurement... 09:58:26 Voltage Offset Correction: v_off_ini = 204.335 uV, v_off_fin = 192.243 uV 09:58:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.996 uVs 09:58:26 Integrated Voltage Measurement... 09:58:35 Voltage Offset Correction: v_off_ini = 190.731 uV, v_off_fin = 211.324 uV 09:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 149.867 uVs 09:58:35 Integrated Voltage Measurement... 09:58:44 Voltage Offset Correction: v_off_ini = 205.590 uV, v_off_fin = 194.617 uV 09:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.032 uVs 09:58:44 Integrated Voltage Measurement... 09:58:53 Voltage Offset Correction: v_off_ini = 203.109 uV, v_off_fin = 202.791 uV 09:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 152.810 uVs 09:58:53 Integrated Voltage Measurement... 09:59:02 Voltage Offset Correction: v_off_ini = 196.223 uV, v_off_fin = 188.187 uV 09:59:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -125.594 uVs 09:59:02 Integrated Voltage Measurement... 09:59:11 Voltage Offset Correction: v_off_ini = 195.594 uV, v_off_fin = 203.497 uV 09:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 148.856 uVs 09:59:15 I1Y Average and RMS of Measurements VT = -150.859 +- 9.643 uVs I1Y = -30.170 +- 1.927 uTm 09:59:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 09:59:20 Integrated Voltage Measurement... 09:59:29 Voltage Offset Correction: v_off_ini = 209.283 uV, v_off_fin = 197.103 uV 09:59:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.353 uVs 09:59:29 Integrated Voltage Measurement... 09:59:38 Voltage Offset Correction: v_off_ini = 188.545 uV, v_off_fin = 204.908 uV 09:59:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.084 uVs 09:59:38 Integrated Voltage Measurement... 09:59:47 Voltage Offset Correction: v_off_ini = 201.450 uV, v_off_fin = 193.109 uV 09:59:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.035 uVs 09:59:47 Integrated Voltage Measurement... 09:59:56 Voltage Offset Correction: v_off_ini = 193.327 uV, v_off_fin = 199.636 uV 09:59:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.942 uVs 09:59:56 Integrated Voltage Measurement... 10:00:05 Voltage Offset Correction: v_off_ini = 199.589 uV, v_off_fin = 185.409 uV 10:00:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.430 uVs 10:00:05 Integrated Voltage Measurement... 10:00:14 Voltage Offset Correction: v_off_ini = 189.827 uV, v_off_fin = 210.020 uV 10:00:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.004 uVs 10:00:17 I2X Average and RMS of Measurements VT = -71.141 +- 10.699 uVs I2X = 6.545 +- 0.984 uTm^2 10:00:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:00:22 Integrated Voltage Measurement... 10:00:31 Voltage Offset Correction: v_off_ini = 196.610 uV, v_off_fin = 184.523 uV 10:00:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.360 uVs 10:00:31 Integrated Voltage Measurement... 10:00:40 Voltage Offset Correction: v_off_ini = 194.813 uV, v_off_fin = 198.887 uV 10:00:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.019 uVs 10:00:40 Integrated Voltage Measurement... 10:00:49 Voltage Offset Correction: v_off_ini = 201.767 uV, v_off_fin = 200.452 uV 10:00:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.862 uVs 10:00:49 Integrated Voltage Measurement... 10:00:58 Voltage Offset Correction: v_off_ini = 191.379 uV, v_off_fin = 205.989 uV 10:00:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.529 uVs 10:00:58 Integrated Voltage Measurement... 10:01:07 Voltage Offset Correction: v_off_ini = 219.013 uV, v_off_fin = 215.777 uV 10:01:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.052 uVs 10:01:07 Integrated Voltage Measurement... 10:01:16 Voltage Offset Correction: v_off_ini = 208.124 uV, v_off_fin = 206.824 uV 10:01:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.618 uVs 10:01:18 I2Y Average and RMS of Measurements VT = -218.240 +- 4.484 uVs I2Y = -20.078 +- 0.413 uTm^2 10:01:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:01:40 Integrated Voltage Measurement... 10:01:49 Voltage Offset Correction: v_off_ini = 216.363 uV, v_off_fin = 215.135 uV 10:01:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.981 uVs 10:01:49 Integrated Voltage Measurement... 10:01:58 Voltage Offset Correction: v_off_ini = 224.915 uV, v_off_fin = 219.183 uV 10:01:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 80.969 uVs 10:01:58 Integrated Voltage Measurement... 10:02:07 Voltage Offset Correction: v_off_ini = 218.263 uV, v_off_fin = 208.330 uV 10:02:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.351 uVs 10:02:07 Integrated Voltage Measurement... 10:02:16 Voltage Offset Correction: v_off_ini = 218.095 uV, v_off_fin = 229.104 uV 10:02:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.681 uVs 10:02:16 Integrated Voltage Measurement... 10:02:25 Voltage Offset Correction: v_off_ini = 225.578 uV, v_off_fin = 215.706 uV 10:02:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.746 uVs 10:02:25 Integrated Voltage Measurement... 10:02:34 Voltage Offset Correction: v_off_ini = 215.735 uV, v_off_fin = 220.468 uV 10:02:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.620 uVs 10:02:38 I1X Average and RMS of Measurements VT = -81.225 +- 2.103 uVs I1X = 16.245 +- 0.420 uTm 10:02:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:02:45 Integrated Voltage Measurement... 10:02:54 Voltage Offset Correction: v_off_ini = 208.261 uV, v_off_fin = 211.093 uV 10:02:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.614 uVs 10:02:54 Integrated Voltage Measurement... 10:03:03 Voltage Offset Correction: v_off_ini = 220.317 uV, v_off_fin = 231.350 uV 10:03:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.383 uVs 10:03:03 Integrated Voltage Measurement... 10:03:12 Voltage Offset Correction: v_off_ini = 239.139 uV, v_off_fin = 220.259 uV 10:03:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.225 uVs 10:03:12 Integrated Voltage Measurement... 10:03:21 Voltage Offset Correction: v_off_ini = 229.049 uV, v_off_fin = 235.456 uV 10:03:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.891 uVs 10:03:21 Integrated Voltage Measurement... 10:03:30 Voltage Offset Correction: v_off_ini = 220.480 uV, v_off_fin = 216.940 uV 10:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.152 uVs 10:03:30 Integrated Voltage Measurement... 10:03:39 Voltage Offset Correction: v_off_ini = 218.626 uV, v_off_fin = 230.875 uV 10:03:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.896 uVs 10:03:43 I1Y Average and RMS of Measurements VT = -213.027 +- 5.318 uVs I1Y = -42.605 +- 1.064 uTm 10:03:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:03:51 Integrated Voltage Measurement... 10:04:00 Voltage Offset Correction: v_off_ini = 229.712 uV, v_off_fin = 215.130 uV 10:04:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.573 uVs 10:04:00 Integrated Voltage Measurement... 10:04:09 Voltage Offset Correction: v_off_ini = 222.790 uV, v_off_fin = 244.000 uV 10:04:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.254 uVs 10:04:09 Integrated Voltage Measurement... 10:04:18 Voltage Offset Correction: v_off_ini = 218.418 uV, v_off_fin = 221.466 uV 10:04:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.396 uVs 10:04:18 Integrated Voltage Measurement... 10:04:27 Voltage Offset Correction: v_off_ini = 239.568 uV, v_off_fin = 243.171 uV 10:04:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.003 uVs 10:04:27 Integrated Voltage Measurement... 10:04:36 Voltage Offset Correction: v_off_ini = 234.576 uV, v_off_fin = 223.622 uV 10:04:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -114.972 uVs 10:04:36 Integrated Voltage Measurement... 10:04:45 Voltage Offset Correction: v_off_ini = 217.880 uV, v_off_fin = 226.305 uV 10:04:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.594 uVs 10:04:47 I2X Average and RMS of Measurements VT = -104.132 +- 3.939 uVs I2X = 9.580 +- 0.362 uTm^2 10:04:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:04:55 Integrated Voltage Measurement... 10:05:04 Voltage Offset Correction: v_off_ini = 221.388 uV, v_off_fin = 221.307 uV 10:05:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.356 uVs 10:05:04 Integrated Voltage Measurement... 10:05:13 Voltage Offset Correction: v_off_ini = 238.352 uV, v_off_fin = 229.325 uV 10:05:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.037 uVs 10:05:13 Integrated Voltage Measurement... 10:05:22 Voltage Offset Correction: v_off_ini = 235.519 uV, v_off_fin = 230.935 uV 10:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.944 uVs 10:05:22 Integrated Voltage Measurement... 10:05:31 Voltage Offset Correction: v_off_ini = 231.841 uV, v_off_fin = 233.254 uV 10:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.849 uVs 10:05:31 Integrated Voltage Measurement... 10:05:40 Voltage Offset Correction: v_off_ini = 239.518 uV, v_off_fin = 232.952 uV 10:05:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.114 uVs 10:05:40 Integrated Voltage Measurement... 10:05:49 Voltage Offset Correction: v_off_ini = 239.108 uV, v_off_fin = 241.932 uV 10:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.918 uVs 10:05:52 I2Y Average and RMS of Measurements VT = -271.536 +- 5.192 uVs I2Y = -24.981 +- 0.478 uTm^2 10:05:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:06:00 Integrated Voltage Measurement... 10:06:09 Voltage Offset Correction: v_off_ini = 244.230 uV, v_off_fin = 240.223 uV 10:06:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.784 uVs 10:06:09 Integrated Voltage Measurement... 10:06:18 Voltage Offset Correction: v_off_ini = 222.679 uV, v_off_fin = 241.898 uV 10:06:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.581 uVs 10:06:18 Integrated Voltage Measurement... 10:06:27 Voltage Offset Correction: v_off_ini = 237.924 uV, v_off_fin = 233.378 uV 10:06:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.953 uVs 10:06:27 Integrated Voltage Measurement... 10:06:36 Voltage Offset Correction: v_off_ini = 244.798 uV, v_off_fin = 249.691 uV 10:06:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.534 uVs 10:06:36 Integrated Voltage Measurement... 10:06:45 Voltage Offset Correction: v_off_ini = 256.042 uV, v_off_fin = 259.492 uV 10:06:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.231 uVs 10:06:45 Integrated Voltage Measurement... 10:06:54 Voltage Offset Correction: v_off_ini = 245.452 uV, v_off_fin = 237.355 uV 10:06:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.759 uVs 10:06:59 I1X Average and RMS of Measurements VT = -75.140 +- 11.070 uVs I1X = 15.028 +- 2.214 uTm 10:07:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:07:05 Integrated Voltage Measurement... 10:07:14 Voltage Offset Correction: v_off_ini = 257.994 uV, v_off_fin = 249.889 uV 10:07:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.213 uVs 10:07:14 Integrated Voltage Measurement... 10:07:23 Voltage Offset Correction: v_off_ini = 247.697 uV, v_off_fin = 263.744 uV 10:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.248 uVs 10:07:23 Integrated Voltage Measurement... 10:07:32 Voltage Offset Correction: v_off_ini = 261.086 uV, v_off_fin = 249.814 uV 10:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.594 uVs 10:07:32 Integrated Voltage Measurement... 10:07:41 Voltage Offset Correction: v_off_ini = 253.322 uV, v_off_fin = 271.156 uV 10:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.008 uVs 10:07:41 Integrated Voltage Measurement... 10:07:50 Voltage Offset Correction: v_off_ini = 272.475 uV, v_off_fin = 242.980 uV 10:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.444 uVs 10:07:50 Integrated Voltage Measurement... 10:07:59 Voltage Offset Correction: v_off_ini = 258.697 uV, v_off_fin = 263.449 uV 10:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.268 uVs 10:08:03 I1Y Average and RMS of Measurements VT = -213.129 +- 4.299 uVs I1Y = -42.626 +- 0.860 uTm 10:08:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:08:11 Integrated Voltage Measurement... 10:08:20 Voltage Offset Correction: v_off_ini = 260.040 uV, v_off_fin = 248.569 uV 10:08:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.518 uVs 10:08:20 Integrated Voltage Measurement... 10:08:29 Voltage Offset Correction: v_off_ini = 246.074 uV, v_off_fin = 260.488 uV 10:08:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.241 uVs 10:08:29 Integrated Voltage Measurement... 10:08:38 Voltage Offset Correction: v_off_ini = 245.932 uV, v_off_fin = 244.492 uV 10:08:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.101 uVs 10:08:38 Integrated Voltage Measurement... 10:08:47 Voltage Offset Correction: v_off_ini = 239.510 uV, v_off_fin = 251.165 uV 10:08:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.530 uVs 10:08:47 Integrated Voltage Measurement... 10:08:56 Voltage Offset Correction: v_off_ini = 247.972 uV, v_off_fin = 247.599 uV 10:08:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.860 uVs 10:08:56 Integrated Voltage Measurement... 10:09:05 Voltage Offset Correction: v_off_ini = 265.079 uV, v_off_fin = 269.033 uV 10:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.948 uVs 10:09:08 I2X Average and RMS of Measurements VT = -101.700 +- 7.809 uVs I2X = 9.356 +- 0.718 uTm^2 10:09:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:09:15 Integrated Voltage Measurement... 10:09:24 Voltage Offset Correction: v_off_ini = 266.036 uV, v_off_fin = 267.805 uV 10:09:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.345 uVs 10:09:24 Integrated Voltage Measurement... 10:09:33 Voltage Offset Correction: v_off_ini = 261.626 uV, v_off_fin = 265.782 uV 10:09:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.605 uVs 10:09:33 Integrated Voltage Measurement... 10:09:42 Voltage Offset Correction: v_off_ini = 266.757 uV, v_off_fin = 262.447 uV 10:09:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.425 uVs 10:09:42 Integrated Voltage Measurement... 10:09:51 Voltage Offset Correction: v_off_ini = 260.149 uV, v_off_fin = 262.614 uV 10:09:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.547 uVs 10:09:51 Integrated Voltage Measurement... 10:10:00 Voltage Offset Correction: v_off_ini = 255.430 uV, v_off_fin = 257.739 uV 10:10:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.932 uVs 10:10:00 Integrated Voltage Measurement... 10:10:09 Voltage Offset Correction: v_off_ini = 241.267 uV, v_off_fin = 245.130 uV 10:10:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.636 uVs 10:10:12 I2Y Average and RMS of Measurements VT = -276.581 +- 4.205 uVs I2Y = -25.445 +- 0.387 uTm^2 10:10:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:10:21 Integrated Voltage Measurement... 10:10:30 Voltage Offset Correction: v_off_ini = 260.741 uV, v_off_fin = 251.170 uV 10:10:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.841 uVs 10:10:30 Integrated Voltage Measurement... 10:10:39 Voltage Offset Correction: v_off_ini = 269.105 uV, v_off_fin = 280.024 uV 10:10:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.573 uVs 10:10:39 Integrated Voltage Measurement... 10:10:48 Voltage Offset Correction: v_off_ini = 264.369 uV, v_off_fin = 268.005 uV 10:10:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.094 uVs 10:10:48 Integrated Voltage Measurement... 10:10:57 Voltage Offset Correction: v_off_ini = 271.078 uV, v_off_fin = 266.375 uV 10:10:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.691 uVs 10:10:57 Integrated Voltage Measurement... 10:11:06 Voltage Offset Correction: v_off_ini = 279.116 uV, v_off_fin = 268.351 uV 10:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.146 uVs 10:11:06 Integrated Voltage Measurement... 10:11:15 Voltage Offset Correction: v_off_ini = 270.227 uV, v_off_fin = 273.844 uV 10:11:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.730 uVs 10:11:19 I1X Average and RMS of Measurements VT = -49.679 +- 7.375 uVs I1X = 9.936 +- 1.475 uTm 10:11:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:11:26 Integrated Voltage Measurement... 10:11:35 Voltage Offset Correction: v_off_ini = 276.996 uV, v_off_fin = 276.417 uV 10:11:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -205.528 uVs 10:11:35 Integrated Voltage Measurement... 10:11:44 Voltage Offset Correction: v_off_ini = 277.121 uV, v_off_fin = 280.781 uV 10:11:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.171 uVs 10:11:44 Integrated Voltage Measurement... 10:11:53 Voltage Offset Correction: v_off_ini = 270.540 uV, v_off_fin = 265.189 uV 10:11:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.068 uVs 10:11:53 Integrated Voltage Measurement... 10:12:02 Voltage Offset Correction: v_off_ini = 277.698 uV, v_off_fin = 288.231 uV 10:12:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.613 uVs 10:12:02 Integrated Voltage Measurement... 10:12:11 Voltage Offset Correction: v_off_ini = 272.251 uV, v_off_fin = 265.152 uV 10:12:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.383 uVs 10:12:11 Integrated Voltage Measurement... 10:12:20 Voltage Offset Correction: v_off_ini = 258.571 uV, v_off_fin = 287.071 uV 10:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.504 uVs 10:12:24 I1Y Average and RMS of Measurements VT = -192.711 +- 6.779 uVs I1Y = -38.544 +- 1.355 uTm 10:12:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:12:31 Integrated Voltage Measurement... 10:12:40 Voltage Offset Correction: v_off_ini = 286.210 uV, v_off_fin = 287.992 uV 10:12:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -91.315 uVs 10:12:41 Integrated Voltage Measurement... 10:12:49 Voltage Offset Correction: v_off_ini = 296.981 uV, v_off_fin = 311.540 uV 10:12:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.278 uVs 10:12:50 Integrated Voltage Measurement... 10:12:58 Voltage Offset Correction: v_off_ini = 294.472 uV, v_off_fin = 289.893 uV 10:12:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.989 uVs 10:12:59 Integrated Voltage Measurement... 10:13:07 Voltage Offset Correction: v_off_ini = 298.294 uV, v_off_fin = 309.152 uV 10:13:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.834 uVs 10:13:08 Integrated Voltage Measurement... 10:13:17 Voltage Offset Correction: v_off_ini = 303.231 uV, v_off_fin = 288.293 uV 10:13:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.512 uVs 10:13:17 Integrated Voltage Measurement... 10:13:26 Voltage Offset Correction: v_off_ini = 294.155 uV, v_off_fin = 307.364 uV 10:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.029 uVs 10:13:28 I2X Average and RMS of Measurements VT = -82.493 +- 2.189 uVs I2X = 7.589 +- 0.201 uTm^2 10:13:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:13:36 Integrated Voltage Measurement... 10:13:45 Voltage Offset Correction: v_off_ini = 292.073 uV, v_off_fin = 293.145 uV 10:13:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.862 uVs 10:13:45 Integrated Voltage Measurement... 10:13:54 Voltage Offset Correction: v_off_ini = 294.065 uV, v_off_fin = 275.297 uV 10:13:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.565 uVs 10:13:54 Integrated Voltage Measurement... 10:14:03 Voltage Offset Correction: v_off_ini = 277.438 uV, v_off_fin = 280.217 uV 10:14:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.188 uVs 10:14:03 Integrated Voltage Measurement... 10:14:12 Voltage Offset Correction: v_off_ini = 287.748 uV, v_off_fin = 286.461 uV 10:14:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.245 uVs 10:14:12 Integrated Voltage Measurement... 10:14:21 Voltage Offset Correction: v_off_ini = 280.943 uV, v_off_fin = 280.958 uV 10:14:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.588 uVs 10:14:21 Integrated Voltage Measurement... 10:14:30 Voltage Offset Correction: v_off_ini = 275.809 uV, v_off_fin = 274.476 uV 10:14:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.791 uVs 10:14:32 I2Y Average and RMS of Measurements VT = -260.373 +- 5.654 uVs I2Y = -23.954 +- 0.520 uTm^2 10:14:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:14:41 Integrated Voltage Measurement... 10:14:50 Voltage Offset Correction: v_off_ini = 281.091 uV, v_off_fin = 267.031 uV 10:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.804 uVs 10:14:50 Integrated Voltage Measurement... 10:14:59 Voltage Offset Correction: v_off_ini = 286.874 uV, v_off_fin = 281.139 uV 10:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.065 uVs 10:14:59 Integrated Voltage Measurement... 10:15:08 Voltage Offset Correction: v_off_ini = 272.493 uV, v_off_fin = 277.579 uV 10:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.842 uVs 10:15:08 Integrated Voltage Measurement... 10:15:17 Voltage Offset Correction: v_off_ini = 280.054 uV, v_off_fin = 281.795 uV 10:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.959 uVs 10:15:17 Integrated Voltage Measurement... 10:15:26 Voltage Offset Correction: v_off_ini = 275.308 uV, v_off_fin = 274.669 uV 10:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.227 uVs 10:15:26 Integrated Voltage Measurement... 10:15:35 Voltage Offset Correction: v_off_ini = 291.513 uV, v_off_fin = 294.978 uV 10:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.236 uVs 10:15:39 I1X Average and RMS of Measurements VT = -52.522 +- 4.708 uVs I1X = 10.504 +- 0.942 uTm 10:15:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:15:46 Integrated Voltage Measurement... 10:15:55 Voltage Offset Correction: v_off_ini = 287.943 uV, v_off_fin = 277.982 uV 10:15:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -193.121 uVs 10:15:55 Integrated Voltage Measurement... 10:16:04 Voltage Offset Correction: v_off_ini = 281.136 uV, v_off_fin = 288.206 uV 10:16:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.326 uVs 10:16:04 Integrated Voltage Measurement... 10:16:13 Voltage Offset Correction: v_off_ini = 287.065 uV, v_off_fin = 277.257 uV 10:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.144 uVs 10:16:13 Integrated Voltage Measurement... 10:16:22 Voltage Offset Correction: v_off_ini = 282.589 uV, v_off_fin = 287.871 uV 10:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.887 uVs 10:16:22 Integrated Voltage Measurement... 10:16:31 Voltage Offset Correction: v_off_ini = 280.095 uV, v_off_fin = 261.421 uV 10:16:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.455 uVs 10:16:31 Integrated Voltage Measurement... 10:16:40 Voltage Offset Correction: v_off_ini = 267.760 uV, v_off_fin = 277.232 uV 10:16:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.296 uVs 10:16:44 I1Y Average and RMS of Measurements VT = -198.371 +- 4.002 uVs I1Y = -39.676 +- 0.798 uTm 10:16:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:16:52 Integrated Voltage Measurement... 10:17:01 Voltage Offset Correction: v_off_ini = 279.706 uV, v_off_fin = 272.761 uV 10:17:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -74.999 uVs 10:17:01 Integrated Voltage Measurement... 10:17:10 Voltage Offset Correction: v_off_ini = 287.886 uV, v_off_fin = 290.081 uV 10:17:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.352 uVs 10:17:10 Integrated Voltage Measurement... 10:17:19 Voltage Offset Correction: v_off_ini = 269.039 uV, v_off_fin = 253.745 uV 10:17:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.464 uVs 10:17:19 Integrated Voltage Measurement... 10:17:28 Voltage Offset Correction: v_off_ini = 274.289 uV, v_off_fin = 280.199 uV 10:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.746 uVs 10:17:28 Integrated Voltage Measurement... 10:17:37 Voltage Offset Correction: v_off_ini = 274.528 uV, v_off_fin = 265.772 uV 10:17:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.958 uVs 10:17:37 Integrated Voltage Measurement... 10:17:46 Voltage Offset Correction: v_off_ini = 272.823 uV, v_off_fin = 291.459 uV 10:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.540 uVs 10:17:48 I2X Average and RMS of Measurements VT = -65.843 +- 2.438 uVs I2X = 6.057 +- 0.224 uTm^2 10:17:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:17:56 Integrated Voltage Measurement... 10:18:05 Voltage Offset Correction: v_off_ini = 268.871 uV, v_off_fin = 276.690 uV 10:18:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.225 uVs 10:18:05 Integrated Voltage Measurement... 10:18:14 Voltage Offset Correction: v_off_ini = 265.120 uV, v_off_fin = 261.884 uV 10:18:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.231 uVs 10:18:14 Integrated Voltage Measurement... 10:18:23 Voltage Offset Correction: v_off_ini = 276.626 uV, v_off_fin = 274.572 uV 10:18:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.068 uVs 10:18:23 Integrated Voltage Measurement... 10:18:32 Voltage Offset Correction: v_off_ini = 271.780 uV, v_off_fin = 267.848 uV 10:18:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.662 uVs 10:18:32 Integrated Voltage Measurement... 10:18:41 Voltage Offset Correction: v_off_ini = 254.950 uV, v_off_fin = 252.284 uV 10:18:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.627 uVs 10:18:41 Integrated Voltage Measurement... 10:18:50 Voltage Offset Correction: v_off_ini = 264.694 uV, v_off_fin = 280.750 uV 10:18:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.077 uVs 10:18:53 I2Y Average and RMS of Measurements VT = -263.815 +- 3.833 uVs I2Y = -24.271 +- 0.353 uTm^2 10:18:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:19:01 Integrated Voltage Measurement... 10:19:10 Voltage Offset Correction: v_off_ini = 278.290 uV, v_off_fin = 259.596 uV 10:19:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.524 uVs 10:19:10 Integrated Voltage Measurement... 10:19:19 Voltage Offset Correction: v_off_ini = 274.431 uV, v_off_fin = 279.936 uV 10:19:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.989 uVs 10:19:19 Integrated Voltage Measurement... 10:19:28 Voltage Offset Correction: v_off_ini = 264.462 uV, v_off_fin = 255.611 uV 10:19:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.934 uVs 10:19:28 Integrated Voltage Measurement... 10:19:37 Voltage Offset Correction: v_off_ini = 265.806 uV, v_off_fin = 266.603 uV 10:19:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.756 uVs 10:19:38 Integrated Voltage Measurement... 10:19:46 Voltage Offset Correction: v_off_ini = 256.336 uV, v_off_fin = 266.155 uV 10:19:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.370 uVs 10:19:47 Integrated Voltage Measurement... 10:19:55 Voltage Offset Correction: v_off_ini = 273.343 uV, v_off_fin = 275.339 uV 10:19:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 17.708 uVs 10:20:00 I1X Average and RMS of Measurements VT = -39.380 +- 7.830 uVs I1X = 7.876 +- 1.566 uTm 10:20:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:20:07 Integrated Voltage Measurement... 10:20:15 Voltage Offset Correction: v_off_ini = 280.819 uV, v_off_fin = 277.933 uV 10:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.112 uVs 10:20:16 Integrated Voltage Measurement... 10:20:24 Voltage Offset Correction: v_off_ini = 282.930 uV, v_off_fin = 288.291 uV 10:20:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 190.313 uVs 10:20:25 Integrated Voltage Measurement... 10:20:33 Voltage Offset Correction: v_off_ini = 281.348 uV, v_off_fin = 280.006 uV 10:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.965 uVs 10:20:33 Integrated Voltage Measurement... 10:20:42 Voltage Offset Correction: v_off_ini = 281.750 uV, v_off_fin = 291.135 uV 10:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.012 uVs 10:20:42 Integrated Voltage Measurement... 10:20:51 Voltage Offset Correction: v_off_ini = 292.270 uV, v_off_fin = 277.017 uV 10:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.596 uVs 10:20:51 Integrated Voltage Measurement... 10:21:00 Voltage Offset Correction: v_off_ini = 297.048 uV, v_off_fin = 298.095 uV 10:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.530 uVs 10:21:05 I1Y Average and RMS of Measurements VT = -199.921 +- 4.346 uVs I1Y = -39.985 +- 0.869 uTm 10:21:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:21:12 Integrated Voltage Measurement... 10:21:21 Voltage Offset Correction: v_off_ini = 291.151 uV, v_off_fin = 285.206 uV 10:21:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.569 uVs 10:21:21 Integrated Voltage Measurement... 10:21:30 Voltage Offset Correction: v_off_ini = 289.822 uV, v_off_fin = 300.444 uV 10:21:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.144 uVs 10:21:30 Integrated Voltage Measurement... 10:21:39 Voltage Offset Correction: v_off_ini = 297.539 uV, v_off_fin = 286.153 uV 10:21:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.980 uVs 10:21:40 Integrated Voltage Measurement... 10:21:48 Voltage Offset Correction: v_off_ini = 294.556 uV, v_off_fin = 314.305 uV 10:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.309 uVs 10:21:49 Integrated Voltage Measurement... 10:21:58 Voltage Offset Correction: v_off_ini = 307.451 uV, v_off_fin = 308.218 uV 10:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.691 uVs 10:21:58 Integrated Voltage Measurement... 10:22:07 Voltage Offset Correction: v_off_ini = 313.200 uV, v_off_fin = 320.059 uV 10:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.449 uVs 10:22:09 I2X Average and RMS of Measurements VT = -62.190 +- 10.192 uVs I2X = 5.722 +- 0.938 uTm^2 10:22:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:22:17 Integrated Voltage Measurement... 10:22:26 Voltage Offset Correction: v_off_ini = 307.367 uV, v_off_fin = 314.949 uV 10:22:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.405 uVs 10:22:26 Integrated Voltage Measurement... 10:22:35 Voltage Offset Correction: v_off_ini = 317.702 uV, v_off_fin = 312.527 uV 10:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.818 uVs 10:22:35 Integrated Voltage Measurement... 10:22:44 Voltage Offset Correction: v_off_ini = 312.428 uV, v_off_fin = 300.165 uV 10:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.139 uVs 10:22:44 Integrated Voltage Measurement... 10:22:53 Voltage Offset Correction: v_off_ini = 293.165 uV, v_off_fin = 309.158 uV 10:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.603 uVs 10:22:53 Integrated Voltage Measurement... 10:23:02 Voltage Offset Correction: v_off_ini = 296.779 uV, v_off_fin = 308.940 uV 10:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.294 uVs 10:23:02 Integrated Voltage Measurement... 10:23:11 Voltage Offset Correction: v_off_ini = 297.664 uV, v_off_fin = 298.434 uV 10:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.951 uVs 10:23:13 I2Y Average and RMS of Measurements VT = -259.868 +- 4.133 uVs I2Y = -23.908 +- 0.380 uTm^2 10:23:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:23:25 Integrated Voltage Measurement... 10:23:34 Voltage Offset Correction: v_off_ini = 310.092 uV, v_off_fin = 302.043 uV 10:23:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.407 uVs 10:23:34 Integrated Voltage Measurement... 10:23:43 Voltage Offset Correction: v_off_ini = 321.583 uV, v_off_fin = 319.241 uV 10:23:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.141 uVs 10:23:43 Integrated Voltage Measurement... 10:23:52 Voltage Offset Correction: v_off_ini = 313.553 uV, v_off_fin = 310.291 uV 10:23:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.682 uVs 10:23:52 Integrated Voltage Measurement... 10:24:01 Voltage Offset Correction: v_off_ini = 316.480 uV, v_off_fin = 327.783 uV 10:24:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.826 uVs 10:24:01 Integrated Voltage Measurement... 10:24:10 Voltage Offset Correction: v_off_ini = 309.279 uV, v_off_fin = 317.458 uV 10:24:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.296 uVs 10:24:10 Integrated Voltage Measurement... 10:24:19 Voltage Offset Correction: v_off_ini = 314.706 uV, v_off_fin = 327.585 uV 10:24:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.055 uVs 10:24:24 I1X Average and RMS of Measurements VT = -38.235 +- 3.550 uVs I1X = 7.647 +- 0.710 uTm 10:24:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:24:30 Integrated Voltage Measurement... 10:24:39 Voltage Offset Correction: v_off_ini = 323.265 uV, v_off_fin = 315.704 uV 10:24:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.891 uVs 10:24:39 Integrated Voltage Measurement... 10:24:48 Voltage Offset Correction: v_off_ini = 304.877 uV, v_off_fin = 321.629 uV 10:24:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.132 uVs 10:24:48 Integrated Voltage Measurement... 10:24:57 Voltage Offset Correction: v_off_ini = 307.184 uV, v_off_fin = 301.862 uV 10:24:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.135 uVs 10:24:57 Integrated Voltage Measurement... 10:25:06 Voltage Offset Correction: v_off_ini = 313.936 uV, v_off_fin = 326.787 uV 10:25:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.316 uVs 10:25:06 Integrated Voltage Measurement... 10:25:15 Voltage Offset Correction: v_off_ini = 319.679 uV, v_off_fin = 313.279 uV 10:25:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.815 uVs 10:25:15 Integrated Voltage Measurement... 10:25:24 Voltage Offset Correction: v_off_ini = 317.261 uV, v_off_fin = 325.382 uV 10:25:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.638 uVs 10:25:29 I1Y Average and RMS of Measurements VT = -208.655 +- 4.037 uVs I1Y = -41.731 +- 0.807 uTm 10:25:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:25:34 Integrated Voltage Measurement... 10:25:43 Voltage Offset Correction: v_off_ini = 307.390 uV, v_off_fin = 314.731 uV 10:25:43 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -40.694 uVs 10:25:43 Integrated Voltage Measurement... 10:25:52 Voltage Offset Correction: v_off_ini = 338.947 uV, v_off_fin = 336.328 uV 10:25:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.654 uVs 10:25:52 Integrated Voltage Measurement... 10:26:01 Voltage Offset Correction: v_off_ini = 322.562 uV, v_off_fin = 319.295 uV 10:26:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.067 uVs 10:26:01 Integrated Voltage Measurement... 10:26:10 Voltage Offset Correction: v_off_ini = 324.236 uV, v_off_fin = 326.084 uV 10:26:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.941 uVs 10:26:10 Integrated Voltage Measurement... 10:26:19 Voltage Offset Correction: v_off_ini = 316.936 uV, v_off_fin = 303.975 uV 10:26:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.922 uVs 10:26:19 Integrated Voltage Measurement... 10:26:28 Voltage Offset Correction: v_off_ini = 317.672 uV, v_off_fin = 327.546 uV 10:26:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.630 uVs 10:26:30 I2X Average and RMS of Measurements VT = -59.652 +- 8.148 uVs I2X = 5.488 +- 0.750 uTm^2 10:26:33 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:26:35 Integrated Voltage Measurement... 10:26:44 Voltage Offset Correction: v_off_ini = 319.290 uV, v_off_fin = 309.032 uV 10:26:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.973 uVs 10:26:44 Integrated Voltage Measurement... 10:26:53 Voltage Offset Correction: v_off_ini = 310.389 uV, v_off_fin = 296.263 uV 10:26:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.856 uVs 10:26:53 Integrated Voltage Measurement... 10:27:02 Voltage Offset Correction: v_off_ini = 301.992 uV, v_off_fin = 306.287 uV 10:27:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.670 uVs 10:27:03 Integrated Voltage Measurement... 10:27:11 Voltage Offset Correction: v_off_ini = 296.265 uV, v_off_fin = 302.761 uV 10:27:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.102 uVs 10:27:12 Integrated Voltage Measurement... 10:27:21 Voltage Offset Correction: v_off_ini = 309.957 uV, v_off_fin = 299.941 uV 10:27:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.139 uVs 10:27:21 Integrated Voltage Measurement... 10:27:30 Voltage Offset Correction: v_off_ini = 305.480 uV, v_off_fin = 289.539 uV 10:27:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.437 uVs 10:27:32 I2Y Average and RMS of Measurements VT = -275.863 +- 1.812 uVs I2Y = -25.379 +- 0.167 uTm^2 10:27:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:27:40 Integrated Voltage Measurement... 10:27:49 Voltage Offset Correction: v_off_ini = 308.594 uV, v_off_fin = 289.318 uV 10:27:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.679 uVs 10:27:49 Integrated Voltage Measurement... 10:27:58 Voltage Offset Correction: v_off_ini = 290.870 uV, v_off_fin = 297.112 uV 10:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.826 uVs 10:27:58 Integrated Voltage Measurement... 10:28:07 Voltage Offset Correction: v_off_ini = 303.473 uV, v_off_fin = 299.941 uV 10:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.313 uVs 10:28:07 Integrated Voltage Measurement... 10:28:16 Voltage Offset Correction: v_off_ini = 293.506 uV, v_off_fin = 290.299 uV 10:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.429 uVs 10:28:16 Integrated Voltage Measurement... 10:28:25 Voltage Offset Correction: v_off_ini = 289.839 uV, v_off_fin = 293.167 uV 10:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.462 uVs 10:28:25 Integrated Voltage Measurement... 10:28:34 Voltage Offset Correction: v_off_ini = 286.201 uV, v_off_fin = 304.811 uV 10:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.203 uVs 10:28:39 I1X Average and RMS of Measurements VT = -55.485 +- 3.251 uVs I1X = 11.097 +- 0.650 uTm 10:28:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:28:45 Integrated Voltage Measurement... 10:28:54 Voltage Offset Correction: v_off_ini = 289.984 uV, v_off_fin = 281.102 uV 10:28:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -207.684 uVs 10:28:54 Integrated Voltage Measurement... 10:29:03 Voltage Offset Correction: v_off_ini = 299.022 uV, v_off_fin = 307.559 uV 10:29:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.231 uVs 10:29:03 Integrated Voltage Measurement... 10:29:12 Voltage Offset Correction: v_off_ini = 288.692 uV, v_off_fin = 278.338 uV 10:29:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.373 uVs 10:29:12 Integrated Voltage Measurement... 10:29:21 Voltage Offset Correction: v_off_ini = 285.582 uV, v_off_fin = 292.000 uV 10:29:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.244 uVs 10:29:21 Integrated Voltage Measurement... 10:29:30 Voltage Offset Correction: v_off_ini = 286.326 uV, v_off_fin = 281.199 uV 10:29:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.145 uVs 10:29:30 Integrated Voltage Measurement... 10:29:39 Voltage Offset Correction: v_off_ini = 283.189 uV, v_off_fin = 297.179 uV 10:29:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.565 uVs 10:29:44 I1Y Average and RMS of Measurements VT = -203.040 +- 1.645 uVs I1Y = -40.609 +- 0.328 uTm 10:29:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:29:49 Integrated Voltage Measurement... 10:29:58 Voltage Offset Correction: v_off_ini = 300.358 uV, v_off_fin = 289.279 uV 10:29:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.153 uVs 10:29:58 Integrated Voltage Measurement... 10:30:07 Voltage Offset Correction: v_off_ini = 306.697 uV, v_off_fin = 317.432 uV 10:30:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.366 uVs 10:30:07 Integrated Voltage Measurement... 10:30:16 Voltage Offset Correction: v_off_ini = 305.083 uV, v_off_fin = 293.521 uV 10:30:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.036 uVs 10:30:16 Integrated Voltage Measurement... 10:30:25 Voltage Offset Correction: v_off_ini = 295.114 uV, v_off_fin = 299.141 uV 10:30:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.082 uVs 10:30:25 Integrated Voltage Measurement... 10:30:34 Voltage Offset Correction: v_off_ini = 283.633 uV, v_off_fin = 288.187 uV 10:30:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.467 uVs 10:30:34 Integrated Voltage Measurement... 10:30:43 Voltage Offset Correction: v_off_ini = 289.215 uV, v_off_fin = 306.749 uV 10:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.679 uVs 10:30:45 I2X Average and RMS of Measurements VT = -74.630 +- 4.220 uVs I2X = 6.866 +- 0.388 uTm^2 10:30:48 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:30:50 Integrated Voltage Measurement... 10:30:59 Voltage Offset Correction: v_off_ini = 271.712 uV, v_off_fin = 276.150 uV 10:30:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.903 uVs 10:30:59 Integrated Voltage Measurement... 10:31:08 Voltage Offset Correction: v_off_ini = 281.299 uV, v_off_fin = 270.704 uV 10:31:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.570 uVs 10:31:08 Integrated Voltage Measurement... 10:31:17 Voltage Offset Correction: v_off_ini = 274.895 uV, v_off_fin = 291.432 uV 10:31:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.840 uVs 10:31:18 Integrated Voltage Measurement... 10:31:26 Voltage Offset Correction: v_off_ini = 289.084 uV, v_off_fin = 268.573 uV 10:31:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.050 uVs 10:31:27 Integrated Voltage Measurement... 10:31:36 Voltage Offset Correction: v_off_ini = 277.078 uV, v_off_fin = 270.419 uV 10:31:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.095 uVs 10:31:36 Integrated Voltage Measurement... 10:31:45 Voltage Offset Correction: v_off_ini = 260.592 uV, v_off_fin = 269.910 uV 10:31:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.009 uVs 10:31:47 I2Y Average and RMS of Measurements VT = -266.745 +- 13.558 uVs I2Y = -24.540 +- 1.247 uTm^2 10:31:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:31:55 Integrated Voltage Measurement... 10:32:04 Voltage Offset Correction: v_off_ini = 269.201 uV, v_off_fin = 262.337 uV 10:32:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.449 uVs 10:32:04 Integrated Voltage Measurement... 10:32:13 Voltage Offset Correction: v_off_ini = 267.246 uV, v_off_fin = 271.970 uV 10:32:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.216 uVs 10:32:13 Integrated Voltage Measurement... 10:32:22 Voltage Offset Correction: v_off_ini = 277.774 uV, v_off_fin = 257.354 uV 10:32:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -52.110 uVs 10:32:22 Integrated Voltage Measurement... 10:32:31 Voltage Offset Correction: v_off_ini = 272.421 uV, v_off_fin = 283.392 uV 10:32:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.040 uVs 10:32:31 Integrated Voltage Measurement... 10:32:40 Voltage Offset Correction: v_off_ini = 286.892 uV, v_off_fin = 274.409 uV 10:32:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.547 uVs 10:32:40 Integrated Voltage Measurement... 10:32:49 Voltage Offset Correction: v_off_ini = 287.176 uV, v_off_fin = 278.086 uV 10:32:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.054 uVs 10:32:54 I1X Average and RMS of Measurements VT = -68.569 +- 15.751 uVs I1X = 13.714 +- 3.150 uTm 10:32:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:33:00 Integrated Voltage Measurement... 10:33:09 Voltage Offset Correction: v_off_ini = 283.564 uV, v_off_fin = 270.405 uV 10:33:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.042 uVs 10:33:09 Integrated Voltage Measurement... 10:33:18 Voltage Offset Correction: v_off_ini = 278.088 uV, v_off_fin = 302.077 uV 10:33:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.179 uVs 10:33:18 Integrated Voltage Measurement... 10:33:27 Voltage Offset Correction: v_off_ini = 290.551 uV, v_off_fin = 279.815 uV 10:33:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.988 uVs 10:33:27 Integrated Voltage Measurement... 10:33:36 Voltage Offset Correction: v_off_ini = 271.304 uV, v_off_fin = 274.227 uV 10:33:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.267 uVs 10:33:36 Integrated Voltage Measurement... 10:33:45 Voltage Offset Correction: v_off_ini = 266.439 uV, v_off_fin = 264.895 uV 10:33:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.746 uVs 10:33:45 Integrated Voltage Measurement... 10:33:54 Voltage Offset Correction: v_off_ini = 291.224 uV, v_off_fin = 293.333 uV 10:33:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.447 uVs 10:33:59 I1Y Average and RMS of Measurements VT = -193.612 +- 3.547 uVs I1Y = -38.722 +- 0.709 uTm 10:34:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:34:04 Integrated Voltage Measurement... 10:34:13 Voltage Offset Correction: v_off_ini = 289.246 uV, v_off_fin = 275.621 uV 10:34:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.043 uVs 10:34:13 Integrated Voltage Measurement... 10:34:22 Voltage Offset Correction: v_off_ini = 285.543 uV, v_off_fin = 296.053 uV 10:34:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.056 uVs 10:34:22 Integrated Voltage Measurement... 10:34:31 Voltage Offset Correction: v_off_ini = 283.680 uV, v_off_fin = 277.436 uV 10:34:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.521 uVs 10:34:31 Integrated Voltage Measurement... 10:34:40 Voltage Offset Correction: v_off_ini = 274.038 uV, v_off_fin = 287.666 uV 10:34:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.178 uVs 10:34:40 Integrated Voltage Measurement... 10:34:49 Voltage Offset Correction: v_off_ini = 280.677 uV, v_off_fin = 259.293 uV 10:34:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.879 uVs 10:34:49 Integrated Voltage Measurement... 10:34:58 Voltage Offset Correction: v_off_ini = 259.157 uV, v_off_fin = 265.066 uV 10:34:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.842 uVs 10:35:00 I2X Average and RMS of Measurements VT = -86.420 +- 1.466 uVs I2X = 7.951 +- 0.135 uTm^2 10:35:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:35:05 Integrated Voltage Measurement... 10:35:14 Voltage Offset Correction: v_off_ini = 267.967 uV, v_off_fin = 260.938 uV 10:35:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.850 uVs 10:35:14 Integrated Voltage Measurement... 10:35:23 Voltage Offset Correction: v_off_ini = 259.584 uV, v_off_fin = 254.507 uV 10:35:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.455 uVs 10:35:24 Integrated Voltage Measurement... 10:35:32 Voltage Offset Correction: v_off_ini = 269.179 uV, v_off_fin = 257.690 uV 10:35:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.590 uVs 10:35:33 Integrated Voltage Measurement... 10:35:42 Voltage Offset Correction: v_off_ini = 270.869 uV, v_off_fin = 257.592 uV 10:35:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.150 uVs 10:35:42 Integrated Voltage Measurement... 10:35:51 Voltage Offset Correction: v_off_ini = 262.064 uV, v_off_fin = 261.407 uV 10:35:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.897 uVs 10:35:51 Integrated Voltage Measurement... 10:36:00 Voltage Offset Correction: v_off_ini = 266.473 uV, v_off_fin = 255.731 uV 10:36:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.740 uVs 10:36:02 I2Y Average and RMS of Measurements VT = -268.947 +- 3.486 uVs I2Y = -24.743 +- 0.321 uTm^2 10:36:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:36:10 Integrated Voltage Measurement... 10:36:19 Voltage Offset Correction: v_off_ini = 231.100 uV, v_off_fin = 236.203 uV 10:36:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -35.161 uVs 10:36:19 Integrated Voltage Measurement... 10:36:28 Voltage Offset Correction: v_off_ini = 245.310 uV, v_off_fin = 257.059 uV 10:36:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.677 uVs 10:36:28 Integrated Voltage Measurement... 10:36:37 Voltage Offset Correction: v_off_ini = 250.556 uV, v_off_fin = 236.885 uV 10:36:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.817 uVs 10:36:37 Integrated Voltage Measurement... 10:36:46 Voltage Offset Correction: v_off_ini = 245.034 uV, v_off_fin = 257.877 uV 10:36:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.276 uVs 10:36:46 Integrated Voltage Measurement... 10:36:55 Voltage Offset Correction: v_off_ini = 243.967 uV, v_off_fin = 246.262 uV 10:36:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.363 uVs 10:36:56 Integrated Voltage Measurement... 10:37:04 Voltage Offset Correction: v_off_ini = 243.666 uV, v_off_fin = 244.937 uV 10:37:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.877 uVs 10:37:09 I1X Average and RMS of Measurements VT = -48.695 +- 12.119 uVs I1X = 9.740 +- 2.424 uTm 10:37:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:37:15 Integrated Voltage Measurement... 10:37:24 Voltage Offset Correction: v_off_ini = 249.743 uV, v_off_fin = 238.230 uV 10:37:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.790 uVs 10:37:24 Integrated Voltage Measurement... 10:37:33 Voltage Offset Correction: v_off_ini = 244.000 uV, v_off_fin = 257.563 uV 10:37:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.870 uVs 10:37:33 Integrated Voltage Measurement... 10:37:42 Voltage Offset Correction: v_off_ini = 249.960 uV, v_off_fin = 236.619 uV 10:37:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.338 uVs 10:37:42 Integrated Voltage Measurement... 10:37:51 Voltage Offset Correction: v_off_ini = 251.835 uV, v_off_fin = 245.223 uV 10:37:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.042 uVs 10:37:51 Integrated Voltage Measurement... 10:38:00 Voltage Offset Correction: v_off_ini = 240.880 uV, v_off_fin = 220.779 uV 10:38:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.393 uVs 10:38:00 Integrated Voltage Measurement... 10:38:09 Voltage Offset Correction: v_off_ini = 232.851 uV, v_off_fin = 253.697 uV 10:38:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.059 uVs 10:38:14 I1Y Average and RMS of Measurements VT = -189.082 +- 2.982 uVs I1Y = -37.816 +- 0.596 uTm 10:38:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:38:19 Integrated Voltage Measurement... 10:38:28 Voltage Offset Correction: v_off_ini = 224.809 uV, v_off_fin = 229.884 uV 10:38:28 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.758 uVs 10:38:28 Integrated Voltage Measurement... 10:38:37 Voltage Offset Correction: v_off_ini = 229.927 uV, v_off_fin = 236.643 uV 10:38:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.527 uVs 10:38:37 Integrated Voltage Measurement... 10:38:46 Voltage Offset Correction: v_off_ini = 240.489 uV, v_off_fin = 225.253 uV 10:38:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.600 uVs 10:38:46 Integrated Voltage Measurement... 10:38:55 Voltage Offset Correction: v_off_ini = 229.052 uV, v_off_fin = 227.171 uV 10:38:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.056 uVs 10:38:55 Integrated Voltage Measurement... 10:39:04 Voltage Offset Correction: v_off_ini = 226.037 uV, v_off_fin = 216.134 uV 10:39:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.472 uVs 10:39:04 Integrated Voltage Measurement... 10:39:13 Voltage Offset Correction: v_off_ini = 223.303 uV, v_off_fin = 235.553 uV 10:39:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.158 uVs 10:39:15 I2X Average and RMS of Measurements VT = -88.429 +- 4.322 uVs I2X = 8.135 +- 0.398 uTm^2 10:39:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:39:20 Integrated Voltage Measurement... 10:39:29 Voltage Offset Correction: v_off_ini = 213.477 uV, v_off_fin = 222.872 uV 10:39:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.817 uVs 10:39:29 Integrated Voltage Measurement... 10:39:38 Voltage Offset Correction: v_off_ini = 218.872 uV, v_off_fin = 226.530 uV 10:39:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.548 uVs 10:39:39 Integrated Voltage Measurement... 10:39:48 Voltage Offset Correction: v_off_ini = 231.794 uV, v_off_fin = 227.540 uV 10:39:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.614 uVs 10:39:48 Integrated Voltage Measurement... 10:39:57 Voltage Offset Correction: v_off_ini = 233.822 uV, v_off_fin = 233.774 uV 10:39:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.878 uVs 10:39:57 Integrated Voltage Measurement... 10:40:06 Voltage Offset Correction: v_off_ini = 236.945 uV, v_off_fin = 229.987 uV 10:40:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.701 uVs 10:40:06 Integrated Voltage Measurement... 10:40:15 Voltage Offset Correction: v_off_ini = 239.834 uV, v_off_fin = 239.190 uV 10:40:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.261 uVs 10:40:17 I2Y Average and RMS of Measurements VT = -250.303 +- 1.760 uVs I2Y = -23.028 +- 0.162 uTm^2 10:40:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:40:25 Integrated Voltage Measurement... 10:40:34 Voltage Offset Correction: v_off_ini = 250.696 uV, v_off_fin = 227.099 uV 10:40:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.975 uVs 10:40:34 Integrated Voltage Measurement... 10:40:43 Voltage Offset Correction: v_off_ini = 233.018 uV, v_off_fin = 248.393 uV 10:40:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.714 uVs 10:40:43 Integrated Voltage Measurement... 10:40:52 Voltage Offset Correction: v_off_ini = 233.077 uV, v_off_fin = 225.261 uV 10:40:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.911 uVs 10:40:52 Integrated Voltage Measurement... 10:41:01 Voltage Offset Correction: v_off_ini = 241.790 uV, v_off_fin = 246.891 uV 10:41:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.742 uVs 10:41:02 Integrated Voltage Measurement... 10:41:10 Voltage Offset Correction: v_off_ini = 240.365 uV, v_off_fin = 241.974 uV 10:41:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.160 uVs 10:41:11 Integrated Voltage Measurement... 10:41:19 Voltage Offset Correction: v_off_ini = 243.908 uV, v_off_fin = 239.507 uV 10:41:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.770 uVs 10:41:24 I1X Average and RMS of Measurements VT = -44.378 +- 4.654 uVs I1X = 8.876 +- 0.931 uTm 10:41:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:41:31 Integrated Voltage Measurement... 10:41:39 Voltage Offset Correction: v_off_ini = 233.525 uV, v_off_fin = 235.800 uV 10:41:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.649 uVs 10:41:40 Integrated Voltage Measurement... 10:41:48 Voltage Offset Correction: v_off_ini = 237.549 uV, v_off_fin = 254.602 uV 10:41:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.591 uVs 10:41:49 Integrated Voltage Measurement... 10:41:57 Voltage Offset Correction: v_off_ini = 259.206 uV, v_off_fin = 245.433 uV 10:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.139 uVs 10:41:58 Integrated Voltage Measurement... 10:42:06 Voltage Offset Correction: v_off_ini = 237.252 uV, v_off_fin = 238.381 uV 10:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.342 uVs 10:42:07 Integrated Voltage Measurement... 10:42:15 Voltage Offset Correction: v_off_ini = 243.327 uV, v_off_fin = 227.413 uV 10:42:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.943 uVs 10:42:16 Integrated Voltage Measurement... 10:42:24 Voltage Offset Correction: v_off_ini = 240.896 uV, v_off_fin = 251.480 uV 10:42:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.689 uVs 10:42:29 I1Y Average and RMS of Measurements VT = -182.892 +- 4.650 uVs I1Y = -36.578 +- 0.930 uTm 10:42:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:42:34 Integrated Voltage Measurement... 10:42:43 Voltage Offset Correction: v_off_ini = 252.563 uV, v_off_fin = 240.987 uV 10:42:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.329 uVs 10:42:43 Integrated Voltage Measurement... 10:42:52 Voltage Offset Correction: v_off_ini = 251.350 uV, v_off_fin = 261.322 uV 10:42:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.049 uVs 10:42:52 Integrated Voltage Measurement... 10:43:01 Voltage Offset Correction: v_off_ini = 245.966 uV, v_off_fin = 235.572 uV 10:43:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.809 uVs 10:43:01 Integrated Voltage Measurement... 10:43:10 Voltage Offset Correction: v_off_ini = 246.316 uV, v_off_fin = 262.727 uV 10:43:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.794 uVs 10:43:10 Integrated Voltage Measurement... 10:43:19 Voltage Offset Correction: v_off_ini = 251.030 uV, v_off_fin = 238.491 uV 10:43:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -73.724 uVs 10:43:19 Integrated Voltage Measurement... 10:43:28 Voltage Offset Correction: v_off_ini = 242.425 uV, v_off_fin = 256.014 uV 10:43:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.313 uVs 10:43:30 I2X Average and RMS of Measurements VT = -73.836 +- 8.935 uVs I2X = 6.793 +- 0.822 uTm^2 10:43:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:43:36 Integrated Voltage Measurement... 10:43:45 Voltage Offset Correction: v_off_ini = 244.424 uV, v_off_fin = 252.806 uV 10:43:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.882 uVs 10:43:45 Integrated Voltage Measurement... 10:43:54 Voltage Offset Correction: v_off_ini = 261.610 uV, v_off_fin = 258.447 uV 10:43:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.041 uVs 10:43:54 Integrated Voltage Measurement... 10:44:03 Voltage Offset Correction: v_off_ini = 261.420 uV, v_off_fin = 265.066 uV 10:44:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.218 uVs 10:44:03 Integrated Voltage Measurement... 10:44:12 Voltage Offset Correction: v_off_ini = 256.610 uV, v_off_fin = 264.772 uV 10:44:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.844 uVs 10:44:12 Integrated Voltage Measurement... 10:44:21 Voltage Offset Correction: v_off_ini = 275.123 uV, v_off_fin = 273.333 uV 10:44:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.908 uVs 10:44:21 Integrated Voltage Measurement... 10:44:30 Voltage Offset Correction: v_off_ini = 258.402 uV, v_off_fin = 274.856 uV 10:44:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.138 uVs 10:44:32 I2Y Average and RMS of Measurements VT = -250.005 +- 4.950 uVs I2Y = -23.000 +- 0.455 uTm^2 10:44:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:44:53 Integrated Voltage Measurement... 10:45:02 Voltage Offset Correction: v_off_ini = 284.089 uV, v_off_fin = 268.674 uV 10:45:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -100.426 uVs 10:45:03 Integrated Voltage Measurement... 10:45:11 Voltage Offset Correction: v_off_ini = 290.402 uV, v_off_fin = 277.702 uV 10:45:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.079 uVs 10:45:12 Integrated Voltage Measurement... 10:45:20 Voltage Offset Correction: v_off_ini = 283.744 uV, v_off_fin = 283.736 uV 10:45:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.834 uVs 10:45:21 Integrated Voltage Measurement... 10:45:30 Voltage Offset Correction: v_off_ini = 301.448 uV, v_off_fin = 305.879 uV 10:45:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.416 uVs 10:45:30 Integrated Voltage Measurement... 10:45:39 Voltage Offset Correction: v_off_ini = 299.779 uV, v_off_fin = 277.327 uV 10:45:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.424 uVs 10:45:39 Integrated Voltage Measurement... 10:45:48 Voltage Offset Correction: v_off_ini = 282.203 uV, v_off_fin = 277.421 uV 10:45:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.594 uVs 10:45:52 I1X Average and RMS of Measurements VT = -78.462 +- 8.739 uVs I1X = 15.693 +- 1.749 uTm 10:45:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:45:59 Integrated Voltage Measurement... 10:46:08 Voltage Offset Correction: v_off_ini = 281.463 uV, v_off_fin = 274.295 uV 10:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.644 uVs 10:46:08 Integrated Voltage Measurement... 10:46:17 Voltage Offset Correction: v_off_ini = 268.240 uV, v_off_fin = 284.881 uV 10:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.426 uVs 10:46:17 Integrated Voltage Measurement... 10:46:26 Voltage Offset Correction: v_off_ini = 276.874 uV, v_off_fin = 273.196 uV 10:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.769 uVs 10:46:26 Integrated Voltage Measurement... 10:46:35 Voltage Offset Correction: v_off_ini = 284.708 uV, v_off_fin = 296.961 uV 10:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.830 uVs 10:46:35 Integrated Voltage Measurement... 10:46:44 Voltage Offset Correction: v_off_ini = 285.625 uV, v_off_fin = 280.135 uV 10:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.118 uVs 10:46:44 Integrated Voltage Measurement... 10:46:53 Voltage Offset Correction: v_off_ini = 270.928 uV, v_off_fin = 285.082 uV 10:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.958 uVs 10:46:57 I1Y Average and RMS of Measurements VT = -234.124 +- 2.297 uVs I1Y = -46.825 +- 0.459 uTm 10:47:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:47:04 Integrated Voltage Measurement... 10:47:13 Voltage Offset Correction: v_off_ini = 282.778 uV, v_off_fin = 271.368 uV 10:47:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.829 uVs 10:47:14 Integrated Voltage Measurement... 10:47:23 Voltage Offset Correction: v_off_ini = 280.411 uV, v_off_fin = 298.625 uV 10:47:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.438 uVs 10:47:23 Integrated Voltage Measurement... 10:47:32 Voltage Offset Correction: v_off_ini = 291.123 uV, v_off_fin = 284.310 uV 10:47:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.652 uVs 10:47:32 Integrated Voltage Measurement... 10:47:41 Voltage Offset Correction: v_off_ini = 275.477 uV, v_off_fin = 293.389 uV 10:47:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.787 uVs 10:47:41 Integrated Voltage Measurement... 10:47:50 Voltage Offset Correction: v_off_ini = 288.717 uV, v_off_fin = 271.334 uV 10:47:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.745 uVs 10:47:50 Integrated Voltage Measurement... 10:47:59 Voltage Offset Correction: v_off_ini = 297.759 uV, v_off_fin = 311.107 uV 10:47:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.140 uVs 10:48:01 I2X Average and RMS of Measurements VT = -103.265 +- 7.481 uVs I2X = 9.501 +- 0.688 uTm^2 10:48:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:48:09 Integrated Voltage Measurement... 10:48:18 Voltage Offset Correction: v_off_ini = 284.779 uV, v_off_fin = 278.390 uV 10:48:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.548 uVs 10:48:18 Integrated Voltage Measurement... 10:48:27 Voltage Offset Correction: v_off_ini = 269.786 uV, v_off_fin = 272.418 uV 10:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.779 uVs 10:48:27 Integrated Voltage Measurement... 10:48:36 Voltage Offset Correction: v_off_ini = 265.549 uV, v_off_fin = 267.397 uV 10:48:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.178 uVs 10:48:36 Integrated Voltage Measurement... 10:48:45 Voltage Offset Correction: v_off_ini = 279.210 uV, v_off_fin = 276.532 uV 10:48:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.088 uVs 10:48:45 Integrated Voltage Measurement... 10:48:54 Voltage Offset Correction: v_off_ini = 280.882 uV, v_off_fin = 287.431 uV 10:48:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.655 uVs 10:48:54 Integrated Voltage Measurement... 10:49:03 Voltage Offset Correction: v_off_ini = 288.656 uV, v_off_fin = 279.331 uV 10:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.855 uVs 10:49:05 I2Y Average and RMS of Measurements VT = -297.517 +- 6.158 uVs I2Y = -27.372 +- 0.567 uTm^2 10:49:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:49:14 Integrated Voltage Measurement... 10:49:23 Voltage Offset Correction: v_off_ini = 283.620 uV, v_off_fin = 267.728 uV 10:49:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.942 uVs 10:49:23 Integrated Voltage Measurement... 10:49:32 Voltage Offset Correction: v_off_ini = 261.936 uV, v_off_fin = 269.502 uV 10:49:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.916 uVs 10:49:32 Integrated Voltage Measurement... 10:49:41 Voltage Offset Correction: v_off_ini = 256.619 uV, v_off_fin = 266.152 uV 10:49:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.757 uVs 10:49:42 Integrated Voltage Measurement... 10:49:50 Voltage Offset Correction: v_off_ini = 273.967 uV, v_off_fin = 268.809 uV 10:49:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.661 uVs 10:49:51 Integrated Voltage Measurement... 10:49:59 Voltage Offset Correction: v_off_ini = 271.459 uV, v_off_fin = 270.215 uV 10:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.758 uVs 10:50:00 Integrated Voltage Measurement... 10:50:08 Voltage Offset Correction: v_off_ini = 277.105 uV, v_off_fin = 281.682 uV 10:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.513 uVs 10:50:13 I1X Average and RMS of Measurements VT = -68.591 +- 5.148 uVs I1X = 13.719 +- 1.030 uTm 10:50:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:50:19 Integrated Voltage Measurement... 10:50:28 Voltage Offset Correction: v_off_ini = 260.913 uV, v_off_fin = 257.895 uV 10:50:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.633 uVs 10:50:28 Integrated Voltage Measurement... 10:50:37 Voltage Offset Correction: v_off_ini = 259.374 uV, v_off_fin = 280.201 uV 10:50:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.745 uVs 10:50:37 Integrated Voltage Measurement... 10:50:46 Voltage Offset Correction: v_off_ini = 275.558 uV, v_off_fin = 253.814 uV 10:50:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.289 uVs 10:50:46 Integrated Voltage Measurement... 10:50:55 Voltage Offset Correction: v_off_ini = 274.306 uV, v_off_fin = 281.488 uV 10:50:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.091 uVs 10:50:55 Integrated Voltage Measurement... 10:51:04 Voltage Offset Correction: v_off_ini = 264.240 uV, v_off_fin = 258.968 uV 10:51:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.750 uVs 10:51:04 Integrated Voltage Measurement... 10:51:13 Voltage Offset Correction: v_off_ini = 269.135 uV, v_off_fin = 280.153 uV 10:51:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.437 uVs 10:51:18 I1Y Average and RMS of Measurements VT = -236.991 +- 4.151 uVs I1Y = -47.398 +- 0.830 uTm 10:51:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:51:25 Integrated Voltage Measurement... 10:51:34 Voltage Offset Correction: v_off_ini = 233.893 uV, v_off_fin = 222.180 uV 10:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.463 uVs 10:51:34 Integrated Voltage Measurement... 10:51:43 Voltage Offset Correction: v_off_ini = 214.060 uV, v_off_fin = 237.776 uV 10:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.601 uVs 10:51:43 Integrated Voltage Measurement... 10:51:52 Voltage Offset Correction: v_off_ini = 218.514 uV, v_off_fin = 217.634 uV 10:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.522 uVs 10:51:53 Integrated Voltage Measurement... 10:52:01 Voltage Offset Correction: v_off_ini = 238.603 uV, v_off_fin = 239.940 uV 10:52:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.080 uVs 10:52:02 Integrated Voltage Measurement... 10:52:11 Voltage Offset Correction: v_off_ini = 231.577 uV, v_off_fin = 219.061 uV 10:52:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.264 uVs 10:52:11 Integrated Voltage Measurement... 10:52:20 Voltage Offset Correction: v_off_ini = 221.620 uV, v_off_fin = 243.351 uV 10:52:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.574 uVs 10:52:22 I2X Average and RMS of Measurements VT = -90.251 +- 4.741 uVs I2X = 8.303 +- 0.436 uTm^2 10:52:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:52:30 Integrated Voltage Measurement... 10:52:39 Voltage Offset Correction: v_off_ini = 235.315 uV, v_off_fin = 243.251 uV 10:52:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.600 uVs 10:52:39 Integrated Voltage Measurement... 10:52:48 Voltage Offset Correction: v_off_ini = 249.838 uV, v_off_fin = 235.022 uV 10:52:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.477 uVs 10:52:48 Integrated Voltage Measurement... 10:52:57 Voltage Offset Correction: v_off_ini = 217.412 uV, v_off_fin = 220.290 uV 10:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.104 uVs 10:52:57 Integrated Voltage Measurement... 10:53:06 Voltage Offset Correction: v_off_ini = 219.034 uV, v_off_fin = 212.584 uV 10:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.698 uVs 10:53:06 Integrated Voltage Measurement... 10:53:15 Voltage Offset Correction: v_off_ini = 223.841 uV, v_off_fin = 218.354 uV 10:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.748 uVs 10:53:15 Integrated Voltage Measurement... 10:53:24 Voltage Offset Correction: v_off_ini = 212.241 uV, v_off_fin = 213.690 uV 10:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.914 uVs 10:53:26 I2Y Average and RMS of Measurements VT = -294.257 +- 7.927 uVs I2Y = -27.072 +- 0.729 uTm^2 10:53:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:35 Integrated Voltage Measurement... 10:53:44 Voltage Offset Correction: v_off_ini = 225.538 uV, v_off_fin = 205.936 uV 10:53:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.824 uVs 10:53:44 Integrated Voltage Measurement... 10:53:53 Voltage Offset Correction: v_off_ini = 221.393 uV, v_off_fin = 223.172 uV 10:53:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.300 uVs 10:53:53 Integrated Voltage Measurement... 10:54:02 Voltage Offset Correction: v_off_ini = 217.841 uV, v_off_fin = 202.891 uV 10:54:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.868 uVs 10:54:02 Integrated Voltage Measurement... 10:54:11 Voltage Offset Correction: v_off_ini = 210.257 uV, v_off_fin = 211.250 uV 10:54:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.557 uVs 10:54:11 Integrated Voltage Measurement... 10:54:20 Voltage Offset Correction: v_off_ini = 210.576 uV, v_off_fin = 204.948 uV 10:54:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.485 uVs 10:54:20 Integrated Voltage Measurement... 10:54:29 Voltage Offset Correction: v_off_ini = 209.409 uV, v_off_fin = 210.262 uV 10:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.143 uVs 10:54:34 I1X Average and RMS of Measurements VT = -71.029 +- 8.492 uVs I1X = 14.206 +- 1.698 uTm 10:54:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:54:40 Integrated Voltage Measurement... 10:54:49 Voltage Offset Correction: v_off_ini = 222.519 uV, v_off_fin = 208.325 uV 10:54:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.521 uVs 10:54:49 Integrated Voltage Measurement... 10:54:58 Voltage Offset Correction: v_off_ini = 207.630 uV, v_off_fin = 221.764 uV 10:54:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.701 uVs 10:54:58 Integrated Voltage Measurement... 10:55:07 Voltage Offset Correction: v_off_ini = 214.190 uV, v_off_fin = 206.678 uV 10:55:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.053 uVs 10:55:07 Integrated Voltage Measurement... 10:55:16 Voltage Offset Correction: v_off_ini = 212.037 uV, v_off_fin = 232.811 uV 10:55:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.415 uVs 10:55:16 Integrated Voltage Measurement... 10:55:25 Voltage Offset Correction: v_off_ini = 208.218 uV, v_off_fin = 212.850 uV 10:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.607 uVs 10:55:25 Integrated Voltage Measurement... 10:55:34 Voltage Offset Correction: v_off_ini = 230.623 uV, v_off_fin = 230.524 uV 10:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.067 uVs 10:55:39 I1Y Average and RMS of Measurements VT = -229.727 +- 7.475 uVs I1Y = -45.945 +- 1.495 uTm 10:55:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:55:46 Integrated Voltage Measurement... 10:55:55 Voltage Offset Correction: v_off_ini = 228.152 uV, v_off_fin = 210.972 uV 10:55:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.612 uVs 10:55:55 Integrated Voltage Measurement... 10:56:04 Voltage Offset Correction: v_off_ini = 219.878 uV, v_off_fin = 215.704 uV 10:56:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.752 uVs 10:56:04 Integrated Voltage Measurement... 10:56:13 Voltage Offset Correction: v_off_ini = 205.947 uV, v_off_fin = 215.557 uV 10:56:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.638 uVs 10:56:13 Integrated Voltage Measurement... 10:56:22 Voltage Offset Correction: v_off_ini = 217.943 uV, v_off_fin = 222.641 uV 10:56:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.662 uVs 10:56:23 Integrated Voltage Measurement... 10:56:31 Voltage Offset Correction: v_off_ini = 217.260 uV, v_off_fin = 216.745 uV 10:56:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.340 uVs 10:56:32 Integrated Voltage Measurement... 10:56:40 Voltage Offset Correction: v_off_ini = 218.087 uV, v_off_fin = 243.028 uV 10:56:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.471 uVs 10:56:43 I2X Average and RMS of Measurements VT = -85.246 +- 6.496 uVs I2X = 7.843 +- 0.598 uTm^2 10:56:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:51 Integrated Voltage Measurement... 10:57:00 Voltage Offset Correction: v_off_ini = 220.319 uV, v_off_fin = 236.583 uV 10:57:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.711 uVs 10:57:00 Integrated Voltage Measurement... 10:57:09 Voltage Offset Correction: v_off_ini = 243.473 uV, v_off_fin = 240.567 uV 10:57:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.767 uVs 10:57:09 Integrated Voltage Measurement... 10:57:18 Voltage Offset Correction: v_off_ini = 237.429 uV, v_off_fin = 221.020 uV 10:57:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.529 uVs 10:57:18 Integrated Voltage Measurement... 10:57:27 Voltage Offset Correction: v_off_ini = 207.657 uV, v_off_fin = 213.366 uV 10:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.114 uVs 10:57:27 Integrated Voltage Measurement... 10:57:36 Voltage Offset Correction: v_off_ini = 213.930 uV, v_off_fin = 216.274 uV 10:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.210 uVs 10:57:36 Integrated Voltage Measurement... 10:57:45 Voltage Offset Correction: v_off_ini = 213.573 uV, v_off_fin = 229.407 uV 10:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.967 uVs 10:57:47 I2Y Average and RMS of Measurements VT = -289.883 +- 3.539 uVs I2Y = -26.669 +- 0.326 uTm^2 10:57:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:57:56 Integrated Voltage Measurement... 10:58:05 Voltage Offset Correction: v_off_ini = 217.799 uV, v_off_fin = 207.936 uV 10:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.489 uVs 10:58:05 Integrated Voltage Measurement... 10:58:14 Voltage Offset Correction: v_off_ini = 201.789 uV, v_off_fin = 210.124 uV 10:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.435 uVs 10:58:14 Integrated Voltage Measurement... 10:58:23 Voltage Offset Correction: v_off_ini = 193.787 uV, v_off_fin = 189.791 uV 10:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.388 uVs 10:58:23 Integrated Voltage Measurement... 10:58:32 Voltage Offset Correction: v_off_ini = 200.825 uV, v_off_fin = 210.041 uV 10:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.821 uVs 10:58:32 Integrated Voltage Measurement... 10:58:41 Voltage Offset Correction: v_off_ini = 214.159 uV, v_off_fin = 207.718 uV 10:58:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.631 uVs 10:58:41 Integrated Voltage Measurement... 10:58:50 Voltage Offset Correction: v_off_ini = 214.180 uV, v_off_fin = 219.509 uV 10:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.231 uVs 10:58:54 I1X Average and RMS of Measurements VT = -64.166 +- 9.026 uVs I1X = 12.833 +- 1.805 uTm 10:58:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:59:01 Integrated Voltage Measurement... 10:59:10 Voltage Offset Correction: v_off_ini = 202.637 uV, v_off_fin = 209.565 uV 10:59:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -236.783 uVs 10:59:10 Integrated Voltage Measurement... 10:59:19 Voltage Offset Correction: v_off_ini = 202.692 uV, v_off_fin = 218.540 uV 10:59:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.908 uVs 10:59:19 Integrated Voltage Measurement... 10:59:28 Voltage Offset Correction: v_off_ini = 214.296 uV, v_off_fin = 210.949 uV 10:59:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.723 uVs 10:59:28 Integrated Voltage Measurement... 10:59:37 Voltage Offset Correction: v_off_ini = 220.469 uV, v_off_fin = 224.362 uV 10:59:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.608 uVs 10:59:37 Integrated Voltage Measurement... 10:59:46 Voltage Offset Correction: v_off_ini = 206.906 uV, v_off_fin = 202.754 uV 10:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.376 uVs 10:59:46 Integrated Voltage Measurement... 10:59:55 Voltage Offset Correction: v_off_ini = 204.298 uV, v_off_fin = 215.024 uV 10:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.938 uVs 10:59:59 I1Y Average and RMS of Measurements VT = -235.389 +- 3.380 uVs I1Y = -47.079 +- 0.677 uTm 11:00:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:00:07 Integrated Voltage Measurement... 11:00:16 Voltage Offset Correction: v_off_ini = 210.248 uV, v_off_fin = 202.237 uV 11:00:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.869 uVs 11:00:16 Integrated Voltage Measurement... 11:00:25 Voltage Offset Correction: v_off_ini = 221.797 uV, v_off_fin = 217.374 uV 11:00:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.770 uVs 11:00:25 Integrated Voltage Measurement... 11:00:34 Voltage Offset Correction: v_off_ini = 200.780 uV, v_off_fin = 199.097 uV 11:00:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.698 uVs 11:00:34 Integrated Voltage Measurement... 11:00:43 Voltage Offset Correction: v_off_ini = 195.563 uV, v_off_fin = 217.767 uV 11:00:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.625 uVs 11:00:43 Integrated Voltage Measurement... 11:00:52 Voltage Offset Correction: v_off_ini = 229.040 uV, v_off_fin = 211.464 uV 11:00:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.241 uVs 11:00:52 Integrated Voltage Measurement... 11:01:01 Voltage Offset Correction: v_off_ini = 222.728 uV, v_off_fin = 232.749 uV 11:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.528 uVs 11:01:03 I2X Average and RMS of Measurements VT = -79.789 +- 4.926 uVs I2X = 7.341 +- 0.453 uTm^2 11:01:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:01:11 Integrated Voltage Measurement... 11:01:20 Voltage Offset Correction: v_off_ini = 217.239 uV, v_off_fin = 202.368 uV 11:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.820 uVs 11:01:20 Integrated Voltage Measurement... 11:01:29 Voltage Offset Correction: v_off_ini = 200.960 uV, v_off_fin = 201.163 uV 11:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.611 uVs 11:01:29 Integrated Voltage Measurement... 11:01:38 Voltage Offset Correction: v_off_ini = 203.918 uV, v_off_fin = 197.999 uV 11:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.209 uVs 11:01:38 Integrated Voltage Measurement... 11:01:47 Voltage Offset Correction: v_off_ini = 199.851 uV, v_off_fin = 197.191 uV 11:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.839 uVs 11:01:47 Integrated Voltage Measurement... 11:01:56 Voltage Offset Correction: v_off_ini = 200.128 uV, v_off_fin = 199.069 uV 11:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.486 uVs 11:01:56 Integrated Voltage Measurement... 11:02:05 Voltage Offset Correction: v_off_ini = 203.015 uV, v_off_fin = 192.225 uV 11:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.065 uVs 11:02:08 I2Y Average and RMS of Measurements VT = -292.505 +- 5.569 uVs I2Y = -26.910 +- 0.512 uTm^2 11:02:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:02:17 Integrated Voltage Measurement... 11:02:25 Voltage Offset Correction: v_off_ini = 207.177 uV, v_off_fin = 179.928 uV 11:02:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -47.725 uVs 11:02:26 Integrated Voltage Measurement... 11:02:34 Voltage Offset Correction: v_off_ini = 189.075 uV, v_off_fin = 188.504 uV 11:02:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 59.249 uVs 11:02:35 Integrated Voltage Measurement... 11:02:43 Voltage Offset Correction: v_off_ini = 191.545 uV, v_off_fin = 188.810 uV 11:02:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.819 uVs 11:02:44 Integrated Voltage Measurement... 11:02:52 Voltage Offset Correction: v_off_ini = 189.378 uV, v_off_fin = 195.805 uV 11:02:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.341 uVs 11:02:53 Integrated Voltage Measurement... 11:03:01 Voltage Offset Correction: v_off_ini = 193.348 uV, v_off_fin = 189.275 uV 11:03:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.276 uVs 11:03:02 Integrated Voltage Measurement... 11:03:10 Voltage Offset Correction: v_off_ini = 215.721 uV, v_off_fin = 218.015 uV 11:03:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.587 uVs 11:03:15 I1X Average and RMS of Measurements VT = -53.333 +- 0.682 uVs I1X = 10.667 +- 0.136 uTm 11:03:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:03:22 Integrated Voltage Measurement... 11:03:30 Voltage Offset Correction: v_off_ini = 208.642 uV, v_off_fin = 205.552 uV 11:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -225.915 uVs 11:03:30 Integrated Voltage Measurement... 11:03:39 Voltage Offset Correction: v_off_ini = 230.045 uV, v_off_fin = 231.857 uV 11:03:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.874 uVs 11:03:39 Integrated Voltage Measurement... 11:03:48 Voltage Offset Correction: v_off_ini = 205.412 uV, v_off_fin = 196.549 uV 11:03:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -216.497 uVs 11:03:48 Integrated Voltage Measurement... 11:03:57 Voltage Offset Correction: v_off_ini = 218.787 uV, v_off_fin = 229.824 uV 11:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.897 uVs 11:03:57 Integrated Voltage Measurement... 11:04:06 Voltage Offset Correction: v_off_ini = 207.230 uV, v_off_fin = 202.496 uV 11:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.920 uVs 11:04:06 Integrated Voltage Measurement... 11:04:15 Voltage Offset Correction: v_off_ini = 214.307 uV, v_off_fin = 206.416 uV 11:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.141 uVs 11:04:20 I1Y Average and RMS of Measurements VT = -222.707 +- 4.865 uVs I1Y = -44.543 +- 0.972 uTm 11:04:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:04:27 Integrated Voltage Measurement... 11:04:36 Voltage Offset Correction: v_off_ini = 219.788 uV, v_off_fin = 211.734 uV 11:04:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.850 uVs 11:04:36 Integrated Voltage Measurement... 11:04:45 Voltage Offset Correction: v_off_ini = 237.048 uV, v_off_fin = 245.796 uV 11:04:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.343 uVs 11:04:45 Integrated Voltage Measurement... 11:04:54 Voltage Offset Correction: v_off_ini = 233.255 uV, v_off_fin = 217.060 uV 11:04:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.480 uVs 11:04:54 Integrated Voltage Measurement... 11:05:03 Voltage Offset Correction: v_off_ini = 219.027 uV, v_off_fin = 232.170 uV 11:05:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.471 uVs 11:05:03 Integrated Voltage Measurement... 11:05:12 Voltage Offset Correction: v_off_ini = 223.237 uV, v_off_fin = 206.231 uV 11:05:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -68.296 uVs 11:05:12 Integrated Voltage Measurement... 11:05:21 Voltage Offset Correction: v_off_ini = 216.489 uV, v_off_fin = 226.438 uV 11:05:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.865 uVs 11:05:24 I2X Average and RMS of Measurements VT = -69.384 +- 2.094 uVs I2X = 6.384 +- 0.193 uTm^2 11:05:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:05:32 Integrated Voltage Measurement... 11:05:41 Voltage Offset Correction: v_off_ini = 223.200 uV, v_off_fin = 218.147 uV 11:05:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.892 uVs 11:05:41 Integrated Voltage Measurement... 11:05:50 Voltage Offset Correction: v_off_ini = 221.833 uV, v_off_fin = 223.068 uV 11:05:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.270 uVs 11:05:50 Integrated Voltage Measurement... 11:05:59 Voltage Offset Correction: v_off_ini = 227.987 uV, v_off_fin = 214.812 uV 11:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.427 uVs 11:05:59 Integrated Voltage Measurement... 11:06:08 Voltage Offset Correction: v_off_ini = 214.376 uV, v_off_fin = 218.180 uV 11:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.556 uVs 11:06:08 Integrated Voltage Measurement... 11:06:17 Voltage Offset Correction: v_off_ini = 220.282 uV, v_off_fin = 222.256 uV 11:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.890 uVs 11:06:17 Integrated Voltage Measurement... 11:06:26 Voltage Offset Correction: v_off_ini = 211.797 uV, v_off_fin = 225.078 uV 11:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.474 uVs 11:06:28 I2Y Average and RMS of Measurements VT = -286.752 +- 6.131 uVs I2Y = -26.381 +- 0.564 uTm^2 11:06:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:06:40 Integrated Voltage Measurement... 11:06:49 Voltage Offset Correction: v_off_ini = 222.672 uV, v_off_fin = 214.717 uV 11:06:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.725 uVs 11:06:49 Integrated Voltage Measurement... 11:06:58 Voltage Offset Correction: v_off_ini = 218.305 uV, v_off_fin = 218.084 uV 11:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.067 uVs 11:06:58 Integrated Voltage Measurement... 11:07:07 Voltage Offset Correction: v_off_ini = 216.112 uV, v_off_fin = 212.879 uV 11:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.422 uVs 11:07:07 Integrated Voltage Measurement... 11:07:16 Voltage Offset Correction: v_off_ini = 220.198 uV, v_off_fin = 229.105 uV 11:07:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.362 uVs 11:07:16 Integrated Voltage Measurement... 11:07:25 Voltage Offset Correction: v_off_ini = 219.623 uV, v_off_fin = 215.658 uV 11:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.580 uVs 11:07:25 Integrated Voltage Measurement... 11:07:34 Voltage Offset Correction: v_off_ini = 223.047 uV, v_off_fin = 228.662 uV 11:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 68.848 uVs 11:07:38 I1X Average and RMS of Measurements VT = -55.334 +- 5.276 uVs I1X = 11.067 +- 1.056 uTm 11:07:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:07:45 Integrated Voltage Measurement... 11:07:54 Voltage Offset Correction: v_off_ini = 220.562 uV, v_off_fin = 212.112 uV 11:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.793 uVs 11:07:54 Integrated Voltage Measurement... 11:08:03 Voltage Offset Correction: v_off_ini = 227.002 uV, v_off_fin = 238.395 uV 11:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.682 uVs 11:08:03 Integrated Voltage Measurement... 11:08:12 Voltage Offset Correction: v_off_ini = 221.342 uV, v_off_fin = 212.005 uV 11:08:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.340 uVs 11:08:12 Integrated Voltage Measurement... 11:08:21 Voltage Offset Correction: v_off_ini = 224.874 uV, v_off_fin = 236.948 uV 11:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.931 uVs 11:08:21 Integrated Voltage Measurement... 11:08:30 Voltage Offset Correction: v_off_ini = 231.707 uV, v_off_fin = 212.594 uV 11:08:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.308 uVs 11:08:30 Integrated Voltage Measurement... 11:08:39 Voltage Offset Correction: v_off_ini = 229.333 uV, v_off_fin = 231.690 uV 11:08:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.759 uVs 11:08:43 I1Y Average and RMS of Measurements VT = -230.802 +- 4.507 uVs I1Y = -46.160 +- 0.901 uTm 11:08:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:08:48 Integrated Voltage Measurement... 11:08:57 Voltage Offset Correction: v_off_ini = 237.636 uV, v_off_fin = 232.571 uV 11:08:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.944 uVs 11:08:57 Integrated Voltage Measurement... 11:09:06 Voltage Offset Correction: v_off_ini = 244.244 uV, v_off_fin = 260.715 uV 11:09:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.596 uVs 11:09:06 Integrated Voltage Measurement... 11:09:15 Voltage Offset Correction: v_off_ini = 249.027 uV, v_off_fin = 234.028 uV 11:09:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.260 uVs 11:09:15 Integrated Voltage Measurement... 11:09:24 Voltage Offset Correction: v_off_ini = 238.677 uV, v_off_fin = 249.425 uV 11:09:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.077 uVs 11:09:24 Integrated Voltage Measurement... 11:09:33 Voltage Offset Correction: v_off_ini = 232.341 uV, v_off_fin = 235.453 uV 11:09:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.360 uVs 11:09:33 Integrated Voltage Measurement... 11:09:42 Voltage Offset Correction: v_off_ini = 238.106 uV, v_off_fin = 257.202 uV 11:09:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.502 uVs 11:09:45 I2X Average and RMS of Measurements VT = -68.290 +- 13.863 uVs I2X = 6.283 +- 1.275 uTm^2 11:09:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:09:50 Integrated Voltage Measurement... 11:09:59 Voltage Offset Correction: v_off_ini = 266.668 uV, v_off_fin = 258.763 uV 11:09:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.933 uVs 11:09:59 Integrated Voltage Measurement... 11:10:08 Voltage Offset Correction: v_off_ini = 242.779 uV, v_off_fin = 250.978 uV 11:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.755 uVs 11:10:08 Integrated Voltage Measurement... 11:10:17 Voltage Offset Correction: v_off_ini = 250.308 uV, v_off_fin = 240.210 uV 11:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.908 uVs 11:10:17 Integrated Voltage Measurement... 11:10:26 Voltage Offset Correction: v_off_ini = 247.147 uV, v_off_fin = 246.756 uV 11:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.005 uVs 11:10:26 Integrated Voltage Measurement... 11:10:35 Voltage Offset Correction: v_off_ini = 256.972 uV, v_off_fin = 250.081 uV 11:10:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.271 uVs 11:10:35 Integrated Voltage Measurement... 11:10:44 Voltage Offset Correction: v_off_ini = 246.673 uV, v_off_fin = 242.552 uV 11:10:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.611 uVs 11:10:46 I2Y Average and RMS of Measurements VT = -298.247 +- 2.768 uVs I2Y = -27.439 +- 0.255 uTm^2 11:10:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:10:55 Integrated Voltage Measurement... 11:11:04 Voltage Offset Correction: v_off_ini = 243.527 uV, v_off_fin = 241.574 uV 11:11:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.834 uVs 11:11:04 Integrated Voltage Measurement... 11:11:13 Voltage Offset Correction: v_off_ini = 250.194 uV, v_off_fin = 251.962 uV 11:11:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.676 uVs 11:11:13 Integrated Voltage Measurement... 11:11:22 Voltage Offset Correction: v_off_ini = 253.174 uV, v_off_fin = 229.005 uV 11:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.687 uVs 11:11:22 Integrated Voltage Measurement... 11:11:31 Voltage Offset Correction: v_off_ini = 236.757 uV, v_off_fin = 234.815 uV 11:11:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.817 uVs 11:11:31 Integrated Voltage Measurement... 11:11:40 Voltage Offset Correction: v_off_ini = 229.254 uV, v_off_fin = 227.831 uV 11:11:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.618 uVs 11:11:40 Integrated Voltage Measurement... 11:11:49 Voltage Offset Correction: v_off_ini = 234.930 uV, v_off_fin = 238.102 uV 11:11:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.494 uVs 11:11:53 I1X Average and RMS of Measurements VT = -63.021 +- 4.521 uVs I1X = 12.604 +- 0.904 uTm 11:11:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:12:00 Integrated Voltage Measurement... 11:12:09 Voltage Offset Correction: v_off_ini = 241.488 uV, v_off_fin = 246.188 uV 11:12:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.996 uVs 11:12:09 Integrated Voltage Measurement... 11:12:18 Voltage Offset Correction: v_off_ini = 261.957 uV, v_off_fin = 265.072 uV 11:12:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.779 uVs 11:12:18 Integrated Voltage Measurement... 11:12:27 Voltage Offset Correction: v_off_ini = 258.909 uV, v_off_fin = 244.928 uV 11:12:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.048 uVs 11:12:27 Integrated Voltage Measurement... 11:12:36 Voltage Offset Correction: v_off_ini = 244.605 uV, v_off_fin = 256.594 uV 11:12:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.522 uVs 11:12:36 Integrated Voltage Measurement... 11:12:45 Voltage Offset Correction: v_off_ini = 247.899 uV, v_off_fin = 230.947 uV 11:12:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.234 uVs 11:12:45 Integrated Voltage Measurement... 11:12:54 Voltage Offset Correction: v_off_ini = 232.068 uV, v_off_fin = 237.457 uV 11:12:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.564 uVs 11:12:58 I1Y Average and RMS of Measurements VT = -235.524 +- 2.509 uVs I1Y = -47.105 +- 0.502 uTm 11:13:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:13:03 Integrated Voltage Measurement... 11:13:12 Voltage Offset Correction: v_off_ini = 253.324 uV, v_off_fin = 240.151 uV 11:13:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.491 uVs 11:13:12 Integrated Voltage Measurement... 11:13:21 Voltage Offset Correction: v_off_ini = 250.758 uV, v_off_fin = 263.776 uV 11:13:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.443 uVs 11:13:21 Integrated Voltage Measurement... 11:13:30 Voltage Offset Correction: v_off_ini = 249.719 uV, v_off_fin = 240.285 uV 11:13:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.056 uVs 11:13:30 Integrated Voltage Measurement... 11:13:39 Voltage Offset Correction: v_off_ini = 256.368 uV, v_off_fin = 245.964 uV 11:13:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.139 uVs 11:13:39 Integrated Voltage Measurement... 11:13:48 Voltage Offset Correction: v_off_ini = 248.770 uV, v_off_fin = 239.568 uV 11:13:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.934 uVs 11:13:48 Integrated Voltage Measurement... 11:13:57 Voltage Offset Correction: v_off_ini = 251.824 uV, v_off_fin = 250.160 uV 11:13:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.674 uVs 11:13:59 I2X Average and RMS of Measurements VT = -85.123 +- 5.257 uVs I2X = 7.832 +- 0.484 uTm^2 11:14:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:14:05 Integrated Voltage Measurement... 11:14:13 Voltage Offset Correction: v_off_ini = 255.047 uV, v_off_fin = 246.424 uV 11:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.032 uVs 11:14:14 Integrated Voltage Measurement... 11:14:22 Voltage Offset Correction: v_off_ini = 245.345 uV, v_off_fin = 253.926 uV 11:14:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.518 uVs 11:14:23 Integrated Voltage Measurement... 11:14:32 Voltage Offset Correction: v_off_ini = 252.622 uV, v_off_fin = 254.530 uV 11:14:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.193 uVs 11:14:32 Integrated Voltage Measurement... 11:14:41 Voltage Offset Correction: v_off_ini = 249.008 uV, v_off_fin = 254.353 uV 11:14:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.665 uVs 11:14:41 Integrated Voltage Measurement... 11:14:50 Voltage Offset Correction: v_off_ini = 260.076 uV, v_off_fin = 257.713 uV 11:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.302 uVs 11:14:50 Integrated Voltage Measurement... 11:14:59 Voltage Offset Correction: v_off_ini = 259.408 uV, v_off_fin = 262.183 uV 11:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.184 uVs 11:15:01 I2Y Average and RMS of Measurements VT = -294.649 +- 0.656 uVs I2Y = -27.108 +- 0.060 uTm^2 11:15:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:09 Integrated Voltage Measurement... 11:15:18 Voltage Offset Correction: v_off_ini = 272.225 uV, v_off_fin = 258.180 uV 11:15:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.726 uVs 11:15:18 Integrated Voltage Measurement... 11:15:27 Voltage Offset Correction: v_off_ini = 265.661 uV, v_off_fin = 261.996 uV 11:15:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.944 uVs 11:15:27 Integrated Voltage Measurement... 11:15:36 Voltage Offset Correction: v_off_ini = 246.856 uV, v_off_fin = 248.040 uV 11:15:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.732 uVs 11:15:36 Integrated Voltage Measurement... 11:15:45 Voltage Offset Correction: v_off_ini = 251.741 uV, v_off_fin = 254.409 uV 11:15:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.134 uVs 11:15:46 Integrated Voltage Measurement... 11:15:54 Voltage Offset Correction: v_off_ini = 265.556 uV, v_off_fin = 255.439 uV 11:15:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.303 uVs 11:15:55 Integrated Voltage Measurement... 11:16:03 Voltage Offset Correction: v_off_ini = 258.643 uV, v_off_fin = 247.898 uV 11:16:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.036 uVs 11:16:08 I1X Average and RMS of Measurements VT = -69.479 +- 8.888 uVs I1X = 13.896 +- 1.778 uTm 11:16:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:16:15 Integrated Voltage Measurement... 11:16:23 Voltage Offset Correction: v_off_ini = 247.496 uV, v_off_fin = 242.776 uV 11:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.621 uVs 11:16:24 Integrated Voltage Measurement... 11:16:32 Voltage Offset Correction: v_off_ini = 252.461 uV, v_off_fin = 254.297 uV 11:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.785 uVs 11:16:32 Integrated Voltage Measurement... 11:16:41 Voltage Offset Correction: v_off_ini = 246.204 uV, v_off_fin = 244.610 uV 11:16:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.202 uVs 11:16:41 Integrated Voltage Measurement... 11:16:50 Voltage Offset Correction: v_off_ini = 251.777 uV, v_off_fin = 254.022 uV 11:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.852 uVs 11:16:50 Integrated Voltage Measurement... 11:16:59 Voltage Offset Correction: v_off_ini = 238.521 uV, v_off_fin = 232.852 uV 11:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.841 uVs 11:16:59 Integrated Voltage Measurement... 11:17:08 Voltage Offset Correction: v_off_ini = 249.467 uV, v_off_fin = 264.627 uV 11:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.046 uVs 11:17:13 I1Y Average and RMS of Measurements VT = -226.225 +- 2.443 uVs I1Y = -45.245 +- 0.489 uTm 11:17:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:18 Integrated Voltage Measurement... 11:17:27 Voltage Offset Correction: v_off_ini = 243.357 uV, v_off_fin = 234.197 uV 11:17:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.788 uVs 11:17:27 Integrated Voltage Measurement... 11:17:36 Voltage Offset Correction: v_off_ini = 238.808 uV, v_off_fin = 244.022 uV 11:17:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.617 uVs 11:17:36 Integrated Voltage Measurement... 11:17:45 Voltage Offset Correction: v_off_ini = 236.782 uV, v_off_fin = 226.210 uV 11:17:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.475 uVs 11:17:45 Integrated Voltage Measurement... 11:17:54 Voltage Offset Correction: v_off_ini = 224.242 uV, v_off_fin = 242.015 uV 11:17:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.815 uVs 11:17:54 Integrated Voltage Measurement... 11:18:03 Voltage Offset Correction: v_off_ini = 222.081 uV, v_off_fin = 218.299 uV 11:18:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.242 uVs 11:18:03 Integrated Voltage Measurement... 11:18:12 Voltage Offset Correction: v_off_ini = 232.993 uV, v_off_fin = 241.271 uV 11:18:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.081 uVs 11:18:14 I2X Average and RMS of Measurements VT = -79.503 +- 7.579 uVs I2X = 7.314 +- 0.697 uTm^2 11:18:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:19 Integrated Voltage Measurement... 11:18:28 Voltage Offset Correction: v_off_ini = 240.336 uV, v_off_fin = 232.636 uV 11:18:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.310 uVs 11:18:29 Integrated Voltage Measurement... 11:18:37 Voltage Offset Correction: v_off_ini = 229.265 uV, v_off_fin = 234.839 uV 11:18:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.336 uVs 11:18:38 Integrated Voltage Measurement... 11:18:47 Voltage Offset Correction: v_off_ini = 233.585 uV, v_off_fin = 225.447 uV 11:18:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.014 uVs 11:18:47 Integrated Voltage Measurement... 11:18:56 Voltage Offset Correction: v_off_ini = 224.212 uV, v_off_fin = 213.862 uV 11:18:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.302 uVs 11:18:56 Integrated Voltage Measurement... 11:19:05 Voltage Offset Correction: v_off_ini = 223.913 uV, v_off_fin = 226.949 uV 11:19:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.914 uVs 11:19:05 Integrated Voltage Measurement... 11:19:14 Voltage Offset Correction: v_off_ini = 221.957 uV, v_off_fin = 234.758 uV 11:19:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.663 uVs 11:19:16 I2Y Average and RMS of Measurements VT = -291.423 +- 2.816 uVs I2Y = -26.811 +- 0.259 uTm^2 11:19:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:19:24 Integrated Voltage Measurement... 11:19:33 Voltage Offset Correction: v_off_ini = 226.861 uV, v_off_fin = 210.979 uV 11:19:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -53.303 uVs 11:19:33 Integrated Voltage Measurement... 11:19:42 Voltage Offset Correction: v_off_ini = 218.647 uV, v_off_fin = 217.865 uV 11:19:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.875 uVs 11:19:42 Integrated Voltage Measurement... 11:19:51 Voltage Offset Correction: v_off_ini = 231.409 uV, v_off_fin = 224.183 uV 11:19:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.253 uVs 11:19:51 Integrated Voltage Measurement... 11:20:00 Voltage Offset Correction: v_off_ini = 223.172 uV, v_off_fin = 231.459 uV 11:20:00 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 79.070 uVs 11:20:00 Integrated Voltage Measurement... 11:20:09 Voltage Offset Correction: v_off_ini = 226.862 uV, v_off_fin = 212.616 uV 11:20:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.620 uVs 11:20:09 Integrated Voltage Measurement... 11:20:18 Voltage Offset Correction: v_off_ini = 224.585 uV, v_off_fin = 228.671 uV 11:20:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.996 uVs 11:20:23 I1X Average and RMS of Measurements VT = -57.686 +- 7.912 uVs I1X = 11.538 +- 1.583 uTm 11:20:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:20:29 Integrated Voltage Measurement... 11:20:38 Voltage Offset Correction: v_off_ini = 228.821 uV, v_off_fin = 216.598 uV 11:20:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.229 uVs 11:20:38 Integrated Voltage Measurement... 11:20:47 Voltage Offset Correction: v_off_ini = 217.456 uV, v_off_fin = 234.319 uV 11:20:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.084 uVs 11:20:47 Integrated Voltage Measurement... 11:20:56 Voltage Offset Correction: v_off_ini = 231.031 uV, v_off_fin = 223.158 uV 11:20:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.441 uVs 11:20:56 Integrated Voltage Measurement... 11:21:05 Voltage Offset Correction: v_off_ini = 248.569 uV, v_off_fin = 255.567 uV 11:21:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.213 uVs 11:21:05 Integrated Voltage Measurement... 11:21:14 Voltage Offset Correction: v_off_ini = 241.658 uV, v_off_fin = 231.653 uV 11:21:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.145 uVs 11:21:14 Integrated Voltage Measurement... 11:21:23 Voltage Offset Correction: v_off_ini = 242.322 uV, v_off_fin = 256.904 uV 11:21:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.014 uVs 11:21:28 I1Y Average and RMS of Measurements VT = -216.354 +- 8.919 uVs I1Y = -43.271 +- 1.784 uTm 11:21:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:21:33 Integrated Voltage Measurement... 11:21:42 Voltage Offset Correction: v_off_ini = 249.031 uV, v_off_fin = 245.767 uV 11:21:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.970 uVs 11:21:42 Integrated Voltage Measurement... 11:21:51 Voltage Offset Correction: v_off_ini = 248.533 uV, v_off_fin = 256.575 uV 11:21:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.250 uVs 11:21:51 Integrated Voltage Measurement... 11:22:00 Voltage Offset Correction: v_off_ini = 241.876 uV, v_off_fin = 233.174 uV 11:22:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.281 uVs 11:22:00 Integrated Voltage Measurement... 11:22:09 Voltage Offset Correction: v_off_ini = 251.655 uV, v_off_fin = 242.297 uV 11:22:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.406 uVs 11:22:09 Integrated Voltage Measurement... 11:22:18 Voltage Offset Correction: v_off_ini = 247.593 uV, v_off_fin = 234.797 uV 11:22:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.076 uVs 11:22:18 Integrated Voltage Measurement... 11:22:27 Voltage Offset Correction: v_off_ini = 256.237 uV, v_off_fin = 261.073 uV 11:22:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.168 uVs 11:22:29 I2X Average and RMS of Measurements VT = -85.525 +- 6.464 uVs I2X = 7.868 +- 0.595 uTm^2 11:22:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:22:34 Integrated Voltage Measurement... 11:22:43 Voltage Offset Correction: v_off_ini = 243.220 uV, v_off_fin = 247.328 uV 11:22:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.652 uVs 11:22:44 Integrated Voltage Measurement... 11:22:52 Voltage Offset Correction: v_off_ini = 254.894 uV, v_off_fin = 246.241 uV 11:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.656 uVs 11:22:53 Integrated Voltage Measurement... 11:23:02 Voltage Offset Correction: v_off_ini = 257.290 uV, v_off_fin = 258.362 uV 11:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.964 uVs 11:23:02 Integrated Voltage Measurement... 11:23:11 Voltage Offset Correction: v_off_ini = 255.395 uV, v_off_fin = 252.848 uV 11:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.580 uVs 11:23:11 Integrated Voltage Measurement... 11:23:20 Voltage Offset Correction: v_off_ini = 250.843 uV, v_off_fin = 230.212 uV 11:23:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.112 uVs 11:23:20 Integrated Voltage Measurement... 11:23:29 Voltage Offset Correction: v_off_ini = 239.130 uV, v_off_fin = 252.952 uV 11:23:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.224 uVs 11:23:31 I2Y Average and RMS of Measurements VT = -289.031 +- 3.514 uVs I2Y = -26.591 +- 0.323 uTm^2 11:23:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:23:39 Integrated Voltage Measurement... 11:23:48 Voltage Offset Correction: v_off_ini = 251.720 uV, v_off_fin = 243.142 uV 11:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.351 uVs 11:23:48 Integrated Voltage Measurement... 11:23:57 Voltage Offset Correction: v_off_ini = 254.218 uV, v_off_fin = 264.714 uV 11:23:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.547 uVs 11:23:57 Integrated Voltage Measurement... 11:24:06 Voltage Offset Correction: v_off_ini = 253.035 uV, v_off_fin = 249.010 uV 11:24:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.222 uVs 11:24:06 Integrated Voltage Measurement... 11:24:15 Voltage Offset Correction: v_off_ini = 260.931 uV, v_off_fin = 266.145 uV 11:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.151 uVs 11:24:16 Integrated Voltage Measurement... 11:24:24 Voltage Offset Correction: v_off_ini = 268.897 uV, v_off_fin = 260.553 uV 11:24:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.650 uVs 11:24:25 Integrated Voltage Measurement... 11:24:33 Voltage Offset Correction: v_off_ini = 269.553 uV, v_off_fin = 279.884 uV 11:24:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.528 uVs 11:24:38 I1X Average and RMS of Measurements VT = -59.908 +- 7.258 uVs I1X = 11.982 +- 1.451 uTm 11:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:24:44 Integrated Voltage Measurement... 11:24:53 Voltage Offset Correction: v_off_ini = 264.490 uV, v_off_fin = 248.280 uV 11:24:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.486 uVs 11:24:54 Integrated Voltage Measurement... 11:25:02 Voltage Offset Correction: v_off_ini = 263.918 uV, v_off_fin = 278.273 uV 11:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.510 uVs 11:25:03 Integrated Voltage Measurement... 11:25:11 Voltage Offset Correction: v_off_ini = 259.550 uV, v_off_fin = 246.105 uV 11:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.539 uVs 11:25:11 Integrated Voltage Measurement... 11:25:20 Voltage Offset Correction: v_off_ini = 261.085 uV, v_off_fin = 272.715 uV 11:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.179 uVs 11:25:20 Integrated Voltage Measurement... 11:25:29 Voltage Offset Correction: v_off_ini = 266.350 uV, v_off_fin = 244.968 uV 11:25:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.958 uVs 11:25:29 Integrated Voltage Measurement... 11:25:38 Voltage Offset Correction: v_off_ini = 244.692 uV, v_off_fin = 266.196 uV 11:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.055 uVs 11:25:43 I1Y Average and RMS of Measurements VT = -220.621 +- 2.505 uVs I1Y = -44.121 +- 0.500 uTm 11:25:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:25:48 Integrated Voltage Measurement... 11:25:57 Voltage Offset Correction: v_off_ini = 262.264 uV, v_off_fin = 251.017 uV 11:25:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.453 uVs 11:25:57 Integrated Voltage Measurement... 11:26:06 Voltage Offset Correction: v_off_ini = 253.652 uV, v_off_fin = 267.968 uV 11:26:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.635 uVs 11:26:06 Integrated Voltage Measurement... 11:26:15 Voltage Offset Correction: v_off_ini = 262.145 uV, v_off_fin = 246.724 uV 11:26:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.694 uVs 11:26:15 Integrated Voltage Measurement... 11:26:24 Voltage Offset Correction: v_off_ini = 252.461 uV, v_off_fin = 269.535 uV 11:26:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.487 uVs 11:26:24 Integrated Voltage Measurement... 11:26:33 Voltage Offset Correction: v_off_ini = 255.293 uV, v_off_fin = 241.645 uV 11:26:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.272 uVs 11:26:33 Integrated Voltage Measurement... 11:26:42 Voltage Offset Correction: v_off_ini = 257.235 uV, v_off_fin = 268.733 uV 11:26:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.743 uVs 11:26:44 I2X Average and RMS of Measurements VT = -85.214 +- 3.956 uVs I2X = 7.840 +- 0.364 uTm^2 11:26:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:26:49 Integrated Voltage Measurement... 11:26:58 Voltage Offset Correction: v_off_ini = 254.614 uV, v_off_fin = 251.882 uV 11:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.330 uVs 11:26:58 Integrated Voltage Measurement... 11:27:07 Voltage Offset Correction: v_off_ini = 252.912 uV, v_off_fin = 258.840 uV 11:27:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.581 uVs 11:27:08 Integrated Voltage Measurement... 11:27:16 Voltage Offset Correction: v_off_ini = 238.272 uV, v_off_fin = 245.879 uV 11:27:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.935 uVs 11:27:17 Integrated Voltage Measurement... 11:27:26 Voltage Offset Correction: v_off_ini = 246.589 uV, v_off_fin = 258.225 uV 11:27:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.230 uVs 11:27:26 Integrated Voltage Measurement... 11:27:35 Voltage Offset Correction: v_off_ini = 249.021 uV, v_off_fin = 252.841 uV 11:27:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.051 uVs 11:27:35 Integrated Voltage Measurement... 11:27:44 Voltage Offset Correction: v_off_ini = 248.216 uV, v_off_fin = 255.710 uV 11:27:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.522 uVs 11:27:46 I2Y Average and RMS of Measurements VT = -280.275 +- 4.318 uVs I2Y = -25.785 +- 0.397 uTm^2 11:28:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:28:07 Integrated Voltage Measurement... 11:28:16 Voltage Offset Correction: v_off_ini = 246.815 uV, v_off_fin = 242.361 uV 11:28:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.393 uVs 11:28:16 Integrated Voltage Measurement... 11:28:25 Voltage Offset Correction: v_off_ini = 264.283 uV, v_off_fin = 250.515 uV 11:28:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.292 uVs 11:28:25 Integrated Voltage Measurement... 11:28:34 Voltage Offset Correction: v_off_ini = 235.913 uV, v_off_fin = 242.065 uV 11:28:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.720 uVs 11:28:34 Integrated Voltage Measurement... 11:28:43 Voltage Offset Correction: v_off_ini = 244.007 uV, v_off_fin = 243.733 uV 11:28:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.473 uVs 11:28:43 Integrated Voltage Measurement... 11:28:52 Voltage Offset Correction: v_off_ini = 247.320 uV, v_off_fin = 237.127 uV 11:28:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.359 uVs 11:28:52 Integrated Voltage Measurement... 11:29:01 Voltage Offset Correction: v_off_ini = 234.920 uV, v_off_fin = 232.406 uV 11:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.684 uVs 11:29:06 I1X Average and RMS of Measurements VT = -70.987 +- 7.362 uVs I1X = 14.197 +- 1.472 uTm 11:29:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:29:12 Integrated Voltage Measurement... 11:29:21 Voltage Offset Correction: v_off_ini = 247.069 uV, v_off_fin = 232.908 uV 11:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.249 uVs 11:29:21 Integrated Voltage Measurement... 11:29:30 Voltage Offset Correction: v_off_ini = 232.269 uV, v_off_fin = 247.673 uV 11:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.738 uVs 11:29:30 Integrated Voltage Measurement... 11:29:39 Voltage Offset Correction: v_off_ini = 246.164 uV, v_off_fin = 235.908 uV 11:29:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -243.617 uVs 11:29:39 Integrated Voltage Measurement... 11:29:48 Voltage Offset Correction: v_off_ini = 242.083 uV, v_off_fin = 249.662 uV 11:29:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.607 uVs 11:29:48 Integrated Voltage Measurement... 11:29:57 Voltage Offset Correction: v_off_ini = 238.545 uV, v_off_fin = 237.221 uV 11:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.887 uVs 11:29:57 Integrated Voltage Measurement... 11:30:06 Voltage Offset Correction: v_off_ini = 248.272 uV, v_off_fin = 256.037 uV 11:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.771 uVs 11:30:11 I1Y Average and RMS of Measurements VT = -256.145 +- 5.260 uVs I1Y = -51.230 +- 1.051 uTm 11:30:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:30:18 Integrated Voltage Measurement... 11:30:27 Voltage Offset Correction: v_off_ini = 227.125 uV, v_off_fin = 211.282 uV 11:30:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.785 uVs 11:30:27 Integrated Voltage Measurement... 11:30:36 Voltage Offset Correction: v_off_ini = 215.745 uV, v_off_fin = 240.209 uV 11:30:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.263 uVs 11:30:36 Integrated Voltage Measurement... 11:30:45 Voltage Offset Correction: v_off_ini = 220.848 uV, v_off_fin = 211.516 uV 11:30:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.985 uVs 11:30:45 Integrated Voltage Measurement... 11:30:54 Voltage Offset Correction: v_off_ini = 229.969 uV, v_off_fin = 246.745 uV 11:30:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.061 uVs 11:30:54 Integrated Voltage Measurement... 11:31:03 Voltage Offset Correction: v_off_ini = 219.717 uV, v_off_fin = 214.423 uV 11:31:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.324 uVs 11:31:03 Integrated Voltage Measurement... 11:31:12 Voltage Offset Correction: v_off_ini = 235.118 uV, v_off_fin = 247.823 uV 11:31:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.707 uVs 11:31:15 I2X Average and RMS of Measurements VT = -97.688 +- 5.717 uVs I2X = 8.987 +- 0.526 uTm^2 11:31:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:31:23 Integrated Voltage Measurement... 11:31:32 Voltage Offset Correction: v_off_ini = 238.511 uV, v_off_fin = 231.256 uV 11:31:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.706 uVs 11:31:32 Integrated Voltage Measurement... 11:31:41 Voltage Offset Correction: v_off_ini = 228.865 uV, v_off_fin = 236.229 uV 11:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.247 uVs 11:31:41 Integrated Voltage Measurement... 11:31:50 Voltage Offset Correction: v_off_ini = 250.204 uV, v_off_fin = 233.285 uV 11:31:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.911 uVs 11:31:50 Integrated Voltage Measurement... 11:31:59 Voltage Offset Correction: v_off_ini = 248.708 uV, v_off_fin = 253.850 uV 11:31:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.126 uVs 11:31:59 Integrated Voltage Measurement... 11:32:08 Voltage Offset Correction: v_off_ini = 247.138 uV, v_off_fin = 246.085 uV 11:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.807 uVs 11:32:08 Integrated Voltage Measurement... 11:32:17 Voltage Offset Correction: v_off_ini = 241.824 uV, v_off_fin = 252.251 uV 11:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.550 uVs 11:32:19 I2Y Average and RMS of Measurements VT = -325.058 +- 0.653 uVs I2Y = -29.905 +- 0.060 uTm^2 11:32:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:32:28 Integrated Voltage Measurement... 11:32:37 Voltage Offset Correction: v_off_ini = 274.118 uV, v_off_fin = 269.245 uV 11:32:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.678 uVs 11:32:37 Integrated Voltage Measurement... 11:32:46 Voltage Offset Correction: v_off_ini = 270.679 uV, v_off_fin = 266.625 uV 11:32:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.284 uVs 11:32:46 Integrated Voltage Measurement... 11:32:55 Voltage Offset Correction: v_off_ini = 258.777 uV, v_off_fin = 260.079 uV 11:32:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.220 uVs 11:32:55 Integrated Voltage Measurement... 11:33:04 Voltage Offset Correction: v_off_ini = 263.456 uV, v_off_fin = 268.331 uV 11:33:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.998 uVs 11:33:04 Integrated Voltage Measurement... 11:33:13 Voltage Offset Correction: v_off_ini = 265.178 uV, v_off_fin = 257.228 uV 11:33:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.685 uVs 11:33:13 Integrated Voltage Measurement... 11:33:22 Voltage Offset Correction: v_off_ini = 267.253 uV, v_off_fin = 263.690 uV 11:33:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.146 uVs 11:33:26 I1X Average and RMS of Measurements VT = -64.669 +- 6.502 uVs I1X = 12.934 +- 1.301 uTm 11:33:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:33:33 Integrated Voltage Measurement... 11:33:42 Voltage Offset Correction: v_off_ini = 267.415 uV, v_off_fin = 254.225 uV 11:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.637 uVs 11:33:42 Integrated Voltage Measurement... 11:33:51 Voltage Offset Correction: v_off_ini = 278.992 uV, v_off_fin = 280.451 uV 11:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 252.421 uVs 11:33:51 Integrated Voltage Measurement... 11:34:00 Voltage Offset Correction: v_off_ini = 272.215 uV, v_off_fin = 260.184 uV 11:34:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.513 uVs 11:34:00 Integrated Voltage Measurement... 11:34:09 Voltage Offset Correction: v_off_ini = 255.877 uV, v_off_fin = 265.875 uV 11:34:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.015 uVs 11:34:09 Integrated Voltage Measurement... 11:34:18 Voltage Offset Correction: v_off_ini = 254.089 uV, v_off_fin = 258.549 uV 11:34:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.143 uVs 11:34:18 Integrated Voltage Measurement... 11:34:27 Voltage Offset Correction: v_off_ini = 275.058 uV, v_off_fin = 279.688 uV 11:34:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.670 uVs 11:34:31 I1Y Average and RMS of Measurements VT = -253.067 +- 2.449 uVs I1Y = -50.614 +- 0.491 uTm 11:34:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:34:39 Integrated Voltage Measurement... 11:34:48 Voltage Offset Correction: v_off_ini = 256.034 uV, v_off_fin = 246.991 uV 11:34:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.080 uVs 11:34:48 Integrated Voltage Measurement... 11:34:57 Voltage Offset Correction: v_off_ini = 256.451 uV, v_off_fin = 269.437 uV 11:34:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.060 uVs 11:34:57 Integrated Voltage Measurement... 11:35:06 Voltage Offset Correction: v_off_ini = 264.709 uV, v_off_fin = 256.216 uV 11:35:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.112 uVs 11:35:06 Integrated Voltage Measurement... 11:35:15 Voltage Offset Correction: v_off_ini = 268.109 uV, v_off_fin = 277.900 uV 11:35:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.368 uVs 11:35:15 Integrated Voltage Measurement... 11:35:24 Voltage Offset Correction: v_off_ini = 283.537 uV, v_off_fin = 274.694 uV 11:35:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.140 uVs 11:35:24 Integrated Voltage Measurement... 11:35:33 Voltage Offset Correction: v_off_ini = 272.704 uV, v_off_fin = 281.512 uV 11:35:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.895 uVs 11:35:36 I2X Average and RMS of Measurements VT = -104.943 +- 6.322 uVs I2X = 9.655 +- 0.582 uTm^2 11:35:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:35:43 Integrated Voltage Measurement... 11:35:52 Voltage Offset Correction: v_off_ini = 265.143 uV, v_off_fin = 270.735 uV 11:35:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.112 uVs 11:35:52 Integrated Voltage Measurement... 11:36:01 Voltage Offset Correction: v_off_ini = 278.456 uV, v_off_fin = 261.615 uV 11:36:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.053 uVs 11:36:02 Integrated Voltage Measurement... 11:36:10 Voltage Offset Correction: v_off_ini = 253.674 uV, v_off_fin = 262.931 uV 11:36:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.033 uVs 11:36:11 Integrated Voltage Measurement... 11:36:20 Voltage Offset Correction: v_off_ini = 245.334 uV, v_off_fin = 253.149 uV 11:36:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.502 uVs 11:36:20 Integrated Voltage Measurement... 11:36:29 Voltage Offset Correction: v_off_ini = 255.296 uV, v_off_fin = 247.531 uV 11:36:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.974 uVs 11:36:29 Integrated Voltage Measurement... 11:36:38 Voltage Offset Correction: v_off_ini = 253.478 uV, v_off_fin = 248.786 uV 11:36:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.160 uVs 11:36:40 I2Y Average and RMS of Measurements VT = -308.972 +- 7.509 uVs I2Y = -28.425 +- 0.691 uTm^2 11:36:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:49 Integrated Voltage Measurement... 11:36:58 Voltage Offset Correction: v_off_ini = 245.663 uV, v_off_fin = 253.687 uV 11:36:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.449 uVs 11:36:58 Integrated Voltage Measurement... 11:37:07 Voltage Offset Correction: v_off_ini = 257.996 uV, v_off_fin = 262.226 uV 11:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.241 uVs 11:37:07 Integrated Voltage Measurement... 11:37:16 Voltage Offset Correction: v_off_ini = 266.375 uV, v_off_fin = 257.088 uV 11:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.451 uVs 11:37:16 Integrated Voltage Measurement... 11:37:25 Voltage Offset Correction: v_off_ini = 247.993 uV, v_off_fin = 259.353 uV 11:37:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.377 uVs 11:37:25 Integrated Voltage Measurement... 11:37:34 Voltage Offset Correction: v_off_ini = 256.912 uV, v_off_fin = 245.966 uV 11:37:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.130 uVs 11:37:34 Integrated Voltage Measurement... 11:37:43 Voltage Offset Correction: v_off_ini = 257.990 uV, v_off_fin = 265.760 uV 11:37:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.307 uVs 11:37:47 I1X Average and RMS of Measurements VT = -73.993 +- 13.669 uVs I1X = 14.799 +- 2.734 uTm 11:37:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:54 Integrated Voltage Measurement... 11:38:03 Voltage Offset Correction: v_off_ini = 278.350 uV, v_off_fin = 256.917 uV 11:38:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.438 uVs 11:38:03 Integrated Voltage Measurement... 11:38:12 Voltage Offset Correction: v_off_ini = 271.380 uV, v_off_fin = 287.020 uV 11:38:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.152 uVs 11:38:12 Integrated Voltage Measurement... 11:38:21 Voltage Offset Correction: v_off_ini = 268.053 uV, v_off_fin = 257.995 uV 11:38:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.913 uVs 11:38:21 Integrated Voltage Measurement... 11:38:30 Voltage Offset Correction: v_off_ini = 271.275 uV, v_off_fin = 282.314 uV 11:38:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.856 uVs 11:38:30 Integrated Voltage Measurement... 11:38:39 Voltage Offset Correction: v_off_ini = 250.884 uV, v_off_fin = 242.152 uV 11:38:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.763 uVs 11:38:39 Integrated Voltage Measurement... 11:38:48 Voltage Offset Correction: v_off_ini = 244.735 uV, v_off_fin = 261.659 uV 11:38:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.987 uVs 11:38:52 I1Y Average and RMS of Measurements VT = -247.685 +- 4.844 uVs I1Y = -49.537 +- 0.969 uTm 11:38:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:00 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 264.130 uV, v_off_fin = 253.945 uV 11:39:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.976 uVs 11:39:09 Integrated Voltage Measurement... 11:39:18 Voltage Offset Correction: v_off_ini = 248.772 uV, v_off_fin = 267.418 uV 11:39:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.122 uVs 11:39:18 Integrated Voltage Measurement... 11:39:27 Voltage Offset Correction: v_off_ini = 269.886 uV, v_off_fin = 254.434 uV 11:39:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.474 uVs 11:39:27 Integrated Voltage Measurement... 11:39:36 Voltage Offset Correction: v_off_ini = 256.035 uV, v_off_fin = 263.688 uV 11:39:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.812 uVs 11:39:36 Integrated Voltage Measurement... 11:39:45 Voltage Offset Correction: v_off_ini = 255.386 uV, v_off_fin = 258.645 uV 11:39:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.960 uVs 11:39:45 Integrated Voltage Measurement... 11:39:54 Voltage Offset Correction: v_off_ini = 259.796 uV, v_off_fin = 278.588 uV 11:39:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.083 uVs 11:39:57 I2X Average and RMS of Measurements VT = -95.904 +- 8.657 uVs I2X = 8.823 +- 0.796 uTm^2 11:40:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:04 Integrated Voltage Measurement... 11:40:13 Voltage Offset Correction: v_off_ini = 256.348 uV, v_off_fin = 260.113 uV 11:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.060 uVs 11:40:13 Integrated Voltage Measurement... 11:40:22 Voltage Offset Correction: v_off_ini = 252.099 uV, v_off_fin = 254.743 uV 11:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.209 uVs 11:40:22 Integrated Voltage Measurement... 11:40:31 Voltage Offset Correction: v_off_ini = 256.319 uV, v_off_fin = 260.229 uV 11:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.209 uVs 11:40:31 Integrated Voltage Measurement... 11:40:40 Voltage Offset Correction: v_off_ini = 260.470 uV, v_off_fin = 240.994 uV 11:40:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.652 uVs 11:40:40 Integrated Voltage Measurement... 11:40:49 Voltage Offset Correction: v_off_ini = 239.848 uV, v_off_fin = 253.165 uV 11:40:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -294.420 uVs 11:40:49 Integrated Voltage Measurement... 11:40:58 Voltage Offset Correction: v_off_ini = 253.337 uV, v_off_fin = 245.484 uV 11:40:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.162 uVs 11:41:01 I2Y Average and RMS of Measurements VT = -303.952 +- 9.491 uVs I2Y = -27.964 +- 0.873 uTm^2 11:41:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:41:10 Integrated Voltage Measurement... 11:41:19 Voltage Offset Correction: v_off_ini = 226.463 uV, v_off_fin = 238.115 uV 11:41:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.870 uVs 11:41:19 Integrated Voltage Measurement... 11:41:28 Voltage Offset Correction: v_off_ini = 249.368 uV, v_off_fin = 251.102 uV 11:41:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.231 uVs 11:41:28 Integrated Voltage Measurement... 11:41:37 Voltage Offset Correction: v_off_ini = 238.430 uV, v_off_fin = 234.842 uV 11:41:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.774 uVs 11:41:37 Integrated Voltage Measurement... 11:41:46 Voltage Offset Correction: v_off_ini = 235.798 uV, v_off_fin = 253.140 uV 11:41:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.462 uVs 11:41:46 Integrated Voltage Measurement... 11:41:55 Voltage Offset Correction: v_off_ini = 245.416 uV, v_off_fin = 231.381 uV 11:41:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.169 uVs 11:41:55 Integrated Voltage Measurement... 11:42:04 Voltage Offset Correction: v_off_ini = 246.099 uV, v_off_fin = 244.091 uV 11:42:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.110 uVs 11:42:08 I1X Average and RMS of Measurements VT = -62.436 +- 1.004 uVs I1X = 12.487 +- 0.201 uTm 11:42:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:42:15 Integrated Voltage Measurement... 11:42:24 Voltage Offset Correction: v_off_ini = 224.729 uV, v_off_fin = 226.481 uV 11:42:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.069 uVs 11:42:24 Integrated Voltage Measurement... 11:42:33 Voltage Offset Correction: v_off_ini = 234.752 uV, v_off_fin = 239.419 uV 11:42:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.101 uVs 11:42:33 Integrated Voltage Measurement... 11:42:42 Voltage Offset Correction: v_off_ini = 222.964 uV, v_off_fin = 220.806 uV 11:42:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.747 uVs 11:42:42 Integrated Voltage Measurement... 11:42:51 Voltage Offset Correction: v_off_ini = 239.295 uV, v_off_fin = 252.746 uV 11:42:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.383 uVs 11:42:51 Integrated Voltage Measurement... 11:43:00 Voltage Offset Correction: v_off_ini = 243.025 uV, v_off_fin = 237.695 uV 11:43:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.238 uVs 11:43:00 Integrated Voltage Measurement... 11:43:09 Voltage Offset Correction: v_off_ini = 248.909 uV, v_off_fin = 259.603 uV 11:43:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.667 uVs 11:43:13 I1Y Average and RMS of Measurements VT = -247.034 +- 2.802 uVs I1Y = -49.407 +- 0.560 uTm 11:43:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:43:21 Integrated Voltage Measurement... 11:43:30 Voltage Offset Correction: v_off_ini = 233.835 uV, v_off_fin = 230.250 uV 11:43:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.258 uVs 11:43:30 Integrated Voltage Measurement... 11:43:39 Voltage Offset Correction: v_off_ini = 242.745 uV, v_off_fin = 253.557 uV 11:43:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.106 uVs 11:43:39 Integrated Voltage Measurement... 11:43:48 Voltage Offset Correction: v_off_ini = 236.693 uV, v_off_fin = 231.202 uV 11:43:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.802 uVs 11:43:48 Integrated Voltage Measurement... 11:43:57 Voltage Offset Correction: v_off_ini = 249.027 uV, v_off_fin = 250.714 uV 11:43:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.645 uVs 11:43:57 Integrated Voltage Measurement... 11:44:06 Voltage Offset Correction: v_off_ini = 235.606 uV, v_off_fin = 225.513 uV 11:44:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.702 uVs 11:44:06 Integrated Voltage Measurement... 11:44:15 Voltage Offset Correction: v_off_ini = 231.829 uV, v_off_fin = 233.295 uV 11:44:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.883 uVs 11:44:17 I2X Average and RMS of Measurements VT = -87.399 +- 6.393 uVs I2X = 8.041 +- 0.588 uTm^2 11:44:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:44:25 Integrated Voltage Measurement... 11:44:34 Voltage Offset Correction: v_off_ini = 223.494 uV, v_off_fin = 229.909 uV 11:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.630 uVs 11:44:34 Integrated Voltage Measurement... 11:44:43 Voltage Offset Correction: v_off_ini = 224.705 uV, v_off_fin = 233.520 uV 11:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.857 uVs 11:44:43 Integrated Voltage Measurement... 11:44:52 Voltage Offset Correction: v_off_ini = 232.315 uV, v_off_fin = 232.040 uV 11:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.783 uVs 11:44:52 Integrated Voltage Measurement... 11:45:01 Voltage Offset Correction: v_off_ini = 239.731 uV, v_off_fin = 234.681 uV 11:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.401 uVs 11:45:01 Integrated Voltage Measurement... 11:45:10 Voltage Offset Correction: v_off_ini = 226.822 uV, v_off_fin = 239.592 uV 11:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.744 uVs 11:45:10 Integrated Voltage Measurement... 11:45:19 Voltage Offset Correction: v_off_ini = 230.114 uV, v_off_fin = 225.724 uV 11:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.131 uVs 11:45:22 I2Y Average and RMS of Measurements VT = -308.424 +- 3.222 uVs I2Y = -28.375 +- 0.296 uTm^2 11:45:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:45:31 Integrated Voltage Measurement... 11:45:40 Voltage Offset Correction: v_off_ini = 228.907 uV, v_off_fin = 219.449 uV 11:45:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -60.459 uVs 11:45:40 Integrated Voltage Measurement... 11:45:49 Voltage Offset Correction: v_off_ini = 223.377 uV, v_off_fin = 226.150 uV 11:45:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.914 uVs 11:45:49 Integrated Voltage Measurement... 11:45:58 Voltage Offset Correction: v_off_ini = 233.868 uV, v_off_fin = 233.034 uV 11:45:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.580 uVs 11:45:58 Integrated Voltage Measurement... 11:46:07 Voltage Offset Correction: v_off_ini = 227.937 uV, v_off_fin = 219.743 uV 11:46:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.149 uVs 11:46:07 Integrated Voltage Measurement... 11:46:16 Voltage Offset Correction: v_off_ini = 221.382 uV, v_off_fin = 219.711 uV 11:46:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.324 uVs 11:46:16 Integrated Voltage Measurement... 11:46:25 Voltage Offset Correction: v_off_ini = 227.333 uV, v_off_fin = 236.923 uV 11:46:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.925 uVs 11:46:29 I1X Average and RMS of Measurements VT = -66.725 +- 3.995 uVs I1X = 13.345 +- 0.799 uTm 11:46:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:46:36 Integrated Voltage Measurement... 11:46:45 Voltage Offset Correction: v_off_ini = 225.396 uV, v_off_fin = 222.261 uV 11:46:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.752 uVs 11:46:45 Integrated Voltage Measurement... 11:46:54 Voltage Offset Correction: v_off_ini = 215.273 uV, v_off_fin = 234.185 uV 11:46:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.812 uVs 11:46:54 Integrated Voltage Measurement... 11:47:03 Voltage Offset Correction: v_off_ini = 218.940 uV, v_off_fin = 223.145 uV 11:47:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.347 uVs 11:47:03 Integrated Voltage Measurement... 11:47:12 Voltage Offset Correction: v_off_ini = 230.536 uV, v_off_fin = 235.721 uV 11:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.228 uVs 11:47:12 Integrated Voltage Measurement... 11:47:21 Voltage Offset Correction: v_off_ini = 225.951 uV, v_off_fin = 218.166 uV 11:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.090 uVs 11:47:21 Integrated Voltage Measurement... 11:47:30 Voltage Offset Correction: v_off_ini = 227.435 uV, v_off_fin = 238.773 uV 11:47:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.812 uVs 11:47:34 I1Y Average and RMS of Measurements VT = -249.173 +- 6.310 uVs I1Y = -49.835 +- 1.262 uTm 11:47:39 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:47:42 Integrated Voltage Measurement... 11:47:51 Voltage Offset Correction: v_off_ini = 222.887 uV, v_off_fin = 216.826 uV 11:47:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.104 uVs 11:47:51 Integrated Voltage Measurement... 11:48:00 Voltage Offset Correction: v_off_ini = 229.314 uV, v_off_fin = 237.469 uV 11:48:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.107 uVs 11:48:00 Integrated Voltage Measurement... 11:48:09 Voltage Offset Correction: v_off_ini = 243.395 uV, v_off_fin = 223.754 uV 11:48:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.430 uVs 11:48:09 Integrated Voltage Measurement... 11:48:18 Voltage Offset Correction: v_off_ini = 216.841 uV, v_off_fin = 208.825 uV 11:48:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.487 uVs 11:48:18 Integrated Voltage Measurement... 11:48:27 Voltage Offset Correction: v_off_ini = 211.498 uV, v_off_fin = 213.808 uV 11:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.267 uVs 11:48:27 Integrated Voltage Measurement... 11:48:36 Voltage Offset Correction: v_off_ini = 210.241 uV, v_off_fin = 231.345 uV 11:48:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.720 uVs 11:48:38 I2X Average and RMS of Measurements VT = -79.186 +- 2.612 uVs I2X = 7.285 +- 0.240 uTm^2 11:48:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:48:46 Integrated Voltage Measurement... 11:48:55 Voltage Offset Correction: v_off_ini = 218.513 uV, v_off_fin = 217.218 uV 11:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.358 uVs 11:48:55 Integrated Voltage Measurement... 11:49:04 Voltage Offset Correction: v_off_ini = 195.578 uV, v_off_fin = 198.224 uV 11:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.217 uVs 11:49:04 Integrated Voltage Measurement... 11:49:13 Voltage Offset Correction: v_off_ini = 208.804 uV, v_off_fin = 187.763 uV 11:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.136 uVs 11:49:13 Integrated Voltage Measurement... 11:49:22 Voltage Offset Correction: v_off_ini = 193.722 uV, v_off_fin = 207.352 uV 11:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.855 uVs 11:49:22 Integrated Voltage Measurement... 11:49:31 Voltage Offset Correction: v_off_ini = 202.843 uV, v_off_fin = 197.043 uV 11:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.984 uVs 11:49:31 Integrated Voltage Measurement... 11:49:40 Voltage Offset Correction: v_off_ini = 209.546 uV, v_off_fin = 190.382 uV 11:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.379 uVs 11:49:42 I2Y Average and RMS of Measurements VT = -300.155 +- 5.111 uVs I2Y = -27.614 +- 0.470 uTm^2 11:49:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:49:54 Integrated Voltage Measurement... 11:50:03 Voltage Offset Correction: v_off_ini = 189.996 uV, v_off_fin = 195.421 uV 11:50:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -38.815 uVs 11:50:03 Integrated Voltage Measurement... 11:50:12 Voltage Offset Correction: v_off_ini = 191.539 uV, v_off_fin = 197.418 uV 11:50:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.414 uVs 11:50:13 Integrated Voltage Measurement... 11:50:21 Voltage Offset Correction: v_off_ini = 193.051 uV, v_off_fin = 192.209 uV 11:50:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.480 uVs 11:50:22 Integrated Voltage Measurement... 11:50:30 Voltage Offset Correction: v_off_ini = 193.013 uV, v_off_fin = 204.093 uV 11:50:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.274 uVs 11:50:31 Integrated Voltage Measurement... 11:50:39 Voltage Offset Correction: v_off_ini = 193.736 uV, v_off_fin = 187.937 uV 11:50:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.174 uVs 11:50:40 Integrated Voltage Measurement... 11:50:49 Voltage Offset Correction: v_off_ini = 193.030 uV, v_off_fin = 186.577 uV 11:50:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.694 uVs 11:50:53 I1X Average and RMS of Measurements VT = -52.809 +- 10.751 uVs I1X = 10.562 +- 2.150 uTm 11:50:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:51:00 Integrated Voltage Measurement... 11:51:08 Voltage Offset Correction: v_off_ini = 172.853 uV, v_off_fin = 177.177 uV 11:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.476 uVs 11:51:09 Integrated Voltage Measurement... 11:51:17 Voltage Offset Correction: v_off_ini = 174.933 uV, v_off_fin = 192.424 uV 11:51:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.887 uVs 11:51:18 Integrated Voltage Measurement... 11:51:26 Voltage Offset Correction: v_off_ini = 166.643 uV, v_off_fin = 164.578 uV 11:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.486 uVs 11:51:27 Integrated Voltage Measurement... 11:51:35 Voltage Offset Correction: v_off_ini = 177.183 uV, v_off_fin = 181.464 uV 11:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.355 uVs 11:51:36 Integrated Voltage Measurement... 11:51:44 Voltage Offset Correction: v_off_ini = 176.963 uV, v_off_fin = 163.483 uV 11:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.826 uVs 11:51:45 Integrated Voltage Measurement... 11:51:53 Voltage Offset Correction: v_off_ini = 179.921 uV, v_off_fin = 192.344 uV 11:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.020 uVs 11:51:58 I1Y Average and RMS of Measurements VT = -252.175 +- 1.671 uVs I1Y = -50.435 +- 0.334 uTm 11:52:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:52:03 Integrated Voltage Measurement... 11:52:12 Voltage Offset Correction: v_off_ini = 174.993 uV, v_off_fin = 168.848 uV 11:52:12 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -77.546 uVs 11:52:12 Integrated Voltage Measurement... 11:52:21 Voltage Offset Correction: v_off_ini = 163.563 uV, v_off_fin = 174.620 uV 11:52:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.297 uVs 11:52:21 Integrated Voltage Measurement... 11:52:30 Voltage Offset Correction: v_off_ini = 165.949 uV, v_off_fin = 177.356 uV 11:52:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.127 uVs 11:52:30 Integrated Voltage Measurement... 11:52:39 Voltage Offset Correction: v_off_ini = 184.331 uV, v_off_fin = 190.445 uV 11:52:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.587 uVs 11:52:39 Integrated Voltage Measurement... 11:52:48 Voltage Offset Correction: v_off_ini = 190.686 uV, v_off_fin = 158.787 uV 11:52:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.530 uVs 11:52:48 Integrated Voltage Measurement... 11:52:57 Voltage Offset Correction: v_off_ini = 168.737 uV, v_off_fin = 173.546 uV 11:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.722 uVs 11:52:59 I2X Average and RMS of Measurements VT = -75.635 +- 6.661 uVs I2X = 6.959 +- 0.613 uTm^2 11:53:02 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:53:05 Integrated Voltage Measurement... 11:53:13 Voltage Offset Correction: v_off_ini = 176.517 uV, v_off_fin = 165.862 uV 11:53:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.833 uVs 11:53:14 Integrated Voltage Measurement... 11:53:23 Voltage Offset Correction: v_off_ini = 175.062 uV, v_off_fin = 169.543 uV 11:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.503 uVs 11:53:23 Integrated Voltage Measurement... 11:53:32 Voltage Offset Correction: v_off_ini = 172.663 uV, v_off_fin = 175.179 uV 11:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.707 uVs 11:53:32 Integrated Voltage Measurement... 11:53:41 Voltage Offset Correction: v_off_ini = 180.647 uV, v_off_fin = 176.205 uV 11:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.180 uVs 11:53:41 Integrated Voltage Measurement... 11:53:50 Voltage Offset Correction: v_off_ini = 177.813 uV, v_off_fin = 168.975 uV 11:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.612 uVs 11:53:50 Integrated Voltage Measurement... 11:53:59 Voltage Offset Correction: v_off_ini = 167.972 uV, v_off_fin = 180.842 uV 11:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.009 uVs 11:54:01 I2Y Average and RMS of Measurements VT = -319.807 +- 8.536 uVs I2Y = -29.422 +- 0.785 uTm^2 11:54:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:54:09 Integrated Voltage Measurement... 11:54:18 Voltage Offset Correction: v_off_ini = 173.965 uV, v_off_fin = 158.157 uV 11:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.746 uVs 11:54:18 Integrated Voltage Measurement... 11:54:27 Voltage Offset Correction: v_off_ini = 168.712 uV, v_off_fin = 172.406 uV 11:54:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.550 uVs 11:54:28 Integrated Voltage Measurement... 11:54:36 Voltage Offset Correction: v_off_ini = 168.083 uV, v_off_fin = 176.626 uV 11:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.815 uVs 11:54:37 Integrated Voltage Measurement... 11:54:45 Voltage Offset Correction: v_off_ini = 172.318 uV, v_off_fin = 163.801 uV 11:54:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.267 uVs 11:54:46 Integrated Voltage Measurement... 11:54:55 Voltage Offset Correction: v_off_ini = 159.958 uV, v_off_fin = 151.836 uV 11:54:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.534 uVs 11:54:55 Integrated Voltage Measurement... 11:55:04 Voltage Offset Correction: v_off_ini = 174.562 uV, v_off_fin = 174.808 uV 11:55:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.634 uVs 11:55:08 I1X Average and RMS of Measurements VT = -65.924 +- 1.174 uVs I1X = 13.185 +- 0.235 uTm 11:55:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:55:15 Integrated Voltage Measurement... 11:55:23 Voltage Offset Correction: v_off_ini = 137.951 uV, v_off_fin = 143.892 uV 11:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.935 uVs 11:55:24 Integrated Voltage Measurement... 11:55:32 Voltage Offset Correction: v_off_ini = 153.860 uV, v_off_fin = 186.519 uV 11:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.491 uVs 11:55:33 Integrated Voltage Measurement... 11:55:42 Voltage Offset Correction: v_off_ini = 164.936 uV, v_off_fin = 146.320 uV 11:55:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.753 uVs 11:55:42 Integrated Voltage Measurement... 11:55:50 Voltage Offset Correction: v_off_ini = 148.724 uV, v_off_fin = 162.301 uV 11:55:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.987 uVs 11:55:51 Integrated Voltage Measurement... 11:55:59 Voltage Offset Correction: v_off_ini = 153.763 uV, v_off_fin = 142.503 uV 11:56:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.882 uVs 11:56:00 Integrated Voltage Measurement... 11:56:08 Voltage Offset Correction: v_off_ini = 147.072 uV, v_off_fin = 166.295 uV 11:56:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.815 uVs 11:56:13 I1Y Average and RMS of Measurements VT = -244.310 +- 4.870 uVs I1Y = -48.862 +- 0.974 uTm 11:56:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:56:18 Integrated Voltage Measurement... 11:56:27 Voltage Offset Correction: v_off_ini = 156.715 uV, v_off_fin = 139.133 uV 11:56:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.827 uVs 11:56:27 Integrated Voltage Measurement... 11:56:36 Voltage Offset Correction: v_off_ini = 152.099 uV, v_off_fin = 164.643 uV 11:56:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.790 uVs 11:56:36 Integrated Voltage Measurement... 11:56:45 Voltage Offset Correction: v_off_ini = 155.385 uV, v_off_fin = 143.025 uV 11:56:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.679 uVs 11:56:45 Integrated Voltage Measurement... 11:56:54 Voltage Offset Correction: v_off_ini = 137.112 uV, v_off_fin = 159.366 uV 11:56:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.316 uVs 11:56:54 Integrated Voltage Measurement... 11:57:03 Voltage Offset Correction: v_off_ini = 138.608 uV, v_off_fin = 137.467 uV 11:57:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.225 uVs 11:57:03 Integrated Voltage Measurement... 11:57:12 Voltage Offset Correction: v_off_ini = 157.967 uV, v_off_fin = 162.554 uV 11:57:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.534 uVs 11:57:14 I2X Average and RMS of Measurements VT = -94.562 +- 1.765 uVs I2X = 8.700 +- 0.162 uTm^2 11:57:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:57:20 Integrated Voltage Measurement... 11:57:29 Voltage Offset Correction: v_off_ini = 161.770 uV, v_off_fin = 153.865 uV 11:57:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.228 uVs 11:57:29 Integrated Voltage Measurement... 11:57:38 Voltage Offset Correction: v_off_ini = 161.341 uV, v_off_fin = 154.620 uV 11:57:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.526 uVs 11:57:38 Integrated Voltage Measurement... 11:57:47 Voltage Offset Correction: v_off_ini = 156.573 uV, v_off_fin = 155.739 uV 11:57:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.544 uVs 11:57:47 Integrated Voltage Measurement... 11:57:56 Voltage Offset Correction: v_off_ini = 159.790 uV, v_off_fin = 153.799 uV 11:57:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.145 uVs 11:57:56 Integrated Voltage Measurement... 11:58:05 Voltage Offset Correction: v_off_ini = 151.993 uV, v_off_fin = 155.050 uV 11:58:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.993 uVs 11:58:05 Integrated Voltage Measurement... 11:58:14 Voltage Offset Correction: v_off_ini = 158.399 uV, v_off_fin = 162.447 uV 11:58:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.237 uVs 11:58:16 I2Y Average and RMS of Measurements VT = -311.612 +- 9.553 uVs I2Y = -28.668 +- 0.879 uTm^2 11:58:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:25 Integrated Voltage Measurement... 11:58:34 Voltage Offset Correction: v_off_ini = 189.723 uV, v_off_fin = 170.560 uV 11:58:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.445 uVs 11:58:34 Integrated Voltage Measurement... 11:58:43 Voltage Offset Correction: v_off_ini = 166.950 uV, v_off_fin = 153.367 uV 11:58:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.424 uVs 11:58:43 Integrated Voltage Measurement... 11:58:52 Voltage Offset Correction: v_off_ini = 156.587 uV, v_off_fin = 157.311 uV 11:58:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.861 uVs 11:58:52 Integrated Voltage Measurement... 11:59:01 Voltage Offset Correction: v_off_ini = 172.148 uV, v_off_fin = 178.734 uV 11:59:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.686 uVs 11:59:01 Integrated Voltage Measurement... 11:59:10 Voltage Offset Correction: v_off_ini = 170.077 uV, v_off_fin = 168.844 uV 11:59:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.039 uVs 11:59:10 Integrated Voltage Measurement... 11:59:19 Voltage Offset Correction: v_off_ini = 174.994 uV, v_off_fin = 171.452 uV 11:59:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.608 uVs 11:59:23 I1X Average and RMS of Measurements VT = -76.010 +- 5.690 uVs I1X = 15.202 +- 1.138 uTm 11:59:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:30 Integrated Voltage Measurement... 11:59:39 Voltage Offset Correction: v_off_ini = 162.290 uV, v_off_fin = 150.868 uV 11:59:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.275 uVs 11:59:39 Integrated Voltage Measurement... 11:59:48 Voltage Offset Correction: v_off_ini = 168.592 uV, v_off_fin = 178.584 uV 11:59:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.773 uVs 11:59:48 Integrated Voltage Measurement... 11:59:57 Voltage Offset Correction: v_off_ini = 176.905 uV, v_off_fin = 166.404 uV 11:59:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.794 uVs 11:59:57 Integrated Voltage Measurement... 12:00:06 Voltage Offset Correction: v_off_ini = 184.660 uV, v_off_fin = 200.871 uV 12:00:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.059 uVs 12:00:06 Integrated Voltage Measurement... 12:00:15 Voltage Offset Correction: v_off_ini = 187.810 uV, v_off_fin = 180.898 uV 12:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.482 uVs 12:00:15 Integrated Voltage Measurement... 12:00:24 Voltage Offset Correction: v_off_ini = 178.942 uV, v_off_fin = 197.766 uV 12:00:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.825 uVs 12:00:28 I1Y Average and RMS of Measurements VT = -245.701 +- 4.444 uVs I1Y = -49.140 +- 0.889 uTm 12:00:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:33 Integrated Voltage Measurement... 12:00:42 Voltage Offset Correction: v_off_ini = 185.678 uV, v_off_fin = 179.057 uV 12:00:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.815 uVs 12:00:42 Integrated Voltage Measurement... 12:00:51 Voltage Offset Correction: v_off_ini = 194.075 uV, v_off_fin = 202.779 uV 12:00:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.541 uVs 12:00:51 Integrated Voltage Measurement... 12:01:00 Voltage Offset Correction: v_off_ini = 178.083 uV, v_off_fin = 179.312 uV 12:01:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.793 uVs 12:01:00 Integrated Voltage Measurement... 12:01:09 Voltage Offset Correction: v_off_ini = 183.102 uV, v_off_fin = 201.177 uV 12:01:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.473 uVs 12:01:09 Integrated Voltage Measurement... 12:01:18 Voltage Offset Correction: v_off_ini = 195.671 uV, v_off_fin = 180.451 uV 12:01:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.975 uVs 12:01:18 Integrated Voltage Measurement... 12:01:27 Voltage Offset Correction: v_off_ini = 181.691 uV, v_off_fin = 181.882 uV 12:01:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.744 uVs 12:01:29 I2X Average and RMS of Measurements VT = -92.057 +- 3.903 uVs I2X = 8.469 +- 0.359 uTm^2 12:01:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:35 Integrated Voltage Measurement... 12:01:44 Voltage Offset Correction: v_off_ini = 182.180 uV, v_off_fin = 167.735 uV 12:01:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.580 uVs 12:01:44 Integrated Voltage Measurement... 12:01:53 Voltage Offset Correction: v_off_ini = 176.682 uV, v_off_fin = 175.516 uV 12:01:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.871 uVs 12:01:53 Integrated Voltage Measurement... 12:02:02 Voltage Offset Correction: v_off_ini = 181.571 uV, v_off_fin = 186.958 uV 12:02:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.572 uVs 12:02:02 Integrated Voltage Measurement... 12:02:11 Voltage Offset Correction: v_off_ini = 200.370 uV, v_off_fin = 190.884 uV 12:02:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.852 uVs 12:02:11 Integrated Voltage Measurement... 12:02:20 Voltage Offset Correction: v_off_ini = 196.818 uV, v_off_fin = 176.116 uV 12:02:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.784 uVs 12:02:20 Integrated Voltage Measurement... 12:02:29 Voltage Offset Correction: v_off_ini = 176.436 uV, v_off_fin = 175.908 uV 12:02:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.025 uVs 12:02:31 I2Y Average and RMS of Measurements VT = -307.781 +- 12.827 uVs I2Y = -28.316 +- 1.180 uTm^2 12:02:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:02:40 Integrated Voltage Measurement... 12:02:48 Voltage Offset Correction: v_off_ini = 184.495 uV, v_off_fin = 168.167 uV 12:02:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -70.874 uVs 12:02:49 Integrated Voltage Measurement... 12:02:57 Voltage Offset Correction: v_off_ini = 178.895 uV, v_off_fin = 181.167 uV 12:02:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.041 uVs 12:02:58 Integrated Voltage Measurement... 12:03:07 Voltage Offset Correction: v_off_ini = 181.211 uV, v_off_fin = 178.566 uV 12:03:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.681 uVs 12:03:07 Integrated Voltage Measurement... 12:03:16 Voltage Offset Correction: v_off_ini = 173.767 uV, v_off_fin = 180.625 uV 12:03:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.224 uVs 12:03:16 Integrated Voltage Measurement... 12:03:25 Voltage Offset Correction: v_off_ini = 185.087 uV, v_off_fin = 176.433 uV 12:03:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.697 uVs 12:03:25 Integrated Voltage Measurement... 12:03:34 Voltage Offset Correction: v_off_ini = 187.838 uV, v_off_fin = 187.546 uV 12:03:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.831 uVs 12:03:38 I1X Average and RMS of Measurements VT = -68.891 +- 8.507 uVs I1X = 13.779 +- 1.702 uTm 12:03:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:03:45 Integrated Voltage Measurement... 12:03:54 Voltage Offset Correction: v_off_ini = 183.089 uV, v_off_fin = 172.381 uV 12:03:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.702 uVs 12:03:54 Integrated Voltage Measurement... 12:04:03 Voltage Offset Correction: v_off_ini = 194.162 uV, v_off_fin = 208.892 uV 12:04:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.426 uVs 12:04:03 Integrated Voltage Measurement... 12:04:12 Voltage Offset Correction: v_off_ini = 192.348 uV, v_off_fin = 178.137 uV 12:04:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.932 uVs 12:04:12 Integrated Voltage Measurement... 12:04:20 Voltage Offset Correction: v_off_ini = 184.374 uV, v_off_fin = 200.401 uV 12:04:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.729 uVs 12:04:21 Integrated Voltage Measurement... 12:04:30 Voltage Offset Correction: v_off_ini = 194.214 uV, v_off_fin = 181.954 uV 12:04:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.855 uVs 12:04:30 Integrated Voltage Measurement... 12:04:38 Voltage Offset Correction: v_off_ini = 186.939 uV, v_off_fin = 193.946 uV 12:04:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.592 uVs 12:04:43 I1Y Average and RMS of Measurements VT = -241.706 +- 9.033 uVs I1Y = -48.342 +- 1.806 uTm 12:04:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:04:48 Integrated Voltage Measurement... 12:04:57 Voltage Offset Correction: v_off_ini = 171.605 uV, v_off_fin = 170.945 uV 12:04:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.731 uVs 12:04:57 Integrated Voltage Measurement... 12:05:06 Voltage Offset Correction: v_off_ini = 181.423 uV, v_off_fin = 185.470 uV 12:05:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.531 uVs 12:05:06 Integrated Voltage Measurement... 12:05:15 Voltage Offset Correction: v_off_ini = 184.018 uV, v_off_fin = 179.672 uV 12:05:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.906 uVs 12:05:15 Integrated Voltage Measurement... 12:05:24 Voltage Offset Correction: v_off_ini = 182.048 uV, v_off_fin = 183.054 uV 12:05:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.440 uVs 12:05:24 Integrated Voltage Measurement... 12:05:33 Voltage Offset Correction: v_off_ini = 177.074 uV, v_off_fin = 170.731 uV 12:05:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.472 uVs 12:05:33 Integrated Voltage Measurement... 12:05:42 Voltage Offset Correction: v_off_ini = 166.675 uV, v_off_fin = 177.861 uV 12:05:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.095 uVs 12:05:44 I2X Average and RMS of Measurements VT = -91.696 +- 2.300 uVs I2X = 8.436 +- 0.212 uTm^2 12:05:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:05:50 Integrated Voltage Measurement... 12:05:59 Voltage Offset Correction: v_off_ini = 180.569 uV, v_off_fin = 183.695 uV 12:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.660 uVs 12:05:59 Integrated Voltage Measurement... 12:06:08 Voltage Offset Correction: v_off_ini = 190.389 uV, v_off_fin = 185.104 uV 12:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.427 uVs 12:06:08 Integrated Voltage Measurement... 12:06:17 Voltage Offset Correction: v_off_ini = 175.120 uV, v_off_fin = 190.439 uV 12:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.135 uVs 12:06:17 Integrated Voltage Measurement... 12:06:26 Voltage Offset Correction: v_off_ini = 182.071 uV, v_off_fin = 178.667 uV 12:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.802 uVs 12:06:26 Integrated Voltage Measurement... 12:06:35 Voltage Offset Correction: v_off_ini = 183.954 uV, v_off_fin = 185.640 uV 12:06:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.121 uVs 12:06:35 Integrated Voltage Measurement... 12:06:44 Voltage Offset Correction: v_off_ini = 188.136 uV, v_off_fin = 189.420 uV 12:06:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.938 uVs 12:06:46 I2Y Average and RMS of Measurements VT = -306.014 +- 9.577 uVs I2Y = -28.153 +- 0.881 uTm^2 12:06:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:06:55 Integrated Voltage Measurement... 12:07:03 Voltage Offset Correction: v_off_ini = 193.210 uV, v_off_fin = 187.687 uV 12:07:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -46.097 uVs 12:07:04 Integrated Voltage Measurement... 12:07:12 Voltage Offset Correction: v_off_ini = 210.673 uV, v_off_fin = 204.724 uV 12:07:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.897 uVs 12:07:13 Integrated Voltage Measurement... 12:07:22 Voltage Offset Correction: v_off_ini = 198.287 uV, v_off_fin = 190.520 uV 12:07:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.893 uVs 12:07:22 Integrated Voltage Measurement... 12:07:31 Voltage Offset Correction: v_off_ini = 199.605 uV, v_off_fin = 215.925 uV 12:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.718 uVs 12:07:31 Integrated Voltage Measurement... 12:07:40 Voltage Offset Correction: v_off_ini = 195.396 uV, v_off_fin = 183.912 uV 12:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.099 uVs 12:07:40 Integrated Voltage Measurement... 12:07:49 Voltage Offset Correction: v_off_ini = 198.478 uV, v_off_fin = 191.956 uV 12:07:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.374 uVs 12:07:53 I1X Average and RMS of Measurements VT = -55.513 +- 13.288 uVs I1X = 11.103 +- 2.657 uTm 12:07:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:08:00 Integrated Voltage Measurement... 12:08:09 Voltage Offset Correction: v_off_ini = 188.797 uV, v_off_fin = 186.345 uV 12:08:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.182 uVs 12:08:09 Integrated Voltage Measurement... 12:08:18 Voltage Offset Correction: v_off_ini = 180.814 uV, v_off_fin = 191.721 uV 12:08:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.882 uVs 12:08:18 Integrated Voltage Measurement... 12:08:27 Voltage Offset Correction: v_off_ini = 196.801 uV, v_off_fin = 183.171 uV 12:08:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.673 uVs 12:08:27 Integrated Voltage Measurement... 12:08:36 Voltage Offset Correction: v_off_ini = 185.584 uV, v_off_fin = 200.379 uV 12:08:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.998 uVs 12:08:36 Integrated Voltage Measurement... 12:08:45 Voltage Offset Correction: v_off_ini = 198.482 uV, v_off_fin = 181.972 uV 12:08:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -255.499 uVs 12:08:45 Integrated Voltage Measurement... 12:08:54 Voltage Offset Correction: v_off_ini = 193.723 uV, v_off_fin = 198.820 uV 12:08:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.726 uVs 12:08:58 I1Y Average and RMS of Measurements VT = -248.160 +- 3.106 uVs I1Y = -49.630 +- 0.622 uTm 12:09:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:09:03 Integrated Voltage Measurement... 12:09:12 Voltage Offset Correction: v_off_ini = 186.798 uV, v_off_fin = 184.109 uV 12:09:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -60.099 uVs 12:09:12 Integrated Voltage Measurement... 12:09:21 Voltage Offset Correction: v_off_ini = 199.399 uV, v_off_fin = 208.533 uV 12:09:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.923 uVs 12:09:21 Integrated Voltage Measurement... 12:09:30 Voltage Offset Correction: v_off_ini = 204.421 uV, v_off_fin = 193.644 uV 12:09:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.336 uVs 12:09:30 Integrated Voltage Measurement... 12:09:39 Voltage Offset Correction: v_off_ini = 199.631 uV, v_off_fin = 209.838 uV 12:09:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.753 uVs 12:09:39 Integrated Voltage Measurement... 12:09:48 Voltage Offset Correction: v_off_ini = 189.516 uV, v_off_fin = 177.625 uV 12:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.742 uVs 12:09:48 Integrated Voltage Measurement... 12:09:57 Voltage Offset Correction: v_off_ini = 193.264 uV, v_off_fin = 185.415 uV 12:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.790 uVs 12:10:00 I2X Average and RMS of Measurements VT = -87.107 +- 13.698 uVs I2X = 8.014 +- 1.260 uTm^2 12:10:02 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:10:05 Integrated Voltage Measurement... 12:10:14 Voltage Offset Correction: v_off_ini = 163.339 uV, v_off_fin = 181.830 uV 12:10:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.995 uVs 12:10:14 Integrated Voltage Measurement... 12:10:23 Voltage Offset Correction: v_off_ini = 188.263 uV, v_off_fin = 185.664 uV 12:10:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.445 uVs 12:10:23 Integrated Voltage Measurement... 12:10:32 Voltage Offset Correction: v_off_ini = 192.699 uV, v_off_fin = 194.056 uV 12:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.081 uVs 12:10:32 Integrated Voltage Measurement... 12:10:41 Voltage Offset Correction: v_off_ini = 182.428 uV, v_off_fin = 188.134 uV 12:10:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.337 uVs 12:10:41 Integrated Voltage Measurement... 12:10:50 Voltage Offset Correction: v_off_ini = 192.770 uV, v_off_fin = 188.597 uV 12:10:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.897 uVs 12:10:50 Integrated Voltage Measurement... 12:10:59 Voltage Offset Correction: v_off_ini = 197.090 uV, v_off_fin = 197.906 uV 12:10:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 298.819 uVs 12:11:01 I2Y Average and RMS of Measurements VT = -309.429 +- 2.353 uVs I2Y = -28.468 +- 0.216 uTm^2 12:11:18 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:11:23 Integrated Voltage Measurement... 12:11:32 Voltage Offset Correction: v_off_ini = 195.214 uV, v_off_fin = 188.554 uV 12:11:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.864 uVs 12:11:32 Integrated Voltage Measurement... 12:11:41 Voltage Offset Correction: v_off_ini = 196.390 uV, v_off_fin = 194.457 uV 12:11:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.247 uVs 12:11:41 Integrated Voltage Measurement... 12:11:50 Voltage Offset Correction: v_off_ini = 194.986 uV, v_off_fin = 188.448 uV 12:11:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.193 uVs 12:11:50 Integrated Voltage Measurement... 12:11:59 Voltage Offset Correction: v_off_ini = 198.431 uV, v_off_fin = 210.221 uV 12:11:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.176 uVs 12:11:59 Integrated Voltage Measurement... 12:12:08 Voltage Offset Correction: v_off_ini = 204.512 uV, v_off_fin = 187.912 uV 12:12:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.059 uVs 12:12:08 Integrated Voltage Measurement... 12:12:17 Voltage Offset Correction: v_off_ini = 194.097 uV, v_off_fin = 202.971 uV 12:12:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.521 uVs 12:12:21 I1X Average and RMS of Measurements VT = -78.677 +- 4.173 uVs I1X = 15.737 +- 0.836 uTm 12:12:23 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:12:28 Integrated Voltage Measurement... 12:12:37 Voltage Offset Correction: v_off_ini = 208.682 uV, v_off_fin = 191.230 uV 12:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.566 uVs 12:12:37 Integrated Voltage Measurement... 12:12:46 Voltage Offset Correction: v_off_ini = 218.767 uV, v_off_fin = 224.648 uV 12:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.429 uVs 12:12:46 Integrated Voltage Measurement... 12:12:55 Voltage Offset Correction: v_off_ini = 206.321 uV, v_off_fin = 182.336 uV 12:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.550 uVs 12:12:55 Integrated Voltage Measurement... 12:13:04 Voltage Offset Correction: v_off_ini = 200.289 uV, v_off_fin = 200.786 uV 12:13:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.713 uVs 12:13:04 Integrated Voltage Measurement... 12:13:13 Voltage Offset Correction: v_off_ini = 180.816 uV, v_off_fin = 182.019 uV 12:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.190 uVs 12:13:13 Integrated Voltage Measurement... 12:13:22 Voltage Offset Correction: v_off_ini = 201.458 uV, v_off_fin = 210.086 uV 12:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.640 uVs 12:13:26 I1Y Average and RMS of Measurements VT = -260.348 +- 5.064 uVs I1Y = -52.070 +- 1.013 uTm 12:13:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:13:34 Integrated Voltage Measurement... 12:13:43 Voltage Offset Correction: v_off_ini = 187.414 uV, v_off_fin = 187.183 uV 12:13:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.416 uVs 12:13:43 Integrated Voltage Measurement... 12:13:52 Voltage Offset Correction: v_off_ini = 171.405 uV, v_off_fin = 182.000 uV 12:13:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.457 uVs 12:13:52 Integrated Voltage Measurement... 12:14:01 Voltage Offset Correction: v_off_ini = 187.250 uV, v_off_fin = 179.412 uV 12:14:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.517 uVs 12:14:01 Integrated Voltage Measurement... 12:14:10 Voltage Offset Correction: v_off_ini = 185.291 uV, v_off_fin = 198.342 uV 12:14:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.660 uVs 12:14:10 Integrated Voltage Measurement... 12:14:19 Voltage Offset Correction: v_off_ini = 197.118 uV, v_off_fin = 192.259 uV 12:14:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.215 uVs 12:14:19 Integrated Voltage Measurement... 12:14:28 Voltage Offset Correction: v_off_ini = 193.645 uV, v_off_fin = 197.004 uV 12:14:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.076 uVs 12:14:30 I2X Average and RMS of Measurements VT = -100.057 +- 2.597 uVs I2X = 9.205 +- 0.239 uTm^2 12:14:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:14:38 Integrated Voltage Measurement... 12:14:47 Voltage Offset Correction: v_off_ini = 188.543 uV, v_off_fin = 183.094 uV 12:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.989 uVs 12:14:47 Integrated Voltage Measurement... 12:14:56 Voltage Offset Correction: v_off_ini = 191.247 uV, v_off_fin = 187.533 uV 12:14:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.287 uVs 12:14:56 Integrated Voltage Measurement... 12:15:05 Voltage Offset Correction: v_off_ini = 191.646 uV, v_off_fin = 182.015 uV 12:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.288 uVs 12:15:05 Integrated Voltage Measurement... 12:15:14 Voltage Offset Correction: v_off_ini = 198.611 uV, v_off_fin = 196.189 uV 12:15:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.187 uVs 12:15:14 Integrated Voltage Measurement... 12:15:23 Voltage Offset Correction: v_off_ini = 196.646 uV, v_off_fin = 193.153 uV 12:15:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.501 uVs 12:15:23 Integrated Voltage Measurement... 12:15:32 Voltage Offset Correction: v_off_ini = 195.439 uV, v_off_fin = 192.286 uV 12:15:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.471 uVs 12:15:34 I2Y Average and RMS of Measurements VT = -331.621 +- 4.874 uVs I2Y = -30.509 +- 0.448 uTm^2 12:15:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:15:43 Integrated Voltage Measurement... 12:15:52 Voltage Offset Correction: v_off_ini = 192.655 uV, v_off_fin = 187.819 uV 12:15:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.155 uVs 12:15:52 Integrated Voltage Measurement... 12:16:01 Voltage Offset Correction: v_off_ini = 197.056 uV, v_off_fin = 206.842 uV 12:16:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.629 uVs 12:16:01 Integrated Voltage Measurement... 12:16:10 Voltage Offset Correction: v_off_ini = 200.061 uV, v_off_fin = 186.128 uV 12:16:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.461 uVs 12:16:10 Integrated Voltage Measurement... 12:16:19 Voltage Offset Correction: v_off_ini = 181.506 uV, v_off_fin = 190.681 uV 12:16:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.938 uVs 12:16:19 Integrated Voltage Measurement... 12:16:28 Voltage Offset Correction: v_off_ini = 198.332 uV, v_off_fin = 175.444 uV 12:16:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.411 uVs 12:16:28 Integrated Voltage Measurement... 12:16:37 Voltage Offset Correction: v_off_ini = 195.253 uV, v_off_fin = 194.293 uV 12:16:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.598 uVs 12:16:42 I1X Average and RMS of Measurements VT = -81.032 +- 5.294 uVs I1X = 16.207 +- 1.059 uTm 12:16:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:16:48 Integrated Voltage Measurement... 12:16:57 Voltage Offset Correction: v_off_ini = 200.825 uV, v_off_fin = 177.239 uV 12:16:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.209 uVs 12:16:57 Integrated Voltage Measurement... 12:17:06 Voltage Offset Correction: v_off_ini = 193.417 uV, v_off_fin = 203.865 uV 12:17:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.186 uVs 12:17:06 Integrated Voltage Measurement... 12:17:15 Voltage Offset Correction: v_off_ini = 187.543 uV, v_off_fin = 181.020 uV 12:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.232 uVs 12:17:15 Integrated Voltage Measurement... 12:17:24 Voltage Offset Correction: v_off_ini = 190.120 uV, v_off_fin = 202.328 uV 12:17:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 280.155 uVs 12:17:24 Integrated Voltage Measurement... 12:17:33 Voltage Offset Correction: v_off_ini = 196.511 uV, v_off_fin = 182.261 uV 12:17:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.567 uVs 12:17:33 Integrated Voltage Measurement... 12:17:42 Voltage Offset Correction: v_off_ini = 188.594 uV, v_off_fin = 201.468 uV 12:17:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.305 uVs 12:17:47 I1Y Average and RMS of Measurements VT = -263.442 +- 3.783 uVs I1Y = -52.688 +- 0.757 uTm 12:17:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:17:54 Integrated Voltage Measurement... 12:18:03 Voltage Offset Correction: v_off_ini = 187.716 uV, v_off_fin = 186.161 uV 12:18:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.708 uVs 12:18:03 Integrated Voltage Measurement... 12:18:12 Voltage Offset Correction: v_off_ini = 185.056 uV, v_off_fin = 189.199 uV 12:18:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.322 uVs 12:18:12 Integrated Voltage Measurement... 12:18:21 Voltage Offset Correction: v_off_ini = 180.370 uV, v_off_fin = 173.936 uV 12:18:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.669 uVs 12:18:21 Integrated Voltage Measurement... 12:18:30 Voltage Offset Correction: v_off_ini = 172.288 uV, v_off_fin = 190.749 uV 12:18:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.109 uVs 12:18:30 Integrated Voltage Measurement... 12:18:39 Voltage Offset Correction: v_off_ini = 192.017 uV, v_off_fin = 176.947 uV 12:18:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.578 uVs 12:18:39 Integrated Voltage Measurement... 12:18:48 Voltage Offset Correction: v_off_ini = 192.928 uV, v_off_fin = 186.803 uV 12:18:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.211 uVs 12:18:51 I2X Average and RMS of Measurements VT = -96.933 +- 7.930 uVs I2X = 8.918 +- 0.730 uTm^2 12:18:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:18:59 Integrated Voltage Measurement... 12:19:08 Voltage Offset Correction: v_off_ini = 173.522 uV, v_off_fin = 175.317 uV 12:19:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.049 uVs 12:19:08 Integrated Voltage Measurement... 12:19:17 Voltage Offset Correction: v_off_ini = 182.965 uV, v_off_fin = 171.994 uV 12:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.942 uVs 12:19:17 Integrated Voltage Measurement... 12:19:26 Voltage Offset Correction: v_off_ini = 165.534 uV, v_off_fin = 163.917 uV 12:19:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.092 uVs 12:19:26 Integrated Voltage Measurement... 12:19:35 Voltage Offset Correction: v_off_ini = 165.326 uV, v_off_fin = 182.486 uV 12:19:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.841 uVs 12:19:35 Integrated Voltage Measurement... 12:19:44 Voltage Offset Correction: v_off_ini = 168.504 uV, v_off_fin = 175.750 uV 12:19:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.399 uVs 12:19:44 Integrated Voltage Measurement... 12:19:53 Voltage Offset Correction: v_off_ini = 179.293 uV, v_off_fin = 174.497 uV 12:19:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.599 uVs 12:19:55 I2Y Average and RMS of Measurements VT = -319.820 +- 3.438 uVs I2Y = -29.423 +- 0.316 uTm^2 12:20:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:04 Integrated Voltage Measurement... 12:20:13 Voltage Offset Correction: v_off_ini = 160.542 uV, v_off_fin = 166.079 uV 12:20:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -50.830 uVs 12:20:13 Integrated Voltage Measurement... 12:20:22 Voltage Offset Correction: v_off_ini = 174.135 uV, v_off_fin = 171.326 uV 12:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.332 uVs 12:20:22 Integrated Voltage Measurement... 12:20:31 Voltage Offset Correction: v_off_ini = 173.463 uV, v_off_fin = 155.485 uV 12:20:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.077 uVs 12:20:31 Integrated Voltage Measurement... 12:20:40 Voltage Offset Correction: v_off_ini = 166.555 uV, v_off_fin = 170.273 uV 12:20:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.472 uVs 12:20:40 Integrated Voltage Measurement... 12:20:49 Voltage Offset Correction: v_off_ini = 162.402 uV, v_off_fin = 152.147 uV 12:20:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.701 uVs 12:20:49 Integrated Voltage Measurement... 12:20:58 Voltage Offset Correction: v_off_ini = 154.967 uV, v_off_fin = 152.354 uV 12:20:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.042 uVs 12:21:02 I1X Average and RMS of Measurements VT = -67.242 +- 8.681 uVs I1X = 13.449 +- 1.736 uTm 12:21:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:09 Integrated Voltage Measurement... 12:21:18 Voltage Offset Correction: v_off_ini = 158.167 uV, v_off_fin = 157.712 uV 12:21:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -258.871 uVs 12:21:18 Integrated Voltage Measurement... 12:21:27 Voltage Offset Correction: v_off_ini = 166.660 uV, v_off_fin = 181.704 uV 12:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.353 uVs 12:21:27 Integrated Voltage Measurement... 12:21:36 Voltage Offset Correction: v_off_ini = 173.976 uV, v_off_fin = 160.923 uV 12:21:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.100 uVs 12:21:36 Integrated Voltage Measurement... 12:21:45 Voltage Offset Correction: v_off_ini = 169.023 uV, v_off_fin = 187.156 uV 12:21:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.349 uVs 12:21:45 Integrated Voltage Measurement... 12:21:54 Voltage Offset Correction: v_off_ini = 178.078 uV, v_off_fin = 165.109 uV 12:21:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.602 uVs 12:21:54 Integrated Voltage Measurement... 12:22:03 Voltage Offset Correction: v_off_ini = 159.637 uV, v_off_fin = 183.736 uV 12:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.234 uVs 12:22:07 I1Y Average and RMS of Measurements VT = -257.418 +- 3.394 uVs I1Y = -51.485 +- 0.681 uTm 12:22:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:15 Integrated Voltage Measurement... 12:22:24 Voltage Offset Correction: v_off_ini = 165.832 uV, v_off_fin = 165.086 uV 12:22:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.750 uVs 12:22:24 Integrated Voltage Measurement... 12:22:33 Voltage Offset Correction: v_off_ini = 176.159 uV, v_off_fin = 177.872 uV 12:22:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.198 uVs 12:22:33 Integrated Voltage Measurement... 12:22:42 Voltage Offset Correction: v_off_ini = 167.945 uV, v_off_fin = 165.421 uV 12:22:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.849 uVs 12:22:42 Integrated Voltage Measurement... 12:22:51 Voltage Offset Correction: v_off_ini = 171.250 uV, v_off_fin = 172.025 uV 12:22:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.024 uVs 12:22:51 Integrated Voltage Measurement... 12:23:00 Voltage Offset Correction: v_off_ini = 163.899 uV, v_off_fin = 146.831 uV 12:23:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.717 uVs 12:23:00 Integrated Voltage Measurement... 12:23:09 Voltage Offset Correction: v_off_ini = 154.640 uV, v_off_fin = 166.166 uV 12:23:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.084 uVs 12:23:12 I2X Average and RMS of Measurements VT = -91.770 +- 1.857 uVs I2X = 8.443 +- 0.171 uTm^2 12:23:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:23:19 Integrated Voltage Measurement... 12:23:28 Voltage Offset Correction: v_off_ini = 151.200 uV, v_off_fin = 158.683 uV 12:23:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.877 uVs 12:23:28 Integrated Voltage Measurement... 12:23:37 Voltage Offset Correction: v_off_ini = 135.829 uV, v_off_fin = 148.230 uV 12:23:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.122 uVs 12:23:37 Integrated Voltage Measurement... 12:23:46 Voltage Offset Correction: v_off_ini = 154.939 uV, v_off_fin = 150.201 uV 12:23:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.977 uVs 12:23:46 Integrated Voltage Measurement... 12:23:55 Voltage Offset Correction: v_off_ini = 155.763 uV, v_off_fin = 147.309 uV 12:23:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.826 uVs 12:23:55 Integrated Voltage Measurement... 12:24:04 Voltage Offset Correction: v_off_ini = 148.580 uV, v_off_fin = 162.498 uV 12:24:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.802 uVs 12:24:04 Integrated Voltage Measurement... 12:24:13 Voltage Offset Correction: v_off_ini = 160.168 uV, v_off_fin = 152.548 uV 12:24:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.169 uVs 12:24:16 I2Y Average and RMS of Measurements VT = -324.629 +- 4.050 uVs I2Y = -29.866 +- 0.373 uTm^2 12:24:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:24:25 Integrated Voltage Measurement... 12:24:34 Voltage Offset Correction: v_off_ini = 159.741 uV, v_off_fin = 153.882 uV 12:24:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.448 uVs 12:24:34 Integrated Voltage Measurement... 12:24:43 Voltage Offset Correction: v_off_ini = 154.924 uV, v_off_fin = 159.930 uV 12:24:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.823 uVs 12:24:43 Integrated Voltage Measurement... 12:24:52 Voltage Offset Correction: v_off_ini = 154.948 uV, v_off_fin = 153.376 uV 12:24:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.823 uVs 12:24:52 Integrated Voltage Measurement... 12:25:01 Voltage Offset Correction: v_off_ini = 154.348 uV, v_off_fin = 159.656 uV 12:25:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 80.997 uVs 12:25:01 Integrated Voltage Measurement... 12:25:10 Voltage Offset Correction: v_off_ini = 153.522 uV, v_off_fin = 164.745 uV 12:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.324 uVs 12:25:10 Integrated Voltage Measurement... 12:25:19 Voltage Offset Correction: v_off_ini = 168.455 uV, v_off_fin = 172.732 uV 12:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.801 uVs 12:25:23 I1X Average and RMS of Measurements VT = -73.036 +- 6.503 uVs I1X = 14.608 +- 1.300 uTm 12:25:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:25:30 Integrated Voltage Measurement... 12:25:39 Voltage Offset Correction: v_off_ini = 171.247 uV, v_off_fin = 148.585 uV 12:25:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.361 uVs 12:25:39 Integrated Voltage Measurement... 12:25:48 Voltage Offset Correction: v_off_ini = 162.601 uV, v_off_fin = 167.387 uV 12:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.070 uVs 12:25:48 Integrated Voltage Measurement... 12:25:57 Voltage Offset Correction: v_off_ini = 161.209 uV, v_off_fin = 152.014 uV 12:25:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.400 uVs 12:25:57 Integrated Voltage Measurement... 12:26:06 Voltage Offset Correction: v_off_ini = 169.422 uV, v_off_fin = 176.514 uV 12:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.287 uVs 12:26:06 Integrated Voltage Measurement... 12:26:15 Voltage Offset Correction: v_off_ini = 164.931 uV, v_off_fin = 153.944 uV 12:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.909 uVs 12:26:15 Integrated Voltage Measurement... 12:26:24 Voltage Offset Correction: v_off_ini = 166.258 uV, v_off_fin = 168.851 uV 12:26:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.082 uVs 12:26:28 I1Y Average and RMS of Measurements VT = -262.018 +- 4.396 uVs I1Y = -52.404 +- 0.879 uTm 12:26:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:26:36 Integrated Voltage Measurement... 12:26:45 Voltage Offset Correction: v_off_ini = 146.886 uV, v_off_fin = 142.593 uV 12:26:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.755 uVs 12:26:45 Integrated Voltage Measurement... 12:26:54 Voltage Offset Correction: v_off_ini = 147.724 uV, v_off_fin = 164.212 uV 12:26:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.968 uVs 12:26:54 Integrated Voltage Measurement... 12:27:03 Voltage Offset Correction: v_off_ini = 151.731 uV, v_off_fin = 142.974 uV 12:27:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.867 uVs 12:27:03 Integrated Voltage Measurement... 12:27:12 Voltage Offset Correction: v_off_ini = 156.250 uV, v_off_fin = 170.331 uV 12:27:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.109 uVs 12:27:12 Integrated Voltage Measurement... 12:27:21 Voltage Offset Correction: v_off_ini = 171.001 uV, v_off_fin = 173.697 uV 12:27:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.534 uVs 12:27:21 Integrated Voltage Measurement... 12:27:30 Voltage Offset Correction: v_off_ini = 179.820 uV, v_off_fin = 194.629 uV 12:27:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.563 uVs 12:27:32 I2X Average and RMS of Measurements VT = -87.799 +- 3.446 uVs I2X = 8.078 +- 0.317 uTm^2 12:27:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:27:40 Integrated Voltage Measurement... 12:27:49 Voltage Offset Correction: v_off_ini = 173.075 uV, v_off_fin = 166.507 uV 12:27:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.172 uVs 12:27:49 Integrated Voltage Measurement... 12:27:58 Voltage Offset Correction: v_off_ini = 168.218 uV, v_off_fin = 170.566 uV 12:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.406 uVs 12:27:58 Integrated Voltage Measurement... 12:28:07 Voltage Offset Correction: v_off_ini = 163.610 uV, v_off_fin = 167.358 uV 12:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.345 uVs 12:28:07 Integrated Voltage Measurement... 12:28:16 Voltage Offset Correction: v_off_ini = 173.860 uV, v_off_fin = 172.586 uV 12:28:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.372 uVs 12:28:16 Integrated Voltage Measurement... 12:28:25 Voltage Offset Correction: v_off_ini = 170.396 uV, v_off_fin = 173.581 uV 12:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.312 uVs 12:28:25 Integrated Voltage Measurement... 12:28:34 Voltage Offset Correction: v_off_ini = 171.147 uV, v_off_fin = 165.221 uV 12:28:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.704 uVs 12:28:37 I2Y Average and RMS of Measurements VT = -321.719 +- 1.894 uVs I2Y = -29.598 +- 0.174 uTm^2 12:28:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:28:45 Integrated Voltage Measurement... 12:28:54 Voltage Offset Correction: v_off_ini = 161.084 uV, v_off_fin = 154.684 uV 12:28:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.115 uVs 12:28:54 Integrated Voltage Measurement... 12:29:03 Voltage Offset Correction: v_off_ini = 162.382 uV, v_off_fin = 163.460 uV 12:29:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.675 uVs 12:29:04 Integrated Voltage Measurement... 12:29:12 Voltage Offset Correction: v_off_ini = 158.046 uV, v_off_fin = 152.999 uV 12:29:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -66.114 uVs 12:29:13 Integrated Voltage Measurement... 12:29:21 Voltage Offset Correction: v_off_ini = 149.786 uV, v_off_fin = 155.419 uV 12:29:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 84.392 uVs 12:29:22 Integrated Voltage Measurement... 12:29:30 Voltage Offset Correction: v_off_ini = 153.335 uV, v_off_fin = 132.387 uV 12:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.404 uVs 12:29:31 Integrated Voltage Measurement... 12:29:39 Voltage Offset Correction: v_off_ini = 140.587 uV, v_off_fin = 141.350 uV 12:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.310 uVs 12:29:44 I1X Average and RMS of Measurements VT = -66.502 +- 7.312 uVs I1X = 13.302 +- 1.463 uTm 12:29:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:29:51 Integrated Voltage Measurement... 12:29:59 Voltage Offset Correction: v_off_ini = 130.353 uV, v_off_fin = 129.233 uV 12:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.244 uVs 12:30:00 Integrated Voltage Measurement... 12:30:08 Voltage Offset Correction: v_off_ini = 131.398 uV, v_off_fin = 147.526 uV 12:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.601 uVs 12:30:09 Integrated Voltage Measurement... 12:30:17 Voltage Offset Correction: v_off_ini = 152.423 uV, v_off_fin = 135.770 uV 12:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.055 uVs 12:30:18 Integrated Voltage Measurement... 12:30:26 Voltage Offset Correction: v_off_ini = 141.003 uV, v_off_fin = 155.467 uV 12:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.396 uVs 12:30:27 Integrated Voltage Measurement... 12:30:36 Voltage Offset Correction: v_off_ini = 151.196 uV, v_off_fin = 126.858 uV 12:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.988 uVs 12:30:36 Integrated Voltage Measurement... 12:30:44 Voltage Offset Correction: v_off_ini = 148.067 uV, v_off_fin = 153.525 uV 12:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.112 uVs 12:30:49 I1Y Average and RMS of Measurements VT = -259.566 +- 6.886 uVs I1Y = -51.913 +- 1.377 uTm 12:30:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:30:56 Integrated Voltage Measurement... 12:31:05 Voltage Offset Correction: v_off_ini = 162.464 uV, v_off_fin = 152.467 uV 12:31:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.893 uVs 12:31:05 Integrated Voltage Measurement... 12:31:14 Voltage Offset Correction: v_off_ini = 157.577 uV, v_off_fin = 164.446 uV 12:31:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.136 uVs 12:31:15 Integrated Voltage Measurement... 12:31:23 Voltage Offset Correction: v_off_ini = 154.589 uV, v_off_fin = 140.878 uV 12:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.463 uVs 12:31:24 Integrated Voltage Measurement... 12:31:33 Voltage Offset Correction: v_off_ini = 122.300 uV, v_off_fin = 151.023 uV 12:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.745 uVs 12:31:33 Integrated Voltage Measurement... 12:31:42 Voltage Offset Correction: v_off_ini = 147.610 uV, v_off_fin = 137.927 uV 12:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.614 uVs 12:31:42 Integrated Voltage Measurement... 12:31:51 Voltage Offset Correction: v_off_ini = 146.753 uV, v_off_fin = 147.660 uV 12:31:51 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 97.162 uVs 12:31:53 I2X Average and RMS of Measurements VT = -98.669 +- 4.362 uVs I2X = 9.078 +- 0.401 uTm^2 12:31:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:32:01 Integrated Voltage Measurement... 12:32:10 Voltage Offset Correction: v_off_ini = 169.359 uV, v_off_fin = 163.896 uV 12:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.385 uVs 12:32:10 Integrated Voltage Measurement... 12:32:19 Voltage Offset Correction: v_off_ini = 172.345 uV, v_off_fin = 166.591 uV 12:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.085 uVs 12:32:19 Integrated Voltage Measurement... 12:32:28 Voltage Offset Correction: v_off_ini = 161.935 uV, v_off_fin = 158.733 uV 12:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.386 uVs 12:32:28 Integrated Voltage Measurement... 12:32:37 Voltage Offset Correction: v_off_ini = 168.327 uV, v_off_fin = 164.655 uV 12:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.660 uVs 12:32:37 Integrated Voltage Measurement... 12:32:46 Voltage Offset Correction: v_off_ini = 156.416 uV, v_off_fin = 146.237 uV 12:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.234 uVs 12:32:46 Integrated Voltage Measurement... 12:32:55 Voltage Offset Correction: v_off_ini = 154.460 uV, v_off_fin = 157.129 uV 12:32:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.223 uVs 12:32:57 I2Y Average and RMS of Measurements VT = -304.662 +- 8.857 uVs I2Y = -28.029 +- 0.815 uTm^2 12:33:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:33:09 Integrated Voltage Measurement... 12:33:18 Voltage Offset Correction: v_off_ini = 186.423 uV, v_off_fin = 175.113 uV 12:33:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -64.992 uVs 12:33:18 Integrated Voltage Measurement... 12:33:27 Voltage Offset Correction: v_off_ini = 172.556 uV, v_off_fin = 164.227 uV 12:33:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 68.601 uVs 12:33:27 Integrated Voltage Measurement... 12:33:36 Voltage Offset Correction: v_off_ini = 169.743 uV, v_off_fin = 163.653 uV 12:33:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.703 uVs 12:33:36 Integrated Voltage Measurement... 12:33:45 Voltage Offset Correction: v_off_ini = 184.231 uV, v_off_fin = 175.813 uV 12:33:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.847 uVs 12:33:45 Integrated Voltage Measurement... 12:33:54 Voltage Offset Correction: v_off_ini = 174.496 uV, v_off_fin = 176.346 uV 12:33:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.919 uVs 12:33:54 Integrated Voltage Measurement... 12:34:03 Voltage Offset Correction: v_off_ini = 179.166 uV, v_off_fin = 175.204 uV 12:34:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.629 uVs 12:34:08 I1X Average and RMS of Measurements VT = -57.449 +- 7.562 uVs I1X = 11.491 +- 1.513 uTm 12:34:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:34:14 Integrated Voltage Measurement... 12:34:23 Voltage Offset Correction: v_off_ini = 164.073 uV, v_off_fin = 162.916 uV 12:34:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.899 uVs 12:34:23 Integrated Voltage Measurement... 12:34:32 Voltage Offset Correction: v_off_ini = 176.583 uV, v_off_fin = 185.858 uV 12:34:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.483 uVs 12:34:32 Integrated Voltage Measurement... 12:34:41 Voltage Offset Correction: v_off_ini = 173.088 uV, v_off_fin = 157.368 uV 12:34:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.895 uVs 12:34:41 Integrated Voltage Measurement... 12:34:50 Voltage Offset Correction: v_off_ini = 167.397 uV, v_off_fin = 178.842 uV 12:34:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.127 uVs 12:34:50 Integrated Voltage Measurement... 12:34:59 Voltage Offset Correction: v_off_ini = 156.105 uV, v_off_fin = 157.268 uV 12:34:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.023 uVs 12:34:59 Integrated Voltage Measurement... 12:35:08 Voltage Offset Correction: v_off_ini = 163.269 uV, v_off_fin = 166.794 uV 12:35:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.015 uVs 12:35:12 I1Y Average and RMS of Measurements VT = -256.074 +- 7.377 uVs I1Y = -51.215 +- 1.475 uTm 12:35:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:35:18 Integrated Voltage Measurement... 12:35:27 Voltage Offset Correction: v_off_ini = 147.367 uV, v_off_fin = 158.286 uV 12:35:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -75.562 uVs 12:35:27 Integrated Voltage Measurement... 12:35:36 Voltage Offset Correction: v_off_ini = 169.702 uV, v_off_fin = 179.393 uV 12:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.780 uVs 12:35:36 Integrated Voltage Measurement... 12:35:45 Voltage Offset Correction: v_off_ini = 168.216 uV, v_off_fin = 167.448 uV 12:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.705 uVs 12:35:45 Integrated Voltage Measurement... 12:35:54 Voltage Offset Correction: v_off_ini = 160.585 uV, v_off_fin = 163.388 uV 12:35:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.084 uVs 12:35:54 Integrated Voltage Measurement... 12:36:03 Voltage Offset Correction: v_off_ini = 157.566 uV, v_off_fin = 148.063 uV 12:36:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.900 uVs 12:36:03 Integrated Voltage Measurement... 12:36:12 Voltage Offset Correction: v_off_ini = 171.460 uV, v_off_fin = 169.633 uV 12:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.902 uVs 12:36:14 I2X Average and RMS of Measurements VT = -76.489 +- 7.961 uVs I2X = 7.037 +- 0.732 uTm^2 12:36:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:36:19 Integrated Voltage Measurement... 12:36:28 Voltage Offset Correction: v_off_ini = 162.122 uV, v_off_fin = 171.206 uV 12:36:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.556 uVs 12:36:28 Integrated Voltage Measurement... 12:36:37 Voltage Offset Correction: v_off_ini = 159.923 uV, v_off_fin = 167.252 uV 12:36:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.360 uVs 12:36:37 Integrated Voltage Measurement... 12:36:46 Voltage Offset Correction: v_off_ini = 162.585 uV, v_off_fin = 158.091 uV 12:36:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.547 uVs 12:36:46 Integrated Voltage Measurement... 12:36:55 Voltage Offset Correction: v_off_ini = 167.558 uV, v_off_fin = 169.996 uV 12:36:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.091 uVs 12:36:55 Integrated Voltage Measurement... 12:37:04 Voltage Offset Correction: v_off_ini = 162.150 uV, v_off_fin = 156.711 uV 12:37:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.265 uVs 12:37:05 Integrated Voltage Measurement... 12:37:13 Voltage Offset Correction: v_off_ini = 166.123 uV, v_off_fin = 155.381 uV 12:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.678 uVs 12:37:16 I2Y Average and RMS of Measurements VT = -317.916 +- 3.487 uVs I2Y = -29.248 +- 0.321 uTm^2 12:37:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:37:24 Integrated Voltage Measurement... 12:37:33 Voltage Offset Correction: v_off_ini = 177.457 uV, v_off_fin = 172.900 uV 12:37:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -91.704 uVs 12:37:33 Integrated Voltage Measurement... 12:37:42 Voltage Offset Correction: v_off_ini = 170.035 uV, v_off_fin = 174.523 uV 12:37:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 66.163 uVs 12:37:42 Integrated Voltage Measurement... 12:37:51 Voltage Offset Correction: v_off_ini = 175.836 uV, v_off_fin = 177.223 uV 12:37:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.281 uVs 12:37:51 Integrated Voltage Measurement... 12:38:00 Voltage Offset Correction: v_off_ini = 173.216 uV, v_off_fin = 170.999 uV 12:38:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.863 uVs 12:38:00 Integrated Voltage Measurement... 12:38:09 Voltage Offset Correction: v_off_ini = 173.196 uV, v_off_fin = 169.190 uV 12:38:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.951 uVs 12:38:09 Integrated Voltage Measurement... 12:38:18 Voltage Offset Correction: v_off_ini = 172.445 uV, v_off_fin = 173.199 uV 12:38:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.732 uVs 12:38:22 I1X Average and RMS of Measurements VT = -77.449 +- 2.035 uVs I1X = 15.491 +- 0.408 uTm 12:38:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:38:29 Integrated Voltage Measurement... 12:38:38 Voltage Offset Correction: v_off_ini = 180.437 uV, v_off_fin = 163.815 uV 12:38:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -280.679 uVs 12:38:38 Integrated Voltage Measurement... 12:38:47 Voltage Offset Correction: v_off_ini = 164.996 uV, v_off_fin = 175.126 uV 12:38:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.228 uVs 12:38:47 Integrated Voltage Measurement... 12:38:56 Voltage Offset Correction: v_off_ini = 171.357 uV, v_off_fin = 154.513 uV 12:38:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.775 uVs 12:38:56 Integrated Voltage Measurement... 12:39:05 Voltage Offset Correction: v_off_ini = 180.429 uV, v_off_fin = 189.706 uV 12:39:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.036 uVs 12:39:05 Integrated Voltage Measurement... 12:39:14 Voltage Offset Correction: v_off_ini = 184.849 uV, v_off_fin = 168.772 uV 12:39:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.923 uVs 12:39:14 Integrated Voltage Measurement... 12:39:23 Voltage Offset Correction: v_off_ini = 188.136 uV, v_off_fin = 191.856 uV 12:39:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.590 uVs 12:39:27 I1Y Average and RMS of Measurements VT = -259.872 +- 9.404 uVs I1Y = -51.976 +- 1.883 uTm 12:39:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:39:33 Integrated Voltage Measurement... 12:39:42 Voltage Offset Correction: v_off_ini = 192.767 uV, v_off_fin = 180.144 uV 12:39:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.692 uVs 12:39:42 Integrated Voltage Measurement... 12:39:51 Voltage Offset Correction: v_off_ini = 187.373 uV, v_off_fin = 200.979 uV 12:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.437 uVs 12:39:51 Integrated Voltage Measurement... 12:40:00 Voltage Offset Correction: v_off_ini = 197.547 uV, v_off_fin = 165.353 uV 12:40:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.601 uVs 12:40:00 Integrated Voltage Measurement... 12:40:09 Voltage Offset Correction: v_off_ini = 186.292 uV, v_off_fin = 201.441 uV 12:40:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.772 uVs 12:40:09 Integrated Voltage Measurement... 12:40:18 Voltage Offset Correction: v_off_ini = 190.745 uV, v_off_fin = 181.403 uV 12:40:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.655 uVs 12:40:18 Integrated Voltage Measurement... 12:40:27 Voltage Offset Correction: v_off_ini = 195.164 uV, v_off_fin = 190.437 uV 12:40:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.625 uVs 12:40:29 I2X Average and RMS of Measurements VT = -86.463 +- 5.525 uVs I2X = 7.955 +- 0.508 uTm^2 12:40:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:40:34 Integrated Voltage Measurement... 12:40:43 Voltage Offset Correction: v_off_ini = 194.995 uV, v_off_fin = 186.735 uV 12:40:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.164 uVs 12:40:43 Integrated Voltage Measurement... 12:40:52 Voltage Offset Correction: v_off_ini = 188.311 uV, v_off_fin = 186.208 uV 12:40:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.812 uVs 12:40:52 Integrated Voltage Measurement... 12:41:01 Voltage Offset Correction: v_off_ini = 192.167 uV, v_off_fin = 200.197 uV 12:41:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.187 uVs 12:41:01 Integrated Voltage Measurement... 12:41:10 Voltage Offset Correction: v_off_ini = 196.344 uV, v_off_fin = 195.509 uV 12:41:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.579 uVs 12:41:10 Integrated Voltage Measurement... 12:41:19 Voltage Offset Correction: v_off_ini = 194.668 uV, v_off_fin = 196.083 uV 12:41:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.406 uVs 12:41:19 Integrated Voltage Measurement... 12:41:28 Voltage Offset Correction: v_off_ini = 195.561 uV, v_off_fin = 200.744 uV 12:41:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.475 uVs 12:41:31 I2Y Average and RMS of Measurements VT = -318.604 +- 4.486 uVs I2Y = -29.312 +- 0.413 uTm^2 12:41:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:39 Integrated Voltage Measurement... 12:41:48 Voltage Offset Correction: v_off_ini = 180.250 uV, v_off_fin = 181.766 uV 12:41:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.049 uVs 12:41:48 Integrated Voltage Measurement... 12:41:57 Voltage Offset Correction: v_off_ini = 176.564 uV, v_off_fin = 183.748 uV 12:41:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.369 uVs 12:41:57 Integrated Voltage Measurement... 12:42:06 Voltage Offset Correction: v_off_ini = 182.401 uV, v_off_fin = 186.567 uV 12:42:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.264 uVs 12:42:06 Integrated Voltage Measurement... 12:42:15 Voltage Offset Correction: v_off_ini = 188.832 uV, v_off_fin = 179.858 uV 12:42:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.631 uVs 12:42:15 Integrated Voltage Measurement... 12:42:24 Voltage Offset Correction: v_off_ini = 164.166 uV, v_off_fin = 161.498 uV 12:42:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.852 uVs 12:42:24 Integrated Voltage Measurement... 12:42:33 Voltage Offset Correction: v_off_ini = 162.666 uV, v_off_fin = 168.840 uV 12:42:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.269 uVs 12:42:37 I1X Average and RMS of Measurements VT = -71.072 +- 10.008 uVs I1X = 14.215 +- 2.001 uTm 12:42:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:44 Integrated Voltage Measurement... 12:42:53 Voltage Offset Correction: v_off_ini = 170.446 uV, v_off_fin = 161.279 uV 12:42:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.523 uVs 12:42:53 Integrated Voltage Measurement... 12:43:02 Voltage Offset Correction: v_off_ini = 169.128 uV, v_off_fin = 165.393 uV 12:43:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.412 uVs 12:43:02 Integrated Voltage Measurement... 12:43:11 Voltage Offset Correction: v_off_ini = 157.733 uV, v_off_fin = 147.612 uV 12:43:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.043 uVs 12:43:11 Integrated Voltage Measurement... 12:43:20 Voltage Offset Correction: v_off_ini = 152.526 uV, v_off_fin = 170.727 uV 12:43:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.043 uVs 12:43:20 Integrated Voltage Measurement... 12:43:29 Voltage Offset Correction: v_off_ini = 166.223 uV, v_off_fin = 151.939 uV 12:43:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.214 uVs 12:43:29 Integrated Voltage Measurement... 12:43:38 Voltage Offset Correction: v_off_ini = 168.865 uV, v_off_fin = 181.891 uV 12:43:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.172 uVs 12:43:42 I1Y Average and RMS of Measurements VT = -261.234 +- 5.698 uVs I1Y = -52.247 +- 1.140 uTm 12:43:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:47 Integrated Voltage Measurement... 12:43:56 Voltage Offset Correction: v_off_ini = 164.889 uV, v_off_fin = 143.230 uV 12:43:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.104 uVs 12:43:56 Integrated Voltage Measurement... 12:44:05 Voltage Offset Correction: v_off_ini = 166.199 uV, v_off_fin = 173.164 uV 12:44:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.177 uVs 12:44:05 Integrated Voltage Measurement... 12:44:14 Voltage Offset Correction: v_off_ini = 153.793 uV, v_off_fin = 150.121 uV 12:44:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.860 uVs 12:44:14 Integrated Voltage Measurement... 12:44:23 Voltage Offset Correction: v_off_ini = 121.054 uV, v_off_fin = 147.003 uV 12:44:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.345 uVs 12:44:23 Integrated Voltage Measurement... 12:44:32 Voltage Offset Correction: v_off_ini = 142.548 uV, v_off_fin = 135.052 uV 12:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.308 uVs 12:44:32 Integrated Voltage Measurement... 12:44:41 Voltage Offset Correction: v_off_ini = 139.721 uV, v_off_fin = 157.438 uV 12:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.366 uVs 12:44:43 I2X Average and RMS of Measurements VT = -91.360 +- 4.207 uVs I2X = 8.405 +- 0.387 uTm^2 12:44:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:49 Integrated Voltage Measurement... 12:44:58 Voltage Offset Correction: v_off_ini = 140.627 uV, v_off_fin = 144.928 uV 12:44:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.608 uVs 12:44:58 Integrated Voltage Measurement... 12:45:07 Voltage Offset Correction: v_off_ini = 148.991 uV, v_off_fin = 144.643 uV 12:45:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.578 uVs 12:45:07 Integrated Voltage Measurement... 12:45:16 Voltage Offset Correction: v_off_ini = 131.577 uV, v_off_fin = 126.571 uV 12:45:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.592 uVs 12:45:16 Integrated Voltage Measurement... 12:45:25 Voltage Offset Correction: v_off_ini = 132.426 uV, v_off_fin = 146.498 uV 12:45:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.013 uVs 12:45:25 Integrated Voltage Measurement... 12:45:34 Voltage Offset Correction: v_off_ini = 136.251 uV, v_off_fin = 137.616 uV 12:45:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.646 uVs 12:45:34 Integrated Voltage Measurement... 12:45:43 Voltage Offset Correction: v_off_ini = 144.584 uV, v_off_fin = 126.398 uV 12:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.472 uVs 12:45:45 I2Y Average and RMS of Measurements VT = -316.152 +- 6.176 uVs I2Y = -29.086 +- 0.568 uTm^2 12:45:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:45:53 Integrated Voltage Measurement... 12:46:02 Voltage Offset Correction: v_off_ini = 133.394 uV, v_off_fin = 131.764 uV 12:46:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.720 uVs 12:46:02 Integrated Voltage Measurement... 12:46:11 Voltage Offset Correction: v_off_ini = 130.365 uV, v_off_fin = 138.834 uV 12:46:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 78.209 uVs 12:46:11 Integrated Voltage Measurement... 12:46:20 Voltage Offset Correction: v_off_ini = 129.823 uV, v_off_fin = 127.596 uV 12:46:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.091 uVs 12:46:20 Integrated Voltage Measurement... 12:46:29 Voltage Offset Correction: v_off_ini = 138.923 uV, v_off_fin = 153.339 uV 12:46:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.166 uVs 12:46:29 Integrated Voltage Measurement... 12:46:38 Voltage Offset Correction: v_off_ini = 138.326 uV, v_off_fin = 135.833 uV 12:46:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -71.895 uVs 12:46:38 Integrated Voltage Measurement... 12:46:47 Voltage Offset Correction: v_off_ini = 138.868 uV, v_off_fin = 139.721 uV 12:46:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.357 uVs 12:46:52 I1X Average and RMS of Measurements VT = -64.740 +- 9.335 uVs I1X = 12.949 +- 1.867 uTm 12:46:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:46:58 Integrated Voltage Measurement... 12:47:07 Voltage Offset Correction: v_off_ini = 121.527 uV, v_off_fin = 119.316 uV 12:47:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.568 uVs 12:47:07 Integrated Voltage Measurement... 12:47:16 Voltage Offset Correction: v_off_ini = 131.097 uV, v_off_fin = 133.066 uV 12:47:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.873 uVs 12:47:16 Integrated Voltage Measurement... 12:47:25 Voltage Offset Correction: v_off_ini = 124.704 uV, v_off_fin = 114.238 uV 12:47:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.534 uVs 12:47:25 Integrated Voltage Measurement... 12:47:34 Voltage Offset Correction: v_off_ini = 125.228 uV, v_off_fin = 136.096 uV 12:47:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.192 uVs 12:47:34 Integrated Voltage Measurement... 12:47:43 Voltage Offset Correction: v_off_ini = 135.828 uV, v_off_fin = 124.203 uV 12:47:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.308 uVs 12:47:43 Integrated Voltage Measurement... 12:47:52 Voltage Offset Correction: v_off_ini = 143.063 uV, v_off_fin = 151.998 uV 12:47:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.539 uVs 12:47:56 I1Y Average and RMS of Measurements VT = -257.336 +- 2.207 uVs I1Y = -51.467 +- 0.441 uTm 12:47:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:48:02 Integrated Voltage Measurement... 12:48:11 Voltage Offset Correction: v_off_ini = 133.813 uV, v_off_fin = 132.675 uV 12:48:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.628 uVs 12:48:11 Integrated Voltage Measurement... 12:48:20 Voltage Offset Correction: v_off_ini = 140.651 uV, v_off_fin = 150.525 uV 12:48:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.809 uVs 12:48:20 Integrated Voltage Measurement... 12:48:29 Voltage Offset Correction: v_off_ini = 142.971 uV, v_off_fin = 128.520 uV 12:48:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.439 uVs 12:48:29 Integrated Voltage Measurement... 12:48:38 Voltage Offset Correction: v_off_ini = 149.984 uV, v_off_fin = 145.412 uV 12:48:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.943 uVs 12:48:38 Integrated Voltage Measurement... 12:48:47 Voltage Offset Correction: v_off_ini = 125.870 uV, v_off_fin = 114.950 uV 12:48:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.901 uVs 12:48:47 Integrated Voltage Measurement... 12:48:56 Voltage Offset Correction: v_off_ini = 140.122 uV, v_off_fin = 140.341 uV 12:48:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.595 uVs 12:48:58 I2X Average and RMS of Measurements VT = -81.886 +- 5.962 uVs I2X = 7.533 +- 0.548 uTm^2 12:49:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:49:03 Integrated Voltage Measurement... 12:49:12 Voltage Offset Correction: v_off_ini = 159.774 uV, v_off_fin = 146.744 uV 12:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.974 uVs 12:49:12 Integrated Voltage Measurement... 12:49:21 Voltage Offset Correction: v_off_ini = 145.918 uV, v_off_fin = 142.584 uV 12:49:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.665 uVs 12:49:21 Integrated Voltage Measurement... 12:49:30 Voltage Offset Correction: v_off_ini = 136.198 uV, v_off_fin = 142.370 uV 12:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.764 uVs 12:49:30 Integrated Voltage Measurement... 12:49:39 Voltage Offset Correction: v_off_ini = 140.182 uV, v_off_fin = 142.317 uV 12:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.168 uVs 12:49:39 Integrated Voltage Measurement... 12:49:48 Voltage Offset Correction: v_off_ini = 145.140 uV, v_off_fin = 142.972 uV 12:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.571 uVs 12:49:48 Integrated Voltage Measurement... 12:49:57 Voltage Offset Correction: v_off_ini = 137.016 uV, v_off_fin = 147.983 uV 12:49:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.249 uVs 12:50:00 I2Y Average and RMS of Measurements VT = -320.732 +- 8.149 uVs I2Y = -29.507 +- 0.750 uTm^2 12:50:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:50:08 Integrated Voltage Measurement... 12:50:17 Voltage Offset Correction: v_off_ini = 134.534 uV, v_off_fin = 141.267 uV 12:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.740 uVs 12:50:17 Integrated Voltage Measurement... 12:50:26 Voltage Offset Correction: v_off_ini = 141.069 uV, v_off_fin = 156.560 uV 12:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.550 uVs 12:50:26 Integrated Voltage Measurement... 12:50:35 Voltage Offset Correction: v_off_ini = 146.470 uV, v_off_fin = 141.214 uV 12:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.321 uVs 12:50:35 Integrated Voltage Measurement... 12:50:44 Voltage Offset Correction: v_off_ini = 149.255 uV, v_off_fin = 136.338 uV 12:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.309 uVs 12:50:44 Integrated Voltage Measurement... 12:50:53 Voltage Offset Correction: v_off_ini = 134.534 uV, v_off_fin = 138.088 uV 12:50:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.233 uVs 12:50:53 Integrated Voltage Measurement... 12:51:02 Voltage Offset Correction: v_off_ini = 130.123 uV, v_off_fin = 140.933 uV 12:51:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.618 uVs 12:51:06 I1X Average and RMS of Measurements VT = -65.629 +- 6.417 uVs I1X = 13.126 +- 1.283 uTm 12:51:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:51:13 Integrated Voltage Measurement... 12:51:22 Voltage Offset Correction: v_off_ini = 144.705 uV, v_off_fin = 135.145 uV 12:51:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.276 uVs 12:51:22 Integrated Voltage Measurement... 12:51:31 Voltage Offset Correction: v_off_ini = 142.292 uV, v_off_fin = 164.982 uV 12:51:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 270.235 uVs 12:51:31 Integrated Voltage Measurement... 12:51:40 Voltage Offset Correction: v_off_ini = 168.833 uV, v_off_fin = 145.591 uV 12:51:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -265.491 uVs 12:51:40 Integrated Voltage Measurement... 12:51:49 Voltage Offset Correction: v_off_ini = 147.905 uV, v_off_fin = 158.360 uV 12:51:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.799 uVs 12:51:49 Integrated Voltage Measurement... 12:51:58 Voltage Offset Correction: v_off_ini = 138.996 uV, v_off_fin = 141.219 uV 12:51:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.146 uVs 12:51:58 Integrated Voltage Measurement... 12:52:07 Voltage Offset Correction: v_off_ini = 140.523 uV, v_off_fin = 155.556 uV 12:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.183 uVs 12:52:11 I1Y Average and RMS of Measurements VT = -259.522 +- 7.878 uVs I1Y = -51.901 +- 1.575 uTm 12:52:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:52:16 Integrated Voltage Measurement... 12:52:25 Voltage Offset Correction: v_off_ini = 160.545 uV, v_off_fin = 159.227 uV 12:52:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.055 uVs 12:52:25 Integrated Voltage Measurement... 12:52:34 Voltage Offset Correction: v_off_ini = 157.241 uV, v_off_fin = 178.001 uV 12:52:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.506 uVs 12:52:34 Integrated Voltage Measurement... 12:52:43 Voltage Offset Correction: v_off_ini = 167.198 uV, v_off_fin = 149.335 uV 12:52:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.494 uVs 12:52:43 Integrated Voltage Measurement... 12:52:52 Voltage Offset Correction: v_off_ini = 169.061 uV, v_off_fin = 180.490 uV 12:52:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.028 uVs 12:52:52 Integrated Voltage Measurement... 12:53:01 Voltage Offset Correction: v_off_ini = 165.947 uV, v_off_fin = 147.560 uV 12:53:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.247 uVs 12:53:01 Integrated Voltage Measurement... 12:53:10 Voltage Offset Correction: v_off_ini = 158.814 uV, v_off_fin = 160.037 uV 12:53:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.190 uVs 12:53:13 I2X Average and RMS of Measurements VT = -88.920 +- 7.510 uVs I2X = 8.181 +- 0.691 uTm^2 12:53:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:53:18 Integrated Voltage Measurement... 12:53:27 Voltage Offset Correction: v_off_ini = 150.008 uV, v_off_fin = 157.580 uV 12:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.022 uVs 12:53:27 Integrated Voltage Measurement... 12:53:36 Voltage Offset Correction: v_off_ini = 152.859 uV, v_off_fin = 152.160 uV 12:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.363 uVs 12:53:36 Integrated Voltage Measurement... 12:53:45 Voltage Offset Correction: v_off_ini = 139.559 uV, v_off_fin = 153.550 uV 12:53:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.380 uVs 12:53:45 Integrated Voltage Measurement... 12:53:54 Voltage Offset Correction: v_off_ini = 153.280 uV, v_off_fin = 151.198 uV 12:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.080 uVs 12:53:54 Integrated Voltage Measurement... 12:54:03 Voltage Offset Correction: v_off_ini = 165.906 uV, v_off_fin = 159.234 uV 12:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.197 uVs 12:54:03 Integrated Voltage Measurement... 12:54:12 Voltage Offset Correction: v_off_ini = 165.729 uV, v_off_fin = 158.603 uV 12:54:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 311.829 uVs 12:54:14 I2Y Average and RMS of Measurements VT = -313.478 +- 1.005 uVs I2Y = -28.840 +- 0.093 uTm^2 12:54:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:54:36 Integrated Voltage Measurement... 12:54:45 Voltage Offset Correction: v_off_ini = 164.951 uV, v_off_fin = 159.094 uV 12:54:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.855 uVs 12:54:45 Integrated Voltage Measurement... 12:54:54 Voltage Offset Correction: v_off_ini = 166.723 uV, v_off_fin = 165.915 uV 12:54:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.910 uVs 12:54:54 Integrated Voltage Measurement... 12:55:03 Voltage Offset Correction: v_off_ini = 148.304 uV, v_off_fin = 146.455 uV 12:55:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.006 uVs 12:55:03 Integrated Voltage Measurement... 12:55:12 Voltage Offset Correction: v_off_ini = 159.988 uV, v_off_fin = 157.003 uV 12:55:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.026 uVs 12:55:12 Integrated Voltage Measurement... 12:55:21 Voltage Offset Correction: v_off_ini = 153.218 uV, v_off_fin = 169.562 uV 12:55:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.723 uVs 12:55:21 Integrated Voltage Measurement... 12:55:30 Voltage Offset Correction: v_off_ini = 177.983 uV, v_off_fin = 163.590 uV 12:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.973 uVs 12:55:34 I1X Average and RMS of Measurements VT = -74.582 +- 2.496 uVs I1X = 14.916 +- 0.499 uTm 12:55:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:55:41 Integrated Voltage Measurement... 12:55:50 Voltage Offset Correction: v_off_ini = 169.174 uV, v_off_fin = 158.827 uV 12:55:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.436 uVs 12:55:50 Integrated Voltage Measurement... 12:55:59 Voltage Offset Correction: v_off_ini = 164.410 uV, v_off_fin = 173.970 uV 12:55:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.701 uVs 12:55:59 Integrated Voltage Measurement... 12:56:08 Voltage Offset Correction: v_off_ini = 159.624 uV, v_off_fin = 152.931 uV 12:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.430 uVs 12:56:08 Integrated Voltage Measurement... 12:56:17 Voltage Offset Correction: v_off_ini = 165.463 uV, v_off_fin = 178.540 uV 12:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.371 uVs 12:56:17 Integrated Voltage Measurement... 12:56:26 Voltage Offset Correction: v_off_ini = 159.817 uV, v_off_fin = 146.898 uV 12:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.636 uVs 12:56:26 Integrated Voltage Measurement... 12:56:35 Voltage Offset Correction: v_off_ini = 149.047 uV, v_off_fin = 154.582 uV 12:56:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.843 uVs 12:56:39 I1Y Average and RMS of Measurements VT = -266.736 +- 7.370 uVs I1Y = -53.347 +- 1.474 uTm 12:56:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:56:47 Integrated Voltage Measurement... 12:56:56 Voltage Offset Correction: v_off_ini = 172.656 uV, v_off_fin = 158.050 uV 12:56:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.214 uVs 12:56:56 Integrated Voltage Measurement... 12:57:05 Voltage Offset Correction: v_off_ini = 166.405 uV, v_off_fin = 170.375 uV 12:57:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.057 uVs 12:57:05 Integrated Voltage Measurement... 12:57:14 Voltage Offset Correction: v_off_ini = 169.372 uV, v_off_fin = 160.970 uV 12:57:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.947 uVs 12:57:14 Integrated Voltage Measurement... 12:57:23 Voltage Offset Correction: v_off_ini = 159.107 uV, v_off_fin = 174.114 uV 12:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.623 uVs 12:57:23 Integrated Voltage Measurement... 12:57:32 Voltage Offset Correction: v_off_ini = 155.344 uV, v_off_fin = 155.742 uV 12:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.029 uVs 12:57:32 Integrated Voltage Measurement... 12:57:41 Voltage Offset Correction: v_off_ini = 164.833 uV, v_off_fin = 158.805 uV 12:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.802 uVs 12:57:43 I2X Average and RMS of Measurements VT = -92.112 +- 7.965 uVs I2X = 8.474 +- 0.733 uTm^2 12:57:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:57:51 Integrated Voltage Measurement... 12:58:00 Voltage Offset Correction: v_off_ini = 144.096 uV, v_off_fin = 152.814 uV 12:58:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.027 uVs 12:58:00 Integrated Voltage Measurement... 12:58:09 Voltage Offset Correction: v_off_ini = 158.880 uV, v_off_fin = 158.968 uV 12:58:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.904 uVs 12:58:09 Integrated Voltage Measurement... 12:58:18 Voltage Offset Correction: v_off_ini = 161.380 uV, v_off_fin = 178.151 uV 12:58:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.783 uVs 12:58:18 Integrated Voltage Measurement... 12:58:27 Voltage Offset Correction: v_off_ini = 178.666 uV, v_off_fin = 173.604 uV 12:58:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.213 uVs 12:58:27 Integrated Voltage Measurement... 12:58:36 Voltage Offset Correction: v_off_ini = 172.276 uV, v_off_fin = 179.299 uV 12:58:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.966 uVs 12:58:36 Integrated Voltage Measurement... 12:58:45 Voltage Offset Correction: v_off_ini = 166.701 uV, v_off_fin = 171.639 uV 12:58:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 332.194 uVs 12:58:48 I2Y Average and RMS of Measurements VT = -323.181 +- 0.664 uVs I2Y = -29.733 +- 0.062 uTm^2 12:58:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:58:57 Integrated Voltage Measurement... 12:59:06 Voltage Offset Correction: v_off_ini = 154.709 uV, v_off_fin = 161.101 uV 12:59:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.814 uVs 12:59:06 Integrated Voltage Measurement... 12:59:15 Voltage Offset Correction: v_off_ini = 141.868 uV, v_off_fin = 159.810 uV 12:59:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.612 uVs 12:59:15 Integrated Voltage Measurement... 12:59:24 Voltage Offset Correction: v_off_ini = 167.876 uV, v_off_fin = 167.235 uV 12:59:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.888 uVs 12:59:24 Integrated Voltage Measurement... 12:59:33 Voltage Offset Correction: v_off_ini = 161.471 uV, v_off_fin = 168.752 uV 12:59:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.782 uVs 12:59:33 Integrated Voltage Measurement... 12:59:42 Voltage Offset Correction: v_off_ini = 166.756 uV, v_off_fin = 163.812 uV 12:59:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.521 uVs 12:59:42 Integrated Voltage Measurement... 12:59:51 Voltage Offset Correction: v_off_ini = 185.465 uV, v_off_fin = 160.884 uV 12:59:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.475 uVs 12:59:55 I1X Average and RMS of Measurements VT = -72.515 +- 4.655 uVs I1X = 14.503 +- 0.931 uTm 12:59:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:00:02 Integrated Voltage Measurement... 13:00:11 Voltage Offset Correction: v_off_ini = 155.751 uV, v_off_fin = 138.393 uV 13:00:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.607 uVs 13:00:11 Integrated Voltage Measurement... 13:00:20 Voltage Offset Correction: v_off_ini = 146.850 uV, v_off_fin = 164.993 uV 13:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.919 uVs 13:00:20 Integrated Voltage Measurement... 13:00:29 Voltage Offset Correction: v_off_ini = 147.223 uV, v_off_fin = 131.233 uV 13:00:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.923 uVs 13:00:29 Integrated Voltage Measurement... 13:00:38 Voltage Offset Correction: v_off_ini = 148.230 uV, v_off_fin = 158.456 uV 13:00:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.670 uVs 13:00:38 Integrated Voltage Measurement... 13:00:47 Voltage Offset Correction: v_off_ini = 143.162 uV, v_off_fin = 128.579 uV 13:00:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.453 uVs 13:00:47 Integrated Voltage Measurement... 13:00:56 Voltage Offset Correction: v_off_ini = 143.812 uV, v_off_fin = 158.410 uV 13:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.120 uVs 13:01:00 I1Y Average and RMS of Measurements VT = -266.782 +- 4.623 uVs I1Y = -53.356 +- 0.925 uTm 13:01:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:01:07 Integrated Voltage Measurement... 13:01:16 Voltage Offset Correction: v_off_ini = 149.731 uV, v_off_fin = 137.572 uV 13:01:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.974 uVs 13:01:17 Integrated Voltage Measurement... 13:01:25 Voltage Offset Correction: v_off_ini = 143.932 uV, v_off_fin = 149.637 uV 13:01:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.733 uVs 13:01:26 Integrated Voltage Measurement... 13:01:35 Voltage Offset Correction: v_off_ini = 149.806 uV, v_off_fin = 136.848 uV 13:01:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.584 uVs 13:01:35 Integrated Voltage Measurement... 13:01:44 Voltage Offset Correction: v_off_ini = 137.322 uV, v_off_fin = 144.998 uV 13:01:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.843 uVs 13:01:44 Integrated Voltage Measurement... 13:01:53 Voltage Offset Correction: v_off_ini = 146.673 uV, v_off_fin = 124.089 uV 13:01:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.539 uVs 13:01:53 Integrated Voltage Measurement... 13:02:02 Voltage Offset Correction: v_off_ini = 130.055 uV, v_off_fin = 139.203 uV 13:02:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.671 uVs 13:02:04 I2X Average and RMS of Measurements VT = -105.224 +- 1.690 uVs I2X = 9.681 +- 0.155 uTm^2 13:02:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:02:12 Integrated Voltage Measurement... 13:02:21 Voltage Offset Correction: v_off_ini = 131.257 uV, v_off_fin = 134.267 uV 13:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.455 uVs 13:02:21 Integrated Voltage Measurement... 13:02:30 Voltage Offset Correction: v_off_ini = 139.320 uV, v_off_fin = 151.277 uV 13:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.333 uVs 13:02:30 Integrated Voltage Measurement... 13:02:39 Voltage Offset Correction: v_off_ini = 126.575 uV, v_off_fin = 127.906 uV 13:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.957 uVs 13:02:39 Integrated Voltage Measurement... 13:02:48 Voltage Offset Correction: v_off_ini = 139.675 uV, v_off_fin = 130.372 uV 13:02:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.094 uVs 13:02:48 Integrated Voltage Measurement... 13:02:57 Voltage Offset Correction: v_off_ini = 135.888 uV, v_off_fin = 146.906 uV 13:02:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.040 uVs 13:02:57 Integrated Voltage Measurement... 13:03:06 Voltage Offset Correction: v_off_ini = 140.236 uV, v_off_fin = 148.592 uV 13:03:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.735 uVs 13:03:08 I2Y Average and RMS of Measurements VT = -327.602 +- 4.527 uVs I2Y = -30.139 +- 0.417 uTm^2 13:03:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:17 Integrated Voltage Measurement... 13:03:26 Voltage Offset Correction: v_off_ini = 180.663 uV, v_off_fin = 168.434 uV 13:03:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.463 uVs 13:03:26 Integrated Voltage Measurement... 13:03:35 Voltage Offset Correction: v_off_ini = 158.759 uV, v_off_fin = 164.436 uV 13:03:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.188 uVs 13:03:35 Integrated Voltage Measurement... 13:03:44 Voltage Offset Correction: v_off_ini = 158.867 uV, v_off_fin = 133.820 uV 13:03:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.253 uVs 13:03:44 Integrated Voltage Measurement... 13:03:53 Voltage Offset Correction: v_off_ini = 143.508 uV, v_off_fin = 136.643 uV 13:03:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.112 uVs 13:03:53 Integrated Voltage Measurement... 13:04:02 Voltage Offset Correction: v_off_ini = 143.724 uV, v_off_fin = 143.142 uV 13:04:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.627 uVs 13:04:02 Integrated Voltage Measurement... 13:04:11 Voltage Offset Correction: v_off_ini = 138.017 uV, v_off_fin = 132.973 uV 13:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.061 uVs 13:04:16 I1X Average and RMS of Measurements VT = -81.617 +- 8.442 uVs I1X = 16.323 +- 1.688 uTm 13:04:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:04:22 Integrated Voltage Measurement... 13:04:31 Voltage Offset Correction: v_off_ini = 154.930 uV, v_off_fin = 148.714 uV 13:04:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.774 uVs 13:04:31 Integrated Voltage Measurement... 13:04:40 Voltage Offset Correction: v_off_ini = 168.242 uV, v_off_fin = 172.991 uV 13:04:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.085 uVs 13:04:40 Integrated Voltage Measurement... 13:04:49 Voltage Offset Correction: v_off_ini = 158.206 uV, v_off_fin = 147.081 uV 13:04:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.561 uVs 13:04:49 Integrated Voltage Measurement... 13:04:58 Voltage Offset Correction: v_off_ini = 167.994 uV, v_off_fin = 172.164 uV 13:04:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.942 uVs 13:04:58 Integrated Voltage Measurement... 13:05:07 Voltage Offset Correction: v_off_ini = 174.513 uV, v_off_fin = 154.310 uV 13:05:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.022 uVs 13:05:07 Integrated Voltage Measurement... 13:05:16 Voltage Offset Correction: v_off_ini = 156.021 uV, v_off_fin = 169.855 uV 13:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.838 uVs 13:05:20 I1Y Average and RMS of Measurements VT = -262.704 +- 7.325 uVs I1Y = -52.541 +- 1.465 uTm 13:05:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:28 Integrated Voltage Measurement... 13:05:37 Voltage Offset Correction: v_off_ini = 160.870 uV, v_off_fin = 158.289 uV 13:05:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.896 uVs 13:05:37 Integrated Voltage Measurement... 13:05:46 Voltage Offset Correction: v_off_ini = 160.017 uV, v_off_fin = 158.902 uV 13:05:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.729 uVs 13:05:46 Integrated Voltage Measurement... 13:05:55 Voltage Offset Correction: v_off_ini = 159.763 uV, v_off_fin = 145.593 uV 13:05:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.945 uVs 13:05:55 Integrated Voltage Measurement... 13:06:04 Voltage Offset Correction: v_off_ini = 163.229 uV, v_off_fin = 165.658 uV 13:06:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.637 uVs 13:06:04 Integrated Voltage Measurement... 13:06:13 Voltage Offset Correction: v_off_ini = 146.930 uV, v_off_fin = 145.998 uV 13:06:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.538 uVs 13:06:13 Integrated Voltage Measurement... 13:06:22 Voltage Offset Correction: v_off_ini = 146.142 uV, v_off_fin = 163.873 uV 13:06:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.729 uVs 13:06:25 I2X Average and RMS of Measurements VT = -95.579 +- 4.254 uVs I2X = 8.794 +- 0.392 uTm^2 13:06:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:33 Integrated Voltage Measurement... 13:06:42 Voltage Offset Correction: v_off_ini = 158.617 uV, v_off_fin = 151.730 uV 13:06:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.593 uVs 13:06:42 Integrated Voltage Measurement... 13:06:51 Voltage Offset Correction: v_off_ini = 164.551 uV, v_off_fin = 170.136 uV 13:06:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.877 uVs 13:06:51 Integrated Voltage Measurement... 13:07:00 Voltage Offset Correction: v_off_ini = 168.937 uV, v_off_fin = 146.567 uV 13:07:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.154 uVs 13:07:00 Integrated Voltage Measurement... 13:07:09 Voltage Offset Correction: v_off_ini = 141.862 uV, v_off_fin = 150.931 uV 13:07:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.697 uVs 13:07:09 Integrated Voltage Measurement... 13:07:18 Voltage Offset Correction: v_off_ini = 144.330 uV, v_off_fin = 148.119 uV 13:07:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.944 uVs 13:07:18 Integrated Voltage Measurement... 13:07:27 Voltage Offset Correction: v_off_ini = 153.157 uV, v_off_fin = 144.892 uV 13:07:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.181 uVs 13:07:29 I2Y Average and RMS of Measurements VT = -324.908 +- 4.981 uVs I2Y = -29.891 +- 0.458 uTm^2 13:07:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:07:38 Integrated Voltage Measurement... 13:07:47 Voltage Offset Correction: v_off_ini = 149.089 uV, v_off_fin = 150.110 uV 13:07:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.006 uVs 13:07:47 Integrated Voltage Measurement... 13:07:56 Voltage Offset Correction: v_off_ini = 159.690 uV, v_off_fin = 164.417 uV 13:07:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.112 uVs 13:07:56 Integrated Voltage Measurement... 13:08:05 Voltage Offset Correction: v_off_ini = 167.022 uV, v_off_fin = 156.120 uV 13:08:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.341 uVs 13:08:05 Integrated Voltage Measurement... 13:08:14 Voltage Offset Correction: v_off_ini = 155.230 uV, v_off_fin = 162.672 uV 13:08:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.544 uVs 13:08:14 Integrated Voltage Measurement... 13:08:23 Voltage Offset Correction: v_off_ini = 155.926 uV, v_off_fin = 160.257 uV 13:08:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.475 uVs 13:08:23 Integrated Voltage Measurement... 13:08:32 Voltage Offset Correction: v_off_ini = 169.516 uV, v_off_fin = 174.130 uV 13:08:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.196 uVs 13:08:36 I1X Average and RMS of Measurements VT = -77.445 +- 1.863 uVs I1X = 15.489 +- 0.373 uTm 13:08:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:08:43 Integrated Voltage Measurement... 13:08:52 Voltage Offset Correction: v_off_ini = 152.808 uV, v_off_fin = 140.912 uV 13:08:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.546 uVs 13:08:52 Integrated Voltage Measurement... 13:09:01 Voltage Offset Correction: v_off_ini = 154.062 uV, v_off_fin = 177.116 uV 13:09:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.187 uVs 13:09:01 Integrated Voltage Measurement... 13:09:10 Voltage Offset Correction: v_off_ini = 162.562 uV, v_off_fin = 162.575 uV 13:09:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.126 uVs 13:09:10 Integrated Voltage Measurement... 13:09:19 Voltage Offset Correction: v_off_ini = 167.419 uV, v_off_fin = 167.675 uV 13:09:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.708 uVs 13:09:19 Integrated Voltage Measurement... 13:09:28 Voltage Offset Correction: v_off_ini = 175.542 uV, v_off_fin = 165.260 uV 13:09:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -278.596 uVs 13:09:28 Integrated Voltage Measurement... 13:09:37 Voltage Offset Correction: v_off_ini = 161.010 uV, v_off_fin = 172.208 uV 13:09:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.848 uVs 13:09:41 I1Y Average and RMS of Measurements VT = -279.669 +- 0.767 uVs I1Y = -55.934 +- 0.153 uTm 13:09:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:09:49 Integrated Voltage Measurement... 13:09:58 Voltage Offset Correction: v_off_ini = 162.297 uV, v_off_fin = 156.481 uV 13:09:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.045 uVs 13:09:58 Integrated Voltage Measurement... 13:10:07 Voltage Offset Correction: v_off_ini = 151.025 uV, v_off_fin = 167.376 uV 13:10:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.954 uVs 13:10:07 Integrated Voltage Measurement... 13:10:16 Voltage Offset Correction: v_off_ini = 163.296 uV, v_off_fin = 160.722 uV 13:10:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.105 uVs 13:10:16 Integrated Voltage Measurement... 13:10:25 Voltage Offset Correction: v_off_ini = 168.067 uV, v_off_fin = 175.332 uV 13:10:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.856 uVs 13:10:25 Integrated Voltage Measurement... 13:10:34 Voltage Offset Correction: v_off_ini = 164.370 uV, v_off_fin = 168.138 uV 13:10:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.188 uVs 13:10:34 Integrated Voltage Measurement... 13:10:43 Voltage Offset Correction: v_off_ini = 169.674 uV, v_off_fin = 179.568 uV 13:10:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.473 uVs 13:10:46 I2X Average and RMS of Measurements VT = -95.270 +- 4.103 uVs I2X = 8.765 +- 0.378 uTm^2 13:10:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:10:53 Integrated Voltage Measurement... 13:11:02 Voltage Offset Correction: v_off_ini = 174.654 uV, v_off_fin = 174.168 uV 13:11:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.902 uVs 13:11:02 Integrated Voltage Measurement... 13:11:11 Voltage Offset Correction: v_off_ini = 179.868 uV, v_off_fin = 180.981 uV 13:11:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.049 uVs 13:11:11 Integrated Voltage Measurement... 13:11:20 Voltage Offset Correction: v_off_ini = 173.192 uV, v_off_fin = 175.293 uV 13:11:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.733 uVs 13:11:21 Integrated Voltage Measurement... 13:11:29 Voltage Offset Correction: v_off_ini = 171.921 uV, v_off_fin = 167.864 uV 13:11:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.701 uVs 13:11:30 Integrated Voltage Measurement... 13:11:39 Voltage Offset Correction: v_off_ini = 159.085 uV, v_off_fin = 157.502 uV 13:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.150 uVs 13:11:39 Integrated Voltage Measurement... 13:11:48 Voltage Offset Correction: v_off_ini = 171.236 uV, v_off_fin = 171.783 uV 13:11:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.242 uVs 13:11:50 I2Y Average and RMS of Measurements VT = -333.630 +- 5.078 uVs I2Y = -30.694 +- 0.467 uTm^2 13:11:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:11:59 Integrated Voltage Measurement... 13:12:08 Voltage Offset Correction: v_off_ini = 187.780 uV, v_off_fin = 179.101 uV 13:12:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.746 uVs 13:12:08 Integrated Voltage Measurement... 13:12:17 Voltage Offset Correction: v_off_ini = 177.309 uV, v_off_fin = 178.088 uV 13:12:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.836 uVs 13:12:17 Integrated Voltage Measurement... 13:12:26 Voltage Offset Correction: v_off_ini = 169.645 uV, v_off_fin = 171.644 uV 13:12:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.609 uVs 13:12:26 Integrated Voltage Measurement... 13:12:35 Voltage Offset Correction: v_off_ini = 170.865 uV, v_off_fin = 170.727 uV 13:12:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.558 uVs 13:12:35 Integrated Voltage Measurement... 13:12:44 Voltage Offset Correction: v_off_ini = 157.677 uV, v_off_fin = 159.467 uV 13:12:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.495 uVs 13:12:44 Integrated Voltage Measurement... 13:12:53 Voltage Offset Correction: v_off_ini = 170.550 uV, v_off_fin = 172.472 uV 13:12:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.361 uVs 13:12:57 I1X Average and RMS of Measurements VT = -88.934 +- 6.455 uVs I1X = 17.787 +- 1.291 uTm 13:13:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:13:04 Integrated Voltage Measurement... 13:13:13 Voltage Offset Correction: v_off_ini = 171.816 uV, v_off_fin = 153.808 uV 13:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.481 uVs 13:13:13 Integrated Voltage Measurement... 13:13:22 Voltage Offset Correction: v_off_ini = 161.610 uV, v_off_fin = 163.594 uV 13:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.696 uVs 13:13:22 Integrated Voltage Measurement... 13:13:31 Voltage Offset Correction: v_off_ini = 152.887 uV, v_off_fin = 139.056 uV 13:13:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.399 uVs 13:13:31 Integrated Voltage Measurement... 13:13:40 Voltage Offset Correction: v_off_ini = 161.174 uV, v_off_fin = 161.687 uV 13:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.649 uVs 13:13:40 Integrated Voltage Measurement... 13:13:49 Voltage Offset Correction: v_off_ini = 143.830 uV, v_off_fin = 146.759 uV 13:13:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.907 uVs 13:13:49 Integrated Voltage Measurement... 13:13:58 Voltage Offset Correction: v_off_ini = 157.414 uV, v_off_fin = 155.316 uV 13:13:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.520 uVs 13:14:02 I1Y Average and RMS of Measurements VT = -258.775 +- 6.585 uVs I1Y = -51.755 +- 1.317 uTm 13:14:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:14:10 Integrated Voltage Measurement... 13:14:19 Voltage Offset Correction: v_off_ini = 152.297 uV, v_off_fin = 157.904 uV 13:14:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.577 uVs 13:14:19 Integrated Voltage Measurement... 13:14:28 Voltage Offset Correction: v_off_ini = 148.690 uV, v_off_fin = 155.522 uV 13:14:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.673 uVs 13:14:28 Integrated Voltage Measurement... 13:14:37 Voltage Offset Correction: v_off_ini = 143.944 uV, v_off_fin = 136.170 uV 13:14:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.239 uVs 13:14:37 Integrated Voltage Measurement... 13:14:46 Voltage Offset Correction: v_off_ini = 140.125 uV, v_off_fin = 153.828 uV 13:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.814 uVs 13:14:46 Integrated Voltage Measurement... 13:14:55 Voltage Offset Correction: v_off_ini = 143.395 uV, v_off_fin = 138.049 uV 13:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.067 uVs 13:14:55 Integrated Voltage Measurement... 13:15:04 Voltage Offset Correction: v_off_ini = 148.425 uV, v_off_fin = 153.897 uV 13:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.353 uVs 13:15:07 I2X Average and RMS of Measurements VT = -95.787 +- 6.082 uVs I2X = 8.813 +- 0.560 uTm^2 13:15:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:15:14 Integrated Voltage Measurement... 13:15:23 Voltage Offset Correction: v_off_ini = 144.793 uV, v_off_fin = 127.574 uV 13:15:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.564 uVs 13:15:23 Integrated Voltage Measurement... 13:15:32 Voltage Offset Correction: v_off_ini = 124.453 uV, v_off_fin = 124.707 uV 13:15:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.404 uVs 13:15:32 Integrated Voltage Measurement... 13:15:41 Voltage Offset Correction: v_off_ini = 127.917 uV, v_off_fin = 127.791 uV 13:15:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.684 uVs 13:15:41 Integrated Voltage Measurement... 13:15:50 Voltage Offset Correction: v_off_ini = 126.291 uV, v_off_fin = 117.407 uV 13:15:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.127 uVs 13:15:50 Integrated Voltage Measurement... 13:15:59 Voltage Offset Correction: v_off_ini = 123.578 uV, v_off_fin = 122.943 uV 13:15:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.301 uVs 13:15:59 Integrated Voltage Measurement... 13:16:08 Voltage Offset Correction: v_off_ini = 143.726 uV, v_off_fin = 140.367 uV 13:16:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.062 uVs 13:16:11 I2Y Average and RMS of Measurements VT = -308.357 +- 8.316 uVs I2Y = -28.369 +- 0.765 uTm^2 13:16:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:16:23 Integrated Voltage Measurement... 13:16:32 Voltage Offset Correction: v_off_ini = 143.834 uV, v_off_fin = 132.718 uV 13:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.575 uVs 13:16:32 Integrated Voltage Measurement... 13:16:41 Voltage Offset Correction: v_off_ini = 143.287 uV, v_off_fin = 139.465 uV 13:16:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.874 uVs 13:16:41 Integrated Voltage Measurement... 13:16:50 Voltage Offset Correction: v_off_ini = 155.919 uV, v_off_fin = 134.106 uV 13:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.933 uVs 13:16:50 Integrated Voltage Measurement... 13:16:59 Voltage Offset Correction: v_off_ini = 148.337 uV, v_off_fin = 140.999 uV 13:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.207 uVs 13:16:59 Integrated Voltage Measurement... 13:17:08 Voltage Offset Correction: v_off_ini = 134.079 uV, v_off_fin = 136.554 uV 13:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.861 uVs 13:17:08 Integrated Voltage Measurement... 13:17:17 Voltage Offset Correction: v_off_ini = 128.039 uV, v_off_fin = 136.487 uV 13:17:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.609 uVs 13:17:21 I1X Average and RMS of Measurements VT = -75.010 +- 8.641 uVs I1X = 15.002 +- 1.728 uTm 13:17:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:17:28 Integrated Voltage Measurement... 13:17:37 Voltage Offset Correction: v_off_ini = 149.063 uV, v_off_fin = 122.462 uV 13:17:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.896 uVs 13:17:37 Integrated Voltage Measurement... 13:17:46 Voltage Offset Correction: v_off_ini = 139.063 uV, v_off_fin = 151.029 uV 13:17:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.256 uVs 13:17:46 Integrated Voltage Measurement... 13:17:55 Voltage Offset Correction: v_off_ini = 144.672 uV, v_off_fin = 130.450 uV 13:17:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.488 uVs 13:17:55 Integrated Voltage Measurement... 13:18:04 Voltage Offset Correction: v_off_ini = 147.099 uV, v_off_fin = 157.326 uV 13:18:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.667 uVs 13:18:04 Integrated Voltage Measurement... 13:18:13 Voltage Offset Correction: v_off_ini = 127.555 uV, v_off_fin = 136.895 uV 13:18:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.925 uVs 13:18:13 Integrated Voltage Measurement... 13:18:22 Voltage Offset Correction: v_off_ini = 151.275 uV, v_off_fin = 156.097 uV 13:18:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.278 uVs 13:18:26 I1Y Average and RMS of Measurements VT = -260.252 +- 7.037 uVs I1Y = -52.050 +- 1.407 uTm 13:18:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:18:31 Integrated Voltage Measurement... 13:18:40 Voltage Offset Correction: v_off_ini = 135.156 uV, v_off_fin = 134.673 uV 13:18:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.403 uVs 13:18:40 Integrated Voltage Measurement... 13:18:49 Voltage Offset Correction: v_off_ini = 140.181 uV, v_off_fin = 152.240 uV 13:18:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.519 uVs 13:18:50 Integrated Voltage Measurement... 13:18:58 Voltage Offset Correction: v_off_ini = 149.901 uV, v_off_fin = 129.592 uV 13:18:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.571 uVs 13:18:59 Integrated Voltage Measurement... 13:19:07 Voltage Offset Correction: v_off_ini = 145.384 uV, v_off_fin = 133.008 uV 13:19:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.841 uVs 13:19:08 Integrated Voltage Measurement... 13:19:17 Voltage Offset Correction: v_off_ini = 132.789 uV, v_off_fin = 118.100 uV 13:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.275 uVs 13:19:17 Integrated Voltage Measurement... 13:19:26 Voltage Offset Correction: v_off_ini = 129.352 uV, v_off_fin = 130.046 uV 13:19:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.368 uVs 13:19:28 I2X Average and RMS of Measurements VT = -81.663 +- 6.445 uVs I2X = 7.513 +- 0.593 uTm^2 13:19:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:19:33 Integrated Voltage Measurement... 13:19:42 Voltage Offset Correction: v_off_ini = 136.766 uV, v_off_fin = 126.018 uV 13:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.612 uVs 13:19:42 Integrated Voltage Measurement... 13:19:51 Voltage Offset Correction: v_off_ini = 131.881 uV, v_off_fin = 132.649 uV 13:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.327 uVs 13:19:51 Integrated Voltage Measurement... 13:20:00 Voltage Offset Correction: v_off_ini = 135.357 uV, v_off_fin = 132.991 uV 13:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.636 uVs 13:20:00 Integrated Voltage Measurement... 13:20:09 Voltage Offset Correction: v_off_ini = 119.213 uV, v_off_fin = 121.627 uV 13:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.746 uVs 13:20:09 Integrated Voltage Measurement... 13:20:18 Voltage Offset Correction: v_off_ini = 116.758 uV, v_off_fin = 120.988 uV 13:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.362 uVs 13:20:18 Integrated Voltage Measurement... 13:20:27 Voltage Offset Correction: v_off_ini = 125.922 uV, v_off_fin = 131.517 uV 13:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.947 uVs 13:20:30 I2Y Average and RMS of Measurements VT = -325.105 +- 10.183 uVs I2Y = -29.910 +- 0.937 uTm^2 13:20:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:20:38 Integrated Voltage Measurement... 13:20:47 Voltage Offset Correction: v_off_ini = 132.758 uV, v_off_fin = 126.413 uV 13:20:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.235 uVs 13:20:47 Integrated Voltage Measurement... 13:20:56 Voltage Offset Correction: v_off_ini = 125.878 uV, v_off_fin = 132.704 uV 13:20:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.926 uVs 13:20:56 Integrated Voltage Measurement... 13:21:05 Voltage Offset Correction: v_off_ini = 131.344 uV, v_off_fin = 119.297 uV 13:21:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.847 uVs 13:21:05 Integrated Voltage Measurement... 13:21:14 Voltage Offset Correction: v_off_ini = 119.026 uV, v_off_fin = 130.617 uV 13:21:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.798 uVs 13:21:14 Integrated Voltage Measurement... 13:21:23 Voltage Offset Correction: v_off_ini = 129.575 uV, v_off_fin = 122.520 uV 13:21:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.007 uVs 13:21:23 Integrated Voltage Measurement... 13:21:32 Voltage Offset Correction: v_off_ini = 122.957 uV, v_off_fin = 126.597 uV 13:21:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.864 uVs 13:21:36 I1X Average and RMS of Measurements VT = -73.446 +- 8.367 uVs I1X = 14.690 +- 1.674 uTm 13:21:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:21:43 Integrated Voltage Measurement... 13:21:52 Voltage Offset Correction: v_off_ini = 135.653 uV, v_off_fin = 129.526 uV 13:21:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.883 uVs 13:21:52 Integrated Voltage Measurement... 13:22:01 Voltage Offset Correction: v_off_ini = 131.019 uV, v_off_fin = 154.830 uV 13:22:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.179 uVs 13:22:01 Integrated Voltage Measurement... 13:22:10 Voltage Offset Correction: v_off_ini = 116.029 uV, v_off_fin = 113.491 uV 13:22:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.297 uVs 13:22:10 Integrated Voltage Measurement... 13:22:19 Voltage Offset Correction: v_off_ini = 126.205 uV, v_off_fin = 130.017 uV 13:22:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.939 uVs 13:22:19 Integrated Voltage Measurement... 13:22:28 Voltage Offset Correction: v_off_ini = 130.768 uV, v_off_fin = 114.561 uV 13:22:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.537 uVs 13:22:28 Integrated Voltage Measurement... 13:22:37 Voltage Offset Correction: v_off_ini = 120.583 uV, v_off_fin = 138.801 uV 13:22:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.629 uVs 13:22:41 I1Y Average and RMS of Measurements VT = -271.911 +- 4.100 uVs I1Y = -54.382 +- 0.820 uTm 13:22:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:22:47 Integrated Voltage Measurement... 13:22:56 Voltage Offset Correction: v_off_ini = 133.740 uV, v_off_fin = 125.925 uV 13:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.323 uVs 13:22:56 Integrated Voltage Measurement... 13:23:05 Voltage Offset Correction: v_off_ini = 138.281 uV, v_off_fin = 149.379 uV 13:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.652 uVs 13:23:05 Integrated Voltage Measurement... 13:23:14 Voltage Offset Correction: v_off_ini = 136.403 uV, v_off_fin = 128.498 uV 13:23:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.999 uVs 13:23:14 Integrated Voltage Measurement... 13:23:23 Voltage Offset Correction: v_off_ini = 125.233 uV, v_off_fin = 144.727 uV 13:23:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.654 uVs 13:23:23 Integrated Voltage Measurement... 13:23:32 Voltage Offset Correction: v_off_ini = 142.773 uV, v_off_fin = 135.061 uV 13:23:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.067 uVs 13:23:32 Integrated Voltage Measurement... 13:23:41 Voltage Offset Correction: v_off_ini = 134.939 uV, v_off_fin = 129.256 uV 13:23:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.860 uVs 13:23:43 I2X Average and RMS of Measurements VT = -92.759 +- 2.435 uVs I2X = 8.534 +- 0.224 uTm^2 13:23:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:23:48 Integrated Voltage Measurement... 13:23:57 Voltage Offset Correction: v_off_ini = 127.327 uV, v_off_fin = 137.440 uV 13:23:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.584 uVs 13:23:57 Integrated Voltage Measurement... 13:24:06 Voltage Offset Correction: v_off_ini = 157.251 uV, v_off_fin = 150.865 uV 13:24:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.821 uVs 13:24:06 Integrated Voltage Measurement... 13:24:15 Voltage Offset Correction: v_off_ini = 143.654 uV, v_off_fin = 142.754 uV 13:24:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.857 uVs 13:24:16 Integrated Voltage Measurement... 13:24:24 Voltage Offset Correction: v_off_ini = 157.690 uV, v_off_fin = 150.785 uV 13:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.719 uVs 13:24:25 Integrated Voltage Measurement... 13:24:34 Voltage Offset Correction: v_off_ini = 153.518 uV, v_off_fin = 141.308 uV 13:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.755 uVs 13:24:34 Integrated Voltage Measurement... 13:24:43 Voltage Offset Correction: v_off_ini = 138.714 uV, v_off_fin = 139.126 uV 13:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.430 uVs 13:24:45 I2Y Average and RMS of Measurements VT = -322.694 +- 2.703 uVs I2Y = -29.688 +- 0.249 uTm^2 13:24:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:53 Integrated Voltage Measurement... 13:25:02 Voltage Offset Correction: v_off_ini = 129.623 uV, v_off_fin = 125.878 uV 13:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.254 uVs 13:25:02 Integrated Voltage Measurement... 13:25:11 Voltage Offset Correction: v_off_ini = 138.170 uV, v_off_fin = 140.117 uV 13:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.254 uVs 13:25:11 Integrated Voltage Measurement... 13:25:20 Voltage Offset Correction: v_off_ini = 129.067 uV, v_off_fin = 114.068 uV 13:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.611 uVs 13:25:20 Integrated Voltage Measurement... 13:25:29 Voltage Offset Correction: v_off_ini = 121.940 uV, v_off_fin = 133.077 uV 13:25:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.267 uVs 13:25:29 Integrated Voltage Measurement... 13:25:38 Voltage Offset Correction: v_off_ini = 129.547 uV, v_off_fin = 131.877 uV 13:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.616 uVs 13:25:38 Integrated Voltage Measurement... 13:25:47 Voltage Offset Correction: v_off_ini = 136.899 uV, v_off_fin = 147.640 uV 13:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.845 uVs 13:25:52 I1X Average and RMS of Measurements VT = -76.141 +- 7.308 uVs I1X = 15.228 +- 1.462 uTm 13:25:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:58 Integrated Voltage Measurement... 13:26:07 Voltage Offset Correction: v_off_ini = 149.369 uV, v_off_fin = 144.458 uV 13:26:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.105 uVs 13:26:07 Integrated Voltage Measurement... 13:26:16 Voltage Offset Correction: v_off_ini = 137.533 uV, v_off_fin = 156.322 uV 13:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.813 uVs 13:26:16 Integrated Voltage Measurement... 13:26:25 Voltage Offset Correction: v_off_ini = 145.606 uV, v_off_fin = 138.384 uV 13:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.856 uVs 13:26:25 Integrated Voltage Measurement... 13:26:34 Voltage Offset Correction: v_off_ini = 144.220 uV, v_off_fin = 155.887 uV 13:26:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.766 uVs 13:26:34 Integrated Voltage Measurement... 13:26:43 Voltage Offset Correction: v_off_ini = 145.480 uV, v_off_fin = 129.582 uV 13:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.214 uVs 13:26:43 Integrated Voltage Measurement... 13:26:52 Voltage Offset Correction: v_off_ini = 133.039 uV, v_off_fin = 161.303 uV 13:26:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.694 uVs 13:26:56 I1Y Average and RMS of Measurements VT = -261.741 +- 2.371 uVs I1Y = -52.348 +- 0.474 uTm 13:26:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:02 Integrated Voltage Measurement... 13:27:11 Voltage Offset Correction: v_off_ini = 141.064 uV, v_off_fin = 119.916 uV 13:27:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.431 uVs 13:27:11 Integrated Voltage Measurement... 13:27:20 Voltage Offset Correction: v_off_ini = 134.297 uV, v_off_fin = 135.831 uV 13:27:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.856 uVs 13:27:20 Integrated Voltage Measurement... 13:27:29 Voltage Offset Correction: v_off_ini = 131.270 uV, v_off_fin = 123.078 uV 13:27:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.255 uVs 13:27:29 Integrated Voltage Measurement... 13:27:38 Voltage Offset Correction: v_off_ini = 136.559 uV, v_off_fin = 150.621 uV 13:27:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.950 uVs 13:27:38 Integrated Voltage Measurement... 13:27:47 Voltage Offset Correction: v_off_ini = 136.925 uV, v_off_fin = 125.220 uV 13:27:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.088 uVs 13:27:47 Integrated Voltage Measurement... 13:27:56 Voltage Offset Correction: v_off_ini = 123.046 uV, v_off_fin = 145.287 uV 13:27:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.277 uVs 13:27:58 I2X Average and RMS of Measurements VT = -91.643 +- 2.863 uVs I2X = 8.431 +- 0.263 uTm^2 13:28:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:03 Integrated Voltage Measurement... 13:28:12 Voltage Offset Correction: v_off_ini = 134.098 uV, v_off_fin = 133.029 uV 13:28:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -319.353 uVs 13:28:12 Integrated Voltage Measurement... 13:28:21 Voltage Offset Correction: v_off_ini = 131.531 uV, v_off_fin = 133.393 uV 13:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.264 uVs 13:28:21 Integrated Voltage Measurement... 13:28:30 Voltage Offset Correction: v_off_ini = 134.239 uV, v_off_fin = 127.290 uV 13:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.607 uVs 13:28:30 Integrated Voltage Measurement... 13:28:39 Voltage Offset Correction: v_off_ini = 123.285 uV, v_off_fin = 133.770 uV 13:28:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.468 uVs 13:28:39 Integrated Voltage Measurement... 13:28:48 Voltage Offset Correction: v_off_ini = 126.819 uV, v_off_fin = 110.490 uV 13:28:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.653 uVs 13:28:48 Integrated Voltage Measurement... 13:28:57 Voltage Offset Correction: v_off_ini = 116.980 uV, v_off_fin = 125.022 uV 13:28:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.744 uVs 13:29:00 I2Y Average and RMS of Measurements VT = -327.515 +- 2.789 uVs I2Y = -30.132 +- 0.256 uTm^2 13:29:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:29:08 Integrated Voltage Measurement... 13:29:17 Voltage Offset Correction: v_off_ini = 123.494 uV, v_off_fin = 131.154 uV 13:29:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.334 uVs 13:29:17 Integrated Voltage Measurement... 13:29:26 Voltage Offset Correction: v_off_ini = 127.354 uV, v_off_fin = 141.763 uV 13:29:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4998 mm VT = 70.555 uVs 13:29:26 Integrated Voltage Measurement... 13:29:35 Voltage Offset Correction: v_off_ini = 142.987 uV, v_off_fin = 132.556 uV 13:29:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.678 uVs 13:29:35 Integrated Voltage Measurement... 13:29:44 Voltage Offset Correction: v_off_ini = 132.759 uV, v_off_fin = 136.014 uV 13:29:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.791 uVs 13:29:44 Integrated Voltage Measurement... 13:29:53 Voltage Offset Correction: v_off_ini = 139.286 uV, v_off_fin = 124.192 uV 13:29:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.922 uVs 13:29:53 Integrated Voltage Measurement... 13:30:02 Voltage Offset Correction: v_off_ini = 128.063 uV, v_off_fin = 126.108 uV 13:30:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.883 uVs 13:30:06 I1X Average and RMS of Measurements VT = -76.027 +- 5.362 uVs I1X = 15.207 +- 1.071 uTm 13:30:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:30:13 Integrated Voltage Measurement... 13:30:22 Voltage Offset Correction: v_off_ini = 127.807 uV, v_off_fin = 104.960 uV 13:30:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -265.613 uVs 13:30:22 Integrated Voltage Measurement... 13:30:31 Voltage Offset Correction: v_off_ini = 118.636 uV, v_off_fin = 131.421 uV 13:30:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 265.242 uVs 13:30:31 Integrated Voltage Measurement... 13:30:40 Voltage Offset Correction: v_off_ini = 134.166 uV, v_off_fin = 120.100 uV 13:30:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.753 uVs 13:30:40 Integrated Voltage Measurement... 13:30:49 Voltage Offset Correction: v_off_ini = 110.368 uV, v_off_fin = 125.765 uV 13:30:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.317 uVs 13:30:49 Integrated Voltage Measurement... 13:30:58 Voltage Offset Correction: v_off_ini = 117.828 uV, v_off_fin = 101.210 uV 13:30:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.288 uVs 13:30:58 Integrated Voltage Measurement... 13:31:07 Voltage Offset Correction: v_off_ini = 112.148 uV, v_off_fin = 110.363 uV 13:31:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.492 uVs 13:31:11 I1Y Average and RMS of Measurements VT = -267.618 +- 1.644 uVs I1Y = -53.524 +- 0.329 uTm 13:31:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:31:16 Integrated Voltage Measurement... 13:31:25 Voltage Offset Correction: v_off_ini = 123.251 uV, v_off_fin = 128.930 uV 13:31:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.222 uVs 13:31:25 Integrated Voltage Measurement... 13:31:34 Voltage Offset Correction: v_off_ini = 139.481 uV, v_off_fin = 132.413 uV 13:31:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.499 uVs 13:31:34 Integrated Voltage Measurement... 13:31:43 Voltage Offset Correction: v_off_ini = 116.940 uV, v_off_fin = 97.254 uV 13:31:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.211 uVs 13:31:43 Integrated Voltage Measurement... 13:31:52 Voltage Offset Correction: v_off_ini = 125.856 uV, v_off_fin = 116.913 uV 13:31:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.329 uVs 13:31:53 Integrated Voltage Measurement... 13:32:01 Voltage Offset Correction: v_off_ini = 125.932 uV, v_off_fin = 114.846 uV 13:32:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.778 uVs 13:32:02 Integrated Voltage Measurement... 13:32:11 Voltage Offset Correction: v_off_ini = 121.630 uV, v_off_fin = 120.791 uV 13:32:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.379 uVs 13:32:13 I2X Average and RMS of Measurements VT = -91.570 +- 3.430 uVs I2X = 8.424 +- 0.316 uTm^2 13:32:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:32:18 Integrated Voltage Measurement... 13:32:27 Voltage Offset Correction: v_off_ini = 137.126 uV, v_off_fin = 129.933 uV 13:32:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.550 uVs 13:32:27 Integrated Voltage Measurement... 13:32:36 Voltage Offset Correction: v_off_ini = 124.228 uV, v_off_fin = 123.493 uV 13:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.595 uVs 13:32:36 Integrated Voltage Measurement... 13:32:45 Voltage Offset Correction: v_off_ini = 115.570 uV, v_off_fin = 124.083 uV 13:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.707 uVs 13:32:45 Integrated Voltage Measurement... 13:32:54 Voltage Offset Correction: v_off_ini = 116.971 uV, v_off_fin = 116.124 uV 13:32:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.883 uVs 13:32:54 Integrated Voltage Measurement... 13:33:03 Voltage Offset Correction: v_off_ini = 114.738 uV, v_off_fin = 126.352 uV 13:33:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.980 uVs 13:33:03 Integrated Voltage Measurement... 13:33:12 Voltage Offset Correction: v_off_ini = 119.202 uV, v_off_fin = 115.774 uV 13:33:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.830 uVs 13:33:15 I2Y Average and RMS of Measurements VT = -321.924 +- 5.792 uVs I2Y = -29.617 +- 0.533 uTm^2 13:33:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:33:23 Integrated Voltage Measurement... 13:33:32 Voltage Offset Correction: v_off_ini = 97.392 uV, v_off_fin = 97.635 uV 13:33:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.209 uVs 13:33:32 Integrated Voltage Measurement... 13:33:41 Voltage Offset Correction: v_off_ini = 103.329 uV, v_off_fin = 96.736 uV 13:33:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.550 uVs 13:33:41 Integrated Voltage Measurement... 13:33:50 Voltage Offset Correction: v_off_ini = 84.866 uV, v_off_fin = 89.776 uV 13:33:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.284 uVs 13:33:50 Integrated Voltage Measurement... 13:33:59 Voltage Offset Correction: v_off_ini = 93.766 uV, v_off_fin = 92.684 uV 13:33:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.841 uVs 13:33:59 Integrated Voltage Measurement... 13:34:08 Voltage Offset Correction: v_off_ini = 97.486 uV, v_off_fin = 93.838 uV 13:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.474 uVs 13:34:08 Integrated Voltage Measurement... 13:34:17 Voltage Offset Correction: v_off_ini = 93.384 uV, v_off_fin = 103.222 uV 13:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.730 uVs 13:34:21 I1X Average and RMS of Measurements VT = -64.348 +- 2.160 uVs I1X = 12.870 +- 0.432 uTm 13:34:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:34:28 Integrated Voltage Measurement... 13:34:37 Voltage Offset Correction: v_off_ini = 87.261 uV, v_off_fin = 77.757 uV 13:34:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.976 uVs 13:34:37 Integrated Voltage Measurement... 13:34:46 Voltage Offset Correction: v_off_ini = 112.385 uV, v_off_fin = 132.389 uV 13:34:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.568 uVs 13:34:46 Integrated Voltage Measurement... 13:34:55 Voltage Offset Correction: v_off_ini = 116.959 uV, v_off_fin = 114.449 uV 13:34:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.483 uVs 13:34:55 Integrated Voltage Measurement... 13:35:04 Voltage Offset Correction: v_off_ini = 106.584 uV, v_off_fin = 118.537 uV 13:35:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.326 uVs 13:35:04 Integrated Voltage Measurement... 13:35:13 Voltage Offset Correction: v_off_ini = 102.663 uV, v_off_fin = 90.738 uV 13:35:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.695 uVs 13:35:13 Integrated Voltage Measurement... 13:35:22 Voltage Offset Correction: v_off_ini = 89.714 uV, v_off_fin = 104.432 uV 13:35:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.406 uVs 13:35:26 I1Y Average and RMS of Measurements VT = -258.909 +- 6.429 uVs I1Y = -51.781 +- 1.286 uTm 13:35:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:35:31 Integrated Voltage Measurement... 13:35:40 Voltage Offset Correction: v_off_ini = 67.178 uV, v_off_fin = 79.673 uV 13:35:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.176 uVs 13:35:40 Integrated Voltage Measurement... 13:35:49 Voltage Offset Correction: v_off_ini = 78.126 uV, v_off_fin = 96.361 uV 13:35:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.236 uVs 13:35:49 Integrated Voltage Measurement... 13:35:58 Voltage Offset Correction: v_off_ini = 74.937 uV, v_off_fin = 81.248 uV 13:35:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.641 uVs 13:35:58 Integrated Voltage Measurement... 13:36:07 Voltage Offset Correction: v_off_ini = 93.993 uV, v_off_fin = 107.424 uV 13:36:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.318 uVs 13:36:07 Integrated Voltage Measurement... 13:36:16 Voltage Offset Correction: v_off_ini = 96.751 uV, v_off_fin = 92.943 uV 13:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.804 uVs 13:36:16 Integrated Voltage Measurement... 13:36:25 Voltage Offset Correction: v_off_ini = 97.333 uV, v_off_fin = 100.285 uV 13:36:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.582 uVs 13:36:28 I2X Average and RMS of Measurements VT = -84.293 +- 6.305 uVs I2X = 7.755 +- 0.580 uTm^2 13:36:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:36:33 Integrated Voltage Measurement... 13:36:42 Voltage Offset Correction: v_off_ini = 102.688 uV, v_off_fin = 98.408 uV 13:36:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.540 uVs 13:36:42 Integrated Voltage Measurement... 13:36:51 Voltage Offset Correction: v_off_ini = 90.168 uV, v_off_fin = 96.518 uV 13:36:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.656 uVs 13:36:51 Integrated Voltage Measurement... 13:37:00 Voltage Offset Correction: v_off_ini = 92.422 uV, v_off_fin = 100.561 uV 13:37:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.338 uVs 13:37:00 Integrated Voltage Measurement... 13:37:09 Voltage Offset Correction: v_off_ini = 96.077 uV, v_off_fin = 109.626 uV 13:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.902 uVs 13:37:09 Integrated Voltage Measurement... 13:37:18 Voltage Offset Correction: v_off_ini = 99.037 uV, v_off_fin = 102.817 uV 13:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.713 uVs 13:37:18 Integrated Voltage Measurement... 13:37:27 Voltage Offset Correction: v_off_ini = 113.174 uV, v_off_fin = 98.941 uV 13:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.806 uVs 13:37:29 I2Y Average and RMS of Measurements VT = -322.826 +- 4.660 uVs I2Y = -29.700 +- 0.429 uTm^2 13:38:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:38:05 Integrated Voltage Measurement... 13:38:14 Voltage Offset Correction: v_off_ini = 109.866 uV, v_off_fin = 93.402 uV 13:38:14 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -71.650 uVs 13:38:14 Integrated Voltage Measurement... 13:38:23 Voltage Offset Correction: v_off_ini = 84.710 uV, v_off_fin = 107.032 uV 13:38:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 68.978 uVs 13:38:23 Integrated Voltage Measurement... 13:38:32 Voltage Offset Correction: v_off_ini = 105.594 uV, v_off_fin = 96.342 uV 13:38:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.810 uVs 13:38:32 Integrated Voltage Measurement... 13:38:41 Voltage Offset Correction: v_off_ini = 96.334 uV, v_off_fin = 91.731 uV 13:38:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.129 uVs 13:38:41 Integrated Voltage Measurement... 13:38:50 Voltage Offset Correction: v_off_ini = 98.707 uV, v_off_fin = 101.551 uV 13:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.802 uVs 13:38:50 Integrated Voltage Measurement... 13:38:59 Voltage Offset Correction: v_off_ini = 100.436 uV, v_off_fin = 94.127 uV 13:38:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.499 uVs 13:39:03 I1X Average and RMS of Measurements VT = -71.811 +- 2.601 uVs I1X = 14.364 +- 0.519 uTm 13:39:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:39:10 Integrated Voltage Measurement... 13:39:19 Voltage Offset Correction: v_off_ini = 89.095 uV, v_off_fin = 88.456 uV 13:39:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -214.766 uVs 13:39:19 Integrated Voltage Measurement... 13:39:28 Voltage Offset Correction: v_off_ini = 82.977 uV, v_off_fin = 93.227 uV 13:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.694 uVs 13:39:28 Integrated Voltage Measurement... 13:39:37 Voltage Offset Correction: v_off_ini = 93.401 uV, v_off_fin = 77.489 uV 13:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.270 uVs 13:39:37 Integrated Voltage Measurement... 13:39:46 Voltage Offset Correction: v_off_ini = 89.055 uV, v_off_fin = 85.158 uV 13:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.308 uVs 13:39:46 Integrated Voltage Measurement... 13:39:55 Voltage Offset Correction: v_off_ini = 88.563 uV, v_off_fin = 79.996 uV 13:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.847 uVs 13:39:55 Integrated Voltage Measurement... 13:40:04 Voltage Offset Correction: v_off_ini = 84.695 uV, v_off_fin = 96.528 uV 13:40:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.371 uVs 13:40:08 I1Y Average and RMS of Measurements VT = -213.543 +- 3.135 uVs I1Y = -42.711 +- 0.629 uTm 13:40:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:40:16 Integrated Voltage Measurement... 13:40:25 Voltage Offset Correction: v_off_ini = 91.187 uV, v_off_fin = 76.209 uV 13:40:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.559 uVs 13:40:25 Integrated Voltage Measurement... 13:40:34 Voltage Offset Correction: v_off_ini = 88.338 uV, v_off_fin = 98.123 uV 13:40:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.403 uVs 13:40:34 Integrated Voltage Measurement... 13:40:43 Voltage Offset Correction: v_off_ini = 83.718 uV, v_off_fin = 78.755 uV 13:40:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.642 uVs 13:40:43 Integrated Voltage Measurement... 13:40:52 Voltage Offset Correction: v_off_ini = 87.375 uV, v_off_fin = 106.403 uV 13:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.199 uVs 13:40:52 Integrated Voltage Measurement... 13:41:01 Voltage Offset Correction: v_off_ini = 85.816 uV, v_off_fin = 73.265 uV 13:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.094 uVs 13:41:01 Integrated Voltage Measurement... 13:41:10 Voltage Offset Correction: v_off_ini = 94.799 uV, v_off_fin = 105.373 uV 13:41:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.362 uVs 13:41:12 I2X Average and RMS of Measurements VT = -66.877 +- 5.216 uVs I2X = 6.153 +- 0.480 uTm^2 13:41:17 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:41:20 Integrated Voltage Measurement... 13:41:29 Voltage Offset Correction: v_off_ini = 92.136 uV, v_off_fin = 75.426 uV 13:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.800 uVs 13:41:29 Integrated Voltage Measurement... 13:41:38 Voltage Offset Correction: v_off_ini = 56.881 uV, v_off_fin = 67.437 uV 13:41:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.435 uVs 13:41:38 Integrated Voltage Measurement... 13:41:47 Voltage Offset Correction: v_off_ini = 80.698 uV, v_off_fin = 67.804 uV 13:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.044 uVs 13:41:47 Integrated Voltage Measurement... 13:41:56 Voltage Offset Correction: v_off_ini = 68.003 uV, v_off_fin = 68.692 uV 13:41:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.525 uVs 13:41:56 Integrated Voltage Measurement... 13:42:05 Voltage Offset Correction: v_off_ini = 64.729 uV, v_off_fin = 56.412 uV 13:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.988 uVs 13:42:05 Integrated Voltage Measurement... 13:42:14 Voltage Offset Correction: v_off_ini = 77.012 uV, v_off_fin = 69.969 uV 13:42:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.338 uVs 13:42:17 I2Y Average and RMS of Measurements VT = -240.188 +- 2.245 uVs I2Y = -22.097 +- 0.207 uTm^2 13:42:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:42:25 Integrated Voltage Measurement... 13:42:34 Voltage Offset Correction: v_off_ini = 81.194 uV, v_off_fin = 56.784 uV 13:42:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.075 uVs 13:42:35 Integrated Voltage Measurement... 13:42:43 Voltage Offset Correction: v_off_ini = 86.531 uV, v_off_fin = 86.584 uV 13:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.141 uVs 13:42:44 Integrated Voltage Measurement... 13:42:52 Voltage Offset Correction: v_off_ini = 84.862 uV, v_off_fin = 69.476 uV 13:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.058 uVs 13:42:53 Integrated Voltage Measurement... 13:43:02 Voltage Offset Correction: v_off_ini = 75.663 uV, v_off_fin = 57.407 uV 13:43:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.033 uVs 13:43:02 Integrated Voltage Measurement... 13:43:11 Voltage Offset Correction: v_off_ini = 67.470 uV, v_off_fin = 50.938 uV 13:43:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.772 uVs 13:43:11 Integrated Voltage Measurement... 13:43:20 Voltage Offset Correction: v_off_ini = 73.629 uV, v_off_fin = 72.180 uV 13:43:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.900 uVs 13:43:24 I1X Average and RMS of Measurements VT = -64.663 +- 5.467 uVs I1X = 12.933 +- 1.093 uTm 13:43:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:43:31 Integrated Voltage Measurement... 13:43:40 Voltage Offset Correction: v_off_ini = 57.690 uV, v_off_fin = 51.779 uV 13:43:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.446 uVs 13:43:40 Integrated Voltage Measurement... 13:43:49 Voltage Offset Correction: v_off_ini = 59.964 uV, v_off_fin = 64.432 uV 13:43:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.032 uVs 13:43:49 Integrated Voltage Measurement... 13:43:58 Voltage Offset Correction: v_off_ini = 62.149 uV, v_off_fin = 51.711 uV 13:43:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.560 uVs 13:43:58 Integrated Voltage Measurement... 13:44:07 Voltage Offset Correction: v_off_ini = 42.889 uV, v_off_fin = 67.968 uV 13:44:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.554 uVs 13:44:07 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = 61.411 uV, v_off_fin = 45.950 uV 13:44:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.777 uVs 13:44:16 Integrated Voltage Measurement... 13:44:25 Voltage Offset Correction: v_off_ini = 57.753 uV, v_off_fin = 58.195 uV 13:44:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.880 uVs 13:44:29 I1Y Average and RMS of Measurements VT = -220.208 +- 5.099 uVs I1Y = -44.042 +- 1.020 uTm 13:44:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:44:36 Integrated Voltage Measurement... 13:44:45 Voltage Offset Correction: v_off_ini = 54.633 uV, v_off_fin = 48.087 uV 13:44:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.955 uVs 13:44:46 Integrated Voltage Measurement... 13:44:55 Voltage Offset Correction: v_off_ini = 59.218 uV, v_off_fin = 72.072 uV 13:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.317 uVs 13:44:55 Integrated Voltage Measurement... 13:45:04 Voltage Offset Correction: v_off_ini = 54.772 uV, v_off_fin = 36.249 uV 13:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.505 uVs 13:45:04 Integrated Voltage Measurement... 13:45:13 Voltage Offset Correction: v_off_ini = 41.532 uV, v_off_fin = 50.565 uV 13:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.281 uVs 13:45:13 Integrated Voltage Measurement... 13:45:22 Voltage Offset Correction: v_off_ini = 50.365 uV, v_off_fin = 38.853 uV 13:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.227 uVs 13:45:22 Integrated Voltage Measurement... 13:45:31 Voltage Offset Correction: v_off_ini = 37.923 uV, v_off_fin = 57.268 uV 13:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.857 uVs 13:45:33 I2X Average and RMS of Measurements VT = -78.190 +- 6.030 uVs I2X = 7.194 +- 0.555 uTm^2 13:45:38 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:45:41 Integrated Voltage Measurement... 13:45:50 Voltage Offset Correction: v_off_ini = 45.793 uV, v_off_fin = 46.718 uV 13:45:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.929 uVs 13:45:50 Integrated Voltage Measurement... 13:45:59 Voltage Offset Correction: v_off_ini = 62.381 uV, v_off_fin = 55.392 uV 13:45:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.339 uVs 13:45:59 Integrated Voltage Measurement... 13:46:08 Voltage Offset Correction: v_off_ini = 56.242 uV, v_off_fin = 53.152 uV 13:46:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.486 uVs 13:46:08 Integrated Voltage Measurement... 13:46:17 Voltage Offset Correction: v_off_ini = 53.728 uV, v_off_fin = 51.253 uV 13:46:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.396 uVs 13:46:17 Integrated Voltage Measurement... 13:46:26 Voltage Offset Correction: v_off_ini = 49.543 uV, v_off_fin = 36.404 uV 13:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.540 uVs 13:46:26 Integrated Voltage Measurement... 13:46:35 Voltage Offset Correction: v_off_ini = 33.269 uV, v_off_fin = 32.880 uV 13:46:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.027 uVs 13:46:37 I2Y Average and RMS of Measurements VT = -245.119 +- 3.454 uVs I2Y = -22.551 +- 0.318 uTm^2 13:46:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:46 Integrated Voltage Measurement... 13:46:55 Voltage Offset Correction: v_off_ini = 53.169 uV, v_off_fin = 33.682 uV 13:46:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.309 uVs 13:46:55 Integrated Voltage Measurement... 13:47:04 Voltage Offset Correction: v_off_ini = 37.988 uV, v_off_fin = 44.805 uV 13:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.265 uVs 13:47:04 Integrated Voltage Measurement... 13:47:13 Voltage Offset Correction: v_off_ini = 35.238 uV, v_off_fin = 34.543 uV 13:47:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.511 uVs 13:47:13 Integrated Voltage Measurement... 13:47:22 Voltage Offset Correction: v_off_ini = 13.899 uV, v_off_fin = 34.199 uV 13:47:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.354 uVs 13:47:22 Integrated Voltage Measurement... 13:47:31 Voltage Offset Correction: v_off_ini = 29.652 uV, v_off_fin = 21.904 uV 13:47:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -55.556 uVs 13:47:31 Integrated Voltage Measurement... 13:47:40 Voltage Offset Correction: v_off_ini = 26.559 uV, v_off_fin = 35.902 uV 13:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.995 uVs 13:47:45 I1X Average and RMS of Measurements VT = -70.665 +- 7.263 uVs I1X = 14.133 +- 1.452 uTm 13:47:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:51 Integrated Voltage Measurement... 13:48:00 Voltage Offset Correction: v_off_ini = 32.202 uV, v_off_fin = 31.934 uV 13:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.197 uVs 13:48:00 Integrated Voltage Measurement... 13:48:09 Voltage Offset Correction: v_off_ini = 36.897 uV, v_off_fin = 44.547 uV 13:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.288 uVs 13:48:09 Integrated Voltage Measurement... 13:48:18 Voltage Offset Correction: v_off_ini = 48.299 uV, v_off_fin = 40.651 uV 13:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.908 uVs 13:48:19 Integrated Voltage Measurement... 13:48:27 Voltage Offset Correction: v_off_ini = 55.294 uV, v_off_fin = 41.407 uV 13:48:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.005 uVs 13:48:28 Integrated Voltage Measurement... 13:48:36 Voltage Offset Correction: v_off_ini = 30.689 uV, v_off_fin = 27.322 uV 13:48:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.918 uVs 13:48:37 Integrated Voltage Measurement... 13:48:45 Voltage Offset Correction: v_off_ini = 31.966 uV, v_off_fin = 49.361 uV 13:48:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.821 uVs 13:48:50 I1Y Average and RMS of Measurements VT = -211.856 +- 3.574 uVs I1Y = -42.371 +- 0.715 uTm 13:48:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:57 Integrated Voltage Measurement... 13:49:06 Voltage Offset Correction: v_off_ini = 23.253 uV, v_off_fin = 20.739 uV 13:49:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -45.922 uVs 13:49:06 Integrated Voltage Measurement... 13:49:15 Voltage Offset Correction: v_off_ini = 28.178 uV, v_off_fin = 34.548 uV 13:49:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.849 uVs 13:49:15 Integrated Voltage Measurement... 13:49:24 Voltage Offset Correction: v_off_ini = 29.375 uV, v_off_fin = 24.119 uV 13:49:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.471 uVs 13:49:25 Integrated Voltage Measurement... 13:49:33 Voltage Offset Correction: v_off_ini = 33.671 uV, v_off_fin = 30.378 uV 13:49:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.686 uVs 13:49:34 Integrated Voltage Measurement... 13:49:43 Voltage Offset Correction: v_off_ini = 19.341 uV, v_off_fin = 3.030 uV 13:49:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.421 uVs 13:49:43 Integrated Voltage Measurement... 13:49:52 Voltage Offset Correction: v_off_ini = 12.419 uV, v_off_fin = 32.221 uV 13:49:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.692 uVs 13:49:54 I2X Average and RMS of Measurements VT = -74.340 +- 13.950 uVs I2X = 6.839 +- 1.283 uTm^2 13:49:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:02 Integrated Voltage Measurement... 13:50:11 Voltage Offset Correction: v_off_ini = 20.854 uV, v_off_fin = 21.561 uV 13:50:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.879 uVs 13:50:11 Integrated Voltage Measurement... 13:50:20 Voltage Offset Correction: v_off_ini = 15.193 uV, v_off_fin = 14.085 uV 13:50:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.795 uVs 13:50:20 Integrated Voltage Measurement... 13:50:29 Voltage Offset Correction: v_off_ini = 23.673 uV, v_off_fin = 23.730 uV 13:50:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.658 uVs 13:50:29 Integrated Voltage Measurement... 13:50:38 Voltage Offset Correction: v_off_ini = 0.428 uV, v_off_fin = 2.053 uV 13:50:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.961 uVs 13:50:38 Integrated Voltage Measurement... 13:50:47 Voltage Offset Correction: v_off_ini = 9.596 uV, v_off_fin = 7.907 uV 13:50:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.008 uVs 13:50:47 Integrated Voltage Measurement... 13:50:56 Voltage Offset Correction: v_off_ini = 9.441 uV, v_off_fin = 11.788 uV 13:50:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.511 uVs 13:50:58 I2Y Average and RMS of Measurements VT = -237.469 +- 3.552 uVs I2Y = -21.847 +- 0.327 uTm^2 13:51:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:51:07 Integrated Voltage Measurement... 13:51:16 Voltage Offset Correction: v_off_ini = 10.151 uV, v_off_fin = -14.688 uV 13:51:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.322 uVs 13:51:16 Integrated Voltage Measurement... 13:51:25 Voltage Offset Correction: v_off_ini = 1.786 uV, v_off_fin = 6.199 uV 13:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.207 uVs 13:51:25 Integrated Voltage Measurement... 13:51:34 Voltage Offset Correction: v_off_ini = 10.662 uV, v_off_fin = 3.083 uV 13:51:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.914 uVs 13:51:34 Integrated Voltage Measurement... 13:51:43 Voltage Offset Correction: v_off_ini = 9.154 uV, v_off_fin = 17.978 uV 13:51:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.836 uVs 13:51:43 Integrated Voltage Measurement... 13:51:52 Voltage Offset Correction: v_off_ini = 22.376 uV, v_off_fin = 21.971 uV 13:51:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.569 uVs 13:51:52 Integrated Voltage Measurement... 13:52:01 Voltage Offset Correction: v_off_ini = 13.781 uV, v_off_fin = 20.922 uV 13:52:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.892 uVs 13:52:06 I1X Average and RMS of Measurements VT = -80.290 +- 9.435 uVs I1X = 16.058 +- 1.887 uTm 13:52:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:52:12 Integrated Voltage Measurement... 13:52:21 Voltage Offset Correction: v_off_ini = 1.926 uV, v_off_fin = 1.040 uV 13:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.968 uVs 13:52:21 Integrated Voltage Measurement... 13:52:30 Voltage Offset Correction: v_off_ini = 6.522 uV, v_off_fin = 27.795 uV 13:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.919 uVs 13:52:30 Integrated Voltage Measurement... 13:52:39 Voltage Offset Correction: v_off_ini = 12.895 uV, v_off_fin = 0.958 uV 13:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.656 uVs 13:52:39 Integrated Voltage Measurement... 13:52:48 Voltage Offset Correction: v_off_ini = 7.409 uV, v_off_fin = 22.891 uV 13:52:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.299 uVs 13:52:48 Integrated Voltage Measurement... 13:52:57 Voltage Offset Correction: v_off_ini = 1.726 uV, v_off_fin = -3.419 uV 13:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.367 uVs 13:52:57 Integrated Voltage Measurement... 13:53:06 Voltage Offset Correction: v_off_ini = 12.207 uV, v_off_fin = 14.772 uV 13:53:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.357 uVs 13:53:11 I1Y Average and RMS of Measurements VT = -221.761 +- 1.009 uVs I1Y = -44.352 +- 0.202 uTm 13:53:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:53:18 Integrated Voltage Measurement... 13:53:27 Voltage Offset Correction: v_off_ini = 3.969 uV, v_off_fin = -15.563 uV 13:53:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.424 uVs 13:53:27 Integrated Voltage Measurement... 13:53:36 Voltage Offset Correction: v_off_ini = 10.360 uV, v_off_fin = 7.049 uV 13:53:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.346 uVs 13:53:36 Integrated Voltage Measurement... 13:53:45 Voltage Offset Correction: v_off_ini = -4.340 uV, v_off_fin = 3.141 uV 13:53:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.387 uVs 13:53:45 Integrated Voltage Measurement... 13:53:54 Voltage Offset Correction: v_off_ini = 24.387 uV, v_off_fin = 15.667 uV 13:53:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.146 uVs 13:53:54 Integrated Voltage Measurement... 13:54:03 Voltage Offset Correction: v_off_ini = 3.986 uV, v_off_fin = 2.730 uV 13:54:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.617 uVs 13:54:03 Integrated Voltage Measurement... 13:54:12 Voltage Offset Correction: v_off_ini = 15.613 uV, v_off_fin = 22.289 uV 13:54:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.080 uVs 13:54:15 I2X Average and RMS of Measurements VT = -66.500 +- 7.326 uVs I2X = 6.118 +- 0.674 uTm^2 13:54:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:54:23 Integrated Voltage Measurement... 13:54:32 Voltage Offset Correction: v_off_ini = 19.593 uV, v_off_fin = 19.443 uV 13:54:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.448 uVs 13:54:32 Integrated Voltage Measurement... 13:54:41 Voltage Offset Correction: v_off_ini = 16.323 uV, v_off_fin = 26.426 uV 13:54:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.509 uVs 13:54:41 Integrated Voltage Measurement... 13:54:50 Voltage Offset Correction: v_off_ini = 26.832 uV, v_off_fin = 32.497 uV 13:54:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.559 uVs 13:54:50 Integrated Voltage Measurement... 13:54:59 Voltage Offset Correction: v_off_ini = 12.175 uV, v_off_fin = 15.284 uV 13:54:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.474 uVs 13:54:59 Integrated Voltage Measurement... 13:55:08 Voltage Offset Correction: v_off_ini = 16.677 uV, v_off_fin = 14.895 uV 13:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.447 uVs 13:55:08 Integrated Voltage Measurement... 13:55:17 Voltage Offset Correction: v_off_ini = 15.941 uV, v_off_fin = 19.679 uV 13:55:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.604 uVs 13:55:19 I2Y Average and RMS of Measurements VT = -242.340 +- 0.852 uVs I2Y = -22.295 +- 0.078 uTm^2 13:55:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:55:28 Integrated Voltage Measurement... 13:55:37 Voltage Offset Correction: v_off_ini = 27.611 uV, v_off_fin = 17.550 uV 13:55:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.103 uVs 13:55:37 Integrated Voltage Measurement... 13:55:46 Voltage Offset Correction: v_off_ini = 23.649 uV, v_off_fin = 19.115 uV 13:55:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.462 uVs 13:55:46 Integrated Voltage Measurement... 13:55:55 Voltage Offset Correction: v_off_ini = 7.155 uV, v_off_fin = 7.368 uV 13:55:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.256 uVs 13:55:55 Integrated Voltage Measurement... 13:56:04 Voltage Offset Correction: v_off_ini = 14.608 uV, v_off_fin = 9.842 uV 13:56:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.015 uVs 13:56:04 Integrated Voltage Measurement... 13:56:13 Voltage Offset Correction: v_off_ini = 7.989 uV, v_off_fin = 12.155 uV 13:56:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.806 uVs 13:56:13 Integrated Voltage Measurement... 13:56:22 Voltage Offset Correction: v_off_ini = 3.714 uV, v_off_fin = 7.340 uV 13:56:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.187 uVs 13:56:26 I1X Average and RMS of Measurements VT = -72.638 +- 5.985 uVs I1X = 14.528 +- 1.197 uTm 13:56:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:56:33 Integrated Voltage Measurement... 13:56:42 Voltage Offset Correction: v_off_ini = -5.125 uV, v_off_fin = -11.949 uV 13:56:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.328 uVs 13:56:42 Integrated Voltage Measurement... 13:56:51 Voltage Offset Correction: v_off_ini = -9.613 uV, v_off_fin = 15.024 uV 13:56:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.783 uVs 13:56:51 Integrated Voltage Measurement... 13:57:00 Voltage Offset Correction: v_off_ini = 11.010 uV, v_off_fin = -0.480 uV 13:57:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.591 uVs 13:57:00 Integrated Voltage Measurement... 13:57:09 Voltage Offset Correction: v_off_ini = 3.311 uV, v_off_fin = 2.978 uV 13:57:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.573 uVs 13:57:09 Integrated Voltage Measurement... 13:57:18 Voltage Offset Correction: v_off_ini = -0.792 uV, v_off_fin = -4.622 uV 13:57:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.620 uVs 13:57:18 Integrated Voltage Measurement... 13:57:27 Voltage Offset Correction: v_off_ini = 4.342 uV, v_off_fin = 8.236 uV 13:57:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.122 uVs 13:57:31 I1Y Average and RMS of Measurements VT = -218.003 +- 1.936 uVs I1Y = -43.601 +- 0.387 uTm 13:57:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:57:39 Integrated Voltage Measurement... 13:57:48 Voltage Offset Correction: v_off_ini = -21.658 uV, v_off_fin = -26.512 uV 13:57:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.456 uVs 13:57:48 Integrated Voltage Measurement... 13:57:57 Voltage Offset Correction: v_off_ini = 4.605 uV, v_off_fin = 4.648 uV 13:57:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 56.290 uVs 13:57:57 Integrated Voltage Measurement... 13:58:06 Voltage Offset Correction: v_off_ini = -7.776 uV, v_off_fin = -24.115 uV 13:58:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.446 uVs 13:58:06 Integrated Voltage Measurement... 13:58:15 Voltage Offset Correction: v_off_ini = -13.113 uV, v_off_fin = -14.358 uV 13:58:15 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 47.173 uVs 13:58:15 Integrated Voltage Measurement... 13:58:24 Voltage Offset Correction: v_off_ini = -15.346 uV, v_off_fin = -30.412 uV 13:58:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.242 uVs 13:58:24 Integrated Voltage Measurement... 13:58:33 Voltage Offset Correction: v_off_ini = -17.303 uV, v_off_fin = -12.117 uV 13:58:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.423 uVs 13:58:36 I2X Average and RMS of Measurements VT = -67.838 +- 6.541 uVs I2X = 6.242 +- 0.602 uTm^2 13:58:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:58:43 Integrated Voltage Measurement... 13:58:52 Voltage Offset Correction: v_off_ini = -23.767 uV, v_off_fin = -17.029 uV 13:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.054 uVs 13:58:52 Integrated Voltage Measurement... 13:59:01 Voltage Offset Correction: v_off_ini = -15.342 uV, v_off_fin = -16.130 uV 13:59:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.607 uVs 13:59:02 Integrated Voltage Measurement... 13:59:10 Voltage Offset Correction: v_off_ini = -15.137 uV, v_off_fin = -4.832 uV 13:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.141 uVs 13:59:11 Integrated Voltage Measurement... 13:59:20 Voltage Offset Correction: v_off_ini = 2.177 uV, v_off_fin = -4.078 uV 13:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.579 uVs 13:59:20 Integrated Voltage Measurement... 13:59:29 Voltage Offset Correction: v_off_ini = -17.882 uV, v_off_fin = -4.562 uV 13:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.267 uVs 13:59:29 Integrated Voltage Measurement... 13:59:38 Voltage Offset Correction: v_off_ini = -1.513 uV, v_off_fin = -8.281 uV 13:59:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.533 uVs 13:59:40 I2Y Average and RMS of Measurements VT = -234.030 +- 3.897 uVs I2Y = -21.531 +- 0.359 uTm^2 13:59:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:59:52 Integrated Voltage Measurement... 14:00:01 Voltage Offset Correction: v_off_ini = -4.276 uV, v_off_fin = -0.677 uV 14:00:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.897 uVs 14:00:01 Integrated Voltage Measurement... 14:00:10 Voltage Offset Correction: v_off_ini = 0.473 uV, v_off_fin = 17.245 uV 14:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 56.366 uVs 14:00:10 Integrated Voltage Measurement... 14:00:19 Voltage Offset Correction: v_off_ini = 3.629 uV, v_off_fin = 2.281 uV 14:00:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.095 uVs 14:00:19 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = 15.816 uV, v_off_fin = 12.030 uV 14:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.296 uVs 14:00:28 Integrated Voltage Measurement... 14:00:37 Voltage Offset Correction: v_off_ini = 4.476 uV, v_off_fin = -0.027 uV 14:00:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -51.927 uVs 14:00:37 Integrated Voltage Measurement... 14:00:46 Voltage Offset Correction: v_off_ini = -15.947 uV, v_off_fin = -11.791 uV 14:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.562 uVs 14:00:50 I1X Average and RMS of Measurements VT = -59.857 +- 8.686 uVs I1X = 11.973 +- 1.738 uTm 14:00:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:00:57 Integrated Voltage Measurement... 14:01:06 Voltage Offset Correction: v_off_ini = -8.459 uV, v_off_fin = -14.697 uV 14:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.460 uVs 14:01:06 Integrated Voltage Measurement... 14:01:15 Voltage Offset Correction: v_off_ini = -10.861 uV, v_off_fin = 3.961 uV 14:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.317 uVs 14:01:15 Integrated Voltage Measurement... 14:01:24 Voltage Offset Correction: v_off_ini = -13.824 uV, v_off_fin = -21.097 uV 14:01:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.018 uVs 14:01:24 Integrated Voltage Measurement... 14:01:33 Voltage Offset Correction: v_off_ini = 2.637 uV, v_off_fin = 10.931 uV 14:01:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.243 uVs 14:01:33 Integrated Voltage Measurement... 14:01:42 Voltage Offset Correction: v_off_ini = 4.503 uV, v_off_fin = -14.121 uV 14:01:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.300 uVs 14:01:42 Integrated Voltage Measurement... 14:01:51 Voltage Offset Correction: v_off_ini = 2.394 uV, v_off_fin = 22.169 uV 14:01:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.342 uVs 14:01:55 I1Y Average and RMS of Measurements VT = -215.447 +- 2.027 uVs I1Y = -43.089 +- 0.405 uTm 14:01:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:02:00 Integrated Voltage Measurement... 14:02:09 Voltage Offset Correction: v_off_ini = -23.798 uV, v_off_fin = -16.591 uV 14:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.392 uVs 14:02:10 Integrated Voltage Measurement... 14:02:19 Voltage Offset Correction: v_off_ini = -5.901 uV, v_off_fin = -13.388 uV 14:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.508 uVs 14:02:19 Integrated Voltage Measurement... 14:02:28 Voltage Offset Correction: v_off_ini = -19.354 uV, v_off_fin = -12.587 uV 14:02:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.266 uVs 14:02:28 Integrated Voltage Measurement... 14:02:37 Voltage Offset Correction: v_off_ini = 13.622 uV, v_off_fin = 6.643 uV 14:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.985 uVs 14:02:37 Integrated Voltage Measurement... 14:02:46 Voltage Offset Correction: v_off_ini = -18.684 uV, v_off_fin = -34.127 uV 14:02:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.193 uVs 14:02:46 Integrated Voltage Measurement... 14:02:55 Voltage Offset Correction: v_off_ini = -24.965 uV, v_off_fin = -13.639 uV 14:02:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.376 uVs 14:02:57 I2X Average and RMS of Measurements VT = -59.120 +- 2.186 uVs I2X = 5.439 +- 0.201 uTm^2 14:03:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:03:02 Integrated Voltage Measurement... 14:03:11 Voltage Offset Correction: v_off_ini = -14.611 uV, v_off_fin = -19.857 uV 14:03:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.861 uVs 14:03:11 Integrated Voltage Measurement... 14:03:20 Voltage Offset Correction: v_off_ini = -23.964 uV, v_off_fin = -7.013 uV 14:03:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.170 uVs 14:03:20 Integrated Voltage Measurement... 14:03:29 Voltage Offset Correction: v_off_ini = -25.110 uV, v_off_fin = -22.679 uV 14:03:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.392 uVs 14:03:29 Integrated Voltage Measurement... 14:03:38 Voltage Offset Correction: v_off_ini = -17.638 uV, v_off_fin = -16.565 uV 14:03:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.354 uVs 14:03:38 Integrated Voltage Measurement... 14:03:47 Voltage Offset Correction: v_off_ini = -12.188 uV, v_off_fin = -19.252 uV 14:03:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -242.370 uVs 14:03:47 Integrated Voltage Measurement... 14:03:56 Voltage Offset Correction: v_off_ini = -22.028 uV, v_off_fin = -36.814 uV 14:03:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.695 uVs 14:03:59 I2Y Average and RMS of Measurements VT = -239.307 +- 2.428 uVs I2Y = -22.017 +- 0.224 uTm^2 14:04:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:04:07 Integrated Voltage Measurement... 14:04:16 Voltage Offset Correction: v_off_ini = -7.400 uV, v_off_fin = -29.369 uV 14:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.869 uVs 14:04:16 Integrated Voltage Measurement... 14:04:25 Voltage Offset Correction: v_off_ini = -13.227 uV, v_off_fin = -10.345 uV 14:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.519 uVs 14:04:25 Integrated Voltage Measurement... 14:04:34 Voltage Offset Correction: v_off_ini = -18.310 uV, v_off_fin = -20.854 uV 14:04:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.953 uVs 14:04:34 Integrated Voltage Measurement... 14:04:43 Voltage Offset Correction: v_off_ini = -18.695 uV, v_off_fin = -5.164 uV 14:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.734 uVs 14:04:43 Integrated Voltage Measurement... 14:04:52 Voltage Offset Correction: v_off_ini = 3.296 uV, v_off_fin = -15.221 uV 14:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.398 uVs 14:04:52 Integrated Voltage Measurement... 14:05:01 Voltage Offset Correction: v_off_ini = -11.115 uV, v_off_fin = -11.554 uV 14:05:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.223 uVs 14:05:05 I1X Average and RMS of Measurements VT = -70.949 +- 7.539 uVs I1X = 14.191 +- 1.508 uTm 14:05:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:05:12 Integrated Voltage Measurement... 14:05:21 Voltage Offset Correction: v_off_ini = -18.118 uV, v_off_fin = -18.093 uV 14:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.645 uVs 14:05:21 Integrated Voltage Measurement... 14:05:30 Voltage Offset Correction: v_off_ini = 3.090 uV, v_off_fin = 6.615 uV 14:05:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.254 uVs 14:05:30 Integrated Voltage Measurement... 14:05:39 Voltage Offset Correction: v_off_ini = -1.115 uV, v_off_fin = -16.127 uV 14:05:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.218 uVs 14:05:39 Integrated Voltage Measurement... 14:05:48 Voltage Offset Correction: v_off_ini = -1.350 uV, v_off_fin = 11.591 uV 14:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.828 uVs 14:05:48 Integrated Voltage Measurement... 14:05:57 Voltage Offset Correction: v_off_ini = 4.691 uV, v_off_fin = -8.163 uV 14:05:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.600 uVs 14:05:57 Integrated Voltage Measurement... 14:06:06 Voltage Offset Correction: v_off_ini = 13.865 uV, v_off_fin = 16.786 uV 14:06:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.451 uVs 14:06:10 I1Y Average and RMS of Measurements VT = -211.499 +- 3.676 uVs I1Y = -42.300 +- 0.735 uTm 14:06:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:06:16 Integrated Voltage Measurement... 14:06:25 Voltage Offset Correction: v_off_ini = 8.882 uV, v_off_fin = -8.407 uV 14:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.211 uVs 14:06:25 Integrated Voltage Measurement... 14:06:34 Voltage Offset Correction: v_off_ini = 0.863 uV, v_off_fin = 1.825 uV 14:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.867 uVs 14:06:34 Integrated Voltage Measurement... 14:06:43 Voltage Offset Correction: v_off_ini = 4.686 uV, v_off_fin = -18.699 uV 14:06:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.780 uVs 14:06:43 Integrated Voltage Measurement... 14:06:52 Voltage Offset Correction: v_off_ini = -2.950 uV, v_off_fin = 3.717 uV 14:06:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 45.505 uVs 14:06:52 Integrated Voltage Measurement... 14:07:01 Voltage Offset Correction: v_off_ini = 2.140 uV, v_off_fin = -7.760 uV 14:07:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.226 uVs 14:07:01 Integrated Voltage Measurement... 14:07:10 Voltage Offset Correction: v_off_ini = -13.028 uV, v_off_fin = 0.343 uV 14:07:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.365 uVs 14:07:12 I2X Average and RMS of Measurements VT = -69.992 +- 5.278 uVs I2X = 6.439 +- 0.485 uTm^2 14:07:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:07:17 Integrated Voltage Measurement... 14:07:26 Voltage Offset Correction: v_off_ini = -13.282 uV, v_off_fin = -24.849 uV 14:07:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.469 uVs 14:07:26 Integrated Voltage Measurement... 14:07:35 Voltage Offset Correction: v_off_ini = -21.315 uV, v_off_fin = -21.054 uV 14:07:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.247 uVs 14:07:35 Integrated Voltage Measurement... 14:07:44 Voltage Offset Correction: v_off_ini = -28.489 uV, v_off_fin = -17.576 uV 14:07:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.856 uVs 14:07:44 Integrated Voltage Measurement... 14:07:53 Voltage Offset Correction: v_off_ini = -12.188 uV, v_off_fin = -10.917 uV 14:07:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.428 uVs 14:07:53 Integrated Voltage Measurement... 14:08:02 Voltage Offset Correction: v_off_ini = -6.935 uV, v_off_fin = -9.601 uV 14:08:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.349 uVs 14:08:03 Integrated Voltage Measurement... 14:08:12 Voltage Offset Correction: v_off_ini = -7.337 uV, v_off_fin = -18.185 uV 14:08:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.103 uVs 14:08:14 I2Y Average and RMS of Measurements VT = -233.742 +- 5.146 uVs I2Y = -21.504 +- 0.473 uTm^2 14:08:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:22 Integrated Voltage Measurement... 14:08:31 Voltage Offset Correction: v_off_ini = -7.099 uV, v_off_fin = -13.423 uV 14:08:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.612 uVs 14:08:31 Integrated Voltage Measurement... 14:08:40 Voltage Offset Correction: v_off_ini = -6.406 uV, v_off_fin = -1.835 uV 14:08:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.736 uVs 14:08:40 Integrated Voltage Measurement... 14:08:49 Voltage Offset Correction: v_off_ini = -28.804 uV, v_off_fin = -37.641 uV 14:08:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.776 uVs 14:08:49 Integrated Voltage Measurement... 14:08:58 Voltage Offset Correction: v_off_ini = -17.274 uV, v_off_fin = -16.642 uV 14:08:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.645 uVs 14:08:58 Integrated Voltage Measurement... 14:09:07 Voltage Offset Correction: v_off_ini = -7.893 uV, v_off_fin = -30.093 uV 14:09:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.719 uVs 14:09:07 Integrated Voltage Measurement... 14:09:16 Voltage Offset Correction: v_off_ini = -12.251 uV, v_off_fin = -13.941 uV 14:09:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.092 uVs 14:09:21 I1X Average and RMS of Measurements VT = -66.430 +- 2.279 uVs I1X = 13.286 +- 0.456 uTm 14:09:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:27 Integrated Voltage Measurement... 14:09:36 Voltage Offset Correction: v_off_ini = -6.379 uV, v_off_fin = -29.208 uV 14:09:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -214.331 uVs 14:09:36 Integrated Voltage Measurement... 14:09:45 Voltage Offset Correction: v_off_ini = -8.159 uV, v_off_fin = 2.154 uV 14:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.296 uVs 14:09:45 Integrated Voltage Measurement... 14:09:54 Voltage Offset Correction: v_off_ini = 6.309 uV, v_off_fin = -18.627 uV 14:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.156 uVs 14:09:54 Integrated Voltage Measurement... 14:10:03 Voltage Offset Correction: v_off_ini = -13.936 uV, v_off_fin = -7.333 uV 14:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.770 uVs 14:10:03 Integrated Voltage Measurement... 14:10:12 Voltage Offset Correction: v_off_ini = -20.472 uV, v_off_fin = -28.082 uV 14:10:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.453 uVs 14:10:12 Integrated Voltage Measurement... 14:10:21 Voltage Offset Correction: v_off_ini = -13.135 uV, v_off_fin = 1.945 uV 14:10:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.896 uVs 14:10:26 I1Y Average and RMS of Measurements VT = -215.817 +- 4.188 uVs I1Y = -43.165 +- 0.836 uTm 14:10:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:31 Integrated Voltage Measurement... 14:10:40 Voltage Offset Correction: v_off_ini = -11.336 uV, v_off_fin = -19.077 uV 14:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.909 uVs 14:10:40 Integrated Voltage Measurement... 14:10:49 Voltage Offset Correction: v_off_ini = -1.213 uV, v_off_fin = -8.503 uV 14:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.607 uVs 14:10:49 Integrated Voltage Measurement... 14:10:58 Voltage Offset Correction: v_off_ini = -25.217 uV, v_off_fin = -18.741 uV 14:10:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.479 uVs 14:10:58 Integrated Voltage Measurement... 14:11:07 Voltage Offset Correction: v_off_ini = -7.458 uV, v_off_fin = 0.252 uV 14:11:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.123 uVs 14:11:07 Integrated Voltage Measurement... 14:11:16 Voltage Offset Correction: v_off_ini = -2.163 uV, v_off_fin = -6.897 uV 14:11:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.070 uVs 14:11:16 Integrated Voltage Measurement... 14:11:25 Voltage Offset Correction: v_off_ini = -0.794 uV, v_off_fin = 1.419 uV 14:11:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.717 uVs 14:11:27 I2X Average and RMS of Measurements VT = -68.151 +- 2.523 uVs I2X = 6.270 +- 0.232 uTm^2 14:11:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:32 Integrated Voltage Measurement... 14:11:41 Voltage Offset Correction: v_off_ini = -22.585 uV, v_off_fin = -14.281 uV 14:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.892 uVs 14:11:41 Integrated Voltage Measurement... 14:11:50 Voltage Offset Correction: v_off_ini = -9.332 uV, v_off_fin = -13.780 uV 14:11:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 241.176 uVs 14:11:50 Integrated Voltage Measurement... 14:11:59 Voltage Offset Correction: v_off_ini = -14.356 uV, v_off_fin = -14.270 uV 14:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.841 uVs 14:11:59 Integrated Voltage Measurement... 14:12:08 Voltage Offset Correction: v_off_ini = -15.636 uV, v_off_fin = -19.444 uV 14:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.152 uVs 14:12:09 Integrated Voltage Measurement... 14:12:18 Voltage Offset Correction: v_off_ini = -23.364 uV, v_off_fin = -16.365 uV 14:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.009 uVs 14:12:18 Integrated Voltage Measurement... 14:12:27 Voltage Offset Correction: v_off_ini = -7.448 uV, v_off_fin = -17.860 uV 14:12:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.799 uVs 14:12:29 I2Y Average and RMS of Measurements VT = -240.478 +- 7.079 uVs I2Y = -22.124 +- 0.651 uTm^2 14:12:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:12:37 Integrated Voltage Measurement... 14:12:46 Voltage Offset Correction: v_off_ini = -13.484 uV, v_off_fin = -25.830 uV 14:12:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -56.610 uVs 14:12:46 Integrated Voltage Measurement... 14:12:55 Voltage Offset Correction: v_off_ini = -11.793 uV, v_off_fin = -5.487 uV 14:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.214 uVs 14:12:55 Integrated Voltage Measurement... 14:13:04 Voltage Offset Correction: v_off_ini = -2.831 uV, v_off_fin = 5.946 uV 14:13:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.160 uVs 14:13:04 Integrated Voltage Measurement... 14:13:13 Voltage Offset Correction: v_off_ini = 3.216 uV, v_off_fin = 6.774 uV 14:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.125 uVs 14:13:13 Integrated Voltage Measurement... 14:13:22 Voltage Offset Correction: v_off_ini = 1.597 uV, v_off_fin = -2.039 uV 14:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.549 uVs 14:13:22 Integrated Voltage Measurement... 14:13:31 Voltage Offset Correction: v_off_ini = 8.349 uV, v_off_fin = 9.510 uV 14:13:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.179 uVs 14:13:36 I1X Average and RMS of Measurements VT = -66.306 +- 4.431 uVs I1X = 13.262 +- 0.886 uTm 14:13:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:13:42 Integrated Voltage Measurement... 14:13:51 Voltage Offset Correction: v_off_ini = 17.604 uV, v_off_fin = 10.725 uV 14:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.855 uVs 14:13:51 Integrated Voltage Measurement... 14:14:00 Voltage Offset Correction: v_off_ini = 9.527 uV, v_off_fin = 22.406 uV 14:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.351 uVs 14:14:00 Integrated Voltage Measurement... 14:14:09 Voltage Offset Correction: v_off_ini = 15.525 uV, v_off_fin = 3.274 uV 14:14:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.118 uVs 14:14:09 Integrated Voltage Measurement... 14:14:18 Voltage Offset Correction: v_off_ini = 21.303 uV, v_off_fin = 17.527 uV 14:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.596 uVs 14:14:18 Integrated Voltage Measurement... 14:14:27 Voltage Offset Correction: v_off_ini = 16.747 uV, v_off_fin = 0.953 uV 14:14:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.490 uVs 14:14:27 Integrated Voltage Measurement... 14:14:36 Voltage Offset Correction: v_off_ini = 10.594 uV, v_off_fin = 15.652 uV 14:14:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.462 uVs 14:14:41 I1Y Average and RMS of Measurements VT = -213.312 +- 5.409 uVs I1Y = -42.659 +- 1.080 uTm 14:14:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:14:46 Integrated Voltage Measurement... 14:14:55 Voltage Offset Correction: v_off_ini = -3.493 uV, v_off_fin = -3.405 uV 14:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.422 uVs 14:14:55 Integrated Voltage Measurement... 14:15:04 Voltage Offset Correction: v_off_ini = -4.138 uV, v_off_fin = 9.490 uV 14:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.559 uVs 14:15:04 Integrated Voltage Measurement... 14:15:13 Voltage Offset Correction: v_off_ini = -4.653 uV, v_off_fin = -8.036 uV 14:15:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.894 uVs 14:15:13 Integrated Voltage Measurement... 14:15:22 Voltage Offset Correction: v_off_ini = 2.371 uV, v_off_fin = 8.697 uV 14:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.832 uVs 14:15:22 Integrated Voltage Measurement... 14:15:31 Voltage Offset Correction: v_off_ini = 5.999 uV, v_off_fin = -3.300 uV 14:15:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.734 uVs 14:15:31 Integrated Voltage Measurement... 14:15:40 Voltage Offset Correction: v_off_ini = 3.784 uV, v_off_fin = 12.764 uV 14:15:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.585 uVs 14:15:42 I2X Average and RMS of Measurements VT = -74.171 +- 3.816 uVs I2X = 6.824 +- 0.351 uTm^2 14:15:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:15:47 Integrated Voltage Measurement... 14:15:56 Voltage Offset Correction: v_off_ini = 24.491 uV, v_off_fin = 14.257 uV 14:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.152 uVs 14:15:56 Integrated Voltage Measurement... 14:16:05 Voltage Offset Correction: v_off_ini = 22.458 uV, v_off_fin = 10.985 uV 14:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.691 uVs 14:16:06 Integrated Voltage Measurement... 14:16:14 Voltage Offset Correction: v_off_ini = 18.572 uV, v_off_fin = 21.070 uV 14:16:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.949 uVs 14:16:15 Integrated Voltage Measurement... 14:16:24 Voltage Offset Correction: v_off_ini = 25.400 uV, v_off_fin = 23.494 uV 14:16:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.336 uVs 14:16:24 Integrated Voltage Measurement... 14:16:33 Voltage Offset Correction: v_off_ini = 7.890 uV, v_off_fin = 11.054 uV 14:16:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.675 uVs 14:16:33 Integrated Voltage Measurement... 14:16:42 Voltage Offset Correction: v_off_ini = 22.517 uV, v_off_fin = 12.772 uV 14:16:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.906 uVs 14:16:44 I2Y Average and RMS of Measurements VT = -230.285 +- 0.522 uVs I2Y = -21.186 +- 0.048 uTm^2 14:16:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:16:52 Integrated Voltage Measurement... 14:17:01 Voltage Offset Correction: v_off_ini = 19.044 uV, v_off_fin = 18.695 uV 14:17:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -62.995 uVs 14:17:01 Integrated Voltage Measurement... 14:17:10 Voltage Offset Correction: v_off_ini = 19.227 uV, v_off_fin = 17.557 uV 14:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 64.109 uVs 14:17:10 Integrated Voltage Measurement... 14:17:19 Voltage Offset Correction: v_off_ini = 21.282 uV, v_off_fin = 7.039 uV 14:17:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.736 uVs 14:17:19 Integrated Voltage Measurement... 14:17:28 Voltage Offset Correction: v_off_ini = 17.063 uV, v_off_fin = 27.793 uV 14:17:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.383 uVs 14:17:28 Integrated Voltage Measurement... 14:17:37 Voltage Offset Correction: v_off_ini = 19.143 uV, v_off_fin = 17.584 uV 14:17:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.393 uVs 14:17:37 Integrated Voltage Measurement... 14:17:46 Voltage Offset Correction: v_off_ini = 17.208 uV, v_off_fin = 22.025 uV 14:17:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.687 uVs 14:17:51 I1X Average and RMS of Measurements VT = -61.717 +- 2.586 uVs I1X = 12.344 +- 0.517 uTm 14:17:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:17:57 Integrated Voltage Measurement... 14:18:06 Voltage Offset Correction: v_off_ini = 24.267 uV, v_off_fin = 6.755 uV 14:18:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.220 uVs 14:18:06 Integrated Voltage Measurement... 14:18:15 Voltage Offset Correction: v_off_ini = 30.035 uV, v_off_fin = 25.441 uV 14:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.954 uVs 14:18:15 Integrated Voltage Measurement... 14:18:24 Voltage Offset Correction: v_off_ini = 22.043 uV, v_off_fin = 2.032 uV 14:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.715 uVs 14:18:24 Integrated Voltage Measurement... 14:18:33 Voltage Offset Correction: v_off_ini = 29.867 uV, v_off_fin = 40.825 uV 14:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.474 uVs 14:18:33 Integrated Voltage Measurement... 14:18:42 Voltage Offset Correction: v_off_ini = 16.279 uV, v_off_fin = 3.947 uV 14:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.238 uVs 14:18:42 Integrated Voltage Measurement... 14:18:51 Voltage Offset Correction: v_off_ini = 18.755 uV, v_off_fin = 35.938 uV 14:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.146 uVs 14:18:56 I1Y Average and RMS of Measurements VT = -211.125 +- 1.099 uVs I1Y = -42.225 +- 0.220 uTm 14:18:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:19:01 Integrated Voltage Measurement... 14:19:10 Voltage Offset Correction: v_off_ini = 23.283 uV, v_off_fin = 18.062 uV 14:19:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.175 uVs 14:19:10 Integrated Voltage Measurement... 14:19:19 Voltage Offset Correction: v_off_ini = 15.903 uV, v_off_fin = 22.039 uV 14:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.306 uVs 14:19:19 Integrated Voltage Measurement... 14:19:28 Voltage Offset Correction: v_off_ini = 13.154 uV, v_off_fin = 5.524 uV 14:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.021 uVs 14:19:28 Integrated Voltage Measurement... 14:19:37 Voltage Offset Correction: v_off_ini = 13.197 uV, v_off_fin = 13.405 uV 14:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.942 uVs 14:19:37 Integrated Voltage Measurement... 14:19:46 Voltage Offset Correction: v_off_ini = 15.629 uV, v_off_fin = -1.729 uV 14:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.070 uVs 14:19:46 Integrated Voltage Measurement... 14:19:55 Voltage Offset Correction: v_off_ini = -3.324 uV, v_off_fin = 15.011 uV 14:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.454 uVs 14:19:57 I2X Average and RMS of Measurements VT = -65.161 +- 4.132 uVs I2X = 5.995 +- 0.380 uTm^2 14:20:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:20:02 Integrated Voltage Measurement... 14:20:11 Voltage Offset Correction: v_off_ini = -0.167 uV, v_off_fin = 7.422 uV 14:20:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.818 uVs 14:20:11 Integrated Voltage Measurement... 14:20:20 Voltage Offset Correction: v_off_ini = 11.726 uV, v_off_fin = 17.488 uV 14:20:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.660 uVs 14:20:21 Integrated Voltage Measurement... 14:20:29 Voltage Offset Correction: v_off_ini = 10.893 uV, v_off_fin = 2.389 uV 14:20:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.276 uVs 14:20:30 Integrated Voltage Measurement... 14:20:38 Voltage Offset Correction: v_off_ini = 1.764 uV, v_off_fin = -2.432 uV 14:20:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.555 uVs 14:20:39 Integrated Voltage Measurement... 14:20:48 Voltage Offset Correction: v_off_ini = 4.838 uV, v_off_fin = -0.264 uV 14:20:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.053 uVs 14:20:48 Integrated Voltage Measurement... 14:20:57 Voltage Offset Correction: v_off_ini = -7.339 uV, v_off_fin = 5.247 uV 14:20:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.047 uVs 14:20:59 I2Y Average and RMS of Measurements VT = -234.902 +- 5.542 uVs I2Y = -21.611 +- 0.510 uTm^2 14:21:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 07:23:26 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm