SLAC Magnetic Measurements Date: 08-08-2025 Time: 14:04:35 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16342 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 14:04:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:45 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:04:47 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:04:49 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:04:50 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:05:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:05:38 Integrated Voltage Measurement... 14:05:47 Voltage Offset Correction: v_off_ini = 496.804 uV, v_off_fin = 493.230 uV 14:05:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -41.125 uVs 14:05:47 Integrated Voltage Measurement... 14:05:56 Voltage Offset Correction: v_off_ini = 486.851 uV, v_off_fin = 489.993 uV 14:05:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.395 uVs 14:05:56 Integrated Voltage Measurement... 14:06:05 Voltage Offset Correction: v_off_ini = 473.856 uV, v_off_fin = 494.070 uV 14:06:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -14.702 uVs 14:06:05 Integrated Voltage Measurement... 14:06:14 Voltage Offset Correction: v_off_ini = 495.766 uV, v_off_fin = 504.935 uV 14:06:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.646 uVs 14:06:14 Integrated Voltage Measurement... 14:06:23 Voltage Offset Correction: v_off_ini = 488.212 uV, v_off_fin = 513.893 uV 14:06:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -13.667 uVs 14:06:23 Integrated Voltage Measurement... 14:06:32 Voltage Offset Correction: v_off_ini = 505.686 uV, v_off_fin = 501.343 uV 14:06:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.470 uVs 14:06:36 I1X Average and RMS of Measurements VT = -33.501 +- 7.063 uVs I1X = 6.701 +- 1.413 uTm 14:06:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:06:43 Integrated Voltage Measurement... 14:06:52 Voltage Offset Correction: v_off_ini = 493.040 uV, v_off_fin = 483.751 uV 14:06:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -291.575 uVs 14:06:52 Integrated Voltage Measurement... 14:07:01 Voltage Offset Correction: v_off_ini = 498.606 uV, v_off_fin = 521.494 uV 14:07:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.450 uVs 14:07:01 Integrated Voltage Measurement... 14:07:10 Voltage Offset Correction: v_off_ini = 499.172 uV, v_off_fin = 486.626 uV 14:07:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.857 uVs 14:07:10 Integrated Voltage Measurement... 14:07:19 Voltage Offset Correction: v_off_ini = 502.533 uV, v_off_fin = 518.045 uV 14:07:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.730 uVs 14:07:19 Integrated Voltage Measurement... 14:07:28 Voltage Offset Correction: v_off_ini = 506.646 uV, v_off_fin = 492.719 uV 14:07:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.583 uVs 14:07:28 Integrated Voltage Measurement... 14:07:37 Voltage Offset Correction: v_off_ini = 512.897 uV, v_off_fin = 519.477 uV 14:07:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.990 uVs 14:07:41 I1Y Average and RMS of Measurements VT = -289.531 +- 2.707 uVs I1Y = -57.907 +- 0.540 uTm 14:07:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:07:49 Integrated Voltage Measurement... 14:07:58 Voltage Offset Correction: v_off_ini = 495.394 uV, v_off_fin = 494.378 uV 14:07:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -29.137 uVs 14:07:58 Integrated Voltage Measurement... 14:08:07 Voltage Offset Correction: v_off_ini = 502.408 uV, v_off_fin = 511.682 uV 14:08:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 15.374 uVs 14:08:07 Integrated Voltage Measurement... 14:08:16 Voltage Offset Correction: v_off_ini = 503.643 uV, v_off_fin = 488.911 uV 14:08:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -30.475 uVs 14:08:16 Integrated Voltage Measurement... 14:08:25 Voltage Offset Correction: v_off_ini = 504.769 uV, v_off_fin = 514.026 uV 14:08:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 4.043 uVs 14:08:25 Integrated Voltage Measurement... 14:08:34 Voltage Offset Correction: v_off_ini = 486.199 uV, v_off_fin = 504.821 uV 14:08:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -14.039 uVs 14:08:34 Integrated Voltage Measurement... 14:08:43 Voltage Offset Correction: v_off_ini = 507.660 uV, v_off_fin = 517.039 uV 14:08:43 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = -3.476 uVs 14:08:46 I2X Average and RMS of Measurements VT = -14.932 +- 7.122 uVs I2X = 1.374 +- 0.655 uTm^2 14:08:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:08:53 Integrated Voltage Measurement... 14:09:02 Voltage Offset Correction: v_off_ini = 485.589 uV, v_off_fin = 502.174 uV 14:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -509.163 uVs 14:09:02 Integrated Voltage Measurement... 14:09:11 Voltage Offset Correction: v_off_ini = 501.958 uV, v_off_fin = 497.912 uV 14:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.420 uVs 14:09:11 Integrated Voltage Measurement... 14:09:20 Voltage Offset Correction: v_off_ini = 496.353 uV, v_off_fin = 493.324 uV 14:09:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -517.819 uVs 14:09:20 Integrated Voltage Measurement... 14:09:29 Voltage Offset Correction: v_off_ini = 481.333 uV, v_off_fin = 500.111 uV 14:09:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 534.282 uVs 14:09:30 Integrated Voltage Measurement... 14:09:38 Voltage Offset Correction: v_off_ini = 492.708 uV, v_off_fin = 498.730 uV 14:09:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -505.592 uVs 14:09:39 Integrated Voltage Measurement... 14:09:48 Voltage Offset Correction: v_off_ini = 488.224 uV, v_off_fin = 492.674 uV 14:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 525.205 uVs 14:09:50 I2Y Average and RMS of Measurements VT = -516.414 +- 7.489 uVs I2Y = -47.510 +- 0.689 uTm^2 14:09:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:09:59 Integrated Voltage Measurement... 14:10:08 Voltage Offset Correction: v_off_ini = 493.329 uV, v_off_fin = 487.260 uV 14:10:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -42.614 uVs 14:10:08 Integrated Voltage Measurement... 14:10:17 Voltage Offset Correction: v_off_ini = 497.754 uV, v_off_fin = 493.042 uV 14:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.230 uVs 14:10:17 Integrated Voltage Measurement... 14:10:26 Voltage Offset Correction: v_off_ini = 492.973 uV, v_off_fin = 494.108 uV 14:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.442 uVs 14:10:26 Integrated Voltage Measurement... 14:10:35 Voltage Offset Correction: v_off_ini = 506.647 uV, v_off_fin = 503.220 uV 14:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.626 uVs 14:10:35 Integrated Voltage Measurement... 14:10:44 Voltage Offset Correction: v_off_ini = 500.288 uV, v_off_fin = 502.854 uV 14:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.687 uVs 14:10:44 Integrated Voltage Measurement... 14:10:53 Voltage Offset Correction: v_off_ini = 496.707 uV, v_off_fin = 489.208 uV 14:10:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.888 uVs 14:10:57 I1X Average and RMS of Measurements VT = -57.081 +- 7.615 uVs I1X = 11.417 +- 1.522 uTm 14:11:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:11:04 Integrated Voltage Measurement... 14:11:13 Voltage Offset Correction: v_off_ini = 501.664 uV, v_off_fin = 480.658 uV 14:11:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.117 uVs 14:11:13 Integrated Voltage Measurement... 14:11:22 Voltage Offset Correction: v_off_ini = 494.516 uV, v_off_fin = 508.144 uV 14:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.799 uVs 14:11:22 Integrated Voltage Measurement... 14:11:31 Voltage Offset Correction: v_off_ini = 492.697 uV, v_off_fin = 482.554 uV 14:11:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.727 uVs 14:11:31 Integrated Voltage Measurement... 14:11:40 Voltage Offset Correction: v_off_ini = 508.133 uV, v_off_fin = 520.989 uV 14:11:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.294 uVs 14:11:40 Integrated Voltage Measurement... 14:11:49 Voltage Offset Correction: v_off_ini = 489.757 uV, v_off_fin = 494.188 uV 14:11:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -299.947 uVs 14:11:49 Integrated Voltage Measurement... 14:11:58 Voltage Offset Correction: v_off_ini = 494.119 uV, v_off_fin = 504.427 uV 14:11:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 284.540 uVs 14:12:02 I1Y Average and RMS of Measurements VT = -288.738 +- 3.500 uVs I1Y = -57.748 +- 0.700 uTm 14:12:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:12:10 Integrated Voltage Measurement... 14:12:19 Voltage Offset Correction: v_off_ini = 495.318 uV, v_off_fin = 498.586 uV 14:12:19 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -56.273 uVs 14:12:19 Integrated Voltage Measurement... 14:12:28 Voltage Offset Correction: v_off_ini = 500.908 uV, v_off_fin = 509.739 uV 14:12:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 19.956 uVs 14:12:28 Integrated Voltage Measurement... 14:12:37 Voltage Offset Correction: v_off_ini = 488.925 uV, v_off_fin = 486.872 uV 14:12:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -31.073 uVs 14:12:37 Integrated Voltage Measurement... 14:12:46 Voltage Offset Correction: v_off_ini = 492.133 uV, v_off_fin = 505.862 uV 14:12:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.560 uVs 14:12:46 Integrated Voltage Measurement... 14:12:55 Voltage Offset Correction: v_off_ini = 511.109 uV, v_off_fin = 498.546 uV 14:12:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.806 uVs 14:12:55 Integrated Voltage Measurement... 14:13:04 Voltage Offset Correction: v_off_ini = 501.582 uV, v_off_fin = 509.632 uV 14:13:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.707 uVs 14:13:06 I2X Average and RMS of Measurements VT = -34.896 +- 3.326 uVs I2X = 3.210 +- 0.306 uTm^2 14:13:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:13:14 Integrated Voltage Measurement... 14:13:23 Voltage Offset Correction: v_off_ini = 520.296 uV, v_off_fin = 516.824 uV 14:13:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.745 uVs 14:13:23 Integrated Voltage Measurement... 14:13:32 Voltage Offset Correction: v_off_ini = 524.041 uV, v_off_fin = 510.093 uV 14:13:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.921 uVs 14:13:32 Integrated Voltage Measurement... 14:13:41 Voltage Offset Correction: v_off_ini = 511.294 uV, v_off_fin = 506.025 uV 14:13:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.713 uVs 14:13:41 Integrated Voltage Measurement... 14:13:50 Voltage Offset Correction: v_off_ini = 517.247 uV, v_off_fin = 510.037 uV 14:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 481.982 uVs 14:13:50 Integrated Voltage Measurement... 14:13:59 Voltage Offset Correction: v_off_ini = 516.165 uV, v_off_fin = 509.867 uV 14:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -521.067 uVs 14:13:59 Integrated Voltage Measurement... 14:14:08 Voltage Offset Correction: v_off_ini = 503.953 uV, v_off_fin = 518.626 uV 14:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 521.974 uVs 14:14:11 I2Y Average and RMS of Measurements VT = -503.234 +- 17.121 uVs I2Y = -46.297 +- 1.575 uTm^2 14:14:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:20 Integrated Voltage Measurement... 14:14:28 Voltage Offset Correction: v_off_ini = 508.912 uV, v_off_fin = 511.958 uV 14:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.318 uVs 14:14:29 Integrated Voltage Measurement... 14:14:37 Voltage Offset Correction: v_off_ini = 512.150 uV, v_off_fin = 502.957 uV 14:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.935 uVs 14:14:38 Integrated Voltage Measurement... 14:14:46 Voltage Offset Correction: v_off_ini = 499.647 uV, v_off_fin = 501.136 uV 14:14:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.165 uVs 14:14:47 Integrated Voltage Measurement... 14:14:55 Voltage Offset Correction: v_off_ini = 505.107 uV, v_off_fin = 504.489 uV 14:14:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.826 uVs 14:14:56 Integrated Voltage Measurement... 14:15:05 Voltage Offset Correction: v_off_ini = 501.368 uV, v_off_fin = 504.886 uV 14:15:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.824 uVs 14:15:05 Integrated Voltage Measurement... 14:15:13 Voltage Offset Correction: v_off_ini = 504.597 uV, v_off_fin = 506.323 uV 14:15:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.788 uVs 14:15:18 I1X Average and RMS of Measurements VT = -61.309 +- 6.235 uVs I1X = 12.262 +- 1.247 uTm 14:15:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:24 Integrated Voltage Measurement... 14:15:33 Voltage Offset Correction: v_off_ini = 511.128 uV, v_off_fin = 488.136 uV 14:15:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.068 uVs 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = 511.687 uV, v_off_fin = 515.359 uV 14:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.367 uVs 14:15:42 Integrated Voltage Measurement... 14:15:51 Voltage Offset Correction: v_off_ini = 501.846 uV, v_off_fin = 490.852 uV 14:15:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.157 uVs 14:15:51 Integrated Voltage Measurement... 14:16:00 Voltage Offset Correction: v_off_ini = 497.977 uV, v_off_fin = 516.448 uV 14:16:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.903 uVs 14:16:00 Integrated Voltage Measurement... 14:16:09 Voltage Offset Correction: v_off_ini = 505.108 uV, v_off_fin = 493.487 uV 14:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.909 uVs 14:16:09 Integrated Voltage Measurement... 14:16:18 Voltage Offset Correction: v_off_ini = 490.155 uV, v_off_fin = 502.734 uV 14:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.023 uVs 14:16:23 I1Y Average and RMS of Measurements VT = -275.905 +- 4.817 uVs I1Y = -55.181 +- 0.963 uTm 14:16:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:30 Integrated Voltage Measurement... 14:16:39 Voltage Offset Correction: v_off_ini = 506.414 uV, v_off_fin = 499.841 uV 14:16:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -40.056 uVs 14:16:39 Integrated Voltage Measurement... 14:16:48 Voltage Offset Correction: v_off_ini = 514.786 uV, v_off_fin = 523.566 uV 14:16:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 18.999 uVs 14:16:48 Integrated Voltage Measurement... 14:16:57 Voltage Offset Correction: v_off_ini = 507.543 uV, v_off_fin = 502.570 uV 14:16:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.428 uVs 14:16:57 Integrated Voltage Measurement... 14:17:06 Voltage Offset Correction: v_off_ini = 511.714 uV, v_off_fin = 520.621 uV 14:17:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 46.553 uVs 14:17:06 Integrated Voltage Measurement... 14:17:15 Voltage Offset Correction: v_off_ini = 516.437 uV, v_off_fin = 510.405 uV 14:17:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.353 uVs 14:17:15 Integrated Voltage Measurement... 14:17:24 Voltage Offset Correction: v_off_ini = 520.034 uV, v_off_fin = 522.896 uV 14:17:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.090 uVs 14:17:27 I2X Average and RMS of Measurements VT = -39.413 +- 8.040 uVs I2X = 3.626 +- 0.740 uTm^2 14:17:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:34 Integrated Voltage Measurement... 14:17:43 Voltage Offset Correction: v_off_ini = 506.195 uV, v_off_fin = 524.676 uV 14:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.355 uVs 14:17:43 Integrated Voltage Measurement... 14:17:52 Voltage Offset Correction: v_off_ini = 525.979 uV, v_off_fin = 521.615 uV 14:17:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.937 uVs 14:17:52 Integrated Voltage Measurement... 14:18:01 Voltage Offset Correction: v_off_ini = 515.208 uV, v_off_fin = 533.208 uV 14:18:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -479.454 uVs 14:18:01 Integrated Voltage Measurement... 14:18:10 Voltage Offset Correction: v_off_ini = 513.494 uV, v_off_fin = 520.827 uV 14:18:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.827 uVs 14:18:10 Integrated Voltage Measurement... 14:18:19 Voltage Offset Correction: v_off_ini = 516.328 uV, v_off_fin = 513.456 uV 14:18:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -455.597 uVs 14:18:20 Integrated Voltage Measurement... 14:18:28 Voltage Offset Correction: v_off_ini = 528.391 uV, v_off_fin = 523.318 uV 14:18:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 506.884 uVs 14:18:31 I2Y Average and RMS of Measurements VT = -486.509 +- 4.697 uVs I2Y = -44.759 +- 0.432 uTm^2 14:18:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:18:40 Integrated Voltage Measurement... 14:18:49 Voltage Offset Correction: v_off_ini = 525.908 uV, v_off_fin = 532.215 uV 14:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.792 uVs 14:18:49 Integrated Voltage Measurement... 14:18:58 Voltage Offset Correction: v_off_ini = 505.838 uV, v_off_fin = 523.884 uV 14:18:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.827 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = 511.463 uV, v_off_fin = 525.067 uV 14:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.172 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = 519.992 uV, v_off_fin = 516.158 uV 14:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.533 uVs 14:19:16 Integrated Voltage Measurement... 14:19:25 Voltage Offset Correction: v_off_ini = 519.102 uV, v_off_fin = 508.791 uV 14:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.031 uVs 14:19:25 Integrated Voltage Measurement... 14:19:34 Voltage Offset Correction: v_off_ini = 515.939 uV, v_off_fin = 515.659 uV 14:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.941 uVs 14:19:38 I1X Average and RMS of Measurements VT = -60.549 +- 4.877 uVs I1X = 12.110 +- 0.976 uTm 14:19:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:19:45 Integrated Voltage Measurement... 14:19:54 Voltage Offset Correction: v_off_ini = 518.400 uV, v_off_fin = 518.523 uV 14:19:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -270.121 uVs 14:19:54 Integrated Voltage Measurement... 14:20:03 Voltage Offset Correction: v_off_ini = 534.911 uV, v_off_fin = 546.033 uV 14:20:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.525 uVs 14:20:03 Integrated Voltage Measurement... 14:20:12 Voltage Offset Correction: v_off_ini = 519.311 uV, v_off_fin = 519.048 uV 14:20:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.953 uVs 14:20:12 Integrated Voltage Measurement... 14:20:21 Voltage Offset Correction: v_off_ini = 525.267 uV, v_off_fin = 541.018 uV 14:20:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.142 uVs 14:20:21 Integrated Voltage Measurement... 14:20:30 Voltage Offset Correction: v_off_ini = 521.180 uV, v_off_fin = 515.632 uV 14:20:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.383 uVs 14:20:30 Integrated Voltage Measurement... 14:20:39 Voltage Offset Correction: v_off_ini = 522.655 uV, v_off_fin = 545.920 uV 14:20:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.938 uVs 14:20:43 I1Y Average and RMS of Measurements VT = -267.510 +- 1.447 uVs I1Y = -53.503 +- 0.289 uTm 14:20:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:20:50 Integrated Voltage Measurement... 14:20:59 Voltage Offset Correction: v_off_ini = 519.125 uV, v_off_fin = 517.510 uV 14:20:59 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -34.880 uVs 14:21:00 Integrated Voltage Measurement... 14:21:08 Voltage Offset Correction: v_off_ini = 510.955 uV, v_off_fin = 533.607 uV 14:21:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.172 uVs 14:21:09 Integrated Voltage Measurement... 14:21:18 Voltage Offset Correction: v_off_ini = 511.174 uV, v_off_fin = 501.807 uV 14:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.198 uVs 14:21:18 Integrated Voltage Measurement... 14:21:27 Voltage Offset Correction: v_off_ini = 519.329 uV, v_off_fin = 529.779 uV 14:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.869 uVs 14:21:27 Integrated Voltage Measurement... 14:21:36 Voltage Offset Correction: v_off_ini = 504.116 uV, v_off_fin = 503.916 uV 14:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.376 uVs 14:21:36 Integrated Voltage Measurement... 14:21:45 Voltage Offset Correction: v_off_ini = 523.735 uV, v_off_fin = 530.774 uV 14:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.497 uVs 14:21:47 I2X Average and RMS of Measurements VT = -47.499 +- 7.816 uVs I2X = 4.370 +- 0.719 uTm^2 14:21:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:21:55 Integrated Voltage Measurement... 14:22:04 Voltage Offset Correction: v_off_ini = 517.956 uV, v_off_fin = 507.443 uV 14:22:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.103 uVs 14:22:04 Integrated Voltage Measurement... 14:22:13 Voltage Offset Correction: v_off_ini = 500.127 uV, v_off_fin = 514.404 uV 14:22:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.652 uVs 14:22:13 Integrated Voltage Measurement... 14:22:22 Voltage Offset Correction: v_off_ini = 511.830 uV, v_off_fin = 510.789 uV 14:22:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -487.453 uVs 14:22:22 Integrated Voltage Measurement... 14:22:31 Voltage Offset Correction: v_off_ini = 534.266 uV, v_off_fin = 519.038 uV 14:22:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.377 uVs 14:22:31 Integrated Voltage Measurement... 14:22:40 Voltage Offset Correction: v_off_ini = 528.717 uV, v_off_fin = 517.334 uV 14:22:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -497.594 uVs 14:22:40 Integrated Voltage Measurement... 14:22:49 Voltage Offset Correction: v_off_ini = 532.791 uV, v_off_fin = 517.901 uV 14:22:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.107 uVs 14:22:51 I2Y Average and RMS of Measurements VT = -480.214 +- 3.546 uVs I2Y = -44.180 +- 0.326 uTm^2 14:22:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:23:00 Integrated Voltage Measurement... 14:23:09 Voltage Offset Correction: v_off_ini = 526.679 uV, v_off_fin = 517.885 uV 14:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.639 uVs 14:23:09 Integrated Voltage Measurement... 14:23:18 Voltage Offset Correction: v_off_ini = 524.374 uV, v_off_fin = 526.450 uV 14:23:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.527 uVs 14:23:18 Integrated Voltage Measurement... 14:23:27 Voltage Offset Correction: v_off_ini = 508.291 uV, v_off_fin = 511.088 uV 14:23:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.344 uVs 14:23:27 Integrated Voltage Measurement... 14:23:36 Voltage Offset Correction: v_off_ini = 522.379 uV, v_off_fin = 525.646 uV 14:23:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.974 uVs 14:23:36 Integrated Voltage Measurement... 14:23:45 Voltage Offset Correction: v_off_ini = 522.547 uV, v_off_fin = 520.552 uV 14:23:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.489 uVs 14:23:45 Integrated Voltage Measurement... 14:23:54 Voltage Offset Correction: v_off_ini = 516.437 uV, v_off_fin = 513.474 uV 14:23:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.964 uVs 14:23:58 I1X Average and RMS of Measurements VT = -76.323 +- 4.600 uVs I1X = 15.265 +- 0.920 uTm 14:24:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:24:05 Integrated Voltage Measurement... 14:24:14 Voltage Offset Correction: v_off_ini = 511.588 uV, v_off_fin = 507.451 uV 14:24:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.654 uVs 14:24:14 Integrated Voltage Measurement... 14:24:23 Voltage Offset Correction: v_off_ini = 520.364 uV, v_off_fin = 539.762 uV 14:24:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.871 uVs 14:24:23 Integrated Voltage Measurement... 14:24:32 Voltage Offset Correction: v_off_ini = 521.248 uV, v_off_fin = 510.938 uV 14:24:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.647 uVs 14:24:32 Integrated Voltage Measurement... 14:24:41 Voltage Offset Correction: v_off_ini = 519.136 uV, v_off_fin = 531.082 uV 14:24:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.720 uVs 14:24:41 Integrated Voltage Measurement... 14:24:50 Voltage Offset Correction: v_off_ini = 518.088 uV, v_off_fin = 515.404 uV 14:24:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.081 uVs 14:24:50 Integrated Voltage Measurement... 14:24:59 Voltage Offset Correction: v_off_ini = 538.497 uV, v_off_fin = 542.851 uV 14:24:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.028 uVs 14:25:03 I1Y Average and RMS of Measurements VT = -249.833 +- 2.629 uVs I1Y = -49.967 +- 0.526 uTm 14:25:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:25:11 Integrated Voltage Measurement... 14:25:20 Voltage Offset Correction: v_off_ini = 551.260 uV, v_off_fin = 547.042 uV 14:25:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -77.659 uVs 14:25:20 Integrated Voltage Measurement... 14:25:29 Voltage Offset Correction: v_off_ini = 562.564 uV, v_off_fin = 565.811 uV 14:25:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 54.792 uVs 14:25:29 Integrated Voltage Measurement... 14:25:38 Voltage Offset Correction: v_off_ini = 538.261 uV, v_off_fin = 524.247 uV 14:25:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.216 uVs 14:25:38 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = 540.063 uV, v_off_fin = 549.137 uV 14:25:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 30.437 uVs 14:25:47 Integrated Voltage Measurement... 14:25:56 Voltage Offset Correction: v_off_ini = 537.415 uV, v_off_fin = 527.830 uV 14:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.663 uVs 14:25:56 Integrated Voltage Measurement... 14:26:05 Voltage Offset Correction: v_off_ini = 517.933 uV, v_off_fin = 538.251 uV 14:26:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.227 uVs 14:26:08 I2X Average and RMS of Measurements VT = -51.499 +- 11.443 uVs I2X = 4.738 +- 1.053 uTm^2 14:26:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:26:15 Integrated Voltage Measurement... 14:26:24 Voltage Offset Correction: v_off_ini = 527.120 uV, v_off_fin = 532.631 uV 14:26:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.528 uVs 14:26:24 Integrated Voltage Measurement... 14:26:33 Voltage Offset Correction: v_off_ini = 534.540 uV, v_off_fin = 523.850 uV 14:26:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 454.774 uVs 14:26:33 Integrated Voltage Measurement... 14:26:42 Voltage Offset Correction: v_off_ini = 529.730 uV, v_off_fin = 522.373 uV 14:26:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -441.766 uVs 14:26:42 Integrated Voltage Measurement... 14:26:51 Voltage Offset Correction: v_off_ini = 529.421 uV, v_off_fin = 547.054 uV 14:26:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.544 uVs 14:26:51 Integrated Voltage Measurement... 14:27:00 Voltage Offset Correction: v_off_ini = 527.792 uV, v_off_fin = 522.331 uV 14:27:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.342 uVs 14:27:00 Integrated Voltage Measurement... 14:27:09 Voltage Offset Correction: v_off_ini = 532.475 uV, v_off_fin = 549.846 uV 14:27:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.495 uVs 14:27:12 I2Y Average and RMS of Measurements VT = -449.908 +- 4.444 uVs I2Y = -41.392 +- 0.409 uTm^2 14:27:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:27:24 Integrated Voltage Measurement... 14:27:33 Voltage Offset Correction: v_off_ini = 548.192 uV, v_off_fin = 527.810 uV 14:27:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -37.536 uVs 14:27:33 Integrated Voltage Measurement... 14:27:42 Voltage Offset Correction: v_off_ini = 522.500 uV, v_off_fin = 520.431 uV 14:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.823 uVs 14:27:42 Integrated Voltage Measurement... 14:27:51 Voltage Offset Correction: v_off_ini = 536.188 uV, v_off_fin = 517.636 uV 14:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.850 uVs 14:27:51 Integrated Voltage Measurement... 14:28:00 Voltage Offset Correction: v_off_ini = 516.774 uV, v_off_fin = 535.952 uV 14:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.189 uVs 14:28:00 Integrated Voltage Measurement... 14:28:09 Voltage Offset Correction: v_off_ini = 531.894 uV, v_off_fin = 521.248 uV 14:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -26.024 uVs 14:28:09 Integrated Voltage Measurement... 14:28:18 Voltage Offset Correction: v_off_ini = 524.174 uV, v_off_fin = 534.014 uV 14:28:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 15.388 uVs 14:28:22 I1X Average and RMS of Measurements VT = -28.468 +- 5.688 uVs I1X = 5.694 +- 1.138 uTm 14:28:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:28:29 Integrated Voltage Measurement... 14:28:38 Voltage Offset Correction: v_off_ini = 532.575 uV, v_off_fin = 517.706 uV 14:28:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.154 uVs 14:28:38 Integrated Voltage Measurement... 14:28:47 Voltage Offset Correction: v_off_ini = 526.171 uV, v_off_fin = 530.519 uV 14:28:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.953 uVs 14:28:47 Integrated Voltage Measurement... 14:28:56 Voltage Offset Correction: v_off_ini = 519.027 uV, v_off_fin = 505.665 uV 14:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.167 uVs 14:28:56 Integrated Voltage Measurement... 14:29:05 Voltage Offset Correction: v_off_ini = 530.146 uV, v_off_fin = 529.686 uV 14:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.479 uVs 14:29:05 Integrated Voltage Measurement... 14:29:14 Voltage Offset Correction: v_off_ini = 506.247 uV, v_off_fin = 510.340 uV 14:29:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.713 uVs 14:29:14 Integrated Voltage Measurement... 14:29:23 Voltage Offset Correction: v_off_ini = 515.196 uV, v_off_fin = 526.318 uV 14:29:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.291 uVs 14:29:27 I1Y Average and RMS of Measurements VT = -261.960 +- 2.596 uVs I1Y = -52.392 +- 0.519 uTm 14:29:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:29:32 Integrated Voltage Measurement... 14:29:41 Voltage Offset Correction: v_off_ini = 505.812 uV, v_off_fin = 501.740 uV 14:29:41 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -27.589 uVs 14:29:41 Integrated Voltage Measurement... 14:29:50 Voltage Offset Correction: v_off_ini = 507.404 uV, v_off_fin = 518.387 uV 14:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.418 uVs 14:29:50 Integrated Voltage Measurement... 14:29:59 Voltage Offset Correction: v_off_ini = 510.942 uV, v_off_fin = 511.463 uV 14:29:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.730 uVs 14:29:59 Integrated Voltage Measurement... 14:30:08 Voltage Offset Correction: v_off_ini = 516.647 uV, v_off_fin = 514.641 uV 14:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.651 uVs 14:30:08 Integrated Voltage Measurement... 14:30:17 Voltage Offset Correction: v_off_ini = 518.755 uV, v_off_fin = 511.855 uV 14:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.081 uVs 14:30:17 Integrated Voltage Measurement... 14:30:26 Voltage Offset Correction: v_off_ini = 512.900 uV, v_off_fin = 528.500 uV 14:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.634 uVs 14:30:28 I2X Average and RMS of Measurements VT = -12.774 +- 9.004 uVs I2X = 1.175 +- 0.828 uTm^2 14:30:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:30:34 Integrated Voltage Measurement... 14:30:43 Voltage Offset Correction: v_off_ini = 503.244 uV, v_off_fin = 523.533 uV 14:30:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.107 uVs 14:30:43 Integrated Voltage Measurement... 14:30:52 Voltage Offset Correction: v_off_ini = 523.546 uV, v_off_fin = 529.282 uV 14:30:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 487.820 uVs 14:30:52 Integrated Voltage Measurement... 14:31:01 Voltage Offset Correction: v_off_ini = 525.068 uV, v_off_fin = 532.764 uV 14:31:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -480.005 uVs 14:31:01 Integrated Voltage Measurement... 14:31:10 Voltage Offset Correction: v_off_ini = 536.866 uV, v_off_fin = 526.885 uV 14:31:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 461.077 uVs 14:31:10 Integrated Voltage Measurement... 14:31:19 Voltage Offset Correction: v_off_ini = 530.108 uV, v_off_fin = 528.119 uV 14:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.565 uVs 14:31:19 Integrated Voltage Measurement... 14:31:28 Voltage Offset Correction: v_off_ini = 537.781 uV, v_off_fin = 523.403 uV 14:31:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.110 uVs 14:31:30 I2Y Average and RMS of Measurements VT = -475.947 +- 4.625 uVs I2Y = -43.787 +- 0.425 uTm^2 14:31:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:31:38 Integrated Voltage Measurement... 14:31:47 Voltage Offset Correction: v_off_ini = 527.542 uV, v_off_fin = 523.947 uV 14:31:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.896 uVs 14:31:47 Integrated Voltage Measurement... 14:31:56 Voltage Offset Correction: v_off_ini = 517.367 uV, v_off_fin = 530.964 uV 14:31:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.400 uVs 14:31:56 Integrated Voltage Measurement... 14:32:05 Voltage Offset Correction: v_off_ini = 538.650 uV, v_off_fin = 533.345 uV 14:32:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.185 uVs 14:32:05 Integrated Voltage Measurement... 14:32:14 Voltage Offset Correction: v_off_ini = 530.705 uV, v_off_fin = 539.954 uV 14:32:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.381 uVs 14:32:14 Integrated Voltage Measurement... 14:32:23 Voltage Offset Correction: v_off_ini = 527.621 uV, v_off_fin = 525.403 uV 14:32:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.990 uVs 14:32:23 Integrated Voltage Measurement... 14:32:32 Voltage Offset Correction: v_off_ini = 531.662 uV, v_off_fin = 538.512 uV 14:32:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.766 uVs 14:32:37 I1X Average and RMS of Measurements VT = -39.603 +- 4.459 uVs I1X = 7.921 +- 0.892 uTm 14:32:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:32:43 Integrated Voltage Measurement... 14:32:52 Voltage Offset Correction: v_off_ini = 523.377 uV, v_off_fin = 523.665 uV 14:32:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.132 uVs 14:32:52 Integrated Voltage Measurement... 14:33:01 Voltage Offset Correction: v_off_ini = 535.101 uV, v_off_fin = 538.863 uV 14:33:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.732 uVs 14:33:01 Integrated Voltage Measurement... 14:33:10 Voltage Offset Correction: v_off_ini = 514.727 uV, v_off_fin = 526.090 uV 14:33:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.806 uVs 14:33:10 Integrated Voltage Measurement... 14:33:19 Voltage Offset Correction: v_off_ini = 531.951 uV, v_off_fin = 560.281 uV 14:33:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.178 uVs 14:33:19 Integrated Voltage Measurement... 14:33:28 Voltage Offset Correction: v_off_ini = 539.131 uV, v_off_fin = 531.202 uV 14:33:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.157 uVs 14:33:28 Integrated Voltage Measurement... 14:33:37 Voltage Offset Correction: v_off_ini = 538.921 uV, v_off_fin = 555.020 uV 14:33:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.651 uVs 14:33:42 I1Y Average and RMS of Measurements VT = -269.276 +- 4.054 uVs I1Y = -53.855 +- 0.811 uTm 14:33:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:33:47 Integrated Voltage Measurement... 14:33:56 Voltage Offset Correction: v_off_ini = 544.088 uV, v_off_fin = 548.674 uV 14:33:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.767 uVs 14:33:56 Integrated Voltage Measurement... 14:34:05 Voltage Offset Correction: v_off_ini = 551.865 uV, v_off_fin = 562.573 uV 14:34:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.345 uVs 14:34:05 Integrated Voltage Measurement... 14:34:14 Voltage Offset Correction: v_off_ini = 545.905 uV, v_off_fin = 526.875 uV 14:34:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.855 uVs 14:34:14 Integrated Voltage Measurement... 14:34:23 Voltage Offset Correction: v_off_ini = 560.255 uV, v_off_fin = 547.238 uV 14:34:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.312 uVs 14:34:23 Integrated Voltage Measurement... 14:34:32 Voltage Offset Correction: v_off_ini = 539.373 uV, v_off_fin = 537.615 uV 14:34:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.420 uVs 14:34:32 Integrated Voltage Measurement... 14:34:41 Voltage Offset Correction: v_off_ini = 544.541 uV, v_off_fin = 559.203 uV 14:34:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.995 uVs 14:34:43 I2X Average and RMS of Measurements VT = -23.449 +- 4.430 uVs I2X = 2.157 +- 0.408 uTm^2 14:34:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:34:48 Integrated Voltage Measurement... 14:34:57 Voltage Offset Correction: v_off_ini = 550.336 uV, v_off_fin = 553.922 uV 14:34:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -476.776 uVs 14:34:57 Integrated Voltage Measurement... 14:35:06 Voltage Offset Correction: v_off_ini = 555.966 uV, v_off_fin = 559.030 uV 14:35:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 486.675 uVs 14:35:06 Integrated Voltage Measurement... 14:35:15 Voltage Offset Correction: v_off_ini = 563.746 uV, v_off_fin = 560.056 uV 14:35:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -500.339 uVs 14:35:15 Integrated Voltage Measurement... 14:35:24 Voltage Offset Correction: v_off_ini = 558.083 uV, v_off_fin = 545.154 uV 14:35:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.774 uVs 14:35:24 Integrated Voltage Measurement... 14:35:33 Voltage Offset Correction: v_off_ini = 562.536 uV, v_off_fin = 565.810 uV 14:35:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -479.841 uVs 14:35:33 Integrated Voltage Measurement... 14:35:42 Voltage Offset Correction: v_off_ini = 564.506 uV, v_off_fin = 550.811 uV 14:35:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.791 uVs 14:35:45 I2Y Average and RMS of Measurements VT = -486.033 +- 3.608 uVs I2Y = -44.715 +- 0.332 uTm^2 14:35:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:53 Integrated Voltage Measurement... 14:36:02 Voltage Offset Correction: v_off_ini = 567.507 uV, v_off_fin = 557.637 uV 14:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -41.676 uVs 14:36:02 Integrated Voltage Measurement... 14:36:11 Voltage Offset Correction: v_off_ini = 562.055 uV, v_off_fin = 559.849 uV 14:36:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.505 uVs 14:36:11 Integrated Voltage Measurement... 14:36:20 Voltage Offset Correction: v_off_ini = 564.190 uV, v_off_fin = 554.732 uV 14:36:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.154 uVs 14:36:20 Integrated Voltage Measurement... 14:36:29 Voltage Offset Correction: v_off_ini = 564.072 uV, v_off_fin = 567.953 uV 14:36:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.003 uVs 14:36:29 Integrated Voltage Measurement... 14:36:38 Voltage Offset Correction: v_off_ini = 563.130 uV, v_off_fin = 556.682 uV 14:36:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -50.412 uVs 14:36:38 Integrated Voltage Measurement... 14:36:47 Voltage Offset Correction: v_off_ini = 534.261 uV, v_off_fin = 558.320 uV 14:36:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 56.004 uVs 14:36:51 I1X Average and RMS of Measurements VT = -50.459 +- 3.796 uVs I1X = 10.092 +- 0.759 uTm 14:36:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:58 Integrated Voltage Measurement... 14:37:07 Voltage Offset Correction: v_off_ini = 548.986 uV, v_off_fin = 536.715 uV 14:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.486 uVs 14:37:07 Integrated Voltage Measurement... 14:37:16 Voltage Offset Correction: v_off_ini = 554.211 uV, v_off_fin = 557.617 uV 14:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.586 uVs 14:37:16 Integrated Voltage Measurement... 14:37:25 Voltage Offset Correction: v_off_ini = 552.784 uV, v_off_fin = 543.078 uV 14:37:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.156 uVs 14:37:25 Integrated Voltage Measurement... 14:37:34 Voltage Offset Correction: v_off_ini = 556.984 uV, v_off_fin = 564.909 uV 14:37:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.817 uVs 14:37:34 Integrated Voltage Measurement... 14:37:43 Voltage Offset Correction: v_off_ini = 555.420 uV, v_off_fin = 551.390 uV 14:37:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.311 uVs 14:37:43 Integrated Voltage Measurement... 14:37:52 Voltage Offset Correction: v_off_ini = 559.382 uV, v_off_fin = 571.499 uV 14:37:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.444 uVs 14:37:56 I1Y Average and RMS of Measurements VT = -273.467 +- 2.062 uVs I1Y = -54.693 +- 0.412 uTm 14:37:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:01 Integrated Voltage Measurement... 14:38:10 Voltage Offset Correction: v_off_ini = 562.609 uV, v_off_fin = 554.931 uV 14:38:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.783 uVs 14:38:10 Integrated Voltage Measurement... 14:38:19 Voltage Offset Correction: v_off_ini = 567.874 uV, v_off_fin = 574.467 uV 14:38:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.067 uVs 14:38:19 Integrated Voltage Measurement... 14:38:28 Voltage Offset Correction: v_off_ini = 581.106 uV, v_off_fin = 567.138 uV 14:38:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.705 uVs 14:38:28 Integrated Voltage Measurement... 14:38:37 Voltage Offset Correction: v_off_ini = 565.962 uV, v_off_fin = 580.030 uV 14:38:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.530 uVs 14:38:37 Integrated Voltage Measurement... 14:38:46 Voltage Offset Correction: v_off_ini = 579.750 uV, v_off_fin = 565.380 uV 14:38:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.210 uVs 14:38:46 Integrated Voltage Measurement... 14:38:55 Voltage Offset Correction: v_off_ini = 558.220 uV, v_off_fin = 575.548 uV 14:38:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.886 uVs 14:38:58 I2X Average and RMS of Measurements VT = -38.530 +- 4.870 uVs I2X = 3.545 +- 0.448 uTm^2 14:39:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:03 Integrated Voltage Measurement... 14:39:12 Voltage Offset Correction: v_off_ini = 576.808 uV, v_off_fin = 580.649 uV 14:39:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.791 uVs 14:39:12 Integrated Voltage Measurement... 14:39:21 Voltage Offset Correction: v_off_ini = 580.988 uV, v_off_fin = 584.456 uV 14:39:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 487.135 uVs 14:39:21 Integrated Voltage Measurement... 14:39:30 Voltage Offset Correction: v_off_ini = 574.158 uV, v_off_fin = 574.485 uV 14:39:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -512.133 uVs 14:39:30 Integrated Voltage Measurement... 14:39:39 Voltage Offset Correction: v_off_ini = 576.562 uV, v_off_fin = 570.440 uV 14:39:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 489.171 uVs 14:39:39 Integrated Voltage Measurement... 14:39:48 Voltage Offset Correction: v_off_ini = 572.566 uV, v_off_fin = 567.608 uV 14:39:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -496.939 uVs 14:39:48 Integrated Voltage Measurement... 14:39:57 Voltage Offset Correction: v_off_ini = 575.019 uV, v_off_fin = 580.735 uV 14:39:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 484.870 uVs 14:40:00 I2Y Average and RMS of Measurements VT = -494.006 +- 4.703 uVs I2Y = -45.449 +- 0.433 uTm^2 14:40:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:40:08 Integrated Voltage Measurement... 14:40:17 Voltage Offset Correction: v_off_ini = 583.205 uV, v_off_fin = 587.082 uV 14:40:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.231 uVs 14:40:17 Integrated Voltage Measurement... 14:40:26 Voltage Offset Correction: v_off_ini = 587.599 uV, v_off_fin = 574.951 uV 14:40:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.722 uVs 14:40:26 Integrated Voltage Measurement... 14:40:35 Voltage Offset Correction: v_off_ini = 581.576 uV, v_off_fin = 585.764 uV 14:40:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.752 uVs 14:40:35 Integrated Voltage Measurement... 14:40:44 Voltage Offset Correction: v_off_ini = 579.383 uV, v_off_fin = 590.222 uV 14:40:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.577 uVs 14:40:44 Integrated Voltage Measurement... 14:40:53 Voltage Offset Correction: v_off_ini = 569.689 uV, v_off_fin = 568.567 uV 14:40:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.761 uVs 14:40:53 Integrated Voltage Measurement... 14:41:02 Voltage Offset Correction: v_off_ini = 564.868 uV, v_off_fin = 566.812 uV 14:41:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.547 uVs 14:41:06 I1X Average and RMS of Measurements VT = -57.598 +- 5.682 uVs I1X = 11.520 +- 1.136 uTm 14:41:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:41:13 Integrated Voltage Measurement... 14:41:22 Voltage Offset Correction: v_off_ini = 574.751 uV, v_off_fin = 566.159 uV 14:41:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -270.046 uVs 14:41:22 Integrated Voltage Measurement... 14:41:31 Voltage Offset Correction: v_off_ini = 553.752 uV, v_off_fin = 584.359 uV 14:41:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 285.516 uVs 14:41:31 Integrated Voltage Measurement... 14:41:40 Voltage Offset Correction: v_off_ini = 559.810 uV, v_off_fin = 547.811 uV 14:41:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.090 uVs 14:41:40 Integrated Voltage Measurement... 14:41:49 Voltage Offset Correction: v_off_ini = 557.525 uV, v_off_fin = 572.751 uV 14:41:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 280.811 uVs 14:41:49 Integrated Voltage Measurement... 14:41:58 Voltage Offset Correction: v_off_ini = 558.609 uV, v_off_fin = 551.708 uV 14:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.977 uVs 14:41:58 Integrated Voltage Measurement... 14:42:07 Voltage Offset Correction: v_off_ini = 564.125 uV, v_off_fin = 569.554 uV 14:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 306.240 uVs 14:42:11 I1Y Average and RMS of Measurements VT = -285.613 +- 8.305 uVs I1Y = -57.119 +- 1.662 uTm 14:42:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:42:16 Integrated Voltage Measurement... 14:42:25 Voltage Offset Correction: v_off_ini = 550.147 uV, v_off_fin = 549.080 uV 14:42:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.828 uVs 14:42:25 Integrated Voltage Measurement... 14:42:34 Voltage Offset Correction: v_off_ini = 560.862 uV, v_off_fin = 561.571 uV 14:42:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.028 uVs 14:42:34 Integrated Voltage Measurement... 14:42:43 Voltage Offset Correction: v_off_ini = 555.751 uV, v_off_fin = 547.387 uV 14:42:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -53.353 uVs 14:42:43 Integrated Voltage Measurement... 14:42:52 Voltage Offset Correction: v_off_ini = 547.101 uV, v_off_fin = 557.073 uV 14:42:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.331 uVs 14:42:52 Integrated Voltage Measurement... 14:43:01 Voltage Offset Correction: v_off_ini = 566.798 uV, v_off_fin = 534.062 uV 14:43:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -56.512 uVs 14:43:01 Integrated Voltage Measurement... 14:43:10 Voltage Offset Correction: v_off_ini = 554.213 uV, v_off_fin = 561.980 uV 14:43:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 30.598 uVs 14:43:13 I2X Average and RMS of Measurements VT = -40.108 +- 2.914 uVs I2X = 3.690 +- 0.268 uTm^2 14:43:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:43:18 Integrated Voltage Measurement... 14:43:27 Voltage Offset Correction: v_off_ini = 557.226 uV, v_off_fin = 543.358 uV 14:43:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -487.636 uVs 14:43:27 Integrated Voltage Measurement... 14:43:36 Voltage Offset Correction: v_off_ini = 555.702 uV, v_off_fin = 544.408 uV 14:43:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.338 uVs 14:43:36 Integrated Voltage Measurement... 14:43:45 Voltage Offset Correction: v_off_ini = 541.545 uV, v_off_fin = 547.025 uV 14:43:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -500.135 uVs 14:43:45 Integrated Voltage Measurement... 14:43:54 Voltage Offset Correction: v_off_ini = 543.085 uV, v_off_fin = 547.173 uV 14:43:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 503.109 uVs 14:43:54 Integrated Voltage Measurement... 14:44:03 Voltage Offset Correction: v_off_ini = 549.056 uV, v_off_fin = 545.121 uV 14:44:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -493.943 uVs 14:44:03 Integrated Voltage Measurement... 14:44:12 Voltage Offset Correction: v_off_ini = 534.943 uV, v_off_fin = 544.274 uV 14:44:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 518.162 uVs 14:44:14 I2Y Average and RMS of Measurements VT = -500.387 +- 5.204 uVs I2Y = -46.036 +- 0.479 uTm^2 14:44:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:44:22 Integrated Voltage Measurement... 14:44:31 Voltage Offset Correction: v_off_ini = 543.495 uV, v_off_fin = 543.677 uV 14:44:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.725 uVs 14:44:31 Integrated Voltage Measurement... 14:44:40 Voltage Offset Correction: v_off_ini = 548.323 uV, v_off_fin = 538.239 uV 14:44:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.477 uVs 14:44:41 Integrated Voltage Measurement... 14:44:49 Voltage Offset Correction: v_off_ini = 536.419 uV, v_off_fin = 542.654 uV 14:44:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.165 uVs 14:44:50 Integrated Voltage Measurement... 14:44:58 Voltage Offset Correction: v_off_ini = 539.682 uV, v_off_fin = 550.196 uV 14:44:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.898 uVs 14:44:59 Integrated Voltage Measurement... 14:45:07 Voltage Offset Correction: v_off_ini = 545.697 uV, v_off_fin = 542.956 uV 14:45:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.657 uVs 14:45:08 Integrated Voltage Measurement... 14:45:16 Voltage Offset Correction: v_off_ini = 550.664 uV, v_off_fin = 547.483 uV 14:45:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.933 uVs 14:45:21 I1X Average and RMS of Measurements VT = -52.476 +- 2.870 uVs I1X = 10.495 +- 0.574 uTm 14:45:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:45:28 Integrated Voltage Measurement... 14:45:36 Voltage Offset Correction: v_off_ini = 539.952 uV, v_off_fin = 524.041 uV 14:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -275.594 uVs 14:45:37 Integrated Voltage Measurement... 14:45:45 Voltage Offset Correction: v_off_ini = 544.222 uV, v_off_fin = 557.836 uV 14:45:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 303.916 uVs 14:45:46 Integrated Voltage Measurement... 14:45:54 Voltage Offset Correction: v_off_ini = 541.272 uV, v_off_fin = 530.130 uV 14:45:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.522 uVs 14:45:54 Integrated Voltage Measurement... 14:46:03 Voltage Offset Correction: v_off_ini = 531.430 uV, v_off_fin = 548.468 uV 14:46:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 292.401 uVs 14:46:04 Integrated Voltage Measurement... 14:46:12 Voltage Offset Correction: v_off_ini = 534.067 uV, v_off_fin = 525.249 uV 14:46:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -269.267 uVs 14:46:12 Integrated Voltage Measurement... 14:46:21 Voltage Offset Correction: v_off_ini = 543.249 uV, v_off_fin = 558.024 uV 14:46:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.853 uVs 14:46:26 I1Y Average and RMS of Measurements VT = -280.759 +- 11.478 uVs I1Y = -56.148 +- 2.295 uTm 14:46:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:46:31 Integrated Voltage Measurement... 14:46:40 Voltage Offset Correction: v_off_ini = 535.335 uV, v_off_fin = 536.901 uV 14:46:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -31.652 uVs 14:46:40 Integrated Voltage Measurement... 14:46:49 Voltage Offset Correction: v_off_ini = 556.587 uV, v_off_fin = 559.508 uV 14:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.712 uVs 14:46:49 Integrated Voltage Measurement... 14:46:58 Voltage Offset Correction: v_off_ini = 560.704 uV, v_off_fin = 547.083 uV 14:46:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -31.216 uVs 14:46:58 Integrated Voltage Measurement... 14:47:07 Voltage Offset Correction: v_off_ini = 550.043 uV, v_off_fin = 560.817 uV 14:47:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.734 uVs 14:47:07 Integrated Voltage Measurement... 14:47:16 Voltage Offset Correction: v_off_ini = 552.895 uV, v_off_fin = 538.220 uV 14:47:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.156 uVs 14:47:16 Integrated Voltage Measurement... 14:47:25 Voltage Offset Correction: v_off_ini = 551.829 uV, v_off_fin = 568.135 uV 14:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.947 uVs 14:47:27 I2X Average and RMS of Measurements VT = -41.736 +- 2.782 uVs I2X = 3.840 +- 0.256 uTm^2 14:47:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:47:32 Integrated Voltage Measurement... 14:47:41 Voltage Offset Correction: v_off_ini = 561.518 uV, v_off_fin = 555.430 uV 14:47:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -498.013 uVs 14:47:41 Integrated Voltage Measurement... 14:47:50 Voltage Offset Correction: v_off_ini = 554.966 uV, v_off_fin = 553.613 uV 14:47:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 502.881 uVs 14:47:50 Integrated Voltage Measurement... 14:47:59 Voltage Offset Correction: v_off_ini = 561.642 uV, v_off_fin = 564.413 uV 14:47:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -503.840 uVs 14:48:00 Integrated Voltage Measurement... 14:48:08 Voltage Offset Correction: v_off_ini = 566.017 uV, v_off_fin = 562.884 uV 14:48:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 495.013 uVs 14:48:09 Integrated Voltage Measurement... 14:48:18 Voltage Offset Correction: v_off_ini = 567.126 uV, v_off_fin = 559.604 uV 14:48:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.877 uVs 14:48:18 Integrated Voltage Measurement... 14:48:27 Voltage Offset Correction: v_off_ini = 549.914 uV, v_off_fin = 568.001 uV 14:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 510.957 uVs 14:48:29 I2Y Average and RMS of Measurements VT = -499.430 +- 0.829 uVs I2Y = -45.948 +- 0.076 uTm^2 14:48:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:48:49 Integrated Voltage Measurement... 14:48:58 Voltage Offset Correction: v_off_ini = 565.196 uV, v_off_fin = 550.004 uV 14:48:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -33.219 uVs 14:48:58 Integrated Voltage Measurement... 14:49:07 Voltage Offset Correction: v_off_ini = 546.756 uV, v_off_fin = 557.467 uV 14:49:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.562 uVs 14:49:07 Integrated Voltage Measurement... 14:49:16 Voltage Offset Correction: v_off_ini = 560.743 uV, v_off_fin = 559.619 uV 14:49:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.887 uVs 14:49:16 Integrated Voltage Measurement... 14:49:25 Voltage Offset Correction: v_off_ini = 568.740 uV, v_off_fin = 569.127 uV 14:49:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.255 uVs 14:49:25 Integrated Voltage Measurement... 14:49:34 Voltage Offset Correction: v_off_ini = 549.391 uV, v_off_fin = 548.581 uV 14:49:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.420 uVs 14:49:34 Integrated Voltage Measurement... 14:49:43 Voltage Offset Correction: v_off_ini = 556.542 uV, v_off_fin = 563.844 uV 14:49:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.858 uVs 14:49:47 I1X Average and RMS of Measurements VT = -39.700 +- 1.071 uVs I1X = 7.940 +- 0.214 uTm 14:49:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:49:54 Integrated Voltage Measurement... 14:50:03 Voltage Offset Correction: v_off_ini = 554.325 uV, v_off_fin = 542.758 uV 14:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.661 uVs 14:50:03 Integrated Voltage Measurement... 14:50:12 Voltage Offset Correction: v_off_ini = 562.825 uV, v_off_fin = 558.761 uV 14:50:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.398 uVs 14:50:12 Integrated Voltage Measurement... 14:50:21 Voltage Offset Correction: v_off_ini = 558.211 uV, v_off_fin = 550.349 uV 14:50:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.397 uVs 14:50:21 Integrated Voltage Measurement... 14:50:30 Voltage Offset Correction: v_off_ini = 558.571 uV, v_off_fin = 575.471 uV 14:50:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.126 uVs 14:50:30 Integrated Voltage Measurement... 14:50:39 Voltage Offset Correction: v_off_ini = 557.597 uV, v_off_fin = 544.452 uV 14:50:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.798 uVs 14:50:39 Integrated Voltage Measurement... 14:50:48 Voltage Offset Correction: v_off_ini = 559.855 uV, v_off_fin = 568.276 uV 14:50:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.951 uVs 14:50:52 I1Y Average and RMS of Measurements VT = -275.388 +- 5.581 uVs I1Y = -55.078 +- 1.116 uTm 14:50:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:51:00 Integrated Voltage Measurement... 14:51:09 Voltage Offset Correction: v_off_ini = 564.941 uV, v_off_fin = 560.277 uV 14:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.813 uVs 14:51:09 Integrated Voltage Measurement... 14:51:18 Voltage Offset Correction: v_off_ini = 573.264 uV, v_off_fin = 591.676 uV 14:51:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 8.295 uVs 14:51:18 Integrated Voltage Measurement... 14:51:27 Voltage Offset Correction: v_off_ini = 588.688 uV, v_off_fin = 566.852 uV 14:51:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.919 uVs 14:51:27 Integrated Voltage Measurement... 14:51:36 Voltage Offset Correction: v_off_ini = 573.219 uV, v_off_fin = 588.094 uV 14:51:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 32.764 uVs 14:51:36 Integrated Voltage Measurement... 14:51:45 Voltage Offset Correction: v_off_ini = 585.731 uV, v_off_fin = 571.789 uV 14:51:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.537 uVs 14:51:45 Integrated Voltage Measurement... 14:51:54 Voltage Offset Correction: v_off_ini = 581.166 uV, v_off_fin = 580.652 uV 14:51:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 23.900 uVs 14:51:57 I2X Average and RMS of Measurements VT = -32.538 +- 6.270 uVs I2X = 2.994 +- 0.577 uTm^2 14:52:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:52:04 Integrated Voltage Measurement... 14:52:13 Voltage Offset Correction: v_off_ini = 546.420 uV, v_off_fin = 559.159 uV 14:52:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.280 uVs 14:52:13 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 547.775 uV, v_off_fin = 553.846 uV 14:52:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.615 uVs 14:52:22 Integrated Voltage Measurement... 14:52:31 Voltage Offset Correction: v_off_ini = 559.160 uV, v_off_fin = 557.670 uV 14:52:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -485.083 uVs 14:52:31 Integrated Voltage Measurement... 14:52:40 Voltage Offset Correction: v_off_ini = 555.654 uV, v_off_fin = 570.568 uV 14:52:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 472.074 uVs 14:52:40 Integrated Voltage Measurement... 14:52:49 Voltage Offset Correction: v_off_ini = 555.348 uV, v_off_fin = 557.268 uV 14:52:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.715 uVs 14:52:49 Integrated Voltage Measurement... 14:52:58 Voltage Offset Correction: v_off_ini = 547.498 uV, v_off_fin = 544.865 uV 14:52:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 480.147 uVs 14:53:01 I2Y Average and RMS of Measurements VT = -479.652 +- 0.980 uVs I2Y = -44.128 +- 0.090 uTm^2 14:53:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:53:10 Integrated Voltage Measurement... 14:53:19 Voltage Offset Correction: v_off_ini = 564.806 uV, v_off_fin = 557.180 uV 14:53:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.282 uVs 14:53:19 Integrated Voltage Measurement... 14:53:28 Voltage Offset Correction: v_off_ini = 560.081 uV, v_off_fin = 560.303 uV 14:53:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 54.019 uVs 14:53:28 Integrated Voltage Measurement... 14:53:37 Voltage Offset Correction: v_off_ini = 553.449 uV, v_off_fin = 559.938 uV 14:53:37 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -36.017 uVs 14:53:37 Integrated Voltage Measurement... 14:53:46 Voltage Offset Correction: v_off_ini = 562.110 uV, v_off_fin = 582.514 uV 14:53:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.093 uVs 14:53:46 Integrated Voltage Measurement... 14:53:55 Voltage Offset Correction: v_off_ini = 585.285 uV, v_off_fin = 576.190 uV 14:53:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.032 uVs 14:53:55 Integrated Voltage Measurement... 14:54:04 Voltage Offset Correction: v_off_ini = 568.685 uV, v_off_fin = 573.531 uV 14:54:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.822 uVs 14:54:08 I1X Average and RMS of Measurements VT = -50.211 +- 5.283 uVs I1X = 10.043 +- 1.056 uTm 14:54:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:54:15 Integrated Voltage Measurement... 14:54:24 Voltage Offset Correction: v_off_ini = 559.832 uV, v_off_fin = 547.257 uV 14:54:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.568 uVs 14:54:24 Integrated Voltage Measurement... 14:54:33 Voltage Offset Correction: v_off_ini = 554.499 uV, v_off_fin = 573.633 uV 14:54:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.268 uVs 14:54:33 Integrated Voltage Measurement... 14:54:42 Voltage Offset Correction: v_off_ini = 566.858 uV, v_off_fin = 547.096 uV 14:54:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -286.549 uVs 14:54:42 Integrated Voltage Measurement... 14:54:51 Voltage Offset Correction: v_off_ini = 557.692 uV, v_off_fin = 569.081 uV 14:54:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.072 uVs 14:54:51 Integrated Voltage Measurement... 14:55:00 Voltage Offset Correction: v_off_ini = 539.127 uV, v_off_fin = 540.297 uV 14:55:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.285 uVs 14:55:00 Integrated Voltage Measurement... 14:55:09 Voltage Offset Correction: v_off_ini = 548.170 uV, v_off_fin = 569.326 uV 14:55:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.988 uVs 14:55:13 I1Y Average and RMS of Measurements VT = -272.955 +- 3.411 uVs I1Y = -54.591 +- 0.682 uTm 14:55:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:55:21 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = 546.390 uV, v_off_fin = 555.625 uV 14:55:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -27.800 uVs 14:55:30 Integrated Voltage Measurement... 14:55:39 Voltage Offset Correction: v_off_ini = 542.521 uV, v_off_fin = 561.236 uV 14:55:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.692 uVs 14:55:39 Integrated Voltage Measurement... 14:55:48 Voltage Offset Correction: v_off_ini = 555.545 uV, v_off_fin = 547.399 uV 14:55:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.089 uVs 14:55:48 Integrated Voltage Measurement... 14:55:57 Voltage Offset Correction: v_off_ini = 560.496 uV, v_off_fin = 558.420 uV 14:55:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 31.162 uVs 14:55:57 Integrated Voltage Measurement... 14:56:06 Voltage Offset Correction: v_off_ini = 537.815 uV, v_off_fin = 542.839 uV 14:56:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.490 uVs 14:56:06 Integrated Voltage Measurement... 14:56:15 Voltage Offset Correction: v_off_ini = 561.764 uV, v_off_fin = 573.184 uV 14:56:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.729 uVs 14:56:17 I2X Average and RMS of Measurements VT = -33.660 +- 6.580 uVs I2X = 3.097 +- 0.605 uTm^2 14:56:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:56:25 Integrated Voltage Measurement... 14:56:34 Voltage Offset Correction: v_off_ini = 570.876 uV, v_off_fin = 565.969 uV 14:56:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.497 uVs 14:56:34 Integrated Voltage Measurement... 14:56:43 Voltage Offset Correction: v_off_ini = 562.412 uV, v_off_fin = 560.914 uV 14:56:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.952 uVs 14:56:43 Integrated Voltage Measurement... 14:56:52 Voltage Offset Correction: v_off_ini = 565.628 uV, v_off_fin = 566.046 uV 14:56:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.307 uVs 14:56:52 Integrated Voltage Measurement... 14:57:01 Voltage Offset Correction: v_off_ini = 562.267 uV, v_off_fin = 562.111 uV 14:57:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 483.786 uVs 14:57:01 Integrated Voltage Measurement... 14:57:10 Voltage Offset Correction: v_off_ini = 561.727 uV, v_off_fin = 560.616 uV 14:57:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -478.808 uVs 14:57:10 Integrated Voltage Measurement... 14:57:19 Voltage Offset Correction: v_off_ini = 562.597 uV, v_off_fin = 572.906 uV 14:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.977 uVs 14:57:21 I2Y Average and RMS of Measurements VT = -472.388 +- 8.318 uVs I2Y = -43.460 +- 0.765 uTm^2 14:57:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:30 Integrated Voltage Measurement... 14:57:39 Voltage Offset Correction: v_off_ini = 573.334 uV, v_off_fin = 556.871 uV 14:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.659 uVs 14:57:39 Integrated Voltage Measurement... 14:57:48 Voltage Offset Correction: v_off_ini = 572.607 uV, v_off_fin = 578.888 uV 14:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.769 uVs 14:57:48 Integrated Voltage Measurement... 14:57:57 Voltage Offset Correction: v_off_ini = 559.145 uV, v_off_fin = 576.771 uV 14:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.368 uVs 14:57:57 Integrated Voltage Measurement... 14:58:06 Voltage Offset Correction: v_off_ini = 576.521 uV, v_off_fin = 582.510 uV 14:58:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.287 uVs 14:58:06 Integrated Voltage Measurement... 14:58:15 Voltage Offset Correction: v_off_ini = 579.004 uV, v_off_fin = 562.472 uV 14:58:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.994 uVs 14:58:15 Integrated Voltage Measurement... 14:58:24 Voltage Offset Correction: v_off_ini = 563.550 uV, v_off_fin = 579.939 uV 14:58:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.703 uVs 14:58:29 I1X Average and RMS of Measurements VT = -61.130 +- 3.849 uVs I1X = 12.226 +- 0.770 uTm 14:58:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:35 Integrated Voltage Measurement... 14:58:44 Voltage Offset Correction: v_off_ini = 586.607 uV, v_off_fin = 568.813 uV 14:58:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.123 uVs 14:58:44 Integrated Voltage Measurement... 14:58:53 Voltage Offset Correction: v_off_ini = 584.486 uV, v_off_fin = 585.073 uV 14:58:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.245 uVs 14:58:53 Integrated Voltage Measurement... 14:59:02 Voltage Offset Correction: v_off_ini = 583.804 uV, v_off_fin = 571.582 uV 14:59:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.524 uVs 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 573.616 uV, v_off_fin = 586.344 uV 14:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.896 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 565.334 uV, v_off_fin = 570.798 uV 14:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.040 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 575.241 uV, v_off_fin = 591.205 uV 14:59:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.478 uVs 14:59:33 I1Y Average and RMS of Measurements VT = -251.384 +- 1.665 uVs I1Y = -50.277 +- 0.333 uTm 14:59:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:41 Integrated Voltage Measurement... 14:59:50 Voltage Offset Correction: v_off_ini = 582.387 uV, v_off_fin = 573.460 uV 14:59:50 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -45.043 uVs 14:59:50 Integrated Voltage Measurement... 14:59:59 Voltage Offset Correction: v_off_ini = 579.020 uV, v_off_fin = 577.668 uV 14:59:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 40.203 uVs 14:59:59 Integrated Voltage Measurement... 15:00:08 Voltage Offset Correction: v_off_ini = 571.996 uV, v_off_fin = 570.187 uV 15:00:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -39.494 uVs 15:00:08 Integrated Voltage Measurement... 15:00:17 Voltage Offset Correction: v_off_ini = 585.411 uV, v_off_fin = 585.804 uV 15:00:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.992 uVs 15:00:17 Integrated Voltage Measurement... 15:00:26 Voltage Offset Correction: v_off_ini = 574.539 uV, v_off_fin = 574.808 uV 15:00:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.258 uVs 15:00:26 Integrated Voltage Measurement... 15:00:35 Voltage Offset Correction: v_off_ini = 569.683 uV, v_off_fin = 585.850 uV 15:00:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.832 uVs 15:00:38 I2X Average and RMS of Measurements VT = -48.137 +- 12.195 uVs I2X = 4.429 +- 1.122 uTm^2 15:00:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:45 Integrated Voltage Measurement... 15:00:54 Voltage Offset Correction: v_off_ini = 589.945 uV, v_off_fin = 589.712 uV 15:00:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -481.111 uVs 15:00:54 Integrated Voltage Measurement... 15:01:03 Voltage Offset Correction: v_off_ini = 591.814 uV, v_off_fin = 582.782 uV 15:01:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 469.732 uVs 15:01:03 Integrated Voltage Measurement... 15:01:12 Voltage Offset Correction: v_off_ini = 573.256 uV, v_off_fin = 575.448 uV 15:01:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -448.403 uVs 15:01:13 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 586.504 uV, v_off_fin = 598.910 uV 15:01:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 479.334 uVs 15:01:22 Integrated Voltage Measurement... 15:01:31 Voltage Offset Correction: v_off_ini = 583.418 uV, v_off_fin = 589.140 uV 15:01:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -464.271 uVs 15:01:31 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = 598.346 uV, v_off_fin = 592.342 uV 15:01:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 458.775 uVs 15:01:42 I2Y Average and RMS of Measurements VT = -466.938 +- 6.075 uVs I2Y = -42.958 +- 0.559 uTm^2 15:01:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:01:51 Integrated Voltage Measurement... 15:02:00 Voltage Offset Correction: v_off_ini = 586.092 uV, v_off_fin = 585.783 uV 15:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.801 uVs 15:02:00 Integrated Voltage Measurement... 15:02:09 Voltage Offset Correction: v_off_ini = 579.552 uV, v_off_fin = 591.330 uV 15:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.952 uVs 15:02:09 Integrated Voltage Measurement... 15:02:18 Voltage Offset Correction: v_off_ini = 585.817 uV, v_off_fin = 580.574 uV 15:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.511 uVs 15:02:18 Integrated Voltage Measurement... 15:02:27 Voltage Offset Correction: v_off_ini = 588.247 uV, v_off_fin = 599.046 uV 15:02:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.573 uVs 15:02:27 Integrated Voltage Measurement... 15:02:36 Voltage Offset Correction: v_off_ini = 587.965 uV, v_off_fin = 584.069 uV 15:02:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.663 uVs 15:02:36 Integrated Voltage Measurement... 15:02:45 Voltage Offset Correction: v_off_ini = 592.672 uV, v_off_fin = 595.730 uV 15:02:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.180 uVs 15:02:49 I1X Average and RMS of Measurements VT = -67.447 +- 4.137 uVs I1X = 13.490 +- 0.828 uTm 15:02:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:02:56 Integrated Voltage Measurement... 15:03:05 Voltage Offset Correction: v_off_ini = 573.315 uV, v_off_fin = 563.023 uV 15:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.479 uVs 15:03:05 Integrated Voltage Measurement... 15:03:14 Voltage Offset Correction: v_off_ini = 576.808 uV, v_off_fin = 586.907 uV 15:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.334 uVs 15:03:14 Integrated Voltage Measurement... 15:03:23 Voltage Offset Correction: v_off_ini = 575.012 uV, v_off_fin = 565.825 uV 15:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.593 uVs 15:03:23 Integrated Voltage Measurement... 15:03:32 Voltage Offset Correction: v_off_ini = 575.452 uV, v_off_fin = 577.066 uV 15:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.632 uVs 15:03:32 Integrated Voltage Measurement... 15:03:41 Voltage Offset Correction: v_off_ini = 572.477 uV, v_off_fin = 564.904 uV 15:03:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.610 uVs 15:03:41 Integrated Voltage Measurement... 15:03:50 Voltage Offset Correction: v_off_ini = 567.411 uV, v_off_fin = 590.080 uV 15:03:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.014 uVs 15:03:54 I1Y Average and RMS of Measurements VT = -241.277 +- 0.803 uVs I1Y = -48.255 +- 0.161 uTm 15:03:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:04:02 Integrated Voltage Measurement... 15:04:11 Voltage Offset Correction: v_off_ini = 576.321 uV, v_off_fin = 574.564 uV 15:04:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -63.345 uVs 15:04:11 Integrated Voltage Measurement... 15:04:20 Voltage Offset Correction: v_off_ini = 572.652 uV, v_off_fin = 575.115 uV 15:04:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.801 uVs 15:04:20 Integrated Voltage Measurement... 15:04:29 Voltage Offset Correction: v_off_ini = 568.978 uV, v_off_fin = 558.251 uV 15:04:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.688 uVs 15:04:29 Integrated Voltage Measurement... 15:04:38 Voltage Offset Correction: v_off_ini = 562.411 uV, v_off_fin = 579.876 uV 15:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.952 uVs 15:04:38 Integrated Voltage Measurement... 15:04:47 Voltage Offset Correction: v_off_ini = 572.873 uV, v_off_fin = 561.044 uV 15:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.855 uVs 15:04:47 Integrated Voltage Measurement... 15:04:56 Voltage Offset Correction: v_off_ini = 568.166 uV, v_off_fin = 572.431 uV 15:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.145 uVs 15:04:58 I2X Average and RMS of Measurements VT = -62.131 +- 4.737 uVs I2X = 5.716 +- 0.436 uTm^2 15:05:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:05:06 Integrated Voltage Measurement... 15:05:15 Voltage Offset Correction: v_off_ini = 563.997 uV, v_off_fin = 549.165 uV 15:05:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.036 uVs 15:05:15 Integrated Voltage Measurement... 15:05:24 Voltage Offset Correction: v_off_ini = 548.826 uV, v_off_fin = 547.917 uV 15:05:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.452 uVs 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 551.448 uV, v_off_fin = 559.615 uV 15:05:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -443.987 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 553.247 uV, v_off_fin = 549.035 uV 15:05:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.979 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = 547.990 uV, v_off_fin = 539.454 uV 15:05:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.078 uVs 15:05:51 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = 558.151 uV, v_off_fin = 552.528 uV 15:06:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.033 uVs 15:06:03 I2Y Average and RMS of Measurements VT = -444.594 +- 7.574 uVs I2Y = -40.903 +- 0.697 uTm^2 15:06:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:06:12 Integrated Voltage Measurement... 15:06:21 Voltage Offset Correction: v_off_ini = 562.056 uV, v_off_fin = 552.312 uV 15:06:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.001 uVs 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = 556.628 uV, v_off_fin = 550.984 uV 15:06:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.385 uVs 15:06:30 Integrated Voltage Measurement... 15:06:39 Voltage Offset Correction: v_off_ini = 541.605 uV, v_off_fin = 547.443 uV 15:06:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.430 uVs 15:06:39 Integrated Voltage Measurement... 15:06:48 Voltage Offset Correction: v_off_ini = 545.903 uV, v_off_fin = 550.521 uV 15:06:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.496 uVs 15:06:48 Integrated Voltage Measurement... 15:06:57 Voltage Offset Correction: v_off_ini = 548.501 uV, v_off_fin = 535.319 uV 15:06:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.515 uVs 15:06:57 Integrated Voltage Measurement... 15:07:06 Voltage Offset Correction: v_off_ini = 550.693 uV, v_off_fin = 545.623 uV 15:07:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.756 uVs 15:07:10 I1X Average and RMS of Measurements VT = -83.597 +- 10.829 uVs I1X = 16.719 +- 2.166 uTm 15:07:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:07:17 Integrated Voltage Measurement... 15:07:26 Voltage Offset Correction: v_off_ini = 545.076 uV, v_off_fin = 536.055 uV 15:07:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -210.703 uVs 15:07:26 Integrated Voltage Measurement... 15:07:35 Voltage Offset Correction: v_off_ini = 543.709 uV, v_off_fin = 549.656 uV 15:07:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.728 uVs 15:07:35 Integrated Voltage Measurement... 15:07:44 Voltage Offset Correction: v_off_ini = 547.313 uV, v_off_fin = 538.878 uV 15:07:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.458 uVs 15:07:44 Integrated Voltage Measurement... 15:07:53 Voltage Offset Correction: v_off_ini = 544.530 uV, v_off_fin = 565.625 uV 15:07:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.801 uVs 15:07:53 Integrated Voltage Measurement... 15:08:02 Voltage Offset Correction: v_off_ini = 558.276 uV, v_off_fin = 554.977 uV 15:08:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.426 uVs 15:08:02 Integrated Voltage Measurement... 15:08:11 Voltage Offset Correction: v_off_ini = 554.613 uV, v_off_fin = 565.644 uV 15:08:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.469 uVs 15:08:15 I1Y Average and RMS of Measurements VT = -225.431 +- 3.719 uVs I1Y = -45.087 +- 0.743 uTm 15:08:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:08:23 Integrated Voltage Measurement... 15:08:32 Voltage Offset Correction: v_off_ini = 544.799 uV, v_off_fin = 553.539 uV 15:08:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -65.257 uVs 15:08:32 Integrated Voltage Measurement... 15:08:41 Voltage Offset Correction: v_off_ini = 548.727 uV, v_off_fin = 564.612 uV 15:08:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.132 uVs 15:08:41 Integrated Voltage Measurement... 15:08:50 Voltage Offset Correction: v_off_ini = 550.496 uV, v_off_fin = 546.537 uV 15:08:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.553 uVs 15:08:50 Integrated Voltage Measurement... 15:08:59 Voltage Offset Correction: v_off_ini = 555.076 uV, v_off_fin = 562.311 uV 15:08:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.823 uVs 15:08:59 Integrated Voltage Measurement... 15:09:08 Voltage Offset Correction: v_off_ini = 555.548 uV, v_off_fin = 547.570 uV 15:09:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.963 uVs 15:09:08 Integrated Voltage Measurement... 15:09:17 Voltage Offset Correction: v_off_ini = 566.075 uV, v_off_fin = 572.153 uV 15:09:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.122 uVs 15:09:19 I2X Average and RMS of Measurements VT = -70.142 +- 2.205 uVs I2X = 6.453 +- 0.203 uTm^2 15:09:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = 552.022 uV, v_off_fin = 552.857 uV 15:09:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.671 uVs 15:09:36 Integrated Voltage Measurement... 15:09:45 Voltage Offset Correction: v_off_ini = 545.159 uV, v_off_fin = 558.487 uV 15:09:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.393 uVs 15:09:45 Integrated Voltage Measurement... 15:09:54 Voltage Offset Correction: v_off_ini = 558.553 uV, v_off_fin = 545.468 uV 15:09:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.875 uVs 15:09:54 Integrated Voltage Measurement... 15:10:03 Voltage Offset Correction: v_off_ini = 552.019 uV, v_off_fin = 558.880 uV 15:10:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 417.582 uVs 15:10:03 Integrated Voltage Measurement... 15:10:12 Voltage Offset Correction: v_off_ini = 557.544 uV, v_off_fin = 549.860 uV 15:10:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -422.324 uVs 15:10:12 Integrated Voltage Measurement... 15:10:21 Voltage Offset Correction: v_off_ini = 558.912 uV, v_off_fin = 553.776 uV 15:10:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.445 uVs 15:10:24 I2Y Average and RMS of Measurements VT = -420.382 +- 1.680 uVs I2Y = -38.675 +- 0.155 uTm^2 15:10:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:10:36 Integrated Voltage Measurement... 15:10:44 Voltage Offset Correction: v_off_ini = 564.365 uV, v_off_fin = 546.904 uV 15:10:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -26.752 uVs 15:10:45 Integrated Voltage Measurement... 15:10:53 Voltage Offset Correction: v_off_ini = 561.882 uV, v_off_fin = 563.822 uV 15:10:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.357 uVs 15:10:54 Integrated Voltage Measurement... 15:11:03 Voltage Offset Correction: v_off_ini = 562.422 uV, v_off_fin = 559.968 uV 15:11:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.650 uVs 15:11:03 Integrated Voltage Measurement... 15:11:12 Voltage Offset Correction: v_off_ini = 552.245 uV, v_off_fin = 566.894 uV 15:11:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.899 uVs 15:11:12 Integrated Voltage Measurement... 15:11:21 Voltage Offset Correction: v_off_ini = 555.475 uV, v_off_fin = 545.569 uV 15:11:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.861 uVs 15:11:21 Integrated Voltage Measurement... 15:11:30 Voltage Offset Correction: v_off_ini = 546.840 uV, v_off_fin = 555.445 uV 15:11:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.035 uVs 15:11:34 I1X Average and RMS of Measurements VT = -33.926 +- 7.692 uVs I1X = 6.785 +- 1.538 uTm 15:11:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:11:41 Integrated Voltage Measurement... 15:11:50 Voltage Offset Correction: v_off_ini = 551.959 uV, v_off_fin = 552.013 uV 15:11:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.220 uVs 15:11:50 Integrated Voltage Measurement... 15:11:59 Voltage Offset Correction: v_off_ini = 557.238 uV, v_off_fin = 564.257 uV 15:11:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.718 uVs 15:11:59 Integrated Voltage Measurement... 15:12:08 Voltage Offset Correction: v_off_ini = 543.598 uV, v_off_fin = 542.636 uV 15:12:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.394 uVs 15:12:08 Integrated Voltage Measurement... 15:12:17 Voltage Offset Correction: v_off_ini = 548.350 uV, v_off_fin = 566.434 uV 15:12:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.062 uVs 15:12:17 Integrated Voltage Measurement... 15:12:26 Voltage Offset Correction: v_off_ini = 569.887 uV, v_off_fin = 549.029 uV 15:12:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.194 uVs 15:12:26 Integrated Voltage Measurement... 15:12:35 Voltage Offset Correction: v_off_ini = 547.841 uV, v_off_fin = 556.269 uV 15:12:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.468 uVs 15:12:39 I1Y Average and RMS of Measurements VT = -246.176 +- 2.526 uVs I1Y = -49.237 +- 0.504 uTm 15:12:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:12:44 Integrated Voltage Measurement... 15:12:53 Voltage Offset Correction: v_off_ini = 536.572 uV, v_off_fin = 534.110 uV 15:12:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.028 uVs 15:12:53 Integrated Voltage Measurement... 15:13:02 Voltage Offset Correction: v_off_ini = 553.071 uV, v_off_fin = 549.093 uV 15:13:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.059 uVs 15:13:02 Integrated Voltage Measurement... 15:13:11 Voltage Offset Correction: v_off_ini = 529.388 uV, v_off_fin = 539.847 uV 15:13:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.231 uVs 15:13:11 Integrated Voltage Measurement... 15:13:20 Voltage Offset Correction: v_off_ini = 547.305 uV, v_off_fin = 555.140 uV 15:13:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.987 uVs 15:13:20 Integrated Voltage Measurement... 15:13:29 Voltage Offset Correction: v_off_ini = 570.186 uV, v_off_fin = 543.315 uV 15:13:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.059 uVs 15:13:29 Integrated Voltage Measurement... 15:13:38 Voltage Offset Correction: v_off_ini = 542.903 uV, v_off_fin = 569.827 uV 15:13:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.610 uVs 15:13:40 I2X Average and RMS of Measurements VT = -30.662 +- 8.989 uVs I2X = 2.821 +- 0.827 uTm^2 15:13:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 543.486 uV, v_off_fin = 543.943 uV 15:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -451.834 uVs 15:13:55 Integrated Voltage Measurement... 15:14:04 Voltage Offset Correction: v_off_ini = 546.122 uV, v_off_fin = 537.721 uV 15:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 450.614 uVs 15:14:04 Integrated Voltage Measurement... 15:14:13 Voltage Offset Correction: v_off_ini = 550.864 uV, v_off_fin = 550.790 uV 15:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.635 uVs 15:14:13 Integrated Voltage Measurement... 15:14:22 Voltage Offset Correction: v_off_ini = 542.304 uV, v_off_fin = 556.180 uV 15:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 442.350 uVs 15:14:22 Integrated Voltage Measurement... 15:14:31 Voltage Offset Correction: v_off_ini = 549.816 uV, v_off_fin = 558.412 uV 15:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.870 uVs 15:14:31 Integrated Voltage Measurement... 15:14:40 Voltage Offset Correction: v_off_ini = 544.026 uV, v_off_fin = 540.044 uV 15:14:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 440.416 uVs 15:14:42 I2Y Average and RMS of Measurements VT = -449.287 +- 3.041 uVs I2Y = -41.334 +- 0.280 uTm^2 15:14:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:14:51 Integrated Voltage Measurement... 15:14:59 Voltage Offset Correction: v_off_ini = 560.571 uV, v_off_fin = 548.729 uV 15:15:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.006 uVs 15:15:00 Integrated Voltage Measurement... 15:15:08 Voltage Offset Correction: v_off_ini = 540.705 uV, v_off_fin = 539.182 uV 15:15:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.920 uVs 15:15:09 Integrated Voltage Measurement... 15:15:18 Voltage Offset Correction: v_off_ini = 549.669 uV, v_off_fin = 537.928 uV 15:15:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -61.215 uVs 15:15:18 Integrated Voltage Measurement... 15:15:27 Voltage Offset Correction: v_off_ini = 551.410 uV, v_off_fin = 548.114 uV 15:15:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 49.927 uVs 15:15:27 Integrated Voltage Measurement... 15:15:36 Voltage Offset Correction: v_off_ini = 542.888 uV, v_off_fin = 548.169 uV 15:15:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.731 uVs 15:15:36 Integrated Voltage Measurement... 15:15:45 Voltage Offset Correction: v_off_ini = 559.743 uV, v_off_fin = 557.169 uV 15:15:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.765 uVs 15:15:49 I1X Average and RMS of Measurements VT = -46.260 +- 7.298 uVs I1X = 9.253 +- 1.460 uTm 15:15:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:15:56 Integrated Voltage Measurement... 15:16:05 Voltage Offset Correction: v_off_ini = 539.172 uV, v_off_fin = 532.257 uV 15:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.767 uVs 15:16:05 Integrated Voltage Measurement... 15:16:14 Voltage Offset Correction: v_off_ini = 556.870 uV, v_off_fin = 555.993 uV 15:16:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.332 uVs 15:16:14 Integrated Voltage Measurement... 15:16:23 Voltage Offset Correction: v_off_ini = 545.487 uV, v_off_fin = 530.241 uV 15:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.376 uVs 15:16:23 Integrated Voltage Measurement... 15:16:32 Voltage Offset Correction: v_off_ini = 533.443 uV, v_off_fin = 535.880 uV 15:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.782 uVs 15:16:32 Integrated Voltage Measurement... 15:16:41 Voltage Offset Correction: v_off_ini = 533.233 uV, v_off_fin = 527.094 uV 15:16:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.838 uVs 15:16:41 Integrated Voltage Measurement... 15:16:50 Voltage Offset Correction: v_off_ini = 550.529 uV, v_off_fin = 555.804 uV 15:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.062 uVs 15:16:54 I1Y Average and RMS of Measurements VT = -246.860 +- 2.417 uVs I1Y = -49.372 +- 0.483 uTm 15:16:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:16:59 Integrated Voltage Measurement... 15:17:08 Voltage Offset Correction: v_off_ini = 540.358 uV, v_off_fin = 540.510 uV 15:17:08 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -46.462 uVs 15:17:08 Integrated Voltage Measurement... 15:17:17 Voltage Offset Correction: v_off_ini = 541.708 uV, v_off_fin = 559.804 uV 15:17:17 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 43.071 uVs 15:17:17 Integrated Voltage Measurement... 15:17:26 Voltage Offset Correction: v_off_ini = 533.261 uV, v_off_fin = 535.018 uV 15:17:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.699 uVs 15:17:26 Integrated Voltage Measurement... 15:17:35 Voltage Offset Correction: v_off_ini = 538.402 uV, v_off_fin = 544.883 uV 15:17:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 25.309 uVs 15:17:35 Integrated Voltage Measurement... 15:17:44 Voltage Offset Correction: v_off_ini = 540.927 uV, v_off_fin = 523.723 uV 15:17:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -36.099 uVs 15:17:44 Integrated Voltage Measurement... 15:17:53 Voltage Offset Correction: v_off_ini = 537.806 uV, v_off_fin = 548.259 uV 15:17:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.955 uVs 15:17:56 I2X Average and RMS of Measurements VT = -38.766 +- 5.755 uVs I2X = 3.567 +- 0.529 uTm^2 15:17:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:18:01 Integrated Voltage Measurement... 15:18:10 Voltage Offset Correction: v_off_ini = 540.052 uV, v_off_fin = 538.571 uV 15:18:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -449.875 uVs 15:18:10 Integrated Voltage Measurement... 15:18:19 Voltage Offset Correction: v_off_ini = 538.794 uV, v_off_fin = 535.426 uV 15:18:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 456.078 uVs 15:18:19 Integrated Voltage Measurement... 15:18:28 Voltage Offset Correction: v_off_ini = 557.645 uV, v_off_fin = 549.892 uV 15:18:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.406 uVs 15:18:28 Integrated Voltage Measurement... 15:18:37 Voltage Offset Correction: v_off_ini = 547.927 uV, v_off_fin = 545.611 uV 15:18:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.888 uVs 15:18:37 Integrated Voltage Measurement... 15:18:46 Voltage Offset Correction: v_off_ini = 545.192 uV, v_off_fin = 529.556 uV 15:18:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -438.983 uVs 15:18:46 Integrated Voltage Measurement... 15:18:55 Voltage Offset Correction: v_off_ini = 537.614 uV, v_off_fin = 543.995 uV 15:18:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 451.815 uVs 15:18:57 I2Y Average and RMS of Measurements VT = -451.174 +- 4.179 uVs I2Y = -41.508 +- 0.384 uTm^2 15:19:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:06 Integrated Voltage Measurement... 15:19:15 Voltage Offset Correction: v_off_ini = 563.761 uV, v_off_fin = 546.731 uV 15:19:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.976 uVs 15:19:15 Integrated Voltage Measurement... 15:19:24 Voltage Offset Correction: v_off_ini = 545.015 uV, v_off_fin = 556.336 uV 15:19:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.430 uVs 15:19:24 Integrated Voltage Measurement... 15:19:33 Voltage Offset Correction: v_off_ini = 548.511 uV, v_off_fin = 547.459 uV 15:19:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.971 uVs 15:19:33 Integrated Voltage Measurement... 15:19:42 Voltage Offset Correction: v_off_ini = 548.751 uV, v_off_fin = 548.374 uV 15:19:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.352 uVs 15:19:42 Integrated Voltage Measurement... 15:19:51 Voltage Offset Correction: v_off_ini = 549.490 uV, v_off_fin = 545.692 uV 15:19:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.158 uVs 15:19:51 Integrated Voltage Measurement... 15:20:00 Voltage Offset Correction: v_off_ini = 562.303 uV, v_off_fin = 548.385 uV 15:20:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.695 uVs 15:20:04 I1X Average and RMS of Measurements VT = -59.764 +- 5.608 uVs I1X = 11.953 +- 1.122 uTm 15:20:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:11 Integrated Voltage Measurement... 15:20:20 Voltage Offset Correction: v_off_ini = 550.060 uV, v_off_fin = 539.823 uV 15:20:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.233 uVs 15:20:20 Integrated Voltage Measurement... 15:20:29 Voltage Offset Correction: v_off_ini = 545.741 uV, v_off_fin = 546.191 uV 15:20:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.578 uVs 15:20:29 Integrated Voltage Measurement... 15:20:38 Voltage Offset Correction: v_off_ini = 539.145 uV, v_off_fin = 533.444 uV 15:20:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.435 uVs 15:20:38 Integrated Voltage Measurement... 15:20:47 Voltage Offset Correction: v_off_ini = 530.716 uV, v_off_fin = 549.443 uV 15:20:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.797 uVs 15:20:47 Integrated Voltage Measurement... 15:20:56 Voltage Offset Correction: v_off_ini = 542.607 uV, v_off_fin = 533.979 uV 15:20:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.892 uVs 15:20:56 Integrated Voltage Measurement... 15:21:05 Voltage Offset Correction: v_off_ini = 522.504 uV, v_off_fin = 556.275 uV 15:21:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.338 uVs 15:21:09 I1Y Average and RMS of Measurements VT = -251.712 +- 2.699 uVs I1Y = -50.344 +- 0.540 uTm 15:21:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:14 Integrated Voltage Measurement... 15:21:23 Voltage Offset Correction: v_off_ini = 556.030 uV, v_off_fin = 540.960 uV 15:21:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.453 uVs 15:21:23 Integrated Voltage Measurement... 15:21:32 Voltage Offset Correction: v_off_ini = 543.612 uV, v_off_fin = 557.751 uV 15:21:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 42.343 uVs 15:21:32 Integrated Voltage Measurement... 15:21:41 Voltage Offset Correction: v_off_ini = 535.742 uV, v_off_fin = 536.821 uV 15:21:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.513 uVs 15:21:41 Integrated Voltage Measurement... 15:21:50 Voltage Offset Correction: v_off_ini = 549.386 uV, v_off_fin = 557.298 uV 15:21:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.239 uVs 15:21:50 Integrated Voltage Measurement... 15:21:59 Voltage Offset Correction: v_off_ini = 559.487 uV, v_off_fin = 538.707 uV 15:21:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.709 uVs 15:21:59 Integrated Voltage Measurement... 15:22:08 Voltage Offset Correction: v_off_ini = 555.042 uV, v_off_fin = 552.315 uV 15:22:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.916 uVs 15:22:11 I2X Average and RMS of Measurements VT = -50.695 +- 3.336 uVs I2X = 4.664 +- 0.307 uTm^2 15:22:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:16 Integrated Voltage Measurement... 15:22:25 Voltage Offset Correction: v_off_ini = 559.098 uV, v_off_fin = 555.312 uV 15:22:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.011 uVs 15:22:25 Integrated Voltage Measurement... 15:22:34 Voltage Offset Correction: v_off_ini = 553.681 uV, v_off_fin = 541.288 uV 15:22:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.029 uVs 15:22:34 Integrated Voltage Measurement... 15:22:43 Voltage Offset Correction: v_off_ini = 571.215 uV, v_off_fin = 553.849 uV 15:22:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -460.874 uVs 15:22:43 Integrated Voltage Measurement... 15:22:52 Voltage Offset Correction: v_off_ini = 559.578 uV, v_off_fin = 553.138 uV 15:22:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 449.614 uVs 15:22:52 Integrated Voltage Measurement... 15:23:01 Voltage Offset Correction: v_off_ini = 553.166 uV, v_off_fin = 549.508 uV 15:23:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -475.736 uVs 15:23:01 Integrated Voltage Measurement... 15:23:10 Voltage Offset Correction: v_off_ini = 550.863 uV, v_off_fin = 567.341 uV 15:23:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 464.271 uVs 15:23:12 I2Y Average and RMS of Measurements VT = -456.922 +- 10.066 uVs I2Y = -42.037 +- 0.926 uTm^2 15:23:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:23:21 Integrated Voltage Measurement... 15:23:30 Voltage Offset Correction: v_off_ini = 546.037 uV, v_off_fin = 559.853 uV 15:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.976 uVs 15:23:30 Integrated Voltage Measurement... 15:23:39 Voltage Offset Correction: v_off_ini = 558.654 uV, v_off_fin = 571.560 uV 15:23:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.836 uVs 15:23:39 Integrated Voltage Measurement... 15:23:48 Voltage Offset Correction: v_off_ini = 571.252 uV, v_off_fin = 559.841 uV 15:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.624 uVs 15:23:48 Integrated Voltage Measurement... 15:23:57 Voltage Offset Correction: v_off_ini = 565.811 uV, v_off_fin = 564.341 uV 15:23:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.716 uVs 15:23:57 Integrated Voltage Measurement... 15:24:06 Voltage Offset Correction: v_off_ini = 556.430 uV, v_off_fin = 560.232 uV 15:24:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.694 uVs 15:24:06 Integrated Voltage Measurement... 15:24:15 Voltage Offset Correction: v_off_ini = 567.232 uV, v_off_fin = 569.703 uV 15:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.532 uVs 15:24:19 I1X Average and RMS of Measurements VT = -61.730 +- 10.436 uVs I1X = 12.347 +- 2.087 uTm 15:24:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:24:26 Integrated Voltage Measurement... 15:24:35 Voltage Offset Correction: v_off_ini = 551.380 uV, v_off_fin = 542.332 uV 15:24:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -260.347 uVs 15:24:35 Integrated Voltage Measurement... 15:24:44 Voltage Offset Correction: v_off_ini = 557.729 uV, v_off_fin = 566.966 uV 15:24:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.999 uVs 15:24:44 Integrated Voltage Measurement... 15:24:53 Voltage Offset Correction: v_off_ini = 556.612 uV, v_off_fin = 539.292 uV 15:24:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.701 uVs 15:24:53 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 566.911 uV, v_off_fin = 575.696 uV 15:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.513 uVs 15:25:02 Integrated Voltage Measurement... 15:25:11 Voltage Offset Correction: v_off_ini = 571.001 uV, v_off_fin = 541.028 uV 15:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -265.535 uVs 15:25:11 Integrated Voltage Measurement... 15:25:20 Voltage Offset Correction: v_off_ini = 548.117 uV, v_off_fin = 558.311 uV 15:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 274.163 uVs 15:25:24 I1Y Average and RMS of Measurements VT = -264.376 +- 5.046 uVs I1Y = -52.874 +- 1.006 uTm 15:25:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:25:29 Integrated Voltage Measurement... 15:25:38 Voltage Offset Correction: v_off_ini = 544.514 uV, v_off_fin = 537.284 uV 15:25:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.345 uVs 15:25:38 Integrated Voltage Measurement... 15:25:47 Voltage Offset Correction: v_off_ini = 565.863 uV, v_off_fin = 568.710 uV 15:25:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.697 uVs 15:25:47 Integrated Voltage Measurement... 15:25:56 Voltage Offset Correction: v_off_ini = 562.620 uV, v_off_fin = 565.462 uV 15:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.410 uVs 15:25:56 Integrated Voltage Measurement... 15:26:05 Voltage Offset Correction: v_off_ini = 558.439 uV, v_off_fin = 568.331 uV 15:26:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.389 uVs 15:26:05 Integrated Voltage Measurement... 15:26:14 Voltage Offset Correction: v_off_ini = 554.135 uV, v_off_fin = 553.830 uV 15:26:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.108 uVs 15:26:14 Integrated Voltage Measurement... 15:26:23 Voltage Offset Correction: v_off_ini = 562.037 uV, v_off_fin = 544.121 uV 15:26:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.268 uVs 15:26:26 I2X Average and RMS of Measurements VT = -60.536 +- 9.993 uVs I2X = 5.570 +- 0.919 uTm^2 15:26:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:26:31 Integrated Voltage Measurement... 15:26:40 Voltage Offset Correction: v_off_ini = 548.015 uV, v_off_fin = 548.215 uV 15:26:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.273 uVs 15:26:40 Integrated Voltage Measurement... 15:26:49 Voltage Offset Correction: v_off_ini = 539.303 uV, v_off_fin = 549.714 uV 15:26:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 475.431 uVs 15:26:49 Integrated Voltage Measurement... 15:26:58 Voltage Offset Correction: v_off_ini = 557.269 uV, v_off_fin = 567.985 uV 15:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.526 uVs 15:26:58 Integrated Voltage Measurement... 15:27:07 Voltage Offset Correction: v_off_ini = 552.851 uV, v_off_fin = 542.920 uV 15:27:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 464.639 uVs 15:27:07 Integrated Voltage Measurement... 15:27:16 Voltage Offset Correction: v_off_ini = 553.829 uV, v_off_fin = 560.056 uV 15:27:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -454.548 uVs 15:27:16 Integrated Voltage Measurement... 15:27:25 Voltage Offset Correction: v_off_ini = 553.263 uV, v_off_fin = 552.266 uV 15:27:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 477.432 uVs 15:27:27 I2Y Average and RMS of Measurements VT = -465.475 +- 1.384 uVs I2Y = -42.824 +- 0.127 uTm^2 15:27:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:27:36 Integrated Voltage Measurement... 15:27:45 Voltage Offset Correction: v_off_ini = 558.252 uV, v_off_fin = 542.119 uV 15:27:45 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -74.723 uVs 15:27:45 Integrated Voltage Measurement... 15:27:54 Voltage Offset Correction: v_off_ini = 537.796 uV, v_off_fin = 525.307 uV 15:27:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 55.693 uVs 15:27:54 Integrated Voltage Measurement... 15:28:03 Voltage Offset Correction: v_off_ini = 533.045 uV, v_off_fin = 540.151 uV 15:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.832 uVs 15:28:03 Integrated Voltage Measurement... 15:28:12 Voltage Offset Correction: v_off_ini = 544.866 uV, v_off_fin = 550.763 uV 15:28:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.847 uVs 15:28:12 Integrated Voltage Measurement... 15:28:21 Voltage Offset Correction: v_off_ini = 546.260 uV, v_off_fin = 541.994 uV 15:28:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.563 uVs 15:28:21 Integrated Voltage Measurement... 15:28:30 Voltage Offset Correction: v_off_ini = 533.673 uV, v_off_fin = 545.006 uV 15:28:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.964 uVs 15:28:34 I1X Average and RMS of Measurements VT = -66.270 +- 4.120 uVs I1X = 13.255 +- 0.824 uTm 15:28:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:28:41 Integrated Voltage Measurement... 15:28:50 Voltage Offset Correction: v_off_ini = 532.581 uV, v_off_fin = 516.583 uV 15:28:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -269.291 uVs 15:28:50 Integrated Voltage Measurement... 15:28:59 Voltage Offset Correction: v_off_ini = 536.503 uV, v_off_fin = 557.360 uV 15:28:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.983 uVs 15:28:59 Integrated Voltage Measurement... 15:29:08 Voltage Offset Correction: v_off_ini = 560.224 uV, v_off_fin = 533.518 uV 15:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.568 uVs 15:29:08 Integrated Voltage Measurement... 15:29:17 Voltage Offset Correction: v_off_ini = 538.638 uV, v_off_fin = 547.911 uV 15:29:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.511 uVs 15:29:17 Integrated Voltage Measurement... 15:29:26 Voltage Offset Correction: v_off_ini = 545.997 uV, v_off_fin = 540.406 uV 15:29:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.740 uVs 15:29:26 Integrated Voltage Measurement... 15:29:35 Voltage Offset Correction: v_off_ini = 559.797 uV, v_off_fin = 553.585 uV 15:29:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.055 uVs 15:29:39 I1Y Average and RMS of Measurements VT = -266.025 +- 5.647 uVs I1Y = -53.204 +- 1.129 uTm 15:29:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:29:44 Integrated Voltage Measurement... 15:29:53 Voltage Offset Correction: v_off_ini = 538.406 uV, v_off_fin = 530.695 uV 15:29:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.086 uVs 15:29:53 Integrated Voltage Measurement... 15:30:02 Voltage Offset Correction: v_off_ini = 538.970 uV, v_off_fin = 552.525 uV 15:30:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.889 uVs 15:30:02 Integrated Voltage Measurement... 15:30:11 Voltage Offset Correction: v_off_ini = 544.757 uV, v_off_fin = 556.154 uV 15:30:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -50.896 uVs 15:30:11 Integrated Voltage Measurement... 15:30:20 Voltage Offset Correction: v_off_ini = 565.952 uV, v_off_fin = 559.535 uV 15:30:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.077 uVs 15:30:20 Integrated Voltage Measurement... 15:30:29 Voltage Offset Correction: v_off_ini = 540.848 uV, v_off_fin = 538.305 uV 15:30:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -50.688 uVs 15:30:29 Integrated Voltage Measurement... 15:30:38 Voltage Offset Correction: v_off_ini = 547.618 uV, v_off_fin = 563.672 uV 15:30:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.560 uVs 15:30:41 I2X Average and RMS of Measurements VT = -52.533 +- 4.537 uVs I2X = 4.833 +- 0.417 uTm^2 15:30:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:30:46 Integrated Voltage Measurement... 15:30:55 Voltage Offset Correction: v_off_ini = 559.103 uV, v_off_fin = 556.369 uV 15:30:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -471.371 uVs 15:30:55 Integrated Voltage Measurement... 15:31:04 Voltage Offset Correction: v_off_ini = 553.239 uV, v_off_fin = 548.965 uV 15:31:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 468.555 uVs 15:31:04 Integrated Voltage Measurement... 15:31:13 Voltage Offset Correction: v_off_ini = 549.918 uV, v_off_fin = 553.411 uV 15:31:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -463.512 uVs 15:31:13 Integrated Voltage Measurement... 15:31:22 Voltage Offset Correction: v_off_ini = 565.338 uV, v_off_fin = 558.120 uV 15:31:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 464.732 uVs 15:31:22 Integrated Voltage Measurement... 15:31:31 Voltage Offset Correction: v_off_ini = 556.931 uV, v_off_fin = 554.586 uV 15:31:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -472.337 uVs 15:31:31 Integrated Voltage Measurement... 15:31:40 Voltage Offset Correction: v_off_ini = 553.672 uV, v_off_fin = 548.400 uV 15:31:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.465 uVs 15:31:42 I2Y Average and RMS of Measurements VT = -471.829 +- 7.177 uVs I2Y = -43.408 +- 0.660 uTm^2 15:31:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:32:04 Integrated Voltage Measurement... 15:32:13 Voltage Offset Correction: v_off_ini = 558.964 uV, v_off_fin = 549.667 uV 15:32:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.562 uVs 15:32:13 Integrated Voltage Measurement... 15:32:22 Voltage Offset Correction: v_off_ini = 565.586 uV, v_off_fin = 564.678 uV 15:32:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.286 uVs 15:32:22 Integrated Voltage Measurement... 15:32:31 Voltage Offset Correction: v_off_ini = 552.427 uV, v_off_fin = 554.315 uV 15:32:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.740 uVs 15:32:31 Integrated Voltage Measurement... 15:32:40 Voltage Offset Correction: v_off_ini = 558.784 uV, v_off_fin = 557.132 uV 15:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.305 uVs 15:32:40 Integrated Voltage Measurement... 15:32:49 Voltage Offset Correction: v_off_ini = 568.688 uV, v_off_fin = 551.989 uV 15:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.995 uVs 15:32:49 Integrated Voltage Measurement... 15:32:58 Voltage Offset Correction: v_off_ini = 549.153 uV, v_off_fin = 562.043 uV 15:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.586 uVs 15:33:02 I1X Average and RMS of Measurements VT = -57.412 +- 5.649 uVs I1X = 11.483 +- 1.130 uTm 15:33:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:33:09 Integrated Voltage Measurement... 15:33:18 Voltage Offset Correction: v_off_ini = 550.832 uV, v_off_fin = 531.949 uV 15:33:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.320 uVs 15:33:18 Integrated Voltage Measurement... 15:33:27 Voltage Offset Correction: v_off_ini = 547.229 uV, v_off_fin = 559.735 uV 15:33:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.912 uVs 15:33:27 Integrated Voltage Measurement... 15:33:36 Voltage Offset Correction: v_off_ini = 537.706 uV, v_off_fin = 525.839 uV 15:33:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.141 uVs 15:33:36 Integrated Voltage Measurement... 15:33:45 Voltage Offset Correction: v_off_ini = 552.969 uV, v_off_fin = 551.668 uV 15:33:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.605 uVs 15:33:45 Integrated Voltage Measurement... 15:33:54 Voltage Offset Correction: v_off_ini = 549.383 uV, v_off_fin = 535.891 uV 15:33:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.177 uVs 15:33:54 Integrated Voltage Measurement... 15:34:03 Voltage Offset Correction: v_off_ini = 544.815 uV, v_off_fin = 556.151 uV 15:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.945 uVs 15:34:07 I1Y Average and RMS of Measurements VT = -253.517 +- 1.877 uVs I1Y = -50.703 +- 0.375 uTm 15:34:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:34:15 Integrated Voltage Measurement... 15:34:24 Voltage Offset Correction: v_off_ini = 548.050 uV, v_off_fin = 547.306 uV 15:34:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.777 uVs 15:34:24 Integrated Voltage Measurement... 15:34:33 Voltage Offset Correction: v_off_ini = 553.553 uV, v_off_fin = 563.737 uV 15:34:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.273 uVs 15:34:33 Integrated Voltage Measurement... 15:34:42 Voltage Offset Correction: v_off_ini = 553.355 uV, v_off_fin = 537.615 uV 15:34:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.927 uVs 15:34:42 Integrated Voltage Measurement... 15:34:51 Voltage Offset Correction: v_off_ini = 547.323 uV, v_off_fin = 543.747 uV 15:34:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.789 uVs 15:34:51 Integrated Voltage Measurement... 15:35:00 Voltage Offset Correction: v_off_ini = 548.745 uV, v_off_fin = 540.550 uV 15:35:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.591 uVs 15:35:00 Integrated Voltage Measurement... 15:35:09 Voltage Offset Correction: v_off_ini = 544.432 uV, v_off_fin = 558.738 uV 15:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.461 uVs 15:35:11 I2X Average and RMS of Measurements VT = -51.803 +- 4.743 uVs I2X = 4.766 +- 0.436 uTm^2 15:35:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:35:19 Integrated Voltage Measurement... 15:35:28 Voltage Offset Correction: v_off_ini = 542.228 uV, v_off_fin = 540.202 uV 15:35:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.281 uVs 15:35:28 Integrated Voltage Measurement... 15:35:37 Voltage Offset Correction: v_off_ini = 541.649 uV, v_off_fin = 550.155 uV 15:35:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 448.298 uVs 15:35:37 Integrated Voltage Measurement... 15:35:46 Voltage Offset Correction: v_off_ini = 553.764 uV, v_off_fin = 555.127 uV 15:35:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -457.876 uVs 15:35:46 Integrated Voltage Measurement... 15:35:55 Voltage Offset Correction: v_off_ini = 561.922 uV, v_off_fin = 545.169 uV 15:35:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.367 uVs 15:35:55 Integrated Voltage Measurement... 15:36:04 Voltage Offset Correction: v_off_ini = 529.339 uV, v_off_fin = 529.979 uV 15:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.324 uVs 15:36:04 Integrated Voltage Measurement... 15:36:13 Voltage Offset Correction: v_off_ini = 527.788 uV, v_off_fin = 541.593 uV 15:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 417.251 uVs 15:36:16 I2Y Average and RMS of Measurements VT = -440.066 +- 10.599 uVs I2Y = -40.486 +- 0.975 uTm^2 15:36:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:36:24 Integrated Voltage Measurement... 15:36:33 Voltage Offset Correction: v_off_ini = 548.841 uV, v_off_fin = 550.244 uV 15:36:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.048 uVs 15:36:34 Integrated Voltage Measurement... 15:36:42 Voltage Offset Correction: v_off_ini = 523.344 uV, v_off_fin = 535.068 uV 15:36:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.926 uVs 15:36:43 Integrated Voltage Measurement... 15:36:51 Voltage Offset Correction: v_off_ini = 532.853 uV, v_off_fin = 534.767 uV 15:36:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.024 uVs 15:36:52 Integrated Voltage Measurement... 15:37:00 Voltage Offset Correction: v_off_ini = 532.779 uV, v_off_fin = 533.449 uV 15:37:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.187 uVs 15:37:01 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 531.843 uV, v_off_fin = 532.084 uV 15:37:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.926 uVs 15:37:10 Integrated Voltage Measurement... 15:37:19 Voltage Offset Correction: v_off_ini = 543.437 uV, v_off_fin = 538.743 uV 15:37:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.216 uVs 15:37:23 I1X Average and RMS of Measurements VT = -69.388 +- 13.274 uVs I1X = 13.878 +- 2.655 uTm 15:37:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:37:30 Integrated Voltage Measurement... 15:37:38 Voltage Offset Correction: v_off_ini = 538.073 uV, v_off_fin = 529.756 uV 15:37:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.649 uVs 15:37:39 Integrated Voltage Measurement... 15:37:47 Voltage Offset Correction: v_off_ini = 532.156 uV, v_off_fin = 539.130 uV 15:37:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.885 uVs 15:37:48 Integrated Voltage Measurement... 15:37:56 Voltage Offset Correction: v_off_ini = 529.906 uV, v_off_fin = 529.685 uV 15:37:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.442 uVs 15:37:57 Integrated Voltage Measurement... 15:38:05 Voltage Offset Correction: v_off_ini = 542.556 uV, v_off_fin = 548.042 uV 15:38:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.614 uVs 15:38:06 Integrated Voltage Measurement... 15:38:14 Voltage Offset Correction: v_off_ini = 542.902 uV, v_off_fin = 515.062 uV 15:38:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.026 uVs 15:38:15 Integrated Voltage Measurement... 15:38:23 Voltage Offset Correction: v_off_ini = 531.018 uV, v_off_fin = 555.644 uV 15:38:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.928 uVs 15:38:28 I1Y Average and RMS of Measurements VT = -242.591 +- 6.489 uVs I1Y = -48.518 +- 1.298 uTm 15:38:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:38:35 Integrated Voltage Measurement... 15:38:44 Voltage Offset Correction: v_off_ini = 525.478 uV, v_off_fin = 533.308 uV 15:38:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.957 uVs 15:38:44 Integrated Voltage Measurement... 15:38:53 Voltage Offset Correction: v_off_ini = 539.130 uV, v_off_fin = 542.251 uV 15:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.017 uVs 15:38:54 Integrated Voltage Measurement... 15:39:02 Voltage Offset Correction: v_off_ini = 529.377 uV, v_off_fin = 512.903 uV 15:39:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.468 uVs 15:39:03 Integrated Voltage Measurement... 15:39:12 Voltage Offset Correction: v_off_ini = 514.855 uV, v_off_fin = 519.195 uV 15:39:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.421 uVs 15:39:12 Integrated Voltage Measurement... 15:39:21 Voltage Offset Correction: v_off_ini = 538.011 uV, v_off_fin = 519.646 uV 15:39:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -61.245 uVs 15:39:21 Integrated Voltage Measurement... 15:39:30 Voltage Offset Correction: v_off_ini = 529.518 uV, v_off_fin = 542.487 uV 15:39:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.583 uVs 15:39:32 I2X Average and RMS of Measurements VT = -62.615 +- 7.411 uVs I2X = 5.761 +- 0.682 uTm^2 15:39:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:39:40 Integrated Voltage Measurement... 15:39:49 Voltage Offset Correction: v_off_ini = 516.321 uV, v_off_fin = 526.777 uV 15:39:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -413.554 uVs 15:39:49 Integrated Voltage Measurement... 15:39:58 Voltage Offset Correction: v_off_ini = 532.384 uV, v_off_fin = 533.029 uV 15:39:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.940 uVs 15:39:58 Integrated Voltage Measurement... 15:40:07 Voltage Offset Correction: v_off_ini = 534.215 uV, v_off_fin = 524.222 uV 15:40:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -442.355 uVs 15:40:07 Integrated Voltage Measurement... 15:40:16 Voltage Offset Correction: v_off_ini = 531.507 uV, v_off_fin = 524.287 uV 15:40:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.864 uVs 15:40:16 Integrated Voltage Measurement... 15:40:25 Voltage Offset Correction: v_off_ini = 517.209 uV, v_off_fin = 520.825 uV 15:40:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -435.266 uVs 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = 506.888 uV, v_off_fin = 515.113 uV 15:40:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 424.061 uVs 15:40:36 I2Y Average and RMS of Measurements VT = -429.174 +- 11.584 uVs I2Y = -39.484 +- 1.066 uTm^2 15:40:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:45 Integrated Voltage Measurement... 15:40:54 Voltage Offset Correction: v_off_ini = 521.124 uV, v_off_fin = 532.843 uV 15:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.041 uVs 15:40:54 Integrated Voltage Measurement... 15:41:03 Voltage Offset Correction: v_off_ini = 522.935 uV, v_off_fin = 526.571 uV 15:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.223 uVs 15:41:03 Integrated Voltage Measurement... 15:41:12 Voltage Offset Correction: v_off_ini = 523.312 uV, v_off_fin = 518.596 uV 15:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.916 uVs 15:41:12 Integrated Voltage Measurement... 15:41:21 Voltage Offset Correction: v_off_ini = 530.010 uV, v_off_fin = 523.876 uV 15:41:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.435 uVs 15:41:21 Integrated Voltage Measurement... 15:41:30 Voltage Offset Correction: v_off_ini = 522.607 uV, v_off_fin = 521.793 uV 15:41:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.427 uVs 15:41:30 Integrated Voltage Measurement... 15:41:39 Voltage Offset Correction: v_off_ini = 520.745 uV, v_off_fin = 529.810 uV 15:41:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.660 uVs 15:41:44 I1X Average and RMS of Measurements VT = -70.450 +- 9.405 uVs I1X = 14.091 +- 1.881 uTm 15:41:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:50 Integrated Voltage Measurement... 15:41:59 Voltage Offset Correction: v_off_ini = 516.856 uV, v_off_fin = 515.803 uV 15:41:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.678 uVs 15:41:59 Integrated Voltage Measurement... 15:42:08 Voltage Offset Correction: v_off_ini = 530.128 uV, v_off_fin = 532.194 uV 15:42:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.190 uVs 15:42:08 Integrated Voltage Measurement... 15:42:17 Voltage Offset Correction: v_off_ini = 523.374 uV, v_off_fin = 524.598 uV 15:42:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.321 uVs 15:42:17 Integrated Voltage Measurement... 15:42:26 Voltage Offset Correction: v_off_ini = 527.967 uV, v_off_fin = 542.311 uV 15:42:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.588 uVs 15:42:26 Integrated Voltage Measurement... 15:42:35 Voltage Offset Correction: v_off_ini = 532.845 uV, v_off_fin = 523.290 uV 15:42:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.318 uVs 15:42:35 Integrated Voltage Measurement... 15:42:44 Voltage Offset Correction: v_off_ini = 532.683 uV, v_off_fin = 540.874 uV 15:42:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.106 uVs 15:42:48 I1Y Average and RMS of Measurements VT = -223.534 +- 2.532 uVs I1Y = -44.707 +- 0.506 uTm 15:42:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:56 Integrated Voltage Measurement... 15:43:05 Voltage Offset Correction: v_off_ini = 529.241 uV, v_off_fin = 511.662 uV 15:43:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.436 uVs 15:43:05 Integrated Voltage Measurement... 15:43:14 Voltage Offset Correction: v_off_ini = 523.142 uV, v_off_fin = 531.925 uV 15:43:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.531 uVs 15:43:14 Integrated Voltage Measurement... 15:43:23 Voltage Offset Correction: v_off_ini = 511.913 uV, v_off_fin = 511.046 uV 15:43:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.403 uVs 15:43:23 Integrated Voltage Measurement... 15:43:32 Voltage Offset Correction: v_off_ini = 513.809 uV, v_off_fin = 521.860 uV 15:43:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.308 uVs 15:43:32 Integrated Voltage Measurement... 15:43:41 Voltage Offset Correction: v_off_ini = 508.914 uV, v_off_fin = 516.307 uV 15:43:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -68.426 uVs 15:43:41 Integrated Voltage Measurement... 15:43:50 Voltage Offset Correction: v_off_ini = 517.920 uV, v_off_fin = 521.444 uV 15:43:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.931 uVs 15:43:53 I2X Average and RMS of Measurements VT = -69.839 +- 2.594 uVs I2X = 6.426 +- 0.239 uTm^2 15:43:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:00 Integrated Voltage Measurement... 15:44:09 Voltage Offset Correction: v_off_ini = 518.105 uV, v_off_fin = 525.451 uV 15:44:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.925 uVs 15:44:10 Integrated Voltage Measurement... 15:44:19 Voltage Offset Correction: v_off_ini = 510.890 uV, v_off_fin = 526.255 uV 15:44:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.909 uVs 15:44:19 Integrated Voltage Measurement... 15:44:28 Voltage Offset Correction: v_off_ini = 520.844 uV, v_off_fin = 522.989 uV 15:44:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.981 uVs 15:44:28 Integrated Voltage Measurement... 15:44:37 Voltage Offset Correction: v_off_ini = 514.932 uV, v_off_fin = 522.008 uV 15:44:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.579 uVs 15:44:37 Integrated Voltage Measurement... 15:44:46 Voltage Offset Correction: v_off_ini = 519.313 uV, v_off_fin = 520.895 uV 15:44:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -409.535 uVs 15:44:46 Integrated Voltage Measurement... 15:44:55 Voltage Offset Correction: v_off_ini = 517.299 uV, v_off_fin = 516.632 uV 15:44:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.996 uVs 15:44:57 I2Y Average and RMS of Measurements VT = -413.488 +- 3.961 uVs I2Y = -38.041 +- 0.364 uTm^2 15:45:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:45:06 Integrated Voltage Measurement... 15:45:15 Voltage Offset Correction: v_off_ini = 513.141 uV, v_off_fin = 504.379 uV 15:45:15 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -76.792 uVs 15:45:15 Integrated Voltage Measurement... 15:45:24 Voltage Offset Correction: v_off_ini = 507.802 uV, v_off_fin = 508.483 uV 15:45:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.155 uVs 15:45:24 Integrated Voltage Measurement... 15:45:33 Voltage Offset Correction: v_off_ini = 510.274 uV, v_off_fin = 508.819 uV 15:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.169 uVs 15:45:33 Integrated Voltage Measurement... 15:45:42 Voltage Offset Correction: v_off_ini = 533.907 uV, v_off_fin = 525.590 uV 15:45:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.848 uVs 15:45:42 Integrated Voltage Measurement... 15:45:51 Voltage Offset Correction: v_off_ini = 507.289 uV, v_off_fin = 510.103 uV 15:45:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.473 uVs 15:45:51 Integrated Voltage Measurement... 15:46:00 Voltage Offset Correction: v_off_ini = 491.290 uV, v_off_fin = 508.148 uV 15:46:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.690 uVs 15:46:04 I1X Average and RMS of Measurements VT = -79.354 +- 6.975 uVs I1X = 15.872 +- 1.395 uTm 15:46:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:46:11 Integrated Voltage Measurement... 15:46:20 Voltage Offset Correction: v_off_ini = 483.985 uV, v_off_fin = 484.284 uV 15:46:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -198.703 uVs 15:46:20 Integrated Voltage Measurement... 15:46:29 Voltage Offset Correction: v_off_ini = 499.478 uV, v_off_fin = 511.578 uV 15:46:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.705 uVs 15:46:29 Integrated Voltage Measurement... 15:46:38 Voltage Offset Correction: v_off_ini = 510.064 uV, v_off_fin = 506.209 uV 15:46:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.455 uVs 15:46:38 Integrated Voltage Measurement... 15:46:47 Voltage Offset Correction: v_off_ini = 501.369 uV, v_off_fin = 508.826 uV 15:46:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.326 uVs 15:46:47 Integrated Voltage Measurement... 15:46:56 Voltage Offset Correction: v_off_ini = 494.550 uV, v_off_fin = 494.616 uV 15:46:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.849 uVs 15:46:56 Integrated Voltage Measurement... 15:47:05 Voltage Offset Correction: v_off_ini = 502.908 uV, v_off_fin = 511.532 uV 15:47:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.244 uVs 15:47:09 I1Y Average and RMS of Measurements VT = -212.880 +- 4.519 uVs I1Y = -42.577 +- 0.903 uTm 15:47:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:47:17 Integrated Voltage Measurement... 15:47:26 Voltage Offset Correction: v_off_ini = 499.462 uV, v_off_fin = 498.321 uV 15:47:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.433 uVs 15:47:26 Integrated Voltage Measurement... 15:47:35 Voltage Offset Correction: v_off_ini = 506.404 uV, v_off_fin = 509.470 uV 15:47:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 51.930 uVs 15:47:35 Integrated Voltage Measurement... 15:47:44 Voltage Offset Correction: v_off_ini = 486.600 uV, v_off_fin = 479.687 uV 15:47:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.004 uVs 15:47:44 Integrated Voltage Measurement... 15:47:53 Voltage Offset Correction: v_off_ini = 489.075 uV, v_off_fin = 492.027 uV 15:47:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.237 uVs 15:47:53 Integrated Voltage Measurement... 15:48:02 Voltage Offset Correction: v_off_ini = 479.694 uV, v_off_fin = 475.111 uV 15:48:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.565 uVs 15:48:02 Integrated Voltage Measurement... 15:48:11 Voltage Offset Correction: v_off_ini = 482.941 uV, v_off_fin = 483.760 uV 15:48:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.371 uVs 15:48:14 I2X Average and RMS of Measurements VT = -63.757 +- 4.039 uVs I2X = 5.866 +- 0.371 uTm^2 15:48:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:48:21 Integrated Voltage Measurement... 15:48:30 Voltage Offset Correction: v_off_ini = 486.238 uV, v_off_fin = 501.351 uV 15:48:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.865 uVs 15:48:30 Integrated Voltage Measurement... 15:48:39 Voltage Offset Correction: v_off_ini = 492.496 uV, v_off_fin = 489.032 uV 15:48:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 388.704 uVs 15:48:39 Integrated Voltage Measurement... 15:48:48 Voltage Offset Correction: v_off_ini = 474.934 uV, v_off_fin = 477.422 uV 15:48:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.302 uVs 15:48:48 Integrated Voltage Measurement... 15:48:57 Voltage Offset Correction: v_off_ini = 470.250 uV, v_off_fin = 476.153 uV 15:48:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 398.083 uVs 15:48:57 Integrated Voltage Measurement... 15:49:06 Voltage Offset Correction: v_off_ini = 476.024 uV, v_off_fin = 493.011 uV 15:49:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.912 uVs 15:49:06 Integrated Voltage Measurement... 15:49:15 Voltage Offset Correction: v_off_ini = 489.561 uV, v_off_fin = 488.768 uV 15:49:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.012 uVs 15:49:18 I2Y Average and RMS of Measurements VT = -390.813 +- 5.721 uVs I2Y = -35.955 +- 0.526 uTm^2 15:49:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:49:27 Integrated Voltage Measurement... 15:49:36 Voltage Offset Correction: v_off_ini = 474.616 uV, v_off_fin = 471.261 uV 15:49:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.903 uVs 15:49:36 Integrated Voltage Measurement... 15:49:45 Voltage Offset Correction: v_off_ini = 483.993 uV, v_off_fin = 474.769 uV 15:49:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.057 uVs 15:49:45 Integrated Voltage Measurement... 15:49:54 Voltage Offset Correction: v_off_ini = 475.219 uV, v_off_fin = 483.054 uV 15:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.472 uVs 15:49:54 Integrated Voltage Measurement... 15:50:03 Voltage Offset Correction: v_off_ini = 490.590 uV, v_off_fin = 485.044 uV 15:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.019 uVs 15:50:03 Integrated Voltage Measurement... 15:50:12 Voltage Offset Correction: v_off_ini = 479.685 uV, v_off_fin = 478.081 uV 15:50:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.714 uVs 15:50:12 Integrated Voltage Measurement... 15:50:21 Voltage Offset Correction: v_off_ini = 485.895 uV, v_off_fin = 482.517 uV 15:50:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.319 uVs 15:50:25 I1X Average and RMS of Measurements VT = -91.914 +- 2.561 uVs I1X = 18.383 +- 0.512 uTm 15:50:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:50:32 Integrated Voltage Measurement... 15:50:41 Voltage Offset Correction: v_off_ini = 486.107 uV, v_off_fin = 481.421 uV 15:50:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.438 uVs 15:50:41 Integrated Voltage Measurement... 15:50:50 Voltage Offset Correction: v_off_ini = 486.029 uV, v_off_fin = 491.495 uV 15:50:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.676 uVs 15:50:50 Integrated Voltage Measurement... 15:50:59 Voltage Offset Correction: v_off_ini = 486.270 uV, v_off_fin = 470.681 uV 15:50:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.119 uVs 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = 487.900 uV, v_off_fin = 491.189 uV 15:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.148 uVs 15:51:08 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = 492.346 uV, v_off_fin = 476.697 uV 15:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.181 uVs 15:51:17 Integrated Voltage Measurement... 15:51:26 Voltage Offset Correction: v_off_ini = 467.015 uV, v_off_fin = 495.941 uV 15:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.853 uVs 15:51:30 I1Y Average and RMS of Measurements VT = -193.569 +- 4.180 uVs I1Y = -38.714 +- 0.836 uTm 15:51:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:51:38 Integrated Voltage Measurement... 15:51:47 Voltage Offset Correction: v_off_ini = 478.946 uV, v_off_fin = 460.528 uV 15:51:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.306 uVs 15:51:47 Integrated Voltage Measurement... 15:51:56 Voltage Offset Correction: v_off_ini = 469.232 uV, v_off_fin = 486.205 uV 15:51:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.578 uVs 15:51:56 Integrated Voltage Measurement... 15:52:05 Voltage Offset Correction: v_off_ini = 476.631 uV, v_off_fin = 472.497 uV 15:52:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.293 uVs 15:52:05 Integrated Voltage Measurement... 15:52:14 Voltage Offset Correction: v_off_ini = 476.816 uV, v_off_fin = 489.041 uV 15:52:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.068 uVs 15:52:14 Integrated Voltage Measurement... 15:52:23 Voltage Offset Correction: v_off_ini = 479.292 uV, v_off_fin = 472.254 uV 15:52:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.118 uVs 15:52:23 Integrated Voltage Measurement... 15:52:32 Voltage Offset Correction: v_off_ini = 484.033 uV, v_off_fin = 498.719 uV 15:52:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.274 uVs 15:52:34 I2X Average and RMS of Measurements VT = -89.773 +- 0.831 uVs I2X = 8.259 +- 0.076 uTm^2 15:52:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:52:42 Integrated Voltage Measurement... 15:52:51 Voltage Offset Correction: v_off_ini = 478.241 uV, v_off_fin = 464.388 uV 15:52:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.085 uVs 15:52:51 Integrated Voltage Measurement... 15:53:00 Voltage Offset Correction: v_off_ini = 480.564 uV, v_off_fin = 486.947 uV 15:53:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.841 uVs 15:53:00 Integrated Voltage Measurement... 15:53:09 Voltage Offset Correction: v_off_ini = 477.078 uV, v_off_fin = 487.255 uV 15:53:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.899 uVs 15:53:09 Integrated Voltage Measurement... 15:53:18 Voltage Offset Correction: v_off_ini = 480.632 uV, v_off_fin = 472.842 uV 15:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.486 uVs 15:53:18 Integrated Voltage Measurement... 15:53:27 Voltage Offset Correction: v_off_ini = 478.073 uV, v_off_fin = 487.773 uV 15:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.147 uVs 15:53:27 Integrated Voltage Measurement... 15:53:36 Voltage Offset Correction: v_off_ini = 498.187 uV, v_off_fin = 486.537 uV 15:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.899 uVs 15:53:39 I2Y Average and RMS of Measurements VT = -370.559 +- 3.985 uVs I2Y = -34.091 +- 0.367 uTm^2 15:53:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:53:51 Integrated Voltage Measurement... 15:54:00 Voltage Offset Correction: v_off_ini = 492.208 uV, v_off_fin = 471.011 uV 15:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.070 uVs 15:54:00 Integrated Voltage Measurement... 15:54:09 Voltage Offset Correction: v_off_ini = 478.546 uV, v_off_fin = 480.363 uV 15:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.254 uVs 15:54:09 Integrated Voltage Measurement... 15:54:18 Voltage Offset Correction: v_off_ini = 479.187 uV, v_off_fin = 478.267 uV 15:54:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -60.972 uVs 15:54:18 Integrated Voltage Measurement... 15:54:27 Voltage Offset Correction: v_off_ini = 479.162 uV, v_off_fin = 486.839 uV 15:54:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 51.018 uVs 15:54:27 Integrated Voltage Measurement... 15:54:36 Voltage Offset Correction: v_off_ini = 492.566 uV, v_off_fin = 477.878 uV 15:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.759 uVs 15:54:36 Integrated Voltage Measurement... 15:54:45 Voltage Offset Correction: v_off_ini = 477.432 uV, v_off_fin = 471.061 uV 15:54:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.556 uVs 15:54:49 I1X Average and RMS of Measurements VT = -57.105 +- 5.771 uVs I1X = 11.422 +- 1.154 uTm 15:54:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:54:56 Integrated Voltage Measurement... 15:55:05 Voltage Offset Correction: v_off_ini = 479.240 uV, v_off_fin = 466.006 uV 15:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.306 uVs 15:55:05 Integrated Voltage Measurement... 15:55:14 Voltage Offset Correction: v_off_ini = 484.124 uV, v_off_fin = 493.030 uV 15:55:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.203 uVs 15:55:14 Integrated Voltage Measurement... 15:55:23 Voltage Offset Correction: v_off_ini = 468.838 uV, v_off_fin = 472.939 uV 15:55:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.276 uVs 15:55:23 Integrated Voltage Measurement... 15:55:32 Voltage Offset Correction: v_off_ini = 461.315 uV, v_off_fin = 478.570 uV 15:55:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.564 uVs 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = 467.673 uV, v_off_fin = 464.859 uV 15:55:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.590 uVs 15:55:41 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = 482.214 uV, v_off_fin = 490.821 uV 15:55:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.292 uVs 15:55:54 I1Y Average and RMS of Measurements VT = -222.539 +- 4.283 uVs I1Y = -44.508 +- 0.857 uTm 15:55:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:55:59 Integrated Voltage Measurement... 15:56:08 Voltage Offset Correction: v_off_ini = 469.044 uV, v_off_fin = 466.104 uV 15:56:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.259 uVs 15:56:08 Integrated Voltage Measurement... 15:56:17 Voltage Offset Correction: v_off_ini = 460.175 uV, v_off_fin = 478.369 uV 15:56:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.402 uVs 15:56:17 Integrated Voltage Measurement... 15:56:26 Voltage Offset Correction: v_off_ini = 473.546 uV, v_off_fin = 453.048 uV 15:56:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.300 uVs 15:56:26 Integrated Voltage Measurement... 15:56:35 Voltage Offset Correction: v_off_ini = 462.104 uV, v_off_fin = 463.919 uV 15:56:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.116 uVs 15:56:35 Integrated Voltage Measurement... 15:56:44 Voltage Offset Correction: v_off_ini = 461.259 uV, v_off_fin = 446.974 uV 15:56:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.563 uVs 15:56:44 Integrated Voltage Measurement... 15:56:53 Voltage Offset Correction: v_off_ini = 454.328 uV, v_off_fin = 467.320 uV 15:56:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.277 uVs 15:56:56 I2X Average and RMS of Measurements VT = -37.653 +- 2.546 uVs I2X = 3.464 +- 0.234 uTm^2 15:56:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:57:01 Integrated Voltage Measurement... 15:57:10 Voltage Offset Correction: v_off_ini = 455.036 uV, v_off_fin = 459.610 uV 15:57:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.696 uVs 15:57:10 Integrated Voltage Measurement... 15:57:19 Voltage Offset Correction: v_off_ini = 449.845 uV, v_off_fin = 449.633 uV 15:57:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.093 uVs 15:57:19 Integrated Voltage Measurement... 15:57:28 Voltage Offset Correction: v_off_ini = 438.250 uV, v_off_fin = 444.207 uV 15:57:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.642 uVs 15:57:28 Integrated Voltage Measurement... 15:57:37 Voltage Offset Correction: v_off_ini = 466.394 uV, v_off_fin = 448.660 uV 15:57:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.702 uVs 15:57:37 Integrated Voltage Measurement... 15:57:46 Voltage Offset Correction: v_off_ini = 443.216 uV, v_off_fin = 441.776 uV 15:57:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.252 uVs 15:57:46 Integrated Voltage Measurement... 15:57:55 Voltage Offset Correction: v_off_ini = 450.876 uV, v_off_fin = 441.235 uV 15:57:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.808 uVs 15:57:57 I2Y Average and RMS of Measurements VT = -411.366 +- 1.907 uVs I2Y = -37.846 +- 0.175 uTm^2 15:58:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:58:06 Integrated Voltage Measurement... 15:58:15 Voltage Offset Correction: v_off_ini = 448.859 uV, v_off_fin = 446.296 uV 15:58:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.352 uVs 15:58:15 Integrated Voltage Measurement... 15:58:24 Voltage Offset Correction: v_off_ini = 457.971 uV, v_off_fin = 453.718 uV 15:58:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.472 uVs 15:58:24 Integrated Voltage Measurement... 15:58:33 Voltage Offset Correction: v_off_ini = 447.199 uV, v_off_fin = 446.709 uV 15:58:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.461 uVs 15:58:33 Integrated Voltage Measurement... 15:58:42 Voltage Offset Correction: v_off_ini = 453.097 uV, v_off_fin = 458.632 uV 15:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.074 uVs 15:58:42 Integrated Voltage Measurement... 15:58:51 Voltage Offset Correction: v_off_ini = 453.605 uV, v_off_fin = 446.614 uV 15:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.429 uVs 15:58:51 Integrated Voltage Measurement... 15:59:00 Voltage Offset Correction: v_off_ini = 457.174 uV, v_off_fin = 456.277 uV 15:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.052 uVs 15:59:04 I1X Average and RMS of Measurements VT = -61.307 +- 5.100 uVs I1X = 12.261 +- 1.020 uTm 15:59:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:59:11 Integrated Voltage Measurement... 15:59:20 Voltage Offset Correction: v_off_ini = 454.962 uV, v_off_fin = 447.472 uV 15:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.121 uVs 15:59:20 Integrated Voltage Measurement... 15:59:29 Voltage Offset Correction: v_off_ini = 455.416 uV, v_off_fin = 457.930 uV 15:59:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.385 uVs 15:59:29 Integrated Voltage Measurement... 15:59:38 Voltage Offset Correction: v_off_ini = 445.782 uV, v_off_fin = 447.496 uV 15:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.837 uVs 15:59:38 Integrated Voltage Measurement... 15:59:47 Voltage Offset Correction: v_off_ini = 432.983 uV, v_off_fin = 450.879 uV 15:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.810 uVs 15:59:47 Integrated Voltage Measurement... 15:59:56 Voltage Offset Correction: v_off_ini = 448.910 uV, v_off_fin = 444.834 uV 15:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.676 uVs 15:59:56 Integrated Voltage Measurement... 16:00:05 Voltage Offset Correction: v_off_ini = 455.388 uV, v_off_fin = 470.049 uV 16:00:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.316 uVs 16:00:09 I1Y Average and RMS of Measurements VT = -223.524 +- 3.707 uVs I1Y = -44.705 +- 0.741 uTm 16:00:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:00:14 Integrated Voltage Measurement... 16:00:23 Voltage Offset Correction: v_off_ini = 444.983 uV, v_off_fin = 440.940 uV 16:00:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.290 uVs 16:00:23 Integrated Voltage Measurement... 16:00:32 Voltage Offset Correction: v_off_ini = 429.966 uV, v_off_fin = 450.688 uV 16:00:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.569 uVs 16:00:32 Integrated Voltage Measurement... 16:00:41 Voltage Offset Correction: v_off_ini = 449.583 uV, v_off_fin = 446.921 uV 16:00:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.857 uVs 16:00:41 Integrated Voltage Measurement... 16:00:50 Voltage Offset Correction: v_off_ini = 457.601 uV, v_off_fin = 460.970 uV 16:00:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.344 uVs 16:00:50 Integrated Voltage Measurement... 16:00:59 Voltage Offset Correction: v_off_ini = 463.004 uV, v_off_fin = 448.835 uV 16:00:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.344 uVs 16:00:59 Integrated Voltage Measurement... 16:01:08 Voltage Offset Correction: v_off_ini = 448.191 uV, v_off_fin = 459.361 uV 16:01:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 62.200 uVs 16:01:11 I2X Average and RMS of Measurements VT = -57.934 +- 6.969 uVs I2X = 5.330 +- 0.641 uTm^2 16:01:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:01:16 Integrated Voltage Measurement... 16:01:25 Voltage Offset Correction: v_off_ini = 451.618 uV, v_off_fin = 452.752 uV 16:01:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -403.298 uVs 16:01:25 Integrated Voltage Measurement... 16:01:34 Voltage Offset Correction: v_off_ini = 447.558 uV, v_off_fin = 441.431 uV 16:01:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 410.528 uVs 16:01:34 Integrated Voltage Measurement... 16:01:43 Voltage Offset Correction: v_off_ini = 439.026 uV, v_off_fin = 439.719 uV 16:01:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.347 uVs 16:01:43 Integrated Voltage Measurement... 16:01:52 Voltage Offset Correction: v_off_ini = 441.398 uV, v_off_fin = 437.540 uV 16:01:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 410.808 uVs 16:01:52 Integrated Voltage Measurement... 16:02:01 Voltage Offset Correction: v_off_ini = 447.317 uV, v_off_fin = 435.217 uV 16:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.266 uVs 16:02:01 Integrated Voltage Measurement... 16:02:10 Voltage Offset Correction: v_off_ini = 429.732 uV, v_off_fin = 435.582 uV 16:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 408.769 uVs 16:02:13 I2Y Average and RMS of Measurements VT = -411.836 +- 3.754 uVs I2Y = -37.889 +- 0.345 uTm^2 16:02:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:21 Integrated Voltage Measurement... 16:02:30 Voltage Offset Correction: v_off_ini = 433.197 uV, v_off_fin = 437.089 uV 16:02:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.700 uVs 16:02:30 Integrated Voltage Measurement... 16:02:39 Voltage Offset Correction: v_off_ini = 430.102 uV, v_off_fin = 423.031 uV 16:02:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.955 uVs 16:02:39 Integrated Voltage Measurement... 16:02:48 Voltage Offset Correction: v_off_ini = 434.990 uV, v_off_fin = 432.969 uV 16:02:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.207 uVs 16:02:48 Integrated Voltage Measurement... 16:02:57 Voltage Offset Correction: v_off_ini = 447.596 uV, v_off_fin = 446.358 uV 16:02:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.754 uVs 16:02:57 Integrated Voltage Measurement... 16:03:06 Voltage Offset Correction: v_off_ini = 442.281 uV, v_off_fin = 437.487 uV 16:03:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.768 uVs 16:03:06 Integrated Voltage Measurement... 16:03:15 Voltage Offset Correction: v_off_ini = 424.551 uV, v_off_fin = 411.371 uV 16:03:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.977 uVs 16:03:19 I1X Average and RMS of Measurements VT = -82.894 +- 8.147 uVs I1X = 16.579 +- 1.630 uTm 16:03:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:26 Integrated Voltage Measurement... 16:03:35 Voltage Offset Correction: v_off_ini = 417.212 uV, v_off_fin = 418.700 uV 16:03:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.539 uVs 16:03:35 Integrated Voltage Measurement... 16:03:44 Voltage Offset Correction: v_off_ini = 434.405 uV, v_off_fin = 440.734 uV 16:03:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.463 uVs 16:03:44 Integrated Voltage Measurement... 16:03:53 Voltage Offset Correction: v_off_ini = 429.630 uV, v_off_fin = 408.731 uV 16:03:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.862 uVs 16:03:53 Integrated Voltage Measurement... 16:04:02 Voltage Offset Correction: v_off_ini = 417.784 uV, v_off_fin = 419.997 uV 16:04:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.180 uVs 16:04:02 Integrated Voltage Measurement... 16:04:11 Voltage Offset Correction: v_off_ini = 403.593 uV, v_off_fin = 411.897 uV 16:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.931 uVs 16:04:11 Integrated Voltage Measurement... 16:04:20 Voltage Offset Correction: v_off_ini = 408.982 uV, v_off_fin = 414.156 uV 16:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.129 uVs 16:04:24 I1Y Average and RMS of Measurements VT = -229.017 +- 1.228 uVs I1Y = -45.803 +- 0.246 uTm 16:04:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:29 Integrated Voltage Measurement... 16:04:38 Voltage Offset Correction: v_off_ini = 414.791 uV, v_off_fin = 412.536 uV 16:04:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -68.844 uVs 16:04:38 Integrated Voltage Measurement... 16:04:47 Voltage Offset Correction: v_off_ini = 422.977 uV, v_off_fin = 439.930 uV 16:04:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.348 uVs 16:04:47 Integrated Voltage Measurement... 16:04:56 Voltage Offset Correction: v_off_ini = 409.426 uV, v_off_fin = 407.921 uV 16:04:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -55.286 uVs 16:04:56 Integrated Voltage Measurement... 16:05:05 Voltage Offset Correction: v_off_ini = 406.202 uV, v_off_fin = 407.974 uV 16:05:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.481 uVs 16:05:05 Integrated Voltage Measurement... 16:05:14 Voltage Offset Correction: v_off_ini = 418.550 uV, v_off_fin = 418.770 uV 16:05:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.020 uVs 16:05:14 Integrated Voltage Measurement... 16:05:23 Voltage Offset Correction: v_off_ini = 418.280 uV, v_off_fin = 429.988 uV 16:05:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.531 uVs 16:05:26 I2X Average and RMS of Measurements VT = -66.585 +- 3.010 uVs I2X = 6.126 +- 0.277 uTm^2 16:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:31 Integrated Voltage Measurement... 16:05:40 Voltage Offset Correction: v_off_ini = 431.607 uV, v_off_fin = 431.241 uV 16:05:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -411.682 uVs 16:05:40 Integrated Voltage Measurement... 16:05:49 Voltage Offset Correction: v_off_ini = 430.336 uV, v_off_fin = 425.747 uV 16:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.945 uVs 16:05:49 Integrated Voltage Measurement... 16:05:58 Voltage Offset Correction: v_off_ini = 415.327 uV, v_off_fin = 412.596 uV 16:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -401.492 uVs 16:05:58 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 426.798 uV, v_off_fin = 428.422 uV 16:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 414.662 uVs 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 436.436 uV, v_off_fin = 436.559 uV 16:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -405.773 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 438.042 uV, v_off_fin = 430.304 uV 16:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.745 uVs 16:06:28 I2Y Average and RMS of Measurements VT = -410.883 +- 2.320 uVs I2Y = -37.802 +- 0.213 uTm^2 16:06:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:06:36 Integrated Voltage Measurement... 16:06:45 Voltage Offset Correction: v_off_ini = 430.996 uV, v_off_fin = 428.917 uV 16:06:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.393 uVs 16:06:45 Integrated Voltage Measurement... 16:06:54 Voltage Offset Correction: v_off_ini = 430.117 uV, v_off_fin = 432.693 uV 16:06:54 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 65.075 uVs 16:06:54 Integrated Voltage Measurement... 16:07:03 Voltage Offset Correction: v_off_ini = 440.860 uV, v_off_fin = 430.003 uV 16:07:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.870 uVs 16:07:03 Integrated Voltage Measurement... 16:07:12 Voltage Offset Correction: v_off_ini = 427.607 uV, v_off_fin = 425.421 uV 16:07:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.244 uVs 16:07:12 Integrated Voltage Measurement... 16:07:21 Voltage Offset Correction: v_off_ini = 433.972 uV, v_off_fin = 434.045 uV 16:07:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.110 uVs 16:07:21 Integrated Voltage Measurement... 16:07:30 Voltage Offset Correction: v_off_ini = 434.666 uV, v_off_fin = 438.181 uV 16:07:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.895 uVs 16:07:34 I1X Average and RMS of Measurements VT = -61.764 +- 3.448 uVs I1X = 12.354 +- 0.690 uTm 16:07:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:07:41 Integrated Voltage Measurement... 16:07:50 Voltage Offset Correction: v_off_ini = 438.779 uV, v_off_fin = 410.196 uV 16:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.402 uVs 16:07:50 Integrated Voltage Measurement... 16:07:59 Voltage Offset Correction: v_off_ini = 439.565 uV, v_off_fin = 437.483 uV 16:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.323 uVs 16:07:59 Integrated Voltage Measurement... 16:08:08 Voltage Offset Correction: v_off_ini = 439.566 uV, v_off_fin = 424.291 uV 16:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -235.651 uVs 16:08:08 Integrated Voltage Measurement... 16:08:17 Voltage Offset Correction: v_off_ini = 424.663 uV, v_off_fin = 451.025 uV 16:08:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.043 uVs 16:08:17 Integrated Voltage Measurement... 16:08:26 Voltage Offset Correction: v_off_ini = 448.521 uV, v_off_fin = 417.992 uV 16:08:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -238.968 uVs 16:08:26 Integrated Voltage Measurement... 16:08:35 Voltage Offset Correction: v_off_ini = 420.336 uV, v_off_fin = 446.252 uV 16:08:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.614 uVs 16:08:39 I1Y Average and RMS of Measurements VT = -235.000 +- 4.222 uVs I1Y = -46.995 +- 0.844 uTm 16:08:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:08:44 Integrated Voltage Measurement... 16:08:53 Voltage Offset Correction: v_off_ini = 426.119 uV, v_off_fin = 416.500 uV 16:08:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -88.032 uVs 16:08:53 Integrated Voltage Measurement... 16:09:02 Voltage Offset Correction: v_off_ini = 430.540 uV, v_off_fin = 445.724 uV 16:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.797 uVs 16:09:02 Integrated Voltage Measurement... 16:09:11 Voltage Offset Correction: v_off_ini = 430.092 uV, v_off_fin = 412.952 uV 16:09:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.045 uVs 16:09:11 Integrated Voltage Measurement... 16:09:20 Voltage Offset Correction: v_off_ini = 421.400 uV, v_off_fin = 432.290 uV 16:09:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.109 uVs 16:09:20 Integrated Voltage Measurement... 16:09:29 Voltage Offset Correction: v_off_ini = 438.047 uV, v_off_fin = 419.275 uV 16:09:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.462 uVs 16:09:29 Integrated Voltage Measurement... 16:09:38 Voltage Offset Correction: v_off_ini = 435.887 uV, v_off_fin = 436.405 uV 16:09:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.956 uVs 16:09:41 I2X Average and RMS of Measurements VT = -72.400 +- 6.517 uVs I2X = 6.661 +- 0.600 uTm^2 16:09:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:09:46 Integrated Voltage Measurement... 16:09:55 Voltage Offset Correction: v_off_ini = 431.376 uV, v_off_fin = 436.276 uV 16:09:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -413.860 uVs 16:09:55 Integrated Voltage Measurement... 16:10:04 Voltage Offset Correction: v_off_ini = 433.254 uV, v_off_fin = 441.822 uV 16:10:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 420.285 uVs 16:10:04 Integrated Voltage Measurement... 16:10:13 Voltage Offset Correction: v_off_ini = 434.311 uV, v_off_fin = 436.450 uV 16:10:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.340 uVs 16:10:13 Integrated Voltage Measurement... 16:10:22 Voltage Offset Correction: v_off_ini = 438.662 uV, v_off_fin = 425.359 uV 16:10:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 430.802 uVs 16:10:22 Integrated Voltage Measurement... 16:10:31 Voltage Offset Correction: v_off_ini = 430.841 uV, v_off_fin = 437.036 uV 16:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.341 uVs 16:10:31 Integrated Voltage Measurement... 16:10:40 Voltage Offset Correction: v_off_ini = 438.189 uV, v_off_fin = 442.766 uV 16:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 398.585 uVs 16:10:42 I2Y Average and RMS of Measurements VT = -417.702 +- 16.380 uVs I2Y = -38.429 +- 1.507 uTm^2 16:10:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:10:51 Integrated Voltage Measurement... 16:11:00 Voltage Offset Correction: v_off_ini = 423.556 uV, v_off_fin = 437.247 uV 16:11:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -63.501 uVs 16:11:00 Integrated Voltage Measurement... 16:11:09 Voltage Offset Correction: v_off_ini = 428.737 uV, v_off_fin = 428.888 uV 16:11:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.097 uVs 16:11:09 Integrated Voltage Measurement... 16:11:18 Voltage Offset Correction: v_off_ini = 408.647 uV, v_off_fin = 417.869 uV 16:11:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.035 uVs 16:11:18 Integrated Voltage Measurement... 16:11:27 Voltage Offset Correction: v_off_ini = 411.866 uV, v_off_fin = 422.945 uV 16:11:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.282 uVs 16:11:27 Integrated Voltage Measurement... 16:11:36 Voltage Offset Correction: v_off_ini = 423.656 uV, v_off_fin = 425.275 uV 16:11:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.500 uVs 16:11:36 Integrated Voltage Measurement... 16:11:45 Voltage Offset Correction: v_off_ini = 426.285 uV, v_off_fin = 437.633 uV 16:11:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.099 uVs 16:11:49 I1X Average and RMS of Measurements VT = -73.086 +- 5.163 uVs I1X = 14.618 +- 1.032 uTm 16:11:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:11:56 Integrated Voltage Measurement... 16:12:05 Voltage Offset Correction: v_off_ini = 448.334 uV, v_off_fin = 437.121 uV 16:12:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.952 uVs 16:12:05 Integrated Voltage Measurement... 16:12:14 Voltage Offset Correction: v_off_ini = 432.277 uV, v_off_fin = 442.014 uV 16:12:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.599 uVs 16:12:14 Integrated Voltage Measurement... 16:12:23 Voltage Offset Correction: v_off_ini = 432.158 uV, v_off_fin = 420.497 uV 16:12:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -252.079 uVs 16:12:23 Integrated Voltage Measurement... 16:12:32 Voltage Offset Correction: v_off_ini = 441.748 uV, v_off_fin = 446.616 uV 16:12:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.906 uVs 16:12:32 Integrated Voltage Measurement... 16:12:41 Voltage Offset Correction: v_off_ini = 425.252 uV, v_off_fin = 411.459 uV 16:12:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.877 uVs 16:12:41 Integrated Voltage Measurement... 16:12:50 Voltage Offset Correction: v_off_ini = 427.724 uV, v_off_fin = 441.753 uV 16:12:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.931 uVs 16:12:54 I1Y Average and RMS of Measurements VT = -239.724 +- 10.503 uVs I1Y = -47.942 +- 2.101 uTm 16:12:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:12:59 Integrated Voltage Measurement... 16:13:08 Voltage Offset Correction: v_off_ini = 428.419 uV, v_off_fin = 420.093 uV 16:13:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.604 uVs 16:13:08 Integrated Voltage Measurement... 16:13:17 Voltage Offset Correction: v_off_ini = 429.611 uV, v_off_fin = 434.255 uV 16:13:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.708 uVs 16:13:17 Integrated Voltage Measurement... 16:13:26 Voltage Offset Correction: v_off_ini = 416.135 uV, v_off_fin = 420.160 uV 16:13:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.599 uVs 16:13:26 Integrated Voltage Measurement... 16:13:35 Voltage Offset Correction: v_off_ini = 419.255 uV, v_off_fin = 442.323 uV 16:13:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.823 uVs 16:13:35 Integrated Voltage Measurement... 16:13:44 Voltage Offset Correction: v_off_ini = 434.034 uV, v_off_fin = 417.100 uV 16:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.166 uVs 16:13:44 Integrated Voltage Measurement... 16:13:53 Voltage Offset Correction: v_off_ini = 428.755 uV, v_off_fin = 431.195 uV 16:13:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.949 uVs 16:13:56 I2X Average and RMS of Measurements VT = -74.808 +- 7.007 uVs I2X = 6.882 +- 0.645 uTm^2 16:13:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:14:01 Integrated Voltage Measurement... 16:14:10 Voltage Offset Correction: v_off_ini = 425.586 uV, v_off_fin = 415.651 uV 16:14:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.979 uVs 16:14:10 Integrated Voltage Measurement... 16:14:19 Voltage Offset Correction: v_off_ini = 421.559 uV, v_off_fin = 416.121 uV 16:14:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.881 uVs 16:14:19 Integrated Voltage Measurement... 16:14:28 Voltage Offset Correction: v_off_ini = 411.236 uV, v_off_fin = 421.070 uV 16:14:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.562 uVs 16:14:28 Integrated Voltage Measurement... 16:14:37 Voltage Offset Correction: v_off_ini = 429.467 uV, v_off_fin = 422.744 uV 16:14:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 422.540 uVs 16:14:37 Integrated Voltage Measurement... 16:14:46 Voltage Offset Correction: v_off_ini = 424.005 uV, v_off_fin = 423.150 uV 16:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -420.765 uVs 16:14:46 Integrated Voltage Measurement... 16:14:55 Voltage Offset Correction: v_off_ini = 412.863 uV, v_off_fin = 422.359 uV 16:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.081 uVs 16:14:58 I2Y Average and RMS of Measurements VT = -422.968 +- 1.637 uVs I2Y = -38.913 +- 0.151 uTm^2 16:15:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:15:19 Integrated Voltage Measurement... 16:15:28 Voltage Offset Correction: v_off_ini = 442.228 uV, v_off_fin = 423.575 uV 16:15:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.138 uVs 16:15:28 Integrated Voltage Measurement... 16:15:37 Voltage Offset Correction: v_off_ini = 426.330 uV, v_off_fin = 426.910 uV 16:15:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.905 uVs 16:15:37 Integrated Voltage Measurement... 16:15:46 Voltage Offset Correction: v_off_ini = 438.261 uV, v_off_fin = 433.100 uV 16:15:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.021 uVs 16:15:46 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = 435.840 uV, v_off_fin = 426.964 uV 16:15:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.027 uVs 16:15:55 Integrated Voltage Measurement... 16:16:04 Voltage Offset Correction: v_off_ini = 420.675 uV, v_off_fin = 411.977 uV 16:16:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.031 uVs 16:16:04 Integrated Voltage Measurement... 16:16:13 Voltage Offset Correction: v_off_ini = 402.149 uV, v_off_fin = 409.352 uV 16:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.853 uVs 16:16:17 I1X Average and RMS of Measurements VT = -84.829 +- 2.816 uVs I1X = 16.967 +- 0.564 uTm 16:16:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:16:24 Integrated Voltage Measurement... 16:16:33 Voltage Offset Correction: v_off_ini = 420.191 uV, v_off_fin = 400.076 uV 16:16:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.442 uVs 16:16:33 Integrated Voltage Measurement... 16:16:42 Voltage Offset Correction: v_off_ini = 421.525 uV, v_off_fin = 431.608 uV 16:16:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.774 uVs 16:16:42 Integrated Voltage Measurement... 16:16:51 Voltage Offset Correction: v_off_ini = 425.967 uV, v_off_fin = 412.445 uV 16:16:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.262 uVs 16:16:51 Integrated Voltage Measurement... 16:17:00 Voltage Offset Correction: v_off_ini = 413.039 uV, v_off_fin = 421.480 uV 16:17:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.929 uVs 16:17:00 Integrated Voltage Measurement... 16:17:09 Voltage Offset Correction: v_off_ini = 427.568 uV, v_off_fin = 405.396 uV 16:17:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -227.321 uVs 16:17:09 Integrated Voltage Measurement... 16:17:18 Voltage Offset Correction: v_off_ini = 419.689 uV, v_off_fin = 432.123 uV 16:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.777 uVs 16:17:22 I1Y Average and RMS of Measurements VT = -218.251 +- 2.320 uVs I1Y = -43.651 +- 0.464 uTm 16:17:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:17:30 Integrated Voltage Measurement... 16:17:39 Voltage Offset Correction: v_off_ini = 431.946 uV, v_off_fin = 418.787 uV 16:17:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.133 uVs 16:17:39 Integrated Voltage Measurement... 16:17:48 Voltage Offset Correction: v_off_ini = 427.925 uV, v_off_fin = 428.296 uV 16:17:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.926 uVs 16:17:48 Integrated Voltage Measurement... 16:17:57 Voltage Offset Correction: v_off_ini = 434.519 uV, v_off_fin = 423.691 uV 16:17:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.125 uVs 16:17:57 Integrated Voltage Measurement... 16:18:06 Voltage Offset Correction: v_off_ini = 408.147 uV, v_off_fin = 418.949 uV 16:18:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.270 uVs 16:18:06 Integrated Voltage Measurement... 16:18:15 Voltage Offset Correction: v_off_ini = 424.164 uV, v_off_fin = 411.727 uV 16:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.736 uVs 16:18:15 Integrated Voltage Measurement... 16:18:24 Voltage Offset Correction: v_off_ini = 425.640 uV, v_off_fin = 433.971 uV 16:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.885 uVs 16:18:26 I2X Average and RMS of Measurements VT = -85.846 +- 7.207 uVs I2X = 7.898 +- 0.663 uTm^2 16:18:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:18:34 Integrated Voltage Measurement... 16:18:43 Voltage Offset Correction: v_off_ini = 428.928 uV, v_off_fin = 420.409 uV 16:18:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -386.487 uVs 16:18:43 Integrated Voltage Measurement... 16:18:52 Voltage Offset Correction: v_off_ini = 427.934 uV, v_off_fin = 415.751 uV 16:18:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.252 uVs 16:18:52 Integrated Voltage Measurement... 16:19:01 Voltage Offset Correction: v_off_ini = 413.682 uV, v_off_fin = 410.069 uV 16:19:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.157 uVs 16:19:01 Integrated Voltage Measurement... 16:19:10 Voltage Offset Correction: v_off_ini = 414.974 uV, v_off_fin = 416.746 uV 16:19:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.518 uVs 16:19:10 Integrated Voltage Measurement... 16:19:19 Voltage Offset Correction: v_off_ini = 419.101 uV, v_off_fin = 422.367 uV 16:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -366.046 uVs 16:19:19 Integrated Voltage Measurement... 16:19:28 Voltage Offset Correction: v_off_ini = 430.192 uV, v_off_fin = 410.764 uV 16:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.062 uVs 16:19:31 I2Y Average and RMS of Measurements VT = -378.920 +- 2.456 uVs I2Y = -34.861 +- 0.226 uTm^2 16:19:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:19:40 Integrated Voltage Measurement... 16:19:49 Voltage Offset Correction: v_off_ini = 412.050 uV, v_off_fin = 413.953 uV 16:19:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.456 uVs 16:19:49 Integrated Voltage Measurement... 16:19:58 Voltage Offset Correction: v_off_ini = 418.328 uV, v_off_fin = 423.084 uV 16:19:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.965 uVs 16:19:58 Integrated Voltage Measurement... 16:20:07 Voltage Offset Correction: v_off_ini = 410.603 uV, v_off_fin = 412.939 uV 16:20:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.457 uVs 16:20:07 Integrated Voltage Measurement... 16:20:16 Voltage Offset Correction: v_off_ini = 415.963 uV, v_off_fin = 405.778 uV 16:20:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.575 uVs 16:20:16 Integrated Voltage Measurement... 16:20:25 Voltage Offset Correction: v_off_ini = 408.735 uV, v_off_fin = 417.706 uV 16:20:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.736 uVs 16:20:25 Integrated Voltage Measurement... 16:20:34 Voltage Offset Correction: v_off_ini = 405.608 uV, v_off_fin = 422.080 uV 16:20:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.755 uVs 16:20:38 I1X Average and RMS of Measurements VT = -93.824 +- 8.830 uVs I1X = 18.765 +- 1.766 uTm 16:20:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:20:45 Integrated Voltage Measurement... 16:20:54 Voltage Offset Correction: v_off_ini = 416.135 uV, v_off_fin = 391.907 uV 16:20:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.961 uVs 16:20:54 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 403.785 uV, v_off_fin = 421.059 uV 16:21:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.994 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = 399.171 uV, v_off_fin = 390.863 uV 16:21:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.666 uVs 16:21:12 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = 409.548 uV, v_off_fin = 410.645 uV 16:21:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.555 uVs 16:21:21 Integrated Voltage Measurement... 16:21:30 Voltage Offset Correction: v_off_ini = 404.770 uV, v_off_fin = 414.012 uV 16:21:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.192 uVs 16:21:30 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = 408.677 uV, v_off_fin = 416.137 uV 16:21:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.533 uVs 16:21:43 I1Y Average and RMS of Measurements VT = -211.650 +- 3.798 uVs I1Y = -42.330 +- 0.760 uTm 16:21:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:21:51 Integrated Voltage Measurement... 16:22:00 Voltage Offset Correction: v_off_ini = 386.601 uV, v_off_fin = 391.572 uV 16:22:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.892 uVs 16:22:00 Integrated Voltage Measurement... 16:22:09 Voltage Offset Correction: v_off_ini = 396.624 uV, v_off_fin = 408.062 uV 16:22:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.694 uVs 16:22:09 Integrated Voltage Measurement... 16:22:18 Voltage Offset Correction: v_off_ini = 393.592 uV, v_off_fin = 400.870 uV 16:22:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.846 uVs 16:22:18 Integrated Voltage Measurement... 16:22:27 Voltage Offset Correction: v_off_ini = 398.028 uV, v_off_fin = 398.150 uV 16:22:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.593 uVs 16:22:27 Integrated Voltage Measurement... 16:22:36 Voltage Offset Correction: v_off_ini = 380.859 uV, v_off_fin = 384.920 uV 16:22:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.016 uVs 16:22:36 Integrated Voltage Measurement... 16:22:45 Voltage Offset Correction: v_off_ini = 386.625 uV, v_off_fin = 403.632 uV 16:22:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.478 uVs 16:22:47 I2X Average and RMS of Measurements VT = -83.753 +- 6.042 uVs I2X = 7.705 +- 0.556 uTm^2 16:22:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:22:55 Integrated Voltage Measurement... 16:23:04 Voltage Offset Correction: v_off_ini = 392.711 uV, v_off_fin = 390.209 uV 16:23:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.994 uVs 16:23:04 Integrated Voltage Measurement... 16:23:13 Voltage Offset Correction: v_off_ini = 405.328 uV, v_off_fin = 405.558 uV 16:23:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.359 uVs 16:23:13 Integrated Voltage Measurement... 16:23:22 Voltage Offset Correction: v_off_ini = 403.724 uV, v_off_fin = 405.461 uV 16:23:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.254 uVs 16:23:22 Integrated Voltage Measurement... 16:23:31 Voltage Offset Correction: v_off_ini = 405.560 uV, v_off_fin = 409.183 uV 16:23:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.319 uVs 16:23:31 Integrated Voltage Measurement... 16:23:40 Voltage Offset Correction: v_off_ini = 407.651 uV, v_off_fin = 395.874 uV 16:23:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.127 uVs 16:23:40 Integrated Voltage Measurement... 16:23:49 Voltage Offset Correction: v_off_ini = 405.202 uV, v_off_fin = 397.169 uV 16:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.139 uVs 16:23:51 I2Y Average and RMS of Measurements VT = -374.032 +- 10.934 uVs I2Y = -34.411 +- 1.006 uTm^2 16:23:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:00 Integrated Voltage Measurement... 16:24:09 Voltage Offset Correction: v_off_ini = 405.808 uV, v_off_fin = 380.979 uV 16:24:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.384 uVs 16:24:09 Integrated Voltage Measurement... 16:24:18 Voltage Offset Correction: v_off_ini = 386.109 uV, v_off_fin = 405.499 uV 16:24:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.699 uVs 16:24:18 Integrated Voltage Measurement... 16:24:27 Voltage Offset Correction: v_off_ini = 409.543 uV, v_off_fin = 388.915 uV 16:24:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.406 uVs 16:24:27 Integrated Voltage Measurement... 16:24:36 Voltage Offset Correction: v_off_ini = 399.741 uV, v_off_fin = 404.710 uV 16:24:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.595 uVs 16:24:36 Integrated Voltage Measurement... 16:24:45 Voltage Offset Correction: v_off_ini = 405.478 uV, v_off_fin = 397.725 uV 16:24:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.073 uVs 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = 402.557 uV, v_off_fin = 399.002 uV 16:24:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.641 uVs 16:24:58 I1X Average and RMS of Measurements VT = -98.633 +- 5.215 uVs I1X = 19.727 +- 1.043 uTm 16:25:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:05 Integrated Voltage Measurement... 16:25:14 Voltage Offset Correction: v_off_ini = 391.332 uV, v_off_fin = 386.085 uV 16:25:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.281 uVs 16:25:14 Integrated Voltage Measurement... 16:25:23 Voltage Offset Correction: v_off_ini = 398.399 uV, v_off_fin = 419.042 uV 16:25:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.569 uVs 16:25:23 Integrated Voltage Measurement... 16:25:32 Voltage Offset Correction: v_off_ini = 401.475 uV, v_off_fin = 394.525 uV 16:25:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.813 uVs 16:25:32 Integrated Voltage Measurement... 16:25:41 Voltage Offset Correction: v_off_ini = 406.656 uV, v_off_fin = 414.663 uV 16:25:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.071 uVs 16:25:41 Integrated Voltage Measurement... 16:25:50 Voltage Offset Correction: v_off_ini = 390.676 uV, v_off_fin = 401.784 uV 16:25:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.493 uVs 16:25:50 Integrated Voltage Measurement... 16:25:59 Voltage Offset Correction: v_off_ini = 404.266 uV, v_off_fin = 419.159 uV 16:25:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.558 uVs 16:26:03 I1Y Average and RMS of Measurements VT = -188.298 +- 2.941 uVs I1Y = -37.660 +- 0.588 uTm 16:26:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = 392.347 uV, v_off_fin = 402.076 uV 16:26:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -95.329 uVs 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = 397.533 uV, v_off_fin = 402.979 uV 16:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.435 uVs 16:26:29 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = 383.617 uV, v_off_fin = 383.686 uV 16:26:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.625 uVs 16:26:38 Integrated Voltage Measurement... 16:26:47 Voltage Offset Correction: v_off_ini = 398.004 uV, v_off_fin = 397.206 uV 16:26:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.821 uVs 16:26:47 Integrated Voltage Measurement... 16:26:56 Voltage Offset Correction: v_off_ini = 393.583 uV, v_off_fin = 388.241 uV 16:26:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.259 uVs 16:26:56 Integrated Voltage Measurement... 16:27:05 Voltage Offset Correction: v_off_ini = 413.029 uV, v_off_fin = 403.638 uV 16:27:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.202 uVs 16:27:07 I2X Average and RMS of Measurements VT = -91.945 +- 3.844 uVs I2X = 8.459 +- 0.353 uTm^2 16:27:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:15 Integrated Voltage Measurement... 16:27:24 Voltage Offset Correction: v_off_ini = 402.784 uV, v_off_fin = 403.809 uV 16:27:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.672 uVs 16:27:24 Integrated Voltage Measurement... 16:27:33 Voltage Offset Correction: v_off_ini = 406.720 uV, v_off_fin = 413.160 uV 16:27:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 353.391 uVs 16:27:33 Integrated Voltage Measurement... 16:27:42 Voltage Offset Correction: v_off_ini = 399.992 uV, v_off_fin = 401.647 uV 16:27:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.426 uVs 16:27:42 Integrated Voltage Measurement... 16:27:51 Voltage Offset Correction: v_off_ini = 389.400 uV, v_off_fin = 400.604 uV 16:27:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.089 uVs 16:27:51 Integrated Voltage Measurement... 16:28:00 Voltage Offset Correction: v_off_ini = 388.314 uV, v_off_fin = 392.583 uV 16:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.698 uVs 16:28:00 Integrated Voltage Measurement... 16:28:09 Voltage Offset Correction: v_off_ini = 398.996 uV, v_off_fin = 400.986 uV 16:28:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.234 uVs 16:28:12 I2Y Average and RMS of Measurements VT = -356.918 +- 4.817 uVs I2Y = -32.837 +- 0.444 uTm^2 16:28:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:28:20 Integrated Voltage Measurement... 16:28:29 Voltage Offset Correction: v_off_ini = 402.565 uV, v_off_fin = 391.137 uV 16:28:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -90.707 uVs 16:28:30 Integrated Voltage Measurement... 16:28:38 Voltage Offset Correction: v_off_ini = 392.419 uV, v_off_fin = 396.436 uV 16:28:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.854 uVs 16:28:39 Integrated Voltage Measurement... 16:28:47 Voltage Offset Correction: v_off_ini = 394.712 uV, v_off_fin = 385.803 uV 16:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.185 uVs 16:28:48 Integrated Voltage Measurement... 16:28:56 Voltage Offset Correction: v_off_ini = 391.460 uV, v_off_fin = 391.183 uV 16:28:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.994 uVs 16:28:57 Integrated Voltage Measurement... 16:29:05 Voltage Offset Correction: v_off_ini = 400.773 uV, v_off_fin = 392.421 uV 16:29:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.571 uVs 16:29:06 Integrated Voltage Measurement... 16:29:14 Voltage Offset Correction: v_off_ini = 393.202 uV, v_off_fin = 405.010 uV 16:29:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.950 uVs 16:29:19 I1X Average and RMS of Measurements VT = -98.377 +- 2.536 uVs I1X = 19.676 +- 0.507 uTm 16:29:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:29:25 Integrated Voltage Measurement... 16:29:34 Voltage Offset Correction: v_off_ini = 399.485 uV, v_off_fin = 377.727 uV 16:29:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.820 uVs 16:29:34 Integrated Voltage Measurement... 16:29:43 Voltage Offset Correction: v_off_ini = 385.868 uV, v_off_fin = 395.847 uV 16:29:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.160 uVs 16:29:43 Integrated Voltage Measurement... 16:29:52 Voltage Offset Correction: v_off_ini = 382.249 uV, v_off_fin = 384.850 uV 16:29:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.136 uVs 16:29:52 Integrated Voltage Measurement... 16:30:01 Voltage Offset Correction: v_off_ini = 391.365 uV, v_off_fin = 410.717 uV 16:30:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.591 uVs 16:30:01 Integrated Voltage Measurement... 16:30:10 Voltage Offset Correction: v_off_ini = 390.349 uV, v_off_fin = 374.488 uV 16:30:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.567 uVs 16:30:10 Integrated Voltage Measurement... 16:30:19 Voltage Offset Correction: v_off_ini = 376.224 uV, v_off_fin = 384.071 uV 16:30:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.343 uVs 16:30:24 I1Y Average and RMS of Measurements VT = -181.436 +- 7.606 uVs I1Y = -36.287 +- 1.521 uTm 16:30:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:30:31 Integrated Voltage Measurement... 16:30:40 Voltage Offset Correction: v_off_ini = 379.592 uV, v_off_fin = 366.651 uV 16:30:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.182 uVs 16:30:40 Integrated Voltage Measurement... 16:30:49 Voltage Offset Correction: v_off_ini = 378.166 uV, v_off_fin = 379.021 uV 16:30:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.484 uVs 16:30:49 Integrated Voltage Measurement... 16:30:58 Voltage Offset Correction: v_off_ini = 378.136 uV, v_off_fin = 381.490 uV 16:30:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.077 uVs 16:30:58 Integrated Voltage Measurement... 16:31:07 Voltage Offset Correction: v_off_ini = 372.972 uV, v_off_fin = 391.491 uV 16:31:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.566 uVs 16:31:07 Integrated Voltage Measurement... 16:31:16 Voltage Offset Correction: v_off_ini = 372.077 uV, v_off_fin = 375.811 uV 16:31:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.775 uVs 16:31:16 Integrated Voltage Measurement... 16:31:25 Voltage Offset Correction: v_off_ini = 387.191 uV, v_off_fin = 383.612 uV 16:31:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.329 uVs 16:31:28 I2X Average and RMS of Measurements VT = -94.069 +- 3.747 uVs I2X = 8.654 +- 0.345 uTm^2 16:31:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:31:35 Integrated Voltage Measurement... 16:31:44 Voltage Offset Correction: v_off_ini = 394.955 uV, v_off_fin = 387.713 uV 16:31:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.606 uVs 16:31:44 Integrated Voltage Measurement... 16:31:53 Voltage Offset Correction: v_off_ini = 391.463 uV, v_off_fin = 391.152 uV 16:31:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.914 uVs 16:31:53 Integrated Voltage Measurement... 16:32:02 Voltage Offset Correction: v_off_ini = 393.757 uV, v_off_fin = 392.508 uV 16:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.307 uVs 16:32:02 Integrated Voltage Measurement... 16:32:11 Voltage Offset Correction: v_off_ini = 391.333 uV, v_off_fin = 393.980 uV 16:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.919 uVs 16:32:12 Integrated Voltage Measurement... 16:32:20 Voltage Offset Correction: v_off_ini = 396.509 uV, v_off_fin = 388.229 uV 16:32:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.083 uVs 16:32:21 Integrated Voltage Measurement... 16:32:30 Voltage Offset Correction: v_off_ini = 388.284 uV, v_off_fin = 402.048 uV 16:32:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.695 uVs 16:32:32 I2Y Average and RMS of Measurements VT = -345.754 +- 5.989 uVs I2Y = -31.809 +- 0.551 uTm^2 16:32:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:32:41 Integrated Voltage Measurement... 16:32:50 Voltage Offset Correction: v_off_ini = 409.535 uV, v_off_fin = 398.746 uV 16:32:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -127.470 uVs 16:32:50 Integrated Voltage Measurement... 16:32:59 Voltage Offset Correction: v_off_ini = 406.241 uV, v_off_fin = 406.257 uV 16:32:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.388 uVs 16:32:59 Integrated Voltage Measurement... 16:33:08 Voltage Offset Correction: v_off_ini = 400.989 uV, v_off_fin = 374.281 uV 16:33:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.545 uVs 16:33:08 Integrated Voltage Measurement... 16:33:17 Voltage Offset Correction: v_off_ini = 378.662 uV, v_off_fin = 370.753 uV 16:33:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.319 uVs 16:33:17 Integrated Voltage Measurement... 16:33:26 Voltage Offset Correction: v_off_ini = 383.367 uV, v_off_fin = 377.255 uV 16:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.649 uVs 16:33:26 Integrated Voltage Measurement... 16:33:35 Voltage Offset Correction: v_off_ini = 387.210 uV, v_off_fin = 383.246 uV 16:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.165 uVs 16:33:39 I1X Average and RMS of Measurements VT = -111.923 +- 7.264 uVs I1X = 22.385 +- 1.454 uTm 16:33:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:33:46 Integrated Voltage Measurement... 16:33:55 Voltage Offset Correction: v_off_ini = 374.763 uV, v_off_fin = 388.919 uV 16:33:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.003 uVs 16:33:55 Integrated Voltage Measurement... 16:34:04 Voltage Offset Correction: v_off_ini = 388.774 uV, v_off_fin = 404.942 uV 16:34:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.271 uVs 16:34:04 Integrated Voltage Measurement... 16:34:13 Voltage Offset Correction: v_off_ini = 396.979 uV, v_off_fin = 376.195 uV 16:34:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.709 uVs 16:34:13 Integrated Voltage Measurement... 16:34:22 Voltage Offset Correction: v_off_ini = 380.036 uV, v_off_fin = 395.147 uV 16:34:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.278 uVs 16:34:22 Integrated Voltage Measurement... 16:34:31 Voltage Offset Correction: v_off_ini = 382.806 uV, v_off_fin = 381.292 uV 16:34:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.798 uVs 16:34:31 Integrated Voltage Measurement... 16:34:40 Voltage Offset Correction: v_off_ini = 390.177 uV, v_off_fin = 387.302 uV 16:34:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.315 uVs 16:34:44 I1Y Average and RMS of Measurements VT = -160.729 +- 6.560 uVs I1Y = -32.146 +- 1.312 uTm 16:34:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:34:52 Integrated Voltage Measurement... 16:35:01 Voltage Offset Correction: v_off_ini = 382.562 uV, v_off_fin = 378.712 uV 16:35:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.410 uVs 16:35:01 Integrated Voltage Measurement... 16:35:10 Voltage Offset Correction: v_off_ini = 379.581 uV, v_off_fin = 395.752 uV 16:35:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.495 uVs 16:35:10 Integrated Voltage Measurement... 16:35:19 Voltage Offset Correction: v_off_ini = 380.995 uV, v_off_fin = 364.517 uV 16:35:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.705 uVs 16:35:19 Integrated Voltage Measurement... 16:35:28 Voltage Offset Correction: v_off_ini = 384.528 uV, v_off_fin = 395.821 uV 16:35:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.870 uVs 16:35:28 Integrated Voltage Measurement... 16:35:37 Voltage Offset Correction: v_off_ini = 395.065 uV, v_off_fin = 383.662 uV 16:35:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.929 uVs 16:35:37 Integrated Voltage Measurement... 16:35:46 Voltage Offset Correction: v_off_ini = 386.257 uV, v_off_fin = 399.055 uV 16:35:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.740 uVs 16:35:48 I2X Average and RMS of Measurements VT = -108.858 +- 4.419 uVs I2X = 10.015 +- 0.407 uTm^2 16:35:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 383.985 uV, v_off_fin = 383.980 uV 16:36:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.046 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 406.946 uV, v_off_fin = 401.629 uV 16:36:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.366 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 393.810 uV, v_off_fin = 403.476 uV 16:36:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.042 uVs 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 393.059 uV, v_off_fin = 397.359 uV 16:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.004 uVs 16:36:32 Integrated Voltage Measurement... 16:36:41 Voltage Offset Correction: v_off_ini = 397.402 uV, v_off_fin = 386.543 uV 16:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.886 uVs 16:36:41 Integrated Voltage Measurement... 16:36:50 Voltage Offset Correction: v_off_ini = 396.365 uV, v_off_fin = 385.539 uV 16:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.061 uVs 16:36:52 I2Y Average and RMS of Measurements VT = -319.901 +- 5.620 uVs I2Y = -29.431 +- 0.517 uTm^2 16:37:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:37:04 Integrated Voltage Measurement... 16:37:13 Voltage Offset Correction: v_off_ini = 383.129 uV, v_off_fin = 378.699 uV 16:37:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4997 mm dXY = -0.4999 mm VT = -67.674 uVs 16:37:13 Integrated Voltage Measurement... 16:37:22 Voltage Offset Correction: v_off_ini = 386.781 uV, v_off_fin = 387.016 uV 16:37:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.207 uVs 16:37:22 Integrated Voltage Measurement... 16:37:31 Voltage Offset Correction: v_off_ini = 392.998 uV, v_off_fin = 410.562 uV 16:37:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.270 uVs 16:37:31 Integrated Voltage Measurement... 16:37:40 Voltage Offset Correction: v_off_ini = 393.970 uV, v_off_fin = 403.996 uV 16:37:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 70.090 uVs 16:37:41 Integrated Voltage Measurement... 16:37:49 Voltage Offset Correction: v_off_ini = 402.320 uV, v_off_fin = 397.435 uV 16:37:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.570 uVs 16:37:50 Integrated Voltage Measurement... 16:37:58 Voltage Offset Correction: v_off_ini = 398.996 uV, v_off_fin = 390.362 uV 16:37:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.312 uVs 16:38:03 I1X Average and RMS of Measurements VT = -69.354 +- 4.661 uVs I1X = 13.872 +- 0.932 uTm 16:38:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:38:10 Integrated Voltage Measurement... 16:38:18 Voltage Offset Correction: v_off_ini = 395.282 uV, v_off_fin = 374.218 uV 16:38:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.907 uVs 16:38:19 Integrated Voltage Measurement... 16:38:27 Voltage Offset Correction: v_off_ini = 395.040 uV, v_off_fin = 390.210 uV 16:38:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.966 uVs 16:38:28 Integrated Voltage Measurement... 16:38:36 Voltage Offset Correction: v_off_ini = 395.746 uV, v_off_fin = 380.790 uV 16:38:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.713 uVs 16:38:37 Integrated Voltage Measurement... 16:38:45 Voltage Offset Correction: v_off_ini = 384.237 uV, v_off_fin = 395.584 uV 16:38:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.353 uVs 16:38:46 Integrated Voltage Measurement... 16:38:54 Voltage Offset Correction: v_off_ini = 386.245 uV, v_off_fin = 388.104 uV 16:38:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.806 uVs 16:38:55 Integrated Voltage Measurement... 16:39:03 Voltage Offset Correction: v_off_ini = 396.610 uV, v_off_fin = 387.056 uV 16:39:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.168 uVs 16:39:08 I1Y Average and RMS of Measurements VT = -185.819 +- 7.596 uVs I1Y = -37.164 +- 1.519 uTm 16:39:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:39:13 Integrated Voltage Measurement... 16:39:22 Voltage Offset Correction: v_off_ini = 377.987 uV, v_off_fin = 375.192 uV 16:39:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.399 uVs 16:39:22 Integrated Voltage Measurement... 16:39:31 Voltage Offset Correction: v_off_ini = 382.493 uV, v_off_fin = 375.859 uV 16:39:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.900 uVs 16:39:31 Integrated Voltage Measurement... 16:39:40 Voltage Offset Correction: v_off_ini = 376.001 uV, v_off_fin = 364.519 uV 16:39:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.520 uVs 16:39:40 Integrated Voltage Measurement... 16:39:49 Voltage Offset Correction: v_off_ini = 368.196 uV, v_off_fin = 381.435 uV 16:39:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.140 uVs 16:39:49 Integrated Voltage Measurement... 16:39:58 Voltage Offset Correction: v_off_ini = 375.492 uV, v_off_fin = 363.192 uV 16:39:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.289 uVs 16:39:58 Integrated Voltage Measurement... 16:40:07 Voltage Offset Correction: v_off_ini = 380.949 uV, v_off_fin = 379.005 uV 16:40:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.146 uVs 16:40:09 I2X Average and RMS of Measurements VT = -63.399 +- 3.932 uVs I2X = 5.833 +- 0.362 uTm^2 16:40:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:40:15 Integrated Voltage Measurement... 16:40:24 Voltage Offset Correction: v_off_ini = 359.199 uV, v_off_fin = 361.284 uV 16:40:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.407 uVs 16:40:24 Integrated Voltage Measurement... 16:40:33 Voltage Offset Correction: v_off_ini = 366.457 uV, v_off_fin = 367.769 uV 16:40:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.530 uVs 16:40:33 Integrated Voltage Measurement... 16:40:42 Voltage Offset Correction: v_off_ini = 367.958 uV, v_off_fin = 356.712 uV 16:40:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.838 uVs 16:40:42 Integrated Voltage Measurement... 16:40:51 Voltage Offset Correction: v_off_ini = 360.125 uV, v_off_fin = 368.803 uV 16:40:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.413 uVs 16:40:51 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = 365.581 uV, v_off_fin = 367.350 uV 16:41:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.403 uVs 16:41:00 Integrated Voltage Measurement... 16:41:09 Voltage Offset Correction: v_off_ini = 369.295 uV, v_off_fin = 367.769 uV 16:41:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.745 uVs 16:41:11 I2Y Average and RMS of Measurements VT = -355.222 +- 5.159 uVs I2Y = -32.680 +- 0.475 uTm^2 16:41:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:41:19 Integrated Voltage Measurement... 16:41:28 Voltage Offset Correction: v_off_ini = 369.268 uV, v_off_fin = 370.980 uV 16:41:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.843 uVs 16:41:28 Integrated Voltage Measurement... 16:41:37 Voltage Offset Correction: v_off_ini = 367.941 uV, v_off_fin = 379.021 uV 16:41:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.028 uVs 16:41:37 Integrated Voltage Measurement... 16:41:46 Voltage Offset Correction: v_off_ini = 387.556 uV, v_off_fin = 378.442 uV 16:41:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.352 uVs 16:41:46 Integrated Voltage Measurement... 16:41:55 Voltage Offset Correction: v_off_ini = 363.173 uV, v_off_fin = 378.059 uV 16:41:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.588 uVs 16:41:55 Integrated Voltage Measurement... 16:42:04 Voltage Offset Correction: v_off_ini = 374.160 uV, v_off_fin = 380.279 uV 16:42:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.763 uVs 16:42:04 Integrated Voltage Measurement... 16:42:13 Voltage Offset Correction: v_off_ini = 377.166 uV, v_off_fin = 371.194 uV 16:42:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.887 uVs 16:42:18 I1X Average and RMS of Measurements VT = -87.577 +- 3.868 uVs I1X = 17.515 +- 0.774 uTm 16:42:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:42:24 Integrated Voltage Measurement... 16:42:33 Voltage Offset Correction: v_off_ini = 380.736 uV, v_off_fin = 377.363 uV 16:42:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.212 uVs 16:42:33 Integrated Voltage Measurement... 16:42:42 Voltage Offset Correction: v_off_ini = 377.607 uV, v_off_fin = 382.075 uV 16:42:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.168 uVs 16:42:42 Integrated Voltage Measurement... 16:42:51 Voltage Offset Correction: v_off_ini = 384.106 uV, v_off_fin = 379.492 uV 16:42:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.371 uVs 16:42:51 Integrated Voltage Measurement... 16:43:00 Voltage Offset Correction: v_off_ini = 377.898 uV, v_off_fin = 401.292 uV 16:43:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.900 uVs 16:43:00 Integrated Voltage Measurement... 16:43:09 Voltage Offset Correction: v_off_ini = 370.227 uV, v_off_fin = 370.429 uV 16:43:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.602 uVs 16:43:09 Integrated Voltage Measurement... 16:43:18 Voltage Offset Correction: v_off_ini = 382.621 uV, v_off_fin = 397.995 uV 16:43:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.055 uVs 16:43:23 I1Y Average and RMS of Measurements VT = -189.551 +- 9.152 uVs I1Y = -37.910 +- 1.830 uTm 16:43:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:43:28 Integrated Voltage Measurement... 16:43:37 Voltage Offset Correction: v_off_ini = 391.008 uV, v_off_fin = 382.584 uV 16:43:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.157 uVs 16:43:37 Integrated Voltage Measurement... 16:43:46 Voltage Offset Correction: v_off_ini = 380.760 uV, v_off_fin = 398.204 uV 16:43:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.489 uVs 16:43:46 Integrated Voltage Measurement... 16:43:55 Voltage Offset Correction: v_off_ini = 377.471 uV, v_off_fin = 372.903 uV 16:43:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.870 uVs 16:43:55 Integrated Voltage Measurement... 16:44:04 Voltage Offset Correction: v_off_ini = 378.302 uV, v_off_fin = 380.197 uV 16:44:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.950 uVs 16:44:04 Integrated Voltage Measurement... 16:44:13 Voltage Offset Correction: v_off_ini = 379.721 uV, v_off_fin = 353.982 uV 16:44:13 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -86.398 uVs 16:44:13 Integrated Voltage Measurement... 16:44:22 Voltage Offset Correction: v_off_ini = 380.068 uV, v_off_fin = 389.202 uV 16:44:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.864 uVs 16:44:24 I2X Average and RMS of Measurements VT = -73.788 +- 6.226 uVs I2X = 6.789 +- 0.573 uTm^2 16:44:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:44:29 Integrated Voltage Measurement... 16:44:38 Voltage Offset Correction: v_off_ini = 377.091 uV, v_off_fin = 374.133 uV 16:44:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.119 uVs 16:44:38 Integrated Voltage Measurement... 16:44:47 Voltage Offset Correction: v_off_ini = 371.348 uV, v_off_fin = 377.643 uV 16:44:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.925 uVs 16:44:48 Integrated Voltage Measurement... 16:44:56 Voltage Offset Correction: v_off_ini = 376.323 uV, v_off_fin = 365.210 uV 16:44:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.605 uVs 16:44:57 Integrated Voltage Measurement... 16:45:06 Voltage Offset Correction: v_off_ini = 366.887 uV, v_off_fin = 355.733 uV 16:45:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.112 uVs 16:45:06 Integrated Voltage Measurement... 16:45:15 Voltage Offset Correction: v_off_ini = 376.267 uV, v_off_fin = 365.992 uV 16:45:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.245 uVs 16:45:15 Integrated Voltage Measurement... 16:45:24 Voltage Offset Correction: v_off_ini = 366.588 uV, v_off_fin = 368.138 uV 16:45:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.439 uVs 16:45:26 I2Y Average and RMS of Measurements VT = -355.741 +- 6.532 uVs I2Y = -32.728 +- 0.601 uTm^2 16:45:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:34 Integrated Voltage Measurement... 16:45:43 Voltage Offset Correction: v_off_ini = 366.452 uV, v_off_fin = 358.105 uV 16:45:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.435 uVs 16:45:43 Integrated Voltage Measurement... 16:45:52 Voltage Offset Correction: v_off_ini = 375.586 uV, v_off_fin = 374.743 uV 16:45:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.998 uVs 16:45:52 Integrated Voltage Measurement... 16:46:01 Voltage Offset Correction: v_off_ini = 364.912 uV, v_off_fin = 356.126 uV 16:46:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.309 uVs 16:46:01 Integrated Voltage Measurement... 16:46:10 Voltage Offset Correction: v_off_ini = 354.973 uV, v_off_fin = 364.270 uV 16:46:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.295 uVs 16:46:10 Integrated Voltage Measurement... 16:46:19 Voltage Offset Correction: v_off_ini = 376.482 uV, v_off_fin = 359.146 uV 16:46:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.135 uVs 16:46:19 Integrated Voltage Measurement... 16:46:28 Voltage Offset Correction: v_off_ini = 350.550 uV, v_off_fin = 358.214 uV 16:46:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.450 uVs 16:46:33 I1X Average and RMS of Measurements VT = -92.437 +- 16.766 uVs I1X = 18.488 +- 3.353 uTm 16:46:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:39 Integrated Voltage Measurement... 16:46:48 Voltage Offset Correction: v_off_ini = 361.805 uV, v_off_fin = 346.376 uV 16:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.765 uVs 16:46:48 Integrated Voltage Measurement... 16:46:57 Voltage Offset Correction: v_off_ini = 352.518 uV, v_off_fin = 366.444 uV 16:46:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.003 uVs 16:46:57 Integrated Voltage Measurement... 16:47:06 Voltage Offset Correction: v_off_ini = 361.544 uV, v_off_fin = 357.714 uV 16:47:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.762 uVs 16:47:06 Integrated Voltage Measurement... 16:47:15 Voltage Offset Correction: v_off_ini = 363.269 uV, v_off_fin = 379.438 uV 16:47:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.062 uVs 16:47:15 Integrated Voltage Measurement... 16:47:24 Voltage Offset Correction: v_off_ini = 360.101 uV, v_off_fin = 342.441 uV 16:47:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.345 uVs 16:47:24 Integrated Voltage Measurement... 16:47:33 Voltage Offset Correction: v_off_ini = 357.844 uV, v_off_fin = 361.202 uV 16:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.365 uVs 16:47:38 I1Y Average and RMS of Measurements VT = -190.883 +- 2.503 uVs I1Y = -38.177 +- 0.501 uTm 16:47:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:43 Integrated Voltage Measurement... 16:47:52 Voltage Offset Correction: v_off_ini = 356.586 uV, v_off_fin = 354.053 uV 16:47:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.507 uVs 16:47:52 Integrated Voltage Measurement... 16:48:01 Voltage Offset Correction: v_off_ini = 356.705 uV, v_off_fin = 381.448 uV 16:48:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.721 uVs 16:48:01 Integrated Voltage Measurement... 16:48:10 Voltage Offset Correction: v_off_ini = 358.838 uV, v_off_fin = 346.369 uV 16:48:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.233 uVs 16:48:10 Integrated Voltage Measurement... 16:48:19 Voltage Offset Correction: v_off_ini = 355.039 uV, v_off_fin = 358.217 uV 16:48:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.266 uVs 16:48:19 Integrated Voltage Measurement... 16:48:28 Voltage Offset Correction: v_off_ini = 351.973 uV, v_off_fin = 346.058 uV 16:48:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.059 uVs 16:48:28 Integrated Voltage Measurement... 16:48:37 Voltage Offset Correction: v_off_ini = 340.689 uV, v_off_fin = 351.920 uV 16:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.181 uVs 16:48:39 I2X Average and RMS of Measurements VT = -87.828 +- 4.604 uVs I2X = 8.080 +- 0.424 uTm^2 16:48:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:44 Integrated Voltage Measurement... 16:48:53 Voltage Offset Correction: v_off_ini = 358.641 uV, v_off_fin = 344.601 uV 16:48:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.300 uVs 16:48:53 Integrated Voltage Measurement... 16:49:02 Voltage Offset Correction: v_off_ini = 345.586 uV, v_off_fin = 353.353 uV 16:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.227 uVs 16:49:03 Integrated Voltage Measurement... 16:49:11 Voltage Offset Correction: v_off_ini = 348.001 uV, v_off_fin = 354.693 uV 16:49:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -376.883 uVs 16:49:12 Integrated Voltage Measurement... 16:49:21 Voltage Offset Correction: v_off_ini = 342.046 uV, v_off_fin = 347.132 uV 16:49:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.086 uVs 16:49:21 Integrated Voltage Measurement... 16:49:30 Voltage Offset Correction: v_off_ini = 336.353 uV, v_off_fin = 338.346 uV 16:49:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -357.927 uVs 16:49:30 Integrated Voltage Measurement... 16:49:39 Voltage Offset Correction: v_off_ini = 336.705 uV, v_off_fin = 343.528 uV 16:49:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.167 uVs 16:49:41 I2Y Average and RMS of Measurements VT = -356.932 +- 3.696 uVs I2Y = -32.839 +- 0.340 uTm^2 16:49:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:49:49 Integrated Voltage Measurement... 16:49:58 Voltage Offset Correction: v_off_ini = 324.363 uV, v_off_fin = 326.971 uV 16:49:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -104.192 uVs 16:49:58 Integrated Voltage Measurement... 16:50:07 Voltage Offset Correction: v_off_ini = 330.901 uV, v_off_fin = 324.990 uV 16:50:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.345 uVs 16:50:07 Integrated Voltage Measurement... 16:50:16 Voltage Offset Correction: v_off_ini = 340.612 uV, v_off_fin = 333.577 uV 16:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.335 uVs 16:50:16 Integrated Voltage Measurement... 16:50:25 Voltage Offset Correction: v_off_ini = 342.594 uV, v_off_fin = 345.389 uV 16:50:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.841 uVs 16:50:25 Integrated Voltage Measurement... 16:50:34 Voltage Offset Correction: v_off_ini = 336.495 uV, v_off_fin = 322.997 uV 16:50:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.467 uVs 16:50:34 Integrated Voltage Measurement... 16:50:43 Voltage Offset Correction: v_off_ini = 340.561 uV, v_off_fin = 338.040 uV 16:50:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 112.138 uVs 16:50:48 I1X Average and RMS of Measurements VT = -95.386 +- 3.663 uVs I1X = 19.080 +- 0.733 uTm 16:50:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:50:54 Integrated Voltage Measurement... 16:51:03 Voltage Offset Correction: v_off_ini = 363.473 uV, v_off_fin = 340.745 uV 16:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.278 uVs 16:51:03 Integrated Voltage Measurement... 16:51:12 Voltage Offset Correction: v_off_ini = 340.082 uV, v_off_fin = 344.449 uV 16:51:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.401 uVs 16:51:12 Integrated Voltage Measurement... 16:51:21 Voltage Offset Correction: v_off_ini = 338.477 uV, v_off_fin = 316.911 uV 16:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.887 uVs 16:51:21 Integrated Voltage Measurement... 16:51:30 Voltage Offset Correction: v_off_ini = 335.472 uV, v_off_fin = 338.404 uV 16:51:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.846 uVs 16:51:30 Integrated Voltage Measurement... 16:51:39 Voltage Offset Correction: v_off_ini = 340.871 uV, v_off_fin = 322.560 uV 16:51:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.678 uVs 16:51:39 Integrated Voltage Measurement... 16:51:48 Voltage Offset Correction: v_off_ini = 326.944 uV, v_off_fin = 343.690 uV 16:51:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.001 uVs 16:51:53 I1Y Average and RMS of Measurements VT = -189.515 +- 3.285 uVs I1Y = -37.902 +- 0.659 uTm 16:51:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:51:58 Integrated Voltage Measurement... 16:52:07 Voltage Offset Correction: v_off_ini = 326.385 uV, v_off_fin = 322.209 uV 16:52:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.583 uVs 16:52:07 Integrated Voltage Measurement... 16:52:16 Voltage Offset Correction: v_off_ini = 319.852 uV, v_off_fin = 320.175 uV 16:52:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.041 uVs 16:52:16 Integrated Voltage Measurement... 16:52:25 Voltage Offset Correction: v_off_ini = 324.406 uV, v_off_fin = 305.068 uV 16:52:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.441 uVs 16:52:25 Integrated Voltage Measurement... 16:52:34 Voltage Offset Correction: v_off_ini = 333.483 uV, v_off_fin = 338.453 uV 16:52:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.229 uVs 16:52:34 Integrated Voltage Measurement... 16:52:43 Voltage Offset Correction: v_off_ini = 319.646 uV, v_off_fin = 318.385 uV 16:52:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.985 uVs 16:52:43 Integrated Voltage Measurement... 16:52:52 Voltage Offset Correction: v_off_ini = 325.085 uV, v_off_fin = 324.652 uV 16:52:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.553 uVs 16:52:54 I2X Average and RMS of Measurements VT = -88.306 +- 9.415 uVs I2X = 8.124 +- 0.866 uTm^2 16:52:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:52:59 Integrated Voltage Measurement... 16:53:08 Voltage Offset Correction: v_off_ini = 316.093 uV, v_off_fin = 320.356 uV 16:53:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.271 uVs 16:53:09 Integrated Voltage Measurement... 16:53:17 Voltage Offset Correction: v_off_ini = 307.966 uV, v_off_fin = 314.404 uV 16:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.061 uVs 16:53:18 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = 302.275 uV, v_off_fin = 309.008 uV 16:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.876 uVs 16:53:27 Integrated Voltage Measurement... 16:53:36 Voltage Offset Correction: v_off_ini = 305.154 uV, v_off_fin = 306.946 uV 16:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.440 uVs 16:53:36 Integrated Voltage Measurement... 16:53:45 Voltage Offset Correction: v_off_ini = 310.598 uV, v_off_fin = 298.130 uV 16:53:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.150 uVs 16:53:45 Integrated Voltage Measurement... 16:53:54 Voltage Offset Correction: v_off_ini = 305.640 uV, v_off_fin = 297.259 uV 16:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.973 uVs 16:53:56 I2Y Average and RMS of Measurements VT = -362.462 +- 3.840 uVs I2Y = -33.346 +- 0.353 uTm^2 16:54:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:54:04 Integrated Voltage Measurement... 16:54:13 Voltage Offset Correction: v_off_ini = 316.906 uV, v_off_fin = 316.109 uV 16:54:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.439 uVs 16:54:13 Integrated Voltage Measurement... 16:54:22 Voltage Offset Correction: v_off_ini = 302.080 uV, v_off_fin = 303.469 uV 16:54:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.509 uVs 16:54:22 Integrated Voltage Measurement... 16:54:31 Voltage Offset Correction: v_off_ini = 314.761 uV, v_off_fin = 297.814 uV 16:54:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.725 uVs 16:54:31 Integrated Voltage Measurement... 16:54:40 Voltage Offset Correction: v_off_ini = 323.913 uV, v_off_fin = 325.344 uV 16:54:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.387 uVs 16:54:40 Integrated Voltage Measurement... 16:54:49 Voltage Offset Correction: v_off_ini = 309.319 uV, v_off_fin = 310.108 uV 16:54:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.627 uVs 16:54:50 Integrated Voltage Measurement... 16:54:58 Voltage Offset Correction: v_off_ini = 314.301 uV, v_off_fin = 311.464 uV 16:54:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.196 uVs 16:55:03 I1X Average and RMS of Measurements VT = -92.647 +- 5.575 uVs I1X = 18.530 +- 1.115 uTm 16:55:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:55:09 Integrated Voltage Measurement... 16:55:18 Voltage Offset Correction: v_off_ini = 315.636 uV, v_off_fin = 317.990 uV 16:55:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.677 uVs 16:55:18 Integrated Voltage Measurement... 16:55:27 Voltage Offset Correction: v_off_ini = 319.700 uV, v_off_fin = 333.760 uV 16:55:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.279 uVs 16:55:27 Integrated Voltage Measurement... 16:55:36 Voltage Offset Correction: v_off_ini = 332.440 uV, v_off_fin = 314.814 uV 16:55:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.232 uVs 16:55:36 Integrated Voltage Measurement... 16:55:45 Voltage Offset Correction: v_off_ini = 324.756 uV, v_off_fin = 330.355 uV 16:55:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.331 uVs 16:55:45 Integrated Voltage Measurement... 16:55:54 Voltage Offset Correction: v_off_ini = 303.217 uV, v_off_fin = 305.866 uV 16:55:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.431 uVs 16:55:54 Integrated Voltage Measurement... 16:56:03 Voltage Offset Correction: v_off_ini = 314.002 uV, v_off_fin = 312.103 uV 16:56:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.605 uVs 16:56:08 I1Y Average and RMS of Measurements VT = -190.092 +- 4.068 uVs I1Y = -38.016 +- 0.814 uTm 16:56:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:56:13 Integrated Voltage Measurement... 16:56:22 Voltage Offset Correction: v_off_ini = 311.950 uV, v_off_fin = 312.055 uV 16:56:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.659 uVs 16:56:22 Integrated Voltage Measurement... 16:56:31 Voltage Offset Correction: v_off_ini = 318.262 uV, v_off_fin = 322.749 uV 16:56:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.376 uVs 16:56:31 Integrated Voltage Measurement... 16:56:40 Voltage Offset Correction: v_off_ini = 304.408 uV, v_off_fin = 309.469 uV 16:56:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.008 uVs 16:56:40 Integrated Voltage Measurement... 16:56:49 Voltage Offset Correction: v_off_ini = 313.596 uV, v_off_fin = 317.439 uV 16:56:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.634 uVs 16:56:49 Integrated Voltage Measurement... 16:56:58 Voltage Offset Correction: v_off_ini = 318.773 uV, v_off_fin = 314.208 uV 16:56:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.767 uVs 16:56:58 Integrated Voltage Measurement... 16:57:07 Voltage Offset Correction: v_off_ini = 315.596 uV, v_off_fin = 295.095 uV 16:57:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.040 uVs 16:57:09 I2X Average and RMS of Measurements VT = -97.414 +- 1.016 uVs I2X = 8.962 +- 0.093 uTm^2 16:57:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:57:14 Integrated Voltage Measurement... 16:57:23 Voltage Offset Correction: v_off_ini = 308.440 uV, v_off_fin = 310.487 uV 16:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.718 uVs 16:57:23 Integrated Voltage Measurement... 16:57:32 Voltage Offset Correction: v_off_ini = 309.348 uV, v_off_fin = 304.696 uV 16:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.296 uVs 16:57:33 Integrated Voltage Measurement... 16:57:41 Voltage Offset Correction: v_off_ini = 308.154 uV, v_off_fin = 312.293 uV 16:57:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.465 uVs 16:57:42 Integrated Voltage Measurement... 16:57:51 Voltage Offset Correction: v_off_ini = 309.093 uV, v_off_fin = 318.894 uV 16:57:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.404 uVs 16:57:51 Integrated Voltage Measurement... 16:58:00 Voltage Offset Correction: v_off_ini = 325.527 uV, v_off_fin = 305.541 uV 16:58:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.912 uVs 16:58:00 Integrated Voltage Measurement... 16:58:09 Voltage Offset Correction: v_off_ini = 317.415 uV, v_off_fin = 310.442 uV 16:58:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.302 uVs 16:58:11 I2Y Average and RMS of Measurements VT = -370.350 +- 4.056 uVs I2Y = -34.072 +- 0.373 uTm^2 16:58:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:58:32 Integrated Voltage Measurement... 16:58:41 Voltage Offset Correction: v_off_ini = 311.385 uV, v_off_fin = 307.324 uV 16:58:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -122.182 uVs 16:58:41 Integrated Voltage Measurement... 16:58:50 Voltage Offset Correction: v_off_ini = 296.467 uV, v_off_fin = 311.950 uV 16:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.843 uVs 16:58:50 Integrated Voltage Measurement... 16:58:59 Voltage Offset Correction: v_off_ini = 304.876 uV, v_off_fin = 311.784 uV 16:58:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.997 uVs 16:58:59 Integrated Voltage Measurement... 16:59:08 Voltage Offset Correction: v_off_ini = 312.088 uV, v_off_fin = 311.972 uV 16:59:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.054 uVs 16:59:08 Integrated Voltage Measurement... 16:59:17 Voltage Offset Correction: v_off_ini = 307.100 uV, v_off_fin = 301.639 uV 16:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.509 uVs 16:59:17 Integrated Voltage Measurement... 16:59:26 Voltage Offset Correction: v_off_ini = 308.999 uV, v_off_fin = 310.463 uV 16:59:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.929 uVs 16:59:31 I1X Average and RMS of Measurements VT = -104.919 +- 11.531 uVs I1X = 20.985 +- 2.307 uTm 16:59:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:59:37 Integrated Voltage Measurement... 16:59:46 Voltage Offset Correction: v_off_ini = 308.987 uV, v_off_fin = 302.268 uV 16:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.491 uVs 16:59:46 Integrated Voltage Measurement... 16:59:55 Voltage Offset Correction: v_off_ini = 297.403 uV, v_off_fin = 295.906 uV 16:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.965 uVs 16:59:55 Integrated Voltage Measurement... 17:00:04 Voltage Offset Correction: v_off_ini = 311.134 uV, v_off_fin = 302.198 uV 17:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.798 uVs 17:00:04 Integrated Voltage Measurement... 17:00:13 Voltage Offset Correction: v_off_ini = 314.429 uV, v_off_fin = 328.547 uV 17:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.084 uVs 17:00:13 Integrated Voltage Measurement... 17:00:22 Voltage Offset Correction: v_off_ini = 317.921 uV, v_off_fin = 307.202 uV 17:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.949 uVs 17:00:22 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = 315.291 uV, v_off_fin = 310.940 uV 17:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.988 uVs 17:00:36 I1Y Average and RMS of Measurements VT = -201.379 +- 6.531 uVs I1Y = -40.276 +- 1.306 uTm 17:00:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:00:43 Integrated Voltage Measurement... 17:00:52 Voltage Offset Correction: v_off_ini = 288.605 uV, v_off_fin = 301.305 uV 17:00:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.518 uVs 17:00:52 Integrated Voltage Measurement... 17:01:01 Voltage Offset Correction: v_off_ini = 308.799 uV, v_off_fin = 314.103 uV 17:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.269 uVs 17:01:01 Integrated Voltage Measurement... 17:01:10 Voltage Offset Correction: v_off_ini = 303.097 uV, v_off_fin = 282.185 uV 17:01:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.097 uVs 17:01:10 Integrated Voltage Measurement... 17:01:19 Voltage Offset Correction: v_off_ini = 282.205 uV, v_off_fin = 291.483 uV 17:01:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.789 uVs 17:01:19 Integrated Voltage Measurement... 17:01:28 Voltage Offset Correction: v_off_ini = 281.150 uV, v_off_fin = 280.731 uV 17:01:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.099 uVs 17:01:29 Integrated Voltage Measurement... 17:01:37 Voltage Offset Correction: v_off_ini = 294.036 uV, v_off_fin = 292.864 uV 17:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.491 uVs 17:01:40 I2X Average and RMS of Measurements VT = -95.210 +- 6.176 uVs I2X = 8.759 +- 0.568 uTm^2 17:01:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:01:48 Integrated Voltage Measurement... 17:01:57 Voltage Offset Correction: v_off_ini = 288.185 uV, v_off_fin = 298.265 uV 17:01:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.576 uVs 17:01:57 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = 284.883 uV, v_off_fin = 297.121 uV 17:02:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 334.259 uVs 17:02:06 Integrated Voltage Measurement... 17:02:15 Voltage Offset Correction: v_off_ini = 298.694 uV, v_off_fin = 297.219 uV 17:02:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.357 uVs 17:02:15 Integrated Voltage Measurement... 17:02:24 Voltage Offset Correction: v_off_ini = 279.166 uV, v_off_fin = 290.078 uV 17:02:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.642 uVs 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = 294.418 uV, v_off_fin = 292.438 uV 17:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.198 uVs 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = 284.044 uV, v_off_fin = 284.765 uV 17:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.950 uVs 17:02:44 I2Y Average and RMS of Measurements VT = -353.664 +- 7.304 uVs I2Y = -32.538 +- 0.671 uTm^2 17:02:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:02:53 Integrated Voltage Measurement... 17:03:02 Voltage Offset Correction: v_off_ini = 291.448 uV, v_off_fin = 272.864 uV 17:03:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -107.965 uVs 17:03:02 Integrated Voltage Measurement... 17:03:11 Voltage Offset Correction: v_off_ini = 276.421 uV, v_off_fin = 278.184 uV 17:03:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.224 uVs 17:03:11 Integrated Voltage Measurement... 17:03:20 Voltage Offset Correction: v_off_ini = 279.833 uV, v_off_fin = 290.648 uV 17:03:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.105 uVs 17:03:20 Integrated Voltage Measurement... 17:03:29 Voltage Offset Correction: v_off_ini = 300.015 uV, v_off_fin = 289.539 uV 17:03:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.851 uVs 17:03:29 Integrated Voltage Measurement... 17:03:38 Voltage Offset Correction: v_off_ini = 275.299 uV, v_off_fin = 293.203 uV 17:03:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.152 uVs 17:03:38 Integrated Voltage Measurement... 17:03:47 Voltage Offset Correction: v_off_ini = 286.029 uV, v_off_fin = 293.510 uV 17:03:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.368 uVs 17:03:51 I1X Average and RMS of Measurements VT = -100.111 +- 5.068 uVs I1X = 20.024 +- 1.013 uTm 17:03:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:03:58 Integrated Voltage Measurement... 17:04:07 Voltage Offset Correction: v_off_ini = 279.315 uV, v_off_fin = 282.914 uV 17:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.678 uVs 17:04:07 Integrated Voltage Measurement... 17:04:16 Voltage Offset Correction: v_off_ini = 283.209 uV, v_off_fin = 288.624 uV 17:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.881 uVs 17:04:16 Integrated Voltage Measurement... 17:04:25 Voltage Offset Correction: v_off_ini = 278.911 uV, v_off_fin = 273.171 uV 17:04:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.692 uVs 17:04:25 Integrated Voltage Measurement... 17:04:34 Voltage Offset Correction: v_off_ini = 286.655 uV, v_off_fin = 300.530 uV 17:04:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.689 uVs 17:04:34 Integrated Voltage Measurement... 17:04:43 Voltage Offset Correction: v_off_ini = 290.318 uV, v_off_fin = 285.364 uV 17:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.446 uVs 17:04:43 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 294.276 uV, v_off_fin = 296.554 uV 17:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.104 uVs 17:04:56 I1Y Average and RMS of Measurements VT = -191.582 +- 6.607 uVs I1Y = -38.316 +- 1.321 uTm 17:05:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:05:04 Integrated Voltage Measurement... 17:05:13 Voltage Offset Correction: v_off_ini = 283.999 uV, v_off_fin = 284.063 uV 17:05:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -108.956 uVs 17:05:13 Integrated Voltage Measurement... 17:05:22 Voltage Offset Correction: v_off_ini = 296.004 uV, v_off_fin = 289.176 uV 17:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.758 uVs 17:05:22 Integrated Voltage Measurement... 17:05:31 Voltage Offset Correction: v_off_ini = 292.838 uV, v_off_fin = 282.146 uV 17:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.866 uVs 17:05:31 Integrated Voltage Measurement... 17:05:40 Voltage Offset Correction: v_off_ini = 287.715 uV, v_off_fin = 302.361 uV 17:05:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.304 uVs 17:05:40 Integrated Voltage Measurement... 17:05:49 Voltage Offset Correction: v_off_ini = 298.991 uV, v_off_fin = 296.041 uV 17:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.323 uVs 17:05:49 Integrated Voltage Measurement... 17:05:58 Voltage Offset Correction: v_off_ini = 300.492 uV, v_off_fin = 316.771 uV 17:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.735 uVs 17:06:01 I2X Average and RMS of Measurements VT = -103.157 +- 9.638 uVs I2X = 9.490 +- 0.887 uTm^2 17:06:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:06:08 Integrated Voltage Measurement... 17:06:17 Voltage Offset Correction: v_off_ini = 301.634 uV, v_off_fin = 292.564 uV 17:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.783 uVs 17:06:17 Integrated Voltage Measurement... 17:06:26 Voltage Offset Correction: v_off_ini = 294.499 uV, v_off_fin = 301.766 uV 17:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.289 uVs 17:06:26 Integrated Voltage Measurement... 17:06:35 Voltage Offset Correction: v_off_ini = 300.155 uV, v_off_fin = 306.078 uV 17:06:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.926 uVs 17:06:35 Integrated Voltage Measurement... 17:06:44 Voltage Offset Correction: v_off_ini = 296.753 uV, v_off_fin = 295.184 uV 17:06:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.210 uVs 17:06:44 Integrated Voltage Measurement... 17:06:53 Voltage Offset Correction: v_off_ini = 290.002 uV, v_off_fin = 298.406 uV 17:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.887 uVs 17:06:54 Integrated Voltage Measurement... 17:07:02 Voltage Offset Correction: v_off_ini = 305.924 uV, v_off_fin = 305.616 uV 17:07:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.678 uVs 17:07:05 I2Y Average and RMS of Measurements VT = -329.462 +- 2.089 uVs I2Y = -30.311 +- 0.192 uTm^2 17:07:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:07:14 Integrated Voltage Measurement... 17:07:23 Voltage Offset Correction: v_off_ini = 297.404 uV, v_off_fin = 289.819 uV 17:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.542 uVs 17:07:23 Integrated Voltage Measurement... 17:07:32 Voltage Offset Correction: v_off_ini = 300.890 uV, v_off_fin = 304.766 uV 17:07:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.147 uVs 17:07:32 Integrated Voltage Measurement... 17:07:41 Voltage Offset Correction: v_off_ini = 285.706 uV, v_off_fin = 292.511 uV 17:07:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.030 uVs 17:07:41 Integrated Voltage Measurement... 17:07:50 Voltage Offset Correction: v_off_ini = 289.640 uV, v_off_fin = 283.656 uV 17:07:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.769 uVs 17:07:50 Integrated Voltage Measurement... 17:07:59 Voltage Offset Correction: v_off_ini = 286.516 uV, v_off_fin = 286.072 uV 17:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.938 uVs 17:07:59 Integrated Voltage Measurement... 17:08:08 Voltage Offset Correction: v_off_ini = 306.411 uV, v_off_fin = 290.041 uV 17:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.737 uVs 17:08:12 I1X Average and RMS of Measurements VT = -99.527 +- 8.304 uVs I1X = 19.906 +- 1.661 uTm 17:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:19 Integrated Voltage Measurement... 17:08:28 Voltage Offset Correction: v_off_ini = 280.680 uV, v_off_fin = 280.096 uV 17:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.844 uVs 17:08:28 Integrated Voltage Measurement... 17:08:37 Voltage Offset Correction: v_off_ini = 294.161 uV, v_off_fin = 296.273 uV 17:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.249 uVs 17:08:37 Integrated Voltage Measurement... 17:08:46 Voltage Offset Correction: v_off_ini = 281.401 uV, v_off_fin = 286.012 uV 17:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.917 uVs 17:08:46 Integrated Voltage Measurement... 17:08:55 Voltage Offset Correction: v_off_ini = 293.603 uV, v_off_fin = 299.442 uV 17:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.648 uVs 17:08:55 Integrated Voltage Measurement... 17:09:04 Voltage Offset Correction: v_off_ini = 295.421 uV, v_off_fin = 268.702 uV 17:09:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.624 uVs 17:09:04 Integrated Voltage Measurement... 17:09:13 Voltage Offset Correction: v_off_ini = 284.582 uV, v_off_fin = 297.797 uV 17:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.904 uVs 17:09:17 I1Y Average and RMS of Measurements VT = -172.864 +- 4.784 uVs I1Y = -34.573 +- 0.957 uTm 17:09:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:25 Integrated Voltage Measurement... 17:09:34 Voltage Offset Correction: v_off_ini = 268.086 uV, v_off_fin = 265.677 uV 17:09:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.140 uVs 17:09:34 Integrated Voltage Measurement... 17:09:43 Voltage Offset Correction: v_off_ini = 285.964 uV, v_off_fin = 289.091 uV 17:09:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.468 uVs 17:09:43 Integrated Voltage Measurement... 17:09:52 Voltage Offset Correction: v_off_ini = 281.805 uV, v_off_fin = 273.696 uV 17:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.385 uVs 17:09:52 Integrated Voltage Measurement... 17:10:01 Voltage Offset Correction: v_off_ini = 281.590 uV, v_off_fin = 288.096 uV 17:10:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.753 uVs 17:10:01 Integrated Voltage Measurement... 17:10:10 Voltage Offset Correction: v_off_ini = 275.050 uV, v_off_fin = 277.149 uV 17:10:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.813 uVs 17:10:10 Integrated Voltage Measurement... 17:10:19 Voltage Offset Correction: v_off_ini = 278.850 uV, v_off_fin = 283.608 uV 17:10:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.957 uVs 17:10:21 I2X Average and RMS of Measurements VT = -100.253 +- 2.699 uVs I2X = 9.223 +- 0.248 uTm^2 17:10:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:29 Integrated Voltage Measurement... 17:10:38 Voltage Offset Correction: v_off_ini = 280.581 uV, v_off_fin = 266.847 uV 17:10:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.116 uVs 17:10:38 Integrated Voltage Measurement... 17:10:47 Voltage Offset Correction: v_off_ini = 285.931 uV, v_off_fin = 275.609 uV 17:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.437 uVs 17:10:47 Integrated Voltage Measurement... 17:10:56 Voltage Offset Correction: v_off_ini = 269.405 uV, v_off_fin = 282.239 uV 17:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.083 uVs 17:10:56 Integrated Voltage Measurement... 17:11:05 Voltage Offset Correction: v_off_ini = 265.144 uV, v_off_fin = 270.191 uV 17:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.797 uVs 17:11:05 Integrated Voltage Measurement... 17:11:14 Voltage Offset Correction: v_off_ini = 264.926 uV, v_off_fin = 263.772 uV 17:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.721 uVs 17:11:14 Integrated Voltage Measurement... 17:11:23 Voltage Offset Correction: v_off_ini = 259.155 uV, v_off_fin = 263.864 uV 17:11:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.420 uVs 17:11:26 I2Y Average and RMS of Measurements VT = -322.762 +- 7.429 uVs I2Y = -29.694 +- 0.683 uTm^2 17:11:30 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:11:34 Integrated Voltage Measurement... 17:11:43 Voltage Offset Correction: v_off_ini = 267.665 uV, v_off_fin = 259.117 uV 17:11:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -122.789 uVs 17:11:44 Integrated Voltage Measurement... 17:11:52 Voltage Offset Correction: v_off_ini = 268.793 uV, v_off_fin = 273.682 uV 17:11:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.994 uVs 17:11:53 Integrated Voltage Measurement... 17:12:01 Voltage Offset Correction: v_off_ini = 260.047 uV, v_off_fin = 269.838 uV 17:12:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.639 uVs 17:12:02 Integrated Voltage Measurement... 17:12:10 Voltage Offset Correction: v_off_ini = 272.053 uV, v_off_fin = 269.321 uV 17:12:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 110.700 uVs 17:12:11 Integrated Voltage Measurement... 17:12:19 Voltage Offset Correction: v_off_ini = 268.264 uV, v_off_fin = 277.327 uV 17:12:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.741 uVs 17:12:20 Integrated Voltage Measurement... 17:12:28 Voltage Offset Correction: v_off_ini = 277.540 uV, v_off_fin = 278.510 uV 17:12:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.415 uVs 17:12:33 I1X Average and RMS of Measurements VT = -108.880 +- 14.426 uVs I1X = 21.778 +- 2.887 uTm 17:12:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:12:39 Integrated Voltage Measurement... 17:12:48 Voltage Offset Correction: v_off_ini = 255.186 uV, v_off_fin = 261.263 uV 17:12:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.662 uVs 17:12:48 Integrated Voltage Measurement... 17:12:57 Voltage Offset Correction: v_off_ini = 264.424 uV, v_off_fin = 267.800 uV 17:12:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.102 uVs 17:12:57 Integrated Voltage Measurement... 17:13:06 Voltage Offset Correction: v_off_ini = 274.916 uV, v_off_fin = 269.329 uV 17:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.223 uVs 17:13:06 Integrated Voltage Measurement... 17:13:15 Voltage Offset Correction: v_off_ini = 266.951 uV, v_off_fin = 282.285 uV 17:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.018 uVs 17:13:15 Integrated Voltage Measurement... 17:13:24 Voltage Offset Correction: v_off_ini = 266.851 uV, v_off_fin = 269.608 uV 17:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.470 uVs 17:13:24 Integrated Voltage Measurement... 17:13:33 Voltage Offset Correction: v_off_ini = 266.672 uV, v_off_fin = 275.554 uV 17:13:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.230 uVs 17:13:38 I1Y Average and RMS of Measurements VT = -158.617 +- 5.407 uVs I1Y = -31.723 +- 1.081 uTm 17:13:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:13:45 Integrated Voltage Measurement... 17:13:54 Voltage Offset Correction: v_off_ini = 264.266 uV, v_off_fin = 271.168 uV 17:13:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.511 uVs 17:13:54 Integrated Voltage Measurement... 17:14:03 Voltage Offset Correction: v_off_ini = 282.941 uV, v_off_fin = 283.376 uV 17:14:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.933 uVs 17:14:03 Integrated Voltage Measurement... 17:14:12 Voltage Offset Correction: v_off_ini = 283.063 uV, v_off_fin = 259.887 uV 17:14:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.651 uVs 17:14:12 Integrated Voltage Measurement... 17:14:21 Voltage Offset Correction: v_off_ini = 272.192 uV, v_off_fin = 277.675 uV 17:14:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.413 uVs 17:14:21 Integrated Voltage Measurement... 17:14:30 Voltage Offset Correction: v_off_ini = 275.775 uV, v_off_fin = 273.388 uV 17:14:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.397 uVs 17:14:30 Integrated Voltage Measurement... 17:14:39 Voltage Offset Correction: v_off_ini = 292.061 uV, v_off_fin = 297.541 uV 17:14:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.341 uVs 17:14:42 I2X Average and RMS of Measurements VT = -114.374 +- 3.539 uVs I2X = 10.522 +- 0.326 uTm^2 17:14:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:14:50 Integrated Voltage Measurement... 17:14:58 Voltage Offset Correction: v_off_ini = 280.608 uV, v_off_fin = 299.095 uV 17:14:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.640 uVs 17:14:59 Integrated Voltage Measurement... 17:15:08 Voltage Offset Correction: v_off_ini = 286.684 uV, v_off_fin = 277.010 uV 17:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.632 uVs 17:15:08 Integrated Voltage Measurement... 17:15:17 Voltage Offset Correction: v_off_ini = 284.988 uV, v_off_fin = 279.385 uV 17:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.176 uVs 17:15:17 Integrated Voltage Measurement... 17:15:26 Voltage Offset Correction: v_off_ini = 273.416 uV, v_off_fin = 283.323 uV 17:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.052 uVs 17:15:26 Integrated Voltage Measurement... 17:15:35 Voltage Offset Correction: v_off_ini = 260.826 uV, v_off_fin = 261.504 uV 17:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.415 uVs 17:15:35 Integrated Voltage Measurement... 17:15:44 Voltage Offset Correction: v_off_ini = 276.432 uV, v_off_fin = 276.369 uV 17:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.661 uVs 17:15:46 I2Y Average and RMS of Measurements VT = -298.596 +- 8.191 uVs I2Y = -27.471 +- 0.754 uTm^2 17:15:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:15:55 Integrated Voltage Measurement... 17:16:04 Voltage Offset Correction: v_off_ini = 271.072 uV, v_off_fin = 263.435 uV 17:16:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.741 uVs 17:16:04 Integrated Voltage Measurement... 17:16:13 Voltage Offset Correction: v_off_ini = 257.690 uV, v_off_fin = 266.404 uV 17:16:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.309 uVs 17:16:13 Integrated Voltage Measurement... 17:16:22 Voltage Offset Correction: v_off_ini = 260.345 uV, v_off_fin = 264.472 uV 17:16:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.595 uVs 17:16:22 Integrated Voltage Measurement... 17:16:31 Voltage Offset Correction: v_off_ini = 264.722 uV, v_off_fin = 266.977 uV 17:16:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 124.037 uVs 17:16:31 Integrated Voltage Measurement... 17:16:40 Voltage Offset Correction: v_off_ini = 261.943 uV, v_off_fin = 261.358 uV 17:16:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.175 uVs 17:16:40 Integrated Voltage Measurement... 17:16:49 Voltage Offset Correction: v_off_ini = 257.368 uV, v_off_fin = 257.527 uV 17:16:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.475 uVs 17:16:53 I1X Average and RMS of Measurements VT = -120.555 +- 7.942 uVs I1X = 24.113 +- 1.589 uTm 17:16:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:17:00 Integrated Voltage Measurement... 17:17:09 Voltage Offset Correction: v_off_ini = 267.411 uV, v_off_fin = 257.827 uV 17:17:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.236 uVs 17:17:09 Integrated Voltage Measurement... 17:17:18 Voltage Offset Correction: v_off_ini = 253.807 uV, v_off_fin = 268.082 uV 17:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.905 uVs 17:17:18 Integrated Voltage Measurement... 17:17:27 Voltage Offset Correction: v_off_ini = 258.550 uV, v_off_fin = 246.109 uV 17:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.654 uVs 17:17:27 Integrated Voltage Measurement... 17:17:36 Voltage Offset Correction: v_off_ini = 262.127 uV, v_off_fin = 276.055 uV 17:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.137 uVs 17:17:36 Integrated Voltage Measurement... 17:17:45 Voltage Offset Correction: v_off_ini = 266.735 uV, v_off_fin = 251.768 uV 17:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.980 uVs 17:17:45 Integrated Voltage Measurement... 17:17:54 Voltage Offset Correction: v_off_ini = 263.560 uV, v_off_fin = 273.916 uV 17:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 120.618 uVs 17:17:58 I1Y Average and RMS of Measurements VT = -136.255 +- 5.503 uVs I1Y = -27.251 +- 1.101 uTm 17:18:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:18:06 Integrated Voltage Measurement... 17:18:15 Voltage Offset Correction: v_off_ini = 227.719 uV, v_off_fin = 233.231 uV 17:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.062 uVs 17:18:15 Integrated Voltage Measurement... 17:18:24 Voltage Offset Correction: v_off_ini = 236.688 uV, v_off_fin = 256.768 uV 17:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.088 uVs 17:18:24 Integrated Voltage Measurement... 17:18:33 Voltage Offset Correction: v_off_ini = 231.313 uV, v_off_fin = 220.016 uV 17:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.688 uVs 17:18:33 Integrated Voltage Measurement... 17:18:42 Voltage Offset Correction: v_off_ini = 233.243 uV, v_off_fin = 230.972 uV 17:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.061 uVs 17:18:42 Integrated Voltage Measurement... 17:18:51 Voltage Offset Correction: v_off_ini = 227.928 uV, v_off_fin = 198.830 uV 17:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.393 uVs 17:18:51 Integrated Voltage Measurement... 17:19:00 Voltage Offset Correction: v_off_ini = 214.429 uV, v_off_fin = 230.959 uV 17:19:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.480 uVs 17:19:02 I2X Average and RMS of Measurements VT = -122.129 +- 1.289 uVs I2X = 11.236 +- 0.119 uTm^2 17:19:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:19:10 Integrated Voltage Measurement... 17:19:19 Voltage Offset Correction: v_off_ini = 236.535 uV, v_off_fin = 232.689 uV 17:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.868 uVs 17:19:19 Integrated Voltage Measurement... 17:19:28 Voltage Offset Correction: v_off_ini = 222.654 uV, v_off_fin = 223.863 uV 17:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.521 uVs 17:19:28 Integrated Voltage Measurement... 17:19:37 Voltage Offset Correction: v_off_ini = 224.104 uV, v_off_fin = 214.759 uV 17:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.352 uVs 17:19:37 Integrated Voltage Measurement... 17:19:46 Voltage Offset Correction: v_off_ini = 217.291 uV, v_off_fin = 226.845 uV 17:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.460 uVs 17:19:46 Integrated Voltage Measurement... 17:19:55 Voltage Offset Correction: v_off_ini = 232.046 uV, v_off_fin = 229.474 uV 17:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.967 uVs 17:19:55 Integrated Voltage Measurement... 17:20:04 Voltage Offset Correction: v_off_ini = 219.855 uV, v_off_fin = 216.115 uV 17:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.261 uVs 17:20:07 I2Y Average and RMS of Measurements VT = -281.572 +- 2.790 uVs I2Y = -25.905 +- 0.257 uTm^2 17:20:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:20:18 Integrated Voltage Measurement... 17:20:27 Voltage Offset Correction: v_off_ini = 220.118 uV, v_off_fin = 225.964 uV 17:20:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -93.514 uVs 17:20:28 Integrated Voltage Measurement... 17:20:36 Voltage Offset Correction: v_off_ini = 227.018 uV, v_off_fin = 231.115 uV 17:20:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.424 uVs 17:20:37 Integrated Voltage Measurement... 17:20:45 Voltage Offset Correction: v_off_ini = 227.718 uV, v_off_fin = 230.568 uV 17:20:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.950 uVs 17:20:46 Integrated Voltage Measurement... 17:20:54 Voltage Offset Correction: v_off_ini = 246.059 uV, v_off_fin = 228.733 uV 17:20:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.310 uVs 17:20:55 Integrated Voltage Measurement... 17:21:03 Voltage Offset Correction: v_off_ini = 231.946 uV, v_off_fin = 238.718 uV 17:21:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.906 uVs 17:21:04 Integrated Voltage Measurement... 17:21:12 Voltage Offset Correction: v_off_ini = 235.961 uV, v_off_fin = 240.225 uV 17:21:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 72.704 uVs 17:21:17 I1X Average and RMS of Measurements VT = -75.635 +- 4.059 uVs I1X = 15.128 +- 0.813 uTm 17:21:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:21:23 Integrated Voltage Measurement... 17:21:32 Voltage Offset Correction: v_off_ini = 228.045 uV, v_off_fin = 218.933 uV 17:21:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.042 uVs 17:21:32 Integrated Voltage Measurement... 17:21:41 Voltage Offset Correction: v_off_ini = 223.818 uV, v_off_fin = 233.385 uV 17:21:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.756 uVs 17:21:41 Integrated Voltage Measurement... 17:21:50 Voltage Offset Correction: v_off_ini = 226.518 uV, v_off_fin = 216.301 uV 17:21:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.344 uVs 17:21:50 Integrated Voltage Measurement... 17:21:59 Voltage Offset Correction: v_off_ini = 240.485 uV, v_off_fin = 240.080 uV 17:21:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.161 uVs 17:21:59 Integrated Voltage Measurement... 17:22:08 Voltage Offset Correction: v_off_ini = 228.863 uV, v_off_fin = 224.071 uV 17:22:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.032 uVs 17:22:08 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = 223.288 uV, v_off_fin = 243.187 uV 17:22:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.909 uVs 17:22:22 I1Y Average and RMS of Measurements VT = -170.874 +- 1.868 uVs I1Y = -34.175 +- 0.374 uTm 17:22:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:22:27 Integrated Voltage Measurement... 17:22:36 Voltage Offset Correction: v_off_ini = 217.634 uV, v_off_fin = 224.289 uV 17:22:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.720 uVs 17:22:36 Integrated Voltage Measurement... 17:22:45 Voltage Offset Correction: v_off_ini = 240.847 uV, v_off_fin = 245.562 uV 17:22:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.727 uVs 17:22:45 Integrated Voltage Measurement... 17:22:54 Voltage Offset Correction: v_off_ini = 232.508 uV, v_off_fin = 228.151 uV 17:22:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.747 uVs 17:22:54 Integrated Voltage Measurement... 17:23:03 Voltage Offset Correction: v_off_ini = 249.355 uV, v_off_fin = 246.910 uV 17:23:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.611 uVs 17:23:03 Integrated Voltage Measurement... 17:23:12 Voltage Offset Correction: v_off_ini = 236.706 uV, v_off_fin = 229.529 uV 17:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.512 uVs 17:23:12 Integrated Voltage Measurement... 17:23:21 Voltage Offset Correction: v_off_ini = 241.153 uV, v_off_fin = 242.313 uV 17:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.165 uVs 17:23:23 I2X Average and RMS of Measurements VT = -73.747 +- 8.278 uVs I2X = 6.785 +- 0.762 uTm^2 17:23:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:23:28 Integrated Voltage Measurement... 17:23:37 Voltage Offset Correction: v_off_ini = 250.337 uV, v_off_fin = 237.041 uV 17:23:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.913 uVs 17:23:37 Integrated Voltage Measurement... 17:23:46 Voltage Offset Correction: v_off_ini = 239.147 uV, v_off_fin = 231.181 uV 17:23:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.005 uVs 17:23:46 Integrated Voltage Measurement... 17:23:55 Voltage Offset Correction: v_off_ini = 246.142 uV, v_off_fin = 257.623 uV 17:23:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.907 uVs 17:23:55 Integrated Voltage Measurement... 17:24:04 Voltage Offset Correction: v_off_ini = 257.159 uV, v_off_fin = 267.428 uV 17:24:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.866 uVs 17:24:04 Integrated Voltage Measurement... 17:24:13 Voltage Offset Correction: v_off_ini = 263.497 uV, v_off_fin = 254.561 uV 17:24:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.771 uVs 17:24:13 Integrated Voltage Measurement... 17:24:22 Voltage Offset Correction: v_off_ini = 254.995 uV, v_off_fin = 255.952 uV 17:24:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.946 uVs 17:24:25 I2Y Average and RMS of Measurements VT = -315.902 +- 5.939 uVs I2Y = -29.063 +- 0.546 uTm^2 17:24:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:24:33 Integrated Voltage Measurement... 17:24:42 Voltage Offset Correction: v_off_ini = 253.499 uV, v_off_fin = 257.571 uV 17:24:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.599 uVs 17:24:42 Integrated Voltage Measurement... 17:24:51 Voltage Offset Correction: v_off_ini = 250.455 uV, v_off_fin = 252.763 uV 17:24:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.792 uVs 17:24:51 Integrated Voltage Measurement... 17:25:00 Voltage Offset Correction: v_off_ini = 254.440 uV, v_off_fin = 254.215 uV 17:25:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.389 uVs 17:25:00 Integrated Voltage Measurement... 17:25:09 Voltage Offset Correction: v_off_ini = 251.524 uV, v_off_fin = 256.811 uV 17:25:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.776 uVs 17:25:09 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = 253.642 uV, v_off_fin = 255.992 uV 17:25:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.819 uVs 17:25:18 Integrated Voltage Measurement... 17:25:27 Voltage Offset Correction: v_off_ini = 267.338 uV, v_off_fin = 249.489 uV 17:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.611 uVs 17:25:31 I1X Average and RMS of Measurements VT = -95.331 +- 6.807 uVs I1X = 19.067 +- 1.362 uTm 17:25:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:25:38 Integrated Voltage Measurement... 17:25:47 Voltage Offset Correction: v_off_ini = 256.418 uV, v_off_fin = 256.802 uV 17:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.086 uVs 17:25:47 Integrated Voltage Measurement... 17:25:56 Voltage Offset Correction: v_off_ini = 255.753 uV, v_off_fin = 271.063 uV 17:25:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.241 uVs 17:25:56 Integrated Voltage Measurement... 17:26:05 Voltage Offset Correction: v_off_ini = 257.406 uV, v_off_fin = 257.344 uV 17:26:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.422 uVs 17:26:05 Integrated Voltage Measurement... 17:26:14 Voltage Offset Correction: v_off_ini = 255.449 uV, v_off_fin = 275.489 uV 17:26:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.147 uVs 17:26:14 Integrated Voltage Measurement... 17:26:23 Voltage Offset Correction: v_off_ini = 269.277 uV, v_off_fin = 242.617 uV 17:26:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.648 uVs 17:26:23 Integrated Voltage Measurement... 17:26:32 Voltage Offset Correction: v_off_ini = 271.214 uV, v_off_fin = 283.415 uV 17:26:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.186 uVs 17:26:36 I1Y Average and RMS of Measurements VT = -168.455 +- 8.042 uVs I1Y = -33.691 +- 1.608 uTm 17:26:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:26:41 Integrated Voltage Measurement... 17:26:50 Voltage Offset Correction: v_off_ini = 256.869 uV, v_off_fin = 261.991 uV 17:26:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.350 uVs 17:26:50 Integrated Voltage Measurement... 17:26:59 Voltage Offset Correction: v_off_ini = 264.553 uV, v_off_fin = 282.584 uV 17:26:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.572 uVs 17:26:59 Integrated Voltage Measurement... 17:27:08 Voltage Offset Correction: v_off_ini = 270.676 uV, v_off_fin = 256.274 uV 17:27:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.640 uVs 17:27:08 Integrated Voltage Measurement... 17:27:17 Voltage Offset Correction: v_off_ini = 276.411 uV, v_off_fin = 284.620 uV 17:27:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.053 uVs 17:27:17 Integrated Voltage Measurement... 17:27:26 Voltage Offset Correction: v_off_ini = 274.616 uV, v_off_fin = 278.774 uV 17:27:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.619 uVs 17:27:26 Integrated Voltage Measurement... 17:27:35 Voltage Offset Correction: v_off_ini = 272.553 uV, v_off_fin = 282.307 uV 17:27:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.802 uVs 17:27:38 I2X Average and RMS of Measurements VT = -91.006 +- 0.723 uVs I2X = 8.372 +- 0.066 uTm^2 17:27:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = 275.252 uV, v_off_fin = 278.515 uV 17:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.579 uVs 17:27:52 Integrated Voltage Measurement... 17:28:01 Voltage Offset Correction: v_off_ini = 282.786 uV, v_off_fin = 298.964 uV 17:28:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.313 uVs 17:28:01 Integrated Voltage Measurement... 17:28:10 Voltage Offset Correction: v_off_ini = 286.011 uV, v_off_fin = 280.539 uV 17:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.119 uVs 17:28:10 Integrated Voltage Measurement... 17:28:19 Voltage Offset Correction: v_off_ini = 278.062 uV, v_off_fin = 283.329 uV 17:28:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.905 uVs 17:28:19 Integrated Voltage Measurement... 17:28:28 Voltage Offset Correction: v_off_ini = 275.568 uV, v_off_fin = 280.995 uV 17:28:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.459 uVs 17:28:28 Integrated Voltage Measurement... 17:28:37 Voltage Offset Correction: v_off_ini = 277.218 uV, v_off_fin = 278.819 uV 17:28:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.843 uVs 17:28:40 I2Y Average and RMS of Measurements VT = -315.370 +- 3.032 uVs I2Y = -29.014 +- 0.279 uTm^2 17:28:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:28:48 Integrated Voltage Measurement... 17:28:57 Voltage Offset Correction: v_off_ini = 272.222 uV, v_off_fin = 275.404 uV 17:28:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -133.211 uVs 17:28:57 Integrated Voltage Measurement... 17:29:06 Voltage Offset Correction: v_off_ini = 282.138 uV, v_off_fin = 276.825 uV 17:29:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.454 uVs 17:29:06 Integrated Voltage Measurement... 17:29:15 Voltage Offset Correction: v_off_ini = 280.248 uV, v_off_fin = 280.746 uV 17:29:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.780 uVs 17:29:15 Integrated Voltage Measurement... 17:29:24 Voltage Offset Correction: v_off_ini = 272.256 uV, v_off_fin = 284.441 uV 17:29:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.071 uVs 17:29:24 Integrated Voltage Measurement... 17:29:33 Voltage Offset Correction: v_off_ini = 275.691 uV, v_off_fin = 265.353 uV 17:29:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.662 uVs 17:29:33 Integrated Voltage Measurement... 17:29:42 Voltage Offset Correction: v_off_ini = 284.237 uV, v_off_fin = 292.026 uV 17:29:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.378 uVs 17:29:46 I1X Average and RMS of Measurements VT = -110.093 +- 8.884 uVs I1X = 22.020 +- 1.778 uTm 17:29:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:29:53 Integrated Voltage Measurement... 17:30:02 Voltage Offset Correction: v_off_ini = 269.568 uV, v_off_fin = 265.718 uV 17:30:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.440 uVs 17:30:02 Integrated Voltage Measurement... 17:30:11 Voltage Offset Correction: v_off_ini = 263.215 uV, v_off_fin = 279.483 uV 17:30:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.058 uVs 17:30:11 Integrated Voltage Measurement... 17:30:20 Voltage Offset Correction: v_off_ini = 272.771 uV, v_off_fin = 254.033 uV 17:30:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.271 uVs 17:30:20 Integrated Voltage Measurement... 17:30:29 Voltage Offset Correction: v_off_ini = 282.568 uV, v_off_fin = 291.233 uV 17:30:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.374 uVs 17:30:29 Integrated Voltage Measurement... 17:30:38 Voltage Offset Correction: v_off_ini = 268.837 uV, v_off_fin = 257.024 uV 17:30:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.904 uVs 17:30:38 Integrated Voltage Measurement... 17:30:47 Voltage Offset Correction: v_off_ini = 257.229 uV, v_off_fin = 272.750 uV 17:30:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.460 uVs 17:30:51 I1Y Average and RMS of Measurements VT = -174.751 +- 5.576 uVs I1Y = -34.951 +- 1.116 uTm 17:30:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:30:56 Integrated Voltage Measurement... 17:31:05 Voltage Offset Correction: v_off_ini = 253.739 uV, v_off_fin = 253.944 uV 17:31:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.481 uVs 17:31:05 Integrated Voltage Measurement... 17:31:14 Voltage Offset Correction: v_off_ini = 269.022 uV, v_off_fin = 273.264 uV 17:31:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.493 uVs 17:31:14 Integrated Voltage Measurement... 17:31:23 Voltage Offset Correction: v_off_ini = 265.832 uV, v_off_fin = 263.626 uV 17:31:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.722 uVs 17:31:23 Integrated Voltage Measurement... 17:31:32 Voltage Offset Correction: v_off_ini = 250.886 uV, v_off_fin = 273.036 uV 17:31:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.030 uVs 17:31:32 Integrated Voltage Measurement... 17:31:41 Voltage Offset Correction: v_off_ini = 266.151 uV, v_off_fin = 246.325 uV 17:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.810 uVs 17:31:41 Integrated Voltage Measurement... 17:31:50 Voltage Offset Correction: v_off_ini = 254.063 uV, v_off_fin = 263.103 uV 17:31:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.454 uVs 17:31:53 I2X Average and RMS of Measurements VT = -103.165 +- 5.867 uVs I2X = 9.491 +- 0.540 uTm^2 17:31:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:31:58 Integrated Voltage Measurement... 17:32:07 Voltage Offset Correction: v_off_ini = 238.638 uV, v_off_fin = 254.703 uV 17:32:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.072 uVs 17:32:07 Integrated Voltage Measurement... 17:32:16 Voltage Offset Correction: v_off_ini = 253.332 uV, v_off_fin = 260.585 uV 17:32:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.518 uVs 17:32:16 Integrated Voltage Measurement... 17:32:25 Voltage Offset Correction: v_off_ini = 262.586 uV, v_off_fin = 256.521 uV 17:32:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.442 uVs 17:32:25 Integrated Voltage Measurement... 17:32:34 Voltage Offset Correction: v_off_ini = 257.876 uV, v_off_fin = 252.130 uV 17:32:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.491 uVs 17:32:34 Integrated Voltage Measurement... 17:32:43 Voltage Offset Correction: v_off_ini = 245.851 uV, v_off_fin = 239.936 uV 17:32:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.552 uVs 17:32:43 Integrated Voltage Measurement... 17:32:52 Voltage Offset Correction: v_off_ini = 242.152 uV, v_off_fin = 244.332 uV 17:32:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.600 uVs 17:32:54 I2Y Average and RMS of Measurements VT = -315.613 +- 7.748 uVs I2Y = -29.036 +- 0.713 uTm^2 17:32:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:33:03 Integrated Voltage Measurement... 17:33:12 Voltage Offset Correction: v_off_ini = 259.405 uV, v_off_fin = 242.571 uV 17:33:12 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4999 mm dXY = -0.4998 mm VT = -116.877 uVs 17:33:12 Integrated Voltage Measurement... 17:33:21 Voltage Offset Correction: v_off_ini = 247.826 uV, v_off_fin = 242.957 uV 17:33:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.302 uVs 17:33:21 Integrated Voltage Measurement... 17:33:30 Voltage Offset Correction: v_off_ini = 248.917 uV, v_off_fin = 248.178 uV 17:33:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.032 uVs 17:33:30 Integrated Voltage Measurement... 17:33:39 Voltage Offset Correction: v_off_ini = 258.723 uV, v_off_fin = 257.800 uV 17:33:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.508 uVs 17:33:39 Integrated Voltage Measurement... 17:33:48 Voltage Offset Correction: v_off_ini = 246.533 uV, v_off_fin = 247.144 uV 17:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.523 uVs 17:33:48 Integrated Voltage Measurement... 17:33:57 Voltage Offset Correction: v_off_ini = 240.412 uV, v_off_fin = 252.257 uV 17:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.497 uVs 17:34:01 I1X Average and RMS of Measurements VT = -108.790 +- 4.243 uVs I1X = 21.760 +- 0.850 uTm 17:34:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:34:08 Integrated Voltage Measurement... 17:34:17 Voltage Offset Correction: v_off_ini = 229.420 uV, v_off_fin = 227.040 uV 17:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -165.346 uVs 17:34:17 Integrated Voltage Measurement... 17:34:26 Voltage Offset Correction: v_off_ini = 219.364 uV, v_off_fin = 227.125 uV 17:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.264 uVs 17:34:26 Integrated Voltage Measurement... 17:34:35 Voltage Offset Correction: v_off_ini = 236.671 uV, v_off_fin = 227.841 uV 17:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.584 uVs 17:34:35 Integrated Voltage Measurement... 17:34:44 Voltage Offset Correction: v_off_ini = 234.040 uV, v_off_fin = 247.245 uV 17:34:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.839 uVs 17:34:44 Integrated Voltage Measurement... 17:34:53 Voltage Offset Correction: v_off_ini = 248.222 uV, v_off_fin = 233.940 uV 17:34:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.144 uVs 17:34:53 Integrated Voltage Measurement... 17:35:02 Voltage Offset Correction: v_off_ini = 242.175 uV, v_off_fin = 252.444 uV 17:35:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.230 uVs 17:35:06 I1Y Average and RMS of Measurements VT = -171.568 +- 2.341 uVs I1Y = -34.315 +- 0.468 uTm 17:35:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:35:11 Integrated Voltage Measurement... 17:35:20 Voltage Offset Correction: v_off_ini = 246.511 uV, v_off_fin = 232.052 uV 17:35:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -99.583 uVs 17:35:20 Integrated Voltage Measurement... 17:35:29 Voltage Offset Correction: v_off_ini = 252.950 uV, v_off_fin = 249.732 uV 17:35:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.936 uVs 17:35:29 Integrated Voltage Measurement... 17:35:38 Voltage Offset Correction: v_off_ini = 244.541 uV, v_off_fin = 245.975 uV 17:35:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.860 uVs 17:35:38 Integrated Voltage Measurement... 17:35:47 Voltage Offset Correction: v_off_ini = 255.505 uV, v_off_fin = 266.555 uV 17:35:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.787 uVs 17:35:47 Integrated Voltage Measurement... 17:35:56 Voltage Offset Correction: v_off_ini = 258.844 uV, v_off_fin = 237.772 uV 17:35:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.421 uVs 17:35:56 Integrated Voltage Measurement... 17:36:05 Voltage Offset Correction: v_off_ini = 254.134 uV, v_off_fin = 239.937 uV 17:36:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.404 uVs 17:36:08 I2X Average and RMS of Measurements VT = -102.332 +- 5.444 uVs I2X = 9.415 +- 0.500 uTm^2 17:36:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:36:13 Integrated Voltage Measurement... 17:36:22 Voltage Offset Correction: v_off_ini = 250.601 uV, v_off_fin = 240.607 uV 17:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.772 uVs 17:36:22 Integrated Voltage Measurement... 17:36:31 Voltage Offset Correction: v_off_ini = 246.932 uV, v_off_fin = 230.358 uV 17:36:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.746 uVs 17:36:31 Integrated Voltage Measurement... 17:36:40 Voltage Offset Correction: v_off_ini = 243.066 uV, v_off_fin = 232.733 uV 17:36:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.113 uVs 17:36:40 Integrated Voltage Measurement... 17:36:49 Voltage Offset Correction: v_off_ini = 237.104 uV, v_off_fin = 253.165 uV 17:36:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.509 uVs 17:36:49 Integrated Voltage Measurement... 17:36:58 Voltage Offset Correction: v_off_ini = 258.285 uV, v_off_fin = 250.169 uV 17:36:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.642 uVs 17:36:58 Integrated Voltage Measurement... 17:37:07 Voltage Offset Correction: v_off_ini = 249.568 uV, v_off_fin = 251.010 uV 17:37:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.595 uVs 17:37:09 I2Y Average and RMS of Measurements VT = -322.230 +- 1.358 uVs I2Y = -29.645 +- 0.125 uTm^2 17:37:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:37:18 Integrated Voltage Measurement... 17:37:27 Voltage Offset Correction: v_off_ini = 247.074 uV, v_off_fin = 239.376 uV 17:37:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.519 uVs 17:37:27 Integrated Voltage Measurement... 17:37:36 Voltage Offset Correction: v_off_ini = 244.588 uV, v_off_fin = 248.700 uV 17:37:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.239 uVs 17:37:36 Integrated Voltage Measurement... 17:37:45 Voltage Offset Correction: v_off_ini = 245.082 uV, v_off_fin = 240.678 uV 17:37:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.025 uVs 17:37:45 Integrated Voltage Measurement... 17:37:54 Voltage Offset Correction: v_off_ini = 225.250 uV, v_off_fin = 231.920 uV 17:37:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.024 uVs 17:37:54 Integrated Voltage Measurement... 17:38:03 Voltage Offset Correction: v_off_ini = 232.710 uV, v_off_fin = 235.618 uV 17:38:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.991 uVs 17:38:03 Integrated Voltage Measurement... 17:38:12 Voltage Offset Correction: v_off_ini = 234.586 uV, v_off_fin = 238.015 uV 17:38:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.413 uVs 17:38:16 I1X Average and RMS of Measurements VT = -112.202 +- 6.676 uVs I1X = 22.441 +- 1.334 uTm 17:38:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:38:23 Integrated Voltage Measurement... 17:38:32 Voltage Offset Correction: v_off_ini = 231.533 uV, v_off_fin = 228.002 uV 17:38:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -165.600 uVs 17:38:32 Integrated Voltage Measurement... 17:38:41 Voltage Offset Correction: v_off_ini = 243.983 uV, v_off_fin = 245.574 uV 17:38:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.478 uVs 17:38:41 Integrated Voltage Measurement... 17:38:50 Voltage Offset Correction: v_off_ini = 240.690 uV, v_off_fin = 220.899 uV 17:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.700 uVs 17:38:50 Integrated Voltage Measurement... 17:38:59 Voltage Offset Correction: v_off_ini = 238.772 uV, v_off_fin = 239.232 uV 17:38:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.336 uVs 17:38:59 Integrated Voltage Measurement... 17:39:08 Voltage Offset Correction: v_off_ini = 237.062 uV, v_off_fin = 214.013 uV 17:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.837 uVs 17:39:08 Integrated Voltage Measurement... 17:39:17 Voltage Offset Correction: v_off_ini = 230.230 uV, v_off_fin = 236.088 uV 17:39:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.636 uVs 17:39:21 I1Y Average and RMS of Measurements VT = -173.764 +- 6.065 uVs I1Y = -34.752 +- 1.210 uTm 17:39:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:39:26 Integrated Voltage Measurement... 17:39:35 Voltage Offset Correction: v_off_ini = 228.166 uV, v_off_fin = 215.333 uV 17:39:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.755 uVs 17:39:35 Integrated Voltage Measurement... 17:39:44 Voltage Offset Correction: v_off_ini = 230.821 uV, v_off_fin = 230.802 uV 17:39:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.044 uVs 17:39:44 Integrated Voltage Measurement... 17:39:53 Voltage Offset Correction: v_off_ini = 205.850 uV, v_off_fin = 217.717 uV 17:39:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.841 uVs 17:39:53 Integrated Voltage Measurement... 17:40:02 Voltage Offset Correction: v_off_ini = 212.154 uV, v_off_fin = 222.409 uV 17:40:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.623 uVs 17:40:02 Integrated Voltage Measurement... 17:40:11 Voltage Offset Correction: v_off_ini = 211.403 uV, v_off_fin = 213.205 uV 17:40:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.533 uVs 17:40:11 Integrated Voltage Measurement... 17:40:20 Voltage Offset Correction: v_off_ini = 222.026 uV, v_off_fin = 225.906 uV 17:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.041 uVs 17:40:23 I2X Average and RMS of Measurements VT = -112.640 +- 4.553 uVs I2X = 10.363 +- 0.419 uTm^2 17:40:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:40:28 Integrated Voltage Measurement... 17:40:37 Voltage Offset Correction: v_off_ini = 220.996 uV, v_off_fin = 222.936 uV 17:40:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.606 uVs 17:40:37 Integrated Voltage Measurement... 17:40:46 Voltage Offset Correction: v_off_ini = 220.201 uV, v_off_fin = 223.880 uV 17:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.881 uVs 17:40:46 Integrated Voltage Measurement... 17:40:55 Voltage Offset Correction: v_off_ini = 225.342 uV, v_off_fin = 218.913 uV 17:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.636 uVs 17:40:55 Integrated Voltage Measurement... 17:41:04 Voltage Offset Correction: v_off_ini = 211.328 uV, v_off_fin = 216.774 uV 17:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.179 uVs 17:41:04 Integrated Voltage Measurement... 17:41:13 Voltage Offset Correction: v_off_ini = 224.193 uV, v_off_fin = 220.921 uV 17:41:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.912 uVs 17:41:13 Integrated Voltage Measurement... 17:41:22 Voltage Offset Correction: v_off_ini = 215.987 uV, v_off_fin = 226.357 uV 17:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.422 uVs 17:41:24 I2Y Average and RMS of Measurements VT = -327.439 +- 3.190 uVs I2Y = -30.124 +- 0.293 uTm^2 17:41:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:41:46 Integrated Voltage Measurement... 17:41:55 Voltage Offset Correction: v_off_ini = 223.681 uV, v_off_fin = 224.248 uV 17:41:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -110.024 uVs 17:41:55 Integrated Voltage Measurement... 17:42:04 Voltage Offset Correction: v_off_ini = 232.269 uV, v_off_fin = 220.146 uV 17:42:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.456 uVs 17:42:04 Integrated Voltage Measurement... 17:42:13 Voltage Offset Correction: v_off_ini = 221.236 uV, v_off_fin = 209.172 uV 17:42:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.064 uVs 17:42:13 Integrated Voltage Measurement... 17:42:22 Voltage Offset Correction: v_off_ini = 215.383 uV, v_off_fin = 213.071 uV 17:42:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.447 uVs 17:42:22 Integrated Voltage Measurement... 17:42:31 Voltage Offset Correction: v_off_ini = 211.401 uV, v_off_fin = 223.867 uV 17:42:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.823 uVs 17:42:31 Integrated Voltage Measurement... 17:42:40 Voltage Offset Correction: v_off_ini = 248.312 uV, v_off_fin = 255.008 uV 17:42:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.282 uVs 17:42:44 I1X Average and RMS of Measurements VT = -107.683 +- 11.131 uVs I1X = 21.538 +- 2.226 uTm 17:42:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:42:51 Integrated Voltage Measurement... 17:43:00 Voltage Offset Correction: v_off_ini = 251.643 uV, v_off_fin = 216.713 uV 17:43:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -181.247 uVs 17:43:00 Integrated Voltage Measurement... 17:43:09 Voltage Offset Correction: v_off_ini = 227.658 uV, v_off_fin = 236.361 uV 17:43:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.427 uVs 17:43:09 Integrated Voltage Measurement... 17:43:18 Voltage Offset Correction: v_off_ini = 226.746 uV, v_off_fin = 223.961 uV 17:43:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.853 uVs 17:43:18 Integrated Voltage Measurement... 17:43:27 Voltage Offset Correction: v_off_ini = 233.868 uV, v_off_fin = 235.128 uV 17:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.945 uVs 17:43:27 Integrated Voltage Measurement... 17:43:36 Voltage Offset Correction: v_off_ini = 227.398 uV, v_off_fin = 216.182 uV 17:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.387 uVs 17:43:36 Integrated Voltage Measurement... 17:43:45 Voltage Offset Correction: v_off_ini = 236.239 uV, v_off_fin = 245.488 uV 17:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.405 uVs 17:43:49 I1Y Average and RMS of Measurements VT = -182.044 +- 4.035 uVs I1Y = -36.409 +- 0.806 uTm 17:43:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:43:57 Integrated Voltage Measurement... 17:44:06 Voltage Offset Correction: v_off_ini = 229.616 uV, v_off_fin = 221.708 uV 17:44:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.783 uVs 17:44:06 Integrated Voltage Measurement... 17:44:15 Voltage Offset Correction: v_off_ini = 230.948 uV, v_off_fin = 241.866 uV 17:44:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.063 uVs 17:44:15 Integrated Voltage Measurement... 17:44:24 Voltage Offset Correction: v_off_ini = 250.306 uV, v_off_fin = 239.038 uV 17:44:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.064 uVs 17:44:24 Integrated Voltage Measurement... 17:44:33 Voltage Offset Correction: v_off_ini = 233.581 uV, v_off_fin = 235.040 uV 17:44:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.676 uVs 17:44:33 Integrated Voltage Measurement... 17:44:42 Voltage Offset Correction: v_off_ini = 226.316 uV, v_off_fin = 217.130 uV 17:44:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.952 uVs 17:44:42 Integrated Voltage Measurement... 17:44:51 Voltage Offset Correction: v_off_ini = 240.919 uV, v_off_fin = 234.109 uV 17:44:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.022 uVs 17:44:53 I2X Average and RMS of Measurements VT = -104.760 +- 2.332 uVs I2X = 9.638 +- 0.215 uTm^2 17:44:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:45:01 Integrated Voltage Measurement... 17:45:10 Voltage Offset Correction: v_off_ini = 213.455 uV, v_off_fin = 217.970 uV 17:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.696 uVs 17:45:10 Integrated Voltage Measurement... 17:45:19 Voltage Offset Correction: v_off_ini = 217.534 uV, v_off_fin = 221.190 uV 17:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.102 uVs 17:45:19 Integrated Voltage Measurement... 17:45:28 Voltage Offset Correction: v_off_ini = 221.804 uV, v_off_fin = 230.069 uV 17:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.160 uVs 17:45:28 Integrated Voltage Measurement... 17:45:37 Voltage Offset Correction: v_off_ini = 224.156 uV, v_off_fin = 214.511 uV 17:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.777 uVs 17:45:37 Integrated Voltage Measurement... 17:45:46 Voltage Offset Correction: v_off_ini = 228.957 uV, v_off_fin = 223.312 uV 17:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.248 uVs 17:45:46 Integrated Voltage Measurement... 17:45:55 Voltage Offset Correction: v_off_ini = 226.821 uV, v_off_fin = 209.714 uV 17:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.556 uVs 17:45:58 I2Y Average and RMS of Measurements VT = -316.256 +- 4.849 uVs I2Y = -29.096 +- 0.446 uTm^2 17:46:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:46:06 Integrated Voltage Measurement... 17:46:15 Voltage Offset Correction: v_off_ini = 225.383 uV, v_off_fin = 211.767 uV 17:46:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -121.329 uVs 17:46:15 Integrated Voltage Measurement... 17:46:24 Voltage Offset Correction: v_off_ini = 209.721 uV, v_off_fin = 221.830 uV 17:46:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.976 uVs 17:46:24 Integrated Voltage Measurement... 17:46:33 Voltage Offset Correction: v_off_ini = 220.041 uV, v_off_fin = 210.947 uV 17:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.726 uVs 17:46:33 Integrated Voltage Measurement... 17:46:42 Voltage Offset Correction: v_off_ini = 228.741 uV, v_off_fin = 213.728 uV 17:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.772 uVs 17:46:43 Integrated Voltage Measurement... 17:46:51 Voltage Offset Correction: v_off_ini = 224.866 uV, v_off_fin = 215.375 uV 17:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.203 uVs 17:46:52 Integrated Voltage Measurement... 17:47:00 Voltage Offset Correction: v_off_ini = 218.465 uV, v_off_fin = 217.863 uV 17:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.945 uVs 17:47:05 I1X Average and RMS of Measurements VT = -122.158 +- 8.782 uVs I1X = 24.433 +- 1.756 uTm 17:47:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:47:11 Integrated Voltage Measurement... 17:47:20 Voltage Offset Correction: v_off_ini = 217.253 uV, v_off_fin = 202.532 uV 17:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.057 uVs 17:47:20 Integrated Voltage Measurement... 17:47:29 Voltage Offset Correction: v_off_ini = 221.795 uV, v_off_fin = 232.559 uV 17:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.746 uVs 17:47:30 Integrated Voltage Measurement... 17:47:38 Voltage Offset Correction: v_off_ini = 214.164 uV, v_off_fin = 216.694 uV 17:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.153 uVs 17:47:39 Integrated Voltage Measurement... 17:47:47 Voltage Offset Correction: v_off_ini = 231.890 uV, v_off_fin = 233.196 uV 17:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.994 uVs 17:47:48 Integrated Voltage Measurement... 17:47:56 Voltage Offset Correction: v_off_ini = 222.364 uV, v_off_fin = 214.979 uV 17:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.386 uVs 17:47:57 Integrated Voltage Measurement... 17:48:05 Voltage Offset Correction: v_off_ini = 216.871 uV, v_off_fin = 231.395 uV 17:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.042 uVs 17:48:10 I1Y Average and RMS of Measurements VT = -171.396 +- 2.592 uVs I1Y = -34.279 +- 0.518 uTm 17:48:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:48:17 Integrated Voltage Measurement... 17:48:26 Voltage Offset Correction: v_off_ini = 234.670 uV, v_off_fin = 219.386 uV 17:48:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.015 uVs 17:48:26 Integrated Voltage Measurement... 17:48:35 Voltage Offset Correction: v_off_ini = 238.909 uV, v_off_fin = 244.394 uV 17:48:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.873 uVs 17:48:35 Integrated Voltage Measurement... 17:48:44 Voltage Offset Correction: v_off_ini = 222.922 uV, v_off_fin = 216.504 uV 17:48:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.412 uVs 17:48:45 Integrated Voltage Measurement... 17:48:53 Voltage Offset Correction: v_off_ini = 232.382 uV, v_off_fin = 241.967 uV 17:48:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.200 uVs 17:48:54 Integrated Voltage Measurement... 17:49:03 Voltage Offset Correction: v_off_ini = 232.927 uV, v_off_fin = 227.360 uV 17:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.004 uVs 17:49:03 Integrated Voltage Measurement... 17:49:12 Voltage Offset Correction: v_off_ini = 240.373 uV, v_off_fin = 252.337 uV 17:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.814 uVs 17:49:14 I2X Average and RMS of Measurements VT = -115.886 +- 2.601 uVs I2X = 10.661 +- 0.239 uTm^2 17:49:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:49:22 Integrated Voltage Measurement... 17:49:31 Voltage Offset Correction: v_off_ini = 219.478 uV, v_off_fin = 219.643 uV 17:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.568 uVs 17:49:31 Integrated Voltage Measurement... 17:49:40 Voltage Offset Correction: v_off_ini = 221.810 uV, v_off_fin = 226.211 uV 17:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.486 uVs 17:49:40 Integrated Voltage Measurement... 17:49:49 Voltage Offset Correction: v_off_ini = 210.455 uV, v_off_fin = 215.188 uV 17:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.634 uVs 17:49:49 Integrated Voltage Measurement... 17:49:58 Voltage Offset Correction: v_off_ini = 219.561 uV, v_off_fin = 221.388 uV 17:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.926 uVs 17:49:58 Integrated Voltage Measurement... 17:50:07 Voltage Offset Correction: v_off_ini = 229.678 uV, v_off_fin = 235.045 uV 17:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.226 uVs 17:50:07 Integrated Voltage Measurement... 17:50:16 Voltage Offset Correction: v_off_ini = 217.193 uV, v_off_fin = 227.621 uV 17:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.677 uVs 17:50:18 I2Y Average and RMS of Measurements VT = -305.920 +- 8.884 uVs I2Y = -28.145 +- 0.817 uTm^2 17:50:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:50:27 Integrated Voltage Measurement... 17:50:36 Voltage Offset Correction: v_off_ini = 226.968 uV, v_off_fin = 230.325 uV 17:50:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.263 uVs 17:50:36 Integrated Voltage Measurement... 17:50:45 Voltage Offset Correction: v_off_ini = 225.523 uV, v_off_fin = 225.727 uV 17:50:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.995 uVs 17:50:45 Integrated Voltage Measurement... 17:50:54 Voltage Offset Correction: v_off_ini = 227.704 uV, v_off_fin = 208.626 uV 17:50:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.655 uVs 17:50:54 Integrated Voltage Measurement... 17:51:03 Voltage Offset Correction: v_off_ini = 215.655 uV, v_off_fin = 221.370 uV 17:51:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.233 uVs 17:51:03 Integrated Voltage Measurement... 17:51:12 Voltage Offset Correction: v_off_ini = 226.455 uV, v_off_fin = 216.601 uV 17:51:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.514 uVs 17:51:12 Integrated Voltage Measurement... 17:51:21 Voltage Offset Correction: v_off_ini = 201.544 uV, v_off_fin = 219.905 uV 17:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 121.221 uVs 17:51:25 I1X Average and RMS of Measurements VT = -117.480 +- 4.567 uVs I1X = 23.498 +- 0.912 uTm 17:51:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:51:32 Integrated Voltage Measurement... 17:51:41 Voltage Offset Correction: v_off_ini = 209.653 uV, v_off_fin = 208.722 uV 17:51:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.500 uVs 17:51:41 Integrated Voltage Measurement... 17:51:50 Voltage Offset Correction: v_off_ini = 201.184 uV, v_off_fin = 216.603 uV 17:51:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.325 uVs 17:51:50 Integrated Voltage Measurement... 17:51:59 Voltage Offset Correction: v_off_ini = 202.600 uV, v_off_fin = 203.644 uV 17:51:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.360 uVs 17:51:59 Integrated Voltage Measurement... 17:52:08 Voltage Offset Correction: v_off_ini = 206.000 uV, v_off_fin = 226.268 uV 17:52:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.644 uVs 17:52:08 Integrated Voltage Measurement... 17:52:17 Voltage Offset Correction: v_off_ini = 219.503 uV, v_off_fin = 204.390 uV 17:52:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.951 uVs 17:52:17 Integrated Voltage Measurement... 17:52:26 Voltage Offset Correction: v_off_ini = 205.833 uV, v_off_fin = 220.728 uV 17:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.600 uVs 17:52:30 I1Y Average and RMS of Measurements VT = -156.063 +- 3.795 uVs I1Y = -31.213 +- 0.759 uTm 17:52:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:52:38 Integrated Voltage Measurement... 17:52:47 Voltage Offset Correction: v_off_ini = 204.829 uV, v_off_fin = 201.647 uV 17:52:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.273 uVs 17:52:47 Integrated Voltage Measurement... 17:52:56 Voltage Offset Correction: v_off_ini = 207.990 uV, v_off_fin = 211.568 uV 17:52:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 122.948 uVs 17:52:56 Integrated Voltage Measurement... 17:53:05 Voltage Offset Correction: v_off_ini = 209.368 uV, v_off_fin = 202.258 uV 17:53:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.645 uVs 17:53:05 Integrated Voltage Measurement... 17:53:14 Voltage Offset Correction: v_off_ini = 205.803 uV, v_off_fin = 223.710 uV 17:53:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.104 uVs 17:53:14 Integrated Voltage Measurement... 17:53:23 Voltage Offset Correction: v_off_ini = 216.862 uV, v_off_fin = 211.906 uV 17:53:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.634 uVs 17:53:23 Integrated Voltage Measurement... 17:53:32 Voltage Offset Correction: v_off_ini = 212.890 uV, v_off_fin = 226.070 uV 17:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.936 uVs 17:53:35 I2X Average and RMS of Measurements VT = -118.257 +- 0.986 uVs I2X = 10.880 +- 0.091 uTm^2 17:53:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:53:42 Integrated Voltage Measurement... 17:53:51 Voltage Offset Correction: v_off_ini = 216.232 uV, v_off_fin = 227.625 uV 17:53:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.129 uVs 17:53:51 Integrated Voltage Measurement... 17:54:00 Voltage Offset Correction: v_off_ini = 215.222 uV, v_off_fin = 217.706 uV 17:54:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.076 uVs 17:54:00 Integrated Voltage Measurement... 17:54:09 Voltage Offset Correction: v_off_ini = 215.944 uV, v_off_fin = 224.969 uV 17:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.121 uVs 17:54:09 Integrated Voltage Measurement... 17:54:18 Voltage Offset Correction: v_off_ini = 238.252 uV, v_off_fin = 218.912 uV 17:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.713 uVs 17:54:18 Integrated Voltage Measurement... 17:54:27 Voltage Offset Correction: v_off_ini = 215.450 uV, v_off_fin = 213.845 uV 17:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.107 uVs 17:54:27 Integrated Voltage Measurement... 17:54:36 Voltage Offset Correction: v_off_ini = 217.083 uV, v_off_fin = 221.230 uV 17:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.928 uVs 17:54:39 I2Y Average and RMS of Measurements VT = -290.346 +- 8.962 uVs I2Y = -26.712 +- 0.824 uTm^2 17:54:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:54:48 Integrated Voltage Measurement... 17:54:57 Voltage Offset Correction: v_off_ini = 221.180 uV, v_off_fin = 213.563 uV 17:54:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.322 uVs 17:54:57 Integrated Voltage Measurement... 17:55:06 Voltage Offset Correction: v_off_ini = 214.057 uV, v_off_fin = 221.160 uV 17:55:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.685 uVs 17:55:06 Integrated Voltage Measurement... 17:55:15 Voltage Offset Correction: v_off_ini = 206.577 uV, v_off_fin = 213.501 uV 17:55:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.469 uVs 17:55:15 Integrated Voltage Measurement... 17:55:24 Voltage Offset Correction: v_off_ini = 223.423 uV, v_off_fin = 227.183 uV 17:55:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.572 uVs 17:55:24 Integrated Voltage Measurement... 17:55:33 Voltage Offset Correction: v_off_ini = 216.739 uV, v_off_fin = 212.579 uV 17:55:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.892 uVs 17:55:33 Integrated Voltage Measurement... 17:55:42 Voltage Offset Correction: v_off_ini = 205.481 uV, v_off_fin = 228.853 uV 17:55:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.018 uVs 17:55:46 I1X Average and RMS of Measurements VT = -125.326 +- 3.499 uVs I1X = 25.066 +- 0.700 uTm 17:55:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:55:53 Integrated Voltage Measurement... 17:56:02 Voltage Offset Correction: v_off_ini = 235.415 uV, v_off_fin = 220.475 uV 17:56:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.186 uVs 17:56:02 Integrated Voltage Measurement... 17:56:11 Voltage Offset Correction: v_off_ini = 229.559 uV, v_off_fin = 244.576 uV 17:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 138.849 uVs 17:56:11 Integrated Voltage Measurement... 17:56:20 Voltage Offset Correction: v_off_ini = 234.267 uV, v_off_fin = 222.219 uV 17:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.244 uVs 17:56:20 Integrated Voltage Measurement... 17:56:29 Voltage Offset Correction: v_off_ini = 228.140 uV, v_off_fin = 249.476 uV 17:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.707 uVs 17:56:29 Integrated Voltage Measurement... 17:56:38 Voltage Offset Correction: v_off_ini = 240.429 uV, v_off_fin = 231.763 uV 17:56:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.825 uVs 17:56:38 Integrated Voltage Measurement... 17:56:47 Voltage Offset Correction: v_off_ini = 243.884 uV, v_off_fin = 247.850 uV 17:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.909 uVs 17:56:51 I1Y Average and RMS of Measurements VT = -144.787 +- 3.055 uVs I1Y = -28.958 +- 0.610 uTm 17:56:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:56:58 Integrated Voltage Measurement... 17:57:07 Voltage Offset Correction: v_off_ini = 247.151 uV, v_off_fin = 236.110 uV 17:57:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.538 uVs 17:57:07 Integrated Voltage Measurement... 17:57:16 Voltage Offset Correction: v_off_ini = 226.094 uV, v_off_fin = 236.928 uV 17:57:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.946 uVs 17:57:17 Integrated Voltage Measurement... 17:57:25 Voltage Offset Correction: v_off_ini = 230.017 uV, v_off_fin = 210.235 uV 17:57:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.509 uVs 17:57:26 Integrated Voltage Measurement... 17:57:34 Voltage Offset Correction: v_off_ini = 218.832 uV, v_off_fin = 235.436 uV 17:57:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.782 uVs 17:57:35 Integrated Voltage Measurement... 17:57:44 Voltage Offset Correction: v_off_ini = 223.279 uV, v_off_fin = 223.254 uV 17:57:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.900 uVs 17:57:44 Integrated Voltage Measurement... 17:57:53 Voltage Offset Correction: v_off_ini = 221.296 uV, v_off_fin = 228.137 uV 17:57:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.440 uVs 17:57:55 I2X Average and RMS of Measurements VT = -130.352 +- 0.809 uVs I2X = 11.992 +- 0.075 uTm^2 17:58:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:58:03 Integrated Voltage Measurement... 17:58:12 Voltage Offset Correction: v_off_ini = 235.111 uV, v_off_fin = 213.619 uV 17:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.846 uVs 17:58:12 Integrated Voltage Measurement... 17:58:21 Voltage Offset Correction: v_off_ini = 213.648 uV, v_off_fin = 211.113 uV 17:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.372 uVs 17:58:21 Integrated Voltage Measurement... 17:58:30 Voltage Offset Correction: v_off_ini = 215.050 uV, v_off_fin = 211.933 uV 17:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.981 uVs 17:58:30 Integrated Voltage Measurement... 17:58:39 Voltage Offset Correction: v_off_ini = 214.801 uV, v_off_fin = 218.169 uV 17:58:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.576 uVs 17:58:39 Integrated Voltage Measurement... 17:58:48 Voltage Offset Correction: v_off_ini = 222.757 uV, v_off_fin = 218.305 uV 17:58:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.974 uVs 17:58:48 Integrated Voltage Measurement... 17:58:57 Voltage Offset Correction: v_off_ini = 205.530 uV, v_off_fin = 220.371 uV 17:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.294 uVs 17:58:59 I2Y Average and RMS of Measurements VT = -273.674 +- 11.061 uVs I2Y = -25.178 +- 1.018 uTm^2 17:59:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:59:08 Integrated Voltage Measurement... 17:59:17 Voltage Offset Correction: v_off_ini = 211.139 uV, v_off_fin = 203.387 uV 17:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.072 uVs 17:59:17 Integrated Voltage Measurement... 17:59:26 Voltage Offset Correction: v_off_ini = 215.509 uV, v_off_fin = 209.695 uV 17:59:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.908 uVs 17:59:26 Integrated Voltage Measurement... 17:59:35 Voltage Offset Correction: v_off_ini = 229.512 uV, v_off_fin = 217.558 uV 17:59:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.337 uVs 17:59:35 Integrated Voltage Measurement... 17:59:44 Voltage Offset Correction: v_off_ini = 211.298 uV, v_off_fin = 221.838 uV 17:59:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.541 uVs 17:59:44 Integrated Voltage Measurement... 17:59:53 Voltage Offset Correction: v_off_ini = 216.518 uV, v_off_fin = 207.106 uV 17:59:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.701 uVs 17:59:53 Integrated Voltage Measurement... 18:00:02 Voltage Offset Correction: v_off_ini = 217.673 uV, v_off_fin = 211.600 uV 18:00:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.902 uVs 18:00:06 I1X Average and RMS of Measurements VT = -124.243 +- 2.449 uVs I1X = 24.849 +- 0.490 uTm 18:00:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:00:13 Integrated Voltage Measurement... 18:00:22 Voltage Offset Correction: v_off_ini = 215.691 uV, v_off_fin = 209.435 uV 18:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -133.203 uVs 18:00:22 Integrated Voltage Measurement... 18:00:31 Voltage Offset Correction: v_off_ini = 214.992 uV, v_off_fin = 227.022 uV 18:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 128.081 uVs 18:00:31 Integrated Voltage Measurement... 18:00:40 Voltage Offset Correction: v_off_ini = 222.604 uV, v_off_fin = 204.748 uV 18:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.079 uVs 18:00:40 Integrated Voltage Measurement... 18:00:49 Voltage Offset Correction: v_off_ini = 218.806 uV, v_off_fin = 223.358 uV 18:00:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 115.144 uVs 18:00:49 Integrated Voltage Measurement... 18:00:58 Voltage Offset Correction: v_off_ini = 202.493 uV, v_off_fin = 196.057 uV 18:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -122.802 uVs 18:00:58 Integrated Voltage Measurement... 18:01:07 Voltage Offset Correction: v_off_ini = 213.807 uV, v_off_fin = 229.954 uV 18:01:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 119.658 uVs 18:01:11 I1Y Average and RMS of Measurements VT = -124.661 +- 4.244 uVs I1Y = -24.932 +- 0.849 uTm 18:01:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:01:19 Integrated Voltage Measurement... 18:01:28 Voltage Offset Correction: v_off_ini = 220.744 uV, v_off_fin = 207.106 uV 18:01:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.081 uVs 18:01:28 Integrated Voltage Measurement... 18:01:37 Voltage Offset Correction: v_off_ini = 212.402 uV, v_off_fin = 221.079 uV 18:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.699 uVs 18:01:37 Integrated Voltage Measurement... 18:01:46 Voltage Offset Correction: v_off_ini = 227.839 uV, v_off_fin = 224.775 uV 18:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.848 uVs 18:01:46 Integrated Voltage Measurement... 18:01:55 Voltage Offset Correction: v_off_ini = 232.855 uV, v_off_fin = 242.260 uV 18:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.572 uVs 18:01:55 Integrated Voltage Measurement... 18:02:04 Voltage Offset Correction: v_off_ini = 218.284 uV, v_off_fin = 214.215 uV 18:02:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.805 uVs 18:02:04 Integrated Voltage Measurement... 18:02:13 Voltage Offset Correction: v_off_ini = 221.292 uV, v_off_fin = 233.311 uV 18:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.743 uVs 18:02:15 I2X Average and RMS of Measurements VT = -122.791 +- 3.649 uVs I2X = 11.297 +- 0.336 uTm^2 18:02:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:02:23 Integrated Voltage Measurement... 18:02:32 Voltage Offset Correction: v_off_ini = 218.438 uV, v_off_fin = 220.309 uV 18:02:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.484 uVs 18:02:32 Integrated Voltage Measurement... 18:02:41 Voltage Offset Correction: v_off_ini = 224.096 uV, v_off_fin = 221.210 uV 18:02:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.461 uVs 18:02:41 Integrated Voltage Measurement... 18:02:50 Voltage Offset Correction: v_off_ini = 237.257 uV, v_off_fin = 220.344 uV 18:02:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.032 uVs 18:02:50 Integrated Voltage Measurement... 18:02:59 Voltage Offset Correction: v_off_ini = 219.940 uV, v_off_fin = 219.271 uV 18:02:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.216 uVs 18:02:59 Integrated Voltage Measurement... 18:03:08 Voltage Offset Correction: v_off_ini = 208.988 uV, v_off_fin = 194.929 uV 18:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.333 uVs 18:03:08 Integrated Voltage Measurement... 18:03:17 Voltage Offset Correction: v_off_ini = 206.507 uV, v_off_fin = 207.742 uV 18:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.479 uVs 18:03:19 I2Y Average and RMS of Measurements VT = -256.834 +- 3.124 uVs I2Y = -23.629 +- 0.287 uTm^2 18:03:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:03:31 Integrated Voltage Measurement... 18:03:40 Voltage Offset Correction: v_off_ini = 221.026 uV, v_off_fin = 213.296 uV 18:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.422 uVs 18:03:41 Integrated Voltage Measurement... 18:03:49 Voltage Offset Correction: v_off_ini = 210.012 uV, v_off_fin = 233.307 uV 18:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.365 uVs 18:03:50 Integrated Voltage Measurement... 18:03:58 Voltage Offset Correction: v_off_ini = 218.382 uV, v_off_fin = 219.517 uV 18:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.285 uVs 18:03:58 Integrated Voltage Measurement... 18:04:07 Voltage Offset Correction: v_off_ini = 234.712 uV, v_off_fin = 225.381 uV 18:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.093 uVs 18:04:08 Integrated Voltage Measurement... 18:04:16 Voltage Offset Correction: v_off_ini = 234.830 uV, v_off_fin = 227.167 uV 18:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.808 uVs 18:04:17 Integrated Voltage Measurement... 18:04:25 Voltage Offset Correction: v_off_ini = 229.920 uV, v_off_fin = 234.660 uV 18:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.614 uVs 18:04:30 I1X Average and RMS of Measurements VT = -97.098 +- 2.251 uVs I1X = 19.420 +- 0.450 uTm 18:04:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:04:36 Integrated Voltage Measurement... 18:04:45 Voltage Offset Correction: v_off_ini = 208.241 uV, v_off_fin = 202.102 uV 18:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -138.847 uVs 18:04:46 Integrated Voltage Measurement... 18:04:54 Voltage Offset Correction: v_off_ini = 214.143 uV, v_off_fin = 223.597 uV 18:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.249 uVs 18:04:55 Integrated Voltage Measurement... 18:05:03 Voltage Offset Correction: v_off_ini = 207.107 uV, v_off_fin = 206.103 uV 18:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.702 uVs 18:05:04 Integrated Voltage Measurement... 18:05:12 Voltage Offset Correction: v_off_ini = 215.823 uV, v_off_fin = 240.157 uV 18:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.823 uVs 18:05:13 Integrated Voltage Measurement... 18:05:21 Voltage Offset Correction: v_off_ini = 218.462 uV, v_off_fin = 204.789 uV 18:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.178 uVs 18:05:21 Integrated Voltage Measurement... 18:05:30 Voltage Offset Correction: v_off_ini = 218.359 uV, v_off_fin = 222.849 uV 18:05:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 148.027 uVs 18:05:35 I1Y Average and RMS of Measurements VT = -147.971 +- 2.548 uVs I1Y = -29.594 +- 0.510 uTm 18:05:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:05:40 Integrated Voltage Measurement... 18:05:49 Voltage Offset Correction: v_off_ini = 207.570 uV, v_off_fin = 218.207 uV 18:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.619 uVs 18:05:49 Integrated Voltage Measurement... 18:05:58 Voltage Offset Correction: v_off_ini = 222.068 uV, v_off_fin = 227.033 uV 18:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.096 uVs 18:05:58 Integrated Voltage Measurement... 18:06:07 Voltage Offset Correction: v_off_ini = 209.826 uV, v_off_fin = 186.297 uV 18:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.253 uVs 18:06:07 Integrated Voltage Measurement... 18:06:16 Voltage Offset Correction: v_off_ini = 201.634 uV, v_off_fin = 199.973 uV 18:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.194 uVs 18:06:16 Integrated Voltage Measurement... 18:06:25 Voltage Offset Correction: v_off_ini = 189.028 uV, v_off_fin = 187.897 uV 18:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.129 uVs 18:06:25 Integrated Voltage Measurement... 18:06:34 Voltage Offset Correction: v_off_ini = 213.137 uV, v_off_fin = 220.176 uV 18:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.905 uVs 18:06:36 I2X Average and RMS of Measurements VT = -90.866 +- 2.502 uVs I2X = 8.360 +- 0.230 uTm^2 18:06:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:06:41 Integrated Voltage Measurement... 18:06:50 Voltage Offset Correction: v_off_ini = 207.322 uV, v_off_fin = 201.853 uV 18:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.037 uVs 18:06:50 Integrated Voltage Measurement... 18:06:59 Voltage Offset Correction: v_off_ini = 205.771 uV, v_off_fin = 200.791 uV 18:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.191 uVs 18:06:59 Integrated Voltage Measurement... 18:07:08 Voltage Offset Correction: v_off_ini = 205.714 uV, v_off_fin = 201.052 uV 18:07:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.445 uVs 18:07:08 Integrated Voltage Measurement... 18:07:17 Voltage Offset Correction: v_off_ini = 198.594 uV, v_off_fin = 206.136 uV 18:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.743 uVs 18:07:17 Integrated Voltage Measurement... 18:07:26 Voltage Offset Correction: v_off_ini = 211.767 uV, v_off_fin = 212.682 uV 18:07:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.451 uVs 18:07:26 Integrated Voltage Measurement... 18:07:35 Voltage Offset Correction: v_off_ini = 216.145 uV, v_off_fin = 222.365 uV 18:07:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.157 uVs 18:07:38 I2Y Average and RMS of Measurements VT = -289.671 +- 2.528 uVs I2Y = -26.650 +- 0.233 uTm^2 18:07:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:07:46 Integrated Voltage Measurement... 18:07:55 Voltage Offset Correction: v_off_ini = 202.183 uV, v_off_fin = 206.966 uV 18:07:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.772 uVs 18:07:55 Integrated Voltage Measurement... 18:08:04 Voltage Offset Correction: v_off_ini = 221.186 uV, v_off_fin = 211.713 uV 18:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.447 uVs 18:08:04 Integrated Voltage Measurement... 18:08:13 Voltage Offset Correction: v_off_ini = 209.790 uV, v_off_fin = 197.962 uV 18:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.447 uVs 18:08:13 Integrated Voltage Measurement... 18:08:22 Voltage Offset Correction: v_off_ini = 211.526 uV, v_off_fin = 211.764 uV 18:08:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.908 uVs 18:08:22 Integrated Voltage Measurement... 18:08:31 Voltage Offset Correction: v_off_ini = 218.445 uV, v_off_fin = 209.358 uV 18:08:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.122 uVs 18:08:31 Integrated Voltage Measurement... 18:08:40 Voltage Offset Correction: v_off_ini = 215.791 uV, v_off_fin = 221.864 uV 18:08:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.420 uVs 18:08:44 I1X Average and RMS of Measurements VT = -106.019 +- 5.338 uVs I1X = 21.204 +- 1.068 uTm 18:08:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:08:51 Integrated Voltage Measurement... 18:09:00 Voltage Offset Correction: v_off_ini = 193.465 uV, v_off_fin = 196.888 uV 18:09:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.950 uVs 18:09:00 Integrated Voltage Measurement... 18:09:09 Voltage Offset Correction: v_off_ini = 200.897 uV, v_off_fin = 218.600 uV 18:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.064 uVs 18:09:09 Integrated Voltage Measurement... 18:09:18 Voltage Offset Correction: v_off_ini = 217.232 uV, v_off_fin = 208.897 uV 18:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -143.633 uVs 18:09:18 Integrated Voltage Measurement... 18:09:27 Voltage Offset Correction: v_off_ini = 218.509 uV, v_off_fin = 221.265 uV 18:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.181 uVs 18:09:27 Integrated Voltage Measurement... 18:09:36 Voltage Offset Correction: v_off_ini = 218.708 uV, v_off_fin = 219.976 uV 18:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.531 uVs 18:09:36 Integrated Voltage Measurement... 18:09:45 Voltage Offset Correction: v_off_ini = 237.385 uV, v_off_fin = 245.599 uV 18:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.742 uVs 18:09:49 I1Y Average and RMS of Measurements VT = -155.183 +- 4.543 uVs I1Y = -31.037 +- 0.909 uTm 18:09:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:09:55 Integrated Voltage Measurement... 18:10:04 Voltage Offset Correction: v_off_ini = 234.546 uV, v_off_fin = 225.953 uV 18:10:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.726 uVs 18:10:04 Integrated Voltage Measurement... 18:10:13 Voltage Offset Correction: v_off_ini = 221.393 uV, v_off_fin = 240.596 uV 18:10:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.476 uVs 18:10:13 Integrated Voltage Measurement... 18:10:22 Voltage Offset Correction: v_off_ini = 227.081 uV, v_off_fin = 212.619 uV 18:10:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -104.194 uVs 18:10:22 Integrated Voltage Measurement... 18:10:31 Voltage Offset Correction: v_off_ini = 218.943 uV, v_off_fin = 234.704 uV 18:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.110 uVs 18:10:31 Integrated Voltage Measurement... 18:10:40 Voltage Offset Correction: v_off_ini = 226.745 uV, v_off_fin = 211.145 uV 18:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.721 uVs 18:10:40 Integrated Voltage Measurement... 18:10:49 Voltage Offset Correction: v_off_ini = 220.849 uV, v_off_fin = 219.279 uV 18:10:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.904 uVs 18:10:51 I2X Average and RMS of Measurements VT = -97.522 +- 1.518 uVs I2X = 8.973 +- 0.139 uTm^2 18:10:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:10:56 Integrated Voltage Measurement... 18:11:05 Voltage Offset Correction: v_off_ini = 206.620 uV, v_off_fin = 207.575 uV 18:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.252 uVs 18:11:05 Integrated Voltage Measurement... 18:11:14 Voltage Offset Correction: v_off_ini = 216.874 uV, v_off_fin = 198.578 uV 18:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.856 uVs 18:11:14 Integrated Voltage Measurement... 18:11:23 Voltage Offset Correction: v_off_ini = 196.599 uV, v_off_fin = 195.863 uV 18:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.935 uVs 18:11:23 Integrated Voltage Measurement... 18:11:32 Voltage Offset Correction: v_off_ini = 191.863 uV, v_off_fin = 197.250 uV 18:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.115 uVs 18:11:32 Integrated Voltage Measurement... 18:11:41 Voltage Offset Correction: v_off_ini = 185.976 uV, v_off_fin = 190.058 uV 18:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.762 uVs 18:11:41 Integrated Voltage Measurement... 18:11:50 Voltage Offset Correction: v_off_ini = 194.199 uV, v_off_fin = 192.885 uV 18:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.065 uVs 18:11:53 I2Y Average and RMS of Measurements VT = -287.331 +- 6.807 uVs I2Y = -26.434 +- 0.626 uTm^2 18:11:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:12:01 Integrated Voltage Measurement... 18:12:10 Voltage Offset Correction: v_off_ini = 185.867 uV, v_off_fin = 197.591 uV 18:12:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -120.742 uVs 18:12:10 Integrated Voltage Measurement... 18:12:19 Voltage Offset Correction: v_off_ini = 187.715 uV, v_off_fin = 187.161 uV 18:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.873 uVs 18:12:19 Integrated Voltage Measurement... 18:12:28 Voltage Offset Correction: v_off_ini = 187.252 uV, v_off_fin = 190.241 uV 18:12:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.316 uVs 18:12:28 Integrated Voltage Measurement... 18:12:37 Voltage Offset Correction: v_off_ini = 177.736 uV, v_off_fin = 189.821 uV 18:12:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.957 uVs 18:12:37 Integrated Voltage Measurement... 18:12:46 Voltage Offset Correction: v_off_ini = 187.539 uV, v_off_fin = 191.997 uV 18:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.107 uVs 18:12:46 Integrated Voltage Measurement... 18:12:55 Voltage Offset Correction: v_off_ini = 195.413 uV, v_off_fin = 201.180 uV 18:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.222 uVs 18:13:00 I1X Average and RMS of Measurements VT = -119.536 +- 4.827 uVs I1X = 23.908 +- 0.965 uTm 18:13:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:13:06 Integrated Voltage Measurement... 18:13:15 Voltage Offset Correction: v_off_ini = 192.788 uV, v_off_fin = 188.926 uV 18:13:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.001 uVs 18:13:15 Integrated Voltage Measurement... 18:13:24 Voltage Offset Correction: v_off_ini = 199.285 uV, v_off_fin = 202.561 uV 18:13:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.220 uVs 18:13:24 Integrated Voltage Measurement... 18:13:33 Voltage Offset Correction: v_off_ini = 201.042 uV, v_off_fin = 191.981 uV 18:13:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.271 uVs 18:13:33 Integrated Voltage Measurement... 18:13:42 Voltage Offset Correction: v_off_ini = 190.175 uV, v_off_fin = 203.307 uV 18:13:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.041 uVs 18:13:42 Integrated Voltage Measurement... 18:13:51 Voltage Offset Correction: v_off_ini = 196.971 uV, v_off_fin = 188.014 uV 18:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.783 uVs 18:13:51 Integrated Voltage Measurement... 18:14:00 Voltage Offset Correction: v_off_ini = 184.155 uV, v_off_fin = 193.627 uV 18:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.029 uVs 18:14:04 I1Y Average and RMS of Measurements VT = -154.557 +- 1.189 uVs I1Y = -30.911 +- 0.238 uTm 18:14:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:14:10 Integrated Voltage Measurement... 18:14:19 Voltage Offset Correction: v_off_ini = 186.169 uV, v_off_fin = 177.343 uV 18:14:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.602 uVs 18:14:19 Integrated Voltage Measurement... 18:14:28 Voltage Offset Correction: v_off_ini = 185.385 uV, v_off_fin = 187.328 uV 18:14:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.211 uVs 18:14:28 Integrated Voltage Measurement... 18:14:37 Voltage Offset Correction: v_off_ini = 191.262 uV, v_off_fin = 184.645 uV 18:14:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.831 uVs 18:14:37 Integrated Voltage Measurement... 18:14:46 Voltage Offset Correction: v_off_ini = 181.156 uV, v_off_fin = 188.573 uV 18:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.252 uVs 18:14:46 Integrated Voltage Measurement... 18:14:55 Voltage Offset Correction: v_off_ini = 193.408 uV, v_off_fin = 181.297 uV 18:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.576 uVs 18:14:55 Integrated Voltage Measurement... 18:15:04 Voltage Offset Correction: v_off_ini = 180.735 uV, v_off_fin = 203.447 uV 18:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.467 uVs 18:15:06 I2X Average and RMS of Measurements VT = -118.990 +- 4.950 uVs I2X = 10.947 +- 0.455 uTm^2 18:15:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:15:11 Integrated Voltage Measurement... 18:15:20 Voltage Offset Correction: v_off_ini = 175.740 uV, v_off_fin = 180.644 uV 18:15:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.282 uVs 18:15:20 Integrated Voltage Measurement... 18:15:29 Voltage Offset Correction: v_off_ini = 185.317 uV, v_off_fin = 188.405 uV 18:15:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.978 uVs 18:15:29 Integrated Voltage Measurement... 18:15:38 Voltage Offset Correction: v_off_ini = 187.369 uV, v_off_fin = 177.639 uV 18:15:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.829 uVs 18:15:38 Integrated Voltage Measurement... 18:15:47 Voltage Offset Correction: v_off_ini = 173.249 uV, v_off_fin = 177.068 uV 18:15:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.771 uVs 18:15:47 Integrated Voltage Measurement... 18:15:56 Voltage Offset Correction: v_off_ini = 185.792 uV, v_off_fin = 179.299 uV 18:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.526 uVs 18:15:57 Integrated Voltage Measurement... 18:16:05 Voltage Offset Correction: v_off_ini = 195.597 uV, v_off_fin = 185.159 uV 18:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.201 uVs 18:16:08 I2Y Average and RMS of Measurements VT = -291.431 +- 3.586 uVs I2Y = -26.812 +- 0.330 uTm^2 18:16:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:16:16 Integrated Voltage Measurement... 18:16:25 Voltage Offset Correction: v_off_ini = 163.373 uV, v_off_fin = 179.924 uV 18:16:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -86.946 uVs 18:16:25 Integrated Voltage Measurement... 18:16:34 Voltage Offset Correction: v_off_ini = 191.063 uV, v_off_fin = 195.522 uV 18:16:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.902 uVs 18:16:34 Integrated Voltage Measurement... 18:16:43 Voltage Offset Correction: v_off_ini = 195.663 uV, v_off_fin = 178.821 uV 18:16:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.548 uVs 18:16:43 Integrated Voltage Measurement... 18:16:52 Voltage Offset Correction: v_off_ini = 181.217 uV, v_off_fin = 181.037 uV 18:16:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.254 uVs 18:16:52 Integrated Voltage Measurement... 18:17:01 Voltage Offset Correction: v_off_ini = 168.807 uV, v_off_fin = 162.475 uV 18:17:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.246 uVs 18:17:01 Integrated Voltage Measurement... 18:17:10 Voltage Offset Correction: v_off_ini = 171.369 uV, v_off_fin = 176.439 uV 18:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.811 uVs 18:17:14 I1X Average and RMS of Measurements VT = -106.785 +- 5.610 uVs I1X = 21.358 +- 1.122 uTm 18:17:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:17:21 Integrated Voltage Measurement... 18:17:30 Voltage Offset Correction: v_off_ini = 179.142 uV, v_off_fin = 169.940 uV 18:17:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.684 uVs 18:17:30 Integrated Voltage Measurement... 18:17:39 Voltage Offset Correction: v_off_ini = 178.150 uV, v_off_fin = 191.060 uV 18:17:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.248 uVs 18:17:39 Integrated Voltage Measurement... 18:17:48 Voltage Offset Correction: v_off_ini = 166.377 uV, v_off_fin = 176.557 uV 18:17:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.736 uVs 18:17:48 Integrated Voltage Measurement... 18:17:57 Voltage Offset Correction: v_off_ini = 176.910 uV, v_off_fin = 177.458 uV 18:17:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.232 uVs 18:17:57 Integrated Voltage Measurement... 18:18:06 Voltage Offset Correction: v_off_ini = 167.068 uV, v_off_fin = 145.647 uV 18:18:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.698 uVs 18:18:06 Integrated Voltage Measurement... 18:18:15 Voltage Offset Correction: v_off_ini = 163.593 uV, v_off_fin = 172.271 uV 18:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 142.897 uVs 18:18:19 I1Y Average and RMS of Measurements VT = -155.916 +- 7.492 uVs I1Y = -31.183 +- 1.498 uTm 18:18:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:18:25 Integrated Voltage Measurement... 18:18:34 Voltage Offset Correction: v_off_ini = 161.109 uV, v_off_fin = 149.726 uV 18:18:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -118.456 uVs 18:18:34 Integrated Voltage Measurement... 18:18:43 Voltage Offset Correction: v_off_ini = 159.797 uV, v_off_fin = 158.123 uV 18:18:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.415 uVs 18:18:43 Integrated Voltage Measurement... 18:18:52 Voltage Offset Correction: v_off_ini = 159.326 uV, v_off_fin = 141.323 uV 18:18:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.095 uVs 18:18:52 Integrated Voltage Measurement... 18:19:01 Voltage Offset Correction: v_off_ini = 136.173 uV, v_off_fin = 163.258 uV 18:19:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.850 uVs 18:19:01 Integrated Voltage Measurement... 18:19:10 Voltage Offset Correction: v_off_ini = 151.518 uV, v_off_fin = 137.202 uV 18:19:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.835 uVs 18:19:10 Integrated Voltage Measurement... 18:19:19 Voltage Offset Correction: v_off_ini = 142.379 uV, v_off_fin = 153.548 uV 18:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.329 uVs 18:19:21 I2X Average and RMS of Measurements VT = -119.997 +- 3.519 uVs I2X = 11.040 +- 0.324 uTm^2 18:19:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:19:26 Integrated Voltage Measurement... 18:19:35 Voltage Offset Correction: v_off_ini = 142.817 uV, v_off_fin = 131.342 uV 18:19:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.179 uVs 18:19:35 Integrated Voltage Measurement... 18:19:44 Voltage Offset Correction: v_off_ini = 137.606 uV, v_off_fin = 140.086 uV 18:19:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.189 uVs 18:19:44 Integrated Voltage Measurement... 18:19:53 Voltage Offset Correction: v_off_ini = 132.810 uV, v_off_fin = 145.774 uV 18:19:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.140 uVs 18:19:53 Integrated Voltage Measurement... 18:20:02 Voltage Offset Correction: v_off_ini = 154.952 uV, v_off_fin = 153.650 uV 18:20:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.751 uVs 18:20:02 Integrated Voltage Measurement... 18:20:11 Voltage Offset Correction: v_off_ini = 132.792 uV, v_off_fin = 139.013 uV 18:20:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.006 uVs 18:20:11 Integrated Voltage Measurement... 18:20:20 Voltage Offset Correction: v_off_ini = 154.069 uV, v_off_fin = 145.845 uV 18:20:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.309 uVs 18:20:23 I2Y Average and RMS of Measurements VT = -291.262 +- 4.822 uVs I2Y = -26.796 +- 0.444 uTm^2 18:20:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:20:31 Integrated Voltage Measurement... 18:20:40 Voltage Offset Correction: v_off_ini = 145.612 uV, v_off_fin = 142.696 uV 18:20:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.312 uVs 18:20:40 Integrated Voltage Measurement... 18:20:49 Voltage Offset Correction: v_off_ini = 149.047 uV, v_off_fin = 154.357 uV 18:20:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 108.953 uVs 18:20:49 Integrated Voltage Measurement... 18:20:58 Voltage Offset Correction: v_off_ini = 124.297 uV, v_off_fin = 146.567 uV 18:20:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.035 uVs 18:20:58 Integrated Voltage Measurement... 18:21:07 Voltage Offset Correction: v_off_ini = 146.550 uV, v_off_fin = 138.977 uV 18:21:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.878 uVs 18:21:07 Integrated Voltage Measurement... 18:21:16 Voltage Offset Correction: v_off_ini = 124.850 uV, v_off_fin = 127.899 uV 18:21:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.728 uVs 18:21:16 Integrated Voltage Measurement... 18:21:25 Voltage Offset Correction: v_off_ini = 130.601 uV, v_off_fin = 131.584 uV 18:21:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.586 uVs 18:21:30 I1X Average and RMS of Measurements VT = -118.915 +- 6.887 uVs I1X = 23.784 +- 1.377 uTm 18:21:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:21:36 Integrated Voltage Measurement... 18:21:45 Voltage Offset Correction: v_off_ini = 140.298 uV, v_off_fin = 130.073 uV 18:21:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -160.162 uVs 18:21:45 Integrated Voltage Measurement... 18:21:54 Voltage Offset Correction: v_off_ini = 139.131 uV, v_off_fin = 150.839 uV 18:21:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.470 uVs 18:21:54 Integrated Voltage Measurement... 18:22:03 Voltage Offset Correction: v_off_ini = 135.689 uV, v_off_fin = 137.474 uV 18:22:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -143.910 uVs 18:22:03 Integrated Voltage Measurement... 18:22:12 Voltage Offset Correction: v_off_ini = 137.218 uV, v_off_fin = 150.364 uV 18:22:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.290 uVs 18:22:12 Integrated Voltage Measurement... 18:22:21 Voltage Offset Correction: v_off_ini = 129.279 uV, v_off_fin = 130.908 uV 18:22:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.485 uVs 18:22:21 Integrated Voltage Measurement... 18:22:30 Voltage Offset Correction: v_off_ini = 141.743 uV, v_off_fin = 149.167 uV 18:22:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.241 uVs 18:22:34 I1Y Average and RMS of Measurements VT = -154.760 +- 8.222 uVs I1Y = -30.951 +- 1.643 uTm 18:22:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:22:40 Integrated Voltage Measurement... 18:22:49 Voltage Offset Correction: v_off_ini = 140.533 uV, v_off_fin = 142.875 uV 18:22:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.227 uVs 18:22:49 Integrated Voltage Measurement... 18:22:58 Voltage Offset Correction: v_off_ini = 144.838 uV, v_off_fin = 145.166 uV 18:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.082 uVs 18:22:58 Integrated Voltage Measurement... 18:23:07 Voltage Offset Correction: v_off_ini = 141.386 uV, v_off_fin = 129.787 uV 18:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.300 uVs 18:23:07 Integrated Voltage Measurement... 18:23:16 Voltage Offset Correction: v_off_ini = 137.571 uV, v_off_fin = 149.057 uV 18:23:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.818 uVs 18:23:16 Integrated Voltage Measurement... 18:23:25 Voltage Offset Correction: v_off_ini = 137.415 uV, v_off_fin = 122.290 uV 18:23:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.377 uVs 18:23:25 Integrated Voltage Measurement... 18:23:34 Voltage Offset Correction: v_off_ini = 119.224 uV, v_off_fin = 149.800 uV 18:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.312 uVs 18:23:36 I2X Average and RMS of Measurements VT = -127.686 +- 3.801 uVs I2X = 11.747 +- 0.350 uTm^2 18:23:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:23:41 Integrated Voltage Measurement... 18:23:50 Voltage Offset Correction: v_off_ini = 125.580 uV, v_off_fin = 122.283 uV 18:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.114 uVs 18:23:50 Integrated Voltage Measurement... 18:23:59 Voltage Offset Correction: v_off_ini = 136.662 uV, v_off_fin = 134.420 uV 18:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.267 uVs 18:23:59 Integrated Voltage Measurement... 18:24:08 Voltage Offset Correction: v_off_ini = 134.449 uV, v_off_fin = 125.203 uV 18:24:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.058 uVs 18:24:08 Integrated Voltage Measurement... 18:24:17 Voltage Offset Correction: v_off_ini = 115.945 uV, v_off_fin = 118.714 uV 18:24:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.617 uVs 18:24:17 Integrated Voltage Measurement... 18:24:26 Voltage Offset Correction: v_off_ini = 127.083 uV, v_off_fin = 125.413 uV 18:24:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.530 uVs 18:24:26 Integrated Voltage Measurement... 18:24:35 Voltage Offset Correction: v_off_ini = 134.491 uV, v_off_fin = 134.559 uV 18:24:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.972 uVs 18:24:38 I2Y Average and RMS of Measurements VT = -291.426 +- 8.626 uVs I2Y = -26.811 +- 0.794 uTm^2 18:24:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:24:59 Integrated Voltage Measurement... 18:25:08 Voltage Offset Correction: v_off_ini = 156.761 uV, v_off_fin = 141.611 uV 18:25:08 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -120.695 uVs 18:25:08 Integrated Voltage Measurement... 18:25:17 Voltage Offset Correction: v_off_ini = 152.249 uV, v_off_fin = 150.844 uV 18:25:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.185 uVs 18:25:17 Integrated Voltage Measurement... 18:25:26 Voltage Offset Correction: v_off_ini = 142.778 uV, v_off_fin = 142.034 uV 18:25:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.429 uVs 18:25:26 Integrated Voltage Measurement... 18:25:35 Voltage Offset Correction: v_off_ini = 140.994 uV, v_off_fin = 144.936 uV 18:25:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.796 uVs 18:25:35 Integrated Voltage Measurement... 18:25:44 Voltage Offset Correction: v_off_ini = 141.088 uV, v_off_fin = 138.302 uV 18:25:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.564 uVs 18:25:44 Integrated Voltage Measurement... 18:25:53 Voltage Offset Correction: v_off_ini = 136.415 uV, v_off_fin = 144.180 uV 18:25:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.231 uVs 18:25:57 I1X Average and RMS of Measurements VT = -117.150 +- 12.321 uVs I1X = 23.432 +- 2.464 uTm 18:26:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:26:04 Integrated Voltage Measurement... 18:26:13 Voltage Offset Correction: v_off_ini = 151.375 uV, v_off_fin = 137.110 uV 18:26:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.002 uVs 18:26:13 Integrated Voltage Measurement... 18:26:22 Voltage Offset Correction: v_off_ini = 144.670 uV, v_off_fin = 164.760 uV 18:26:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.565 uVs 18:26:22 Integrated Voltage Measurement... 18:26:31 Voltage Offset Correction: v_off_ini = 159.217 uV, v_off_fin = 144.530 uV 18:26:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.763 uVs 18:26:31 Integrated Voltage Measurement... 18:26:40 Voltage Offset Correction: v_off_ini = 157.866 uV, v_off_fin = 164.655 uV 18:26:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.111 uVs 18:26:40 Integrated Voltage Measurement... 18:26:49 Voltage Offset Correction: v_off_ini = 162.061 uV, v_off_fin = 146.284 uV 18:26:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.147 uVs 18:26:49 Integrated Voltage Measurement... 18:26:58 Voltage Offset Correction: v_off_ini = 154.086 uV, v_off_fin = 159.535 uV 18:26:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.435 uVs 18:27:02 I1Y Average and RMS of Measurements VT = -178.171 +- 3.897 uVs I1Y = -35.634 +- 0.779 uTm 18:27:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:27:10 Integrated Voltage Measurement... 18:27:19 Voltage Offset Correction: v_off_ini = 151.279 uV, v_off_fin = 147.046 uV 18:27:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.325 uVs 18:27:19 Integrated Voltage Measurement... 18:27:28 Voltage Offset Correction: v_off_ini = 147.830 uV, v_off_fin = 158.429 uV 18:27:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.417 uVs 18:27:28 Integrated Voltage Measurement... 18:27:37 Voltage Offset Correction: v_off_ini = 155.060 uV, v_off_fin = 140.927 uV 18:27:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.652 uVs 18:27:37 Integrated Voltage Measurement... 18:27:46 Voltage Offset Correction: v_off_ini = 153.205 uV, v_off_fin = 149.955 uV 18:27:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.793 uVs 18:27:46 Integrated Voltage Measurement... 18:27:55 Voltage Offset Correction: v_off_ini = 143.472 uV, v_off_fin = 136.234 uV 18:27:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.937 uVs 18:27:55 Integrated Voltage Measurement... 18:28:04 Voltage Offset Correction: v_off_ini = 148.481 uV, v_off_fin = 156.124 uV 18:28:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.217 uVs 18:28:07 I2X Average and RMS of Measurements VT = -122.890 +- 7.204 uVs I2X = 11.306 +- 0.663 uTm^2 18:28:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:28:14 Integrated Voltage Measurement... 18:28:23 Voltage Offset Correction: v_off_ini = 149.495 uV, v_off_fin = 145.860 uV 18:28:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.495 uVs 18:28:23 Integrated Voltage Measurement... 18:28:32 Voltage Offset Correction: v_off_ini = 177.438 uV, v_off_fin = 159.663 uV 18:28:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.228 uVs 18:28:33 Integrated Voltage Measurement... 18:28:41 Voltage Offset Correction: v_off_ini = 165.982 uV, v_off_fin = 148.139 uV 18:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.258 uVs 18:28:42 Integrated Voltage Measurement... 18:28:51 Voltage Offset Correction: v_off_ini = 149.262 uV, v_off_fin = 160.863 uV 18:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.040 uVs 18:28:51 Integrated Voltage Measurement... 18:29:00 Voltage Offset Correction: v_off_ini = 161.056 uV, v_off_fin = 162.504 uV 18:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.240 uVs 18:29:00 Integrated Voltage Measurement... 18:29:09 Voltage Offset Correction: v_off_ini = 166.757 uV, v_off_fin = 164.815 uV 18:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.649 uVs 18:29:11 I2Y Average and RMS of Measurements VT = -289.152 +- 3.975 uVs I2Y = -26.602 +- 0.366 uTm^2 18:29:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:29:20 Integrated Voltage Measurement... 18:29:29 Voltage Offset Correction: v_off_ini = 168.388 uV, v_off_fin = 163.977 uV 18:29:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -119.120 uVs 18:29:29 Integrated Voltage Measurement... 18:29:38 Voltage Offset Correction: v_off_ini = 158.561 uV, v_off_fin = 143.217 uV 18:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 136.929 uVs 18:29:38 Integrated Voltage Measurement... 18:29:47 Voltage Offset Correction: v_off_ini = 164.147 uV, v_off_fin = 138.996 uV 18:29:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -118.788 uVs 18:29:47 Integrated Voltage Measurement... 18:29:56 Voltage Offset Correction: v_off_ini = 159.102 uV, v_off_fin = 163.786 uV 18:29:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 120.725 uVs 18:29:56 Integrated Voltage Measurement... 18:30:05 Voltage Offset Correction: v_off_ini = 145.128 uV, v_off_fin = 159.813 uV 18:30:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.429 uVs 18:30:05 Integrated Voltage Measurement... 18:30:14 Voltage Offset Correction: v_off_ini = 148.670 uV, v_off_fin = 162.524 uV 18:30:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.053 uVs 18:30:18 I1X Average and RMS of Measurements VT = -126.341 +- 4.837 uVs I1X = 25.271 +- 0.966 uTm 18:30:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:30:25 Integrated Voltage Measurement... 18:30:34 Voltage Offset Correction: v_off_ini = 161.505 uV, v_off_fin = 158.488 uV 18:30:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.067 uVs 18:30:34 Integrated Voltage Measurement... 18:30:43 Voltage Offset Correction: v_off_ini = 175.543 uV, v_off_fin = 175.856 uV 18:30:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.521 uVs 18:30:43 Integrated Voltage Measurement... 18:30:52 Voltage Offset Correction: v_off_ini = 180.627 uV, v_off_fin = 166.748 uV 18:30:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.486 uVs 18:30:52 Integrated Voltage Measurement... 18:31:01 Voltage Offset Correction: v_off_ini = 162.964 uV, v_off_fin = 161.596 uV 18:31:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.133 uVs 18:31:01 Integrated Voltage Measurement... 18:31:10 Voltage Offset Correction: v_off_ini = 154.882 uV, v_off_fin = 143.655 uV 18:31:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.506 uVs 18:31:10 Integrated Voltage Measurement... 18:31:19 Voltage Offset Correction: v_off_ini = 159.112 uV, v_off_fin = 169.278 uV 18:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.323 uVs 18:31:23 I1Y Average and RMS of Measurements VT = -172.339 +- 3.298 uVs I1Y = -34.468 +- 0.660 uTm 18:31:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:31:31 Integrated Voltage Measurement... 18:31:40 Voltage Offset Correction: v_off_ini = 163.362 uV, v_off_fin = 163.946 uV 18:31:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.576 uVs 18:31:40 Integrated Voltage Measurement... 18:31:49 Voltage Offset Correction: v_off_ini = 166.378 uV, v_off_fin = 150.041 uV 18:31:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.110 uVs 18:31:49 Integrated Voltage Measurement... 18:31:58 Voltage Offset Correction: v_off_ini = 158.918 uV, v_off_fin = 135.481 uV 18:31:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.371 uVs 18:31:58 Integrated Voltage Measurement... 18:32:07 Voltage Offset Correction: v_off_ini = 144.190 uV, v_off_fin = 157.511 uV 18:32:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.058 uVs 18:32:07 Integrated Voltage Measurement... 18:32:16 Voltage Offset Correction: v_off_ini = 148.304 uV, v_off_fin = 136.165 uV 18:32:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.141 uVs 18:32:16 Integrated Voltage Measurement... 18:32:25 Voltage Offset Correction: v_off_ini = 154.555 uV, v_off_fin = 151.385 uV 18:32:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.231 uVs 18:32:27 I2X Average and RMS of Measurements VT = -115.581 +- 2.819 uVs I2X = 10.633 +- 0.260 uTm^2 18:32:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:32:35 Integrated Voltage Measurement... 18:32:44 Voltage Offset Correction: v_off_ini = 166.812 uV, v_off_fin = 163.107 uV 18:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.184 uVs 18:32:44 Integrated Voltage Measurement... 18:32:53 Voltage Offset Correction: v_off_ini = 153.934 uV, v_off_fin = 155.227 uV 18:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.309 uVs 18:32:53 Integrated Voltage Measurement... 18:33:02 Voltage Offset Correction: v_off_ini = 147.142 uV, v_off_fin = 159.126 uV 18:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.866 uVs 18:33:02 Integrated Voltage Measurement... 18:33:11 Voltage Offset Correction: v_off_ini = 154.179 uV, v_off_fin = 154.465 uV 18:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.248 uVs 18:33:11 Integrated Voltage Measurement... 18:33:20 Voltage Offset Correction: v_off_ini = 163.954 uV, v_off_fin = 154.065 uV 18:33:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.234 uVs 18:33:20 Integrated Voltage Measurement... 18:33:29 Voltage Offset Correction: v_off_ini = 163.529 uV, v_off_fin = 164.009 uV 18:33:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.811 uVs 18:33:32 I2Y Average and RMS of Measurements VT = -285.942 +- 3.548 uVs I2Y = -26.307 +- 0.326 uTm^2 18:33:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:33:41 Integrated Voltage Measurement... 18:33:50 Voltage Offset Correction: v_off_ini = 177.061 uV, v_off_fin = 153.627 uV 18:33:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -120.106 uVs 18:33:50 Integrated Voltage Measurement... 18:33:59 Voltage Offset Correction: v_off_ini = 159.274 uV, v_off_fin = 150.512 uV 18:33:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.590 uVs 18:33:59 Integrated Voltage Measurement... 18:34:08 Voltage Offset Correction: v_off_ini = 149.274 uV, v_off_fin = 139.004 uV 18:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.686 uVs 18:34:08 Integrated Voltage Measurement... 18:34:17 Voltage Offset Correction: v_off_ini = 147.555 uV, v_off_fin = 156.706 uV 18:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.723 uVs 18:34:17 Integrated Voltage Measurement... 18:34:26 Voltage Offset Correction: v_off_ini = 153.785 uV, v_off_fin = 160.009 uV 18:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.214 uVs 18:34:26 Integrated Voltage Measurement... 18:34:35 Voltage Offset Correction: v_off_ini = 147.225 uV, v_off_fin = 155.282 uV 18:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.937 uVs 18:34:39 I1X Average and RMS of Measurements VT = -119.709 +- 2.633 uVs I1X = 23.943 +- 0.525 uTm 18:34:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:34:46 Integrated Voltage Measurement... 18:34:55 Voltage Offset Correction: v_off_ini = 135.888 uV, v_off_fin = 124.532 uV 18:34:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -142.977 uVs 18:34:55 Integrated Voltage Measurement... 18:35:04 Voltage Offset Correction: v_off_ini = 135.534 uV, v_off_fin = 152.161 uV 18:35:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.852 uVs 18:35:04 Integrated Voltage Measurement... 18:35:13 Voltage Offset Correction: v_off_ini = 155.011 uV, v_off_fin = 141.403 uV 18:35:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.918 uVs 18:35:13 Integrated Voltage Measurement... 18:35:22 Voltage Offset Correction: v_off_ini = 154.827 uV, v_off_fin = 161.266 uV 18:35:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.192 uVs 18:35:22 Integrated Voltage Measurement... 18:35:31 Voltage Offset Correction: v_off_ini = 156.733 uV, v_off_fin = 152.434 uV 18:35:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.877 uVs 18:35:31 Integrated Voltage Measurement... 18:35:40 Voltage Offset Correction: v_off_ini = 160.470 uV, v_off_fin = 175.247 uV 18:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.481 uVs 18:35:44 I1Y Average and RMS of Measurements VT = -148.549 +- 2.575 uVs I1Y = -29.710 +- 0.515 uTm 18:35:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:35:52 Integrated Voltage Measurement... 18:36:01 Voltage Offset Correction: v_off_ini = 154.894 uV, v_off_fin = 149.777 uV 18:36:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.436 uVs 18:36:01 Integrated Voltage Measurement... 18:36:10 Voltage Offset Correction: v_off_ini = 156.788 uV, v_off_fin = 163.333 uV 18:36:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.525 uVs 18:36:10 Integrated Voltage Measurement... 18:36:19 Voltage Offset Correction: v_off_ini = 169.290 uV, v_off_fin = 154.833 uV 18:36:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.931 uVs 18:36:19 Integrated Voltage Measurement... 18:36:28 Voltage Offset Correction: v_off_ini = 162.717 uV, v_off_fin = 177.557 uV 18:36:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.950 uVs 18:36:28 Integrated Voltage Measurement... 18:36:37 Voltage Offset Correction: v_off_ini = 171.889 uV, v_off_fin = 157.850 uV 18:36:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.522 uVs 18:36:37 Integrated Voltage Measurement... 18:36:46 Voltage Offset Correction: v_off_ini = 167.842 uV, v_off_fin = 174.238 uV 18:36:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.381 uVs 18:36:48 I2X Average and RMS of Measurements VT = -120.957 +- 4.006 uVs I2X = 11.128 +- 0.369 uTm^2 18:36:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:36:56 Integrated Voltage Measurement... 18:37:05 Voltage Offset Correction: v_off_ini = 171.326 uV, v_off_fin = 174.091 uV 18:37:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.935 uVs 18:37:05 Integrated Voltage Measurement... 18:37:14 Voltage Offset Correction: v_off_ini = 174.529 uV, v_off_fin = 169.365 uV 18:37:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.795 uVs 18:37:14 Integrated Voltage Measurement... 18:37:23 Voltage Offset Correction: v_off_ini = 175.201 uV, v_off_fin = 170.842 uV 18:37:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.743 uVs 18:37:23 Integrated Voltage Measurement... 18:37:32 Voltage Offset Correction: v_off_ini = 163.343 uV, v_off_fin = 180.619 uV 18:37:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.656 uVs 18:37:32 Integrated Voltage Measurement... 18:37:41 Voltage Offset Correction: v_off_ini = 178.727 uV, v_off_fin = 168.026 uV 18:37:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.184 uVs 18:37:41 Integrated Voltage Measurement... 18:37:50 Voltage Offset Correction: v_off_ini = 172.646 uV, v_off_fin = 169.823 uV 18:37:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.817 uVs 18:37:53 I2Y Average and RMS of Measurements VT = -273.855 +- 5.361 uVs I2Y = -25.195 +- 0.493 uTm^2 18:37:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:38:01 Integrated Voltage Measurement... 18:38:10 Voltage Offset Correction: v_off_ini = 174.438 uV, v_off_fin = 186.366 uV 18:38:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -143.202 uVs 18:38:10 Integrated Voltage Measurement... 18:38:19 Voltage Offset Correction: v_off_ini = 183.113 uV, v_off_fin = 176.863 uV 18:38:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.861 uVs 18:38:19 Integrated Voltage Measurement... 18:38:28 Voltage Offset Correction: v_off_ini = 166.201 uV, v_off_fin = 160.706 uV 18:38:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.497 uVs 18:38:28 Integrated Voltage Measurement... 18:38:37 Voltage Offset Correction: v_off_ini = 188.655 uV, v_off_fin = 169.961 uV 18:38:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.416 uVs 18:38:37 Integrated Voltage Measurement... 18:38:46 Voltage Offset Correction: v_off_ini = 166.428 uV, v_off_fin = 162.315 uV 18:38:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.019 uVs 18:38:46 Integrated Voltage Measurement... 18:38:55 Voltage Offset Correction: v_off_ini = 165.686 uV, v_off_fin = 156.416 uV 18:38:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.704 uVs 18:39:00 I1X Average and RMS of Measurements VT = -121.950 +- 8.156 uVs I1X = 24.391 +- 1.632 uTm 18:39:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:39:06 Integrated Voltage Measurement... 18:39:15 Voltage Offset Correction: v_off_ini = 191.507 uV, v_off_fin = 173.775 uV 18:39:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -125.779 uVs 18:39:15 Integrated Voltage Measurement... 18:39:24 Voltage Offset Correction: v_off_ini = 191.021 uV, v_off_fin = 185.086 uV 18:39:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.170 uVs 18:39:24 Integrated Voltage Measurement... 18:39:33 Voltage Offset Correction: v_off_ini = 182.988 uV, v_off_fin = 172.677 uV 18:39:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.458 uVs 18:39:33 Integrated Voltage Measurement... 18:39:42 Voltage Offset Correction: v_off_ini = 167.783 uV, v_off_fin = 175.104 uV 18:39:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.046 uVs 18:39:42 Integrated Voltage Measurement... 18:39:51 Voltage Offset Correction: v_off_ini = 162.668 uV, v_off_fin = 159.379 uV 18:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -133.848 uVs 18:39:51 Integrated Voltage Measurement... 18:40:00 Voltage Offset Correction: v_off_ini = 161.528 uV, v_off_fin = 181.445 uV 18:40:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.907 uVs 18:40:04 I1Y Average and RMS of Measurements VT = -141.535 +- 3.644 uVs I1Y = -28.307 +- 0.729 uTm 18:40:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:40:12 Integrated Voltage Measurement... 18:40:21 Voltage Offset Correction: v_off_ini = 168.627 uV, v_off_fin = 164.756 uV 18:40:21 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -120.866 uVs 18:40:21 Integrated Voltage Measurement... 18:40:30 Voltage Offset Correction: v_off_ini = 183.847 uV, v_off_fin = 185.883 uV 18:40:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.717 uVs 18:40:30 Integrated Voltage Measurement... 18:40:39 Voltage Offset Correction: v_off_ini = 179.881 uV, v_off_fin = 171.547 uV 18:40:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.474 uVs 18:40:39 Integrated Voltage Measurement... 18:40:48 Voltage Offset Correction: v_off_ini = 177.965 uV, v_off_fin = 180.464 uV 18:40:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.720 uVs 18:40:48 Integrated Voltage Measurement... 18:40:57 Voltage Offset Correction: v_off_ini = 166.892 uV, v_off_fin = 155.006 uV 18:40:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.792 uVs 18:40:57 Integrated Voltage Measurement... 18:41:06 Voltage Offset Correction: v_off_ini = 154.064 uV, v_off_fin = 173.210 uV 18:41:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.371 uVs 18:41:09 I2X Average and RMS of Measurements VT = -125.490 +- 3.883 uVs I2X = 11.545 +- 0.357 uTm^2 18:41:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:41:16 Integrated Voltage Measurement... 18:41:25 Voltage Offset Correction: v_off_ini = 167.782 uV, v_off_fin = 166.334 uV 18:41:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.916 uVs 18:41:25 Integrated Voltage Measurement... 18:41:34 Voltage Offset Correction: v_off_ini = 176.791 uV, v_off_fin = 168.281 uV 18:41:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.908 uVs 18:41:34 Integrated Voltage Measurement... 18:41:43 Voltage Offset Correction: v_off_ini = 171.973 uV, v_off_fin = 176.626 uV 18:41:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.199 uVs 18:41:43 Integrated Voltage Measurement... 18:41:52 Voltage Offset Correction: v_off_ini = 173.688 uV, v_off_fin = 151.278 uV 18:41:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.327 uVs 18:41:52 Integrated Voltage Measurement... 18:42:01 Voltage Offset Correction: v_off_ini = 167.561 uV, v_off_fin = 154.369 uV 18:42:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.857 uVs 18:42:01 Integrated Voltage Measurement... 18:42:10 Voltage Offset Correction: v_off_ini = 151.844 uV, v_off_fin = 161.296 uV 18:42:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.249 uVs 18:42:13 I2Y Average and RMS of Measurements VT = -254.743 +- 5.375 uVs I2Y = -23.436 +- 0.495 uTm^2 18:42:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:42:22 Integrated Voltage Measurement... 18:42:31 Voltage Offset Correction: v_off_ini = 173.888 uV, v_off_fin = 164.119 uV 18:42:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.732 uVs 18:42:31 Integrated Voltage Measurement... 18:42:40 Voltage Offset Correction: v_off_ini = 168.186 uV, v_off_fin = 166.466 uV 18:42:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.356 uVs 18:42:40 Integrated Voltage Measurement... 18:42:49 Voltage Offset Correction: v_off_ini = 157.335 uV, v_off_fin = 152.670 uV 18:42:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.013 uVs 18:42:49 Integrated Voltage Measurement... 18:42:58 Voltage Offset Correction: v_off_ini = 153.345 uV, v_off_fin = 174.514 uV 18:42:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.945 uVs 18:42:58 Integrated Voltage Measurement... 18:43:07 Voltage Offset Correction: v_off_ini = 162.888 uV, v_off_fin = 168.756 uV 18:43:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.823 uVs 18:43:07 Integrated Voltage Measurement... 18:43:16 Voltage Offset Correction: v_off_ini = 176.211 uV, v_off_fin = 176.085 uV 18:43:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.353 uVs 18:43:20 I1X Average and RMS of Measurements VT = -130.537 +- 11.001 uVs I1X = 26.109 +- 2.200 uTm 18:43:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:43:27 Integrated Voltage Measurement... 18:43:36 Voltage Offset Correction: v_off_ini = 167.598 uV, v_off_fin = 164.518 uV 18:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -121.366 uVs 18:43:36 Integrated Voltage Measurement... 18:43:45 Voltage Offset Correction: v_off_ini = 180.179 uV, v_off_fin = 173.916 uV 18:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 103.092 uVs 18:43:45 Integrated Voltage Measurement... 18:43:54 Voltage Offset Correction: v_off_ini = 175.036 uV, v_off_fin = 172.275 uV 18:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -116.305 uVs 18:43:54 Integrated Voltage Measurement... 18:44:03 Voltage Offset Correction: v_off_ini = 174.784 uV, v_off_fin = 187.444 uV 18:44:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 107.774 uVs 18:44:03 Integrated Voltage Measurement... 18:44:12 Voltage Offset Correction: v_off_ini = 168.229 uV, v_off_fin = 157.308 uV 18:44:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -123.865 uVs 18:44:12 Integrated Voltage Measurement... 18:44:20 Voltage Offset Correction: v_off_ini = 154.149 uV, v_off_fin = 182.207 uV 18:44:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 123.964 uVs 18:44:25 I1Y Average and RMS of Measurements VT = -116.061 +- 5.554 uVs I1Y = -23.213 +- 1.111 uTm 18:44:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:44:32 Integrated Voltage Measurement... 18:44:41 Voltage Offset Correction: v_off_ini = 169.757 uV, v_off_fin = 169.657 uV 18:44:41 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -125.121 uVs 18:44:41 Integrated Voltage Measurement... 18:44:50 Voltage Offset Correction: v_off_ini = 166.265 uV, v_off_fin = 181.675 uV 18:44:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.697 uVs 18:44:50 Integrated Voltage Measurement... 18:44:59 Voltage Offset Correction: v_off_ini = 172.402 uV, v_off_fin = 159.196 uV 18:44:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.604 uVs 18:44:59 Integrated Voltage Measurement... 18:45:08 Voltage Offset Correction: v_off_ini = 158.498 uV, v_off_fin = 178.197 uV 18:45:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.213 uVs 18:45:09 Integrated Voltage Measurement... 18:45:17 Voltage Offset Correction: v_off_ini = 158.492 uV, v_off_fin = 153.266 uV 18:45:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.751 uVs 18:45:18 Integrated Voltage Measurement... 18:45:27 Voltage Offset Correction: v_off_ini = 170.230 uV, v_off_fin = 182.658 uV 18:45:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.258 uVs 18:45:29 I2X Average and RMS of Measurements VT = -133.941 +- 3.892 uVs I2X = 12.322 +- 0.358 uTm^2 18:45:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:45:37 Integrated Voltage Measurement... 18:45:46 Voltage Offset Correction: v_off_ini = 183.927 uV, v_off_fin = 175.750 uV 18:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.990 uVs 18:45:46 Integrated Voltage Measurement... 18:45:55 Voltage Offset Correction: v_off_ini = 177.501 uV, v_off_fin = 176.754 uV 18:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.443 uVs 18:45:55 Integrated Voltage Measurement... 18:46:04 Voltage Offset Correction: v_off_ini = 153.296 uV, v_off_fin = 158.671 uV 18:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.435 uVs 18:46:04 Integrated Voltage Measurement... 18:46:13 Voltage Offset Correction: v_off_ini = 159.798 uV, v_off_fin = 161.241 uV 18:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.310 uVs 18:46:13 Integrated Voltage Measurement... 18:46:22 Voltage Offset Correction: v_off_ini = 162.323 uV, v_off_fin = 166.370 uV 18:46:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.294 uVs 18:46:22 Integrated Voltage Measurement... 18:46:31 Voltage Offset Correction: v_off_ini = 159.475 uV, v_off_fin = 158.796 uV 18:46:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.601 uVs 18:46:33 I2Y Average and RMS of Measurements VT = -244.012 +- 2.127 uVs I2Y = -22.449 +- 0.196 uTm^2 18:46:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:46:45 Integrated Voltage Measurement... 18:46:54 Voltage Offset Correction: v_off_ini = 173.288 uV, v_off_fin = 155.235 uV 18:46:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.325 uVs 18:46:54 Integrated Voltage Measurement... 18:47:03 Voltage Offset Correction: v_off_ini = 165.326 uV, v_off_fin = 172.085 uV 18:47:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.445 uVs 18:47:03 Integrated Voltage Measurement... 18:47:12 Voltage Offset Correction: v_off_ini = 168.009 uV, v_off_fin = 163.833 uV 18:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.278 uVs 18:47:12 Integrated Voltage Measurement... 18:47:21 Voltage Offset Correction: v_off_ini = 150.868 uV, v_off_fin = 166.228 uV 18:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.518 uVs 18:47:21 Integrated Voltage Measurement... 18:47:30 Voltage Offset Correction: v_off_ini = 166.587 uV, v_off_fin = 156.708 uV 18:47:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.344 uVs 18:47:30 Integrated Voltage Measurement... 18:47:39 Voltage Offset Correction: v_off_ini = 163.587 uV, v_off_fin = 166.730 uV 18:47:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.926 uVs 18:47:43 I1X Average and RMS of Measurements VT = -108.806 +- 10.293 uVs I1X = 21.762 +- 2.059 uTm 18:47:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:47:50 Integrated Voltage Measurement... 18:47:59 Voltage Offset Correction: v_off_ini = 177.041 uV, v_off_fin = 162.299 uV 18:47:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.420 uVs 18:47:59 Integrated Voltage Measurement... 18:48:08 Voltage Offset Correction: v_off_ini = 178.559 uV, v_off_fin = 195.946 uV 18:48:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 131.712 uVs 18:48:08 Integrated Voltage Measurement... 18:48:17 Voltage Offset Correction: v_off_ini = 172.986 uV, v_off_fin = 166.421 uV 18:48:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.332 uVs 18:48:17 Integrated Voltage Measurement... 18:48:26 Voltage Offset Correction: v_off_ini = 177.524 uV, v_off_fin = 179.320 uV 18:48:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.696 uVs 18:48:26 Integrated Voltage Measurement... 18:48:35 Voltage Offset Correction: v_off_ini = 165.692 uV, v_off_fin = 152.569 uV 18:48:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.155 uVs 18:48:35 Integrated Voltage Measurement... 18:48:44 Voltage Offset Correction: v_off_ini = 160.084 uV, v_off_fin = 168.134 uV 18:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.003 uVs 18:48:48 I1Y Average and RMS of Measurements VT = -146.053 +- 8.936 uVs I1Y = -29.211 +- 1.787 uTm 18:48:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:48:53 Integrated Voltage Measurement... 18:49:02 Voltage Offset Correction: v_off_ini = 159.502 uV, v_off_fin = 153.893 uV 18:49:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.100 uVs 18:49:02 Integrated Voltage Measurement... 18:49:11 Voltage Offset Correction: v_off_ini = 168.433 uV, v_off_fin = 167.857 uV 18:49:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.404 uVs 18:49:11 Integrated Voltage Measurement... 18:49:20 Voltage Offset Correction: v_off_ini = 158.617 uV, v_off_fin = 169.050 uV 18:49:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.292 uVs 18:49:20 Integrated Voltage Measurement... 18:49:29 Voltage Offset Correction: v_off_ini = 174.993 uV, v_off_fin = 187.401 uV 18:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.150 uVs 18:49:29 Integrated Voltage Measurement... 18:49:38 Voltage Offset Correction: v_off_ini = 176.048 uV, v_off_fin = 180.644 uV 18:49:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.235 uVs 18:49:38 Integrated Voltage Measurement... 18:49:47 Voltage Offset Correction: v_off_ini = 180.899 uV, v_off_fin = 194.924 uV 18:49:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.315 uVs 18:49:50 I2X Average and RMS of Measurements VT = -102.083 +- 14.224 uVs I2X = 9.392 +- 1.309 uTm^2 18:49:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:49:55 Integrated Voltage Measurement... 18:50:04 Voltage Offset Correction: v_off_ini = 164.855 uV, v_off_fin = 161.925 uV 18:50:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.377 uVs 18:50:04 Integrated Voltage Measurement... 18:50:13 Voltage Offset Correction: v_off_ini = 170.547 uV, v_off_fin = 152.961 uV 18:50:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.687 uVs 18:50:13 Integrated Voltage Measurement... 18:50:22 Voltage Offset Correction: v_off_ini = 147.770 uV, v_off_fin = 157.024 uV 18:50:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.701 uVs 18:50:22 Integrated Voltage Measurement... 18:50:31 Voltage Offset Correction: v_off_ini = 160.096 uV, v_off_fin = 157.386 uV 18:50:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.314 uVs 18:50:31 Integrated Voltage Measurement... 18:50:40 Voltage Offset Correction: v_off_ini = 149.964 uV, v_off_fin = 158.873 uV 18:50:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.983 uVs 18:50:40 Integrated Voltage Measurement... 18:50:49 Voltage Offset Correction: v_off_ini = 164.704 uV, v_off_fin = 157.999 uV 18:50:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.523 uVs 18:50:51 I2Y Average and RMS of Measurements VT = -265.431 +- 9.153 uVs I2Y = -24.420 +- 0.842 uTm^2 18:50:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:51:00 Integrated Voltage Measurement... 18:51:09 Voltage Offset Correction: v_off_ini = 159.079 uV, v_off_fin = 149.026 uV 18:51:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.079 uVs 18:51:09 Integrated Voltage Measurement... 18:51:18 Voltage Offset Correction: v_off_ini = 159.252 uV, v_off_fin = 163.288 uV 18:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.972 uVs 18:51:18 Integrated Voltage Measurement... 18:51:27 Voltage Offset Correction: v_off_ini = 150.996 uV, v_off_fin = 160.984 uV 18:51:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.373 uVs 18:51:27 Integrated Voltage Measurement... 18:51:36 Voltage Offset Correction: v_off_ini = 177.951 uV, v_off_fin = 171.735 uV 18:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.096 uVs 18:51:36 Integrated Voltage Measurement... 18:51:45 Voltage Offset Correction: v_off_ini = 159.476 uV, v_off_fin = 150.175 uV 18:51:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.427 uVs 18:51:45 Integrated Voltage Measurement... 18:51:54 Voltage Offset Correction: v_off_ini = 170.912 uV, v_off_fin = 163.487 uV 18:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.388 uVs 18:51:58 I1X Average and RMS of Measurements VT = -114.723 +- 7.471 uVs I1X = 22.945 +- 1.494 uTm 18:52:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:52:05 Integrated Voltage Measurement... 18:52:14 Voltage Offset Correction: v_off_ini = 151.261 uV, v_off_fin = 156.082 uV 18:52:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.791 uVs 18:52:14 Integrated Voltage Measurement... 18:52:23 Voltage Offset Correction: v_off_ini = 155.778 uV, v_off_fin = 169.310 uV 18:52:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.467 uVs 18:52:23 Integrated Voltage Measurement... 18:52:32 Voltage Offset Correction: v_off_ini = 164.009 uV, v_off_fin = 160.670 uV 18:52:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.572 uVs 18:52:32 Integrated Voltage Measurement... 18:52:41 Voltage Offset Correction: v_off_ini = 170.059 uV, v_off_fin = 175.026 uV 18:52:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 130.550 uVs 18:52:41 Integrated Voltage Measurement... 18:52:50 Voltage Offset Correction: v_off_ini = 149.420 uV, v_off_fin = 142.313 uV 18:52:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.278 uVs 18:52:50 Integrated Voltage Measurement... 18:52:59 Voltage Offset Correction: v_off_ini = 159.458 uV, v_off_fin = 158.489 uV 18:52:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.259 uVs 18:53:03 I1Y Average and RMS of Measurements VT = -147.820 +- 3.442 uVs I1Y = -29.564 +- 0.688 uTm 18:53:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:53:08 Integrated Voltage Measurement... 18:53:17 Voltage Offset Correction: v_off_ini = 160.571 uV, v_off_fin = 159.763 uV 18:53:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.418 uVs 18:53:17 Integrated Voltage Measurement... 18:53:26 Voltage Offset Correction: v_off_ini = 154.381 uV, v_off_fin = 154.189 uV 18:53:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.777 uVs 18:53:26 Integrated Voltage Measurement... 18:53:35 Voltage Offset Correction: v_off_ini = 158.922 uV, v_off_fin = 144.025 uV 18:53:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.837 uVs 18:53:35 Integrated Voltage Measurement... 18:53:44 Voltage Offset Correction: v_off_ini = 148.696 uV, v_off_fin = 150.835 uV 18:53:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.613 uVs 18:53:44 Integrated Voltage Measurement... 18:53:53 Voltage Offset Correction: v_off_ini = 144.725 uV, v_off_fin = 138.127 uV 18:53:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.396 uVs 18:53:53 Integrated Voltage Measurement... 18:54:02 Voltage Offset Correction: v_off_ini = 148.370 uV, v_off_fin = 155.323 uV 18:54:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.634 uVs 18:54:05 I2X Average and RMS of Measurements VT = -108.613 +- 13.545 uVs I2X = 9.992 +- 1.246 uTm^2 18:54:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:54:10 Integrated Voltage Measurement... 18:54:19 Voltage Offset Correction: v_off_ini = 144.871 uV, v_off_fin = 148.067 uV 18:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.378 uVs 18:54:19 Integrated Voltage Measurement... 18:54:28 Voltage Offset Correction: v_off_ini = 150.223 uV, v_off_fin = 156.463 uV 18:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.407 uVs 18:54:28 Integrated Voltage Measurement... 18:54:37 Voltage Offset Correction: v_off_ini = 159.097 uV, v_off_fin = 161.873 uV 18:54:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.619 uVs 18:54:37 Integrated Voltage Measurement... 18:54:46 Voltage Offset Correction: v_off_ini = 154.268 uV, v_off_fin = 147.625 uV 18:54:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.467 uVs 18:54:46 Integrated Voltage Measurement... 18:54:55 Voltage Offset Correction: v_off_ini = 156.466 uV, v_off_fin = 151.284 uV 18:54:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.234 uVs 18:54:55 Integrated Voltage Measurement... 18:55:04 Voltage Offset Correction: v_off_ini = 162.567 uV, v_off_fin = 156.738 uV 18:55:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.707 uVs 18:55:06 I2Y Average and RMS of Measurements VT = -266.635 +- 1.655 uVs I2Y = -24.530 +- 0.152 uTm^2 18:55:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:55:15 Integrated Voltage Measurement... 18:55:24 Voltage Offset Correction: v_off_ini = 149.220 uV, v_off_fin = 148.101 uV 18:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.583 uVs 18:55:24 Integrated Voltage Measurement... 18:55:33 Voltage Offset Correction: v_off_ini = 145.731 uV, v_off_fin = 155.956 uV 18:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.740 uVs 18:55:33 Integrated Voltage Measurement... 18:55:42 Voltage Offset Correction: v_off_ini = 159.952 uV, v_off_fin = 145.186 uV 18:55:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.286 uVs 18:55:42 Integrated Voltage Measurement... 18:55:51 Voltage Offset Correction: v_off_ini = 158.691 uV, v_off_fin = 159.282 uV 18:55:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.045 uVs 18:55:51 Integrated Voltage Measurement... 18:56:00 Voltage Offset Correction: v_off_ini = 147.518 uV, v_off_fin = 167.106 uV 18:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.035 uVs 18:56:00 Integrated Voltage Measurement... 18:56:09 Voltage Offset Correction: v_off_ini = 177.426 uV, v_off_fin = 181.786 uV 18:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.567 uVs 18:56:13 I1X Average and RMS of Measurements VT = -113.209 +- 4.340 uVs I1X = 22.643 +- 0.869 uTm 18:56:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:56:20 Integrated Voltage Measurement... 18:56:29 Voltage Offset Correction: v_off_ini = 151.629 uV, v_off_fin = 146.698 uV 18:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.384 uVs 18:56:29 Integrated Voltage Measurement... 18:56:38 Voltage Offset Correction: v_off_ini = 152.695 uV, v_off_fin = 152.613 uV 18:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.279 uVs 18:56:38 Integrated Voltage Measurement... 18:56:47 Voltage Offset Correction: v_off_ini = 147.341 uV, v_off_fin = 141.572 uV 18:56:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.697 uVs 18:56:47 Integrated Voltage Measurement... 18:56:56 Voltage Offset Correction: v_off_ini = 151.548 uV, v_off_fin = 159.755 uV 18:56:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.309 uVs 18:56:56 Integrated Voltage Measurement... 18:57:05 Voltage Offset Correction: v_off_ini = 161.228 uV, v_off_fin = 146.790 uV 18:57:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.978 uVs 18:57:05 Integrated Voltage Measurement... 18:57:14 Voltage Offset Correction: v_off_ini = 141.755 uV, v_off_fin = 154.725 uV 18:57:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.605 uVs 18:57:18 I1Y Average and RMS of Measurements VT = -151.375 +- 4.616 uVs I1Y = -30.275 +- 0.923 uTm 18:57:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:57:23 Integrated Voltage Measurement... 18:57:32 Voltage Offset Correction: v_off_ini = 149.955 uV, v_off_fin = 139.308 uV 18:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.041 uVs 18:57:32 Integrated Voltage Measurement... 18:57:41 Voltage Offset Correction: v_off_ini = 159.860 uV, v_off_fin = 157.587 uV 18:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.244 uVs 18:57:41 Integrated Voltage Measurement... 18:57:50 Voltage Offset Correction: v_off_ini = 139.776 uV, v_off_fin = 142.346 uV 18:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.041 uVs 18:57:50 Integrated Voltage Measurement... 18:57:59 Voltage Offset Correction: v_off_ini = 151.946 uV, v_off_fin = 160.778 uV 18:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.843 uVs 18:57:59 Integrated Voltage Measurement... 18:58:08 Voltage Offset Correction: v_off_ini = 167.563 uV, v_off_fin = 152.853 uV 18:58:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.558 uVs 18:58:08 Integrated Voltage Measurement... 18:58:17 Voltage Offset Correction: v_off_ini = 142.944 uV, v_off_fin = 162.315 uV 18:58:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.002 uVs 18:58:20 I2X Average and RMS of Measurements VT = -125.455 +- 7.479 uVs I2X = 11.542 +- 0.688 uTm^2 18:58:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:58:25 Integrated Voltage Measurement... 18:58:34 Voltage Offset Correction: v_off_ini = 150.901 uV, v_off_fin = 152.654 uV 18:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.156 uVs 18:58:34 Integrated Voltage Measurement... 18:58:43 Voltage Offset Correction: v_off_ini = 156.413 uV, v_off_fin = 149.225 uV 18:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.107 uVs 18:58:43 Integrated Voltage Measurement... 18:58:52 Voltage Offset Correction: v_off_ini = 140.470 uV, v_off_fin = 138.729 uV 18:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.085 uVs 18:58:52 Integrated Voltage Measurement... 18:59:01 Voltage Offset Correction: v_off_ini = 146.638 uV, v_off_fin = 153.796 uV 18:59:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.510 uVs 18:59:01 Integrated Voltage Measurement... 18:59:10 Voltage Offset Correction: v_off_ini = 156.976 uV, v_off_fin = 169.077 uV 18:59:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -268.464 uVs 18:59:10 Integrated Voltage Measurement... 18:59:19 Voltage Offset Correction: v_off_ini = 159.245 uV, v_off_fin = 154.917 uV 18:59:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.020 uVs 18:59:22 I2Y Average and RMS of Measurements VT = -269.224 +- 2.647 uVs I2Y = -24.769 +- 0.244 uTm^2 18:59:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:59:30 Integrated Voltage Measurement... 18:59:39 Voltage Offset Correction: v_off_ini = 166.601 uV, v_off_fin = 158.805 uV 18:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.479 uVs 18:59:39 Integrated Voltage Measurement... 18:59:48 Voltage Offset Correction: v_off_ini = 159.814 uV, v_off_fin = 165.006 uV 18:59:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 125.811 uVs 18:59:48 Integrated Voltage Measurement... 18:59:57 Voltage Offset Correction: v_off_ini = 156.681 uV, v_off_fin = 151.996 uV 18:59:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.916 uVs 18:59:57 Integrated Voltage Measurement... 19:00:06 Voltage Offset Correction: v_off_ini = 159.412 uV, v_off_fin = 170.601 uV 19:00:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.819 uVs 19:00:06 Integrated Voltage Measurement... 19:00:15 Voltage Offset Correction: v_off_ini = 160.592 uV, v_off_fin = 155.848 uV 19:00:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.993 uVs 19:00:15 Integrated Voltage Measurement... 19:00:24 Voltage Offset Correction: v_off_ini = 153.100 uV, v_off_fin = 162.873 uV 19:00:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.980 uVs 19:00:28 I1X Average and RMS of Measurements VT = -125.333 +- 3.278 uVs I1X = 25.067 +- 0.656 uTm 19:00:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:00:35 Integrated Voltage Measurement... 19:00:44 Voltage Offset Correction: v_off_ini = 152.025 uV, v_off_fin = 147.788 uV 19:00:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -138.267 uVs 19:00:44 Integrated Voltage Measurement... 19:00:53 Voltage Offset Correction: v_off_ini = 169.584 uV, v_off_fin = 178.607 uV 19:00:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.029 uVs 19:00:53 Integrated Voltage Measurement... 19:01:02 Voltage Offset Correction: v_off_ini = 165.795 uV, v_off_fin = 169.196 uV 19:01:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.486 uVs 19:01:02 Integrated Voltage Measurement... 19:01:11 Voltage Offset Correction: v_off_ini = 167.487 uV, v_off_fin = 181.396 uV 19:01:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.574 uVs 19:01:11 Integrated Voltage Measurement... 19:01:20 Voltage Offset Correction: v_off_ini = 163.539 uV, v_off_fin = 170.936 uV 19:01:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -130.477 uVs 19:01:20 Integrated Voltage Measurement... 19:01:29 Voltage Offset Correction: v_off_ini = 191.339 uV, v_off_fin = 197.662 uV 19:01:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 135.042 uVs 19:01:33 I1Y Average and RMS of Measurements VT = -142.979 +- 8.703 uVs I1Y = -28.596 +- 1.741 uTm 19:01:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:01:38 Integrated Voltage Measurement... 19:01:47 Voltage Offset Correction: v_off_ini = 161.068 uV, v_off_fin = 156.288 uV 19:01:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -133.372 uVs 19:01:47 Integrated Voltage Measurement... 19:01:56 Voltage Offset Correction: v_off_ini = 169.211 uV, v_off_fin = 176.702 uV 19:01:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.504 uVs 19:01:56 Integrated Voltage Measurement... 19:02:05 Voltage Offset Correction: v_off_ini = 170.007 uV, v_off_fin = 159.434 uV 19:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.305 uVs 19:02:05 Integrated Voltage Measurement... 19:02:14 Voltage Offset Correction: v_off_ini = 174.086 uV, v_off_fin = 178.744 uV 19:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.837 uVs 19:02:14 Integrated Voltage Measurement... 19:02:23 Voltage Offset Correction: v_off_ini = 167.477 uV, v_off_fin = 165.649 uV 19:02:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.323 uVs 19:02:24 Integrated Voltage Measurement... 19:02:32 Voltage Offset Correction: v_off_ini = 174.133 uV, v_off_fin = 180.843 uV 19:02:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.697 uVs 19:02:35 I2X Average and RMS of Measurements VT = -129.673 +- 2.910 uVs I2X = 11.930 +- 0.268 uTm^2 19:02:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:02:40 Integrated Voltage Measurement... 19:02:49 Voltage Offset Correction: v_off_ini = 158.592 uV, v_off_fin = 162.813 uV 19:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.253 uVs 19:02:49 Integrated Voltage Measurement... 19:02:58 Voltage Offset Correction: v_off_ini = 173.158 uV, v_off_fin = 176.110 uV 19:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.795 uVs 19:02:58 Integrated Voltage Measurement... 19:03:07 Voltage Offset Correction: v_off_ini = 173.529 uV, v_off_fin = 159.035 uV 19:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.311 uVs 19:03:07 Integrated Voltage Measurement... 19:03:16 Voltage Offset Correction: v_off_ini = 172.943 uV, v_off_fin = 166.976 uV 19:03:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.802 uVs 19:03:16 Integrated Voltage Measurement... 19:03:25 Voltage Offset Correction: v_off_ini = 159.309 uV, v_off_fin = 176.463 uV 19:03:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.061 uVs 19:03:25 Integrated Voltage Measurement... 19:03:34 Voltage Offset Correction: v_off_ini = 175.087 uV, v_off_fin = 162.496 uV 19:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.458 uVs 19:03:37 I2Y Average and RMS of Measurements VT = -275.113 +- 9.510 uVs I2Y = -25.310 +- 0.875 uTm^2 19:03:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:03:45 Integrated Voltage Measurement... 19:03:54 Voltage Offset Correction: v_off_ini = 187.437 uV, v_off_fin = 176.467 uV 19:03:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -110.463 uVs 19:03:54 Integrated Voltage Measurement... 19:04:03 Voltage Offset Correction: v_off_ini = 183.898 uV, v_off_fin = 183.317 uV 19:04:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.721 uVs 19:04:03 Integrated Voltage Measurement... 19:04:12 Voltage Offset Correction: v_off_ini = 179.977 uV, v_off_fin = 159.079 uV 19:04:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.421 uVs 19:04:12 Integrated Voltage Measurement... 19:04:21 Voltage Offset Correction: v_off_ini = 170.232 uV, v_off_fin = 178.245 uV 19:04:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.402 uVs 19:04:21 Integrated Voltage Measurement... 19:04:30 Voltage Offset Correction: v_off_ini = 172.296 uV, v_off_fin = 159.994 uV 19:04:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.670 uVs 19:04:30 Integrated Voltage Measurement... 19:04:39 Voltage Offset Correction: v_off_ini = 162.753 uV, v_off_fin = 167.707 uV 19:04:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.405 uVs 19:04:43 I1X Average and RMS of Measurements VT = -122.847 +- 4.038 uVs I1X = 24.570 +- 0.807 uTm 19:04:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:04:50 Integrated Voltage Measurement... 19:04:59 Voltage Offset Correction: v_off_ini = 168.457 uV, v_off_fin = 161.174 uV 19:04:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.878 uVs 19:04:59 Integrated Voltage Measurement... 19:05:08 Voltage Offset Correction: v_off_ini = 178.126 uV, v_off_fin = 184.875 uV 19:05:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 141.733 uVs 19:05:08 Integrated Voltage Measurement... 19:05:17 Voltage Offset Correction: v_off_ini = 171.350 uV, v_off_fin = 165.192 uV 19:05:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.299 uVs 19:05:17 Integrated Voltage Measurement... 19:05:26 Voltage Offset Correction: v_off_ini = 175.642 uV, v_off_fin = 193.257 uV 19:05:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.565 uVs 19:05:26 Integrated Voltage Measurement... 19:05:35 Voltage Offset Correction: v_off_ini = 197.131 uV, v_off_fin = 164.209 uV 19:05:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.560 uVs 19:05:35 Integrated Voltage Measurement... 19:05:44 Voltage Offset Correction: v_off_ini = 188.038 uV, v_off_fin = 191.466 uV 19:05:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.212 uVs 19:05:48 I1Y Average and RMS of Measurements VT = -141.041 +- 1.053 uVs I1Y = -28.208 +- 0.211 uTm 19:05:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:05:53 Integrated Voltage Measurement... 19:06:02 Voltage Offset Correction: v_off_ini = 187.503 uV, v_off_fin = 168.459 uV 19:06:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.425 uVs 19:06:02 Integrated Voltage Measurement... 19:06:11 Voltage Offset Correction: v_off_ini = 189.694 uV, v_off_fin = 195.691 uV 19:06:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.395 uVs 19:06:11 Integrated Voltage Measurement... 19:06:20 Voltage Offset Correction: v_off_ini = 194.752 uV, v_off_fin = 189.623 uV 19:06:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.383 uVs 19:06:21 Integrated Voltage Measurement... 19:06:29 Voltage Offset Correction: v_off_ini = 197.515 uV, v_off_fin = 203.040 uV 19:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.555 uVs 19:06:30 Integrated Voltage Measurement... 19:06:39 Voltage Offset Correction: v_off_ini = 203.392 uV, v_off_fin = 194.912 uV 19:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.779 uVs 19:06:39 Integrated Voltage Measurement... 19:06:48 Voltage Offset Correction: v_off_ini = 185.031 uV, v_off_fin = 171.488 uV 19:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.485 uVs 19:06:50 I2X Average and RMS of Measurements VT = -135.337 +- 7.179 uVs I2X = 12.451 +- 0.660 uTm^2 19:06:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:06:55 Integrated Voltage Measurement... 19:07:04 Voltage Offset Correction: v_off_ini = 176.480 uV, v_off_fin = 174.502 uV 19:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.718 uVs 19:07:04 Integrated Voltage Measurement... 19:07:13 Voltage Offset Correction: v_off_ini = 177.992 uV, v_off_fin = 191.215 uV 19:07:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.079 uVs 19:07:13 Integrated Voltage Measurement... 19:07:22 Voltage Offset Correction: v_off_ini = 195.010 uV, v_off_fin = 187.975 uV 19:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.545 uVs 19:07:22 Integrated Voltage Measurement... 19:07:31 Voltage Offset Correction: v_off_ini = 168.410 uV, v_off_fin = 177.145 uV 19:07:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.718 uVs 19:07:31 Integrated Voltage Measurement... 19:07:40 Voltage Offset Correction: v_off_ini = 184.866 uV, v_off_fin = 171.817 uV 19:07:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.325 uVs 19:07:40 Integrated Voltage Measurement... 19:07:49 Voltage Offset Correction: v_off_ini = 167.927 uV, v_off_fin = 165.356 uV 19:07:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.391 uVs 19:07:52 I2Y Average and RMS of Measurements VT = -279.629 +- 2.637 uVs I2Y = -25.726 +- 0.243 uTm^2 19:08:23 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:08:27 Integrated Voltage Measurement... 19:08:36 Voltage Offset Correction: v_off_ini = 186.562 uV, v_off_fin = 180.283 uV 19:08:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.350 uVs 19:08:36 Integrated Voltage Measurement... 19:08:45 Voltage Offset Correction: v_off_ini = 174.152 uV, v_off_fin = 185.224 uV 19:08:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.776 uVs 19:08:45 Integrated Voltage Measurement... 19:08:54 Voltage Offset Correction: v_off_ini = 170.963 uV, v_off_fin = 165.618 uV 19:08:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.476 uVs 19:08:54 Integrated Voltage Measurement... 19:09:03 Voltage Offset Correction: v_off_ini = 167.233 uV, v_off_fin = 184.932 uV 19:09:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 101.662 uVs 19:09:03 Integrated Voltage Measurement... 19:09:12 Voltage Offset Correction: v_off_ini = 186.907 uV, v_off_fin = 188.197 uV 19:09:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.448 uVs 19:09:12 Integrated Voltage Measurement... 19:09:21 Voltage Offset Correction: v_off_ini = 186.765 uV, v_off_fin = 189.926 uV 19:09:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.232 uVs 19:09:26 I1X Average and RMS of Measurements VT = -99.657 +- 5.473 uVs I1X = 19.933 +- 1.093 uTm 19:09:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:09:32 Integrated Voltage Measurement... 19:09:41 Voltage Offset Correction: v_off_ini = 178.167 uV, v_off_fin = 171.686 uV 19:09:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.145 uVs 19:09:41 Integrated Voltage Measurement... 19:09:50 Voltage Offset Correction: v_off_ini = 192.427 uV, v_off_fin = 191.304 uV 19:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.031 uVs 19:09:50 Integrated Voltage Measurement... 19:09:59 Voltage Offset Correction: v_off_ini = 179.432 uV, v_off_fin = 170.362 uV 19:09:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.675 uVs 19:09:59 Integrated Voltage Measurement... 19:10:08 Voltage Offset Correction: v_off_ini = 185.048 uV, v_off_fin = 197.603 uV 19:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.152 uVs 19:10:08 Integrated Voltage Measurement... 19:10:17 Voltage Offset Correction: v_off_ini = 180.727 uV, v_off_fin = 174.805 uV 19:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.426 uVs 19:10:17 Integrated Voltage Measurement... 19:10:26 Voltage Offset Correction: v_off_ini = 173.072 uV, v_off_fin = 177.043 uV 19:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.488 uVs 19:10:31 I1Y Average and RMS of Measurements VT = -211.653 +- 5.325 uVs I1Y = -42.331 +- 1.065 uTm 19:10:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:10:38 Integrated Voltage Measurement... 19:10:47 Voltage Offset Correction: v_off_ini = 171.821 uV, v_off_fin = 174.447 uV 19:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.285 uVs 19:10:47 Integrated Voltage Measurement... 19:10:56 Voltage Offset Correction: v_off_ini = 172.953 uV, v_off_fin = 192.736 uV 19:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.115 uVs 19:10:56 Integrated Voltage Measurement... 19:11:05 Voltage Offset Correction: v_off_ini = 170.875 uV, v_off_fin = 168.377 uV 19:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.828 uVs 19:11:05 Integrated Voltage Measurement... 19:11:14 Voltage Offset Correction: v_off_ini = 168.660 uV, v_off_fin = 183.712 uV 19:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.574 uVs 19:11:14 Integrated Voltage Measurement... 19:11:23 Voltage Offset Correction: v_off_ini = 181.257 uV, v_off_fin = 170.689 uV 19:11:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.871 uVs 19:11:24 Integrated Voltage Measurement... 19:11:33 Voltage Offset Correction: v_off_ini = 171.086 uV, v_off_fin = 178.420 uV 19:11:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.282 uVs 19:11:35 I2X Average and RMS of Measurements VT = -98.992 +- 6.391 uVs I2X = 9.107 +- 0.588 uTm^2 19:11:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:11:43 Integrated Voltage Measurement... 19:11:52 Voltage Offset Correction: v_off_ini = 175.112 uV, v_off_fin = 172.731 uV 19:11:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.902 uVs 19:11:52 Integrated Voltage Measurement... 19:12:01 Voltage Offset Correction: v_off_ini = 166.307 uV, v_off_fin = 161.143 uV 19:12:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.108 uVs 19:12:01 Integrated Voltage Measurement... 19:12:10 Voltage Offset Correction: v_off_ini = 157.425 uV, v_off_fin = 151.805 uV 19:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.691 uVs 19:12:10 Integrated Voltage Measurement... 19:12:19 Voltage Offset Correction: v_off_ini = 168.199 uV, v_off_fin = 172.069 uV 19:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.699 uVs 19:12:19 Integrated Voltage Measurement... 19:12:28 Voltage Offset Correction: v_off_ini = 181.185 uV, v_off_fin = 167.856 uV 19:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.973 uVs 19:12:28 Integrated Voltage Measurement... 19:12:37 Voltage Offset Correction: v_off_ini = 169.123 uV, v_off_fin = 173.168 uV 19:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.190 uVs 19:12:39 I2Y Average and RMS of Measurements VT = -265.927 +- 8.433 uVs I2Y = -24.465 +- 0.776 uTm^2 19:12:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:12:48 Integrated Voltage Measurement... 19:12:57 Voltage Offset Correction: v_off_ini = 169.070 uV, v_off_fin = 164.909 uV 19:12:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.031 uVs 19:12:57 Integrated Voltage Measurement... 19:13:06 Voltage Offset Correction: v_off_ini = 167.448 uV, v_off_fin = 161.441 uV 19:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.529 uVs 19:13:06 Integrated Voltage Measurement... 19:13:15 Voltage Offset Correction: v_off_ini = 171.211 uV, v_off_fin = 167.276 uV 19:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.018 uVs 19:13:15 Integrated Voltage Measurement... 19:13:24 Voltage Offset Correction: v_off_ini = 176.972 uV, v_off_fin = 175.400 uV 19:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.485 uVs 19:13:24 Integrated Voltage Measurement... 19:13:33 Voltage Offset Correction: v_off_ini = 185.046 uV, v_off_fin = 187.599 uV 19:13:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.710 uVs 19:13:33 Integrated Voltage Measurement... 19:13:42 Voltage Offset Correction: v_off_ini = 180.665 uV, v_off_fin = 192.517 uV 19:13:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.390 uVs 19:13:47 I1X Average and RMS of Measurements VT = -99.860 +- 4.605 uVs I1X = 19.972 +- 0.921 uTm 19:13:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:13:53 Integrated Voltage Measurement... 19:14:02 Voltage Offset Correction: v_off_ini = 181.048 uV, v_off_fin = 173.524 uV 19:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.766 uVs 19:14:02 Integrated Voltage Measurement... 19:14:11 Voltage Offset Correction: v_off_ini = 181.335 uV, v_off_fin = 194.117 uV 19:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.006 uVs 19:14:11 Integrated Voltage Measurement... 19:14:20 Voltage Offset Correction: v_off_ini = 178.487 uV, v_off_fin = 170.794 uV 19:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.160 uVs 19:14:20 Integrated Voltage Measurement... 19:14:29 Voltage Offset Correction: v_off_ini = 180.481 uV, v_off_fin = 194.566 uV 19:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.196 uVs 19:14:29 Integrated Voltage Measurement... 19:14:38 Voltage Offset Correction: v_off_ini = 172.732 uV, v_off_fin = 156.129 uV 19:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.831 uVs 19:14:38 Integrated Voltage Measurement... 19:14:47 Voltage Offset Correction: v_off_ini = 168.900 uV, v_off_fin = 174.704 uV 19:14:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.388 uVs 19:14:51 I1Y Average and RMS of Measurements VT = -212.724 +- 8.488 uVs I1Y = -42.545 +- 1.698 uTm 19:14:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:14:59 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = 160.769 uV, v_off_fin = 150.740 uV 19:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.881 uVs 19:15:08 Integrated Voltage Measurement... 19:15:17 Voltage Offset Correction: v_off_ini = 162.371 uV, v_off_fin = 175.212 uV 19:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.357 uVs 19:15:17 Integrated Voltage Measurement... 19:15:26 Voltage Offset Correction: v_off_ini = 167.127 uV, v_off_fin = 160.843 uV 19:15:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.835 uVs 19:15:26 Integrated Voltage Measurement... 19:15:35 Voltage Offset Correction: v_off_ini = 161.798 uV, v_off_fin = 169.113 uV 19:15:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.712 uVs 19:15:35 Integrated Voltage Measurement... 19:15:44 Voltage Offset Correction: v_off_ini = 164.722 uV, v_off_fin = 164.871 uV 19:15:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.547 uVs 19:15:44 Integrated Voltage Measurement... 19:15:53 Voltage Offset Correction: v_off_ini = 169.085 uV, v_off_fin = 179.664 uV 19:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.422 uVs 19:15:56 I2X Average and RMS of Measurements VT = -101.626 +- 6.456 uVs I2X = 9.350 +- 0.594 uTm^2 19:16:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:16:03 Integrated Voltage Measurement... 19:16:12 Voltage Offset Correction: v_off_ini = 169.030 uV, v_off_fin = 160.864 uV 19:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.479 uVs 19:16:13 Integrated Voltage Measurement... 19:16:22 Voltage Offset Correction: v_off_ini = 180.837 uV, v_off_fin = 164.546 uV 19:16:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.105 uVs 19:16:22 Integrated Voltage Measurement... 19:16:31 Voltage Offset Correction: v_off_ini = 168.217 uV, v_off_fin = 159.306 uV 19:16:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.773 uVs 19:16:31 Integrated Voltage Measurement... 19:16:40 Voltage Offset Correction: v_off_ini = 163.288 uV, v_off_fin = 162.807 uV 19:16:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.096 uVs 19:16:40 Integrated Voltage Measurement... 19:16:49 Voltage Offset Correction: v_off_ini = 172.558 uV, v_off_fin = 162.859 uV 19:16:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.511 uVs 19:16:49 Integrated Voltage Measurement... 19:16:58 Voltage Offset Correction: v_off_ini = 164.493 uV, v_off_fin = 162.013 uV 19:16:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.578 uVs 19:17:00 I2Y Average and RMS of Measurements VT = -253.757 +- 4.379 uVs I2Y = -23.346 +- 0.403 uTm^2 19:17:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:17:09 Integrated Voltage Measurement... 19:17:18 Voltage Offset Correction: v_off_ini = 169.973 uV, v_off_fin = 158.835 uV 19:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.182 uVs 19:17:18 Integrated Voltage Measurement... 19:17:27 Voltage Offset Correction: v_off_ini = 150.284 uV, v_off_fin = 153.480 uV 19:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.794 uVs 19:17:27 Integrated Voltage Measurement... 19:17:36 Voltage Offset Correction: v_off_ini = 171.378 uV, v_off_fin = 167.921 uV 19:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.410 uVs 19:17:36 Integrated Voltage Measurement... 19:17:45 Voltage Offset Correction: v_off_ini = 186.420 uV, v_off_fin = 182.083 uV 19:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.796 uVs 19:17:45 Integrated Voltage Measurement... 19:17:54 Voltage Offset Correction: v_off_ini = 172.238 uV, v_off_fin = 164.052 uV 19:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.868 uVs 19:17:54 Integrated Voltage Measurement... 19:18:03 Voltage Offset Correction: v_off_ini = 162.806 uV, v_off_fin = 173.085 uV 19:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.151 uVs 19:18:07 I1X Average and RMS of Measurements VT = -103.367 +- 6.387 uVs I1X = 20.673 +- 1.277 uTm 19:18:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:18:14 Integrated Voltage Measurement... 19:18:23 Voltage Offset Correction: v_off_ini = 168.116 uV, v_off_fin = 160.760 uV 19:18:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.459 uVs 19:18:23 Integrated Voltage Measurement... 19:18:32 Voltage Offset Correction: v_off_ini = 173.920 uV, v_off_fin = 194.917 uV 19:18:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.311 uVs 19:18:32 Integrated Voltage Measurement... 19:18:41 Voltage Offset Correction: v_off_ini = 176.104 uV, v_off_fin = 151.635 uV 19:18:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.457 uVs 19:18:41 Integrated Voltage Measurement... 19:18:50 Voltage Offset Correction: v_off_ini = 162.242 uV, v_off_fin = 172.479 uV 19:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.943 uVs 19:18:50 Integrated Voltage Measurement... 19:18:59 Voltage Offset Correction: v_off_ini = 169.379 uV, v_off_fin = 146.438 uV 19:18:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.367 uVs 19:18:59 Integrated Voltage Measurement... 19:19:08 Voltage Offset Correction: v_off_ini = 152.320 uV, v_off_fin = 159.422 uV 19:19:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.769 uVs 19:19:12 I1Y Average and RMS of Measurements VT = -202.884 +- 3.544 uVs I1Y = -40.577 +- 0.709 uTm 19:19:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:19:20 Integrated Voltage Measurement... 19:19:29 Voltage Offset Correction: v_off_ini = 154.436 uV, v_off_fin = 149.297 uV 19:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.349 uVs 19:19:29 Integrated Voltage Measurement... 19:19:38 Voltage Offset Correction: v_off_ini = 168.126 uV, v_off_fin = 170.472 uV 19:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.021 uVs 19:19:38 Integrated Voltage Measurement... 19:19:47 Voltage Offset Correction: v_off_ini = 175.687 uV, v_off_fin = 153.623 uV 19:19:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.599 uVs 19:19:47 Integrated Voltage Measurement... 19:19:56 Voltage Offset Correction: v_off_ini = 166.600 uV, v_off_fin = 175.695 uV 19:19:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.138 uVs 19:19:56 Integrated Voltage Measurement... 19:20:05 Voltage Offset Correction: v_off_ini = 166.373 uV, v_off_fin = 159.922 uV 19:20:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.832 uVs 19:20:05 Integrated Voltage Measurement... 19:20:14 Voltage Offset Correction: v_off_ini = 169.184 uV, v_off_fin = 171.852 uV 19:20:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.213 uVs 19:20:17 I2X Average and RMS of Measurements VT = -97.192 +- 3.691 uVs I2X = 8.942 +- 0.340 uTm^2 19:20:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:20:24 Integrated Voltage Measurement... 19:20:33 Voltage Offset Correction: v_off_ini = 158.707 uV, v_off_fin = 167.320 uV 19:20:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.345 uVs 19:20:33 Integrated Voltage Measurement... 19:20:42 Voltage Offset Correction: v_off_ini = 162.315 uV, v_off_fin = 154.129 uV 19:20:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.859 uVs 19:20:42 Integrated Voltage Measurement... 19:20:51 Voltage Offset Correction: v_off_ini = 167.207 uV, v_off_fin = 187.438 uV 19:20:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.151 uVs 19:20:51 Integrated Voltage Measurement... 19:21:00 Voltage Offset Correction: v_off_ini = 177.981 uV, v_off_fin = 169.860 uV 19:21:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.462 uVs 19:21:00 Integrated Voltage Measurement... 19:21:09 Voltage Offset Correction: v_off_ini = 172.977 uV, v_off_fin = 164.917 uV 19:21:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.521 uVs 19:21:09 Integrated Voltage Measurement... 19:21:18 Voltage Offset Correction: v_off_ini = 162.306 uV, v_off_fin = 158.141 uV 19:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.872 uVs 19:21:21 I2Y Average and RMS of Measurements VT = -256.035 +- 2.824 uVs I2Y = -23.555 +- 0.260 uTm^2 19:21:25 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:21:30 Integrated Voltage Measurement... 19:21:39 Voltage Offset Correction: v_off_ini = 164.752 uV, v_off_fin = 159.823 uV 19:21:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -85.510 uVs 19:21:39 Integrated Voltage Measurement... 19:21:48 Voltage Offset Correction: v_off_ini = 159.458 uV, v_off_fin = 165.368 uV 19:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.530 uVs 19:21:48 Integrated Voltage Measurement... 19:21:57 Voltage Offset Correction: v_off_ini = 150.833 uV, v_off_fin = 150.227 uV 19:21:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.168 uVs 19:21:57 Integrated Voltage Measurement... 19:22:06 Voltage Offset Correction: v_off_ini = 155.209 uV, v_off_fin = 147.323 uV 19:22:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.874 uVs 19:22:06 Integrated Voltage Measurement... 19:22:15 Voltage Offset Correction: v_off_ini = 159.883 uV, v_off_fin = 148.993 uV 19:22:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.447 uVs 19:22:15 Integrated Voltage Measurement... 19:22:24 Voltage Offset Correction: v_off_ini = 164.503 uV, v_off_fin = 171.653 uV 19:22:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.981 uVs 19:22:28 I1X Average and RMS of Measurements VT = -95.252 +- 1.972 uVs I1X = 19.051 +- 0.394 uTm 19:22:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:22:35 Integrated Voltage Measurement... 19:22:44 Voltage Offset Correction: v_off_ini = 169.752 uV, v_off_fin = 152.660 uV 19:22:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.133 uVs 19:22:44 Integrated Voltage Measurement... 19:22:53 Voltage Offset Correction: v_off_ini = 156.218 uV, v_off_fin = 168.801 uV 19:22:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.089 uVs 19:22:53 Integrated Voltage Measurement... 19:23:02 Voltage Offset Correction: v_off_ini = 160.803 uV, v_off_fin = 156.593 uV 19:23:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.094 uVs 19:23:02 Integrated Voltage Measurement... 19:23:11 Voltage Offset Correction: v_off_ini = 161.863 uV, v_off_fin = 165.241 uV 19:23:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.065 uVs 19:23:11 Integrated Voltage Measurement... 19:23:20 Voltage Offset Correction: v_off_ini = 155.076 uV, v_off_fin = 155.464 uV 19:23:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.209 uVs 19:23:20 Integrated Voltage Measurement... 19:23:29 Voltage Offset Correction: v_off_ini = 164.675 uV, v_off_fin = 163.216 uV 19:23:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.713 uVs 19:23:33 I1Y Average and RMS of Measurements VT = -206.384 +- 3.354 uVs I1Y = -41.277 +- 0.671 uTm 19:23:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:23:41 Integrated Voltage Measurement... 19:23:50 Voltage Offset Correction: v_off_ini = 141.520 uV, v_off_fin = 154.714 uV 19:23:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.933 uVs 19:23:50 Integrated Voltage Measurement... 19:23:59 Voltage Offset Correction: v_off_ini = 155.489 uV, v_off_fin = 163.031 uV 19:23:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.308 uVs 19:23:59 Integrated Voltage Measurement... 19:24:08 Voltage Offset Correction: v_off_ini = 150.546 uV, v_off_fin = 137.153 uV 19:24:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.008 uVs 19:24:08 Integrated Voltage Measurement... 19:24:17 Voltage Offset Correction: v_off_ini = 158.623 uV, v_off_fin = 167.039 uV 19:24:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.741 uVs 19:24:17 Integrated Voltage Measurement... 19:24:26 Voltage Offset Correction: v_off_ini = 170.985 uV, v_off_fin = 152.022 uV 19:24:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.576 uVs 19:24:26 Integrated Voltage Measurement... 19:24:35 Voltage Offset Correction: v_off_ini = 156.891 uV, v_off_fin = 162.962 uV 19:24:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.229 uVs 19:24:37 I2X Average and RMS of Measurements VT = -108.466 +- 3.642 uVs I2X = 9.979 +- 0.335 uTm^2 19:24:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:24:45 Integrated Voltage Measurement... 19:24:54 Voltage Offset Correction: v_off_ini = 162.054 uV, v_off_fin = 158.553 uV 19:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.851 uVs 19:24:54 Integrated Voltage Measurement... 19:25:03 Voltage Offset Correction: v_off_ini = 157.241 uV, v_off_fin = 170.068 uV 19:25:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.676 uVs 19:25:03 Integrated Voltage Measurement... 19:25:12 Voltage Offset Correction: v_off_ini = 167.510 uV, v_off_fin = 174.993 uV 19:25:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.275 uVs 19:25:12 Integrated Voltage Measurement... 19:25:21 Voltage Offset Correction: v_off_ini = 167.584 uV, v_off_fin = 167.244 uV 19:25:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.006 uVs 19:25:21 Integrated Voltage Measurement... 19:25:30 Voltage Offset Correction: v_off_ini = 169.421 uV, v_off_fin = 161.254 uV 19:25:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.242 uVs 19:25:30 Integrated Voltage Measurement... 19:25:39 Voltage Offset Correction: v_off_ini = 165.305 uV, v_off_fin = 160.059 uV 19:25:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.475 uVs 19:25:42 I2Y Average and RMS of Measurements VT = -258.254 +- 2.629 uVs I2Y = -23.759 +- 0.242 uTm^2 19:25:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:25:50 Integrated Voltage Measurement... 19:25:59 Voltage Offset Correction: v_off_ini = 173.347 uV, v_off_fin = 156.749 uV 19:25:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.372 uVs 19:25:59 Integrated Voltage Measurement... 19:26:08 Voltage Offset Correction: v_off_ini = 147.142 uV, v_off_fin = 157.582 uV 19:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.330 uVs 19:26:08 Integrated Voltage Measurement... 19:26:17 Voltage Offset Correction: v_off_ini = 151.812 uV, v_off_fin = 150.647 uV 19:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.735 uVs 19:26:18 Integrated Voltage Measurement... 19:26:26 Voltage Offset Correction: v_off_ini = 161.014 uV, v_off_fin = 159.501 uV 19:26:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.144 uVs 19:26:27 Integrated Voltage Measurement... 19:26:35 Voltage Offset Correction: v_off_ini = 171.121 uV, v_off_fin = 173.091 uV 19:26:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.351 uVs 19:26:36 Integrated Voltage Measurement... 19:26:44 Voltage Offset Correction: v_off_ini = 175.341 uV, v_off_fin = 175.967 uV 19:26:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.687 uVs 19:26:49 I1X Average and RMS of Measurements VT = -95.937 +- 9.375 uVs I1X = 19.188 +- 1.875 uTm 19:26:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:26:56 Integrated Voltage Measurement... 19:27:04 Voltage Offset Correction: v_off_ini = 166.345 uV, v_off_fin = 162.745 uV 19:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.502 uVs 19:27:05 Integrated Voltage Measurement... 19:27:13 Voltage Offset Correction: v_off_ini = 167.815 uV, v_off_fin = 182.696 uV 19:27:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.558 uVs 19:27:14 Integrated Voltage Measurement... 19:27:22 Voltage Offset Correction: v_off_ini = 175.451 uV, v_off_fin = 169.778 uV 19:27:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.636 uVs 19:27:23 Integrated Voltage Measurement... 19:27:31 Voltage Offset Correction: v_off_ini = 163.538 uV, v_off_fin = 180.711 uV 19:27:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.431 uVs 19:27:32 Integrated Voltage Measurement... 19:27:40 Voltage Offset Correction: v_off_ini = 176.578 uV, v_off_fin = 163.046 uV 19:27:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.146 uVs 19:27:41 Integrated Voltage Measurement... 19:27:49 Voltage Offset Correction: v_off_ini = 164.042 uV, v_off_fin = 190.285 uV 19:27:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.175 uVs 19:27:54 I1Y Average and RMS of Measurements VT = -199.241 +- 11.980 uVs I1Y = -39.848 +- 2.396 uTm 19:27:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:28:01 Integrated Voltage Measurement... 19:28:10 Voltage Offset Correction: v_off_ini = 160.895 uV, v_off_fin = 160.327 uV 19:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.910 uVs 19:28:10 Integrated Voltage Measurement... 19:28:19 Voltage Offset Correction: v_off_ini = 164.299 uV, v_off_fin = 179.411 uV 19:28:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.673 uVs 19:28:19 Integrated Voltage Measurement... 19:28:28 Voltage Offset Correction: v_off_ini = 174.569 uV, v_off_fin = 157.189 uV 19:28:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.448 uVs 19:28:29 Integrated Voltage Measurement... 19:28:37 Voltage Offset Correction: v_off_ini = 164.194 uV, v_off_fin = 178.222 uV 19:28:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.553 uVs 19:28:38 Integrated Voltage Measurement... 19:28:47 Voltage Offset Correction: v_off_ini = 153.678 uV, v_off_fin = 152.683 uV 19:28:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.461 uVs 19:28:47 Integrated Voltage Measurement... 19:28:56 Voltage Offset Correction: v_off_ini = 169.320 uV, v_off_fin = 173.920 uV 19:28:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.029 uVs 19:28:58 I2X Average and RMS of Measurements VT = -105.013 +- 6.880 uVs I2X = 9.661 +- 0.633 uTm^2 19:29:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:29:06 Integrated Voltage Measurement... 19:29:15 Voltage Offset Correction: v_off_ini = 161.358 uV, v_off_fin = 179.547 uV 19:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.847 uVs 19:29:15 Integrated Voltage Measurement... 19:29:24 Voltage Offset Correction: v_off_ini = 179.910 uV, v_off_fin = 178.939 uV 19:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.780 uVs 19:29:24 Integrated Voltage Measurement... 19:29:33 Voltage Offset Correction: v_off_ini = 165.141 uV, v_off_fin = 175.713 uV 19:29:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.586 uVs 19:29:33 Integrated Voltage Measurement... 19:29:42 Voltage Offset Correction: v_off_ini = 166.119 uV, v_off_fin = 162.452 uV 19:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.165 uVs 19:29:42 Integrated Voltage Measurement... 19:29:51 Voltage Offset Correction: v_off_ini = 165.912 uV, v_off_fin = 169.253 uV 19:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.994 uVs 19:29:51 Integrated Voltage Measurement... 19:30:00 Voltage Offset Correction: v_off_ini = 157.378 uV, v_off_fin = 153.575 uV 19:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.378 uVs 19:30:02 I2Y Average and RMS of Measurements VT = -246.958 +- 5.773 uVs I2Y = -22.720 +- 0.531 uTm^2 19:30:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:30:14 Integrated Voltage Measurement... 19:30:23 Voltage Offset Correction: v_off_ini = 166.141 uV, v_off_fin = 166.622 uV 19:30:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.479 uVs 19:30:23 Integrated Voltage Measurement... 19:30:32 Voltage Offset Correction: v_off_ini = 167.108 uV, v_off_fin = 160.160 uV 19:30:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.183 uVs 19:30:32 Integrated Voltage Measurement... 19:30:41 Voltage Offset Correction: v_off_ini = 158.432 uV, v_off_fin = 149.995 uV 19:30:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.199 uVs 19:30:41 Integrated Voltage Measurement... 19:30:50 Voltage Offset Correction: v_off_ini = 145.394 uV, v_off_fin = 143.057 uV 19:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 99.518 uVs 19:30:50 Integrated Voltage Measurement... 19:30:59 Voltage Offset Correction: v_off_ini = 147.562 uV, v_off_fin = 140.373 uV 19:30:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.175 uVs 19:30:59 Integrated Voltage Measurement... 19:31:08 Voltage Offset Correction: v_off_ini = 152.068 uV, v_off_fin = 152.367 uV 19:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.572 uVs 19:31:13 I1X Average and RMS of Measurements VT = -90.854 +- 6.417 uVs I1X = 18.172 +- 1.284 uTm 19:31:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:31:19 Integrated Voltage Measurement... 19:31:28 Voltage Offset Correction: v_off_ini = 132.136 uV, v_off_fin = 139.654 uV 19:31:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -202.041 uVs 19:31:28 Integrated Voltage Measurement... 19:31:37 Voltage Offset Correction: v_off_ini = 144.109 uV, v_off_fin = 159.980 uV 19:31:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.637 uVs 19:31:37 Integrated Voltage Measurement... 19:31:46 Voltage Offset Correction: v_off_ini = 146.737 uV, v_off_fin = 123.454 uV 19:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.418 uVs 19:31:46 Integrated Voltage Measurement... 19:31:55 Voltage Offset Correction: v_off_ini = 138.380 uV, v_off_fin = 154.206 uV 19:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.045 uVs 19:31:55 Integrated Voltage Measurement... 19:32:04 Voltage Offset Correction: v_off_ini = 138.328 uV, v_off_fin = 134.380 uV 19:32:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.396 uVs 19:32:04 Integrated Voltage Measurement... 19:32:13 Voltage Offset Correction: v_off_ini = 146.709 uV, v_off_fin = 163.172 uV 19:32:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.713 uVs 19:32:18 I1Y Average and RMS of Measurements VT = -203.875 +- 8.941 uVs I1Y = -40.776 +- 1.789 uTm 19:32:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:32:23 Integrated Voltage Measurement... 19:32:32 Voltage Offset Correction: v_off_ini = 135.140 uV, v_off_fin = 135.433 uV 19:32:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.118 uVs 19:32:32 Integrated Voltage Measurement... 19:32:41 Voltage Offset Correction: v_off_ini = 145.704 uV, v_off_fin = 159.557 uV 19:32:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.581 uVs 19:32:41 Integrated Voltage Measurement... 19:32:50 Voltage Offset Correction: v_off_ini = 157.322 uV, v_off_fin = 166.348 uV 19:32:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.730 uVs 19:32:50 Integrated Voltage Measurement... 19:32:59 Voltage Offset Correction: v_off_ini = 166.283 uV, v_off_fin = 160.923 uV 19:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.879 uVs 19:32:59 Integrated Voltage Measurement... 19:33:08 Voltage Offset Correction: v_off_ini = 155.652 uV, v_off_fin = 142.290 uV 19:33:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.598 uVs 19:33:08 Integrated Voltage Measurement... 19:33:17 Voltage Offset Correction: v_off_ini = 151.276 uV, v_off_fin = 158.683 uV 19:33:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.541 uVs 19:33:19 I2X Average and RMS of Measurements VT = -86.574 +- 0.524 uVs I2X = 7.965 +- 0.048 uTm^2 19:33:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:33:24 Integrated Voltage Measurement... 19:33:33 Voltage Offset Correction: v_off_ini = 163.509 uV, v_off_fin = 166.221 uV 19:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.425 uVs 19:33:33 Integrated Voltage Measurement... 19:33:42 Voltage Offset Correction: v_off_ini = 178.425 uV, v_off_fin = 155.787 uV 19:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.803 uVs 19:33:42 Integrated Voltage Measurement... 19:33:51 Voltage Offset Correction: v_off_ini = 168.699 uV, v_off_fin = 158.463 uV 19:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.455 uVs 19:33:52 Integrated Voltage Measurement... 19:34:00 Voltage Offset Correction: v_off_ini = 157.046 uV, v_off_fin = 166.041 uV 19:34:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.828 uVs 19:34:01 Integrated Voltage Measurement... 19:34:10 Voltage Offset Correction: v_off_ini = 176.359 uV, v_off_fin = 166.150 uV 19:34:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.370 uVs 19:34:10 Integrated Voltage Measurement... 19:34:19 Voltage Offset Correction: v_off_ini = 179.479 uV, v_off_fin = 183.247 uV 19:34:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.553 uVs 19:34:21 I2Y Average and RMS of Measurements VT = -259.906 +- 11.976 uVs I2Y = -23.911 +- 1.102 uTm^2 19:34:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:34:29 Integrated Voltage Measurement... 19:34:38 Voltage Offset Correction: v_off_ini = 180.342 uV, v_off_fin = 166.477 uV 19:34:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -111.893 uVs 19:34:38 Integrated Voltage Measurement... 19:34:47 Voltage Offset Correction: v_off_ini = 174.861 uV, v_off_fin = 160.557 uV 19:34:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 91.709 uVs 19:34:47 Integrated Voltage Measurement... 19:34:56 Voltage Offset Correction: v_off_ini = 161.346 uV, v_off_fin = 161.279 uV 19:34:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.294 uVs 19:34:56 Integrated Voltage Measurement... 19:35:05 Voltage Offset Correction: v_off_ini = 188.301 uV, v_off_fin = 173.169 uV 19:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.619 uVs 19:35:05 Integrated Voltage Measurement... 19:35:14 Voltage Offset Correction: v_off_ini = 169.719 uV, v_off_fin = 179.967 uV 19:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.507 uVs 19:35:14 Integrated Voltage Measurement... 19:35:23 Voltage Offset Correction: v_off_ini = 179.076 uV, v_off_fin = 189.231 uV 19:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.622 uVs 19:35:28 I1X Average and RMS of Measurements VT = -93.941 +- 6.270 uVs I1X = 18.789 +- 1.255 uTm 19:35:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:35:34 Integrated Voltage Measurement... 19:35:43 Voltage Offset Correction: v_off_ini = 185.263 uV, v_off_fin = 163.575 uV 19:35:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.183 uVs 19:35:43 Integrated Voltage Measurement... 19:35:52 Voltage Offset Correction: v_off_ini = 172.132 uV, v_off_fin = 180.200 uV 19:35:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.683 uVs 19:35:52 Integrated Voltage Measurement... 19:36:01 Voltage Offset Correction: v_off_ini = 158.733 uV, v_off_fin = 162.587 uV 19:36:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.773 uVs 19:36:01 Integrated Voltage Measurement... 19:36:10 Voltage Offset Correction: v_off_ini = 176.642 uV, v_off_fin = 183.740 uV 19:36:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.131 uVs 19:36:10 Integrated Voltage Measurement... 19:36:19 Voltage Offset Correction: v_off_ini = 168.511 uV, v_off_fin = 158.847 uV 19:36:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.425 uVs 19:36:19 Integrated Voltage Measurement... 19:36:28 Voltage Offset Correction: v_off_ini = 153.680 uV, v_off_fin = 172.427 uV 19:36:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.347 uVs 19:36:33 I1Y Average and RMS of Measurements VT = -204.090 +- 2.492 uVs I1Y = -40.818 +- 0.498 uTm 19:36:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:36:38 Integrated Voltage Measurement... 19:36:47 Voltage Offset Correction: v_off_ini = 194.584 uV, v_off_fin = 184.647 uV 19:36:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.140 uVs 19:36:47 Integrated Voltage Measurement... 19:36:56 Voltage Offset Correction: v_off_ini = 199.946 uV, v_off_fin = 187.232 uV 19:36:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.644 uVs 19:36:56 Integrated Voltage Measurement... 19:37:05 Voltage Offset Correction: v_off_ini = 189.645 uV, v_off_fin = 162.917 uV 19:37:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -104.199 uVs 19:37:05 Integrated Voltage Measurement... 19:37:14 Voltage Offset Correction: v_off_ini = 175.873 uV, v_off_fin = 175.057 uV 19:37:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.793 uVs 19:37:14 Integrated Voltage Measurement... 19:37:23 Voltage Offset Correction: v_off_ini = 161.561 uV, v_off_fin = 159.511 uV 19:37:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.432 uVs 19:37:23 Integrated Voltage Measurement... 19:37:32 Voltage Offset Correction: v_off_ini = 170.680 uV, v_off_fin = 187.816 uV 19:37:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.525 uVs 19:37:34 I2X Average and RMS of Measurements VT = -94.122 +- 4.700 uVs I2X = 8.659 +- 0.432 uTm^2 19:37:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:37:39 Integrated Voltage Measurement... 19:37:48 Voltage Offset Correction: v_off_ini = 168.280 uV, v_off_fin = 166.329 uV 19:37:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.941 uVs 19:37:48 Integrated Voltage Measurement... 19:37:57 Voltage Offset Correction: v_off_ini = 165.057 uV, v_off_fin = 166.682 uV 19:37:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.729 uVs 19:37:58 Integrated Voltage Measurement... 19:38:06 Voltage Offset Correction: v_off_ini = 166.422 uV, v_off_fin = 168.405 uV 19:38:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.341 uVs 19:38:07 Integrated Voltage Measurement... 19:38:16 Voltage Offset Correction: v_off_ini = 152.904 uV, v_off_fin = 164.707 uV 19:38:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.188 uVs 19:38:16 Integrated Voltage Measurement... 19:38:25 Voltage Offset Correction: v_off_ini = 156.725 uV, v_off_fin = 167.377 uV 19:38:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.264 uVs 19:38:25 Integrated Voltage Measurement... 19:38:34 Voltage Offset Correction: v_off_ini = 156.571 uV, v_off_fin = 160.239 uV 19:38:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.749 uVs 19:38:36 I2Y Average and RMS of Measurements VT = -257.869 +- 5.884 uVs I2Y = -23.724 +- 0.541 uTm^2 19:38:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:38:44 Integrated Voltage Measurement... 19:38:53 Voltage Offset Correction: v_off_ini = 165.103 uV, v_off_fin = 158.658 uV 19:38:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -110.566 uVs 19:38:53 Integrated Voltage Measurement... 19:39:02 Voltage Offset Correction: v_off_ini = 173.230 uV, v_off_fin = 176.713 uV 19:39:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.808 uVs 19:39:02 Integrated Voltage Measurement... 19:39:11 Voltage Offset Correction: v_off_ini = 177.988 uV, v_off_fin = 167.364 uV 19:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.637 uVs 19:39:11 Integrated Voltage Measurement... 19:39:20 Voltage Offset Correction: v_off_ini = 165.285 uV, v_off_fin = 179.245 uV 19:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.322 uVs 19:39:20 Integrated Voltage Measurement... 19:39:29 Voltage Offset Correction: v_off_ini = 157.394 uV, v_off_fin = 163.920 uV 19:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.443 uVs 19:39:29 Integrated Voltage Measurement... 19:39:38 Voltage Offset Correction: v_off_ini = 173.246 uV, v_off_fin = 177.069 uV 19:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.274 uVs 19:39:43 I1X Average and RMS of Measurements VT = -102.175 +- 8.878 uVs I1X = 20.435 +- 1.776 uTm 19:39:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:39:49 Integrated Voltage Measurement... 19:39:58 Voltage Offset Correction: v_off_ini = 162.163 uV, v_off_fin = 164.874 uV 19:39:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -194.216 uVs 19:39:58 Integrated Voltage Measurement... 19:40:07 Voltage Offset Correction: v_off_ini = 185.554 uV, v_off_fin = 190.658 uV 19:40:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.470 uVs 19:40:07 Integrated Voltage Measurement... 19:40:16 Voltage Offset Correction: v_off_ini = 183.704 uV, v_off_fin = 173.766 uV 19:40:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.411 uVs 19:40:16 Integrated Voltage Measurement... 19:40:25 Voltage Offset Correction: v_off_ini = 190.187 uV, v_off_fin = 186.002 uV 19:40:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.890 uVs 19:40:25 Integrated Voltage Measurement... 19:40:34 Voltage Offset Correction: v_off_ini = 186.441 uV, v_off_fin = 177.456 uV 19:40:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.008 uVs 19:40:34 Integrated Voltage Measurement... 19:40:43 Voltage Offset Correction: v_off_ini = 192.295 uV, v_off_fin = 185.324 uV 19:40:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.862 uVs 19:40:48 I1Y Average and RMS of Measurements VT = -201.476 +- 6.067 uVs I1Y = -40.296 +- 1.214 uTm 19:40:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:40:53 Integrated Voltage Measurement... 19:41:02 Voltage Offset Correction: v_off_ini = 169.448 uV, v_off_fin = 170.854 uV 19:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.481 uVs 19:41:02 Integrated Voltage Measurement... 19:41:11 Voltage Offset Correction: v_off_ini = 184.209 uV, v_off_fin = 183.516 uV 19:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.750 uVs 19:41:11 Integrated Voltage Measurement... 19:41:20 Voltage Offset Correction: v_off_ini = 175.611 uV, v_off_fin = 175.902 uV 19:41:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.937 uVs 19:41:20 Integrated Voltage Measurement... 19:41:29 Voltage Offset Correction: v_off_ini = 180.980 uV, v_off_fin = 189.806 uV 19:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.015 uVs 19:41:29 Integrated Voltage Measurement... 19:41:38 Voltage Offset Correction: v_off_ini = 176.088 uV, v_off_fin = 163.568 uV 19:41:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.581 uVs 19:41:38 Integrated Voltage Measurement... 19:41:47 Voltage Offset Correction: v_off_ini = 181.809 uV, v_off_fin = 185.863 uV 19:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.953 uVs 19:41:49 I2X Average and RMS of Measurements VT = -99.120 +- 3.081 uVs I2X = 9.119 +- 0.283 uTm^2 19:41:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:41:54 Integrated Voltage Measurement... 19:42:03 Voltage Offset Correction: v_off_ini = 184.539 uV, v_off_fin = 196.134 uV 19:42:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.424 uVs 19:42:03 Integrated Voltage Measurement... 19:42:12 Voltage Offset Correction: v_off_ini = 188.564 uV, v_off_fin = 195.259 uV 19:42:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.554 uVs 19:42:13 Integrated Voltage Measurement... 19:42:22 Voltage Offset Correction: v_off_ini = 186.476 uV, v_off_fin = 183.073 uV 19:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.160 uVs 19:42:22 Integrated Voltage Measurement... 19:42:31 Voltage Offset Correction: v_off_ini = 187.782 uV, v_off_fin = 190.289 uV 19:42:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.347 uVs 19:42:31 Integrated Voltage Measurement... 19:42:40 Voltage Offset Correction: v_off_ini = 189.776 uV, v_off_fin = 188.471 uV 19:42:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.668 uVs 19:42:40 Integrated Voltage Measurement... 19:42:49 Voltage Offset Correction: v_off_ini = 193.557 uV, v_off_fin = 202.002 uV 19:42:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.717 uVs 19:42:51 I2Y Average and RMS of Measurements VT = -249.478 +- 4.413 uVs I2Y = -22.952 +- 0.406 uTm^2 19:42:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:42:59 Integrated Voltage Measurement... 19:43:08 Voltage Offset Correction: v_off_ini = 188.832 uV, v_off_fin = 184.346 uV 19:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.796 uVs 19:43:08 Integrated Voltage Measurement... 19:43:17 Voltage Offset Correction: v_off_ini = 180.505 uV, v_off_fin = 174.497 uV 19:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.834 uVs 19:43:17 Integrated Voltage Measurement... 19:43:26 Voltage Offset Correction: v_off_ini = 175.442 uV, v_off_fin = 182.576 uV 19:43:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.875 uVs 19:43:26 Integrated Voltage Measurement... 19:43:35 Voltage Offset Correction: v_off_ini = 196.917 uV, v_off_fin = 193.682 uV 19:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.712 uVs 19:43:35 Integrated Voltage Measurement... 19:43:44 Voltage Offset Correction: v_off_ini = 189.678 uV, v_off_fin = 185.191 uV 19:43:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.771 uVs 19:43:45 Integrated Voltage Measurement... 19:43:53 Voltage Offset Correction: v_off_ini = 195.485 uV, v_off_fin = 194.329 uV 19:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.435 uVs 19:43:58 I1X Average and RMS of Measurements VT = -92.404 +- 4.709 uVs I1X = 18.482 +- 0.942 uTm 19:44:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:44:04 Integrated Voltage Measurement... 19:44:13 Voltage Offset Correction: v_off_ini = 194.507 uV, v_off_fin = 185.222 uV 19:44:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.285 uVs 19:44:13 Integrated Voltage Measurement... 19:44:22 Voltage Offset Correction: v_off_ini = 177.989 uV, v_off_fin = 195.420 uV 19:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.113 uVs 19:44:22 Integrated Voltage Measurement... 19:44:31 Voltage Offset Correction: v_off_ini = 170.428 uV, v_off_fin = 156.383 uV 19:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.837 uVs 19:44:31 Integrated Voltage Measurement... 19:44:40 Voltage Offset Correction: v_off_ini = 162.854 uV, v_off_fin = 180.813 uV 19:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.482 uVs 19:44:40 Integrated Voltage Measurement... 19:44:49 Voltage Offset Correction: v_off_ini = 166.466 uV, v_off_fin = 156.272 uV 19:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.697 uVs 19:44:49 Integrated Voltage Measurement... 19:44:58 Voltage Offset Correction: v_off_ini = 173.150 uV, v_off_fin = 183.809 uV 19:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.100 uVs 19:45:03 I1Y Average and RMS of Measurements VT = -196.586 +- 3.862 uVs I1Y = -39.315 +- 0.771 uTm 19:45:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:45:08 Integrated Voltage Measurement... 19:45:17 Voltage Offset Correction: v_off_ini = 169.095 uV, v_off_fin = 164.175 uV 19:45:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.166 uVs 19:45:17 Integrated Voltage Measurement... 19:45:26 Voltage Offset Correction: v_off_ini = 170.397 uV, v_off_fin = 178.333 uV 19:45:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.272 uVs 19:45:26 Integrated Voltage Measurement... 19:45:35 Voltage Offset Correction: v_off_ini = 163.456 uV, v_off_fin = 159.063 uV 19:45:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.611 uVs 19:45:35 Integrated Voltage Measurement... 19:45:44 Voltage Offset Correction: v_off_ini = 155.865 uV, v_off_fin = 162.362 uV 19:45:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.344 uVs 19:45:44 Integrated Voltage Measurement... 19:45:53 Voltage Offset Correction: v_off_ini = 159.929 uV, v_off_fin = 150.294 uV 19:45:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.582 uVs 19:45:53 Integrated Voltage Measurement... 19:46:02 Voltage Offset Correction: v_off_ini = 161.428 uV, v_off_fin = 161.813 uV 19:46:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.917 uVs 19:46:04 I2X Average and RMS of Measurements VT = -104.649 +- 11.693 uVs I2X = 9.628 +- 1.076 uTm^2 19:46:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:46:09 Integrated Voltage Measurement... 19:46:18 Voltage Offset Correction: v_off_ini = 172.216 uV, v_off_fin = 163.282 uV 19:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.234 uVs 19:46:18 Integrated Voltage Measurement... 19:46:27 Voltage Offset Correction: v_off_ini = 184.759 uV, v_off_fin = 178.736 uV 19:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.090 uVs 19:46:27 Integrated Voltage Measurement... 19:46:36 Voltage Offset Correction: v_off_ini = 173.246 uV, v_off_fin = 189.255 uV 19:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.643 uVs 19:46:36 Integrated Voltage Measurement... 19:46:45 Voltage Offset Correction: v_off_ini = 178.013 uV, v_off_fin = 185.246 uV 19:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.538 uVs 19:46:46 Integrated Voltage Measurement... 19:46:54 Voltage Offset Correction: v_off_ini = 176.380 uV, v_off_fin = 181.381 uV 19:46:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.948 uVs 19:46:55 Integrated Voltage Measurement... 19:47:03 Voltage Offset Correction: v_off_ini = 168.338 uV, v_off_fin = 178.012 uV 19:47:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.490 uVs 19:47:06 I2Y Average and RMS of Measurements VT = -256.157 +- 5.002 uVs I2Y = -23.566 +- 0.460 uTm^2 19:47:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:47:14 Integrated Voltage Measurement... 19:47:23 Voltage Offset Correction: v_off_ini = 177.247 uV, v_off_fin = 162.484 uV 19:47:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -87.225 uVs 19:47:23 Integrated Voltage Measurement... 19:47:32 Voltage Offset Correction: v_off_ini = 165.181 uV, v_off_fin = 158.452 uV 19:47:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.938 uVs 19:47:32 Integrated Voltage Measurement... 19:47:41 Voltage Offset Correction: v_off_ini = 157.992 uV, v_off_fin = 166.612 uV 19:47:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.702 uVs 19:47:41 Integrated Voltage Measurement... 19:47:50 Voltage Offset Correction: v_off_ini = 184.616 uV, v_off_fin = 173.675 uV 19:47:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.229 uVs 19:47:50 Integrated Voltage Measurement... 19:47:59 Voltage Offset Correction: v_off_ini = 167.261 uV, v_off_fin = 171.319 uV 19:47:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.777 uVs 19:47:59 Integrated Voltage Measurement... 19:48:08 Voltage Offset Correction: v_off_ini = 175.203 uV, v_off_fin = 178.129 uV 19:48:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.511 uVs 19:48:13 I1X Average and RMS of Measurements VT = -89.730 +- 5.447 uVs I1X = 17.947 +- 1.090 uTm 19:48:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:48:19 Integrated Voltage Measurement... 19:48:28 Voltage Offset Correction: v_off_ini = 178.706 uV, v_off_fin = 174.017 uV 19:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.497 uVs 19:48:28 Integrated Voltage Measurement... 19:48:37 Voltage Offset Correction: v_off_ini = 175.271 uV, v_off_fin = 194.997 uV 19:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.510 uVs 19:48:37 Integrated Voltage Measurement... 19:48:46 Voltage Offset Correction: v_off_ini = 191.650 uV, v_off_fin = 168.032 uV 19:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.777 uVs 19:48:46 Integrated Voltage Measurement... 19:48:55 Voltage Offset Correction: v_off_ini = 186.560 uV, v_off_fin = 182.583 uV 19:48:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.178 uVs 19:48:55 Integrated Voltage Measurement... 19:49:04 Voltage Offset Correction: v_off_ini = 176.807 uV, v_off_fin = 166.572 uV 19:49:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.023 uVs 19:49:04 Integrated Voltage Measurement... 19:49:13 Voltage Offset Correction: v_off_ini = 165.255 uV, v_off_fin = 184.577 uV 19:49:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.837 uVs 19:49:18 I1Y Average and RMS of Measurements VT = -205.471 +- 6.370 uVs I1Y = -41.092 +- 1.272 uTm 19:49:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:49:23 Integrated Voltage Measurement... 19:49:32 Voltage Offset Correction: v_off_ini = 173.319 uV, v_off_fin = 158.574 uV 19:49:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.957 uVs 19:49:32 Integrated Voltage Measurement... 19:49:41 Voltage Offset Correction: v_off_ini = 178.267 uV, v_off_fin = 167.452 uV 19:49:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.054 uVs 19:49:41 Integrated Voltage Measurement... 19:49:50 Voltage Offset Correction: v_off_ini = 185.790 uV, v_off_fin = 163.863 uV 19:49:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.812 uVs 19:49:50 Integrated Voltage Measurement... 19:49:59 Voltage Offset Correction: v_off_ini = 172.586 uV, v_off_fin = 171.268 uV 19:49:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.723 uVs 19:49:59 Integrated Voltage Measurement... 19:50:08 Voltage Offset Correction: v_off_ini = 169.329 uV, v_off_fin = 158.095 uV 19:50:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.798 uVs 19:50:08 Integrated Voltage Measurement... 19:50:17 Voltage Offset Correction: v_off_ini = 141.914 uV, v_off_fin = 152.761 uV 19:50:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.039 uVs 19:50:19 I2X Average and RMS of Measurements VT = -99.731 +- 5.716 uVs I2X = 9.175 +- 0.526 uTm^2 19:50:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:50:24 Integrated Voltage Measurement... 19:50:33 Voltage Offset Correction: v_off_ini = 163.567 uV, v_off_fin = 177.893 uV 19:50:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.687 uVs 19:50:33 Integrated Voltage Measurement... 19:50:42 Voltage Offset Correction: v_off_ini = 181.001 uV, v_off_fin = 174.630 uV 19:50:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.775 uVs 19:50:42 Integrated Voltage Measurement... 19:50:51 Voltage Offset Correction: v_off_ini = 167.617 uV, v_off_fin = 162.651 uV 19:50:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.180 uVs 19:50:51 Integrated Voltage Measurement... 19:51:00 Voltage Offset Correction: v_off_ini = 145.166 uV, v_off_fin = 165.169 uV 19:51:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.749 uVs 19:51:01 Integrated Voltage Measurement... 19:51:09 Voltage Offset Correction: v_off_ini = 164.662 uV, v_off_fin = 151.995 uV 19:51:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.004 uVs 19:51:10 Integrated Voltage Measurement... 19:51:18 Voltage Offset Correction: v_off_ini = 174.596 uV, v_off_fin = 160.043 uV 19:51:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.299 uVs 19:51:21 I2Y Average and RMS of Measurements VT = -253.116 +- 11.962 uVs I2Y = -23.287 +- 1.101 uTm^2 19:51:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:38:46 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm