SLAC Magnetic Measurements Date: 09-02-2025 Time: 11:35:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16340 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 11:36:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:05 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:36:07 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:36:09 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:36:10 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:36:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:36:59 Integrated Voltage Measurement... 11:37:08 Voltage Offset Correction: v_off_ini = 58.521 uV, v_off_fin = 62.987 uV 11:37:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.386 uVs 11:37:08 Integrated Voltage Measurement... 11:37:17 Voltage Offset Correction: v_off_ini = 58.094 uV, v_off_fin = 77.006 uV 11:37:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.895 uVs 11:37:17 Integrated Voltage Measurement... 11:37:26 Voltage Offset Correction: v_off_ini = 88.877 uV, v_off_fin = 79.154 uV 11:37:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.318 uVs 11:37:26 Integrated Voltage Measurement... 11:37:35 Voltage Offset Correction: v_off_ini = 77.958 uV, v_off_fin = 75.123 uV 11:37:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.228 uVs 11:37:35 Integrated Voltage Measurement... 11:37:44 Voltage Offset Correction: v_off_ini = 91.711 uV, v_off_fin = 78.306 uV 11:37:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.058 uVs 11:37:44 Integrated Voltage Measurement... 11:37:53 Voltage Offset Correction: v_off_ini = 82.366 uV, v_off_fin = 76.950 uV 11:37:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.102 uVs 11:37:57 I1X Average and RMS of Measurements VT = -93.998 +- 13.042 uVs I1X = 18.800 +- 2.608 uTm 11:38:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:38:04 Integrated Voltage Measurement... 11:38:13 Voltage Offset Correction: v_off_ini = 85.648 uV, v_off_fin = 63.162 uV 11:38:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -210.893 uVs 11:38:13 Integrated Voltage Measurement... 11:38:22 Voltage Offset Correction: v_off_ini = 88.605 uV, v_off_fin = 94.195 uV 11:38:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.772 uVs 11:38:22 Integrated Voltage Measurement... 11:38:31 Voltage Offset Correction: v_off_ini = 82.293 uV, v_off_fin = 78.366 uV 11:38:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -195.113 uVs 11:38:31 Integrated Voltage Measurement... 11:38:40 Voltage Offset Correction: v_off_ini = 82.092 uV, v_off_fin = 91.588 uV 11:38:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.009 uVs 11:38:40 Integrated Voltage Measurement... 11:38:49 Voltage Offset Correction: v_off_ini = 88.269 uV, v_off_fin = 85.182 uV 11:38:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.719 uVs 11:38:49 Integrated Voltage Measurement... 11:38:58 Voltage Offset Correction: v_off_ini = 94.363 uV, v_off_fin = 109.147 uV 11:38:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.102 uVs 11:39:02 I1Y Average and RMS of Measurements VT = -206.601 +- 4.195 uVs I1Y = -41.322 +- 0.839 uTm 11:39:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:39:10 Integrated Voltage Measurement... 11:39:19 Voltage Offset Correction: v_off_ini = 100.687 uV, v_off_fin = 98.591 uV 11:39:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -77.752 uVs 11:39:19 Integrated Voltage Measurement... 11:39:28 Voltage Offset Correction: v_off_ini = 94.817 uV, v_off_fin = 101.944 uV 11:39:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.875 uVs 11:39:28 Integrated Voltage Measurement... 11:39:37 Voltage Offset Correction: v_off_ini = 90.508 uV, v_off_fin = 87.141 uV 11:39:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.908 uVs 11:39:37 Integrated Voltage Measurement... 11:39:46 Voltage Offset Correction: v_off_ini = 97.393 uV, v_off_fin = 105.879 uV 11:39:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.667 uVs 11:39:46 Integrated Voltage Measurement... 11:39:55 Voltage Offset Correction: v_off_ini = 75.093 uV, v_off_fin = 87.903 uV 11:39:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.792 uVs 11:39:55 Integrated Voltage Measurement... 11:40:04 Voltage Offset Correction: v_off_ini = 94.948 uV, v_off_fin = 106.089 uV 11:40:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.388 uVs 11:40:07 I2X Average and RMS of Measurements VT = -71.564 +- 12.095 uVs I2X = 6.584 +- 1.113 uTm^2 11:40:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:40:15 Integrated Voltage Measurement... 11:40:24 Voltage Offset Correction: v_off_ini = 78.403 uV, v_off_fin = 88.955 uV 11:40:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.200 uVs 11:40:24 Integrated Voltage Measurement... 11:40:33 Voltage Offset Correction: v_off_ini = 95.652 uV, v_off_fin = 93.743 uV 11:40:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.437 uVs 11:40:33 Integrated Voltage Measurement... 11:40:42 Voltage Offset Correction: v_off_ini = 87.217 uV, v_off_fin = 99.562 uV 11:40:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.640 uVs 11:40:42 Integrated Voltage Measurement... 11:40:51 Voltage Offset Correction: v_off_ini = 101.428 uV, v_off_fin = 102.665 uV 11:40:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.260 uVs 11:40:51 Integrated Voltage Measurement... 11:41:00 Voltage Offset Correction: v_off_ini = 88.422 uV, v_off_fin = 83.602 uV 11:41:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.563 uVs 11:41:00 Integrated Voltage Measurement... 11:41:09 Voltage Offset Correction: v_off_ini = 88.987 uV, v_off_fin = 81.963 uV 11:41:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.001 uVs 11:41:11 I2Y Average and RMS of Measurements VT = -260.683 +- 7.284 uVs I2Y = -23.983 +- 0.670 uTm^2 11:41:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:41:20 Integrated Voltage Measurement... 11:41:29 Voltage Offset Correction: v_off_ini = 91.826 uV, v_off_fin = 82.449 uV 11:41:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.033 uVs 11:41:29 Integrated Voltage Measurement... 11:41:38 Voltage Offset Correction: v_off_ini = 90.693 uV, v_off_fin = 100.335 uV 11:41:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.717 uVs 11:41:38 Integrated Voltage Measurement... 11:41:47 Voltage Offset Correction: v_off_ini = 97.279 uV, v_off_fin = 89.985 uV 11:41:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.909 uVs 11:41:47 Integrated Voltage Measurement... 11:41:56 Voltage Offset Correction: v_off_ini = 92.326 uV, v_off_fin = 103.277 uV 11:41:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.905 uVs 11:41:56 Integrated Voltage Measurement... 11:42:05 Voltage Offset Correction: v_off_ini = 96.370 uV, v_off_fin = 99.413 uV 11:42:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.174 uVs 11:42:05 Integrated Voltage Measurement... 11:42:14 Voltage Offset Correction: v_off_ini = 98.265 uV, v_off_fin = 93.174 uV 11:42:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.125 uVs 11:42:18 I1X Average and RMS of Measurements VT = -87.477 +- 4.817 uVs I1X = 17.495 +- 0.963 uTm 11:42:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:42:25 Integrated Voltage Measurement... 11:42:34 Voltage Offset Correction: v_off_ini = 85.262 uV, v_off_fin = 70.646 uV 11:42:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.480 uVs 11:42:34 Integrated Voltage Measurement... 11:42:43 Voltage Offset Correction: v_off_ini = 82.396 uV, v_off_fin = 98.181 uV 11:42:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.578 uVs 11:42:43 Integrated Voltage Measurement... 11:42:52 Voltage Offset Correction: v_off_ini = 86.070 uV, v_off_fin = 76.196 uV 11:42:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.930 uVs 11:42:52 Integrated Voltage Measurement... 11:43:01 Voltage Offset Correction: v_off_ini = 88.952 uV, v_off_fin = 102.294 uV 11:43:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.668 uVs 11:43:01 Integrated Voltage Measurement... 11:43:10 Voltage Offset Correction: v_off_ini = 78.957 uV, v_off_fin = 79.679 uV 11:43:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.808 uVs 11:43:10 Integrated Voltage Measurement... 11:43:19 Voltage Offset Correction: v_off_ini = 85.330 uV, v_off_fin = 111.465 uV 11:43:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.277 uVs 11:43:23 I1Y Average and RMS of Measurements VT = -237.457 +- 1.711 uVs I1Y = -47.491 +- 0.342 uTm 11:43:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:43:31 Integrated Voltage Measurement... 11:43:40 Voltage Offset Correction: v_off_ini = 89.234 uV, v_off_fin = 73.104 uV 11:43:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.047 uVs 11:43:40 Integrated Voltage Measurement... 11:43:49 Voltage Offset Correction: v_off_ini = 82.562 uV, v_off_fin = 95.249 uV 11:43:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.608 uVs 11:43:49 Integrated Voltage Measurement... 11:43:58 Voltage Offset Correction: v_off_ini = 84.001 uV, v_off_fin = 72.543 uV 11:43:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.528 uVs 11:43:58 Integrated Voltage Measurement... 11:44:07 Voltage Offset Correction: v_off_ini = 79.563 uV, v_off_fin = 102.295 uV 11:44:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.061 uVs 11:44:07 Integrated Voltage Measurement... 11:44:16 Voltage Offset Correction: v_off_ini = 94.554 uV, v_off_fin = 90.819 uV 11:44:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.789 uVs 11:44:16 Integrated Voltage Measurement... 11:44:25 Voltage Offset Correction: v_off_ini = 97.747 uV, v_off_fin = 118.066 uV 11:44:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.834 uVs 11:44:28 I2X Average and RMS of Measurements VT = -66.145 +- 1.548 uVs I2X = 6.085 +- 0.142 uTm^2 11:44:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:44:36 Integrated Voltage Measurement... 11:44:45 Voltage Offset Correction: v_off_ini = 111.797 uV, v_off_fin = 105.228 uV 11:44:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.725 uVs 11:44:45 Integrated Voltage Measurement... 11:44:54 Voltage Offset Correction: v_off_ini = 106.263 uV, v_off_fin = 103.823 uV 11:44:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.667 uVs 11:44:54 Integrated Voltage Measurement... 11:45:03 Voltage Offset Correction: v_off_ini = 105.530 uV, v_off_fin = 94.714 uV 11:45:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.837 uVs 11:45:03 Integrated Voltage Measurement... 11:45:12 Voltage Offset Correction: v_off_ini = 89.972 uV, v_off_fin = 95.470 uV 11:45:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.160 uVs 11:45:12 Integrated Voltage Measurement... 11:45:21 Voltage Offset Correction: v_off_ini = 97.775 uV, v_off_fin = 99.651 uV 11:45:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.742 uVs 11:45:21 Integrated Voltage Measurement... 11:45:30 Voltage Offset Correction: v_off_ini = 93.754 uV, v_off_fin = 99.116 uV 11:45:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.816 uVs 11:45:32 I2Y Average and RMS of Measurements VT = -295.324 +- 4.867 uVs I2Y = -27.170 +- 0.448 uTm^2 11:45:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:41 Integrated Voltage Measurement... 11:45:50 Voltage Offset Correction: v_off_ini = 93.101 uV, v_off_fin = 93.514 uV 11:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.197 uVs 11:45:50 Integrated Voltage Measurement... 11:45:59 Voltage Offset Correction: v_off_ini = 100.308 uV, v_off_fin = 109.907 uV 11:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.939 uVs 11:45:59 Integrated Voltage Measurement... 11:46:08 Voltage Offset Correction: v_off_ini = 107.337 uV, v_off_fin = 94.355 uV 11:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.463 uVs 11:46:08 Integrated Voltage Measurement... 11:46:17 Voltage Offset Correction: v_off_ini = 79.788 uV, v_off_fin = 104.027 uV 11:46:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.235 uVs 11:46:17 Integrated Voltage Measurement... 11:46:26 Voltage Offset Correction: v_off_ini = 89.912 uV, v_off_fin = 90.263 uV 11:46:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.363 uVs 11:46:26 Integrated Voltage Measurement... 11:46:35 Voltage Offset Correction: v_off_ini = 81.892 uV, v_off_fin = 79.772 uV 11:46:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.645 uVs 11:46:39 I1X Average and RMS of Measurements VT = -94.807 +- 4.638 uVs I1X = 18.961 +- 0.928 uTm 11:46:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:46 Integrated Voltage Measurement... 11:46:55 Voltage Offset Correction: v_off_ini = 79.926 uV, v_off_fin = 77.733 uV 11:46:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.381 uVs 11:46:55 Integrated Voltage Measurement... 11:47:04 Voltage Offset Correction: v_off_ini = 100.264 uV, v_off_fin = 114.953 uV 11:47:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.422 uVs 11:47:04 Integrated Voltage Measurement... 11:47:13 Voltage Offset Correction: v_off_ini = 98.626 uV, v_off_fin = 79.348 uV 11:47:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.331 uVs 11:47:13 Integrated Voltage Measurement... 11:47:22 Voltage Offset Correction: v_off_ini = 84.058 uV, v_off_fin = 86.374 uV 11:47:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.621 uVs 11:47:22 Integrated Voltage Measurement... 11:47:31 Voltage Offset Correction: v_off_ini = 77.270 uV, v_off_fin = 77.926 uV 11:47:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.709 uVs 11:47:31 Integrated Voltage Measurement... 11:47:40 Voltage Offset Correction: v_off_ini = 85.388 uV, v_off_fin = 92.128 uV 11:47:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.651 uVs 11:47:45 I1Y Average and RMS of Measurements VT = -253.019 +- 4.900 uVs I1Y = -50.605 +- 0.979 uTm 11:47:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:52 Integrated Voltage Measurement... 11:48:01 Voltage Offset Correction: v_off_ini = 76.360 uV, v_off_fin = 58.130 uV 11:48:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.953 uVs 11:48:01 Integrated Voltage Measurement... 11:48:10 Voltage Offset Correction: v_off_ini = 63.781 uV, v_off_fin = 72.262 uV 11:48:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 54.101 uVs 11:48:10 Integrated Voltage Measurement... 11:48:19 Voltage Offset Correction: v_off_ini = 70.208 uV, v_off_fin = 59.034 uV 11:48:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.238 uVs 11:48:19 Integrated Voltage Measurement... 11:48:28 Voltage Offset Correction: v_off_ini = 68.301 uV, v_off_fin = 78.398 uV 11:48:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.260 uVs 11:48:28 Integrated Voltage Measurement... 11:48:37 Voltage Offset Correction: v_off_ini = 61.381 uV, v_off_fin = 61.156 uV 11:48:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.503 uVs 11:48:38 Integrated Voltage Measurement... 11:48:47 Voltage Offset Correction: v_off_ini = 72.144 uV, v_off_fin = 71.341 uV 11:48:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.926 uVs 11:48:49 I2X Average and RMS of Measurements VT = -62.663 +- 5.443 uVs I2X = 5.765 +- 0.501 uTm^2 11:48:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:57 Integrated Voltage Measurement... 11:49:06 Voltage Offset Correction: v_off_ini = 59.283 uV, v_off_fin = 58.633 uV 11:49:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.612 uVs 11:49:06 Integrated Voltage Measurement... 11:49:15 Voltage Offset Correction: v_off_ini = 65.087 uV, v_off_fin = 55.215 uV 11:49:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.968 uVs 11:49:15 Integrated Voltage Measurement... 11:49:24 Voltage Offset Correction: v_off_ini = 46.696 uV, v_off_fin = 45.614 uV 11:49:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.861 uVs 11:49:24 Integrated Voltage Measurement... 11:49:33 Voltage Offset Correction: v_off_ini = 52.628 uV, v_off_fin = 65.037 uV 11:49:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.532 uVs 11:49:33 Integrated Voltage Measurement... 11:49:42 Voltage Offset Correction: v_off_ini = 61.197 uV, v_off_fin = 58.760 uV 11:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.877 uVs 11:49:42 Integrated Voltage Measurement... 11:49:51 Voltage Offset Correction: v_off_ini = 64.990 uV, v_off_fin = 61.398 uV 11:49:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 321.577 uVs 11:49:53 I2Y Average and RMS of Measurements VT = -313.571 +- 5.363 uVs I2Y = -28.849 +- 0.494 uTm^2 11:49:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:50:02 Integrated Voltage Measurement... 11:50:11 Voltage Offset Correction: v_off_ini = 78.039 uV, v_off_fin = 57.565 uV 11:50:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.551 uVs 11:50:11 Integrated Voltage Measurement... 11:50:20 Voltage Offset Correction: v_off_ini = 68.661 uV, v_off_fin = 64.412 uV 11:50:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.722 uVs 11:50:20 Integrated Voltage Measurement... 11:50:29 Voltage Offset Correction: v_off_ini = 70.786 uV, v_off_fin = 59.384 uV 11:50:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.436 uVs 11:50:29 Integrated Voltage Measurement... 11:50:38 Voltage Offset Correction: v_off_ini = 66.462 uV, v_off_fin = 63.197 uV 11:50:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.137 uVs 11:50:38 Integrated Voltage Measurement... 11:50:47 Voltage Offset Correction: v_off_ini = 66.117 uV, v_off_fin = 54.301 uV 11:50:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.985 uVs 11:50:47 Integrated Voltage Measurement... 11:50:56 Voltage Offset Correction: v_off_ini = 56.882 uV, v_off_fin = 72.123 uV 11:50:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.659 uVs 11:51:01 I1X Average and RMS of Measurements VT = -92.081 +- 3.048 uVs I1X = 18.416 +- 0.610 uTm 11:51:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:51:07 Integrated Voltage Measurement... 11:51:16 Voltage Offset Correction: v_off_ini = 60.488 uV, v_off_fin = 50.433 uV 11:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -276.846 uVs 11:51:16 Integrated Voltage Measurement... 11:51:25 Voltage Offset Correction: v_off_ini = 64.613 uV, v_off_fin = 73.512 uV 11:51:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.531 uVs 11:51:25 Integrated Voltage Measurement... 11:51:34 Voltage Offset Correction: v_off_ini = 60.974 uV, v_off_fin = 45.453 uV 11:51:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.737 uVs 11:51:34 Integrated Voltage Measurement... 11:51:43 Voltage Offset Correction: v_off_ini = 61.968 uV, v_off_fin = 77.750 uV 11:51:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.581 uVs 11:51:43 Integrated Voltage Measurement... 11:51:52 Voltage Offset Correction: v_off_ini = 48.601 uV, v_off_fin = 33.202 uV 11:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.129 uVs 11:51:52 Integrated Voltage Measurement... 11:52:01 Voltage Offset Correction: v_off_ini = 59.925 uV, v_off_fin = 67.071 uV 11:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.745 uVs 11:52:06 I1Y Average and RMS of Measurements VT = -277.428 +- 2.597 uVs I1Y = -55.487 +- 0.520 uTm 11:52:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:52:14 Integrated Voltage Measurement... 11:52:23 Voltage Offset Correction: v_off_ini = 47.582 uV, v_off_fin = 44.046 uV 11:52:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.354 uVs 11:52:23 Integrated Voltage Measurement... 11:52:32 Voltage Offset Correction: v_off_ini = 56.368 uV, v_off_fin = 53.207 uV 11:52:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.753 uVs 11:52:32 Integrated Voltage Measurement... 11:52:41 Voltage Offset Correction: v_off_ini = 49.167 uV, v_off_fin = 55.979 uV 11:52:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.204 uVs 11:52:41 Integrated Voltage Measurement... 11:52:50 Voltage Offset Correction: v_off_ini = 51.395 uV, v_off_fin = 61.228 uV 11:52:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.081 uVs 11:52:50 Integrated Voltage Measurement... 11:52:59 Voltage Offset Correction: v_off_ini = 61.486 uV, v_off_fin = 46.937 uV 11:52:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.730 uVs 11:52:59 Integrated Voltage Measurement... 11:53:08 Voltage Offset Correction: v_off_ini = 34.962 uV, v_off_fin = 59.529 uV 11:53:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.676 uVs 11:53:10 I2X Average and RMS of Measurements VT = -71.966 +- 10.028 uVs I2X = 6.621 +- 0.923 uTm^2 11:53:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:53:18 Integrated Voltage Measurement... 11:53:27 Voltage Offset Correction: v_off_ini = 36.360 uV, v_off_fin = 54.765 uV 11:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.413 uVs 11:53:27 Integrated Voltage Measurement... 11:53:36 Voltage Offset Correction: v_off_ini = 53.114 uV, v_off_fin = 55.370 uV 11:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.120 uVs 11:53:36 Integrated Voltage Measurement... 11:53:45 Voltage Offset Correction: v_off_ini = 42.914 uV, v_off_fin = 52.322 uV 11:53:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.323 uVs 11:53:45 Integrated Voltage Measurement... 11:53:54 Voltage Offset Correction: v_off_ini = 60.208 uV, v_off_fin = 54.607 uV 11:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.400 uVs 11:53:54 Integrated Voltage Measurement... 11:54:03 Voltage Offset Correction: v_off_ini = 69.954 uV, v_off_fin = 55.558 uV 11:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.272 uVs 11:54:03 Integrated Voltage Measurement... 11:54:12 Voltage Offset Correction: v_off_ini = 53.209 uV, v_off_fin = 57.190 uV 11:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.959 uVs 11:54:15 I2Y Average and RMS of Measurements VT = -341.248 +- 4.391 uVs I2Y = -31.395 +- 0.404 uTm^2 11:54:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:54:24 Integrated Voltage Measurement... 11:54:32 Voltage Offset Correction: v_off_ini = 74.787 uV, v_off_fin = 73.519 uV 11:54:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.118 uVs 11:54:33 Integrated Voltage Measurement... 11:54:41 Voltage Offset Correction: v_off_ini = 72.176 uV, v_off_fin = 68.211 uV 11:54:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.672 uVs 11:54:42 Integrated Voltage Measurement... 11:54:51 Voltage Offset Correction: v_off_ini = 56.158 uV, v_off_fin = 50.017 uV 11:54:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.310 uVs 11:54:51 Integrated Voltage Measurement... 11:55:00 Voltage Offset Correction: v_off_ini = 67.483 uV, v_off_fin = 73.483 uV 11:55:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.276 uVs 11:55:00 Integrated Voltage Measurement... 11:55:09 Voltage Offset Correction: v_off_ini = 63.532 uV, v_off_fin = 57.325 uV 11:55:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.767 uVs 11:55:09 Integrated Voltage Measurement... 11:55:18 Voltage Offset Correction: v_off_ini = 68.605 uV, v_off_fin = 71.468 uV 11:55:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.682 uVs 11:55:22 I1X Average and RMS of Measurements VT = -101.971 +- 5.408 uVs I1X = 20.395 +- 1.081 uTm 11:55:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:55:29 Integrated Voltage Measurement... 11:55:38 Voltage Offset Correction: v_off_ini = 77.276 uV, v_off_fin = 66.594 uV 11:55:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -294.484 uVs 11:55:38 Integrated Voltage Measurement... 11:55:47 Voltage Offset Correction: v_off_ini = 73.648 uV, v_off_fin = 87.654 uV 11:55:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.705 uVs 11:55:47 Integrated Voltage Measurement... 11:55:56 Voltage Offset Correction: v_off_ini = 77.681 uV, v_off_fin = 73.830 uV 11:55:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -295.914 uVs 11:55:56 Integrated Voltage Measurement... 11:56:05 Voltage Offset Correction: v_off_ini = 83.158 uV, v_off_fin = 90.130 uV 11:56:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.367 uVs 11:56:05 Integrated Voltage Measurement... 11:56:14 Voltage Offset Correction: v_off_ini = 76.491 uV, v_off_fin = 70.691 uV 11:56:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.417 uVs 11:56:14 Integrated Voltage Measurement... 11:56:23 Voltage Offset Correction: v_off_ini = 84.349 uV, v_off_fin = 83.473 uV 11:56:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 298.026 uVs 11:56:27 I1Y Average and RMS of Measurements VT = -291.319 +- 4.073 uVs I1Y = -58.264 +- 0.815 uTm 11:56:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:56:35 Integrated Voltage Measurement... 11:56:44 Voltage Offset Correction: v_off_ini = 78.941 uV, v_off_fin = 68.853 uV 11:56:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -106.647 uVs 11:56:44 Integrated Voltage Measurement... 11:56:53 Voltage Offset Correction: v_off_ini = 80.459 uV, v_off_fin = 86.595 uV 11:56:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.137 uVs 11:56:53 Integrated Voltage Measurement... 11:57:02 Voltage Offset Correction: v_off_ini = 67.930 uV, v_off_fin = 62.148 uV 11:57:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.899 uVs 11:57:02 Integrated Voltage Measurement... 11:57:11 Voltage Offset Correction: v_off_ini = 64.243 uV, v_off_fin = 68.999 uV 11:57:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.188 uVs 11:57:11 Integrated Voltage Measurement... 11:57:20 Voltage Offset Correction: v_off_ini = 57.942 uV, v_off_fin = 52.731 uV 11:57:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.611 uVs 11:57:20 Integrated Voltage Measurement... 11:57:29 Voltage Offset Correction: v_off_ini = 66.444 uV, v_off_fin = 77.580 uV 11:57:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.512 uVs 11:57:31 I2X Average and RMS of Measurements VT = -85.665 +- 11.798 uVs I2X = 7.881 +- 1.085 uTm^2 11:57:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:57:39 Integrated Voltage Measurement... 11:57:48 Voltage Offset Correction: v_off_ini = 61.740 uV, v_off_fin = 64.170 uV 11:57:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.516 uVs 11:57:48 Integrated Voltage Measurement... 11:57:57 Voltage Offset Correction: v_off_ini = 67.974 uV, v_off_fin = 69.267 uV 11:57:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.871 uVs 11:57:57 Integrated Voltage Measurement... 11:58:06 Voltage Offset Correction: v_off_ini = 46.604 uV, v_off_fin = 45.632 uV 11:58:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.565 uVs 11:58:06 Integrated Voltage Measurement... 11:58:15 Voltage Offset Correction: v_off_ini = 58.340 uV, v_off_fin = 63.969 uV 11:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.376 uVs 11:58:15 Integrated Voltage Measurement... 11:58:24 Voltage Offset Correction: v_off_ini = 69.006 uV, v_off_fin = 70.113 uV 11:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.857 uVs 11:58:24 Integrated Voltage Measurement... 11:58:33 Voltage Offset Correction: v_off_ini = 63.353 uV, v_off_fin = 64.516 uV 11:58:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.526 uVs 11:58:35 I2Y Average and RMS of Measurements VT = -351.285 +- 6.410 uVs I2Y = -32.318 +- 0.590 uTm^2 11:58:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:58:47 Integrated Voltage Measurement... 11:58:56 Voltage Offset Correction: v_off_ini = 92.878 uV, v_off_fin = 94.918 uV 11:58:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -86.461 uVs 11:58:56 Integrated Voltage Measurement... 11:59:05 Voltage Offset Correction: v_off_ini = 92.435 uV, v_off_fin = 106.373 uV 11:59:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.177 uVs 11:59:05 Integrated Voltage Measurement... 11:59:14 Voltage Offset Correction: v_off_ini = 91.264 uV, v_off_fin = 87.310 uV 11:59:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -93.475 uVs 11:59:14 Integrated Voltage Measurement... 11:59:23 Voltage Offset Correction: v_off_ini = 101.870 uV, v_off_fin = 84.461 uV 11:59:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.083 uVs 11:59:24 Integrated Voltage Measurement... 11:59:32 Voltage Offset Correction: v_off_ini = 67.207 uV, v_off_fin = 70.497 uV 11:59:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.050 uVs 11:59:33 Integrated Voltage Measurement... 11:59:41 Voltage Offset Correction: v_off_ini = 92.402 uV, v_off_fin = 97.217 uV 11:59:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.810 uVs 11:59:46 I1X Average and RMS of Measurements VT = -93.009 +- 1.393 uVs I1X = 18.603 +- 0.279 uTm 11:59:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:59:53 Integrated Voltage Measurement... 12:00:01 Voltage Offset Correction: v_off_ini = 77.502 uV, v_off_fin = 71.591 uV 12:00:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.282 uVs 12:00:02 Integrated Voltage Measurement... 12:00:11 Voltage Offset Correction: v_off_ini = 54.083 uV, v_off_fin = 62.806 uV 12:00:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.721 uVs 12:00:11 Integrated Voltage Measurement... 12:00:20 Voltage Offset Correction: v_off_ini = 63.453 uV, v_off_fin = 58.816 uV 12:00:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.287 uVs 12:00:20 Integrated Voltage Measurement... 12:00:29 Voltage Offset Correction: v_off_ini = 69.547 uV, v_off_fin = 71.623 uV 12:00:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.046 uVs 12:00:29 Integrated Voltage Measurement... 12:00:38 Voltage Offset Correction: v_off_ini = 71.676 uV, v_off_fin = 53.070 uV 12:00:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.444 uVs 12:00:38 Integrated Voltage Measurement... 12:00:47 Voltage Offset Correction: v_off_ini = 63.964 uV, v_off_fin = 80.456 uV 12:00:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.632 uVs 12:00:51 I1Y Average and RMS of Measurements VT = -251.735 +- 3.051 uVs I1Y = -50.347 +- 0.610 uTm 12:00:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:00:56 Integrated Voltage Measurement... 12:01:05 Voltage Offset Correction: v_off_ini = 44.341 uV, v_off_fin = 61.113 uV 12:01:05 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -87.257 uVs 12:01:05 Integrated Voltage Measurement... 12:01:14 Voltage Offset Correction: v_off_ini = 55.154 uV, v_off_fin = 68.234 uV 12:01:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.303 uVs 12:01:14 Integrated Voltage Measurement... 12:01:23 Voltage Offset Correction: v_off_ini = 53.370 uV, v_off_fin = 28.844 uV 12:01:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.992 uVs 12:01:23 Integrated Voltage Measurement... 12:01:32 Voltage Offset Correction: v_off_ini = 32.462 uV, v_off_fin = 55.634 uV 12:01:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.880 uVs 12:01:32 Integrated Voltage Measurement... 12:01:41 Voltage Offset Correction: v_off_ini = 41.607 uV, v_off_fin = 34.039 uV 12:01:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.891 uVs 12:01:41 Integrated Voltage Measurement... 12:01:50 Voltage Offset Correction: v_off_ini = 35.674 uV, v_off_fin = 46.301 uV 12:01:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.291 uVs 12:01:53 I2X Average and RMS of Measurements VT = -89.769 +- 7.812 uVs I2X = 8.258 +- 0.719 uTm^2 12:01:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:01:58 Integrated Voltage Measurement... 12:02:07 Voltage Offset Correction: v_off_ini = 18.006 uV, v_off_fin = 26.728 uV 12:02:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.698 uVs 12:02:07 Integrated Voltage Measurement... 12:02:16 Voltage Offset Correction: v_off_ini = 36.129 uV, v_off_fin = 32.315 uV 12:02:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.179 uVs 12:02:16 Integrated Voltage Measurement... 12:02:25 Voltage Offset Correction: v_off_ini = 42.817 uV, v_off_fin = 38.765 uV 12:02:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.229 uVs 12:02:25 Integrated Voltage Measurement... 12:02:34 Voltage Offset Correction: v_off_ini = 28.895 uV, v_off_fin = 51.600 uV 12:02:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.635 uVs 12:02:34 Integrated Voltage Measurement... 12:02:43 Voltage Offset Correction: v_off_ini = 45.492 uV, v_off_fin = 40.998 uV 12:02:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.074 uVs 12:02:43 Integrated Voltage Measurement... 12:02:52 Voltage Offset Correction: v_off_ini = 44.681 uV, v_off_fin = 31.174 uV 12:02:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.595 uVs 12:02:54 I2Y Average and RMS of Measurements VT = -309.235 +- 9.033 uVs I2Y = -28.450 +- 0.831 uTm^2 12:02:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:03:03 Integrated Voltage Measurement... 12:03:12 Voltage Offset Correction: v_off_ini = 49.022 uV, v_off_fin = 45.990 uV 12:03:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -110.548 uVs 12:03:12 Integrated Voltage Measurement... 12:03:21 Voltage Offset Correction: v_off_ini = 57.783 uV, v_off_fin = 68.989 uV 12:03:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.631 uVs 12:03:21 Integrated Voltage Measurement... 12:03:30 Voltage Offset Correction: v_off_ini = 51.905 uV, v_off_fin = 50.004 uV 12:03:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.320 uVs 12:03:30 Integrated Voltage Measurement... 12:03:39 Voltage Offset Correction: v_off_ini = 53.390 uV, v_off_fin = 59.398 uV 12:03:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.315 uVs 12:03:39 Integrated Voltage Measurement... 12:03:48 Voltage Offset Correction: v_off_ini = 50.613 uV, v_off_fin = 48.293 uV 12:03:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.881 uVs 12:03:48 Integrated Voltage Measurement... 12:03:57 Voltage Offset Correction: v_off_ini = 45.701 uV, v_off_fin = 49.181 uV 12:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.348 uVs 12:04:01 I1X Average and RMS of Measurements VT = -96.507 +- 4.503 uVs I1X = 19.302 +- 0.900 uTm 12:04:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:04:08 Integrated Voltage Measurement... 12:04:17 Voltage Offset Correction: v_off_ini = 64.294 uV, v_off_fin = 44.936 uV 12:04:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.856 uVs 12:04:17 Integrated Voltage Measurement... 12:04:26 Voltage Offset Correction: v_off_ini = 62.219 uV, v_off_fin = 85.217 uV 12:04:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 251.016 uVs 12:04:26 Integrated Voltage Measurement... 12:04:35 Voltage Offset Correction: v_off_ini = 72.655 uV, v_off_fin = 56.149 uV 12:04:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.400 uVs 12:04:35 Integrated Voltage Measurement... 12:04:44 Voltage Offset Correction: v_off_ini = 64.168 uV, v_off_fin = 78.831 uV 12:04:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.800 uVs 12:04:44 Integrated Voltage Measurement... 12:04:53 Voltage Offset Correction: v_off_ini = 80.989 uV, v_off_fin = 59.153 uV 12:04:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.403 uVs 12:04:53 Integrated Voltage Measurement... 12:05:02 Voltage Offset Correction: v_off_ini = 70.688 uV, v_off_fin = 73.420 uV 12:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.450 uVs 12:05:06 I1Y Average and RMS of Measurements VT = -257.154 +- 7.232 uVs I1Y = -51.430 +- 1.447 uTm 12:05:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:05:11 Integrated Voltage Measurement... 12:05:20 Voltage Offset Correction: v_off_ini = 53.544 uV, v_off_fin = 48.953 uV 12:05:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.317 uVs 12:05:20 Integrated Voltage Measurement... 12:05:29 Voltage Offset Correction: v_off_ini = 52.027 uV, v_off_fin = 58.829 uV 12:05:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.870 uVs 12:05:29 Integrated Voltage Measurement... 12:05:38 Voltage Offset Correction: v_off_ini = 54.865 uV, v_off_fin = 55.244 uV 12:05:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.220 uVs 12:05:38 Integrated Voltage Measurement... 12:05:47 Voltage Offset Correction: v_off_ini = 52.521 uV, v_off_fin = 84.224 uV 12:05:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.530 uVs 12:05:47 Integrated Voltage Measurement... 12:05:56 Voltage Offset Correction: v_off_ini = 79.250 uV, v_off_fin = 74.233 uV 12:05:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.653 uVs 12:05:56 Integrated Voltage Measurement... 12:06:05 Voltage Offset Correction: v_off_ini = 75.330 uV, v_off_fin = 78.563 uV 12:06:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.581 uVs 12:06:08 I2X Average and RMS of Measurements VT = -81.195 +- 12.300 uVs I2X = 7.470 +- 1.132 uTm^2 12:06:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:06:13 Integrated Voltage Measurement... 12:06:22 Voltage Offset Correction: v_off_ini = 44.730 uV, v_off_fin = 60.008 uV 12:06:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.691 uVs 12:06:22 Integrated Voltage Measurement... 12:06:31 Voltage Offset Correction: v_off_ini = 51.363 uV, v_off_fin = 55.193 uV 12:06:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.745 uVs 12:06:31 Integrated Voltage Measurement... 12:06:40 Voltage Offset Correction: v_off_ini = 47.725 uV, v_off_fin = 42.744 uV 12:06:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.172 uVs 12:06:40 Integrated Voltage Measurement... 12:06:49 Voltage Offset Correction: v_off_ini = 50.124 uV, v_off_fin = 55.355 uV 12:06:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.980 uVs 12:06:49 Integrated Voltage Measurement... 12:06:58 Voltage Offset Correction: v_off_ini = 43.477 uV, v_off_fin = 43.817 uV 12:06:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.982 uVs 12:06:58 Integrated Voltage Measurement... 12:07:07 Voltage Offset Correction: v_off_ini = 56.212 uV, v_off_fin = 41.845 uV 12:07:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.215 uVs 12:07:10 I2Y Average and RMS of Measurements VT = -310.464 +- 5.957 uVs I2Y = -28.563 +- 0.548 uTm^2 12:07:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:18 Integrated Voltage Measurement... 12:07:27 Voltage Offset Correction: v_off_ini = 48.261 uV, v_off_fin = 47.168 uV 12:07:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -95.538 uVs 12:07:27 Integrated Voltage Measurement... 12:07:36 Voltage Offset Correction: v_off_ini = 52.007 uV, v_off_fin = 59.252 uV 12:07:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.071 uVs 12:07:36 Integrated Voltage Measurement... 12:07:45 Voltage Offset Correction: v_off_ini = 50.757 uV, v_off_fin = 60.853 uV 12:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.912 uVs 12:07:45 Integrated Voltage Measurement... 12:07:54 Voltage Offset Correction: v_off_ini = 64.309 uV, v_off_fin = 71.248 uV 12:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.445 uVs 12:07:54 Integrated Voltage Measurement... 12:08:03 Voltage Offset Correction: v_off_ini = 64.687 uV, v_off_fin = 64.345 uV 12:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.510 uVs 12:08:03 Integrated Voltage Measurement... 12:08:12 Voltage Offset Correction: v_off_ini = 55.875 uV, v_off_fin = 66.182 uV 12:08:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.708 uVs 12:08:16 I1X Average and RMS of Measurements VT = -88.697 +- 1.111 uVs I1X = 17.740 +- 0.223 uTm 12:08:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:23 Integrated Voltage Measurement... 12:08:32 Voltage Offset Correction: v_off_ini = 77.157 uV, v_off_fin = 69.641 uV 12:08:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.906 uVs 12:08:32 Integrated Voltage Measurement... 12:08:41 Voltage Offset Correction: v_off_ini = 80.837 uV, v_off_fin = 81.373 uV 12:08:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.507 uVs 12:08:41 Integrated Voltage Measurement... 12:08:50 Voltage Offset Correction: v_off_ini = 73.566 uV, v_off_fin = 57.433 uV 12:08:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.187 uVs 12:08:50 Integrated Voltage Measurement... 12:08:59 Voltage Offset Correction: v_off_ini = 69.688 uV, v_off_fin = 76.430 uV 12:08:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.216 uVs 12:08:59 Integrated Voltage Measurement... 12:09:08 Voltage Offset Correction: v_off_ini = 65.838 uV, v_off_fin = 59.361 uV 12:09:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.647 uVs 12:09:08 Integrated Voltage Measurement... 12:09:17 Voltage Offset Correction: v_off_ini = 64.757 uV, v_off_fin = 81.691 uV 12:09:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.524 uVs 12:09:21 I1Y Average and RMS of Measurements VT = -242.331 +- 4.904 uVs I1Y = -48.466 +- 0.981 uTm 12:09:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:26 Integrated Voltage Measurement... 12:09:35 Voltage Offset Correction: v_off_ini = 63.073 uV, v_off_fin = 56.009 uV 12:09:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -75.901 uVs 12:09:35 Integrated Voltage Measurement... 12:09:44 Voltage Offset Correction: v_off_ini = 53.786 uV, v_off_fin = 72.834 uV 12:09:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.132 uVs 12:09:44 Integrated Voltage Measurement... 12:09:53 Voltage Offset Correction: v_off_ini = 75.470 uV, v_off_fin = 56.663 uV 12:09:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.778 uVs 12:09:53 Integrated Voltage Measurement... 12:10:02 Voltage Offset Correction: v_off_ini = 59.855 uV, v_off_fin = 68.065 uV 12:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.030 uVs 12:10:02 Integrated Voltage Measurement... 12:10:11 Voltage Offset Correction: v_off_ini = 61.541 uV, v_off_fin = 59.258 uV 12:10:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.445 uVs 12:10:11 Integrated Voltage Measurement... 12:10:20 Voltage Offset Correction: v_off_ini = 77.351 uV, v_off_fin = 81.637 uV 12:10:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.997 uVs 12:10:23 I2X Average and RMS of Measurements VT = -73.214 +- 6.482 uVs I2X = 6.736 +- 0.596 uTm^2 12:10:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:28 Integrated Voltage Measurement... 12:10:37 Voltage Offset Correction: v_off_ini = 78.252 uV, v_off_fin = 81.859 uV 12:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.153 uVs 12:10:37 Integrated Voltage Measurement... 12:10:46 Voltage Offset Correction: v_off_ini = 84.248 uV, v_off_fin = 85.942 uV 12:10:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.318 uVs 12:10:46 Integrated Voltage Measurement... 12:10:55 Voltage Offset Correction: v_off_ini = 83.774 uV, v_off_fin = 72.199 uV 12:10:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -330.861 uVs 12:10:55 Integrated Voltage Measurement... 12:11:04 Voltage Offset Correction: v_off_ini = 67.420 uV, v_off_fin = 85.877 uV 12:11:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.977 uVs 12:11:04 Integrated Voltage Measurement... 12:11:13 Voltage Offset Correction: v_off_ini = 89.300 uV, v_off_fin = 83.898 uV 12:11:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.986 uVs 12:11:13 Integrated Voltage Measurement... 12:11:22 Voltage Offset Correction: v_off_ini = 76.495 uV, v_off_fin = 77.082 uV 12:11:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.802 uVs 12:11:25 I2Y Average and RMS of Measurements VT = -318.683 +- 16.379 uVs I2Y = -29.319 +- 1.507 uTm^2 12:11:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:11:33 Integrated Voltage Measurement... 12:11:42 Voltage Offset Correction: v_off_ini = 75.978 uV, v_off_fin = 79.585 uV 12:11:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.406 uVs 12:11:42 Integrated Voltage Measurement... 12:11:51 Voltage Offset Correction: v_off_ini = 87.713 uV, v_off_fin = 72.623 uV 12:11:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.007 uVs 12:11:51 Integrated Voltage Measurement... 12:12:00 Voltage Offset Correction: v_off_ini = 85.184 uV, v_off_fin = 90.144 uV 12:12:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.181 uVs 12:12:00 Integrated Voltage Measurement... 12:12:09 Voltage Offset Correction: v_off_ini = 100.585 uV, v_off_fin = 87.243 uV 12:12:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.451 uVs 12:12:09 Integrated Voltage Measurement... 12:12:18 Voltage Offset Correction: v_off_ini = 106.746 uV, v_off_fin = 92.431 uV 12:12:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.036 uVs 12:12:18 Integrated Voltage Measurement... 12:12:27 Voltage Offset Correction: v_off_ini = 107.850 uV, v_off_fin = 116.168 uV 12:12:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.461 uVs 12:12:31 I1X Average and RMS of Measurements VT = -71.090 +- 5.283 uVs I1X = 14.218 +- 1.057 uTm 12:12:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:12:38 Integrated Voltage Measurement... 12:12:47 Voltage Offset Correction: v_off_ini = 93.674 uV, v_off_fin = 76.675 uV 12:12:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -255.872 uVs 12:12:47 Integrated Voltage Measurement... 12:12:56 Voltage Offset Correction: v_off_ini = 89.184 uV, v_off_fin = 96.768 uV 12:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.228 uVs 12:12:56 Integrated Voltage Measurement... 12:13:05 Voltage Offset Correction: v_off_ini = 85.083 uV, v_off_fin = 77.847 uV 12:13:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.148 uVs 12:13:05 Integrated Voltage Measurement... 12:13:14 Voltage Offset Correction: v_off_ini = 85.354 uV, v_off_fin = 85.354 uV 12:13:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.128 uVs 12:13:14 Integrated Voltage Measurement... 12:13:23 Voltage Offset Correction: v_off_ini = 85.323 uV, v_off_fin = 71.838 uV 12:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.036 uVs 12:13:23 Integrated Voltage Measurement... 12:13:32 Voltage Offset Correction: v_off_ini = 83.563 uV, v_off_fin = 95.832 uV 12:13:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.755 uVs 12:13:36 I1Y Average and RMS of Measurements VT = -250.361 +- 6.050 uVs I1Y = -50.074 +- 1.212 uTm 12:13:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:13:41 Integrated Voltage Measurement... 12:13:50 Voltage Offset Correction: v_off_ini = 90.397 uV, v_off_fin = 84.642 uV 12:13:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -49.504 uVs 12:13:50 Integrated Voltage Measurement... 12:13:59 Voltage Offset Correction: v_off_ini = 86.114 uV, v_off_fin = 82.358 uV 12:13:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 56.408 uVs 12:14:00 Integrated Voltage Measurement... 12:14:08 Voltage Offset Correction: v_off_ini = 72.876 uV, v_off_fin = 71.160 uV 12:14:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.052 uVs 12:14:09 Integrated Voltage Measurement... 12:14:18 Voltage Offset Correction: v_off_ini = 77.940 uV, v_off_fin = 91.356 uV 12:14:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.346 uVs 12:14:18 Integrated Voltage Measurement... 12:14:27 Voltage Offset Correction: v_off_ini = 85.469 uV, v_off_fin = 81.067 uV 12:14:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.579 uVs 12:14:27 Integrated Voltage Measurement... 12:14:36 Voltage Offset Correction: v_off_ini = 95.747 uV, v_off_fin = 103.767 uV 12:14:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.302 uVs 12:14:38 I2X Average and RMS of Measurements VT = -54.698 +- 1.335 uVs I2X = 5.032 +- 0.123 uTm^2 12:14:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:14:43 Integrated Voltage Measurement... 12:14:52 Voltage Offset Correction: v_off_ini = 97.950 uV, v_off_fin = 93.155 uV 12:14:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.959 uVs 12:14:52 Integrated Voltage Measurement... 12:15:01 Voltage Offset Correction: v_off_ini = 87.933 uV, v_off_fin = 89.131 uV 12:15:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.848 uVs 12:15:01 Integrated Voltage Measurement... 12:15:10 Voltage Offset Correction: v_off_ini = 84.112 uV, v_off_fin = 93.134 uV 12:15:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.347 uVs 12:15:10 Integrated Voltage Measurement... 12:15:19 Voltage Offset Correction: v_off_ini = 84.230 uV, v_off_fin = 80.931 uV 12:15:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.884 uVs 12:15:19 Integrated Voltage Measurement... 12:15:28 Voltage Offset Correction: v_off_ini = 90.971 uV, v_off_fin = 82.425 uV 12:15:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.059 uVs 12:15:28 Integrated Voltage Measurement... 12:15:37 Voltage Offset Correction: v_off_ini = 93.424 uV, v_off_fin = 90.715 uV 12:15:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.114 uVs 12:15:40 I2Y Average and RMS of Measurements VT = -306.368 +- 4.990 uVs I2Y = -28.186 +- 0.459 uTm^2 12:15:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:15:48 Integrated Voltage Measurement... 12:15:57 Voltage Offset Correction: v_off_ini = 76.206 uV, v_off_fin = 85.480 uV 12:15:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.162 uVs 12:15:57 Integrated Voltage Measurement... 12:16:06 Voltage Offset Correction: v_off_ini = 92.211 uV, v_off_fin = 87.738 uV 12:16:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 53.442 uVs 12:16:06 Integrated Voltage Measurement... 12:16:15 Voltage Offset Correction: v_off_ini = 90.532 uV, v_off_fin = 91.091 uV 12:16:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.200 uVs 12:16:15 Integrated Voltage Measurement... 12:16:24 Voltage Offset Correction: v_off_ini = 97.635 uV, v_off_fin = 99.865 uV 12:16:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.424 uVs 12:16:24 Integrated Voltage Measurement... 12:16:33 Voltage Offset Correction: v_off_ini = 80.678 uV, v_off_fin = 84.973 uV 12:16:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.542 uVs 12:16:33 Integrated Voltage Measurement... 12:16:42 Voltage Offset Correction: v_off_ini = 87.052 uV, v_off_fin = 98.132 uV 12:16:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.029 uVs 12:16:46 I1X Average and RMS of Measurements VT = -51.966 +- 4.487 uVs I1X = 10.394 +- 0.897 uTm 12:16:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:16:53 Integrated Voltage Measurement... 12:17:02 Voltage Offset Correction: v_off_ini = 84.724 uV, v_off_fin = 83.358 uV 12:17:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -247.257 uVs 12:17:02 Integrated Voltage Measurement... 12:17:11 Voltage Offset Correction: v_off_ini = 107.900 uV, v_off_fin = 113.714 uV 12:17:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.963 uVs 12:17:11 Integrated Voltage Measurement... 12:17:20 Voltage Offset Correction: v_off_ini = 99.774 uV, v_off_fin = 77.691 uV 12:17:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.042 uVs 12:17:20 Integrated Voltage Measurement... 12:17:29 Voltage Offset Correction: v_off_ini = 97.140 uV, v_off_fin = 108.108 uV 12:17:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.310 uVs 12:17:29 Integrated Voltage Measurement... 12:17:38 Voltage Offset Correction: v_off_ini = 93.626 uV, v_off_fin = 73.808 uV 12:17:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.195 uVs 12:17:38 Integrated Voltage Measurement... 12:17:47 Voltage Offset Correction: v_off_ini = 85.857 uV, v_off_fin = 94.726 uV 12:17:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.290 uVs 12:17:51 I1Y Average and RMS of Measurements VT = -246.509 +- 2.739 uVs I1Y = -49.304 +- 0.549 uTm 12:17:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:17:57 Integrated Voltage Measurement... 12:18:06 Voltage Offset Correction: v_off_ini = 103.266 uV, v_off_fin = 104.409 uV 12:18:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.570 uVs 12:18:06 Integrated Voltage Measurement... 12:18:15 Voltage Offset Correction: v_off_ini = 105.871 uV, v_off_fin = 111.097 uV 12:18:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.471 uVs 12:18:15 Integrated Voltage Measurement... 12:18:24 Voltage Offset Correction: v_off_ini = 114.443 uV, v_off_fin = 105.006 uV 12:18:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.873 uVs 12:18:24 Integrated Voltage Measurement... 12:18:33 Voltage Offset Correction: v_off_ini = 112.473 uV, v_off_fin = 119.400 uV 12:18:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.974 uVs 12:18:33 Integrated Voltage Measurement... 12:18:42 Voltage Offset Correction: v_off_ini = 96.904 uV, v_off_fin = 94.006 uV 12:18:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.786 uVs 12:18:42 Integrated Voltage Measurement... 12:18:51 Voltage Offset Correction: v_off_ini = 104.496 uV, v_off_fin = 114.436 uV 12:18:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.925 uVs 12:18:53 I2X Average and RMS of Measurements VT = -40.100 +- 2.945 uVs I2X = 3.689 +- 0.271 uTm^2 12:18:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:18:58 Integrated Voltage Measurement... 12:19:07 Voltage Offset Correction: v_off_ini = 104.019 uV, v_off_fin = 113.242 uV 12:19:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.944 uVs 12:19:07 Integrated Voltage Measurement... 12:19:16 Voltage Offset Correction: v_off_ini = 118.161 uV, v_off_fin = 118.858 uV 12:19:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.694 uVs 12:19:16 Integrated Voltage Measurement... 12:19:25 Voltage Offset Correction: v_off_ini = 103.896 uV, v_off_fin = 114.959 uV 12:19:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.360 uVs 12:19:25 Integrated Voltage Measurement... 12:19:34 Voltage Offset Correction: v_off_ini = 129.058 uV, v_off_fin = 123.268 uV 12:19:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.149 uVs 12:19:35 Integrated Voltage Measurement... 12:19:44 Voltage Offset Correction: v_off_ini = 118.686 uV, v_off_fin = 119.576 uV 12:19:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.908 uVs 12:19:44 Integrated Voltage Measurement... 12:19:53 Voltage Offset Correction: v_off_ini = 113.352 uV, v_off_fin = 119.374 uV 12:19:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.142 uVs 12:19:55 I2Y Average and RMS of Measurements VT = -310.866 +- 7.459 uVs I2Y = -28.600 +- 0.686 uTm^2 12:20:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:20:15 Integrated Voltage Measurement... 12:20:24 Voltage Offset Correction: v_off_ini = 114.496 uV, v_off_fin = 112.004 uV 12:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.510 uVs 12:20:24 Integrated Voltage Measurement... 12:20:33 Voltage Offset Correction: v_off_ini = 115.583 uV, v_off_fin = 112.153 uV 12:20:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.590 uVs 12:20:33 Integrated Voltage Measurement... 12:20:42 Voltage Offset Correction: v_off_ini = 98.141 uV, v_off_fin = 103.061 uV 12:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.541 uVs 12:20:42 Integrated Voltage Measurement... 12:20:51 Voltage Offset Correction: v_off_ini = 109.636 uV, v_off_fin = 100.618 uV 12:20:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.625 uVs 12:20:51 Integrated Voltage Measurement... 12:21:00 Voltage Offset Correction: v_off_ini = 107.167 uV, v_off_fin = 94.188 uV 12:21:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.987 uVs 12:21:00 Integrated Voltage Measurement... 12:21:09 Voltage Offset Correction: v_off_ini = 89.965 uV, v_off_fin = 106.324 uV 12:21:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.665 uVs 12:21:13 I1X Average and RMS of Measurements VT = -99.320 +- 8.493 uVs I1X = 19.864 +- 1.699 uTm 12:21:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:21:20 Integrated Voltage Measurement... 12:21:29 Voltage Offset Correction: v_off_ini = 98.873 uV, v_off_fin = 99.333 uV 12:21:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.114 uVs 12:21:29 Integrated Voltage Measurement... 12:21:38 Voltage Offset Correction: v_off_ini = 110.872 uV, v_off_fin = 131.584 uV 12:21:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.701 uVs 12:21:38 Integrated Voltage Measurement... 12:21:47 Voltage Offset Correction: v_off_ini = 93.906 uV, v_off_fin = 80.482 uV 12:21:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.813 uVs 12:21:47 Integrated Voltage Measurement... 12:21:56 Voltage Offset Correction: v_off_ini = 96.470 uV, v_off_fin = 102.364 uV 12:21:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.613 uVs 12:21:56 Integrated Voltage Measurement... 12:22:05 Voltage Offset Correction: v_off_ini = 96.254 uV, v_off_fin = 88.199 uV 12:22:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.513 uVs 12:22:05 Integrated Voltage Measurement... 12:22:14 Voltage Offset Correction: v_off_ini = 95.304 uV, v_off_fin = 94.981 uV 12:22:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.864 uVs 12:22:18 I1Y Average and RMS of Measurements VT = -207.436 +- 1.361 uVs I1Y = -41.487 +- 0.272 uTm 12:22:23 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:22:26 Integrated Voltage Measurement... 12:22:35 Voltage Offset Correction: v_off_ini = 99.566 uV, v_off_fin = 89.798 uV 12:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.129 uVs 12:22:35 Integrated Voltage Measurement... 12:22:44 Voltage Offset Correction: v_off_ini = 84.125 uV, v_off_fin = 97.737 uV 12:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.914 uVs 12:22:44 Integrated Voltage Measurement... 12:22:53 Voltage Offset Correction: v_off_ini = 99.090 uV, v_off_fin = 79.305 uV 12:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.676 uVs 12:22:53 Integrated Voltage Measurement... 12:23:02 Voltage Offset Correction: v_off_ini = 79.950 uV, v_off_fin = 108.752 uV 12:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.848 uVs 12:23:02 Integrated Voltage Measurement... 12:23:11 Voltage Offset Correction: v_off_ini = 97.168 uV, v_off_fin = 89.280 uV 12:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.819 uVs 12:23:11 Integrated Voltage Measurement... 12:23:20 Voltage Offset Correction: v_off_ini = 101.320 uV, v_off_fin = 105.313 uV 12:23:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.139 uVs 12:23:23 I2X Average and RMS of Measurements VT = -84.254 +- 5.165 uVs I2X = 7.751 +- 0.475 uTm^2 12:23:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:23:30 Integrated Voltage Measurement... 12:23:39 Voltage Offset Correction: v_off_ini = 92.701 uV, v_off_fin = 89.109 uV 12:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.943 uVs 12:23:40 Integrated Voltage Measurement... 12:23:48 Voltage Offset Correction: v_off_ini = 104.607 uV, v_off_fin = 91.646 uV 12:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.027 uVs 12:23:49 Integrated Voltage Measurement... 12:23:58 Voltage Offset Correction: v_off_ini = 88.140 uV, v_off_fin = 80.948 uV 12:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.069 uVs 12:23:58 Integrated Voltage Measurement... 12:24:07 Voltage Offset Correction: v_off_ini = 95.678 uV, v_off_fin = 73.814 uV 12:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.040 uVs 12:24:07 Integrated Voltage Measurement... 12:24:16 Voltage Offset Correction: v_off_ini = 83.771 uV, v_off_fin = 85.217 uV 12:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.032 uVs 12:24:16 Integrated Voltage Measurement... 12:24:25 Voltage Offset Correction: v_off_ini = 94.946 uV, v_off_fin = 96.184 uV 12:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.651 uVs 12:24:27 I2Y Average and RMS of Measurements VT = -261.627 +- 4.295 uVs I2Y = -24.070 +- 0.395 uTm^2 12:24:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:24:36 Integrated Voltage Measurement... 12:24:45 Voltage Offset Correction: v_off_ini = 80.208 uV, v_off_fin = 82.430 uV 12:24:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.454 uVs 12:24:45 Integrated Voltage Measurement... 12:24:54 Voltage Offset Correction: v_off_ini = 66.973 uV, v_off_fin = 78.423 uV 12:24:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.561 uVs 12:24:54 Integrated Voltage Measurement... 12:25:03 Voltage Offset Correction: v_off_ini = 83.129 uV, v_off_fin = 67.539 uV 12:25:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.986 uVs 12:25:03 Integrated Voltage Measurement... 12:25:12 Voltage Offset Correction: v_off_ini = 68.370 uV, v_off_fin = 65.521 uV 12:25:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.248 uVs 12:25:12 Integrated Voltage Measurement... 12:25:21 Voltage Offset Correction: v_off_ini = 69.903 uV, v_off_fin = 63.793 uV 12:25:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.018 uVs 12:25:21 Integrated Voltage Measurement... 12:25:30 Voltage Offset Correction: v_off_ini = 79.457 uV, v_off_fin = 59.166 uV 12:25:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.114 uVs 12:25:34 I1X Average and RMS of Measurements VT = -100.397 +- 3.439 uVs I1X = 20.079 +- 0.688 uTm 12:25:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:25:41 Integrated Voltage Measurement... 12:25:50 Voltage Offset Correction: v_off_ini = 67.907 uV, v_off_fin = 55.764 uV 12:25:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.400 uVs 12:25:50 Integrated Voltage Measurement... 12:25:59 Voltage Offset Correction: v_off_ini = 60.667 uV, v_off_fin = 64.460 uV 12:25:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.391 uVs 12:25:59 Integrated Voltage Measurement... 12:26:08 Voltage Offset Correction: v_off_ini = 66.876 uV, v_off_fin = 52.852 uV 12:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.946 uVs 12:26:08 Integrated Voltage Measurement... 12:26:17 Voltage Offset Correction: v_off_ini = 66.550 uV, v_off_fin = 68.890 uV 12:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.723 uVs 12:26:17 Integrated Voltage Measurement... 12:26:26 Voltage Offset Correction: v_off_ini = 67.428 uV, v_off_fin = 54.379 uV 12:26:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.900 uVs 12:26:26 Integrated Voltage Measurement... 12:26:35 Voltage Offset Correction: v_off_ini = 69.957 uV, v_off_fin = 85.266 uV 12:26:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.743 uVs 12:26:39 I1Y Average and RMS of Measurements VT = -240.351 +- 5.385 uVs I1Y = -48.070 +- 1.077 uTm 12:26:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:26:47 Integrated Voltage Measurement... 12:26:56 Voltage Offset Correction: v_off_ini = 61.890 uV, v_off_fin = 49.010 uV 12:26:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.880 uVs 12:26:56 Integrated Voltage Measurement... 12:27:05 Voltage Offset Correction: v_off_ini = 58.820 uV, v_off_fin = 69.140 uV 12:27:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.015 uVs 12:27:05 Integrated Voltage Measurement... 12:27:14 Voltage Offset Correction: v_off_ini = 68.268 uV, v_off_fin = 65.269 uV 12:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.421 uVs 12:27:14 Integrated Voltage Measurement... 12:27:23 Voltage Offset Correction: v_off_ini = 72.824 uV, v_off_fin = 82.514 uV 12:27:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.311 uVs 12:27:23 Integrated Voltage Measurement... 12:27:32 Voltage Offset Correction: v_off_ini = 79.864 uV, v_off_fin = 68.615 uV 12:27:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.062 uVs 12:27:32 Integrated Voltage Measurement... 12:27:41 Voltage Offset Correction: v_off_ini = 90.330 uV, v_off_fin = 101.180 uV 12:27:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.041 uVs 12:27:44 I2X Average and RMS of Measurements VT = -87.955 +- 4.321 uVs I2X = 8.092 +- 0.397 uTm^2 12:27:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:27:51 Integrated Voltage Measurement... 12:28:00 Voltage Offset Correction: v_off_ini = 89.213 uV, v_off_fin = 80.626 uV 12:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.349 uVs 12:28:01 Integrated Voltage Measurement... 12:28:09 Voltage Offset Correction: v_off_ini = 89.176 uV, v_off_fin = 99.596 uV 12:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.011 uVs 12:28:10 Integrated Voltage Measurement... 12:28:19 Voltage Offset Correction: v_off_ini = 93.642 uV, v_off_fin = 86.293 uV 12:28:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -287.106 uVs 12:28:19 Integrated Voltage Measurement... 12:28:28 Voltage Offset Correction: v_off_ini = 72.969 uV, v_off_fin = 88.945 uV 12:28:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.556 uVs 12:28:28 Integrated Voltage Measurement... 12:28:37 Voltage Offset Correction: v_off_ini = 96.798 uV, v_off_fin = 89.624 uV 12:28:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.304 uVs 12:28:37 Integrated Voltage Measurement... 12:28:46 Voltage Offset Correction: v_off_ini = 82.192 uV, v_off_fin = 90.708 uV 12:28:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.943 uVs 12:28:48 I2Y Average and RMS of Measurements VT = -290.045 +- 1.018 uVs I2Y = -26.685 +- 0.094 uTm^2 12:28:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:57 Integrated Voltage Measurement... 12:29:06 Voltage Offset Correction: v_off_ini = 84.540 uV, v_off_fin = 65.997 uV 12:29:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.608 uVs 12:29:06 Integrated Voltage Measurement... 12:29:15 Voltage Offset Correction: v_off_ini = 65.875 uV, v_off_fin = 94.520 uV 12:29:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.829 uVs 12:29:15 Integrated Voltage Measurement... 12:29:24 Voltage Offset Correction: v_off_ini = 80.283 uV, v_off_fin = 85.509 uV 12:29:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.225 uVs 12:29:24 Integrated Voltage Measurement... 12:29:33 Voltage Offset Correction: v_off_ini = 95.089 uV, v_off_fin = 82.964 uV 12:29:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.564 uVs 12:29:33 Integrated Voltage Measurement... 12:29:42 Voltage Offset Correction: v_off_ini = 87.052 uV, v_off_fin = 84.501 uV 12:29:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.410 uVs 12:29:42 Integrated Voltage Measurement... 12:29:51 Voltage Offset Correction: v_off_ini = 97.318 uV, v_off_fin = 91.564 uV 12:29:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.005 uVs 12:29:55 I1X Average and RMS of Measurements VT = -99.274 +- 8.493 uVs I1X = 19.855 +- 1.699 uTm 12:29:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:02 Integrated Voltage Measurement... 12:30:11 Voltage Offset Correction: v_off_ini = 94.088 uV, v_off_fin = 85.379 uV 12:30:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.828 uVs 12:30:11 Integrated Voltage Measurement... 12:30:20 Voltage Offset Correction: v_off_ini = 96.601 uV, v_off_fin = 101.255 uV 12:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.707 uVs 12:30:20 Integrated Voltage Measurement... 12:30:29 Voltage Offset Correction: v_off_ini = 86.570 uV, v_off_fin = 81.600 uV 12:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.577 uVs 12:30:29 Integrated Voltage Measurement... 12:30:38 Voltage Offset Correction: v_off_ini = 91.376 uV, v_off_fin = 92.758 uV 12:30:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.336 uVs 12:30:38 Integrated Voltage Measurement... 12:30:47 Voltage Offset Correction: v_off_ini = 81.842 uV, v_off_fin = 59.299 uV 12:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.016 uVs 12:30:47 Integrated Voltage Measurement... 12:30:56 Voltage Offset Correction: v_off_ini = 81.245 uV, v_off_fin = 84.088 uV 12:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.022 uVs 12:31:00 I1Y Average and RMS of Measurements VT = -254.581 +- 3.687 uVs I1Y = -50.916 +- 0.737 uTm 12:31:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:08 Integrated Voltage Measurement... 12:31:17 Voltage Offset Correction: v_off_ini = 77.092 uV, v_off_fin = 66.025 uV 12:31:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.789 uVs 12:31:17 Integrated Voltage Measurement... 12:31:26 Voltage Offset Correction: v_off_ini = 74.272 uV, v_off_fin = 77.099 uV 12:31:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.515 uVs 12:31:26 Integrated Voltage Measurement... 12:31:35 Voltage Offset Correction: v_off_ini = 70.299 uV, v_off_fin = 45.319 uV 12:31:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.436 uVs 12:31:35 Integrated Voltage Measurement... 12:31:44 Voltage Offset Correction: v_off_ini = 77.742 uV, v_off_fin = 79.141 uV 12:31:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.454 uVs 12:31:44 Integrated Voltage Measurement... 12:31:53 Voltage Offset Correction: v_off_ini = 70.535 uV, v_off_fin = 61.048 uV 12:31:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.358 uVs 12:31:53 Integrated Voltage Measurement... 12:32:02 Voltage Offset Correction: v_off_ini = 71.974 uV, v_off_fin = 76.166 uV 12:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.343 uVs 12:32:05 I2X Average and RMS of Measurements VT = -83.149 +- 10.656 uVs I2X = 7.650 +- 0.980 uTm^2 12:32:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:32:12 Integrated Voltage Measurement... 12:32:21 Voltage Offset Correction: v_off_ini = 70.961 uV, v_off_fin = 89.765 uV 12:32:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.037 uVs 12:32:21 Integrated Voltage Measurement... 12:32:30 Voltage Offset Correction: v_off_ini = 87.650 uV, v_off_fin = 90.739 uV 12:32:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.362 uVs 12:32:31 Integrated Voltage Measurement... 12:32:39 Voltage Offset Correction: v_off_ini = 89.322 uV, v_off_fin = 90.275 uV 12:32:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.031 uVs 12:32:40 Integrated Voltage Measurement... 12:32:49 Voltage Offset Correction: v_off_ini = 79.177 uV, v_off_fin = 84.501 uV 12:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.519 uVs 12:32:49 Integrated Voltage Measurement... 12:32:58 Voltage Offset Correction: v_off_ini = 90.209 uV, v_off_fin = 87.651 uV 12:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.103 uVs 12:32:58 Integrated Voltage Measurement... 12:33:07 Voltage Offset Correction: v_off_ini = 93.008 uV, v_off_fin = 93.266 uV 12:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.213 uVs 12:33:09 I2Y Average and RMS of Measurements VT = -314.044 +- 5.635 uVs I2Y = -28.892 +- 0.518 uTm^2 12:33:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:33:18 Integrated Voltage Measurement... 12:33:27 Voltage Offset Correction: v_off_ini = 82.597 uV, v_off_fin = 64.409 uV 12:33:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.667 uVs 12:33:27 Integrated Voltage Measurement... 12:33:36 Voltage Offset Correction: v_off_ini = 71.444 uV, v_off_fin = 87.912 uV 12:33:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.494 uVs 12:33:36 Integrated Voltage Measurement... 12:33:45 Voltage Offset Correction: v_off_ini = 87.213 uV, v_off_fin = 70.331 uV 12:33:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.570 uVs 12:33:45 Integrated Voltage Measurement... 12:33:54 Voltage Offset Correction: v_off_ini = 74.343 uV, v_off_fin = 87.339 uV 12:33:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.287 uVs 12:33:54 Integrated Voltage Measurement... 12:34:03 Voltage Offset Correction: v_off_ini = 84.692 uV, v_off_fin = 91.487 uV 12:34:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.817 uVs 12:34:03 Integrated Voltage Measurement... 12:34:12 Voltage Offset Correction: v_off_ini = 82.952 uV, v_off_fin = 96.848 uV 12:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.297 uVs 12:34:16 I1X Average and RMS of Measurements VT = -105.689 +- 7.661 uVs I1X = 21.138 +- 1.532 uTm 12:34:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:34:23 Integrated Voltage Measurement... 12:34:32 Voltage Offset Correction: v_off_ini = 89.943 uV, v_off_fin = 75.033 uV 12:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -274.246 uVs 12:34:32 Integrated Voltage Measurement... 12:34:41 Voltage Offset Correction: v_off_ini = 94.703 uV, v_off_fin = 102.256 uV 12:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.600 uVs 12:34:41 Integrated Voltage Measurement... 12:34:50 Voltage Offset Correction: v_off_ini = 93.247 uV, v_off_fin = 79.281 uV 12:34:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.624 uVs 12:34:50 Integrated Voltage Measurement... 12:34:59 Voltage Offset Correction: v_off_ini = 82.546 uV, v_off_fin = 88.782 uV 12:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.990 uVs 12:34:59 Integrated Voltage Measurement... 12:35:08 Voltage Offset Correction: v_off_ini = 67.782 uV, v_off_fin = 66.789 uV 12:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.036 uVs 12:35:08 Integrated Voltage Measurement... 12:35:17 Voltage Offset Correction: v_off_ini = 92.423 uV, v_off_fin = 105.247 uV 12:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.564 uVs 12:35:21 I1Y Average and RMS of Measurements VT = -272.343 +- 5.003 uVs I1Y = -54.470 +- 1.002 uTm 12:35:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:35:29 Integrated Voltage Measurement... 12:35:38 Voltage Offset Correction: v_off_ini = 88.150 uV, v_off_fin = 84.025 uV 12:35:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -92.526 uVs 12:35:38 Integrated Voltage Measurement... 12:35:47 Voltage Offset Correction: v_off_ini = 101.636 uV, v_off_fin = 81.049 uV 12:35:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.022 uVs 12:35:47 Integrated Voltage Measurement... 12:35:56 Voltage Offset Correction: v_off_ini = 80.858 uV, v_off_fin = 71.682 uV 12:35:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.073 uVs 12:35:56 Integrated Voltage Measurement... 12:36:05 Voltage Offset Correction: v_off_ini = 74.058 uV, v_off_fin = 80.261 uV 12:36:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.226 uVs 12:36:05 Integrated Voltage Measurement... 12:36:14 Voltage Offset Correction: v_off_ini = 74.643 uV, v_off_fin = 69.226 uV 12:36:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.180 uVs 12:36:14 Integrated Voltage Measurement... 12:36:23 Voltage Offset Correction: v_off_ini = 81.889 uV, v_off_fin = 93.786 uV 12:36:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.253 uVs 12:36:26 I2X Average and RMS of Measurements VT = -86.880 +- 2.444 uVs I2X = 7.993 +- 0.225 uTm^2 12:36:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:36:33 Integrated Voltage Measurement... 12:36:42 Voltage Offset Correction: v_off_ini = 86.192 uV, v_off_fin = 76.712 uV 12:36:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.156 uVs 12:36:42 Integrated Voltage Measurement... 12:36:51 Voltage Offset Correction: v_off_ini = 87.514 uV, v_off_fin = 86.646 uV 12:36:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.828 uVs 12:36:52 Integrated Voltage Measurement... 12:37:00 Voltage Offset Correction: v_off_ini = 85.456 uV, v_off_fin = 84.644 uV 12:37:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.908 uVs 12:37:01 Integrated Voltage Measurement... 12:37:10 Voltage Offset Correction: v_off_ini = 80.943 uV, v_off_fin = 79.531 uV 12:37:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.921 uVs 12:37:10 Integrated Voltage Measurement... 12:37:19 Voltage Offset Correction: v_off_ini = 83.214 uV, v_off_fin = 73.387 uV 12:37:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -350.609 uVs 12:37:19 Integrated Voltage Measurement... 12:37:28 Voltage Offset Correction: v_off_ini = 78.776 uV, v_off_fin = 78.333 uV 12:37:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.574 uVs 12:37:30 I2Y Average and RMS of Measurements VT = -345.166 +- 2.388 uVs I2Y = -31.755 +- 0.220 uTm^2 12:37:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:37:39 Integrated Voltage Measurement... 12:37:48 Voltage Offset Correction: v_off_ini = 75.108 uV, v_off_fin = 67.545 uV 12:37:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.808 uVs 12:37:48 Integrated Voltage Measurement... 12:37:57 Voltage Offset Correction: v_off_ini = 68.076 uV, v_off_fin = 70.497 uV 12:37:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.017 uVs 12:37:57 Integrated Voltage Measurement... 12:38:06 Voltage Offset Correction: v_off_ini = 64.549 uV, v_off_fin = 54.253 uV 12:38:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.237 uVs 12:38:06 Integrated Voltage Measurement... 12:38:15 Voltage Offset Correction: v_off_ini = 59.681 uV, v_off_fin = 60.696 uV 12:38:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.103 uVs 12:38:15 Integrated Voltage Measurement... 12:38:24 Voltage Offset Correction: v_off_ini = 78.638 uV, v_off_fin = 86.988 uV 12:38:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.371 uVs 12:38:24 Integrated Voltage Measurement... 12:38:33 Voltage Offset Correction: v_off_ini = 93.072 uV, v_off_fin = 73.068 uV 12:38:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.481 uVs 12:38:37 I1X Average and RMS of Measurements VT = -105.336 +- 2.928 uVs I1X = 21.067 +- 0.586 uTm 12:38:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:38:44 Integrated Voltage Measurement... 12:38:53 Voltage Offset Correction: v_off_ini = 66.974 uV, v_off_fin = 62.680 uV 12:38:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.228 uVs 12:38:53 Integrated Voltage Measurement... 12:39:02 Voltage Offset Correction: v_off_ini = 65.881 uV, v_off_fin = 78.783 uV 12:39:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.390 uVs 12:39:02 Integrated Voltage Measurement... 12:39:11 Voltage Offset Correction: v_off_ini = 49.910 uV, v_off_fin = 48.461 uV 12:39:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.543 uVs 12:39:11 Integrated Voltage Measurement... 12:39:20 Voltage Offset Correction: v_off_ini = 71.305 uV, v_off_fin = 75.038 uV 12:39:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.405 uVs 12:39:20 Integrated Voltage Measurement... 12:39:29 Voltage Offset Correction: v_off_ini = 65.274 uV, v_off_fin = 39.481 uV 12:39:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -278.742 uVs 12:39:29 Integrated Voltage Measurement... 12:39:38 Voltage Offset Correction: v_off_ini = 52.618 uV, v_off_fin = 71.610 uV 12:39:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 312.080 uVs 12:39:42 I1Y Average and RMS of Measurements VT = -289.065 +- 4.550 uVs I1Y = -57.813 +- 0.910 uTm 12:39:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:39:50 Integrated Voltage Measurement... 12:39:59 Voltage Offset Correction: v_off_ini = 56.952 uV, v_off_fin = 44.368 uV 12:39:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.555 uVs 12:39:59 Integrated Voltage Measurement... 12:40:08 Voltage Offset Correction: v_off_ini = 66.949 uV, v_off_fin = 76.502 uV 12:40:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.525 uVs 12:40:08 Integrated Voltage Measurement... 12:40:17 Voltage Offset Correction: v_off_ini = 67.009 uV, v_off_fin = 47.310 uV 12:40:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.960 uVs 12:40:17 Integrated Voltage Measurement... 12:40:26 Voltage Offset Correction: v_off_ini = 26.652 uV, v_off_fin = 42.630 uV 12:40:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.447 uVs 12:40:26 Integrated Voltage Measurement... 12:40:35 Voltage Offset Correction: v_off_ini = 39.287 uV, v_off_fin = 25.474 uV 12:40:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.770 uVs 12:40:35 Integrated Voltage Measurement... 12:40:44 Voltage Offset Correction: v_off_ini = 25.990 uV, v_off_fin = 40.187 uV 12:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.174 uVs 12:40:46 I2X Average and RMS of Measurements VT = -94.738 +- 9.323 uVs I2X = 8.716 +- 0.858 uTm^2 12:40:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:40:54 Integrated Voltage Measurement... 12:41:03 Voltage Offset Correction: v_off_ini = 39.485 uV, v_off_fin = 55.108 uV 12:41:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.378 uVs 12:41:03 Integrated Voltage Measurement... 12:41:12 Voltage Offset Correction: v_off_ini = 54.329 uV, v_off_fin = 41.384 uV 12:41:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.192 uVs 12:41:12 Integrated Voltage Measurement... 12:41:21 Voltage Offset Correction: v_off_ini = 56.206 uV, v_off_fin = 47.739 uV 12:41:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.090 uVs 12:41:21 Integrated Voltage Measurement... 12:41:30 Voltage Offset Correction: v_off_ini = 43.245 uV, v_off_fin = 47.556 uV 12:41:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.963 uVs 12:41:30 Integrated Voltage Measurement... 12:41:39 Voltage Offset Correction: v_off_ini = 39.832 uV, v_off_fin = 39.354 uV 12:41:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -355.803 uVs 12:41:39 Integrated Voltage Measurement... 12:41:48 Voltage Offset Correction: v_off_ini = 46.404 uV, v_off_fin = 53.028 uV 12:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.834 uVs 12:41:51 I2Y Average and RMS of Measurements VT = -356.710 +- 8.035 uVs I2Y = -32.818 +- 0.739 uTm^2 12:41:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:42:03 Integrated Voltage Measurement... 12:42:12 Voltage Offset Correction: v_off_ini = 62.062 uV, v_off_fin = 39.140 uV 12:42:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.089 uVs 12:42:12 Integrated Voltage Measurement... 12:42:21 Voltage Offset Correction: v_off_ini = 54.371 uV, v_off_fin = 62.353 uV 12:42:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.448 uVs 12:42:21 Integrated Voltage Measurement... 12:42:30 Voltage Offset Correction: v_off_ini = 49.903 uV, v_off_fin = 50.633 uV 12:42:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.774 uVs 12:42:30 Integrated Voltage Measurement... 12:42:39 Voltage Offset Correction: v_off_ini = 63.866 uV, v_off_fin = 62.251 uV 12:42:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.714 uVs 12:42:39 Integrated Voltage Measurement... 12:42:48 Voltage Offset Correction: v_off_ini = 72.550 uV, v_off_fin = 57.951 uV 12:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.619 uVs 12:42:48 Integrated Voltage Measurement... 12:42:57 Voltage Offset Correction: v_off_ini = 61.159 uV, v_off_fin = 70.331 uV 12:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.681 uVs 12:43:01 I1X Average and RMS of Measurements VT = -113.888 +- 7.375 uVs I1X = 22.778 +- 1.475 uTm 12:43:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:43:08 Integrated Voltage Measurement... 12:43:17 Voltage Offset Correction: v_off_ini = 73.575 uV, v_off_fin = 62.961 uV 12:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.041 uVs 12:43:17 Integrated Voltage Measurement... 12:43:26 Voltage Offset Correction: v_off_ini = 57.559 uV, v_off_fin = 74.466 uV 12:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.683 uVs 12:43:26 Integrated Voltage Measurement... 12:43:35 Voltage Offset Correction: v_off_ini = 58.726 uV, v_off_fin = 37.793 uV 12:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.651 uVs 12:43:35 Integrated Voltage Measurement... 12:43:44 Voltage Offset Correction: v_off_ini = 59.186 uV, v_off_fin = 61.414 uV 12:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.496 uVs 12:43:44 Integrated Voltage Measurement... 12:43:53 Voltage Offset Correction: v_off_ini = 59.214 uV, v_off_fin = 63.981 uV 12:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.909 uVs 12:43:53 Integrated Voltage Measurement... 12:44:02 Voltage Offset Correction: v_off_ini = 83.536 uV, v_off_fin = 90.031 uV 12:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.405 uVs 12:44:06 I1Y Average and RMS of Measurements VT = -257.864 +- 9.078 uVs I1Y = -51.573 +- 1.816 uTm 12:44:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:44:11 Integrated Voltage Measurement... 12:44:20 Voltage Offset Correction: v_off_ini = 65.548 uV, v_off_fin = 69.479 uV 12:44:20 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.651 uVs 12:44:20 Integrated Voltage Measurement... 12:44:29 Voltage Offset Correction: v_off_ini = 63.100 uV, v_off_fin = 65.243 uV 12:44:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.635 uVs 12:44:29 Integrated Voltage Measurement... 12:44:38 Voltage Offset Correction: v_off_ini = 44.182 uV, v_off_fin = 28.078 uV 12:44:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.483 uVs 12:44:38 Integrated Voltage Measurement... 12:44:47 Voltage Offset Correction: v_off_ini = 47.132 uV, v_off_fin = 61.959 uV 12:44:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.432 uVs 12:44:47 Integrated Voltage Measurement... 12:44:56 Voltage Offset Correction: v_off_ini = 46.562 uV, v_off_fin = 49.875 uV 12:44:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.471 uVs 12:44:56 Integrated Voltage Measurement... 12:45:05 Voltage Offset Correction: v_off_ini = 51.716 uV, v_off_fin = 59.625 uV 12:45:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.792 uVs 12:45:07 I2X Average and RMS of Measurements VT = -92.744 +- 4.992 uVs I2X = 8.532 +- 0.459 uTm^2 12:45:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:45:12 Integrated Voltage Measurement... 12:45:21 Voltage Offset Correction: v_off_ini = 43.090 uV, v_off_fin = 39.223 uV 12:45:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.646 uVs 12:45:22 Integrated Voltage Measurement... 12:45:30 Voltage Offset Correction: v_off_ini = 38.217 uV, v_off_fin = 54.066 uV 12:45:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.897 uVs 12:45:31 Integrated Voltage Measurement... 12:45:40 Voltage Offset Correction: v_off_ini = 52.097 uV, v_off_fin = 47.607 uV 12:45:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.869 uVs 12:45:40 Integrated Voltage Measurement... 12:45:49 Voltage Offset Correction: v_off_ini = 62.634 uV, v_off_fin = 41.963 uV 12:45:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.322 uVs 12:45:49 Integrated Voltage Measurement... 12:45:58 Voltage Offset Correction: v_off_ini = 52.805 uV, v_off_fin = 52.208 uV 12:45:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.141 uVs 12:45:58 Integrated Voltage Measurement... 12:46:07 Voltage Offset Correction: v_off_ini = 42.806 uV, v_off_fin = 54.220 uV 12:46:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.193 uVs 12:46:09 I2Y Average and RMS of Measurements VT = -312.678 +- 7.752 uVs I2Y = -28.766 +- 0.713 uTm^2 12:46:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:46:17 Integrated Voltage Measurement... 12:46:26 Voltage Offset Correction: v_off_ini = 71.544 uV, v_off_fin = 54.207 uV 12:46:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.901 uVs 12:46:26 Integrated Voltage Measurement... 12:46:35 Voltage Offset Correction: v_off_ini = 50.975 uV, v_off_fin = 54.427 uV 12:46:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.570 uVs 12:46:35 Integrated Voltage Measurement... 12:46:44 Voltage Offset Correction: v_off_ini = 46.441 uV, v_off_fin = 42.693 uV 12:46:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.333 uVs 12:46:44 Integrated Voltage Measurement... 12:46:53 Voltage Offset Correction: v_off_ini = 59.224 uV, v_off_fin = 60.535 uV 12:46:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.584 uVs 12:46:53 Integrated Voltage Measurement... 12:47:02 Voltage Offset Correction: v_off_ini = 54.466 uV, v_off_fin = 62.711 uV 12:47:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -97.900 uVs 12:47:02 Integrated Voltage Measurement... 12:47:11 Voltage Offset Correction: v_off_ini = 60.772 uV, v_off_fin = 63.230 uV 12:47:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 95.778 uVs 12:47:16 I1X Average and RMS of Measurements VT = -95.178 +- 4.950 uVs I1X = 19.037 +- 0.990 uTm 12:47:18 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:47:22 Integrated Voltage Measurement... 12:47:31 Voltage Offset Correction: v_off_ini = 54.250 uV, v_off_fin = 51.818 uV 12:47:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.477 uVs 12:47:31 Integrated Voltage Measurement... 12:47:40 Voltage Offset Correction: v_off_ini = 56.009 uV, v_off_fin = 64.217 uV 12:47:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.197 uVs 12:47:40 Integrated Voltage Measurement... 12:47:49 Voltage Offset Correction: v_off_ini = 74.486 uV, v_off_fin = 62.745 uV 12:47:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.313 uVs 12:47:49 Integrated Voltage Measurement... 12:47:58 Voltage Offset Correction: v_off_ini = 86.601 uV, v_off_fin = 78.586 uV 12:47:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.211 uVs 12:47:58 Integrated Voltage Measurement... 12:48:07 Voltage Offset Correction: v_off_ini = 71.040 uV, v_off_fin = 55.759 uV 12:48:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.161 uVs 12:48:07 Integrated Voltage Measurement... 12:48:16 Voltage Offset Correction: v_off_ini = 72.038 uV, v_off_fin = 76.636 uV 12:48:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.633 uVs 12:48:20 I1Y Average and RMS of Measurements VT = -257.665 +- 4.544 uVs I1Y = -51.534 +- 0.908 uTm 12:48:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:48:26 Integrated Voltage Measurement... 12:48:35 Voltage Offset Correction: v_off_ini = 67.923 uV, v_off_fin = 57.145 uV 12:48:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.537 uVs 12:48:35 Integrated Voltage Measurement... 12:48:44 Voltage Offset Correction: v_off_ini = 71.019 uV, v_off_fin = 71.434 uV 12:48:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.862 uVs 12:48:44 Integrated Voltage Measurement... 12:48:53 Voltage Offset Correction: v_off_ini = 54.088 uV, v_off_fin = 53.174 uV 12:48:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.867 uVs 12:48:53 Integrated Voltage Measurement... 12:49:02 Voltage Offset Correction: v_off_ini = 66.161 uV, v_off_fin = 62.126 uV 12:49:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.727 uVs 12:49:02 Integrated Voltage Measurement... 12:49:11 Voltage Offset Correction: v_off_ini = 63.063 uV, v_off_fin = 40.291 uV 12:49:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.214 uVs 12:49:11 Integrated Voltage Measurement... 12:49:20 Voltage Offset Correction: v_off_ini = 58.852 uV, v_off_fin = 56.942 uV 12:49:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.533 uVs 12:49:22 I2X Average and RMS of Measurements VT = -94.123 +- 5.809 uVs I2X = 8.659 +- 0.534 uTm^2 12:49:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:49:27 Integrated Voltage Measurement... 12:49:36 Voltage Offset Correction: v_off_ini = 66.311 uV, v_off_fin = 69.941 uV 12:49:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.293 uVs 12:49:36 Integrated Voltage Measurement... 12:49:45 Voltage Offset Correction: v_off_ini = 65.181 uV, v_off_fin = 72.767 uV 12:49:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.029 uVs 12:49:45 Integrated Voltage Measurement... 12:49:54 Voltage Offset Correction: v_off_ini = 62.592 uV, v_off_fin = 54.121 uV 12:49:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.885 uVs 12:49:54 Integrated Voltage Measurement... 12:50:03 Voltage Offset Correction: v_off_ini = 64.394 uV, v_off_fin = 71.872 uV 12:50:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.628 uVs 12:50:03 Integrated Voltage Measurement... 12:50:12 Voltage Offset Correction: v_off_ini = 64.507 uV, v_off_fin = 63.872 uV 12:50:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.278 uVs 12:50:12 Integrated Voltage Measurement... 12:50:21 Voltage Offset Correction: v_off_ini = 72.643 uV, v_off_fin = 72.085 uV 12:50:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.234 uVs 12:50:24 I2Y Average and RMS of Measurements VT = -308.224 +- 3.935 uVs I2Y = -28.357 +- 0.362 uTm^2 12:50:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:32 Integrated Voltage Measurement... 12:50:41 Voltage Offset Correction: v_off_ini = 75.302 uV, v_off_fin = 66.255 uV 12:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.442 uVs 12:50:41 Integrated Voltage Measurement... 12:50:50 Voltage Offset Correction: v_off_ini = 65.284 uV, v_off_fin = 63.924 uV 12:50:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.433 uVs 12:50:50 Integrated Voltage Measurement... 12:50:59 Voltage Offset Correction: v_off_ini = 68.294 uV, v_off_fin = 65.277 uV 12:50:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.306 uVs 12:50:59 Integrated Voltage Measurement... 12:51:08 Voltage Offset Correction: v_off_ini = 85.695 uV, v_off_fin = 92.107 uV 12:51:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.561 uVs 12:51:08 Integrated Voltage Measurement... 12:51:17 Voltage Offset Correction: v_off_ini = 84.984 uV, v_off_fin = 69.535 uV 12:51:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.195 uVs 12:51:17 Integrated Voltage Measurement... 12:51:26 Voltage Offset Correction: v_off_ini = 74.116 uV, v_off_fin = 77.775 uV 12:51:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.769 uVs 12:51:30 I1X Average and RMS of Measurements VT = -98.284 +- 7.528 uVs I1X = 19.657 +- 1.505 uTm 12:51:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:51:37 Integrated Voltage Measurement... 12:51:46 Voltage Offset Correction: v_off_ini = 74.267 uV, v_off_fin = 62.162 uV 12:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.959 uVs 12:51:46 Integrated Voltage Measurement... 12:51:55 Voltage Offset Correction: v_off_ini = 82.106 uV, v_off_fin = 91.450 uV 12:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.572 uVs 12:51:55 Integrated Voltage Measurement... 12:52:04 Voltage Offset Correction: v_off_ini = 86.216 uV, v_off_fin = 61.239 uV 12:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.708 uVs 12:52:04 Integrated Voltage Measurement... 12:52:13 Voltage Offset Correction: v_off_ini = 71.947 uV, v_off_fin = 80.824 uV 12:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.066 uVs 12:52:13 Integrated Voltage Measurement... 12:52:22 Voltage Offset Correction: v_off_ini = 66.327 uV, v_off_fin = 55.686 uV 12:52:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.009 uVs 12:52:22 Integrated Voltage Measurement... 12:52:31 Voltage Offset Correction: v_off_ini = 58.333 uV, v_off_fin = 71.285 uV 12:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.456 uVs 12:52:35 I1Y Average and RMS of Measurements VT = -258.961 +- 2.720 uVs I1Y = -51.792 +- 0.544 uTm 12:52:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:40 Integrated Voltage Measurement... 12:52:49 Voltage Offset Correction: v_off_ini = 65.010 uV, v_off_fin = 46.610 uV 12:52:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.182 uVs 12:52:49 Integrated Voltage Measurement... 12:52:58 Voltage Offset Correction: v_off_ini = 62.365 uV, v_off_fin = 83.165 uV 12:52:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.075 uVs 12:52:59 Integrated Voltage Measurement... 12:53:08 Voltage Offset Correction: v_off_ini = 63.852 uV, v_off_fin = 62.500 uV 12:53:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.342 uVs 12:53:08 Integrated Voltage Measurement... 12:53:17 Voltage Offset Correction: v_off_ini = 60.190 uV, v_off_fin = 65.480 uV 12:53:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.451 uVs 12:53:17 Integrated Voltage Measurement... 12:53:26 Voltage Offset Correction: v_off_ini = 62.606 uV, v_off_fin = 54.362 uV 12:53:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.292 uVs 12:53:26 Integrated Voltage Measurement... 12:53:35 Voltage Offset Correction: v_off_ini = 60.440 uV, v_off_fin = 61.965 uV 12:53:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.950 uVs 12:53:37 I2X Average and RMS of Measurements VT = -83.549 +- 9.703 uVs I2X = 7.686 +- 0.893 uTm^2 12:53:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:42 Integrated Voltage Measurement... 12:53:51 Voltage Offset Correction: v_off_ini = 72.224 uV, v_off_fin = 74.958 uV 12:53:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.762 uVs 12:53:51 Integrated Voltage Measurement... 12:54:00 Voltage Offset Correction: v_off_ini = 76.359 uV, v_off_fin = 92.507 uV 12:54:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.540 uVs 12:54:00 Integrated Voltage Measurement... 12:54:09 Voltage Offset Correction: v_off_ini = 86.142 uV, v_off_fin = 76.271 uV 12:54:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.126 uVs 12:54:09 Integrated Voltage Measurement... 12:54:18 Voltage Offset Correction: v_off_ini = 72.210 uV, v_off_fin = 67.807 uV 12:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.889 uVs 12:54:18 Integrated Voltage Measurement... 12:54:27 Voltage Offset Correction: v_off_ini = 71.810 uV, v_off_fin = 71.992 uV 12:54:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.718 uVs 12:54:27 Integrated Voltage Measurement... 12:54:36 Voltage Offset Correction: v_off_ini = 73.438 uV, v_off_fin = 71.515 uV 12:54:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.101 uVs 12:54:39 I2Y Average and RMS of Measurements VT = -309.689 +- 7.322 uVs I2Y = -28.491 +- 0.674 uTm^2 12:54:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:54:47 Integrated Voltage Measurement... 12:54:56 Voltage Offset Correction: v_off_ini = 49.225 uV, v_off_fin = 58.716 uV 12:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.836 uVs 12:54:56 Integrated Voltage Measurement... 12:55:05 Voltage Offset Correction: v_off_ini = 55.643 uV, v_off_fin = 64.189 uV 12:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.618 uVs 12:55:05 Integrated Voltage Measurement... 12:55:14 Voltage Offset Correction: v_off_ini = 46.462 uV, v_off_fin = 34.277 uV 12:55:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.962 uVs 12:55:14 Integrated Voltage Measurement... 12:55:23 Voltage Offset Correction: v_off_ini = 48.651 uV, v_off_fin = 41.283 uV 12:55:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.684 uVs 12:55:23 Integrated Voltage Measurement... 12:55:32 Voltage Offset Correction: v_off_ini = 31.517 uV, v_off_fin = 29.886 uV 12:55:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.768 uVs 12:55:32 Integrated Voltage Measurement... 12:55:41 Voltage Offset Correction: v_off_ini = 33.220 uV, v_off_fin = 53.260 uV 12:55:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 80.037 uVs 12:55:46 I1X Average and RMS of Measurements VT = -78.984 +- 7.801 uVs I1X = 15.797 +- 1.560 uTm 12:55:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:55:52 Integrated Voltage Measurement... 12:56:01 Voltage Offset Correction: v_off_ini = 51.372 uV, v_off_fin = 46.928 uV 12:56:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.646 uVs 12:56:01 Integrated Voltage Measurement... 12:56:10 Voltage Offset Correction: v_off_ini = 56.415 uV, v_off_fin = 68.890 uV 12:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.265 uVs 12:56:10 Integrated Voltage Measurement... 12:56:19 Voltage Offset Correction: v_off_ini = 33.615 uV, v_off_fin = 21.286 uV 12:56:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.024 uVs 12:56:19 Integrated Voltage Measurement... 12:56:28 Voltage Offset Correction: v_off_ini = 27.926 uV, v_off_fin = 34.299 uV 12:56:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.248 uVs 12:56:28 Integrated Voltage Measurement... 12:56:37 Voltage Offset Correction: v_off_ini = 40.792 uV, v_off_fin = 22.692 uV 12:56:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.662 uVs 12:56:37 Integrated Voltage Measurement... 12:56:46 Voltage Offset Correction: v_off_ini = 36.743 uV, v_off_fin = 39.663 uV 12:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.543 uVs 12:56:51 I1Y Average and RMS of Measurements VT = -247.398 +- 2.109 uVs I1Y = -49.480 +- 0.422 uTm 12:56:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:56:56 Integrated Voltage Measurement... 12:57:05 Voltage Offset Correction: v_off_ini = 16.754 uV, v_off_fin = 11.797 uV 12:57:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.457 uVs 12:57:05 Integrated Voltage Measurement... 12:57:14 Voltage Offset Correction: v_off_ini = 16.420 uV, v_off_fin = 22.583 uV 12:57:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.880 uVs 12:57:14 Integrated Voltage Measurement... 12:57:23 Voltage Offset Correction: v_off_ini = 13.849 uV, v_off_fin = 20.020 uV 12:57:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.008 uVs 12:57:23 Integrated Voltage Measurement... 12:57:32 Voltage Offset Correction: v_off_ini = 30.969 uV, v_off_fin = 50.792 uV 12:57:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.171 uVs 12:57:32 Integrated Voltage Measurement... 12:57:41 Voltage Offset Correction: v_off_ini = 31.614 uV, v_off_fin = 26.576 uV 12:57:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.164 uVs 12:57:41 Integrated Voltage Measurement... 12:57:50 Voltage Offset Correction: v_off_ini = 40.675 uV, v_off_fin = 43.446 uV 12:57:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.477 uVs 12:57:52 I2X Average and RMS of Measurements VT = -78.359 +- 7.377 uVs I2X = 7.209 +- 0.679 uTm^2 12:57:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:57:57 Integrated Voltage Measurement... 12:58:06 Voltage Offset Correction: v_off_ini = 2.967 uV, v_off_fin = 17.079 uV 12:58:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.523 uVs 12:58:07 Integrated Voltage Measurement... 12:58:15 Voltage Offset Correction: v_off_ini = 16.211 uV, v_off_fin = 31.952 uV 12:58:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.534 uVs 12:58:16 Integrated Voltage Measurement... 12:58:25 Voltage Offset Correction: v_off_ini = 19.681 uV, v_off_fin = 16.169 uV 12:58:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.684 uVs 12:58:25 Integrated Voltage Measurement... 12:58:34 Voltage Offset Correction: v_off_ini = 19.254 uV, v_off_fin = 16.960 uV 12:58:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 318.439 uVs 12:58:34 Integrated Voltage Measurement... 12:58:43 Voltage Offset Correction: v_off_ini = 25.697 uV, v_off_fin = 22.479 uV 12:58:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.712 uVs 12:58:43 Integrated Voltage Measurement... 12:58:52 Voltage Offset Correction: v_off_ini = 26.976 uV, v_off_fin = 30.278 uV 12:58:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.788 uVs 12:58:54 I2Y Average and RMS of Measurements VT = -308.780 +- 4.470 uVs I2Y = -28.408 +- 0.412 uTm^2 12:58:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:59:02 Integrated Voltage Measurement... 12:59:11 Voltage Offset Correction: v_off_ini = 39.113 uV, v_off_fin = 29.560 uV 12:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.337 uVs 12:59:11 Integrated Voltage Measurement... 12:59:20 Voltage Offset Correction: v_off_ini = 33.143 uV, v_off_fin = 38.407 uV 12:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.953 uVs 12:59:21 Integrated Voltage Measurement... 12:59:29 Voltage Offset Correction: v_off_ini = 29.003 uV, v_off_fin = 21.797 uV 12:59:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.621 uVs 12:59:30 Integrated Voltage Measurement... 12:59:38 Voltage Offset Correction: v_off_ini = 27.942 uV, v_off_fin = 37.605 uV 12:59:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.314 uVs 12:59:39 Integrated Voltage Measurement... 12:59:48 Voltage Offset Correction: v_off_ini = 41.093 uV, v_off_fin = 28.623 uV 12:59:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.088 uVs 12:59:48 Integrated Voltage Measurement... 12:59:57 Voltage Offset Correction: v_off_ini = 37.478 uV, v_off_fin = 34.965 uV 12:59:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.840 uVs 13:00:01 I1X Average and RMS of Measurements VT = -66.359 +- 3.137 uVs I1X = 13.272 +- 0.627 uTm 13:00:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:00:08 Integrated Voltage Measurement... 13:00:17 Voltage Offset Correction: v_off_ini = 44.290 uV, v_off_fin = 29.077 uV 13:00:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.690 uVs 13:00:17 Integrated Voltage Measurement... 13:00:26 Voltage Offset Correction: v_off_ini = 49.426 uV, v_off_fin = 63.231 uV 13:00:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.601 uVs 13:00:26 Integrated Voltage Measurement... 13:00:35 Voltage Offset Correction: v_off_ini = 39.980 uV, v_off_fin = 28.917 uV 13:00:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.489 uVs 13:00:35 Integrated Voltage Measurement... 13:00:44 Voltage Offset Correction: v_off_ini = 41.511 uV, v_off_fin = 52.082 uV 13:00:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.710 uVs 13:00:44 Integrated Voltage Measurement... 13:00:53 Voltage Offset Correction: v_off_ini = 47.876 uV, v_off_fin = 37.406 uV 13:00:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.795 uVs 13:00:53 Integrated Voltage Measurement... 13:01:02 Voltage Offset Correction: v_off_ini = 47.064 uV, v_off_fin = 40.561 uV 13:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.732 uVs 13:01:06 I1Y Average and RMS of Measurements VT = -246.669 +- 5.409 uVs I1Y = -49.334 +- 1.082 uTm 13:01:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:01:11 Integrated Voltage Measurement... 13:01:20 Voltage Offset Correction: v_off_ini = 31.142 uV, v_off_fin = 22.774 uV 13:01:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.662 uVs 13:01:20 Integrated Voltage Measurement... 13:01:29 Voltage Offset Correction: v_off_ini = 36.593 uV, v_off_fin = 20.225 uV 13:01:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.498 uVs 13:01:29 Integrated Voltage Measurement... 13:01:38 Voltage Offset Correction: v_off_ini = 26.237 uV, v_off_fin = 15.744 uV 13:01:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.158 uVs 13:01:38 Integrated Voltage Measurement... 13:01:47 Voltage Offset Correction: v_off_ini = 21.974 uV, v_off_fin = 45.795 uV 13:01:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.697 uVs 13:01:47 Integrated Voltage Measurement... 13:01:56 Voltage Offset Correction: v_off_ini = 27.720 uV, v_off_fin = 26.927 uV 13:01:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.544 uVs 13:01:56 Integrated Voltage Measurement... 13:02:05 Voltage Offset Correction: v_off_ini = 53.896 uV, v_off_fin = 54.303 uV 13:02:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.112 uVs 13:02:08 I2X Average and RMS of Measurements VT = -48.612 +- 1.578 uVs I2X = 4.472 +- 0.145 uTm^2 13:02:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:02:13 Integrated Voltage Measurement... 13:02:22 Voltage Offset Correction: v_off_ini = 41.564 uV, v_off_fin = 39.296 uV 13:02:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.399 uVs 13:02:22 Integrated Voltage Measurement... 13:02:31 Voltage Offset Correction: v_off_ini = 51.132 uV, v_off_fin = 48.638 uV 13:02:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.913 uVs 13:02:31 Integrated Voltage Measurement... 13:02:40 Voltage Offset Correction: v_off_ini = 56.742 uV, v_off_fin = 51.275 uV 13:02:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.278 uVs 13:02:40 Integrated Voltage Measurement... 13:02:49 Voltage Offset Correction: v_off_ini = 47.054 uV, v_off_fin = 53.314 uV 13:02:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.192 uVs 13:02:49 Integrated Voltage Measurement... 13:02:58 Voltage Offset Correction: v_off_ini = 64.448 uV, v_off_fin = 63.659 uV 13:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.648 uVs 13:02:58 Integrated Voltage Measurement... 13:03:07 Voltage Offset Correction: v_off_ini = 57.383 uV, v_off_fin = 68.677 uV 13:03:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.968 uVs 13:03:09 I2Y Average and RMS of Measurements VT = -310.733 +- 4.258 uVs I2Y = -28.587 +- 0.392 uTm^2 13:03:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:03:29 Integrated Voltage Measurement... 13:03:38 Voltage Offset Correction: v_off_ini = 53.377 uV, v_off_fin = 38.555 uV 13:03:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.047 uVs 13:03:39 Integrated Voltage Measurement... 13:03:47 Voltage Offset Correction: v_off_ini = 45.676 uV, v_off_fin = 57.508 uV 13:03:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 113.645 uVs 13:03:48 Integrated Voltage Measurement... 13:03:57 Voltage Offset Correction: v_off_ini = 63.935 uV, v_off_fin = 40.558 uV 13:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.001 uVs 13:03:57 Integrated Voltage Measurement... 13:04:06 Voltage Offset Correction: v_off_ini = 48.907 uV, v_off_fin = 61.700 uV 13:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.922 uVs 13:04:06 Integrated Voltage Measurement... 13:04:15 Voltage Offset Correction: v_off_ini = 66.497 uV, v_off_fin = 67.909 uV 13:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.618 uVs 13:04:15 Integrated Voltage Measurement... 13:04:24 Voltage Offset Correction: v_off_ini = 63.676 uV, v_off_fin = 71.557 uV 13:04:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.783 uVs 13:04:28 I1X Average and RMS of Measurements VT = -111.836 +- 4.890 uVs I1X = 22.368 +- 0.978 uTm 13:04:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:04:35 Integrated Voltage Measurement... 13:04:44 Voltage Offset Correction: v_off_ini = 79.202 uV, v_off_fin = 64.654 uV 13:04:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.216 uVs 13:04:44 Integrated Voltage Measurement... 13:04:53 Voltage Offset Correction: v_off_ini = 61.530 uV, v_off_fin = 72.099 uV 13:04:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.642 uVs 13:04:53 Integrated Voltage Measurement... 13:05:02 Voltage Offset Correction: v_off_ini = 80.564 uV, v_off_fin = 42.117 uV 13:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.571 uVs 13:05:02 Integrated Voltage Measurement... 13:05:11 Voltage Offset Correction: v_off_ini = 54.706 uV, v_off_fin = 48.496 uV 13:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.457 uVs 13:05:11 Integrated Voltage Measurement... 13:05:20 Voltage Offset Correction: v_off_ini = 48.590 uV, v_off_fin = 39.487 uV 13:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.831 uVs 13:05:20 Integrated Voltage Measurement... 13:05:29 Voltage Offset Correction: v_off_ini = 61.566 uV, v_off_fin = 72.388 uV 13:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.411 uVs 13:05:33 I1Y Average and RMS of Measurements VT = -214.521 +- 5.077 uVs I1Y = -42.904 +- 1.015 uTm 13:05:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:05:41 Integrated Voltage Measurement... 13:05:50 Voltage Offset Correction: v_off_ini = 62.700 uV, v_off_fin = 51.909 uV 13:05:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.594 uVs 13:05:50 Integrated Voltage Measurement... 13:05:59 Voltage Offset Correction: v_off_ini = 52.014 uV, v_off_fin = 59.574 uV 13:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.403 uVs 13:05:59 Integrated Voltage Measurement... 13:06:08 Voltage Offset Correction: v_off_ini = 66.044 uV, v_off_fin = 52.541 uV 13:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.421 uVs 13:06:08 Integrated Voltage Measurement... 13:06:17 Voltage Offset Correction: v_off_ini = 41.991 uV, v_off_fin = 63.329 uV 13:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.790 uVs 13:06:17 Integrated Voltage Measurement... 13:06:26 Voltage Offset Correction: v_off_ini = 55.541 uV, v_off_fin = 50.760 uV 13:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.597 uVs 13:06:26 Integrated Voltage Measurement... 13:06:35 Voltage Offset Correction: v_off_ini = 59.107 uV, v_off_fin = 71.415 uV 13:06:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.165 uVs 13:06:37 I2X Average and RMS of Measurements VT = -105.495 +- 1.934 uVs I2X = 9.706 +- 0.178 uTm^2 13:06:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:06:45 Integrated Voltage Measurement... 13:06:54 Voltage Offset Correction: v_off_ini = 63.544 uV, v_off_fin = 63.496 uV 13:06:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.869 uVs 13:06:54 Integrated Voltage Measurement... 13:07:03 Voltage Offset Correction: v_off_ini = 60.838 uV, v_off_fin = 43.250 uV 13:07:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.183 uVs 13:07:03 Integrated Voltage Measurement... 13:07:12 Voltage Offset Correction: v_off_ini = 64.049 uV, v_off_fin = 52.073 uV 13:07:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.566 uVs 13:07:12 Integrated Voltage Measurement... 13:07:21 Voltage Offset Correction: v_off_ini = 48.422 uV, v_off_fin = 52.076 uV 13:07:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.405 uVs 13:07:21 Integrated Voltage Measurement... 13:07:30 Voltage Offset Correction: v_off_ini = 58.846 uV, v_off_fin = 44.954 uV 13:07:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.863 uVs 13:07:30 Integrated Voltage Measurement... 13:07:39 Voltage Offset Correction: v_off_ini = 43.258 uV, v_off_fin = 32.390 uV 13:07:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.494 uVs 13:07:42 I2Y Average and RMS of Measurements VT = -263.730 +- 3.895 uVs I2Y = -24.263 +- 0.358 uTm^2 13:07:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:07:51 Integrated Voltage Measurement... 13:07:59 Voltage Offset Correction: v_off_ini = 38.383 uV, v_off_fin = 35.410 uV 13:08:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.218 uVs 13:08:00 Integrated Voltage Measurement... 13:08:09 Voltage Offset Correction: v_off_ini = 42.236 uV, v_off_fin = 48.875 uV 13:08:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.008 uVs 13:08:09 Integrated Voltage Measurement... 13:08:18 Voltage Offset Correction: v_off_ini = 29.208 uV, v_off_fin = 22.149 uV 13:08:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.141 uVs 13:08:18 Integrated Voltage Measurement... 13:08:27 Voltage Offset Correction: v_off_ini = 35.155 uV, v_off_fin = 39.125 uV 13:08:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.201 uVs 13:08:27 Integrated Voltage Measurement... 13:08:36 Voltage Offset Correction: v_off_ini = 40.431 uV, v_off_fin = 31.938 uV 13:08:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.920 uVs 13:08:36 Integrated Voltage Measurement... 13:08:45 Voltage Offset Correction: v_off_ini = 38.522 uV, v_off_fin = 32.118 uV 13:08:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.643 uVs 13:08:49 I1X Average and RMS of Measurements VT = -112.688 +- 5.077 uVs I1X = 22.538 +- 1.015 uTm 13:08:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:08:56 Integrated Voltage Measurement... 13:09:05 Voltage Offset Correction: v_off_ini = 17.459 uV, v_off_fin = -2.152 uV 13:09:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.124 uVs 13:09:05 Integrated Voltage Measurement... 13:09:14 Voltage Offset Correction: v_off_ini = 17.068 uV, v_off_fin = 27.674 uV 13:09:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.492 uVs 13:09:14 Integrated Voltage Measurement... 13:09:23 Voltage Offset Correction: v_off_ini = 22.519 uV, v_off_fin = 9.620 uV 13:09:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.836 uVs 13:09:23 Integrated Voltage Measurement... 13:09:32 Voltage Offset Correction: v_off_ini = 25.321 uV, v_off_fin = 32.881 uV 13:09:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.608 uVs 13:09:32 Integrated Voltage Measurement... 13:09:41 Voltage Offset Correction: v_off_ini = 19.946 uV, v_off_fin = 3.959 uV 13:09:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.371 uVs 13:09:41 Integrated Voltage Measurement... 13:09:50 Voltage Offset Correction: v_off_ini = 28.531 uV, v_off_fin = 22.709 uV 13:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.721 uVs 13:09:54 I1Y Average and RMS of Measurements VT = -239.359 +- 3.764 uVs I1Y = -47.872 +- 0.753 uTm 13:09:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:10:02 Integrated Voltage Measurement... 13:10:11 Voltage Offset Correction: v_off_ini = 8.280 uV, v_off_fin = -15.364 uV 13:10:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.952 uVs 13:10:11 Integrated Voltage Measurement... 13:10:20 Voltage Offset Correction: v_off_ini = -2.634 uV, v_off_fin = 15.587 uV 13:10:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.256 uVs 13:10:20 Integrated Voltage Measurement... 13:10:29 Voltage Offset Correction: v_off_ini = 1.385 uV, v_off_fin = -19.591 uV 13:10:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.718 uVs 13:10:29 Integrated Voltage Measurement... 13:10:38 Voltage Offset Correction: v_off_ini = -0.579 uV, v_off_fin = 10.297 uV 13:10:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.537 uVs 13:10:38 Integrated Voltage Measurement... 13:10:47 Voltage Offset Correction: v_off_ini = -18.449 uV, v_off_fin = -10.087 uV 13:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.787 uVs 13:10:47 Integrated Voltage Measurement... 13:10:56 Voltage Offset Correction: v_off_ini = 17.241 uV, v_off_fin = 15.060 uV 13:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.049 uVs 13:10:58 I2X Average and RMS of Measurements VT = -98.383 +- 4.550 uVs I2X = 9.051 +- 0.419 uTm^2 13:11:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:11:06 Integrated Voltage Measurement... 13:11:15 Voltage Offset Correction: v_off_ini = -10.559 uV, v_off_fin = -12.561 uV 13:11:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.021 uVs 13:11:15 Integrated Voltage Measurement... 13:11:24 Voltage Offset Correction: v_off_ini = -9.391 uV, v_off_fin = -9.241 uV 13:11:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.196 uVs 13:11:24 Integrated Voltage Measurement... 13:11:33 Voltage Offset Correction: v_off_ini = -19.930 uV, v_off_fin = -15.820 uV 13:11:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.694 uVs 13:11:33 Integrated Voltage Measurement... 13:11:42 Voltage Offset Correction: v_off_ini = -10.038 uV, v_off_fin = -15.725 uV 13:11:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.098 uVs 13:11:42 Integrated Voltage Measurement... 13:11:51 Voltage Offset Correction: v_off_ini = -20.458 uV, v_off_fin = -18.159 uV 13:11:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.525 uVs 13:11:51 Integrated Voltage Measurement... 13:12:00 Voltage Offset Correction: v_off_ini = -11.688 uV, v_off_fin = -11.504 uV 13:12:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.970 uVs 13:12:03 I2Y Average and RMS of Measurements VT = -293.417 +- 3.160 uVs I2Y = -26.994 +- 0.291 uTm^2 13:12:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:12 Integrated Voltage Measurement... 13:12:21 Voltage Offset Correction: v_off_ini = -13.391 uV, v_off_fin = -19.817 uV 13:12:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.042 uVs 13:12:21 Integrated Voltage Measurement... 13:12:30 Voltage Offset Correction: v_off_ini = -10.724 uV, v_off_fin = -4.842 uV 13:12:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.711 uVs 13:12:30 Integrated Voltage Measurement... 13:12:39 Voltage Offset Correction: v_off_ini = -17.259 uV, v_off_fin = -14.509 uV 13:12:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.728 uVs 13:12:39 Integrated Voltage Measurement... 13:12:48 Voltage Offset Correction: v_off_ini = -8.992 uV, v_off_fin = -15.287 uV 13:12:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.354 uVs 13:12:48 Integrated Voltage Measurement... 13:12:57 Voltage Offset Correction: v_off_ini = 1.810 uV, v_off_fin = -8.830 uV 13:12:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.905 uVs 13:12:57 Integrated Voltage Measurement... 13:13:06 Voltage Offset Correction: v_off_ini = -2.377 uV, v_off_fin = -10.892 uV 13:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.600 uVs 13:13:10 I1X Average and RMS of Measurements VT = -118.557 +- 9.926 uVs I1X = 23.711 +- 1.985 uTm 13:13:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:17 Integrated Voltage Measurement... 13:13:26 Voltage Offset Correction: v_off_ini = 2.171 uV, v_off_fin = -20.197 uV 13:13:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.540 uVs 13:13:26 Integrated Voltage Measurement... 13:13:35 Voltage Offset Correction: v_off_ini = -11.178 uV, v_off_fin = -12.406 uV 13:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.195 uVs 13:13:35 Integrated Voltage Measurement... 13:13:44 Voltage Offset Correction: v_off_ini = -12.254 uV, v_off_fin = -21.993 uV 13:13:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.114 uVs 13:13:44 Integrated Voltage Measurement... 13:13:53 Voltage Offset Correction: v_off_ini = -13.174 uV, v_off_fin = 1.270 uV 13:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.276 uVs 13:13:53 Integrated Voltage Measurement... 13:14:02 Voltage Offset Correction: v_off_ini = -14.928 uV, v_off_fin = -30.993 uV 13:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.402 uVs 13:14:02 Integrated Voltage Measurement... 13:14:11 Voltage Offset Correction: v_off_ini = -20.890 uV, v_off_fin = -7.703 uV 13:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.512 uVs 13:14:15 I1Y Average and RMS of Measurements VT = -252.840 +- 10.681 uVs I1Y = -50.568 +- 2.136 uTm 13:14:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:22 Integrated Voltage Measurement... 13:14:31 Voltage Offset Correction: v_off_ini = 4.175 uV, v_off_fin = -4.937 uV 13:14:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -110.270 uVs 13:14:32 Integrated Voltage Measurement... 13:14:40 Voltage Offset Correction: v_off_ini = -3.651 uV, v_off_fin = 8.761 uV 13:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.900 uVs 13:14:41 Integrated Voltage Measurement... 13:14:50 Voltage Offset Correction: v_off_ini = 5.267 uV, v_off_fin = 0.129 uV 13:14:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.237 uVs 13:14:50 Integrated Voltage Measurement... 13:14:59 Voltage Offset Correction: v_off_ini = 8.221 uV, v_off_fin = 21.715 uV 13:14:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.777 uVs 13:14:59 Integrated Voltage Measurement... 13:15:08 Voltage Offset Correction: v_off_ini = 22.419 uV, v_off_fin = 32.087 uV 13:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.667 uVs 13:15:08 Integrated Voltage Measurement... 13:15:17 Voltage Offset Correction: v_off_ini = 36.945 uV, v_off_fin = 38.121 uV 13:15:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.490 uVs 13:15:19 I2X Average and RMS of Measurements VT = -112.223 +- 4.567 uVs I2X = 10.324 +- 0.420 uTm^2 13:15:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:27 Integrated Voltage Measurement... 13:15:36 Voltage Offset Correction: v_off_ini = 10.956 uV, v_off_fin = 8.361 uV 13:15:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.432 uVs 13:15:36 Integrated Voltage Measurement... 13:15:45 Voltage Offset Correction: v_off_ini = 12.800 uV, v_off_fin = 24.205 uV 13:15:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.187 uVs 13:15:45 Integrated Voltage Measurement... 13:15:54 Voltage Offset Correction: v_off_ini = 16.728 uV, v_off_fin = 22.621 uV 13:15:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.399 uVs 13:15:54 Integrated Voltage Measurement... 13:16:03 Voltage Offset Correction: v_off_ini = 20.016 uV, v_off_fin = 21.174 uV 13:16:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.371 uVs 13:16:03 Integrated Voltage Measurement... 13:16:12 Voltage Offset Correction: v_off_ini = 16.010 uV, v_off_fin = 19.516 uV 13:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.542 uVs 13:16:12 Integrated Voltage Measurement... 13:16:21 Voltage Offset Correction: v_off_ini = 36.302 uV, v_off_fin = 40.189 uV 13:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.705 uVs 13:16:23 I2Y Average and RMS of Measurements VT = -303.439 +- 9.701 uVs I2Y = -27.916 +- 0.892 uTm^2 13:16:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:16:32 Integrated Voltage Measurement... 13:16:41 Voltage Offset Correction: v_off_ini = 16.855 uV, v_off_fin = 7.482 uV 13:16:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.773 uVs 13:16:41 Integrated Voltage Measurement... 13:16:50 Voltage Offset Correction: v_off_ini = 14.030 uV, v_off_fin = 28.411 uV 13:16:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.908 uVs 13:16:50 Integrated Voltage Measurement... 13:16:59 Voltage Offset Correction: v_off_ini = 21.805 uV, v_off_fin = 9.248 uV 13:16:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.586 uVs 13:16:59 Integrated Voltage Measurement... 13:17:08 Voltage Offset Correction: v_off_ini = 13.145 uV, v_off_fin = 18.799 uV 13:17:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.976 uVs 13:17:08 Integrated Voltage Measurement... 13:17:17 Voltage Offset Correction: v_off_ini = 21.516 uV, v_off_fin = 25.838 uV 13:17:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.016 uVs 13:17:17 Integrated Voltage Measurement... 13:17:26 Voltage Offset Correction: v_off_ini = 19.559 uV, v_off_fin = 17.570 uV 13:17:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.741 uVs 13:17:30 I1X Average and RMS of Measurements VT = -110.167 +- 4.927 uVs I1X = 22.033 +- 0.985 uTm 13:17:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:17:37 Integrated Voltage Measurement... 13:17:46 Voltage Offset Correction: v_off_ini = 21.837 uV, v_off_fin = 10.014 uV 13:17:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.625 uVs 13:17:46 Integrated Voltage Measurement... 13:17:55 Voltage Offset Correction: v_off_ini = 11.134 uV, v_off_fin = 34.147 uV 13:17:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.599 uVs 13:17:55 Integrated Voltage Measurement... 13:18:04 Voltage Offset Correction: v_off_ini = 20.769 uV, v_off_fin = 8.174 uV 13:18:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.130 uVs 13:18:04 Integrated Voltage Measurement... 13:18:13 Voltage Offset Correction: v_off_ini = 13.506 uV, v_off_fin = 29.294 uV 13:18:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.338 uVs 13:18:13 Integrated Voltage Measurement... 13:18:22 Voltage Offset Correction: v_off_ini = 15.411 uV, v_off_fin = -2.621 uV 13:18:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.368 uVs 13:18:22 Integrated Voltage Measurement... 13:18:31 Voltage Offset Correction: v_off_ini = 22.152 uV, v_off_fin = 25.521 uV 13:18:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.374 uVs 13:18:35 I1Y Average and RMS of Measurements VT = -283.906 +- 1.949 uVs I1Y = -56.781 +- 0.390 uTm 13:18:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:18:43 Integrated Voltage Measurement... 13:18:52 Voltage Offset Correction: v_off_ini = 25.470 uV, v_off_fin = 28.064 uV 13:18:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -100.713 uVs 13:18:52 Integrated Voltage Measurement... 13:19:01 Voltage Offset Correction: v_off_ini = 33.846 uV, v_off_fin = 52.943 uV 13:19:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.710 uVs 13:19:01 Integrated Voltage Measurement... 13:19:10 Voltage Offset Correction: v_off_ini = 39.819 uV, v_off_fin = 34.617 uV 13:19:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.154 uVs 13:19:10 Integrated Voltage Measurement... 13:19:19 Voltage Offset Correction: v_off_ini = 39.783 uV, v_off_fin = 36.978 uV 13:19:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.637 uVs 13:19:19 Integrated Voltage Measurement... 13:19:28 Voltage Offset Correction: v_off_ini = 24.203 uV, v_off_fin = 12.668 uV 13:19:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.615 uVs 13:19:28 Integrated Voltage Measurement... 13:19:37 Voltage Offset Correction: v_off_ini = 30.311 uV, v_off_fin = 30.032 uV 13:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.775 uVs 13:19:39 I2X Average and RMS of Measurements VT = -100.434 +- 2.577 uVs I2X = 9.240 +- 0.237 uTm^2 13:19:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:19:47 Integrated Voltage Measurement... 13:19:56 Voltage Offset Correction: v_off_ini = 38.066 uV, v_off_fin = 43.987 uV 13:19:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.335 uVs 13:19:56 Integrated Voltage Measurement... 13:20:05 Voltage Offset Correction: v_off_ini = 43.841 uV, v_off_fin = 44.430 uV 13:20:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.814 uVs 13:20:05 Integrated Voltage Measurement... 13:20:14 Voltage Offset Correction: v_off_ini = 39.683 uV, v_off_fin = 37.465 uV 13:20:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.134 uVs 13:20:14 Integrated Voltage Measurement... 13:20:23 Voltage Offset Correction: v_off_ini = 41.114 uV, v_off_fin = 45.142 uV 13:20:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.905 uVs 13:20:23 Integrated Voltage Measurement... 13:20:32 Voltage Offset Correction: v_off_ini = 56.454 uV, v_off_fin = 45.640 uV 13:20:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.364 uVs 13:20:32 Integrated Voltage Measurement... 13:20:41 Voltage Offset Correction: v_off_ini = 45.218 uV, v_off_fin = 45.630 uV 13:20:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.023 uVs 13:20:44 I2Y Average and RMS of Measurements VT = -330.596 +- 4.671 uVs I2Y = -30.415 +- 0.430 uTm^2 13:20:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:20:53 Integrated Voltage Measurement... 13:21:02 Voltage Offset Correction: v_off_ini = 63.342 uV, v_off_fin = 43.093 uV 13:21:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.630 uVs 13:21:02 Integrated Voltage Measurement... 13:21:11 Voltage Offset Correction: v_off_ini = 43.056 uV, v_off_fin = 31.342 uV 13:21:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.461 uVs 13:21:11 Integrated Voltage Measurement... 13:21:20 Voltage Offset Correction: v_off_ini = 20.675 uV, v_off_fin = 23.823 uV 13:21:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.115 uVs 13:21:20 Integrated Voltage Measurement... 13:21:29 Voltage Offset Correction: v_off_ini = 23.785 uV, v_off_fin = 27.072 uV 13:21:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.533 uVs 13:21:29 Integrated Voltage Measurement... 13:21:38 Voltage Offset Correction: v_off_ini = 24.884 uV, v_off_fin = 24.378 uV 13:21:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.195 uVs 13:21:38 Integrated Voltage Measurement... 13:21:47 Voltage Offset Correction: v_off_ini = 10.859 uV, v_off_fin = 31.082 uV 13:21:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.606 uVs 13:21:51 I1X Average and RMS of Measurements VT = -119.090 +- 1.345 uVs I1X = 23.818 +- 0.269 uTm 13:21:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:21:58 Integrated Voltage Measurement... 13:22:07 Voltage Offset Correction: v_off_ini = 42.299 uV, v_off_fin = 22.753 uV 13:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -310.925 uVs 13:22:07 Integrated Voltage Measurement... 13:22:16 Voltage Offset Correction: v_off_ini = 18.903 uV, v_off_fin = 43.222 uV 13:22:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.670 uVs 13:22:16 Integrated Voltage Measurement... 13:22:25 Voltage Offset Correction: v_off_ini = 16.499 uV, v_off_fin = 14.531 uV 13:22:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.324 uVs 13:22:25 Integrated Voltage Measurement... 13:22:34 Voltage Offset Correction: v_off_ini = 27.500 uV, v_off_fin = 33.637 uV 13:22:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 296.409 uVs 13:22:34 Integrated Voltage Measurement... 13:22:43 Voltage Offset Correction: v_off_ini = 24.154 uV, v_off_fin = 10.580 uV 13:22:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.186 uVs 13:22:43 Integrated Voltage Measurement... 13:22:52 Voltage Offset Correction: v_off_ini = 14.835 uV, v_off_fin = 44.784 uV 13:22:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 305.716 uVs 13:22:56 I1Y Average and RMS of Measurements VT = -297.372 +- 4.897 uVs I1Y = -59.474 +- 0.979 uTm 13:23:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:23:03 Integrated Voltage Measurement... 13:23:12 Voltage Offset Correction: v_off_ini = 43.524 uV, v_off_fin = 26.003 uV 13:23:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.895 uVs 13:23:12 Integrated Voltage Measurement... 13:23:21 Voltage Offset Correction: v_off_ini = 29.692 uV, v_off_fin = 45.494 uV 13:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.265 uVs 13:23:22 Integrated Voltage Measurement... 13:23:30 Voltage Offset Correction: v_off_ini = 26.132 uV, v_off_fin = 31.952 uV 13:23:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.631 uVs 13:23:31 Integrated Voltage Measurement... 13:23:39 Voltage Offset Correction: v_off_ini = 35.394 uV, v_off_fin = 53.707 uV 13:23:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.537 uVs 13:23:40 Integrated Voltage Measurement... 13:23:49 Voltage Offset Correction: v_off_ini = 36.339 uV, v_off_fin = 23.105 uV 13:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.488 uVs 13:23:49 Integrated Voltage Measurement... 13:23:58 Voltage Offset Correction: v_off_ini = 42.253 uV, v_off_fin = 44.169 uV 13:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.506 uVs 13:24:00 I2X Average and RMS of Measurements VT = -106.721 +- 0.653 uVs I2X = 9.818 +- 0.060 uTm^2 13:24:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:24:08 Integrated Voltage Measurement... 13:24:17 Voltage Offset Correction: v_off_ini = 32.214 uV, v_off_fin = 27.295 uV 13:24:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.200 uVs 13:24:17 Integrated Voltage Measurement... 13:24:26 Voltage Offset Correction: v_off_ini = 35.325 uV, v_off_fin = 43.029 uV 13:24:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.158 uVs 13:24:26 Integrated Voltage Measurement... 13:24:35 Voltage Offset Correction: v_off_ini = 46.105 uV, v_off_fin = 48.209 uV 13:24:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.082 uVs 13:24:35 Integrated Voltage Measurement... 13:24:44 Voltage Offset Correction: v_off_ini = 49.010 uV, v_off_fin = 49.135 uV 13:24:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.388 uVs 13:24:44 Integrated Voltage Measurement... 13:24:53 Voltage Offset Correction: v_off_ini = 40.273 uV, v_off_fin = 31.013 uV 13:24:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.668 uVs 13:24:53 Integrated Voltage Measurement... 13:25:02 Voltage Offset Correction: v_off_ini = 46.645 uV, v_off_fin = 46.383 uV 13:25:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.724 uVs 13:25:04 I2Y Average and RMS of Measurements VT = -345.870 +- 6.173 uVs I2Y = -31.820 +- 0.568 uTm^2 13:25:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:25:16 Integrated Voltage Measurement... 13:25:25 Voltage Offset Correction: v_off_ini = 58.836 uV, v_off_fin = 46.086 uV 13:25:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -133.425 uVs 13:25:25 Integrated Voltage Measurement... 13:25:34 Voltage Offset Correction: v_off_ini = 54.063 uV, v_off_fin = 54.405 uV 13:25:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.658 uVs 13:25:34 Integrated Voltage Measurement... 13:25:43 Voltage Offset Correction: v_off_ini = 50.079 uV, v_off_fin = 46.527 uV 13:25:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.775 uVs 13:25:43 Integrated Voltage Measurement... 13:25:52 Voltage Offset Correction: v_off_ini = 39.631 uV, v_off_fin = 38.778 uV 13:25:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.475 uVs 13:25:52 Integrated Voltage Measurement... 13:26:01 Voltage Offset Correction: v_off_ini = 33.234 uV, v_off_fin = 27.949 uV 13:26:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.932 uVs 13:26:01 Integrated Voltage Measurement... 13:26:10 Voltage Offset Correction: v_off_ini = 16.173 uV, v_off_fin = 37.816 uV 13:26:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.869 uVs 13:26:14 I1X Average and RMS of Measurements VT = -118.523 +- 4.929 uVs I1X = 23.706 +- 0.987 uTm 13:26:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:26:21 Integrated Voltage Measurement... 13:26:30 Voltage Offset Correction: v_off_ini = 29.673 uV, v_off_fin = 30.466 uV 13:26:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.686 uVs 13:26:30 Integrated Voltage Measurement... 13:26:39 Voltage Offset Correction: v_off_ini = 38.740 uV, v_off_fin = 51.495 uV 13:26:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.362 uVs 13:26:39 Integrated Voltage Measurement... 13:26:48 Voltage Offset Correction: v_off_ini = 42.273 uV, v_off_fin = 25.622 uV 13:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.270 uVs 13:26:48 Integrated Voltage Measurement... 13:26:57 Voltage Offset Correction: v_off_ini = 28.775 uV, v_off_fin = 49.753 uV 13:26:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.166 uVs 13:26:57 Integrated Voltage Measurement... 13:27:06 Voltage Offset Correction: v_off_ini = 43.481 uV, v_off_fin = 33.458 uV 13:27:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.584 uVs 13:27:06 Integrated Voltage Measurement... 13:27:15 Voltage Offset Correction: v_off_ini = 38.438 uV, v_off_fin = 56.337 uV 13:27:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.488 uVs 13:27:19 I1Y Average and RMS of Measurements VT = -251.259 +- 4.161 uVs I1Y = -50.252 +- 0.832 uTm 13:27:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:27:24 Integrated Voltage Measurement... 13:27:33 Voltage Offset Correction: v_off_ini = 31.243 uV, v_off_fin = 35.321 uV 13:27:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.444 uVs 13:27:33 Integrated Voltage Measurement... 13:27:42 Voltage Offset Correction: v_off_ini = 32.588 uV, v_off_fin = 49.277 uV 13:27:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.633 uVs 13:27:42 Integrated Voltage Measurement... 13:27:51 Voltage Offset Correction: v_off_ini = 25.084 uV, v_off_fin = 30.768 uV 13:27:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.114 uVs 13:27:51 Integrated Voltage Measurement... 13:28:00 Voltage Offset Correction: v_off_ini = 25.879 uV, v_off_fin = 40.883 uV 13:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.645 uVs 13:28:01 Integrated Voltage Measurement... 13:28:09 Voltage Offset Correction: v_off_ini = 36.488 uV, v_off_fin = 21.032 uV 13:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.027 uVs 13:28:10 Integrated Voltage Measurement... 13:28:19 Voltage Offset Correction: v_off_ini = 23.502 uV, v_off_fin = 41.910 uV 13:28:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.978 uVs 13:28:21 I2X Average and RMS of Measurements VT = -102.973 +- 5.701 uVs I2X = 9.474 +- 0.525 uTm^2 13:28:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:28:26 Integrated Voltage Measurement... 13:28:35 Voltage Offset Correction: v_off_ini = 28.900 uV, v_off_fin = 27.199 uV 13:28:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.100 uVs 13:28:35 Integrated Voltage Measurement... 13:28:44 Voltage Offset Correction: v_off_ini = 25.631 uV, v_off_fin = 31.785 uV 13:28:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.737 uVs 13:28:44 Integrated Voltage Measurement... 13:28:53 Voltage Offset Correction: v_off_ini = 30.743 uV, v_off_fin = 31.139 uV 13:28:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.045 uVs 13:28:53 Integrated Voltage Measurement... 13:29:02 Voltage Offset Correction: v_off_ini = 39.061 uV, v_off_fin = 34.581 uV 13:29:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.168 uVs 13:29:02 Integrated Voltage Measurement... 13:29:11 Voltage Offset Correction: v_off_ini = 38.098 uV, v_off_fin = 36.583 uV 13:29:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.978 uVs 13:29:11 Integrated Voltage Measurement... 13:29:20 Voltage Offset Correction: v_off_ini = 33.815 uV, v_off_fin = 30.616 uV 13:29:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.547 uVs 13:29:23 I2Y Average and RMS of Measurements VT = -297.596 +- 8.358 uVs I2Y = -27.379 +- 0.769 uTm^2 13:29:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:29:31 Integrated Voltage Measurement... 13:29:40 Voltage Offset Correction: v_off_ini = 34.742 uV, v_off_fin = 30.383 uV 13:29:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.178 uVs 13:29:40 Integrated Voltage Measurement... 13:29:49 Voltage Offset Correction: v_off_ini = 44.943 uV, v_off_fin = 53.556 uV 13:29:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.133 uVs 13:29:49 Integrated Voltage Measurement... 13:29:58 Voltage Offset Correction: v_off_ini = 42.746 uV, v_off_fin = 46.825 uV 13:29:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.504 uVs 13:29:58 Integrated Voltage Measurement... 13:30:07 Voltage Offset Correction: v_off_ini = 41.517 uV, v_off_fin = 53.418 uV 13:30:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.860 uVs 13:30:07 Integrated Voltage Measurement... 13:30:16 Voltage Offset Correction: v_off_ini = 47.663 uV, v_off_fin = 48.718 uV 13:30:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.047 uVs 13:30:16 Integrated Voltage Measurement... 13:30:25 Voltage Offset Correction: v_off_ini = 46.481 uV, v_off_fin = 46.055 uV 13:30:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.037 uVs 13:30:29 I1X Average and RMS of Measurements VT = -109.960 +- 1.033 uVs I1X = 21.992 +- 0.207 uTm 13:30:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:30:36 Integrated Voltage Measurement... 13:30:45 Voltage Offset Correction: v_off_ini = 37.033 uV, v_off_fin = 20.008 uV 13:30:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.738 uVs 13:30:45 Integrated Voltage Measurement... 13:30:54 Voltage Offset Correction: v_off_ini = 42.172 uV, v_off_fin = 47.420 uV 13:30:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.893 uVs 13:30:54 Integrated Voltage Measurement... 13:31:03 Voltage Offset Correction: v_off_ini = 49.132 uV, v_off_fin = 31.852 uV 13:31:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.984 uVs 13:31:03 Integrated Voltage Measurement... 13:31:12 Voltage Offset Correction: v_off_ini = 43.093 uV, v_off_fin = 54.959 uV 13:31:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.141 uVs 13:31:12 Integrated Voltage Measurement... 13:31:21 Voltage Offset Correction: v_off_ini = 60.083 uV, v_off_fin = 48.014 uV 13:31:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.766 uVs 13:31:21 Integrated Voltage Measurement... 13:31:30 Voltage Offset Correction: v_off_ini = 56.050 uV, v_off_fin = 57.571 uV 13:31:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.647 uVs 13:31:34 I1Y Average and RMS of Measurements VT = -257.195 +- 4.349 uVs I1Y = -51.439 +- 0.870 uTm 13:31:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:31:39 Integrated Voltage Measurement... 13:31:48 Voltage Offset Correction: v_off_ini = 46.231 uV, v_off_fin = 28.291 uV 13:31:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.691 uVs 13:31:48 Integrated Voltage Measurement... 13:31:57 Voltage Offset Correction: v_off_ini = 25.396 uV, v_off_fin = 36.644 uV 13:31:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.777 uVs 13:31:57 Integrated Voltage Measurement... 13:32:06 Voltage Offset Correction: v_off_ini = 37.428 uV, v_off_fin = 22.976 uV 13:32:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.022 uVs 13:32:06 Integrated Voltage Measurement... 13:32:15 Voltage Offset Correction: v_off_ini = 32.491 uV, v_off_fin = 33.847 uV 13:32:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.411 uVs 13:32:15 Integrated Voltage Measurement... 13:32:24 Voltage Offset Correction: v_off_ini = 33.790 uV, v_off_fin = 29.090 uV 13:32:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.821 uVs 13:32:24 Integrated Voltage Measurement... 13:32:33 Voltage Offset Correction: v_off_ini = 38.468 uV, v_off_fin = 46.772 uV 13:32:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.037 uVs 13:32:36 I2X Average and RMS of Measurements VT = -108.626 +- 9.837 uVs I2X = 9.994 +- 0.905 uTm^2 13:32:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:32:41 Integrated Voltage Measurement... 13:32:50 Voltage Offset Correction: v_off_ini = 29.319 uV, v_off_fin = 28.122 uV 13:32:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.513 uVs 13:32:50 Integrated Voltage Measurement... 13:32:59 Voltage Offset Correction: v_off_ini = 26.834 uV, v_off_fin = 36.740 uV 13:32:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.286 uVs 13:32:59 Integrated Voltage Measurement... 13:33:08 Voltage Offset Correction: v_off_ini = 38.232 uV, v_off_fin = 35.020 uV 13:33:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.228 uVs 13:33:08 Integrated Voltage Measurement... 13:33:17 Voltage Offset Correction: v_off_ini = 17.326 uV, v_off_fin = 21.562 uV 13:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.624 uVs 13:33:17 Integrated Voltage Measurement... 13:33:26 Voltage Offset Correction: v_off_ini = 36.817 uV, v_off_fin = 26.758 uV 13:33:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.193 uVs 13:33:26 Integrated Voltage Measurement... 13:33:35 Voltage Offset Correction: v_off_ini = 24.480 uV, v_off_fin = 27.572 uV 13:33:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.960 uVs 13:33:38 I2Y Average and RMS of Measurements VT = -303.301 +- 3.217 uVs I2Y = -27.904 +- 0.296 uTm^2 13:33:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:46 Integrated Voltage Measurement... 13:33:55 Voltage Offset Correction: v_off_ini = 24.589 uV, v_off_fin = 27.432 uV 13:33:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -135.865 uVs 13:33:55 Integrated Voltage Measurement... 13:34:04 Voltage Offset Correction: v_off_ini = 19.190 uV, v_off_fin = 28.054 uV 13:34:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 110.031 uVs 13:34:04 Integrated Voltage Measurement... 13:34:13 Voltage Offset Correction: v_off_ini = 21.036 uV, v_off_fin = 19.457 uV 13:34:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.182 uVs 13:34:13 Integrated Voltage Measurement... 13:34:22 Voltage Offset Correction: v_off_ini = 23.580 uV, v_off_fin = 19.977 uV 13:34:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.969 uVs 13:34:22 Integrated Voltage Measurement... 13:34:31 Voltage Offset Correction: v_off_ini = 21.179 uV, v_off_fin = 13.386 uV 13:34:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.694 uVs 13:34:31 Integrated Voltage Measurement... 13:34:40 Voltage Offset Correction: v_off_ini = 3.173 uV, v_off_fin = 4.212 uV 13:34:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.108 uVs 13:34:44 I1X Average and RMS of Measurements VT = -118.808 +- 3.646 uVs I1X = 23.763 +- 0.731 uTm 13:34:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:51 Integrated Voltage Measurement... 13:35:00 Voltage Offset Correction: v_off_ini = -6.770 uV, v_off_fin = -13.886 uV 13:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.674 uVs 13:35:00 Integrated Voltage Measurement... 13:35:09 Voltage Offset Correction: v_off_ini = -2.233 uV, v_off_fin = 0.527 uV 13:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.675 uVs 13:35:09 Integrated Voltage Measurement... 13:35:18 Voltage Offset Correction: v_off_ini = 4.793 uV, v_off_fin = -9.922 uV 13:35:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.388 uVs 13:35:18 Integrated Voltage Measurement... 13:35:27 Voltage Offset Correction: v_off_ini = 0.392 uV, v_off_fin = 11.183 uV 13:35:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.848 uVs 13:35:27 Integrated Voltage Measurement... 13:35:36 Voltage Offset Correction: v_off_ini = -2.656 uV, v_off_fin = -18.618 uV 13:35:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.106 uVs 13:35:36 Integrated Voltage Measurement... 13:35:45 Voltage Offset Correction: v_off_ini = 14.362 uV, v_off_fin = 16.526 uV 13:35:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.556 uVs 13:35:49 I1Y Average and RMS of Measurements VT = -261.375 +- 12.622 uVs I1Y = -52.275 +- 2.524 uTm 13:35:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:55 Integrated Voltage Measurement... 13:36:04 Voltage Offset Correction: v_off_ini = 18.288 uV, v_off_fin = -9.065 uV 13:36:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.383 uVs 13:36:04 Integrated Voltage Measurement... 13:36:13 Voltage Offset Correction: v_off_ini = -4.628 uV, v_off_fin = 13.963 uV 13:36:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.719 uVs 13:36:13 Integrated Voltage Measurement... 13:36:22 Voltage Offset Correction: v_off_ini = 7.151 uV, v_off_fin = 8.172 uV 13:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.635 uVs 13:36:22 Integrated Voltage Measurement... 13:36:31 Voltage Offset Correction: v_off_ini = 13.629 uV, v_off_fin = 24.175 uV 13:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.014 uVs 13:36:31 Integrated Voltage Measurement... 13:36:40 Voltage Offset Correction: v_off_ini = 5.792 uV, v_off_fin = -7.047 uV 13:36:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.216 uVs 13:36:40 Integrated Voltage Measurement... 13:36:49 Voltage Offset Correction: v_off_ini = 2.878 uV, v_off_fin = 8.935 uV 13:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.740 uVs 13:36:51 I2X Average and RMS of Measurements VT = -99.451 +- 4.176 uVs I2X = 9.150 +- 0.384 uTm^2 13:36:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:56 Integrated Voltage Measurement... 13:37:05 Voltage Offset Correction: v_off_ini = -5.808 uV, v_off_fin = -9.087 uV 13:37:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.639 uVs 13:37:05 Integrated Voltage Measurement... 13:37:14 Voltage Offset Correction: v_off_ini = -2.014 uV, v_off_fin = 4.657 uV 13:37:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.013 uVs 13:37:14 Integrated Voltage Measurement... 13:37:23 Voltage Offset Correction: v_off_ini = 8.410 uV, v_off_fin = 8.921 uV 13:37:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.292 uVs 13:37:23 Integrated Voltage Measurement... 13:37:32 Voltage Offset Correction: v_off_ini = 3.563 uV, v_off_fin = 12.719 uV 13:37:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.750 uVs 13:37:32 Integrated Voltage Measurement... 13:37:41 Voltage Offset Correction: v_off_ini = 10.006 uV, v_off_fin = -1.775 uV 13:37:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.814 uVs 13:37:42 Integrated Voltage Measurement... 13:37:50 Voltage Offset Correction: v_off_ini = 5.739 uV, v_off_fin = 10.689 uV 13:37:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.573 uVs 13:37:53 I2Y Average and RMS of Measurements VT = -305.180 +- 5.889 uVs I2Y = -28.077 +- 0.542 uTm^2 13:37:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:38:01 Integrated Voltage Measurement... 13:38:10 Voltage Offset Correction: v_off_ini = -9.959 uV, v_off_fin = -1.570 uV 13:38:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.565 uVs 13:38:10 Integrated Voltage Measurement... 13:38:19 Voltage Offset Correction: v_off_ini = -1.726 uV, v_off_fin = 7.395 uV 13:38:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 112.344 uVs 13:38:19 Integrated Voltage Measurement... 13:38:28 Voltage Offset Correction: v_off_ini = 9.801 uV, v_off_fin = 4.306 uV 13:38:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.407 uVs 13:38:28 Integrated Voltage Measurement... 13:38:37 Voltage Offset Correction: v_off_ini = 10.464 uV, v_off_fin = 16.123 uV 13:38:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.501 uVs 13:38:37 Integrated Voltage Measurement... 13:38:46 Voltage Offset Correction: v_off_ini = 4.161 uV, v_off_fin = -3.244 uV 13:38:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.022 uVs 13:38:46 Integrated Voltage Measurement... 13:38:55 Voltage Offset Correction: v_off_ini = 5.082 uV, v_off_fin = -12.929 uV 13:38:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.576 uVs 13:39:00 I1X Average and RMS of Measurements VT = -104.069 +- 7.154 uVs I1X = 20.815 +- 1.430 uTm 13:39:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:39:06 Integrated Voltage Measurement... 13:39:15 Voltage Offset Correction: v_off_ini = -10.505 uV, v_off_fin = -9.768 uV 13:39:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.588 uVs 13:39:15 Integrated Voltage Measurement... 13:39:24 Voltage Offset Correction: v_off_ini = -20.086 uV, v_off_fin = -0.414 uV 13:39:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.026 uVs 13:39:24 Integrated Voltage Measurement... 13:39:33 Voltage Offset Correction: v_off_ini = -15.884 uV, v_off_fin = -23.063 uV 13:39:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.302 uVs 13:39:33 Integrated Voltage Measurement... 13:39:42 Voltage Offset Correction: v_off_ini = -6.643 uV, v_off_fin = -0.765 uV 13:39:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.015 uVs 13:39:42 Integrated Voltage Measurement... 13:39:51 Voltage Offset Correction: v_off_ini = -3.736 uV, v_off_fin = -20.188 uV 13:39:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.886 uVs 13:39:51 Integrated Voltage Measurement... 13:40:00 Voltage Offset Correction: v_off_ini = -24.071 uV, v_off_fin = -15.493 uV 13:40:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.204 uVs 13:40:05 I1Y Average and RMS of Measurements VT = -257.670 +- 0.302 uVs I1Y = -51.535 +- 0.060 uTm 13:40:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:40:10 Integrated Voltage Measurement... 13:40:19 Voltage Offset Correction: v_off_ini = -21.715 uV, v_off_fin = -28.675 uV 13:40:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.725 uVs 13:40:19 Integrated Voltage Measurement... 13:40:28 Voltage Offset Correction: v_off_ini = -22.647 uV, v_off_fin = -14.426 uV 13:40:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.339 uVs 13:40:28 Integrated Voltage Measurement... 13:40:37 Voltage Offset Correction: v_off_ini = -29.095 uV, v_off_fin = -41.510 uV 13:40:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.968 uVs 13:40:37 Integrated Voltage Measurement... 13:40:46 Voltage Offset Correction: v_off_ini = -25.276 uV, v_off_fin = -14.527 uV 13:40:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.823 uVs 13:40:46 Integrated Voltage Measurement... 13:40:55 Voltage Offset Correction: v_off_ini = -24.415 uV, v_off_fin = -32.092 uV 13:40:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.010 uVs 13:40:55 Integrated Voltage Measurement... 13:41:04 Voltage Offset Correction: v_off_ini = -33.252 uV, v_off_fin = -14.295 uV 13:41:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.501 uVs 13:41:06 I2X Average and RMS of Measurements VT = -85.894 +- 4.737 uVs I2X = 7.902 +- 0.436 uTm^2 13:41:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:41:12 Integrated Voltage Measurement... 13:41:21 Voltage Offset Correction: v_off_ini = -21.982 uV, v_off_fin = -21.510 uV 13:41:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.949 uVs 13:41:21 Integrated Voltage Measurement... 13:41:30 Voltage Offset Correction: v_off_ini = -18.838 uV, v_off_fin = -28.833 uV 13:41:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.985 uVs 13:41:30 Integrated Voltage Measurement... 13:41:39 Voltage Offset Correction: v_off_ini = -26.390 uV, v_off_fin = -32.442 uV 13:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.236 uVs 13:41:39 Integrated Voltage Measurement... 13:41:48 Voltage Offset Correction: v_off_ini = -28.167 uV, v_off_fin = -23.913 uV 13:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.504 uVs 13:41:48 Integrated Voltage Measurement... 13:41:57 Voltage Offset Correction: v_off_ini = -27.855 uV, v_off_fin = -27.267 uV 13:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.747 uVs 13:41:57 Integrated Voltage Measurement... 13:42:06 Voltage Offset Correction: v_off_ini = -20.473 uV, v_off_fin = -9.932 uV 13:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.892 uVs 13:42:08 I2Y Average and RMS of Measurements VT = -308.886 +- 4.862 uVs I2Y = -28.417 +- 0.447 uTm^2 13:42:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:42:17 Integrated Voltage Measurement... 13:42:25 Voltage Offset Correction: v_off_ini = -43.239 uV, v_off_fin = -26.949 uV 13:42:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.694 uVs 13:42:26 Integrated Voltage Measurement... 13:42:35 Voltage Offset Correction: v_off_ini = -16.203 uV, v_off_fin = -12.400 uV 13:42:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.736 uVs 13:42:35 Integrated Voltage Measurement... 13:42:44 Voltage Offset Correction: v_off_ini = -23.186 uV, v_off_fin = -19.910 uV 13:42:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.388 uVs 13:42:44 Integrated Voltage Measurement... 13:42:53 Voltage Offset Correction: v_off_ini = -25.425 uV, v_off_fin = -26.069 uV 13:42:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.892 uVs 13:42:53 Integrated Voltage Measurement... 13:43:02 Voltage Offset Correction: v_off_ini = -23.165 uV, v_off_fin = -22.755 uV 13:43:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.355 uVs 13:43:02 Integrated Voltage Measurement... 13:43:11 Voltage Offset Correction: v_off_ini = -23.486 uV, v_off_fin = -19.016 uV 13:43:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.142 uVs 13:43:15 I1X Average and RMS of Measurements VT = -79.034 +- 0.876 uVs I1X = 15.807 +- 0.175 uTm 13:43:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:43:22 Integrated Voltage Measurement... 13:43:31 Voltage Offset Correction: v_off_ini = -21.320 uV, v_off_fin = -36.226 uV 13:43:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.411 uVs 13:43:31 Integrated Voltage Measurement... 13:43:40 Voltage Offset Correction: v_off_ini = -14.282 uV, v_off_fin = -2.024 uV 13:43:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.860 uVs 13:43:40 Integrated Voltage Measurement... 13:43:49 Voltage Offset Correction: v_off_ini = -17.762 uV, v_off_fin = -27.253 uV 13:43:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.185 uVs 13:43:49 Integrated Voltage Measurement... 13:43:58 Voltage Offset Correction: v_off_ini = -13.195 uV, v_off_fin = -0.878 uV 13:43:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.900 uVs 13:43:58 Integrated Voltage Measurement... 13:44:07 Voltage Offset Correction: v_off_ini = -19.322 uV, v_off_fin = -40.896 uV 13:44:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.415 uVs 13:44:07 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = -21.654 uV, v_off_fin = -6.326 uV 13:44:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.238 uVs 13:44:20 I1Y Average and RMS of Measurements VT = -255.335 +- 1.532 uVs I1Y = -51.067 +- 0.306 uTm 13:44:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:44:25 Integrated Voltage Measurement... 13:44:34 Voltage Offset Correction: v_off_ini = -24.540 uV, v_off_fin = -30.287 uV 13:44:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.143 uVs 13:44:34 Integrated Voltage Measurement... 13:44:43 Voltage Offset Correction: v_off_ini = -17.127 uV, v_off_fin = -4.728 uV 13:44:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.192 uVs 13:44:43 Integrated Voltage Measurement... 13:44:52 Voltage Offset Correction: v_off_ini = -20.652 uV, v_off_fin = -16.057 uV 13:44:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.964 uVs 13:44:52 Integrated Voltage Measurement... 13:45:01 Voltage Offset Correction: v_off_ini = -4.453 uV, v_off_fin = -4.162 uV 13:45:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.210 uVs 13:45:01 Integrated Voltage Measurement... 13:45:10 Voltage Offset Correction: v_off_ini = 9.769 uV, v_off_fin = -8.394 uV 13:45:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.859 uVs 13:45:10 Integrated Voltage Measurement... 13:45:19 Voltage Offset Correction: v_off_ini = -10.805 uV, v_off_fin = 7.070 uV 13:45:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.815 uVs 13:45:22 I2X Average and RMS of Measurements VT = -61.030 +- 6.022 uVs I2X = 5.615 +- 0.554 uTm^2 13:45:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:45:27 Integrated Voltage Measurement... 13:45:36 Voltage Offset Correction: v_off_ini = -16.342 uV, v_off_fin = -10.426 uV 13:45:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.737 uVs 13:45:36 Integrated Voltage Measurement... 13:45:45 Voltage Offset Correction: v_off_ini = -18.914 uV, v_off_fin = -19.687 uV 13:45:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.426 uVs 13:45:45 Integrated Voltage Measurement... 13:45:54 Voltage Offset Correction: v_off_ini = -15.175 uV, v_off_fin = -16.492 uV 13:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.936 uVs 13:45:54 Integrated Voltage Measurement... 13:46:03 Voltage Offset Correction: v_off_ini = 0.854 uV, v_off_fin = -8.165 uV 13:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.715 uVs 13:46:03 Integrated Voltage Measurement... 13:46:12 Voltage Offset Correction: v_off_ini = -12.584 uV, v_off_fin = -10.555 uV 13:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.809 uVs 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = 1.758 uV, v_off_fin = -1.059 uV 13:46:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.318 uVs 13:46:23 I2Y Average and RMS of Measurements VT = -313.490 +- 13.851 uVs I2Y = -28.841 +- 1.274 uTm^2 13:46:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:46:45 Integrated Voltage Measurement... 13:46:54 Voltage Offset Correction: v_off_ini = 6.007 uV, v_off_fin = -0.090 uV 13:46:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.819 uVs 13:46:54 Integrated Voltage Measurement... 13:47:03 Voltage Offset Correction: v_off_ini = 1.623 uV, v_off_fin = 8.529 uV 13:47:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.193 uVs 13:47:03 Integrated Voltage Measurement... 13:47:12 Voltage Offset Correction: v_off_ini = 9.610 uV, v_off_fin = 6.140 uV 13:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.009 uVs 13:47:12 Integrated Voltage Measurement... 13:47:21 Voltage Offset Correction: v_off_ini = 13.384 uV, v_off_fin = 16.007 uV 13:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.959 uVs 13:47:21 Integrated Voltage Measurement... 13:47:30 Voltage Offset Correction: v_off_ini = 5.455 uV, v_off_fin = 4.315 uV 13:47:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.810 uVs 13:47:30 Integrated Voltage Measurement... 13:47:39 Voltage Offset Correction: v_off_ini = 5.016 uV, v_off_fin = 12.235 uV 13:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.764 uVs 13:47:43 I1X Average and RMS of Measurements VT = -127.592 +- 1.709 uVs I1X = 25.519 +- 0.341 uTm 13:47:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:47:50 Integrated Voltage Measurement... 13:47:59 Voltage Offset Correction: v_off_ini = -5.278 uV, v_off_fin = -2.374 uV 13:47:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.155 uVs 13:47:59 Integrated Voltage Measurement... 13:48:08 Voltage Offset Correction: v_off_ini = 17.988 uV, v_off_fin = 19.196 uV 13:48:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.987 uVs 13:48:08 Integrated Voltage Measurement... 13:48:17 Voltage Offset Correction: v_off_ini = 21.613 uV, v_off_fin = 11.887 uV 13:48:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.622 uVs 13:48:17 Integrated Voltage Measurement... 13:48:26 Voltage Offset Correction: v_off_ini = 11.937 uV, v_off_fin = 22.024 uV 13:48:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.399 uVs 13:48:26 Integrated Voltage Measurement... 13:48:35 Voltage Offset Correction: v_off_ini = 20.640 uV, v_off_fin = 5.425 uV 13:48:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.250 uVs 13:48:35 Integrated Voltage Measurement... 13:48:44 Voltage Offset Correction: v_off_ini = 9.857 uV, v_off_fin = 16.914 uV 13:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.897 uVs 13:48:48 I1Y Average and RMS of Measurements VT = -217.051 +- 6.706 uVs I1Y = -43.410 +- 1.341 uTm 13:48:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:48:56 Integrated Voltage Measurement... 13:49:05 Voltage Offset Correction: v_off_ini = 26.007 uV, v_off_fin = 3.908 uV 13:49:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.188 uVs 13:49:05 Integrated Voltage Measurement... 13:49:14 Voltage Offset Correction: v_off_ini = 17.563 uV, v_off_fin = 17.377 uV 13:49:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.805 uVs 13:49:14 Integrated Voltage Measurement... 13:49:23 Voltage Offset Correction: v_off_ini = 9.990 uV, v_off_fin = 13.726 uV 13:49:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.889 uVs 13:49:23 Integrated Voltage Measurement... 13:49:32 Voltage Offset Correction: v_off_ini = 22.648 uV, v_off_fin = 26.852 uV 13:49:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.234 uVs 13:49:32 Integrated Voltage Measurement... 13:49:41 Voltage Offset Correction: v_off_ini = 25.488 uV, v_off_fin = 17.244 uV 13:49:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.031 uVs 13:49:41 Integrated Voltage Measurement... 13:49:50 Voltage Offset Correction: v_off_ini = 22.639 uV, v_off_fin = 29.532 uV 13:49:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.671 uVs 13:49:52 I2X Average and RMS of Measurements VT = -112.970 +- 2.314 uVs I2X = 10.393 +- 0.213 uTm^2 13:49:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:50:00 Integrated Voltage Measurement... 13:50:09 Voltage Offset Correction: v_off_ini = 23.445 uV, v_off_fin = 22.039 uV 13:50:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.751 uVs 13:50:09 Integrated Voltage Measurement... 13:50:18 Voltage Offset Correction: v_off_ini = 27.455 uV, v_off_fin = 28.483 uV 13:50:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.855 uVs 13:50:18 Integrated Voltage Measurement... 13:50:27 Voltage Offset Correction: v_off_ini = 33.804 uV, v_off_fin = 30.140 uV 13:50:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.748 uVs 13:50:27 Integrated Voltage Measurement... 13:50:36 Voltage Offset Correction: v_off_ini = 36.209 uV, v_off_fin = 35.051 uV 13:50:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.324 uVs 13:50:36 Integrated Voltage Measurement... 13:50:45 Voltage Offset Correction: v_off_ini = 49.043 uV, v_off_fin = 47.947 uV 13:50:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.172 uVs 13:50:45 Integrated Voltage Measurement... 13:50:54 Voltage Offset Correction: v_off_ini = 39.379 uV, v_off_fin = 30.585 uV 13:50:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.737 uVs 13:50:57 I2Y Average and RMS of Measurements VT = -257.265 +- 7.056 uVs I2Y = -23.668 +- 0.649 uTm^2 13:51:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:51:06 Integrated Voltage Measurement... 13:51:15 Voltage Offset Correction: v_off_ini = 24.789 uV, v_off_fin = 5.517 uV 13:51:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.403 uVs 13:51:15 Integrated Voltage Measurement... 13:51:24 Voltage Offset Correction: v_off_ini = 24.571 uV, v_off_fin = 19.279 uV 13:51:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.586 uVs 13:51:24 Integrated Voltage Measurement... 13:51:33 Voltage Offset Correction: v_off_ini = 2.762 uV, v_off_fin = 2.603 uV 13:51:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.351 uVs 13:51:33 Integrated Voltage Measurement... 13:51:42 Voltage Offset Correction: v_off_ini = 9.394 uV, v_off_fin = 12.194 uV 13:51:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.285 uVs 13:51:42 Integrated Voltage Measurement... 13:51:51 Voltage Offset Correction: v_off_ini = 6.805 uV, v_off_fin = -2.231 uV 13:51:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.493 uVs 13:51:51 Integrated Voltage Measurement... 13:52:00 Voltage Offset Correction: v_off_ini = 1.186 uV, v_off_fin = 16.473 uV 13:52:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.172 uVs 13:52:04 I1X Average and RMS of Measurements VT = -127.715 +- 9.900 uVs I1X = 25.543 +- 1.980 uTm 13:52:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:52:11 Integrated Voltage Measurement... 13:52:20 Voltage Offset Correction: v_off_ini = 17.981 uV, v_off_fin = 3.342 uV 13:52:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.714 uVs 13:52:20 Integrated Voltage Measurement... 13:52:29 Voltage Offset Correction: v_off_ini = 13.260 uV, v_off_fin = 22.427 uV 13:52:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.556 uVs 13:52:29 Integrated Voltage Measurement... 13:52:38 Voltage Offset Correction: v_off_ini = 3.056 uV, v_off_fin = -11.584 uV 13:52:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.297 uVs 13:52:38 Integrated Voltage Measurement... 13:52:47 Voltage Offset Correction: v_off_ini = 6.803 uV, v_off_fin = 17.309 uV 13:52:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.060 uVs 13:52:47 Integrated Voltage Measurement... 13:52:56 Voltage Offset Correction: v_off_ini = -13.069 uV, v_off_fin = -14.146 uV 13:52:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.045 uVs 13:52:56 Integrated Voltage Measurement... 13:53:05 Voltage Offset Correction: v_off_ini = -10.270 uV, v_off_fin = -13.922 uV 13:53:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.611 uVs 13:53:09 I1Y Average and RMS of Measurements VT = -242.547 +- 3.374 uVs I1Y = -48.509 +- 0.675 uTm 13:53:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:53:17 Integrated Voltage Measurement... 13:53:26 Voltage Offset Correction: v_off_ini = -21.766 uV, v_off_fin = -27.820 uV 13:53:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.866 uVs 13:53:26 Integrated Voltage Measurement... 13:53:35 Voltage Offset Correction: v_off_ini = -31.970 uV, v_off_fin = -18.048 uV 13:53:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.897 uVs 13:53:35 Integrated Voltage Measurement... 13:53:44 Voltage Offset Correction: v_off_ini = -10.072 uV, v_off_fin = -31.828 uV 13:53:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.825 uVs 13:53:44 Integrated Voltage Measurement... 13:53:53 Voltage Offset Correction: v_off_ini = -6.498 uV, v_off_fin = -4.638 uV 13:53:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.101 uVs 13:53:53 Integrated Voltage Measurement... 13:54:02 Voltage Offset Correction: v_off_ini = -15.410 uV, v_off_fin = -16.886 uV 13:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.390 uVs 13:54:02 Integrated Voltage Measurement... 13:54:11 Voltage Offset Correction: v_off_ini = -9.436 uV, v_off_fin = 3.041 uV 13:54:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.431 uVs 13:54:13 I2X Average and RMS of Measurements VT = -109.585 +- 0.650 uVs I2X = 10.082 +- 0.060 uTm^2 13:54:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:54:21 Integrated Voltage Measurement... 13:54:30 Voltage Offset Correction: v_off_ini = -28.633 uV, v_off_fin = -16.984 uV 13:54:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.229 uVs 13:54:30 Integrated Voltage Measurement... 13:54:39 Voltage Offset Correction: v_off_ini = -14.341 uV, v_off_fin = -23.361 uV 13:54:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.449 uVs 13:54:39 Integrated Voltage Measurement... 13:54:48 Voltage Offset Correction: v_off_ini = -25.967 uV, v_off_fin = -19.678 uV 13:54:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -281.642 uVs 13:54:48 Integrated Voltage Measurement... 13:54:57 Voltage Offset Correction: v_off_ini = -18.041 uV, v_off_fin = -21.050 uV 13:54:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.484 uVs 13:54:57 Integrated Voltage Measurement... 13:55:06 Voltage Offset Correction: v_off_ini = -34.867 uV, v_off_fin = -27.285 uV 13:55:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.042 uVs 13:55:06 Integrated Voltage Measurement... 13:55:15 Voltage Offset Correction: v_off_ini = -12.587 uV, v_off_fin = -19.175 uV 13:55:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.970 uVs 13:55:18 I2Y Average and RMS of Measurements VT = -283.969 +- 3.282 uVs I2Y = -26.126 +- 0.302 uTm^2 13:55:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:27 Integrated Voltage Measurement... 13:55:36 Voltage Offset Correction: v_off_ini = -14.114 uV, v_off_fin = -13.562 uV 13:55:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.403 uVs 13:55:36 Integrated Voltage Measurement... 13:55:45 Voltage Offset Correction: v_off_ini = -5.730 uV, v_off_fin = -9.087 uV 13:55:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.031 uVs 13:55:45 Integrated Voltage Measurement... 13:55:54 Voltage Offset Correction: v_off_ini = 4.081 uV, v_off_fin = -12.697 uV 13:55:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.909 uVs 13:55:54 Integrated Voltage Measurement... 13:56:03 Voltage Offset Correction: v_off_ini = -25.919 uV, v_off_fin = -27.284 uV 13:56:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.286 uVs 13:56:03 Integrated Voltage Measurement... 13:56:12 Voltage Offset Correction: v_off_ini = -28.545 uV, v_off_fin = -30.612 uV 13:56:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.250 uVs 13:56:12 Integrated Voltage Measurement... 13:56:21 Voltage Offset Correction: v_off_ini = -20.694 uV, v_off_fin = -17.700 uV 13:56:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.310 uVs 13:56:25 I1X Average and RMS of Measurements VT = -126.698 +- 8.836 uVs I1X = 25.341 +- 1.768 uTm 13:56:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:32 Integrated Voltage Measurement... 13:56:41 Voltage Offset Correction: v_off_ini = -16.246 uV, v_off_fin = -25.797 uV 13:56:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.674 uVs 13:56:41 Integrated Voltage Measurement... 13:56:50 Voltage Offset Correction: v_off_ini = -15.909 uV, v_off_fin = -14.587 uV 13:56:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.562 uVs 13:56:50 Integrated Voltage Measurement... 13:56:59 Voltage Offset Correction: v_off_ini = -19.127 uV, v_off_fin = -28.016 uV 13:56:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.654 uVs 13:56:59 Integrated Voltage Measurement... 13:57:08 Voltage Offset Correction: v_off_ini = -5.596 uV, v_off_fin = -8.644 uV 13:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.950 uVs 13:57:08 Integrated Voltage Measurement... 13:57:17 Voltage Offset Correction: v_off_ini = -16.145 uV, v_off_fin = -35.706 uV 13:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.366 uVs 13:57:17 Integrated Voltage Measurement... 13:57:26 Voltage Offset Correction: v_off_ini = -32.483 uV, v_off_fin = -20.442 uV 13:57:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.549 uVs 13:57:30 I1Y Average and RMS of Measurements VT = -259.126 +- 5.463 uVs I1Y = -51.825 +- 1.093 uTm 13:57:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:38 Integrated Voltage Measurement... 13:57:47 Voltage Offset Correction: v_off_ini = -22.718 uV, v_off_fin = -38.772 uV 13:57:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.283 uVs 13:57:47 Integrated Voltage Measurement... 13:57:56 Voltage Offset Correction: v_off_ini = -33.813 uV, v_off_fin = -15.999 uV 13:57:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.724 uVs 13:57:56 Integrated Voltage Measurement... 13:58:05 Voltage Offset Correction: v_off_ini = -21.486 uV, v_off_fin = -24.488 uV 13:58:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -116.810 uVs 13:58:05 Integrated Voltage Measurement... 13:58:14 Voltage Offset Correction: v_off_ini = -35.989 uV, v_off_fin = -14.428 uV 13:58:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.088 uVs 13:58:14 Integrated Voltage Measurement... 13:58:23 Voltage Offset Correction: v_off_ini = -30.269 uV, v_off_fin = -32.769 uV 13:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.434 uVs 13:58:23 Integrated Voltage Measurement... 13:58:32 Voltage Offset Correction: v_off_ini = -21.804 uV, v_off_fin = -11.502 uV 13:58:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.145 uVs 13:58:34 I2X Average and RMS of Measurements VT = -119.081 +- 2.311 uVs I2X = 10.956 +- 0.213 uTm^2 13:58:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:42 Integrated Voltage Measurement... 13:58:51 Voltage Offset Correction: v_off_ini = -11.255 uV, v_off_fin = -18.972 uV 13:58:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.142 uVs 13:58:51 Integrated Voltage Measurement... 13:59:00 Voltage Offset Correction: v_off_ini = -22.368 uV, v_off_fin = -26.803 uV 13:59:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.226 uVs 13:59:00 Integrated Voltage Measurement... 13:59:09 Voltage Offset Correction: v_off_ini = -14.482 uV, v_off_fin = -25.635 uV 13:59:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.351 uVs 13:59:09 Integrated Voltage Measurement... 13:59:18 Voltage Offset Correction: v_off_ini = -24.862 uV, v_off_fin = -17.010 uV 13:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.337 uVs 13:59:18 Integrated Voltage Measurement... 13:59:27 Voltage Offset Correction: v_off_ini = -21.098 uV, v_off_fin = -28.110 uV 13:59:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.071 uVs 13:59:27 Integrated Voltage Measurement... 13:59:36 Voltage Offset Correction: v_off_ini = -9.361 uV, v_off_fin = -5.843 uV 13:59:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.143 uVs 13:59:39 I2Y Average and RMS of Measurements VT = -303.045 +- 9.916 uVs I2Y = -27.880 +- 0.912 uTm^2 13:59:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:59:48 Integrated Voltage Measurement... 13:59:57 Voltage Offset Correction: v_off_ini = -17.904 uV, v_off_fin = -8.614 uV 13:59:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.055 uVs 13:59:57 Integrated Voltage Measurement... 14:00:06 Voltage Offset Correction: v_off_ini = 0.735 uV, v_off_fin = 11.983 uV 14:00:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.252 uVs 14:00:06 Integrated Voltage Measurement... 14:00:15 Voltage Offset Correction: v_off_ini = 3.233 uV, v_off_fin = -6.185 uV 14:00:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.221 uVs 14:00:15 Integrated Voltage Measurement... 14:00:24 Voltage Offset Correction: v_off_ini = 1.470 uV, v_off_fin = 12.233 uV 14:00:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.991 uVs 14:00:24 Integrated Voltage Measurement... 14:00:33 Voltage Offset Correction: v_off_ini = 10.410 uV, v_off_fin = 4.210 uV 14:00:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.791 uVs 14:00:33 Integrated Voltage Measurement... 14:00:42 Voltage Offset Correction: v_off_ini = 0.123 uV, v_off_fin = 2.273 uV 14:00:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.602 uVs 14:00:46 I1X Average and RMS of Measurements VT = -138.985 +- 8.646 uVs I1X = 27.798 +- 1.729 uTm 14:00:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:00:53 Integrated Voltage Measurement... 14:01:02 Voltage Offset Correction: v_off_ini = 0.288 uV, v_off_fin = -16.053 uV 14:01:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -300.359 uVs 14:01:02 Integrated Voltage Measurement... 14:01:11 Voltage Offset Correction: v_off_ini = -6.879 uV, v_off_fin = 3.202 uV 14:01:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 298.905 uVs 14:01:11 Integrated Voltage Measurement... 14:01:20 Voltage Offset Correction: v_off_ini = -0.522 uV, v_off_fin = -16.773 uV 14:01:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.092 uVs 14:01:20 Integrated Voltage Measurement... 14:01:29 Voltage Offset Correction: v_off_ini = -5.267 uV, v_off_fin = -2.780 uV 14:01:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.124 uVs 14:01:29 Integrated Voltage Measurement... 14:01:38 Voltage Offset Correction: v_off_ini = -22.529 uV, v_off_fin = -35.745 uV 14:01:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.565 uVs 14:01:38 Integrated Voltage Measurement... 14:01:47 Voltage Offset Correction: v_off_ini = -7.842 uV, v_off_fin = -14.662 uV 14:01:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.773 uVs 14:01:51 I1Y Average and RMS of Measurements VT = -290.636 +- 7.358 uVs I1Y = -58.128 +- 1.473 uTm 14:01:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:01:59 Integrated Voltage Measurement... 14:02:08 Voltage Offset Correction: v_off_ini = -22.941 uV, v_off_fin = -35.008 uV 14:02:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.132 uVs 14:02:08 Integrated Voltage Measurement... 14:02:17 Voltage Offset Correction: v_off_ini = -20.903 uV, v_off_fin = -15.369 uV 14:02:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.434 uVs 14:02:17 Integrated Voltage Measurement... 14:02:26 Voltage Offset Correction: v_off_ini = -23.445 uV, v_off_fin = -36.125 uV 14:02:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.710 uVs 14:02:26 Integrated Voltage Measurement... 14:02:35 Voltage Offset Correction: v_off_ini = -42.964 uV, v_off_fin = -25.113 uV 14:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.504 uVs 14:02:35 Integrated Voltage Measurement... 14:02:44 Voltage Offset Correction: v_off_ini = -43.319 uV, v_off_fin = -39.160 uV 14:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.314 uVs 14:02:44 Integrated Voltage Measurement... 14:02:53 Voltage Offset Correction: v_off_ini = -39.778 uV, v_off_fin = -36.258 uV 14:02:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.408 uVs 14:02:55 I2X Average and RMS of Measurements VT = -121.084 +- 6.596 uVs I2X = 11.140 +- 0.607 uTm^2 14:03:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:03:03 Integrated Voltage Measurement... 14:03:12 Voltage Offset Correction: v_off_ini = -40.229 uV, v_off_fin = -46.632 uV 14:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.390 uVs 14:03:12 Integrated Voltage Measurement... 14:03:21 Voltage Offset Correction: v_off_ini = -49.711 uV, v_off_fin = -50.274 uV 14:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.010 uVs 14:03:21 Integrated Voltage Measurement... 14:03:30 Voltage Offset Correction: v_off_ini = -48.735 uV, v_off_fin = -59.203 uV 14:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.952 uVs 14:03:30 Integrated Voltage Measurement... 14:03:39 Voltage Offset Correction: v_off_ini = -46.414 uV, v_off_fin = -32.834 uV 14:03:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 316.741 uVs 14:03:39 Integrated Voltage Measurement... 14:03:48 Voltage Offset Correction: v_off_ini = -34.186 uV, v_off_fin = -43.311 uV 14:03:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.982 uVs 14:03:48 Integrated Voltage Measurement... 14:03:57 Voltage Offset Correction: v_off_ini = -35.565 uV, v_off_fin = -33.201 uV 14:03:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.991 uVs 14:04:00 I2Y Average and RMS of Measurements VT = -325.344 +- 5.446 uVs I2Y = -29.932 +- 0.501 uTm^2 14:04:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:04:09 Integrated Voltage Measurement... 14:04:18 Voltage Offset Correction: v_off_ini = -21.461 uV, v_off_fin = -20.225 uV 14:04:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.949 uVs 14:04:18 Integrated Voltage Measurement... 14:04:27 Voltage Offset Correction: v_off_ini = -15.111 uV, v_off_fin = -6.860 uV 14:04:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.957 uVs 14:04:27 Integrated Voltage Measurement... 14:04:36 Voltage Offset Correction: v_off_ini = -18.778 uV, v_off_fin = -33.966 uV 14:04:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.813 uVs 14:04:36 Integrated Voltage Measurement... 14:04:45 Voltage Offset Correction: v_off_ini = -32.258 uV, v_off_fin = -32.067 uV 14:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.247 uVs 14:04:45 Integrated Voltage Measurement... 14:04:54 Voltage Offset Correction: v_off_ini = -18.844 uV, v_off_fin = -27.570 uV 14:04:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.391 uVs 14:04:54 Integrated Voltage Measurement... 14:05:03 Voltage Offset Correction: v_off_ini = -26.243 uV, v_off_fin = -17.127 uV 14:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 132.829 uVs 14:05:07 I1X Average and RMS of Measurements VT = -135.531 +- 3.006 uVs I1X = 27.108 +- 0.602 uTm 14:05:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:05:14 Integrated Voltage Measurement... 14:05:23 Voltage Offset Correction: v_off_ini = -20.478 uV, v_off_fin = -35.442 uV 14:05:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -294.527 uVs 14:05:23 Integrated Voltage Measurement... 14:05:32 Voltage Offset Correction: v_off_ini = -15.090 uV, v_off_fin = -11.069 uV 14:05:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.688 uVs 14:05:32 Integrated Voltage Measurement... 14:05:41 Voltage Offset Correction: v_off_ini = -28.881 uV, v_off_fin = -56.483 uV 14:05:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.928 uVs 14:05:41 Integrated Voltage Measurement... 14:05:50 Voltage Offset Correction: v_off_ini = -44.468 uV, v_off_fin = -15.405 uV 14:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 299.337 uVs 14:05:50 Integrated Voltage Measurement... 14:05:59 Voltage Offset Correction: v_off_ini = -28.186 uV, v_off_fin = -39.072 uV 14:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -300.047 uVs 14:05:59 Integrated Voltage Measurement... 14:06:08 Voltage Offset Correction: v_off_ini = -21.425 uV, v_off_fin = -14.839 uV 14:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 304.386 uVs 14:06:12 I1Y Average and RMS of Measurements VT = -296.985 +- 4.134 uVs I1Y = -59.397 +- 0.827 uTm 14:06:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:06:20 Integrated Voltage Measurement... 14:06:29 Voltage Offset Correction: v_off_ini = -30.991 uV, v_off_fin = -37.526 uV 14:06:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.700 uVs 14:06:29 Integrated Voltage Measurement... 14:06:38 Voltage Offset Correction: v_off_ini = -26.995 uV, v_off_fin = -27.239 uV 14:06:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.794 uVs 14:06:38 Integrated Voltage Measurement... 14:06:47 Voltage Offset Correction: v_off_ini = -34.897 uV, v_off_fin = -49.887 uV 14:06:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.497 uVs 14:06:47 Integrated Voltage Measurement... 14:06:56 Voltage Offset Correction: v_off_ini = -34.530 uV, v_off_fin = -32.356 uV 14:06:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.430 uVs 14:06:56 Integrated Voltage Measurement... 14:07:05 Voltage Offset Correction: v_off_ini = -43.944 uV, v_off_fin = -42.544 uV 14:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.686 uVs 14:07:05 Integrated Voltage Measurement... 14:07:14 Voltage Offset Correction: v_off_ini = -39.829 uV, v_off_fin = -20.371 uV 14:07:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.908 uVs 14:07:16 I2X Average and RMS of Measurements VT = -131.503 +- 6.554 uVs I2X = 12.098 +- 0.603 uTm^2 14:07:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:07:24 Integrated Voltage Measurement... 14:07:33 Voltage Offset Correction: v_off_ini = -35.601 uV, v_off_fin = -32.938 uV 14:07:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.560 uVs 14:07:33 Integrated Voltage Measurement... 14:07:42 Voltage Offset Correction: v_off_ini = -34.771 uV, v_off_fin = -23.955 uV 14:07:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.404 uVs 14:07:42 Integrated Voltage Measurement... 14:07:51 Voltage Offset Correction: v_off_ini = -29.625 uV, v_off_fin = -31.092 uV 14:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -350.303 uVs 14:07:51 Integrated Voltage Measurement... 14:08:00 Voltage Offset Correction: v_off_ini = -25.820 uV, v_off_fin = -28.246 uV 14:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.364 uVs 14:08:00 Integrated Voltage Measurement... 14:08:09 Voltage Offset Correction: v_off_ini = -16.141 uV, v_off_fin = -35.657 uV 14:08:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.401 uVs 14:08:09 Integrated Voltage Measurement... 14:08:18 Voltage Offset Correction: v_off_ini = -22.165 uV, v_off_fin = -30.874 uV 14:08:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.475 uVs 14:08:21 I2Y Average and RMS of Measurements VT = -352.418 +- 2.975 uVs I2Y = -32.422 +- 0.274 uTm^2 14:08:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:08:33 Integrated Voltage Measurement... 14:08:42 Voltage Offset Correction: v_off_ini = -13.213 uV, v_off_fin = -18.893 uV 14:08:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.727 uVs 14:08:42 Integrated Voltage Measurement... 14:08:51 Voltage Offset Correction: v_off_ini = -16.248 uV, v_off_fin = -24.633 uV 14:08:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.333 uVs 14:08:51 Integrated Voltage Measurement... 14:09:00 Voltage Offset Correction: v_off_ini = -23.762 uV, v_off_fin = -18.442 uV 14:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.686 uVs 14:09:00 Integrated Voltage Measurement... 14:09:09 Voltage Offset Correction: v_off_ini = -33.740 uV, v_off_fin = -21.885 uV 14:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.973 uVs 14:09:09 Integrated Voltage Measurement... 14:09:18 Voltage Offset Correction: v_off_ini = -23.331 uV, v_off_fin = -31.609 uV 14:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.641 uVs 14:09:18 Integrated Voltage Measurement... 14:09:27 Voltage Offset Correction: v_off_ini = -25.487 uV, v_off_fin = -31.833 uV 14:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.214 uVs 14:09:31 I1X Average and RMS of Measurements VT = -144.263 +- 4.095 uVs I1X = 28.853 +- 0.819 uTm 14:09:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:09:38 Integrated Voltage Measurement... 14:09:47 Voltage Offset Correction: v_off_ini = -28.626 uV, v_off_fin = -36.367 uV 14:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.879 uVs 14:09:47 Integrated Voltage Measurement... 14:09:56 Voltage Offset Correction: v_off_ini = -27.011 uV, v_off_fin = -24.998 uV 14:09:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.932 uVs 14:09:56 Integrated Voltage Measurement... 14:10:05 Voltage Offset Correction: v_off_ini = -35.924 uV, v_off_fin = -41.991 uV 14:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.099 uVs 14:10:05 Integrated Voltage Measurement... 14:10:14 Voltage Offset Correction: v_off_ini = -32.832 uV, v_off_fin = -17.386 uV 14:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.169 uVs 14:10:14 Integrated Voltage Measurement... 14:10:23 Voltage Offset Correction: v_off_ini = -29.443 uV, v_off_fin = -30.275 uV 14:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.490 uVs 14:10:23 Integrated Voltage Measurement... 14:10:32 Voltage Offset Correction: v_off_ini = -16.381 uV, v_off_fin = -17.857 uV 14:10:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.410 uVs 14:10:36 I1Y Average and RMS of Measurements VT = -266.330 +- 1.010 uVs I1Y = -53.266 +- 0.202 uTm 14:10:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:10:41 Integrated Voltage Measurement... 14:10:50 Voltage Offset Correction: v_off_ini = -50.783 uV, v_off_fin = -48.184 uV 14:10:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.437 uVs 14:10:50 Integrated Voltage Measurement... 14:10:59 Voltage Offset Correction: v_off_ini = -41.926 uV, v_off_fin = -36.899 uV 14:10:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.695 uVs 14:10:59 Integrated Voltage Measurement... 14:11:08 Voltage Offset Correction: v_off_ini = -42.844 uV, v_off_fin = -43.580 uV 14:11:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.114 uVs 14:11:08 Integrated Voltage Measurement... 14:11:17 Voltage Offset Correction: v_off_ini = -33.037 uV, v_off_fin = -26.396 uV 14:11:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.715 uVs 14:11:17 Integrated Voltage Measurement... 14:11:26 Voltage Offset Correction: v_off_ini = -46.117 uV, v_off_fin = -49.078 uV 14:11:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.895 uVs 14:11:26 Integrated Voltage Measurement... 14:11:35 Voltage Offset Correction: v_off_ini = -28.321 uV, v_off_fin = -33.830 uV 14:11:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.881 uVs 14:11:38 I2X Average and RMS of Measurements VT = -123.789 +- 8.790 uVs I2X = 11.389 +- 0.809 uTm^2 14:11:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:11:43 Integrated Voltage Measurement... 14:11:52 Voltage Offset Correction: v_off_ini = -25.201 uV, v_off_fin = -33.274 uV 14:11:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.579 uVs 14:11:52 Integrated Voltage Measurement... 14:12:01 Voltage Offset Correction: v_off_ini = -39.807 uV, v_off_fin = -30.141 uV 14:12:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.109 uVs 14:12:01 Integrated Voltage Measurement... 14:12:10 Voltage Offset Correction: v_off_ini = -26.125 uV, v_off_fin = -28.691 uV 14:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.023 uVs 14:12:10 Integrated Voltage Measurement... 14:12:19 Voltage Offset Correction: v_off_ini = -31.261 uV, v_off_fin = -48.239 uV 14:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.600 uVs 14:12:19 Integrated Voltage Measurement... 14:12:28 Voltage Offset Correction: v_off_ini = -48.609 uV, v_off_fin = -40.210 uV 14:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.149 uVs 14:12:28 Integrated Voltage Measurement... 14:12:37 Voltage Offset Correction: v_off_ini = -32.370 uV, v_off_fin = -44.290 uV 14:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.826 uVs 14:12:40 I2Y Average and RMS of Measurements VT = -299.714 +- 8.594 uVs I2Y = -27.574 +- 0.791 uTm^2 14:12:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:12:48 Integrated Voltage Measurement... 14:12:57 Voltage Offset Correction: v_off_ini = -38.068 uV, v_off_fin = -48.860 uV 14:12:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.451 uVs 14:12:57 Integrated Voltage Measurement... 14:13:06 Voltage Offset Correction: v_off_ini = -46.770 uV, v_off_fin = -58.898 uV 14:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.750 uVs 14:13:06 Integrated Voltage Measurement... 14:13:15 Voltage Offset Correction: v_off_ini = -52.210 uV, v_off_fin = -53.657 uV 14:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.802 uVs 14:13:15 Integrated Voltage Measurement... 14:13:24 Voltage Offset Correction: v_off_ini = -45.121 uV, v_off_fin = -42.911 uV 14:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.723 uVs 14:13:24 Integrated Voltage Measurement... 14:13:33 Voltage Offset Correction: v_off_ini = -56.550 uV, v_off_fin = -61.835 uV 14:13:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.632 uVs 14:13:33 Integrated Voltage Measurement... 14:13:42 Voltage Offset Correction: v_off_ini = -54.080 uV, v_off_fin = -60.855 uV 14:13:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 138.400 uVs 14:13:46 I1X Average and RMS of Measurements VT = -129.960 +- 6.179 uVs I1X = 25.993 +- 1.235 uTm 14:13:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:13:53 Integrated Voltage Measurement... 14:14:02 Voltage Offset Correction: v_off_ini = -47.191 uV, v_off_fin = -65.952 uV 14:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.905 uVs 14:14:02 Integrated Voltage Measurement... 14:14:11 Voltage Offset Correction: v_off_ini = -64.388 uV, v_off_fin = -39.786 uV 14:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.298 uVs 14:14:11 Integrated Voltage Measurement... 14:14:20 Voltage Offset Correction: v_off_ini = -52.961 uV, v_off_fin = -71.471 uV 14:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.123 uVs 14:14:20 Integrated Voltage Measurement... 14:14:29 Voltage Offset Correction: v_off_ini = -45.130 uV, v_off_fin = -47.712 uV 14:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.314 uVs 14:14:29 Integrated Voltage Measurement... 14:14:38 Voltage Offset Correction: v_off_ini = -60.854 uV, v_off_fin = -61.296 uV 14:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.016 uVs 14:14:38 Integrated Voltage Measurement... 14:14:47 Voltage Offset Correction: v_off_ini = -56.577 uV, v_off_fin = -40.810 uV 14:14:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.324 uVs 14:14:51 I1Y Average and RMS of Measurements VT = -256.997 +- 5.123 uVs I1Y = -51.399 +- 1.025 uTm 14:14:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:14:56 Integrated Voltage Measurement... 14:15:05 Voltage Offset Correction: v_off_ini = -47.695 uV, v_off_fin = -64.592 uV 14:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.434 uVs 14:15:05 Integrated Voltage Measurement... 14:15:14 Voltage Offset Correction: v_off_ini = -45.834 uV, v_off_fin = -53.089 uV 14:15:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.195 uVs 14:15:14 Integrated Voltage Measurement... 14:15:23 Voltage Offset Correction: v_off_ini = -69.278 uV, v_off_fin = -96.544 uV 14:15:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.287 uVs 14:15:24 Integrated Voltage Measurement... 14:15:32 Voltage Offset Correction: v_off_ini = -69.909 uV, v_off_fin = -74.912 uV 14:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.412 uVs 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = -70.972 uV, v_off_fin = -76.408 uV 14:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.593 uVs 14:15:42 Integrated Voltage Measurement... 14:15:51 Voltage Offset Correction: v_off_ini = -82.167 uV, v_off_fin = -74.006 uV 14:15:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.434 uVs 14:15:53 I2X Average and RMS of Measurements VT = -124.726 +- 9.370 uVs I2X = 11.475 +- 0.862 uTm^2 14:15:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:15:58 Integrated Voltage Measurement... 14:16:07 Voltage Offset Correction: v_off_ini = -68.421 uV, v_off_fin = -72.175 uV 14:16:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.156 uVs 14:16:07 Integrated Voltage Measurement... 14:16:16 Voltage Offset Correction: v_off_ini = -75.813 uV, v_off_fin = -53.821 uV 14:16:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.401 uVs 14:16:16 Integrated Voltage Measurement... 14:16:25 Voltage Offset Correction: v_off_ini = -72.934 uV, v_off_fin = -77.270 uV 14:16:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.428 uVs 14:16:25 Integrated Voltage Measurement... 14:16:34 Voltage Offset Correction: v_off_ini = -70.415 uV, v_off_fin = -68.554 uV 14:16:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.886 uVs 14:16:34 Integrated Voltage Measurement... 14:16:43 Voltage Offset Correction: v_off_ini = -78.029 uV, v_off_fin = -69.366 uV 14:16:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.186 uVs 14:16:43 Integrated Voltage Measurement... 14:16:52 Voltage Offset Correction: v_off_ini = -70.549 uV, v_off_fin = -63.745 uV 14:16:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.073 uVs 14:16:55 I2Y Average and RMS of Measurements VT = -307.355 +- 0.903 uVs I2Y = -28.277 +- 0.083 uTm^2 14:16:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:03 Integrated Voltage Measurement... 14:17:12 Voltage Offset Correction: v_off_ini = -53.866 uV, v_off_fin = -55.289 uV 14:17:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -122.237 uVs 14:17:12 Integrated Voltage Measurement... 14:17:21 Voltage Offset Correction: v_off_ini = -39.839 uV, v_off_fin = -39.630 uV 14:17:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.487 uVs 14:17:21 Integrated Voltage Measurement... 14:17:30 Voltage Offset Correction: v_off_ini = -44.062 uV, v_off_fin = -43.787 uV 14:17:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.050 uVs 14:17:30 Integrated Voltage Measurement... 14:17:39 Voltage Offset Correction: v_off_ini = -20.208 uV, v_off_fin = -32.152 uV 14:17:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.692 uVs 14:17:39 Integrated Voltage Measurement... 14:17:48 Voltage Offset Correction: v_off_ini = -36.422 uV, v_off_fin = -45.696 uV 14:17:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.559 uVs 14:17:48 Integrated Voltage Measurement... 14:17:57 Voltage Offset Correction: v_off_ini = -31.119 uV, v_off_fin = -32.484 uV 14:17:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.583 uVs 14:18:01 I1X Average and RMS of Measurements VT = -128.601 +- 4.092 uVs I1X = 25.721 +- 0.819 uTm 14:18:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:08 Integrated Voltage Measurement... 14:18:17 Voltage Offset Correction: v_off_ini = -53.978 uV, v_off_fin = -57.130 uV 14:18:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.170 uVs 14:18:17 Integrated Voltage Measurement... 14:18:26 Voltage Offset Correction: v_off_ini = -31.801 uV, v_off_fin = -26.603 uV 14:18:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.968 uVs 14:18:26 Integrated Voltage Measurement... 14:18:35 Voltage Offset Correction: v_off_ini = -59.740 uV, v_off_fin = -62.531 uV 14:18:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.131 uVs 14:18:35 Integrated Voltage Measurement... 14:18:44 Voltage Offset Correction: v_off_ini = -68.109 uV, v_off_fin = -47.416 uV 14:18:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.343 uVs 14:18:44 Integrated Voltage Measurement... 14:18:53 Voltage Offset Correction: v_off_ini = -71.331 uV, v_off_fin = -73.775 uV 14:18:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.653 uVs 14:18:53 Integrated Voltage Measurement... 14:19:02 Voltage Offset Correction: v_off_ini = -70.908 uV, v_off_fin = -65.493 uV 14:19:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.581 uVs 14:19:06 I1Y Average and RMS of Measurements VT = -254.141 +- 4.587 uVs I1Y = -50.830 +- 0.917 uTm 14:19:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:12 Integrated Voltage Measurement... 14:19:21 Voltage Offset Correction: v_off_ini = -66.567 uV, v_off_fin = -75.601 uV 14:19:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -128.932 uVs 14:19:21 Integrated Voltage Measurement... 14:19:30 Voltage Offset Correction: v_off_ini = -60.834 uV, v_off_fin = -40.663 uV 14:19:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.160 uVs 14:19:30 Integrated Voltage Measurement... 14:19:39 Voltage Offset Correction: v_off_ini = -70.105 uV, v_off_fin = -84.551 uV 14:19:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.387 uVs 14:19:39 Integrated Voltage Measurement... 14:19:48 Voltage Offset Correction: v_off_ini = -84.207 uV, v_off_fin = -76.280 uV 14:19:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.587 uVs 14:19:48 Integrated Voltage Measurement... 14:19:57 Voltage Offset Correction: v_off_ini = -89.724 uV, v_off_fin = -83.480 uV 14:19:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.535 uVs 14:19:57 Integrated Voltage Measurement... 14:20:06 Voltage Offset Correction: v_off_ini = -80.859 uV, v_off_fin = -73.382 uV 14:20:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.627 uVs 14:20:08 I2X Average and RMS of Measurements VT = -117.038 +- 4.300 uVs I2X = 10.768 +- 0.396 uTm^2 14:20:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:13 Integrated Voltage Measurement... 14:20:22 Voltage Offset Correction: v_off_ini = -69.477 uV, v_off_fin = -75.452 uV 14:20:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.244 uVs 14:20:22 Integrated Voltage Measurement... 14:20:31 Voltage Offset Correction: v_off_ini = -71.988 uV, v_off_fin = -72.933 uV 14:20:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.561 uVs 14:20:31 Integrated Voltage Measurement... 14:20:40 Voltage Offset Correction: v_off_ini = -64.383 uV, v_off_fin = -83.581 uV 14:20:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.818 uVs 14:20:40 Integrated Voltage Measurement... 14:20:49 Voltage Offset Correction: v_off_ini = -86.693 uV, v_off_fin = -81.599 uV 14:20:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.652 uVs 14:20:49 Integrated Voltage Measurement... 14:20:58 Voltage Offset Correction: v_off_ini = -80.700 uV, v_off_fin = -90.712 uV 14:20:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.929 uVs 14:20:59 Integrated Voltage Measurement... 14:21:08 Voltage Offset Correction: v_off_ini = -90.878 uV, v_off_fin = -84.848 uV 14:21:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.943 uVs 14:21:10 I2Y Average and RMS of Measurements VT = -310.691 +- 3.391 uVs I2Y = -28.584 +- 0.312 uTm^2 14:21:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:21:18 Integrated Voltage Measurement... 14:21:27 Voltage Offset Correction: v_off_ini = -84.491 uV, v_off_fin = -88.517 uV 14:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -131.146 uVs 14:21:27 Integrated Voltage Measurement... 14:21:36 Voltage Offset Correction: v_off_ini = -96.693 uV, v_off_fin = -94.397 uV 14:21:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.244 uVs 14:21:36 Integrated Voltage Measurement... 14:21:45 Voltage Offset Correction: v_off_ini = -95.611 uV, v_off_fin = -96.213 uV 14:21:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.017 uVs 14:21:45 Integrated Voltage Measurement... 14:21:54 Voltage Offset Correction: v_off_ini = -92.005 uV, v_off_fin = -86.677 uV 14:21:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 88.697 uVs 14:21:54 Integrated Voltage Measurement... 14:22:03 Voltage Offset Correction: v_off_ini = -68.624 uV, v_off_fin = -75.261 uV 14:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -126.697 uVs 14:22:03 Integrated Voltage Measurement... 14:22:12 Voltage Offset Correction: v_off_ini = -87.159 uV, v_off_fin = -88.029 uV 14:22:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.742 uVs 14:22:17 I1X Average and RMS of Measurements VT = -112.757 +- 9.442 uVs I1X = 22.553 +- 1.888 uTm 14:22:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:22:23 Integrated Voltage Measurement... 14:22:32 Voltage Offset Correction: v_off_ini = -98.937 uV, v_off_fin = -123.140 uV 14:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.661 uVs 14:22:32 Integrated Voltage Measurement... 14:22:41 Voltage Offset Correction: v_off_ini = -110.313 uV, v_off_fin = -89.385 uV 14:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.348 uVs 14:22:41 Integrated Voltage Measurement... 14:22:50 Voltage Offset Correction: v_off_ini = -101.646 uV, v_off_fin = -111.950 uV 14:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.284 uVs 14:22:50 Integrated Voltage Measurement... 14:22:59 Voltage Offset Correction: v_off_ini = -109.048 uV, v_off_fin = -100.244 uV 14:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.193 uVs 14:22:59 Integrated Voltage Measurement... 14:23:08 Voltage Offset Correction: v_off_ini = -91.789 uV, v_off_fin = -118.458 uV 14:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.428 uVs 14:23:08 Integrated Voltage Measurement... 14:23:17 Voltage Offset Correction: v_off_ini = -107.934 uV, v_off_fin = -91.296 uV 14:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.622 uVs 14:23:22 I1Y Average and RMS of Measurements VT = -259.256 +- 5.962 uVs I1Y = -51.851 +- 1.192 uTm 14:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:23:27 Integrated Voltage Measurement... 14:23:36 Voltage Offset Correction: v_off_ini = -99.181 uV, v_off_fin = -104.301 uV 14:23:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.264 uVs 14:23:36 Integrated Voltage Measurement... 14:23:45 Voltage Offset Correction: v_off_ini = -96.781 uV, v_off_fin = -88.707 uV 14:23:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.376 uVs 14:23:45 Integrated Voltage Measurement... 14:23:54 Voltage Offset Correction: v_off_ini = -97.741 uV, v_off_fin = -99.652 uV 14:23:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.591 uVs 14:23:54 Integrated Voltage Measurement... 14:24:03 Voltage Offset Correction: v_off_ini = -79.261 uV, v_off_fin = -68.883 uV 14:24:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.169 uVs 14:24:03 Integrated Voltage Measurement... 14:24:12 Voltage Offset Correction: v_off_ini = -93.348 uV, v_off_fin = -103.952 uV 14:24:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.831 uVs 14:24:12 Integrated Voltage Measurement... 14:24:21 Voltage Offset Correction: v_off_ini = -101.076 uV, v_off_fin = -84.270 uV 14:24:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.280 uVs 14:24:23 I2X Average and RMS of Measurements VT = -105.085 +- 3.813 uVs I2X = 9.668 +- 0.350 uTm^2 14:24:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:24:29 Integrated Voltage Measurement... 14:24:38 Voltage Offset Correction: v_off_ini = -90.429 uV, v_off_fin = -91.374 uV 14:24:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.172 uVs 14:24:38 Integrated Voltage Measurement... 14:24:47 Voltage Offset Correction: v_off_ini = -101.832 uV, v_off_fin = -101.756 uV 14:24:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.668 uVs 14:24:47 Integrated Voltage Measurement... 14:24:56 Voltage Offset Correction: v_off_ini = -99.911 uV, v_off_fin = -100.451 uV 14:24:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.261 uVs 14:24:56 Integrated Voltage Measurement... 14:25:05 Voltage Offset Correction: v_off_ini = -105.708 uV, v_off_fin = -101.880 uV 14:25:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 301.393 uVs 14:25:05 Integrated Voltage Measurement... 14:25:14 Voltage Offset Correction: v_off_ini = -102.136 uV, v_off_fin = -103.291 uV 14:25:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.863 uVs 14:25:14 Integrated Voltage Measurement... 14:25:23 Voltage Offset Correction: v_off_ini = -104.386 uV, v_off_fin = -102.579 uV 14:25:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.591 uVs 14:25:25 I2Y Average and RMS of Measurements VT = -303.825 +- 4.492 uVs I2Y = -27.952 +- 0.413 uTm^2 14:25:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:25:33 Integrated Voltage Measurement... 14:25:42 Voltage Offset Correction: v_off_ini = -109.991 uV, v_off_fin = -113.880 uV 14:25:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.741 uVs 14:25:42 Integrated Voltage Measurement... 14:25:51 Voltage Offset Correction: v_off_ini = -114.856 uV, v_off_fin = -118.677 uV 14:25:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.663 uVs 14:25:52 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = -110.155 uV, v_off_fin = -115.820 uV 14:26:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.514 uVs 14:26:01 Integrated Voltage Measurement... 14:26:09 Voltage Offset Correction: v_off_ini = -109.460 uV, v_off_fin = -111.165 uV 14:26:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.549 uVs 14:26:10 Integrated Voltage Measurement... 14:26:19 Voltage Offset Correction: v_off_ini = -114.043 uV, v_off_fin = -130.248 uV 14:26:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.806 uVs 14:26:19 Integrated Voltage Measurement... 14:26:28 Voltage Offset Correction: v_off_ini = -132.301 uV, v_off_fin = -114.970 uV 14:26:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.439 uVs 14:26:32 I1X Average and RMS of Measurements VT = -95.952 +- 5.071 uVs I1X = 19.190 +- 1.014 uTm 14:26:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:26:39 Integrated Voltage Measurement... 14:26:48 Voltage Offset Correction: v_off_ini = -97.907 uV, v_off_fin = -115.007 uV 14:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.679 uVs 14:26:48 Integrated Voltage Measurement... 14:26:57 Voltage Offset Correction: v_off_ini = -106.077 uV, v_off_fin = -95.200 uV 14:26:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.868 uVs 14:26:57 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = -99.715 uV, v_off_fin = -107.155 uV 14:27:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.995 uVs 14:27:06 Integrated Voltage Measurement... 14:27:15 Voltage Offset Correction: v_off_ini = -92.545 uV, v_off_fin = -86.146 uV 14:27:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.162 uVs 14:27:15 Integrated Voltage Measurement... 14:27:24 Voltage Offset Correction: v_off_ini = -90.146 uV, v_off_fin = -103.752 uV 14:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.255 uVs 14:27:24 Integrated Voltage Measurement... 14:27:33 Voltage Offset Correction: v_off_ini = -98.496 uV, v_off_fin = -93.233 uV 14:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.103 uVs 14:27:37 I1Y Average and RMS of Measurements VT = -257.010 +- 0.247 uVs I1Y = -51.402 +- 0.049 uTm 14:27:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:27:42 Integrated Voltage Measurement... 14:27:51 Voltage Offset Correction: v_off_ini = -102.080 uV, v_off_fin = -101.462 uV 14:27:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.396 uVs 14:27:51 Integrated Voltage Measurement... 14:28:00 Voltage Offset Correction: v_off_ini = -106.294 uV, v_off_fin = -90.691 uV 14:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.930 uVs 14:28:00 Integrated Voltage Measurement... 14:28:09 Voltage Offset Correction: v_off_ini = -103.413 uV, v_off_fin = -107.429 uV 14:28:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.880 uVs 14:28:09 Integrated Voltage Measurement... 14:28:18 Voltage Offset Correction: v_off_ini = -105.918 uV, v_off_fin = -94.503 uV 14:28:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.580 uVs 14:28:18 Integrated Voltage Measurement... 14:28:27 Voltage Offset Correction: v_off_ini = -98.770 uV, v_off_fin = -94.648 uV 14:28:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.623 uVs 14:28:27 Integrated Voltage Measurement... 14:28:36 Voltage Offset Correction: v_off_ini = -99.789 uV, v_off_fin = -92.893 uV 14:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.226 uVs 14:28:39 I2X Average and RMS of Measurements VT = -86.439 +- 5.893 uVs I2X = 7.952 +- 0.542 uTm^2 14:28:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:28:44 Integrated Voltage Measurement... 14:28:53 Voltage Offset Correction: v_off_ini = -98.029 uV, v_off_fin = -110.297 uV 14:28:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.878 uVs 14:28:53 Integrated Voltage Measurement... 14:29:02 Voltage Offset Correction: v_off_ini = -105.086 uV, v_off_fin = -100.882 uV 14:29:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.262 uVs 14:29:02 Integrated Voltage Measurement... 14:29:11 Voltage Offset Correction: v_off_ini = -85.271 uV, v_off_fin = -96.406 uV 14:29:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.422 uVs 14:29:11 Integrated Voltage Measurement... 14:29:20 Voltage Offset Correction: v_off_ini = -94.200 uV, v_off_fin = -89.145 uV 14:29:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.036 uVs 14:29:20 Integrated Voltage Measurement... 14:29:29 Voltage Offset Correction: v_off_ini = -97.564 uV, v_off_fin = -99.398 uV 14:29:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.885 uVs 14:29:29 Integrated Voltage Measurement... 14:29:38 Voltage Offset Correction: v_off_ini = -98.398 uV, v_off_fin = -98.932 uV 14:29:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.707 uVs 14:29:40 I2Y Average and RMS of Measurements VT = -309.531 +- 6.366 uVs I2Y = -28.477 +- 0.586 uTm^2 14:29:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:30:02 Integrated Voltage Measurement... 14:30:11 Voltage Offset Correction: v_off_ini = -101.993 uV, v_off_fin = -111.270 uV 14:30:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.451 uVs 14:30:11 Integrated Voltage Measurement... 14:30:20 Voltage Offset Correction: v_off_ini = -106.374 uV, v_off_fin = -98.719 uV 14:30:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.469 uVs 14:30:20 Integrated Voltage Measurement... 14:30:29 Voltage Offset Correction: v_off_ini = -106.761 uV, v_off_fin = -99.711 uV 14:30:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.128 uVs 14:30:29 Integrated Voltage Measurement... 14:30:38 Voltage Offset Correction: v_off_ini = -90.081 uV, v_off_fin = -87.018 uV 14:30:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.546 uVs 14:30:38 Integrated Voltage Measurement... 14:30:47 Voltage Offset Correction: v_off_ini = -108.118 uV, v_off_fin = -94.737 uV 14:30:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.584 uVs 14:30:47 Integrated Voltage Measurement... 14:30:56 Voltage Offset Correction: v_off_ini = -89.716 uV, v_off_fin = -92.100 uV 14:30:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.921 uVs 14:31:00 I1X Average and RMS of Measurements VT = -137.350 +- 5.010 uVs I1X = 27.470 +- 1.002 uTm 14:31:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:31:07 Integrated Voltage Measurement... 14:31:16 Voltage Offset Correction: v_off_ini = -98.261 uV, v_off_fin = -103.513 uV 14:31:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.183 uVs 14:31:16 Integrated Voltage Measurement... 14:31:25 Voltage Offset Correction: v_off_ini = -94.311 uV, v_off_fin = -89.135 uV 14:31:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.321 uVs 14:31:25 Integrated Voltage Measurement... 14:31:34 Voltage Offset Correction: v_off_ini = -92.638 uV, v_off_fin = -110.402 uV 14:31:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.440 uVs 14:31:34 Integrated Voltage Measurement... 14:31:43 Voltage Offset Correction: v_off_ini = -92.374 uV, v_off_fin = -83.306 uV 14:31:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.449 uVs 14:31:43 Integrated Voltage Measurement... 14:31:52 Voltage Offset Correction: v_off_ini = -80.630 uV, v_off_fin = -96.332 uV 14:31:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.997 uVs 14:31:52 Integrated Voltage Measurement... 14:32:01 Voltage Offset Correction: v_off_ini = -107.605 uV, v_off_fin = -91.105 uV 14:32:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.105 uVs 14:32:05 I1Y Average and RMS of Measurements VT = -228.749 +- 4.200 uVs I1Y = -45.750 +- 0.840 uTm 14:32:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:32:13 Integrated Voltage Measurement... 14:32:22 Voltage Offset Correction: v_off_ini = -100.997 uV, v_off_fin = -105.800 uV 14:32:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.874 uVs 14:32:22 Integrated Voltage Measurement... 14:32:31 Voltage Offset Correction: v_off_ini = -105.209 uV, v_off_fin = -97.263 uV 14:32:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.457 uVs 14:32:31 Integrated Voltage Measurement... 14:32:40 Voltage Offset Correction: v_off_ini = -107.150 uV, v_off_fin = -107.301 uV 14:32:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.163 uVs 14:32:40 Integrated Voltage Measurement... 14:32:49 Voltage Offset Correction: v_off_ini = -103.727 uV, v_off_fin = -97.954 uV 14:32:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.372 uVs 14:32:49 Integrated Voltage Measurement... 14:32:58 Voltage Offset Correction: v_off_ini = -94.106 uV, v_off_fin = -108.301 uV 14:32:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -150.332 uVs 14:32:58 Integrated Voltage Measurement... 14:33:07 Voltage Offset Correction: v_off_ini = -93.991 uV, v_off_fin = -96.349 uV 14:33:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.867 uVs 14:33:09 I2X Average and RMS of Measurements VT = -127.844 +- 13.074 uVs I2X = 11.762 +- 1.203 uTm^2 14:33:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:33:17 Integrated Voltage Measurement... 14:33:26 Voltage Offset Correction: v_off_ini = -114.145 uV, v_off_fin = -107.953 uV 14:33:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.769 uVs 14:33:26 Integrated Voltage Measurement... 14:33:35 Voltage Offset Correction: v_off_ini = -95.727 uV, v_off_fin = -93.521 uV 14:33:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.146 uVs 14:33:35 Integrated Voltage Measurement... 14:33:44 Voltage Offset Correction: v_off_ini = -103.820 uV, v_off_fin = -119.049 uV 14:33:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.045 uVs 14:33:44 Integrated Voltage Measurement... 14:33:53 Voltage Offset Correction: v_off_ini = -118.038 uV, v_off_fin = -115.294 uV 14:33:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.466 uVs 14:33:53 Integrated Voltage Measurement... 14:34:02 Voltage Offset Correction: v_off_ini = -123.278 uV, v_off_fin = -126.533 uV 14:34:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.768 uVs 14:34:02 Integrated Voltage Measurement... 14:34:11 Voltage Offset Correction: v_off_ini = -122.338 uV, v_off_fin = -120.008 uV 14:34:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.215 uVs 14:34:14 I2Y Average and RMS of Measurements VT = -256.068 +- 9.681 uVs I2Y = -23.558 +- 0.891 uTm^2 14:34:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:34:23 Integrated Voltage Measurement... 14:34:32 Voltage Offset Correction: v_off_ini = -99.707 uV, v_off_fin = -106.686 uV 14:34:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.454 uVs 14:34:32 Integrated Voltage Measurement... 14:34:41 Voltage Offset Correction: v_off_ini = -99.338 uV, v_off_fin = -95.360 uV 14:34:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.158 uVs 14:34:41 Integrated Voltage Measurement... 14:34:50 Voltage Offset Correction: v_off_ini = -113.660 uV, v_off_fin = -126.819 uV 14:34:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.895 uVs 14:34:50 Integrated Voltage Measurement... 14:34:59 Voltage Offset Correction: v_off_ini = -125.391 uV, v_off_fin = -112.660 uV 14:34:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.866 uVs 14:34:59 Integrated Voltage Measurement... 14:35:08 Voltage Offset Correction: v_off_ini = -111.171 uV, v_off_fin = -111.825 uV 14:35:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.527 uVs 14:35:08 Integrated Voltage Measurement... 14:35:17 Voltage Offset Correction: v_off_ini = -105.256 uV, v_off_fin = -108.662 uV 14:35:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.220 uVs 14:35:21 I1X Average and RMS of Measurements VT = -137.520 +- 14.574 uVs I1X = 27.504 +- 2.914 uTm 14:35:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:35:28 Integrated Voltage Measurement... 14:35:37 Voltage Offset Correction: v_off_ini = -111.103 uV, v_off_fin = -130.376 uV 14:35:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.115 uVs 14:35:37 Integrated Voltage Measurement... 14:35:46 Voltage Offset Correction: v_off_ini = -125.456 uV, v_off_fin = -110.120 uV 14:35:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.997 uVs 14:35:46 Integrated Voltage Measurement... 14:35:55 Voltage Offset Correction: v_off_ini = -122.836 uV, v_off_fin = -125.271 uV 14:35:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.135 uVs 14:35:55 Integrated Voltage Measurement... 14:36:04 Voltage Offset Correction: v_off_ini = -115.436 uV, v_off_fin = -112.287 uV 14:36:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.251 uVs 14:36:04 Integrated Voltage Measurement... 14:36:13 Voltage Offset Correction: v_off_ini = -132.400 uV, v_off_fin = -122.156 uV 14:36:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.148 uVs 14:36:13 Integrated Voltage Measurement... 14:36:22 Voltage Offset Correction: v_off_ini = -106.932 uV, v_off_fin = -103.746 uV 14:36:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.710 uVs 14:36:26 I1Y Average and RMS of Measurements VT = -248.559 +- 7.216 uVs I1Y = -49.712 +- 1.443 uTm 14:36:31 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:36:34 Integrated Voltage Measurement... 14:36:43 Voltage Offset Correction: v_off_ini = -110.920 uV, v_off_fin = -113.697 uV 14:36:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.578 uVs 14:36:43 Integrated Voltage Measurement... 14:36:52 Voltage Offset Correction: v_off_ini = -123.113 uV, v_off_fin = -95.723 uV 14:36:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.708 uVs 14:36:52 Integrated Voltage Measurement... 14:37:01 Voltage Offset Correction: v_off_ini = -114.563 uV, v_off_fin = -121.564 uV 14:37:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.857 uVs 14:37:01 Integrated Voltage Measurement... 14:37:10 Voltage Offset Correction: v_off_ini = -106.252 uV, v_off_fin = -104.953 uV 14:37:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.290 uVs 14:37:10 Integrated Voltage Measurement... 14:37:19 Voltage Offset Correction: v_off_ini = -123.002 uV, v_off_fin = -133.785 uV 14:37:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.452 uVs 14:37:19 Integrated Voltage Measurement... 14:37:28 Voltage Offset Correction: v_off_ini = -134.347 uV, v_off_fin = -113.297 uV 14:37:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 132.522 uVs 14:37:30 I2X Average and RMS of Measurements VT = -130.068 +- 7.654 uVs I2X = 11.966 +- 0.704 uTm^2 14:37:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:37:38 Integrated Voltage Measurement... 14:37:47 Voltage Offset Correction: v_off_ini = -141.794 uV, v_off_fin = -139.161 uV 14:37:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.602 uVs 14:37:47 Integrated Voltage Measurement... 14:37:56 Voltage Offset Correction: v_off_ini = -145.631 uV, v_off_fin = -134.328 uV 14:37:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.464 uVs 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = -136.442 uV, v_off_fin = -138.017 uV 14:38:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.458 uVs 14:38:05 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = -131.339 uV, v_off_fin = -134.426 uV 14:38:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.163 uVs 14:38:14 Integrated Voltage Measurement... 14:38:23 Voltage Offset Correction: v_off_ini = -129.770 uV, v_off_fin = -142.516 uV 14:38:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.567 uVs 14:38:23 Integrated Voltage Measurement... 14:38:32 Voltage Offset Correction: v_off_ini = -149.551 uV, v_off_fin = -146.558 uV 14:38:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.791 uVs 14:38:35 I2Y Average and RMS of Measurements VT = -283.341 +- 3.620 uVs I2Y = -26.067 +- 0.333 uTm^2 14:38:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:44 Integrated Voltage Measurement... 14:38:53 Voltage Offset Correction: v_off_ini = -152.201 uV, v_off_fin = -152.743 uV 14:38:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.977 uVs 14:38:53 Integrated Voltage Measurement... 14:39:02 Voltage Offset Correction: v_off_ini = -140.263 uV, v_off_fin = -135.031 uV 14:39:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.107 uVs 14:39:02 Integrated Voltage Measurement... 14:39:11 Voltage Offset Correction: v_off_ini = -141.441 uV, v_off_fin = -150.219 uV 14:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.850 uVs 14:39:11 Integrated Voltage Measurement... 14:39:20 Voltage Offset Correction: v_off_ini = -125.959 uV, v_off_fin = -137.425 uV 14:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.792 uVs 14:39:20 Integrated Voltage Measurement... 14:39:29 Voltage Offset Correction: v_off_ini = -148.754 uV, v_off_fin = -142.881 uV 14:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.247 uVs 14:39:29 Integrated Voltage Measurement... 14:39:38 Voltage Offset Correction: v_off_ini = -141.504 uV, v_off_fin = -136.656 uV 14:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.552 uVs 14:39:42 I1X Average and RMS of Measurements VT = -137.088 +- 5.437 uVs I1X = 27.418 +- 1.087 uTm 14:39:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:49 Integrated Voltage Measurement... 14:39:58 Voltage Offset Correction: v_off_ini = -130.751 uV, v_off_fin = -131.293 uV 14:39:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.680 uVs 14:39:58 Integrated Voltage Measurement... 14:40:07 Voltage Offset Correction: v_off_ini = -110.543 uV, v_off_fin = -102.839 uV 14:40:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.932 uVs 14:40:07 Integrated Voltage Measurement... 14:40:16 Voltage Offset Correction: v_off_ini = -115.337 uV, v_off_fin = -127.150 uV 14:40:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.458 uVs 14:40:16 Integrated Voltage Measurement... 14:40:25 Voltage Offset Correction: v_off_ini = -124.927 uV, v_off_fin = -116.053 uV 14:40:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.034 uVs 14:40:25 Integrated Voltage Measurement... 14:40:34 Voltage Offset Correction: v_off_ini = -130.100 uV, v_off_fin = -134.273 uV 14:40:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.892 uVs 14:40:34 Integrated Voltage Measurement... 14:40:43 Voltage Offset Correction: v_off_ini = -131.895 uV, v_off_fin = -117.339 uV 14:40:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.964 uVs 14:40:47 I1Y Average and RMS of Measurements VT = -260.827 +- 4.241 uVs I1Y = -52.165 +- 0.848 uTm 14:40:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:55 Integrated Voltage Measurement... 14:41:04 Voltage Offset Correction: v_off_ini = -133.919 uV, v_off_fin = -128.430 uV 14:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.125 uVs 14:41:04 Integrated Voltage Measurement... 14:41:13 Voltage Offset Correction: v_off_ini = -128.714 uV, v_off_fin = -118.071 uV 14:41:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.577 uVs 14:41:13 Integrated Voltage Measurement... 14:41:22 Voltage Offset Correction: v_off_ini = -120.795 uV, v_off_fin = -136.140 uV 14:41:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.115 uVs 14:41:22 Integrated Voltage Measurement... 14:41:31 Voltage Offset Correction: v_off_ini = -128.564 uV, v_off_fin = -133.014 uV 14:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.727 uVs 14:41:31 Integrated Voltage Measurement... 14:41:40 Voltage Offset Correction: v_off_ini = -126.649 uV, v_off_fin = -132.691 uV 14:41:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.834 uVs 14:41:40 Integrated Voltage Measurement... 14:41:49 Voltage Offset Correction: v_off_ini = -144.201 uV, v_off_fin = -130.283 uV 14:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.336 uVs 14:41:51 I2X Average and RMS of Measurements VT = -129.785 +- 1.416 uVs I2X = 11.941 +- 0.130 uTm^2 14:41:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:59 Integrated Voltage Measurement... 14:42:08 Voltage Offset Correction: v_off_ini = -142.297 uV, v_off_fin = -142.972 uV 14:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.241 uVs 14:42:08 Integrated Voltage Measurement... 14:42:17 Voltage Offset Correction: v_off_ini = -148.179 uV, v_off_fin = -140.193 uV 14:42:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.608 uVs 14:42:17 Integrated Voltage Measurement... 14:42:26 Voltage Offset Correction: v_off_ini = -137.302 uV, v_off_fin = -142.961 uV 14:42:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.323 uVs 14:42:26 Integrated Voltage Measurement... 14:42:35 Voltage Offset Correction: v_off_ini = -142.193 uV, v_off_fin = -135.333 uV 14:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.876 uVs 14:42:35 Integrated Voltage Measurement... 14:42:44 Voltage Offset Correction: v_off_ini = -137.992 uV, v_off_fin = -142.664 uV 14:42:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.538 uVs 14:42:44 Integrated Voltage Measurement... 14:42:53 Voltage Offset Correction: v_off_ini = -125.420 uV, v_off_fin = -133.528 uV 14:42:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.759 uVs 14:42:56 I2Y Average and RMS of Measurements VT = -296.057 +- 10.676 uVs I2Y = -27.237 +- 0.982 uTm^2 14:43:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:43:05 Integrated Voltage Measurement... 14:43:14 Voltage Offset Correction: v_off_ini = -127.999 uV, v_off_fin = -146.549 uV 14:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -160.477 uVs 14:43:14 Integrated Voltage Measurement... 14:43:23 Voltage Offset Correction: v_off_ini = -152.176 uV, v_off_fin = -142.490 uV 14:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.147 uVs 14:43:23 Integrated Voltage Measurement... 14:43:32 Voltage Offset Correction: v_off_ini = -148.485 uV, v_off_fin = -154.933 uV 14:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.167 uVs 14:43:32 Integrated Voltage Measurement... 14:43:41 Voltage Offset Correction: v_off_ini = -155.836 uV, v_off_fin = -147.176 uV 14:43:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.533 uVs 14:43:41 Integrated Voltage Measurement... 14:43:50 Voltage Offset Correction: v_off_ini = -148.878 uV, v_off_fin = -154.303 uV 14:43:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.252 uVs 14:43:50 Integrated Voltage Measurement... 14:43:59 Voltage Offset Correction: v_off_ini = -146.993 uV, v_off_fin = -145.718 uV 14:43:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.151 uVs 14:44:03 I1X Average and RMS of Measurements VT = -150.455 +- 6.923 uVs I1X = 30.092 +- 1.385 uTm 14:44:05 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:44:10 Integrated Voltage Measurement... 14:44:19 Voltage Offset Correction: v_off_ini = -135.021 uV, v_off_fin = -148.319 uV 14:44:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -283.272 uVs 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = -138.458 uV, v_off_fin = -131.800 uV 14:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.301 uVs 14:44:28 Integrated Voltage Measurement... 14:44:37 Voltage Offset Correction: v_off_ini = -139.451 uV, v_off_fin = -158.314 uV 14:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.196 uVs 14:44:37 Integrated Voltage Measurement... 14:44:46 Voltage Offset Correction: v_off_ini = -131.057 uV, v_off_fin = -128.728 uV 14:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.311 uVs 14:44:46 Integrated Voltage Measurement... 14:44:55 Voltage Offset Correction: v_off_ini = -139.620 uV, v_off_fin = -169.475 uV 14:44:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -294.562 uVs 14:44:55 Integrated Voltage Measurement... 14:45:04 Voltage Offset Correction: v_off_ini = -170.167 uV, v_off_fin = -151.685 uV 14:45:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.099 uVs 14:45:08 I1Y Average and RMS of Measurements VT = -286.290 +- 8.278 uVs I1Y = -57.259 +- 1.654 uTm 14:45:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:45:16 Integrated Voltage Measurement... 14:45:25 Voltage Offset Correction: v_off_ini = -154.544 uV, v_off_fin = -166.151 uV 14:45:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.625 uVs 14:45:25 Integrated Voltage Measurement... 14:45:34 Voltage Offset Correction: v_off_ini = -158.962 uV, v_off_fin = -159.660 uV 14:45:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.104 uVs 14:45:34 Integrated Voltage Measurement... 14:45:43 Voltage Offset Correction: v_off_ini = -174.154 uV, v_off_fin = -160.961 uV 14:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.980 uVs 14:45:43 Integrated Voltage Measurement... 14:45:52 Voltage Offset Correction: v_off_ini = -159.110 uV, v_off_fin = -140.440 uV 14:45:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.426 uVs 14:45:52 Integrated Voltage Measurement... 14:46:01 Voltage Offset Correction: v_off_ini = -152.665 uV, v_off_fin = -161.334 uV 14:46:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.768 uVs 14:46:01 Integrated Voltage Measurement... 14:46:10 Voltage Offset Correction: v_off_ini = -145.353 uV, v_off_fin = -134.287 uV 14:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.504 uVs 14:46:12 I2X Average and RMS of Measurements VT = -134.568 +- 3.973 uVs I2X = 12.380 +- 0.366 uTm^2 14:46:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:46:20 Integrated Voltage Measurement... 14:46:29 Voltage Offset Correction: v_off_ini = -144.968 uV, v_off_fin = -139.737 uV 14:46:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.081 uVs 14:46:29 Integrated Voltage Measurement... 14:46:38 Voltage Offset Correction: v_off_ini = -134.550 uV, v_off_fin = -129.832 uV 14:46:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.629 uVs 14:46:38 Integrated Voltage Measurement... 14:46:47 Voltage Offset Correction: v_off_ini = -132.103 uV, v_off_fin = -132.948 uV 14:46:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.390 uVs 14:46:47 Integrated Voltage Measurement... 14:46:56 Voltage Offset Correction: v_off_ini = -137.518 uV, v_off_fin = -121.536 uV 14:46:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.635 uVs 14:46:56 Integrated Voltage Measurement... 14:47:05 Voltage Offset Correction: v_off_ini = -129.246 uV, v_off_fin = -122.784 uV 14:47:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.321 uVs 14:47:05 Integrated Voltage Measurement... 14:47:14 Voltage Offset Correction: v_off_ini = -120.396 uV, v_off_fin = -126.798 uV 14:47:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.888 uVs 14:47:17 I2Y Average and RMS of Measurements VT = -322.324 +- 3.517 uVs I2Y = -29.654 +- 0.324 uTm^2 14:47:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:47:26 Integrated Voltage Measurement... 14:47:35 Voltage Offset Correction: v_off_ini = -116.717 uV, v_off_fin = -119.166 uV 14:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -159.096 uVs 14:47:35 Integrated Voltage Measurement... 14:47:44 Voltage Offset Correction: v_off_ini = -130.085 uV, v_off_fin = -121.338 uV 14:47:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.933 uVs 14:47:44 Integrated Voltage Measurement... 14:47:53 Voltage Offset Correction: v_off_ini = -129.254 uV, v_off_fin = -123.149 uV 14:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.185 uVs 14:47:53 Integrated Voltage Measurement... 14:48:02 Voltage Offset Correction: v_off_ini = -111.126 uV, v_off_fin = -120.800 uV 14:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.254 uVs 14:48:02 Integrated Voltage Measurement... 14:48:11 Voltage Offset Correction: v_off_ini = -120.328 uV, v_off_fin = -134.854 uV 14:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.177 uVs 14:48:11 Integrated Voltage Measurement... 14:48:20 Voltage Offset Correction: v_off_ini = -131.959 uV, v_off_fin = -128.186 uV 14:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.136 uVs 14:48:24 I1X Average and RMS of Measurements VT = -148.130 +- 6.338 uVs I1X = 29.627 +- 1.269 uTm 14:48:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = -125.038 uV, v_off_fin = -140.601 uV 14:48:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.844 uVs 14:48:40 Integrated Voltage Measurement... 14:48:49 Voltage Offset Correction: v_off_ini = -138.352 uV, v_off_fin = -109.344 uV 14:48:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.123 uVs 14:48:49 Integrated Voltage Measurement... 14:48:58 Voltage Offset Correction: v_off_ini = -139.973 uV, v_off_fin = -141.799 uV 14:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.877 uVs 14:48:58 Integrated Voltage Measurement... 14:49:07 Voltage Offset Correction: v_off_ini = -131.139 uV, v_off_fin = -113.438 uV 14:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.043 uVs 14:49:07 Integrated Voltage Measurement... 14:49:16 Voltage Offset Correction: v_off_ini = -132.146 uV, v_off_fin = -133.426 uV 14:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.911 uVs 14:49:16 Integrated Voltage Measurement... 14:49:25 Voltage Offset Correction: v_off_ini = -128.795 uV, v_off_fin = -112.928 uV 14:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.852 uVs 14:49:29 I1Y Average and RMS of Measurements VT = -293.108 +- 1.908 uVs I1Y = -58.622 +- 0.382 uTm 14:49:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:49:37 Integrated Voltage Measurement... 14:49:46 Voltage Offset Correction: v_off_ini = -137.412 uV, v_off_fin = -134.838 uV 14:49:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -158.381 uVs 14:49:46 Integrated Voltage Measurement... 14:49:55 Voltage Offset Correction: v_off_ini = -129.152 uV, v_off_fin = -123.448 uV 14:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.533 uVs 14:49:55 Integrated Voltage Measurement... 14:50:04 Voltage Offset Correction: v_off_ini = -126.254 uV, v_off_fin = -129.594 uV 14:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.598 uVs 14:50:04 Integrated Voltage Measurement... 14:50:13 Voltage Offset Correction: v_off_ini = -126.310 uV, v_off_fin = -121.124 uV 14:50:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.216 uVs 14:50:13 Integrated Voltage Measurement... 14:50:22 Voltage Offset Correction: v_off_ini = -142.017 uV, v_off_fin = -157.380 uV 14:50:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -149.456 uVs 14:50:22 Integrated Voltage Measurement... 14:50:31 Voltage Offset Correction: v_off_ini = -141.155 uV, v_off_fin = -134.629 uV 14:50:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.622 uVs 14:50:33 I2X Average and RMS of Measurements VT = -141.968 +- 2.313 uVs I2X = 13.061 +- 0.213 uTm^2 14:50:39 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:50:41 Integrated Voltage Measurement... 14:50:50 Voltage Offset Correction: v_off_ini = -150.171 uV, v_off_fin = -144.430 uV 14:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.207 uVs 14:50:50 Integrated Voltage Measurement... 14:50:59 Voltage Offset Correction: v_off_ini = -150.011 uV, v_off_fin = -145.897 uV 14:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.720 uVs 14:50:59 Integrated Voltage Measurement... 14:51:08 Voltage Offset Correction: v_off_ini = -136.994 uV, v_off_fin = -144.851 uV 14:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.438 uVs 14:51:08 Integrated Voltage Measurement... 14:51:17 Voltage Offset Correction: v_off_ini = -140.305 uV, v_off_fin = -127.121 uV 14:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.775 uVs 14:51:17 Integrated Voltage Measurement... 14:51:26 Voltage Offset Correction: v_off_ini = -133.367 uV, v_off_fin = -134.397 uV 14:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.700 uVs 14:51:26 Integrated Voltage Measurement... 14:51:35 Voltage Offset Correction: v_off_ini = -133.469 uV, v_off_fin = -126.683 uV 14:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.291 uVs 14:51:38 I2Y Average and RMS of Measurements VT = -343.188 +- 4.159 uVs I2Y = -31.573 +- 0.383 uTm^2 14:51:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:51:50 Integrated Voltage Measurement... 14:51:59 Voltage Offset Correction: v_off_ini = -137.372 uV, v_off_fin = -158.623 uV 14:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -141.003 uVs 14:51:59 Integrated Voltage Measurement... 14:52:08 Voltage Offset Correction: v_off_ini = -142.231 uV, v_off_fin = -126.797 uV 14:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.263 uVs 14:52:08 Integrated Voltage Measurement... 14:52:17 Voltage Offset Correction: v_off_ini = -127.950 uV, v_off_fin = -132.436 uV 14:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.970 uVs 14:52:17 Integrated Voltage Measurement... 14:52:26 Voltage Offset Correction: v_off_ini = -139.376 uV, v_off_fin = -126.760 uV 14:52:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.570 uVs 14:52:26 Integrated Voltage Measurement... 14:52:35 Voltage Offset Correction: v_off_ini = -133.151 uV, v_off_fin = -130.125 uV 14:52:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.194 uVs 14:52:35 Integrated Voltage Measurement... 14:52:44 Voltage Offset Correction: v_off_ini = -122.457 uV, v_off_fin = -124.366 uV 14:52:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.511 uVs 14:52:48 I1X Average and RMS of Measurements VT = -156.419 +- 4.261 uVs I1X = 31.284 +- 0.852 uTm 14:52:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:52:55 Integrated Voltage Measurement... 14:53:04 Voltage Offset Correction: v_off_ini = -138.523 uV, v_off_fin = -153.519 uV 14:53:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.654 uVs 14:53:04 Integrated Voltage Measurement... 14:53:13 Voltage Offset Correction: v_off_ini = -145.220 uV, v_off_fin = -133.484 uV 14:53:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 255.118 uVs 14:53:13 Integrated Voltage Measurement... 14:53:22 Voltage Offset Correction: v_off_ini = -140.319 uV, v_off_fin = -156.167 uV 14:53:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.633 uVs 14:53:22 Integrated Voltage Measurement... 14:53:31 Voltage Offset Correction: v_off_ini = -124.502 uV, v_off_fin = -121.459 uV 14:53:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.048 uVs 14:53:31 Integrated Voltage Measurement... 14:53:40 Voltage Offset Correction: v_off_ini = -128.244 uV, v_off_fin = -142.378 uV 14:53:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.099 uVs 14:53:40 Integrated Voltage Measurement... 14:53:49 Voltage Offset Correction: v_off_ini = -126.124 uV, v_off_fin = -138.100 uV 14:53:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.246 uVs 14:53:53 I1Y Average and RMS of Measurements VT = -245.466 +- 3.885 uVs I1Y = -49.095 +- 0.779 uTm 14:53:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:53:58 Integrated Voltage Measurement... 14:54:07 Voltage Offset Correction: v_off_ini = -157.894 uV, v_off_fin = -153.483 uV 14:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.624 uVs 14:54:07 Integrated Voltage Measurement... 14:54:16 Voltage Offset Correction: v_off_ini = -153.957 uV, v_off_fin = -130.757 uV 14:54:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.834 uVs 14:54:17 Integrated Voltage Measurement... 14:54:26 Voltage Offset Correction: v_off_ini = -134.896 uV, v_off_fin = -150.784 uV 14:54:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.701 uVs 14:54:26 Integrated Voltage Measurement... 14:54:35 Voltage Offset Correction: v_off_ini = -139.398 uV, v_off_fin = -152.861 uV 14:54:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.083 uVs 14:54:35 Integrated Voltage Measurement... 14:54:44 Voltage Offset Correction: v_off_ini = -154.785 uV, v_off_fin = -164.508 uV 14:54:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.329 uVs 14:54:44 Integrated Voltage Measurement... 14:54:53 Voltage Offset Correction: v_off_ini = -157.093 uV, v_off_fin = -144.218 uV 14:54:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.990 uVs 14:54:55 I2X Average and RMS of Measurements VT = -136.594 +- 8.079 uVs I2X = 12.567 +- 0.743 uTm^2 14:54:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:55:00 Integrated Voltage Measurement... 14:55:09 Voltage Offset Correction: v_off_ini = -161.763 uV, v_off_fin = -156.676 uV 14:55:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.755 uVs 14:55:09 Integrated Voltage Measurement... 14:55:18 Voltage Offset Correction: v_off_ini = -164.452 uV, v_off_fin = -161.855 uV 14:55:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.149 uVs 14:55:18 Integrated Voltage Measurement... 14:55:27 Voltage Offset Correction: v_off_ini = -164.910 uV, v_off_fin = -181.932 uV 14:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.180 uVs 14:55:27 Integrated Voltage Measurement... 14:55:36 Voltage Offset Correction: v_off_ini = -166.339 uV, v_off_fin = -181.388 uV 14:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.171 uVs 14:55:36 Integrated Voltage Measurement... 14:55:45 Voltage Offset Correction: v_off_ini = -190.366 uV, v_off_fin = -178.168 uV 14:55:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.742 uVs 14:55:45 Integrated Voltage Measurement... 14:55:54 Voltage Offset Correction: v_off_ini = -172.012 uV, v_off_fin = -183.851 uV 14:55:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.154 uVs 14:55:57 I2Y Average and RMS of Measurements VT = -301.692 +- 2.976 uVs I2Y = -27.756 +- 0.274 uTm^2 14:56:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:56:05 Integrated Voltage Measurement... 14:56:14 Voltage Offset Correction: v_off_ini = -187.397 uV, v_off_fin = -199.364 uV 14:56:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.656 uVs 14:56:15 Integrated Voltage Measurement... 14:56:23 Voltage Offset Correction: v_off_ini = -201.375 uV, v_off_fin = -205.146 uV 14:56:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.724 uVs 14:56:24 Integrated Voltage Measurement... 14:56:33 Voltage Offset Correction: v_off_ini = -209.669 uV, v_off_fin = -202.531 uV 14:56:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.180 uVs 14:56:33 Integrated Voltage Measurement... 14:56:42 Voltage Offset Correction: v_off_ini = -196.864 uV, v_off_fin = -194.897 uV 14:56:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.707 uVs 14:56:42 Integrated Voltage Measurement... 14:56:51 Voltage Offset Correction: v_off_ini = -192.871 uV, v_off_fin = -202.151 uV 14:56:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.400 uVs 14:56:51 Integrated Voltage Measurement... 14:57:00 Voltage Offset Correction: v_off_ini = -204.412 uV, v_off_fin = -197.728 uV 14:57:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.560 uVs 14:57:04 I1X Average and RMS of Measurements VT = -142.704 +- 4.237 uVs I1X = 28.541 +- 0.847 uTm 14:57:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:57:11 Integrated Voltage Measurement... 14:57:20 Voltage Offset Correction: v_off_ini = -191.470 uV, v_off_fin = -203.654 uV 14:57:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.449 uVs 14:57:20 Integrated Voltage Measurement... 14:57:29 Voltage Offset Correction: v_off_ini = -201.683 uV, v_off_fin = -178.470 uV 14:57:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.322 uVs 14:57:29 Integrated Voltage Measurement... 14:57:38 Voltage Offset Correction: v_off_ini = -188.618 uV, v_off_fin = -195.549 uV 14:57:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.984 uVs 14:57:38 Integrated Voltage Measurement... 14:57:47 Voltage Offset Correction: v_off_ini = -183.325 uV, v_off_fin = -175.448 uV 14:57:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.252 uVs 14:57:47 Integrated Voltage Measurement... 14:57:56 Voltage Offset Correction: v_off_ini = -188.225 uV, v_off_fin = -210.388 uV 14:57:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.675 uVs 14:57:56 Integrated Voltage Measurement... 14:58:05 Voltage Offset Correction: v_off_ini = -181.079 uV, v_off_fin = -168.017 uV 14:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.129 uVs 14:58:09 I1Y Average and RMS of Measurements VT = -260.469 +- 6.898 uVs I1Y = -52.094 +- 1.380 uTm 14:58:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:58:14 Integrated Voltage Measurement... 14:58:23 Voltage Offset Correction: v_off_ini = -184.891 uV, v_off_fin = -190.363 uV 14:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.766 uVs 14:58:23 Integrated Voltage Measurement... 14:58:32 Voltage Offset Correction: v_off_ini = -175.854 uV, v_off_fin = -179.666 uV 14:58:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.777 uVs 14:58:32 Integrated Voltage Measurement... 14:58:41 Voltage Offset Correction: v_off_ini = -164.417 uV, v_off_fin = -191.807 uV 14:58:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.067 uVs 14:58:41 Integrated Voltage Measurement... 14:58:50 Voltage Offset Correction: v_off_ini = -180.884 uV, v_off_fin = -162.578 uV 14:58:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.776 uVs 14:58:50 Integrated Voltage Measurement... 14:58:59 Voltage Offset Correction: v_off_ini = -174.713 uV, v_off_fin = -186.124 uV 14:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.032 uVs 14:58:59 Integrated Voltage Measurement... 14:59:08 Voltage Offset Correction: v_off_ini = -165.277 uV, v_off_fin = -168.107 uV 14:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.134 uVs 14:59:11 I2X Average and RMS of Measurements VT = -128.425 +- 2.820 uVs I2X = 11.816 +- 0.260 uTm^2 14:59:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:59:16 Integrated Voltage Measurement... 14:59:25 Voltage Offset Correction: v_off_ini = -179.533 uV, v_off_fin = -186.739 uV 14:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.485 uVs 14:59:25 Integrated Voltage Measurement... 14:59:34 Voltage Offset Correction: v_off_ini = -182.986 uV, v_off_fin = -191.746 uV 14:59:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.984 uVs 14:59:34 Integrated Voltage Measurement... 14:59:43 Voltage Offset Correction: v_off_ini = -180.062 uV, v_off_fin = -193.357 uV 14:59:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.653 uVs 14:59:43 Integrated Voltage Measurement... 14:59:52 Voltage Offset Correction: v_off_ini = -181.339 uV, v_off_fin = -188.131 uV 14:59:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.514 uVs 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = -205.241 uV, v_off_fin = -196.221 uV 15:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.914 uVs 15:00:01 Integrated Voltage Measurement... 15:00:10 Voltage Offset Correction: v_off_ini = -193.345 uV, v_off_fin = -183.024 uV 15:00:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.004 uVs 15:00:12 I2Y Average and RMS of Measurements VT = -294.759 +- 6.586 uVs I2Y = -27.118 +- 0.606 uTm^2 15:00:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:21 Integrated Voltage Measurement... 15:00:30 Voltage Offset Correction: v_off_ini = -170.122 uV, v_off_fin = -177.801 uV 15:00:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.341 uVs 15:00:30 Integrated Voltage Measurement... 15:00:39 Voltage Offset Correction: v_off_ini = -182.879 uV, v_off_fin = -176.347 uV 15:00:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.353 uVs 15:00:39 Integrated Voltage Measurement... 15:00:48 Voltage Offset Correction: v_off_ini = -197.173 uV, v_off_fin = -194.623 uV 15:00:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.700 uVs 15:00:48 Integrated Voltage Measurement... 15:00:57 Voltage Offset Correction: v_off_ini = -194.417 uV, v_off_fin = -180.690 uV 15:00:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.965 uVs 15:00:57 Integrated Voltage Measurement... 15:01:06 Voltage Offset Correction: v_off_ini = -185.979 uV, v_off_fin = -190.463 uV 15:01:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.554 uVs 15:01:06 Integrated Voltage Measurement... 15:01:15 Voltage Offset Correction: v_off_ini = -180.210 uV, v_off_fin = -170.547 uV 15:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.956 uVs 15:01:19 I1X Average and RMS of Measurements VT = -135.478 +- 5.430 uVs I1X = 27.096 +- 1.085 uTm 15:01:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:26 Integrated Voltage Measurement... 15:01:35 Voltage Offset Correction: v_off_ini = -181.988 uV, v_off_fin = -182.787 uV 15:01:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.165 uVs 15:01:35 Integrated Voltage Measurement... 15:01:44 Voltage Offset Correction: v_off_ini = -182.269 uV, v_off_fin = -170.350 uV 15:01:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.707 uVs 15:01:44 Integrated Voltage Measurement... 15:01:53 Voltage Offset Correction: v_off_ini = -184.439 uV, v_off_fin = -192.544 uV 15:01:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.918 uVs 15:01:53 Integrated Voltage Measurement... 15:02:02 Voltage Offset Correction: v_off_ini = -193.035 uV, v_off_fin = -177.268 uV 15:02:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.988 uVs 15:02:02 Integrated Voltage Measurement... 15:02:11 Voltage Offset Correction: v_off_ini = -194.776 uV, v_off_fin = -203.747 uV 15:02:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.236 uVs 15:02:11 Integrated Voltage Measurement... 15:02:20 Voltage Offset Correction: v_off_ini = -188.745 uV, v_off_fin = -184.370 uV 15:02:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.605 uVs 15:02:24 I1Y Average and RMS of Measurements VT = -259.103 +- 3.092 uVs I1Y = -51.821 +- 0.618 uTm 15:02:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:29 Integrated Voltage Measurement... 15:02:38 Voltage Offset Correction: v_off_ini = -180.148 uV, v_off_fin = -188.113 uV 15:02:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.893 uVs 15:02:38 Integrated Voltage Measurement... 15:02:47 Voltage Offset Correction: v_off_ini = -173.407 uV, v_off_fin = -157.661 uV 15:02:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.564 uVs 15:02:47 Integrated Voltage Measurement... 15:02:56 Voltage Offset Correction: v_off_ini = -177.744 uV, v_off_fin = -182.440 uV 15:02:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.890 uVs 15:02:56 Integrated Voltage Measurement... 15:03:05 Voltage Offset Correction: v_off_ini = -184.133 uV, v_off_fin = -189.899 uV 15:03:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.130 uVs 15:03:05 Integrated Voltage Measurement... 15:03:14 Voltage Offset Correction: v_off_ini = -188.284 uV, v_off_fin = -212.277 uV 15:03:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.641 uVs 15:03:14 Integrated Voltage Measurement... 15:03:23 Voltage Offset Correction: v_off_ini = -204.675 uV, v_off_fin = -186.542 uV 15:03:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.122 uVs 15:03:26 I2X Average and RMS of Measurements VT = -124.873 +- 2.743 uVs I2X = 11.489 +- 0.252 uTm^2 15:03:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:31 Integrated Voltage Measurement... 15:03:40 Voltage Offset Correction: v_off_ini = -202.451 uV, v_off_fin = -194.148 uV 15:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.774 uVs 15:03:40 Integrated Voltage Measurement... 15:03:49 Voltage Offset Correction: v_off_ini = -195.085 uV, v_off_fin = -198.708 uV 15:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.616 uVs 15:03:49 Integrated Voltage Measurement... 15:03:58 Voltage Offset Correction: v_off_ini = -200.435 uV, v_off_fin = -194.810 uV 15:03:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.305 uVs 15:03:58 Integrated Voltage Measurement... 15:04:07 Voltage Offset Correction: v_off_ini = -196.608 uV, v_off_fin = -202.469 uV 15:04:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.700 uVs 15:04:07 Integrated Voltage Measurement... 15:04:16 Voltage Offset Correction: v_off_ini = -218.193 uV, v_off_fin = -207.530 uV 15:04:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.380 uVs 15:04:16 Integrated Voltage Measurement... 15:04:25 Voltage Offset Correction: v_off_ini = -197.258 uV, v_off_fin = -195.006 uV 15:04:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.060 uVs 15:04:27 I2Y Average and RMS of Measurements VT = -290.806 +- 5.018 uVs I2Y = -26.754 +- 0.462 uTm^2 15:04:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:04:36 Integrated Voltage Measurement... 15:04:45 Voltage Offset Correction: v_off_ini = -195.923 uV, v_off_fin = -204.760 uV 15:04:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.348 uVs 15:04:45 Integrated Voltage Measurement... 15:04:54 Voltage Offset Correction: v_off_ini = -204.705 uV, v_off_fin = -197.334 uV 15:04:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.939 uVs 15:04:54 Integrated Voltage Measurement... 15:05:03 Voltage Offset Correction: v_off_ini = -185.809 uV, v_off_fin = -198.244 uV 15:05:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.591 uVs 15:05:03 Integrated Voltage Measurement... 15:05:12 Voltage Offset Correction: v_off_ini = -194.522 uV, v_off_fin = -192.979 uV 15:05:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.807 uVs 15:05:12 Integrated Voltage Measurement... 15:05:21 Voltage Offset Correction: v_off_ini = -198.877 uV, v_off_fin = -198.372 uV 15:05:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.907 uVs 15:05:21 Integrated Voltage Measurement... 15:05:30 Voltage Offset Correction: v_off_ini = -194.240 uV, v_off_fin = -187.788 uV 15:05:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.609 uVs 15:05:34 I1X Average and RMS of Measurements VT = -127.200 +- 5.713 uVs I1X = 25.441 +- 1.144 uTm 15:05:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:05:41 Integrated Voltage Measurement... 15:05:50 Voltage Offset Correction: v_off_ini = -206.020 uV, v_off_fin = -221.161 uV 15:05:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.583 uVs 15:05:50 Integrated Voltage Measurement... 15:05:59 Voltage Offset Correction: v_off_ini = -200.280 uV, v_off_fin = -198.047 uV 15:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.903 uVs 15:05:59 Integrated Voltage Measurement... 15:06:08 Voltage Offset Correction: v_off_ini = -195.542 uV, v_off_fin = -206.402 uV 15:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.757 uVs 15:06:08 Integrated Voltage Measurement... 15:06:17 Voltage Offset Correction: v_off_ini = -182.677 uV, v_off_fin = -178.128 uV 15:06:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.836 uVs 15:06:17 Integrated Voltage Measurement... 15:06:26 Voltage Offset Correction: v_off_ini = -192.399 uV, v_off_fin = -209.660 uV 15:06:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -270.419 uVs 15:06:26 Integrated Voltage Measurement... 15:06:35 Voltage Offset Correction: v_off_ini = -194.409 uV, v_off_fin = -189.344 uV 15:06:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.220 uVs 15:06:39 I1Y Average and RMS of Measurements VT = -252.286 +- 7.275 uVs I1Y = -50.456 +- 1.453 uTm 15:06:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:06:44 Integrated Voltage Measurement... 15:06:53 Voltage Offset Correction: v_off_ini = -224.076 uV, v_off_fin = -220.926 uV 15:06:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.917 uVs 15:06:53 Integrated Voltage Measurement... 15:07:02 Voltage Offset Correction: v_off_ini = -207.962 uV, v_off_fin = -211.041 uV 15:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.687 uVs 15:07:02 Integrated Voltage Measurement... 15:07:11 Voltage Offset Correction: v_off_ini = -206.257 uV, v_off_fin = -211.885 uV 15:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.634 uVs 15:07:11 Integrated Voltage Measurement... 15:07:20 Voltage Offset Correction: v_off_ini = -213.761 uV, v_off_fin = -212.308 uV 15:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.456 uVs 15:07:20 Integrated Voltage Measurement... 15:07:29 Voltage Offset Correction: v_off_ini = -203.872 uV, v_off_fin = -203.177 uV 15:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.639 uVs 15:07:29 Integrated Voltage Measurement... 15:07:38 Voltage Offset Correction: v_off_ini = -190.677 uV, v_off_fin = -193.776 uV 15:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.935 uVs 15:07:41 I2X Average and RMS of Measurements VT = -110.045 +- 9.218 uVs I2X = 10.124 +- 0.848 uTm^2 15:07:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:07:46 Integrated Voltage Measurement... 15:07:55 Voltage Offset Correction: v_off_ini = -203.309 uV, v_off_fin = -202.366 uV 15:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.376 uVs 15:07:55 Integrated Voltage Measurement... 15:08:04 Voltage Offset Correction: v_off_ini = -206.350 uV, v_off_fin = -209.520 uV 15:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.243 uVs 15:08:04 Integrated Voltage Measurement... 15:08:13 Voltage Offset Correction: v_off_ini = -207.860 uV, v_off_fin = -214.012 uV 15:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.949 uVs 15:08:13 Integrated Voltage Measurement... 15:08:22 Voltage Offset Correction: v_off_ini = -197.057 uV, v_off_fin = -197.721 uV 15:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.830 uVs 15:08:22 Integrated Voltage Measurement... 15:08:31 Voltage Offset Correction: v_off_ini = -199.094 uV, v_off_fin = -208.155 uV 15:08:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.440 uVs 15:08:31 Integrated Voltage Measurement... 15:08:40 Voltage Offset Correction: v_off_ini = -206.624 uV, v_off_fin = -196.788 uV 15:08:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.942 uVs 15:08:42 I2Y Average and RMS of Measurements VT = -299.297 +- 2.786 uVs I2Y = -27.535 +- 0.256 uTm^2 15:08:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = -192.597 uV, v_off_fin = -200.891 uV 15:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.456 uVs 15:09:00 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = -205.861 uV, v_off_fin = -193.921 uV 15:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.944 uVs 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = -202.734 uV, v_off_fin = -204.846 uV 15:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.816 uVs 15:09:18 Integrated Voltage Measurement... 15:09:27 Voltage Offset Correction: v_off_ini = -206.141 uV, v_off_fin = -205.266 uV 15:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.399 uVs 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = -190.288 uV, v_off_fin = -192.950 uV 15:09:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.472 uVs 15:09:36 Integrated Voltage Measurement... 15:09:45 Voltage Offset Correction: v_off_ini = -197.208 uV, v_off_fin = -183.732 uV 15:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.671 uVs 15:09:49 I1X Average and RMS of Measurements VT = -112.793 +- 6.331 uVs I1X = 22.559 +- 1.266 uTm 15:09:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:09:56 Integrated Voltage Measurement... 15:10:05 Voltage Offset Correction: v_off_ini = -182.638 uV, v_off_fin = -193.489 uV 15:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -244.527 uVs 15:10:05 Integrated Voltage Measurement... 15:10:14 Voltage Offset Correction: v_off_ini = -162.939 uV, v_off_fin = -160.479 uV 15:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.971 uVs 15:10:14 Integrated Voltage Measurement... 15:10:23 Voltage Offset Correction: v_off_ini = -159.363 uV, v_off_fin = -170.525 uV 15:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -247.957 uVs 15:10:23 Integrated Voltage Measurement... 15:10:32 Voltage Offset Correction: v_off_ini = -166.805 uV, v_off_fin = -157.101 uV 15:10:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 260.727 uVs 15:10:32 Integrated Voltage Measurement... 15:10:41 Voltage Offset Correction: v_off_ini = -169.801 uV, v_off_fin = -180.200 uV 15:10:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -263.502 uVs 15:10:41 Integrated Voltage Measurement... 15:10:50 Voltage Offset Correction: v_off_ini = -174.318 uV, v_off_fin = -165.461 uV 15:10:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 284.707 uVs 15:10:54 I1Y Average and RMS of Measurements VT = -259.565 +- 10.416 uVs I1Y = -51.908 +- 2.083 uTm 15:10:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:10:59 Integrated Voltage Measurement... 15:11:08 Voltage Offset Correction: v_off_ini = -184.894 uV, v_off_fin = -184.583 uV 15:11:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.099 uVs 15:11:08 Integrated Voltage Measurement... 15:11:17 Voltage Offset Correction: v_off_ini = -175.042 uV, v_off_fin = -164.977 uV 15:11:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.702 uVs 15:11:17 Integrated Voltage Measurement... 15:11:26 Voltage Offset Correction: v_off_ini = -181.112 uV, v_off_fin = -188.152 uV 15:11:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.060 uVs 15:11:26 Integrated Voltage Measurement... 15:11:35 Voltage Offset Correction: v_off_ini = -179.357 uV, v_off_fin = -178.318 uV 15:11:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.630 uVs 15:11:35 Integrated Voltage Measurement... 15:11:44 Voltage Offset Correction: v_off_ini = -179.011 uV, v_off_fin = -181.991 uV 15:11:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.930 uVs 15:11:44 Integrated Voltage Measurement... 15:11:53 Voltage Offset Correction: v_off_ini = -181.767 uV, v_off_fin = -175.369 uV 15:11:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.074 uVs 15:11:56 I2X Average and RMS of Measurements VT = -97.916 +- 1.501 uVs I2X = 9.008 +- 0.138 uTm^2 15:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:12:01 Integrated Voltage Measurement... 15:12:10 Voltage Offset Correction: v_off_ini = -191.082 uV, v_off_fin = -200.552 uV 15:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.385 uVs 15:12:10 Integrated Voltage Measurement... 15:12:19 Voltage Offset Correction: v_off_ini = -188.707 uV, v_off_fin = -185.210 uV 15:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.290 uVs 15:12:19 Integrated Voltage Measurement... 15:12:28 Voltage Offset Correction: v_off_ini = -193.405 uV, v_off_fin = -193.118 uV 15:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.620 uVs 15:12:28 Integrated Voltage Measurement... 15:12:37 Voltage Offset Correction: v_off_ini = -188.705 uV, v_off_fin = -192.957 uV 15:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.114 uVs 15:12:37 Integrated Voltage Measurement... 15:12:46 Voltage Offset Correction: v_off_ini = -196.263 uV, v_off_fin = -191.897 uV 15:12:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.919 uVs 15:12:46 Integrated Voltage Measurement... 15:12:55 Voltage Offset Correction: v_off_ini = -182.924 uV, v_off_fin = -190.178 uV 15:12:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.094 uVs 15:12:57 I2Y Average and RMS of Measurements VT = -303.070 +- 3.046 uVs I2Y = -27.882 +- 0.280 uTm^2 15:13:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:13:19 Integrated Voltage Measurement... 15:13:28 Voltage Offset Correction: v_off_ini = -186.583 uV, v_off_fin = -191.273 uV 15:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -155.703 uVs 15:13:28 Integrated Voltage Measurement... 15:13:37 Voltage Offset Correction: v_off_ini = -180.406 uV, v_off_fin = -186.176 uV 15:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.246 uVs 15:13:37 Integrated Voltage Measurement... 15:13:46 Voltage Offset Correction: v_off_ini = -186.317 uV, v_off_fin = -183.657 uV 15:13:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.496 uVs 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = -183.172 uV, v_off_fin = -174.389 uV 15:13:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.474 uVs 15:13:55 Integrated Voltage Measurement... 15:14:04 Voltage Offset Correction: v_off_ini = -200.389 uV, v_off_fin = -190.592 uV 15:14:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.302 uVs 15:14:04 Integrated Voltage Measurement... 15:14:13 Voltage Offset Correction: v_off_ini = -185.991 uV, v_off_fin = -177.907 uV 15:14:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.219 uVs 15:14:17 I1X Average and RMS of Measurements VT = -146.073 +- 4.243 uVs I1X = 29.215 +- 0.849 uTm 15:14:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:14:24 Integrated Voltage Measurement... 15:14:32 Voltage Offset Correction: v_off_ini = -187.936 uV, v_off_fin = -194.437 uV 15:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.975 uVs 15:14:33 Integrated Voltage Measurement... 15:14:41 Voltage Offset Correction: v_off_ini = -191.542 uV, v_off_fin = -181.932 uV 15:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.220 uVs 15:14:42 Integrated Voltage Measurement... 15:14:50 Voltage Offset Correction: v_off_ini = -175.710 uV, v_off_fin = -198.972 uV 15:14:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.073 uVs 15:14:51 Integrated Voltage Measurement... 15:14:59 Voltage Offset Correction: v_off_ini = -188.772 uV, v_off_fin = -173.507 uV 15:15:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.468 uVs 15:15:00 Integrated Voltage Measurement... 15:15:08 Voltage Offset Correction: v_off_ini = -189.971 uV, v_off_fin = -206.655 uV 15:15:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.044 uVs 15:15:09 Integrated Voltage Measurement... 15:15:17 Voltage Offset Correction: v_off_ini = -199.708 uV, v_off_fin = -193.533 uV 15:15:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.445 uVs 15:15:22 I1Y Average and RMS of Measurements VT = -223.204 +- 7.079 uVs I1Y = -44.641 +- 1.416 uTm 15:15:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:15:29 Integrated Voltage Measurement... 15:15:38 Voltage Offset Correction: v_off_ini = -185.494 uV, v_off_fin = -196.908 uV 15:15:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.087 uVs 15:15:38 Integrated Voltage Measurement... 15:15:47 Voltage Offset Correction: v_off_ini = -187.014 uV, v_off_fin = -183.269 uV 15:15:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.799 uVs 15:15:47 Integrated Voltage Measurement... 15:15:56 Voltage Offset Correction: v_off_ini = -199.487 uV, v_off_fin = -198.860 uV 15:15:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.194 uVs 15:15:56 Integrated Voltage Measurement... 15:16:05 Voltage Offset Correction: v_off_ini = -183.163 uV, v_off_fin = -167.280 uV 15:16:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.333 uVs 15:16:05 Integrated Voltage Measurement... 15:16:14 Voltage Offset Correction: v_off_ini = -174.980 uV, v_off_fin = -197.270 uV 15:16:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.380 uVs 15:16:15 Integrated Voltage Measurement... 15:16:23 Voltage Offset Correction: v_off_ini = -182.861 uV, v_off_fin = -168.836 uV 15:16:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.819 uVs 15:16:26 I2X Average and RMS of Measurements VT = -122.102 +- 2.807 uVs I2X = 11.233 +- 0.258 uTm^2 15:16:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:16:34 Integrated Voltage Measurement... 15:16:43 Voltage Offset Correction: v_off_ini = -172.657 uV, v_off_fin = -164.070 uV 15:16:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.454 uVs 15:16:43 Integrated Voltage Measurement... 15:16:52 Voltage Offset Correction: v_off_ini = -178.426 uV, v_off_fin = -174.930 uV 15:16:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.206 uVs 15:16:52 Integrated Voltage Measurement... 15:17:01 Voltage Offset Correction: v_off_ini = -165.862 uV, v_off_fin = -169.784 uV 15:17:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.193 uVs 15:17:01 Integrated Voltage Measurement... 15:17:10 Voltage Offset Correction: v_off_ini = -177.715 uV, v_off_fin = -177.834 uV 15:17:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.817 uVs 15:17:10 Integrated Voltage Measurement... 15:17:19 Voltage Offset Correction: v_off_ini = -190.595 uV, v_off_fin = -178.981 uV 15:17:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.569 uVs 15:17:19 Integrated Voltage Measurement... 15:17:28 Voltage Offset Correction: v_off_ini = -182.655 uV, v_off_fin = -184.984 uV 15:17:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.157 uVs 15:17:30 I2Y Average and RMS of Measurements VT = -248.899 +- 4.676 uVs I2Y = -22.899 +- 0.430 uTm^2 15:17:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:17:39 Integrated Voltage Measurement... 15:17:48 Voltage Offset Correction: v_off_ini = -178.510 uV, v_off_fin = -165.323 uV 15:17:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.737 uVs 15:17:48 Integrated Voltage Measurement... 15:17:57 Voltage Offset Correction: v_off_ini = -169.631 uV, v_off_fin = -168.726 uV 15:17:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.161 uVs 15:17:57 Integrated Voltage Measurement... 15:18:06 Voltage Offset Correction: v_off_ini = -166.837 uV, v_off_fin = -182.953 uV 15:18:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.378 uVs 15:18:06 Integrated Voltage Measurement... 15:18:15 Voltage Offset Correction: v_off_ini = -182.874 uV, v_off_fin = -169.364 uV 15:18:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.407 uVs 15:18:15 Integrated Voltage Measurement... 15:18:24 Voltage Offset Correction: v_off_ini = -158.941 uV, v_off_fin = -165.852 uV 15:18:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.556 uVs 15:18:24 Integrated Voltage Measurement... 15:18:33 Voltage Offset Correction: v_off_ini = -157.701 uV, v_off_fin = -156.911 uV 15:18:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.094 uVs 15:18:37 I1X Average and RMS of Measurements VT = -150.555 +- 3.329 uVs I1X = 30.112 +- 0.666 uTm 15:18:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:18:44 Integrated Voltage Measurement... 15:18:53 Voltage Offset Correction: v_off_ini = -163.369 uV, v_off_fin = -170.186 uV 15:18:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.243 uVs 15:18:53 Integrated Voltage Measurement... 15:19:02 Voltage Offset Correction: v_off_ini = -164.195 uV, v_off_fin = -165.437 uV 15:19:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.010 uVs 15:19:02 Integrated Voltage Measurement... 15:19:11 Voltage Offset Correction: v_off_ini = -173.880 uV, v_off_fin = -185.006 uV 15:19:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.324 uVs 15:19:11 Integrated Voltage Measurement... 15:19:20 Voltage Offset Correction: v_off_ini = -178.039 uV, v_off_fin = -174.266 uV 15:19:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.588 uVs 15:19:20 Integrated Voltage Measurement... 15:19:29 Voltage Offset Correction: v_off_ini = -181.725 uV, v_off_fin = -192.594 uV 15:19:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.384 uVs 15:19:29 Integrated Voltage Measurement... 15:19:38 Voltage Offset Correction: v_off_ini = -173.846 uV, v_off_fin = -161.377 uV 15:19:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.206 uVs 15:19:42 I1Y Average and RMS of Measurements VT = -247.626 +- 8.787 uVs I1Y = -49.525 +- 1.757 uTm 15:19:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:19:50 Integrated Voltage Measurement... 15:19:59 Voltage Offset Correction: v_off_ini = -180.271 uV, v_off_fin = -184.066 uV 15:19:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.853 uVs 15:19:59 Integrated Voltage Measurement... 15:20:08 Voltage Offset Correction: v_off_ini = -163.877 uV, v_off_fin = -166.066 uV 15:20:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.235 uVs 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = -166.301 uV, v_off_fin = -185.539 uV 15:20:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -144.391 uVs 15:20:17 Integrated Voltage Measurement... 15:20:26 Voltage Offset Correction: v_off_ini = -182.847 uV, v_off_fin = -167.847 uV 15:20:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.141 uVs 15:20:26 Integrated Voltage Measurement... 15:20:35 Voltage Offset Correction: v_off_ini = -187.686 uV, v_off_fin = -188.423 uV 15:20:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.138 uVs 15:20:35 Integrated Voltage Measurement... 15:20:44 Voltage Offset Correction: v_off_ini = -179.097 uV, v_off_fin = -172.661 uV 15:20:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.948 uVs 15:20:46 I2X Average and RMS of Measurements VT = -133.618 +- 6.833 uVs I2X = 12.293 +- 0.629 uTm^2 15:20:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:20:54 Integrated Voltage Measurement... 15:21:03 Voltage Offset Correction: v_off_ini = -165.758 uV, v_off_fin = -164.816 uV 15:21:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.214 uVs 15:21:03 Integrated Voltage Measurement... 15:21:12 Voltage Offset Correction: v_off_ini = -151.625 uV, v_off_fin = -158.997 uV 15:21:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.138 uVs 15:21:12 Integrated Voltage Measurement... 15:21:21 Voltage Offset Correction: v_off_ini = -166.972 uV, v_off_fin = -178.483 uV 15:21:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.925 uVs 15:21:21 Integrated Voltage Measurement... 15:21:30 Voltage Offset Correction: v_off_ini = -177.014 uV, v_off_fin = -171.263 uV 15:21:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.958 uVs 15:21:30 Integrated Voltage Measurement... 15:21:39 Voltage Offset Correction: v_off_ini = -172.639 uV, v_off_fin = -172.378 uV 15:21:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.930 uVs 15:21:39 Integrated Voltage Measurement... 15:21:48 Voltage Offset Correction: v_off_ini = -183.761 uV, v_off_fin = -186.149 uV 15:21:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.260 uVs 15:21:51 I2Y Average and RMS of Measurements VT = -283.904 +- 4.346 uVs I2Y = -26.119 +- 0.400 uTm^2 15:21:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:59 Integrated Voltage Measurement... 15:22:08 Voltage Offset Correction: v_off_ini = -181.917 uV, v_off_fin = -186.025 uV 15:22:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.578 uVs 15:22:08 Integrated Voltage Measurement... 15:22:17 Voltage Offset Correction: v_off_ini = -180.008 uV, v_off_fin = -155.196 uV 15:22:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.090 uVs 15:22:18 Integrated Voltage Measurement... 15:22:26 Voltage Offset Correction: v_off_ini = -147.882 uV, v_off_fin = -154.195 uV 15:22:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.133 uVs 15:22:27 Integrated Voltage Measurement... 15:22:35 Voltage Offset Correction: v_off_ini = -155.646 uV, v_off_fin = -163.587 uV 15:22:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.811 uVs 15:22:36 Integrated Voltage Measurement... 15:22:44 Voltage Offset Correction: v_off_ini = -174.567 uV, v_off_fin = -178.324 uV 15:22:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.323 uVs 15:22:45 Integrated Voltage Measurement... 15:22:53 Voltage Offset Correction: v_off_ini = -162.032 uV, v_off_fin = -162.166 uV 15:22:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.846 uVs 15:22:58 I1X Average and RMS of Measurements VT = -148.964 +- 5.214 uVs I1X = 29.794 +- 1.043 uTm 15:23:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:04 Integrated Voltage Measurement... 15:23:13 Voltage Offset Correction: v_off_ini = -185.526 uV, v_off_fin = -192.011 uV 15:23:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.341 uVs 15:23:13 Integrated Voltage Measurement... 15:23:22 Voltage Offset Correction: v_off_ini = -187.838 uV, v_off_fin = -168.862 uV 15:23:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.924 uVs 15:23:22 Integrated Voltage Measurement... 15:23:31 Voltage Offset Correction: v_off_ini = -149.666 uV, v_off_fin = -159.835 uV 15:23:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.809 uVs 15:23:31 Integrated Voltage Measurement... 15:23:40 Voltage Offset Correction: v_off_ini = -142.982 uV, v_off_fin = -145.072 uV 15:23:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.701 uVs 15:23:40 Integrated Voltage Measurement... 15:23:49 Voltage Offset Correction: v_off_ini = -149.615 uV, v_off_fin = -173.932 uV 15:23:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.149 uVs 15:23:49 Integrated Voltage Measurement... 15:23:58 Voltage Offset Correction: v_off_ini = -187.246 uV, v_off_fin = -177.026 uV 15:23:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.126 uVs 15:24:03 I1Y Average and RMS of Measurements VT = -258.175 +- 2.402 uVs I1Y = -51.636 +- 0.479 uTm 15:24:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:10 Integrated Voltage Measurement... 15:24:19 Voltage Offset Correction: v_off_ini = -172.289 uV, v_off_fin = -180.654 uV 15:24:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -140.571 uVs 15:24:19 Integrated Voltage Measurement... 15:24:28 Voltage Offset Correction: v_off_ini = -169.024 uV, v_off_fin = -161.403 uV 15:24:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.083 uVs 15:24:28 Integrated Voltage Measurement... 15:24:37 Voltage Offset Correction: v_off_ini = -160.334 uV, v_off_fin = -172.034 uV 15:24:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.372 uVs 15:24:37 Integrated Voltage Measurement... 15:24:46 Voltage Offset Correction: v_off_ini = -165.835 uV, v_off_fin = -158.943 uV 15:24:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.050 uVs 15:24:46 Integrated Voltage Measurement... 15:24:55 Voltage Offset Correction: v_off_ini = -166.718 uV, v_off_fin = -181.238 uV 15:24:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.185 uVs 15:24:55 Integrated Voltage Measurement... 15:25:04 Voltage Offset Correction: v_off_ini = -165.937 uV, v_off_fin = -160.911 uV 15:25:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.254 uVs 15:25:07 I2X Average and RMS of Measurements VT = -135.419 +- 11.431 uVs I2X = 12.459 +- 1.052 uTm^2 15:25:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:14 Integrated Voltage Measurement... 15:25:23 Voltage Offset Correction: v_off_ini = -175.718 uV, v_off_fin = -173.259 uV 15:25:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.258 uVs 15:25:23 Integrated Voltage Measurement... 15:25:32 Voltage Offset Correction: v_off_ini = -178.441 uV, v_off_fin = -164.107 uV 15:25:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.299 uVs 15:25:33 Integrated Voltage Measurement... 15:25:41 Voltage Offset Correction: v_off_ini = -159.352 uV, v_off_fin = -157.600 uV 15:25:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.824 uVs 15:25:42 Integrated Voltage Measurement... 15:25:50 Voltage Offset Correction: v_off_ini = -164.682 uV, v_off_fin = -157.221 uV 15:25:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.349 uVs 15:25:51 Integrated Voltage Measurement... 15:26:00 Voltage Offset Correction: v_off_ini = -156.384 uV, v_off_fin = -159.955 uV 15:26:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -293.609 uVs 15:26:00 Integrated Voltage Measurement... 15:26:09 Voltage Offset Correction: v_off_ini = -156.726 uV, v_off_fin = -160.182 uV 15:26:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.878 uVs 15:26:11 I2Y Average and RMS of Measurements VT = -299.703 +- 3.291 uVs I2Y = -27.573 +- 0.302 uTm^2 15:26:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:26:20 Integrated Voltage Measurement... 15:26:29 Voltage Offset Correction: v_off_ini = -161.801 uV, v_off_fin = -165.497 uV 15:26:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -144.215 uVs 15:26:29 Integrated Voltage Measurement... 15:26:38 Voltage Offset Correction: v_off_ini = -159.336 uV, v_off_fin = -151.918 uV 15:26:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 154.062 uVs 15:26:38 Integrated Voltage Measurement... 15:26:47 Voltage Offset Correction: v_off_ini = -168.296 uV, v_off_fin = -171.967 uV 15:26:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.705 uVs 15:26:47 Integrated Voltage Measurement... 15:26:56 Voltage Offset Correction: v_off_ini = -161.595 uV, v_off_fin = -156.785 uV 15:26:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.680 uVs 15:26:56 Integrated Voltage Measurement... 15:27:05 Voltage Offset Correction: v_off_ini = -166.023 uV, v_off_fin = -161.013 uV 15:27:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.413 uVs 15:27:05 Integrated Voltage Measurement... 15:27:14 Voltage Offset Correction: v_off_ini = -167.427 uV, v_off_fin = -156.889 uV 15:27:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 165.288 uVs 15:27:18 I1X Average and RMS of Measurements VT = -150.061 +- 5.208 uVs I1X = 30.014 +- 1.041 uTm 15:27:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:27:25 Integrated Voltage Measurement... 15:27:34 Voltage Offset Correction: v_off_ini = -181.455 uV, v_off_fin = -178.094 uV 15:27:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -274.846 uVs 15:27:34 Integrated Voltage Measurement... 15:27:43 Voltage Offset Correction: v_off_ini = -167.852 uV, v_off_fin = -167.228 uV 15:27:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.380 uVs 15:27:43 Integrated Voltage Measurement... 15:27:52 Voltage Offset Correction: v_off_ini = -159.422 uV, v_off_fin = -172.583 uV 15:27:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -290.071 uVs 15:27:52 Integrated Voltage Measurement... 15:28:01 Voltage Offset Correction: v_off_ini = -167.918 uV, v_off_fin = -159.093 uV 15:28:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.742 uVs 15:28:01 Integrated Voltage Measurement... 15:28:10 Voltage Offset Correction: v_off_ini = -174.895 uV, v_off_fin = -188.074 uV 15:28:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.637 uVs 15:28:10 Integrated Voltage Measurement... 15:28:19 Voltage Offset Correction: v_off_ini = -171.867 uV, v_off_fin = -157.042 uV 15:28:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.573 uVs 15:28:23 I1Y Average and RMS of Measurements VT = -279.875 +- 1.607 uVs I1Y = -55.976 +- 0.322 uTm 15:28:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:28:31 Integrated Voltage Measurement... 15:28:40 Voltage Offset Correction: v_off_ini = -173.216 uV, v_off_fin = -184.142 uV 15:28:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.888 uVs 15:28:40 Integrated Voltage Measurement... 15:28:49 Voltage Offset Correction: v_off_ini = -179.930 uV, v_off_fin = -169.477 uV 15:28:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.689 uVs 15:28:49 Integrated Voltage Measurement... 15:28:58 Voltage Offset Correction: v_off_ini = -175.586 uV, v_off_fin = -182.753 uV 15:28:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.337 uVs 15:28:58 Integrated Voltage Measurement... 15:29:07 Voltage Offset Correction: v_off_ini = -173.667 uV, v_off_fin = -169.002 uV 15:29:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.114 uVs 15:29:07 Integrated Voltage Measurement... 15:29:16 Voltage Offset Correction: v_off_ini = -170.094 uV, v_off_fin = -179.727 uV 15:29:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.694 uVs 15:29:16 Integrated Voltage Measurement... 15:29:25 Voltage Offset Correction: v_off_ini = -174.719 uV, v_off_fin = -152.212 uV 15:29:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.410 uVs 15:29:28 I2X Average and RMS of Measurements VT = -144.855 +- 2.559 uVs I2X = 13.327 +- 0.235 uTm^2 15:29:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:29:35 Integrated Voltage Measurement... 15:29:44 Voltage Offset Correction: v_off_ini = -163.857 uV, v_off_fin = -161.605 uV 15:29:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.542 uVs 15:29:44 Integrated Voltage Measurement... 15:29:53 Voltage Offset Correction: v_off_ini = -163.371 uV, v_off_fin = -177.513 uV 15:29:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.679 uVs 15:29:53 Integrated Voltage Measurement... 15:30:02 Voltage Offset Correction: v_off_ini = -164.213 uV, v_off_fin = -169.308 uV 15:30:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.176 uVs 15:30:02 Integrated Voltage Measurement... 15:30:11 Voltage Offset Correction: v_off_ini = -175.144 uV, v_off_fin = -168.034 uV 15:30:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.768 uVs 15:30:11 Integrated Voltage Measurement... 15:30:20 Voltage Offset Correction: v_off_ini = -174.291 uV, v_off_fin = -179.702 uV 15:30:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.350 uVs 15:30:21 Integrated Voltage Measurement... 15:30:30 Voltage Offset Correction: v_off_ini = -184.763 uV, v_off_fin = -176.397 uV 15:30:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.807 uVs 15:30:32 I2Y Average and RMS of Measurements VT = -322.387 +- 5.629 uVs I2Y = -29.660 +- 0.518 uTm^2 15:30:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:30:41 Integrated Voltage Measurement... 15:30:50 Voltage Offset Correction: v_off_ini = -159.238 uV, v_off_fin = -168.230 uV 15:30:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -170.666 uVs 15:30:50 Integrated Voltage Measurement... 15:30:59 Voltage Offset Correction: v_off_ini = -163.694 uV, v_off_fin = -158.870 uV 15:30:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.683 uVs 15:30:59 Integrated Voltage Measurement... 15:31:08 Voltage Offset Correction: v_off_ini = -167.722 uV, v_off_fin = -166.556 uV 15:31:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.407 uVs 15:31:08 Integrated Voltage Measurement... 15:31:17 Voltage Offset Correction: v_off_ini = -170.343 uV, v_off_fin = -157.727 uV 15:31:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.547 uVs 15:31:17 Integrated Voltage Measurement... 15:31:26 Voltage Offset Correction: v_off_ini = -179.221 uV, v_off_fin = -169.157 uV 15:31:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.538 uVs 15:31:26 Integrated Voltage Measurement... 15:31:35 Voltage Offset Correction: v_off_ini = -165.422 uV, v_off_fin = -162.286 uV 15:31:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.641 uVs 15:31:39 I1X Average and RMS of Measurements VT = -157.247 +- 7.216 uVs I1X = 31.450 +- 1.444 uTm 15:31:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:31:46 Integrated Voltage Measurement... 15:31:55 Voltage Offset Correction: v_off_ini = -172.850 uV, v_off_fin = -183.455 uV 15:31:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -295.724 uVs 15:31:55 Integrated Voltage Measurement... 15:32:04 Voltage Offset Correction: v_off_ini = -161.869 uV, v_off_fin = -159.617 uV 15:32:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 316.860 uVs 15:32:04 Integrated Voltage Measurement... 15:32:13 Voltage Offset Correction: v_off_ini = -162.768 uV, v_off_fin = -177.749 uV 15:32:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -286.919 uVs 15:32:13 Integrated Voltage Measurement... 15:32:22 Voltage Offset Correction: v_off_ini = -168.788 uV, v_off_fin = -152.096 uV 15:32:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 298.054 uVs 15:32:22 Integrated Voltage Measurement... 15:32:31 Voltage Offset Correction: v_off_ini = -163.952 uV, v_off_fin = -170.521 uV 15:32:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -307.046 uVs 15:32:31 Integrated Voltage Measurement... 15:32:40 Voltage Offset Correction: v_off_ini = -166.593 uV, v_off_fin = -156.603 uV 15:32:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.296 uVs 15:32:44 I1Y Average and RMS of Measurements VT = -299.983 +- 5.698 uVs I1Y = -59.997 +- 1.140 uTm 15:32:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:32:52 Integrated Voltage Measurement... 15:33:01 Voltage Offset Correction: v_off_ini = -181.397 uV, v_off_fin = -177.663 uV 15:33:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -146.531 uVs 15:33:01 Integrated Voltage Measurement... 15:33:10 Voltage Offset Correction: v_off_ini = -168.507 uV, v_off_fin = -171.518 uV 15:33:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.664 uVs 15:33:10 Integrated Voltage Measurement... 15:33:19 Voltage Offset Correction: v_off_ini = -160.048 uV, v_off_fin = -175.327 uV 15:33:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.712 uVs 15:33:19 Integrated Voltage Measurement... 15:33:28 Voltage Offset Correction: v_off_ini = -166.088 uV, v_off_fin = -154.515 uV 15:33:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.848 uVs 15:33:28 Integrated Voltage Measurement... 15:33:37 Voltage Offset Correction: v_off_ini = -162.789 uV, v_off_fin = -176.162 uV 15:33:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.599 uVs 15:33:37 Integrated Voltage Measurement... 15:33:46 Voltage Offset Correction: v_off_ini = -175.900 uV, v_off_fin = -175.481 uV 15:33:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.657 uVs 15:33:48 I2X Average and RMS of Measurements VT = -144.502 +- 8.213 uVs I2X = 13.294 +- 0.755 uTm^2 15:33:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:33:56 Integrated Voltage Measurement... 15:34:05 Voltage Offset Correction: v_off_ini = -157.317 uV, v_off_fin = -154.204 uV 15:34:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.246 uVs 15:34:05 Integrated Voltage Measurement... 15:34:14 Voltage Offset Correction: v_off_ini = -158.084 uV, v_off_fin = -158.703 uV 15:34:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.939 uVs 15:34:14 Integrated Voltage Measurement... 15:34:23 Voltage Offset Correction: v_off_ini = -157.215 uV, v_off_fin = -169.354 uV 15:34:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.773 uVs 15:34:23 Integrated Voltage Measurement... 15:34:32 Voltage Offset Correction: v_off_ini = -168.340 uV, v_off_fin = -154.088 uV 15:34:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.115 uVs 15:34:32 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = -145.124 uV, v_off_fin = -156.701 uV 15:34:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.545 uVs 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = -156.936 uV, v_off_fin = -153.850 uV 15:34:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.289 uVs 15:34:53 I2Y Average and RMS of Measurements VT = -344.651 +- 7.086 uVs I2Y = -31.708 +- 0.652 uTm^2 15:35:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:35:05 Integrated Voltage Measurement... 15:35:14 Voltage Offset Correction: v_off_ini = -144.847 uV, v_off_fin = -158.628 uV 15:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.266 uVs 15:35:14 Integrated Voltage Measurement... 15:35:23 Voltage Offset Correction: v_off_ini = -168.315 uV, v_off_fin = -169.949 uV 15:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.075 uVs 15:35:23 Integrated Voltage Measurement... 15:35:32 Voltage Offset Correction: v_off_ini = -159.977 uV, v_off_fin = -167.756 uV 15:35:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.209 uVs 15:35:32 Integrated Voltage Measurement... 15:35:41 Voltage Offset Correction: v_off_ini = -160.960 uV, v_off_fin = -165.552 uV 15:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.811 uVs 15:35:41 Integrated Voltage Measurement... 15:35:50 Voltage Offset Correction: v_off_ini = -166.006 uV, v_off_fin = -158.168 uV 15:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.856 uVs 15:35:50 Integrated Voltage Measurement... 15:35:59 Voltage Offset Correction: v_off_ini = -161.332 uV, v_off_fin = -163.689 uV 15:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.044 uVs 15:36:03 I1X Average and RMS of Measurements VT = -156.877 +- 1.011 uVs I1X = 31.376 +- 0.203 uTm 15:36:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:36:10 Integrated Voltage Measurement... 15:36:19 Voltage Offset Correction: v_off_ini = -164.489 uV, v_off_fin = -169.960 uV 15:36:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.147 uVs 15:36:19 Integrated Voltage Measurement... 15:36:28 Voltage Offset Correction: v_off_ini = -160.630 uV, v_off_fin = -162.052 uV 15:36:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.730 uVs 15:36:28 Integrated Voltage Measurement... 15:36:37 Voltage Offset Correction: v_off_ini = -170.074 uV, v_off_fin = -178.430 uV 15:36:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.525 uVs 15:36:37 Integrated Voltage Measurement... 15:36:46 Voltage Offset Correction: v_off_ini = -178.922 uV, v_off_fin = -181.291 uV 15:36:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.072 uVs 15:36:46 Integrated Voltage Measurement... 15:36:55 Voltage Offset Correction: v_off_ini = -170.191 uV, v_off_fin = -176.532 uV 15:36:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.419 uVs 15:36:55 Integrated Voltage Measurement... 15:37:04 Voltage Offset Correction: v_off_ini = -159.967 uV, v_off_fin = -142.984 uV 15:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.506 uVs 15:37:08 I1Y Average and RMS of Measurements VT = -253.566 +- 2.125 uVs I1Y = -50.713 +- 0.425 uTm 15:37:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:37:13 Integrated Voltage Measurement... 15:37:22 Voltage Offset Correction: v_off_ini = -172.762 uV, v_off_fin = -171.323 uV 15:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.785 uVs 15:37:22 Integrated Voltage Measurement... 15:37:31 Voltage Offset Correction: v_off_ini = -154.094 uV, v_off_fin = -147.888 uV 15:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.754 uVs 15:37:31 Integrated Voltage Measurement... 15:37:40 Voltage Offset Correction: v_off_ini = -155.786 uV, v_off_fin = -164.222 uV 15:37:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.644 uVs 15:37:40 Integrated Voltage Measurement... 15:37:49 Voltage Offset Correction: v_off_ini = -156.180 uV, v_off_fin = -159.209 uV 15:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.889 uVs 15:37:49 Integrated Voltage Measurement... 15:37:58 Voltage Offset Correction: v_off_ini = -161.073 uV, v_off_fin = -154.024 uV 15:37:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.773 uVs 15:37:59 Integrated Voltage Measurement... 15:38:07 Voltage Offset Correction: v_off_ini = -148.488 uV, v_off_fin = -141.718 uV 15:38:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.010 uVs 15:38:10 I2X Average and RMS of Measurements VT = -134.976 +- 6.581 uVs I2X = 12.418 +- 0.606 uTm^2 15:38:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:38:15 Integrated Voltage Measurement... 15:38:24 Voltage Offset Correction: v_off_ini = -161.121 uV, v_off_fin = -160.466 uV 15:38:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.840 uVs 15:38:24 Integrated Voltage Measurement... 15:38:33 Voltage Offset Correction: v_off_ini = -170.916 uV, v_off_fin = -165.292 uV 15:38:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.140 uVs 15:38:33 Integrated Voltage Measurement... 15:38:42 Voltage Offset Correction: v_off_ini = -173.022 uV, v_off_fin = -171.885 uV 15:38:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.420 uVs 15:38:42 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = -171.337 uV, v_off_fin = -183.463 uV 15:38:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.360 uVs 15:38:51 Integrated Voltage Measurement... 15:39:00 Voltage Offset Correction: v_off_ini = -160.539 uV, v_off_fin = -171.557 uV 15:39:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.143 uVs 15:39:00 Integrated Voltage Measurement... 15:39:09 Voltage Offset Correction: v_off_ini = -169.099 uV, v_off_fin = -160.525 uV 15:39:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.086 uVs 15:39:12 I2Y Average and RMS of Measurements VT = -294.332 +- 3.344 uVs I2Y = -27.078 +- 0.308 uTm^2 15:39:16 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:39:20 Integrated Voltage Measurement... 15:39:29 Voltage Offset Correction: v_off_ini = -156.335 uV, v_off_fin = -163.176 uV 15:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -152.486 uVs 15:39:29 Integrated Voltage Measurement... 15:39:38 Voltage Offset Correction: v_off_ini = -159.763 uV, v_off_fin = -148.863 uV 15:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.904 uVs 15:39:38 Integrated Voltage Measurement... 15:39:47 Voltage Offset Correction: v_off_ini = -150.552 uV, v_off_fin = -167.025 uV 15:39:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -156.679 uVs 15:39:47 Integrated Voltage Measurement... 15:39:56 Voltage Offset Correction: v_off_ini = -156.490 uV, v_off_fin = -148.027 uV 15:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.793 uVs 15:39:56 Integrated Voltage Measurement... 15:40:05 Voltage Offset Correction: v_off_ini = -155.639 uV, v_off_fin = -155.054 uV 15:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.875 uVs 15:40:05 Integrated Voltage Measurement... 15:40:14 Voltage Offset Correction: v_off_ini = -151.248 uV, v_off_fin = -149.370 uV 15:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.055 uVs 15:40:18 I1X Average and RMS of Measurements VT = -149.799 +- 1.839 uVs I1X = 29.961 +- 0.367 uTm 15:40:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = -153.378 uV, v_off_fin = -179.867 uV 15:40:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.513 uVs 15:40:34 Integrated Voltage Measurement... 15:40:43 Voltage Offset Correction: v_off_ini = -165.912 uV, v_off_fin = -162.883 uV 15:40:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.289 uVs 15:40:43 Integrated Voltage Measurement... 15:40:52 Voltage Offset Correction: v_off_ini = -172.140 uV, v_off_fin = -172.597 uV 15:40:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.087 uVs 15:40:52 Integrated Voltage Measurement... 15:41:01 Voltage Offset Correction: v_off_ini = -165.021 uV, v_off_fin = -163.200 uV 15:41:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.056 uVs 15:41:01 Integrated Voltage Measurement... 15:41:10 Voltage Offset Correction: v_off_ini = -178.182 uV, v_off_fin = -178.783 uV 15:41:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.968 uVs 15:41:10 Integrated Voltage Measurement... 15:41:19 Voltage Offset Correction: v_off_ini = -174.356 uV, v_off_fin = -151.862 uV 15:41:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.759 uVs 15:41:23 I1Y Average and RMS of Measurements VT = -256.945 +- 2.811 uVs I1Y = -51.389 +- 0.562 uTm 15:41:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:41:28 Integrated Voltage Measurement... 15:41:37 Voltage Offset Correction: v_off_ini = -176.459 uV, v_off_fin = -179.712 uV 15:41:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.695 uVs 15:41:37 Integrated Voltage Measurement... 15:41:46 Voltage Offset Correction: v_off_ini = -171.714 uV, v_off_fin = -173.907 uV 15:41:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.190 uVs 15:41:46 Integrated Voltage Measurement... 15:41:55 Voltage Offset Correction: v_off_ini = -185.032 uV, v_off_fin = -191.783 uV 15:41:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.987 uVs 15:41:55 Integrated Voltage Measurement... 15:42:04 Voltage Offset Correction: v_off_ini = -177.318 uV, v_off_fin = -164.835 uV 15:42:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.011 uVs 15:42:04 Integrated Voltage Measurement... 15:42:13 Voltage Offset Correction: v_off_ini = -168.482 uV, v_off_fin = -177.047 uV 15:42:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.248 uVs 15:42:13 Integrated Voltage Measurement... 15:42:22 Voltage Offset Correction: v_off_ini = -161.932 uV, v_off_fin = -164.706 uV 15:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.360 uVs 15:42:25 I2X Average and RMS of Measurements VT = -136.415 +- 8.100 uVs I2X = 12.550 +- 0.745 uTm^2 15:42:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:42:30 Integrated Voltage Measurement... 15:42:39 Voltage Offset Correction: v_off_ini = -166.642 uV, v_off_fin = -177.997 uV 15:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.082 uVs 15:42:39 Integrated Voltage Measurement... 15:42:48 Voltage Offset Correction: v_off_ini = -184.433 uV, v_off_fin = -182.963 uV 15:42:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.980 uVs 15:42:48 Integrated Voltage Measurement... 15:42:57 Voltage Offset Correction: v_off_ini = -175.196 uV, v_off_fin = -189.132 uV 15:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.754 uVs 15:42:57 Integrated Voltage Measurement... 15:43:06 Voltage Offset Correction: v_off_ini = -182.024 uV, v_off_fin = -171.542 uV 15:43:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.069 uVs 15:43:06 Integrated Voltage Measurement... 15:43:15 Voltage Offset Correction: v_off_ini = -168.599 uV, v_off_fin = -172.182 uV 15:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.387 uVs 15:43:15 Integrated Voltage Measurement... 15:43:24 Voltage Offset Correction: v_off_ini = -184.948 uV, v_off_fin = -187.939 uV 15:43:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.176 uVs 15:43:26 I2Y Average and RMS of Measurements VT = -293.908 +- 4.991 uVs I2Y = -27.040 +- 0.459 uTm^2 15:43:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:35 Integrated Voltage Measurement... 15:43:44 Voltage Offset Correction: v_off_ini = -191.628 uV, v_off_fin = -191.628 uV 15:43:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -154.017 uVs 15:43:44 Integrated Voltage Measurement... 15:43:53 Voltage Offset Correction: v_off_ini = -172.033 uV, v_off_fin = -179.754 uV 15:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.824 uVs 15:43:53 Integrated Voltage Measurement... 15:44:02 Voltage Offset Correction: v_off_ini = -181.968 uV, v_off_fin = -189.141 uV 15:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.839 uVs 15:44:02 Integrated Voltage Measurement... 15:44:11 Voltage Offset Correction: v_off_ini = -171.080 uV, v_off_fin = -176.670 uV 15:44:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.310 uVs 15:44:11 Integrated Voltage Measurement... 15:44:20 Voltage Offset Correction: v_off_ini = -168.388 uV, v_off_fin = -176.809 uV 15:44:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.023 uVs 15:44:20 Integrated Voltage Measurement... 15:44:29 Voltage Offset Correction: v_off_ini = -165.319 uV, v_off_fin = -166.176 uV 15:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.056 uVs 15:44:33 I1X Average and RMS of Measurements VT = -148.345 +- 5.357 uVs I1X = 29.670 +- 1.072 uTm 15:44:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:40 Integrated Voltage Measurement... 15:44:49 Voltage Offset Correction: v_off_ini = -158.103 uV, v_off_fin = -166.902 uV 15:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -269.103 uVs 15:44:49 Integrated Voltage Measurement... 15:44:57 Voltage Offset Correction: v_off_ini = -150.985 uV, v_off_fin = -152.046 uV 15:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.796 uVs 15:44:58 Integrated Voltage Measurement... 15:45:06 Voltage Offset Correction: v_off_ini = -162.019 uV, v_off_fin = -181.323 uV 15:45:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.794 uVs 15:45:07 Integrated Voltage Measurement... 15:45:15 Voltage Offset Correction: v_off_ini = -165.676 uV, v_off_fin = -152.437 uV 15:45:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.252 uVs 15:45:16 Integrated Voltage Measurement... 15:45:24 Voltage Offset Correction: v_off_ini = -167.354 uV, v_off_fin = -172.167 uV 15:45:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.200 uVs 15:45:24 Integrated Voltage Measurement... 15:45:33 Voltage Offset Correction: v_off_ini = -165.364 uV, v_off_fin = -148.138 uV 15:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.003 uVs 15:45:38 I1Y Average and RMS of Measurements VT = -261.691 +- 1.265 uVs I1Y = -52.339 +- 0.254 uTm 15:45:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:43 Integrated Voltage Measurement... 15:45:52 Voltage Offset Correction: v_off_ini = -181.913 uV, v_off_fin = -179.180 uV 15:45:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.685 uVs 15:45:52 Integrated Voltage Measurement... 15:46:01 Voltage Offset Correction: v_off_ini = -176.795 uV, v_off_fin = -162.463 uV 15:46:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.944 uVs 15:46:01 Integrated Voltage Measurement... 15:46:10 Voltage Offset Correction: v_off_ini = -159.064 uV, v_off_fin = -168.822 uV 15:46:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.021 uVs 15:46:10 Integrated Voltage Measurement... 15:46:19 Voltage Offset Correction: v_off_ini = -175.917 uV, v_off_fin = -153.036 uV 15:46:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.486 uVs 15:46:19 Integrated Voltage Measurement... 15:46:28 Voltage Offset Correction: v_off_ini = -164.415 uV, v_off_fin = -189.613 uV 15:46:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.075 uVs 15:46:28 Integrated Voltage Measurement... 15:46:37 Voltage Offset Correction: v_off_ini = -159.250 uV, v_off_fin = -158.565 uV 15:46:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.473 uVs 15:46:39 I2X Average and RMS of Measurements VT = -133.447 +- 5.623 uVs I2X = 12.278 +- 0.517 uTm^2 15:46:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = -177.512 uV, v_off_fin = -173.731 uV 15:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.359 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = -175.194 uV, v_off_fin = -179.954 uV 15:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.790 uVs 15:47:02 Integrated Voltage Measurement... 15:47:11 Voltage Offset Correction: v_off_ini = -189.031 uV, v_off_fin = -179.507 uV 15:47:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.937 uVs 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = -173.647 uV, v_off_fin = -176.384 uV 15:47:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.973 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = -186.757 uV, v_off_fin = -174.809 uV 15:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.609 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = -179.982 uV, v_off_fin = -172.927 uV 15:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.699 uVs 15:47:41 I2Y Average and RMS of Measurements VT = -293.061 +- 8.560 uVs I2Y = -26.962 +- 0.788 uTm^2 15:47:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:47:49 Integrated Voltage Measurement... 15:47:58 Voltage Offset Correction: v_off_ini = -179.530 uV, v_off_fin = -184.566 uV 15:47:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -139.266 uVs 15:47:58 Integrated Voltage Measurement... 15:48:07 Voltage Offset Correction: v_off_ini = -155.783 uV, v_off_fin = -157.688 uV 15:48:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.268 uVs 15:48:07 Integrated Voltage Measurement... 15:48:16 Voltage Offset Correction: v_off_ini = -151.608 uV, v_off_fin = -152.044 uV 15:48:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.259 uVs 15:48:16 Integrated Voltage Measurement... 15:48:25 Voltage Offset Correction: v_off_ini = -151.781 uV, v_off_fin = -147.374 uV 15:48:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.144 uVs 15:48:25 Integrated Voltage Measurement... 15:48:34 Voltage Offset Correction: v_off_ini = -159.845 uV, v_off_fin = -159.328 uV 15:48:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.051 uVs 15:48:34 Integrated Voltage Measurement... 15:48:43 Voltage Offset Correction: v_off_ini = -158.471 uV, v_off_fin = -155.238 uV 15:48:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.139 uVs 15:48:47 I1X Average and RMS of Measurements VT = -131.855 +- 2.032 uVs I1X = 26.372 +- 0.406 uTm 15:48:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:48:54 Integrated Voltage Measurement... 15:49:03 Voltage Offset Correction: v_off_ini = -163.878 uV, v_off_fin = -172.688 uV 15:49:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -256.773 uVs 15:49:03 Integrated Voltage Measurement... 15:49:12 Voltage Offset Correction: v_off_ini = -158.754 uV, v_off_fin = -144.164 uV 15:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 252.525 uVs 15:49:12 Integrated Voltage Measurement... 15:49:21 Voltage Offset Correction: v_off_ini = -160.475 uV, v_off_fin = -169.272 uV 15:49:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.830 uVs 15:49:21 Integrated Voltage Measurement... 15:49:30 Voltage Offset Correction: v_off_ini = -156.767 uV, v_off_fin = -144.041 uV 15:49:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.051 uVs 15:49:30 Integrated Voltage Measurement... 15:49:39 Voltage Offset Correction: v_off_ini = -160.423 uV, v_off_fin = -172.505 uV 15:49:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -248.975 uVs 15:49:39 Integrated Voltage Measurement... 15:49:48 Voltage Offset Correction: v_off_ini = -164.918 uV, v_off_fin = -160.844 uV 15:49:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 269.755 uVs 15:49:52 I1Y Average and RMS of Measurements VT = -256.152 +- 2.274 uVs I1Y = -51.225 +- 0.455 uTm 15:49:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:49:57 Integrated Voltage Measurement... 15:50:06 Voltage Offset Correction: v_off_ini = -158.880 uV, v_off_fin = -162.489 uV 15:50:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.540 uVs 15:50:06 Integrated Voltage Measurement... 15:50:15 Voltage Offset Correction: v_off_ini = -149.513 uV, v_off_fin = -141.363 uV 15:50:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.998 uVs 15:50:15 Integrated Voltage Measurement... 15:50:24 Voltage Offset Correction: v_off_ini = -164.155 uV, v_off_fin = -167.398 uV 15:50:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.118 uVs 15:50:25 Integrated Voltage Measurement... 15:50:33 Voltage Offset Correction: v_off_ini = -148.377 uV, v_off_fin = -157.163 uV 15:50:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.854 uVs 15:50:34 Integrated Voltage Measurement... 15:50:43 Voltage Offset Correction: v_off_ini = -171.845 uV, v_off_fin = -180.816 uV 15:50:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.211 uVs 15:50:43 Integrated Voltage Measurement... 15:50:52 Voltage Offset Correction: v_off_ini = -163.741 uV, v_off_fin = -140.785 uV 15:50:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.814 uVs 15:50:54 I2X Average and RMS of Measurements VT = -129.256 +- 7.011 uVs I2X = 11.892 +- 0.645 uTm^2 15:50:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = -156.230 uV, v_off_fin = -163.806 uV 15:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.250 uVs 15:51:08 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = -168.615 uV, v_off_fin = -161.380 uV 15:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.775 uVs 15:51:17 Integrated Voltage Measurement... 15:51:26 Voltage Offset Correction: v_off_ini = -151.782 uV, v_off_fin = -149.037 uV 15:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.034 uVs 15:51:26 Integrated Voltage Measurement... 15:51:35 Voltage Offset Correction: v_off_ini = -156.462 uV, v_off_fin = -153.141 uV 15:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.177 uVs 15:51:35 Integrated Voltage Measurement... 15:51:44 Voltage Offset Correction: v_off_ini = -168.079 uV, v_off_fin = -174.647 uV 15:51:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.373 uVs 15:51:44 Integrated Voltage Measurement... 15:51:53 Voltage Offset Correction: v_off_ini = -172.692 uV, v_off_fin = -163.791 uV 15:51:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.680 uVs 15:51:56 I2Y Average and RMS of Measurements VT = -297.882 +- 6.600 uVs I2Y = -27.405 +- 0.607 uTm^2 15:52:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:52:04 Integrated Voltage Measurement... 15:52:13 Voltage Offset Correction: v_off_ini = -133.776 uV, v_off_fin = -162.700 uV 15:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.759 uVs 15:52:13 Integrated Voltage Measurement... 15:52:22 Voltage Offset Correction: v_off_ini = -151.629 uV, v_off_fin = -153.370 uV 15:52:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.099 uVs 15:52:22 Integrated Voltage Measurement... 15:52:31 Voltage Offset Correction: v_off_ini = -142.697 uV, v_off_fin = -154.428 uV 15:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.730 uVs 15:52:31 Integrated Voltage Measurement... 15:52:40 Voltage Offset Correction: v_off_ini = -144.362 uV, v_off_fin = -146.455 uV 15:52:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.607 uVs 15:52:40 Integrated Voltage Measurement... 15:52:49 Voltage Offset Correction: v_off_ini = -144.360 uV, v_off_fin = -161.287 uV 15:52:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.269 uVs 15:52:49 Integrated Voltage Measurement... 15:52:58 Voltage Offset Correction: v_off_ini = -144.574 uV, v_off_fin = -158.742 uV 15:52:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.693 uVs 15:53:02 I1X Average and RMS of Measurements VT = -125.859 +- 2.024 uVs I1X = 25.172 +- 0.405 uTm 15:53:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:53:09 Integrated Voltage Measurement... 15:53:18 Voltage Offset Correction: v_off_ini = -145.362 uV, v_off_fin = -153.132 uV 15:53:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -276.148 uVs 15:53:18 Integrated Voltage Measurement... 15:53:27 Voltage Offset Correction: v_off_ini = -142.038 uV, v_off_fin = -123.598 uV 15:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 279.886 uVs 15:53:27 Integrated Voltage Measurement... 15:53:36 Voltage Offset Correction: v_off_ini = -142.653 uV, v_off_fin = -152.000 uV 15:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.126 uVs 15:53:36 Integrated Voltage Measurement... 15:53:45 Voltage Offset Correction: v_off_ini = -136.852 uV, v_off_fin = -131.229 uV 15:53:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 256.092 uVs 15:53:45 Integrated Voltage Measurement... 15:53:54 Voltage Offset Correction: v_off_ini = -139.767 uV, v_off_fin = -153.831 uV 15:53:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -258.441 uVs 15:53:54 Integrated Voltage Measurement... 15:54:03 Voltage Offset Correction: v_off_ini = -139.498 uV, v_off_fin = -122.271 uV 15:54:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 268.341 uVs 15:54:07 I1Y Average and RMS of Measurements VT = -264.505 +- 10.606 uVs I1Y = -52.896 +- 2.120 uTm 15:54:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:54:12 Integrated Voltage Measurement... 15:54:21 Voltage Offset Correction: v_off_ini = -142.027 uV, v_off_fin = -145.955 uV 15:54:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.164 uVs 15:54:22 Integrated Voltage Measurement... 15:54:31 Voltage Offset Correction: v_off_ini = -128.425 uV, v_off_fin = -135.936 uV 15:54:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.907 uVs 15:54:31 Integrated Voltage Measurement... 15:54:40 Voltage Offset Correction: v_off_ini = -144.471 uV, v_off_fin = -146.725 uV 15:54:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.407 uVs 15:54:40 Integrated Voltage Measurement... 15:54:49 Voltage Offset Correction: v_off_ini = -127.417 uV, v_off_fin = -120.893 uV 15:54:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.234 uVs 15:54:49 Integrated Voltage Measurement... 15:54:58 Voltage Offset Correction: v_off_ini = -138.088 uV, v_off_fin = -150.090 uV 15:54:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.684 uVs 15:54:58 Integrated Voltage Measurement... 15:55:07 Voltage Offset Correction: v_off_ini = -130.526 uV, v_off_fin = -124.425 uV 15:55:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.513 uVs 15:55:09 I2X Average and RMS of Measurements VT = -101.151 +- 2.104 uVs I2X = 9.306 +- 0.193 uTm^2 15:55:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:55:14 Integrated Voltage Measurement... 15:55:23 Voltage Offset Correction: v_off_ini = -139.293 uV, v_off_fin = -131.973 uV 15:55:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.434 uVs 15:55:23 Integrated Voltage Measurement... 15:55:32 Voltage Offset Correction: v_off_ini = -130.596 uV, v_off_fin = -131.226 uV 15:55:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.510 uVs 15:55:32 Integrated Voltage Measurement... 15:55:41 Voltage Offset Correction: v_off_ini = -134.121 uV, v_off_fin = -129.337 uV 15:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.103 uVs 15:55:41 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = -136.117 uV, v_off_fin = -136.430 uV 15:55:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.549 uVs 15:55:50 Integrated Voltage Measurement... 15:55:59 Voltage Offset Correction: v_off_ini = -136.145 uV, v_off_fin = -143.268 uV 15:55:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.902 uVs 15:55:59 Integrated Voltage Measurement... 15:56:08 Voltage Offset Correction: v_off_ini = -135.055 uV, v_off_fin = -137.612 uV 15:56:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.631 uVs 15:56:11 I2Y Average and RMS of Measurements VT = -298.021 +- 3.400 uVs I2Y = -27.418 +- 0.313 uTm^2 15:56:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:56:32 Integrated Voltage Measurement... 15:56:41 Voltage Offset Correction: v_off_ini = -137.796 uV, v_off_fin = -155.480 uV 15:56:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.019 uVs 15:56:41 Integrated Voltage Measurement... 15:56:50 Voltage Offset Correction: v_off_ini = -125.541 uV, v_off_fin = -129.901 uV 15:56:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.005 uVs 15:56:50 Integrated Voltage Measurement... 15:56:59 Voltage Offset Correction: v_off_ini = -152.722 uV, v_off_fin = -138.530 uV 15:56:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.679 uVs 15:56:59 Integrated Voltage Measurement... 15:57:08 Voltage Offset Correction: v_off_ini = -146.306 uV, v_off_fin = -135.980 uV 15:57:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 151.135 uVs 15:57:08 Integrated Voltage Measurement... 15:57:17 Voltage Offset Correction: v_off_ini = -135.945 uV, v_off_fin = -126.447 uV 15:57:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.101 uVs 15:57:17 Integrated Voltage Measurement... 15:57:26 Voltage Offset Correction: v_off_ini = -115.877 uV, v_off_fin = -108.550 uV 15:57:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 146.511 uVs 15:57:31 I1X Average and RMS of Measurements VT = -147.408 +- 1.066 uVs I1X = 29.484 +- 0.214 uTm 15:57:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:57:37 Integrated Voltage Measurement... 15:57:46 Voltage Offset Correction: v_off_ini = -139.725 uV, v_off_fin = -141.619 uV 15:57:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.006 uVs 15:57:46 Integrated Voltage Measurement... 15:57:55 Voltage Offset Correction: v_off_ini = -137.695 uV, v_off_fin = -114.185 uV 15:57:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.843 uVs 15:57:55 Integrated Voltage Measurement... 15:58:04 Voltage Offset Correction: v_off_ini = -125.963 uV, v_off_fin = -133.521 uV 15:58:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.622 uVs 15:58:04 Integrated Voltage Measurement... 15:58:13 Voltage Offset Correction: v_off_ini = -122.175 uV, v_off_fin = -112.758 uV 15:58:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.146 uVs 15:58:13 Integrated Voltage Measurement... 15:58:22 Voltage Offset Correction: v_off_ini = -121.252 uV, v_off_fin = -135.550 uV 15:58:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.236 uVs 15:58:22 Integrated Voltage Measurement... 15:58:31 Voltage Offset Correction: v_off_ini = -129.256 uV, v_off_fin = -115.842 uV 15:58:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.484 uVs 15:58:36 I1Y Average and RMS of Measurements VT = -221.556 +- 2.597 uVs I1Y = -44.311 +- 0.519 uTm 15:58:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:58:43 Integrated Voltage Measurement... 15:58:52 Voltage Offset Correction: v_off_ini = -128.489 uV, v_off_fin = -134.272 uV 15:58:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.552 uVs 15:58:52 Integrated Voltage Measurement... 15:59:01 Voltage Offset Correction: v_off_ini = -144.678 uV, v_off_fin = -133.468 uV 15:59:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.426 uVs 15:59:01 Integrated Voltage Measurement... 15:59:10 Voltage Offset Correction: v_off_ini = -135.848 uV, v_off_fin = -151.317 uV 15:59:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.220 uVs 15:59:10 Integrated Voltage Measurement... 15:59:19 Voltage Offset Correction: v_off_ini = -140.544 uV, v_off_fin = -120.555 uV 15:59:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.695 uVs 15:59:19 Integrated Voltage Measurement... 15:59:28 Voltage Offset Correction: v_off_ini = -132.057 uV, v_off_fin = -165.742 uV 15:59:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.114 uVs 15:59:28 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = -153.203 uV, v_off_fin = -130.071 uV 15:59:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.781 uVs 15:59:40 I2X Average and RMS of Measurements VT = -134.965 +- 4.013 uVs I2X = 12.417 +- 0.369 uTm^2 15:59:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:59:48 Integrated Voltage Measurement... 15:59:57 Voltage Offset Correction: v_off_ini = -149.475 uV, v_off_fin = -153.453 uV 15:59:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.229 uVs 15:59:57 Integrated Voltage Measurement... 16:00:06 Voltage Offset Correction: v_off_ini = -146.053 uV, v_off_fin = -143.696 uV 16:00:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 250.888 uVs 16:00:06 Integrated Voltage Measurement... 16:00:15 Voltage Offset Correction: v_off_ini = -136.630 uV, v_off_fin = -145.098 uV 16:00:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.478 uVs 16:00:15 Integrated Voltage Measurement... 16:00:24 Voltage Offset Correction: v_off_ini = -135.597 uV, v_off_fin = -129.832 uV 16:00:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.245 uVs 16:00:24 Integrated Voltage Measurement... 16:00:33 Voltage Offset Correction: v_off_ini = -131.188 uV, v_off_fin = -136.796 uV 16:00:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.798 uVs 16:00:33 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = -132.155 uV, v_off_fin = -125.638 uV 16:00:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.320 uVs 16:00:44 I2Y Average and RMS of Measurements VT = -252.993 +- 3.430 uVs I2Y = -23.276 +- 0.316 uTm^2 16:00:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:00:53 Integrated Voltage Measurement... 16:01:02 Voltage Offset Correction: v_off_ini = -138.921 uV, v_off_fin = -134.444 uV 16:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.274 uVs 16:01:02 Integrated Voltage Measurement... 16:01:11 Voltage Offset Correction: v_off_ini = -137.095 uV, v_off_fin = -133.314 uV 16:01:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.554 uVs 16:01:11 Integrated Voltage Measurement... 16:01:20 Voltage Offset Correction: v_off_ini = -140.133 uV, v_off_fin = -135.118 uV 16:01:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.686 uVs 16:01:20 Integrated Voltage Measurement... 16:01:29 Voltage Offset Correction: v_off_ini = -121.880 uV, v_off_fin = -126.992 uV 16:01:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.665 uVs 16:01:29 Integrated Voltage Measurement... 16:01:38 Voltage Offset Correction: v_off_ini = -121.302 uV, v_off_fin = -124.066 uV 16:01:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.752 uVs 16:01:38 Integrated Voltage Measurement... 16:01:47 Voltage Offset Correction: v_off_ini = -118.646 uV, v_off_fin = -117.991 uV 16:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.631 uVs 16:01:51 I1X Average and RMS of Measurements VT = -151.094 +- 6.448 uVs I1X = 30.219 +- 1.289 uTm 16:01:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:01:58 Integrated Voltage Measurement... 16:02:07 Voltage Offset Correction: v_off_ini = -139.853 uV, v_off_fin = -150.439 uV 16:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.084 uVs 16:02:07 Integrated Voltage Measurement... 16:02:16 Voltage Offset Correction: v_off_ini = -136.339 uV, v_off_fin = -124.543 uV 16:02:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.149 uVs 16:02:16 Integrated Voltage Measurement... 16:02:25 Voltage Offset Correction: v_off_ini = -117.936 uV, v_off_fin = -134.585 uV 16:02:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.288 uVs 16:02:25 Integrated Voltage Measurement... 16:02:34 Voltage Offset Correction: v_off_ini = -129.027 uV, v_off_fin = -115.785 uV 16:02:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.756 uVs 16:02:34 Integrated Voltage Measurement... 16:02:43 Voltage Offset Correction: v_off_ini = -123.248 uV, v_off_fin = -136.579 uV 16:02:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.748 uVs 16:02:43 Integrated Voltage Measurement... 16:02:52 Voltage Offset Correction: v_off_ini = -131.866 uV, v_off_fin = -134.728 uV 16:02:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.300 uVs 16:02:57 I1Y Average and RMS of Measurements VT = -250.554 +- 5.481 uVs I1Y = -50.112 +- 1.097 uTm 16:03:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = -141.970 uV, v_off_fin = -155.091 uV 16:03:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.576 uVs 16:03:13 Integrated Voltage Measurement... 16:03:22 Voltage Offset Correction: v_off_ini = -142.833 uV, v_off_fin = -131.315 uV 16:03:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.675 uVs 16:03:22 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = -147.954 uV, v_off_fin = -154.268 uV 16:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.054 uVs 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = -148.183 uV, v_off_fin = -143.231 uV 16:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.995 uVs 16:03:40 Integrated Voltage Measurement... 16:03:49 Voltage Offset Correction: v_off_ini = -152.737 uV, v_off_fin = -174.564 uV 16:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.142 uVs 16:03:49 Integrated Voltage Measurement... 16:03:58 Voltage Offset Correction: v_off_ini = -166.299 uV, v_off_fin = -142.338 uV 16:03:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.665 uVs 16:04:01 I2X Average and RMS of Measurements VT = -138.184 +- 11.678 uVs I2X = 12.713 +- 1.075 uTm^2 16:04:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:04:09 Integrated Voltage Measurement... 16:04:18 Voltage Offset Correction: v_off_ini = -150.076 uV, v_off_fin = -133.172 uV 16:04:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.418 uVs 16:04:18 Integrated Voltage Measurement... 16:04:27 Voltage Offset Correction: v_off_ini = -138.477 uV, v_off_fin = -148.962 uV 16:04:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.975 uVs 16:04:27 Integrated Voltage Measurement... 16:04:36 Voltage Offset Correction: v_off_ini = -161.362 uV, v_off_fin = -164.025 uV 16:04:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.603 uVs 16:04:36 Integrated Voltage Measurement... 16:04:45 Voltage Offset Correction: v_off_ini = -162.331 uV, v_off_fin = -154.689 uV 16:04:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.095 uVs 16:04:45 Integrated Voltage Measurement... 16:04:54 Voltage Offset Correction: v_off_ini = -162.883 uV, v_off_fin = -156.709 uV 16:04:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.057 uVs 16:04:54 Integrated Voltage Measurement... 16:05:03 Voltage Offset Correction: v_off_ini = -173.722 uV, v_off_fin = -165.240 uV 16:05:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.802 uVs 16:05:05 I2Y Average and RMS of Measurements VT = -278.825 +- 4.047 uVs I2Y = -25.652 +- 0.372 uTm^2 16:05:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:14 Integrated Voltage Measurement... 16:05:23 Voltage Offset Correction: v_off_ini = -154.476 uV, v_off_fin = -173.625 uV 16:05:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.459 uVs 16:05:23 Integrated Voltage Measurement... 16:05:32 Voltage Offset Correction: v_off_ini = -166.931 uV, v_off_fin = -150.978 uV 16:05:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.877 uVs 16:05:32 Integrated Voltage Measurement... 16:05:41 Voltage Offset Correction: v_off_ini = -153.143 uV, v_off_fin = -144.118 uV 16:05:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.078 uVs 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = -147.130 uV, v_off_fin = -146.688 uV 16:05:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.454 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = -148.398 uV, v_off_fin = -150.737 uV 16:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.126 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = -153.824 uV, v_off_fin = -149.722 uV 16:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.836 uVs 16:06:12 I1X Average and RMS of Measurements VT = -160.805 +- 4.191 uVs I1X = 32.161 +- 0.838 uTm 16:06:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:19 Integrated Voltage Measurement... 16:06:28 Voltage Offset Correction: v_off_ini = -139.623 uV, v_off_fin = -152.106 uV 16:06:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.234 uVs 16:06:28 Integrated Voltage Measurement... 16:06:37 Voltage Offset Correction: v_off_ini = -150.731 uV, v_off_fin = -135.210 uV 16:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.457 uVs 16:06:37 Integrated Voltage Measurement... 16:06:46 Voltage Offset Correction: v_off_ini = -157.263 uV, v_off_fin = -165.048 uV 16:06:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.489 uVs 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = -158.267 uV, v_off_fin = -147.989 uV 16:06:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.268 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = -135.893 uV, v_off_fin = -153.157 uV 16:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.780 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = -132.741 uV, v_off_fin = -129.624 uV 16:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.549 uVs 16:07:17 I1Y Average and RMS of Measurements VT = -255.629 +- 8.954 uVs I1Y = -51.126 +- 1.791 uTm 16:07:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:25 Integrated Voltage Measurement... 16:07:34 Voltage Offset Correction: v_off_ini = -125.636 uV, v_off_fin = -141.326 uV 16:07:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -162.739 uVs 16:07:34 Integrated Voltage Measurement... 16:07:43 Voltage Offset Correction: v_off_ini = -147.762 uV, v_off_fin = -134.366 uV 16:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.250 uVs 16:07:43 Integrated Voltage Measurement... 16:07:52 Voltage Offset Correction: v_off_ini = -146.761 uV, v_off_fin = -139.406 uV 16:07:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.199 uVs 16:07:52 Integrated Voltage Measurement... 16:08:01 Voltage Offset Correction: v_off_ini = -132.053 uV, v_off_fin = -123.354 uV 16:08:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.438 uVs 16:08:01 Integrated Voltage Measurement... 16:08:10 Voltage Offset Correction: v_off_ini = -136.300 uV, v_off_fin = -135.079 uV 16:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.546 uVs 16:08:10 Integrated Voltage Measurement... 16:08:19 Voltage Offset Correction: v_off_ini = -136.988 uV, v_off_fin = -126.680 uV 16:08:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.464 uVs 16:08:22 I2X Average and RMS of Measurements VT = -143.940 +- 7.824 uVs I2X = 13.243 +- 0.720 uTm^2 16:08:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:29 Integrated Voltage Measurement... 16:08:38 Voltage Offset Correction: v_off_ini = -125.502 uV, v_off_fin = -136.573 uV 16:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.074 uVs 16:08:39 Integrated Voltage Measurement... 16:08:48 Voltage Offset Correction: v_off_ini = -139.114 uV, v_off_fin = -121.440 uV 16:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.401 uVs 16:08:48 Integrated Voltage Measurement... 16:08:57 Voltage Offset Correction: v_off_ini = -131.334 uV, v_off_fin = -129.417 uV 16:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.218 uVs 16:08:57 Integrated Voltage Measurement... 16:09:06 Voltage Offset Correction: v_off_ini = -117.249 uV, v_off_fin = -125.480 uV 16:09:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.322 uVs 16:09:06 Integrated Voltage Measurement... 16:09:15 Voltage Offset Correction: v_off_ini = -115.838 uV, v_off_fin = -117.826 uV 16:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.109 uVs 16:09:15 Integrated Voltage Measurement... 16:09:24 Voltage Offset Correction: v_off_ini = -128.292 uV, v_off_fin = -126.887 uV 16:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.464 uVs 16:09:26 I2Y Average and RMS of Measurements VT = -298.931 +- 1.228 uVs I2Y = -27.502 +- 0.113 uTm^2 16:09:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:09:35 Integrated Voltage Measurement... 16:09:44 Voltage Offset Correction: v_off_ini = -114.838 uV, v_off_fin = -127.960 uV 16:09:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -165.476 uVs 16:09:44 Integrated Voltage Measurement... 16:09:53 Voltage Offset Correction: v_off_ini = -112.643 uV, v_off_fin = -102.051 uV 16:09:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.271 uVs 16:09:53 Integrated Voltage Measurement... 16:10:02 Voltage Offset Correction: v_off_ini = -122.422 uV, v_off_fin = -123.862 uV 16:10:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.222 uVs 16:10:02 Integrated Voltage Measurement... 16:10:11 Voltage Offset Correction: v_off_ini = -112.113 uV, v_off_fin = -109.459 uV 16:10:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.082 uVs 16:10:11 Integrated Voltage Measurement... 16:10:20 Voltage Offset Correction: v_off_ini = -122.590 uV, v_off_fin = -123.787 uV 16:10:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.456 uVs 16:10:20 Integrated Voltage Measurement... 16:10:29 Voltage Offset Correction: v_off_ini = -128.568 uV, v_off_fin = -128.662 uV 16:10:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.732 uVs 16:10:33 I1X Average and RMS of Measurements VT = -150.373 +- 3.040 uVs I1X = 30.076 +- 0.609 uTm 16:10:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:10:40 Integrated Voltage Measurement... 16:10:49 Voltage Offset Correction: v_off_ini = -135.890 uV, v_off_fin = -145.136 uV 16:10:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.577 uVs 16:10:49 Integrated Voltage Measurement... 16:10:58 Voltage Offset Correction: v_off_ini = -139.366 uV, v_off_fin = -120.521 uV 16:10:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.261 uVs 16:10:58 Integrated Voltage Measurement... 16:11:07 Voltage Offset Correction: v_off_ini = -120.909 uV, v_off_fin = -140.004 uV 16:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.916 uVs 16:11:07 Integrated Voltage Measurement... 16:11:16 Voltage Offset Correction: v_off_ini = -139.325 uV, v_off_fin = -118.820 uV 16:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.127 uVs 16:11:16 Integrated Voltage Measurement... 16:11:25 Voltage Offset Correction: v_off_ini = -138.889 uV, v_off_fin = -144.723 uV 16:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.087 uVs 16:11:25 Integrated Voltage Measurement... 16:11:34 Voltage Offset Correction: v_off_ini = -135.396 uV, v_off_fin = -126.126 uV 16:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.227 uVs 16:11:38 I1Y Average and RMS of Measurements VT = -277.366 +- 4.750 uVs I1Y = -55.473 +- 0.950 uTm 16:11:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:11:46 Integrated Voltage Measurement... 16:11:55 Voltage Offset Correction: v_off_ini = -144.506 uV, v_off_fin = -158.180 uV 16:11:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -157.551 uVs 16:11:55 Integrated Voltage Measurement... 16:12:04 Voltage Offset Correction: v_off_ini = -141.943 uV, v_off_fin = -133.243 uV 16:12:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 147.734 uVs 16:12:04 Integrated Voltage Measurement... 16:12:13 Voltage Offset Correction: v_off_ini = -133.053 uV, v_off_fin = -142.947 uV 16:12:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.137 uVs 16:12:13 Integrated Voltage Measurement... 16:12:22 Voltage Offset Correction: v_off_ini = -135.199 uV, v_off_fin = -117.021 uV 16:12:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.274 uVs 16:12:22 Integrated Voltage Measurement... 16:12:31 Voltage Offset Correction: v_off_ini = -123.505 uV, v_off_fin = -133.839 uV 16:12:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -150.145 uVs 16:12:31 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = -125.685 uV, v_off_fin = -125.435 uV 16:12:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.771 uVs 16:12:43 I2X Average and RMS of Measurements VT = -149.102 +- 2.667 uVs I2X = 13.718 +- 0.245 uTm^2 16:12:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:12:50 Integrated Voltage Measurement... 16:12:59 Voltage Offset Correction: v_off_ini = -129.206 uV, v_off_fin = -124.778 uV 16:12:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.381 uVs 16:13:00 Integrated Voltage Measurement... 16:13:08 Voltage Offset Correction: v_off_ini = -129.157 uV, v_off_fin = -119.721 uV 16:13:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.414 uVs 16:13:09 Integrated Voltage Measurement... 16:13:18 Voltage Offset Correction: v_off_ini = -125.967 uV, v_off_fin = -115.572 uV 16:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.655 uVs 16:13:18 Integrated Voltage Measurement... 16:13:27 Voltage Offset Correction: v_off_ini = -113.017 uV, v_off_fin = -127.768 uV 16:13:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.354 uVs 16:13:27 Integrated Voltage Measurement... 16:13:36 Voltage Offset Correction: v_off_ini = -135.740 uV, v_off_fin = -136.306 uV 16:13:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.088 uVs 16:13:36 Integrated Voltage Measurement... 16:13:45 Voltage Offset Correction: v_off_ini = -131.720 uV, v_off_fin = -137.086 uV 16:13:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.141 uVs 16:13:47 I2Y Average and RMS of Measurements VT = -319.506 +- 2.496 uVs I2Y = -29.395 +- 0.230 uTm^2 16:13:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:13:56 Integrated Voltage Measurement... 16:14:05 Voltage Offset Correction: v_off_ini = -138.129 uV, v_off_fin = -138.291 uV 16:14:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.826 uVs 16:14:05 Integrated Voltage Measurement... 16:14:14 Voltage Offset Correction: v_off_ini = -128.915 uV, v_off_fin = -120.048 uV 16:14:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.944 uVs 16:14:14 Integrated Voltage Measurement... 16:14:23 Voltage Offset Correction: v_off_ini = -119.432 uV, v_off_fin = -135.139 uV 16:14:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.720 uVs 16:14:23 Integrated Voltage Measurement... 16:14:32 Voltage Offset Correction: v_off_ini = -144.333 uV, v_off_fin = -133.736 uV 16:14:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.600 uVs 16:14:32 Integrated Voltage Measurement... 16:14:41 Voltage Offset Correction: v_off_ini = -142.125 uV, v_off_fin = -153.761 uV 16:14:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.099 uVs 16:14:41 Integrated Voltage Measurement... 16:14:50 Voltage Offset Correction: v_off_ini = -155.939 uV, v_off_fin = -148.952 uV 16:14:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 175.687 uVs 16:14:54 I1X Average and RMS of Measurements VT = -161.146 +- 5.159 uVs I1X = 32.230 +- 1.031 uTm 16:14:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:15:01 Integrated Voltage Measurement... 16:15:10 Voltage Offset Correction: v_off_ini = -140.507 uV, v_off_fin = -139.762 uV 16:15:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.618 uVs 16:15:10 Integrated Voltage Measurement... 16:15:19 Voltage Offset Correction: v_off_ini = -135.947 uV, v_off_fin = -116.364 uV 16:15:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.954 uVs 16:15:19 Integrated Voltage Measurement... 16:15:28 Voltage Offset Correction: v_off_ini = -136.934 uV, v_off_fin = -144.698 uV 16:15:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -302.342 uVs 16:15:28 Integrated Voltage Measurement... 16:15:37 Voltage Offset Correction: v_off_ini = -128.898 uV, v_off_fin = -111.918 uV 16:15:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.417 uVs 16:15:37 Integrated Voltage Measurement... 16:15:46 Voltage Offset Correction: v_off_ini = -126.169 uV, v_off_fin = -140.570 uV 16:15:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.880 uVs 16:15:46 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = -124.616 uV, v_off_fin = -110.708 uV 16:15:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 290.715 uVs 16:15:59 I1Y Average and RMS of Measurements VT = -291.654 +- 2.415 uVs I1Y = -58.331 +- 0.483 uTm 16:16:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:16:07 Integrated Voltage Measurement... 16:16:16 Voltage Offset Correction: v_off_ini = -130.055 uV, v_off_fin = -148.170 uV 16:16:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -151.512 uVs 16:16:16 Integrated Voltage Measurement... 16:16:25 Voltage Offset Correction: v_off_ini = -131.914 uV, v_off_fin = -121.534 uV 16:16:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.258 uVs 16:16:25 Integrated Voltage Measurement... 16:16:34 Voltage Offset Correction: v_off_ini = -127.808 uV, v_off_fin = -131.764 uV 16:16:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.463 uVs 16:16:34 Integrated Voltage Measurement... 16:16:43 Voltage Offset Correction: v_off_ini = -129.526 uV, v_off_fin = -121.012 uV 16:16:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.969 uVs 16:16:43 Integrated Voltage Measurement... 16:16:52 Voltage Offset Correction: v_off_ini = -132.157 uV, v_off_fin = -152.122 uV 16:16:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.264 uVs 16:16:52 Integrated Voltage Measurement... 16:17:01 Voltage Offset Correction: v_off_ini = -132.807 uV, v_off_fin = -128.367 uV 16:17:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.628 uVs 16:17:03 I2X Average and RMS of Measurements VT = -153.516 +- 5.476 uVs I2X = 14.123 +- 0.504 uTm^2 16:17:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:17:11 Integrated Voltage Measurement... 16:17:20 Voltage Offset Correction: v_off_ini = -151.601 uV, v_off_fin = -149.535 uV 16:17:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.183 uVs 16:17:20 Integrated Voltage Measurement... 16:17:29 Voltage Offset Correction: v_off_ini = -141.941 uV, v_off_fin = -141.982 uV 16:17:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.785 uVs 16:17:29 Integrated Voltage Measurement... 16:17:38 Voltage Offset Correction: v_off_ini = -144.232 uV, v_off_fin = -146.653 uV 16:17:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.692 uVs 16:17:38 Integrated Voltage Measurement... 16:17:47 Voltage Offset Correction: v_off_ini = -143.137 uV, v_off_fin = -133.695 uV 16:17:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.929 uVs 16:17:47 Integrated Voltage Measurement... 16:17:56 Voltage Offset Correction: v_off_ini = -134.284 uV, v_off_fin = -137.306 uV 16:17:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.945 uVs 16:17:56 Integrated Voltage Measurement... 16:18:05 Voltage Offset Correction: v_off_ini = -132.591 uV, v_off_fin = -136.928 uV 16:18:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.170 uVs 16:18:08 I2Y Average and RMS of Measurements VT = -331.117 +- 5.045 uVs I2Y = -30.463 +- 0.464 uTm^2 16:18:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:18:20 Integrated Voltage Measurement... 16:18:28 Voltage Offset Correction: v_off_ini = -107.967 uV, v_off_fin = -115.199 uV 16:18:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -188.398 uVs 16:18:29 Integrated Voltage Measurement... 16:18:37 Voltage Offset Correction: v_off_ini = -117.425 uV, v_off_fin = -123.757 uV 16:18:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 183.401 uVs 16:18:38 Integrated Voltage Measurement... 16:18:46 Voltage Offset Correction: v_off_ini = -120.599 uV, v_off_fin = -127.347 uV 16:18:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.824 uVs 16:18:47 Integrated Voltage Measurement... 16:18:55 Voltage Offset Correction: v_off_ini = -116.072 uV, v_off_fin = -114.467 uV 16:18:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 151.446 uVs 16:18:56 Integrated Voltage Measurement... 16:19:05 Voltage Offset Correction: v_off_ini = -117.327 uV, v_off_fin = -124.217 uV 16:19:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.825 uVs 16:19:05 Integrated Voltage Measurement... 16:19:14 Voltage Offset Correction: v_off_ini = -122.987 uV, v_off_fin = -119.773 uV 16:19:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.820 uVs 16:19:18 I1X Average and RMS of Measurements VT = -160.452 +- 18.016 uVs I1X = 32.093 +- 3.604 uTm 16:19:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:19:25 Integrated Voltage Measurement... 16:19:33 Voltage Offset Correction: v_off_ini = -116.707 uV, v_off_fin = -123.255 uV 16:19:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.117 uVs 16:19:34 Integrated Voltage Measurement... 16:19:42 Voltage Offset Correction: v_off_ini = -121.208 uV, v_off_fin = -116.086 uV 16:19:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.590 uVs 16:19:43 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = -126.797 uV, v_off_fin = -124.279 uV 16:19:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.567 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = -123.635 uV, v_off_fin = -109.862 uV 16:20:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.394 uVs 16:20:01 Integrated Voltage Measurement... 16:20:09 Voltage Offset Correction: v_off_ini = -118.118 uV, v_off_fin = -127.933 uV 16:20:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.775 uVs 16:20:10 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = -122.759 uV, v_off_fin = -114.909 uV 16:20:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.630 uVs 16:20:23 I1Y Average and RMS of Measurements VT = -260.345 +- 11.030 uVs I1Y = -52.070 +- 2.205 uTm 16:20:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:20:28 Integrated Voltage Measurement... 16:20:37 Voltage Offset Correction: v_off_ini = -124.856 uV, v_off_fin = -123.255 uV 16:20:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -150.420 uVs 16:20:37 Integrated Voltage Measurement... 16:20:46 Voltage Offset Correction: v_off_ini = -119.647 uV, v_off_fin = -108.992 uV 16:20:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.192 uVs 16:20:46 Integrated Voltage Measurement... 16:20:55 Voltage Offset Correction: v_off_ini = -105.048 uV, v_off_fin = -118.999 uV 16:20:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -155.757 uVs 16:20:55 Integrated Voltage Measurement... 16:21:04 Voltage Offset Correction: v_off_ini = -111.199 uV, v_off_fin = -109.569 uV 16:21:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.132 uVs 16:21:04 Integrated Voltage Measurement... 16:21:13 Voltage Offset Correction: v_off_ini = -121.063 uV, v_off_fin = -122.633 uV 16:21:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.988 uVs 16:21:13 Integrated Voltage Measurement... 16:21:22 Voltage Offset Correction: v_off_ini = -113.241 uV, v_off_fin = -110.292 uV 16:21:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.346 uVs 16:21:24 I2X Average and RMS of Measurements VT = -153.472 +- 0.964 uVs I2X = 14.119 +- 0.089 uTm^2 16:21:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:21:29 Integrated Voltage Measurement... 16:21:38 Voltage Offset Correction: v_off_ini = -108.844 uV, v_off_fin = -112.398 uV 16:21:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.597 uVs 16:21:38 Integrated Voltage Measurement... 16:21:47 Voltage Offset Correction: v_off_ini = -100.046 uV, v_off_fin = -107.971 uV 16:21:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.113 uVs 16:21:47 Integrated Voltage Measurement... 16:21:56 Voltage Offset Correction: v_off_ini = -109.797 uV, v_off_fin = -118.353 uV 16:21:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.416 uVs 16:21:56 Integrated Voltage Measurement... 16:22:05 Voltage Offset Correction: v_off_ini = -103.185 uV, v_off_fin = -110.909 uV 16:22:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.847 uVs 16:22:05 Integrated Voltage Measurement... 16:22:14 Voltage Offset Correction: v_off_ini = -95.040 uV, v_off_fin = -116.827 uV 16:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.130 uVs 16:22:14 Integrated Voltage Measurement... 16:22:23 Voltage Offset Correction: v_off_ini = -106.138 uV, v_off_fin = -113.771 uV 16:22:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.459 uVs 16:22:26 I2Y Average and RMS of Measurements VT = -285.927 +- 7.678 uVs I2Y = -26.305 +- 0.706 uTm^2 16:22:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:22:34 Integrated Voltage Measurement... 16:22:43 Voltage Offset Correction: v_off_ini = -104.002 uV, v_off_fin = -112.331 uV 16:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -172.746 uVs 16:22:43 Integrated Voltage Measurement... 16:22:52 Voltage Offset Correction: v_off_ini = -116.300 uV, v_off_fin = -118.793 uV 16:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.298 uVs 16:22:52 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = -132.326 uV, v_off_fin = -130.935 uV 16:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.773 uVs 16:23:01 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = -128.596 uV, v_off_fin = -120.394 uV 16:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.762 uVs 16:23:10 Integrated Voltage Measurement... 16:23:19 Voltage Offset Correction: v_off_ini = -120.930 uV, v_off_fin = -113.259 uV 16:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.231 uVs 16:23:19 Integrated Voltage Measurement... 16:23:28 Voltage Offset Correction: v_off_ini = -129.317 uV, v_off_fin = -112.180 uV 16:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.530 uVs 16:23:32 I1X Average and RMS of Measurements VT = -154.390 +- 5.313 uVs I1X = 30.878 +- 1.063 uTm 16:23:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:23:39 Integrated Voltage Measurement... 16:23:48 Voltage Offset Correction: v_off_ini = -108.032 uV, v_off_fin = -120.782 uV 16:23:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.357 uVs 16:23:48 Integrated Voltage Measurement... 16:23:57 Voltage Offset Correction: v_off_ini = -111.344 uV, v_off_fin = -107.391 uV 16:23:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.184 uVs 16:23:57 Integrated Voltage Measurement... 16:24:06 Voltage Offset Correction: v_off_ini = -115.604 uV, v_off_fin = -115.689 uV 16:24:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.390 uVs 16:24:06 Integrated Voltage Measurement... 16:24:15 Voltage Offset Correction: v_off_ini = -107.282 uV, v_off_fin = -95.169 uV 16:24:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.180 uVs 16:24:15 Integrated Voltage Measurement... 16:24:24 Voltage Offset Correction: v_off_ini = -104.216 uV, v_off_fin = -109.841 uV 16:24:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.736 uVs 16:24:24 Integrated Voltage Measurement... 16:24:33 Voltage Offset Correction: v_off_ini = -106.311 uV, v_off_fin = -89.969 uV 16:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.634 uVs 16:24:37 I1Y Average and RMS of Measurements VT = -253.413 +- 1.922 uVs I1Y = -50.683 +- 0.384 uTm 16:24:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:24:42 Integrated Voltage Measurement... 16:24:51 Voltage Offset Correction: v_off_ini = -107.260 uV, v_off_fin = -102.356 uV 16:24:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.255 uVs 16:24:51 Integrated Voltage Measurement... 16:25:00 Voltage Offset Correction: v_off_ini = -94.143 uV, v_off_fin = -93.554 uV 16:25:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 165.327 uVs 16:25:00 Integrated Voltage Measurement... 16:25:09 Voltage Offset Correction: v_off_ini = -93.777 uV, v_off_fin = -93.939 uV 16:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.983 uVs 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = -78.262 uV, v_off_fin = -78.039 uV 16:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.605 uVs 16:25:19 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = -88.464 uV, v_off_fin = -97.558 uV 16:25:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.320 uVs 16:25:28 Integrated Voltage Measurement... 16:25:37 Voltage Offset Correction: v_off_ini = -85.401 uV, v_off_fin = -71.793 uV 16:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.668 uVs 16:25:39 I2X Average and RMS of Measurements VT = -150.360 +- 5.443 uVs I2X = 13.833 +- 0.501 uTm^2 16:25:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:25:44 Integrated Voltage Measurement... 16:25:53 Voltage Offset Correction: v_off_ini = -83.686 uV, v_off_fin = -85.297 uV 16:25:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.034 uVs 16:25:53 Integrated Voltage Measurement... 16:26:02 Voltage Offset Correction: v_off_ini = -82.381 uV, v_off_fin = -73.980 uV 16:26:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.019 uVs 16:26:02 Integrated Voltage Measurement... 16:26:11 Voltage Offset Correction: v_off_ini = -70.088 uV, v_off_fin = -88.209 uV 16:26:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.071 uVs 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = -81.849 uV, v_off_fin = -90.798 uV 16:26:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.140 uVs 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = -91.424 uV, v_off_fin = -92.496 uV 16:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.377 uVs 16:26:29 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = -89.676 uV, v_off_fin = -92.356 uV 16:26:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.082 uVs 16:26:41 I2Y Average and RMS of Measurements VT = -285.787 +- 5.852 uVs I2Y = -26.292 +- 0.538 uTm^2 16:26:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:49 Integrated Voltage Measurement... 16:26:58 Voltage Offset Correction: v_off_ini = -72.976 uV, v_off_fin = -82.504 uV 16:26:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.842 uVs 16:26:58 Integrated Voltage Measurement... 16:27:07 Voltage Offset Correction: v_off_ini = -86.100 uV, v_off_fin = -83.528 uV 16:27:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.575 uVs 16:27:07 Integrated Voltage Measurement... 16:27:16 Voltage Offset Correction: v_off_ini = -96.951 uV, v_off_fin = -76.611 uV 16:27:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -139.953 uVs 16:27:16 Integrated Voltage Measurement... 16:27:25 Voltage Offset Correction: v_off_ini = -71.486 uV, v_off_fin = -62.274 uV 16:27:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.086 uVs 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = -65.962 uV, v_off_fin = -71.847 uV 16:27:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.430 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = -64.500 uV, v_off_fin = -70.455 uV 16:27:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.404 uVs 16:27:47 I1X Average and RMS of Measurements VT = -147.048 +- 3.984 uVs I1X = 29.411 +- 0.798 uTm 16:27:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:54 Integrated Voltage Measurement... 16:28:03 Voltage Offset Correction: v_off_ini = -82.734 uV, v_off_fin = -91.496 uV 16:28:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.008 uVs 16:28:03 Integrated Voltage Measurement... 16:28:12 Voltage Offset Correction: v_off_ini = -86.615 uV, v_off_fin = -76.061 uV 16:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.161 uVs 16:28:12 Integrated Voltage Measurement... 16:28:21 Voltage Offset Correction: v_off_ini = -79.666 uV, v_off_fin = -105.596 uV 16:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.995 uVs 16:28:21 Integrated Voltage Measurement... 16:28:30 Voltage Offset Correction: v_off_ini = -102.904 uV, v_off_fin = -73.309 uV 16:28:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.156 uVs 16:28:30 Integrated Voltage Measurement... 16:28:39 Voltage Offset Correction: v_off_ini = -97.356 uV, v_off_fin = -105.560 uV 16:28:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.413 uVs 16:28:39 Integrated Voltage Measurement... 16:28:48 Voltage Offset Correction: v_off_ini = -99.811 uV, v_off_fin = -81.043 uV 16:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.488 uVs 16:28:52 I1Y Average and RMS of Measurements VT = -250.370 +- 4.063 uVs I1Y = -50.074 +- 0.813 uTm 16:28:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:57 Integrated Voltage Measurement... 16:29:06 Voltage Offset Correction: v_off_ini = -90.412 uV, v_off_fin = -120.994 uV 16:29:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -169.284 uVs 16:29:06 Integrated Voltage Measurement... 16:29:15 Voltage Offset Correction: v_off_ini = -122.389 uV, v_off_fin = -101.620 uV 16:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.598 uVs 16:29:15 Integrated Voltage Measurement... 16:29:24 Voltage Offset Correction: v_off_ini = -105.145 uV, v_off_fin = -117.701 uV 16:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.413 uVs 16:29:24 Integrated Voltage Measurement... 16:29:33 Voltage Offset Correction: v_off_ini = -103.214 uV, v_off_fin = -101.369 uV 16:29:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.140 uVs 16:29:33 Integrated Voltage Measurement... 16:29:42 Voltage Offset Correction: v_off_ini = -92.723 uV, v_off_fin = -105.399 uV 16:29:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.854 uVs 16:29:42 Integrated Voltage Measurement... 16:29:51 Voltage Offset Correction: v_off_ini = -102.705 uV, v_off_fin = -92.077 uV 16:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.925 uVs 16:29:54 I2X Average and RMS of Measurements VT = -144.869 +- 7.008 uVs I2X = 13.328 +- 0.644 uTm^2 16:29:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = -103.406 uV, v_off_fin = -104.809 uV 16:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.014 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = -104.602 uV, v_off_fin = -102.545 uV 16:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.338 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = -92.793 uV, v_off_fin = -99.078 uV 16:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.189 uVs 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = -94.714 uV, v_off_fin = -93.309 uV 16:30:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.235 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = -110.935 uV, v_off_fin = -96.701 uV 16:30:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.580 uVs 16:30:44 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = -105.923 uV, v_off_fin = -103.972 uV 16:30:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.353 uVs 16:30:55 I2Y Average and RMS of Measurements VT = -293.618 +- 4.262 uVs I2Y = -27.013 +- 0.392 uTm^2 16:30:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:31:04 Integrated Voltage Measurement... 16:31:13 Voltage Offset Correction: v_off_ini = -97.096 uV, v_off_fin = -114.001 uV 16:31:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.078 uVs 16:31:13 Integrated Voltage Measurement... 16:31:22 Voltage Offset Correction: v_off_ini = -95.202 uV, v_off_fin = -79.575 uV 16:31:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.201 uVs 16:31:22 Integrated Voltage Measurement... 16:31:31 Voltage Offset Correction: v_off_ini = -87.572 uV, v_off_fin = -82.331 uV 16:31:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.519 uVs 16:31:31 Integrated Voltage Measurement... 16:31:40 Voltage Offset Correction: v_off_ini = -96.056 uV, v_off_fin = -87.353 uV 16:31:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.222 uVs 16:31:40 Integrated Voltage Measurement... 16:31:49 Voltage Offset Correction: v_off_ini = -91.109 uV, v_off_fin = -84.543 uV 16:31:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.779 uVs 16:31:49 Integrated Voltage Measurement... 16:31:58 Voltage Offset Correction: v_off_ini = -96.174 uV, v_off_fin = -95.294 uV 16:31:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.276 uVs 16:32:02 I1X Average and RMS of Measurements VT = -141.679 +- 3.862 uVs I1X = 28.336 +- 0.773 uTm 16:32:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:32:09 Integrated Voltage Measurement... 16:32:18 Voltage Offset Correction: v_off_ini = -100.419 uV, v_off_fin = -108.825 uV 16:32:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.962 uVs 16:32:18 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = -91.442 uV, v_off_fin = -85.922 uV 16:32:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.439 uVs 16:32:27 Integrated Voltage Measurement... 16:32:36 Voltage Offset Correction: v_off_ini = -88.174 uV, v_off_fin = -111.144 uV 16:32:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -242.605 uVs 16:32:36 Integrated Voltage Measurement... 16:32:45 Voltage Offset Correction: v_off_ini = -95.318 uV, v_off_fin = -59.032 uV 16:32:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 255.500 uVs 16:32:45 Integrated Voltage Measurement... 16:32:54 Voltage Offset Correction: v_off_ini = -84.480 uV, v_off_fin = -88.571 uV 16:32:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.947 uVs 16:32:54 Integrated Voltage Measurement... 16:33:03 Voltage Offset Correction: v_off_ini = -90.399 uV, v_off_fin = -72.855 uV 16:33:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.337 uVs 16:33:07 I1Y Average and RMS of Measurements VT = -252.298 +- 2.306 uVs I1Y = -50.458 +- 0.464 uTm 16:33:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:33:12 Integrated Voltage Measurement... 16:33:21 Voltage Offset Correction: v_off_ini = -98.806 uV, v_off_fin = -92.358 uV 16:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.015 uVs 16:33:21 Integrated Voltage Measurement... 16:33:30 Voltage Offset Correction: v_off_ini = -93.238 uV, v_off_fin = -63.314 uV 16:33:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.254 uVs 16:33:30 Integrated Voltage Measurement... 16:33:39 Voltage Offset Correction: v_off_ini = -95.725 uV, v_off_fin = -107.753 uV 16:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.211 uVs 16:33:39 Integrated Voltage Measurement... 16:33:48 Voltage Offset Correction: v_off_ini = -97.526 uV, v_off_fin = -83.518 uV 16:33:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.605 uVs 16:33:48 Integrated Voltage Measurement... 16:33:57 Voltage Offset Correction: v_off_ini = -91.031 uV, v_off_fin = -97.085 uV 16:33:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.780 uVs 16:33:57 Integrated Voltage Measurement... 16:34:06 Voltage Offset Correction: v_off_ini = -100.442 uV, v_off_fin = -83.157 uV 16:34:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.621 uVs 16:34:09 I2X Average and RMS of Measurements VT = -131.248 +- 11.394 uVs I2X = 12.075 +- 1.048 uTm^2 16:34:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:34:14 Integrated Voltage Measurement... 16:34:23 Voltage Offset Correction: v_off_ini = -102.206 uV, v_off_fin = -97.195 uV 16:34:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.929 uVs 16:34:23 Integrated Voltage Measurement... 16:34:32 Voltage Offset Correction: v_off_ini = -100.961 uV, v_off_fin = -100.675 uV 16:34:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 292.933 uVs 16:34:32 Integrated Voltage Measurement... 16:34:41 Voltage Offset Correction: v_off_ini = -94.010 uV, v_off_fin = -100.320 uV 16:34:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.298 uVs 16:34:41 Integrated Voltage Measurement... 16:34:50 Voltage Offset Correction: v_off_ini = -93.808 uV, v_off_fin = -100.737 uV 16:34:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.725 uVs 16:34:50 Integrated Voltage Measurement... 16:34:59 Voltage Offset Correction: v_off_ini = -95.894 uV, v_off_fin = -100.629 uV 16:34:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.337 uVs 16:34:59 Integrated Voltage Measurement... 16:35:08 Voltage Offset Correction: v_off_ini = -105.801 uV, v_off_fin = -100.275 uV 16:35:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.548 uVs 16:35:10 I2Y Average and RMS of Measurements VT = -292.128 +- 7.737 uVs I2Y = -26.876 +- 0.712 uTm^2 16:35:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:35:19 Integrated Voltage Measurement... 16:35:28 Voltage Offset Correction: v_off_ini = -92.672 uV, v_off_fin = -86.607 uV 16:35:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.202 uVs 16:35:28 Integrated Voltage Measurement... 16:35:37 Voltage Offset Correction: v_off_ini = -94.063 uV, v_off_fin = -95.824 uV 16:35:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.678 uVs 16:35:37 Integrated Voltage Measurement... 16:35:46 Voltage Offset Correction: v_off_ini = -107.946 uV, v_off_fin = -97.750 uV 16:35:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -115.178 uVs 16:35:46 Integrated Voltage Measurement... 16:35:55 Voltage Offset Correction: v_off_ini = -93.877 uV, v_off_fin = -91.659 uV 16:35:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.192 uVs 16:35:55 Integrated Voltage Measurement... 16:36:04 Voltage Offset Correction: v_off_ini = -96.453 uV, v_off_fin = -101.999 uV 16:36:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.389 uVs 16:36:04 Integrated Voltage Measurement... 16:36:13 Voltage Offset Correction: v_off_ini = -95.835 uV, v_off_fin = -92.762 uV 16:36:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.329 uVs 16:36:17 I1X Average and RMS of Measurements VT = -126.495 +- 6.146 uVs I1X = 25.301 +- 1.229 uTm 16:36:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:36:24 Integrated Voltage Measurement... 16:36:33 Voltage Offset Correction: v_off_ini = -98.585 uV, v_off_fin = -100.345 uV 16:36:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -252.858 uVs 16:36:33 Integrated Voltage Measurement... 16:36:42 Voltage Offset Correction: v_off_ini = -91.555 uV, v_off_fin = -81.460 uV 16:36:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.348 uVs 16:36:42 Integrated Voltage Measurement... 16:36:51 Voltage Offset Correction: v_off_ini = -92.138 uV, v_off_fin = -94.217 uV 16:36:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -261.687 uVs 16:36:51 Integrated Voltage Measurement... 16:37:00 Voltage Offset Correction: v_off_ini = -94.027 uV, v_off_fin = -82.067 uV 16:37:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 278.179 uVs 16:37:00 Integrated Voltage Measurement... 16:37:09 Voltage Offset Correction: v_off_ini = -77.874 uV, v_off_fin = -91.756 uV 16:37:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -283.820 uVs 16:37:09 Integrated Voltage Measurement... 16:37:18 Voltage Offset Correction: v_off_ini = -101.286 uV, v_off_fin = -76.563 uV 16:37:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.531 uVs 16:37:22 I1Y Average and RMS of Measurements VT = -266.737 +- 3.996 uVs I1Y = -53.345 +- 0.795 uTm 16:37:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:37:27 Integrated Voltage Measurement... 16:37:36 Voltage Offset Correction: v_off_ini = -100.962 uV, v_off_fin = -99.907 uV 16:37:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.804 uVs 16:37:36 Integrated Voltage Measurement... 16:37:45 Voltage Offset Correction: v_off_ini = -99.870 uV, v_off_fin = -95.939 uV 16:37:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.478 uVs 16:37:45 Integrated Voltage Measurement... 16:37:54 Voltage Offset Correction: v_off_ini = -100.170 uV, v_off_fin = -113.605 uV 16:37:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.755 uVs 16:37:54 Integrated Voltage Measurement... 16:38:03 Voltage Offset Correction: v_off_ini = -109.785 uV, v_off_fin = -93.508 uV 16:38:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.079 uVs 16:38:03 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = -108.276 uV, v_off_fin = -114.091 uV 16:38:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.416 uVs 16:38:12 Integrated Voltage Measurement... 16:38:21 Voltage Offset Correction: v_off_ini = -105.813 uV, v_off_fin = -95.471 uV 16:38:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.680 uVs 16:38:24 I2X Average and RMS of Measurements VT = -109.869 +- 0.939 uVs I2X = 10.108 +- 0.086 uTm^2 16:38:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:38:29 Integrated Voltage Measurement... 16:38:38 Voltage Offset Correction: v_off_ini = -91.613 uV, v_off_fin = -86.798 uV 16:38:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.255 uVs 16:38:38 Integrated Voltage Measurement... 16:38:47 Voltage Offset Correction: v_off_ini = -84.401 uV, v_off_fin = -97.290 uV 16:38:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.670 uVs 16:38:47 Integrated Voltage Measurement... 16:38:56 Voltage Offset Correction: v_off_ini = -87.492 uV, v_off_fin = -82.121 uV 16:38:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.668 uVs 16:38:56 Integrated Voltage Measurement... 16:39:05 Voltage Offset Correction: v_off_ini = -97.936 uV, v_off_fin = -91.250 uV 16:39:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.052 uVs 16:39:05 Integrated Voltage Measurement... 16:39:14 Voltage Offset Correction: v_off_ini = -99.769 uV, v_off_fin = -108.206 uV 16:39:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.615 uVs 16:39:14 Integrated Voltage Measurement... 16:39:23 Voltage Offset Correction: v_off_ini = -113.864 uV, v_off_fin = -103.566 uV 16:39:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.958 uVs 16:39:26 I2Y Average and RMS of Measurements VT = -298.370 +- 9.285 uVs I2Y = -27.450 +- 0.854 uTm^2 16:39:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:40:01 Integrated Voltage Measurement... 16:40:10 Voltage Offset Correction: v_off_ini = -101.480 uV, v_off_fin = -112.861 uV 16:40:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.571 uVs 16:40:10 Integrated Voltage Measurement... 16:40:19 Voltage Offset Correction: v_off_ini = -107.635 uV, v_off_fin = -112.436 uV 16:40:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.604 uVs 16:40:19 Integrated Voltage Measurement... 16:40:28 Voltage Offset Correction: v_off_ini = -118.529 uV, v_off_fin = -117.349 uV 16:40:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.827 uVs 16:40:28 Integrated Voltage Measurement... 16:40:37 Voltage Offset Correction: v_off_ini = -116.814 uV, v_off_fin = -113.311 uV 16:40:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 118.149 uVs 16:40:37 Integrated Voltage Measurement... 16:40:46 Voltage Offset Correction: v_off_ini = -104.480 uV, v_off_fin = -114.209 uV 16:40:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.191 uVs 16:40:46 Integrated Voltage Measurement... 16:40:55 Voltage Offset Correction: v_off_ini = -105.243 uV, v_off_fin = -89.531 uV 16:40:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.270 uVs 16:40:59 I1X Average and RMS of Measurements VT = -110.435 +- 0.759 uVs I1X = 22.088 +- 0.153 uTm 16:41:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:41:06 Integrated Voltage Measurement... 16:41:15 Voltage Offset Correction: v_off_ini = -109.728 uV, v_off_fin = -122.542 uV 16:41:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.399 uVs 16:41:15 Integrated Voltage Measurement... 16:41:24 Voltage Offset Correction: v_off_ini = -119.523 uV, v_off_fin = -101.103 uV 16:41:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.739 uVs 16:41:24 Integrated Voltage Measurement... 16:41:33 Voltage Offset Correction: v_off_ini = -95.677 uV, v_off_fin = -121.133 uV 16:41:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -240.619 uVs 16:41:33 Integrated Voltage Measurement... 16:41:42 Voltage Offset Correction: v_off_ini = -109.117 uV, v_off_fin = -89.265 uV 16:41:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.667 uVs 16:41:42 Integrated Voltage Measurement... 16:41:51 Voltage Offset Correction: v_off_ini = -95.367 uV, v_off_fin = -113.926 uV 16:41:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.305 uVs 16:41:51 Integrated Voltage Measurement... 16:42:00 Voltage Offset Correction: v_off_ini = -99.675 uV, v_off_fin = -78.635 uV 16:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.142 uVs 16:42:04 I1Y Average and RMS of Measurements VT = -227.812 +- 4.665 uVs I1Y = -45.563 +- 0.934 uTm 16:42:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:42:12 Integrated Voltage Measurement... 16:42:21 Voltage Offset Correction: v_off_ini = -119.614 uV, v_off_fin = -116.550 uV 16:42:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.543 uVs 16:42:21 Integrated Voltage Measurement... 16:42:30 Voltage Offset Correction: v_off_ini = -98.048 uV, v_off_fin = -86.597 uV 16:42:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.011 uVs 16:42:30 Integrated Voltage Measurement... 16:42:39 Voltage Offset Correction: v_off_ini = -88.139 uV, v_off_fin = -101.560 uV 16:42:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.096 uVs 16:42:39 Integrated Voltage Measurement... 16:42:48 Voltage Offset Correction: v_off_ini = -83.224 uV, v_off_fin = -74.498 uV 16:42:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.431 uVs 16:42:48 Integrated Voltage Measurement... 16:42:57 Voltage Offset Correction: v_off_ini = -74.699 uV, v_off_fin = -101.244 uV 16:42:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.113 uVs 16:42:57 Integrated Voltage Measurement... 16:43:06 Voltage Offset Correction: v_off_ini = -94.936 uV, v_off_fin = -88.081 uV 16:43:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.838 uVs 16:43:08 I2X Average and RMS of Measurements VT = -99.006 +- 2.669 uVs I2X = 9.109 +- 0.246 uTm^2 16:43:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:43:16 Integrated Voltage Measurement... 16:43:25 Voltage Offset Correction: v_off_ini = -98.226 uV, v_off_fin = -110.907 uV 16:43:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.229 uVs 16:43:25 Integrated Voltage Measurement... 16:43:34 Voltage Offset Correction: v_off_ini = -109.584 uV, v_off_fin = -103.838 uV 16:43:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.526 uVs 16:43:34 Integrated Voltage Measurement... 16:43:43 Voltage Offset Correction: v_off_ini = -107.204 uV, v_off_fin = -102.987 uV 16:43:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.760 uVs 16:43:43 Integrated Voltage Measurement... 16:43:52 Voltage Offset Correction: v_off_ini = -107.766 uV, v_off_fin = -109.549 uV 16:43:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.848 uVs 16:43:52 Integrated Voltage Measurement... 16:44:01 Voltage Offset Correction: v_off_ini = -101.825 uV, v_off_fin = -107.234 uV 16:44:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.893 uVs 16:44:01 Integrated Voltage Measurement... 16:44:10 Voltage Offset Correction: v_off_ini = -105.874 uV, v_off_fin = -95.744 uV 16:44:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.063 uVs 16:44:13 I2Y Average and RMS of Measurements VT = -248.220 +- 4.246 uVs I2Y = -22.836 +- 0.391 uTm^2 16:44:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:44:22 Integrated Voltage Measurement... 16:44:30 Voltage Offset Correction: v_off_ini = -97.700 uV, v_off_fin = -101.981 uV 16:44:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -120.162 uVs 16:44:31 Integrated Voltage Measurement... 16:44:39 Voltage Offset Correction: v_off_ini = -98.497 uV, v_off_fin = -83.759 uV 16:44:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 122.043 uVs 16:44:40 Integrated Voltage Measurement... 16:44:49 Voltage Offset Correction: v_off_ini = -88.611 uV, v_off_fin = -98.391 uV 16:44:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.387 uVs 16:44:49 Integrated Voltage Measurement... 16:44:58 Voltage Offset Correction: v_off_ini = -94.889 uV, v_off_fin = -90.337 uV 16:44:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.577 uVs 16:44:58 Integrated Voltage Measurement... 16:45:07 Voltage Offset Correction: v_off_ini = -92.233 uV, v_off_fin = -97.329 uV 16:45:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.343 uVs 16:45:07 Integrated Voltage Measurement... 16:45:16 Voltage Offset Correction: v_off_ini = -96.219 uV, v_off_fin = -107.853 uV 16:45:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.375 uVs 16:45:20 I1X Average and RMS of Measurements VT = -118.481 +- 3.536 uVs I1X = 23.697 +- 0.708 uTm 16:45:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:45:27 Integrated Voltage Measurement... 16:45:35 Voltage Offset Correction: v_off_ini = -102.511 uV, v_off_fin = -100.201 uV 16:45:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.252 uVs 16:45:36 Integrated Voltage Measurement... 16:45:44 Voltage Offset Correction: v_off_ini = -92.002 uV, v_off_fin = -81.015 uV 16:45:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.695 uVs 16:45:45 Integrated Voltage Measurement... 16:45:53 Voltage Offset Correction: v_off_ini = -85.364 uV, v_off_fin = -76.916 uV 16:45:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.618 uVs 16:45:53 Integrated Voltage Measurement... 16:46:02 Voltage Offset Correction: v_off_ini = -67.712 uV, v_off_fin = -65.723 uV 16:46:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.880 uVs 16:46:02 Integrated Voltage Measurement... 16:46:11 Voltage Offset Correction: v_off_ini = -75.360 uV, v_off_fin = -91.034 uV 16:46:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.236 uVs 16:46:11 Integrated Voltage Measurement... 16:46:20 Voltage Offset Correction: v_off_ini = -96.926 uV, v_off_fin = -79.125 uV 16:46:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.560 uVs 16:46:25 I1Y Average and RMS of Measurements VT = -248.207 +- 1.120 uVs I1Y = -49.641 +- 0.224 uTm 16:46:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:46:32 Integrated Voltage Measurement... 16:46:41 Voltage Offset Correction: v_off_ini = -81.900 uV, v_off_fin = -86.110 uV 16:46:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -116.941 uVs 16:46:41 Integrated Voltage Measurement... 16:46:50 Voltage Offset Correction: v_off_ini = -94.091 uV, v_off_fin = -83.855 uV 16:46:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.099 uVs 16:46:50 Integrated Voltage Measurement... 16:46:59 Voltage Offset Correction: v_off_ini = -92.469 uV, v_off_fin = -106.452 uV 16:46:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.408 uVs 16:46:59 Integrated Voltage Measurement... 16:47:08 Voltage Offset Correction: v_off_ini = -94.648 uV, v_off_fin = -91.506 uV 16:47:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.862 uVs 16:47:08 Integrated Voltage Measurement... 16:47:17 Voltage Offset Correction: v_off_ini = -99.016 uV, v_off_fin = -94.737 uV 16:47:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.737 uVs 16:47:18 Integrated Voltage Measurement... 16:47:26 Voltage Offset Correction: v_off_ini = -82.066 uV, v_off_fin = -82.661 uV 16:47:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.774 uVs 16:47:29 I2X Average and RMS of Measurements VT = -113.637 +- 9.646 uVs I2X = 10.454 +- 0.888 uTm^2 16:47:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:47:37 Integrated Voltage Measurement... 16:47:46 Voltage Offset Correction: v_off_ini = -94.121 uV, v_off_fin = -88.334 uV 16:47:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.817 uVs 16:47:46 Integrated Voltage Measurement... 16:47:55 Voltage Offset Correction: v_off_ini = -87.465 uV, v_off_fin = -88.419 uV 16:47:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.061 uVs 16:47:55 Integrated Voltage Measurement... 16:48:04 Voltage Offset Correction: v_off_ini = -85.155 uV, v_off_fin = -84.874 uV 16:48:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.865 uVs 16:48:04 Integrated Voltage Measurement... 16:48:13 Voltage Offset Correction: v_off_ini = -89.723 uV, v_off_fin = -85.908 uV 16:48:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.870 uVs 16:48:13 Integrated Voltage Measurement... 16:48:22 Voltage Offset Correction: v_off_ini = -93.734 uV, v_off_fin = -98.522 uV 16:48:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.147 uVs 16:48:22 Integrated Voltage Measurement... 16:48:31 Voltage Offset Correction: v_off_ini = -96.637 uV, v_off_fin = -83.186 uV 16:48:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.759 uVs 16:48:33 I2Y Average and RMS of Measurements VT = -255.420 +- 1.260 uVs I2Y = -23.499 +- 0.116 uTm^2 16:48:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:42 Integrated Voltage Measurement... 16:48:51 Voltage Offset Correction: v_off_ini = -93.262 uV, v_off_fin = -97.581 uV 16:48:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.366 uVs 16:48:51 Integrated Voltage Measurement... 16:49:00 Voltage Offset Correction: v_off_ini = -89.316 uV, v_off_fin = -84.821 uV 16:49:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.692 uVs 16:49:00 Integrated Voltage Measurement... 16:49:09 Voltage Offset Correction: v_off_ini = -85.604 uV, v_off_fin = -87.273 uV 16:49:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.920 uVs 16:49:09 Integrated Voltage Measurement... 16:49:18 Voltage Offset Correction: v_off_ini = -89.531 uV, v_off_fin = -77.072 uV 16:49:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.843 uVs 16:49:18 Integrated Voltage Measurement... 16:49:27 Voltage Offset Correction: v_off_ini = -73.085 uV, v_off_fin = -80.769 uV 16:49:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.058 uVs 16:49:27 Integrated Voltage Measurement... 16:49:36 Voltage Offset Correction: v_off_ini = -69.561 uV, v_off_fin = -76.173 uV 16:49:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.309 uVs 16:49:40 I1X Average and RMS of Measurements VT = -106.865 +- 6.379 uVs I1X = 21.373 +- 1.276 uTm 16:49:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:47 Integrated Voltage Measurement... 16:49:56 Voltage Offset Correction: v_off_ini = -74.534 uV, v_off_fin = -90.745 uV 16:49:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.661 uVs 16:49:56 Integrated Voltage Measurement... 16:50:05 Voltage Offset Correction: v_off_ini = -67.325 uV, v_off_fin = -60.835 uV 16:50:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.640 uVs 16:50:05 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = -77.949 uV, v_off_fin = -88.024 uV 16:50:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.657 uVs 16:50:14 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = -80.369 uV, v_off_fin = -62.067 uV 16:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.079 uVs 16:50:23 Integrated Voltage Measurement... 16:50:32 Voltage Offset Correction: v_off_ini = -81.941 uV, v_off_fin = -88.480 uV 16:50:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.398 uVs 16:50:32 Integrated Voltage Measurement... 16:50:41 Voltage Offset Correction: v_off_ini = -79.836 uV, v_off_fin = -71.251 uV 16:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.871 uVs 16:50:45 I1Y Average and RMS of Measurements VT = -240.884 +- 6.144 uVs I1Y = -48.177 +- 1.229 uTm 16:50:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:53 Integrated Voltage Measurement... 16:51:02 Voltage Offset Correction: v_off_ini = -85.353 uV, v_off_fin = -94.603 uV 16:51:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -98.881 uVs 16:51:02 Integrated Voltage Measurement... 16:51:11 Voltage Offset Correction: v_off_ini = -75.541 uV, v_off_fin = -66.912 uV 16:51:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.667 uVs 16:51:11 Integrated Voltage Measurement... 16:51:20 Voltage Offset Correction: v_off_ini = -77.405 uV, v_off_fin = -91.334 uV 16:51:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.646 uVs 16:51:20 Integrated Voltage Measurement... 16:51:29 Voltage Offset Correction: v_off_ini = -77.607 uV, v_off_fin = -71.275 uV 16:51:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.013 uVs 16:51:29 Integrated Voltage Measurement... 16:51:38 Voltage Offset Correction: v_off_ini = -81.900 uV, v_off_fin = -81.946 uV 16:51:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.039 uVs 16:51:38 Integrated Voltage Measurement... 16:51:47 Voltage Offset Correction: v_off_ini = -78.182 uV, v_off_fin = -72.858 uV 16:51:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.566 uVs 16:51:50 I2X Average and RMS of Measurements VT = -108.635 +- 1.642 uVs I2X = 9.994 +- 0.151 uTm^2 16:51:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:57 Integrated Voltage Measurement... 16:52:06 Voltage Offset Correction: v_off_ini = -86.626 uV, v_off_fin = -78.735 uV 16:52:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.961 uVs 16:52:06 Integrated Voltage Measurement... 16:52:15 Voltage Offset Correction: v_off_ini = -80.052 uV, v_off_fin = -78.283 uV 16:52:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.557 uVs 16:52:15 Integrated Voltage Measurement... 16:52:24 Voltage Offset Correction: v_off_ini = -75.867 uV, v_off_fin = -71.828 uV 16:52:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.603 uVs 16:52:24 Integrated Voltage Measurement... 16:52:33 Voltage Offset Correction: v_off_ini = -86.111 uV, v_off_fin = -77.552 uV 16:52:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.929 uVs 16:52:33 Integrated Voltage Measurement... 16:52:42 Voltage Offset Correction: v_off_ini = -76.564 uV, v_off_fin = -65.607 uV 16:52:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.315 uVs 16:52:42 Integrated Voltage Measurement... 16:52:51 Voltage Offset Correction: v_off_ini = -64.631 uV, v_off_fin = -70.032 uV 16:52:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.019 uVs 16:52:54 I2Y Average and RMS of Measurements VT = -249.731 +- 5.177 uVs I2Y = -22.975 +- 0.476 uTm^2 16:52:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:53:03 Integrated Voltage Measurement... 16:53:12 Voltage Offset Correction: v_off_ini = -66.416 uV, v_off_fin = -72.362 uV 16:53:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.773 uVs 16:53:12 Integrated Voltage Measurement... 16:53:21 Voltage Offset Correction: v_off_ini = -70.200 uV, v_off_fin = -61.789 uV 16:53:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.639 uVs 16:53:21 Integrated Voltage Measurement... 16:53:30 Voltage Offset Correction: v_off_ini = -54.645 uV, v_off_fin = -61.730 uV 16:53:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.066 uVs 16:53:30 Integrated Voltage Measurement... 16:53:39 Voltage Offset Correction: v_off_ini = -60.253 uV, v_off_fin = -50.683 uV 16:53:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.506 uVs 16:53:39 Integrated Voltage Measurement... 16:53:48 Voltage Offset Correction: v_off_ini = -56.680 uV, v_off_fin = -58.239 uV 16:53:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.148 uVs 16:53:48 Integrated Voltage Measurement... 16:53:57 Voltage Offset Correction: v_off_ini = -63.477 uV, v_off_fin = -47.957 uV 16:53:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.300 uVs 16:54:01 I1X Average and RMS of Measurements VT = -113.905 +- 2.256 uVs I1X = 22.782 +- 0.452 uTm 16:54:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:54:08 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = -66.885 uV, v_off_fin = -74.092 uV 16:54:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -258.864 uVs 16:54:17 Integrated Voltage Measurement... 16:54:26 Voltage Offset Correction: v_off_ini = -77.294 uV, v_off_fin = -51.183 uV 16:54:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.406 uVs 16:54:26 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = -64.001 uV, v_off_fin = -73.412 uV 16:54:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.167 uVs 16:54:35 Integrated Voltage Measurement... 16:54:44 Voltage Offset Correction: v_off_ini = -55.656 uV, v_off_fin = -35.709 uV 16:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.292 uVs 16:54:44 Integrated Voltage Measurement... 16:54:53 Voltage Offset Correction: v_off_ini = -41.301 uV, v_off_fin = -53.653 uV 16:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.344 uVs 16:54:53 Integrated Voltage Measurement... 16:55:02 Voltage Offset Correction: v_off_ini = -32.896 uV, v_off_fin = -43.755 uV 16:55:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.692 uVs 16:55:06 I1Y Average and RMS of Measurements VT = -258.461 +- 2.404 uVs I1Y = -51.693 +- 0.480 uTm 16:55:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:55:14 Integrated Voltage Measurement... 16:55:23 Voltage Offset Correction: v_off_ini = -70.473 uV, v_off_fin = -73.720 uV 16:55:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.481 uVs 16:55:23 Integrated Voltage Measurement... 16:55:32 Voltage Offset Correction: v_off_ini = -63.657 uV, v_off_fin = -56.656 uV 16:55:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.924 uVs 16:55:32 Integrated Voltage Measurement... 16:55:41 Voltage Offset Correction: v_off_ini = -62.946 uV, v_off_fin = -72.957 uV 16:55:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.113 uVs 16:55:41 Integrated Voltage Measurement... 16:55:50 Voltage Offset Correction: v_off_ini = -65.813 uV, v_off_fin = -83.613 uV 16:55:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.435 uVs 16:55:50 Integrated Voltage Measurement... 16:55:59 Voltage Offset Correction: v_off_ini = -75.742 uV, v_off_fin = -88.990 uV 16:55:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.065 uVs 16:55:59 Integrated Voltage Measurement... 16:56:08 Voltage Offset Correction: v_off_ini = -75.606 uV, v_off_fin = -74.874 uV 16:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.253 uVs 16:56:11 I2X Average and RMS of Measurements VT = -103.378 +- 4.175 uVs I2X = 9.511 +- 0.384 uTm^2 16:56:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:56:18 Integrated Voltage Measurement... 16:56:27 Voltage Offset Correction: v_off_ini = -86.789 uV, v_off_fin = -93.943 uV 16:56:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.747 uVs 16:56:27 Integrated Voltage Measurement... 16:56:36 Voltage Offset Correction: v_off_ini = -84.623 uV, v_off_fin = -80.763 uV 16:56:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.807 uVs 16:56:36 Integrated Voltage Measurement... 16:56:45 Voltage Offset Correction: v_off_ini = -78.095 uV, v_off_fin = -93.833 uV 16:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.976 uVs 16:56:45 Integrated Voltage Measurement... 16:56:54 Voltage Offset Correction: v_off_ini = -85.690 uV, v_off_fin = -79.180 uV 16:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.722 uVs 16:56:54 Integrated Voltage Measurement... 16:57:03 Voltage Offset Correction: v_off_ini = -76.060 uV, v_off_fin = -79.225 uV 16:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.340 uVs 16:57:03 Integrated Voltage Measurement... 16:57:12 Voltage Offset Correction: v_off_ini = -84.037 uV, v_off_fin = -74.571 uV 16:57:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.946 uVs 16:57:15 I2Y Average and RMS of Measurements VT = -271.923 +- 5.867 uVs I2Y = -25.017 +- 0.540 uTm^2 16:57:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:57:24 Integrated Voltage Measurement... 16:57:33 Voltage Offset Correction: v_off_ini = -93.613 uV, v_off_fin = -93.839 uV 16:57:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.284 uVs 16:57:33 Integrated Voltage Measurement... 16:57:42 Voltage Offset Correction: v_off_ini = -99.138 uV, v_off_fin = -76.183 uV 16:57:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.423 uVs 16:57:42 Integrated Voltage Measurement... 16:57:51 Voltage Offset Correction: v_off_ini = -83.133 uV, v_off_fin = -82.151 uV 16:57:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.050 uVs 16:57:51 Integrated Voltage Measurement... 16:58:00 Voltage Offset Correction: v_off_ini = -81.996 uV, v_off_fin = -82.078 uV 16:58:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.514 uVs 16:58:00 Integrated Voltage Measurement... 16:58:09 Voltage Offset Correction: v_off_ini = -81.913 uV, v_off_fin = -91.570 uV 16:58:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.498 uVs 16:58:09 Integrated Voltage Measurement... 16:58:18 Voltage Offset Correction: v_off_ini = -84.985 uV, v_off_fin = -86.335 uV 16:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.448 uVs 16:58:22 I1X Average and RMS of Measurements VT = -110.536 +- 4.724 uVs I1X = 22.107 +- 0.945 uTm 16:58:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:58:29 Integrated Voltage Measurement... 16:58:38 Voltage Offset Correction: v_off_ini = -101.930 uV, v_off_fin = -111.879 uV 16:58:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -246.971 uVs 16:58:38 Integrated Voltage Measurement... 16:58:47 Voltage Offset Correction: v_off_ini = -97.952 uV, v_off_fin = -81.201 uV 16:58:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.230 uVs 16:58:47 Integrated Voltage Measurement... 16:58:56 Voltage Offset Correction: v_off_ini = -94.514 uV, v_off_fin = -91.338 uV 16:58:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.164 uVs 16:58:56 Integrated Voltage Measurement... 16:59:05 Voltage Offset Correction: v_off_ini = -74.895 uV, v_off_fin = -80.131 uV 16:59:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.530 uVs 16:59:05 Integrated Voltage Measurement... 16:59:14 Voltage Offset Correction: v_off_ini = -91.319 uV, v_off_fin = -120.611 uV 16:59:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.311 uVs 16:59:14 Integrated Voltage Measurement... 16:59:23 Voltage Offset Correction: v_off_ini = -106.707 uV, v_off_fin = -97.943 uV 16:59:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.890 uVs 16:59:27 I1Y Average and RMS of Measurements VT = -250.849 +- 5.692 uVs I1Y = -50.171 +- 1.139 uTm 16:59:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:59:35 Integrated Voltage Measurement... 16:59:44 Voltage Offset Correction: v_off_ini = -105.448 uV, v_off_fin = -108.082 uV 16:59:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.958 uVs 16:59:44 Integrated Voltage Measurement... 16:59:53 Voltage Offset Correction: v_off_ini = -105.507 uV, v_off_fin = -85.563 uV 16:59:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.588 uVs 16:59:53 Integrated Voltage Measurement... 17:00:02 Voltage Offset Correction: v_off_ini = -89.712 uV, v_off_fin = -90.606 uV 17:00:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.596 uVs 17:00:02 Integrated Voltage Measurement... 17:00:11 Voltage Offset Correction: v_off_ini = -95.924 uV, v_off_fin = -75.161 uV 17:00:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.777 uVs 17:00:11 Integrated Voltage Measurement... 17:00:20 Voltage Offset Correction: v_off_ini = -83.311 uV, v_off_fin = -92.888 uV 17:00:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.164 uVs 17:00:20 Integrated Voltage Measurement... 17:00:29 Voltage Offset Correction: v_off_ini = -92.444 uV, v_off_fin = -75.285 uV 17:00:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.608 uVs 17:00:31 I2X Average and RMS of Measurements VT = -116.948 +- 2.320 uVs I2X = 10.759 +- 0.213 uTm^2 17:00:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:00:39 Integrated Voltage Measurement... 17:00:48 Voltage Offset Correction: v_off_ini = -87.406 uV, v_off_fin = -91.140 uV 17:00:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.687 uVs 17:00:48 Integrated Voltage Measurement... 17:00:57 Voltage Offset Correction: v_off_ini = -90.897 uV, v_off_fin = -95.758 uV 17:00:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.889 uVs 17:00:57 Integrated Voltage Measurement... 17:01:06 Voltage Offset Correction: v_off_ini = -86.835 uV, v_off_fin = -90.801 uV 17:01:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.780 uVs 17:01:06 Integrated Voltage Measurement... 17:01:15 Voltage Offset Correction: v_off_ini = -89.967 uV, v_off_fin = -94.701 uV 17:01:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.508 uVs 17:01:15 Integrated Voltage Measurement... 17:01:24 Voltage Offset Correction: v_off_ini = -107.294 uV, v_off_fin = -105.643 uV 17:01:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.919 uVs 17:01:24 Integrated Voltage Measurement... 17:01:33 Voltage Offset Correction: v_off_ini = -94.474 uV, v_off_fin = -97.834 uV 17:01:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 275.602 uVs 17:01:36 I2Y Average and RMS of Measurements VT = -273.897 +- 5.081 uVs I2Y = -25.199 +- 0.468 uTm^2 17:01:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:01:48 Integrated Voltage Measurement... 17:01:57 Voltage Offset Correction: v_off_ini = -89.497 uV, v_off_fin = -98.404 uV 17:01:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -114.036 uVs 17:01:57 Integrated Voltage Measurement... 17:02:06 Voltage Offset Correction: v_off_ini = -84.866 uV, v_off_fin = -88.390 uV 17:02:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 112.526 uVs 17:02:06 Integrated Voltage Measurement... 17:02:15 Voltage Offset Correction: v_off_ini = -82.776 uV, v_off_fin = -77.208 uV 17:02:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.572 uVs 17:02:15 Integrated Voltage Measurement... 17:02:24 Voltage Offset Correction: v_off_ini = -79.605 uV, v_off_fin = -77.311 uV 17:02:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.263 uVs 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = -88.184 uV, v_off_fin = -88.434 uV 17:02:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -104.016 uVs 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = -77.410 uV, v_off_fin = -77.382 uV 17:02:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 111.280 uVs 17:02:46 I1X Average and RMS of Measurements VT = -110.282 +- 2.314 uVs I1X = 22.059 +- 0.463 uTm 17:02:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:02:53 Integrated Voltage Measurement... 17:03:02 Voltage Offset Correction: v_off_ini = -75.030 uV, v_off_fin = -90.387 uV 17:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.044 uVs 17:03:02 Integrated Voltage Measurement... 17:03:11 Voltage Offset Correction: v_off_ini = -72.650 uV, v_off_fin = -75.060 uV 17:03:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.105 uVs 17:03:11 Integrated Voltage Measurement... 17:03:20 Voltage Offset Correction: v_off_ini = -80.953 uV, v_off_fin = -99.811 uV 17:03:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.295 uVs 17:03:20 Integrated Voltage Measurement... 17:03:29 Voltage Offset Correction: v_off_ini = -87.612 uV, v_off_fin = -72.939 uV 17:03:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.754 uVs 17:03:29 Integrated Voltage Measurement... 17:03:38 Voltage Offset Correction: v_off_ini = -78.027 uV, v_off_fin = -99.766 uV 17:03:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.420 uVs 17:03:38 Integrated Voltage Measurement... 17:03:47 Voltage Offset Correction: v_off_ini = -89.982 uV, v_off_fin = -72.874 uV 17:03:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.390 uVs 17:03:51 I1Y Average and RMS of Measurements VT = -244.168 +- 6.309 uVs I1Y = -48.834 +- 1.263 uTm 17:03:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:03:56 Integrated Voltage Measurement... 17:04:05 Voltage Offset Correction: v_off_ini = -90.611 uV, v_off_fin = -80.244 uV 17:04:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.671 uVs 17:04:05 Integrated Voltage Measurement... 17:04:14 Voltage Offset Correction: v_off_ini = -75.488 uV, v_off_fin = -72.329 uV 17:04:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.460 uVs 17:04:14 Integrated Voltage Measurement... 17:04:23 Voltage Offset Correction: v_off_ini = -77.827 uV, v_off_fin = -77.995 uV 17:04:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.941 uVs 17:04:23 Integrated Voltage Measurement... 17:04:32 Voltage Offset Correction: v_off_ini = -74.244 uV, v_off_fin = -73.210 uV 17:04:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.796 uVs 17:04:32 Integrated Voltage Measurement... 17:04:41 Voltage Offset Correction: v_off_ini = -71.533 uV, v_off_fin = -75.947 uV 17:04:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.370 uVs 17:04:42 Integrated Voltage Measurement... 17:04:50 Voltage Offset Correction: v_off_ini = -66.210 uV, v_off_fin = -67.058 uV 17:04:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.617 uVs 17:04:53 I2X Average and RMS of Measurements VT = -101.809 +- 6.180 uVs I2X = 9.366 +- 0.569 uTm^2 17:04:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:04:58 Integrated Voltage Measurement... 17:05:07 Voltage Offset Correction: v_off_ini = -74.756 uV, v_off_fin = -68.643 uV 17:05:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.282 uVs 17:05:07 Integrated Voltage Measurement... 17:05:16 Voltage Offset Correction: v_off_ini = -85.044 uV, v_off_fin = -79.191 uV 17:05:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.902 uVs 17:05:16 Integrated Voltage Measurement... 17:05:25 Voltage Offset Correction: v_off_ini = -89.030 uV, v_off_fin = -85.803 uV 17:05:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.633 uVs 17:05:25 Integrated Voltage Measurement... 17:05:34 Voltage Offset Correction: v_off_ini = -85.759 uV, v_off_fin = -90.641 uV 17:05:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.843 uVs 17:05:34 Integrated Voltage Measurement... 17:05:43 Voltage Offset Correction: v_off_ini = -77.075 uV, v_off_fin = -86.570 uV 17:05:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.956 uVs 17:05:43 Integrated Voltage Measurement... 17:05:52 Voltage Offset Correction: v_off_ini = -76.551 uV, v_off_fin = -64.199 uV 17:05:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.116 uVs 17:05:55 I2Y Average and RMS of Measurements VT = -260.955 +- 7.330 uVs I2Y = -24.008 +- 0.674 uTm^2 17:05:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:06:03 Integrated Voltage Measurement... 17:06:12 Voltage Offset Correction: v_off_ini = -84.257 uV, v_off_fin = -89.329 uV 17:06:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.390 uVs 17:06:12 Integrated Voltage Measurement... 17:06:21 Voltage Offset Correction: v_off_ini = -86.506 uV, v_off_fin = -80.922 uV 17:06:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.866 uVs 17:06:21 Integrated Voltage Measurement... 17:06:30 Voltage Offset Correction: v_off_ini = -81.920 uV, v_off_fin = -91.850 uV 17:06:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.662 uVs 17:06:30 Integrated Voltage Measurement... 17:06:39 Voltage Offset Correction: v_off_ini = -84.468 uV, v_off_fin = -88.579 uV 17:06:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.288 uVs 17:06:39 Integrated Voltage Measurement... 17:06:48 Voltage Offset Correction: v_off_ini = -89.053 uV, v_off_fin = -88.971 uV 17:06:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.608 uVs 17:06:48 Integrated Voltage Measurement... 17:06:57 Voltage Offset Correction: v_off_ini = -92.872 uV, v_off_fin = -81.996 uV 17:06:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.360 uVs 17:07:01 I1X Average and RMS of Measurements VT = -106.696 +- 3.635 uVs I1X = 21.339 +- 0.727 uTm 17:07:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:07:08 Integrated Voltage Measurement... 17:07:17 Voltage Offset Correction: v_off_ini = -74.788 uV, v_off_fin = -79.795 uV 17:07:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.741 uVs 17:07:17 Integrated Voltage Measurement... 17:07:26 Voltage Offset Correction: v_off_ini = -54.048 uV, v_off_fin = -58.734 uV 17:07:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.374 uVs 17:07:26 Integrated Voltage Measurement... 17:07:35 Voltage Offset Correction: v_off_ini = -63.002 uV, v_off_fin = -79.326 uV 17:07:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.887 uVs 17:07:35 Integrated Voltage Measurement... 17:07:44 Voltage Offset Correction: v_off_ini = -69.577 uV, v_off_fin = -56.688 uV 17:07:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.413 uVs 17:07:44 Integrated Voltage Measurement... 17:07:53 Voltage Offset Correction: v_off_ini = -73.329 uV, v_off_fin = -82.375 uV 17:07:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.061 uVs 17:07:53 Integrated Voltage Measurement... 17:08:02 Voltage Offset Correction: v_off_ini = -66.711 uV, v_off_fin = -63.967 uV 17:08:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.802 uVs 17:08:06 I1Y Average and RMS of Measurements VT = -239.713 +- 4.197 uVs I1Y = -47.943 +- 0.839 uTm 17:08:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:08:11 Integrated Voltage Measurement... 17:08:20 Voltage Offset Correction: v_off_ini = -48.419 uV, v_off_fin = -68.359 uV 17:08:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -136.522 uVs 17:08:20 Integrated Voltage Measurement... 17:08:29 Voltage Offset Correction: v_off_ini = -80.718 uV, v_off_fin = -63.383 uV 17:08:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.761 uVs 17:08:30 Integrated Voltage Measurement... 17:08:38 Voltage Offset Correction: v_off_ini = -76.499 uV, v_off_fin = -93.666 uV 17:08:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.014 uVs 17:08:39 Integrated Voltage Measurement... 17:08:48 Voltage Offset Correction: v_off_ini = -68.243 uV, v_off_fin = -70.009 uV 17:08:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.834 uVs 17:08:48 Integrated Voltage Measurement... 17:08:57 Voltage Offset Correction: v_off_ini = -78.204 uV, v_off_fin = -67.927 uV 17:08:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.545 uVs 17:08:57 Integrated Voltage Measurement... 17:09:06 Voltage Offset Correction: v_off_ini = -66.302 uV, v_off_fin = -58.530 uV 17:09:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.269 uVs 17:09:08 I2X Average and RMS of Measurements VT = -113.824 +- 2.335 uVs I2X = 10.472 +- 0.215 uTm^2 17:09:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:09:13 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = -61.740 uV, v_off_fin = -83.194 uV 17:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.357 uVs 17:09:22 Integrated Voltage Measurement... 17:09:31 Voltage Offset Correction: v_off_ini = -69.449 uV, v_off_fin = -72.242 uV 17:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.221 uVs 17:09:31 Integrated Voltage Measurement... 17:09:40 Voltage Offset Correction: v_off_ini = -65.121 uV, v_off_fin = -71.096 uV 17:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.160 uVs 17:09:40 Integrated Voltage Measurement... 17:09:49 Voltage Offset Correction: v_off_ini = -70.060 uV, v_off_fin = -78.506 uV 17:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.475 uVs 17:09:49 Integrated Voltage Measurement... 17:09:58 Voltage Offset Correction: v_off_ini = -82.602 uV, v_off_fin = -82.874 uV 17:09:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.428 uVs 17:09:58 Integrated Voltage Measurement... 17:10:07 Voltage Offset Correction: v_off_ini = -55.947 uV, v_off_fin = -69.262 uV 17:10:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.378 uVs 17:10:10 I2Y Average and RMS of Measurements VT = -258.003 +- 3.063 uVs I2Y = -23.736 +- 0.282 uTm^2 17:10:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:18 Integrated Voltage Measurement... 17:10:27 Voltage Offset Correction: v_off_ini = -77.674 uV, v_off_fin = -85.760 uV 17:10:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.536 uVs 17:10:27 Integrated Voltage Measurement... 17:10:36 Voltage Offset Correction: v_off_ini = -71.647 uV, v_off_fin = -73.046 uV 17:10:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.365 uVs 17:10:36 Integrated Voltage Measurement... 17:10:45 Voltage Offset Correction: v_off_ini = -75.312 uV, v_off_fin = -67.231 uV 17:10:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.921 uVs 17:10:45 Integrated Voltage Measurement... 17:10:54 Voltage Offset Correction: v_off_ini = -65.597 uV, v_off_fin = -64.754 uV 17:10:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.269 uVs 17:10:54 Integrated Voltage Measurement... 17:11:03 Voltage Offset Correction: v_off_ini = -81.799 uV, v_off_fin = -76.149 uV 17:11:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.920 uVs 17:11:03 Integrated Voltage Measurement... 17:11:12 Voltage Offset Correction: v_off_ini = -83.606 uV, v_off_fin = -81.944 uV 17:11:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.509 uVs 17:11:16 I1X Average and RMS of Measurements VT = -103.920 +- 5.964 uVs I1X = 20.784 +- 1.192 uTm 17:11:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:23 Integrated Voltage Measurement... 17:11:32 Voltage Offset Correction: v_off_ini = -94.102 uV, v_off_fin = -96.927 uV 17:11:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.315 uVs 17:11:32 Integrated Voltage Measurement... 17:11:41 Voltage Offset Correction: v_off_ini = -86.823 uV, v_off_fin = -73.007 uV 17:11:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.274 uVs 17:11:41 Integrated Voltage Measurement... 17:11:50 Voltage Offset Correction: v_off_ini = -78.963 uV, v_off_fin = -89.766 uV 17:11:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.924 uVs 17:11:50 Integrated Voltage Measurement... 17:11:59 Voltage Offset Correction: v_off_ini = -77.289 uV, v_off_fin = -74.098 uV 17:11:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.928 uVs 17:11:59 Integrated Voltage Measurement... 17:12:08 Voltage Offset Correction: v_off_ini = -80.253 uV, v_off_fin = -94.151 uV 17:12:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.345 uVs 17:12:08 Integrated Voltage Measurement... 17:12:17 Voltage Offset Correction: v_off_ini = -79.130 uV, v_off_fin = -61.428 uV 17:12:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.798 uVs 17:12:21 I1Y Average and RMS of Measurements VT = -237.764 +- 4.037 uVs I1Y = -47.553 +- 0.807 uTm 17:12:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:27 Integrated Voltage Measurement... 17:12:36 Voltage Offset Correction: v_off_ini = -62.802 uV, v_off_fin = -80.663 uV 17:12:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.535 uVs 17:12:36 Integrated Voltage Measurement... 17:12:45 Voltage Offset Correction: v_off_ini = -67.437 uV, v_off_fin = -58.550 uV 17:12:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.295 uVs 17:12:45 Integrated Voltage Measurement... 17:12:54 Voltage Offset Correction: v_off_ini = -66.259 uV, v_off_fin = -74.926 uV 17:12:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.683 uVs 17:12:54 Integrated Voltage Measurement... 17:13:03 Voltage Offset Correction: v_off_ini = -59.599 uV, v_off_fin = -61.537 uV 17:13:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.314 uVs 17:13:03 Integrated Voltage Measurement... 17:13:12 Voltage Offset Correction: v_off_ini = -67.706 uV, v_off_fin = -79.705 uV 17:13:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.655 uVs 17:13:12 Integrated Voltage Measurement... 17:13:21 Voltage Offset Correction: v_off_ini = -59.870 uV, v_off_fin = -50.003 uV 17:13:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.150 uVs 17:13:23 I2X Average and RMS of Measurements VT = -101.939 +- 6.908 uVs I2X = 9.378 +- 0.636 uTm^2 17:13:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:28 Integrated Voltage Measurement... 17:13:37 Voltage Offset Correction: v_off_ini = -70.699 uV, v_off_fin = -80.077 uV 17:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.169 uVs 17:13:37 Integrated Voltage Measurement... 17:13:46 Voltage Offset Correction: v_off_ini = -83.038 uV, v_off_fin = -80.090 uV 17:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.610 uVs 17:13:46 Integrated Voltage Measurement... 17:13:55 Voltage Offset Correction: v_off_ini = -80.270 uV, v_off_fin = -82.422 uV 17:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.639 uVs 17:13:55 Integrated Voltage Measurement... 17:14:04 Voltage Offset Correction: v_off_ini = -83.411 uV, v_off_fin = -81.821 uV 17:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.526 uVs 17:14:04 Integrated Voltage Measurement... 17:14:13 Voltage Offset Correction: v_off_ini = -80.831 uV, v_off_fin = -75.516 uV 17:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.833 uVs 17:14:14 Integrated Voltage Measurement... 17:14:22 Voltage Offset Correction: v_off_ini = -86.345 uV, v_off_fin = -65.990 uV 17:14:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.839 uVs 17:14:25 I2Y Average and RMS of Measurements VT = -259.936 +- 8.866 uVs I2Y = -23.914 +- 0.816 uTm^2 17:14:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:14:33 Integrated Voltage Measurement... 17:14:42 Voltage Offset Correction: v_off_ini = -74.840 uV, v_off_fin = -70.978 uV 17:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -129.999 uVs 17:14:42 Integrated Voltage Measurement... 17:14:51 Voltage Offset Correction: v_off_ini = -67.947 uV, v_off_fin = -66.965 uV 17:14:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.152 uVs 17:14:51 Integrated Voltage Measurement... 17:15:00 Voltage Offset Correction: v_off_ini = -80.685 uV, v_off_fin = -79.291 uV 17:15:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.714 uVs 17:15:00 Integrated Voltage Measurement... 17:15:09 Voltage Offset Correction: v_off_ini = -84.125 uV, v_off_fin = -84.441 uV 17:15:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.093 uVs 17:15:09 Integrated Voltage Measurement... 17:15:18 Voltage Offset Correction: v_off_ini = -76.973 uV, v_off_fin = -77.074 uV 17:15:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.154 uVs 17:15:18 Integrated Voltage Measurement... 17:15:27 Voltage Offset Correction: v_off_ini = -64.585 uV, v_off_fin = -63.817 uV 17:15:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.495 uVs 17:15:32 I1X Average and RMS of Measurements VT = -106.268 +- 8.551 uVs I1X = 21.254 +- 1.711 uTm 17:15:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:15:38 Integrated Voltage Measurement... 17:15:47 Voltage Offset Correction: v_off_ini = -63.625 uV, v_off_fin = -77.061 uV 17:15:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.354 uVs 17:15:47 Integrated Voltage Measurement... 17:15:56 Voltage Offset Correction: v_off_ini = -74.670 uV, v_off_fin = -65.554 uV 17:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.230 uVs 17:15:56 Integrated Voltage Measurement... 17:16:05 Voltage Offset Correction: v_off_ini = -70.516 uV, v_off_fin = -80.980 uV 17:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.091 uVs 17:16:05 Integrated Voltage Measurement... 17:16:14 Voltage Offset Correction: v_off_ini = -68.104 uV, v_off_fin = -59.559 uV 17:16:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 254.302 uVs 17:16:14 Integrated Voltage Measurement... 17:16:23 Voltage Offset Correction: v_off_ini = -67.971 uV, v_off_fin = -83.049 uV 17:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -233.206 uVs 17:16:23 Integrated Voltage Measurement... 17:16:32 Voltage Offset Correction: v_off_ini = -62.287 uV, v_off_fin = -47.752 uV 17:16:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.403 uVs 17:16:37 I1Y Average and RMS of Measurements VT = -240.598 +- 3.523 uVs I1Y = -48.117 +- 0.706 uTm 17:16:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:16:42 Integrated Voltage Measurement... 17:16:51 Voltage Offset Correction: v_off_ini = -59.305 uV, v_off_fin = -67.340 uV 17:16:51 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -127.351 uVs 17:16:51 Integrated Voltage Measurement... 17:17:00 Voltage Offset Correction: v_off_ini = -67.653 uV, v_off_fin = -61.489 uV 17:17:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.641 uVs 17:17:00 Integrated Voltage Measurement... 17:17:09 Voltage Offset Correction: v_off_ini = -61.297 uV, v_off_fin = -67.365 uV 17:17:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.294 uVs 17:17:09 Integrated Voltage Measurement... 17:17:18 Voltage Offset Correction: v_off_ini = -66.372 uV, v_off_fin = -62.055 uV 17:17:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.752 uVs 17:17:18 Integrated Voltage Measurement... 17:17:27 Voltage Offset Correction: v_off_ini = -75.665 uV, v_off_fin = -72.065 uV 17:17:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.599 uVs 17:17:27 Integrated Voltage Measurement... 17:17:36 Voltage Offset Correction: v_off_ini = -63.910 uV, v_off_fin = -53.018 uV 17:17:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.203 uVs 17:17:38 I2X Average and RMS of Measurements VT = -109.473 +- 7.794 uVs I2X = 10.071 +- 0.717 uTm^2 17:17:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:17:44 Integrated Voltage Measurement... 17:17:53 Voltage Offset Correction: v_off_ini = -62.203 uV, v_off_fin = -58.362 uV 17:17:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.652 uVs 17:17:53 Integrated Voltage Measurement... 17:18:02 Voltage Offset Correction: v_off_ini = -48.985 uV, v_off_fin = -57.441 uV 17:18:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.139 uVs 17:18:02 Integrated Voltage Measurement... 17:18:11 Voltage Offset Correction: v_off_ini = -58.929 uV, v_off_fin = -47.197 uV 17:18:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.488 uVs 17:18:11 Integrated Voltage Measurement... 17:18:20 Voltage Offset Correction: v_off_ini = -52.354 uV, v_off_fin = -56.277 uV 17:18:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.704 uVs 17:18:20 Integrated Voltage Measurement... 17:18:29 Voltage Offset Correction: v_off_ini = -64.103 uV, v_off_fin = -75.534 uV 17:18:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.985 uVs 17:18:29 Integrated Voltage Measurement... 17:18:38 Voltage Offset Correction: v_off_ini = -79.835 uV, v_off_fin = -70.486 uV 17:18:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.801 uVs 17:18:40 I2Y Average and RMS of Measurements VT = -253.462 +- 5.658 uVs I2Y = -23.318 +- 0.521 uTm^2 17:18:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:18:48 Integrated Voltage Measurement... 17:18:57 Voltage Offset Correction: v_off_ini = -71.218 uV, v_off_fin = -76.479 uV 17:18:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.506 uVs 17:18:58 Integrated Voltage Measurement... 17:19:06 Voltage Offset Correction: v_off_ini = -70.236 uV, v_off_fin = -71.470 uV 17:19:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.384 uVs 17:19:07 Integrated Voltage Measurement... 17:19:16 Voltage Offset Correction: v_off_ini = -88.573 uV, v_off_fin = -75.785 uV 17:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.096 uVs 17:19:16 Integrated Voltage Measurement... 17:19:25 Voltage Offset Correction: v_off_ini = -76.596 uV, v_off_fin = -70.596 uV 17:19:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.719 uVs 17:19:25 Integrated Voltage Measurement... 17:19:34 Voltage Offset Correction: v_off_ini = -72.568 uV, v_off_fin = -71.680 uV 17:19:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.448 uVs 17:19:34 Integrated Voltage Measurement... 17:19:43 Voltage Offset Correction: v_off_ini = -80.996 uV, v_off_fin = -85.859 uV 17:19:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.137 uVs 17:19:47 I1X Average and RMS of Measurements VT = -96.882 +- 7.516 uVs I1X = 19.377 +- 1.503 uTm 17:19:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:19:54 Integrated Voltage Measurement... 17:20:03 Voltage Offset Correction: v_off_ini = -91.342 uV, v_off_fin = -111.758 uV 17:20:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.748 uVs 17:20:03 Integrated Voltage Measurement... 17:20:12 Voltage Offset Correction: v_off_ini = -99.986 uV, v_off_fin = -84.047 uV 17:20:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 243.355 uVs 17:20:12 Integrated Voltage Measurement... 17:20:21 Voltage Offset Correction: v_off_ini = -86.234 uV, v_off_fin = -108.895 uV 17:20:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.486 uVs 17:20:21 Integrated Voltage Measurement... 17:20:30 Voltage Offset Correction: v_off_ini = -90.285 uV, v_off_fin = -78.092 uV 17:20:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.620 uVs 17:20:30 Integrated Voltage Measurement... 17:20:39 Voltage Offset Correction: v_off_ini = -85.195 uV, v_off_fin = -106.624 uV 17:20:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -251.398 uVs 17:20:39 Integrated Voltage Measurement... 17:20:48 Voltage Offset Correction: v_off_ini = -84.427 uV, v_off_fin = -90.873 uV 17:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.528 uVs 17:20:52 I1Y Average and RMS of Measurements VT = -237.856 +- 6.469 uVs I1Y = -47.569 +- 1.294 uTm 17:20:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:20:57 Integrated Voltage Measurement... 17:21:06 Voltage Offset Correction: v_off_ini = -98.499 uV, v_off_fin = -99.355 uV 17:21:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.470 uVs 17:21:06 Integrated Voltage Measurement... 17:21:15 Voltage Offset Correction: v_off_ini = -101.313 uV, v_off_fin = -82.827 uV 17:21:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.761 uVs 17:21:15 Integrated Voltage Measurement... 17:21:24 Voltage Offset Correction: v_off_ini = -95.923 uV, v_off_fin = -90.263 uV 17:21:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.578 uVs 17:21:24 Integrated Voltage Measurement... 17:21:33 Voltage Offset Correction: v_off_ini = -88.658 uV, v_off_fin = -74.663 uV 17:21:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.835 uVs 17:21:33 Integrated Voltage Measurement... 17:21:42 Voltage Offset Correction: v_off_ini = -80.143 uV, v_off_fin = -88.678 uV 17:21:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.324 uVs 17:21:42 Integrated Voltage Measurement... 17:21:51 Voltage Offset Correction: v_off_ini = -75.388 uV, v_off_fin = -73.119 uV 17:21:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.644 uVs 17:21:54 I2X Average and RMS of Measurements VT = -94.935 +- 3.347 uVs I2X = 8.734 +- 0.308 uTm^2 17:21:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:21:59 Integrated Voltage Measurement... 17:22:08 Voltage Offset Correction: v_off_ini = -80.297 uV, v_off_fin = -96.389 uV 17:22:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.891 uVs 17:22:08 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = -82.827 uV, v_off_fin = -83.091 uV 17:22:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.467 uVs 17:22:17 Integrated Voltage Measurement... 17:22:26 Voltage Offset Correction: v_off_ini = -73.135 uV, v_off_fin = -67.437 uV 17:22:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -253.686 uVs 17:22:26 Integrated Voltage Measurement... 17:22:35 Voltage Offset Correction: v_off_ini = -65.197 uV, v_off_fin = -69.445 uV 17:22:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.699 uVs 17:22:35 Integrated Voltage Measurement... 17:22:44 Voltage Offset Correction: v_off_ini = -62.235 uV, v_off_fin = -63.161 uV 17:22:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.217 uVs 17:22:44 Integrated Voltage Measurement... 17:22:53 Voltage Offset Correction: v_off_ini = -56.712 uV, v_off_fin = -50.661 uV 17:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.413 uVs 17:22:55 I2Y Average and RMS of Measurements VT = -254.895 +- 5.139 uVs I2Y = -23.451 +- 0.472 uTm^2 17:23:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm