SLAC Magnetic Measurements Date: 09-03-2025 Time: 13:49:38 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16340 Dataset Number: 1 Run Purpose: tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 13:49:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:48 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:49:50 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:49:52 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:49:53 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:50:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:48 Integrated Voltage Measurement... 13:50:57 Voltage Offset Correction: v_off_ini = -293.049 uV, v_off_fin = -286.111 uV 13:50:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.796 uVs 13:50:57 Integrated Voltage Measurement... 13:51:06 Voltage Offset Correction: v_off_ini = -290.391 uV, v_off_fin = -278.880 uV 13:51:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.126 uVs 13:51:06 Integrated Voltage Measurement... 13:51:15 Voltage Offset Correction: v_off_ini = -291.007 uV, v_off_fin = -294.055 uV 13:51:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.232 uVs 13:51:15 Integrated Voltage Measurement... 13:51:24 Voltage Offset Correction: v_off_ini = -295.549 uV, v_off_fin = -281.709 uV 13:51:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.013 uVs 13:51:24 Integrated Voltage Measurement... 13:51:33 Voltage Offset Correction: v_off_ini = -286.133 uV, v_off_fin = -279.021 uV 13:51:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.391 uVs 13:51:33 Integrated Voltage Measurement... 13:51:42 Voltage Offset Correction: v_off_ini = -268.818 uV, v_off_fin = -270.583 uV 13:51:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.375 uVs 13:51:47 I1X Average and RMS of Measurements VT = -86.822 +- 1.597 uVs I1X = 17.365 +- 0.320 uTm 13:51:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:53 Integrated Voltage Measurement... 13:52:02 Voltage Offset Correction: v_off_ini = -276.043 uV, v_off_fin = -289.688 uV 13:52:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.255 uVs 13:52:02 Integrated Voltage Measurement... 13:52:11 Voltage Offset Correction: v_off_ini = -276.418 uV, v_off_fin = -268.279 uV 13:52:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 191.594 uVs 13:52:11 Integrated Voltage Measurement... 13:52:20 Voltage Offset Correction: v_off_ini = -275.681 uV, v_off_fin = -291.932 uV 13:52:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.230 uVs 13:52:20 Integrated Voltage Measurement... 13:52:29 Voltage Offset Correction: v_off_ini = -276.202 uV, v_off_fin = -260.907 uV 13:52:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.980 uVs 13:52:29 Integrated Voltage Measurement... 13:52:38 Voltage Offset Correction: v_off_ini = -274.497 uV, v_off_fin = -281.334 uV 13:52:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.498 uVs 13:52:38 Integrated Voltage Measurement... 13:52:47 Voltage Offset Correction: v_off_ini = -290.458 uV, v_off_fin = -273.397 uV 13:52:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.854 uVs 13:52:52 I1Y Average and RMS of Measurements VT = -196.235 +- 3.661 uVs I1Y = -39.243 +- 0.732 uTm 13:52:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:59 Integrated Voltage Measurement... 13:53:08 Voltage Offset Correction: v_off_ini = -292.086 uV, v_off_fin = -286.470 uV 13:53:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.745 uVs 13:53:09 Integrated Voltage Measurement... 13:53:18 Voltage Offset Correction: v_off_ini = -273.738 uV, v_off_fin = -263.514 uV 13:53:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.032 uVs 13:53:18 Integrated Voltage Measurement... 13:53:27 Voltage Offset Correction: v_off_ini = -274.474 uV, v_off_fin = -281.455 uV 13:53:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.403 uVs 13:53:27 Integrated Voltage Measurement... 13:53:36 Voltage Offset Correction: v_off_ini = -271.365 uV, v_off_fin = -256.134 uV 13:53:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.240 uVs 13:53:36 Integrated Voltage Measurement... 13:53:45 Voltage Offset Correction: v_off_ini = -256.956 uV, v_off_fin = -288.980 uV 13:53:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.931 uVs 13:53:45 Integrated Voltage Measurement... 13:53:54 Voltage Offset Correction: v_off_ini = -263.310 uV, v_off_fin = -256.580 uV 13:53:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.822 uVs 13:53:56 I2X Average and RMS of Measurements VT = -68.029 +- 10.106 uVs I2X = 6.259 +- 0.930 uTm^2 13:54:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:04 Integrated Voltage Measurement... 13:54:13 Voltage Offset Correction: v_off_ini = -258.435 uV, v_off_fin = -246.162 uV 13:54:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.493 uVs 13:54:13 Integrated Voltage Measurement... 13:54:22 Voltage Offset Correction: v_off_ini = -239.164 uV, v_off_fin = -239.696 uV 13:54:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.608 uVs 13:54:22 Integrated Voltage Measurement... 13:54:31 Voltage Offset Correction: v_off_ini = -246.374 uV, v_off_fin = -236.558 uV 13:54:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.969 uVs 13:54:31 Integrated Voltage Measurement... 13:54:40 Voltage Offset Correction: v_off_ini = -238.930 uV, v_off_fin = -239.409 uV 13:54:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.349 uVs 13:54:40 Integrated Voltage Measurement... 13:54:49 Voltage Offset Correction: v_off_ini = -241.640 uV, v_off_fin = -233.435 uV 13:54:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.822 uVs 13:54:49 Integrated Voltage Measurement... 13:54:58 Voltage Offset Correction: v_off_ini = -233.942 uV, v_off_fin = -238.040 uV 13:54:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.660 uVs 13:55:01 I2Y Average and RMS of Measurements VT = -257.817 +- 5.412 uVs I2Y = -23.719 +- 0.498 uTm^2 13:55:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:16 Integrated Voltage Measurement... 13:55:25 Voltage Offset Correction: v_off_ini = -236.015 uV, v_off_fin = -245.984 uV 13:55:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.794 uVs 13:55:25 Integrated Voltage Measurement... 13:55:34 Voltage Offset Correction: v_off_ini = -230.634 uV, v_off_fin = -234.302 uV 13:55:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.030 uVs 13:55:34 Integrated Voltage Measurement... 13:55:43 Voltage Offset Correction: v_off_ini = -238.538 uV, v_off_fin = -246.865 uV 13:55:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.438 uVs 13:55:43 Integrated Voltage Measurement... 13:55:52 Voltage Offset Correction: v_off_ini = -236.070 uV, v_off_fin = -238.925 uV 13:55:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.873 uVs 13:55:52 Integrated Voltage Measurement... 13:56:01 Voltage Offset Correction: v_off_ini = -230.748 uV, v_off_fin = -241.580 uV 13:56:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.931 uVs 13:56:01 Integrated Voltage Measurement... 13:56:10 Voltage Offset Correction: v_off_ini = -241.547 uV, v_off_fin = -221.369 uV 13:56:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.237 uVs 13:56:14 I1X Average and RMS of Measurements VT = -96.717 +- 5.832 uVs I1X = 19.344 +- 1.166 uTm 13:56:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:21 Integrated Voltage Measurement... 13:56:30 Voltage Offset Correction: v_off_ini = -228.914 uV, v_off_fin = -239.824 uV 13:56:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -200.288 uVs 13:56:30 Integrated Voltage Measurement... 13:56:39 Voltage Offset Correction: v_off_ini = -237.525 uV, v_off_fin = -224.109 uV 13:56:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.420 uVs 13:56:39 Integrated Voltage Measurement... 13:56:48 Voltage Offset Correction: v_off_ini = -235.160 uV, v_off_fin = -247.258 uV 13:56:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.741 uVs 13:56:48 Integrated Voltage Measurement... 13:56:57 Voltage Offset Correction: v_off_ini = -231.387 uV, v_off_fin = -231.875 uV 13:56:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.516 uVs 13:56:57 Integrated Voltage Measurement... 13:57:06 Voltage Offset Correction: v_off_ini = -218.609 uV, v_off_fin = -232.634 uV 13:57:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.479 uVs 13:57:06 Integrated Voltage Measurement... 13:57:15 Voltage Offset Correction: v_off_ini = -229.186 uV, v_off_fin = -216.506 uV 13:57:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.134 uVs 13:57:19 I1Y Average and RMS of Measurements VT = -201.930 +- 5.658 uVs I1Y = -40.387 +- 1.132 uTm 13:57:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:27 Integrated Voltage Measurement... 13:57:36 Voltage Offset Correction: v_off_ini = -217.688 uV, v_off_fin = -206.600 uV 13:57:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -73.378 uVs 13:57:36 Integrated Voltage Measurement... 13:57:45 Voltage Offset Correction: v_off_ini = -204.260 uV, v_off_fin = -204.883 uV 13:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.941 uVs 13:57:45 Integrated Voltage Measurement... 13:57:54 Voltage Offset Correction: v_off_ini = -212.626 uV, v_off_fin = -213.483 uV 13:57:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.389 uVs 13:57:54 Integrated Voltage Measurement... 13:58:03 Voltage Offset Correction: v_off_ini = -215.096 uV, v_off_fin = -193.254 uV 13:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.846 uVs 13:58:03 Integrated Voltage Measurement... 13:58:12 Voltage Offset Correction: v_off_ini = -201.246 uV, v_off_fin = -214.995 uV 13:58:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.974 uVs 13:58:12 Integrated Voltage Measurement... 13:58:21 Voltage Offset Correction: v_off_ini = -206.219 uV, v_off_fin = -210.707 uV 13:58:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.156 uVs 13:58:24 I2X Average and RMS of Measurements VT = -71.280 +- 5.770 uVs I2X = 6.558 +- 0.531 uTm^2 13:58:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:31 Integrated Voltage Measurement... 13:58:40 Voltage Offset Correction: v_off_ini = -198.890 uV, v_off_fin = -202.991 uV 13:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.866 uVs 13:58:41 Integrated Voltage Measurement... 13:58:49 Voltage Offset Correction: v_off_ini = -214.727 uV, v_off_fin = -207.276 uV 13:58:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.386 uVs 13:58:50 Integrated Voltage Measurement... 13:58:59 Voltage Offset Correction: v_off_ini = -210.293 uV, v_off_fin = -204.037 uV 13:58:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.086 uVs 13:58:59 Integrated Voltage Measurement... 13:59:08 Voltage Offset Correction: v_off_ini = -210.157 uV, v_off_fin = -197.353 uV 13:59:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.251 uVs 13:59:08 Integrated Voltage Measurement... 13:59:17 Voltage Offset Correction: v_off_ini = -198.432 uV, v_off_fin = -215.505 uV 13:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.286 uVs 13:59:17 Integrated Voltage Measurement... 13:59:26 Voltage Offset Correction: v_off_ini = -205.309 uV, v_off_fin = -197.370 uV 13:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.772 uVs 13:59:28 I2Y Average and RMS of Measurements VT = -263.608 +- 7.097 uVs I2Y = -24.252 +- 0.653 uTm^2 13:59:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:43 Integrated Voltage Measurement... 13:59:52 Voltage Offset Correction: v_off_ini = -207.041 uV, v_off_fin = -212.967 uV 13:59:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.951 uVs 13:59:52 Integrated Voltage Measurement... 14:00:01 Voltage Offset Correction: v_off_ini = -206.588 uV, v_off_fin = -198.808 uV 14:00:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.722 uVs 14:00:01 Integrated Voltage Measurement... 14:00:10 Voltage Offset Correction: v_off_ini = -202.864 uV, v_off_fin = -209.291 uV 14:00:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.132 uVs 14:00:10 Integrated Voltage Measurement... 14:00:19 Voltage Offset Correction: v_off_ini = -194.509 uV, v_off_fin = -200.500 uV 14:00:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.866 uVs 14:00:19 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = -213.376 uV, v_off_fin = -202.331 uV 14:00:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.145 uVs 14:00:28 Integrated Voltage Measurement... 14:00:37 Voltage Offset Correction: v_off_ini = -196.841 uV, v_off_fin = -195.913 uV 14:00:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.395 uVs 14:00:42 I1X Average and RMS of Measurements VT = -99.868 +- 0.392 uVs I1X = 19.974 +- 0.078 uTm 14:00:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:48 Integrated Voltage Measurement... 14:00:57 Voltage Offset Correction: v_off_ini = -194.612 uV, v_off_fin = -216.472 uV 14:00:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.694 uVs 14:00:57 Integrated Voltage Measurement... 14:01:06 Voltage Offset Correction: v_off_ini = -209.327 uV, v_off_fin = -201.200 uV 14:01:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.041 uVs 14:01:06 Integrated Voltage Measurement... 14:01:15 Voltage Offset Correction: v_off_ini = -202.594 uV, v_off_fin = -217.228 uV 14:01:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.234 uVs 14:01:15 Integrated Voltage Measurement... 14:01:24 Voltage Offset Correction: v_off_ini = -212.947 uV, v_off_fin = -194.626 uV 14:01:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.808 uVs 14:01:24 Integrated Voltage Measurement... 14:01:33 Voltage Offset Correction: v_off_ini = -194.979 uV, v_off_fin = -203.984 uV 14:01:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.593 uVs 14:01:34 Integrated Voltage Measurement... 14:01:42 Voltage Offset Correction: v_off_ini = -193.982 uV, v_off_fin = -186.571 uV 14:01:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.544 uVs 14:01:47 I1Y Average and RMS of Measurements VT = -201.319 +- 2.568 uVs I1Y = -40.262 +- 0.513 uTm 14:01:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:54 Integrated Voltage Measurement... 14:02:03 Voltage Offset Correction: v_off_ini = -202.279 uV, v_off_fin = -211.527 uV 14:02:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.618 uVs 14:02:04 Integrated Voltage Measurement... 14:02:13 Voltage Offset Correction: v_off_ini = -200.813 uV, v_off_fin = -190.600 uV 14:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.742 uVs 14:02:13 Integrated Voltage Measurement... 14:02:22 Voltage Offset Correction: v_off_ini = -201.183 uV, v_off_fin = -210.150 uV 14:02:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.524 uVs 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = -208.989 uV, v_off_fin = -205.465 uV 14:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.378 uVs 14:02:31 Integrated Voltage Measurement... 14:02:40 Voltage Offset Correction: v_off_ini = -219.790 uV, v_off_fin = -219.999 uV 14:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.830 uVs 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = -201.546 uV, v_off_fin = -197.127 uV 14:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.994 uVs 14:02:51 I2X Average and RMS of Measurements VT = -84.515 +- 4.316 uVs I2X = 7.775 +- 0.397 uTm^2 14:02:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:59 Integrated Voltage Measurement... 14:03:08 Voltage Offset Correction: v_off_ini = -215.515 uV, v_off_fin = -209.198 uV 14:03:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.622 uVs 14:03:08 Integrated Voltage Measurement... 14:03:17 Voltage Offset Correction: v_off_ini = -223.165 uV, v_off_fin = -207.585 uV 14:03:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.129 uVs 14:03:17 Integrated Voltage Measurement... 14:03:26 Voltage Offset Correction: v_off_ini = -211.891 uV, v_off_fin = -212.663 uV 14:03:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.395 uVs 14:03:26 Integrated Voltage Measurement... 14:03:35 Voltage Offset Correction: v_off_ini = -200.177 uV, v_off_fin = -205.688 uV 14:03:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.079 uVs 14:03:35 Integrated Voltage Measurement... 14:03:44 Voltage Offset Correction: v_off_ini = -205.572 uV, v_off_fin = -206.429 uV 14:03:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.082 uVs 14:03:44 Integrated Voltage Measurement... 14:03:53 Voltage Offset Correction: v_off_ini = -207.777 uV, v_off_fin = -195.759 uV 14:03:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.385 uVs 14:03:56 I2Y Average and RMS of Measurements VT = -248.116 +- 5.511 uVs I2Y = -22.827 +- 0.507 uTm^2 14:04:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:11 Integrated Voltage Measurement... 14:04:20 Voltage Offset Correction: v_off_ini = -203.785 uV, v_off_fin = -204.610 uV 14:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.791 uVs 14:04:20 Integrated Voltage Measurement... 14:04:29 Voltage Offset Correction: v_off_ini = -196.182 uV, v_off_fin = -188.122 uV 14:04:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.065 uVs 14:04:29 Integrated Voltage Measurement... 14:04:38 Voltage Offset Correction: v_off_ini = -185.914 uV, v_off_fin = -197.222 uV 14:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.763 uVs 14:04:38 Integrated Voltage Measurement... 14:04:47 Voltage Offset Correction: v_off_ini = -200.377 uV, v_off_fin = -189.279 uV 14:04:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.569 uVs 14:04:47 Integrated Voltage Measurement... 14:04:56 Voltage Offset Correction: v_off_ini = -191.239 uV, v_off_fin = -187.458 uV 14:04:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.915 uVs 14:04:56 Integrated Voltage Measurement... 14:05:05 Voltage Offset Correction: v_off_ini = -187.673 uV, v_off_fin = -177.404 uV 14:05:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.782 uVs 14:05:09 I1X Average and RMS of Measurements VT = -103.314 +- 11.856 uVs I1X = 20.663 +- 2.371 uTm 14:05:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:16 Integrated Voltage Measurement... 14:05:25 Voltage Offset Correction: v_off_ini = -188.020 uV, v_off_fin = -192.967 uV 14:05:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.153 uVs 14:05:25 Integrated Voltage Measurement... 14:05:34 Voltage Offset Correction: v_off_ini = -168.056 uV, v_off_fin = -153.727 uV 14:05:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 198.743 uVs 14:05:34 Integrated Voltage Measurement... 14:05:43 Voltage Offset Correction: v_off_ini = -173.092 uV, v_off_fin = -181.019 uV 14:05:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.625 uVs 14:05:44 Integrated Voltage Measurement... 14:05:53 Voltage Offset Correction: v_off_ini = -169.081 uV, v_off_fin = -163.910 uV 14:05:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.562 uVs 14:05:53 Integrated Voltage Measurement... 14:06:02 Voltage Offset Correction: v_off_ini = -168.249 uV, v_off_fin = -183.371 uV 14:06:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.546 uVs 14:06:02 Integrated Voltage Measurement... 14:06:11 Voltage Offset Correction: v_off_ini = -180.747 uV, v_off_fin = -172.630 uV 14:06:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.691 uVs 14:06:15 I1Y Average and RMS of Measurements VT = -199.053 +- 3.792 uVs I1Y = -39.806 +- 0.759 uTm 14:06:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:23 Integrated Voltage Measurement... 14:06:32 Voltage Offset Correction: v_off_ini = -165.501 uV, v_off_fin = -181.619 uV 14:06:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.000 uVs 14:06:32 Integrated Voltage Measurement... 14:06:41 Voltage Offset Correction: v_off_ini = -176.219 uV, v_off_fin = -164.606 uV 14:06:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.330 uVs 14:06:41 Integrated Voltage Measurement... 14:06:50 Voltage Offset Correction: v_off_ini = -165.022 uV, v_off_fin = -179.602 uV 14:06:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.052 uVs 14:06:50 Integrated Voltage Measurement... 14:06:59 Voltage Offset Correction: v_off_ini = -165.790 uV, v_off_fin = -169.025 uV 14:06:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.158 uVs 14:06:59 Integrated Voltage Measurement... 14:07:08 Voltage Offset Correction: v_off_ini = -157.399 uV, v_off_fin = -175.469 uV 14:07:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.287 uVs 14:07:08 Integrated Voltage Measurement... 14:07:17 Voltage Offset Correction: v_off_ini = -181.132 uV, v_off_fin = -162.588 uV 14:07:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.226 uVs 14:07:20 I2X Average and RMS of Measurements VT = -97.676 +- 5.946 uVs I2X = 8.986 +- 0.547 uTm^2 14:07:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:27 Integrated Voltage Measurement... 14:07:36 Voltage Offset Correction: v_off_ini = -182.614 uV, v_off_fin = -178.457 uV 14:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.170 uVs 14:07:37 Integrated Voltage Measurement... 14:07:45 Voltage Offset Correction: v_off_ini = -175.833 uV, v_off_fin = -181.003 uV 14:07:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.206 uVs 14:07:46 Integrated Voltage Measurement... 14:07:55 Voltage Offset Correction: v_off_ini = -164.151 uV, v_off_fin = -169.426 uV 14:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.358 uVs 14:07:55 Integrated Voltage Measurement... 14:08:04 Voltage Offset Correction: v_off_ini = -170.339 uV, v_off_fin = -167.150 uV 14:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.647 uVs 14:08:04 Integrated Voltage Measurement... 14:08:13 Voltage Offset Correction: v_off_ini = -182.087 uV, v_off_fin = -171.376 uV 14:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.896 uVs 14:08:13 Integrated Voltage Measurement... 14:08:22 Voltage Offset Correction: v_off_ini = -170.414 uV, v_off_fin = -172.122 uV 14:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.102 uVs 14:08:24 I2Y Average and RMS of Measurements VT = -248.397 +- 6.270 uVs I2Y = -22.852 +- 0.577 uTm^2 14:08:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:39 Integrated Voltage Measurement... 14:08:48 Voltage Offset Correction: v_off_ini = -171.873 uV, v_off_fin = -178.729 uV 14:08:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.128 uVs 14:08:48 Integrated Voltage Measurement... 14:08:57 Voltage Offset Correction: v_off_ini = -175.447 uV, v_off_fin = -169.131 uV 14:08:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.726 uVs 14:08:58 Integrated Voltage Measurement... 14:09:06 Voltage Offset Correction: v_off_ini = -178.872 uV, v_off_fin = -183.190 uV 14:09:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.442 uVs 14:09:07 Integrated Voltage Measurement... 14:09:16 Voltage Offset Correction: v_off_ini = -172.863 uV, v_off_fin = -169.522 uV 14:09:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.044 uVs 14:09:16 Integrated Voltage Measurement... 14:09:25 Voltage Offset Correction: v_off_ini = -179.119 uV, v_off_fin = -184.710 uV 14:09:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.456 uVs 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = -161.351 uV, v_off_fin = -165.784 uV 14:09:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.058 uVs 14:09:38 I1X Average and RMS of Measurements VT = -114.642 +- 5.737 uVs I1X = 22.929 +- 1.147 uTm 14:09:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:45 Integrated Voltage Measurement... 14:09:54 Voltage Offset Correction: v_off_ini = -178.920 uV, v_off_fin = -185.206 uV 14:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.232 uVs 14:09:54 Integrated Voltage Measurement... 14:10:03 Voltage Offset Correction: v_off_ini = -174.562 uV, v_off_fin = -163.732 uV 14:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.057 uVs 14:10:03 Integrated Voltage Measurement... 14:10:12 Voltage Offset Correction: v_off_ini = -166.656 uV, v_off_fin = -180.654 uV 14:10:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.250 uVs 14:10:12 Integrated Voltage Measurement... 14:10:21 Voltage Offset Correction: v_off_ini = -169.463 uV, v_off_fin = -161.125 uV 14:10:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.973 uVs 14:10:21 Integrated Voltage Measurement... 14:10:30 Voltage Offset Correction: v_off_ini = -175.639 uV, v_off_fin = -182.892 uV 14:10:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.913 uVs 14:10:30 Integrated Voltage Measurement... 14:10:39 Voltage Offset Correction: v_off_ini = -171.519 uV, v_off_fin = -166.270 uV 14:10:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.542 uVs 14:10:43 I1Y Average and RMS of Measurements VT = -207.995 +- 1.465 uVs I1Y = -41.597 +- 0.293 uTm 14:10:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:51 Integrated Voltage Measurement... 14:11:00 Voltage Offset Correction: v_off_ini = -163.692 uV, v_off_fin = -166.980 uV 14:11:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.849 uVs 14:11:00 Integrated Voltage Measurement... 14:11:09 Voltage Offset Correction: v_off_ini = -156.023 uV, v_off_fin = -141.497 uV 14:11:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.369 uVs 14:11:09 Integrated Voltage Measurement... 14:11:18 Voltage Offset Correction: v_off_ini = -153.244 uV, v_off_fin = -165.458 uV 14:11:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.391 uVs 14:11:18 Integrated Voltage Measurement... 14:11:27 Voltage Offset Correction: v_off_ini = -159.807 uV, v_off_fin = -155.173 uV 14:11:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.972 uVs 14:11:27 Integrated Voltage Measurement... 14:11:36 Voltage Offset Correction: v_off_ini = -178.535 uV, v_off_fin = -182.407 uV 14:11:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.233 uVs 14:11:36 Integrated Voltage Measurement... 14:11:45 Voltage Offset Correction: v_off_ini = -175.179 uV, v_off_fin = -162.471 uV 14:11:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.793 uVs 14:11:47 I2X Average and RMS of Measurements VT = -107.768 +- 8.037 uVs I2X = 9.915 +- 0.740 uTm^2 14:11:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:55 Integrated Voltage Measurement... 14:12:04 Voltage Offset Correction: v_off_ini = -176.607 uV, v_off_fin = -178.961 uV 14:12:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.377 uVs 14:12:04 Integrated Voltage Measurement... 14:12:13 Voltage Offset Correction: v_off_ini = -174.198 uV, v_off_fin = -163.721 uV 14:12:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.828 uVs 14:12:13 Integrated Voltage Measurement... 14:12:22 Voltage Offset Correction: v_off_ini = -154.068 uV, v_off_fin = -164.087 uV 14:12:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.857 uVs 14:12:22 Integrated Voltage Measurement... 14:12:31 Voltage Offset Correction: v_off_ini = -164.695 uV, v_off_fin = -167.909 uV 14:12:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.747 uVs 14:12:31 Integrated Voltage Measurement... 14:12:40 Voltage Offset Correction: v_off_ini = -162.749 uV, v_off_fin = -161.950 uV 14:12:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.214 uVs 14:12:40 Integrated Voltage Measurement... 14:12:49 Voltage Offset Correction: v_off_ini = -161.239 uV, v_off_fin = -169.765 uV 14:12:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.935 uVs 14:12:52 I2Y Average and RMS of Measurements VT = -249.826 +- 4.822 uVs I2Y = -22.984 +- 0.444 uTm^2 14:13:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:07 Integrated Voltage Measurement... 14:13:16 Voltage Offset Correction: v_off_ini = -169.795 uV, v_off_fin = -160.530 uV 14:13:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.353 uVs 14:13:16 Integrated Voltage Measurement... 14:13:25 Voltage Offset Correction: v_off_ini = -158.685 uV, v_off_fin = -156.623 uV 14:13:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.524 uVs 14:13:25 Integrated Voltage Measurement... 14:13:34 Voltage Offset Correction: v_off_ini = -150.652 uV, v_off_fin = -147.385 uV 14:13:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.712 uVs 14:13:34 Integrated Voltage Measurement... 14:13:43 Voltage Offset Correction: v_off_ini = -140.827 uV, v_off_fin = -146.372 uV 14:13:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.934 uVs 14:13:43 Integrated Voltage Measurement... 14:13:52 Voltage Offset Correction: v_off_ini = -152.375 uV, v_off_fin = -174.339 uV 14:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.138 uVs 14:13:52 Integrated Voltage Measurement... 14:14:01 Voltage Offset Correction: v_off_ini = -151.227 uV, v_off_fin = -145.325 uV 14:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.483 uVs 14:14:05 I1X Average and RMS of Measurements VT = -123.691 +- 4.730 uVs I1X = 24.739 +- 0.947 uTm 14:14:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:12 Integrated Voltage Measurement... 14:14:21 Voltage Offset Correction: v_off_ini = -150.574 uV, v_off_fin = -162.797 uV 14:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.326 uVs 14:14:21 Integrated Voltage Measurement... 14:14:30 Voltage Offset Correction: v_off_ini = -147.928 uV, v_off_fin = -133.864 uV 14:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.044 uVs 14:14:30 Integrated Voltage Measurement... 14:14:39 Voltage Offset Correction: v_off_ini = -158.607 uV, v_off_fin = -177.557 uV 14:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.674 uVs 14:14:39 Integrated Voltage Measurement... 14:14:48 Voltage Offset Correction: v_off_ini = -163.829 uV, v_off_fin = -151.930 uV 14:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.109 uVs 14:14:48 Integrated Voltage Measurement... 14:14:57 Voltage Offset Correction: v_off_ini = -158.448 uV, v_off_fin = -164.296 uV 14:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.916 uVs 14:14:57 Integrated Voltage Measurement... 14:15:06 Voltage Offset Correction: v_off_ini = -152.745 uV, v_off_fin = -148.867 uV 14:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.768 uVs 14:15:10 I1Y Average and RMS of Measurements VT = -208.473 +- 2.007 uVs I1Y = -41.692 +- 0.402 uTm 14:15:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:18 Integrated Voltage Measurement... 14:15:27 Voltage Offset Correction: v_off_ini = -145.872 uV, v_off_fin = -157.537 uV 14:15:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -110.271 uVs 14:15:27 Integrated Voltage Measurement... 14:15:36 Voltage Offset Correction: v_off_ini = -142.261 uV, v_off_fin = -154.589 uV 14:15:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.910 uVs 14:15:36 Integrated Voltage Measurement... 14:15:45 Voltage Offset Correction: v_off_ini = -172.025 uV, v_off_fin = -173.229 uV 14:15:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.985 uVs 14:15:45 Integrated Voltage Measurement... 14:15:54 Voltage Offset Correction: v_off_ini = -153.659 uV, v_off_fin = -146.412 uV 14:15:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.954 uVs 14:15:54 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = -162.260 uV, v_off_fin = -170.673 uV 14:16:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.877 uVs 14:16:04 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = -138.907 uV, v_off_fin = -134.847 uV 14:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.215 uVs 14:16:15 I2X Average and RMS of Measurements VT = -106.369 +- 2.640 uVs I2X = 9.786 +- 0.243 uTm^2 14:16:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:23 Integrated Voltage Measurement... 14:16:32 Voltage Offset Correction: v_off_ini = -133.757 uV, v_off_fin = -142.531 uV 14:16:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -255.962 uVs 14:16:32 Integrated Voltage Measurement... 14:16:41 Voltage Offset Correction: v_off_ini = -134.598 uV, v_off_fin = -133.621 uV 14:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.579 uVs 14:16:41 Integrated Voltage Measurement... 14:16:50 Voltage Offset Correction: v_off_ini = -138.365 uV, v_off_fin = -142.711 uV 14:16:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.824 uVs 14:16:50 Integrated Voltage Measurement... 14:16:59 Voltage Offset Correction: v_off_ini = -139.772 uV, v_off_fin = -150.761 uV 14:16:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.489 uVs 14:16:59 Integrated Voltage Measurement... 14:17:08 Voltage Offset Correction: v_off_ini = -148.737 uV, v_off_fin = -168.437 uV 14:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.061 uVs 14:17:08 Integrated Voltage Measurement... 14:17:17 Voltage Offset Correction: v_off_ini = -146.363 uV, v_off_fin = -139.261 uV 14:17:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.218 uVs 14:17:19 I2Y Average and RMS of Measurements VT = -243.856 +- 5.699 uVs I2Y = -22.435 +- 0.525 uTm^2 14:17:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:34 Integrated Voltage Measurement... 14:17:43 Voltage Offset Correction: v_off_ini = -145.132 uV, v_off_fin = -135.118 uV 14:17:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.701 uVs 14:17:43 Integrated Voltage Measurement... 14:17:52 Voltage Offset Correction: v_off_ini = -121.939 uV, v_off_fin = -133.240 uV 14:17:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.782 uVs 14:17:52 Integrated Voltage Measurement... 14:18:01 Voltage Offset Correction: v_off_ini = -114.933 uV, v_off_fin = -137.172 uV 14:18:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.565 uVs 14:18:02 Integrated Voltage Measurement... 14:18:10 Voltage Offset Correction: v_off_ini = -132.256 uV, v_off_fin = -143.440 uV 14:18:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.666 uVs 14:18:11 Integrated Voltage Measurement... 14:18:20 Voltage Offset Correction: v_off_ini = -140.725 uV, v_off_fin = -144.142 uV 14:18:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.425 uVs 14:18:20 Integrated Voltage Measurement... 14:18:29 Voltage Offset Correction: v_off_ini = -134.817 uV, v_off_fin = -131.268 uV 14:18:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.255 uVs 14:18:33 I1X Average and RMS of Measurements VT = -133.066 +- 7.791 uVs I1X = 26.613 +- 1.558 uTm 14:18:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:40 Integrated Voltage Measurement... 14:18:49 Voltage Offset Correction: v_off_ini = -130.476 uV, v_off_fin = -131.311 uV 14:18:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.315 uVs 14:18:49 Integrated Voltage Measurement... 14:18:58 Voltage Offset Correction: v_off_ini = -120.547 uV, v_off_fin = -109.272 uV 14:18:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.496 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = -107.247 uV, v_off_fin = -127.787 uV 14:19:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.863 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = -125.861 uV, v_off_fin = -117.141 uV 14:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 210.555 uVs 14:19:16 Integrated Voltage Measurement... 14:19:25 Voltage Offset Correction: v_off_ini = -122.902 uV, v_off_fin = -130.643 uV 14:19:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -211.437 uVs 14:19:25 Integrated Voltage Measurement... 14:19:34 Voltage Offset Correction: v_off_ini = -115.274 uV, v_off_fin = -124.441 uV 14:19:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.326 uVs 14:19:38 I1Y Average and RMS of Measurements VT = -206.165 +- 6.922 uVs I1Y = -41.229 +- 1.383 uTm 14:19:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:46 Integrated Voltage Measurement... 14:19:55 Voltage Offset Correction: v_off_ini = -131.747 uV, v_off_fin = -136.328 uV 14:19:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.939 uVs 14:19:55 Integrated Voltage Measurement... 14:20:04 Voltage Offset Correction: v_off_ini = -148.222 uV, v_off_fin = -145.360 uV 14:20:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.899 uVs 14:20:04 Integrated Voltage Measurement... 14:20:13 Voltage Offset Correction: v_off_ini = -141.306 uV, v_off_fin = -149.063 uV 14:20:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.282 uVs 14:20:13 Integrated Voltage Measurement... 14:20:22 Voltage Offset Correction: v_off_ini = -127.411 uV, v_off_fin = -127.435 uV 14:20:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.059 uVs 14:20:22 Integrated Voltage Measurement... 14:20:31 Voltage Offset Correction: v_off_ini = -148.413 uV, v_off_fin = -156.672 uV 14:20:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.329 uVs 14:20:31 Integrated Voltage Measurement... 14:20:40 Voltage Offset Correction: v_off_ini = -149.135 uV, v_off_fin = -133.846 uV 14:20:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.533 uVs 14:20:42 I2X Average and RMS of Measurements VT = -114.840 +- 7.332 uVs I2X = 10.565 +- 0.674 uTm^2 14:20:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:50 Integrated Voltage Measurement... 14:20:59 Voltage Offset Correction: v_off_ini = -139.802 uV, v_off_fin = -142.725 uV 14:20:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.422 uVs 14:20:59 Integrated Voltage Measurement... 14:21:08 Voltage Offset Correction: v_off_ini = -143.170 uV, v_off_fin = -134.086 uV 14:21:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.714 uVs 14:21:08 Integrated Voltage Measurement... 14:21:17 Voltage Offset Correction: v_off_ini = -143.197 uV, v_off_fin = -143.748 uV 14:21:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.965 uVs 14:21:17 Integrated Voltage Measurement... 14:21:26 Voltage Offset Correction: v_off_ini = -146.069 uV, v_off_fin = -128.089 uV 14:21:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.522 uVs 14:21:26 Integrated Voltage Measurement... 14:21:35 Voltage Offset Correction: v_off_ini = -132.938 uV, v_off_fin = -137.286 uV 14:21:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.086 uVs 14:21:35 Integrated Voltage Measurement... 14:21:44 Voltage Offset Correction: v_off_ini = -126.220 uV, v_off_fin = -143.789 uV 14:21:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.102 uVs 14:21:47 I2Y Average and RMS of Measurements VT = -245.635 +- 6.818 uVs I2Y = -22.598 +- 0.627 uTm^2 14:21:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:02 Integrated Voltage Measurement... 14:22:11 Voltage Offset Correction: v_off_ini = -129.538 uV, v_off_fin = -137.531 uV 14:22:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.275 uVs 14:22:11 Integrated Voltage Measurement... 14:22:20 Voltage Offset Correction: v_off_ini = -138.850 uV, v_off_fin = -128.649 uV 14:22:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.069 uVs 14:22:20 Integrated Voltage Measurement... 14:22:29 Voltage Offset Correction: v_off_ini = -141.521 uV, v_off_fin = -141.290 uV 14:22:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.323 uVs 14:22:29 Integrated Voltage Measurement... 14:22:38 Voltage Offset Correction: v_off_ini = -128.460 uV, v_off_fin = -137.707 uV 14:22:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.677 uVs 14:22:38 Integrated Voltage Measurement... 14:22:47 Voltage Offset Correction: v_off_ini = -130.985 uV, v_off_fin = -143.666 uV 14:22:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.156 uVs 14:22:47 Integrated Voltage Measurement... 14:22:56 Voltage Offset Correction: v_off_ini = -125.158 uV, v_off_fin = -126.715 uV 14:22:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.903 uVs 14:23:00 I1X Average and RMS of Measurements VT = -132.234 +- 4.301 uVs I1X = 26.447 +- 0.860 uTm 14:23:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:07 Integrated Voltage Measurement... 14:23:16 Voltage Offset Correction: v_off_ini = -134.283 uV, v_off_fin = -148.422 uV 14:23:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.860 uVs 14:23:16 Integrated Voltage Measurement... 14:23:25 Voltage Offset Correction: v_off_ini = -138.325 uV, v_off_fin = -138.320 uV 14:23:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.446 uVs 14:23:25 Integrated Voltage Measurement... 14:23:34 Voltage Offset Correction: v_off_ini = -141.929 uV, v_off_fin = -151.386 uV 14:23:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.839 uVs 14:23:34 Integrated Voltage Measurement... 14:23:43 Voltage Offset Correction: v_off_ini = -149.433 uV, v_off_fin = -128.957 uV 14:23:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.353 uVs 14:23:43 Integrated Voltage Measurement... 14:23:52 Voltage Offset Correction: v_off_ini = -129.882 uV, v_off_fin = -150.470 uV 14:23:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -217.179 uVs 14:23:52 Integrated Voltage Measurement... 14:24:01 Voltage Offset Correction: v_off_ini = -136.208 uV, v_off_fin = -133.531 uV 14:24:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 208.092 uVs 14:24:05 I1Y Average and RMS of Measurements VT = -211.295 +- 9.008 uVs I1Y = -42.253 +- 1.801 uTm 14:24:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:13 Integrated Voltage Measurement... 14:24:22 Voltage Offset Correction: v_off_ini = -140.045 uV, v_off_fin = -149.878 uV 14:24:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -121.760 uVs 14:24:22 Integrated Voltage Measurement... 14:24:31 Voltage Offset Correction: v_off_ini = -149.213 uV, v_off_fin = -121.154 uV 14:24:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.339 uVs 14:24:32 Integrated Voltage Measurement... 14:24:41 Voltage Offset Correction: v_off_ini = -134.720 uV, v_off_fin = -138.667 uV 14:24:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.172 uVs 14:24:41 Integrated Voltage Measurement... 14:24:50 Voltage Offset Correction: v_off_ini = -133.295 uV, v_off_fin = -118.206 uV 14:24:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.935 uVs 14:24:50 Integrated Voltage Measurement... 14:24:59 Voltage Offset Correction: v_off_ini = -122.042 uV, v_off_fin = -129.055 uV 14:24:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.318 uVs 14:24:59 Integrated Voltage Measurement... 14:25:08 Voltage Offset Correction: v_off_ini = -129.143 uV, v_off_fin = -107.009 uV 14:25:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.391 uVs 14:25:10 I2X Average and RMS of Measurements VT = -118.153 +- 4.839 uVs I2X = 10.870 +- 0.445 uTm^2 14:25:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:18 Integrated Voltage Measurement... 14:25:27 Voltage Offset Correction: v_off_ini = -112.696 uV, v_off_fin = -124.959 uV 14:25:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.178 uVs 14:25:27 Integrated Voltage Measurement... 14:25:36 Voltage Offset Correction: v_off_ini = -115.249 uV, v_off_fin = -106.157 uV 14:25:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.450 uVs 14:25:36 Integrated Voltage Measurement... 14:25:45 Voltage Offset Correction: v_off_ini = -107.677 uV, v_off_fin = -114.068 uV 14:25:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.296 uVs 14:25:45 Integrated Voltage Measurement... 14:25:54 Voltage Offset Correction: v_off_ini = -111.518 uV, v_off_fin = -113.396 uV 14:25:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.933 uVs 14:25:54 Integrated Voltage Measurement... 14:26:03 Voltage Offset Correction: v_off_ini = -108.888 uV, v_off_fin = -109.427 uV 14:26:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.255 uVs 14:26:03 Integrated Voltage Measurement... 14:26:12 Voltage Offset Correction: v_off_ini = -103.140 uV, v_off_fin = -108.665 uV 14:26:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.873 uVs 14:26:15 I2Y Average and RMS of Measurements VT = -259.664 +- 9.355 uVs I2Y = -23.889 +- 0.861 uTm^2 14:26:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:30 Integrated Voltage Measurement... 14:26:39 Voltage Offset Correction: v_off_ini = -95.266 uV, v_off_fin = -108.872 uV 14:26:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -140.714 uVs 14:26:39 Integrated Voltage Measurement... 14:26:48 Voltage Offset Correction: v_off_ini = -100.377 uV, v_off_fin = -95.568 uV 14:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 116.787 uVs 14:26:48 Integrated Voltage Measurement... 14:26:57 Voltage Offset Correction: v_off_ini = -103.666 uV, v_off_fin = -114.133 uV 14:26:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.936 uVs 14:26:57 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = -94.104 uV, v_off_fin = -96.481 uV 14:27:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.343 uVs 14:27:06 Integrated Voltage Measurement... 14:27:15 Voltage Offset Correction: v_off_ini = -98.347 uV, v_off_fin = -111.191 uV 14:27:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -122.862 uVs 14:27:15 Integrated Voltage Measurement... 14:27:24 Voltage Offset Correction: v_off_ini = -110.741 uV, v_off_fin = -101.152 uV 14:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 111.828 uVs 14:27:28 I1X Average and RMS of Measurements VT = -122.078 +- 4.854 uVs I1X = 24.418 +- 0.971 uTm 14:27:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:35 Integrated Voltage Measurement... 14:27:44 Voltage Offset Correction: v_off_ini = -107.269 uV, v_off_fin = -109.443 uV 14:27:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -197.149 uVs 14:27:44 Integrated Voltage Measurement... 14:27:53 Voltage Offset Correction: v_off_ini = -96.860 uV, v_off_fin = -94.449 uV 14:27:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.152 uVs 14:27:53 Integrated Voltage Measurement... 14:28:02 Voltage Offset Correction: v_off_ini = -82.103 uV, v_off_fin = -108.585 uV 14:28:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.739 uVs 14:28:02 Integrated Voltage Measurement... 14:28:11 Voltage Offset Correction: v_off_ini = -102.250 uV, v_off_fin = -83.989 uV 14:28:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.472 uVs 14:28:11 Integrated Voltage Measurement... 14:28:20 Voltage Offset Correction: v_off_ini = -94.445 uV, v_off_fin = -105.656 uV 14:28:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.658 uVs 14:28:20 Integrated Voltage Measurement... 14:28:29 Voltage Offset Correction: v_off_ini = -105.389 uV, v_off_fin = -94.000 uV 14:28:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 211.146 uVs 14:28:33 I1Y Average and RMS of Measurements VT = -210.386 +- 7.048 uVs I1Y = -42.076 +- 1.408 uTm 14:28:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:41 Integrated Voltage Measurement... 14:28:50 Voltage Offset Correction: v_off_ini = -107.985 uV, v_off_fin = -110.487 uV 14:28:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.012 uVs 14:28:50 Integrated Voltage Measurement... 14:28:59 Voltage Offset Correction: v_off_ini = -104.055 uV, v_off_fin = -96.522 uV 14:28:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.173 uVs 14:28:59 Integrated Voltage Measurement... 14:29:08 Voltage Offset Correction: v_off_ini = -88.510 uV, v_off_fin = -111.423 uV 14:29:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.698 uVs 14:29:08 Integrated Voltage Measurement... 14:29:17 Voltage Offset Correction: v_off_ini = -104.034 uV, v_off_fin = -107.130 uV 14:29:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.155 uVs 14:29:17 Integrated Voltage Measurement... 14:29:26 Voltage Offset Correction: v_off_ini = -123.240 uV, v_off_fin = -130.363 uV 14:29:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.343 uVs 14:29:26 Integrated Voltage Measurement... 14:29:35 Voltage Offset Correction: v_off_ini = -128.559 uV, v_off_fin = -124.685 uV 14:29:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.495 uVs 14:29:37 I2X Average and RMS of Measurements VT = -123.813 +- 8.437 uVs I2X = 11.391 +- 0.776 uTm^2 14:29:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:45 Integrated Voltage Measurement... 14:29:54 Voltage Offset Correction: v_off_ini = -91.353 uV, v_off_fin = -100.794 uV 14:29:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -257.174 uVs 14:29:54 Integrated Voltage Measurement... 14:30:03 Voltage Offset Correction: v_off_ini = -112.371 uV, v_off_fin = -121.917 uV 14:30:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.104 uVs 14:30:03 Integrated Voltage Measurement... 14:30:12 Voltage Offset Correction: v_off_ini = -100.157 uV, v_off_fin = -99.151 uV 14:30:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.478 uVs 14:30:12 Integrated Voltage Measurement... 14:30:21 Voltage Offset Correction: v_off_ini = -106.371 uV, v_off_fin = -110.507 uV 14:30:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.192 uVs 14:30:21 Integrated Voltage Measurement... 14:30:30 Voltage Offset Correction: v_off_ini = -109.033 uV, v_off_fin = -115.033 uV 14:30:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.137 uVs 14:30:30 Integrated Voltage Measurement... 14:30:39 Voltage Offset Correction: v_off_ini = -110.558 uV, v_off_fin = -109.441 uV 14:30:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.750 uVs 14:30:42 I2Y Average and RMS of Measurements VT = -245.639 +- 4.592 uVs I2Y = -22.599 +- 0.423 uTm^2 14:30:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:57 Integrated Voltage Measurement... 14:31:06 Voltage Offset Correction: v_off_ini = -129.020 uV, v_off_fin = -123.088 uV 14:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.268 uVs 14:31:06 Integrated Voltage Measurement... 14:31:15 Voltage Offset Correction: v_off_ini = -118.105 uV, v_off_fin = -121.953 uV 14:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.019 uVs 14:31:15 Integrated Voltage Measurement... 14:31:24 Voltage Offset Correction: v_off_ini = -119.834 uV, v_off_fin = -118.414 uV 14:31:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.621 uVs 14:31:24 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = -100.159 uV, v_off_fin = -99.196 uV 14:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.291 uVs 14:31:33 Integrated Voltage Measurement... 14:31:42 Voltage Offset Correction: v_off_ini = -97.426 uV, v_off_fin = -106.433 uV 14:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.304 uVs 14:31:42 Integrated Voltage Measurement... 14:31:51 Voltage Offset Correction: v_off_ini = -100.791 uV, v_off_fin = -104.514 uV 14:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.863 uVs 14:31:55 I1X Average and RMS of Measurements VT = -136.227 +- 10.840 uVs I1X = 27.245 +- 2.168 uTm 14:31:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:02 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = -116.835 uV, v_off_fin = -131.053 uV 14:32:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.790 uVs 14:32:11 Integrated Voltage Measurement... 14:32:20 Voltage Offset Correction: v_off_ini = -129.434 uV, v_off_fin = -109.141 uV 14:32:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.877 uVs 14:32:20 Integrated Voltage Measurement... 14:32:29 Voltage Offset Correction: v_off_ini = -123.690 uV, v_off_fin = -124.362 uV 14:32:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.799 uVs 14:32:29 Integrated Voltage Measurement... 14:32:38 Voltage Offset Correction: v_off_ini = -112.574 uV, v_off_fin = -96.996 uV 14:32:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.172 uVs 14:32:38 Integrated Voltage Measurement... 14:32:47 Voltage Offset Correction: v_off_ini = -112.151 uV, v_off_fin = -122.636 uV 14:32:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.015 uVs 14:32:47 Integrated Voltage Measurement... 14:32:56 Voltage Offset Correction: v_off_ini = -109.888 uV, v_off_fin = -100.515 uV 14:32:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 199.377 uVs 14:33:00 I1Y Average and RMS of Measurements VT = -204.505 +- 3.483 uVs I1Y = -40.897 +- 0.698 uTm 14:33:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:08 Integrated Voltage Measurement... 14:33:17 Voltage Offset Correction: v_off_ini = -113.179 uV, v_off_fin = -128.303 uV 14:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.753 uVs 14:33:17 Integrated Voltage Measurement... 14:33:26 Voltage Offset Correction: v_off_ini = -105.978 uV, v_off_fin = -92.112 uV 14:33:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.106 uVs 14:33:26 Integrated Voltage Measurement... 14:33:35 Voltage Offset Correction: v_off_ini = -97.798 uV, v_off_fin = -100.744 uV 14:33:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.377 uVs 14:33:35 Integrated Voltage Measurement... 14:33:44 Voltage Offset Correction: v_off_ini = -89.787 uV, v_off_fin = -109.542 uV 14:33:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.935 uVs 14:33:44 Integrated Voltage Measurement... 14:33:53 Voltage Offset Correction: v_off_ini = -110.291 uV, v_off_fin = -121.586 uV 14:33:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.807 uVs 14:33:53 Integrated Voltage Measurement... 14:34:02 Voltage Offset Correction: v_off_ini = -117.136 uV, v_off_fin = -113.114 uV 14:34:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.434 uVs 14:34:05 I2X Average and RMS of Measurements VT = -124.069 +- 6.162 uVs I2X = 11.415 +- 0.567 uTm^2 14:34:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:13 Integrated Voltage Measurement... 14:34:22 Voltage Offset Correction: v_off_ini = -116.627 uV, v_off_fin = -114.812 uV 14:34:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.993 uVs 14:34:22 Integrated Voltage Measurement... 14:34:31 Voltage Offset Correction: v_off_ini = -127.509 uV, v_off_fin = -116.361 uV 14:34:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.797 uVs 14:34:31 Integrated Voltage Measurement... 14:34:40 Voltage Offset Correction: v_off_ini = -114.941 uV, v_off_fin = -125.845 uV 14:34:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.970 uVs 14:34:40 Integrated Voltage Measurement... 14:34:49 Voltage Offset Correction: v_off_ini = -123.636 uV, v_off_fin = -105.850 uV 14:34:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.404 uVs 14:34:49 Integrated Voltage Measurement... 14:34:58 Voltage Offset Correction: v_off_ini = -89.125 uV, v_off_fin = -96.113 uV 14:34:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.573 uVs 14:34:58 Integrated Voltage Measurement... 14:35:07 Voltage Offset Correction: v_off_ini = -126.581 uV, v_off_fin = -117.984 uV 14:35:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.273 uVs 14:35:09 I2Y Average and RMS of Measurements VT = -250.002 +- 1.781 uVs I2Y = -23.000 +- 0.164 uTm^2 14:35:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:24 Integrated Voltage Measurement... 14:35:33 Voltage Offset Correction: v_off_ini = -91.096 uV, v_off_fin = -88.607 uV 14:35:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.887 uVs 14:35:33 Integrated Voltage Measurement... 14:35:42 Voltage Offset Correction: v_off_ini = -90.180 uV, v_off_fin = -84.973 uV 14:35:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.764 uVs 14:35:42 Integrated Voltage Measurement... 14:35:51 Voltage Offset Correction: v_off_ini = -95.642 uV, v_off_fin = -89.320 uV 14:35:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.802 uVs 14:35:51 Integrated Voltage Measurement... 14:36:00 Voltage Offset Correction: v_off_ini = -101.204 uV, v_off_fin = -90.944 uV 14:36:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.950 uVs 14:36:00 Integrated Voltage Measurement... 14:36:09 Voltage Offset Correction: v_off_ini = -101.923 uV, v_off_fin = -116.006 uV 14:36:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -118.075 uVs 14:36:09 Integrated Voltage Measurement... 14:36:18 Voltage Offset Correction: v_off_ini = -123.239 uV, v_off_fin = -86.791 uV 14:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 118.867 uVs 14:36:23 I1X Average and RMS of Measurements VT = -135.391 +- 13.431 uVs I1X = 27.079 +- 2.685 uTm 14:36:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:29 Integrated Voltage Measurement... 14:36:38 Voltage Offset Correction: v_off_ini = -119.703 uV, v_off_fin = -121.665 uV 14:36:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.583 uVs 14:36:38 Integrated Voltage Measurement... 14:36:47 Voltage Offset Correction: v_off_ini = -115.696 uV, v_off_fin = -103.150 uV 14:36:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.154 uVs 14:36:47 Integrated Voltage Measurement... 14:36:56 Voltage Offset Correction: v_off_ini = -118.582 uV, v_off_fin = -126.325 uV 14:36:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.949 uVs 14:36:56 Integrated Voltage Measurement... 14:37:05 Voltage Offset Correction: v_off_ini = -112.358 uV, v_off_fin = -103.484 uV 14:37:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.409 uVs 14:37:05 Integrated Voltage Measurement... 14:37:14 Voltage Offset Correction: v_off_ini = -124.036 uV, v_off_fin = -139.566 uV 14:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.404 uVs 14:37:14 Integrated Voltage Measurement... 14:37:23 Voltage Offset Correction: v_off_ini = -109.325 uV, v_off_fin = -100.850 uV 14:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.596 uVs 14:37:28 I1Y Average and RMS of Measurements VT = -201.849 +- 3.805 uVs I1Y = -40.368 +- 0.761 uTm 14:37:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:35 Integrated Voltage Measurement... 14:37:44 Voltage Offset Correction: v_off_ini = -123.717 uV, v_off_fin = -118.505 uV 14:37:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -127.522 uVs 14:37:44 Integrated Voltage Measurement... 14:37:53 Voltage Offset Correction: v_off_ini = -119.134 uV, v_off_fin = -112.988 uV 14:37:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.221 uVs 14:37:53 Integrated Voltage Measurement... 14:38:02 Voltage Offset Correction: v_off_ini = -125.278 uV, v_off_fin = -131.564 uV 14:38:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.353 uVs 14:38:03 Integrated Voltage Measurement... 14:38:12 Voltage Offset Correction: v_off_ini = -117.821 uV, v_off_fin = -114.277 uV 14:38:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.307 uVs 14:38:12 Integrated Voltage Measurement... 14:38:21 Voltage Offset Correction: v_off_ini = -116.134 uV, v_off_fin = -126.445 uV 14:38:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.169 uVs 14:38:21 Integrated Voltage Measurement... 14:38:30 Voltage Offset Correction: v_off_ini = -102.728 uV, v_off_fin = -96.844 uV 14:38:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.449 uVs 14:38:32 I2X Average and RMS of Measurements VT = -127.837 +- 8.818 uVs I2X = 11.761 +- 0.811 uTm^2 14:38:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:40 Integrated Voltage Measurement... 14:38:49 Voltage Offset Correction: v_off_ini = -112.408 uV, v_off_fin = -112.333 uV 14:38:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.209 uVs 14:38:49 Integrated Voltage Measurement... 14:38:58 Voltage Offset Correction: v_off_ini = -107.699 uV, v_off_fin = -113.038 uV 14:38:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.919 uVs 14:38:58 Integrated Voltage Measurement... 14:39:07 Voltage Offset Correction: v_off_ini = -106.998 uV, v_off_fin = -108.824 uV 14:39:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.199 uVs 14:39:07 Integrated Voltage Measurement... 14:39:16 Voltage Offset Correction: v_off_ini = -107.423 uV, v_off_fin = -107.468 uV 14:39:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.925 uVs 14:39:16 Integrated Voltage Measurement... 14:39:25 Voltage Offset Correction: v_off_ini = -114.964 uV, v_off_fin = -119.384 uV 14:39:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.941 uVs 14:39:25 Integrated Voltage Measurement... 14:39:34 Voltage Offset Correction: v_off_ini = -91.736 uV, v_off_fin = -97.863 uV 14:39:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.797 uVs 14:39:36 I2Y Average and RMS of Measurements VT = -241.165 +- 4.348 uVs I2Y = -22.187 +- 0.400 uTm^2 14:39:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:52 Integrated Voltage Measurement... 14:40:01 Voltage Offset Correction: v_off_ini = -108.197 uV, v_off_fin = -117.513 uV 14:40:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.930 uVs 14:40:01 Integrated Voltage Measurement... 14:40:10 Voltage Offset Correction: v_off_ini = -111.693 uV, v_off_fin = -111.694 uV 14:40:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.297 uVs 14:40:10 Integrated Voltage Measurement... 14:40:19 Voltage Offset Correction: v_off_ini = -97.711 uV, v_off_fin = -98.881 uV 14:40:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.695 uVs 14:40:19 Integrated Voltage Measurement... 14:40:28 Voltage Offset Correction: v_off_ini = -101.562 uV, v_off_fin = -104.155 uV 14:40:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.006 uVs 14:40:29 Integrated Voltage Measurement... 14:40:37 Voltage Offset Correction: v_off_ini = -118.091 uV, v_off_fin = -121.109 uV 14:40:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.724 uVs 14:40:38 Integrated Voltage Measurement... 14:40:46 Voltage Offset Correction: v_off_ini = -108.502 uV, v_off_fin = -103.359 uV 14:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.191 uVs 14:40:51 I1X Average and RMS of Measurements VT = -149.474 +- 3.933 uVs I1X = 29.895 +- 0.787 uTm 14:40:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:58 Integrated Voltage Measurement... 14:41:06 Voltage Offset Correction: v_off_ini = -112.664 uV, v_off_fin = -115.164 uV 14:41:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.731 uVs 14:41:07 Integrated Voltage Measurement... 14:41:15 Voltage Offset Correction: v_off_ini = -108.100 uV, v_off_fin = -99.509 uV 14:41:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.199 uVs 14:41:16 Integrated Voltage Measurement... 14:41:24 Voltage Offset Correction: v_off_ini = -92.923 uV, v_off_fin = -111.225 uV 14:41:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.388 uVs 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = -113.588 uV, v_off_fin = -82.135 uV 14:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.957 uVs 14:41:33 Integrated Voltage Measurement... 14:41:42 Voltage Offset Correction: v_off_ini = -94.153 uV, v_off_fin = -114.552 uV 14:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.982 uVs 14:41:42 Integrated Voltage Measurement... 14:41:51 Voltage Offset Correction: v_off_ini = -102.371 uV, v_off_fin = -99.462 uV 14:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.519 uVs 14:41:56 I1Y Average and RMS of Measurements VT = -209.796 +- 4.060 uVs I1Y = -41.959 +- 0.812 uTm 14:42:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:03 Integrated Voltage Measurement... 14:42:12 Voltage Offset Correction: v_off_ini = -89.886 uV, v_off_fin = -115.928 uV 14:42:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -143.504 uVs 14:42:12 Integrated Voltage Measurement... 14:42:21 Voltage Offset Correction: v_off_ini = -104.891 uV, v_off_fin = -87.697 uV 14:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.357 uVs 14:42:21 Integrated Voltage Measurement... 14:42:30 Voltage Offset Correction: v_off_ini = -89.500 uV, v_off_fin = -100.783 uV 14:42:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.858 uVs 14:42:30 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = -89.090 uV, v_off_fin = -85.822 uV 14:42:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.439 uVs 14:42:40 Integrated Voltage Measurement... 14:42:48 Voltage Offset Correction: v_off_ini = -90.963 uV, v_off_fin = -106.947 uV 14:42:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.352 uVs 14:42:49 Integrated Voltage Measurement... 14:42:58 Voltage Offset Correction: v_off_ini = -91.583 uV, v_off_fin = -80.047 uV 14:42:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 129.284 uVs 14:43:00 I2X Average and RMS of Measurements VT = -130.132 +- 5.205 uVs I2X = 11.972 +- 0.478 uTm^2 14:43:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:08 Integrated Voltage Measurement... 14:43:17 Voltage Offset Correction: v_off_ini = -84.158 uV, v_off_fin = -103.245 uV 14:43:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.489 uVs 14:43:17 Integrated Voltage Measurement... 14:43:26 Voltage Offset Correction: v_off_ini = -83.883 uV, v_off_fin = -87.815 uV 14:43:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.715 uVs 14:43:26 Integrated Voltage Measurement... 14:43:35 Voltage Offset Correction: v_off_ini = -80.986 uV, v_off_fin = -97.494 uV 14:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.378 uVs 14:43:35 Integrated Voltage Measurement... 14:43:44 Voltage Offset Correction: v_off_ini = -88.643 uV, v_off_fin = -90.566 uV 14:43:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.412 uVs 14:43:44 Integrated Voltage Measurement... 14:43:53 Voltage Offset Correction: v_off_ini = -93.817 uV, v_off_fin = -81.222 uV 14:43:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.301 uVs 14:43:53 Integrated Voltage Measurement... 14:44:02 Voltage Offset Correction: v_off_ini = -95.844 uV, v_off_fin = -93.399 uV 14:44:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.481 uVs 14:44:04 I2Y Average and RMS of Measurements VT = -243.462 +- 3.926 uVs I2Y = -22.399 +- 0.361 uTm^2 14:44:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:20 Integrated Voltage Measurement... 14:44:29 Voltage Offset Correction: v_off_ini = -87.177 uV, v_off_fin = -83.915 uV 14:44:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.360 uVs 14:44:29 Integrated Voltage Measurement... 14:44:38 Voltage Offset Correction: v_off_ini = -84.508 uV, v_off_fin = -77.844 uV 14:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.366 uVs 14:44:38 Integrated Voltage Measurement... 14:44:47 Voltage Offset Correction: v_off_ini = -73.539 uV, v_off_fin = -86.611 uV 14:44:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.325 uVs 14:44:47 Integrated Voltage Measurement... 14:44:56 Voltage Offset Correction: v_off_ini = -59.941 uV, v_off_fin = -78.225 uV 14:44:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.001 uVs 14:44:56 Integrated Voltage Measurement... 14:45:05 Voltage Offset Correction: v_off_ini = -79.159 uV, v_off_fin = -78.515 uV 14:45:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.699 uVs 14:45:05 Integrated Voltage Measurement... 14:45:14 Voltage Offset Correction: v_off_ini = -70.753 uV, v_off_fin = -61.841 uV 14:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 116.784 uVs 14:45:19 I1X Average and RMS of Measurements VT = -143.589 +- 5.346 uVs I1X = 28.719 +- 1.068 uTm 14:45:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:25 Integrated Voltage Measurement... 14:45:34 Voltage Offset Correction: v_off_ini = -79.772 uV, v_off_fin = -85.511 uV 14:45:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -192.893 uVs 14:45:34 Integrated Voltage Measurement... 14:45:43 Voltage Offset Correction: v_off_ini = -75.204 uV, v_off_fin = -62.593 uV 14:45:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.612 uVs 14:45:43 Integrated Voltage Measurement... 14:45:52 Voltage Offset Correction: v_off_ini = -66.252 uV, v_off_fin = -87.906 uV 14:45:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -221.561 uVs 14:45:52 Integrated Voltage Measurement... 14:46:01 Voltage Offset Correction: v_off_ini = -79.009 uV, v_off_fin = -63.253 uV 14:46:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.857 uVs 14:46:01 Integrated Voltage Measurement... 14:46:10 Voltage Offset Correction: v_off_ini = -70.419 uV, v_off_fin = -86.783 uV 14:46:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.800 uVs 14:46:10 Integrated Voltage Measurement... 14:46:19 Voltage Offset Correction: v_off_ini = -63.016 uV, v_off_fin = -54.094 uV 14:46:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.884 uVs 14:46:23 I1Y Average and RMS of Measurements VT = -210.601 +- 4.909 uVs I1Y = -42.119 +- 0.979 uTm 14:46:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:31 Integrated Voltage Measurement... 14:46:40 Voltage Offset Correction: v_off_ini = -75.625 uV, v_off_fin = -71.890 uV 14:46:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.137 uVs 14:46:40 Integrated Voltage Measurement... 14:46:49 Voltage Offset Correction: v_off_ini = -64.384 uV, v_off_fin = -53.897 uV 14:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.313 uVs 14:46:49 Integrated Voltage Measurement... 14:46:58 Voltage Offset Correction: v_off_ini = -69.931 uV, v_off_fin = -67.562 uV 14:46:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.087 uVs 14:46:58 Integrated Voltage Measurement... 14:47:07 Voltage Offset Correction: v_off_ini = -53.914 uV, v_off_fin = -40.941 uV 14:47:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.754 uVs 14:47:07 Integrated Voltage Measurement... 14:47:16 Voltage Offset Correction: v_off_ini = -58.722 uV, v_off_fin = -60.917 uV 14:47:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.368 uVs 14:47:16 Integrated Voltage Measurement... 14:47:25 Voltage Offset Correction: v_off_ini = -38.094 uV, v_off_fin = -48.079 uV 14:47:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.121 uVs 14:47:28 I2X Average and RMS of Measurements VT = -120.297 +- 5.521 uVs I2X = 11.067 +- 0.508 uTm^2 14:47:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:35 Integrated Voltage Measurement... 14:47:44 Voltage Offset Correction: v_off_ini = -39.807 uV, v_off_fin = -40.249 uV 14:47:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.061 uVs 14:47:44 Integrated Voltage Measurement... 14:47:53 Voltage Offset Correction: v_off_ini = -48.484 uV, v_off_fin = -46.411 uV 14:47:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.297 uVs 14:47:54 Integrated Voltage Measurement... 14:48:03 Voltage Offset Correction: v_off_ini = -42.097 uV, v_off_fin = -42.713 uV 14:48:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.293 uVs 14:48:03 Integrated Voltage Measurement... 14:48:12 Voltage Offset Correction: v_off_ini = -43.295 uV, v_off_fin = -44.281 uV 14:48:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.697 uVs 14:48:12 Integrated Voltage Measurement... 14:48:21 Voltage Offset Correction: v_off_ini = -49.849 uV, v_off_fin = -51.615 uV 14:48:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.020 uVs 14:48:21 Integrated Voltage Measurement... 14:48:30 Voltage Offset Correction: v_off_ini = -40.843 uV, v_off_fin = -42.702 uV 14:48:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.451 uVs 14:48:32 I2Y Average and RMS of Measurements VT = -243.470 +- 7.180 uVs I2Y = -22.399 +- 0.661 uTm^2 14:48:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:50 Integrated Voltage Measurement... 14:48:59 Voltage Offset Correction: v_off_ini = -54.996 uV, v_off_fin = -47.598 uV 14:48:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.116 uVs 14:48:59 Integrated Voltage Measurement... 14:49:08 Voltage Offset Correction: v_off_ini = -35.897 uV, v_off_fin = -38.646 uV 14:49:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.285 uVs 14:49:08 Integrated Voltage Measurement... 14:49:17 Voltage Offset Correction: v_off_ini = -49.963 uV, v_off_fin = -46.377 uV 14:49:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.468 uVs 14:49:17 Integrated Voltage Measurement... 14:49:26 Voltage Offset Correction: v_off_ini = -47.050 uV, v_off_fin = -43.642 uV 14:49:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.330 uVs 14:49:26 Integrated Voltage Measurement... 14:49:35 Voltage Offset Correction: v_off_ini = -50.410 uV, v_off_fin = -48.027 uV 14:49:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.895 uVs 14:49:35 Integrated Voltage Measurement... 14:49:44 Voltage Offset Correction: v_off_ini = -43.193 uV, v_off_fin = -37.191 uV 14:49:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.517 uVs 14:49:48 I1X Average and RMS of Measurements VT = -140.268 +- 2.575 uVs I1X = 28.054 +- 0.515 uTm 14:49:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:55 Integrated Voltage Measurement... 14:50:04 Voltage Offset Correction: v_off_ini = -44.197 uV, v_off_fin = -57.833 uV 14:50:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.126 uVs 14:50:04 Integrated Voltage Measurement... 14:50:13 Voltage Offset Correction: v_off_ini = -33.393 uV, v_off_fin = -22.151 uV 14:50:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.704 uVs 14:50:13 Integrated Voltage Measurement... 14:50:22 Voltage Offset Correction: v_off_ini = -40.561 uV, v_off_fin = -45.804 uV 14:50:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.223 uVs 14:50:22 Integrated Voltage Measurement... 14:50:31 Voltage Offset Correction: v_off_ini = -41.766 uV, v_off_fin = -21.603 uV 14:50:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.828 uVs 14:50:31 Integrated Voltage Measurement... 14:50:40 Voltage Offset Correction: v_off_ini = -24.008 uV, v_off_fin = -49.206 uV 14:50:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.711 uVs 14:50:40 Integrated Voltage Measurement... 14:50:49 Voltage Offset Correction: v_off_ini = -31.152 uV, v_off_fin = -27.399 uV 14:50:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.416 uVs 14:50:53 I1Y Average and RMS of Measurements VT = -215.168 +- 0.882 uVs I1Y = -43.031 +- 0.176 uTm 14:50:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:01 Integrated Voltage Measurement... 14:51:10 Voltage Offset Correction: v_off_ini = -35.749 uV, v_off_fin = -43.771 uV 14:51:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.036 uVs 14:51:10 Integrated Voltage Measurement... 14:51:19 Voltage Offset Correction: v_off_ini = -43.149 uV, v_off_fin = -45.728 uV 14:51:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.288 uVs 14:51:19 Integrated Voltage Measurement... 14:51:28 Voltage Offset Correction: v_off_ini = -46.694 uV, v_off_fin = -39.308 uV 14:51:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -119.316 uVs 14:51:28 Integrated Voltage Measurement... 14:51:37 Voltage Offset Correction: v_off_ini = -20.335 uV, v_off_fin = -8.664 uV 14:51:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.108 uVs 14:51:37 Integrated Voltage Measurement... 14:51:46 Voltage Offset Correction: v_off_ini = -25.053 uV, v_off_fin = -36.170 uV 14:51:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -134.137 uVs 14:51:46 Integrated Voltage Measurement... 14:51:55 Voltage Offset Correction: v_off_ini = -24.883 uV, v_off_fin = -22.306 uV 14:51:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.354 uVs 14:51:58 I2X Average and RMS of Measurements VT = -129.707 +- 6.970 uVs I2X = 11.934 +- 0.641 uTm^2 14:52:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:06 Integrated Voltage Measurement... 14:52:15 Voltage Offset Correction: v_off_ini = -38.777 uV, v_off_fin = -24.038 uV 14:52:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.241 uVs 14:52:15 Integrated Voltage Measurement... 14:52:24 Voltage Offset Correction: v_off_ini = -40.506 uV, v_off_fin = -32.677 uV 14:52:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.234 uVs 14:52:24 Integrated Voltage Measurement... 14:52:33 Voltage Offset Correction: v_off_ini = -39.688 uV, v_off_fin = -38.320 uV 14:52:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.121 uVs 14:52:33 Integrated Voltage Measurement... 14:52:42 Voltage Offset Correction: v_off_ini = -29.167 uV, v_off_fin = -25.267 uV 14:52:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.723 uVs 14:52:42 Integrated Voltage Measurement... 14:52:51 Voltage Offset Correction: v_off_ini = -31.016 uV, v_off_fin = -37.463 uV 14:52:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.096 uVs 14:52:51 Integrated Voltage Measurement... 14:53:00 Voltage Offset Correction: v_off_ini = -38.240 uV, v_off_fin = -32.200 uV 14:53:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.927 uVs 14:53:02 I2Y Average and RMS of Measurements VT = -241.724 +- 2.228 uVs I2Y = -22.239 +- 0.205 uTm^2 14:53:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:20 Integrated Voltage Measurement... 14:53:29 Voltage Offset Correction: v_off_ini = -31.765 uV, v_off_fin = -43.868 uV 14:53:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.667 uVs 14:53:29 Integrated Voltage Measurement... 14:53:38 Voltage Offset Correction: v_off_ini = -33.965 uV, v_off_fin = -26.076 uV 14:53:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.391 uVs 14:53:38 Integrated Voltage Measurement... 14:53:47 Voltage Offset Correction: v_off_ini = -31.230 uV, v_off_fin = -41.223 uV 14:53:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.688 uVs 14:53:48 Integrated Voltage Measurement... 14:53:56 Voltage Offset Correction: v_off_ini = -30.436 uV, v_off_fin = -26.040 uV 14:53:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.367 uVs 14:53:57 Integrated Voltage Measurement... 14:54:05 Voltage Offset Correction: v_off_ini = -30.148 uV, v_off_fin = -31.198 uV 14:54:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.596 uVs 14:54:06 Integrated Voltage Measurement... 14:54:14 Voltage Offset Correction: v_off_ini = -36.035 uV, v_off_fin = -29.619 uV 14:54:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.290 uVs 14:54:19 I1X Average and RMS of Measurements VT = -134.833 +- 9.763 uVs I1X = 26.967 +- 1.953 uTm 14:54:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:26 Integrated Voltage Measurement... 14:54:34 Voltage Offset Correction: v_off_ini = -22.233 uV, v_off_fin = -19.611 uV 14:54:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.404 uVs 14:54:35 Integrated Voltage Measurement... 14:54:43 Voltage Offset Correction: v_off_ini = -20.161 uV, v_off_fin = -10.459 uV 14:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.127 uVs 14:54:44 Integrated Voltage Measurement... 14:54:52 Voltage Offset Correction: v_off_ini = -19.361 uV, v_off_fin = -21.163 uV 14:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.646 uVs 14:54:53 Integrated Voltage Measurement... 14:55:01 Voltage Offset Correction: v_off_ini = -27.123 uV, v_off_fin = -15.722 uV 14:55:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.609 uVs 14:55:02 Integrated Voltage Measurement... 14:55:10 Voltage Offset Correction: v_off_ini = -20.375 uV, v_off_fin = -23.588 uV 14:55:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.130 uVs 14:55:11 Integrated Voltage Measurement... 14:55:19 Voltage Offset Correction: v_off_ini = -9.359 uV, v_off_fin = -13.024 uV 14:55:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.910 uVs 14:55:24 I1Y Average and RMS of Measurements VT = -215.304 +- 1.241 uVs I1Y = -43.058 +- 0.247 uTm 14:55:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:32 Integrated Voltage Measurement... 14:55:41 Voltage Offset Correction: v_off_ini = -30.891 uV, v_off_fin = -26.718 uV 14:55:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -122.920 uVs 14:55:41 Integrated Voltage Measurement... 14:55:50 Voltage Offset Correction: v_off_ini = -30.749 uV, v_off_fin = -27.293 uV 14:55:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.994 uVs 14:55:50 Integrated Voltage Measurement... 14:55:59 Voltage Offset Correction: v_off_ini = -33.720 uV, v_off_fin = -47.997 uV 14:55:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.463 uVs 14:55:59 Integrated Voltage Measurement... 14:56:08 Voltage Offset Correction: v_off_ini = -50.683 uV, v_off_fin = -27.199 uV 14:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.413 uVs 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = -26.418 uV, v_off_fin = -37.789 uV 14:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.348 uVs 14:56:17 Integrated Voltage Measurement... 14:56:26 Voltage Offset Correction: v_off_ini = -24.587 uV, v_off_fin = 2.897 uV 14:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.698 uVs 14:56:28 I2X Average and RMS of Measurements VT = -130.139 +- 6.108 uVs I2X = 11.973 +- 0.562 uTm^2 14:56:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:36 Integrated Voltage Measurement... 14:56:45 Voltage Offset Correction: v_off_ini = -21.616 uV, v_off_fin = -14.128 uV 14:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.944 uVs 14:56:45 Integrated Voltage Measurement... 14:56:54 Voltage Offset Correction: v_off_ini = -18.127 uV, v_off_fin = -11.601 uV 14:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.024 uVs 14:56:54 Integrated Voltage Measurement... 14:57:03 Voltage Offset Correction: v_off_ini = -15.440 uV, v_off_fin = -16.112 uV 14:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.815 uVs 14:57:03 Integrated Voltage Measurement... 14:57:12 Voltage Offset Correction: v_off_ini = -8.218 uV, v_off_fin = -12.168 uV 14:57:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.705 uVs 14:57:12 Integrated Voltage Measurement... 14:57:21 Voltage Offset Correction: v_off_ini = -14.507 uV, v_off_fin = -10.909 uV 14:57:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.033 uVs 14:57:21 Integrated Voltage Measurement... 14:57:30 Voltage Offset Correction: v_off_ini = -21.622 uV, v_off_fin = -25.356 uV 14:57:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.467 uVs 14:57:32 I2Y Average and RMS of Measurements VT = -235.831 +- 9.789 uVs I2Y = -21.696 +- 0.901 uTm^2 14:57:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:51 Integrated Voltage Measurement... 14:58:00 Voltage Offset Correction: v_off_ini = -24.674 uV, v_off_fin = -30.481 uV 14:58:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.791 uVs 14:58:00 Integrated Voltage Measurement... 14:58:09 Voltage Offset Correction: v_off_ini = -28.869 uV, v_off_fin = -25.696 uV 14:58:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.902 uVs 14:58:09 Integrated Voltage Measurement... 14:58:18 Voltage Offset Correction: v_off_ini = -20.687 uV, v_off_fin = -19.402 uV 14:58:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.380 uVs 14:58:18 Integrated Voltage Measurement... 14:58:27 Voltage Offset Correction: v_off_ini = -28.046 uV, v_off_fin = -16.182 uV 14:58:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.322 uVs 14:58:27 Integrated Voltage Measurement... 14:58:36 Voltage Offset Correction: v_off_ini = -29.730 uV, v_off_fin = -32.274 uV 14:58:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.672 uVs 14:58:36 Integrated Voltage Measurement... 14:58:45 Voltage Offset Correction: v_off_ini = -23.831 uV, v_off_fin = -18.970 uV 14:58:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.422 uVs 14:58:49 I1X Average and RMS of Measurements VT = -123.915 +- 5.285 uVs I1X = 24.783 +- 1.057 uTm 14:58:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:56 Integrated Voltage Measurement... 14:59:05 Voltage Offset Correction: v_off_ini = -29.088 uV, v_off_fin = -33.390 uV 14:59:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.935 uVs 14:59:05 Integrated Voltage Measurement... 14:59:14 Voltage Offset Correction: v_off_ini = -24.251 uV, v_off_fin = -4.634 uV 14:59:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.053 uVs 14:59:14 Integrated Voltage Measurement... 14:59:23 Voltage Offset Correction: v_off_ini = -31.688 uV, v_off_fin = -35.244 uV 14:59:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.397 uVs 14:59:23 Integrated Voltage Measurement... 14:59:32 Voltage Offset Correction: v_off_ini = -33.304 uV, v_off_fin = -26.585 uV 14:59:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.934 uVs 14:59:32 Integrated Voltage Measurement... 14:59:41 Voltage Offset Correction: v_off_ini = -31.627 uV, v_off_fin = -45.301 uV 14:59:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.279 uVs 14:59:41 Integrated Voltage Measurement... 14:59:50 Voltage Offset Correction: v_off_ini = -37.001 uV, v_off_fin = -31.547 uV 14:59:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.108 uVs 14:59:54 I1Y Average and RMS of Measurements VT = -217.118 +- 4.622 uVs I1Y = -43.421 +- 0.923 uTm 14:59:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:02 Integrated Voltage Measurement... 15:00:11 Voltage Offset Correction: v_off_ini = -44.670 uV, v_off_fin = -47.519 uV 15:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.390 uVs 15:00:11 Integrated Voltage Measurement... 15:00:20 Voltage Offset Correction: v_off_ini = -28.537 uV, v_off_fin = -15.093 uV 15:00:20 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 124.557 uVs 15:00:20 Integrated Voltage Measurement... 15:00:29 Voltage Offset Correction: v_off_ini = -26.647 uV, v_off_fin = -46.947 uV 15:00:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -119.451 uVs 15:00:29 Integrated Voltage Measurement... 15:00:38 Voltage Offset Correction: v_off_ini = -39.070 uV, v_off_fin = -47.032 uV 15:00:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.391 uVs 15:00:38 Integrated Voltage Measurement... 15:00:47 Voltage Offset Correction: v_off_ini = -53.071 uV, v_off_fin = -68.122 uV 15:00:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.987 uVs 15:00:47 Integrated Voltage Measurement... 15:00:56 Voltage Offset Correction: v_off_ini = -45.926 uV, v_off_fin = -36.346 uV 15:00:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.221 uVs 15:00:58 I2X Average and RMS of Measurements VT = -113.166 +- 7.518 uVs I2X = 10.412 +- 0.692 uTm^2 15:01:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:06 Integrated Voltage Measurement... 15:01:15 Voltage Offset Correction: v_off_ini = -48.680 uV, v_off_fin = -40.938 uV 15:01:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.333 uVs 15:01:15 Integrated Voltage Measurement... 15:01:24 Voltage Offset Correction: v_off_ini = -32.448 uV, v_off_fin = -30.911 uV 15:01:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.242 uVs 15:01:24 Integrated Voltage Measurement... 15:01:33 Voltage Offset Correction: v_off_ini = -35.023 uV, v_off_fin = -35.061 uV 15:01:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.965 uVs 15:01:33 Integrated Voltage Measurement... 15:01:42 Voltage Offset Correction: v_off_ini = -22.705 uV, v_off_fin = -41.849 uV 15:01:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.549 uVs 15:01:42 Integrated Voltage Measurement... 15:01:51 Voltage Offset Correction: v_off_ini = -45.633 uV, v_off_fin = -39.659 uV 15:01:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.824 uVs 15:01:51 Integrated Voltage Measurement... 15:02:00 Voltage Offset Correction: v_off_ini = -26.776 uV, v_off_fin = -36.942 uV 15:02:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.518 uVs 15:02:03 I2Y Average and RMS of Measurements VT = -243.405 +- 3.078 uVs I2Y = -22.393 +- 0.283 uTm^2 15:02:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:21 Integrated Voltage Measurement... 15:02:30 Voltage Offset Correction: v_off_ini = -22.592 uV, v_off_fin = -36.056 uV 15:02:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.259 uVs 15:02:30 Integrated Voltage Measurement... 15:02:39 Voltage Offset Correction: v_off_ini = -33.430 uV, v_off_fin = -18.583 uV 15:02:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.785 uVs 15:02:39 Integrated Voltage Measurement... 15:02:48 Voltage Offset Correction: v_off_ini = -24.800 uV, v_off_fin = -29.131 uV 15:02:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.487 uVs 15:02:48 Integrated Voltage Measurement... 15:02:57 Voltage Offset Correction: v_off_ini = -20.216 uV, v_off_fin = -16.197 uV 15:02:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.593 uVs 15:02:57 Integrated Voltage Measurement... 15:03:06 Voltage Offset Correction: v_off_ini = -23.372 uV, v_off_fin = -14.602 uV 15:03:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.475 uVs 15:03:06 Integrated Voltage Measurement... 15:03:15 Voltage Offset Correction: v_off_ini = -8.429 uV, v_off_fin = -5.380 uV 15:03:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.835 uVs 15:03:19 I1X Average and RMS of Measurements VT = -117.739 +- 5.962 uVs I1X = 23.548 +- 1.192 uTm 15:03:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:26 Integrated Voltage Measurement... 15:03:35 Voltage Offset Correction: v_off_ini = 0.313 uV, v_off_fin = -22.192 uV 15:03:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.666 uVs 15:03:35 Integrated Voltage Measurement... 15:03:44 Voltage Offset Correction: v_off_ini = -17.287 uV, v_off_fin = -2.875 uV 15:03:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.497 uVs 15:03:44 Integrated Voltage Measurement... 15:03:53 Voltage Offset Correction: v_off_ini = 5.276 uV, v_off_fin = -6.798 uV 15:03:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.044 uVs 15:03:53 Integrated Voltage Measurement... 15:04:02 Voltage Offset Correction: v_off_ini = -2.095 uV, v_off_fin = 19.496 uV 15:04:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.801 uVs 15:04:02 Integrated Voltage Measurement... 15:04:11 Voltage Offset Correction: v_off_ini = 7.199 uV, v_off_fin = 2.501 uV 15:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.783 uVs 15:04:11 Integrated Voltage Measurement... 15:04:20 Voltage Offset Correction: v_off_ini = 12.486 uV, v_off_fin = 21.104 uV 15:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.384 uVs 15:04:24 I1Y Average and RMS of Measurements VT = -218.363 +- 1.980 uVs I1Y = -43.670 +- 0.394 uTm 15:04:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:32 Integrated Voltage Measurement... 15:04:41 Voltage Offset Correction: v_off_ini = 18.744 uV, v_off_fin = 1.216 uV 15:04:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.739 uVs 15:04:41 Integrated Voltage Measurement... 15:04:50 Voltage Offset Correction: v_off_ini = 10.665 uV, v_off_fin = 32.205 uV 15:04:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.275 uVs 15:04:50 Integrated Voltage Measurement... 15:04:59 Voltage Offset Correction: v_off_ini = 30.622 uV, v_off_fin = 18.076 uV 15:04:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.652 uVs 15:04:59 Integrated Voltage Measurement... 15:05:08 Voltage Offset Correction: v_off_ini = 27.381 uV, v_off_fin = 36.197 uV 15:05:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.909 uVs 15:05:08 Integrated Voltage Measurement... 15:05:17 Voltage Offset Correction: v_off_ini = 37.239 uV, v_off_fin = 21.576 uV 15:05:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.761 uVs 15:05:17 Integrated Voltage Measurement... 15:05:26 Voltage Offset Correction: v_off_ini = 39.063 uV, v_off_fin = 49.228 uV 15:05:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.264 uVs 15:05:28 I2X Average and RMS of Measurements VT = -118.100 +- 2.559 uVs I2X = 10.865 +- 0.235 uTm^2 15:05:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:36 Integrated Voltage Measurement... 15:05:45 Voltage Offset Correction: v_off_ini = 33.239 uV, v_off_fin = 31.775 uV 15:05:45 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -231.771 uVs 15:05:45 Integrated Voltage Measurement... 15:05:54 Voltage Offset Correction: v_off_ini = 23.391 uV, v_off_fin = 25.400 uV 15:05:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.889 uVs 15:05:54 Integrated Voltage Measurement... 15:06:03 Voltage Offset Correction: v_off_ini = 23.962 uV, v_off_fin = 28.997 uV 15:06:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.442 uVs 15:06:03 Integrated Voltage Measurement... 15:06:12 Voltage Offset Correction: v_off_ini = 26.107 uV, v_off_fin = 29.555 uV 15:06:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.141 uVs 15:06:12 Integrated Voltage Measurement... 15:06:21 Voltage Offset Correction: v_off_ini = 34.356 uV, v_off_fin = 24.247 uV 15:06:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.012 uVs 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = 25.151 uV, v_off_fin = 32.992 uV 15:06:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 238.762 uVs 15:06:33 I2Y Average and RMS of Measurements VT = -242.003 +- 7.374 uVs I2Y = -22.264 +- 0.678 uTm^2 15:06:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:51 Integrated Voltage Measurement... 15:07:00 Voltage Offset Correction: v_off_ini = 28.883 uV, v_off_fin = 16.074 uV 15:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -136.812 uVs 15:07:00 Integrated Voltage Measurement... 15:07:09 Voltage Offset Correction: v_off_ini = 14.334 uV, v_off_fin = 22.232 uV 15:07:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.515 uVs 15:07:09 Integrated Voltage Measurement... 15:07:18 Voltage Offset Correction: v_off_ini = 25.697 uV, v_off_fin = 21.324 uV 15:07:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.319 uVs 15:07:18 Integrated Voltage Measurement... 15:07:27 Voltage Offset Correction: v_off_ini = 24.708 uV, v_off_fin = 24.849 uV 15:07:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.146 uVs 15:07:27 Integrated Voltage Measurement... 15:07:36 Voltage Offset Correction: v_off_ini = 20.064 uV, v_off_fin = 8.605 uV 15:07:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.480 uVs 15:07:36 Integrated Voltage Measurement... 15:07:45 Voltage Offset Correction: v_off_ini = 20.801 uV, v_off_fin = 19.914 uV 15:07:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.686 uVs 15:07:49 I1X Average and RMS of Measurements VT = -121.993 +- 8.591 uVs I1X = 24.399 +- 1.719 uTm 15:07:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:56 Integrated Voltage Measurement... 15:08:05 Voltage Offset Correction: v_off_ini = 27.763 uV, v_off_fin = 15.788 uV 15:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.385 uVs 15:08:05 Integrated Voltage Measurement... 15:08:14 Voltage Offset Correction: v_off_ini = 13.293 uV, v_off_fin = 26.847 uV 15:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.467 uVs 15:08:14 Integrated Voltage Measurement... 15:08:23 Voltage Offset Correction: v_off_ini = 6.231 uV, v_off_fin = -9.753 uV 15:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.691 uVs 15:08:23 Integrated Voltage Measurement... 15:08:32 Voltage Offset Correction: v_off_ini = 16.399 uV, v_off_fin = 24.282 uV 15:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.495 uVs 15:08:32 Integrated Voltage Measurement... 15:08:41 Voltage Offset Correction: v_off_ini = 5.365 uV, v_off_fin = -6.360 uV 15:08:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.145 uVs 15:08:41 Integrated Voltage Measurement... 15:08:50 Voltage Offset Correction: v_off_ini = 7.771 uV, v_off_fin = 25.054 uV 15:08:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.199 uVs 15:08:55 I1Y Average and RMS of Measurements VT = -219.897 +- 5.517 uVs I1Y = -43.978 +- 1.104 uTm 15:09:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:02 Integrated Voltage Measurement... 15:09:11 Voltage Offset Correction: v_off_ini = 15.720 uV, v_off_fin = 7.973 uV 15:09:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -132.125 uVs 15:09:11 Integrated Voltage Measurement... 15:09:20 Voltage Offset Correction: v_off_ini = 9.071 uV, v_off_fin = 29.914 uV 15:09:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.449 uVs 15:09:20 Integrated Voltage Measurement... 15:09:29 Voltage Offset Correction: v_off_ini = 29.035 uV, v_off_fin = 20.505 uV 15:09:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.628 uVs 15:09:29 Integrated Voltage Measurement... 15:09:38 Voltage Offset Correction: v_off_ini = 17.984 uV, v_off_fin = 44.142 uV 15:09:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.212 uVs 15:09:39 Integrated Voltage Measurement... 15:09:48 Voltage Offset Correction: v_off_ini = 21.423 uV, v_off_fin = 17.552 uV 15:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.350 uVs 15:09:48 Integrated Voltage Measurement... 15:09:57 Voltage Offset Correction: v_off_ini = 24.609 uV, v_off_fin = 23.943 uV 15:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.249 uVs 15:09:59 I2X Average and RMS of Measurements VT = -107.669 +- 9.826 uVs I2X = 9.905 +- 0.904 uTm^2 15:10:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:07 Integrated Voltage Measurement... 15:10:16 Voltage Offset Correction: v_off_ini = 3.014 uV, v_off_fin = -2.606 uV 15:10:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.771 uVs 15:10:16 Integrated Voltage Measurement... 15:10:25 Voltage Offset Correction: v_off_ini = 25.301 uV, v_off_fin = 10.167 uV 15:10:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.323 uVs 15:10:25 Integrated Voltage Measurement... 15:10:34 Voltage Offset Correction: v_off_ini = 14.297 uV, v_off_fin = -8.992 uV 15:10:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.175 uVs 15:10:34 Integrated Voltage Measurement... 15:10:43 Voltage Offset Correction: v_off_ini = 4.807 uV, v_off_fin = 15.428 uV 15:10:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.547 uVs 15:10:43 Integrated Voltage Measurement... 15:10:52 Voltage Offset Correction: v_off_ini = 18.310 uV, v_off_fin = 20.780 uV 15:10:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.775 uVs 15:10:52 Integrated Voltage Measurement... 15:11:01 Voltage Offset Correction: v_off_ini = 8.188 uV, v_off_fin = 20.926 uV 15:11:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.505 uVs 15:11:03 I2Y Average and RMS of Measurements VT = -240.349 +- 1.710 uVs I2Y = -22.112 +- 0.157 uTm^2 15:11:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:22 Integrated Voltage Measurement... 15:11:31 Voltage Offset Correction: v_off_ini = 25.679 uV, v_off_fin = 21.709 uV 15:11:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.815 uVs 15:11:31 Integrated Voltage Measurement... 15:11:40 Voltage Offset Correction: v_off_ini = 24.646 uV, v_off_fin = 34.569 uV 15:11:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.278 uVs 15:11:40 Integrated Voltage Measurement... 15:11:49 Voltage Offset Correction: v_off_ini = 14.613 uV, v_off_fin = 26.574 uV 15:11:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.339 uVs 15:11:49 Integrated Voltage Measurement... 15:11:58 Voltage Offset Correction: v_off_ini = 25.522 uV, v_off_fin = 23.850 uV 15:11:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.008 uVs 15:11:58 Integrated Voltage Measurement... 15:12:07 Voltage Offset Correction: v_off_ini = 20.967 uV, v_off_fin = 27.204 uV 15:12:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.128 uVs 15:12:07 Integrated Voltage Measurement... 15:12:16 Voltage Offset Correction: v_off_ini = 38.469 uV, v_off_fin = 38.383 uV 15:12:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.846 uVs 15:12:20 I1X Average and RMS of Measurements VT = -108.735 +- 4.164 uVs I1X = 21.748 +- 0.833 uTm 15:12:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:27 Integrated Voltage Measurement... 15:12:36 Voltage Offset Correction: v_off_ini = 33.624 uV, v_off_fin = 26.013 uV 15:12:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.084 uVs 15:12:36 Integrated Voltage Measurement... 15:12:45 Voltage Offset Correction: v_off_ini = 39.462 uV, v_off_fin = 49.237 uV 15:12:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.424 uVs 15:12:45 Integrated Voltage Measurement... 15:12:54 Voltage Offset Correction: v_off_ini = 43.475 uV, v_off_fin = 21.402 uV 15:12:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.606 uVs 15:12:54 Integrated Voltage Measurement... 15:13:03 Voltage Offset Correction: v_off_ini = 29.035 uV, v_off_fin = 40.643 uV 15:13:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.226 uVs 15:13:03 Integrated Voltage Measurement... 15:13:12 Voltage Offset Correction: v_off_ini = 10.191 uV, v_off_fin = 7.666 uV 15:13:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -222.492 uVs 15:13:12 Integrated Voltage Measurement... 15:13:21 Voltage Offset Correction: v_off_ini = 23.627 uV, v_off_fin = 36.549 uV 15:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.424 uVs 15:13:25 I1Y Average and RMS of Measurements VT = -222.376 +- 3.417 uVs I1Y = -44.473 +- 0.682 uTm 15:13:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:33 Integrated Voltage Measurement... 15:13:42 Voltage Offset Correction: v_off_ini = 18.811 uV, v_off_fin = 26.806 uV 15:13:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -96.600 uVs 15:13:42 Integrated Voltage Measurement... 15:13:51 Voltage Offset Correction: v_off_ini = 32.269 uV, v_off_fin = 40.481 uV 15:13:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.246 uVs 15:13:51 Integrated Voltage Measurement... 15:14:00 Voltage Offset Correction: v_off_ini = 17.742 uV, v_off_fin = 19.412 uV 15:14:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.080 uVs 15:14:00 Integrated Voltage Measurement... 15:14:09 Voltage Offset Correction: v_off_ini = 38.725 uV, v_off_fin = 38.572 uV 15:14:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.689 uVs 15:14:09 Integrated Voltage Measurement... 15:14:18 Voltage Offset Correction: v_off_ini = 29.668 uV, v_off_fin = 23.003 uV 15:14:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.814 uVs 15:14:18 Integrated Voltage Measurement... 15:14:27 Voltage Offset Correction: v_off_ini = 28.297 uV, v_off_fin = 42.806 uV 15:14:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.401 uVs 15:14:30 I2X Average and RMS of Measurements VT = -91.472 +- 7.607 uVs I2X = 8.415 +- 0.700 uTm^2 15:14:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:37 Integrated Voltage Measurement... 15:14:46 Voltage Offset Correction: v_off_ini = 18.987 uV, v_off_fin = 21.880 uV 15:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.367 uVs 15:14:47 Integrated Voltage Measurement... 15:14:56 Voltage Offset Correction: v_off_ini = 17.764 uV, v_off_fin = 19.660 uV 15:14:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 243.529 uVs 15:14:56 Integrated Voltage Measurement... 15:15:05 Voltage Offset Correction: v_off_ini = 29.876 uV, v_off_fin = 18.835 uV 15:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.824 uVs 15:15:05 Integrated Voltage Measurement... 15:15:14 Voltage Offset Correction: v_off_ini = 21.444 uV, v_off_fin = 18.328 uV 15:15:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.321 uVs 15:15:14 Integrated Voltage Measurement... 15:15:23 Voltage Offset Correction: v_off_ini = 20.997 uV, v_off_fin = 11.685 uV 15:15:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.073 uVs 15:15:23 Integrated Voltage Measurement... 15:15:32 Voltage Offset Correction: v_off_ini = 18.867 uV, v_off_fin = 6.742 uV 15:15:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.501 uVs 15:15:34 I2Y Average and RMS of Measurements VT = -239.436 +- 0.806 uVs I2Y = -22.028 +- 0.074 uTm^2 15:15:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm