SLAC Magnetic Measurements Date: 08-07-2025 Time: 15:47:15 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16342 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 15:47:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:25 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:47:27 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:47:28 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:47:30 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:47:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:52 Integrated Voltage Measurement... 15:48:01 Voltage Offset Correction: v_off_ini = 172.888 uV, v_off_fin = 151.130 uV 15:48:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.947 uVs 15:48:01 Integrated Voltage Measurement... 15:48:10 Voltage Offset Correction: v_off_ini = 165.061 uV, v_off_fin = 178.160 uV 15:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.591 uVs 15:48:10 Integrated Voltage Measurement... 15:48:19 Voltage Offset Correction: v_off_ini = 173.282 uV, v_off_fin = 173.531 uV 15:48:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.691 uVs 15:48:19 Integrated Voltage Measurement... 15:48:28 Voltage Offset Correction: v_off_ini = 173.014 uV, v_off_fin = 166.953 uV 15:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.707 uVs 15:48:28 Integrated Voltage Measurement... 15:48:37 Voltage Offset Correction: v_off_ini = 164.633 uV, v_off_fin = 179.052 uV 15:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.896 uVs 15:48:37 Integrated Voltage Measurement... 15:48:46 Voltage Offset Correction: v_off_ini = 180.467 uV, v_off_fin = 197.045 uV 15:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.828 uVs 15:48:50 I1X Average and RMS of Measurements VT = -102.443 +- 3.052 uVs I1X = 20.489 +- 0.611 uTm 15:48:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:57 Integrated Voltage Measurement... 15:49:06 Voltage Offset Correction: v_off_ini = 193.375 uV, v_off_fin = 184.678 uV 15:49:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -322.333 uVs 15:49:06 Integrated Voltage Measurement... 15:49:15 Voltage Offset Correction: v_off_ini = 194.202 uV, v_off_fin = 204.804 uV 15:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 314.085 uVs 15:49:15 Integrated Voltage Measurement... 15:49:24 Voltage Offset Correction: v_off_ini = 208.776 uV, v_off_fin = 186.217 uV 15:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -319.383 uVs 15:49:24 Integrated Voltage Measurement... 15:49:33 Voltage Offset Correction: v_off_ini = 201.866 uV, v_off_fin = 207.614 uV 15:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 330.097 uVs 15:49:33 Integrated Voltage Measurement... 15:49:42 Voltage Offset Correction: v_off_ini = 181.535 uV, v_off_fin = 167.167 uV 15:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -329.332 uVs 15:49:42 Integrated Voltage Measurement... 15:49:51 Voltage Offset Correction: v_off_ini = 187.536 uV, v_off_fin = 207.924 uV 15:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 325.891 uVs 15:49:55 I1Y Average and RMS of Measurements VT = -323.520 +- 3.934 uVs I1Y = -64.704 +- 0.787 uTm 15:50:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:03 Integrated Voltage Measurement... 15:50:12 Voltage Offset Correction: v_off_ini = 195.578 uV, v_off_fin = 178.782 uV 15:50:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.680 uVs 15:50:12 Integrated Voltage Measurement... 15:50:21 Voltage Offset Correction: v_off_ini = 192.465 uV, v_off_fin = 202.850 uV 15:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.532 uVs 15:50:21 Integrated Voltage Measurement... 15:50:30 Voltage Offset Correction: v_off_ini = 174.163 uV, v_off_fin = 169.870 uV 15:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.541 uVs 15:50:30 Integrated Voltage Measurement... 15:50:39 Voltage Offset Correction: v_off_ini = 179.627 uV, v_off_fin = 185.805 uV 15:50:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.048 uVs 15:50:39 Integrated Voltage Measurement... 15:50:48 Voltage Offset Correction: v_off_ini = 177.913 uV, v_off_fin = 172.450 uV 15:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.758 uVs 15:50:48 Integrated Voltage Measurement... 15:50:57 Voltage Offset Correction: v_off_ini = 167.822 uV, v_off_fin = 172.808 uV 15:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.192 uVs 15:51:00 I2X Average and RMS of Measurements VT = -100.459 +- 4.205 uVs I2X = 9.242 +- 0.387 uTm^2 15:51:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:08 Integrated Voltage Measurement... 15:51:16 Voltage Offset Correction: v_off_ini = 177.924 uV, v_off_fin = 183.962 uV 15:51:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -547.864 uVs 15:51:17 Integrated Voltage Measurement... 15:51:26 Voltage Offset Correction: v_off_ini = 183.295 uV, v_off_fin = 191.660 uV 15:51:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 535.640 uVs 15:51:26 Integrated Voltage Measurement... 15:51:35 Voltage Offset Correction: v_off_ini = 189.613 uV, v_off_fin = 178.364 uV 15:51:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -561.392 uVs 15:51:35 Integrated Voltage Measurement... 15:51:44 Voltage Offset Correction: v_off_ini = 173.496 uV, v_off_fin = 180.392 uV 15:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.886 uVs 15:51:44 Integrated Voltage Measurement... 15:51:53 Voltage Offset Correction: v_off_ini = 170.315 uV, v_off_fin = 155.676 uV 15:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -554.411 uVs 15:51:53 Integrated Voltage Measurement... 15:52:02 Voltage Offset Correction: v_off_ini = 161.320 uV, v_off_fin = 168.250 uV 15:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 563.583 uVs 15:52:04 I2Y Average and RMS of Measurements VT = -545.630 +- 9.726 uVs I2Y = -50.198 +- 0.895 uTm^2 15:52:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:19 Integrated Voltage Measurement... 15:52:28 Voltage Offset Correction: v_off_ini = 159.151 uV, v_off_fin = 159.296 uV 15:52:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.285 uVs 15:52:28 Integrated Voltage Measurement... 15:52:37 Voltage Offset Correction: v_off_ini = 145.800 uV, v_off_fin = 171.931 uV 15:52:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 119.440 uVs 15:52:37 Integrated Voltage Measurement... 15:52:46 Voltage Offset Correction: v_off_ini = 180.305 uV, v_off_fin = 171.945 uV 15:52:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.223 uVs 15:52:46 Integrated Voltage Measurement... 15:52:55 Voltage Offset Correction: v_off_ini = 173.546 uV, v_off_fin = 170.317 uV 15:52:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.467 uVs 15:52:55 Integrated Voltage Measurement... 15:53:04 Voltage Offset Correction: v_off_ini = 174.191 uV, v_off_fin = 172.931 uV 15:53:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.241 uVs 15:53:04 Integrated Voltage Measurement... 15:53:13 Voltage Offset Correction: v_off_ini = 176.551 uV, v_off_fin = 181.914 uV 15:53:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.772 uVs 15:53:17 I1X Average and RMS of Measurements VT = -117.571 +- 5.602 uVs I1X = 23.517 +- 1.119 uTm 15:53:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:24 Integrated Voltage Measurement... 15:53:33 Voltage Offset Correction: v_off_ini = 155.518 uV, v_off_fin = 139.612 uV 15:53:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -294.835 uVs 15:53:33 Integrated Voltage Measurement... 15:53:42 Voltage Offset Correction: v_off_ini = 159.969 uV, v_off_fin = 170.070 uV 15:53:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 313.424 uVs 15:53:42 Integrated Voltage Measurement... 15:53:51 Voltage Offset Correction: v_off_ini = 159.338 uV, v_off_fin = 137.344 uV 15:53:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -311.815 uVs 15:53:51 Integrated Voltage Measurement... 15:54:00 Voltage Offset Correction: v_off_ini = 138.084 uV, v_off_fin = 151.238 uV 15:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 309.639 uVs 15:54:00 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = 136.879 uV, v_off_fin = 128.074 uV 15:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.397 uVs 15:54:09 Integrated Voltage Measurement... 15:54:18 Voltage Offset Correction: v_off_ini = 149.894 uV, v_off_fin = 167.574 uV 15:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 308.220 uVs 15:54:22 I1Y Average and RMS of Measurements VT = -307.388 +- 2.694 uVs I1Y = -61.478 +- 0.539 uTm 15:54:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:30 Integrated Voltage Measurement... 15:54:39 Voltage Offset Correction: v_off_ini = 164.873 uV, v_off_fin = 142.365 uV 15:54:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -121.292 uVs 15:54:39 Integrated Voltage Measurement... 15:54:48 Voltage Offset Correction: v_off_ini = 158.284 uV, v_off_fin = 164.961 uV 15:54:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.186 uVs 15:54:48 Integrated Voltage Measurement... 15:54:57 Voltage Offset Correction: v_off_ini = 144.371 uV, v_off_fin = 146.620 uV 15:54:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.144 uVs 15:54:57 Integrated Voltage Measurement... 15:55:06 Voltage Offset Correction: v_off_ini = 142.430 uV, v_off_fin = 155.757 uV 15:55:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.932 uVs 15:55:06 Integrated Voltage Measurement... 15:55:15 Voltage Offset Correction: v_off_ini = 144.156 uV, v_off_fin = 148.007 uV 15:55:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.865 uVs 15:55:15 Integrated Voltage Measurement... 15:55:24 Voltage Offset Correction: v_off_ini = 167.852 uV, v_off_fin = 161.959 uV 15:55:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.878 uVs 15:55:27 I2X Average and RMS of Measurements VT = -112.383 +- 6.246 uVs I2X = 10.339 +- 0.575 uTm^2 15:55:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:34 Integrated Voltage Measurement... 15:55:43 Voltage Offset Correction: v_off_ini = 150.872 uV, v_off_fin = 150.251 uV 15:55:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -527.103 uVs 15:55:44 Integrated Voltage Measurement... 15:55:53 Voltage Offset Correction: v_off_ini = 143.390 uV, v_off_fin = 150.470 uV 15:55:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 512.982 uVs 15:55:53 Integrated Voltage Measurement... 15:56:02 Voltage Offset Correction: v_off_ini = 147.685 uV, v_off_fin = 146.107 uV 15:56:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -520.274 uVs 15:56:02 Integrated Voltage Measurement... 15:56:11 Voltage Offset Correction: v_off_ini = 128.819 uV, v_off_fin = 136.592 uV 15:56:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 525.836 uVs 15:56:11 Integrated Voltage Measurement... 15:56:20 Voltage Offset Correction: v_off_ini = 140.496 uV, v_off_fin = 130.846 uV 15:56:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.031 uVs 15:56:20 Integrated Voltage Measurement... 15:56:29 Voltage Offset Correction: v_off_ini = 135.791 uV, v_off_fin = 134.797 uV 15:56:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 529.481 uVs 15:56:31 I2Y Average and RMS of Measurements VT = -521.451 +- 1.238 uVs I2Y = -47.974 +- 0.114 uTm^2 15:56:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:46 Integrated Voltage Measurement... 15:56:55 Voltage Offset Correction: v_off_ini = 129.563 uV, v_off_fin = 124.281 uV 15:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.247 uVs 15:56:55 Integrated Voltage Measurement... 15:57:04 Voltage Offset Correction: v_off_ini = 128.712 uV, v_off_fin = 126.802 uV 15:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.631 uVs 15:57:04 Integrated Voltage Measurement... 15:57:13 Voltage Offset Correction: v_off_ini = 129.785 uV, v_off_fin = 110.523 uV 15:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.084 uVs 15:57:13 Integrated Voltage Measurement... 15:57:22 Voltage Offset Correction: v_off_ini = 119.767 uV, v_off_fin = 128.514 uV 15:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.928 uVs 15:57:22 Integrated Voltage Measurement... 15:57:31 Voltage Offset Correction: v_off_ini = 128.851 uV, v_off_fin = 118.650 uV 15:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.156 uVs 15:57:31 Integrated Voltage Measurement... 15:57:40 Voltage Offset Correction: v_off_ini = 123.232 uV, v_off_fin = 131.284 uV 15:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.744 uVs 15:57:44 I1X Average and RMS of Measurements VT = -118.132 +- 6.437 uVs I1X = 23.626 +- 1.287 uTm 15:57:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:51 Integrated Voltage Measurement... 15:58:00 Voltage Offset Correction: v_off_ini = 101.380 uV, v_off_fin = 99.006 uV 15:58:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.350 uVs 15:58:00 Integrated Voltage Measurement... 15:58:09 Voltage Offset Correction: v_off_ini = 116.347 uV, v_off_fin = 125.493 uV 15:58:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.189 uVs 15:58:09 Integrated Voltage Measurement... 15:58:18 Voltage Offset Correction: v_off_ini = 122.539 uV, v_off_fin = 116.138 uV 15:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.078 uVs 15:58:18 Integrated Voltage Measurement... 15:58:27 Voltage Offset Correction: v_off_ini = 121.937 uV, v_off_fin = 135.027 uV 15:58:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 304.404 uVs 15:58:27 Integrated Voltage Measurement... 15:58:36 Voltage Offset Correction: v_off_ini = 116.248 uV, v_off_fin = 105.761 uV 15:58:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -290.121 uVs 15:58:36 Integrated Voltage Measurement... 15:58:45 Voltage Offset Correction: v_off_ini = 118.324 uV, v_off_fin = 135.911 uV 15:58:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.232 uVs 15:58:49 I1Y Average and RMS of Measurements VT = -288.229 +- 7.094 uVs I1Y = -57.646 +- 1.419 uTm 15:58:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:57 Integrated Voltage Measurement... 15:59:06 Voltage Offset Correction: v_off_ini = 98.751 uV, v_off_fin = 101.665 uV 15:59:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -122.225 uVs 15:59:06 Integrated Voltage Measurement... 15:59:15 Voltage Offset Correction: v_off_ini = 112.851 uV, v_off_fin = 117.203 uV 15:59:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.965 uVs 15:59:15 Integrated Voltage Measurement... 15:59:24 Voltage Offset Correction: v_off_ini = 110.510 uV, v_off_fin = 110.486 uV 15:59:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.186 uVs 15:59:24 Integrated Voltage Measurement... 15:59:33 Voltage Offset Correction: v_off_ini = 121.879 uV, v_off_fin = 121.492 uV 15:59:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.027 uVs 15:59:33 Integrated Voltage Measurement... 15:59:42 Voltage Offset Correction: v_off_ini = 125.498 uV, v_off_fin = 122.332 uV 15:59:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.210 uVs 15:59:42 Integrated Voltage Measurement... 15:59:51 Voltage Offset Correction: v_off_ini = 129.473 uV, v_off_fin = 127.310 uV 15:59:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.634 uVs 15:59:54 I2X Average and RMS of Measurements VT = -117.541 +- 3.568 uVs I2X = 10.813 +- 0.328 uTm^2 15:59:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:02 Integrated Voltage Measurement... 16:00:11 Voltage Offset Correction: v_off_ini = 118.672 uV, v_off_fin = 117.325 uV 16:00:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -483.534 uVs 16:00:11 Integrated Voltage Measurement... 16:00:20 Voltage Offset Correction: v_off_ini = 135.115 uV, v_off_fin = 120.574 uV 16:00:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 514.123 uVs 16:00:20 Integrated Voltage Measurement... 16:00:29 Voltage Offset Correction: v_off_ini = 127.796 uV, v_off_fin = 108.766 uV 16:00:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -474.601 uVs 16:00:29 Integrated Voltage Measurement... 16:00:38 Voltage Offset Correction: v_off_ini = 118.316 uV, v_off_fin = 113.022 uV 16:00:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.334 uVs 16:00:38 Integrated Voltage Measurement... 16:00:47 Voltage Offset Correction: v_off_ini = 108.095 uV, v_off_fin = 113.664 uV 16:00:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -488.012 uVs 16:00:47 Integrated Voltage Measurement... 16:00:56 Voltage Offset Correction: v_off_ini = 101.624 uV, v_off_fin = 104.488 uV 16:00:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 476.867 uVs 16:00:58 I2Y Average and RMS of Measurements VT = -487.245 +- 8.230 uVs I2Y = -44.827 +- 0.758 uTm^2 16:01:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:13 Integrated Voltage Measurement... 16:01:22 Voltage Offset Correction: v_off_ini = 122.992 uV, v_off_fin = 98.432 uV 16:01:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.513 uVs 16:01:22 Integrated Voltage Measurement... 16:01:31 Voltage Offset Correction: v_off_ini = 104.102 uV, v_off_fin = 104.928 uV 16:01:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.284 uVs 16:01:31 Integrated Voltage Measurement... 16:01:40 Voltage Offset Correction: v_off_ini = 120.208 uV, v_off_fin = 118.996 uV 16:01:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.317 uVs 16:01:40 Integrated Voltage Measurement... 16:01:49 Voltage Offset Correction: v_off_ini = 113.153 uV, v_off_fin = 120.927 uV 16:01:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.946 uVs 16:01:49 Integrated Voltage Measurement... 16:01:58 Voltage Offset Correction: v_off_ini = 114.128 uV, v_off_fin = 120.042 uV 16:01:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.783 uVs 16:01:58 Integrated Voltage Measurement... 16:02:07 Voltage Offset Correction: v_off_ini = 132.344 uV, v_off_fin = 129.761 uV 16:02:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 146.994 uVs 16:02:12 I1X Average and RMS of Measurements VT = -141.973 +- 6.537 uVs I1X = 28.396 +- 1.309 uTm 16:02:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:18 Integrated Voltage Measurement... 16:02:27 Voltage Offset Correction: v_off_ini = 135.741 uV, v_off_fin = 124.171 uV 16:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.877 uVs 16:02:27 Integrated Voltage Measurement... 16:02:36 Voltage Offset Correction: v_off_ini = 126.686 uV, v_off_fin = 137.975 uV 16:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.622 uVs 16:02:36 Integrated Voltage Measurement... 16:02:45 Voltage Offset Correction: v_off_ini = 141.828 uV, v_off_fin = 110.258 uV 16:02:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.941 uVs 16:02:46 Integrated Voltage Measurement... 16:02:55 Voltage Offset Correction: v_off_ini = 132.174 uV, v_off_fin = 146.963 uV 16:02:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.846 uVs 16:02:55 Integrated Voltage Measurement... 16:03:04 Voltage Offset Correction: v_off_ini = 132.607 uV, v_off_fin = 120.314 uV 16:03:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.590 uVs 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = 131.110 uV, v_off_fin = 139.967 uV 16:03:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.542 uVs 16:03:17 I1Y Average and RMS of Measurements VT = -270.570 +- 3.692 uVs I1Y = -54.114 +- 0.738 uTm 16:03:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:25 Integrated Voltage Measurement... 16:03:34 Voltage Offset Correction: v_off_ini = 128.047 uV, v_off_fin = 123.736 uV 16:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.767 uVs 16:03:34 Integrated Voltage Measurement... 16:03:43 Voltage Offset Correction: v_off_ini = 128.950 uV, v_off_fin = 143.119 uV 16:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.172 uVs 16:03:43 Integrated Voltage Measurement... 16:03:52 Voltage Offset Correction: v_off_ini = 133.293 uV, v_off_fin = 130.753 uV 16:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.931 uVs 16:03:52 Integrated Voltage Measurement... 16:04:01 Voltage Offset Correction: v_off_ini = 136.641 uV, v_off_fin = 144.310 uV 16:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.951 uVs 16:04:01 Integrated Voltage Measurement... 16:04:10 Voltage Offset Correction: v_off_ini = 133.756 uV, v_off_fin = 125.174 uV 16:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.536 uVs 16:04:10 Integrated Voltage Measurement... 16:04:19 Voltage Offset Correction: v_off_ini = 126.448 uV, v_off_fin = 138.299 uV 16:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.707 uVs 16:04:22 I2X Average and RMS of Measurements VT = -127.344 +- 8.301 uVs I2X = 11.716 +- 0.764 uTm^2 16:04:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:29 Integrated Voltage Measurement... 16:04:38 Voltage Offset Correction: v_off_ini = 123.856 uV, v_off_fin = 121.517 uV 16:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.559 uVs 16:04:38 Integrated Voltage Measurement... 16:04:47 Voltage Offset Correction: v_off_ini = 146.045 uV, v_off_fin = 142.417 uV 16:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.269 uVs 16:04:47 Integrated Voltage Measurement... 16:04:56 Voltage Offset Correction: v_off_ini = 143.364 uV, v_off_fin = 144.280 uV 16:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.235 uVs 16:04:56 Integrated Voltage Measurement... 16:05:05 Voltage Offset Correction: v_off_ini = 138.346 uV, v_off_fin = 127.247 uV 16:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.930 uVs 16:05:05 Integrated Voltage Measurement... 16:05:14 Voltage Offset Correction: v_off_ini = 129.805 uV, v_off_fin = 137.008 uV 16:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.126 uVs 16:05:15 Integrated Voltage Measurement... 16:05:23 Voltage Offset Correction: v_off_ini = 120.613 uV, v_off_fin = 118.120 uV 16:05:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.502 uVs 16:05:26 I2Y Average and RMS of Measurements VT = -456.937 +- 5.631 uVs I2Y = -42.038 +- 0.518 uTm^2 16:05:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = 120.816 uV, v_off_fin = 111.662 uV 16:05:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -157.634 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 125.973 uV, v_off_fin = 125.681 uV 16:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 122.907 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = 126.222 uV, v_off_fin = 96.901 uV 16:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.672 uVs 16:06:08 Integrated Voltage Measurement... 16:06:17 Voltage Offset Correction: v_off_ini = 106.780 uV, v_off_fin = 121.011 uV 16:06:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.863 uVs 16:06:17 Integrated Voltage Measurement... 16:06:26 Voltage Offset Correction: v_off_ini = 133.191 uV, v_off_fin = 109.701 uV 16:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.535 uVs 16:06:26 Integrated Voltage Measurement... 16:06:35 Voltage Offset Correction: v_off_ini = 120.432 uV, v_off_fin = 108.289 uV 16:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.905 uVs 16:06:39 I1X Average and RMS of Measurements VT = -137.419 +- 2.269 uVs I1X = 27.486 +- 0.456 uTm 16:06:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = 93.680 uV, v_off_fin = 102.576 uV 16:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.750 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = 98.515 uV, v_off_fin = 118.157 uV 16:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.940 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 100.165 uV, v_off_fin = 92.370 uV 16:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.705 uVs 16:07:13 Integrated Voltage Measurement... 16:07:22 Voltage Offset Correction: v_off_ini = 110.940 uV, v_off_fin = 105.428 uV 16:07:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.772 uVs 16:07:22 Integrated Voltage Measurement... 16:07:31 Voltage Offset Correction: v_off_ini = 110.507 uV, v_off_fin = 102.303 uV 16:07:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.796 uVs 16:07:31 Integrated Voltage Measurement... 16:07:40 Voltage Offset Correction: v_off_ini = 96.130 uV, v_off_fin = 114.327 uV 16:07:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.245 uVs 16:07:44 I1Y Average and RMS of Measurements VT = -246.868 +- 2.495 uVs I1Y = -49.374 +- 0.499 uTm 16:07:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:52 Integrated Voltage Measurement... 16:08:01 Voltage Offset Correction: v_off_ini = 82.631 uV, v_off_fin = 88.537 uV 16:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.940 uVs 16:08:01 Integrated Voltage Measurement... 16:08:10 Voltage Offset Correction: v_off_ini = 110.296 uV, v_off_fin = 105.861 uV 16:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.240 uVs 16:08:10 Integrated Voltage Measurement... 16:08:19 Voltage Offset Correction: v_off_ini = 96.365 uV, v_off_fin = 94.755 uV 16:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.443 uVs 16:08:19 Integrated Voltage Measurement... 16:08:28 Voltage Offset Correction: v_off_ini = 100.483 uV, v_off_fin = 113.098 uV 16:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.491 uVs 16:08:28 Integrated Voltage Measurement... 16:08:37 Voltage Offset Correction: v_off_ini = 107.373 uV, v_off_fin = 99.026 uV 16:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.199 uVs 16:08:37 Integrated Voltage Measurement... 16:08:46 Voltage Offset Correction: v_off_ini = 117.589 uV, v_off_fin = 111.175 uV 16:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.724 uVs 16:08:49 I2X Average and RMS of Measurements VT = -133.673 +- 7.839 uVs I2X = 12.298 +- 0.721 uTm^2 16:08:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:56 Integrated Voltage Measurement... 16:09:05 Voltage Offset Correction: v_off_ini = 99.779 uV, v_off_fin = 94.768 uV 16:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.867 uVs 16:09:05 Integrated Voltage Measurement... 16:09:14 Voltage Offset Correction: v_off_ini = 102.888 uV, v_off_fin = 109.359 uV 16:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 436.150 uVs 16:09:14 Integrated Voltage Measurement... 16:09:23 Voltage Offset Correction: v_off_ini = 108.225 uV, v_off_fin = 94.848 uV 16:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -444.179 uVs 16:09:23 Integrated Voltage Measurement... 16:09:32 Voltage Offset Correction: v_off_ini = 85.868 uV, v_off_fin = 89.546 uV 16:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 437.320 uVs 16:09:33 Integrated Voltage Measurement... 16:09:41 Voltage Offset Correction: v_off_ini = 104.553 uV, v_off_fin = 92.972 uV 16:09:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.767 uVs 16:09:42 Integrated Voltage Measurement... 16:09:51 Voltage Offset Correction: v_off_ini = 102.088 uV, v_off_fin = 115.016 uV 16:09:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 427.126 uVs 16:09:53 I2Y Average and RMS of Measurements VT = -433.401 +- 5.382 uVs I2Y = -39.873 +- 0.495 uTm^2 16:10:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:08 Integrated Voltage Measurement... 16:10:17 Voltage Offset Correction: v_off_ini = 110.045 uV, v_off_fin = 107.175 uV 16:10:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -160.560 uVs 16:10:17 Integrated Voltage Measurement... 16:10:26 Voltage Offset Correction: v_off_ini = 121.907 uV, v_off_fin = 122.226 uV 16:10:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.178 uVs 16:10:26 Integrated Voltage Measurement... 16:10:35 Voltage Offset Correction: v_off_ini = 125.383 uV, v_off_fin = 115.020 uV 16:10:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.748 uVs 16:10:35 Integrated Voltage Measurement... 16:10:44 Voltage Offset Correction: v_off_ini = 119.214 uV, v_off_fin = 122.009 uV 16:10:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.014 uVs 16:10:44 Integrated Voltage Measurement... 16:10:53 Voltage Offset Correction: v_off_ini = 104.223 uV, v_off_fin = 102.070 uV 16:10:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.009 uVs 16:10:53 Integrated Voltage Measurement... 16:11:02 Voltage Offset Correction: v_off_ini = 92.839 uV, v_off_fin = 105.535 uV 16:11:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.030 uVs 16:11:06 I1X Average and RMS of Measurements VT = -161.756 +- 2.931 uVs I1X = 32.352 +- 0.586 uTm 16:11:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:13 Integrated Voltage Measurement... 16:11:22 Voltage Offset Correction: v_off_ini = 107.226 uV, v_off_fin = 98.714 uV 16:11:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.610 uVs 16:11:22 Integrated Voltage Measurement... 16:11:31 Voltage Offset Correction: v_off_ini = 118.975 uV, v_off_fin = 127.310 uV 16:11:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.348 uVs 16:11:31 Integrated Voltage Measurement... 16:11:40 Voltage Offset Correction: v_off_ini = 110.358 uV, v_off_fin = 87.820 uV 16:11:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.280 uVs 16:11:40 Integrated Voltage Measurement... 16:11:49 Voltage Offset Correction: v_off_ini = 100.068 uV, v_off_fin = 121.661 uV 16:11:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 249.428 uVs 16:11:49 Integrated Voltage Measurement... 16:11:58 Voltage Offset Correction: v_off_ini = 101.078 uV, v_off_fin = 96.132 uV 16:11:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.748 uVs 16:11:58 Integrated Voltage Measurement... 16:12:07 Voltage Offset Correction: v_off_ini = 120.977 uV, v_off_fin = 120.195 uV 16:12:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.764 uVs 16:12:11 I1Y Average and RMS of Measurements VT = -240.863 +- 6.481 uVs I1Y = -48.171 +- 1.295 uTm 16:12:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:19 Integrated Voltage Measurement... 16:12:28 Voltage Offset Correction: v_off_ini = 113.630 uV, v_off_fin = 109.770 uV 16:12:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -142.683 uVs 16:12:28 Integrated Voltage Measurement... 16:12:37 Voltage Offset Correction: v_off_ini = 112.500 uV, v_off_fin = 116.350 uV 16:12:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.990 uVs 16:12:37 Integrated Voltage Measurement... 16:12:46 Voltage Offset Correction: v_off_ini = 127.273 uV, v_off_fin = 114.307 uV 16:12:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.275 uVs 16:12:46 Integrated Voltage Measurement... 16:12:55 Voltage Offset Correction: v_off_ini = 113.491 uV, v_off_fin = 136.657 uV 16:12:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.423 uVs 16:12:55 Integrated Voltage Measurement... 16:13:04 Voltage Offset Correction: v_off_ini = 118.613 uV, v_off_fin = 102.557 uV 16:13:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.489 uVs 16:13:04 Integrated Voltage Measurement... 16:13:13 Voltage Offset Correction: v_off_ini = 113.848 uV, v_off_fin = 126.097 uV 16:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.467 uVs 16:13:15 I2X Average and RMS of Measurements VT = -140.554 +- 6.900 uVs I2X = 12.931 +- 0.635 uTm^2 16:13:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:23 Integrated Voltage Measurement... 16:13:32 Voltage Offset Correction: v_off_ini = 110.831 uV, v_off_fin = 106.575 uV 16:13:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -415.149 uVs 16:13:32 Integrated Voltage Measurement... 16:13:41 Voltage Offset Correction: v_off_ini = 117.587 uV, v_off_fin = 104.909 uV 16:13:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.324 uVs 16:13:41 Integrated Voltage Measurement... 16:13:50 Voltage Offset Correction: v_off_ini = 99.294 uV, v_off_fin = 104.076 uV 16:13:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.141 uVs 16:13:50 Integrated Voltage Measurement... 16:13:59 Voltage Offset Correction: v_off_ini = 91.085 uV, v_off_fin = 95.382 uV 16:13:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.454 uVs 16:13:59 Integrated Voltage Measurement... 16:14:08 Voltage Offset Correction: v_off_ini = 105.468 uV, v_off_fin = 104.078 uV 16:14:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -405.508 uVs 16:14:08 Integrated Voltage Measurement... 16:14:17 Voltage Offset Correction: v_off_ini = 99.101 uV, v_off_fin = 109.314 uV 16:14:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.101 uVs 16:14:20 I2Y Average and RMS of Measurements VT = -412.113 +- 3.121 uVs I2Y = -37.915 +- 0.286 uTm^2 16:14:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:35 Integrated Voltage Measurement... 16:14:44 Voltage Offset Correction: v_off_ini = 105.075 uV, v_off_fin = 111.467 uV 16:14:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.757 uVs 16:14:44 Integrated Voltage Measurement... 16:14:53 Voltage Offset Correction: v_off_ini = 116.593 uV, v_off_fin = 96.856 uV 16:14:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.694 uVs 16:14:53 Integrated Voltage Measurement... 16:15:02 Voltage Offset Correction: v_off_ini = 101.054 uV, v_off_fin = 97.059 uV 16:15:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.658 uVs 16:15:02 Integrated Voltage Measurement... 16:15:11 Voltage Offset Correction: v_off_ini = 86.260 uV, v_off_fin = 88.205 uV 16:15:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 152.249 uVs 16:15:11 Integrated Voltage Measurement... 16:15:20 Voltage Offset Correction: v_off_ini = 84.616 uV, v_off_fin = 104.578 uV 16:15:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.916 uVs 16:15:20 Integrated Voltage Measurement... 16:15:29 Voltage Offset Correction: v_off_ini = 111.031 uV, v_off_fin = 116.194 uV 16:15:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.598 uVs 16:15:33 I1X Average and RMS of Measurements VT = -141.979 +- 10.093 uVs I1X = 28.398 +- 2.020 uTm 16:15:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:40 Integrated Voltage Measurement... 16:15:49 Voltage Offset Correction: v_off_ini = 96.414 uV, v_off_fin = 89.505 uV 16:15:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -220.436 uVs 16:15:49 Integrated Voltage Measurement... 16:15:58 Voltage Offset Correction: v_off_ini = 108.209 uV, v_off_fin = 116.325 uV 16:15:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.001 uVs 16:15:58 Integrated Voltage Measurement... 16:16:07 Voltage Offset Correction: v_off_ini = 114.192 uV, v_off_fin = 100.234 uV 16:16:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -247.754 uVs 16:16:07 Integrated Voltage Measurement... 16:16:16 Voltage Offset Correction: v_off_ini = 107.314 uV, v_off_fin = 129.195 uV 16:16:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.190 uVs 16:16:16 Integrated Voltage Measurement... 16:16:25 Voltage Offset Correction: v_off_ini = 96.723 uV, v_off_fin = 91.772 uV 16:16:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.844 uVs 16:16:25 Integrated Voltage Measurement... 16:16:34 Voltage Offset Correction: v_off_ini = 118.544 uV, v_off_fin = 121.094 uV 16:16:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.927 uVs 16:16:38 I1Y Average and RMS of Measurements VT = -228.025 +- 9.204 uVs I1Y = -45.603 +- 1.839 uTm 16:16:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:46 Integrated Voltage Measurement... 16:16:55 Voltage Offset Correction: v_off_ini = 113.845 uV, v_off_fin = 112.995 uV 16:16:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -149.183 uVs 16:16:55 Integrated Voltage Measurement... 16:17:04 Voltage Offset Correction: v_off_ini = 114.012 uV, v_off_fin = 126.792 uV 16:17:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 168.868 uVs 16:17:04 Integrated Voltage Measurement... 16:17:13 Voltage Offset Correction: v_off_ini = 116.118 uV, v_off_fin = 113.095 uV 16:17:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -132.401 uVs 16:17:13 Integrated Voltage Measurement... 16:17:22 Voltage Offset Correction: v_off_ini = 118.455 uV, v_off_fin = 117.399 uV 16:17:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 139.747 uVs 16:17:22 Integrated Voltage Measurement... 16:17:31 Voltage Offset Correction: v_off_ini = 115.732 uV, v_off_fin = 120.107 uV 16:17:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.713 uVs 16:17:31 Integrated Voltage Measurement... 16:17:40 Voltage Offset Correction: v_off_ini = 139.527 uV, v_off_fin = 139.889 uV 16:17:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.104 uVs 16:17:42 I2X Average and RMS of Measurements VT = -148.336 +- 9.436 uVs I2X = 13.647 +- 0.868 uTm^2 16:17:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:50 Integrated Voltage Measurement... 16:17:59 Voltage Offset Correction: v_off_ini = 131.595 uV, v_off_fin = 119.876 uV 16:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -412.567 uVs 16:17:59 Integrated Voltage Measurement... 16:18:08 Voltage Offset Correction: v_off_ini = 118.879 uV, v_off_fin = 128.986 uV 16:18:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 402.005 uVs 16:18:08 Integrated Voltage Measurement... 16:18:17 Voltage Offset Correction: v_off_ini = 118.468 uV, v_off_fin = 130.138 uV 16:18:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.701 uVs 16:18:17 Integrated Voltage Measurement... 16:18:26 Voltage Offset Correction: v_off_ini = 123.702 uV, v_off_fin = 126.762 uV 16:18:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.126 uVs 16:18:26 Integrated Voltage Measurement... 16:18:35 Voltage Offset Correction: v_off_ini = 133.791 uV, v_off_fin = 130.523 uV 16:18:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.111 uVs 16:18:35 Integrated Voltage Measurement... 16:18:44 Voltage Offset Correction: v_off_ini = 134.208 uV, v_off_fin = 137.184 uV 16:18:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 406.611 uVs 16:18:47 I2Y Average and RMS of Measurements VT = -408.853 +- 4.407 uVs I2Y = -37.615 +- 0.405 uTm^2 16:18:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:02 Integrated Voltage Measurement... 16:19:11 Voltage Offset Correction: v_off_ini = 159.727 uV, v_off_fin = 137.014 uV 16:19:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -180.689 uVs 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = 136.458 uV, v_off_fin = 131.897 uV 16:19:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.928 uVs 16:19:20 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = 148.126 uV, v_off_fin = 151.401 uV 16:19:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.850 uVs 16:19:29 Integrated Voltage Measurement... 16:19:38 Voltage Offset Correction: v_off_ini = 149.343 uV, v_off_fin = 143.632 uV 16:19:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.057 uVs 16:19:38 Integrated Voltage Measurement... 16:19:47 Voltage Offset Correction: v_off_ini = 142.479 uV, v_off_fin = 151.095 uV 16:19:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.292 uVs 16:19:47 Integrated Voltage Measurement... 16:19:56 Voltage Offset Correction: v_off_ini = 146.666 uV, v_off_fin = 157.998 uV 16:19:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.404 uVs 16:20:00 I1X Average and RMS of Measurements VT = -166.370 +- 13.223 uVs I1X = 33.276 +- 2.647 uTm 16:20:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:07 Integrated Voltage Measurement... 16:20:16 Voltage Offset Correction: v_off_ini = 145.102 uV, v_off_fin = 152.928 uV 16:20:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -234.361 uVs 16:20:16 Integrated Voltage Measurement... 16:20:25 Voltage Offset Correction: v_off_ini = 166.976 uV, v_off_fin = 170.939 uV 16:20:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.709 uVs 16:20:25 Integrated Voltage Measurement... 16:20:34 Voltage Offset Correction: v_off_ini = 158.114 uV, v_off_fin = 149.389 uV 16:20:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.692 uVs 16:20:34 Integrated Voltage Measurement... 16:20:43 Voltage Offset Correction: v_off_ini = 152.440 uV, v_off_fin = 159.984 uV 16:20:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.608 uVs 16:20:43 Integrated Voltage Measurement... 16:20:52 Voltage Offset Correction: v_off_ini = 160.136 uV, v_off_fin = 147.469 uV 16:20:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.113 uVs 16:20:52 Integrated Voltage Measurement... 16:21:01 Voltage Offset Correction: v_off_ini = 150.797 uV, v_off_fin = 163.420 uV 16:21:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.153 uVs 16:21:05 I1Y Average and RMS of Measurements VT = -225.106 +- 1.384 uVs I1Y = -45.019 +- 0.278 uTm 16:21:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:13 Integrated Voltage Measurement... 16:21:22 Voltage Offset Correction: v_off_ini = 156.745 uV, v_off_fin = 158.921 uV 16:21:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -162.271 uVs 16:21:22 Integrated Voltage Measurement... 16:21:31 Voltage Offset Correction: v_off_ini = 168.069 uV, v_off_fin = 164.140 uV 16:21:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.230 uVs 16:21:31 Integrated Voltage Measurement... 16:21:40 Voltage Offset Correction: v_off_ini = 153.636 uV, v_off_fin = 148.596 uV 16:21:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.864 uVs 16:21:40 Integrated Voltage Measurement... 16:21:49 Voltage Offset Correction: v_off_ini = 158.629 uV, v_off_fin = 163.231 uV 16:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.749 uVs 16:21:49 Integrated Voltage Measurement... 16:21:58 Voltage Offset Correction: v_off_ini = 164.519 uV, v_off_fin = 141.472 uV 16:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.497 uVs 16:21:58 Integrated Voltage Measurement... 16:22:07 Voltage Offset Correction: v_off_ini = 133.764 uV, v_off_fin = 159.673 uV 16:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.652 uVs 16:22:09 I2X Average and RMS of Measurements VT = -150.044 +- 5.164 uVs I2X = 13.804 +- 0.475 uTm^2 16:22:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:17 Integrated Voltage Measurement... 16:22:26 Voltage Offset Correction: v_off_ini = 139.023 uV, v_off_fin = 145.282 uV 16:22:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -385.068 uVs 16:22:26 Integrated Voltage Measurement... 16:22:35 Voltage Offset Correction: v_off_ini = 143.922 uV, v_off_fin = 150.119 uV 16:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 379.643 uVs 16:22:35 Integrated Voltage Measurement... 16:22:44 Voltage Offset Correction: v_off_ini = 131.403 uV, v_off_fin = 148.130 uV 16:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.013 uVs 16:22:44 Integrated Voltage Measurement... 16:22:53 Voltage Offset Correction: v_off_ini = 135.288 uV, v_off_fin = 140.122 uV 16:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 392.898 uVs 16:22:53 Integrated Voltage Measurement... 16:23:02 Voltage Offset Correction: v_off_ini = 144.991 uV, v_off_fin = 137.668 uV 16:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.443 uVs 16:23:02 Integrated Voltage Measurement... 16:23:11 Voltage Offset Correction: v_off_ini = 132.862 uV, v_off_fin = 148.951 uV 16:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.225 uVs 16:23:14 I2Y Average and RMS of Measurements VT = -387.382 +- 5.375 uVs I2Y = -35.639 +- 0.495 uTm^2 16:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:29 Integrated Voltage Measurement... 16:23:38 Voltage Offset Correction: v_off_ini = 157.553 uV, v_off_fin = 165.638 uV 16:23:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -148.369 uVs 16:23:38 Integrated Voltage Measurement... 16:23:47 Voltage Offset Correction: v_off_ini = 172.385 uV, v_off_fin = 178.937 uV 16:23:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 157.409 uVs 16:23:47 Integrated Voltage Measurement... 16:23:56 Voltage Offset Correction: v_off_ini = 174.390 uV, v_off_fin = 156.077 uV 16:23:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -166.462 uVs 16:23:56 Integrated Voltage Measurement... 16:24:05 Voltage Offset Correction: v_off_ini = 157.139 uV, v_off_fin = 163.928 uV 16:24:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 149.045 uVs 16:24:05 Integrated Voltage Measurement... 16:24:14 Voltage Offset Correction: v_off_ini = 157.122 uV, v_off_fin = 149.051 uV 16:24:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.169 uVs 16:24:14 Integrated Voltage Measurement... 16:24:23 Voltage Offset Correction: v_off_ini = 155.184 uV, v_off_fin = 160.213 uV 16:24:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.244 uVs 16:24:27 I1X Average and RMS of Measurements VT = -156.450 +- 2.548 uVs I1X = 31.294 +- 0.509 uTm 16:24:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:34 Integrated Voltage Measurement... 16:24:43 Voltage Offset Correction: v_off_ini = 146.264 uV, v_off_fin = 149.211 uV 16:24:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.032 uVs 16:24:43 Integrated Voltage Measurement... 16:24:52 Voltage Offset Correction: v_off_ini = 139.038 uV, v_off_fin = 154.684 uV 16:24:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.600 uVs 16:24:52 Integrated Voltage Measurement... 16:25:01 Voltage Offset Correction: v_off_ini = 143.471 uV, v_off_fin = 144.855 uV 16:25:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.847 uVs 16:25:01 Integrated Voltage Measurement... 16:25:10 Voltage Offset Correction: v_off_ini = 157.891 uV, v_off_fin = 156.026 uV 16:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.224 uVs 16:25:10 Integrated Voltage Measurement... 16:25:19 Voltage Offset Correction: v_off_ini = 146.496 uV, v_off_fin = 145.045 uV 16:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.719 uVs 16:25:19 Integrated Voltage Measurement... 16:25:28 Voltage Offset Correction: v_off_ini = 147.915 uV, v_off_fin = 144.593 uV 16:25:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.072 uVs 16:25:32 I1Y Average and RMS of Measurements VT = -213.749 +- 4.645 uVs I1Y = -42.749 +- 0.929 uTm 16:25:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:40 Integrated Voltage Measurement... 16:25:49 Voltage Offset Correction: v_off_ini = 125.091 uV, v_off_fin = 133.714 uV 16:25:49 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -178.156 uVs 16:25:49 Integrated Voltage Measurement... 16:25:58 Voltage Offset Correction: v_off_ini = 150.000 uV, v_off_fin = 164.468 uV 16:25:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.725 uVs 16:25:58 Integrated Voltage Measurement... 16:26:07 Voltage Offset Correction: v_off_ini = 156.074 uV, v_off_fin = 144.801 uV 16:26:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.427 uVs 16:26:07 Integrated Voltage Measurement... 16:26:16 Voltage Offset Correction: v_off_ini = 150.231 uV, v_off_fin = 164.278 uV 16:26:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.185 uVs 16:26:16 Integrated Voltage Measurement... 16:26:25 Voltage Offset Correction: v_off_ini = 159.527 uV, v_off_fin = 141.851 uV 16:26:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -171.062 uVs 16:26:25 Integrated Voltage Measurement... 16:26:34 Voltage Offset Correction: v_off_ini = 146.955 uV, v_off_fin = 164.082 uV 16:26:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.613 uVs 16:26:36 I2X Average and RMS of Measurements VT = -165.861 +- 4.546 uVs I2X = 15.259 +- 0.418 uTm^2 16:26:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:44 Integrated Voltage Measurement... 16:26:53 Voltage Offset Correction: v_off_ini = 143.559 uV, v_off_fin = 145.980 uV 16:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.652 uVs 16:26:53 Integrated Voltage Measurement... 16:27:02 Voltage Offset Correction: v_off_ini = 150.196 uV, v_off_fin = 149.326 uV 16:27:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.575 uVs 16:27:02 Integrated Voltage Measurement... 16:27:11 Voltage Offset Correction: v_off_ini = 136.483 uV, v_off_fin = 144.088 uV 16:27:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -360.304 uVs 16:27:11 Integrated Voltage Measurement... 16:27:20 Voltage Offset Correction: v_off_ini = 149.292 uV, v_off_fin = 153.299 uV 16:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.472 uVs 16:27:20 Integrated Voltage Measurement... 16:27:29 Voltage Offset Correction: v_off_ini = 160.543 uV, v_off_fin = 152.525 uV 16:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.753 uVs 16:27:29 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 142.336 uV, v_off_fin = 141.347 uV 16:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.081 uVs 16:27:40 I2Y Average and RMS of Measurements VT = -371.139 +- 5.501 uVs I2Y = -34.145 +- 0.506 uTm^2 16:27:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:55 Integrated Voltage Measurement... 16:28:04 Voltage Offset Correction: v_off_ini = 146.679 uV, v_off_fin = 153.175 uV 16:28:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -182.610 uVs 16:28:04 Integrated Voltage Measurement... 16:28:13 Voltage Offset Correction: v_off_ini = 152.176 uV, v_off_fin = 164.595 uV 16:28:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.689 uVs 16:28:13 Integrated Voltage Measurement... 16:28:22 Voltage Offset Correction: v_off_ini = 146.471 uV, v_off_fin = 141.818 uV 16:28:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.827 uVs 16:28:22 Integrated Voltage Measurement... 16:28:31 Voltage Offset Correction: v_off_ini = 154.486 uV, v_off_fin = 149.163 uV 16:28:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.251 uVs 16:28:31 Integrated Voltage Measurement... 16:28:40 Voltage Offset Correction: v_off_ini = 141.232 uV, v_off_fin = 133.202 uV 16:28:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -171.490 uVs 16:28:40 Integrated Voltage Measurement... 16:28:49 Voltage Offset Correction: v_off_ini = 132.663 uV, v_off_fin = 132.029 uV 16:28:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 162.314 uVs 16:28:53 I1X Average and RMS of Measurements VT = -167.863 +- 5.193 uVs I1X = 33.574 +- 1.038 uTm 16:28:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:00 Integrated Voltage Measurement... 16:29:09 Voltage Offset Correction: v_off_ini = 139.829 uV, v_off_fin = 137.357 uV 16:29:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.943 uVs 16:29:09 Integrated Voltage Measurement... 16:29:18 Voltage Offset Correction: v_off_ini = 152.530 uV, v_off_fin = 151.191 uV 16:29:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.865 uVs 16:29:18 Integrated Voltage Measurement... 16:29:27 Voltage Offset Correction: v_off_ini = 135.979 uV, v_off_fin = 141.931 uV 16:29:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.057 uVs 16:29:27 Integrated Voltage Measurement... 16:29:36 Voltage Offset Correction: v_off_ini = 131.836 uV, v_off_fin = 153.126 uV 16:29:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.757 uVs 16:29:36 Integrated Voltage Measurement... 16:29:45 Voltage Offset Correction: v_off_ini = 156.905 uV, v_off_fin = 142.587 uV 16:29:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.356 uVs 16:29:45 Integrated Voltage Measurement... 16:29:54 Voltage Offset Correction: v_off_ini = 151.332 uV, v_off_fin = 158.522 uV 16:29:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.829 uVs 16:29:58 I1Y Average and RMS of Measurements VT = -202.968 +- 3.992 uVs I1Y = -40.592 +- 0.799 uTm 16:30:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:06 Integrated Voltage Measurement... 16:30:15 Voltage Offset Correction: v_off_ini = 134.980 uV, v_off_fin = 128.354 uV 16:30:15 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -171.809 uVs 16:30:15 Integrated Voltage Measurement... 16:30:24 Voltage Offset Correction: v_off_ini = 128.001 uV, v_off_fin = 137.027 uV 16:30:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.429 uVs 16:30:24 Integrated Voltage Measurement... 16:30:33 Voltage Offset Correction: v_off_ini = 129.140 uV, v_off_fin = 136.099 uV 16:30:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.872 uVs 16:30:33 Integrated Voltage Measurement... 16:30:42 Voltage Offset Correction: v_off_ini = 151.910 uV, v_off_fin = 141.687 uV 16:30:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 155.814 uVs 16:30:42 Integrated Voltage Measurement... 16:30:51 Voltage Offset Correction: v_off_ini = 134.285 uV, v_off_fin = 137.154 uV 16:30:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -164.607 uVs 16:30:51 Integrated Voltage Measurement... 16:31:00 Voltage Offset Correction: v_off_ini = 135.528 uV, v_off_fin = 135.505 uV 16:31:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.079 uVs 16:31:03 I2X Average and RMS of Measurements VT = -159.435 +- 6.507 uVs I2X = 14.668 +- 0.598 uTm^2 16:31:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:10 Integrated Voltage Measurement... 16:31:19 Voltage Offset Correction: v_off_ini = 132.753 uV, v_off_fin = 136.442 uV 16:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.979 uVs 16:31:19 Integrated Voltage Measurement... 16:31:28 Voltage Offset Correction: v_off_ini = 127.081 uV, v_off_fin = 140.043 uV 16:31:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.800 uVs 16:31:28 Integrated Voltage Measurement... 16:31:37 Voltage Offset Correction: v_off_ini = 134.523 uV, v_off_fin = 137.650 uV 16:31:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.090 uVs 16:31:37 Integrated Voltage Measurement... 16:31:46 Voltage Offset Correction: v_off_ini = 137.592 uV, v_off_fin = 136.237 uV 16:31:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.032 uVs 16:31:46 Integrated Voltage Measurement... 16:31:55 Voltage Offset Correction: v_off_ini = 142.251 uV, v_off_fin = 124.831 uV 16:31:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.711 uVs 16:31:55 Integrated Voltage Measurement... 16:32:04 Voltage Offset Correction: v_off_ini = 127.428 uV, v_off_fin = 129.182 uV 16:32:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.060 uVs 16:32:07 I2Y Average and RMS of Measurements VT = -359.779 +- 4.000 uVs I2Y = -33.100 +- 0.368 uTm^2 16:32:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:22 Integrated Voltage Measurement... 16:32:31 Voltage Offset Correction: v_off_ini = 127.793 uV, v_off_fin = 110.666 uV 16:32:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.585 uVs 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 103.021 uV, v_off_fin = 117.248 uV 16:32:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 185.449 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 112.169 uV, v_off_fin = 117.259 uV 16:32:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -205.266 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 112.719 uV, v_off_fin = 110.212 uV 16:32:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 183.841 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 101.062 uV, v_off_fin = 98.681 uV 16:33:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -186.177 uVs 16:33:07 Integrated Voltage Measurement... 16:33:16 Voltage Offset Correction: v_off_ini = 104.037 uV, v_off_fin = 107.837 uV 16:33:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 180.446 uVs 16:33:20 I1X Average and RMS of Measurements VT = -188.461 +- 4.638 uVs I1X = 37.698 +- 0.928 uTm 16:33:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:27 Integrated Voltage Measurement... 16:33:36 Voltage Offset Correction: v_off_ini = 100.157 uV, v_off_fin = 90.143 uV 16:33:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -193.967 uVs 16:33:36 Integrated Voltage Measurement... 16:33:45 Voltage Offset Correction: v_off_ini = 96.712 uV, v_off_fin = 105.084 uV 16:33:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.834 uVs 16:33:45 Integrated Voltage Measurement... 16:33:54 Voltage Offset Correction: v_off_ini = 76.974 uV, v_off_fin = 73.492 uV 16:33:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.209 uVs 16:33:54 Integrated Voltage Measurement... 16:34:03 Voltage Offset Correction: v_off_ini = 95.448 uV, v_off_fin = 104.787 uV 16:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.381 uVs 16:34:03 Integrated Voltage Measurement... 16:34:12 Voltage Offset Correction: v_off_ini = 93.988 uV, v_off_fin = 66.021 uV 16:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.335 uVs 16:34:12 Integrated Voltage Measurement... 16:34:20 Voltage Offset Correction: v_off_ini = 93.538 uV, v_off_fin = 109.782 uV 16:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.891 uVs 16:34:25 I1Y Average and RMS of Measurements VT = -193.436 +- 3.407 uVs I1Y = -38.686 +- 0.680 uTm 16:34:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:32 Integrated Voltage Measurement... 16:34:41 Voltage Offset Correction: v_off_ini = 90.137 uV, v_off_fin = 66.742 uV 16:34:41 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -184.100 uVs 16:34:41 Integrated Voltage Measurement... 16:34:50 Voltage Offset Correction: v_off_ini = 98.539 uV, v_off_fin = 107.096 uV 16:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 178.087 uVs 16:34:50 Integrated Voltage Measurement... 16:34:59 Voltage Offset Correction: v_off_ini = 91.743 uV, v_off_fin = 72.214 uV 16:34:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -187.844 uVs 16:34:59 Integrated Voltage Measurement... 16:35:08 Voltage Offset Correction: v_off_ini = 98.087 uV, v_off_fin = 104.976 uV 16:35:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 164.069 uVs 16:35:09 Integrated Voltage Measurement... 16:35:17 Voltage Offset Correction: v_off_ini = 87.790 uV, v_off_fin = 93.176 uV 16:35:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -178.002 uVs 16:35:18 Integrated Voltage Measurement... 16:35:27 Voltage Offset Correction: v_off_ini = 104.271 uV, v_off_fin = 94.536 uV 16:35:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.115 uVs 16:35:29 I2X Average and RMS of Measurements VT = -172.869 +- 8.268 uVs I2X = 15.904 +- 0.760 uTm^2 16:35:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:37 Integrated Voltage Measurement... 16:35:46 Voltage Offset Correction: v_off_ini = 85.160 uV, v_off_fin = 85.153 uV 16:35:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.786 uVs 16:35:46 Integrated Voltage Measurement... 16:35:55 Voltage Offset Correction: v_off_ini = 72.129 uV, v_off_fin = 74.795 uV 16:35:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.682 uVs 16:35:55 Integrated Voltage Measurement... 16:36:04 Voltage Offset Correction: v_off_ini = 88.513 uV, v_off_fin = 88.313 uV 16:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.793 uVs 16:36:04 Integrated Voltage Measurement... 16:36:13 Voltage Offset Correction: v_off_ini = 79.419 uV, v_off_fin = 74.565 uV 16:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.290 uVs 16:36:13 Integrated Voltage Measurement... 16:36:22 Voltage Offset Correction: v_off_ini = 71.951 uV, v_off_fin = 88.199 uV 16:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.089 uVs 16:36:22 Integrated Voltage Measurement... 16:36:31 Voltage Offset Correction: v_off_ini = 101.342 uV, v_off_fin = 104.922 uV 16:36:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.880 uVs 16:36:33 I2Y Average and RMS of Measurements VT = -350.587 +- 7.014 uVs I2Y = -32.254 +- 0.645 uTm^2 16:36:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:49 Integrated Voltage Measurement... 16:36:58 Voltage Offset Correction: v_off_ini = 105.469 uV, v_off_fin = 100.626 uV 16:36:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.567 uVs 16:36:58 Integrated Voltage Measurement... 16:37:07 Voltage Offset Correction: v_off_ini = 112.556 uV, v_off_fin = 101.500 uV 16:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.753 uVs 16:37:07 Integrated Voltage Measurement... 16:37:16 Voltage Offset Correction: v_off_ini = 110.006 uV, v_off_fin = 101.857 uV 16:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -203.412 uVs 16:37:16 Integrated Voltage Measurement... 16:37:25 Voltage Offset Correction: v_off_ini = 100.194 uV, v_off_fin = 92.853 uV 16:37:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.178 uVs 16:37:25 Integrated Voltage Measurement... 16:37:34 Voltage Offset Correction: v_off_ini = 93.760 uV, v_off_fin = 93.154 uV 16:37:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -183.538 uVs 16:37:34 Integrated Voltage Measurement... 16:37:43 Voltage Offset Correction: v_off_ini = 94.268 uV, v_off_fin = 106.576 uV 16:37:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 189.450 uVs 16:37:47 I1X Average and RMS of Measurements VT = -180.983 +- 10.217 uVs I1X = 36.199 +- 2.045 uTm 16:37:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:54 Integrated Voltage Measurement... 16:38:03 Voltage Offset Correction: v_off_ini = 104.367 uV, v_off_fin = 88.507 uV 16:38:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -191.354 uVs 16:38:03 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = 94.291 uV, v_off_fin = 115.215 uV 16:38:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.074 uVs 16:38:12 Integrated Voltage Measurement... 16:38:21 Voltage Offset Correction: v_off_ini = 97.707 uV, v_off_fin = 85.913 uV 16:38:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.148 uVs 16:38:21 Integrated Voltage Measurement... 16:38:30 Voltage Offset Correction: v_off_ini = 104.613 uV, v_off_fin = 113.889 uV 16:38:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.600 uVs 16:38:30 Integrated Voltage Measurement... 16:38:39 Voltage Offset Correction: v_off_ini = 92.696 uV, v_off_fin = 84.112 uV 16:38:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.437 uVs 16:38:39 Integrated Voltage Measurement... 16:38:48 Voltage Offset Correction: v_off_ini = 101.295 uV, v_off_fin = 108.524 uV 16:38:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.182 uVs 16:38:52 I1Y Average and RMS of Measurements VT = -186.632 +- 2.186 uVs I1Y = -37.326 +- 0.439 uTm 16:38:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:00 Integrated Voltage Measurement... 16:39:09 Voltage Offset Correction: v_off_ini = 92.127 uV, v_off_fin = 90.015 uV 16:39:09 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -177.570 uVs 16:39:09 Integrated Voltage Measurement... 16:39:18 Voltage Offset Correction: v_off_ini = 92.711 uV, v_off_fin = 113.656 uV 16:39:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.839 uVs 16:39:18 Integrated Voltage Measurement... 16:39:27 Voltage Offset Correction: v_off_ini = 103.565 uV, v_off_fin = 100.731 uV 16:39:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.208 uVs 16:39:27 Integrated Voltage Measurement... 16:39:36 Voltage Offset Correction: v_off_ini = 105.673 uV, v_off_fin = 105.284 uV 16:39:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.024 uVs 16:39:36 Integrated Voltage Measurement... 16:39:45 Voltage Offset Correction: v_off_ini = 81.094 uV, v_off_fin = 82.080 uV 16:39:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -171.062 uVs 16:39:45 Integrated Voltage Measurement... 16:39:54 Voltage Offset Correction: v_off_ini = 93.407 uV, v_off_fin = 91.273 uV 16:39:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 198.849 uVs 16:39:57 I2X Average and RMS of Measurements VT = -174.259 +- 7.900 uVs I2X = 16.031 +- 0.727 uTm^2 16:40:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:05 Integrated Voltage Measurement... 16:40:14 Voltage Offset Correction: v_off_ini = 97.554 uV, v_off_fin = 91.556 uV 16:40:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.348 uVs 16:40:14 Integrated Voltage Measurement... 16:40:23 Voltage Offset Correction: v_off_ini = 95.995 uV, v_off_fin = 94.161 uV 16:40:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.107 uVs 16:40:23 Integrated Voltage Measurement... 16:40:32 Voltage Offset Correction: v_off_ini = 106.443 uV, v_off_fin = 93.890 uV 16:40:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.365 uVs 16:40:32 Integrated Voltage Measurement... 16:40:41 Voltage Offset Correction: v_off_ini = 95.045 uV, v_off_fin = 92.512 uV 16:40:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.179 uVs 16:40:41 Integrated Voltage Measurement... 16:40:50 Voltage Offset Correction: v_off_ini = 93.888 uV, v_off_fin = 86.214 uV 16:40:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.987 uVs 16:40:50 Integrated Voltage Measurement... 16:40:59 Voltage Offset Correction: v_off_ini = 94.627 uV, v_off_fin = 98.005 uV 16:40:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.638 uVs 16:41:01 I2Y Average and RMS of Measurements VT = -329.104 +- 3.509 uVs I2Y = -30.278 +- 0.323 uTm^2 16:41:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:17 Integrated Voltage Measurement... 16:41:26 Voltage Offset Correction: v_off_ini = 91.457 uV, v_off_fin = 90.392 uV 16:41:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -193.440 uVs 16:41:26 Integrated Voltage Measurement... 16:41:35 Voltage Offset Correction: v_off_ini = 113.403 uV, v_off_fin = 83.301 uV 16:41:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.503 uVs 16:41:35 Integrated Voltage Measurement... 16:41:44 Voltage Offset Correction: v_off_ini = 92.409 uV, v_off_fin = 87.897 uV 16:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -190.315 uVs 16:41:44 Integrated Voltage Measurement... 16:41:53 Voltage Offset Correction: v_off_ini = 76.795 uV, v_off_fin = 79.328 uV 16:41:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 174.703 uVs 16:41:53 Integrated Voltage Measurement... 16:42:02 Voltage Offset Correction: v_off_ini = 79.907 uV, v_off_fin = 84.215 uV 16:42:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.062 uVs 16:42:02 Integrated Voltage Measurement... 16:42:11 Voltage Offset Correction: v_off_ini = 87.549 uV, v_off_fin = 92.273 uV 16:42:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.672 uVs 16:42:16 I1X Average and RMS of Measurements VT = -177.115 +- 3.840 uVs I1X = 35.424 +- 0.769 uTm 16:42:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = 71.831 uV, v_off_fin = 61.728 uV 16:42:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.722 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = 73.222 uV, v_off_fin = 96.218 uV 16:42:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.691 uVs 16:42:40 Integrated Voltage Measurement... 16:42:49 Voltage Offset Correction: v_off_ini = 77.670 uV, v_off_fin = 59.751 uV 16:42:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.572 uVs 16:42:49 Integrated Voltage Measurement... 16:42:58 Voltage Offset Correction: v_off_ini = 79.380 uV, v_off_fin = 85.236 uV 16:42:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.234 uVs 16:42:58 Integrated Voltage Measurement... 16:43:07 Voltage Offset Correction: v_off_ini = 68.024 uV, v_off_fin = 70.689 uV 16:43:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.719 uVs 16:43:07 Integrated Voltage Measurement... 16:43:16 Voltage Offset Correction: v_off_ini = 73.170 uV, v_off_fin = 88.226 uV 16:43:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.241 uVs 16:43:21 I1Y Average and RMS of Measurements VT = -185.696 +- 2.269 uVs I1Y = -37.137 +- 0.453 uTm 16:43:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:28 Integrated Voltage Measurement... 16:43:37 Voltage Offset Correction: v_off_ini = 55.752 uV, v_off_fin = 51.792 uV 16:43:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -169.479 uVs 16:43:37 Integrated Voltage Measurement... 16:43:46 Voltage Offset Correction: v_off_ini = 73.694 uV, v_off_fin = 76.017 uV 16:43:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 154.463 uVs 16:43:46 Integrated Voltage Measurement... 16:43:55 Voltage Offset Correction: v_off_ini = 67.454 uV, v_off_fin = 46.069 uV 16:43:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -151.956 uVs 16:43:56 Integrated Voltage Measurement... 16:44:05 Voltage Offset Correction: v_off_ini = 74.459 uV, v_off_fin = 76.642 uV 16:44:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.315 uVs 16:44:05 Integrated Voltage Measurement... 16:44:14 Voltage Offset Correction: v_off_ini = 68.158 uV, v_off_fin = 61.240 uV 16:44:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.843 uVs 16:44:14 Integrated Voltage Measurement... 16:44:23 Voltage Offset Correction: v_off_ini = 75.121 uV, v_off_fin = 74.739 uV 16:44:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 179.372 uVs 16:44:25 I2X Average and RMS of Measurements VT = -168.071 +- 5.931 uVs I2X = 15.463 +- 0.546 uTm^2 16:44:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:33 Integrated Voltage Measurement... 16:44:42 Voltage Offset Correction: v_off_ini = 46.391 uV, v_off_fin = 57.138 uV 16:44:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.777 uVs 16:44:42 Integrated Voltage Measurement... 16:44:51 Voltage Offset Correction: v_off_ini = 67.019 uV, v_off_fin = 57.579 uV 16:44:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.167 uVs 16:44:51 Integrated Voltage Measurement... 16:45:00 Voltage Offset Correction: v_off_ini = 57.391 uV, v_off_fin = 45.873 uV 16:45:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.376 uVs 16:45:00 Integrated Voltage Measurement... 16:45:09 Voltage Offset Correction: v_off_ini = 61.814 uV, v_off_fin = 65.677 uV 16:45:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.735 uVs 16:45:09 Integrated Voltage Measurement... 16:45:18 Voltage Offset Correction: v_off_ini = 60.852 uV, v_off_fin = 51.316 uV 16:45:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.222 uVs 16:45:18 Integrated Voltage Measurement... 16:45:27 Voltage Offset Correction: v_off_ini = 53.652 uV, v_off_fin = 50.998 uV 16:45:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.351 uVs 16:45:29 I2Y Average and RMS of Measurements VT = -308.771 +- 1.545 uVs I2Y = -28.407 +- 0.142 uTm^2 16:45:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:48 Integrated Voltage Measurement... 16:45:57 Voltage Offset Correction: v_off_ini = 61.929 uV, v_off_fin = 52.863 uV 16:45:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.075 uVs 16:45:57 Integrated Voltage Measurement... 16:46:06 Voltage Offset Correction: v_off_ini = 78.967 uV, v_off_fin = 72.663 uV 16:46:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 187.947 uVs 16:46:06 Integrated Voltage Measurement... 16:46:15 Voltage Offset Correction: v_off_ini = 62.090 uV, v_off_fin = 60.698 uV 16:46:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.430 uVs 16:46:15 Integrated Voltage Measurement... 16:46:24 Voltage Offset Correction: v_off_ini = 66.916 uV, v_off_fin = 71.747 uV 16:46:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.986 uVs 16:46:24 Integrated Voltage Measurement... 16:46:33 Voltage Offset Correction: v_off_ini = 74.478 uV, v_off_fin = 73.892 uV 16:46:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -178.221 uVs 16:46:33 Integrated Voltage Measurement... 16:46:42 Voltage Offset Correction: v_off_ini = 71.882 uV, v_off_fin = 67.667 uV 16:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 183.791 uVs 16:46:46 I1X Average and RMS of Measurements VT = -180.908 +- 2.574 uVs I1X = 36.183 +- 0.515 uTm 16:46:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:53 Integrated Voltage Measurement... 16:47:02 Voltage Offset Correction: v_off_ini = 69.579 uV, v_off_fin = 58.465 uV 16:47:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.099 uVs 16:47:02 Integrated Voltage Measurement... 16:47:11 Voltage Offset Correction: v_off_ini = 68.691 uV, v_off_fin = 84.232 uV 16:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 171.786 uVs 16:47:11 Integrated Voltage Measurement... 16:47:20 Voltage Offset Correction: v_off_ini = 65.547 uV, v_off_fin = 54.710 uV 16:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.442 uVs 16:47:20 Integrated Voltage Measurement... 16:47:29 Voltage Offset Correction: v_off_ini = 59.198 uV, v_off_fin = 62.392 uV 16:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 175.228 uVs 16:47:29 Integrated Voltage Measurement... 16:47:38 Voltage Offset Correction: v_off_ini = 76.194 uV, v_off_fin = 48.995 uV 16:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.715 uVs 16:47:38 Integrated Voltage Measurement... 16:47:47 Voltage Offset Correction: v_off_ini = 49.951 uV, v_off_fin = 63.572 uV 16:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.572 uVs 16:47:51 I1Y Average and RMS of Measurements VT = -178.807 +- 5.789 uVs I1Y = -35.760 +- 1.159 uTm 16:47:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:59 Integrated Voltage Measurement... 16:48:08 Voltage Offset Correction: v_off_ini = 44.483 uV, v_off_fin = 36.572 uV 16:48:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -158.976 uVs 16:48:08 Integrated Voltage Measurement... 16:48:17 Voltage Offset Correction: v_off_ini = 55.727 uV, v_off_fin = 61.182 uV 16:48:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.711 uVs 16:48:17 Integrated Voltage Measurement... 16:48:26 Voltage Offset Correction: v_off_ini = 48.469 uV, v_off_fin = 40.284 uV 16:48:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.684 uVs 16:48:26 Integrated Voltage Measurement... 16:48:35 Voltage Offset Correction: v_off_ini = 69.443 uV, v_off_fin = 67.482 uV 16:48:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 150.171 uVs 16:48:35 Integrated Voltage Measurement... 16:48:44 Voltage Offset Correction: v_off_ini = 41.998 uV, v_off_fin = 32.837 uV 16:48:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -160.483 uVs 16:48:44 Integrated Voltage Measurement... 16:48:53 Voltage Offset Correction: v_off_ini = 38.279 uV, v_off_fin = 40.500 uV 16:48:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 171.064 uVs 16:48:55 I2X Average and RMS of Measurements VT = -161.348 +- 4.125 uVs I2X = 14.844 +- 0.381 uTm^2 16:49:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:03 Integrated Voltage Measurement... 16:49:12 Voltage Offset Correction: v_off_ini = 41.401 uV, v_off_fin = 36.815 uV 16:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.880 uVs 16:49:12 Integrated Voltage Measurement... 16:49:21 Voltage Offset Correction: v_off_ini = 34.827 uV, v_off_fin = 32.975 uV 16:49:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.633 uVs 16:49:21 Integrated Voltage Measurement... 16:49:30 Voltage Offset Correction: v_off_ini = 29.353 uV, v_off_fin = 39.123 uV 16:49:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.425 uVs 16:49:30 Integrated Voltage Measurement... 16:49:39 Voltage Offset Correction: v_off_ini = 37.679 uV, v_off_fin = 27.363 uV 16:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.424 uVs 16:49:39 Integrated Voltage Measurement... 16:49:48 Voltage Offset Correction: v_off_ini = 33.467 uV, v_off_fin = 29.588 uV 16:49:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.099 uVs 16:49:48 Integrated Voltage Measurement... 16:49:57 Voltage Offset Correction: v_off_ini = 43.438 uV, v_off_fin = 40.331 uV 16:49:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.796 uVs 16:50:00 I2Y Average and RMS of Measurements VT = -284.876 +- 4.158 uVs I2Y = -26.209 +- 0.383 uTm^2 16:50:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:18 Integrated Voltage Measurement... 16:50:27 Voltage Offset Correction: v_off_ini = 44.804 uV, v_off_fin = 28.776 uV 16:50:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.152 uVs 16:50:27 Integrated Voltage Measurement... 16:50:36 Voltage Offset Correction: v_off_ini = 36.372 uV, v_off_fin = 33.943 uV 16:50:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.361 uVs 16:50:36 Integrated Voltage Measurement... 16:50:45 Voltage Offset Correction: v_off_ini = 31.420 uV, v_off_fin = 28.645 uV 16:50:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.458 uVs 16:50:45 Integrated Voltage Measurement... 16:50:54 Voltage Offset Correction: v_off_ini = 37.429 uV, v_off_fin = 29.483 uV 16:50:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.839 uVs 16:50:54 Integrated Voltage Measurement... 16:51:03 Voltage Offset Correction: v_off_ini = 30.185 uV, v_off_fin = 37.209 uV 16:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -157.866 uVs 16:51:03 Integrated Voltage Measurement... 16:51:12 Voltage Offset Correction: v_off_ini = 42.361 uV, v_off_fin = 47.182 uV 16:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.438 uVs 16:51:16 I1X Average and RMS of Measurements VT = -162.186 +- 4.217 uVs I1X = 32.438 +- 0.843 uTm 16:51:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:23 Integrated Voltage Measurement... 16:51:32 Voltage Offset Correction: v_off_ini = 40.547 uV, v_off_fin = 17.285 uV 16:51:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.327 uVs 16:51:32 Integrated Voltage Measurement... 16:51:41 Voltage Offset Correction: v_off_ini = 29.639 uV, v_off_fin = 41.118 uV 16:51:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.703 uVs 16:51:41 Integrated Voltage Measurement... 16:51:50 Voltage Offset Correction: v_off_ini = 34.205 uV, v_off_fin = 17.611 uV 16:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.942 uVs 16:51:50 Integrated Voltage Measurement... 16:51:59 Voltage Offset Correction: v_off_ini = 20.915 uV, v_off_fin = 32.656 uV 16:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.351 uVs 16:51:59 Integrated Voltage Measurement... 16:52:08 Voltage Offset Correction: v_off_ini = 39.190 uV, v_off_fin = 11.843 uV 16:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.488 uVs 16:52:08 Integrated Voltage Measurement... 16:52:17 Voltage Offset Correction: v_off_ini = 25.679 uV, v_off_fin = 30.029 uV 16:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.021 uVs 16:52:22 I1Y Average and RMS of Measurements VT = -187.139 +- 3.017 uVs I1Y = -37.426 +- 0.603 uTm 16:52:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:29 Integrated Voltage Measurement... 16:52:38 Voltage Offset Correction: v_off_ini = 15.569 uV, v_off_fin = 9.144 uV 16:52:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -137.515 uVs 16:52:38 Integrated Voltage Measurement... 16:52:47 Voltage Offset Correction: v_off_ini = 25.695 uV, v_off_fin = 39.654 uV 16:52:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.896 uVs 16:52:47 Integrated Voltage Measurement... 16:52:56 Voltage Offset Correction: v_off_ini = 25.889 uV, v_off_fin = 24.919 uV 16:52:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -162.827 uVs 16:52:56 Integrated Voltage Measurement... 16:53:05 Voltage Offset Correction: v_off_ini = 38.790 uV, v_off_fin = 29.182 uV 16:53:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.317 uVs 16:53:05 Integrated Voltage Measurement... 16:53:14 Voltage Offset Correction: v_off_ini = 22.179 uV, v_off_fin = 5.136 uV 16:53:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.185 uVs 16:53:14 Integrated Voltage Measurement... 16:53:23 Voltage Offset Correction: v_off_ini = 22.156 uV, v_off_fin = 27.677 uV 16:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.200 uVs 16:53:26 I2X Average and RMS of Measurements VT = -152.823 +- 1.852 uVs I2X = 14.060 +- 0.171 uTm^2 16:53:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:34 Integrated Voltage Measurement... 16:53:43 Voltage Offset Correction: v_off_ini = 38.076 uV, v_off_fin = 29.870 uV 16:53:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.911 uVs 16:53:43 Integrated Voltage Measurement... 16:53:52 Voltage Offset Correction: v_off_ini = 25.630 uV, v_off_fin = 18.882 uV 16:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.763 uVs 16:53:52 Integrated Voltage Measurement... 16:54:01 Voltage Offset Correction: v_off_ini = 4.488 uV, v_off_fin = 0.552 uV 16:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.279 uVs 16:54:01 Integrated Voltage Measurement... 16:54:10 Voltage Offset Correction: v_off_ini = 6.005 uV, v_off_fin = 13.177 uV 16:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.176 uVs 16:54:10 Integrated Voltage Measurement... 16:54:19 Voltage Offset Correction: v_off_ini = 0.926 uV, v_off_fin = 8.766 uV 16:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.361 uVs 16:54:19 Integrated Voltage Measurement... 16:54:28 Voltage Offset Correction: v_off_ini = 9.541 uV, v_off_fin = 12.940 uV 16:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.385 uVs 16:54:30 I2Y Average and RMS of Measurements VT = -278.313 +- 9.011 uVs I2Y = -25.605 +- 0.829 uTm^2 16:54:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:49 Integrated Voltage Measurement... 16:54:58 Voltage Offset Correction: v_off_ini = 18.387 uV, v_off_fin = -7.720 uV 16:54:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -165.524 uVs 16:54:58 Integrated Voltage Measurement... 16:55:07 Voltage Offset Correction: v_off_ini = 1.363 uV, v_off_fin = -3.589 uV 16:55:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.856 uVs 16:55:07 Integrated Voltage Measurement... 16:55:16 Voltage Offset Correction: v_off_ini = -13.260 uV, v_off_fin = -7.341 uV 16:55:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.107 uVs 16:55:16 Integrated Voltage Measurement... 16:55:25 Voltage Offset Correction: v_off_ini = -1.514 uV, v_off_fin = -1.925 uV 16:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.155 uVs 16:55:25 Integrated Voltage Measurement... 16:55:34 Voltage Offset Correction: v_off_ini = -2.596 uV, v_off_fin = -2.932 uV 16:55:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -150.500 uVs 16:55:34 Integrated Voltage Measurement... 16:55:43 Voltage Offset Correction: v_off_ini = -0.922 uV, v_off_fin = 16.019 uV 16:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 141.284 uVs 16:55:47 I1X Average and RMS of Measurements VT = -144.238 +- 4.467 uVs I1X = 28.850 +- 0.894 uTm 16:55:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:54 Integrated Voltage Measurement... 16:56:03 Voltage Offset Correction: v_off_ini = -3.199 uV, v_off_fin = 1.625 uV 16:56:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.996 uVs 16:56:03 Integrated Voltage Measurement... 16:56:11 Voltage Offset Correction: v_off_ini = 14.014 uV, v_off_fin = 33.563 uV 16:56:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.025 uVs 16:56:12 Integrated Voltage Measurement... 16:56:20 Voltage Offset Correction: v_off_ini = 21.164 uV, v_off_fin = 21.170 uV 16:56:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.348 uVs 16:56:21 Integrated Voltage Measurement... 16:56:29 Voltage Offset Correction: v_off_ini = 1.887 uV, v_off_fin = 22.707 uV 16:56:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.540 uVs 16:56:30 Integrated Voltage Measurement... 16:56:38 Voltage Offset Correction: v_off_ini = 10.516 uV, v_off_fin = 2.272 uV 16:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.686 uVs 16:56:39 Integrated Voltage Measurement... 16:56:47 Voltage Offset Correction: v_off_ini = 2.174 uV, v_off_fin = 27.687 uV 16:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.646 uVs 16:56:52 I1Y Average and RMS of Measurements VT = -197.207 +- 8.061 uVs I1Y = -39.440 +- 1.611 uTm 16:56:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:59 Integrated Voltage Measurement... 16:57:08 Voltage Offset Correction: v_off_ini = 17.435 uV, v_off_fin = -1.600 uV 16:57:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -147.515 uVs 16:57:08 Integrated Voltage Measurement... 16:57:17 Voltage Offset Correction: v_off_ini = 13.962 uV, v_off_fin = 24.034 uV 16:57:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 140.854 uVs 16:57:17 Integrated Voltage Measurement... 16:57:26 Voltage Offset Correction: v_off_ini = 17.020 uV, v_off_fin = 8.663 uV 16:57:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -135.696 uVs 16:57:26 Integrated Voltage Measurement... 16:57:35 Voltage Offset Correction: v_off_ini = 14.197 uV, v_off_fin = 25.950 uV 16:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.713 uVs 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = 25.339 uV, v_off_fin = 19.498 uV 16:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.528 uVs 16:57:45 Integrated Voltage Measurement... 16:57:53 Voltage Offset Correction: v_off_ini = 36.515 uV, v_off_fin = 26.495 uV 16:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.456 uVs 16:57:56 I2X Average and RMS of Measurements VT = -142.293 +- 1.736 uVs I2X = 13.091 +- 0.160 uTm^2 16:58:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:04 Integrated Voltage Measurement... 16:58:13 Voltage Offset Correction: v_off_ini = 18.653 uV, v_off_fin = 39.825 uV 16:58:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.804 uVs 16:58:13 Integrated Voltage Measurement... 16:58:22 Voltage Offset Correction: v_off_ini = 17.671 uV, v_off_fin = 24.675 uV 16:58:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.308 uVs 16:58:22 Integrated Voltage Measurement... 16:58:31 Voltage Offset Correction: v_off_ini = 31.453 uV, v_off_fin = 25.944 uV 16:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.675 uVs 16:58:31 Integrated Voltage Measurement... 16:58:40 Voltage Offset Correction: v_off_ini = 22.955 uV, v_off_fin = 31.919 uV 16:58:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.140 uVs 16:58:40 Integrated Voltage Measurement... 16:58:49 Voltage Offset Correction: v_off_ini = 39.607 uV, v_off_fin = 27.549 uV 16:58:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.106 uVs 16:58:49 Integrated Voltage Measurement... 16:58:58 Voltage Offset Correction: v_off_ini = 29.611 uV, v_off_fin = 29.769 uV 16:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.503 uVs 16:59:00 I2Y Average and RMS of Measurements VT = -278.923 +- 6.001 uVs I2Y = -25.661 +- 0.552 uTm^2 16:59:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:18 Integrated Voltage Measurement... 16:59:27 Voltage Offset Correction: v_off_ini = 41.022 uV, v_off_fin = 32.096 uV 16:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.178 uVs 16:59:27 Integrated Voltage Measurement... 16:59:36 Voltage Offset Correction: v_off_ini = 46.446 uV, v_off_fin = 34.712 uV 16:59:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.513 uVs 16:59:36 Integrated Voltage Measurement... 16:59:45 Voltage Offset Correction: v_off_ini = 39.852 uV, v_off_fin = 33.459 uV 16:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.737 uVs 16:59:45 Integrated Voltage Measurement... 16:59:54 Voltage Offset Correction: v_off_ini = 36.261 uV, v_off_fin = 41.039 uV 16:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.396 uVs 16:59:54 Integrated Voltage Measurement... 17:00:03 Voltage Offset Correction: v_off_ini = 44.949 uV, v_off_fin = 40.243 uV 17:00:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.171 uVs 17:00:03 Integrated Voltage Measurement... 17:00:12 Voltage Offset Correction: v_off_ini = 48.146 uV, v_off_fin = 47.020 uV 17:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.236 uVs 17:00:17 I1X Average and RMS of Measurements VT = -141.872 +- 5.149 uVs I1X = 28.375 +- 1.031 uTm 17:00:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:23 Integrated Voltage Measurement... 17:00:32 Voltage Offset Correction: v_off_ini = 18.095 uV, v_off_fin = 15.458 uV 17:00:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.225 uVs 17:00:32 Integrated Voltage Measurement... 17:00:41 Voltage Offset Correction: v_off_ini = 30.817 uV, v_off_fin = 33.611 uV 17:00:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.428 uVs 17:00:41 Integrated Voltage Measurement... 17:00:50 Voltage Offset Correction: v_off_ini = 14.926 uV, v_off_fin = 3.382 uV 17:00:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.349 uVs 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = 7.741 uV, v_off_fin = 23.986 uV 17:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.373 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = 17.972 uV, v_off_fin = 5.658 uV 17:01:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.958 uVs 17:01:08 Integrated Voltage Measurement... 17:01:17 Voltage Offset Correction: v_off_ini = 27.543 uV, v_off_fin = 25.888 uV 17:01:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.328 uVs 17:01:22 I1Y Average and RMS of Measurements VT = -195.944 +- 4.123 uVs I1Y = -39.189 +- 0.825 uTm 17:01:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:29 Integrated Voltage Measurement... 17:01:38 Voltage Offset Correction: v_off_ini = 4.720 uV, v_off_fin = 2.881 uV 17:01:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.154 uVs 17:01:38 Integrated Voltage Measurement... 17:01:47 Voltage Offset Correction: v_off_ini = -1.921 uV, v_off_fin = 17.409 uV 17:01:47 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 143.874 uVs 17:01:47 Integrated Voltage Measurement... 17:01:56 Voltage Offset Correction: v_off_ini = 5.963 uV, v_off_fin = 8.632 uV 17:01:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -154.247 uVs 17:01:56 Integrated Voltage Measurement... 17:02:05 Voltage Offset Correction: v_off_ini = 4.800 uV, v_off_fin = 10.440 uV 17:02:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.055 uVs 17:02:05 Integrated Voltage Measurement... 17:02:14 Voltage Offset Correction: v_off_ini = 8.281 uV, v_off_fin = -3.678 uV 17:02:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.705 uVs 17:02:14 Integrated Voltage Measurement... 17:02:23 Voltage Offset Correction: v_off_ini = 3.472 uV, v_off_fin = 11.997 uV 17:02:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.772 uVs 17:02:26 I2X Average and RMS of Measurements VT = -137.135 +- 4.852 uVs I2X = 12.617 +- 0.446 uTm^2 17:02:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = 23.215 uV, v_off_fin = 14.147 uV 17:02:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -261.530 uVs 17:02:42 Integrated Voltage Measurement... 17:02:51 Voltage Offset Correction: v_off_ini = 13.040 uV, v_off_fin = 23.286 uV 17:02:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.888 uVs 17:02:51 Integrated Voltage Measurement... 17:03:00 Voltage Offset Correction: v_off_ini = 22.332 uV, v_off_fin = 26.017 uV 17:03:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.284 uVs 17:03:01 Integrated Voltage Measurement... 17:03:09 Voltage Offset Correction: v_off_ini = 54.411 uV, v_off_fin = 35.245 uV 17:03:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.539 uVs 17:03:10 Integrated Voltage Measurement... 17:03:19 Voltage Offset Correction: v_off_ini = 18.840 uV, v_off_fin = 31.145 uV 17:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.687 uVs 17:03:19 Integrated Voltage Measurement... 17:03:28 Voltage Offset Correction: v_off_ini = 22.949 uV, v_off_fin = 32.085 uV 17:03:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.775 uVs 17:03:30 I2Y Average and RMS of Measurements VT = -273.784 +- 6.085 uVs I2Y = -25.189 +- 0.560 uTm^2 17:03:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:48 Integrated Voltage Measurement... 17:03:57 Voltage Offset Correction: v_off_ini = 46.204 uV, v_off_fin = 16.141 uV 17:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.846 uVs 17:03:57 Integrated Voltage Measurement... 17:04:06 Voltage Offset Correction: v_off_ini = 41.294 uV, v_off_fin = 50.604 uV 17:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.705 uVs 17:04:06 Integrated Voltage Measurement... 17:04:15 Voltage Offset Correction: v_off_ini = 34.438 uV, v_off_fin = 30.225 uV 17:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.345 uVs 17:04:15 Integrated Voltage Measurement... 17:04:24 Voltage Offset Correction: v_off_ini = 17.905 uV, v_off_fin = 13.769 uV 17:04:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.999 uVs 17:04:24 Integrated Voltage Measurement... 17:04:33 Voltage Offset Correction: v_off_ini = 31.442 uV, v_off_fin = 23.813 uV 17:04:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -127.946 uVs 17:04:33 Integrated Voltage Measurement... 17:04:42 Voltage Offset Correction: v_off_ini = 18.210 uV, v_off_fin = 17.564 uV 17:04:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.492 uVs 17:04:47 I1X Average and RMS of Measurements VT = -132.889 +- 6.848 uVs I1X = 26.580 +- 1.369 uTm 17:04:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:53 Integrated Voltage Measurement... 17:05:02 Voltage Offset Correction: v_off_ini = 29.753 uV, v_off_fin = 21.362 uV 17:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -212.132 uVs 17:05:02 Integrated Voltage Measurement... 17:05:11 Voltage Offset Correction: v_off_ini = 18.965 uV, v_off_fin = 34.644 uV 17:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.396 uVs 17:05:11 Integrated Voltage Measurement... 17:05:20 Voltage Offset Correction: v_off_ini = 34.025 uV, v_off_fin = 12.683 uV 17:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.887 uVs 17:05:20 Integrated Voltage Measurement... 17:05:29 Voltage Offset Correction: v_off_ini = 36.853 uV, v_off_fin = 32.047 uV 17:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.344 uVs 17:05:29 Integrated Voltage Measurement... 17:05:38 Voltage Offset Correction: v_off_ini = 31.822 uV, v_off_fin = 21.933 uV 17:05:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.741 uVs 17:05:38 Integrated Voltage Measurement... 17:05:47 Voltage Offset Correction: v_off_ini = 37.520 uV, v_off_fin = 42.278 uV 17:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.810 uVs 17:05:51 I1Y Average and RMS of Measurements VT = -210.718 +- 1.152 uVs I1Y = -42.144 +- 0.231 uTm 17:05:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:59 Integrated Voltage Measurement... 17:06:08 Voltage Offset Correction: v_off_ini = 34.315 uV, v_off_fin = 24.500 uV 17:06:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -132.632 uVs 17:06:08 Integrated Voltage Measurement... 17:06:17 Voltage Offset Correction: v_off_ini = 30.908 uV, v_off_fin = 51.204 uV 17:06:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.269 uVs 17:06:17 Integrated Voltage Measurement... 17:06:26 Voltage Offset Correction: v_off_ini = 42.379 uV, v_off_fin = 31.738 uV 17:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.719 uVs 17:06:26 Integrated Voltage Measurement... 17:06:35 Voltage Offset Correction: v_off_ini = 47.015 uV, v_off_fin = 60.964 uV 17:06:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.013 uVs 17:06:35 Integrated Voltage Measurement... 17:06:44 Voltage Offset Correction: v_off_ini = 49.950 uV, v_off_fin = 49.787 uV 17:06:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.651 uVs 17:06:44 Integrated Voltage Measurement... 17:06:53 Voltage Offset Correction: v_off_ini = 42.021 uV, v_off_fin = 48.860 uV 17:06:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.068 uVs 17:06:56 I2X Average and RMS of Measurements VT = -127.225 +- 4.773 uVs I2X = 11.705 +- 0.438 uTm^2 17:07:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:03 Integrated Voltage Measurement... 17:07:12 Voltage Offset Correction: v_off_ini = 37.106 uV, v_off_fin = 41.413 uV 17:07:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.890 uVs 17:07:12 Integrated Voltage Measurement... 17:07:21 Voltage Offset Correction: v_off_ini = 29.036 uV, v_off_fin = 34.484 uV 17:07:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.569 uVs 17:07:21 Integrated Voltage Measurement... 17:07:30 Voltage Offset Correction: v_off_ini = 19.837 uV, v_off_fin = 14.619 uV 17:07:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.287 uVs 17:07:30 Integrated Voltage Measurement... 17:07:39 Voltage Offset Correction: v_off_ini = 29.642 uV, v_off_fin = 24.858 uV 17:07:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.819 uVs 17:07:39 Integrated Voltage Measurement... 17:07:48 Voltage Offset Correction: v_off_ini = 38.077 uV, v_off_fin = 35.024 uV 17:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.039 uVs 17:07:48 Integrated Voltage Measurement... 17:07:57 Voltage Offset Correction: v_off_ini = 43.558 uV, v_off_fin = 29.882 uV 17:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.679 uVs 17:08:00 I2Y Average and RMS of Measurements VT = -279.547 +- 7.289 uVs I2Y = -25.718 +- 0.671 uTm^2 17:08:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:18 Integrated Voltage Measurement... 17:08:27 Voltage Offset Correction: v_off_ini = 35.045 uV, v_off_fin = 30.784 uV 17:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.631 uVs 17:08:27 Integrated Voltage Measurement... 17:08:36 Voltage Offset Correction: v_off_ini = 26.766 uV, v_off_fin = 41.890 uV 17:08:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.322 uVs 17:08:36 Integrated Voltage Measurement... 17:08:45 Voltage Offset Correction: v_off_ini = 38.337 uV, v_off_fin = 30.363 uV 17:08:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.644 uVs 17:08:45 Integrated Voltage Measurement... 17:08:54 Voltage Offset Correction: v_off_ini = 25.512 uV, v_off_fin = 22.977 uV 17:08:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.204 uVs 17:08:54 Integrated Voltage Measurement... 17:09:03 Voltage Offset Correction: v_off_ini = 38.512 uV, v_off_fin = 29.841 uV 17:09:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.258 uVs 17:09:03 Integrated Voltage Measurement... 17:09:12 Voltage Offset Correction: v_off_ini = 28.640 uV, v_off_fin = 36.303 uV 17:09:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.898 uVs 17:09:16 I1X Average and RMS of Measurements VT = -126.660 +- 8.431 uVs I1X = 25.332 +- 1.686 uTm 17:09:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:23 Integrated Voltage Measurement... 17:09:32 Voltage Offset Correction: v_off_ini = 27.923 uV, v_off_fin = 19.159 uV 17:09:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -225.392 uVs 17:09:32 Integrated Voltage Measurement... 17:09:41 Voltage Offset Correction: v_off_ini = 37.636 uV, v_off_fin = 42.453 uV 17:09:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.458 uVs 17:09:41 Integrated Voltage Measurement... 17:09:50 Voltage Offset Correction: v_off_ini = 32.506 uV, v_off_fin = 34.818 uV 17:09:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.033 uVs 17:09:50 Integrated Voltage Measurement... 17:09:59 Voltage Offset Correction: v_off_ini = 30.760 uV, v_off_fin = 71.437 uV 17:09:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.057 uVs 17:09:59 Integrated Voltage Measurement... 17:10:08 Voltage Offset Correction: v_off_ini = 26.944 uV, v_off_fin = 32.926 uV 17:10:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.808 uVs 17:10:08 Integrated Voltage Measurement... 17:10:17 Voltage Offset Correction: v_off_ini = 34.097 uV, v_off_fin = 40.352 uV 17:10:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.152 uVs 17:10:21 I1Y Average and RMS of Measurements VT = -215.317 +- 4.448 uVs I1Y = -43.064 +- 0.891 uTm 17:10:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:29 Integrated Voltage Measurement... 17:10:38 Voltage Offset Correction: v_off_ini = 25.942 uV, v_off_fin = 11.686 uV 17:10:38 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -137.576 uVs 17:10:38 Integrated Voltage Measurement... 17:10:47 Voltage Offset Correction: v_off_ini = 21.464 uV, v_off_fin = 26.607 uV 17:10:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.236 uVs 17:10:47 Integrated Voltage Measurement... 17:10:56 Voltage Offset Correction: v_off_ini = 13.613 uV, v_off_fin = 6.213 uV 17:10:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.063 uVs 17:10:56 Integrated Voltage Measurement... 17:11:05 Voltage Offset Correction: v_off_ini = 6.444 uV, v_off_fin = 14.995 uV 17:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.620 uVs 17:11:05 Integrated Voltage Measurement... 17:11:14 Voltage Offset Correction: v_off_ini = 1.589 uV, v_off_fin = -0.764 uV 17:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.266 uVs 17:11:14 Integrated Voltage Measurement... 17:11:23 Voltage Offset Correction: v_off_ini = 23.103 uV, v_off_fin = 34.018 uV 17:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.065 uVs 17:11:25 I2X Average and RMS of Measurements VT = -120.971 +- 3.844 uVs I2X = 11.129 +- 0.353 uTm^2 17:11:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:33 Integrated Voltage Measurement... 17:11:42 Voltage Offset Correction: v_off_ini = 8.151 uV, v_off_fin = 7.476 uV 17:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.336 uVs 17:11:42 Integrated Voltage Measurement... 17:11:51 Voltage Offset Correction: v_off_ini = 17.116 uV, v_off_fin = 15.550 uV 17:11:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.240 uVs 17:11:51 Integrated Voltage Measurement... 17:12:00 Voltage Offset Correction: v_off_ini = 28.138 uV, v_off_fin = 24.145 uV 17:12:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.468 uVs 17:12:00 Integrated Voltage Measurement... 17:12:09 Voltage Offset Correction: v_off_ini = 17.230 uV, v_off_fin = 21.617 uV 17:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.114 uVs 17:12:09 Integrated Voltage Measurement... 17:12:18 Voltage Offset Correction: v_off_ini = 5.393 uV, v_off_fin = 17.225 uV 17:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.377 uVs 17:12:18 Integrated Voltage Measurement... 17:12:27 Voltage Offset Correction: v_off_ini = 23.325 uV, v_off_fin = 32.641 uV 17:12:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.066 uVs 17:12:30 I2Y Average and RMS of Measurements VT = -271.267 +- 7.249 uVs I2Y = -24.957 +- 0.667 uTm^2 17:12:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm