SLAC Magnetic Measurements Date: 07-24-2025 Time: 14:52:40 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16341 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 4 Measurement Device: Operator: YL Comment: 14:52:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:52 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:52:54 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:52:55 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:52:57 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:53:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:12 Integrated Voltage Measurement... 14:53:21 Voltage Offset Correction: v_off_ini = 385.845 uV, v_off_fin = 365.287 uV 14:53:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.252 uVs 14:53:21 Integrated Voltage Measurement... 14:53:30 Voltage Offset Correction: v_off_ini = 362.313 uV, v_off_fin = 376.060 uV 14:53:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.505 uVs 14:53:30 Integrated Voltage Measurement... 14:53:39 Voltage Offset Correction: v_off_ini = 372.222 uV, v_off_fin = 385.005 uV 14:53:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.040 uVs 14:53:39 Integrated Voltage Measurement... 14:53:48 Voltage Offset Correction: v_off_ini = 393.099 uV, v_off_fin = 390.844 uV 14:53:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.651 uVs 14:53:48 Integrated Voltage Measurement... 14:53:57 Voltage Offset Correction: v_off_ini = 407.359 uV, v_off_fin = 393.397 uV 14:53:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.468 uVs 14:53:57 Integrated Voltage Measurement... 14:54:06 Voltage Offset Correction: v_off_ini = 413.811 uV, v_off_fin = 408.701 uV 14:54:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.534 uVs 14:54:10 I1X Average and RMS of Measurements VT = -65.075 +- 7.268 uVs I1X = 13.015 +- 1.454 uTm 14:54:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:17 Integrated Voltage Measurement... 14:54:26 Voltage Offset Correction: v_off_ini = 415.500 uV, v_off_fin = 400.855 uV 14:54:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.304 uVs 14:54:26 Integrated Voltage Measurement... 14:54:35 Voltage Offset Correction: v_off_ini = 397.576 uV, v_off_fin = 413.734 uV 14:54:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 266.421 uVs 14:54:35 Integrated Voltage Measurement... 14:54:44 Voltage Offset Correction: v_off_ini = 401.443 uV, v_off_fin = 388.913 uV 14:54:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -266.220 uVs 14:54:44 Integrated Voltage Measurement... 14:54:53 Voltage Offset Correction: v_off_ini = 399.486 uV, v_off_fin = 420.728 uV 14:54:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 262.243 uVs 14:54:53 Integrated Voltage Measurement... 14:55:02 Voltage Offset Correction: v_off_ini = 408.592 uV, v_off_fin = 417.047 uV 14:55:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -263.490 uVs 14:55:02 Integrated Voltage Measurement... 14:55:11 Voltage Offset Correction: v_off_ini = 428.913 uV, v_off_fin = 440.827 uV 14:55:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 261.146 uVs 14:55:15 I1Y Average and RMS of Measurements VT = -262.971 +- 0.892 uVs I1Y = -52.590 +- 0.178 uTm 14:55:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:23 Integrated Voltage Measurement... 14:55:32 Voltage Offset Correction: v_off_ini = 420.452 uV, v_off_fin = 418.688 uV 14:55:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -71.878 uVs 14:55:32 Integrated Voltage Measurement... 14:55:41 Voltage Offset Correction: v_off_ini = 441.856 uV, v_off_fin = 454.486 uV 14:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.115 uVs 14:55:41 Integrated Voltage Measurement... 14:55:50 Voltage Offset Correction: v_off_ini = 459.014 uV, v_off_fin = 437.827 uV 14:55:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.193 uVs 14:55:50 Integrated Voltage Measurement... 14:55:59 Voltage Offset Correction: v_off_ini = 447.411 uV, v_off_fin = 457.429 uV 14:55:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.237 uVs 14:55:59 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = 455.761 uV, v_off_fin = 446.600 uV 14:56:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.818 uVs 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = 467.372 uV, v_off_fin = 466.638 uV 14:56:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.021 uVs 14:56:19 I2X Average and RMS of Measurements VT = -67.544 +- 2.443 uVs I2X = 6.214 +- 0.225 uTm^2 14:56:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:27 Integrated Voltage Measurement... 14:56:36 Voltage Offset Correction: v_off_ini = 471.771 uV, v_off_fin = 476.317 uV 14:56:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -526.614 uVs 14:56:36 Integrated Voltage Measurement... 14:56:45 Voltage Offset Correction: v_off_ini = 482.681 uV, v_off_fin = 479.510 uV 14:56:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 516.275 uVs 14:56:45 Integrated Voltage Measurement... 14:56:54 Voltage Offset Correction: v_off_ini = 477.427 uV, v_off_fin = 475.713 uV 14:56:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.769 uVs 14:56:54 Integrated Voltage Measurement... 14:57:03 Voltage Offset Correction: v_off_ini = 475.426 uV, v_off_fin = 490.990 uV 14:57:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 522.490 uVs 14:57:03 Integrated Voltage Measurement... 14:57:12 Voltage Offset Correction: v_off_ini = 487.733 uV, v_off_fin = 495.612 uV 14:57:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -515.036 uVs 14:57:12 Integrated Voltage Measurement... 14:57:21 Voltage Offset Correction: v_off_ini = 497.880 uV, v_off_fin = 496.711 uV 14:57:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 528.264 uVs 14:57:24 I2Y Average and RMS of Measurements VT = -520.408 +- 1.613 uVs I2Y = -47.878 +- 0.148 uTm^2 14:57:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:39 Integrated Voltage Measurement... 14:57:47 Voltage Offset Correction: v_off_ini = 506.013 uV, v_off_fin = 497.919 uV 14:57:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -69.707 uVs 14:57:48 Integrated Voltage Measurement... 14:57:56 Voltage Offset Correction: v_off_ini = 498.095 uV, v_off_fin = 487.938 uV 14:57:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.223 uVs 14:57:57 Integrated Voltage Measurement... 14:58:05 Voltage Offset Correction: v_off_ini = 493.233 uV, v_off_fin = 489.885 uV 14:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.486 uVs 14:58:05 Integrated Voltage Measurement... 14:58:14 Voltage Offset Correction: v_off_ini = 500.485 uV, v_off_fin = 493.217 uV 14:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.692 uVs 14:58:14 Integrated Voltage Measurement... 14:58:23 Voltage Offset Correction: v_off_ini = 494.602 uV, v_off_fin = 478.755 uV 14:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.169 uVs 14:58:23 Integrated Voltage Measurement... 14:58:32 Voltage Offset Correction: v_off_ini = 482.136 uV, v_off_fin = 500.127 uV 14:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.129 uVs 14:58:37 I1X Average and RMS of Measurements VT = -74.568 +- 1.558 uVs I1X = 14.914 +- 0.312 uTm 14:58:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:43 Integrated Voltage Measurement... 14:58:52 Voltage Offset Correction: v_off_ini = 485.912 uV, v_off_fin = 479.439 uV 14:58:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -234.244 uVs 14:58:52 Integrated Voltage Measurement... 14:59:01 Voltage Offset Correction: v_off_ini = 498.888 uV, v_off_fin = 504.298 uV 14:59:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.301 uVs 14:59:01 Integrated Voltage Measurement... 14:59:10 Voltage Offset Correction: v_off_ini = 494.456 uV, v_off_fin = 486.769 uV 14:59:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -253.365 uVs 14:59:10 Integrated Voltage Measurement... 14:59:19 Voltage Offset Correction: v_off_ini = 488.986 uV, v_off_fin = 519.822 uV 14:59:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.251 uVs 14:59:19 Integrated Voltage Measurement... 14:59:28 Voltage Offset Correction: v_off_ini = 500.873 uV, v_off_fin = 475.983 uV 14:59:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.712 uVs 14:59:28 Integrated Voltage Measurement... 14:59:37 Voltage Offset Correction: v_off_ini = 493.541 uV, v_off_fin = 514.201 uV 14:59:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 249.437 uVs 14:59:41 I1Y Average and RMS of Measurements VT = -243.885 +- 3.518 uVs I1Y = -48.775 +- 0.701 uTm 14:59:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:49 Integrated Voltage Measurement... 14:59:58 Voltage Offset Correction: v_off_ini = 488.592 uV, v_off_fin = 503.168 uV 14:59:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.311 uVs 14:59:58 Integrated Voltage Measurement... 15:00:07 Voltage Offset Correction: v_off_ini = 511.961 uV, v_off_fin = 516.067 uV 15:00:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.143 uVs 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 507.097 uV, v_off_fin = 509.156 uV 15:00:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.000 uVs 15:00:16 Integrated Voltage Measurement... 15:00:25 Voltage Offset Correction: v_off_ini = 523.277 uV, v_off_fin = 524.360 uV 15:00:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.092 uVs 15:00:25 Integrated Voltage Measurement... 15:00:34 Voltage Offset Correction: v_off_ini = 522.634 uV, v_off_fin = 502.693 uV 15:00:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.195 uVs 15:00:34 Integrated Voltage Measurement... 15:00:43 Voltage Offset Correction: v_off_ini = 512.144 uV, v_off_fin = 513.577 uV 15:00:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.252 uVs 15:00:46 I2X Average and RMS of Measurements VT = -84.499 +- 4.929 uVs I2X = 7.774 +- 0.453 uTm^2 15:00:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:53 Integrated Voltage Measurement... 15:01:02 Voltage Offset Correction: v_off_ini = 510.753 uV, v_off_fin = 521.783 uV 15:01:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -494.011 uVs 15:01:02 Integrated Voltage Measurement... 15:01:11 Voltage Offset Correction: v_off_ini = 520.001 uV, v_off_fin = 530.135 uV 15:01:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.338 uVs 15:01:11 Integrated Voltage Measurement... 15:01:20 Voltage Offset Correction: v_off_ini = 510.823 uV, v_off_fin = 517.487 uV 15:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -513.416 uVs 15:01:20 Integrated Voltage Measurement... 15:01:29 Voltage Offset Correction: v_off_ini = 521.281 uV, v_off_fin = 523.620 uV 15:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 499.278 uVs 15:01:29 Integrated Voltage Measurement... 15:01:38 Voltage Offset Correction: v_off_ini = 535.554 uV, v_off_fin = 522.522 uV 15:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -501.550 uVs 15:01:38 Integrated Voltage Measurement... 15:01:47 Voltage Offset Correction: v_off_ini = 537.366 uV, v_off_fin = 502.619 uV 15:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 482.021 uVs 15:01:50 I2Y Average and RMS of Measurements VT = -498.269 +- 6.050 uVs I2Y = -45.841 +- 0.556 uTm^2 15:02:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:05 Integrated Voltage Measurement... 15:02:14 Voltage Offset Correction: v_off_ini = 551.059 uV, v_off_fin = 545.480 uV 15:02:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.530 uVs 15:02:14 Integrated Voltage Measurement... 15:02:23 Voltage Offset Correction: v_off_ini = 540.915 uV, v_off_fin = 544.136 uV 15:02:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.250 uVs 15:02:23 Integrated Voltage Measurement... 15:02:32 Voltage Offset Correction: v_off_ini = 529.279 uV, v_off_fin = 530.274 uV 15:02:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -47.760 uVs 15:02:32 Integrated Voltage Measurement... 15:02:41 Voltage Offset Correction: v_off_ini = 546.266 uV, v_off_fin = 542.444 uV 15:02:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.544 uVs 15:02:41 Integrated Voltage Measurement... 15:02:50 Voltage Offset Correction: v_off_ini = 547.852 uV, v_off_fin = 536.341 uV 15:02:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.885 uVs 15:02:50 Integrated Voltage Measurement... 15:02:59 Voltage Offset Correction: v_off_ini = 551.880 uV, v_off_fin = 559.358 uV 15:02:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.093 uVs 15:03:03 I1X Average and RMS of Measurements VT = -72.177 +- 5.406 uVs I1X = 14.437 +- 1.081 uTm 15:03:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:10 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 539.186 uV, v_off_fin = 533.545 uV 15:03:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.487 uVs 15:03:19 Integrated Voltage Measurement... 15:03:28 Voltage Offset Correction: v_off_ini = 563.512 uV, v_off_fin = 580.429 uV 15:03:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.644 uVs 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 567.025 uV, v_off_fin = 543.482 uV 15:03:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.333 uVs 15:03:37 Integrated Voltage Measurement... 15:03:46 Voltage Offset Correction: v_off_ini = 552.405 uV, v_off_fin = 564.828 uV 15:03:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 245.656 uVs 15:03:46 Integrated Voltage Measurement... 15:03:55 Voltage Offset Correction: v_off_ini = 562.371 uV, v_off_fin = 538.834 uV 15:03:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.298 uVs 15:03:55 Integrated Voltage Measurement... 15:04:03 Voltage Offset Correction: v_off_ini = 553.124 uV, v_off_fin = 566.129 uV 15:04:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.449 uVs 15:04:08 I1Y Average and RMS of Measurements VT = -239.145 +- 4.675 uVs I1Y = -47.826 +- 0.935 uTm 15:04:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 547.909 uV, v_off_fin = 555.874 uV 15:04:24 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.554 uVs 15:04:24 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 563.783 uV, v_off_fin = 563.038 uV 15:04:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.694 uVs 15:04:33 Integrated Voltage Measurement... 15:04:42 Voltage Offset Correction: v_off_ini = 565.045 uV, v_off_fin = 562.708 uV 15:04:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.587 uVs 15:04:42 Integrated Voltage Measurement... 15:04:51 Voltage Offset Correction: v_off_ini = 567.102 uV, v_off_fin = 570.662 uV 15:04:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.451 uVs 15:04:51 Integrated Voltage Measurement... 15:05:00 Voltage Offset Correction: v_off_ini = 554.047 uV, v_off_fin = 552.880 uV 15:05:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.045 uVs 15:05:01 Integrated Voltage Measurement... 15:05:09 Voltage Offset Correction: v_off_ini = 560.838 uV, v_off_fin = 573.425 uV 15:05:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.541 uVs 15:05:12 I2X Average and RMS of Measurements VT = -85.645 +- 4.154 uVs I2X = 7.879 +- 0.382 uTm^2 15:05:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:20 Integrated Voltage Measurement... 15:05:29 Voltage Offset Correction: v_off_ini = 561.359 uV, v_off_fin = 570.230 uV 15:05:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -462.741 uVs 15:05:29 Integrated Voltage Measurement... 15:05:38 Voltage Offset Correction: v_off_ini = 548.013 uV, v_off_fin = 549.640 uV 15:05:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 490.357 uVs 15:05:38 Integrated Voltage Measurement... 15:05:47 Voltage Offset Correction: v_off_ini = 538.224 uV, v_off_fin = 534.647 uV 15:05:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -461.836 uVs 15:05:47 Integrated Voltage Measurement... 15:05:56 Voltage Offset Correction: v_off_ini = 545.298 uV, v_off_fin = 541.028 uV 15:05:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 491.387 uVs 15:05:56 Integrated Voltage Measurement... 15:06:05 Voltage Offset Correction: v_off_ini = 542.129 uV, v_off_fin = 543.343 uV 15:06:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -474.823 uVs 15:06:05 Integrated Voltage Measurement... 15:06:14 Voltage Offset Correction: v_off_ini = 548.855 uV, v_off_fin = 551.763 uV 15:06:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 498.299 uVs 15:06:16 I2Y Average and RMS of Measurements VT = -479.907 +- 4.705 uVs I2Y = -44.151 +- 0.433 uTm^2 15:06:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:31 Integrated Voltage Measurement... 15:06:40 Voltage Offset Correction: v_off_ini = 555.122 uV, v_off_fin = 549.568 uV 15:06:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.169 uVs 15:06:40 Integrated Voltage Measurement... 15:06:49 Voltage Offset Correction: v_off_ini = 557.919 uV, v_off_fin = 546.284 uV 15:06:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.574 uVs 15:06:49 Integrated Voltage Measurement... 15:06:58 Voltage Offset Correction: v_off_ini = 552.596 uV, v_off_fin = 558.906 uV 15:06:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.945 uVs 15:06:58 Integrated Voltage Measurement... 15:07:07 Voltage Offset Correction: v_off_ini = 553.449 uV, v_off_fin = 567.754 uV 15:07:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.662 uVs 15:07:07 Integrated Voltage Measurement... 15:07:16 Voltage Offset Correction: v_off_ini = 555.312 uV, v_off_fin = 550.230 uV 15:07:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.221 uVs 15:07:16 Integrated Voltage Measurement... 15:07:25 Voltage Offset Correction: v_off_ini = 561.920 uV, v_off_fin = 556.946 uV 15:07:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.161 uVs 15:07:29 I1X Average and RMS of Measurements VT = -78.455 +- 2.724 uVs I1X = 15.691 +- 0.545 uTm 15:07:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:36 Integrated Voltage Measurement... 15:07:45 Voltage Offset Correction: v_off_ini = 564.300 uV, v_off_fin = 552.339 uV 15:07:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.498 uVs 15:07:45 Integrated Voltage Measurement... 15:07:54 Voltage Offset Correction: v_off_ini = 559.436 uV, v_off_fin = 577.299 uV 15:07:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.654 uVs 15:07:54 Integrated Voltage Measurement... 15:08:03 Voltage Offset Correction: v_off_ini = 570.165 uV, v_off_fin = 556.145 uV 15:08:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.240 uVs 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 572.418 uV, v_off_fin = 573.624 uV 15:08:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.533 uVs 15:08:12 Integrated Voltage Measurement... 15:08:21 Voltage Offset Correction: v_off_ini = 552.008 uV, v_off_fin = 542.299 uV 15:08:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.760 uVs 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 555.744 uV, v_off_fin = 556.212 uV 15:08:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 223.671 uVs 15:08:34 I1Y Average and RMS of Measurements VT = -222.392 +- 4.141 uVs I1Y = -44.474 +- 0.827 uTm 15:08:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:42 Integrated Voltage Measurement... 15:08:51 Voltage Offset Correction: v_off_ini = 548.705 uV, v_off_fin = 540.299 uV 15:08:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -81.301 uVs 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = 544.963 uV, v_off_fin = 567.443 uV 15:09:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.191 uVs 15:09:00 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = 556.234 uV, v_off_fin = 547.083 uV 15:09:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.896 uVs 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 545.105 uV, v_off_fin = 556.283 uV 15:09:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.725 uVs 15:09:18 Integrated Voltage Measurement... 15:09:27 Voltage Offset Correction: v_off_ini = 557.584 uV, v_off_fin = 544.713 uV 15:09:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.000 uVs 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = 547.457 uV, v_off_fin = 555.993 uV 15:09:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.064 uVs 15:09:38 I2X Average and RMS of Measurements VT = -91.196 +- 4.815 uVs I2X = 8.390 +- 0.443 uTm^2 15:09:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:46 Integrated Voltage Measurement... 15:09:55 Voltage Offset Correction: v_off_ini = 564.237 uV, v_off_fin = 553.644 uV 15:09:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -470.463 uVs 15:09:55 Integrated Voltage Measurement... 15:10:04 Voltage Offset Correction: v_off_ini = 557.833 uV, v_off_fin = 543.948 uV 15:10:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 460.190 uVs 15:10:04 Integrated Voltage Measurement... 15:10:13 Voltage Offset Correction: v_off_ini = 546.785 uV, v_off_fin = 545.972 uV 15:10:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -471.826 uVs 15:10:13 Integrated Voltage Measurement... 15:10:22 Voltage Offset Correction: v_off_ini = 543.615 uV, v_off_fin = 543.196 uV 15:10:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 455.193 uVs 15:10:22 Integrated Voltage Measurement... 15:10:31 Voltage Offset Correction: v_off_ini = 537.867 uV, v_off_fin = 552.862 uV 15:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -458.427 uVs 15:10:31 Integrated Voltage Measurement... 15:10:40 Voltage Offset Correction: v_off_ini = 545.105 uV, v_off_fin = 549.413 uV 15:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 470.585 uVs 15:10:42 I2Y Average and RMS of Measurements VT = -464.447 +- 0.743 uVs I2Y = -42.730 +- 0.069 uTm^2 15:10:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:57 Integrated Voltage Measurement... 15:11:06 Voltage Offset Correction: v_off_ini = 534.290 uV, v_off_fin = 546.793 uV 15:11:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.517 uVs 15:11:06 Integrated Voltage Measurement... 15:11:15 Voltage Offset Correction: v_off_ini = 543.918 uV, v_off_fin = 541.279 uV 15:11:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.582 uVs 15:11:15 Integrated Voltage Measurement... 15:11:24 Voltage Offset Correction: v_off_ini = 542.476 uV, v_off_fin = 537.588 uV 15:11:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.414 uVs 15:11:24 Integrated Voltage Measurement... 15:11:33 Voltage Offset Correction: v_off_ini = 530.499 uV, v_off_fin = 547.626 uV 15:11:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.430 uVs 15:11:33 Integrated Voltage Measurement... 15:11:42 Voltage Offset Correction: v_off_ini = 551.719 uV, v_off_fin = 541.998 uV 15:11:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.371 uVs 15:11:42 Integrated Voltage Measurement... 15:11:51 Voltage Offset Correction: v_off_ini = 549.104 uV, v_off_fin = 559.511 uV 15:11:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.354 uVs 15:11:56 I1X Average and RMS of Measurements VT = -70.111 +- 4.489 uVs I1X = 14.022 +- 0.898 uTm 15:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:02 Integrated Voltage Measurement... 15:12:11 Voltage Offset Correction: v_off_ini = 537.660 uV, v_off_fin = 546.607 uV 15:12:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.072 uVs 15:12:11 Integrated Voltage Measurement... 15:12:20 Voltage Offset Correction: v_off_ini = 547.236 uV, v_off_fin = 564.846 uV 15:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 221.794 uVs 15:12:20 Integrated Voltage Measurement... 15:12:29 Voltage Offset Correction: v_off_ini = 553.400 uV, v_off_fin = 521.041 uV 15:12:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -218.962 uVs 15:12:29 Integrated Voltage Measurement... 15:12:38 Voltage Offset Correction: v_off_ini = 548.083 uV, v_off_fin = 540.957 uV 15:12:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.823 uVs 15:12:38 Integrated Voltage Measurement... 15:12:47 Voltage Offset Correction: v_off_ini = 566.984 uV, v_off_fin = 548.214 uV 15:12:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.663 uVs 15:12:47 Integrated Voltage Measurement... 15:12:56 Voltage Offset Correction: v_off_ini = 550.279 uV, v_off_fin = 565.327 uV 15:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.397 uVs 15:13:00 I1Y Average and RMS of Measurements VT = -217.785 +- 8.303 uVs I1Y = -43.552 +- 1.660 uTm 15:13:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:08 Integrated Voltage Measurement... 15:13:17 Voltage Offset Correction: v_off_ini = 550.687 uV, v_off_fin = 526.924 uV 15:13:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -103.693 uVs 15:13:17 Integrated Voltage Measurement... 15:13:26 Voltage Offset Correction: v_off_ini = 544.028 uV, v_off_fin = 556.057 uV 15:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.565 uVs 15:13:26 Integrated Voltage Measurement... 15:13:35 Voltage Offset Correction: v_off_ini = 571.386 uV, v_off_fin = 563.234 uV 15:13:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.511 uVs 15:13:35 Integrated Voltage Measurement... 15:13:44 Voltage Offset Correction: v_off_ini = 571.565 uV, v_off_fin = 553.101 uV 15:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.238 uVs 15:13:44 Integrated Voltage Measurement... 15:13:53 Voltage Offset Correction: v_off_ini = 537.179 uV, v_off_fin = 530.762 uV 15:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.558 uVs 15:13:53 Integrated Voltage Measurement... 15:14:02 Voltage Offset Correction: v_off_ini = 533.507 uV, v_off_fin = 546.403 uV 15:14:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.615 uVs 15:14:05 I2X Average and RMS of Measurements VT = -88.697 +- 3.502 uVs I2X = 8.160 +- 0.322 uTm^2 15:14:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:12 Integrated Voltage Measurement... 15:14:21 Voltage Offset Correction: v_off_ini = 545.412 uV, v_off_fin = 530.975 uV 15:14:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -436.374 uVs 15:14:21 Integrated Voltage Measurement... 15:14:30 Voltage Offset Correction: v_off_ini = 535.322 uV, v_off_fin = 542.885 uV 15:14:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.735 uVs 15:14:30 Integrated Voltage Measurement... 15:14:39 Voltage Offset Correction: v_off_ini = 555.303 uV, v_off_fin = 552.107 uV 15:14:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -433.196 uVs 15:14:39 Integrated Voltage Measurement... 15:14:48 Voltage Offset Correction: v_off_ini = 547.718 uV, v_off_fin = 544.370 uV 15:14:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 441.959 uVs 15:14:48 Integrated Voltage Measurement... 15:14:57 Voltage Offset Correction: v_off_ini = 540.696 uV, v_off_fin = 546.689 uV 15:14:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -428.693 uVs 15:14:57 Integrated Voltage Measurement... 15:15:06 Voltage Offset Correction: v_off_ini = 541.947 uV, v_off_fin = 559.833 uV 15:15:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.684 uVs 15:15:09 I2Y Average and RMS of Measurements VT = -436.107 +- 3.963 uVs I2Y = -40.122 +- 0.365 uTm^2 15:15:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:24 Integrated Voltage Measurement... 15:15:33 Voltage Offset Correction: v_off_ini = 543.872 uV, v_off_fin = 554.504 uV 15:15:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -46.859 uVs 15:15:33 Integrated Voltage Measurement... 15:15:42 Voltage Offset Correction: v_off_ini = 563.625 uV, v_off_fin = 551.843 uV 15:15:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.545 uVs 15:15:42 Integrated Voltage Measurement... 15:15:51 Voltage Offset Correction: v_off_ini = 545.719 uV, v_off_fin = 550.589 uV 15:15:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -67.246 uVs 15:15:51 Integrated Voltage Measurement... 15:16:00 Voltage Offset Correction: v_off_ini = 564.860 uV, v_off_fin = 563.882 uV 15:16:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 68.875 uVs 15:16:00 Integrated Voltage Measurement... 15:16:09 Voltage Offset Correction: v_off_ini = 574.406 uV, v_off_fin = 572.170 uV 15:16:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -83.788 uVs 15:16:09 Integrated Voltage Measurement... 15:16:18 Voltage Offset Correction: v_off_ini = 569.224 uV, v_off_fin = 559.519 uV 15:16:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.549 uVs 15:16:22 I1X Average and RMS of Measurements VT = -71.310 +- 6.719 uVs I1X = 14.264 +- 1.345 uTm 15:16:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:29 Integrated Voltage Measurement... 15:16:38 Voltage Offset Correction: v_off_ini = 569.003 uV, v_off_fin = 547.895 uV 15:16:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -202.058 uVs 15:16:38 Integrated Voltage Measurement... 15:16:47 Voltage Offset Correction: v_off_ini = 578.809 uV, v_off_fin = 572.029 uV 15:16:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.607 uVs 15:16:47 Integrated Voltage Measurement... 15:16:56 Voltage Offset Correction: v_off_ini = 576.333 uV, v_off_fin = 570.168 uV 15:16:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.132 uVs 15:16:56 Integrated Voltage Measurement... 15:17:05 Voltage Offset Correction: v_off_ini = 570.403 uV, v_off_fin = 590.841 uV 15:17:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.532 uVs 15:17:05 Integrated Voltage Measurement... 15:17:14 Voltage Offset Correction: v_off_ini = 586.963 uV, v_off_fin = 570.367 uV 15:17:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.074 uVs 15:17:14 Integrated Voltage Measurement... 15:17:23 Voltage Offset Correction: v_off_ini = 580.714 uV, v_off_fin = 607.243 uV 15:17:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.033 uVs 15:17:27 I1Y Average and RMS of Measurements VT = -208.239 +- 5.445 uVs I1Y = -41.647 +- 1.086 uTm 15:17:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:35 Integrated Voltage Measurement... 15:17:44 Voltage Offset Correction: v_off_ini = 591.063 uV, v_off_fin = 589.602 uV 15:17:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -83.666 uVs 15:17:44 Integrated Voltage Measurement... 15:17:53 Voltage Offset Correction: v_off_ini = 602.587 uV, v_off_fin = 621.939 uV 15:17:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.102 uVs 15:17:53 Integrated Voltage Measurement... 15:18:02 Voltage Offset Correction: v_off_ini = 614.300 uV, v_off_fin = 598.079 uV 15:18:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.077 uVs 15:18:02 Integrated Voltage Measurement... 15:18:11 Voltage Offset Correction: v_off_ini = 617.589 uV, v_off_fin = 607.279 uV 15:18:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.536 uVs 15:18:11 Integrated Voltage Measurement... 15:18:20 Voltage Offset Correction: v_off_ini = 597.805 uV, v_off_fin = 599.013 uV 15:18:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.747 uVs 15:18:20 Integrated Voltage Measurement... 15:18:29 Voltage Offset Correction: v_off_ini = 610.805 uV, v_off_fin = 611.682 uV 15:18:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.387 uVs 15:18:31 I2X Average and RMS of Measurements VT = -83.419 +- 4.193 uVs I2X = 7.674 +- 0.386 uTm^2 15:18:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:39 Integrated Voltage Measurement... 15:18:48 Voltage Offset Correction: v_off_ini = 616.040 uV, v_off_fin = 615.661 uV 15:18:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -418.439 uVs 15:18:48 Integrated Voltage Measurement... 15:18:57 Voltage Offset Correction: v_off_ini = 611.879 uV, v_off_fin = 612.790 uV 15:18:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 426.138 uVs 15:18:57 Integrated Voltage Measurement... 15:19:06 Voltage Offset Correction: v_off_ini = 608.159 uV, v_off_fin = 601.981 uV 15:19:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -411.847 uVs 15:19:06 Integrated Voltage Measurement... 15:19:15 Voltage Offset Correction: v_off_ini = 602.743 uV, v_off_fin = 605.037 uV 15:19:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.239 uVs 15:19:15 Integrated Voltage Measurement... 15:19:24 Voltage Offset Correction: v_off_ini = 608.895 uV, v_off_fin = 602.820 uV 15:19:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -447.145 uVs 15:19:24 Integrated Voltage Measurement... 15:19:33 Voltage Offset Correction: v_off_ini = 594.981 uV, v_off_fin = 593.294 uV 15:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 437.160 uVs 15:19:35 I2Y Average and RMS of Measurements VT = -429.995 +- 8.699 uVs I2Y = -39.560 +- 0.800 uTm^2 15:19:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:50 Integrated Voltage Measurement... 15:19:59 Voltage Offset Correction: v_off_ini = 607.007 uV, v_off_fin = 592.068 uV 15:19:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -87.582 uVs 15:19:59 Integrated Voltage Measurement... 15:20:08 Voltage Offset Correction: v_off_ini = 583.129 uV, v_off_fin = 591.837 uV 15:20:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.651 uVs 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = 589.914 uV, v_off_fin = 603.937 uV 15:20:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.455 uVs 15:20:17 Integrated Voltage Measurement... 15:20:26 Voltage Offset Correction: v_off_ini = 621.517 uV, v_off_fin = 606.019 uV 15:20:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.991 uVs 15:20:26 Integrated Voltage Measurement... 15:20:35 Voltage Offset Correction: v_off_ini = 600.602 uV, v_off_fin = 603.539 uV 15:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.639 uVs 15:20:35 Integrated Voltage Measurement... 15:20:44 Voltage Offset Correction: v_off_ini = 595.094 uV, v_off_fin = 589.914 uV 15:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.705 uVs 15:20:49 I1X Average and RMS of Measurements VT = -75.671 +- 10.218 uVs I1X = 15.135 +- 2.044 uTm 15:20:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:55 Integrated Voltage Measurement... 15:21:04 Voltage Offset Correction: v_off_ini = 585.201 uV, v_off_fin = 587.321 uV 15:21:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.918 uVs 15:21:04 Integrated Voltage Measurement... 15:21:13 Voltage Offset Correction: v_off_ini = 597.616 uV, v_off_fin = 613.471 uV 15:21:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.352 uVs 15:21:13 Integrated Voltage Measurement... 15:21:22 Voltage Offset Correction: v_off_ini = 601.876 uV, v_off_fin = 591.486 uV 15:21:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.823 uVs 15:21:22 Integrated Voltage Measurement... 15:21:31 Voltage Offset Correction: v_off_ini = 607.481 uV, v_off_fin = 618.300 uV 15:21:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.978 uVs 15:21:31 Integrated Voltage Measurement... 15:21:40 Voltage Offset Correction: v_off_ini = 601.865 uV, v_off_fin = 596.809 uV 15:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -202.559 uVs 15:21:40 Integrated Voltage Measurement... 15:21:49 Voltage Offset Correction: v_off_ini = 611.328 uV, v_off_fin = 631.621 uV 15:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.880 uVs 15:21:53 I1Y Average and RMS of Measurements VT = -195.418 +- 0.575 uVs I1Y = -39.081 +- 0.114 uTm 15:21:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:22:01 Integrated Voltage Measurement... 15:22:10 Voltage Offset Correction: v_off_ini = 612.258 uV, v_off_fin = 604.971 uV 15:22:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.131 uVs 15:22:10 Integrated Voltage Measurement... 15:22:19 Voltage Offset Correction: v_off_ini = 608.207 uV, v_off_fin = 619.399 uV 15:22:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.468 uVs 15:22:19 Integrated Voltage Measurement... 15:22:28 Voltage Offset Correction: v_off_ini = 625.991 uV, v_off_fin = 605.022 uV 15:22:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.884 uVs 15:22:28 Integrated Voltage Measurement... 15:22:37 Voltage Offset Correction: v_off_ini = 619.577 uV, v_off_fin = 620.851 uV 15:22:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.834 uVs 15:22:37 Integrated Voltage Measurement... 15:22:46 Voltage Offset Correction: v_off_ini = 611.725 uV, v_off_fin = 602.910 uV 15:22:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.146 uVs 15:22:46 Integrated Voltage Measurement... 15:22:55 Voltage Offset Correction: v_off_ini = 607.787 uV, v_off_fin = 628.133 uV 15:22:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.790 uVs 15:22:58 I2X Average and RMS of Measurements VT = -88.709 +- 2.292 uVs I2X = 8.161 +- 0.211 uTm^2 15:23:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:05 Integrated Voltage Measurement... 15:23:14 Voltage Offset Correction: v_off_ini = 646.555 uV, v_off_fin = 637.800 uV 15:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.123 uVs 15:23:14 Integrated Voltage Measurement... 15:23:23 Voltage Offset Correction: v_off_ini = 652.335 uV, v_off_fin = 660.142 uV 15:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 411.720 uVs 15:23:23 Integrated Voltage Measurement... 15:23:32 Voltage Offset Correction: v_off_ini = 643.309 uV, v_off_fin = 634.360 uV 15:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -411.689 uVs 15:23:32 Integrated Voltage Measurement... 15:23:41 Voltage Offset Correction: v_off_ini = 626.857 uV, v_off_fin = 632.723 uV 15:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.456 uVs 15:23:41 Integrated Voltage Measurement... 15:23:50 Voltage Offset Correction: v_off_ini = 648.209 uV, v_off_fin = 625.398 uV 15:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -413.959 uVs 15:23:51 Integrated Voltage Measurement... 15:23:59 Voltage Offset Correction: v_off_ini = 626.154 uV, v_off_fin = 622.973 uV 15:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 413.406 uVs 15:24:02 I2Y Average and RMS of Measurements VT = -410.892 +- 4.479 uVs I2Y = -37.802 +- 0.412 uTm^2 15:24:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:17 Integrated Voltage Measurement... 15:24:26 Voltage Offset Correction: v_off_ini = 637.784 uV, v_off_fin = 626.903 uV 15:24:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -81.134 uVs 15:24:26 Integrated Voltage Measurement... 15:24:35 Voltage Offset Correction: v_off_ini = 636.989 uV, v_off_fin = 646.386 uV 15:24:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.221 uVs 15:24:35 Integrated Voltage Measurement... 15:24:44 Voltage Offset Correction: v_off_ini = 632.342 uV, v_off_fin = 625.288 uV 15:24:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.893 uVs 15:24:44 Integrated Voltage Measurement... 15:24:53 Voltage Offset Correction: v_off_ini = 634.382 uV, v_off_fin = 646.504 uV 15:24:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.712 uVs 15:24:53 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 656.373 uV, v_off_fin = 645.415 uV 15:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.697 uVs 15:25:02 Integrated Voltage Measurement... 15:25:11 Voltage Offset Correction: v_off_ini = 651.892 uV, v_off_fin = 649.815 uV 15:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.227 uVs 15:25:15 I1X Average and RMS of Measurements VT = -78.981 +- 7.777 uVs I1X = 15.797 +- 1.556 uTm 15:25:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:22 Integrated Voltage Measurement... 15:25:31 Voltage Offset Correction: v_off_ini = 624.382 uV, v_off_fin = 630.119 uV 15:25:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.920 uVs 15:25:31 Integrated Voltage Measurement... 15:25:40 Voltage Offset Correction: v_off_ini = 647.820 uV, v_off_fin = 666.474 uV 15:25:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.308 uVs 15:25:40 Integrated Voltage Measurement... 15:25:49 Voltage Offset Correction: v_off_ini = 635.395 uV, v_off_fin = 623.861 uV 15:25:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.968 uVs 15:25:49 Integrated Voltage Measurement... 15:25:58 Voltage Offset Correction: v_off_ini = 642.155 uV, v_off_fin = 654.860 uV 15:25:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.723 uVs 15:25:58 Integrated Voltage Measurement... 15:26:07 Voltage Offset Correction: v_off_ini = 645.932 uV, v_off_fin = 635.812 uV 15:26:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.534 uVs 15:26:07 Integrated Voltage Measurement... 15:26:16 Voltage Offset Correction: v_off_ini = 645.766 uV, v_off_fin = 665.189 uV 15:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.943 uVs 15:26:20 I1Y Average and RMS of Measurements VT = -188.899 +- 3.999 uVs I1Y = -37.777 +- 0.799 uTm 15:26:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:28 Integrated Voltage Measurement... 15:26:37 Voltage Offset Correction: v_off_ini = 660.941 uV, v_off_fin = 651.170 uV 15:26:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -108.743 uVs 15:26:37 Integrated Voltage Measurement... 15:26:46 Voltage Offset Correction: v_off_ini = 654.532 uV, v_off_fin = 672.733 uV 15:26:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.472 uVs 15:26:46 Integrated Voltage Measurement... 15:26:55 Voltage Offset Correction: v_off_ini = 664.311 uV, v_off_fin = 652.251 uV 15:26:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.628 uVs 15:26:55 Integrated Voltage Measurement... 15:27:04 Voltage Offset Correction: v_off_ini = 660.713 uV, v_off_fin = 666.648 uV 15:27:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.773 uVs 15:27:04 Integrated Voltage Measurement... 15:27:13 Voltage Offset Correction: v_off_ini = 652.656 uV, v_off_fin = 645.493 uV 15:27:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -93.258 uVs 15:27:13 Integrated Voltage Measurement... 15:27:22 Voltage Offset Correction: v_off_ini = 655.230 uV, v_off_fin = 655.603 uV 15:27:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.061 uVs 15:27:24 I2X Average and RMS of Measurements VT = -93.656 +- 7.395 uVs I2X = 8.617 +- 0.680 uTm^2 15:27:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:32 Integrated Voltage Measurement... 15:27:41 Voltage Offset Correction: v_off_ini = 648.592 uV, v_off_fin = 660.553 uV 15:27:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -404.777 uVs 15:27:41 Integrated Voltage Measurement... 15:27:50 Voltage Offset Correction: v_off_ini = 638.321 uV, v_off_fin = 651.440 uV 15:27:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 410.410 uVs 15:27:50 Integrated Voltage Measurement... 15:27:59 Voltage Offset Correction: v_off_ini = 647.064 uV, v_off_fin = 661.338 uV 15:27:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -416.361 uVs 15:27:59 Integrated Voltage Measurement... 15:28:08 Voltage Offset Correction: v_off_ini = 676.025 uV, v_off_fin = 670.735 uV 15:28:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.477 uVs 15:28:08 Integrated Voltage Measurement... 15:28:17 Voltage Offset Correction: v_off_ini = 677.158 uV, v_off_fin = 678.622 uV 15:28:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.851 uVs 15:28:17 Integrated Voltage Measurement... 15:28:26 Voltage Offset Correction: v_off_ini = 675.704 uV, v_off_fin = 671.780 uV 15:28:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 398.469 uVs 15:28:28 I2Y Average and RMS of Measurements VT = -408.391 +- 0.640 uVs I2Y = -37.573 +- 0.058 uTm^2 15:28:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:43 Integrated Voltage Measurement... 15:28:52 Voltage Offset Correction: v_off_ini = 676.511 uV, v_off_fin = 673.850 uV 15:28:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.596 uVs 15:28:52 Integrated Voltage Measurement... 15:29:01 Voltage Offset Correction: v_off_ini = 665.860 uV, v_off_fin = 662.232 uV 15:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.383 uVs 15:29:01 Integrated Voltage Measurement... 15:29:10 Voltage Offset Correction: v_off_ini = 663.463 uV, v_off_fin = 665.689 uV 15:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.973 uVs 15:29:10 Integrated Voltage Measurement... 15:29:19 Voltage Offset Correction: v_off_ini = 666.497 uV, v_off_fin = 667.893 uV 15:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.700 uVs 15:29:19 Integrated Voltage Measurement... 15:29:28 Voltage Offset Correction: v_off_ini = 663.716 uV, v_off_fin = 665.348 uV 15:29:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.859 uVs 15:29:28 Integrated Voltage Measurement... 15:29:37 Voltage Offset Correction: v_off_ini = 667.548 uV, v_off_fin = 679.282 uV 15:29:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 35.736 uVs 15:29:42 I1X Average and RMS of Measurements VT = -71.208 +- 11.960 uVs I1X = 14.243 +- 2.392 uTm 15:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:48 Integrated Voltage Measurement... 15:29:57 Voltage Offset Correction: v_off_ini = 670.047 uV, v_off_fin = 662.111 uV 15:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -172.107 uVs 15:29:57 Integrated Voltage Measurement... 15:30:06 Voltage Offset Correction: v_off_ini = 671.564 uV, v_off_fin = 696.300 uV 15:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 182.107 uVs 15:30:06 Integrated Voltage Measurement... 15:30:15 Voltage Offset Correction: v_off_ini = 677.981 uV, v_off_fin = 660.008 uV 15:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.998 uVs 15:30:15 Integrated Voltage Measurement... 15:30:24 Voltage Offset Correction: v_off_ini = 685.013 uV, v_off_fin = 687.479 uV 15:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.643 uVs 15:30:24 Integrated Voltage Measurement... 15:30:33 Voltage Offset Correction: v_off_ini = 685.395 uV, v_off_fin = 673.017 uV 15:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.411 uVs 15:30:33 Integrated Voltage Measurement... 15:30:42 Voltage Offset Correction: v_off_ini = 676.309 uV, v_off_fin = 688.295 uV 15:30:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 167.460 uVs 15:30:46 I1Y Average and RMS of Measurements VT = -182.788 +- 4.579 uVs I1Y = -36.556 +- 0.916 uTm 15:30:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:54 Integrated Voltage Measurement... 15:31:03 Voltage Offset Correction: v_off_ini = 667.626 uV, v_off_fin = 665.960 uV 15:31:03 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.964 uVs 15:31:03 Integrated Voltage Measurement... 15:31:12 Voltage Offset Correction: v_off_ini = 666.181 uV, v_off_fin = 661.469 uV 15:31:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.984 uVs 15:31:12 Integrated Voltage Measurement... 15:31:21 Voltage Offset Correction: v_off_ini = 665.406 uV, v_off_fin = 651.826 uV 15:31:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.897 uVs 15:31:21 Integrated Voltage Measurement... 15:31:30 Voltage Offset Correction: v_off_ini = 652.933 uV, v_off_fin = 664.246 uV 15:31:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.903 uVs 15:31:30 Integrated Voltage Measurement... 15:31:39 Voltage Offset Correction: v_off_ini = 637.769 uV, v_off_fin = 640.563 uV 15:31:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.324 uVs 15:31:39 Integrated Voltage Measurement... 15:31:48 Voltage Offset Correction: v_off_ini = 651.084 uV, v_off_fin = 668.181 uV 15:31:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.245 uVs 15:31:51 I2X Average and RMS of Measurements VT = -86.720 +- 5.391 uVs I2X = 7.978 +- 0.496 uTm^2 15:31:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:58 Integrated Voltage Measurement... 15:32:07 Voltage Offset Correction: v_off_ini = 643.838 uV, v_off_fin = 646.846 uV 15:32:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -396.141 uVs 15:32:07 Integrated Voltage Measurement... 15:32:16 Voltage Offset Correction: v_off_ini = 652.927 uV, v_off_fin = 649.581 uV 15:32:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.636 uVs 15:32:16 Integrated Voltage Measurement... 15:32:25 Voltage Offset Correction: v_off_ini = 645.842 uV, v_off_fin = 651.123 uV 15:32:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.958 uVs 15:32:25 Integrated Voltage Measurement... 15:32:34 Voltage Offset Correction: v_off_ini = 640.610 uV, v_off_fin = 643.269 uV 15:32:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.375 uVs 15:32:34 Integrated Voltage Measurement... 15:32:43 Voltage Offset Correction: v_off_ini = 641.069 uV, v_off_fin = 652.578 uV 15:32:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.107 uVs 15:32:43 Integrated Voltage Measurement... 15:32:52 Voltage Offset Correction: v_off_ini = 645.665 uV, v_off_fin = 646.807 uV 15:32:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.072 uVs 15:32:55 I2Y Average and RMS of Measurements VT = -391.381 +- 4.541 uVs I2Y = -36.008 +- 0.418 uTm^2 15:33:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:10 Integrated Voltage Measurement... 15:33:19 Voltage Offset Correction: v_off_ini = 671.016 uV, v_off_fin = 652.918 uV 15:33:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -74.704 uVs 15:33:19 Integrated Voltage Measurement... 15:33:28 Voltage Offset Correction: v_off_ini = 653.303 uV, v_off_fin = 651.889 uV 15:33:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.524 uVs 15:33:28 Integrated Voltage Measurement... 15:33:37 Voltage Offset Correction: v_off_ini = 645.196 uV, v_off_fin = 653.761 uV 15:33:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.090 uVs 15:33:37 Integrated Voltage Measurement... 15:33:46 Voltage Offset Correction: v_off_ini = 642.751 uV, v_off_fin = 631.204 uV 15:33:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.491 uVs 15:33:46 Integrated Voltage Measurement... 15:33:55 Voltage Offset Correction: v_off_ini = 636.243 uV, v_off_fin = 642.644 uV 15:33:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.536 uVs 15:33:55 Integrated Voltage Measurement... 15:34:04 Voltage Offset Correction: v_off_ini = 640.971 uV, v_off_fin = 643.345 uV 15:34:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.625 uVs 15:34:08 I1X Average and RMS of Measurements VT = -78.162 +- 0.835 uVs I1X = 15.633 +- 0.168 uTm 15:34:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:15 Integrated Voltage Measurement... 15:34:24 Voltage Offset Correction: v_off_ini = 635.708 uV, v_off_fin = 622.893 uV 15:34:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.380 uVs 15:34:24 Integrated Voltage Measurement... 15:34:33 Voltage Offset Correction: v_off_ini = 642.586 uV, v_off_fin = 656.656 uV 15:34:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.263 uVs 15:34:33 Integrated Voltage Measurement... 15:34:42 Voltage Offset Correction: v_off_ini = 633.747 uV, v_off_fin = 641.979 uV 15:34:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.420 uVs 15:34:42 Integrated Voltage Measurement... 15:34:51 Voltage Offset Correction: v_off_ini = 659.908 uV, v_off_fin = 661.448 uV 15:34:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.434 uVs 15:34:51 Integrated Voltage Measurement... 15:35:00 Voltage Offset Correction: v_off_ini = 654.795 uV, v_off_fin = 645.903 uV 15:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.749 uVs 15:35:00 Integrated Voltage Measurement... 15:35:09 Voltage Offset Correction: v_off_ini = 640.555 uV, v_off_fin = 667.503 uV 15:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 190.781 uVs 15:35:13 I1Y Average and RMS of Measurements VT = -184.671 +- 2.947 uVs I1Y = -36.932 +- 0.590 uTm 15:35:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:21 Integrated Voltage Measurement... 15:35:30 Voltage Offset Correction: v_off_ini = 653.722 uV, v_off_fin = 649.006 uV 15:35:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -98.731 uVs 15:35:30 Integrated Voltage Measurement... 15:35:39 Voltage Offset Correction: v_off_ini = 652.651 uV, v_off_fin = 644.562 uV 15:35:39 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 79.673 uVs 15:35:39 Integrated Voltage Measurement... 15:35:48 Voltage Offset Correction: v_off_ini = 628.950 uV, v_off_fin = 622.813 uV 15:35:48 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -99.078 uVs 15:35:48 Integrated Voltage Measurement... 15:35:57 Voltage Offset Correction: v_off_ini = 638.662 uV, v_off_fin = 657.011 uV 15:35:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.325 uVs 15:35:57 Integrated Voltage Measurement... 15:36:06 Voltage Offset Correction: v_off_ini = 649.840 uV, v_off_fin = 630.838 uV 15:36:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -93.039 uVs 15:36:06 Integrated Voltage Measurement... 15:36:15 Voltage Offset Correction: v_off_ini = 650.185 uV, v_off_fin = 644.111 uV 15:36:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.123 uVs 15:36:17 I2X Average and RMS of Measurements VT = -85.661 +- 2.686 uVs I2X = 7.882 +- 0.247 uTm^2 15:36:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:25 Integrated Voltage Measurement... 15:36:34 Voltage Offset Correction: v_off_ini = 643.760 uV, v_off_fin = 635.186 uV 15:36:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -365.190 uVs 15:36:34 Integrated Voltage Measurement... 15:36:43 Voltage Offset Correction: v_off_ini = 646.383 uV, v_off_fin = 651.983 uV 15:36:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.891 uVs 15:36:43 Integrated Voltage Measurement... 15:36:52 Voltage Offset Correction: v_off_ini = 647.146 uV, v_off_fin = 656.663 uV 15:36:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.865 uVs 15:36:52 Integrated Voltage Measurement... 15:37:01 Voltage Offset Correction: v_off_ini = 641.458 uV, v_off_fin = 646.681 uV 15:37:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.529 uVs 15:37:01 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 641.696 uV, v_off_fin = 634.166 uV 15:37:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.287 uVs 15:37:10 Integrated Voltage Measurement... 15:37:19 Voltage Offset Correction: v_off_ini = 640.323 uV, v_off_fin = 654.358 uV 15:37:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.599 uVs 15:37:22 I2Y Average and RMS of Measurements VT = -381.727 +- 5.281 uVs I2Y = -35.119 +- 0.485 uTm^2 15:37:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:36 Integrated Voltage Measurement... 15:37:45 Voltage Offset Correction: v_off_ini = 646.686 uV, v_off_fin = 641.001 uV 15:37:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.476 uVs 15:37:45 Integrated Voltage Measurement... 15:37:54 Voltage Offset Correction: v_off_ini = 655.407 uV, v_off_fin = 649.477 uV 15:37:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.963 uVs 15:37:54 Integrated Voltage Measurement... 15:38:03 Voltage Offset Correction: v_off_ini = 651.280 uV, v_off_fin = 642.887 uV 15:38:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.797 uVs 15:38:03 Integrated Voltage Measurement... 15:38:12 Voltage Offset Correction: v_off_ini = 654.258 uV, v_off_fin = 654.700 uV 15:38:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.661 uVs 15:38:13 Integrated Voltage Measurement... 15:38:21 Voltage Offset Correction: v_off_ini = 642.732 uV, v_off_fin = 647.454 uV 15:38:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.698 uVs 15:38:22 Integrated Voltage Measurement... 15:38:30 Voltage Offset Correction: v_off_ini = 653.982 uV, v_off_fin = 654.441 uV 15:38:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.198 uVs 15:38:35 I1X Average and RMS of Measurements VT = -73.632 +- 7.090 uVs I1X = 14.727 +- 1.418 uTm 15:38:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:41 Integrated Voltage Measurement... 15:38:50 Voltage Offset Correction: v_off_ini = 653.308 uV, v_off_fin = 637.329 uV 15:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.644 uVs 15:38:50 Integrated Voltage Measurement... 15:38:59 Voltage Offset Correction: v_off_ini = 655.880 uV, v_off_fin = 675.299 uV 15:38:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.164 uVs 15:38:59 Integrated Voltage Measurement... 15:39:08 Voltage Offset Correction: v_off_ini = 665.268 uV, v_off_fin = 645.249 uV 15:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.817 uVs 15:39:08 Integrated Voltage Measurement... 15:39:17 Voltage Offset Correction: v_off_ini = 657.701 uV, v_off_fin = 670.470 uV 15:39:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.184 uVs 15:39:17 Integrated Voltage Measurement... 15:39:26 Voltage Offset Correction: v_off_ini = 663.458 uV, v_off_fin = 645.782 uV 15:39:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.993 uVs 15:39:26 Integrated Voltage Measurement... 15:39:35 Voltage Offset Correction: v_off_ini = 658.521 uV, v_off_fin = 674.703 uV 15:39:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.464 uVs 15:39:40 I1Y Average and RMS of Measurements VT = -176.711 +- 4.343 uVs I1Y = -35.340 +- 0.867 uTm 15:39:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:47 Integrated Voltage Measurement... 15:39:56 Voltage Offset Correction: v_off_ini = 647.556 uV, v_off_fin = 645.566 uV 15:39:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.138 uVs 15:39:56 Integrated Voltage Measurement... 15:40:05 Voltage Offset Correction: v_off_ini = 656.447 uV, v_off_fin = 651.503 uV 15:40:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.442 uVs 15:40:05 Integrated Voltage Measurement... 15:40:14 Voltage Offset Correction: v_off_ini = 645.616 uV, v_off_fin = 652.302 uV 15:40:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.135 uVs 15:40:14 Integrated Voltage Measurement... 15:40:23 Voltage Offset Correction: v_off_ini = 666.884 uV, v_off_fin = 671.044 uV 15:40:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.189 uVs 15:40:23 Integrated Voltage Measurement... 15:40:32 Voltage Offset Correction: v_off_ini = 660.470 uV, v_off_fin = 654.044 uV 15:40:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.203 uVs 15:40:32 Integrated Voltage Measurement... 15:40:41 Voltage Offset Correction: v_off_ini = 655.987 uV, v_off_fin = 675.219 uV 15:40:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.519 uVs 15:40:44 I2X Average and RMS of Measurements VT = -88.271 +- 2.316 uVs I2X = 8.121 +- 0.213 uTm^2 15:40:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:51 Integrated Voltage Measurement... 15:41:00 Voltage Offset Correction: v_off_ini = 656.437 uV, v_off_fin = 663.273 uV 15:41:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -360.031 uVs 15:41:00 Integrated Voltage Measurement... 15:41:09 Voltage Offset Correction: v_off_ini = 655.152 uV, v_off_fin = 660.427 uV 15:41:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.148 uVs 15:41:10 Integrated Voltage Measurement... 15:41:18 Voltage Offset Correction: v_off_ini = 659.011 uV, v_off_fin = 660.898 uV 15:41:19 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -380.123 uVs 15:41:19 Integrated Voltage Measurement... 15:41:28 Voltage Offset Correction: v_off_ini = 663.538 uV, v_off_fin = 656.781 uV 15:41:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.746 uVs 15:41:28 Integrated Voltage Measurement... 15:41:37 Voltage Offset Correction: v_off_ini = 658.964 uV, v_off_fin = 664.934 uV 15:41:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.943 uVs 15:41:37 Integrated Voltage Measurement... 15:41:46 Voltage Offset Correction: v_off_ini = 662.177 uV, v_off_fin = 653.091 uV 15:41:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.466 uVs 15:41:48 I2Y Average and RMS of Measurements VT = -376.576 +- 4.439 uVs I2Y = -34.645 +- 0.407 uTm^2 15:42:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:04 Integrated Voltage Measurement... 15:42:13 Voltage Offset Correction: v_off_ini = 667.717 uV, v_off_fin = 664.054 uV 15:42:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.959 uVs 15:42:13 Integrated Voltage Measurement... 15:42:22 Voltage Offset Correction: v_off_ini = 669.331 uV, v_off_fin = 673.752 uV 15:42:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.178 uVs 15:42:22 Integrated Voltage Measurement... 15:42:31 Voltage Offset Correction: v_off_ini = 683.686 uV, v_off_fin = 664.139 uV 15:42:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.244 uVs 15:42:31 Integrated Voltage Measurement... 15:42:40 Voltage Offset Correction: v_off_ini = 676.646 uV, v_off_fin = 679.814 uV 15:42:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.908 uVs 15:42:40 Integrated Voltage Measurement... 15:42:49 Voltage Offset Correction: v_off_ini = 642.627 uV, v_off_fin = 659.067 uV 15:42:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.860 uVs 15:42:49 Integrated Voltage Measurement... 15:42:58 Voltage Offset Correction: v_off_ini = 652.539 uV, v_off_fin = 664.965 uV 15:42:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.810 uVs 15:43:02 I1X Average and RMS of Measurements VT = -75.660 +- 5.248 uVs I1X = 15.133 +- 1.050 uTm 15:43:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:09 Integrated Voltage Measurement... 15:43:18 Voltage Offset Correction: v_off_ini = 661.564 uV, v_off_fin = 645.717 uV 15:43:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -153.510 uVs 15:43:18 Integrated Voltage Measurement... 15:43:27 Voltage Offset Correction: v_off_ini = 652.499 uV, v_off_fin = 673.915 uV 15:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.554 uVs 15:43:27 Integrated Voltage Measurement... 15:43:36 Voltage Offset Correction: v_off_ini = 637.304 uV, v_off_fin = 660.777 uV 15:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -155.568 uVs 15:43:36 Integrated Voltage Measurement... 15:43:45 Voltage Offset Correction: v_off_ini = 654.221 uV, v_off_fin = 684.732 uV 15:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 175.953 uVs 15:43:45 Integrated Voltage Measurement... 15:43:54 Voltage Offset Correction: v_off_ini = 671.069 uV, v_off_fin = 657.730 uV 15:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.501 uVs 15:43:54 Integrated Voltage Measurement... 15:44:03 Voltage Offset Correction: v_off_ini = 660.346 uV, v_off_fin = 679.428 uV 15:44:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 167.383 uVs 15:44:07 I1Y Average and RMS of Measurements VT = -168.411 +- 2.897 uVs I1Y = -33.679 +- 0.579 uTm 15:44:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:15 Integrated Voltage Measurement... 15:44:24 Voltage Offset Correction: v_off_ini = 687.330 uV, v_off_fin = 675.465 uV 15:44:24 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -102.040 uVs 15:44:24 Integrated Voltage Measurement... 15:44:33 Voltage Offset Correction: v_off_ini = 674.761 uV, v_off_fin = 677.241 uV 15:44:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.278 uVs 15:44:33 Integrated Voltage Measurement... 15:44:42 Voltage Offset Correction: v_off_ini = 674.212 uV, v_off_fin = 662.045 uV 15:44:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.506 uVs 15:44:42 Integrated Voltage Measurement... 15:44:51 Voltage Offset Correction: v_off_ini = 682.610 uV, v_off_fin = 686.609 uV 15:44:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.862 uVs 15:44:51 Integrated Voltage Measurement... 15:45:00 Voltage Offset Correction: v_off_ini = 672.256 uV, v_off_fin = 662.752 uV 15:45:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.362 uVs 15:45:00 Integrated Voltage Measurement... 15:45:09 Voltage Offset Correction: v_off_ini = 675.015 uV, v_off_fin = 682.377 uV 15:45:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.747 uVs 15:45:12 I2X Average and RMS of Measurements VT = -78.299 +- 6.047 uVs I2X = 7.204 +- 0.556 uTm^2 15:45:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:19 Integrated Voltage Measurement... 15:45:28 Voltage Offset Correction: v_off_ini = 680.847 uV, v_off_fin = 673.156 uV 15:45:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -357.049 uVs 15:45:28 Integrated Voltage Measurement... 15:45:37 Voltage Offset Correction: v_off_ini = 663.847 uV, v_off_fin = 661.257 uV 15:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.993 uVs 15:45:37 Integrated Voltage Measurement... 15:45:46 Voltage Offset Correction: v_off_ini = 677.175 uV, v_off_fin = 673.302 uV 15:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.444 uVs 15:45:46 Integrated Voltage Measurement... 15:45:55 Voltage Offset Correction: v_off_ini = 670.403 uV, v_off_fin = 674.531 uV 15:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.910 uVs 15:45:55 Integrated Voltage Measurement... 15:46:04 Voltage Offset Correction: v_off_ini = 674.156 uV, v_off_fin = 670.141 uV 15:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.868 uVs 15:46:04 Integrated Voltage Measurement... 15:46:13 Voltage Offset Correction: v_off_ini = 676.770 uV, v_off_fin = 668.700 uV 15:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.827 uVs 15:46:16 I2Y Average and RMS of Measurements VT = -355.849 +- 6.486 uVs I2Y = -32.739 +- 0.598 uTm^2 15:46:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:32 Integrated Voltage Measurement... 15:46:41 Voltage Offset Correction: v_off_ini = 666.013 uV, v_off_fin = 671.224 uV 15:46:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.016 uVs 15:46:41 Integrated Voltage Measurement... 15:46:50 Voltage Offset Correction: v_off_ini = 673.470 uV, v_off_fin = 664.556 uV 15:46:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.330 uVs 15:46:50 Integrated Voltage Measurement... 15:46:59 Voltage Offset Correction: v_off_ini = 669.755 uV, v_off_fin = 664.180 uV 15:46:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.829 uVs 15:46:59 Integrated Voltage Measurement... 15:47:08 Voltage Offset Correction: v_off_ini = 663.740 uV, v_off_fin = 662.974 uV 15:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.641 uVs 15:47:08 Integrated Voltage Measurement... 15:47:17 Voltage Offset Correction: v_off_ini = 672.140 uV, v_off_fin = 666.184 uV 15:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.663 uVs 15:47:17 Integrated Voltage Measurement... 15:47:26 Voltage Offset Correction: v_off_ini = 674.655 uV, v_off_fin = 672.158 uV 15:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.058 uVs 15:47:30 I1X Average and RMS of Measurements VT = -76.256 +- 8.209 uVs I1X = 15.252 +- 1.642 uTm 15:47:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:37 Integrated Voltage Measurement... 15:47:46 Voltage Offset Correction: v_off_ini = 670.346 uV, v_off_fin = 664.689 uV 15:47:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.530 uVs 15:47:46 Integrated Voltage Measurement... 15:47:55 Voltage Offset Correction: v_off_ini = 669.546 uV, v_off_fin = 689.061 uV 15:47:55 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 169.540 uVs 15:47:55 Integrated Voltage Measurement... 15:48:04 Voltage Offset Correction: v_off_ini = 673.132 uV, v_off_fin = 668.984 uV 15:48:04 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -159.047 uVs 15:48:04 Integrated Voltage Measurement... 15:48:13 Voltage Offset Correction: v_off_ini = 691.936 uV, v_off_fin = 699.320 uV 15:48:13 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 152.392 uVs 15:48:13 Integrated Voltage Measurement... 15:48:22 Voltage Offset Correction: v_off_ini = 708.074 uV, v_off_fin = 679.914 uV 15:48:22 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -184.840 uVs 15:48:22 Integrated Voltage Measurement... 15:48:31 Voltage Offset Correction: v_off_ini = 682.727 uV, v_off_fin = 696.064 uV 15:48:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.668 uVs 15:48:35 I1Y Average and RMS of Measurements VT = -167.170 +- 8.844 uVs I1Y = -33.428 +- 1.770 uTm 15:48:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:43 Integrated Voltage Measurement... 15:48:52 Voltage Offset Correction: v_off_ini = 684.485 uV, v_off_fin = 675.325 uV 15:48:52 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -98.686 uVs 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = 685.571 uV, v_off_fin = 705.123 uV 15:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.208 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = 690.662 uV, v_off_fin = 679.390 uV 15:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.711 uVs 15:49:10 Integrated Voltage Measurement... 15:49:19 Voltage Offset Correction: v_off_ini = 690.629 uV, v_off_fin = 699.592 uV 15:49:19 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 84.405 uVs 15:49:19 Integrated Voltage Measurement... 15:49:28 Voltage Offset Correction: v_off_ini = 696.164 uV, v_off_fin = 682.403 uV 15:49:28 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -89.276 uVs 15:49:28 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = 677.932 uV, v_off_fin = 697.818 uV 15:49:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.658 uVs 15:49:39 I2X Average and RMS of Measurements VT = -88.824 +- 4.313 uVs I2X = 8.172 +- 0.396 uTm^2 15:49:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:47 Integrated Voltage Measurement... 15:49:56 Voltage Offset Correction: v_off_ini = 694.245 uV, v_off_fin = 697.803 uV 15:49:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -339.395 uVs 15:49:56 Integrated Voltage Measurement... 15:50:05 Voltage Offset Correction: v_off_ini = 691.415 uV, v_off_fin = 687.415 uV 15:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.382 uVs 15:50:05 Integrated Voltage Measurement... 15:50:14 Voltage Offset Correction: v_off_ini = 683.654 uV, v_off_fin = 673.861 uV 15:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.489 uVs 15:50:14 Integrated Voltage Measurement... 15:50:23 Voltage Offset Correction: v_off_ini = 663.558 uV, v_off_fin = 672.695 uV 15:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.627 uVs 15:50:23 Integrated Voltage Measurement... 15:50:32 Voltage Offset Correction: v_off_ini = 674.713 uV, v_off_fin = 676.999 uV 15:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.225 uVs 15:50:32 Integrated Voltage Measurement... 15:50:41 Voltage Offset Correction: v_off_ini = 674.008 uV, v_off_fin = 670.170 uV 15:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.589 uVs 15:50:44 I2Y Average and RMS of Measurements VT = -336.618 +- 6.378 uVs I2Y = -30.969 +- 0.588 uTm^2 15:50:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:02 Integrated Voltage Measurement... 15:51:11 Voltage Offset Correction: v_off_ini = 677.358 uV, v_off_fin = 675.879 uV 15:51:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.803 uVs 15:51:11 Integrated Voltage Measurement... 15:51:20 Voltage Offset Correction: v_off_ini = 673.572 uV, v_off_fin = 667.900 uV 15:51:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 83.180 uVs 15:51:20 Integrated Voltage Measurement... 15:51:29 Voltage Offset Correction: v_off_ini = 672.727 uV, v_off_fin = 671.063 uV 15:51:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.105 uVs 15:51:29 Integrated Voltage Measurement... 15:51:38 Voltage Offset Correction: v_off_ini = 675.369 uV, v_off_fin = 674.793 uV 15:51:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.122 uVs 15:51:38 Integrated Voltage Measurement... 15:51:47 Voltage Offset Correction: v_off_ini = 667.793 uV, v_off_fin = 656.520 uV 15:51:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.890 uVs 15:51:47 Integrated Voltage Measurement... 15:51:56 Voltage Offset Correction: v_off_ini = 665.876 uV, v_off_fin = 676.867 uV 15:51:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.249 uVs 15:52:00 I1X Average and RMS of Measurements VT = -70.558 +- 10.428 uVs I1X = 14.113 +- 2.087 uTm 15:52:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:07 Integrated Voltage Measurement... 15:52:16 Voltage Offset Correction: v_off_ini = 662.206 uV, v_off_fin = 649.110 uV 15:52:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.552 uVs 15:52:16 Integrated Voltage Measurement... 15:52:25 Voltage Offset Correction: v_off_ini = 650.592 uV, v_off_fin = 665.515 uV 15:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 161.004 uVs 15:52:25 Integrated Voltage Measurement... 15:52:34 Voltage Offset Correction: v_off_ini = 637.648 uV, v_off_fin = 633.640 uV 15:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -151.740 uVs 15:52:34 Integrated Voltage Measurement... 15:52:43 Voltage Offset Correction: v_off_ini = 667.118 uV, v_off_fin = 672.591 uV 15:52:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.494 uVs 15:52:43 Integrated Voltage Measurement... 15:52:52 Voltage Offset Correction: v_off_ini = 669.494 uV, v_off_fin = 664.230 uV 15:52:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -149.050 uVs 15:52:52 Integrated Voltage Measurement... 15:53:01 Voltage Offset Correction: v_off_ini = 670.290 uV, v_off_fin = 675.883 uV 15:53:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 163.799 uVs 15:53:05 I1Y Average and RMS of Measurements VT = -160.940 +- 3.228 uVs I1Y = -32.185 +- 0.645 uTm 15:53:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:13 Integrated Voltage Measurement... 15:53:22 Voltage Offset Correction: v_off_ini = 666.777 uV, v_off_fin = 648.507 uV 15:53:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -95.760 uVs 15:53:22 Integrated Voltage Measurement... 15:53:31 Voltage Offset Correction: v_off_ini = 660.004 uV, v_off_fin = 666.843 uV 15:53:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.197 uVs 15:53:31 Integrated Voltage Measurement... 15:53:40 Voltage Offset Correction: v_off_ini = 649.832 uV, v_off_fin = 654.010 uV 15:53:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.303 uVs 15:53:40 Integrated Voltage Measurement... 15:53:49 Voltage Offset Correction: v_off_ini = 651.841 uV, v_off_fin = 661.754 uV 15:53:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.382 uVs 15:53:49 Integrated Voltage Measurement... 15:53:58 Voltage Offset Correction: v_off_ini = 645.558 uV, v_off_fin = 651.716 uV 15:53:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.233 uVs 15:53:58 Integrated Voltage Measurement... 15:54:07 Voltage Offset Correction: v_off_ini = 664.511 uV, v_off_fin = 673.144 uV 15:54:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.226 uVs 15:54:09 I2X Average and RMS of Measurements VT = -81.350 +- 10.061 uVs I2X = 7.484 +- 0.925 uTm^2 15:54:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:17 Integrated Voltage Measurement... 15:54:26 Voltage Offset Correction: v_off_ini = 660.309 uV, v_off_fin = 656.018 uV 15:54:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.948 uVs 15:54:26 Integrated Voltage Measurement... 15:54:35 Voltage Offset Correction: v_off_ini = 671.712 uV, v_off_fin = 668.351 uV 15:54:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.292 uVs 15:54:35 Integrated Voltage Measurement... 15:54:44 Voltage Offset Correction: v_off_ini = 668.664 uV, v_off_fin = 645.492 uV 15:54:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.637 uVs 15:54:44 Integrated Voltage Measurement... 15:54:53 Voltage Offset Correction: v_off_ini = 650.008 uV, v_off_fin = 641.611 uV 15:54:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.635 uVs 15:54:53 Integrated Voltage Measurement... 15:55:02 Voltage Offset Correction: v_off_ini = 647.145 uV, v_off_fin = 650.992 uV 15:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.306 uVs 15:55:02 Integrated Voltage Measurement... 15:55:11 Voltage Offset Correction: v_off_ini = 658.687 uV, v_off_fin = 660.751 uV 15:55:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.438 uVs 15:55:14 I2Y Average and RMS of Measurements VT = -325.543 +- 5.647 uVs I2Y = -29.950 +- 0.520 uTm^2 15:55:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = 662.976 uV, v_off_fin = 675.838 uV 15:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.316 uVs 15:55:41 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = 672.480 uV, v_off_fin = 679.404 uV 15:55:50 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 73.664 uVs 15:55:50 Integrated Voltage Measurement... 15:55:59 Voltage Offset Correction: v_off_ini = 661.687 uV, v_off_fin = 678.536 uV 15:55:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.672 uVs 15:55:59 Integrated Voltage Measurement... 15:56:08 Voltage Offset Correction: v_off_ini = 682.997 uV, v_off_fin = 673.050 uV 15:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.547 uVs 15:56:08 Integrated Voltage Measurement... 15:56:17 Voltage Offset Correction: v_off_ini = 674.450 uV, v_off_fin = 675.994 uV 15:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.352 uVs 15:56:17 Integrated Voltage Measurement... 15:56:26 Voltage Offset Correction: v_off_ini = 658.575 uV, v_off_fin = 670.412 uV 15:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.918 uVs 15:56:30 I1X Average and RMS of Measurements VT = -68.911 +- 8.364 uVs I1X = 13.783 +- 1.673 uTm 15:56:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:37 Integrated Voltage Measurement... 15:56:46 Voltage Offset Correction: v_off_ini = 661.156 uV, v_off_fin = 655.039 uV 15:56:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.563 uVs 15:56:46 Integrated Voltage Measurement... 15:56:55 Voltage Offset Correction: v_off_ini = 668.531 uV, v_off_fin = 680.997 uV 15:56:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.643 uVs 15:56:55 Integrated Voltage Measurement... 15:57:04 Voltage Offset Correction: v_off_ini = 659.516 uV, v_off_fin = 655.325 uV 15:57:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.389 uVs 15:57:04 Integrated Voltage Measurement... 15:57:13 Voltage Offset Correction: v_off_ini = 661.238 uV, v_off_fin = 667.663 uV 15:57:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 158.107 uVs 15:57:13 Integrated Voltage Measurement... 15:57:22 Voltage Offset Correction: v_off_ini = 669.417 uV, v_off_fin = 657.741 uV 15:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.737 uVs 15:57:22 Integrated Voltage Measurement... 15:57:31 Voltage Offset Correction: v_off_ini = 676.275 uV, v_off_fin = 679.797 uV 15:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 166.680 uVs 15:57:35 I1Y Average and RMS of Measurements VT = -170.020 +- 3.538 uVs I1Y = -34.001 +- 0.708 uTm 15:57:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:43 Integrated Voltage Measurement... 15:57:52 Voltage Offset Correction: v_off_ini = 684.727 uV, v_off_fin = 668.641 uV 15:57:52 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -98.389 uVs 15:57:52 Integrated Voltage Measurement... 15:58:01 Voltage Offset Correction: v_off_ini = 673.987 uV, v_off_fin = 692.536 uV 15:58:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.930 uVs 15:58:01 Integrated Voltage Measurement... 15:58:10 Voltage Offset Correction: v_off_ini = 679.853 uV, v_off_fin = 668.145 uV 15:58:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.431 uVs 15:58:10 Integrated Voltage Measurement... 15:58:19 Voltage Offset Correction: v_off_ini = 679.366 uV, v_off_fin = 691.371 uV 15:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.409 uVs 15:58:19 Integrated Voltage Measurement... 15:58:28 Voltage Offset Correction: v_off_ini = 677.645 uV, v_off_fin = 665.443 uV 15:58:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.473 uVs 15:58:28 Integrated Voltage Measurement... 15:58:37 Voltage Offset Correction: v_off_ini = 674.243 uV, v_off_fin = 685.529 uV 15:58:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.629 uVs 15:58:39 I2X Average and RMS of Measurements VT = -79.710 +- 11.684 uVs I2X = 7.333 +- 1.075 uTm^2 15:58:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:47 Integrated Voltage Measurement... 15:58:56 Voltage Offset Correction: v_off_ini = 687.507 uV, v_off_fin = 688.617 uV 15:58:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.424 uVs 15:58:56 Integrated Voltage Measurement... 15:59:05 Voltage Offset Correction: v_off_ini = 678.928 uV, v_off_fin = 685.606 uV 15:59:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.463 uVs 15:59:05 Integrated Voltage Measurement... 15:59:14 Voltage Offset Correction: v_off_ini = 680.515 uV, v_off_fin = 678.073 uV 15:59:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.222 uVs 15:59:14 Integrated Voltage Measurement... 15:59:23 Voltage Offset Correction: v_off_ini = 678.621 uV, v_off_fin = 671.284 uV 15:59:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.596 uVs 15:59:23 Integrated Voltage Measurement... 15:59:32 Voltage Offset Correction: v_off_ini = 665.841 uV, v_off_fin = 664.444 uV 15:59:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.851 uVs 15:59:32 Integrated Voltage Measurement... 15:59:41 Voltage Offset Correction: v_off_ini = 662.219 uV, v_off_fin = 660.943 uV 15:59:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.965 uVs 15:59:44 I2Y Average and RMS of Measurements VT = -304.420 +- 5.352 uVs I2Y = -28.007 +- 0.492 uTm^2 15:59:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:02 Integrated Voltage Measurement... 16:00:11 Voltage Offset Correction: v_off_ini = 668.046 uV, v_off_fin = 656.237 uV 16:00:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.894 uVs 16:00:11 Integrated Voltage Measurement... 16:00:20 Voltage Offset Correction: v_off_ini = 658.161 uV, v_off_fin = 671.775 uV 16:00:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.962 uVs 16:00:20 Integrated Voltage Measurement... 16:00:29 Voltage Offset Correction: v_off_ini = 659.111 uV, v_off_fin = 650.937 uV 16:00:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.836 uVs 16:00:29 Integrated Voltage Measurement... 16:00:38 Voltage Offset Correction: v_off_ini = 655.431 uV, v_off_fin = 663.202 uV 16:00:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 68.129 uVs 16:00:38 Integrated Voltage Measurement... 16:00:47 Voltage Offset Correction: v_off_ini = 661.296 uV, v_off_fin = 660.895 uV 16:00:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.095 uVs 16:00:47 Integrated Voltage Measurement... 16:00:56 Voltage Offset Correction: v_off_ini = 668.023 uV, v_off_fin = 673.766 uV 16:00:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.806 uVs 16:01:00 I1X Average and RMS of Measurements VT = -72.120 +- 1.197 uVs I1X = 14.425 +- 0.240 uTm 16:01:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:07 Integrated Voltage Measurement... 16:01:16 Voltage Offset Correction: v_off_ini = 679.899 uV, v_off_fin = 666.453 uV 16:01:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.577 uVs 16:01:16 Integrated Voltage Measurement... 16:01:25 Voltage Offset Correction: v_off_ini = 681.976 uV, v_off_fin = 687.883 uV 16:01:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.387 uVs 16:01:25 Integrated Voltage Measurement... 16:01:34 Voltage Offset Correction: v_off_ini = 673.247 uV, v_off_fin = 665.884 uV 16:01:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.567 uVs 16:01:34 Integrated Voltage Measurement... 16:01:43 Voltage Offset Correction: v_off_ini = 665.216 uV, v_off_fin = 693.567 uV 16:01:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.611 uVs 16:01:43 Integrated Voltage Measurement... 16:01:52 Voltage Offset Correction: v_off_ini = 681.390 uV, v_off_fin = 664.561 uV 16:01:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.325 uVs 16:01:52 Integrated Voltage Measurement... 16:02:01 Voltage Offset Correction: v_off_ini = 683.369 uV, v_off_fin = 688.574 uV 16:02:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.002 uVs 16:02:05 I1Y Average and RMS of Measurements VT = -179.745 +- 3.482 uVs I1Y = -35.947 +- 0.698 uTm 16:02:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:13 Integrated Voltage Measurement... 16:02:22 Voltage Offset Correction: v_off_ini = 686.831 uV, v_off_fin = 664.089 uV 16:02:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -81.789 uVs 16:02:22 Integrated Voltage Measurement... 16:02:31 Voltage Offset Correction: v_off_ini = 692.925 uV, v_off_fin = 690.797 uV 16:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.438 uVs 16:02:31 Integrated Voltage Measurement... 16:02:40 Voltage Offset Correction: v_off_ini = 689.571 uV, v_off_fin = 674.996 uV 16:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.082 uVs 16:02:40 Integrated Voltage Measurement... 16:02:49 Voltage Offset Correction: v_off_ini = 675.689 uV, v_off_fin = 686.633 uV 16:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.696 uVs 16:02:49 Integrated Voltage Measurement... 16:02:58 Voltage Offset Correction: v_off_ini = 679.930 uV, v_off_fin = 662.392 uV 16:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.078 uVs 16:02:58 Integrated Voltage Measurement... 16:03:07 Voltage Offset Correction: v_off_ini = 667.110 uV, v_off_fin = 676.427 uV 16:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.302 uVs 16:03:09 I2X Average and RMS of Measurements VT = -75.564 +- 2.785 uVs I2X = 6.952 +- 0.256 uTm^2 16:03:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:17 Integrated Voltage Measurement... 16:03:26 Voltage Offset Correction: v_off_ini = 677.916 uV, v_off_fin = 676.067 uV 16:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.867 uVs 16:03:26 Integrated Voltage Measurement... 16:03:35 Voltage Offset Correction: v_off_ini = 667.096 uV, v_off_fin = 662.441 uV 16:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.092 uVs 16:03:35 Integrated Voltage Measurement... 16:03:44 Voltage Offset Correction: v_off_ini = 668.099 uV, v_off_fin = 663.045 uV 16:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.266 uVs 16:03:44 Integrated Voltage Measurement... 16:03:53 Voltage Offset Correction: v_off_ini = 689.209 uV, v_off_fin = 685.357 uV 16:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.032 uVs 16:03:53 Integrated Voltage Measurement... 16:04:02 Voltage Offset Correction: v_off_ini = 688.912 uV, v_off_fin = 675.776 uV 16:04:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.378 uVs 16:04:02 Integrated Voltage Measurement... 16:04:11 Voltage Offset Correction: v_off_ini = 672.257 uV, v_off_fin = 675.236 uV 16:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.145 uVs 16:04:13 I2Y Average and RMS of Measurements VT = -301.130 +- 3.430 uVs I2Y = -27.704 +- 0.316 uTm^2 16:04:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:31 Integrated Voltage Measurement... 16:04:40 Voltage Offset Correction: v_off_ini = 697.345 uV, v_off_fin = 693.052 uV 16:04:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -85.123 uVs 16:04:40 Integrated Voltage Measurement... 16:04:49 Voltage Offset Correction: v_off_ini = 686.517 uV, v_off_fin = 691.716 uV 16:04:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.049 uVs 16:04:49 Integrated Voltage Measurement... 16:04:58 Voltage Offset Correction: v_off_ini = 692.735 uV, v_off_fin = 684.106 uV 16:04:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.664 uVs 16:04:58 Integrated Voltage Measurement... 16:05:07 Voltage Offset Correction: v_off_ini = 661.236 uV, v_off_fin = 679.791 uV 16:05:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.072 uVs 16:05:07 Integrated Voltage Measurement... 16:05:16 Voltage Offset Correction: v_off_ini = 666.619 uV, v_off_fin = 665.834 uV 16:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.778 uVs 16:05:16 Integrated Voltage Measurement... 16:05:25 Voltage Offset Correction: v_off_ini = 685.827 uV, v_off_fin = 688.608 uV 16:05:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.240 uVs 16:05:30 I1X Average and RMS of Measurements VT = -75.321 +- 8.467 uVs I1X = 15.065 +- 1.694 uTm 16:05:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:36 Integrated Voltage Measurement... 16:05:45 Voltage Offset Correction: v_off_ini = 676.206 uV, v_off_fin = 664.645 uV 16:05:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.559 uVs 16:05:45 Integrated Voltage Measurement... 16:05:54 Voltage Offset Correction: v_off_ini = 675.713 uV, v_off_fin = 684.402 uV 16:05:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.744 uVs 16:05:54 Integrated Voltage Measurement... 16:06:03 Voltage Offset Correction: v_off_ini = 687.194 uV, v_off_fin = 667.023 uV 16:06:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.082 uVs 16:06:03 Integrated Voltage Measurement... 16:06:12 Voltage Offset Correction: v_off_ini = 678.789 uV, v_off_fin = 686.688 uV 16:06:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.725 uVs 16:06:12 Integrated Voltage Measurement... 16:06:21 Voltage Offset Correction: v_off_ini = 666.373 uV, v_off_fin = 667.918 uV 16:06:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.647 uVs 16:06:21 Integrated Voltage Measurement... 16:06:30 Voltage Offset Correction: v_off_ini = 684.284 uV, v_off_fin = 690.775 uV 16:06:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.149 uVs 16:06:34 I1Y Average and RMS of Measurements VT = -184.651 +- 1.673 uVs I1Y = -36.930 +- 0.335 uTm 16:06:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:42 Integrated Voltage Measurement... 16:06:51 Voltage Offset Correction: v_off_ini = 668.524 uV, v_off_fin = 671.125 uV 16:06:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -55.972 uVs 16:06:51 Integrated Voltage Measurement... 16:07:00 Voltage Offset Correction: v_off_ini = 667.092 uV, v_off_fin = 680.837 uV 16:07:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.256 uVs 16:07:00 Integrated Voltage Measurement... 16:07:09 Voltage Offset Correction: v_off_ini = 670.650 uV, v_off_fin = 667.491 uV 16:07:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.891 uVs 16:07:09 Integrated Voltage Measurement... 16:07:18 Voltage Offset Correction: v_off_ini = 674.426 uV, v_off_fin = 683.829 uV 16:07:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.874 uVs 16:07:18 Integrated Voltage Measurement... 16:07:27 Voltage Offset Correction: v_off_ini = 673.008 uV, v_off_fin = 671.531 uV 16:07:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.808 uVs 16:07:27 Integrated Voltage Measurement... 16:07:36 Voltage Offset Correction: v_off_ini = 679.967 uV, v_off_fin = 688.820 uV 16:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.224 uVs 16:07:39 I2X Average and RMS of Measurements VT = -66.004 +- 7.326 uVs I2X = 6.072 +- 0.674 uTm^2 16:07:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:46 Integrated Voltage Measurement... 16:07:55 Voltage Offset Correction: v_off_ini = 693.412 uV, v_off_fin = 683.161 uV 16:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.135 uVs 16:07:55 Integrated Voltage Measurement... 16:08:04 Voltage Offset Correction: v_off_ini = 685.680 uV, v_off_fin = 684.123 uV 16:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.888 uVs 16:08:04 Integrated Voltage Measurement... 16:08:13 Voltage Offset Correction: v_off_ini = 688.768 uV, v_off_fin = 694.165 uV 16:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.377 uVs 16:08:13 Integrated Voltage Measurement... 16:08:22 Voltage Offset Correction: v_off_ini = 685.863 uV, v_off_fin = 697.429 uV 16:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.263 uVs 16:08:22 Integrated Voltage Measurement... 16:08:31 Voltage Offset Correction: v_off_ini = 680.835 uV, v_off_fin = 672.559 uV 16:08:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.093 uVs 16:08:31 Integrated Voltage Measurement... 16:08:40 Voltage Offset Correction: v_off_ini = 682.192 uV, v_off_fin = 681.902 uV 16:08:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.757 uVs 16:08:43 I2Y Average and RMS of Measurements VT = -300.252 +- 2.663 uVs I2Y = -27.623 +- 0.245 uTm^2 16:08:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:01 Integrated Voltage Measurement... 16:09:10 Voltage Offset Correction: v_off_ini = 691.589 uV, v_off_fin = 676.495 uV 16:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -73.747 uVs 16:09:10 Integrated Voltage Measurement... 16:09:19 Voltage Offset Correction: v_off_ini = 694.810 uV, v_off_fin = 692.307 uV 16:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.313 uVs 16:09:19 Integrated Voltage Measurement... 16:09:28 Voltage Offset Correction: v_off_ini = 691.316 uV, v_off_fin = 678.123 uV 16:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.168 uVs 16:09:28 Integrated Voltage Measurement... 16:09:37 Voltage Offset Correction: v_off_ini = 698.241 uV, v_off_fin = 691.656 uV 16:09:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.271 uVs 16:09:37 Integrated Voltage Measurement... 16:09:46 Voltage Offset Correction: v_off_ini = 690.380 uV, v_off_fin = 695.763 uV 16:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.250 uVs 16:09:46 Integrated Voltage Measurement... 16:09:55 Voltage Offset Correction: v_off_ini = 686.183 uV, v_off_fin = 700.771 uV 16:09:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.268 uVs 16:09:59 I1X Average and RMS of Measurements VT = -77.670 +- 4.237 uVs I1X = 15.534 +- 0.847 uTm 16:10:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:06 Integrated Voltage Measurement... 16:10:15 Voltage Offset Correction: v_off_ini = 711.094 uV, v_off_fin = 699.898 uV 16:10:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.090 uVs 16:10:15 Integrated Voltage Measurement... 16:10:24 Voltage Offset Correction: v_off_ini = 710.456 uV, v_off_fin = 717.009 uV 16:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.860 uVs 16:10:24 Integrated Voltage Measurement... 16:10:33 Voltage Offset Correction: v_off_ini = 690.023 uV, v_off_fin = 695.877 uV 16:10:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.446 uVs 16:10:33 Integrated Voltage Measurement... 16:10:42 Voltage Offset Correction: v_off_ini = 693.777 uV, v_off_fin = 713.041 uV 16:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.661 uVs 16:10:42 Integrated Voltage Measurement... 16:10:51 Voltage Offset Correction: v_off_ini = 710.878 uV, v_off_fin = 713.557 uV 16:10:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.716 uVs 16:10:51 Integrated Voltage Measurement... 16:11:00 Voltage Offset Correction: v_off_ini = 725.040 uV, v_off_fin = 723.967 uV 16:11:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.862 uVs 16:11:04 I1Y Average and RMS of Measurements VT = -194.106 +- 4.418 uVs I1Y = -38.821 +- 0.884 uTm 16:11:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:12 Integrated Voltage Measurement... 16:11:21 Voltage Offset Correction: v_off_ini = 722.138 uV, v_off_fin = 714.966 uV 16:11:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -74.415 uVs 16:11:21 Integrated Voltage Measurement... 16:11:30 Voltage Offset Correction: v_off_ini = 708.308 uV, v_off_fin = 710.118 uV 16:11:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.605 uVs 16:11:30 Integrated Voltage Measurement... 16:11:39 Voltage Offset Correction: v_off_ini = 709.163 uV, v_off_fin = 693.955 uV 16:11:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.955 uVs 16:11:39 Integrated Voltage Measurement... 16:11:48 Voltage Offset Correction: v_off_ini = 684.401 uV, v_off_fin = 707.159 uV 16:11:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.765 uVs 16:11:48 Integrated Voltage Measurement... 16:11:57 Voltage Offset Correction: v_off_ini = 713.709 uV, v_off_fin = 703.853 uV 16:11:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.398 uVs 16:11:57 Integrated Voltage Measurement... 16:12:06 Voltage Offset Correction: v_off_ini = 703.818 uV, v_off_fin = 699.394 uV 16:12:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.957 uVs 16:12:08 I2X Average and RMS of Measurements VT = -72.683 +- 4.160 uVs I2X = 6.687 +- 0.383 uTm^2 16:12:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:16 Integrated Voltage Measurement... 16:12:25 Voltage Offset Correction: v_off_ini = 697.071 uV, v_off_fin = 695.590 uV 16:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.134 uVs 16:12:25 Integrated Voltage Measurement... 16:12:34 Voltage Offset Correction: v_off_ini = 704.229 uV, v_off_fin = 699.574 uV 16:12:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.454 uVs 16:12:34 Integrated Voltage Measurement... 16:12:43 Voltage Offset Correction: v_off_ini = 702.802 uV, v_off_fin = 687.579 uV 16:12:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.965 uVs 16:12:43 Integrated Voltage Measurement... 16:12:52 Voltage Offset Correction: v_off_ini = 699.607 uV, v_off_fin = 687.956 uV 16:12:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.548 uVs 16:12:52 Integrated Voltage Measurement... 16:13:01 Voltage Offset Correction: v_off_ini = 690.464 uV, v_off_fin = 696.447 uV 16:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.670 uVs 16:13:01 Integrated Voltage Measurement... 16:13:10 Voltage Offset Correction: v_off_ini = 694.541 uV, v_off_fin = 695.846 uV 16:13:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.868 uVs 16:13:12 I2Y Average and RMS of Measurements VT = -292.940 +- 5.375 uVs I2Y = -26.950 +- 0.494 uTm^2 16:13:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:31 Integrated Voltage Measurement... 16:13:40 Voltage Offset Correction: v_off_ini = 698.574 uV, v_off_fin = 683.965 uV 16:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -68.268 uVs 16:13:40 Integrated Voltage Measurement... 16:13:49 Voltage Offset Correction: v_off_ini = 677.738 uV, v_off_fin = 696.367 uV 16:13:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.760 uVs 16:13:49 Integrated Voltage Measurement... 16:13:58 Voltage Offset Correction: v_off_ini = 698.573 uV, v_off_fin = 719.827 uV 16:13:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.692 uVs 16:13:58 Integrated Voltage Measurement... 16:14:07 Voltage Offset Correction: v_off_ini = 706.169 uV, v_off_fin = 712.603 uV 16:14:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 67.921 uVs 16:14:07 Integrated Voltage Measurement... 16:14:16 Voltage Offset Correction: v_off_ini = 705.885 uV, v_off_fin = 719.105 uV 16:14:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -82.673 uVs 16:14:16 Integrated Voltage Measurement... 16:14:25 Voltage Offset Correction: v_off_ini = 723.321 uV, v_off_fin = 719.512 uV 16:14:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.233 uVs 16:14:29 I1X Average and RMS of Measurements VT = -75.758 +- 13.355 uVs I1X = 15.151 +- 2.672 uTm 16:14:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:36 Integrated Voltage Measurement... 16:14:45 Voltage Offset Correction: v_off_ini = 725.904 uV, v_off_fin = 711.245 uV 16:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.949 uVs 16:14:45 Integrated Voltage Measurement... 16:14:54 Voltage Offset Correction: v_off_ini = 714.471 uV, v_off_fin = 724.199 uV 16:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.271 uVs 16:14:54 Integrated Voltage Measurement... 16:15:03 Voltage Offset Correction: v_off_ini = 718.212 uV, v_off_fin = 703.231 uV 16:15:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.086 uVs 16:15:03 Integrated Voltage Measurement... 16:15:12 Voltage Offset Correction: v_off_ini = 722.749 uV, v_off_fin = 740.280 uV 16:15:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.399 uVs 16:15:12 Integrated Voltage Measurement... 16:15:21 Voltage Offset Correction: v_off_ini = 723.526 uV, v_off_fin = 714.014 uV 16:15:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -207.809 uVs 16:15:21 Integrated Voltage Measurement... 16:15:30 Voltage Offset Correction: v_off_ini = 723.020 uV, v_off_fin = 727.014 uV 16:15:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.673 uVs 16:15:34 I1Y Average and RMS of Measurements VT = -203.031 +- 7.315 uVs I1Y = -40.602 +- 1.462 uTm 16:15:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:41 Integrated Voltage Measurement... 16:15:50 Voltage Offset Correction: v_off_ini = 721.745 uV, v_off_fin = 722.493 uV 16:15:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -80.274 uVs 16:15:51 Integrated Voltage Measurement... 16:16:00 Voltage Offset Correction: v_off_ini = 718.809 uV, v_off_fin = 737.711 uV 16:16:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 51.805 uVs 16:16:00 Integrated Voltage Measurement... 16:16:09 Voltage Offset Correction: v_off_ini = 718.517 uV, v_off_fin = 713.759 uV 16:16:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.090 uVs 16:16:09 Integrated Voltage Measurement... 16:16:18 Voltage Offset Correction: v_off_ini = 718.984 uV, v_off_fin = 736.017 uV 16:16:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.463 uVs 16:16:18 Integrated Voltage Measurement... 16:16:27 Voltage Offset Correction: v_off_ini = 723.801 uV, v_off_fin = 722.846 uV 16:16:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.398 uVs 16:16:27 Integrated Voltage Measurement... 16:16:36 Voltage Offset Correction: v_off_ini = 730.559 uV, v_off_fin = 731.461 uV 16:16:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 51.032 uVs 16:16:38 I2X Average and RMS of Measurements VT = -66.010 +- 0.638 uVs I2X = 6.073 +- 0.059 uTm^2 16:16:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:46 Integrated Voltage Measurement... 16:16:55 Voltage Offset Correction: v_off_ini = 738.990 uV, v_off_fin = 732.447 uV 16:16:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.123 uVs 16:16:55 Integrated Voltage Measurement... 16:17:04 Voltage Offset Correction: v_off_ini = 736.868 uV, v_off_fin = 717.661 uV 16:17:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.864 uVs 16:17:04 Integrated Voltage Measurement... 16:17:13 Voltage Offset Correction: v_off_ini = 721.597 uV, v_off_fin = 722.632 uV 16:17:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.895 uVs 16:17:13 Integrated Voltage Measurement... 16:17:22 Voltage Offset Correction: v_off_ini = 724.869 uV, v_off_fin = 721.944 uV 16:17:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.590 uVs 16:17:22 Integrated Voltage Measurement... 16:17:31 Voltage Offset Correction: v_off_ini = 718.058 uV, v_off_fin = 721.718 uV 16:17:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.650 uVs 16:17:31 Integrated Voltage Measurement... 16:17:40 Voltage Offset Correction: v_off_ini = 735.173 uV, v_off_fin = 721.687 uV 16:17:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.401 uVs 16:17:42 I2Y Average and RMS of Measurements VT = -291.420 +- 10.274 uVs I2Y = -26.811 +- 0.945 uTm^2 16:17:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm