SLAC Magnetic Measurements Date: 08-08-2025 Time: 12:37:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16342 Dataset Number: 1 Run Purpose: Final Results Run Type: On Axis Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 12:38:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:05 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:38:06 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:38:08 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:38:09 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:38:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:57 Integrated Voltage Measurement... 12:39:06 Voltage Offset Correction: v_off_ini = 685.008 uV, v_off_fin = 675.644 uV 12:39:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.033 uVs 12:39:06 Integrated Voltage Measurement... 12:39:15 Voltage Offset Correction: v_off_ini = 678.828 uV, v_off_fin = 656.029 uV 12:39:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.365 uVs 12:39:15 Integrated Voltage Measurement... 12:39:24 Voltage Offset Correction: v_off_ini = 659.242 uV, v_off_fin = 666.574 uV 12:39:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.440 uVs 12:39:24 Integrated Voltage Measurement... 12:39:33 Voltage Offset Correction: v_off_ini = 673.682 uV, v_off_fin = 660.470 uV 12:39:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.778 uVs 12:39:33 Integrated Voltage Measurement... 12:39:42 Voltage Offset Correction: v_off_ini = 659.078 uV, v_off_fin = 656.593 uV 12:39:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.914 uVs 12:39:42 Integrated Voltage Measurement... 12:39:51 Voltage Offset Correction: v_off_ini = 664.963 uV, v_off_fin = 664.267 uV 12:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.700 uVs 12:39:55 I1X Average and RMS of Measurements VT = -54.038 +- 16.572 uVs I1X = 10.808 +- 3.315 uTm 12:39:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:40:02 Integrated Voltage Measurement... 12:40:11 Voltage Offset Correction: v_off_ini = 656.641 uV, v_off_fin = 644.174 uV 12:40:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.616 uVs 12:40:11 Integrated Voltage Measurement... 12:40:20 Voltage Offset Correction: v_off_ini = 663.539 uV, v_off_fin = 663.851 uV 12:40:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 259.183 uVs 12:40:20 Integrated Voltage Measurement... 12:40:29 Voltage Offset Correction: v_off_ini = 644.741 uV, v_off_fin = 633.415 uV 12:40:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -273.221 uVs 12:40:29 Integrated Voltage Measurement... 12:40:38 Voltage Offset Correction: v_off_ini = 656.213 uV, v_off_fin = 667.768 uV 12:40:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 268.417 uVs 12:40:38 Integrated Voltage Measurement... 12:40:47 Voltage Offset Correction: v_off_ini = 661.656 uV, v_off_fin = 633.826 uV 12:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -268.752 uVs 12:40:47 Integrated Voltage Measurement... 12:40:56 Voltage Offset Correction: v_off_ini = 653.951 uV, v_off_fin = 658.230 uV 12:40:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 270.950 uVs 12:41:00 I1Y Average and RMS of Measurements VT = -267.856 +- 3.527 uVs I1Y = -53.571 +- 0.706 uTm 12:41:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:08 Integrated Voltage Measurement... 12:41:17 Voltage Offset Correction: v_off_ini = 641.718 uV, v_off_fin = 633.467 uV 12:41:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -53.584 uVs 12:41:17 Integrated Voltage Measurement... 12:41:26 Voltage Offset Correction: v_off_ini = 628.902 uV, v_off_fin = 644.867 uV 12:41:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 20.260 uVs 12:41:26 Integrated Voltage Measurement... 12:41:35 Voltage Offset Correction: v_off_ini = 631.394 uV, v_off_fin = 629.853 uV 12:41:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.047 uVs 12:41:35 Integrated Voltage Measurement... 12:41:44 Voltage Offset Correction: v_off_ini = 636.782 uV, v_off_fin = 644.396 uV 12:41:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.627 uVs 12:41:44 Integrated Voltage Measurement... 12:41:53 Voltage Offset Correction: v_off_ini = 642.393 uV, v_off_fin = 646.579 uV 12:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.500 uVs 12:41:54 Integrated Voltage Measurement... 12:42:03 Voltage Offset Correction: v_off_ini = 658.976 uV, v_off_fin = 659.333 uV 12:42:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.362 uVs 12:42:05 I2X Average and RMS of Measurements VT = -43.730 +- 6.206 uVs I2X = 4.023 +- 0.571 uTm^2 12:42:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:13 Integrated Voltage Measurement... 12:42:22 Voltage Offset Correction: v_off_ini = 649.518 uV, v_off_fin = 653.143 uV 12:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.607 uVs 12:42:22 Integrated Voltage Measurement... 12:42:31 Voltage Offset Correction: v_off_ini = 647.380 uV, v_off_fin = 648.342 uV 12:42:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.113 uVs 12:42:31 Integrated Voltage Measurement... 12:42:40 Voltage Offset Correction: v_off_ini = 642.772 uV, v_off_fin = 644.324 uV 12:42:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -484.060 uVs 12:42:40 Integrated Voltage Measurement... 12:42:49 Voltage Offset Correction: v_off_ini = 654.104 uV, v_off_fin = 647.972 uV 12:42:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.763 uVs 12:42:49 Integrated Voltage Measurement... 12:42:58 Voltage Offset Correction: v_off_ini = 646.934 uV, v_off_fin = 646.968 uV 12:42:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.852 uVs 12:42:58 Integrated Voltage Measurement... 12:43:07 Voltage Offset Correction: v_off_ini = 647.510 uV, v_off_fin = 631.856 uV 12:43:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.117 uVs 12:43:09 I2Y Average and RMS of Measurements VT = -486.585 +- 3.056 uVs I2Y = -44.766 +- 0.281 uTm^2 12:43:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:24 Integrated Voltage Measurement... 12:43:33 Voltage Offset Correction: v_off_ini = 632.862 uV, v_off_fin = 636.779 uV 12:43:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -92.266 uVs 12:43:33 Integrated Voltage Measurement... 12:43:42 Voltage Offset Correction: v_off_ini = 628.077 uV, v_off_fin = 642.254 uV 12:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.324 uVs 12:43:42 Integrated Voltage Measurement... 12:43:51 Voltage Offset Correction: v_off_ini = 634.114 uV, v_off_fin = 628.319 uV 12:43:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.471 uVs 12:43:51 Integrated Voltage Measurement... 12:44:00 Voltage Offset Correction: v_off_ini = 624.464 uV, v_off_fin = 630.482 uV 12:44:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.542 uVs 12:44:00 Integrated Voltage Measurement... 12:44:09 Voltage Offset Correction: v_off_ini = 635.001 uV, v_off_fin = 634.648 uV 12:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.050 uVs 12:44:09 Integrated Voltage Measurement... 12:44:18 Voltage Offset Correction: v_off_ini = 628.767 uV, v_off_fin = 622.019 uV 12:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.618 uVs 12:44:23 I1X Average and RMS of Measurements VT = -67.212 +- 11.108 uVs I1X = 13.443 +- 2.221 uTm 12:44:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:29 Integrated Voltage Measurement... 12:44:38 Voltage Offset Correction: v_off_ini = 630.373 uV, v_off_fin = 614.262 uV 12:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.395 uVs 12:44:38 Integrated Voltage Measurement... 12:44:47 Voltage Offset Correction: v_off_ini = 642.666 uV, v_off_fin = 647.985 uV 12:44:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 238.488 uVs 12:44:47 Integrated Voltage Measurement... 12:44:56 Voltage Offset Correction: v_off_ini = 638.008 uV, v_off_fin = 624.894 uV 12:44:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.075 uVs 12:44:56 Integrated Voltage Measurement... 12:45:05 Voltage Offset Correction: v_off_ini = 651.820 uV, v_off_fin = 635.361 uV 12:45:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 243.571 uVs 12:45:06 Integrated Voltage Measurement... 12:45:14 Voltage Offset Correction: v_off_ini = 642.454 uV, v_off_fin = 636.183 uV 12:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.478 uVs 12:45:15 Integrated Voltage Measurement... 12:45:23 Voltage Offset Correction: v_off_ini = 640.538 uV, v_off_fin = 648.243 uV 12:45:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 249.675 uVs 12:45:28 I1Y Average and RMS of Measurements VT = -243.947 +- 5.017 uVs I1Y = -48.792 +- 1.004 uTm 12:45:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:45:35 Integrated Voltage Measurement... 12:45:44 Voltage Offset Correction: v_off_ini = 648.253 uV, v_off_fin = 624.620 uV 12:45:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -71.394 uVs 12:45:45 Integrated Voltage Measurement... 12:45:54 Voltage Offset Correction: v_off_ini = 645.093 uV, v_off_fin = 652.426 uV 12:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.596 uVs 12:45:54 Integrated Voltage Measurement... 12:46:03 Voltage Offset Correction: v_off_ini = 645.011 uV, v_off_fin = 630.030 uV 12:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.590 uVs 12:46:03 Integrated Voltage Measurement... 12:46:12 Voltage Offset Correction: v_off_ini = 648.858 uV, v_off_fin = 658.963 uV 12:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.295 uVs 12:46:12 Integrated Voltage Measurement... 12:46:21 Voltage Offset Correction: v_off_ini = 648.892 uV, v_off_fin = 632.285 uV 12:46:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.618 uVs 12:46:21 Integrated Voltage Measurement... 12:46:30 Voltage Offset Correction: v_off_ini = 649.996 uV, v_off_fin = 652.257 uV 12:46:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.891 uVs 12:46:32 I2X Average and RMS of Measurements VT = -46.564 +- 4.991 uVs I2X = 4.284 +- 0.459 uTm^2 12:46:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:40 Integrated Voltage Measurement... 12:46:49 Voltage Offset Correction: v_off_ini = 630.145 uV, v_off_fin = 634.776 uV 12:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.739 uVs 12:46:49 Integrated Voltage Measurement... 12:46:58 Voltage Offset Correction: v_off_ini = 647.163 uV, v_off_fin = 639.567 uV 12:46:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 470.930 uVs 12:46:58 Integrated Voltage Measurement... 12:47:07 Voltage Offset Correction: v_off_ini = 637.440 uV, v_off_fin = 644.080 uV 12:47:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.859 uVs 12:47:07 Integrated Voltage Measurement... 12:47:16 Voltage Offset Correction: v_off_ini = 643.780 uV, v_off_fin = 636.049 uV 12:47:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.208 uVs 12:47:16 Integrated Voltage Measurement... 12:47:25 Voltage Offset Correction: v_off_ini = 645.556 uV, v_off_fin = 651.547 uV 12:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.442 uVs 12:47:25 Integrated Voltage Measurement... 12:47:34 Voltage Offset Correction: v_off_ini = 646.194 uV, v_off_fin = 637.661 uV 12:47:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 461.526 uVs 12:47:37 I2Y Average and RMS of Measurements VT = -456.617 +- 1.599 uVs I2Y = -42.009 +- 0.147 uTm^2 12:47:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:52 Integrated Voltage Measurement... 12:48:01 Voltage Offset Correction: v_off_ini = 658.132 uV, v_off_fin = 654.827 uV 12:48:01 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -85.065 uVs 12:48:01 Integrated Voltage Measurement... 12:48:10 Voltage Offset Correction: v_off_ini = 654.006 uV, v_off_fin = 649.038 uV 12:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.859 uVs 12:48:10 Integrated Voltage Measurement... 12:48:19 Voltage Offset Correction: v_off_ini = 649.478 uV, v_off_fin = 643.664 uV 12:48:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.652 uVs 12:48:19 Integrated Voltage Measurement... 12:48:28 Voltage Offset Correction: v_off_ini = 660.820 uV, v_off_fin = 654.920 uV 12:48:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.198 uVs 12:48:28 Integrated Voltage Measurement... 12:48:37 Voltage Offset Correction: v_off_ini = 640.768 uV, v_off_fin = 631.311 uV 12:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.923 uVs 12:48:37 Integrated Voltage Measurement... 12:48:46 Voltage Offset Correction: v_off_ini = 655.045 uV, v_off_fin = 652.954 uV 12:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.524 uVs 12:48:50 I1X Average and RMS of Measurements VT = -74.370 +- 2.225 uVs I1X = 14.876 +- 0.446 uTm 12:48:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:57 Integrated Voltage Measurement... 12:49:06 Voltage Offset Correction: v_off_ini = 642.247 uV, v_off_fin = 639.357 uV 12:49:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.709 uVs 12:49:06 Integrated Voltage Measurement... 12:49:15 Voltage Offset Correction: v_off_ini = 658.101 uV, v_off_fin = 657.701 uV 12:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 226.060 uVs 12:49:15 Integrated Voltage Measurement... 12:49:24 Voltage Offset Correction: v_off_ini = 653.615 uV, v_off_fin = 645.496 uV 12:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.483 uVs 12:49:24 Integrated Voltage Measurement... 12:49:33 Voltage Offset Correction: v_off_ini = 645.339 uV, v_off_fin = 659.388 uV 12:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 219.868 uVs 12:49:33 Integrated Voltage Measurement... 12:49:42 Voltage Offset Correction: v_off_ini = 651.180 uV, v_off_fin = 640.441 uV 12:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.765 uVs 12:49:42 Integrated Voltage Measurement... 12:49:51 Voltage Offset Correction: v_off_ini = 645.407 uV, v_off_fin = 654.876 uV 12:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 221.988 uVs 12:49:55 I1Y Average and RMS of Measurements VT = -220.479 +- 4.589 uVs I1Y = -44.098 +- 0.918 uTm 12:50:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:03 Integrated Voltage Measurement... 12:50:12 Voltage Offset Correction: v_off_ini = 655.281 uV, v_off_fin = 646.875 uV 12:50:12 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -72.466 uVs 12:50:12 Integrated Voltage Measurement... 12:50:21 Voltage Offset Correction: v_off_ini = 657.165 uV, v_off_fin = 665.658 uV 12:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.541 uVs 12:50:21 Integrated Voltage Measurement... 12:50:30 Voltage Offset Correction: v_off_ini = 652.416 uV, v_off_fin = 649.851 uV 12:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.510 uVs 12:50:30 Integrated Voltage Measurement... 12:50:39 Voltage Offset Correction: v_off_ini = 648.159 uV, v_off_fin = 660.302 uV 12:50:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.666 uVs 12:50:39 Integrated Voltage Measurement... 12:50:48 Voltage Offset Correction: v_off_ini = 649.458 uV, v_off_fin = 655.225 uV 12:50:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -42.245 uVs 12:50:48 Integrated Voltage Measurement... 12:50:57 Voltage Offset Correction: v_off_ini = 663.810 uV, v_off_fin = 670.630 uV 12:50:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.699 uVs 12:50:59 I2X Average and RMS of Measurements VT = -56.021 +- 11.357 uVs I2X = 5.154 +- 1.045 uTm^2 12:51:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:51:07 Integrated Voltage Measurement... 12:51:16 Voltage Offset Correction: v_off_ini = 662.905 uV, v_off_fin = 661.059 uV 12:51:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -436.326 uVs 12:51:16 Integrated Voltage Measurement... 12:51:25 Voltage Offset Correction: v_off_ini = 661.557 uV, v_off_fin = 652.381 uV 12:51:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 437.228 uVs 12:51:25 Integrated Voltage Measurement... 12:51:34 Voltage Offset Correction: v_off_ini = 663.087 uV, v_off_fin = 664.018 uV 12:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -446.872 uVs 12:51:34 Integrated Voltage Measurement... 12:51:43 Voltage Offset Correction: v_off_ini = 663.641 uV, v_off_fin = 658.298 uV 12:51:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 410.776 uVs 12:51:43 Integrated Voltage Measurement... 12:51:52 Voltage Offset Correction: v_off_ini = 653.918 uV, v_off_fin = 661.811 uV 12:51:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -430.753 uVs 12:51:52 Integrated Voltage Measurement... 12:52:01 Voltage Offset Correction: v_off_ini = 675.436 uV, v_off_fin = 661.453 uV 12:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.882 uVs 12:52:04 I2Y Average and RMS of Measurements VT = -433.806 +- 3.545 uVs I2Y = -39.910 +- 0.326 uTm^2 12:52:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:19 Integrated Voltage Measurement... 12:52:28 Voltage Offset Correction: v_off_ini = 676.980 uV, v_off_fin = 674.750 uV 12:52:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -96.312 uVs 12:52:28 Integrated Voltage Measurement... 12:52:37 Voltage Offset Correction: v_off_ini = 669.532 uV, v_off_fin = 679.339 uV 12:52:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.773 uVs 12:52:37 Integrated Voltage Measurement... 12:52:46 Voltage Offset Correction: v_off_ini = 671.834 uV, v_off_fin = 673.523 uV 12:52:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.891 uVs 12:52:46 Integrated Voltage Measurement... 12:52:55 Voltage Offset Correction: v_off_ini = 693.752 uV, v_off_fin = 672.805 uV 12:52:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.838 uVs 12:52:55 Integrated Voltage Measurement... 12:53:04 Voltage Offset Correction: v_off_ini = 671.042 uV, v_off_fin = 674.851 uV 12:53:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.256 uVs 12:53:04 Integrated Voltage Measurement... 12:53:13 Voltage Offset Correction: v_off_ini = 681.501 uV, v_off_fin = 687.243 uV 12:53:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.342 uVs 12:53:17 I1X Average and RMS of Measurements VT = -80.235 +- 9.689 uVs I1X = 16.049 +- 1.939 uTm 12:53:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:24 Integrated Voltage Measurement... 12:53:33 Voltage Offset Correction: v_off_ini = 666.538 uV, v_off_fin = 651.279 uV 12:53:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -204.020 uVs 12:53:33 Integrated Voltage Measurement... 12:53:42 Voltage Offset Correction: v_off_ini = 666.045 uV, v_off_fin = 666.316 uV 12:53:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.848 uVs 12:53:42 Integrated Voltage Measurement... 12:53:51 Voltage Offset Correction: v_off_ini = 650.886 uV, v_off_fin = 644.243 uV 12:53:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.388 uVs 12:53:51 Integrated Voltage Measurement... 12:54:00 Voltage Offset Correction: v_off_ini = 665.316 uV, v_off_fin = 665.686 uV 12:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.022 uVs 12:54:00 Integrated Voltage Measurement... 12:54:09 Voltage Offset Correction: v_off_ini = 655.341 uV, v_off_fin = 639.233 uV 12:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.412 uVs 12:54:09 Integrated Voltage Measurement... 12:54:18 Voltage Offset Correction: v_off_ini = 651.357 uV, v_off_fin = 660.068 uV 12:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 216.828 uVs 12:54:22 I1Y Average and RMS of Measurements VT = -210.086 +- 3.456 uVs I1Y = -42.016 +- 0.688 uTm 12:54:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:54:30 Integrated Voltage Measurement... 12:54:39 Voltage Offset Correction: v_off_ini = 642.730 uV, v_off_fin = 636.261 uV 12:54:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -74.059 uVs 12:54:39 Integrated Voltage Measurement... 12:54:48 Voltage Offset Correction: v_off_ini = 651.159 uV, v_off_fin = 671.713 uV 12:54:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.985 uVs 12:54:48 Integrated Voltage Measurement... 12:54:57 Voltage Offset Correction: v_off_ini = 648.634 uV, v_off_fin = 644.648 uV 12:54:57 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -59.729 uVs 12:54:57 Integrated Voltage Measurement... 12:55:06 Voltage Offset Correction: v_off_ini = 655.252 uV, v_off_fin = 668.491 uV 12:55:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.264 uVs 12:55:06 Integrated Voltage Measurement... 12:55:15 Voltage Offset Correction: v_off_ini = 649.463 uV, v_off_fin = 642.794 uV 12:55:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.898 uVs 12:55:15 Integrated Voltage Measurement... 12:55:24 Voltage Offset Correction: v_off_ini = 646.698 uV, v_off_fin = 651.275 uV 12:55:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.940 uVs 12:55:27 I2X Average and RMS of Measurements VT = -61.313 +- 3.963 uVs I2X = 5.641 +- 0.364 uTm^2 12:55:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:55:34 Integrated Voltage Measurement... 12:55:43 Voltage Offset Correction: v_off_ini = 634.079 uV, v_off_fin = 629.712 uV 12:55:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.264 uVs 12:55:43 Integrated Voltage Measurement... 12:55:52 Voltage Offset Correction: v_off_ini = 628.488 uV, v_off_fin = 640.760 uV 12:55:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.887 uVs 12:55:53 Integrated Voltage Measurement... 12:56:01 Voltage Offset Correction: v_off_ini = 648.924 uV, v_off_fin = 651.723 uV 12:56:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.944 uVs 12:56:02 Integrated Voltage Measurement... 12:56:11 Voltage Offset Correction: v_off_ini = 637.443 uV, v_off_fin = 633.236 uV 12:56:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.158 uVs 12:56:11 Integrated Voltage Measurement... 12:56:20 Voltage Offset Correction: v_off_ini = 632.396 uV, v_off_fin = 618.916 uV 12:56:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.393 uVs 12:56:20 Integrated Voltage Measurement... 12:56:29 Voltage Offset Correction: v_off_ini = 626.561 uV, v_off_fin = 625.071 uV 12:56:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 402.156 uVs 12:56:31 I2Y Average and RMS of Measurements VT = -400.134 +- 2.190 uVs I2Y = -36.812 +- 0.201 uTm^2 12:56:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:56:46 Integrated Voltage Measurement... 12:56:55 Voltage Offset Correction: v_off_ini = 631.825 uV, v_off_fin = 619.476 uV 12:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.286 uVs 12:56:55 Integrated Voltage Measurement... 12:57:04 Voltage Offset Correction: v_off_ini = 630.704 uV, v_off_fin = 619.262 uV 12:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.207 uVs 12:57:04 Integrated Voltage Measurement... 12:57:13 Voltage Offset Correction: v_off_ini = 624.208 uV, v_off_fin = 620.319 uV 12:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.326 uVs 12:57:13 Integrated Voltage Measurement... 12:57:22 Voltage Offset Correction: v_off_ini = 636.037 uV, v_off_fin = 635.201 uV 12:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.953 uVs 12:57:22 Integrated Voltage Measurement... 12:57:31 Voltage Offset Correction: v_off_ini = 631.289 uV, v_off_fin = 617.920 uV 12:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.515 uVs 12:57:31 Integrated Voltage Measurement... 12:57:40 Voltage Offset Correction: v_off_ini = 627.962 uV, v_off_fin = 624.390 uV 12:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.317 uVs 12:57:44 I1X Average and RMS of Measurements VT = -92.101 +- 6.673 uVs I1X = 18.420 +- 1.335 uTm 12:57:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:57:51 Integrated Voltage Measurement... 12:58:00 Voltage Offset Correction: v_off_ini = 621.687 uV, v_off_fin = 608.239 uV 12:58:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.442 uVs 12:58:00 Integrated Voltage Measurement... 12:58:09 Voltage Offset Correction: v_off_ini = 611.238 uV, v_off_fin = 631.740 uV 12:58:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 208.539 uVs 12:58:09 Integrated Voltage Measurement... 12:58:18 Voltage Offset Correction: v_off_ini = 622.164 uV, v_off_fin = 589.781 uV 12:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.788 uVs 12:58:18 Integrated Voltage Measurement... 12:58:27 Voltage Offset Correction: v_off_ini = 610.432 uV, v_off_fin = 630.635 uV 12:58:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.280 uVs 12:58:27 Integrated Voltage Measurement... 12:58:36 Voltage Offset Correction: v_off_ini = 616.543 uV, v_off_fin = 601.718 uV 12:58:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -206.444 uVs 12:58:36 Integrated Voltage Measurement... 12:58:45 Voltage Offset Correction: v_off_ini = 608.652 uV, v_off_fin = 624.551 uV 12:58:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.422 uVs 12:58:49 I1Y Average and RMS of Measurements VT = -201.319 +- 4.690 uVs I1Y = -40.262 +- 0.936 uTm 12:58:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:58:57 Integrated Voltage Measurement... 12:59:06 Voltage Offset Correction: v_off_ini = 623.569 uV, v_off_fin = 603.271 uV 12:59:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -73.208 uVs 12:59:06 Integrated Voltage Measurement... 12:59:15 Voltage Offset Correction: v_off_ini = 634.975 uV, v_off_fin = 644.823 uV 12:59:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.732 uVs 12:59:15 Integrated Voltage Measurement... 12:59:24 Voltage Offset Correction: v_off_ini = 624.259 uV, v_off_fin = 607.131 uV 12:59:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.936 uVs 12:59:24 Integrated Voltage Measurement... 12:59:33 Voltage Offset Correction: v_off_ini = 615.488 uV, v_off_fin = 620.608 uV 12:59:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.108 uVs 12:59:33 Integrated Voltage Measurement... 12:59:42 Voltage Offset Correction: v_off_ini = 620.649 uV, v_off_fin = 610.870 uV 12:59:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -88.491 uVs 12:59:42 Integrated Voltage Measurement... 12:59:51 Voltage Offset Correction: v_off_ini = 616.445 uV, v_off_fin = 631.644 uV 12:59:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.367 uVs 12:59:54 I2X Average and RMS of Measurements VT = -81.807 +- 2.215 uVs I2X = 7.527 +- 0.204 uTm^2 12:59:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:01 Integrated Voltage Measurement... 13:00:10 Voltage Offset Correction: v_off_ini = 614.779 uV, v_off_fin = 615.983 uV 13:00:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.202 uVs 13:00:11 Integrated Voltage Measurement... 13:00:19 Voltage Offset Correction: v_off_ini = 617.836 uV, v_off_fin = 621.820 uV 13:00:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.585 uVs 13:00:20 Integrated Voltage Measurement... 13:00:29 Voltage Offset Correction: v_off_ini = 619.817 uV, v_off_fin = 627.700 uV 13:00:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.380 uVs 13:00:29 Integrated Voltage Measurement... 13:00:38 Voltage Offset Correction: v_off_ini = 614.185 uV, v_off_fin = 619.795 uV 13:00:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 384.158 uVs 13:00:38 Integrated Voltage Measurement... 13:00:47 Voltage Offset Correction: v_off_ini = 625.377 uV, v_off_fin = 626.759 uV 13:00:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.643 uVs 13:00:47 Integrated Voltage Measurement... 13:00:56 Voltage Offset Correction: v_off_ini = 640.834 uV, v_off_fin = 624.934 uV 13:00:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.282 uVs 13:00:58 I2Y Average and RMS of Measurements VT = -381.208 +- 8.336 uVs I2Y = -35.071 +- 0.767 uTm^2 13:01:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:13 Integrated Voltage Measurement... 13:01:22 Voltage Offset Correction: v_off_ini = 638.010 uV, v_off_fin = 616.842 uV 13:01:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.549 uVs 13:01:22 Integrated Voltage Measurement... 13:01:31 Voltage Offset Correction: v_off_ini = 631.350 uV, v_off_fin = 632.584 uV 13:01:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.186 uVs 13:01:31 Integrated Voltage Measurement... 13:01:40 Voltage Offset Correction: v_off_ini = 629.935 uV, v_off_fin = 623.446 uV 13:01:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.329 uVs 13:01:40 Integrated Voltage Measurement... 13:01:49 Voltage Offset Correction: v_off_ini = 621.535 uV, v_off_fin = 618.886 uV 13:01:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.554 uVs 13:01:49 Integrated Voltage Measurement... 13:01:58 Voltage Offset Correction: v_off_ini = 608.340 uV, v_off_fin = 615.854 uV 13:01:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.218 uVs 13:01:58 Integrated Voltage Measurement... 13:02:07 Voltage Offset Correction: v_off_ini = 619.420 uV, v_off_fin = 607.340 uV 13:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.311 uVs 13:02:11 I1X Average and RMS of Measurements VT = -101.191 +- 9.209 uVs I1X = 20.240 +- 1.843 uTm 13:02:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:02:18 Integrated Voltage Measurement... 13:02:27 Voltage Offset Correction: v_off_ini = 615.204 uV, v_off_fin = 606.047 uV 13:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.045 uVs 13:02:27 Integrated Voltage Measurement... 13:02:36 Voltage Offset Correction: v_off_ini = 614.632 uV, v_off_fin = 615.299 uV 13:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.118 uVs 13:02:36 Integrated Voltage Measurement... 13:02:45 Voltage Offset Correction: v_off_ini = 594.672 uV, v_off_fin = 591.947 uV 13:02:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.854 uVs 13:02:45 Integrated Voltage Measurement... 13:02:54 Voltage Offset Correction: v_off_ini = 610.608 uV, v_off_fin = 616.177 uV 13:02:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.741 uVs 13:02:54 Integrated Voltage Measurement... 13:03:03 Voltage Offset Correction: v_off_ini = 587.002 uV, v_off_fin = 591.283 uV 13:03:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.277 uVs 13:03:03 Integrated Voltage Measurement... 13:03:12 Voltage Offset Correction: v_off_ini = 601.113 uV, v_off_fin = 615.395 uV 13:03:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.167 uVs 13:03:16 I1Y Average and RMS of Measurements VT = -183.700 +- 8.289 uVs I1Y = -36.738 +- 1.657 uTm 13:03:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:24 Integrated Voltage Measurement... 13:03:33 Voltage Offset Correction: v_off_ini = 597.514 uV, v_off_fin = 582.725 uV 13:03:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -85.080 uVs 13:03:33 Integrated Voltage Measurement... 13:03:42 Voltage Offset Correction: v_off_ini = 593.745 uV, v_off_fin = 614.456 uV 13:03:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.470 uVs 13:03:42 Integrated Voltage Measurement... 13:03:51 Voltage Offset Correction: v_off_ini = 600.096 uV, v_off_fin = 587.619 uV 13:03:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.833 uVs 13:03:51 Integrated Voltage Measurement... 13:04:00 Voltage Offset Correction: v_off_ini = 611.768 uV, v_off_fin = 619.305 uV 13:04:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.205 uVs 13:04:00 Integrated Voltage Measurement... 13:04:09 Voltage Offset Correction: v_off_ini = 600.570 uV, v_off_fin = 589.120 uV 13:04:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.629 uVs 13:04:09 Integrated Voltage Measurement... 13:04:18 Voltage Offset Correction: v_off_ini = 593.554 uV, v_off_fin = 602.496 uV 13:04:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.247 uVs 13:04:21 I2X Average and RMS of Measurements VT = -91.244 +- 0.941 uVs I2X = 8.394 +- 0.087 uTm^2 13:04:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:04:28 Integrated Voltage Measurement... 13:04:37 Voltage Offset Correction: v_off_ini = 606.235 uV, v_off_fin = 599.608 uV 13:04:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.022 uVs 13:04:37 Integrated Voltage Measurement... 13:04:46 Voltage Offset Correction: v_off_ini = 588.313 uV, v_off_fin = 607.363 uV 13:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.407 uVs 13:04:47 Integrated Voltage Measurement... 13:04:55 Voltage Offset Correction: v_off_ini = 587.240 uV, v_off_fin = 584.775 uV 13:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.525 uVs 13:04:56 Integrated Voltage Measurement... 13:05:05 Voltage Offset Correction: v_off_ini = 601.368 uV, v_off_fin = 599.272 uV 13:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.157 uVs 13:05:05 Integrated Voltage Measurement... 13:05:14 Voltage Offset Correction: v_off_ini = 609.118 uV, v_off_fin = 601.982 uV 13:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.102 uVs 13:05:14 Integrated Voltage Measurement... 13:05:23 Voltage Offset Correction: v_off_ini = 599.800 uV, v_off_fin = 604.789 uV 13:05:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.052 uVs 13:05:25 I2Y Average and RMS of Measurements VT = -353.377 +- 6.187 uVs I2Y = -32.511 +- 0.569 uTm^2 13:05:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:40 Integrated Voltage Measurement... 13:05:49 Voltage Offset Correction: v_off_ini = 586.464 uV, v_off_fin = 594.894 uV 13:05:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.834 uVs 13:05:49 Integrated Voltage Measurement... 13:05:58 Voltage Offset Correction: v_off_ini = 591.003 uV, v_off_fin = 600.882 uV 13:05:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.698 uVs 13:05:58 Integrated Voltage Measurement... 13:06:07 Voltage Offset Correction: v_off_ini = 601.196 uV, v_off_fin = 595.058 uV 13:06:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.866 uVs 13:06:07 Integrated Voltage Measurement... 13:06:16 Voltage Offset Correction: v_off_ini = 601.021 uV, v_off_fin = 602.154 uV 13:06:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.305 uVs 13:06:16 Integrated Voltage Measurement... 13:06:25 Voltage Offset Correction: v_off_ini = 602.437 uV, v_off_fin = 604.977 uV 13:06:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.331 uVs 13:06:25 Integrated Voltage Measurement... 13:06:34 Voltage Offset Correction: v_off_ini = 597.937 uV, v_off_fin = 594.890 uV 13:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.552 uVs 13:06:38 I1X Average and RMS of Measurements VT = -105.098 +- 2.679 uVs I1X = 21.021 +- 0.536 uTm 13:06:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:45 Integrated Voltage Measurement... 13:06:54 Voltage Offset Correction: v_off_ini = 579.540 uV, v_off_fin = 567.151 uV 13:06:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.350 uVs 13:06:54 Integrated Voltage Measurement... 13:07:03 Voltage Offset Correction: v_off_ini = 590.486 uV, v_off_fin = 607.141 uV 13:07:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 173.616 uVs 13:07:03 Integrated Voltage Measurement... 13:07:12 Voltage Offset Correction: v_off_ini = 599.707 uV, v_off_fin = 578.418 uV 13:07:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.659 uVs 13:07:12 Integrated Voltage Measurement... 13:07:21 Voltage Offset Correction: v_off_ini = 576.703 uV, v_off_fin = 600.548 uV 13:07:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.950 uVs 13:07:21 Integrated Voltage Measurement... 13:07:30 Voltage Offset Correction: v_off_ini = 576.482 uV, v_off_fin = 579.018 uV 13:07:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.095 uVs 13:07:30 Integrated Voltage Measurement... 13:07:39 Voltage Offset Correction: v_off_ini = 600.081 uV, v_off_fin = 599.451 uV 13:07:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.051 uVs 13:07:43 I1Y Average and RMS of Measurements VT = -176.787 +- 3.124 uVs I1Y = -35.356 +- 0.624 uTm 13:07:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:07:51 Integrated Voltage Measurement... 13:08:00 Voltage Offset Correction: v_off_ini = 600.130 uV, v_off_fin = 586.779 uV 13:08:00 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -113.584 uVs 13:08:00 Integrated Voltage Measurement... 13:08:09 Voltage Offset Correction: v_off_ini = 581.407 uV, v_off_fin = 591.949 uV 13:08:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.103 uVs 13:08:09 Integrated Voltage Measurement... 13:08:18 Voltage Offset Correction: v_off_ini = 584.538 uV, v_off_fin = 575.997 uV 13:08:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.076 uVs 13:08:18 Integrated Voltage Measurement... 13:08:27 Voltage Offset Correction: v_off_ini = 583.856 uV, v_off_fin = 595.227 uV 13:08:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.871 uVs 13:08:27 Integrated Voltage Measurement... 13:08:36 Voltage Offset Correction: v_off_ini = 585.817 uV, v_off_fin = 562.876 uV 13:08:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.265 uVs 13:08:36 Integrated Voltage Measurement... 13:08:45 Voltage Offset Correction: v_off_ini = 568.953 uV, v_off_fin = 582.349 uV 13:08:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.702 uVs 13:08:48 I2X Average and RMS of Measurements VT = -96.933 +- 9.823 uVs I2X = 8.918 +- 0.904 uTm^2 13:08:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:56 Integrated Voltage Measurement... 13:09:04 Voltage Offset Correction: v_off_ini = 570.957 uV, v_off_fin = 581.248 uV 13:09:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.495 uVs 13:09:05 Integrated Voltage Measurement... 13:09:14 Voltage Offset Correction: v_off_ini = 572.886 uV, v_off_fin = 575.109 uV 13:09:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.440 uVs 13:09:14 Integrated Voltage Measurement... 13:09:23 Voltage Offset Correction: v_off_ini = 560.526 uV, v_off_fin = 578.226 uV 13:09:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.728 uVs 13:09:23 Integrated Voltage Measurement... 13:09:32 Voltage Offset Correction: v_off_ini = 580.388 uV, v_off_fin = 567.663 uV 13:09:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.742 uVs 13:09:32 Integrated Voltage Measurement... 13:09:41 Voltage Offset Correction: v_off_ini = 562.254 uV, v_off_fin = 565.105 uV 13:09:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.341 uVs 13:09:41 Integrated Voltage Measurement... 13:09:50 Voltage Offset Correction: v_off_ini = 567.354 uV, v_off_fin = 581.219 uV 13:09:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.666 uVs 13:09:52 I2Y Average and RMS of Measurements VT = -337.236 +- 4.179 uVs I2Y = -31.026 +- 0.384 uTm^2 13:10:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:10:07 Integrated Voltage Measurement... 13:10:16 Voltage Offset Correction: v_off_ini = 570.101 uV, v_off_fin = 557.725 uV 13:10:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -107.764 uVs 13:10:16 Integrated Voltage Measurement... 13:10:25 Voltage Offset Correction: v_off_ini = 570.228 uV, v_off_fin = 577.229 uV 13:10:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.779 uVs 13:10:25 Integrated Voltage Measurement... 13:10:34 Voltage Offset Correction: v_off_ini = 566.112 uV, v_off_fin = 573.397 uV 13:10:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.760 uVs 13:10:34 Integrated Voltage Measurement... 13:10:43 Voltage Offset Correction: v_off_ini = 576.042 uV, v_off_fin = 572.450 uV 13:10:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.035 uVs 13:10:43 Integrated Voltage Measurement... 13:10:52 Voltage Offset Correction: v_off_ini = 569.905 uV, v_off_fin = 557.210 uV 13:10:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.275 uVs 13:10:52 Integrated Voltage Measurement... 13:11:01 Voltage Offset Correction: v_off_ini = 567.003 uV, v_off_fin = 572.057 uV 13:11:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.667 uVs 13:11:05 I1X Average and RMS of Measurements VT = -109.380 +- 4.992 uVs I1X = 21.877 +- 0.999 uTm 13:11:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:12 Integrated Voltage Measurement... 13:11:21 Voltage Offset Correction: v_off_ini = 579.695 uV, v_off_fin = 566.408 uV 13:11:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.049 uVs 13:11:21 Integrated Voltage Measurement... 13:11:30 Voltage Offset Correction: v_off_ini = 570.413 uV, v_off_fin = 589.372 uV 13:11:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.305 uVs 13:11:30 Integrated Voltage Measurement... 13:11:39 Voltage Offset Correction: v_off_ini = 576.125 uV, v_off_fin = 563.908 uV 13:11:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.441 uVs 13:11:39 Integrated Voltage Measurement... 13:11:48 Voltage Offset Correction: v_off_ini = 579.403 uV, v_off_fin = 588.283 uV 13:11:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.079 uVs 13:11:48 Integrated Voltage Measurement... 13:11:57 Voltage Offset Correction: v_off_ini = 584.760 uV, v_off_fin = 573.074 uV 13:11:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.643 uVs 13:11:57 Integrated Voltage Measurement... 13:12:06 Voltage Offset Correction: v_off_ini = 582.713 uV, v_off_fin = 594.691 uV 13:12:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 142.605 uVs 13:12:10 I1Y Average and RMS of Measurements VT = -167.187 +- 6.586 uVs I1Y = -33.437 +- 1.316 uTm 13:12:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:18 Integrated Voltage Measurement... 13:12:27 Voltage Offset Correction: v_off_ini = 577.328 uV, v_off_fin = 588.491 uV 13:12:27 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -93.057 uVs 13:12:27 Integrated Voltage Measurement... 13:12:36 Voltage Offset Correction: v_off_ini = 577.843 uV, v_off_fin = 599.623 uV 13:12:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.235 uVs 13:12:36 Integrated Voltage Measurement... 13:12:45 Voltage Offset Correction: v_off_ini = 586.115 uV, v_off_fin = 576.371 uV 13:12:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.683 uVs 13:12:45 Integrated Voltage Measurement... 13:12:54 Voltage Offset Correction: v_off_ini = 590.224 uV, v_off_fin = 589.230 uV 13:12:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.633 uVs 13:12:54 Integrated Voltage Measurement... 13:13:03 Voltage Offset Correction: v_off_ini = 584.307 uV, v_off_fin = 581.279 uV 13:13:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.247 uVs 13:13:03 Integrated Voltage Measurement... 13:13:12 Voltage Offset Correction: v_off_ini = 589.373 uV, v_off_fin = 601.546 uV 13:13:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.471 uVs 13:13:15 I2X Average and RMS of Measurements VT = -99.888 +- 5.814 uVs I2X = 9.189 +- 0.535 uTm^2 13:13:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:23 Integrated Voltage Measurement... 13:13:32 Voltage Offset Correction: v_off_ini = 585.804 uV, v_off_fin = 580.856 uV 13:13:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.918 uVs 13:13:32 Integrated Voltage Measurement... 13:13:41 Voltage Offset Correction: v_off_ini = 582.392 uV, v_off_fin = 581.135 uV 13:13:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.418 uVs 13:13:41 Integrated Voltage Measurement... 13:13:50 Voltage Offset Correction: v_off_ini = 579.553 uV, v_off_fin = 582.613 uV 13:13:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.188 uVs 13:13:50 Integrated Voltage Measurement... 13:13:59 Voltage Offset Correction: v_off_ini = 587.026 uV, v_off_fin = 582.959 uV 13:13:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.546 uVs 13:13:59 Integrated Voltage Measurement... 13:14:08 Voltage Offset Correction: v_off_ini = 583.796 uV, v_off_fin = 582.772 uV 13:14:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.956 uVs 13:14:08 Integrated Voltage Measurement... 13:14:17 Voltage Offset Correction: v_off_ini = 573.685 uV, v_off_fin = 575.665 uV 13:14:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.430 uVs 13:14:19 I2Y Average and RMS of Measurements VT = -320.576 +- 7.760 uVs I2Y = -29.493 +- 0.714 uTm^2 13:14:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:34 Integrated Voltage Measurement... 13:14:43 Voltage Offset Correction: v_off_ini = 591.673 uV, v_off_fin = 575.911 uV 13:14:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.989 uVs 13:14:43 Integrated Voltage Measurement... 13:14:52 Voltage Offset Correction: v_off_ini = 592.486 uV, v_off_fin = 590.689 uV 13:14:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.790 uVs 13:14:52 Integrated Voltage Measurement... 13:15:01 Voltage Offset Correction: v_off_ini = 584.282 uV, v_off_fin = 586.604 uV 13:15:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.162 uVs 13:15:01 Integrated Voltage Measurement... 13:15:10 Voltage Offset Correction: v_off_ini = 579.329 uV, v_off_fin = 572.215 uV 13:15:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.521 uVs 13:15:10 Integrated Voltage Measurement... 13:15:19 Voltage Offset Correction: v_off_ini = 576.197 uV, v_off_fin = 575.247 uV 13:15:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.623 uVs 13:15:19 Integrated Voltage Measurement... 13:15:28 Voltage Offset Correction: v_off_ini = 589.077 uV, v_off_fin = 577.154 uV 13:15:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.122 uVs 13:15:32 I1X Average and RMS of Measurements VT = -110.034 +- 8.246 uVs I1X = 22.008 +- 1.650 uTm 13:15:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:39 Integrated Voltage Measurement... 13:15:48 Voltage Offset Correction: v_off_ini = 578.172 uV, v_off_fin = 560.347 uV 13:15:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -155.898 uVs 13:15:48 Integrated Voltage Measurement... 13:15:57 Voltage Offset Correction: v_off_ini = 577.600 uV, v_off_fin = 559.452 uV 13:15:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 151.542 uVs 13:15:57 Integrated Voltage Measurement... 13:16:06 Voltage Offset Correction: v_off_ini = 570.350 uV, v_off_fin = 556.255 uV 13:16:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.844 uVs 13:16:06 Integrated Voltage Measurement... 13:16:15 Voltage Offset Correction: v_off_ini = 575.704 uV, v_off_fin = 576.712 uV 13:16:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.482 uVs 13:16:15 Integrated Voltage Measurement... 13:16:24 Voltage Offset Correction: v_off_ini = 571.502 uV, v_off_fin = 556.237 uV 13:16:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -155.348 uVs 13:16:24 Integrated Voltage Measurement... 13:16:33 Voltage Offset Correction: v_off_ini = 582.480 uV, v_off_fin = 573.449 uV 13:16:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.356 uVs 13:16:37 I1Y Average and RMS of Measurements VT = -161.078 +- 6.823 uVs I1Y = -32.216 +- 1.365 uTm 13:16:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:45 Integrated Voltage Measurement... 13:16:54 Voltage Offset Correction: v_off_ini = 554.445 uV, v_off_fin = 546.065 uV 13:16:54 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.031 uVs 13:16:54 Integrated Voltage Measurement... 13:17:03 Voltage Offset Correction: v_off_ini = 555.887 uV, v_off_fin = 566.598 uV 13:17:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.552 uVs 13:17:03 Integrated Voltage Measurement... 13:17:12 Voltage Offset Correction: v_off_ini = 563.432 uV, v_off_fin = 548.750 uV 13:17:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -117.220 uVs 13:17:12 Integrated Voltage Measurement... 13:17:21 Voltage Offset Correction: v_off_ini = 551.298 uV, v_off_fin = 561.359 uV 13:17:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 109.077 uVs 13:17:21 Integrated Voltage Measurement... 13:17:30 Voltage Offset Correction: v_off_ini = 563.829 uV, v_off_fin = 546.300 uV 13:17:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.674 uVs 13:17:30 Integrated Voltage Measurement... 13:17:39 Voltage Offset Correction: v_off_ini = 549.327 uV, v_off_fin = 561.890 uV 13:17:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.858 uVs 13:17:42 I2X Average and RMS of Measurements VT = -110.902 +- 3.279 uVs I2X = 10.203 +- 0.302 uTm^2 13:17:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:50 Integrated Voltage Measurement... 13:17:59 Voltage Offset Correction: v_off_ini = 568.532 uV, v_off_fin = 558.232 uV 13:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.501 uVs 13:17:59 Integrated Voltage Measurement... 13:18:08 Voltage Offset Correction: v_off_ini = 568.692 uV, v_off_fin = 544.041 uV 13:18:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.466 uVs 13:18:08 Integrated Voltage Measurement... 13:18:17 Voltage Offset Correction: v_off_ini = 546.985 uV, v_off_fin = 553.143 uV 13:18:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.680 uVs 13:18:17 Integrated Voltage Measurement... 13:18:26 Voltage Offset Correction: v_off_ini = 557.596 uV, v_off_fin = 544.353 uV 13:18:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.822 uVs 13:18:26 Integrated Voltage Measurement... 13:18:35 Voltage Offset Correction: v_off_ini = 554.318 uV, v_off_fin = 547.342 uV 13:18:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.833 uVs 13:18:35 Integrated Voltage Measurement... 13:18:44 Voltage Offset Correction: v_off_ini = 557.080 uV, v_off_fin = 553.002 uV 13:18:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.230 uVs 13:18:46 I2Y Average and RMS of Measurements VT = -310.422 +- 3.785 uVs I2Y = -28.559 +- 0.348 uTm^2 13:18:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:01 Integrated Voltage Measurement... 13:19:10 Voltage Offset Correction: v_off_ini = 551.216 uV, v_off_fin = 552.916 uV 13:19:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.051 uVs 13:19:10 Integrated Voltage Measurement... 13:19:19 Voltage Offset Correction: v_off_ini = 551.358 uV, v_off_fin = 541.730 uV 13:19:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.118 uVs 13:19:19 Integrated Voltage Measurement... 13:19:28 Voltage Offset Correction: v_off_ini = 545.373 uV, v_off_fin = 548.918 uV 13:19:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.508 uVs 13:19:28 Integrated Voltage Measurement... 13:19:37 Voltage Offset Correction: v_off_ini = 543.171 uV, v_off_fin = 539.858 uV 13:19:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.503 uVs 13:19:37 Integrated Voltage Measurement... 13:19:46 Voltage Offset Correction: v_off_ini = 543.186 uV, v_off_fin = 547.528 uV 13:19:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.094 uVs 13:19:46 Integrated Voltage Measurement... 13:19:55 Voltage Offset Correction: v_off_ini = 538.591 uV, v_off_fin = 549.299 uV 13:19:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.307 uVs 13:19:59 I1X Average and RMS of Measurements VT = -118.430 +- 9.355 uVs I1X = 23.687 +- 1.870 uTm 13:20:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:20:06 Integrated Voltage Measurement... 13:20:15 Voltage Offset Correction: v_off_ini = 547.247 uV, v_off_fin = 534.002 uV 13:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -153.441 uVs 13:20:15 Integrated Voltage Measurement... 13:20:24 Voltage Offset Correction: v_off_ini = 551.245 uV, v_off_fin = 569.135 uV 13:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.217 uVs 13:20:24 Integrated Voltage Measurement... 13:20:33 Voltage Offset Correction: v_off_ini = 545.944 uV, v_off_fin = 528.655 uV 13:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -138.660 uVs 13:20:33 Integrated Voltage Measurement... 13:20:42 Voltage Offset Correction: v_off_ini = 550.837 uV, v_off_fin = 553.211 uV 13:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 147.658 uVs 13:20:42 Integrated Voltage Measurement... 13:20:51 Voltage Offset Correction: v_off_ini = 548.068 uV, v_off_fin = 548.756 uV 13:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.497 uVs 13:20:51 Integrated Voltage Measurement... 13:21:00 Voltage Offset Correction: v_off_ini = 562.225 uV, v_off_fin = 562.302 uV 13:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 148.581 uVs 13:21:04 I1Y Average and RMS of Measurements VT = -151.009 +- 5.703 uVs I1Y = -30.201 +- 1.140 uTm 13:21:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:12 Integrated Voltage Measurement... 13:21:21 Voltage Offset Correction: v_off_ini = 550.820 uV, v_off_fin = 549.024 uV 13:21:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -99.479 uVs 13:21:21 Integrated Voltage Measurement... 13:21:30 Voltage Offset Correction: v_off_ini = 551.178 uV, v_off_fin = 556.081 uV 13:21:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.439 uVs 13:21:30 Integrated Voltage Measurement... 13:21:39 Voltage Offset Correction: v_off_ini = 554.722 uV, v_off_fin = 541.431 uV 13:21:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.607 uVs 13:21:39 Integrated Voltage Measurement... 13:21:48 Voltage Offset Correction: v_off_ini = 557.663 uV, v_off_fin = 577.517 uV 13:21:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.002 uVs 13:21:48 Integrated Voltage Measurement... 13:21:57 Voltage Offset Correction: v_off_ini = 559.232 uV, v_off_fin = 555.875 uV 13:21:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.952 uVs 13:21:57 Integrated Voltage Measurement... 13:22:06 Voltage Offset Correction: v_off_ini = 566.739 uV, v_off_fin = 566.103 uV 13:22:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.405 uVs 13:22:09 I2X Average and RMS of Measurements VT = -105.647 +- 3.994 uVs I2X = 9.720 +- 0.367 uTm^2 13:22:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:22:16 Integrated Voltage Measurement... 13:22:25 Voltage Offset Correction: v_off_ini = 547.796 uV, v_off_fin = 560.965 uV 13:22:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.996 uVs 13:22:26 Integrated Voltage Measurement... 13:22:34 Voltage Offset Correction: v_off_ini = 577.032 uV, v_off_fin = 573.657 uV 13:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.284 uVs 13:22:35 Integrated Voltage Measurement... 13:22:44 Voltage Offset Correction: v_off_ini = 564.416 uV, v_off_fin = 562.293 uV 13:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.386 uVs 13:22:44 Integrated Voltage Measurement... 13:22:53 Voltage Offset Correction: v_off_ini = 569.943 uV, v_off_fin = 568.462 uV 13:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.351 uVs 13:22:53 Integrated Voltage Measurement... 13:23:02 Voltage Offset Correction: v_off_ini = 550.180 uV, v_off_fin = 558.264 uV 13:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.631 uVs 13:23:02 Integrated Voltage Measurement... 13:23:11 Voltage Offset Correction: v_off_ini = 548.455 uV, v_off_fin = 561.362 uV 13:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.409 uVs 13:23:13 I2Y Average and RMS of Measurements VT = -297.343 +- 6.748 uVs I2Y = -27.356 +- 0.621 uTm^2 13:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:23:28 Integrated Voltage Measurement... 13:23:37 Voltage Offset Correction: v_off_ini = 562.019 uV, v_off_fin = 553.860 uV 13:23:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -122.778 uVs 13:23:37 Integrated Voltage Measurement... 13:23:46 Voltage Offset Correction: v_off_ini = 559.548 uV, v_off_fin = 557.828 uV 13:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.488 uVs 13:23:46 Integrated Voltage Measurement... 13:23:55 Voltage Offset Correction: v_off_ini = 572.113 uV, v_off_fin = 558.356 uV 13:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.228 uVs 13:23:55 Integrated Voltage Measurement... 13:24:04 Voltage Offset Correction: v_off_ini = 572.151 uV, v_off_fin = 553.736 uV 13:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.277 uVs 13:24:04 Integrated Voltage Measurement... 13:24:13 Voltage Offset Correction: v_off_ini = 554.944 uV, v_off_fin = 543.882 uV 13:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.984 uVs 13:24:13 Integrated Voltage Measurement... 13:24:22 Voltage Offset Correction: v_off_ini = 555.652 uV, v_off_fin = 536.609 uV 13:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 105.768 uVs 13:24:26 I1X Average and RMS of Measurements VT = -120.087 +- 2.636 uVs I1X = 24.018 +- 0.528 uTm 13:24:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:33 Integrated Voltage Measurement... 13:24:42 Voltage Offset Correction: v_off_ini = 552.367 uV, v_off_fin = 534.601 uV 13:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -138.270 uVs 13:24:42 Integrated Voltage Measurement... 13:24:51 Voltage Offset Correction: v_off_ini = 550.399 uV, v_off_fin = 550.951 uV 13:24:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.376 uVs 13:24:51 Integrated Voltage Measurement... 13:25:00 Voltage Offset Correction: v_off_ini = 540.559 uV, v_off_fin = 534.404 uV 13:25:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -149.604 uVs 13:25:00 Integrated Voltage Measurement... 13:25:09 Voltage Offset Correction: v_off_ini = 549.929 uV, v_off_fin = 554.074 uV 13:25:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.530 uVs 13:25:09 Integrated Voltage Measurement... 13:25:18 Voltage Offset Correction: v_off_ini = 553.725 uV, v_off_fin = 541.341 uV 13:25:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -147.722 uVs 13:25:18 Integrated Voltage Measurement... 13:25:27 Voltage Offset Correction: v_off_ini = 549.435 uV, v_off_fin = 559.497 uV 13:25:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.559 uVs 13:25:31 I1Y Average and RMS of Measurements VT = -147.010 +- 2.664 uVs I1Y = -29.402 +- 0.534 uTm 13:25:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:39 Integrated Voltage Measurement... 13:25:48 Voltage Offset Correction: v_off_ini = 547.481 uV, v_off_fin = 525.089 uV 13:25:48 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -114.680 uVs 13:25:48 Integrated Voltage Measurement... 13:25:57 Voltage Offset Correction: v_off_ini = 542.990 uV, v_off_fin = 555.424 uV 13:25:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.477 uVs 13:25:57 Integrated Voltage Measurement... 13:26:06 Voltage Offset Correction: v_off_ini = 542.222 uV, v_off_fin = 526.219 uV 13:26:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.411 uVs 13:26:06 Integrated Voltage Measurement... 13:26:15 Voltage Offset Correction: v_off_ini = 540.339 uV, v_off_fin = 533.664 uV 13:26:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.741 uVs 13:26:15 Integrated Voltage Measurement... 13:26:24 Voltage Offset Correction: v_off_ini = 551.662 uV, v_off_fin = 544.257 uV 13:26:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.249 uVs 13:26:24 Integrated Voltage Measurement... 13:26:33 Voltage Offset Correction: v_off_ini = 536.460 uV, v_off_fin = 547.459 uV 13:26:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.634 uVs 13:26:36 I2X Average and RMS of Measurements VT = -122.199 +- 5.829 uVs I2X = 11.242 +- 0.537 uTm^2 13:26:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:26:43 Integrated Voltage Measurement... 13:26:52 Voltage Offset Correction: v_off_ini = 543.445 uV, v_off_fin = 542.206 uV 13:26:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.179 uVs 13:26:52 Integrated Voltage Measurement... 13:27:01 Voltage Offset Correction: v_off_ini = 555.276 uV, v_off_fin = 558.097 uV 13:27:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.101 uVs 13:27:02 Integrated Voltage Measurement... 13:27:10 Voltage Offset Correction: v_off_ini = 564.233 uV, v_off_fin = 555.580 uV 13:27:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -290.288 uVs 13:27:11 Integrated Voltage Measurement... 13:27:19 Voltage Offset Correction: v_off_ini = 551.893 uV, v_off_fin = 557.457 uV 13:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.007 uVs 13:27:20 Integrated Voltage Measurement... 13:27:29 Voltage Offset Correction: v_off_ini = 550.460 uV, v_off_fin = 556.250 uV 13:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.787 uVs 13:27:29 Integrated Voltage Measurement... 13:27:38 Voltage Offset Correction: v_off_ini = 561.902 uV, v_off_fin = 558.937 uV 13:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.342 uVs 13:27:40 I2Y Average and RMS of Measurements VT = -294.451 +- 3.148 uVs I2Y = -27.089 +- 0.290 uTm^2 13:27:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:56 Integrated Voltage Measurement... 13:28:05 Voltage Offset Correction: v_off_ini = 562.498 uV, v_off_fin = 551.534 uV 13:28:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -142.835 uVs 13:28:05 Integrated Voltage Measurement... 13:28:14 Voltage Offset Correction: v_off_ini = 559.381 uV, v_off_fin = 552.200 uV 13:28:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.432 uVs 13:28:14 Integrated Voltage Measurement... 13:28:23 Voltage Offset Correction: v_off_ini = 553.526 uV, v_off_fin = 564.949 uV 13:28:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.864 uVs 13:28:23 Integrated Voltage Measurement... 13:28:32 Voltage Offset Correction: v_off_ini = 566.873 uV, v_off_fin = 564.406 uV 13:28:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.333 uVs 13:28:32 Integrated Voltage Measurement... 13:28:41 Voltage Offset Correction: v_off_ini = 560.919 uV, v_off_fin = 558.924 uV 13:28:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.439 uVs 13:28:41 Integrated Voltage Measurement... 13:28:50 Voltage Offset Correction: v_off_ini = 560.308 uV, v_off_fin = 565.945 uV 13:28:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.807 uVs 13:28:54 I1X Average and RMS of Measurements VT = -130.285 +- 7.689 uVs I1X = 26.058 +- 1.537 uTm 13:28:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:29:01 Integrated Voltage Measurement... 13:29:10 Voltage Offset Correction: v_off_ini = 553.152 uV, v_off_fin = 538.405 uV 13:29:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -137.511 uVs 13:29:10 Integrated Voltage Measurement... 13:29:19 Voltage Offset Correction: v_off_ini = 564.238 uV, v_off_fin = 572.944 uV 13:29:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.777 uVs 13:29:19 Integrated Voltage Measurement... 13:29:28 Voltage Offset Correction: v_off_ini = 548.042 uV, v_off_fin = 542.071 uV 13:29:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -135.692 uVs 13:29:28 Integrated Voltage Measurement... 13:29:37 Voltage Offset Correction: v_off_ini = 555.855 uV, v_off_fin = 556.353 uV 13:29:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 143.125 uVs 13:29:37 Integrated Voltage Measurement... 13:29:46 Voltage Offset Correction: v_off_ini = 551.981 uV, v_off_fin = 549.334 uV 13:29:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -140.133 uVs 13:29:46 Integrated Voltage Measurement... 13:29:55 Voltage Offset Correction: v_off_ini = 570.327 uV, v_off_fin = 570.027 uV 13:29:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.957 uVs 13:29:59 I1Y Average and RMS of Measurements VT = -138.199 +- 1.211 uVs I1Y = -27.638 +- 0.242 uTm 13:30:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:30:07 Integrated Voltage Measurement... 13:30:16 Voltage Offset Correction: v_off_ini = 562.051 uV, v_off_fin = 553.802 uV 13:30:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.055 uVs 13:30:16 Integrated Voltage Measurement... 13:30:25 Voltage Offset Correction: v_off_ini = 546.865 uV, v_off_fin = 544.897 uV 13:30:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.048 uVs 13:30:25 Integrated Voltage Measurement... 13:30:34 Voltage Offset Correction: v_off_ini = 539.153 uV, v_off_fin = 549.248 uV 13:30:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -135.210 uVs 13:30:34 Integrated Voltage Measurement... 13:30:43 Voltage Offset Correction: v_off_ini = 572.598 uV, v_off_fin = 573.232 uV 13:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.668 uVs 13:30:43 Integrated Voltage Measurement... 13:30:52 Voltage Offset Correction: v_off_ini = 557.073 uV, v_off_fin = 549.010 uV 13:30:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.874 uVs 13:30:52 Integrated Voltage Measurement... 13:31:01 Voltage Offset Correction: v_off_ini = 563.886 uV, v_off_fin = 580.696 uV 13:31:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.386 uVs 13:31:04 I2X Average and RMS of Measurements VT = -119.873 +- 6.415 uVs I2X = 11.029 +- 0.590 uTm^2 13:31:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:31:11 Integrated Voltage Measurement... 13:31:20 Voltage Offset Correction: v_off_ini = 571.862 uV, v_off_fin = 575.861 uV 13:31:20 Integrated Voltage Measurement dXYus = 1.0002 mm, dXYds = 0.0000 mm dXY = 1.0002 mm VT = -258.955 uVs 13:31:21 Integrated Voltage Measurement... 13:31:30 Voltage Offset Correction: v_off_ini = 581.961 uV, v_off_fin = 579.559 uV 13:31:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.528 uVs 13:31:30 Integrated Voltage Measurement... 13:31:39 Voltage Offset Correction: v_off_ini = 578.992 uV, v_off_fin = 577.807 uV 13:31:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.382 uVs 13:31:39 Integrated Voltage Measurement... 13:31:48 Voltage Offset Correction: v_off_ini = 566.286 uV, v_off_fin = 568.399 uV 13:31:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.857 uVs 13:31:48 Integrated Voltage Measurement... 13:31:57 Voltage Offset Correction: v_off_ini = 575.549 uV, v_off_fin = 573.660 uV 13:31:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.950 uVs 13:31:57 Integrated Voltage Measurement... 13:32:06 Voltage Offset Correction: v_off_ini = 566.790 uV, v_off_fin = 575.570 uV 13:32:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.491 uVs 13:32:08 I2Y Average and RMS of Measurements VT = -268.527 +- 11.137 uVs I2Y = -24.704 +- 1.026 uTm^2 13:32:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:24 Integrated Voltage Measurement... 13:32:33 Voltage Offset Correction: v_off_ini = 581.438 uV, v_off_fin = 592.082 uV 13:32:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.509 uVs 13:32:33 Integrated Voltage Measurement... 13:32:42 Voltage Offset Correction: v_off_ini = 575.116 uV, v_off_fin = 569.752 uV 13:32:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.886 uVs 13:32:42 Integrated Voltage Measurement... 13:32:51 Voltage Offset Correction: v_off_ini = 571.397 uV, v_off_fin = 583.999 uV 13:32:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.594 uVs 13:32:51 Integrated Voltage Measurement... 13:33:00 Voltage Offset Correction: v_off_ini = 592.944 uV, v_off_fin = 595.500 uV 13:33:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.969 uVs 13:33:00 Integrated Voltage Measurement... 13:33:09 Voltage Offset Correction: v_off_ini = 591.759 uV, v_off_fin = 585.679 uV 13:33:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.384 uVs 13:33:09 Integrated Voltage Measurement... 13:33:18 Voltage Offset Correction: v_off_ini = 581.114 uV, v_off_fin = 580.200 uV 13:33:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.715 uVs 13:33:23 I1X Average and RMS of Measurements VT = -132.010 +- 7.466 uVs I1X = 26.402 +- 1.493 uTm 13:33:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:29 Integrated Voltage Measurement... 13:33:38 Voltage Offset Correction: v_off_ini = 604.738 uV, v_off_fin = 590.255 uV 13:33:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -143.463 uVs 13:33:38 Integrated Voltage Measurement... 13:33:47 Voltage Offset Correction: v_off_ini = 600.594 uV, v_off_fin = 599.080 uV 13:33:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 142.168 uVs 13:33:47 Integrated Voltage Measurement... 13:33:56 Voltage Offset Correction: v_off_ini = 599.014 uV, v_off_fin = 582.518 uV 13:33:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -134.648 uVs 13:33:56 Integrated Voltage Measurement... 13:34:05 Voltage Offset Correction: v_off_ini = 594.345 uV, v_off_fin = 608.883 uV 13:34:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 139.760 uVs 13:34:05 Integrated Voltage Measurement... 13:34:14 Voltage Offset Correction: v_off_ini = 583.841 uV, v_off_fin = 581.008 uV 13:34:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -131.402 uVs 13:34:14 Integrated Voltage Measurement... 13:34:23 Voltage Offset Correction: v_off_ini = 581.571 uV, v_off_fin = 599.011 uV 13:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 149.406 uVs 13:34:28 I1Y Average and RMS of Measurements VT = -140.141 +- 2.298 uVs I1Y = -28.024 +- 0.461 uTm 13:34:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:35 Integrated Voltage Measurement... 13:34:44 Voltage Offset Correction: v_off_ini = 585.171 uV, v_off_fin = 580.792 uV 13:34:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -157.404 uVs 13:34:44 Integrated Voltage Measurement... 13:34:53 Voltage Offset Correction: v_off_ini = 585.869 uV, v_off_fin = 599.618 uV 13:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.308 uVs 13:34:53 Integrated Voltage Measurement... 13:35:02 Voltage Offset Correction: v_off_ini = 584.677 uV, v_off_fin = 576.497 uV 13:35:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.799 uVs 13:35:02 Integrated Voltage Measurement... 13:35:11 Voltage Offset Correction: v_off_ini = 591.756 uV, v_off_fin = 588.020 uV 13:35:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.918 uVs 13:35:11 Integrated Voltage Measurement... 13:35:20 Voltage Offset Correction: v_off_ini = 576.428 uV, v_off_fin = 565.186 uV 13:35:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -133.586 uVs 13:35:21 Integrated Voltage Measurement... 13:35:30 Voltage Offset Correction: v_off_ini = 579.207 uV, v_off_fin = 582.408 uV 13:35:30 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 110.493 uVs 13:35:32 I2X Average and RMS of Measurements VT = -127.418 +- 5.431 uVs I2X = 11.723 +- 0.498 uTm^2 13:35:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:40 Integrated Voltage Measurement... 13:35:49 Voltage Offset Correction: v_off_ini = 586.745 uV, v_off_fin = 584.922 uV 13:35:49 Integrated Voltage Measurement dXYus = 1.0002 mm, dXYds = 0.0000 mm dXY = 1.0002 mm VT = -257.508 uVs 13:35:49 Integrated Voltage Measurement... 13:35:58 Voltage Offset Correction: v_off_ini = 574.517 uV, v_off_fin = 576.519 uV 13:35:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.533 uVs 13:35:58 Integrated Voltage Measurement... 13:36:07 Voltage Offset Correction: v_off_ini = 579.985 uV, v_off_fin = 569.517 uV 13:36:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.512 uVs 13:36:07 Integrated Voltage Measurement... 13:36:16 Voltage Offset Correction: v_off_ini = 579.692 uV, v_off_fin = 583.863 uV 13:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.971 uVs 13:36:16 Integrated Voltage Measurement... 13:36:25 Voltage Offset Correction: v_off_ini = 581.195 uV, v_off_fin = 583.244 uV 13:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.668 uVs 13:36:25 Integrated Voltage Measurement... 13:36:34 Voltage Offset Correction: v_off_ini = 589.457 uV, v_off_fin = 585.980 uV 13:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.889 uVs 13:36:36 I2Y Average and RMS of Measurements VT = -250.680 +- 6.761 uVs I2Y = -23.062 +- 0.621 uTm^2 13:36:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:55 Integrated Voltage Measurement... 13:37:04 Voltage Offset Correction: v_off_ini = 577.839 uV, v_off_fin = 564.309 uV 13:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.049 uVs 13:37:04 Integrated Voltage Measurement... 13:37:13 Voltage Offset Correction: v_off_ini = 576.235 uV, v_off_fin = 577.448 uV 13:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.513 uVs 13:37:13 Integrated Voltage Measurement... 13:37:22 Voltage Offset Correction: v_off_ini = 570.238 uV, v_off_fin = 577.975 uV 13:37:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.259 uVs 13:37:22 Integrated Voltage Measurement... 13:37:31 Voltage Offset Correction: v_off_ini = 578.328 uV, v_off_fin = 579.976 uV 13:37:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.303 uVs 13:37:31 Integrated Voltage Measurement... 13:37:40 Voltage Offset Correction: v_off_ini = 572.229 uV, v_off_fin = 573.657 uV 13:37:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.447 uVs 13:37:40 Integrated Voltage Measurement... 13:37:49 Voltage Offset Correction: v_off_ini = 573.008 uV, v_off_fin = 579.346 uV 13:37:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.684 uVs 13:37:53 I1X Average and RMS of Measurements VT = -137.876 +- 3.206 uVs I1X = 27.575 +- 0.641 uTm 13:37:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:00 Integrated Voltage Measurement... 13:38:09 Voltage Offset Correction: v_off_ini = 569.615 uV, v_off_fin = 561.392 uV 13:38:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -128.876 uVs 13:38:09 Integrated Voltage Measurement... 13:38:18 Voltage Offset Correction: v_off_ini = 593.808 uV, v_off_fin = 599.951 uV 13:38:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.464 uVs 13:38:18 Integrated Voltage Measurement... 13:38:26 Voltage Offset Correction: v_off_ini = 581.819 uV, v_off_fin = 567.475 uV 13:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -147.052 uVs 13:38:27 Integrated Voltage Measurement... 13:38:35 Voltage Offset Correction: v_off_ini = 581.296 uV, v_off_fin = 585.531 uV 13:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 138.653 uVs 13:38:35 Integrated Voltage Measurement... 13:38:44 Voltage Offset Correction: v_off_ini = 575.791 uV, v_off_fin = 555.211 uV 13:38:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -152.010 uVs 13:38:44 Integrated Voltage Measurement... 13:38:53 Voltage Offset Correction: v_off_ini = 569.134 uV, v_off_fin = 571.774 uV 13:38:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 135.283 uVs 13:38:58 I1Y Average and RMS of Measurements VT = -141.056 +- 3.119 uVs I1Y = -28.210 +- 0.624 uTm 13:39:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:05 Integrated Voltage Measurement... 13:39:14 Voltage Offset Correction: v_off_ini = 564.361 uV, v_off_fin = 562.583 uV 13:39:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -135.974 uVs 13:39:14 Integrated Voltage Measurement... 13:39:23 Voltage Offset Correction: v_off_ini = 568.829 uV, v_off_fin = 577.023 uV 13:39:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.177 uVs 13:39:23 Integrated Voltage Measurement... 13:39:32 Voltage Offset Correction: v_off_ini = 568.843 uV, v_off_fin = 557.432 uV 13:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.474 uVs 13:39:32 Integrated Voltage Measurement... 13:39:41 Voltage Offset Correction: v_off_ini = 557.839 uV, v_off_fin = 573.035 uV 13:39:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.573 uVs 13:39:41 Integrated Voltage Measurement... 13:39:50 Voltage Offset Correction: v_off_ini = 564.688 uV, v_off_fin = 550.238 uV 13:39:50 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -117.468 uVs 13:39:50 Integrated Voltage Measurement... 13:39:59 Voltage Offset Correction: v_off_ini = 568.224 uV, v_off_fin = 581.891 uV 13:39:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.658 uVs 13:40:02 I2X Average and RMS of Measurements VT = -125.054 +- 9.585 uVs I2X = 11.505 +- 0.881 uTm^2 13:40:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:40:09 Integrated Voltage Measurement... 13:40:18 Voltage Offset Correction: v_off_ini = 573.113 uV, v_off_fin = 551.104 uV 13:40:18 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -244.307 uVs 13:40:19 Integrated Voltage Measurement... 13:40:28 Voltage Offset Correction: v_off_ini = 573.029 uV, v_off_fin = 572.100 uV 13:40:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.659 uVs 13:40:28 Integrated Voltage Measurement... 13:40:37 Voltage Offset Correction: v_off_ini = 566.237 uV, v_off_fin = 564.968 uV 13:40:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.347 uVs 13:40:37 Integrated Voltage Measurement... 13:40:46 Voltage Offset Correction: v_off_ini = 568.496 uV, v_off_fin = 572.766 uV 13:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.889 uVs 13:40:46 Integrated Voltage Measurement... 13:40:55 Voltage Offset Correction: v_off_ini = 567.373 uV, v_off_fin = 561.871 uV 13:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.211 uVs 13:40:55 Integrated Voltage Measurement... 13:41:04 Voltage Offset Correction: v_off_ini = 565.829 uV, v_off_fin = 559.468 uV 13:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.392 uVs 13:41:06 I2Y Average and RMS of Measurements VT = -241.467 +- 3.527 uVs I2Y = -22.215 +- 0.325 uTm^2 13:41:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:41:24 Integrated Voltage Measurement... 13:41:33 Voltage Offset Correction: v_off_ini = 567.654 uV, v_off_fin = 567.963 uV 13:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.324 uVs 13:41:33 Integrated Voltage Measurement... 13:41:42 Voltage Offset Correction: v_off_ini = 544.228 uV, v_off_fin = 559.585 uV 13:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.010 uVs 13:41:42 Integrated Voltage Measurement... 13:41:51 Voltage Offset Correction: v_off_ini = 553.437 uV, v_off_fin = 539.767 uV 13:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.755 uVs 13:41:51 Integrated Voltage Measurement... 13:42:00 Voltage Offset Correction: v_off_ini = 556.943 uV, v_off_fin = 561.251 uV 13:42:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.944 uVs 13:42:00 Integrated Voltage Measurement... 13:42:09 Voltage Offset Correction: v_off_ini = 560.312 uV, v_off_fin = 554.396 uV 13:42:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.659 uVs 13:42:09 Integrated Voltage Measurement... 13:42:18 Voltage Offset Correction: v_off_ini = 559.225 uV, v_off_fin = 555.626 uV 13:42:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.715 uVs 13:42:23 I1X Average and RMS of Measurements VT = -133.068 +- 6.067 uVs I1X = 26.614 +- 1.214 uTm 13:42:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:29 Integrated Voltage Measurement... 13:42:38 Voltage Offset Correction: v_off_ini = 541.940 uV, v_off_fin = 542.356 uV 13:42:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -125.678 uVs 13:42:38 Integrated Voltage Measurement... 13:42:47 Voltage Offset Correction: v_off_ini = 547.282 uV, v_off_fin = 556.032 uV 13:42:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.807 uVs 13:42:47 Integrated Voltage Measurement... 13:42:56 Voltage Offset Correction: v_off_ini = 541.572 uV, v_off_fin = 535.900 uV 13:42:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.097 uVs 13:42:56 Integrated Voltage Measurement... 13:43:05 Voltage Offset Correction: v_off_ini = 549.455 uV, v_off_fin = 561.916 uV 13:43:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.858 uVs 13:43:05 Integrated Voltage Measurement... 13:43:14 Voltage Offset Correction: v_off_ini = 554.061 uV, v_off_fin = 539.006 uV 13:43:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.313 uVs 13:43:14 Integrated Voltage Measurement... 13:43:23 Voltage Offset Correction: v_off_ini = 528.829 uV, v_off_fin = 548.714 uV 13:43:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 156.792 uVs 13:43:27 I1Y Average and RMS of Measurements VT = -147.257 +- 6.540 uVs I1Y = -29.450 +- 1.307 uTm 13:43:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:35 Integrated Voltage Measurement... 13:43:44 Voltage Offset Correction: v_off_ini = 525.512 uV, v_off_fin = 526.429 uV 13:43:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.525 uVs 13:43:44 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = 538.188 uV, v_off_fin = 555.522 uV 13:43:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.043 uVs 13:43:53 Integrated Voltage Measurement... 13:44:02 Voltage Offset Correction: v_off_ini = 527.263 uV, v_off_fin = 520.434 uV 13:44:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -132.567 uVs 13:44:02 Integrated Voltage Measurement... 13:44:11 Voltage Offset Correction: v_off_ini = 527.436 uV, v_off_fin = 545.120 uV 13:44:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.356 uVs 13:44:11 Integrated Voltage Measurement... 13:44:20 Voltage Offset Correction: v_off_ini = 538.131 uV, v_off_fin = 532.887 uV 13:44:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -144.641 uVs 13:44:20 Integrated Voltage Measurement... 13:44:29 Voltage Offset Correction: v_off_ini = 546.794 uV, v_off_fin = 549.329 uV 13:44:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 106.508 uVs 13:44:32 I2X Average and RMS of Measurements VT = -122.440 +- 6.198 uVs I2X = 11.265 +- 0.571 uTm^2 13:44:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:39 Integrated Voltage Measurement... 13:44:48 Voltage Offset Correction: v_off_ini = 548.114 uV, v_off_fin = 553.356 uV 13:44:48 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -248.412 uVs 13:44:48 Integrated Voltage Measurement... 13:44:57 Voltage Offset Correction: v_off_ini = 545.005 uV, v_off_fin = 534.882 uV 13:44:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.682 uVs 13:44:57 Integrated Voltage Measurement... 13:45:06 Voltage Offset Correction: v_off_ini = 538.416 uV, v_off_fin = 533.840 uV 13:45:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.527 uVs 13:45:06 Integrated Voltage Measurement... 13:45:15 Voltage Offset Correction: v_off_ini = 520.040 uV, v_off_fin = 538.265 uV 13:45:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.963 uVs 13:45:15 Integrated Voltage Measurement... 13:45:24 Voltage Offset Correction: v_off_ini = 535.588 uV, v_off_fin = 536.897 uV 13:45:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.400 uVs 13:45:24 Integrated Voltage Measurement... 13:45:33 Voltage Offset Correction: v_off_ini = 541.940 uV, v_off_fin = 545.161 uV 13:45:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.356 uVs 13:45:36 I2Y Average and RMS of Measurements VT = -241.223 +- 3.429 uVs I2Y = -22.192 +- 0.315 uTm^2 13:45:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:54 Integrated Voltage Measurement... 13:46:03 Voltage Offset Correction: v_off_ini = 548.847 uV, v_off_fin = 533.201 uV 13:46:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.696 uVs 13:46:03 Integrated Voltage Measurement... 13:46:12 Voltage Offset Correction: v_off_ini = 532.205 uV, v_off_fin = 541.972 uV 13:46:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.018 uVs 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = 538.978 uV, v_off_fin = 532.103 uV 13:46:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.374 uVs 13:46:21 Integrated Voltage Measurement... 13:46:30 Voltage Offset Correction: v_off_ini = 540.747 uV, v_off_fin = 538.094 uV 13:46:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.387 uVs 13:46:30 Integrated Voltage Measurement... 13:46:39 Voltage Offset Correction: v_off_ini = 539.673 uV, v_off_fin = 536.151 uV 13:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.057 uVs 13:46:39 Integrated Voltage Measurement... 13:46:48 Voltage Offset Correction: v_off_ini = 545.590 uV, v_off_fin = 547.193 uV 13:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.630 uVs 13:46:52 I1X Average and RMS of Measurements VT = -119.527 +- 4.939 uVs I1X = 23.906 +- 0.988 uTm 13:46:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:59 Integrated Voltage Measurement... 13:47:08 Voltage Offset Correction: v_off_ini = 532.548 uV, v_off_fin = 525.066 uV 13:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -156.905 uVs 13:47:08 Integrated Voltage Measurement... 13:47:17 Voltage Offset Correction: v_off_ini = 540.620 uV, v_off_fin = 531.717 uV 13:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.323 uVs 13:47:17 Integrated Voltage Measurement... 13:47:26 Voltage Offset Correction: v_off_ini = 537.903 uV, v_off_fin = 527.616 uV 13:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.067 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = 545.902 uV, v_off_fin = 545.226 uV 13:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.303 uVs 13:47:35 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = 542.996 uV, v_off_fin = 528.400 uV 13:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -155.791 uVs 13:47:44 Integrated Voltage Measurement... 13:47:53 Voltage Offset Correction: v_off_ini = 530.612 uV, v_off_fin = 547.450 uV 13:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.266 uVs 13:47:57 I1Y Average and RMS of Measurements VT = -160.609 +- 4.306 uVs I1Y = -32.120 +- 0.861 uTm 13:48:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:05 Integrated Voltage Measurement... 13:48:14 Voltage Offset Correction: v_off_ini = 540.225 uV, v_off_fin = 522.278 uV 13:48:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -124.193 uVs 13:48:14 Integrated Voltage Measurement... 13:48:23 Voltage Offset Correction: v_off_ini = 537.980 uV, v_off_fin = 541.770 uV 13:48:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 116.235 uVs 13:48:23 Integrated Voltage Measurement... 13:48:32 Voltage Offset Correction: v_off_ini = 516.843 uV, v_off_fin = 512.694 uV 13:48:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.163 uVs 13:48:32 Integrated Voltage Measurement... 13:48:41 Voltage Offset Correction: v_off_ini = 520.833 uV, v_off_fin = 529.089 uV 13:48:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.351 uVs 13:48:41 Integrated Voltage Measurement... 13:48:50 Voltage Offset Correction: v_off_ini = 534.707 uV, v_off_fin = 528.827 uV 13:48:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.705 uVs 13:48:50 Integrated Voltage Measurement... 13:48:59 Voltage Offset Correction: v_off_ini = 545.092 uV, v_off_fin = 546.388 uV 13:48:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.573 uVs 13:49:01 I2X Average and RMS of Measurements VT = -111.537 +- 6.748 uVs I2X = 10.261 +- 0.620 uTm^2 13:49:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:09 Integrated Voltage Measurement... 13:49:18 Voltage Offset Correction: v_off_ini = 518.547 uV, v_off_fin = 513.664 uV 13:49:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.990 uVs 13:49:18 Integrated Voltage Measurement... 13:49:27 Voltage Offset Correction: v_off_ini = 523.232 uV, v_off_fin = 523.152 uV 13:49:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.112 uVs 13:49:27 Integrated Voltage Measurement... 13:49:36 Voltage Offset Correction: v_off_ini = 520.401 uV, v_off_fin = 528.029 uV 13:49:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.458 uVs 13:49:36 Integrated Voltage Measurement... 13:49:45 Voltage Offset Correction: v_off_ini = 530.751 uV, v_off_fin = 531.853 uV 13:49:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.891 uVs 13:49:45 Integrated Voltage Measurement... 13:49:54 Voltage Offset Correction: v_off_ini = 525.164 uV, v_off_fin = 535.639 uV 13:49:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.912 uVs 13:49:54 Integrated Voltage Measurement... 13:50:03 Voltage Offset Correction: v_off_ini = 528.815 uV, v_off_fin = 528.793 uV 13:50:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.692 uVs 13:50:06 I2Y Average and RMS of Measurements VT = -240.342 +- 6.130 uVs I2Y = -22.112 +- 0.564 uTm^2 13:50:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:24 Integrated Voltage Measurement... 13:50:33 Voltage Offset Correction: v_off_ini = 511.076 uV, v_off_fin = 524.902 uV 13:50:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.673 uVs 13:50:33 Integrated Voltage Measurement... 13:50:42 Voltage Offset Correction: v_off_ini = 526.449 uV, v_off_fin = 520.712 uV 13:50:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.850 uVs 13:50:42 Integrated Voltage Measurement... 13:50:51 Voltage Offset Correction: v_off_ini = 532.681 uV, v_off_fin = 526.494 uV 13:50:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.385 uVs 13:50:51 Integrated Voltage Measurement... 13:51:00 Voltage Offset Correction: v_off_ini = 532.826 uV, v_off_fin = 523.559 uV 13:51:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.752 uVs 13:51:00 Integrated Voltage Measurement... 13:51:09 Voltage Offset Correction: v_off_ini = 489.165 uV, v_off_fin = 510.255 uV 13:51:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.356 uVs 13:51:09 Integrated Voltage Measurement... 13:51:18 Voltage Offset Correction: v_off_ini = 500.184 uV, v_off_fin = 515.294 uV 13:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.276 uVs 13:51:22 I1X Average and RMS of Measurements VT = -114.216 +- 16.715 uVs I1X = 22.843 +- 3.343 uTm 13:51:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:29 Integrated Voltage Measurement... 13:51:38 Voltage Offset Correction: v_off_ini = 492.937 uV, v_off_fin = 487.031 uV 13:51:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.094 uVs 13:51:38 Integrated Voltage Measurement... 13:51:47 Voltage Offset Correction: v_off_ini = 512.432 uV, v_off_fin = 518.418 uV 13:51:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.357 uVs 13:51:47 Integrated Voltage Measurement... 13:51:56 Voltage Offset Correction: v_off_ini = 494.615 uV, v_off_fin = 488.225 uV 13:51:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.804 uVs 13:51:56 Integrated Voltage Measurement... 13:52:05 Voltage Offset Correction: v_off_ini = 515.112 uV, v_off_fin = 526.049 uV 13:52:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.001 uVs 13:52:05 Integrated Voltage Measurement... 13:52:14 Voltage Offset Correction: v_off_ini = 508.191 uV, v_off_fin = 501.185 uV 13:52:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.913 uVs 13:52:14 Integrated Voltage Measurement... 13:52:23 Voltage Offset Correction: v_off_ini = 513.890 uV, v_off_fin = 507.702 uV 13:52:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.874 uVs 13:52:27 I1Y Average and RMS of Measurements VT = -175.674 +- 13.029 uVs I1Y = -35.134 +- 2.605 uTm 13:52:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:35 Integrated Voltage Measurement... 13:52:44 Voltage Offset Correction: v_off_ini = 484.054 uV, v_off_fin = 493.837 uV 13:52:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -121.920 uVs 13:52:44 Integrated Voltage Measurement... 13:52:53 Voltage Offset Correction: v_off_ini = 491.876 uV, v_off_fin = 501.225 uV 13:52:53 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 101.573 uVs 13:52:53 Integrated Voltage Measurement... 13:53:02 Voltage Offset Correction: v_off_ini = 487.506 uV, v_off_fin = 485.583 uV 13:53:02 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -110.145 uVs 13:53:02 Integrated Voltage Measurement... 13:53:11 Voltage Offset Correction: v_off_ini = 490.655 uV, v_off_fin = 497.937 uV 13:53:11 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 83.901 uVs 13:53:11 Integrated Voltage Measurement... 13:53:20 Voltage Offset Correction: v_off_ini = 490.582 uV, v_off_fin = 476.965 uV 13:53:20 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -88.934 uVs 13:53:20 Integrated Voltage Measurement... 13:53:29 Voltage Offset Correction: v_off_ini = 493.887 uV, v_off_fin = 500.048 uV 13:53:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.402 uVs 13:53:32 I2X Average and RMS of Measurements VT = -103.146 +- 6.261 uVs I2X = 9.490 +- 0.575 uTm^2 13:53:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:39 Integrated Voltage Measurement... 13:53:48 Voltage Offset Correction: v_off_ini = 482.134 uV, v_off_fin = 480.177 uV 13:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.774 uVs 13:53:48 Integrated Voltage Measurement... 13:53:57 Voltage Offset Correction: v_off_ini = 490.728 uV, v_off_fin = 495.053 uV 13:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.127 uVs 13:53:57 Integrated Voltage Measurement... 13:54:06 Voltage Offset Correction: v_off_ini = 488.737 uV, v_off_fin = 490.094 uV 13:54:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.298 uVs 13:54:06 Integrated Voltage Measurement... 13:54:15 Voltage Offset Correction: v_off_ini = 486.191 uV, v_off_fin = 487.330 uV 13:54:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.835 uVs 13:54:15 Integrated Voltage Measurement... 13:54:24 Voltage Offset Correction: v_off_ini = 486.630 uV, v_off_fin = 480.298 uV 13:54:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.943 uVs 13:54:25 Integrated Voltage Measurement... 13:54:34 Voltage Offset Correction: v_off_ini = 501.274 uV, v_off_fin = 498.749 uV 13:54:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.572 uVs 13:54:36 I2Y Average and RMS of Measurements VT = -240.425 +- 1.685 uVs I2Y = -22.119 +- 0.155 uTm^2 13:54:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:54 Integrated Voltage Measurement... 13:55:03 Voltage Offset Correction: v_off_ini = 481.845 uV, v_off_fin = 495.695 uV 13:55:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -83.223 uVs 13:55:03 Integrated Voltage Measurement... 13:55:12 Voltage Offset Correction: v_off_ini = 486.649 uV, v_off_fin = 485.438 uV 13:55:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 131.189 uVs 13:55:12 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = 481.624 uV, v_off_fin = 489.635 uV 13:55:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.972 uVs 13:55:21 Integrated Voltage Measurement... 13:55:30 Voltage Offset Correction: v_off_ini = 510.038 uV, v_off_fin = 503.580 uV 13:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.316 uVs 13:55:30 Integrated Voltage Measurement... 13:55:39 Voltage Offset Correction: v_off_ini = 492.904 uV, v_off_fin = 492.760 uV 13:55:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.269 uVs 13:55:39 Integrated Voltage Measurement... 13:55:48 Voltage Offset Correction: v_off_ini = 505.092 uV, v_off_fin = 510.484 uV 13:55:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.402 uVs 13:55:53 I1X Average and RMS of Measurements VT = -103.562 +- 4.099 uVs I1X = 20.715 +- 0.822 uTm 13:55:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:59 Integrated Voltage Measurement... 13:56:08 Voltage Offset Correction: v_off_ini = 512.395 uV, v_off_fin = 487.602 uV 13:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.182 uVs 13:56:08 Integrated Voltage Measurement... 13:56:17 Voltage Offset Correction: v_off_ini = 511.649 uV, v_off_fin = 516.403 uV 13:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.998 uVs 13:56:17 Integrated Voltage Measurement... 13:56:26 Voltage Offset Correction: v_off_ini = 496.823 uV, v_off_fin = 478.914 uV 13:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.028 uVs 13:56:26 Integrated Voltage Measurement... 13:56:35 Voltage Offset Correction: v_off_ini = 508.599 uV, v_off_fin = 516.691 uV 13:56:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.107 uVs 13:56:35 Integrated Voltage Measurement... 13:56:44 Voltage Offset Correction: v_off_ini = 502.882 uV, v_off_fin = 502.878 uV 13:56:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.947 uVs 13:56:44 Integrated Voltage Measurement... 13:56:53 Voltage Offset Correction: v_off_ini = 505.546 uV, v_off_fin = 517.190 uV 13:56:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.737 uVs 13:56:58 I1Y Average and RMS of Measurements VT = -179.333 +- 4.420 uVs I1Y = -35.865 +- 0.884 uTm 13:57:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:05 Integrated Voltage Measurement... 13:57:14 Voltage Offset Correction: v_off_ini = 500.322 uV, v_off_fin = 499.286 uV 13:57:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -113.361 uVs 13:57:14 Integrated Voltage Measurement... 13:57:23 Voltage Offset Correction: v_off_ini = 508.136 uV, v_off_fin = 505.732 uV 13:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.988 uVs 13:57:23 Integrated Voltage Measurement... 13:57:32 Voltage Offset Correction: v_off_ini = 512.621 uV, v_off_fin = 513.159 uV 13:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.764 uVs 13:57:32 Integrated Voltage Measurement... 13:57:41 Voltage Offset Correction: v_off_ini = 507.055 uV, v_off_fin = 528.881 uV 13:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.218 uVs 13:57:41 Integrated Voltage Measurement... 13:57:50 Voltage Offset Correction: v_off_ini = 513.515 uV, v_off_fin = 506.721 uV 13:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.103 uVs 13:57:51 Integrated Voltage Measurement... 13:58:00 Voltage Offset Correction: v_off_ini = 523.539 uV, v_off_fin = 529.606 uV 13:58:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.644 uVs 13:58:02 I2X Average and RMS of Measurements VT = -105.846 +- 1.148 uVs I2X = 9.738 +- 0.105 uTm^2 13:58:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:10 Integrated Voltage Measurement... 13:58:19 Voltage Offset Correction: v_off_ini = 513.460 uV, v_off_fin = 513.439 uV 13:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.951 uVs 13:58:19 Integrated Voltage Measurement... 13:58:28 Voltage Offset Correction: v_off_ini = 507.926 uV, v_off_fin = 500.347 uV 13:58:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.557 uVs 13:58:28 Integrated Voltage Measurement... 13:58:37 Voltage Offset Correction: v_off_ini = 506.850 uV, v_off_fin = 511.477 uV 13:58:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.129 uVs 13:58:37 Integrated Voltage Measurement... 13:58:46 Voltage Offset Correction: v_off_ini = 515.861 uV, v_off_fin = 514.133 uV 13:58:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.057 uVs 13:58:46 Integrated Voltage Measurement... 13:58:55 Voltage Offset Correction: v_off_ini = 503.734 uV, v_off_fin = 496.158 uV 13:58:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.693 uVs 13:58:55 Integrated Voltage Measurement... 13:59:04 Voltage Offset Correction: v_off_ini = 504.359 uV, v_off_fin = 507.739 uV 13:59:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.327 uVs 13:59:06 I2Y Average and RMS of Measurements VT = -245.286 +- 5.095 uVs I2Y = -22.566 +- 0.469 uTm^2 13:59:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:25 Integrated Voltage Measurement... 13:59:34 Voltage Offset Correction: v_off_ini = 509.435 uV, v_off_fin = 513.507 uV 13:59:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -120.675 uVs 13:59:34 Integrated Voltage Measurement... 13:59:43 Voltage Offset Correction: v_off_ini = 523.882 uV, v_off_fin = 499.851 uV 13:59:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.506 uVs 13:59:43 Integrated Voltage Measurement... 13:59:52 Voltage Offset Correction: v_off_ini = 514.949 uV, v_off_fin = 502.830 uV 13:59:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.366 uVs 13:59:52 Integrated Voltage Measurement... 14:00:01 Voltage Offset Correction: v_off_ini = 512.076 uV, v_off_fin = 513.443 uV 14:00:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.912 uVs 14:00:01 Integrated Voltage Measurement... 14:00:10 Voltage Offset Correction: v_off_ini = 499.890 uV, v_off_fin = 500.568 uV 14:00:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.363 uVs 14:00:10 Integrated Voltage Measurement... 14:00:19 Voltage Offset Correction: v_off_ini = 502.229 uV, v_off_fin = 519.431 uV 14:00:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.112 uVs 14:00:23 I1X Average and RMS of Measurements VT = -105.156 +- 5.551 uVs I1X = 21.032 +- 1.111 uTm 14:00:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:30 Integrated Voltage Measurement... 14:00:39 Voltage Offset Correction: v_off_ini = 517.293 uV, v_off_fin = 496.435 uV 14:00:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.538 uVs 14:00:39 Integrated Voltage Measurement... 14:00:48 Voltage Offset Correction: v_off_ini = 509.676 uV, v_off_fin = 513.146 uV 14:00:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.718 uVs 14:00:48 Integrated Voltage Measurement... 14:00:57 Voltage Offset Correction: v_off_ini = 512.746 uV, v_off_fin = 505.749 uV 14:00:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.678 uVs 14:00:57 Integrated Voltage Measurement... 14:01:06 Voltage Offset Correction: v_off_ini = 521.918 uV, v_off_fin = 527.765 uV 14:01:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 191.508 uVs 14:01:06 Integrated Voltage Measurement... 14:01:15 Voltage Offset Correction: v_off_ini = 509.067 uV, v_off_fin = 497.301 uV 14:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -200.952 uVs 14:01:15 Integrated Voltage Measurement... 14:01:24 Voltage Offset Correction: v_off_ini = 520.493 uV, v_off_fin = 524.228 uV 14:01:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.023 uVs 14:01:28 I1Y Average and RMS of Measurements VT = -195.236 +- 3.726 uVs I1Y = -39.042 +- 0.746 uTm 14:01:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:36 Integrated Voltage Measurement... 14:01:45 Voltage Offset Correction: v_off_ini = 516.954 uV, v_off_fin = 513.901 uV 14:01:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.231 uVs 14:01:45 Integrated Voltage Measurement... 14:01:54 Voltage Offset Correction: v_off_ini = 520.115 uV, v_off_fin = 528.600 uV 14:01:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.119 uVs 14:01:54 Integrated Voltage Measurement... 14:02:03 Voltage Offset Correction: v_off_ini = 505.683 uV, v_off_fin = 509.223 uV 14:02:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.677 uVs 14:02:03 Integrated Voltage Measurement... 14:02:12 Voltage Offset Correction: v_off_ini = 493.840 uV, v_off_fin = 522.831 uV 14:02:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.686 uVs 14:02:12 Integrated Voltage Measurement... 14:02:21 Voltage Offset Correction: v_off_ini = 510.563 uV, v_off_fin = 505.391 uV 14:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.196 uVs 14:02:21 Integrated Voltage Measurement... 14:02:30 Voltage Offset Correction: v_off_ini = 524.860 uV, v_off_fin = 531.408 uV 14:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.074 uVs 14:02:32 I2X Average and RMS of Measurements VT = -95.331 +- 1.566 uVs I2X = 8.771 +- 0.144 uTm^2 14:02:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = 507.287 uV, v_off_fin = 504.326 uV 14:02:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -237.429 uVs 14:02:49 Integrated Voltage Measurement... 14:02:58 Voltage Offset Correction: v_off_ini = 516.184 uV, v_off_fin = 513.229 uV 14:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.583 uVs 14:02:58 Integrated Voltage Measurement... 14:03:07 Voltage Offset Correction: v_off_ini = 503.309 uV, v_off_fin = 508.857 uV 14:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.251 uVs 14:03:07 Integrated Voltage Measurement... 14:03:16 Voltage Offset Correction: v_off_ini = 510.080 uV, v_off_fin = 497.805 uV 14:03:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.725 uVs 14:03:16 Integrated Voltage Measurement... 14:03:25 Voltage Offset Correction: v_off_ini = 495.859 uV, v_off_fin = 505.843 uV 14:03:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -250.050 uVs 14:03:25 Integrated Voltage Measurement... 14:03:34 Voltage Offset Correction: v_off_ini = 514.421 uV, v_off_fin = 509.119 uV 14:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.501 uVs 14:03:37 I2Y Average and RMS of Measurements VT = -246.923 +- 6.078 uVs I2Y = -22.718 +- 0.559 uTm^2 14:03:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm