SLAC Magnetic Measurements Date: 09-03-2025 Time: 15:19:07 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16340 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 15:19:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:17 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:19:19 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:19:20 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:19:22 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:19:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:20:03 Integrated Voltage Measurement... 15:20:12 Voltage Offset Correction: v_off_ini = 3.833 uV, v_off_fin = -11.158 uV 15:20:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.822 uVs 15:20:12 Integrated Voltage Measurement... 15:20:21 Voltage Offset Correction: v_off_ini = -9.167 uV, v_off_fin = -29.557 uV 15:20:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.745 uVs 15:20:21 Integrated Voltage Measurement... 15:20:30 Voltage Offset Correction: v_off_ini = -19.232 uV, v_off_fin = -31.101 uV 15:20:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.120 uVs 15:20:30 Integrated Voltage Measurement... 15:20:39 Voltage Offset Correction: v_off_ini = -15.625 uV, v_off_fin = -24.290 uV 15:20:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.794 uVs 15:20:39 Integrated Voltage Measurement... 15:20:48 Voltage Offset Correction: v_off_ini = -21.760 uV, v_off_fin = -24.342 uV 15:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.871 uVs 15:20:48 Integrated Voltage Measurement... 15:20:57 Voltage Offset Correction: v_off_ini = -17.760 uV, v_off_fin = -11.110 uV 15:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.558 uVs 15:21:01 I1X Average and RMS of Measurements VT = -90.818 +- 4.869 uVs I1X = 18.164 +- 0.974 uTm 15:21:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:21:08 Integrated Voltage Measurement... 15:21:17 Voltage Offset Correction: v_off_ini = -18.950 uV, v_off_fin = -18.479 uV 15:21:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.613 uVs 15:21:17 Integrated Voltage Measurement... 15:21:26 Voltage Offset Correction: v_off_ini = -2.190 uV, v_off_fin = 5.367 uV 15:21:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.836 uVs 15:21:26 Integrated Voltage Measurement... 15:21:35 Voltage Offset Correction: v_off_ini = -6.090 uV, v_off_fin = -6.468 uV 15:21:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.018 uVs 15:21:35 Integrated Voltage Measurement... 15:21:44 Voltage Offset Correction: v_off_ini = 16.083 uV, v_off_fin = 15.411 uV 15:21:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.508 uVs 15:21:44 Integrated Voltage Measurement... 15:21:53 Voltage Offset Correction: v_off_ini = -11.890 uV, v_off_fin = -29.076 uV 15:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.308 uVs 15:21:53 Integrated Voltage Measurement... 15:22:02 Voltage Offset Correction: v_off_ini = -18.024 uV, v_off_fin = 1.485 uV 15:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.524 uVs 15:22:06 I1Y Average and RMS of Measurements VT = -159.134 +- 4.024 uVs I1Y = -31.827 +- 0.805 uTm 15:22:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:22:14 Integrated Voltage Measurement... 15:22:23 Voltage Offset Correction: v_off_ini = -15.163 uV, v_off_fin = -26.015 uV 15:22:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -77.052 uVs 15:22:23 Integrated Voltage Measurement... 15:22:32 Voltage Offset Correction: v_off_ini = -9.542 uV, v_off_fin = -14.355 uV 15:22:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.678 uVs 15:22:32 Integrated Voltage Measurement... 15:22:41 Voltage Offset Correction: v_off_ini = -20.500 uV, v_off_fin = -29.100 uV 15:22:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.672 uVs 15:22:41 Integrated Voltage Measurement... 15:22:50 Voltage Offset Correction: v_off_ini = -26.766 uV, v_off_fin = -10.694 uV 15:22:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.584 uVs 15:22:50 Integrated Voltage Measurement... 15:22:59 Voltage Offset Correction: v_off_ini = -21.127 uV, v_off_fin = -29.170 uV 15:22:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.401 uVs 15:22:59 Integrated Voltage Measurement... 15:23:08 Voltage Offset Correction: v_off_ini = -22.538 uV, v_off_fin = -10.417 uV 15:23:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.827 uVs 15:23:11 I2X Average and RMS of Measurements VT = -60.369 +- 3.280 uVs I2X = 5.554 +- 0.302 uTm^2 15:23:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:23:18 Integrated Voltage Measurement... 15:23:27 Voltage Offset Correction: v_off_ini = -10.594 uV, v_off_fin = -13.360 uV 15:23:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.376 uVs 15:23:27 Integrated Voltage Measurement... 15:23:36 Voltage Offset Correction: v_off_ini = -18.239 uV, v_off_fin = -21.003 uV 15:23:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.420 uVs 15:23:37 Integrated Voltage Measurement... 15:23:46 Voltage Offset Correction: v_off_ini = -26.802 uV, v_off_fin = -12.790 uV 15:23:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.325 uVs 15:23:46 Integrated Voltage Measurement... 15:23:55 Voltage Offset Correction: v_off_ini = -5.456 uV, v_off_fin = -14.403 uV 15:23:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.909 uVs 15:23:55 Integrated Voltage Measurement... 15:24:04 Voltage Offset Correction: v_off_ini = -12.002 uV, v_off_fin = -3.385 uV 15:24:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.043 uVs 15:24:04 Integrated Voltage Measurement... 15:24:13 Voltage Offset Correction: v_off_ini = -5.587 uV, v_off_fin = -12.209 uV 15:24:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.142 uVs 15:24:15 I2Y Average and RMS of Measurements VT = -205.702 +- 3.756 uVs I2Y = -18.925 +- 0.346 uTm^2 15:24:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:24:24 Integrated Voltage Measurement... 15:24:33 Voltage Offset Correction: v_off_ini = -2.324 uV, v_off_fin = -9.476 uV 15:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.435 uVs 15:24:33 Integrated Voltage Measurement... 15:24:42 Voltage Offset Correction: v_off_ini = 14.773 uV, v_off_fin = 15.942 uV 15:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.099 uVs 15:24:42 Integrated Voltage Measurement... 15:24:51 Voltage Offset Correction: v_off_ini = 24.057 uV, v_off_fin = 15.444 uV 15:24:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.009 uVs 15:24:51 Integrated Voltage Measurement... 15:25:00 Voltage Offset Correction: v_off_ini = 14.618 uV, v_off_fin = 25.599 uV 15:25:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.637 uVs 15:25:00 Integrated Voltage Measurement... 15:25:09 Voltage Offset Correction: v_off_ini = 2.463 uV, v_off_fin = 5.890 uV 15:25:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.029 uVs 15:25:09 Integrated Voltage Measurement... 15:25:18 Voltage Offset Correction: v_off_ini = 21.118 uV, v_off_fin = 20.196 uV 15:25:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.129 uVs 15:25:22 I1X Average and RMS of Measurements VT = -84.056 +- 5.224 uVs I1X = 16.811 +- 1.045 uTm 15:25:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:25:29 Integrated Voltage Measurement... 15:25:38 Voltage Offset Correction: v_off_ini = 11.365 uV, v_off_fin = 12.071 uV 15:25:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.159 uVs 15:25:38 Integrated Voltage Measurement... 15:25:47 Voltage Offset Correction: v_off_ini = 21.539 uV, v_off_fin = 33.120 uV 15:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.572 uVs 15:25:47 Integrated Voltage Measurement... 15:25:56 Voltage Offset Correction: v_off_ini = 34.260 uV, v_off_fin = 16.621 uV 15:25:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.533 uVs 15:25:56 Integrated Voltage Measurement... 15:26:05 Voltage Offset Correction: v_off_ini = 25.869 uV, v_off_fin = 44.510 uV 15:26:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.532 uVs 15:26:05 Integrated Voltage Measurement... 15:26:14 Voltage Offset Correction: v_off_ini = 29.657 uV, v_off_fin = 21.144 uV 15:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.639 uVs 15:26:14 Integrated Voltage Measurement... 15:26:23 Voltage Offset Correction: v_off_ini = 30.750 uV, v_off_fin = 44.835 uV 15:26:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.248 uVs 15:26:28 I1Y Average and RMS of Measurements VT = -187.114 +- 1.878 uVs I1Y = -37.423 +- 0.375 uTm 15:26:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:26:35 Integrated Voltage Measurement... 15:26:44 Voltage Offset Correction: v_off_ini = 32.731 uV, v_off_fin = 30.125 uV 15:26:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -69.887 uVs 15:26:44 Integrated Voltage Measurement... 15:26:53 Voltage Offset Correction: v_off_ini = 29.084 uV, v_off_fin = 37.464 uV 15:26:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.194 uVs 15:26:54 Integrated Voltage Measurement... 15:27:03 Voltage Offset Correction: v_off_ini = 31.818 uV, v_off_fin = 30.343 uV 15:27:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.655 uVs 15:27:03 Integrated Voltage Measurement... 15:27:12 Voltage Offset Correction: v_off_ini = 29.585 uV, v_off_fin = 43.899 uV 15:27:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.463 uVs 15:27:12 Integrated Voltage Measurement... 15:27:21 Voltage Offset Correction: v_off_ini = 31.185 uV, v_off_fin = 26.124 uV 15:27:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.568 uVs 15:27:21 Integrated Voltage Measurement... 15:27:30 Voltage Offset Correction: v_off_ini = 38.834 uV, v_off_fin = 38.715 uV 15:27:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.605 uVs 15:27:32 I2X Average and RMS of Measurements VT = -66.562 +- 4.024 uVs I2X = 6.124 +- 0.370 uTm^2 15:27:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:27:40 Integrated Voltage Measurement... 15:27:49 Voltage Offset Correction: v_off_ini = 23.878 uV, v_off_fin = 17.165 uV 15:27:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.153 uVs 15:27:49 Integrated Voltage Measurement... 15:27:58 Voltage Offset Correction: v_off_ini = 28.881 uV, v_off_fin = 32.567 uV 15:27:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.467 uVs 15:27:58 Integrated Voltage Measurement... 15:28:07 Voltage Offset Correction: v_off_ini = 26.560 uV, v_off_fin = 20.102 uV 15:28:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.433 uVs 15:28:07 Integrated Voltage Measurement... 15:28:16 Voltage Offset Correction: v_off_ini = 25.958 uV, v_off_fin = 31.890 uV 15:28:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.294 uVs 15:28:16 Integrated Voltage Measurement... 15:28:25 Voltage Offset Correction: v_off_ini = 26.892 uV, v_off_fin = 31.514 uV 15:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.734 uVs 15:28:25 Integrated Voltage Measurement... 15:28:34 Voltage Offset Correction: v_off_ini = 35.325 uV, v_off_fin = 38.317 uV 15:28:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.217 uVs 15:28:37 I2Y Average and RMS of Measurements VT = -240.883 +- 8.515 uVs I2Y = -22.161 +- 0.783 uTm^2 15:28:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:46 Integrated Voltage Measurement... 15:28:55 Voltage Offset Correction: v_off_ini = 30.171 uV, v_off_fin = 29.415 uV 15:28:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.643 uVs 15:28:55 Integrated Voltage Measurement... 15:29:04 Voltage Offset Correction: v_off_ini = 19.267 uV, v_off_fin = 34.059 uV 15:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.056 uVs 15:29:04 Integrated Voltage Measurement... 15:29:13 Voltage Offset Correction: v_off_ini = 17.894 uV, v_off_fin = 12.163 uV 15:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.971 uVs 15:29:13 Integrated Voltage Measurement... 15:29:22 Voltage Offset Correction: v_off_ini = 23.998 uV, v_off_fin = 31.156 uV 15:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.487 uVs 15:29:22 Integrated Voltage Measurement... 15:29:31 Voltage Offset Correction: v_off_ini = 26.242 uV, v_off_fin = 25.598 uV 15:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.216 uVs 15:29:31 Integrated Voltage Measurement... 15:29:40 Voltage Offset Correction: v_off_ini = 17.563 uV, v_off_fin = 16.663 uV 15:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.712 uVs 15:29:44 I1X Average and RMS of Measurements VT = -81.347 +- 10.129 uVs I1X = 16.269 +- 2.026 uTm 15:29:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:51 Integrated Voltage Measurement... 15:30:00 Voltage Offset Correction: v_off_ini = 16.934 uV, v_off_fin = 16.078 uV 15:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.682 uVs 15:30:00 Integrated Voltage Measurement... 15:30:09 Voltage Offset Correction: v_off_ini = 25.488 uV, v_off_fin = 23.048 uV 15:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.990 uVs 15:30:09 Integrated Voltage Measurement... 15:30:18 Voltage Offset Correction: v_off_ini = 11.844 uV, v_off_fin = 7.808 uV 15:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.960 uVs 15:30:18 Integrated Voltage Measurement... 15:30:27 Voltage Offset Correction: v_off_ini = 4.350 uV, v_off_fin = 21.863 uV 15:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.881 uVs 15:30:27 Integrated Voltage Measurement... 15:30:36 Voltage Offset Correction: v_off_ini = 6.926 uV, v_off_fin = 2.312 uV 15:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.986 uVs 15:30:36 Integrated Voltage Measurement... 15:30:45 Voltage Offset Correction: v_off_ini = 12.946 uV, v_off_fin = 25.916 uV 15:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.916 uVs 15:30:49 I1Y Average and RMS of Measurements VT = -199.236 +- 2.436 uVs I1Y = -39.847 +- 0.487 uTm 15:30:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:57 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = 12.961 uV, v_off_fin = 10.837 uV 15:31:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -60.686 uVs 15:31:06 Integrated Voltage Measurement... 15:31:15 Voltage Offset Correction: v_off_ini = 23.650 uV, v_off_fin = 25.755 uV 15:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.650 uVs 15:31:15 Integrated Voltage Measurement... 15:31:24 Voltage Offset Correction: v_off_ini = 26.442 uV, v_off_fin = 25.675 uV 15:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.303 uVs 15:31:24 Integrated Voltage Measurement... 15:31:33 Voltage Offset Correction: v_off_ini = 29.285 uV, v_off_fin = 41.198 uV 15:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.093 uVs 15:31:33 Integrated Voltage Measurement... 15:31:42 Voltage Offset Correction: v_off_ini = 30.795 uV, v_off_fin = 5.591 uV 15:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.540 uVs 15:31:42 Integrated Voltage Measurement... 15:31:51 Voltage Offset Correction: v_off_ini = 30.575 uV, v_off_fin = 45.969 uV 15:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.529 uVs 15:31:54 I2X Average and RMS of Measurements VT = -63.300 +- 3.276 uVs I2X = 5.824 +- 0.302 uTm^2 15:31:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:01 Integrated Voltage Measurement... 15:32:10 Voltage Offset Correction: v_off_ini = 54.086 uV, v_off_fin = 51.241 uV 15:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.211 uVs 15:32:10 Integrated Voltage Measurement... 15:32:19 Voltage Offset Correction: v_off_ini = 50.629 uV, v_off_fin = 42.548 uV 15:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.222 uVs 15:32:19 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = 54.142 uV, v_off_fin = 42.735 uV 15:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.533 uVs 15:32:28 Integrated Voltage Measurement... 15:32:37 Voltage Offset Correction: v_off_ini = 41.104 uV, v_off_fin = 48.275 uV 15:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.939 uVs 15:32:37 Integrated Voltage Measurement... 15:32:46 Voltage Offset Correction: v_off_ini = 31.570 uV, v_off_fin = 33.486 uV 15:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.033 uVs 15:32:46 Integrated Voltage Measurement... 15:32:55 Voltage Offset Correction: v_off_ini = 28.474 uV, v_off_fin = 24.674 uV 15:32:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.539 uVs 15:32:58 I2Y Average and RMS of Measurements VT = -260.413 +- 2.696 uVs I2Y = -23.958 +- 0.248 uTm^2 15:33:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:33:07 Integrated Voltage Measurement... 15:33:16 Voltage Offset Correction: v_off_ini = 43.467 uV, v_off_fin = 42.062 uV 15:33:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.472 uVs 15:33:16 Integrated Voltage Measurement... 15:33:25 Voltage Offset Correction: v_off_ini = 26.756 uV, v_off_fin = 36.525 uV 15:33:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.050 uVs 15:33:25 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = 40.802 uV, v_off_fin = 37.174 uV 15:33:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.552 uVs 15:33:34 Integrated Voltage Measurement... 15:33:43 Voltage Offset Correction: v_off_ini = 39.751 uV, v_off_fin = 44.915 uV 15:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.163 uVs 15:33:43 Integrated Voltage Measurement... 15:33:52 Voltage Offset Correction: v_off_ini = 43.954 uV, v_off_fin = 37.265 uV 15:33:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.997 uVs 15:33:52 Integrated Voltage Measurement... 15:34:01 Voltage Offset Correction: v_off_ini = 22.307 uV, v_off_fin = 33.730 uV 15:34:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.033 uVs 15:34:05 I1X Average and RMS of Measurements VT = -91.211 +- 4.276 uVs I1X = 18.242 +- 0.855 uTm 15:34:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:34:12 Integrated Voltage Measurement... 15:34:21 Voltage Offset Correction: v_off_ini = 20.830 uV, v_off_fin = 17.372 uV 15:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -226.877 uVs 15:34:21 Integrated Voltage Measurement... 15:34:30 Voltage Offset Correction: v_off_ini = 25.455 uV, v_off_fin = 36.683 uV 15:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.119 uVs 15:34:30 Integrated Voltage Measurement... 15:34:39 Voltage Offset Correction: v_off_ini = 24.520 uV, v_off_fin = 9.254 uV 15:34:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.846 uVs 15:34:39 Integrated Voltage Measurement... 15:34:48 Voltage Offset Correction: v_off_ini = 39.852 uV, v_off_fin = 56.866 uV 15:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.571 uVs 15:34:48 Integrated Voltage Measurement... 15:34:57 Voltage Offset Correction: v_off_ini = 32.816 uV, v_off_fin = 28.245 uV 15:34:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.842 uVs 15:34:57 Integrated Voltage Measurement... 15:35:06 Voltage Offset Correction: v_off_ini = 28.704 uV, v_off_fin = 34.465 uV 15:35:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.385 uVs 15:35:10 I1Y Average and RMS of Measurements VT = -229.273 +- 3.642 uVs I1Y = -45.855 +- 0.729 uTm 15:35:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:35:18 Integrated Voltage Measurement... 15:35:27 Voltage Offset Correction: v_off_ini = 28.444 uV, v_off_fin = 32.416 uV 15:35:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -59.828 uVs 15:35:27 Integrated Voltage Measurement... 15:35:36 Voltage Offset Correction: v_off_ini = 30.783 uV, v_off_fin = 39.271 uV 15:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.898 uVs 15:35:36 Integrated Voltage Measurement... 15:35:45 Voltage Offset Correction: v_off_ini = 33.981 uV, v_off_fin = 24.342 uV 15:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.702 uVs 15:35:45 Integrated Voltage Measurement... 15:35:54 Voltage Offset Correction: v_off_ini = 20.171 uV, v_off_fin = 45.846 uV 15:35:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.277 uVs 15:35:54 Integrated Voltage Measurement... 15:36:03 Voltage Offset Correction: v_off_ini = 36.795 uV, v_off_fin = 22.079 uV 15:36:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.644 uVs 15:36:03 Integrated Voltage Measurement... 15:36:12 Voltage Offset Correction: v_off_ini = 33.568 uV, v_off_fin = 50.938 uV 15:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.140 uVs 15:36:14 I2X Average and RMS of Measurements VT = -59.081 +- 0.896 uVs I2X = 5.435 +- 0.083 uTm^2 15:36:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:36:22 Integrated Voltage Measurement... 15:36:31 Voltage Offset Correction: v_off_ini = 38.830 uV, v_off_fin = 30.222 uV 15:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.949 uVs 15:36:31 Integrated Voltage Measurement... 15:36:40 Voltage Offset Correction: v_off_ini = 32.813 uV, v_off_fin = 34.575 uV 15:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.885 uVs 15:36:40 Integrated Voltage Measurement... 15:36:49 Voltage Offset Correction: v_off_ini = 34.671 uV, v_off_fin = 36.312 uV 15:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.008 uVs 15:36:49 Integrated Voltage Measurement... 15:36:58 Voltage Offset Correction: v_off_ini = 51.659 uV, v_off_fin = 40.653 uV 15:36:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.592 uVs 15:36:58 Integrated Voltage Measurement... 15:37:07 Voltage Offset Correction: v_off_ini = 58.584 uV, v_off_fin = 53.939 uV 15:37:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.881 uVs 15:37:07 Integrated Voltage Measurement... 15:37:16 Voltage Offset Correction: v_off_ini = 55.891 uV, v_off_fin = 53.555 uV 15:37:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.649 uVs 15:37:19 I2Y Average and RMS of Measurements VT = -290.994 +- 5.837 uVs I2Y = -26.771 +- 0.537 uTm^2 15:37:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:37:27 Integrated Voltage Measurement... 15:37:36 Voltage Offset Correction: v_off_ini = 53.584 uV, v_off_fin = 55.058 uV 15:37:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.760 uVs 15:37:36 Integrated Voltage Measurement... 15:37:45 Voltage Offset Correction: v_off_ini = 76.127 uV, v_off_fin = 63.836 uV 15:37:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.036 uVs 15:37:45 Integrated Voltage Measurement... 15:37:54 Voltage Offset Correction: v_off_ini = 38.587 uV, v_off_fin = 48.030 uV 15:37:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.467 uVs 15:37:54 Integrated Voltage Measurement... 15:38:03 Voltage Offset Correction: v_off_ini = 58.073 uV, v_off_fin = 51.561 uV 15:38:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.956 uVs 15:38:04 Integrated Voltage Measurement... 15:38:13 Voltage Offset Correction: v_off_ini = 50.721 uV, v_off_fin = 46.398 uV 15:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.779 uVs 15:38:13 Integrated Voltage Measurement... 15:38:22 Voltage Offset Correction: v_off_ini = 40.285 uV, v_off_fin = 47.139 uV 15:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.368 uVs 15:38:26 I1X Average and RMS of Measurements VT = -80.394 +- 8.507 uVs I1X = 16.079 +- 1.701 uTm 15:38:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:38:33 Integrated Voltage Measurement... 15:38:42 Voltage Offset Correction: v_off_ini = 52.579 uV, v_off_fin = 44.049 uV 15:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.114 uVs 15:38:42 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = 32.169 uV, v_off_fin = 46.580 uV 15:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.365 uVs 15:38:51 Integrated Voltage Measurement... 15:39:00 Voltage Offset Correction: v_off_ini = 44.463 uV, v_off_fin = 32.503 uV 15:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.518 uVs 15:39:00 Integrated Voltage Measurement... 15:39:09 Voltage Offset Correction: v_off_ini = 20.404 uV, v_off_fin = 43.227 uV 15:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.671 uVs 15:39:09 Integrated Voltage Measurement... 15:39:18 Voltage Offset Correction: v_off_ini = 13.670 uV, v_off_fin = 1.460 uV 15:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.757 uVs 15:39:18 Integrated Voltage Measurement... 15:39:27 Voltage Offset Correction: v_off_ini = 27.899 uV, v_off_fin = 32.286 uV 15:39:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.115 uVs 15:39:31 I1Y Average and RMS of Measurements VT = -245.256 +- 3.208 uVs I1Y = -49.051 +- 0.642 uTm 15:39:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:39:39 Integrated Voltage Measurement... 15:39:48 Voltage Offset Correction: v_off_ini = 36.311 uV, v_off_fin = 22.409 uV 15:39:48 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -65.275 uVs 15:39:48 Integrated Voltage Measurement... 15:39:57 Voltage Offset Correction: v_off_ini = 29.094 uV, v_off_fin = 43.829 uV 15:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.110 uVs 15:39:57 Integrated Voltage Measurement... 15:40:06 Voltage Offset Correction: v_off_ini = 36.814 uV, v_off_fin = 28.036 uV 15:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.028 uVs 15:40:06 Integrated Voltage Measurement... 15:40:15 Voltage Offset Correction: v_off_ini = 48.922 uV, v_off_fin = 53.911 uV 15:40:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.781 uVs 15:40:15 Integrated Voltage Measurement... 15:40:24 Voltage Offset Correction: v_off_ini = 51.842 uV, v_off_fin = 40.195 uV 15:40:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.932 uVs 15:40:24 Integrated Voltage Measurement... 15:40:33 Voltage Offset Correction: v_off_ini = 48.336 uV, v_off_fin = 44.281 uV 15:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.433 uVs 15:40:35 I2X Average and RMS of Measurements VT = -75.426 +- 4.909 uVs I2X = 6.939 +- 0.452 uTm^2 15:40:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:40:43 Integrated Voltage Measurement... 15:40:52 Voltage Offset Correction: v_off_ini = 60.603 uV, v_off_fin = 62.386 uV 15:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.895 uVs 15:40:52 Integrated Voltage Measurement... 15:41:01 Voltage Offset Correction: v_off_ini = 50.779 uV, v_off_fin = 53.851 uV 15:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.321 uVs 15:41:01 Integrated Voltage Measurement... 15:41:10 Voltage Offset Correction: v_off_ini = 44.552 uV, v_off_fin = 44.576 uV 15:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.703 uVs 15:41:10 Integrated Voltage Measurement... 15:41:19 Voltage Offset Correction: v_off_ini = 62.797 uV, v_off_fin = 64.377 uV 15:41:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.187 uVs 15:41:19 Integrated Voltage Measurement... 15:41:28 Voltage Offset Correction: v_off_ini = 52.748 uV, v_off_fin = 50.854 uV 15:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.924 uVs 15:41:28 Integrated Voltage Measurement... 15:41:37 Voltage Offset Correction: v_off_ini = 50.628 uV, v_off_fin = 57.257 uV 15:41:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.971 uVs 15:41:39 I2Y Average and RMS of Measurements VT = -305.167 +- 6.612 uVs I2Y = -28.075 +- 0.608 uTm^2 15:41:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:41:51 Integrated Voltage Measurement... 15:42:00 Voltage Offset Correction: v_off_ini = 63.706 uV, v_off_fin = 50.691 uV 15:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.465 uVs 15:42:00 Integrated Voltage Measurement... 15:42:09 Voltage Offset Correction: v_off_ini = 53.416 uV, v_off_fin = 48.255 uV 15:42:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 118.331 uVs 15:42:09 Integrated Voltage Measurement... 15:42:18 Voltage Offset Correction: v_off_ini = 56.823 uV, v_off_fin = 51.585 uV 15:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.094 uVs 15:42:18 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = 57.672 uV, v_off_fin = 49.361 uV 15:42:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.978 uVs 15:42:27 Integrated Voltage Measurement... 15:42:36 Voltage Offset Correction: v_off_ini = 44.056 uV, v_off_fin = 32.410 uV 15:42:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.315 uVs 15:42:36 Integrated Voltage Measurement... 15:42:45 Voltage Offset Correction: v_off_ini = 46.966 uV, v_off_fin = 71.543 uV 15:42:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.054 uVs 15:42:50 I1X Average and RMS of Measurements VT = -98.539 +- 15.196 uVs I1X = 19.708 +- 3.039 uTm 15:42:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:42:56 Integrated Voltage Measurement... 15:43:05 Voltage Offset Correction: v_off_ini = 58.885 uV, v_off_fin = 52.544 uV 15:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.978 uVs 15:43:05 Integrated Voltage Measurement... 15:43:14 Voltage Offset Correction: v_off_ini = 56.994 uV, v_off_fin = 62.416 uV 15:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.409 uVs 15:43:14 Integrated Voltage Measurement... 15:43:23 Voltage Offset Correction: v_off_ini = 45.901 uV, v_off_fin = 30.514 uV 15:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.222 uVs 15:43:23 Integrated Voltage Measurement... 15:43:32 Voltage Offset Correction: v_off_ini = 27.084 uV, v_off_fin = 48.392 uV 15:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.159 uVs 15:43:32 Integrated Voltage Measurement... 15:43:41 Voltage Offset Correction: v_off_ini = 22.871 uV, v_off_fin = 26.643 uV 15:43:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.949 uVs 15:43:41 Integrated Voltage Measurement... 15:43:50 Voltage Offset Correction: v_off_ini = 40.446 uV, v_off_fin = 45.031 uV 15:43:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.957 uVs 15:43:55 I1Y Average and RMS of Measurements VT = -211.612 +- 4.231 uVs I1Y = -42.322 +- 0.846 uTm 15:43:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:44:00 Integrated Voltage Measurement... 15:44:09 Voltage Offset Correction: v_off_ini = 42.313 uV, v_off_fin = 42.102 uV 15:44:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.815 uVs 15:44:09 Integrated Voltage Measurement... 15:44:18 Voltage Offset Correction: v_off_ini = 55.548 uV, v_off_fin = 51.553 uV 15:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.516 uVs 15:44:18 Integrated Voltage Measurement... 15:44:27 Voltage Offset Correction: v_off_ini = 46.221 uV, v_off_fin = 33.862 uV 15:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.120 uVs 15:44:27 Integrated Voltage Measurement... 15:44:36 Voltage Offset Correction: v_off_ini = 59.331 uV, v_off_fin = 66.081 uV 15:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.773 uVs 15:44:36 Integrated Voltage Measurement... 15:44:45 Voltage Offset Correction: v_off_ini = 41.118 uV, v_off_fin = 32.765 uV 15:44:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.460 uVs 15:44:45 Integrated Voltage Measurement... 15:44:54 Voltage Offset Correction: v_off_ini = 30.908 uV, v_off_fin = 27.955 uV 15:44:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.052 uVs 15:44:56 I2X Average and RMS of Measurements VT = -82.956 +- 4.618 uVs I2X = 7.632 +- 0.425 uTm^2 15:44:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:45:01 Integrated Voltage Measurement... 15:45:10 Voltage Offset Correction: v_off_ini = 38.387 uV, v_off_fin = 31.587 uV 15:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.321 uVs 15:45:11 Integrated Voltage Measurement... 15:45:19 Voltage Offset Correction: v_off_ini = 29.824 uV, v_off_fin = 38.260 uV 15:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.229 uVs 15:45:20 Integrated Voltage Measurement... 15:45:29 Voltage Offset Correction: v_off_ini = 41.306 uV, v_off_fin = 40.216 uV 15:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.225 uVs 15:45:29 Integrated Voltage Measurement... 15:45:38 Voltage Offset Correction: v_off_ini = 31.058 uV, v_off_fin = 41.127 uV 15:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.478 uVs 15:45:38 Integrated Voltage Measurement... 15:45:47 Voltage Offset Correction: v_off_ini = 40.311 uV, v_off_fin = 42.816 uV 15:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.651 uVs 15:45:47 Integrated Voltage Measurement... 15:45:56 Voltage Offset Correction: v_off_ini = 33.520 uV, v_off_fin = 43.612 uV 15:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.685 uVs 15:45:58 I2Y Average and RMS of Measurements VT = -265.265 +- 7.722 uVs I2Y = -24.404 +- 0.710 uTm^2 15:46:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:46:06 Integrated Voltage Measurement... 15:46:15 Voltage Offset Correction: v_off_ini = 37.049 uV, v_off_fin = 33.644 uV 15:46:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.846 uVs 15:46:15 Integrated Voltage Measurement... 15:46:24 Voltage Offset Correction: v_off_ini = 34.167 uV, v_off_fin = 47.420 uV 15:46:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.814 uVs 15:46:24 Integrated Voltage Measurement... 15:46:33 Voltage Offset Correction: v_off_ini = 31.308 uV, v_off_fin = 28.579 uV 15:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.561 uVs 15:46:33 Integrated Voltage Measurement... 15:46:42 Voltage Offset Correction: v_off_ini = 47.660 uV, v_off_fin = 31.993 uV 15:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.495 uVs 15:46:42 Integrated Voltage Measurement... 15:46:51 Voltage Offset Correction: v_off_ini = 44.135 uV, v_off_fin = 33.381 uV 15:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.919 uVs 15:46:51 Integrated Voltage Measurement... 15:47:00 Voltage Offset Correction: v_off_ini = 27.965 uV, v_off_fin = 39.248 uV 15:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.661 uVs 15:47:05 I1X Average and RMS of Measurements VT = -85.049 +- 10.808 uVs I1X = 17.010 +- 2.162 uTm 15:47:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 44.851 uV, v_off_fin = 39.227 uV 15:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.033 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 50.833 uV, v_off_fin = 46.893 uV 15:47:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.696 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 43.431 uV, v_off_fin = 32.815 uV 15:47:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.405 uVs 15:47:38 Integrated Voltage Measurement... 15:47:47 Voltage Offset Correction: v_off_ini = 41.253 uV, v_off_fin = 58.714 uV 15:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.667 uVs 15:47:48 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = 57.571 uV, v_off_fin = 47.022 uV 15:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.997 uVs 15:47:57 Integrated Voltage Measurement... 15:48:05 Voltage Offset Correction: v_off_ini = 73.047 uV, v_off_fin = 84.058 uV 15:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.664 uVs 15:48:10 I1Y Average and RMS of Measurements VT = -200.077 +- 5.463 uVs I1Y = -40.017 +- 1.092 uTm 15:48:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:48:15 Integrated Voltage Measurement... 15:48:24 Voltage Offset Correction: v_off_ini = 53.941 uV, v_off_fin = 60.629 uV 15:48:24 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -76.823 uVs 15:48:24 Integrated Voltage Measurement... 15:48:33 Voltage Offset Correction: v_off_ini = 71.519 uV, v_off_fin = 68.182 uV 15:48:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.232 uVs 15:48:33 Integrated Voltage Measurement... 15:48:42 Voltage Offset Correction: v_off_ini = 65.245 uV, v_off_fin = 68.461 uV 15:48:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.688 uVs 15:48:42 Integrated Voltage Measurement... 15:48:51 Voltage Offset Correction: v_off_ini = 75.682 uV, v_off_fin = 65.543 uV 15:48:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.207 uVs 15:48:51 Integrated Voltage Measurement... 15:49:00 Voltage Offset Correction: v_off_ini = 61.820 uV, v_off_fin = 63.299 uV 15:49:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.309 uVs 15:49:00 Integrated Voltage Measurement... 15:49:09 Voltage Offset Correction: v_off_ini = 80.706 uV, v_off_fin = 103.146 uV 15:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.008 uVs 15:49:12 I2X Average and RMS of Measurements VT = -68.045 +- 2.934 uVs I2X = 6.260 +- 0.270 uTm^2 15:49:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:49:17 Integrated Voltage Measurement... 15:49:26 Voltage Offset Correction: v_off_ini = 79.977 uV, v_off_fin = 80.421 uV 15:49:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.879 uVs 15:49:26 Integrated Voltage Measurement... 15:49:35 Voltage Offset Correction: v_off_ini = 69.952 uV, v_off_fin = 78.330 uV 15:49:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.248 uVs 15:49:35 Integrated Voltage Measurement... 15:49:44 Voltage Offset Correction: v_off_ini = 70.010 uV, v_off_fin = 56.700 uV 15:49:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.079 uVs 15:49:44 Integrated Voltage Measurement... 15:49:53 Voltage Offset Correction: v_off_ini = 52.636 uV, v_off_fin = 63.395 uV 15:49:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.521 uVs 15:49:53 Integrated Voltage Measurement... 15:50:02 Voltage Offset Correction: v_off_ini = 54.730 uV, v_off_fin = 53.394 uV 15:50:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.918 uVs 15:50:02 Integrated Voltage Measurement... 15:50:11 Voltage Offset Correction: v_off_ini = 63.302 uV, v_off_fin = 74.894 uV 15:50:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.410 uVs 15:50:13 I2Y Average and RMS of Measurements VT = -264.342 +- 2.778 uVs I2Y = -24.320 +- 0.256 uTm^2 15:50:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:22 Integrated Voltage Measurement... 15:50:31 Voltage Offset Correction: v_off_ini = 77.522 uV, v_off_fin = 59.217 uV 15:50:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.602 uVs 15:50:31 Integrated Voltage Measurement... 15:50:40 Voltage Offset Correction: v_off_ini = 53.730 uV, v_off_fin = 63.289 uV 15:50:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.613 uVs 15:50:40 Integrated Voltage Measurement... 15:50:49 Voltage Offset Correction: v_off_ini = 60.597 uV, v_off_fin = 55.320 uV 15:50:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.255 uVs 15:50:49 Integrated Voltage Measurement... 15:50:58 Voltage Offset Correction: v_off_ini = 64.135 uV, v_off_fin = 76.616 uV 15:50:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.639 uVs 15:50:58 Integrated Voltage Measurement... 15:51:07 Voltage Offset Correction: v_off_ini = 61.252 uV, v_off_fin = 65.852 uV 15:51:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.632 uVs 15:51:07 Integrated Voltage Measurement... 15:51:16 Voltage Offset Correction: v_off_ini = 69.431 uV, v_off_fin = 75.291 uV 15:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.439 uVs 15:51:20 I1X Average and RMS of Measurements VT = -76.863 +- 13.726 uVs I1X = 15.373 +- 2.745 uTm 15:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:27 Integrated Voltage Measurement... 15:51:36 Voltage Offset Correction: v_off_ini = 72.184 uV, v_off_fin = 56.178 uV 15:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.618 uVs 15:51:36 Integrated Voltage Measurement... 15:51:45 Voltage Offset Correction: v_off_ini = 57.472 uV, v_off_fin = 75.096 uV 15:51:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.241 uVs 15:51:45 Integrated Voltage Measurement... 15:51:54 Voltage Offset Correction: v_off_ini = 69.625 uV, v_off_fin = 65.596 uV 15:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.920 uVs 15:51:54 Integrated Voltage Measurement... 15:52:03 Voltage Offset Correction: v_off_ini = 54.863 uV, v_off_fin = 81.240 uV 15:52:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.927 uVs 15:52:03 Integrated Voltage Measurement... 15:52:12 Voltage Offset Correction: v_off_ini = 65.889 uV, v_off_fin = 55.125 uV 15:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.616 uVs 15:52:12 Integrated Voltage Measurement... 15:52:21 Voltage Offset Correction: v_off_ini = 64.572 uV, v_off_fin = 75.257 uV 15:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.693 uVs 15:52:25 I1Y Average and RMS of Measurements VT = -201.003 +- 3.389 uVs I1Y = -40.201 +- 0.678 uTm 15:52:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:30 Integrated Voltage Measurement... 15:52:39 Voltage Offset Correction: v_off_ini = 59.801 uV, v_off_fin = 55.241 uV 15:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.551 uVs 15:52:39 Integrated Voltage Measurement... 15:52:48 Voltage Offset Correction: v_off_ini = 52.739 uV, v_off_fin = 68.390 uV 15:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.600 uVs 15:52:48 Integrated Voltage Measurement... 15:52:57 Voltage Offset Correction: v_off_ini = 68.341 uV, v_off_fin = 66.137 uV 15:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.607 uVs 15:52:57 Integrated Voltage Measurement... 15:53:06 Voltage Offset Correction: v_off_ini = 58.274 uV, v_off_fin = 69.625 uV 15:53:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.652 uVs 15:53:06 Integrated Voltage Measurement... 15:53:15 Voltage Offset Correction: v_off_ini = 63.806 uV, v_off_fin = 44.731 uV 15:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.106 uVs 15:53:15 Integrated Voltage Measurement... 15:53:24 Voltage Offset Correction: v_off_ini = 68.709 uV, v_off_fin = 76.183 uV 15:53:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.477 uVs 15:53:27 I2X Average and RMS of Measurements VT = -66.999 +- 2.085 uVs I2X = 6.164 +- 0.192 uTm^2 15:53:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:32 Integrated Voltage Measurement... 15:53:41 Voltage Offset Correction: v_off_ini = 60.325 uV, v_off_fin = 54.452 uV 15:53:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.819 uVs 15:53:41 Integrated Voltage Measurement... 15:53:50 Voltage Offset Correction: v_off_ini = 67.105 uV, v_off_fin = 75.047 uV 15:53:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.919 uVs 15:53:50 Integrated Voltage Measurement... 15:53:59 Voltage Offset Correction: v_off_ini = 86.296 uV, v_off_fin = 76.184 uV 15:53:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.143 uVs 15:53:59 Integrated Voltage Measurement... 15:54:08 Voltage Offset Correction: v_off_ini = 81.191 uV, v_off_fin = 76.413 uV 15:54:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.858 uVs 15:54:08 Integrated Voltage Measurement... 15:54:17 Voltage Offset Correction: v_off_ini = 81.109 uV, v_off_fin = 75.656 uV 15:54:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.249 uVs 15:54:17 Integrated Voltage Measurement... 15:54:26 Voltage Offset Correction: v_off_ini = 76.628 uV, v_off_fin = 66.408 uV 15:54:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.687 uVs 15:54:29 I2Y Average and RMS of Measurements VT = -269.779 +- 8.987 uVs I2Y = -24.820 +- 0.827 uTm^2 15:54:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:54:37 Integrated Voltage Measurement... 15:54:46 Voltage Offset Correction: v_off_ini = 67.172 uV, v_off_fin = 61.142 uV 15:54:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.980 uVs 15:54:46 Integrated Voltage Measurement... 15:54:55 Voltage Offset Correction: v_off_ini = 59.443 uV, v_off_fin = 76.065 uV 15:54:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.368 uVs 15:54:55 Integrated Voltage Measurement... 15:55:04 Voltage Offset Correction: v_off_ini = 67.494 uV, v_off_fin = 67.431 uV 15:55:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.696 uVs 15:55:04 Integrated Voltage Measurement... 15:55:13 Voltage Offset Correction: v_off_ini = 72.260 uV, v_off_fin = 64.790 uV 15:55:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.333 uVs 15:55:13 Integrated Voltage Measurement... 15:55:22 Voltage Offset Correction: v_off_ini = 72.474 uV, v_off_fin = 62.365 uV 15:55:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.547 uVs 15:55:22 Integrated Voltage Measurement... 15:55:31 Voltage Offset Correction: v_off_ini = 68.299 uV, v_off_fin = 68.568 uV 15:55:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.545 uVs 15:55:35 I1X Average and RMS of Measurements VT = -61.411 +- 3.833 uVs I1X = 12.283 +- 0.767 uTm 15:55:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:55:42 Integrated Voltage Measurement... 15:55:51 Voltage Offset Correction: v_off_ini = 59.450 uV, v_off_fin = 49.478 uV 15:55:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.403 uVs 15:55:51 Integrated Voltage Measurement... 15:56:00 Voltage Offset Correction: v_off_ini = 42.277 uV, v_off_fin = 63.576 uV 15:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.063 uVs 15:56:00 Integrated Voltage Measurement... 15:56:09 Voltage Offset Correction: v_off_ini = 46.098 uV, v_off_fin = 40.612 uV 15:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.556 uVs 15:56:09 Integrated Voltage Measurement... 15:56:18 Voltage Offset Correction: v_off_ini = 72.538 uV, v_off_fin = 69.483 uV 15:56:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.372 uVs 15:56:18 Integrated Voltage Measurement... 15:56:27 Voltage Offset Correction: v_off_ini = 67.115 uV, v_off_fin = 49.954 uV 15:56:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.458 uVs 15:56:27 Integrated Voltage Measurement... 15:56:36 Voltage Offset Correction: v_off_ini = 47.426 uV, v_off_fin = 57.239 uV 15:56:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.554 uVs 15:56:40 I1Y Average and RMS of Measurements VT = -202.401 +- 6.602 uVs I1Y = -40.479 +- 1.320 uTm 15:56:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:56:45 Integrated Voltage Measurement... 15:56:55 Voltage Offset Correction: v_off_ini = 56.399 uV, v_off_fin = 51.538 uV 15:56:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.664 uVs 15:56:55 Integrated Voltage Measurement... 15:57:04 Voltage Offset Correction: v_off_ini = 56.912 uV, v_off_fin = 64.259 uV 15:57:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.765 uVs 15:57:04 Integrated Voltage Measurement... 15:57:13 Voltage Offset Correction: v_off_ini = 50.786 uV, v_off_fin = 42.190 uV 15:57:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -41.138 uVs 15:57:13 Integrated Voltage Measurement... 15:57:22 Voltage Offset Correction: v_off_ini = 44.219 uV, v_off_fin = 54.881 uV 15:57:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.237 uVs 15:57:22 Integrated Voltage Measurement... 15:57:31 Voltage Offset Correction: v_off_ini = 54.768 uV, v_off_fin = 30.359 uV 15:57:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.780 uVs 15:57:31 Integrated Voltage Measurement... 15:57:40 Voltage Offset Correction: v_off_ini = 43.267 uV, v_off_fin = 57.374 uV 15:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.734 uVs 15:57:42 I2X Average and RMS of Measurements VT = -48.386 +- 2.713 uVs I2X = 4.452 +- 0.249 uTm^2 15:57:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:57:47 Integrated Voltage Measurement... 15:57:56 Voltage Offset Correction: v_off_ini = 50.760 uV, v_off_fin = 58.638 uV 15:57:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.050 uVs 15:57:56 Integrated Voltage Measurement... 15:58:05 Voltage Offset Correction: v_off_ini = 48.124 uV, v_off_fin = 40.168 uV 15:58:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.555 uVs 15:58:05 Integrated Voltage Measurement... 15:58:14 Voltage Offset Correction: v_off_ini = 36.592 uV, v_off_fin = 41.531 uV 15:58:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.905 uVs 15:58:14 Integrated Voltage Measurement... 15:58:23 Voltage Offset Correction: v_off_ini = 39.550 uV, v_off_fin = 44.448 uV 15:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.654 uVs 15:58:23 Integrated Voltage Measurement... 15:58:32 Voltage Offset Correction: v_off_ini = 42.517 uV, v_off_fin = 33.846 uV 15:58:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.379 uVs 15:58:32 Integrated Voltage Measurement... 15:58:41 Voltage Offset Correction: v_off_ini = 48.303 uV, v_off_fin = 35.773 uV 15:58:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.384 uVs 15:58:44 I2Y Average and RMS of Measurements VT = -263.488 +- 9.385 uVs I2Y = -24.241 +- 0.863 uTm^2 15:58:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:58:52 Integrated Voltage Measurement... 15:59:01 Voltage Offset Correction: v_off_ini = 34.941 uV, v_off_fin = 29.938 uV 15:59:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -42.336 uVs 15:59:01 Integrated Voltage Measurement... 15:59:10 Voltage Offset Correction: v_off_ini = 34.404 uV, v_off_fin = 52.645 uV 15:59:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.231 uVs 15:59:10 Integrated Voltage Measurement... 15:59:19 Voltage Offset Correction: v_off_ini = 48.607 uV, v_off_fin = 43.905 uV 15:59:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.028 uVs 15:59:19 Integrated Voltage Measurement... 15:59:28 Voltage Offset Correction: v_off_ini = 48.980 uV, v_off_fin = 42.728 uV 15:59:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.292 uVs 15:59:28 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 46.772 uV, v_off_fin = 44.653 uV 15:59:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.269 uVs 15:59:37 Integrated Voltage Measurement... 15:59:46 Voltage Offset Correction: v_off_ini = 33.017 uV, v_off_fin = 53.193 uV 15:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.343 uVs 15:59:51 I1X Average and RMS of Measurements VT = -48.416 +- 4.467 uVs I1X = 9.683 +- 0.894 uTm 15:59:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:59:57 Integrated Voltage Measurement... 16:00:06 Voltage Offset Correction: v_off_ini = 42.814 uV, v_off_fin = 21.159 uV 16:00:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.798 uVs 16:00:06 Integrated Voltage Measurement... 16:00:15 Voltage Offset Correction: v_off_ini = 40.249 uV, v_off_fin = 54.936 uV 16:00:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.695 uVs 16:00:15 Integrated Voltage Measurement... 16:00:24 Voltage Offset Correction: v_off_ini = 39.855 uV, v_off_fin = 36.468 uV 16:00:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.199 uVs 16:00:24 Integrated Voltage Measurement... 16:00:33 Voltage Offset Correction: v_off_ini = 38.964 uV, v_off_fin = 48.287 uV 16:00:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.175 uVs 16:00:33 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = 41.894 uV, v_off_fin = 36.361 uV 16:00:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.599 uVs 16:00:42 Integrated Voltage Measurement... 16:00:51 Voltage Offset Correction: v_off_ini = 52.787 uV, v_off_fin = 50.757 uV 16:00:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.985 uVs 16:00:56 I1Y Average and RMS of Measurements VT = -200.575 +- 6.755 uVs I1Y = -40.114 +- 1.349 uTm 16:00:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:01:01 Integrated Voltage Measurement... 16:01:10 Voltage Offset Correction: v_off_ini = 39.795 uV, v_off_fin = 32.016 uV 16:01:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.362 uVs 16:01:10 Integrated Voltage Measurement... 16:01:19 Voltage Offset Correction: v_off_ini = 44.924 uV, v_off_fin = 57.351 uV 16:01:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.867 uVs 16:01:19 Integrated Voltage Measurement... 16:01:28 Voltage Offset Correction: v_off_ini = 41.070 uV, v_off_fin = 34.870 uV 16:01:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -34.997 uVs 16:01:28 Integrated Voltage Measurement... 16:01:37 Voltage Offset Correction: v_off_ini = 45.468 uV, v_off_fin = 53.391 uV 16:01:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.051 uVs 16:01:37 Integrated Voltage Measurement... 16:01:46 Voltage Offset Correction: v_off_ini = 45.683 uV, v_off_fin = 37.914 uV 16:01:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.468 uVs 16:01:46 Integrated Voltage Measurement... 16:01:55 Voltage Offset Correction: v_off_ini = 49.886 uV, v_off_fin = 64.851 uV 16:01:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.978 uVs 16:01:57 I2X Average and RMS of Measurements VT = -28.954 +- 8.389 uVs I2X = 2.664 +- 0.772 uTm^2 16:02:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:02:03 Integrated Voltage Measurement... 16:02:12 Voltage Offset Correction: v_off_ini = 61.967 uV, v_off_fin = 53.597 uV 16:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.503 uVs 16:02:12 Integrated Voltage Measurement... 16:02:21 Voltage Offset Correction: v_off_ini = 61.893 uV, v_off_fin = 64.032 uV 16:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.869 uVs 16:02:21 Integrated Voltage Measurement... 16:02:30 Voltage Offset Correction: v_off_ini = 68.435 uV, v_off_fin = 60.835 uV 16:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.844 uVs 16:02:30 Integrated Voltage Measurement... 16:02:39 Voltage Offset Correction: v_off_ini = 63.886 uV, v_off_fin = 60.327 uV 16:02:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.176 uVs 16:02:39 Integrated Voltage Measurement... 16:02:48 Voltage Offset Correction: v_off_ini = 53.095 uV, v_off_fin = 62.874 uV 16:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.512 uVs 16:02:48 Integrated Voltage Measurement... 16:02:57 Voltage Offset Correction: v_off_ini = 54.224 uV, v_off_fin = 58.297 uV 16:02:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.370 uVs 16:02:59 I2Y Average and RMS of Measurements VT = -264.879 +- 2.783 uVs I2Y = -24.369 +- 0.256 uTm^2 16:03:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:03:19 Integrated Voltage Measurement... 16:03:28 Voltage Offset Correction: v_off_ini = 59.186 uV, v_off_fin = 57.225 uV 16:03:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.345 uVs 16:03:28 Integrated Voltage Measurement... 16:03:37 Voltage Offset Correction: v_off_ini = 70.357 uV, v_off_fin = 80.197 uV 16:03:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.132 uVs 16:03:37 Integrated Voltage Measurement... 16:03:46 Voltage Offset Correction: v_off_ini = 73.087 uV, v_off_fin = 75.588 uV 16:03:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.846 uVs 16:03:46 Integrated Voltage Measurement... 16:03:55 Voltage Offset Correction: v_off_ini = 68.309 uV, v_off_fin = 60.135 uV 16:03:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.025 uVs 16:03:55 Integrated Voltage Measurement... 16:04:04 Voltage Offset Correction: v_off_ini = 67.670 uV, v_off_fin = 71.593 uV 16:04:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.877 uVs 16:04:05 Integrated Voltage Measurement... 16:04:13 Voltage Offset Correction: v_off_ini = 78.698 uV, v_off_fin = 78.699 uV 16:04:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.043 uVs 16:04:18 I1X Average and RMS of Measurements VT = -94.878 +- 2.813 uVs I1X = 18.976 +- 0.563 uTm 16:04:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:04:25 Integrated Voltage Measurement... 16:04:33 Voltage Offset Correction: v_off_ini = 82.129 uV, v_off_fin = 84.789 uV 16:04:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.797 uVs 16:04:34 Integrated Voltage Measurement... 16:04:42 Voltage Offset Correction: v_off_ini = 86.964 uV, v_off_fin = 98.071 uV 16:04:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.054 uVs 16:04:43 Integrated Voltage Measurement... 16:04:51 Voltage Offset Correction: v_off_ini = 92.815 uV, v_off_fin = 77.533 uV 16:04:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.685 uVs 16:04:52 Integrated Voltage Measurement... 16:05:00 Voltage Offset Correction: v_off_ini = 81.227 uV, v_off_fin = 94.390 uV 16:05:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.771 uVs 16:05:01 Integrated Voltage Measurement... 16:05:10 Voltage Offset Correction: v_off_ini = 72.204 uV, v_off_fin = 55.559 uV 16:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -142.209 uVs 16:05:10 Integrated Voltage Measurement... 16:05:19 Voltage Offset Correction: v_off_ini = 62.391 uV, v_off_fin = 80.438 uV 16:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.787 uVs 16:05:23 I1Y Average and RMS of Measurements VT = -159.217 +- 7.056 uVs I1Y = -31.843 +- 1.411 uTm 16:05:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:05:31 Integrated Voltage Measurement... 16:05:40 Voltage Offset Correction: v_off_ini = 78.020 uV, v_off_fin = 64.829 uV 16:05:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.270 uVs 16:05:40 Integrated Voltage Measurement... 16:05:49 Voltage Offset Correction: v_off_ini = 84.610 uV, v_off_fin = 91.016 uV 16:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.577 uVs 16:05:49 Integrated Voltage Measurement... 16:05:58 Voltage Offset Correction: v_off_ini = 74.139 uV, v_off_fin = 73.095 uV 16:05:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.315 uVs 16:05:58 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 71.144 uV, v_off_fin = 81.683 uV 16:06:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.793 uVs 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 81.663 uV, v_off_fin = 55.755 uV 16:06:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.711 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 71.814 uV, v_off_fin = 75.181 uV 16:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.393 uVs 16:06:27 I2X Average and RMS of Measurements VT = -76.176 +- 4.980 uVs I2X = 7.008 +- 0.458 uTm^2 16:06:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:06:35 Integrated Voltage Measurement... 16:06:44 Voltage Offset Correction: v_off_ini = 65.202 uV, v_off_fin = 69.643 uV 16:06:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.209 uVs 16:06:44 Integrated Voltage Measurement... 16:06:53 Voltage Offset Correction: v_off_ini = 71.866 uV, v_off_fin = 53.872 uV 16:06:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.438 uVs 16:06:53 Integrated Voltage Measurement... 16:07:02 Voltage Offset Correction: v_off_ini = 59.715 uV, v_off_fin = 59.439 uV 16:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.573 uVs 16:07:02 Integrated Voltage Measurement... 16:07:11 Voltage Offset Correction: v_off_ini = 55.206 uV, v_off_fin = 54.573 uV 16:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.249 uVs 16:07:11 Integrated Voltage Measurement... 16:07:20 Voltage Offset Correction: v_off_ini = 46.221 uV, v_off_fin = 50.631 uV 16:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.150 uVs 16:07:20 Integrated Voltage Measurement... 16:07:29 Voltage Offset Correction: v_off_ini = 46.868 uV, v_off_fin = 56.441 uV 16:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.471 uVs 16:07:32 I2Y Average and RMS of Measurements VT = -209.848 +- 9.609 uVs I2Y = -19.306 +- 0.884 uTm^2 16:07:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:07:41 Integrated Voltage Measurement... 16:07:50 Voltage Offset Correction: v_off_ini = 50.981 uV, v_off_fin = 47.016 uV 16:07:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.564 uVs 16:07:50 Integrated Voltage Measurement... 16:07:59 Voltage Offset Correction: v_off_ini = 43.837 uV, v_off_fin = 47.891 uV 16:07:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.736 uVs 16:07:59 Integrated Voltage Measurement... 16:08:08 Voltage Offset Correction: v_off_ini = 40.939 uV, v_off_fin = 30.968 uV 16:08:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.922 uVs 16:08:08 Integrated Voltage Measurement... 16:08:17 Voltage Offset Correction: v_off_ini = 49.061 uV, v_off_fin = 54.106 uV 16:08:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.868 uVs 16:08:17 Integrated Voltage Measurement... 16:08:26 Voltage Offset Correction: v_off_ini = 39.748 uV, v_off_fin = 29.292 uV 16:08:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.501 uVs 16:08:26 Integrated Voltage Measurement... 16:08:35 Voltage Offset Correction: v_off_ini = 31.115 uV, v_off_fin = 29.495 uV 16:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.751 uVs 16:08:39 I1X Average and RMS of Measurements VT = -84.057 +- 7.043 uVs I1X = 16.812 +- 1.409 uTm 16:08:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:08:46 Integrated Voltage Measurement... 16:08:55 Voltage Offset Correction: v_off_ini = 29.290 uV, v_off_fin = 15.845 uV 16:08:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.434 uVs 16:08:55 Integrated Voltage Measurement... 16:09:04 Voltage Offset Correction: v_off_ini = 15.268 uV, v_off_fin = 22.800 uV 16:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.000 uVs 16:09:04 Integrated Voltage Measurement... 16:09:13 Voltage Offset Correction: v_off_ini = 27.504 uV, v_off_fin = 13.537 uV 16:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.261 uVs 16:09:13 Integrated Voltage Measurement... 16:09:22 Voltage Offset Correction: v_off_ini = 17.805 uV, v_off_fin = 22.928 uV 16:09:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.978 uVs 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 8.164 uV, v_off_fin = 6.552 uV 16:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.407 uVs 16:09:31 Integrated Voltage Measurement... 16:09:40 Voltage Offset Correction: v_off_ini = 16.119 uV, v_off_fin = 33.793 uV 16:09:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.565 uVs 16:09:44 I1Y Average and RMS of Measurements VT = -190.274 +- 0.668 uVs I1Y = -38.055 +- 0.134 uTm 16:09:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:09:52 Integrated Voltage Measurement... 16:10:01 Voltage Offset Correction: v_off_ini = 17.544 uV, v_off_fin = 13.305 uV 16:10:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.623 uVs 16:10:01 Integrated Voltage Measurement... 16:10:10 Voltage Offset Correction: v_off_ini = 29.935 uV, v_off_fin = 49.995 uV 16:10:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.829 uVs 16:10:10 Integrated Voltage Measurement... 16:10:19 Voltage Offset Correction: v_off_ini = 34.051 uV, v_off_fin = 9.844 uV 16:10:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.122 uVs 16:10:19 Integrated Voltage Measurement... 16:10:28 Voltage Offset Correction: v_off_ini = 21.219 uV, v_off_fin = 14.636 uV 16:10:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.924 uVs 16:10:28 Integrated Voltage Measurement... 16:10:37 Voltage Offset Correction: v_off_ini = 22.191 uV, v_off_fin = 4.889 uV 16:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.720 uVs 16:10:37 Integrated Voltage Measurement... 16:10:46 Voltage Offset Correction: v_off_ini = 7.342 uV, v_off_fin = 18.531 uV 16:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.805 uVs 16:10:49 I2X Average and RMS of Measurements VT = -74.004 +- 6.380 uVs I2X = 6.808 +- 0.587 uTm^2 16:10:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:10:56 Integrated Voltage Measurement... 16:11:05 Voltage Offset Correction: v_off_ini = 10.558 uV, v_off_fin = -4.834 uV 16:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.190 uVs 16:11:05 Integrated Voltage Measurement... 16:11:14 Voltage Offset Correction: v_off_ini = -6.517 uV, v_off_fin = 0.349 uV 16:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.351 uVs 16:11:14 Integrated Voltage Measurement... 16:11:23 Voltage Offset Correction: v_off_ini = -8.683 uV, v_off_fin = -1.568 uV 16:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.045 uVs 16:11:23 Integrated Voltage Measurement... 16:11:32 Voltage Offset Correction: v_off_ini = 3.785 uV, v_off_fin = 10.059 uV 16:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.421 uVs 16:11:33 Integrated Voltage Measurement... 16:11:42 Voltage Offset Correction: v_off_ini = 15.754 uV, v_off_fin = 8.971 uV 16:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.450 uVs 16:11:42 Integrated Voltage Measurement... 16:11:51 Voltage Offset Correction: v_off_ini = 20.786 uV, v_off_fin = 9.311 uV 16:11:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.647 uVs 16:11:53 I2Y Average and RMS of Measurements VT = -245.517 +- 2.919 uVs I2Y = -22.588 +- 0.269 uTm^2 16:11:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:02 Integrated Voltage Measurement... 16:12:11 Voltage Offset Correction: v_off_ini = 7.531 uV, v_off_fin = 2.667 uV 16:12:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.453 uVs 16:12:11 Integrated Voltage Measurement... 16:12:20 Voltage Offset Correction: v_off_ini = 10.423 uV, v_off_fin = 8.103 uV 16:12:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 86.728 uVs 16:12:20 Integrated Voltage Measurement... 16:12:29 Voltage Offset Correction: v_off_ini = 20.039 uV, v_off_fin = 6.152 uV 16:12:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.925 uVs 16:12:29 Integrated Voltage Measurement... 16:12:38 Voltage Offset Correction: v_off_ini = 9.807 uV, v_off_fin = 6.144 uV 16:12:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 82.939 uVs 16:12:38 Integrated Voltage Measurement... 16:12:47 Voltage Offset Correction: v_off_ini = -0.077 uV, v_off_fin = 2.554 uV 16:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.968 uVs 16:12:47 Integrated Voltage Measurement... 16:12:56 Voltage Offset Correction: v_off_ini = 8.715 uV, v_off_fin = 8.097 uV 16:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.980 uVs 16:13:00 I1X Average and RMS of Measurements VT = -91.665 +- 3.919 uVs I1X = 18.334 +- 0.784 uTm 16:13:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:07 Integrated Voltage Measurement... 16:13:16 Voltage Offset Correction: v_off_ini = -21.270 uV, v_off_fin = -20.325 uV 16:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -204.257 uVs 16:13:16 Integrated Voltage Measurement... 16:13:25 Voltage Offset Correction: v_off_ini = 1.825 uV, v_off_fin = 6.680 uV 16:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.062 uVs 16:13:25 Integrated Voltage Measurement... 16:13:34 Voltage Offset Correction: v_off_ini = -11.077 uV, v_off_fin = -1.710 uV 16:13:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.082 uVs 16:13:34 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = -6.742 uV, v_off_fin = 11.018 uV 16:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.667 uVs 16:13:43 Integrated Voltage Measurement... 16:13:52 Voltage Offset Correction: v_off_ini = -3.632 uV, v_off_fin = 0.211 uV 16:13:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.645 uVs 16:13:52 Integrated Voltage Measurement... 16:14:01 Voltage Offset Correction: v_off_ini = 27.369 uV, v_off_fin = 18.016 uV 16:14:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.664 uVs 16:14:05 I1Y Average and RMS of Measurements VT = -199.230 +- 5.719 uVs I1Y = -39.847 +- 1.144 uTm 16:14:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:13 Integrated Voltage Measurement... 16:14:22 Voltage Offset Correction: v_off_ini = 8.181 uV, v_off_fin = 9.695 uV 16:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.855 uVs 16:14:22 Integrated Voltage Measurement... 16:14:31 Voltage Offset Correction: v_off_ini = 32.054 uV, v_off_fin = 29.933 uV 16:14:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.861 uVs 16:14:31 Integrated Voltage Measurement... 16:14:40 Voltage Offset Correction: v_off_ini = 16.000 uV, v_off_fin = 6.360 uV 16:14:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.939 uVs 16:14:40 Integrated Voltage Measurement... 16:14:49 Voltage Offset Correction: v_off_ini = 10.751 uV, v_off_fin = 26.002 uV 16:14:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.828 uVs 16:14:49 Integrated Voltage Measurement... 16:14:58 Voltage Offset Correction: v_off_ini = 20.794 uV, v_off_fin = 11.154 uV 16:14:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.852 uVs 16:14:58 Integrated Voltage Measurement... 16:15:07 Voltage Offset Correction: v_off_ini = 12.620 uV, v_off_fin = 14.659 uV 16:15:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.797 uVs 16:15:10 I2X Average and RMS of Measurements VT = -74.022 +- 5.967 uVs I2X = 6.810 +- 0.549 uTm^2 16:15:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:18 Integrated Voltage Measurement... 16:15:27 Voltage Offset Correction: v_off_ini = 11.087 uV, v_off_fin = 21.168 uV 16:15:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.782 uVs 16:15:27 Integrated Voltage Measurement... 16:15:36 Voltage Offset Correction: v_off_ini = 22.965 uV, v_off_fin = 36.759 uV 16:15:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.844 uVs 16:15:36 Integrated Voltage Measurement... 16:15:45 Voltage Offset Correction: v_off_ini = 22.834 uV, v_off_fin = 26.783 uV 16:15:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.996 uVs 16:15:45 Integrated Voltage Measurement... 16:15:54 Voltage Offset Correction: v_off_ini = 18.718 uV, v_off_fin = 27.072 uV 16:15:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.357 uVs 16:15:54 Integrated Voltage Measurement... 16:16:03 Voltage Offset Correction: v_off_ini = 26.039 uV, v_off_fin = 11.977 uV 16:16:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.664 uVs 16:16:03 Integrated Voltage Measurement... 16:16:12 Voltage Offset Correction: v_off_ini = 11.802 uV, v_off_fin = 18.216 uV 16:16:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.177 uVs 16:16:14 I2Y Average and RMS of Measurements VT = -257.303 +- 4.178 uVs I2Y = -23.672 +- 0.384 uTm^2 16:16:19 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:16:23 Integrated Voltage Measurement... 16:16:32 Voltage Offset Correction: v_off_ini = 14.692 uV, v_off_fin = 7.136 uV 16:16:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.619 uVs 16:16:32 Integrated Voltage Measurement... 16:16:41 Voltage Offset Correction: v_off_ini = 12.045 uV, v_off_fin = 23.915 uV 16:16:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 92.304 uVs 16:16:41 Integrated Voltage Measurement... 16:16:50 Voltage Offset Correction: v_off_ini = 11.390 uV, v_off_fin = 0.647 uV 16:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.315 uVs 16:16:50 Integrated Voltage Measurement... 16:16:59 Voltage Offset Correction: v_off_ini = 10.773 uV, v_off_fin = 15.164 uV 16:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.340 uVs 16:16:59 Integrated Voltage Measurement... 16:17:08 Voltage Offset Correction: v_off_ini = 16.833 uV, v_off_fin = 5.185 uV 16:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.557 uVs 16:17:08 Integrated Voltage Measurement... 16:17:17 Voltage Offset Correction: v_off_ini = 14.239 uV, v_off_fin = 11.356 uV 16:17:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.744 uVs 16:17:22 I1X Average and RMS of Measurements VT = -86.980 +- 8.425 uVs I1X = 17.397 +- 1.686 uTm 16:17:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:17:28 Integrated Voltage Measurement... 16:17:37 Voltage Offset Correction: v_off_ini = -12.161 uV, v_off_fin = -10.320 uV 16:17:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.379 uVs 16:17:37 Integrated Voltage Measurement... 16:17:46 Voltage Offset Correction: v_off_ini = -0.259 uV, v_off_fin = 1.834 uV 16:17:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.162 uVs 16:17:47 Integrated Voltage Measurement... 16:17:55 Voltage Offset Correction: v_off_ini = -6.388 uV, v_off_fin = -15.240 uV 16:17:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.497 uVs 16:17:56 Integrated Voltage Measurement... 16:18:04 Voltage Offset Correction: v_off_ini = -8.653 uV, v_off_fin = -0.217 uV 16:18:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.235 uVs 16:18:05 Integrated Voltage Measurement... 16:18:13 Voltage Offset Correction: v_off_ini = 4.877 uV, v_off_fin = -6.373 uV 16:18:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.763 uVs 16:18:14 Integrated Voltage Measurement... 16:18:22 Voltage Offset Correction: v_off_ini = -13.806 uV, v_off_fin = 5.772 uV 16:18:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.867 uVs 16:18:27 I1Y Average and RMS of Measurements VT = -230.317 +- 5.107 uVs I1Y = -46.063 +- 1.021 uTm 16:18:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:18:34 Integrated Voltage Measurement... 16:18:43 Voltage Offset Correction: v_off_ini = -2.473 uV, v_off_fin = -15.292 uV 16:18:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.015 uVs 16:18:44 Integrated Voltage Measurement... 16:18:53 Voltage Offset Correction: v_off_ini = -1.195 uV, v_off_fin = 7.577 uV 16:18:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.089 uVs 16:18:53 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = -1.833 uV, v_off_fin = -16.837 uV 16:19:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.445 uVs 16:19:02 Integrated Voltage Measurement... 16:19:11 Voltage Offset Correction: v_off_ini = 0.044 uV, v_off_fin = 14.689 uV 16:19:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.501 uVs 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = -3.003 uV, v_off_fin = -18.435 uV 16:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.925 uVs 16:19:20 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = -3.467 uV, v_off_fin = -6.764 uV 16:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.006 uVs 16:19:31 I2X Average and RMS of Measurements VT = -87.497 +- 3.520 uVs I2X = 8.050 +- 0.324 uTm^2 16:19:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:19:39 Integrated Voltage Measurement... 16:19:48 Voltage Offset Correction: v_off_ini = -8.397 uV, v_off_fin = -3.520 uV 16:19:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.994 uVs 16:19:48 Integrated Voltage Measurement... 16:19:57 Voltage Offset Correction: v_off_ini = -13.839 uV, v_off_fin = -9.269 uV 16:19:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.947 uVs 16:19:57 Integrated Voltage Measurement... 16:20:06 Voltage Offset Correction: v_off_ini = -5.226 uV, v_off_fin = -10.796 uV 16:20:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.224 uVs 16:20:06 Integrated Voltage Measurement... 16:20:15 Voltage Offset Correction: v_off_ini = -11.646 uV, v_off_fin = -14.179 uV 16:20:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.064 uVs 16:20:15 Integrated Voltage Measurement... 16:20:24 Voltage Offset Correction: v_off_ini = -21.731 uV, v_off_fin = -12.135 uV 16:20:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.214 uVs 16:20:24 Integrated Voltage Measurement... 16:20:33 Voltage Offset Correction: v_off_ini = -2.295 uV, v_off_fin = -10.243 uV 16:20:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.347 uVs 16:20:36 I2Y Average and RMS of Measurements VT = -277.465 +- 4.182 uVs I2Y = -25.527 +- 0.385 uTm^2 16:20:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:20:45 Integrated Voltage Measurement... 16:20:53 Voltage Offset Correction: v_off_ini = -15.956 uV, v_off_fin = -33.389 uV 16:20:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.075 uVs 16:20:54 Integrated Voltage Measurement... 16:21:02 Voltage Offset Correction: v_off_ini = -42.812 uV, v_off_fin = -30.968 uV 16:21:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.235 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = -31.798 uV, v_off_fin = -32.379 uV 16:21:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.069 uVs 16:21:12 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = -39.176 uV, v_off_fin = -28.397 uV 16:21:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.952 uVs 16:21:21 Integrated Voltage Measurement... 16:21:30 Voltage Offset Correction: v_off_ini = -36.460 uV, v_off_fin = -31.263 uV 16:21:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.155 uVs 16:21:30 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = -45.345 uV, v_off_fin = -44.887 uV 16:21:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.560 uVs 16:21:43 I1X Average and RMS of Measurements VT = -97.674 +- 5.773 uVs I1X = 19.535 +- 1.155 uTm 16:21:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:21:50 Integrated Voltage Measurement... 16:21:59 Voltage Offset Correction: v_off_ini = -44.745 uV, v_off_fin = -55.469 uV 16:21:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -237.738 uVs 16:21:59 Integrated Voltage Measurement... 16:22:08 Voltage Offset Correction: v_off_ini = -53.287 uV, v_off_fin = -37.791 uV 16:22:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 234.492 uVs 16:22:08 Integrated Voltage Measurement... 16:22:17 Voltage Offset Correction: v_off_ini = -37.902 uV, v_off_fin = -49.584 uV 16:22:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.056 uVs 16:22:17 Integrated Voltage Measurement... 16:22:26 Voltage Offset Correction: v_off_ini = -42.568 uV, v_off_fin = -27.021 uV 16:22:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.870 uVs 16:22:26 Integrated Voltage Measurement... 16:22:35 Voltage Offset Correction: v_off_ini = -45.686 uV, v_off_fin = -53.597 uV 16:22:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.184 uVs 16:22:35 Integrated Voltage Measurement... 16:22:44 Voltage Offset Correction: v_off_ini = -22.751 uV, v_off_fin = -20.144 uV 16:22:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.267 uVs 16:22:48 I1Y Average and RMS of Measurements VT = -243.434 +- 12.080 uVs I1Y = -48.688 +- 2.415 uTm 16:22:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:22:56 Integrated Voltage Measurement... 16:23:05 Voltage Offset Correction: v_off_ini = -39.591 uV, v_off_fin = -47.157 uV 16:23:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.157 uVs 16:23:05 Integrated Voltage Measurement... 16:23:14 Voltage Offset Correction: v_off_ini = -22.917 uV, v_off_fin = -39.169 uV 16:23:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.434 uVs 16:23:14 Integrated Voltage Measurement... 16:23:23 Voltage Offset Correction: v_off_ini = -44.280 uV, v_off_fin = -47.006 uV 16:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.542 uVs 16:23:23 Integrated Voltage Measurement... 16:23:32 Voltage Offset Correction: v_off_ini = -56.656 uV, v_off_fin = -37.896 uV 16:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.610 uVs 16:23:32 Integrated Voltage Measurement... 16:23:41 Voltage Offset Correction: v_off_ini = -40.994 uV, v_off_fin = -50.553 uV 16:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.402 uVs 16:23:41 Integrated Voltage Measurement... 16:23:50 Voltage Offset Correction: v_off_ini = -48.636 uV, v_off_fin = -32.254 uV 16:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.077 uVs 16:23:52 I2X Average and RMS of Measurements VT = -77.037 +- 2.267 uVs I2X = 7.088 +- 0.209 uTm^2 16:23:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:24:00 Integrated Voltage Measurement... 16:24:09 Voltage Offset Correction: v_off_ini = -30.300 uV, v_off_fin = -30.290 uV 16:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.980 uVs 16:24:09 Integrated Voltage Measurement... 16:24:18 Voltage Offset Correction: v_off_ini = -43.944 uV, v_off_fin = -24.212 uV 16:24:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.529 uVs 16:24:18 Integrated Voltage Measurement... 16:24:27 Voltage Offset Correction: v_off_ini = -28.723 uV, v_off_fin = -19.451 uV 16:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.750 uVs 16:24:27 Integrated Voltage Measurement... 16:24:36 Voltage Offset Correction: v_off_ini = -31.528 uV, v_off_fin = -19.235 uV 16:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.085 uVs 16:24:36 Integrated Voltage Measurement... 16:24:45 Voltage Offset Correction: v_off_ini = -22.051 uV, v_off_fin = -28.165 uV 16:24:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.036 uVs 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = -18.249 uV, v_off_fin = -18.948 uV 16:24:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.548 uVs 16:24:57 I2Y Average and RMS of Measurements VT = -295.655 +- 4.321 uVs I2Y = -27.200 +- 0.398 uTm^2 16:25:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = -18.618 uV, v_off_fin = -39.368 uV 16:25:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.505 uVs 16:25:18 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = -36.980 uV, v_off_fin = -28.717 uV 16:25:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.847 uVs 16:25:27 Integrated Voltage Measurement... 16:25:36 Voltage Offset Correction: v_off_ini = -39.808 uV, v_off_fin = -39.892 uV 16:25:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -94.528 uVs 16:25:36 Integrated Voltage Measurement... 16:25:45 Voltage Offset Correction: v_off_ini = -39.758 uV, v_off_fin = -28.424 uV 16:25:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 107.702 uVs 16:25:45 Integrated Voltage Measurement... 16:25:54 Voltage Offset Correction: v_off_ini = -19.127 uV, v_off_fin = -31.275 uV 16:25:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.822 uVs 16:25:54 Integrated Voltage Measurement... 16:26:03 Voltage Offset Correction: v_off_ini = -37.934 uV, v_off_fin = -34.953 uV 16:26:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.115 uVs 16:26:07 I1X Average and RMS of Measurements VT = -101.253 +- 6.652 uVs I1X = 20.252 +- 1.330 uTm 16:26:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = -33.641 uV, v_off_fin = -34.290 uV 16:26:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.862 uVs 16:26:23 Integrated Voltage Measurement... 16:26:32 Voltage Offset Correction: v_off_ini = -27.968 uV, v_off_fin = -17.670 uV 16:26:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.101 uVs 16:26:32 Integrated Voltage Measurement... 16:26:41 Voltage Offset Correction: v_off_ini = -29.711 uV, v_off_fin = -29.093 uV 16:26:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.718 uVs 16:26:41 Integrated Voltage Measurement... 16:26:50 Voltage Offset Correction: v_off_ini = -21.182 uV, v_off_fin = -9.405 uV 16:26:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.459 uVs 16:26:50 Integrated Voltage Measurement... 16:26:59 Voltage Offset Correction: v_off_ini = -18.589 uV, v_off_fin = -28.895 uV 16:26:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.574 uVs 16:26:59 Integrated Voltage Measurement... 16:27:08 Voltage Offset Correction: v_off_ini = -27.252 uV, v_off_fin = -12.539 uV 16:27:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.057 uVs 16:27:12 I1Y Average and RMS of Measurements VT = -203.462 +- 3.608 uVs I1Y = -40.692 +- 0.722 uTm 16:27:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:27:17 Integrated Voltage Measurement... 16:27:26 Voltage Offset Correction: v_off_ini = -29.542 uV, v_off_fin = -31.095 uV 16:27:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.021 uVs 16:27:26 Integrated Voltage Measurement... 16:27:35 Voltage Offset Correction: v_off_ini = -17.095 uV, v_off_fin = -10.103 uV 16:27:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.496 uVs 16:27:35 Integrated Voltage Measurement... 16:27:44 Voltage Offset Correction: v_off_ini = -23.245 uV, v_off_fin = -29.529 uV 16:27:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.244 uVs 16:27:44 Integrated Voltage Measurement... 16:27:53 Voltage Offset Correction: v_off_ini = -27.317 uV, v_off_fin = -9.068 uV 16:27:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.864 uVs 16:27:54 Integrated Voltage Measurement... 16:28:02 Voltage Offset Correction: v_off_ini = -18.149 uV, v_off_fin = -28.352 uV 16:28:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.257 uVs 16:28:03 Integrated Voltage Measurement... 16:28:12 Voltage Offset Correction: v_off_ini = -6.183 uV, v_off_fin = -1.141 uV 16:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.817 uVs 16:28:14 I2X Average and RMS of Measurements VT = -87.117 +- 5.117 uVs I2X = 8.015 +- 0.471 uTm^2 16:28:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:28:19 Integrated Voltage Measurement... 16:28:28 Voltage Offset Correction: v_off_ini = -10.708 uV, v_off_fin = -9.903 uV 16:28:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.360 uVs 16:28:28 Integrated Voltage Measurement... 16:28:37 Voltage Offset Correction: v_off_ini = -23.469 uV, v_off_fin = -17.785 uV 16:28:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.645 uVs 16:28:37 Integrated Voltage Measurement... 16:28:46 Voltage Offset Correction: v_off_ini = -19.177 uV, v_off_fin = -7.993 uV 16:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.534 uVs 16:28:46 Integrated Voltage Measurement... 16:28:55 Voltage Offset Correction: v_off_ini = -13.481 uV, v_off_fin = -3.652 uV 16:28:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.481 uVs 16:28:55 Integrated Voltage Measurement... 16:29:04 Voltage Offset Correction: v_off_ini = -15.747 uV, v_off_fin = -8.410 uV 16:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.089 uVs 16:29:04 Integrated Voltage Measurement... 16:29:13 Voltage Offset Correction: v_off_ini = -13.776 uV, v_off_fin = -21.498 uV 16:29:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.177 uVs 16:29:16 I2Y Average and RMS of Measurements VT = -250.048 +- 0.461 uVs I2Y = -23.004 +- 0.042 uTm^2 16:29:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:29:24 Integrated Voltage Measurement... 16:29:33 Voltage Offset Correction: v_off_ini = -13.124 uV, v_off_fin = -21.552 uV 16:29:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.364 uVs 16:29:33 Integrated Voltage Measurement... 16:29:42 Voltage Offset Correction: v_off_ini = -32.114 uV, v_off_fin = -26.713 uV 16:29:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.082 uVs 16:29:42 Integrated Voltage Measurement... 16:29:51 Voltage Offset Correction: v_off_ini = -25.932 uV, v_off_fin = -20.163 uV 16:29:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.455 uVs 16:29:51 Integrated Voltage Measurement... 16:30:00 Voltage Offset Correction: v_off_ini = -16.777 uV, v_off_fin = -5.751 uV 16:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.884 uVs 16:30:00 Integrated Voltage Measurement... 16:30:09 Voltage Offset Correction: v_off_ini = -11.470 uV, v_off_fin = -22.804 uV 16:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.347 uVs 16:30:09 Integrated Voltage Measurement... 16:30:18 Voltage Offset Correction: v_off_ini = -15.340 uV, v_off_fin = -18.401 uV 16:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.979 uVs 16:30:23 I1X Average and RMS of Measurements VT = -99.852 +- 4.721 uVs I1X = 19.970 +- 0.944 uTm 16:30:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:30:29 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = -20.479 uV, v_off_fin = -23.934 uV 16:30:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.417 uVs 16:30:38 Integrated Voltage Measurement... 16:30:47 Voltage Offset Correction: v_off_ini = -23.755 uV, v_off_fin = -9.597 uV 16:30:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.831 uVs 16:30:47 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = -20.656 uV, v_off_fin = -21.364 uV 16:30:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.914 uVs 16:30:56 Integrated Voltage Measurement... 16:31:05 Voltage Offset Correction: v_off_ini = -15.783 uV, v_off_fin = -13.787 uV 16:31:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.716 uVs 16:31:05 Integrated Voltage Measurement... 16:31:14 Voltage Offset Correction: v_off_ini = -12.607 uV, v_off_fin = -24.583 uV 16:31:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.601 uVs 16:31:14 Integrated Voltage Measurement... 16:31:23 Voltage Offset Correction: v_off_ini = -8.089 uV, v_off_fin = -4.608 uV 16:31:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.789 uVs 16:31:28 I1Y Average and RMS of Measurements VT = -197.211 +- 1.405 uVs I1Y = -39.443 +- 0.281 uTm 16:31:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:31:33 Integrated Voltage Measurement... 16:31:42 Voltage Offset Correction: v_off_ini = -18.015 uV, v_off_fin = -26.486 uV 16:31:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.796 uVs 16:31:42 Integrated Voltage Measurement... 16:31:51 Voltage Offset Correction: v_off_ini = -11.578 uV, v_off_fin = 3.625 uV 16:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.535 uVs 16:31:51 Integrated Voltage Measurement... 16:32:00 Voltage Offset Correction: v_off_ini = -3.981 uV, v_off_fin = -2.167 uV 16:32:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.718 uVs 16:32:00 Integrated Voltage Measurement... 16:32:09 Voltage Offset Correction: v_off_ini = 5.459 uV, v_off_fin = 8.033 uV 16:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.550 uVs 16:32:09 Integrated Voltage Measurement... 16:32:18 Voltage Offset Correction: v_off_ini = -9.613 uV, v_off_fin = -10.991 uV 16:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.634 uVs 16:32:18 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = 0.404 uV, v_off_fin = 6.404 uV 16:32:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.525 uVs 16:32:29 I2X Average and RMS of Measurements VT = -79.793 +- 5.105 uVs I2X = 7.341 +- 0.470 uTm^2 16:32:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:32:35 Integrated Voltage Measurement... 16:32:44 Voltage Offset Correction: v_off_ini = 4.000 uV, v_off_fin = -2.060 uV 16:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.065 uVs 16:32:44 Integrated Voltage Measurement... 16:32:53 Voltage Offset Correction: v_off_ini = 9.173 uV, v_off_fin = 1.393 uV 16:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.668 uVs 16:32:53 Integrated Voltage Measurement... 16:33:02 Voltage Offset Correction: v_off_ini = 0.565 uV, v_off_fin = -4.035 uV 16:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.806 uVs 16:33:02 Integrated Voltage Measurement... 16:33:11 Voltage Offset Correction: v_off_ini = 9.465 uV, v_off_fin = 14.806 uV 16:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.636 uVs 16:33:11 Integrated Voltage Measurement... 16:33:20 Voltage Offset Correction: v_off_ini = 6.823 uV, v_off_fin = 3.667 uV 16:33:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.069 uVs 16:33:20 Integrated Voltage Measurement... 16:33:29 Voltage Offset Correction: v_off_ini = 11.630 uV, v_off_fin = 7.240 uV 16:33:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.501 uVs 16:33:31 I2Y Average and RMS of Measurements VT = -252.124 +- 3.009 uVs I2Y = -23.195 +- 0.277 uTm^2 16:33:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:39 Integrated Voltage Measurement... 16:33:48 Voltage Offset Correction: v_off_ini = 9.753 uV, v_off_fin = -0.619 uV 16:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.064 uVs 16:33:49 Integrated Voltage Measurement... 16:33:57 Voltage Offset Correction: v_off_ini = 6.067 uV, v_off_fin = 11.358 uV 16:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.822 uVs 16:33:58 Integrated Voltage Measurement... 16:34:06 Voltage Offset Correction: v_off_ini = 16.256 uV, v_off_fin = 10.587 uV 16:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.476 uVs 16:34:07 Integrated Voltage Measurement... 16:34:16 Voltage Offset Correction: v_off_ini = 11.966 uV, v_off_fin = 4.487 uV 16:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.384 uVs 16:34:16 Integrated Voltage Measurement... 16:34:25 Voltage Offset Correction: v_off_ini = 9.695 uV, v_off_fin = 9.636 uV 16:34:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.473 uVs 16:34:25 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = 16.259 uV, v_off_fin = 7.339 uV 16:34:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.405 uVs 16:34:38 I1X Average and RMS of Measurements VT = -85.437 +- 2.545 uVs I1X = 17.088 +- 0.509 uTm 16:34:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:45 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = -1.435 uV, v_off_fin = -1.854 uV 16:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.660 uVs 16:34:54 Integrated Voltage Measurement... 16:35:02 Voltage Offset Correction: v_off_ini = 4.565 uV, v_off_fin = 28.250 uV 16:35:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.904 uVs 16:35:02 Integrated Voltage Measurement... 16:35:11 Voltage Offset Correction: v_off_ini = 7.262 uV, v_off_fin = -9.706 uV 16:35:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.808 uVs 16:35:11 Integrated Voltage Measurement... 16:35:20 Voltage Offset Correction: v_off_ini = 8.656 uV, v_off_fin = 10.861 uV 16:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.782 uVs 16:35:20 Integrated Voltage Measurement... 16:35:29 Voltage Offset Correction: v_off_ini = 25.028 uV, v_off_fin = -5.094 uV 16:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.981 uVs 16:35:29 Integrated Voltage Measurement... 16:35:38 Voltage Offset Correction: v_off_ini = 11.583 uV, v_off_fin = 25.213 uV 16:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.558 uVs 16:35:43 I1Y Average and RMS of Measurements VT = -197.116 +- 8.015 uVs I1Y = -39.423 +- 1.603 uTm 16:35:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:48 Integrated Voltage Measurement... 16:35:57 Voltage Offset Correction: v_off_ini = 6.680 uV, v_off_fin = 0.557 uV 16:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.022 uVs 16:35:57 Integrated Voltage Measurement... 16:36:06 Voltage Offset Correction: v_off_ini = 10.893 uV, v_off_fin = 29.113 uV 16:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.016 uVs 16:36:06 Integrated Voltage Measurement... 16:36:15 Voltage Offset Correction: v_off_ini = 21.448 uV, v_off_fin = 7.214 uV 16:36:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.311 uVs 16:36:15 Integrated Voltage Measurement... 16:36:24 Voltage Offset Correction: v_off_ini = 6.043 uV, v_off_fin = 17.810 uV 16:36:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.288 uVs 16:36:24 Integrated Voltage Measurement... 16:36:33 Voltage Offset Correction: v_off_ini = 13.542 uV, v_off_fin = 10.838 uV 16:36:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.321 uVs 16:36:33 Integrated Voltage Measurement... 16:36:42 Voltage Offset Correction: v_off_ini = 24.344 uV, v_off_fin = 18.768 uV 16:36:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.621 uVs 16:36:44 I2X Average and RMS of Measurements VT = -80.596 +- 3.792 uVs I2X = 7.415 +- 0.349 uTm^2 16:36:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:49 Integrated Voltage Measurement... 16:36:58 Voltage Offset Correction: v_off_ini = 1.350 uV, v_off_fin = 18.172 uV 16:36:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.698 uVs 16:36:58 Integrated Voltage Measurement... 16:37:07 Voltage Offset Correction: v_off_ini = 2.293 uV, v_off_fin = 16.714 uV 16:37:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.193 uVs 16:37:07 Integrated Voltage Measurement... 16:37:16 Voltage Offset Correction: v_off_ini = 15.181 uV, v_off_fin = 10.453 uV 16:37:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.993 uVs 16:37:16 Integrated Voltage Measurement... 16:37:25 Voltage Offset Correction: v_off_ini = 8.968 uV, v_off_fin = 2.224 uV 16:37:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.817 uVs 16:37:25 Integrated Voltage Measurement... 16:37:34 Voltage Offset Correction: v_off_ini = -1.941 uV, v_off_fin = 14.049 uV 16:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.397 uVs 16:37:34 Integrated Voltage Measurement... 16:37:43 Voltage Offset Correction: v_off_ini = 12.958 uV, v_off_fin = 30.095 uV 16:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.208 uVs 16:37:46 I2Y Average and RMS of Measurements VT = -255.218 +- 3.413 uVs I2Y = -23.480 +- 0.314 uTm^2 16:37:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:37:54 Integrated Voltage Measurement... 16:38:03 Voltage Offset Correction: v_off_ini = 10.875 uV, v_off_fin = -3.097 uV 16:38:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.791 uVs 16:38:03 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = 13.192 uV, v_off_fin = -7.697 uV 16:38:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.355 uVs 16:38:12 Integrated Voltage Measurement... 16:38:21 Voltage Offset Correction: v_off_ini = -2.781 uV, v_off_fin = -7.209 uV 16:38:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.957 uVs 16:38:21 Integrated Voltage Measurement... 16:38:30 Voltage Offset Correction: v_off_ini = -4.408 uV, v_off_fin = 7.580 uV 16:38:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.623 uVs 16:38:30 Integrated Voltage Measurement... 16:38:39 Voltage Offset Correction: v_off_ini = 11.063 uV, v_off_fin = 7.672 uV 16:38:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.617 uVs 16:38:39 Integrated Voltage Measurement... 16:38:48 Voltage Offset Correction: v_off_ini = -0.261 uV, v_off_fin = 5.480 uV 16:38:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.250 uVs 16:38:52 I1X Average and RMS of Measurements VT = -74.599 +- 6.435 uVs I1X = 14.920 +- 1.287 uTm 16:38:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:38:59 Integrated Voltage Measurement... 16:39:08 Voltage Offset Correction: v_off_ini = 10.876 uV, v_off_fin = -13.284 uV 16:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.641 uVs 16:39:08 Integrated Voltage Measurement... 16:39:17 Voltage Offset Correction: v_off_ini = -8.673 uV, v_off_fin = 5.079 uV 16:39:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.485 uVs 16:39:17 Integrated Voltage Measurement... 16:39:26 Voltage Offset Correction: v_off_ini = 2.781 uV, v_off_fin = -31.573 uV 16:39:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.115 uVs 16:39:26 Integrated Voltage Measurement... 16:39:35 Voltage Offset Correction: v_off_ini = -24.330 uV, v_off_fin = -7.293 uV 16:39:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.667 uVs 16:39:35 Integrated Voltage Measurement... 16:39:44 Voltage Offset Correction: v_off_ini = -4.829 uV, v_off_fin = -17.657 uV 16:39:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.351 uVs 16:39:44 Integrated Voltage Measurement... 16:39:53 Voltage Offset Correction: v_off_ini = -10.209 uV, v_off_fin = -5.125 uV 16:39:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.387 uVs 16:39:57 I1Y Average and RMS of Measurements VT = -205.441 +- 0.489 uVs I1Y = -41.088 +- 0.099 uTm 16:40:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:40:02 Integrated Voltage Measurement... 16:40:11 Voltage Offset Correction: v_off_ini = -10.884 uV, v_off_fin = -19.712 uV 16:40:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -47.677 uVs 16:40:11 Integrated Voltage Measurement... 16:40:20 Voltage Offset Correction: v_off_ini = -17.900 uV, v_off_fin = -9.561 uV 16:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.779 uVs 16:40:20 Integrated Voltage Measurement... 16:40:29 Voltage Offset Correction: v_off_ini = -15.640 uV, v_off_fin = -26.151 uV 16:40:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.124 uVs 16:40:29 Integrated Voltage Measurement... 16:40:38 Voltage Offset Correction: v_off_ini = -1.903 uV, v_off_fin = 0.219 uV 16:40:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.132 uVs 16:40:38 Integrated Voltage Measurement... 16:40:47 Voltage Offset Correction: v_off_ini = -17.385 uV, v_off_fin = -25.518 uV 16:40:47 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -39.893 uVs 16:40:47 Integrated Voltage Measurement... 16:40:56 Voltage Offset Correction: v_off_ini = -12.512 uV, v_off_fin = -4.818 uV 16:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.121 uVs 16:40:59 I2X Average and RMS of Measurements VT = -51.454 +- 2.957 uVs I2X = 4.734 +- 0.272 uTm^2 16:41:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:41:04 Integrated Voltage Measurement... 16:41:13 Voltage Offset Correction: v_off_ini = -11.394 uV, v_off_fin = -17.084 uV 16:41:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.428 uVs 16:41:13 Integrated Voltage Measurement... 16:41:22 Voltage Offset Correction: v_off_ini = -24.365 uV, v_off_fin = -19.341 uV 16:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.183 uVs 16:41:22 Integrated Voltage Measurement... 16:41:31 Voltage Offset Correction: v_off_ini = -16.155 uV, v_off_fin = -21.716 uV 16:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.085 uVs 16:41:31 Integrated Voltage Measurement... 16:41:40 Voltage Offset Correction: v_off_ini = -8.337 uV, v_off_fin = -16.960 uV 16:41:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.264 uVs 16:41:40 Integrated Voltage Measurement... 16:41:49 Voltage Offset Correction: v_off_ini = 0.629 uV, v_off_fin = -7.688 uV 16:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.841 uVs 16:41:49 Integrated Voltage Measurement... 16:41:58 Voltage Offset Correction: v_off_ini = -5.789 uV, v_off_fin = -9.095 uV 16:41:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.192 uVs 16:42:01 I2Y Average and RMS of Measurements VT = -261.166 +- 6.699 uVs I2Y = -24.027 +- 0.616 uTm^2 16:42:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:42:09 Integrated Voltage Measurement... 16:42:18 Voltage Offset Correction: v_off_ini = -23.004 uV, v_off_fin = -32.548 uV 16:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.282 uVs 16:42:18 Integrated Voltage Measurement... 16:42:27 Voltage Offset Correction: v_off_ini = -16.001 uV, v_off_fin = -19.173 uV 16:42:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.176 uVs 16:42:27 Integrated Voltage Measurement... 16:42:36 Voltage Offset Correction: v_off_ini = -31.454 uV, v_off_fin = -35.013 uV 16:42:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.158 uVs 16:42:36 Integrated Voltage Measurement... 16:42:45 Voltage Offset Correction: v_off_ini = -34.155 uV, v_off_fin = -28.796 uV 16:42:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.106 uVs 16:42:45 Integrated Voltage Measurement... 16:42:54 Voltage Offset Correction: v_off_ini = -29.089 uV, v_off_fin = -44.956 uV 16:42:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.213 uVs 16:42:54 Integrated Voltage Measurement... 16:43:03 Voltage Offset Correction: v_off_ini = -42.261 uV, v_off_fin = -32.990 uV 16:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.342 uVs 16:43:07 I1X Average and RMS of Measurements VT = -61.879 +- 0.563 uVs I1X = 12.376 +- 0.112 uTm 16:43:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:43:14 Integrated Voltage Measurement... 16:43:23 Voltage Offset Correction: v_off_ini = -33.952 uV, v_off_fin = -45.768 uV 16:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.286 uVs 16:43:23 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = -39.878 uV, v_off_fin = -36.230 uV 16:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.877 uVs 16:43:32 Integrated Voltage Measurement... 16:43:41 Voltage Offset Correction: v_off_ini = -38.577 uV, v_off_fin = -54.110 uV 16:43:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.314 uVs 16:43:41 Integrated Voltage Measurement... 16:43:50 Voltage Offset Correction: v_off_ini = -39.406 uV, v_off_fin = -30.906 uV 16:43:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.338 uVs 16:43:50 Integrated Voltage Measurement... 16:43:59 Voltage Offset Correction: v_off_ini = -46.201 uV, v_off_fin = -63.191 uV 16:43:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.262 uVs 16:43:59 Integrated Voltage Measurement... 16:44:08 Voltage Offset Correction: v_off_ini = -43.131 uV, v_off_fin = -33.001 uV 16:44:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.040 uVs 16:44:12 I1Y Average and RMS of Measurements VT = -198.853 +- 4.048 uVs I1Y = -39.770 +- 0.811 uTm 16:44:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:44:17 Integrated Voltage Measurement... 16:44:26 Voltage Offset Correction: v_off_ini = -41.968 uV, v_off_fin = -49.564 uV 16:44:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -55.428 uVs 16:44:26 Integrated Voltage Measurement... 16:44:35 Voltage Offset Correction: v_off_ini = -41.073 uV, v_off_fin = -37.108 uV 16:44:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.667 uVs 16:44:35 Integrated Voltage Measurement... 16:44:44 Voltage Offset Correction: v_off_ini = -57.876 uV, v_off_fin = -60.606 uV 16:44:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -34.621 uVs 16:44:44 Integrated Voltage Measurement... 16:44:53 Voltage Offset Correction: v_off_ini = -48.179 uV, v_off_fin = -45.615 uV 16:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.815 uVs 16:44:54 Integrated Voltage Measurement... 16:45:02 Voltage Offset Correction: v_off_ini = -56.258 uV, v_off_fin = -65.244 uV 16:45:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.239 uVs 16:45:03 Integrated Voltage Measurement... 16:45:12 Voltage Offset Correction: v_off_ini = -52.671 uV, v_off_fin = -49.061 uV 16:45:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.448 uVs 16:45:14 I2X Average and RMS of Measurements VT = -41.203 +- 4.374 uVs I2X = 3.791 +- 0.402 uTm^2 16:45:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:45:19 Integrated Voltage Measurement... 16:45:28 Voltage Offset Correction: v_off_ini = -42.575 uV, v_off_fin = -43.247 uV 16:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.693 uVs 16:45:28 Integrated Voltage Measurement... 16:45:37 Voltage Offset Correction: v_off_ini = -31.386 uV, v_off_fin = -37.591 uV 16:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.800 uVs 16:45:37 Integrated Voltage Measurement... 16:45:46 Voltage Offset Correction: v_off_ini = -39.002 uV, v_off_fin = -53.857 uV 16:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.984 uVs 16:45:46 Integrated Voltage Measurement... 16:45:55 Voltage Offset Correction: v_off_ini = -67.685 uV, v_off_fin = -53.487 uV 16:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.221 uVs 16:45:55 Integrated Voltage Measurement... 16:46:04 Voltage Offset Correction: v_off_ini = -40.360 uV, v_off_fin = -42.063 uV 16:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.086 uVs 16:46:04 Integrated Voltage Measurement... 16:46:13 Voltage Offset Correction: v_off_ini = -36.101 uV, v_off_fin = -53.634 uV 16:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.312 uVs 16:46:16 I2Y Average and RMS of Measurements VT = -263.516 +- 3.271 uVs I2Y = -24.243 +- 0.301 uTm^2 16:46:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:46:37 Integrated Voltage Measurement... 16:46:46 Voltage Offset Correction: v_off_ini = -13.205 uV, v_off_fin = -39.945 uV 16:46:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.693 uVs 16:46:46 Integrated Voltage Measurement... 16:46:55 Voltage Offset Correction: v_off_ini = -45.089 uV, v_off_fin = -37.722 uV 16:46:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.373 uVs 16:46:55 Integrated Voltage Measurement... 16:47:04 Voltage Offset Correction: v_off_ini = -47.055 uV, v_off_fin = -46.281 uV 16:47:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.514 uVs 16:47:04 Integrated Voltage Measurement... 16:47:13 Voltage Offset Correction: v_off_ini = -42.938 uV, v_off_fin = -37.988 uV 16:47:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.693 uVs 16:47:13 Integrated Voltage Measurement... 16:47:22 Voltage Offset Correction: v_off_ini = -60.966 uV, v_off_fin = -56.203 uV 16:47:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.578 uVs 16:47:22 Integrated Voltage Measurement... 16:47:31 Voltage Offset Correction: v_off_ini = -72.313 uV, v_off_fin = -53.596 uV 16:47:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.649 uVs 16:47:35 I1X Average and RMS of Measurements VT = -99.583 +- 3.208 uVs I1X = 19.917 +- 0.642 uTm 16:47:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:47:42 Integrated Voltage Measurement... 16:47:51 Voltage Offset Correction: v_off_ini = -54.485 uV, v_off_fin = -57.887 uV 16:47:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.314 uVs 16:47:51 Integrated Voltage Measurement... 16:48:00 Voltage Offset Correction: v_off_ini = -59.524 uV, v_off_fin = -42.449 uV 16:48:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.613 uVs 16:48:00 Integrated Voltage Measurement... 16:48:09 Voltage Offset Correction: v_off_ini = -36.306 uV, v_off_fin = -42.539 uV 16:48:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.822 uVs 16:48:09 Integrated Voltage Measurement... 16:48:18 Voltage Offset Correction: v_off_ini = -38.272 uV, v_off_fin = -44.261 uV 16:48:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.666 uVs 16:48:18 Integrated Voltage Measurement... 16:48:27 Voltage Offset Correction: v_off_ini = -45.345 uV, v_off_fin = -46.226 uV 16:48:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.545 uVs 16:48:27 Integrated Voltage Measurement... 16:48:36 Voltage Offset Correction: v_off_ini = -35.742 uV, v_off_fin = -33.723 uV 16:48:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.386 uVs 16:48:40 I1Y Average and RMS of Measurements VT = -166.558 +- 5.858 uVs I1Y = -33.312 +- 1.172 uTm 16:48:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:48:48 Integrated Voltage Measurement... 16:48:57 Voltage Offset Correction: v_off_ini = -33.177 uV, v_off_fin = -33.183 uV 16:48:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.762 uVs 16:48:57 Integrated Voltage Measurement... 16:49:06 Voltage Offset Correction: v_off_ini = -39.053 uV, v_off_fin = -25.042 uV 16:49:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.651 uVs 16:49:06 Integrated Voltage Measurement... 16:49:15 Voltage Offset Correction: v_off_ini = -31.115 uV, v_off_fin = -36.740 uV 16:49:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.070 uVs 16:49:15 Integrated Voltage Measurement... 16:49:24 Voltage Offset Correction: v_off_ini = -31.784 uV, v_off_fin = -21.421 uV 16:49:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.283 uVs 16:49:24 Integrated Voltage Measurement... 16:49:33 Voltage Offset Correction: v_off_ini = -36.325 uV, v_off_fin = -40.377 uV 16:49:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.750 uVs 16:49:33 Integrated Voltage Measurement... 16:49:42 Voltage Offset Correction: v_off_ini = -37.244 uV, v_off_fin = -18.778 uV 16:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.935 uVs 16:49:45 I2X Average and RMS of Measurements VT = -81.409 +- 0.501 uVs I2X = 7.490 +- 0.046 uTm^2 16:49:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:49:52 Integrated Voltage Measurement... 16:50:01 Voltage Offset Correction: v_off_ini = -12.494 uV, v_off_fin = -21.034 uV 16:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.390 uVs 16:50:01 Integrated Voltage Measurement... 16:50:10 Voltage Offset Correction: v_off_ini = -16.456 uV, v_off_fin = -21.426 uV 16:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.977 uVs 16:50:10 Integrated Voltage Measurement... 16:50:19 Voltage Offset Correction: v_off_ini = -17.813 uV, v_off_fin = -22.887 uV 16:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.413 uVs 16:50:19 Integrated Voltage Measurement... 16:50:28 Voltage Offset Correction: v_off_ini = -19.613 uV, v_off_fin = -22.709 uV 16:50:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.598 uVs 16:50:29 Integrated Voltage Measurement... 16:50:38 Voltage Offset Correction: v_off_ini = -15.330 uV, v_off_fin = -18.192 uV 16:50:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.551 uVs 16:50:38 Integrated Voltage Measurement... 16:50:47 Voltage Offset Correction: v_off_ini = -15.611 uV, v_off_fin = -9.059 uV 16:50:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.678 uVs 16:50:49 I2Y Average and RMS of Measurements VT = -208.935 +- 2.706 uVs I2Y = -19.222 +- 0.249 uTm^2 16:50:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:50:58 Integrated Voltage Measurement... 16:51:07 Voltage Offset Correction: v_off_ini = -19.056 uV, v_off_fin = -4.823 uV 16:51:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.722 uVs 16:51:07 Integrated Voltage Measurement... 16:51:16 Voltage Offset Correction: v_off_ini = -9.915 uV, v_off_fin = -10.994 uV 16:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.867 uVs 16:51:16 Integrated Voltage Measurement... 16:51:25 Voltage Offset Correction: v_off_ini = -8.204 uV, v_off_fin = -15.551 uV 16:51:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.247 uVs 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = -8.244 uV, v_off_fin = -22.558 uV 16:51:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.680 uVs 16:51:34 Integrated Voltage Measurement... 16:51:43 Voltage Offset Correction: v_off_ini = -24.813 uV, v_off_fin = -25.109 uV 16:51:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.779 uVs 16:51:43 Integrated Voltage Measurement... 16:51:52 Voltage Offset Correction: v_off_ini = -29.620 uV, v_off_fin = -18.428 uV 16:51:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.995 uVs 16:51:56 I1X Average and RMS of Measurements VT = -103.215 +- 7.039 uVs I1X = 20.643 +- 1.408 uTm 16:51:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:52:03 Integrated Voltage Measurement... 16:52:12 Voltage Offset Correction: v_off_ini = -27.522 uV, v_off_fin = -31.286 uV 16:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.470 uVs 16:52:12 Integrated Voltage Measurement... 16:52:21 Voltage Offset Correction: v_off_ini = -29.930 uV, v_off_fin = -32.328 uV 16:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.710 uVs 16:52:21 Integrated Voltage Measurement... 16:52:30 Voltage Offset Correction: v_off_ini = -38.106 uV, v_off_fin = -52.621 uV 16:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.143 uVs 16:52:30 Integrated Voltage Measurement... 16:52:39 Voltage Offset Correction: v_off_ini = -31.597 uV, v_off_fin = -18.502 uV 16:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.107 uVs 16:52:39 Integrated Voltage Measurement... 16:52:48 Voltage Offset Correction: v_off_ini = -24.095 uV, v_off_fin = -44.325 uV 16:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.339 uVs 16:52:48 Integrated Voltage Measurement... 16:52:57 Voltage Offset Correction: v_off_ini = -45.480 uV, v_off_fin = -31.821 uV 16:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.837 uVs 16:53:01 I1Y Average and RMS of Measurements VT = -190.101 +- 5.088 uVs I1Y = -38.020 +- 1.018 uTm 16:53:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:53:09 Integrated Voltage Measurement... 16:53:18 Voltage Offset Correction: v_off_ini = -54.549 uV, v_off_fin = -61.552 uV 16:53:18 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -81.899 uVs 16:53:18 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = -47.240 uV, v_off_fin = -35.263 uV 16:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.005 uVs 16:53:27 Integrated Voltage Measurement... 16:53:36 Voltage Offset Correction: v_off_ini = -46.772 uV, v_off_fin = -67.800 uV 16:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.479 uVs 16:53:36 Integrated Voltage Measurement... 16:53:45 Voltage Offset Correction: v_off_ini = -50.137 uV, v_off_fin = -54.578 uV 16:53:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.996 uVs 16:53:45 Integrated Voltage Measurement... 16:53:54 Voltage Offset Correction: v_off_ini = -64.272 uV, v_off_fin = -81.414 uV 16:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.693 uVs 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = -69.411 uV, v_off_fin = -61.359 uV 16:54:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.933 uVs 16:54:06 I2X Average and RMS of Measurements VT = -86.168 +- 7.466 uVs I2X = 7.927 +- 0.687 uTm^2 16:54:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:54:13 Integrated Voltage Measurement... 16:54:22 Voltage Offset Correction: v_off_ini = -63.925 uV, v_off_fin = -63.407 uV 16:54:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.345 uVs 16:54:22 Integrated Voltage Measurement... 16:54:31 Voltage Offset Correction: v_off_ini = -68.401 uV, v_off_fin = -56.249 uV 16:54:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.040 uVs 16:54:31 Integrated Voltage Measurement... 16:54:40 Voltage Offset Correction: v_off_ini = -62.540 uV, v_off_fin = -60.505 uV 16:54:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.902 uVs 16:54:40 Integrated Voltage Measurement... 16:54:49 Voltage Offset Correction: v_off_ini = -77.816 uV, v_off_fin = -81.882 uV 16:54:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.861 uVs 16:54:49 Integrated Voltage Measurement... 16:54:58 Voltage Offset Correction: v_off_ini = -81.064 uV, v_off_fin = -71.331 uV 16:54:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.037 uVs 16:54:58 Integrated Voltage Measurement... 16:55:07 Voltage Offset Correction: v_off_ini = -83.805 uV, v_off_fin = -79.900 uV 16:55:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.925 uVs 16:55:10 I2Y Average and RMS of Measurements VT = -232.018 +- 7.717 uVs I2Y = -21.346 +- 0.710 uTm^2 16:55:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:19 Integrated Voltage Measurement... 16:55:28 Voltage Offset Correction: v_off_ini = -79.095 uV, v_off_fin = -72.303 uV 16:55:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.690 uVs 16:55:28 Integrated Voltage Measurement... 16:55:37 Voltage Offset Correction: v_off_ini = -74.369 uV, v_off_fin = -62.127 uV 16:55:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.355 uVs 16:55:37 Integrated Voltage Measurement... 16:55:46 Voltage Offset Correction: v_off_ini = -60.184 uV, v_off_fin = -64.972 uV 16:55:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.503 uVs 16:55:46 Integrated Voltage Measurement... 16:55:55 Voltage Offset Correction: v_off_ini = -47.894 uV, v_off_fin = -48.162 uV 16:55:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 86.662 uVs 16:55:55 Integrated Voltage Measurement... 16:56:04 Voltage Offset Correction: v_off_ini = -58.948 uV, v_off_fin = -58.257 uV 16:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.862 uVs 16:56:04 Integrated Voltage Measurement... 16:56:13 Voltage Offset Correction: v_off_ini = -49.512 uV, v_off_fin = -53.365 uV 16:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.863 uVs 16:56:17 I1X Average and RMS of Measurements VT = -99.656 +- 5.715 uVs I1X = 19.932 +- 1.142 uTm 16:56:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:24 Integrated Voltage Measurement... 16:56:33 Voltage Offset Correction: v_off_ini = -43.670 uV, v_off_fin = -66.414 uV 16:56:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.648 uVs 16:56:33 Integrated Voltage Measurement... 16:56:42 Voltage Offset Correction: v_off_ini = -57.393 uV, v_off_fin = -46.018 uV 16:56:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.902 uVs 16:56:42 Integrated Voltage Measurement... 16:56:51 Voltage Offset Correction: v_off_ini = -65.513 uV, v_off_fin = -61.640 uV 16:56:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.208 uVs 16:56:51 Integrated Voltage Measurement... 16:57:00 Voltage Offset Correction: v_off_ini = -69.492 uV, v_off_fin = -49.662 uV 16:57:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.512 uVs 16:57:00 Integrated Voltage Measurement... 16:57:09 Voltage Offset Correction: v_off_ini = -66.538 uV, v_off_fin = -71.225 uV 16:57:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.989 uVs 16:57:09 Integrated Voltage Measurement... 16:57:18 Voltage Offset Correction: v_off_ini = -62.322 uV, v_off_fin = -67.739 uV 16:57:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.866 uVs 16:57:22 I1Y Average and RMS of Measurements VT = -206.854 +- 2.886 uVs I1Y = -41.371 +- 0.577 uTm 16:57:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:30 Integrated Voltage Measurement... 16:57:39 Voltage Offset Correction: v_off_ini = -58.863 uV, v_off_fin = -66.165 uV 16:57:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.062 uVs 16:57:39 Integrated Voltage Measurement... 16:57:48 Voltage Offset Correction: v_off_ini = -56.750 uV, v_off_fin = -35.354 uV 16:57:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.745 uVs 16:57:48 Integrated Voltage Measurement... 16:57:57 Voltage Offset Correction: v_off_ini = -45.521 uV, v_off_fin = -46.664 uV 16:57:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.165 uVs 16:57:57 Integrated Voltage Measurement... 16:58:06 Voltage Offset Correction: v_off_ini = -37.612 uV, v_off_fin = -39.625 uV 16:58:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.659 uVs 16:58:06 Integrated Voltage Measurement... 16:58:15 Voltage Offset Correction: v_off_ini = -50.874 uV, v_off_fin = -56.570 uV 16:58:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.481 uVs 16:58:15 Integrated Voltage Measurement... 16:58:24 Voltage Offset Correction: v_off_ini = -49.931 uV, v_off_fin = -50.063 uV 16:58:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.743 uVs 16:58:26 I2X Average and RMS of Measurements VT = -92.142 +- 10.076 uVs I2X = 8.477 +- 0.927 uTm^2 16:58:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:58:34 Integrated Voltage Measurement... 16:58:43 Voltage Offset Correction: v_off_ini = -59.707 uV, v_off_fin = -51.745 uV 16:58:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.693 uVs 16:58:43 Integrated Voltage Measurement... 16:58:52 Voltage Offset Correction: v_off_ini = -47.686 uV, v_off_fin = -39.871 uV 16:58:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.589 uVs 16:58:52 Integrated Voltage Measurement... 16:59:01 Voltage Offset Correction: v_off_ini = -45.548 uV, v_off_fin = -32.724 uV 16:59:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.885 uVs 16:59:01 Integrated Voltage Measurement... 16:59:10 Voltage Offset Correction: v_off_ini = -27.672 uV, v_off_fin = -30.319 uV 16:59:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.886 uVs 16:59:10 Integrated Voltage Measurement... 16:59:19 Voltage Offset Correction: v_off_ini = -61.341 uV, v_off_fin = -52.294 uV 16:59:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.644 uVs 16:59:19 Integrated Voltage Measurement... 16:59:28 Voltage Offset Correction: v_off_ini = -50.235 uV, v_off_fin = -44.898 uV 16:59:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 255.735 uVs 16:59:31 I2Y Average and RMS of Measurements VT = -251.739 +- 1.912 uVs I2Y = -23.160 +- 0.176 uTm^2 16:59:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:59:40 Integrated Voltage Measurement... 16:59:49 Voltage Offset Correction: v_off_ini = -36.708 uV, v_off_fin = -54.947 uV 16:59:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.705 uVs 16:59:49 Integrated Voltage Measurement... 16:59:58 Voltage Offset Correction: v_off_ini = -48.214 uV, v_off_fin = -35.265 uV 16:59:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 107.870 uVs 16:59:58 Integrated Voltage Measurement... 17:00:07 Voltage Offset Correction: v_off_ini = -31.741 uV, v_off_fin = -34.250 uV 17:00:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.958 uVs 17:00:07 Integrated Voltage Measurement... 17:00:16 Voltage Offset Correction: v_off_ini = -47.687 uV, v_off_fin = -47.994 uV 17:00:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.539 uVs 17:00:16 Integrated Voltage Measurement... 17:00:25 Voltage Offset Correction: v_off_ini = -38.866 uV, v_off_fin = -43.940 uV 17:00:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.895 uVs 17:00:25 Integrated Voltage Measurement... 17:00:34 Voltage Offset Correction: v_off_ini = -37.696 uV, v_off_fin = -32.730 uV 17:00:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.976 uVs 17:00:38 I1X Average and RMS of Measurements VT = -112.324 +- 5.231 uVs I1X = 22.466 +- 1.046 uTm 17:00:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:00:45 Integrated Voltage Measurement... 17:00:54 Voltage Offset Correction: v_off_ini = -32.214 uV, v_off_fin = -47.520 uV 17:00:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.094 uVs 17:00:54 Integrated Voltage Measurement... 17:01:03 Voltage Offset Correction: v_off_ini = -36.531 uV, v_off_fin = -39.318 uV 17:01:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.292 uVs 17:01:03 Integrated Voltage Measurement... 17:01:12 Voltage Offset Correction: v_off_ini = -54.670 uV, v_off_fin = -57.069 uV 17:01:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.909 uVs 17:01:12 Integrated Voltage Measurement... 17:01:21 Voltage Offset Correction: v_off_ini = -42.012 uV, v_off_fin = -28.109 uV 17:01:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.668 uVs 17:01:21 Integrated Voltage Measurement... 17:01:30 Voltage Offset Correction: v_off_ini = -36.577 uV, v_off_fin = -41.584 uV 17:01:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.404 uVs 17:01:30 Integrated Voltage Measurement... 17:01:39 Voltage Offset Correction: v_off_ini = -40.084 uV, v_off_fin = -32.154 uV 17:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.681 uVs 17:01:43 I1Y Average and RMS of Measurements VT = -227.341 +- 1.765 uVs I1Y = -45.468 +- 0.353 uTm 17:01:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:01:51 Integrated Voltage Measurement... 17:02:00 Voltage Offset Correction: v_off_ini = -32.897 uV, v_off_fin = -53.679 uV 17:02:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.018 uVs 17:02:00 Integrated Voltage Measurement... 17:02:09 Voltage Offset Correction: v_off_ini = -48.287 uV, v_off_fin = -29.251 uV 17:02:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.319 uVs 17:02:09 Integrated Voltage Measurement... 17:02:18 Voltage Offset Correction: v_off_ini = -38.834 uV, v_off_fin = -47.721 uV 17:02:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.339 uVs 17:02:18 Integrated Voltage Measurement... 17:02:27 Voltage Offset Correction: v_off_ini = -55.132 uV, v_off_fin = -53.317 uV 17:02:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.361 uVs 17:02:27 Integrated Voltage Measurement... 17:02:36 Voltage Offset Correction: v_off_ini = -48.010 uV, v_off_fin = -73.943 uV 17:02:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.882 uVs 17:02:36 Integrated Voltage Measurement... 17:02:45 Voltage Offset Correction: v_off_ini = -63.910 uV, v_off_fin = -53.223 uV 17:02:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.418 uVs 17:02:47 I2X Average and RMS of Measurements VT = -95.223 +- 10.218 uVs I2X = 8.760 +- 0.940 uTm^2 17:02:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:02:55 Integrated Voltage Measurement... 17:03:04 Voltage Offset Correction: v_off_ini = -37.244 uV, v_off_fin = -50.873 uV 17:03:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.555 uVs 17:03:04 Integrated Voltage Measurement... 17:03:13 Voltage Offset Correction: v_off_ini = -55.406 uV, v_off_fin = -61.305 uV 17:03:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.984 uVs 17:03:13 Integrated Voltage Measurement... 17:03:22 Voltage Offset Correction: v_off_ini = -67.616 uV, v_off_fin = -66.834 uV 17:03:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.089 uVs 17:03:22 Integrated Voltage Measurement... 17:03:31 Voltage Offset Correction: v_off_ini = -72.618 uV, v_off_fin = -64.317 uV 17:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.516 uVs 17:03:31 Integrated Voltage Measurement... 17:03:40 Voltage Offset Correction: v_off_ini = -48.054 uV, v_off_fin = -55.887 uV 17:03:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.907 uVs 17:03:40 Integrated Voltage Measurement... 17:03:49 Voltage Offset Correction: v_off_ini = -56.503 uV, v_off_fin = -59.306 uV 17:03:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.340 uVs 17:03:52 I2Y Average and RMS of Measurements VT = -272.065 +- 5.565 uVs I2Y = -25.030 +- 0.512 uTm^2 17:03:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:04:01 Integrated Voltage Measurement... 17:04:10 Voltage Offset Correction: v_off_ini = -57.499 uV, v_off_fin = -64.414 uV 17:04:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.518 uVs 17:04:10 Integrated Voltage Measurement... 17:04:19 Voltage Offset Correction: v_off_ini = -49.932 uV, v_off_fin = -50.620 uV 17:04:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.487 uVs 17:04:19 Integrated Voltage Measurement... 17:04:28 Voltage Offset Correction: v_off_ini = -62.213 uV, v_off_fin = -68.484 uV 17:04:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.913 uVs 17:04:28 Integrated Voltage Measurement... 17:04:37 Voltage Offset Correction: v_off_ini = -62.457 uV, v_off_fin = -57.331 uV 17:04:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.624 uVs 17:04:37 Integrated Voltage Measurement... 17:04:46 Voltage Offset Correction: v_off_ini = -57.959 uV, v_off_fin = -63.407 uV 17:04:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.228 uVs 17:04:46 Integrated Voltage Measurement... 17:04:55 Voltage Offset Correction: v_off_ini = -76.484 uV, v_off_fin = -63.708 uV 17:04:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.547 uVs 17:04:59 I1X Average and RMS of Measurements VT = -107.719 +- 9.386 uVs I1X = 21.544 +- 1.877 uTm 17:05:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:05:06 Integrated Voltage Measurement... 17:05:15 Voltage Offset Correction: v_off_ini = -68.239 uV, v_off_fin = -87.633 uV 17:05:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.645 uVs 17:05:15 Integrated Voltage Measurement... 17:05:24 Voltage Offset Correction: v_off_ini = -66.674 uV, v_off_fin = -63.958 uV 17:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.857 uVs 17:05:24 Integrated Voltage Measurement... 17:05:33 Voltage Offset Correction: v_off_ini = -65.632 uV, v_off_fin = -79.833 uV 17:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.396 uVs 17:05:33 Integrated Voltage Measurement... 17:05:42 Voltage Offset Correction: v_off_ini = -51.408 uV, v_off_fin = -58.649 uV 17:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.954 uVs 17:05:42 Integrated Voltage Measurement... 17:05:51 Voltage Offset Correction: v_off_ini = -53.418 uV, v_off_fin = -63.021 uV 17:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.329 uVs 17:05:51 Integrated Voltage Measurement... 17:06:00 Voltage Offset Correction: v_off_ini = -55.325 uV, v_off_fin = -64.234 uV 17:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.251 uVs 17:06:04 I1Y Average and RMS of Measurements VT = -236.239 +- 6.909 uVs I1Y = -47.248 +- 1.382 uTm 17:06:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:06:12 Integrated Voltage Measurement... 17:06:21 Voltage Offset Correction: v_off_ini = -78.316 uV, v_off_fin = -80.624 uV 17:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.557 uVs 17:06:21 Integrated Voltage Measurement... 17:06:30 Voltage Offset Correction: v_off_ini = -73.615 uV, v_off_fin = -52.838 uV 17:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.921 uVs 17:06:30 Integrated Voltage Measurement... 17:06:39 Voltage Offset Correction: v_off_ini = -80.694 uV, v_off_fin = -76.013 uV 17:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.180 uVs 17:06:39 Integrated Voltage Measurement... 17:06:48 Voltage Offset Correction: v_off_ini = -55.719 uV, v_off_fin = -56.628 uV 17:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.990 uVs 17:06:48 Integrated Voltage Measurement... 17:06:57 Voltage Offset Correction: v_off_ini = -59.321 uV, v_off_fin = -61.096 uV 17:06:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.395 uVs 17:06:57 Integrated Voltage Measurement... 17:07:06 Voltage Offset Correction: v_off_ini = -57.516 uV, v_off_fin = -41.795 uV 17:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.769 uVs 17:07:08 I2X Average and RMS of Measurements VT = -100.969 +- 6.955 uVs I2X = 9.289 +- 0.640 uTm^2 17:07:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:07:16 Integrated Voltage Measurement... 17:07:25 Voltage Offset Correction: v_off_ini = -36.294 uV, v_off_fin = -43.929 uV 17:07:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.261 uVs 17:07:25 Integrated Voltage Measurement... 17:07:34 Voltage Offset Correction: v_off_ini = -65.125 uV, v_off_fin = -55.088 uV 17:07:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.103 uVs 17:07:34 Integrated Voltage Measurement... 17:07:43 Voltage Offset Correction: v_off_ini = -75.973 uV, v_off_fin = -56.245 uV 17:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.918 uVs 17:07:43 Integrated Voltage Measurement... 17:07:52 Voltage Offset Correction: v_off_ini = -57.702 uV, v_off_fin = -52.858 uV 17:07:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.199 uVs 17:07:52 Integrated Voltage Measurement... 17:08:01 Voltage Offset Correction: v_off_ini = -47.605 uV, v_off_fin = -40.954 uV 17:08:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.789 uVs 17:08:01 Integrated Voltage Measurement... 17:08:10 Voltage Offset Correction: v_off_ini = -42.246 uV, v_off_fin = -43.383 uV 17:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.753 uVs 17:08:13 I2Y Average and RMS of Measurements VT = -288.504 +- 9.104 uVs I2Y = -26.542 +- 0.838 uTm^2 17:08:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:08:25 Integrated Voltage Measurement... 17:08:34 Voltage Offset Correction: v_off_ini = -46.326 uV, v_off_fin = -60.288 uV 17:08:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.664 uVs 17:08:34 Integrated Voltage Measurement... 17:08:43 Voltage Offset Correction: v_off_ini = -48.686 uV, v_off_fin = -52.421 uV 17:08:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.666 uVs 17:08:43 Integrated Voltage Measurement... 17:08:52 Voltage Offset Correction: v_off_ini = -62.158 uV, v_off_fin = -57.405 uV 17:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.847 uVs 17:08:52 Integrated Voltage Measurement... 17:09:01 Voltage Offset Correction: v_off_ini = -62.512 uV, v_off_fin = -55.096 uV 17:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.552 uVs 17:09:01 Integrated Voltage Measurement... 17:09:10 Voltage Offset Correction: v_off_ini = -52.776 uV, v_off_fin = -60.931 uV 17:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.363 uVs 17:09:10 Integrated Voltage Measurement... 17:09:19 Voltage Offset Correction: v_off_ini = -61.928 uV, v_off_fin = -61.348 uV 17:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.222 uVs 17:09:23 I1X Average and RMS of Measurements VT = -114.719 +- 2.317 uVs I1X = 22.944 +- 0.463 uTm 17:09:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:09:30 Integrated Voltage Measurement... 17:09:39 Voltage Offset Correction: v_off_ini = -53.298 uV, v_off_fin = -65.780 uV 17:09:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -204.840 uVs 17:09:39 Integrated Voltage Measurement... 17:09:48 Voltage Offset Correction: v_off_ini = -63.387 uV, v_off_fin = -44.595 uV 17:09:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.900 uVs 17:09:48 Integrated Voltage Measurement... 17:09:57 Voltage Offset Correction: v_off_ini = -48.154 uV, v_off_fin = -62.596 uV 17:09:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.036 uVs 17:09:57 Integrated Voltage Measurement... 17:10:06 Voltage Offset Correction: v_off_ini = -53.857 uV, v_off_fin = -55.285 uV 17:10:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.531 uVs 17:10:06 Integrated Voltage Measurement... 17:10:15 Voltage Offset Correction: v_off_ini = -56.918 uV, v_off_fin = -69.272 uV 17:10:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.133 uVs 17:10:15 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = -66.017 uV, v_off_fin = -50.946 uV 17:10:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.136 uVs 17:10:28 I1Y Average and RMS of Measurements VT = -204.096 +- 2.281 uVs I1Y = -40.820 +- 0.457 uTm 17:10:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:10:33 Integrated Voltage Measurement... 17:10:42 Voltage Offset Correction: v_off_ini = -62.846 uV, v_off_fin = -72.667 uV 17:10:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -107.408 uVs 17:10:42 Integrated Voltage Measurement... 17:10:51 Voltage Offset Correction: v_off_ini = -67.122 uV, v_off_fin = -49.125 uV 17:10:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.598 uVs 17:10:51 Integrated Voltage Measurement... 17:11:00 Voltage Offset Correction: v_off_ini = -50.322 uV, v_off_fin = -59.334 uV 17:11:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.562 uVs 17:11:00 Integrated Voltage Measurement... 17:11:09 Voltage Offset Correction: v_off_ini = -59.015 uV, v_off_fin = -53.797 uV 17:11:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.446 uVs 17:11:09 Integrated Voltage Measurement... 17:11:18 Voltage Offset Correction: v_off_ini = -58.679 uV, v_off_fin = -66.139 uV 17:11:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -112.818 uVs 17:11:18 Integrated Voltage Measurement... 17:11:27 Voltage Offset Correction: v_off_ini = -57.615 uV, v_off_fin = -38.834 uV 17:11:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.492 uVs 17:11:30 I2X Average and RMS of Measurements VT = -108.721 +- 7.746 uVs I2X = 10.002 +- 0.713 uTm^2 17:11:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:11:35 Integrated Voltage Measurement... 17:11:44 Voltage Offset Correction: v_off_ini = -70.381 uV, v_off_fin = -65.009 uV 17:11:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.911 uVs 17:11:44 Integrated Voltage Measurement... 17:11:53 Voltage Offset Correction: v_off_ini = -82.248 uV, v_off_fin = -62.318 uV 17:11:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.300 uVs 17:11:53 Integrated Voltage Measurement... 17:12:02 Voltage Offset Correction: v_off_ini = -60.982 uV, v_off_fin = -54.496 uV 17:12:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -260.372 uVs 17:12:02 Integrated Voltage Measurement... 17:12:11 Voltage Offset Correction: v_off_ini = -55.277 uV, v_off_fin = -57.797 uV 17:12:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.205 uVs 17:12:11 Integrated Voltage Measurement... 17:12:20 Voltage Offset Correction: v_off_ini = -69.788 uV, v_off_fin = -72.030 uV 17:12:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.860 uVs 17:12:20 Integrated Voltage Measurement... 17:12:29 Voltage Offset Correction: v_off_ini = -68.180 uV, v_off_fin = -69.146 uV 17:12:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.009 uVs 17:12:32 I2Y Average and RMS of Measurements VT = -252.443 +- 10.794 uVs I2Y = -23.225 +- 0.993 uTm^2 17:12:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:12:40 Integrated Voltage Measurement... 17:12:49 Voltage Offset Correction: v_off_ini = -61.227 uV, v_off_fin = -73.692 uV 17:12:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.294 uVs 17:12:49 Integrated Voltage Measurement... 17:12:58 Voltage Offset Correction: v_off_ini = -67.291 uV, v_off_fin = -57.890 uV 17:12:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.298 uVs 17:12:58 Integrated Voltage Measurement... 17:13:07 Voltage Offset Correction: v_off_ini = -79.849 uV, v_off_fin = -58.975 uV 17:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.991 uVs 17:13:07 Integrated Voltage Measurement... 17:13:16 Voltage Offset Correction: v_off_ini = -54.462 uV, v_off_fin = -51.274 uV 17:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.410 uVs 17:13:16 Integrated Voltage Measurement... 17:13:25 Voltage Offset Correction: v_off_ini = -52.360 uV, v_off_fin = -64.547 uV 17:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.997 uVs 17:13:25 Integrated Voltage Measurement... 17:13:34 Voltage Offset Correction: v_off_ini = -47.823 uV, v_off_fin = -56.340 uV 17:13:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.995 uVs 17:13:38 I1X Average and RMS of Measurements VT = -107.498 +- 14.411 uVs I1X = 21.500 +- 2.882 uTm 17:13:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:13:45 Integrated Voltage Measurement... 17:13:54 Voltage Offset Correction: v_off_ini = -79.343 uV, v_off_fin = -87.053 uV 17:13:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.496 uVs 17:13:54 Integrated Voltage Measurement... 17:14:03 Voltage Offset Correction: v_off_ini = -82.573 uV, v_off_fin = -66.216 uV 17:14:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.523 uVs 17:14:03 Integrated Voltage Measurement... 17:14:12 Voltage Offset Correction: v_off_ini = -81.663 uV, v_off_fin = -86.627 uV 17:14:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.865 uVs 17:14:12 Integrated Voltage Measurement... 17:14:21 Voltage Offset Correction: v_off_ini = -76.903 uV, v_off_fin = -68.680 uV 17:14:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.943 uVs 17:14:21 Integrated Voltage Measurement... 17:14:30 Voltage Offset Correction: v_off_ini = -73.088 uV, v_off_fin = -89.982 uV 17:14:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.420 uVs 17:14:30 Integrated Voltage Measurement... 17:14:39 Voltage Offset Correction: v_off_ini = -75.204 uV, v_off_fin = -69.455 uV 17:14:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.921 uVs 17:14:43 I1Y Average and RMS of Measurements VT = -210.195 +- 4.795 uVs I1Y = -42.039 +- 0.959 uTm 17:14:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:14:48 Integrated Voltage Measurement... 17:14:57 Voltage Offset Correction: v_off_ini = -79.735 uV, v_off_fin = -82.157 uV 17:14:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -92.473 uVs 17:14:57 Integrated Voltage Measurement... 17:15:06 Voltage Offset Correction: v_off_ini = -76.392 uV, v_off_fin = -61.747 uV 17:15:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.945 uVs 17:15:06 Integrated Voltage Measurement... 17:15:15 Voltage Offset Correction: v_off_ini = -80.355 uV, v_off_fin = -88.277 uV 17:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.777 uVs 17:15:15 Integrated Voltage Measurement... 17:15:24 Voltage Offset Correction: v_off_ini = -77.586 uV, v_off_fin = -70.492 uV 17:15:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.196 uVs 17:15:24 Integrated Voltage Measurement... 17:15:33 Voltage Offset Correction: v_off_ini = -77.069 uV, v_off_fin = -83.112 uV 17:15:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.606 uVs 17:15:33 Integrated Voltage Measurement... 17:15:42 Voltage Offset Correction: v_off_ini = -82.147 uV, v_off_fin = -75.467 uV 17:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.497 uVs 17:15:45 I2X Average and RMS of Measurements VT = -100.082 +- 3.927 uVs I2X = 9.207 +- 0.362 uTm^2 17:15:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:15:50 Integrated Voltage Measurement... 17:15:59 Voltage Offset Correction: v_off_ini = -79.115 uV, v_off_fin = -78.458 uV 17:15:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.386 uVs 17:15:59 Integrated Voltage Measurement... 17:16:08 Voltage Offset Correction: v_off_ini = -85.935 uV, v_off_fin = -84.043 uV 17:16:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.313 uVs 17:16:08 Integrated Voltage Measurement... 17:16:17 Voltage Offset Correction: v_off_ini = -84.887 uV, v_off_fin = -77.049 uV 17:16:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.188 uVs 17:16:17 Integrated Voltage Measurement... 17:16:26 Voltage Offset Correction: v_off_ini = -79.867 uV, v_off_fin = -82.954 uV 17:16:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.827 uVs 17:16:26 Integrated Voltage Measurement... 17:16:35 Voltage Offset Correction: v_off_ini = -79.448 uV, v_off_fin = -76.631 uV 17:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.260 uVs 17:16:35 Integrated Voltage Measurement... 17:16:44 Voltage Offset Correction: v_off_ini = -83.316 uV, v_off_fin = -73.762 uV 17:16:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.449 uVs 17:16:47 I2Y Average and RMS of Measurements VT = -250.404 +- 5.077 uVs I2Y = -23.037 +- 0.467 uTm^2 17:16:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:55 Integrated Voltage Measurement... 17:17:04 Voltage Offset Correction: v_off_ini = -74.793 uV, v_off_fin = -81.790 uV 17:17:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.547 uVs 17:17:04 Integrated Voltage Measurement... 17:17:13 Voltage Offset Correction: v_off_ini = -84.936 uV, v_off_fin = -91.455 uV 17:17:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.336 uVs 17:17:13 Integrated Voltage Measurement... 17:17:22 Voltage Offset Correction: v_off_ini = -100.222 uV, v_off_fin = -97.082 uV 17:17:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.350 uVs 17:17:22 Integrated Voltage Measurement... 17:17:31 Voltage Offset Correction: v_off_ini = -86.640 uV, v_off_fin = -79.965 uV 17:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.679 uVs 17:17:31 Integrated Voltage Measurement... 17:17:40 Voltage Offset Correction: v_off_ini = -72.589 uV, v_off_fin = -77.784 uV 17:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.042 uVs 17:17:40 Integrated Voltage Measurement... 17:17:49 Voltage Offset Correction: v_off_ini = -81.614 uV, v_off_fin = -66.218 uV 17:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.788 uVs 17:17:53 I1X Average and RMS of Measurements VT = -111.124 +- 3.778 uVs I1X = 22.225 +- 0.756 uTm 17:17:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:00 Integrated Voltage Measurement... 17:18:09 Voltage Offset Correction: v_off_ini = -70.183 uV, v_off_fin = -77.650 uV 17:18:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.849 uVs 17:18:09 Integrated Voltage Measurement... 17:18:18 Voltage Offset Correction: v_off_ini = -72.648 uV, v_off_fin = -52.122 uV 17:18:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.136 uVs 17:18:18 Integrated Voltage Measurement... 17:18:27 Voltage Offset Correction: v_off_ini = -64.005 uV, v_off_fin = -80.527 uV 17:18:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.144 uVs 17:18:27 Integrated Voltage Measurement... 17:18:36 Voltage Offset Correction: v_off_ini = -76.424 uV, v_off_fin = -62.429 uV 17:18:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.247 uVs 17:18:36 Integrated Voltage Measurement... 17:18:45 Voltage Offset Correction: v_off_ini = -74.487 uV, v_off_fin = -86.329 uV 17:18:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.784 uVs 17:18:45 Integrated Voltage Measurement... 17:18:54 Voltage Offset Correction: v_off_ini = -77.495 uV, v_off_fin = -71.713 uV 17:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.776 uVs 17:18:58 I1Y Average and RMS of Measurements VT = -206.989 +- 7.075 uVs I1Y = -41.398 +- 1.415 uTm 17:19:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:03 Integrated Voltage Measurement... 17:19:12 Voltage Offset Correction: v_off_ini = -83.319 uV, v_off_fin = -75.400 uV 17:19:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -101.722 uVs 17:19:13 Integrated Voltage Measurement... 17:19:22 Voltage Offset Correction: v_off_ini = -74.618 uV, v_off_fin = -66.754 uV 17:19:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.872 uVs 17:19:22 Integrated Voltage Measurement... 17:19:31 Voltage Offset Correction: v_off_ini = -71.318 uV, v_off_fin = -69.987 uV 17:19:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.569 uVs 17:19:31 Integrated Voltage Measurement... 17:19:40 Voltage Offset Correction: v_off_ini = -72.715 uV, v_off_fin = -63.043 uV 17:19:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.193 uVs 17:19:40 Integrated Voltage Measurement... 17:19:49 Voltage Offset Correction: v_off_ini = -61.366 uV, v_off_fin = -75.549 uV 17:19:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.775 uVs 17:19:49 Integrated Voltage Measurement... 17:19:58 Voltage Offset Correction: v_off_ini = -61.664 uV, v_off_fin = -64.586 uV 17:19:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.476 uVs 17:20:00 I2X Average and RMS of Measurements VT = -89.101 +- 6.156 uVs I2X = 8.197 +- 0.566 uTm^2 17:20:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:05 Integrated Voltage Measurement... 17:20:14 Voltage Offset Correction: v_off_ini = -72.333 uV, v_off_fin = -70.218 uV 17:20:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.472 uVs 17:20:14 Integrated Voltage Measurement... 17:20:23 Voltage Offset Correction: v_off_ini = -77.358 uV, v_off_fin = -76.890 uV 17:20:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.158 uVs 17:20:23 Integrated Voltage Measurement... 17:20:32 Voltage Offset Correction: v_off_ini = -84.677 uV, v_off_fin = -98.311 uV 17:20:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.245 uVs 17:20:32 Integrated Voltage Measurement... 17:20:41 Voltage Offset Correction: v_off_ini = -96.936 uV, v_off_fin = -81.139 uV 17:20:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.266 uVs 17:20:41 Integrated Voltage Measurement... 17:20:50 Voltage Offset Correction: v_off_ini = -82.687 uV, v_off_fin = -89.680 uV 17:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.581 uVs 17:20:50 Integrated Voltage Measurement... 17:20:59 Voltage Offset Correction: v_off_ini = -85.894 uV, v_off_fin = -91.812 uV 17:20:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.008 uVs 17:21:02 I2Y Average and RMS of Measurements VT = -256.788 +- 5.376 uVs I2Y = -23.625 +- 0.495 uTm^2 17:21:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:21:10 Integrated Voltage Measurement... 17:21:19 Voltage Offset Correction: v_off_ini = -82.395 uV, v_off_fin = -101.542 uV 17:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.907 uVs 17:21:19 Integrated Voltage Measurement... 17:21:28 Voltage Offset Correction: v_off_ini = -95.009 uV, v_off_fin = -94.760 uV 17:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.888 uVs 17:21:28 Integrated Voltage Measurement... 17:21:37 Voltage Offset Correction: v_off_ini = -85.063 uV, v_off_fin = -84.538 uV 17:21:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.828 uVs 17:21:37 Integrated Voltage Measurement... 17:21:46 Voltage Offset Correction: v_off_ini = -77.429 uV, v_off_fin = -65.070 uV 17:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.539 uVs 17:21:46 Integrated Voltage Measurement... 17:21:55 Voltage Offset Correction: v_off_ini = -64.386 uV, v_off_fin = -72.859 uV 17:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.158 uVs 17:21:55 Integrated Voltage Measurement... 17:22:04 Voltage Offset Correction: v_off_ini = -77.500 uV, v_off_fin = -62.034 uV 17:22:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.586 uVs 17:22:09 I1X Average and RMS of Measurements VT = -99.984 +- 11.542 uVs I1X = 19.997 +- 2.308 uTm 17:22:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:22:15 Integrated Voltage Measurement... 17:22:24 Voltage Offset Correction: v_off_ini = -71.603 uV, v_off_fin = -84.905 uV 17:22:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.492 uVs 17:22:24 Integrated Voltage Measurement... 17:22:33 Voltage Offset Correction: v_off_ini = -85.208 uV, v_off_fin = -73.343 uV 17:22:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.608 uVs 17:22:33 Integrated Voltage Measurement... 17:22:42 Voltage Offset Correction: v_off_ini = -74.386 uV, v_off_fin = -86.403 uV 17:22:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.288 uVs 17:22:42 Integrated Voltage Measurement... 17:22:51 Voltage Offset Correction: v_off_ini = -73.908 uV, v_off_fin = -74.669 uV 17:22:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.442 uVs 17:22:51 Integrated Voltage Measurement... 17:23:00 Voltage Offset Correction: v_off_ini = -81.437 uV, v_off_fin = -84.790 uV 17:23:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.419 uVs 17:23:00 Integrated Voltage Measurement... 17:23:09 Voltage Offset Correction: v_off_ini = -77.093 uV, v_off_fin = -67.922 uV 17:23:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.501 uVs 17:23:13 I1Y Average and RMS of Measurements VT = -200.792 +- 3.081 uVs I1Y = -40.157 +- 0.614 uTm 17:23:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:23:19 Integrated Voltage Measurement... 17:23:28 Voltage Offset Correction: v_off_ini = -86.266 uV, v_off_fin = -89.046 uV 17:23:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.368 uVs 17:23:28 Integrated Voltage Measurement... 17:23:37 Voltage Offset Correction: v_off_ini = -65.140 uV, v_off_fin = -77.725 uV 17:23:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.216 uVs 17:23:37 Integrated Voltage Measurement... 17:23:46 Voltage Offset Correction: v_off_ini = -78.107 uV, v_off_fin = -79.220 uV 17:23:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.798 uVs 17:23:46 Integrated Voltage Measurement... 17:23:55 Voltage Offset Correction: v_off_ini = -73.140 uV, v_off_fin = -65.893 uV 17:23:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.800 uVs 17:23:55 Integrated Voltage Measurement... 17:24:04 Voltage Offset Correction: v_off_ini = -78.455 uV, v_off_fin = -81.786 uV 17:24:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.705 uVs 17:24:04 Integrated Voltage Measurement... 17:24:13 Voltage Offset Correction: v_off_ini = -87.813 uV, v_off_fin = -66.625 uV 17:24:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.815 uVs 17:24:15 I2X Average and RMS of Measurements VT = -74.450 +- 9.144 uVs I2X = 6.849 +- 0.841 uTm^2 17:24:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:24:20 Integrated Voltage Measurement... 17:24:29 Voltage Offset Correction: v_off_ini = -65.615 uV, v_off_fin = -75.548 uV 17:24:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.524 uVs 17:24:29 Integrated Voltage Measurement... 17:24:38 Voltage Offset Correction: v_off_ini = -75.017 uV, v_off_fin = -72.098 uV 17:24:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.458 uVs 17:24:38 Integrated Voltage Measurement... 17:24:47 Voltage Offset Correction: v_off_ini = -93.820 uV, v_off_fin = -95.376 uV 17:24:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.232 uVs 17:24:47 Integrated Voltage Measurement... 17:24:56 Voltage Offset Correction: v_off_ini = -94.865 uV, v_off_fin = -107.717 uV 17:24:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.630 uVs 17:24:57 Integrated Voltage Measurement... 17:25:06 Voltage Offset Correction: v_off_ini = -92.662 uV, v_off_fin = -92.293 uV 17:25:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.723 uVs 17:25:06 Integrated Voltage Measurement... 17:25:15 Voltage Offset Correction: v_off_ini = -96.196 uV, v_off_fin = -94.502 uV 17:25:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.557 uVs 17:25:17 I2Y Average and RMS of Measurements VT = -264.854 +- 3.702 uVs I2Y = -24.367 +- 0.341 uTm^2 17:25:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:25:25 Integrated Voltage Measurement... 17:25:34 Voltage Offset Correction: v_off_ini = -91.712 uV, v_off_fin = -99.133 uV 17:25:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.392 uVs 17:25:34 Integrated Voltage Measurement... 17:25:43 Voltage Offset Correction: v_off_ini = -86.148 uV, v_off_fin = -88.088 uV 17:25:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.742 uVs 17:25:43 Integrated Voltage Measurement... 17:25:52 Voltage Offset Correction: v_off_ini = -99.367 uV, v_off_fin = -97.794 uV 17:25:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.792 uVs 17:25:52 Integrated Voltage Measurement... 17:26:01 Voltage Offset Correction: v_off_ini = -96.666 uV, v_off_fin = -87.919 uV 17:26:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.978 uVs 17:26:01 Integrated Voltage Measurement... 17:26:10 Voltage Offset Correction: v_off_ini = -93.862 uV, v_off_fin = -80.196 uV 17:26:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.793 uVs 17:26:10 Integrated Voltage Measurement... 17:26:19 Voltage Offset Correction: v_off_ini = -93.052 uV, v_off_fin = -103.883 uV 17:26:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.964 uVs 17:26:24 I1X Average and RMS of Measurements VT = -79.944 +- 5.162 uVs I1X = 15.989 +- 1.032 uTm 17:26:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:26:30 Integrated Voltage Measurement... 17:26:39 Voltage Offset Correction: v_off_ini = -114.800 uV, v_off_fin = -117.923 uV 17:26:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.195 uVs 17:26:39 Integrated Voltage Measurement... 17:26:48 Voltage Offset Correction: v_off_ini = -104.252 uV, v_off_fin = -94.455 uV 17:26:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.262 uVs 17:26:48 Integrated Voltage Measurement... 17:26:57 Voltage Offset Correction: v_off_ini = -95.412 uV, v_off_fin = -117.748 uV 17:26:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.219 uVs 17:26:57 Integrated Voltage Measurement... 17:27:06 Voltage Offset Correction: v_off_ini = -110.197 uV, v_off_fin = -113.496 uV 17:27:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.944 uVs 17:27:06 Integrated Voltage Measurement... 17:27:15 Voltage Offset Correction: v_off_ini = -120.663 uV, v_off_fin = -123.192 uV 17:27:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.041 uVs 17:27:15 Integrated Voltage Measurement... 17:27:24 Voltage Offset Correction: v_off_ini = -112.292 uV, v_off_fin = -106.734 uV 17:27:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.708 uVs 17:27:29 I1Y Average and RMS of Measurements VT = -207.061 +- 3.991 uVs I1Y = -41.411 +- 0.797 uTm 17:27:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:27:34 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = -101.896 uV, v_off_fin = -105.140 uV 17:27:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.652 uVs 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = -108.210 uV, v_off_fin = -93.412 uV 17:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.919 uVs 17:27:52 Integrated Voltage Measurement... 17:28:01 Voltage Offset Correction: v_off_ini = -110.662 uV, v_off_fin = -120.049 uV 17:28:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.075 uVs 17:28:01 Integrated Voltage Measurement... 17:28:10 Voltage Offset Correction: v_off_ini = -110.928 uV, v_off_fin = -92.052 uV 17:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.890 uVs 17:28:10 Integrated Voltage Measurement... 17:28:19 Voltage Offset Correction: v_off_ini = -110.904 uV, v_off_fin = -114.531 uV 17:28:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.144 uVs 17:28:19 Integrated Voltage Measurement... 17:28:28 Voltage Offset Correction: v_off_ini = -115.467 uV, v_off_fin = -103.265 uV 17:28:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.384 uVs 17:28:30 I2X Average and RMS of Measurements VT = -58.177 +- 1.343 uVs I2X = 5.352 +- 0.124 uTm^2 17:28:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:28:36 Integrated Voltage Measurement... 17:28:45 Voltage Offset Correction: v_off_ini = -104.639 uV, v_off_fin = -94.593 uV 17:28:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.294 uVs 17:28:45 Integrated Voltage Measurement... 17:28:54 Voltage Offset Correction: v_off_ini = -70.135 uV, v_off_fin = -78.259 uV 17:28:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.094 uVs 17:28:54 Integrated Voltage Measurement... 17:29:03 Voltage Offset Correction: v_off_ini = -92.036 uV, v_off_fin = -102.169 uV 17:29:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.705 uVs 17:29:03 Integrated Voltage Measurement... 17:29:12 Voltage Offset Correction: v_off_ini = -101.422 uV, v_off_fin = -112.802 uV 17:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.651 uVs 17:29:12 Integrated Voltage Measurement... 17:29:21 Voltage Offset Correction: v_off_ini = -107.110 uV, v_off_fin = -112.497 uV 17:29:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.742 uVs 17:29:21 Integrated Voltage Measurement... 17:29:30 Voltage Offset Correction: v_off_ini = -99.434 uV, v_off_fin = -112.753 uV 17:29:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.142 uVs 17:29:32 I2Y Average and RMS of Measurements VT = -251.771 +- 6.526 uVs I2Y = -23.163 +- 0.600 uTm^2 17:29:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:29:53 Integrated Voltage Measurement... 17:30:02 Voltage Offset Correction: v_off_ini = -59.268 uV, v_off_fin = -79.173 uV 17:30:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.379 uVs 17:30:02 Integrated Voltage Measurement... 17:30:11 Voltage Offset Correction: v_off_ini = -63.115 uV, v_off_fin = -85.251 uV 17:30:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.363 uVs 17:30:11 Integrated Voltage Measurement... 17:30:20 Voltage Offset Correction: v_off_ini = -90.318 uV, v_off_fin = -93.046 uV 17:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.606 uVs 17:30:20 Integrated Voltage Measurement... 17:30:29 Voltage Offset Correction: v_off_ini = -77.998 uV, v_off_fin = -82.116 uV 17:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.249 uVs 17:30:30 Integrated Voltage Measurement... 17:30:38 Voltage Offset Correction: v_off_ini = -96.160 uV, v_off_fin = -90.599 uV 17:30:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.439 uVs 17:30:39 Integrated Voltage Measurement... 17:30:47 Voltage Offset Correction: v_off_ini = -84.336 uV, v_off_fin = -92.381 uV 17:30:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.423 uVs 17:30:52 I1X Average and RMS of Measurements VT = -121.076 +- 3.177 uVs I1X = 24.216 +- 0.635 uTm 17:30:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:30:59 Integrated Voltage Measurement... 17:31:07 Voltage Offset Correction: v_off_ini = -83.109 uV, v_off_fin = -87.519 uV 17:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.096 uVs 17:31:08 Integrated Voltage Measurement... 17:31:16 Voltage Offset Correction: v_off_ini = -76.379 uV, v_off_fin = -70.529 uV 17:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.157 uVs 17:31:17 Integrated Voltage Measurement... 17:31:25 Voltage Offset Correction: v_off_ini = -81.205 uV, v_off_fin = -84.175 uV 17:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.850 uVs 17:31:26 Integrated Voltage Measurement... 17:31:34 Voltage Offset Correction: v_off_ini = -82.210 uV, v_off_fin = -67.781 uV 17:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.162 uVs 17:31:35 Integrated Voltage Measurement... 17:31:43 Voltage Offset Correction: v_off_ini = -75.137 uV, v_off_fin = -82.317 uV 17:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.322 uVs 17:31:44 Integrated Voltage Measurement... 17:31:52 Voltage Offset Correction: v_off_ini = -78.919 uV, v_off_fin = -68.365 uV 17:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.090 uVs 17:31:57 I1Y Average and RMS of Measurements VT = -165.779 +- 4.514 uVs I1Y = -33.156 +- 0.903 uTm 17:32:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:32:04 Integrated Voltage Measurement... 17:32:13 Voltage Offset Correction: v_off_ini = -67.008 uV, v_off_fin = -64.386 uV 17:32:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.532 uVs 17:32:14 Integrated Voltage Measurement... 17:32:23 Voltage Offset Correction: v_off_ini = -56.937 uV, v_off_fin = -44.253 uV 17:32:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.653 uVs 17:32:23 Integrated Voltage Measurement... 17:32:32 Voltage Offset Correction: v_off_ini = -61.593 uV, v_off_fin = -83.729 uV 17:32:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.877 uVs 17:32:32 Integrated Voltage Measurement... 17:32:41 Voltage Offset Correction: v_off_ini = -61.349 uV, v_off_fin = -54.038 uV 17:32:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.542 uVs 17:32:41 Integrated Voltage Measurement... 17:32:50 Voltage Offset Correction: v_off_ini = -80.998 uV, v_off_fin = -66.469 uV 17:32:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.639 uVs 17:32:50 Integrated Voltage Measurement... 17:32:59 Voltage Offset Correction: v_off_ini = -70.256 uV, v_off_fin = -56.054 uV 17:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.303 uVs 17:33:01 I2X Average and RMS of Measurements VT = -98.091 +- 1.731 uVs I2X = 9.025 +- 0.159 uTm^2 17:33:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:33:09 Integrated Voltage Measurement... 17:33:18 Voltage Offset Correction: v_off_ini = -70.113 uV, v_off_fin = -65.447 uV 17:33:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.878 uVs 17:33:18 Integrated Voltage Measurement... 17:33:27 Voltage Offset Correction: v_off_ini = -67.133 uV, v_off_fin = -66.363 uV 17:33:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.415 uVs 17:33:27 Integrated Voltage Measurement... 17:33:36 Voltage Offset Correction: v_off_ini = -85.969 uV, v_off_fin = -81.263 uV 17:33:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.059 uVs 17:33:36 Integrated Voltage Measurement... 17:33:45 Voltage Offset Correction: v_off_ini = -72.558 uV, v_off_fin = -56.148 uV 17:33:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.853 uVs 17:33:45 Integrated Voltage Measurement... 17:33:54 Voltage Offset Correction: v_off_ini = -57.283 uV, v_off_fin = -63.368 uV 17:33:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.068 uVs 17:33:54 Integrated Voltage Measurement... 17:34:03 Voltage Offset Correction: v_off_ini = -60.923 uV, v_off_fin = -44.409 uV 17:34:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.743 uVs 17:34:06 I2Y Average and RMS of Measurements VT = -212.003 +- 9.317 uVs I2Y = -19.504 +- 0.857 uTm^2 17:34:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:34:14 Integrated Voltage Measurement... 17:34:23 Voltage Offset Correction: v_off_ini = -72.404 uV, v_off_fin = -61.479 uV 17:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -124.044 uVs 17:34:23 Integrated Voltage Measurement... 17:34:32 Voltage Offset Correction: v_off_ini = -65.856 uV, v_off_fin = -64.383 uV 17:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.198 uVs 17:34:33 Integrated Voltage Measurement... 17:34:41 Voltage Offset Correction: v_off_ini = -64.311 uV, v_off_fin = -63.856 uV 17:34:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.257 uVs 17:34:42 Integrated Voltage Measurement... 17:34:50 Voltage Offset Correction: v_off_ini = -52.679 uV, v_off_fin = -52.847 uV 17:34:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.700 uVs 17:34:51 Integrated Voltage Measurement... 17:35:00 Voltage Offset Correction: v_off_ini = -46.019 uV, v_off_fin = -50.900 uV 17:35:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.092 uVs 17:35:00 Integrated Voltage Measurement... 17:35:09 Voltage Offset Correction: v_off_ini = -37.501 uV, v_off_fin = -45.976 uV 17:35:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.109 uVs 17:35:13 I1X Average and RMS of Measurements VT = -118.400 +- 5.335 uVs I1X = 23.681 +- 1.067 uTm 17:35:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:35:20 Integrated Voltage Measurement... 17:35:29 Voltage Offset Correction: v_off_ini = -51.914 uV, v_off_fin = -67.304 uV 17:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.833 uVs 17:35:29 Integrated Voltage Measurement... 17:35:38 Voltage Offset Correction: v_off_ini = -55.700 uV, v_off_fin = -41.286 uV 17:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.236 uVs 17:35:38 Integrated Voltage Measurement... 17:35:47 Voltage Offset Correction: v_off_ini = -56.907 uV, v_off_fin = -65.714 uV 17:35:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.685 uVs 17:35:47 Integrated Voltage Measurement... 17:35:56 Voltage Offset Correction: v_off_ini = -67.151 uV, v_off_fin = -52.863 uV 17:35:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.951 uVs 17:35:56 Integrated Voltage Measurement... 17:36:05 Voltage Offset Correction: v_off_ini = -63.941 uV, v_off_fin = -73.412 uV 17:36:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.737 uVs 17:36:05 Integrated Voltage Measurement... 17:36:14 Voltage Offset Correction: v_off_ini = -71.199 uV, v_off_fin = -57.333 uV 17:36:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.493 uVs 17:36:18 I1Y Average and RMS of Measurements VT = -192.822 +- 7.976 uVs I1Y = -38.564 +- 1.595 uTm 17:36:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:36:25 Integrated Voltage Measurement... 17:36:34 Voltage Offset Correction: v_off_ini = -60.219 uV, v_off_fin = -81.079 uV 17:36:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.142 uVs 17:36:35 Integrated Voltage Measurement... 17:36:44 Voltage Offset Correction: v_off_ini = -66.444 uV, v_off_fin = -60.600 uV 17:36:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.526 uVs 17:36:44 Integrated Voltage Measurement... 17:36:53 Voltage Offset Correction: v_off_ini = -80.979 uV, v_off_fin = -81.802 uV 17:36:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.040 uVs 17:36:53 Integrated Voltage Measurement... 17:37:02 Voltage Offset Correction: v_off_ini = -69.490 uV, v_off_fin = -73.747 uV 17:37:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.686 uVs 17:37:02 Integrated Voltage Measurement... 17:37:11 Voltage Offset Correction: v_off_ini = -77.588 uV, v_off_fin = -85.559 uV 17:37:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.309 uVs 17:37:11 Integrated Voltage Measurement... 17:37:20 Voltage Offset Correction: v_off_ini = -75.888 uV, v_off_fin = -62.450 uV 17:37:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.259 uVs 17:37:22 I2X Average and RMS of Measurements VT = -103.160 +- 8.380 uVs I2X = 9.491 +- 0.771 uTm^2 17:37:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:37:30 Integrated Voltage Measurement... 17:37:39 Voltage Offset Correction: v_off_ini = -72.618 uV, v_off_fin = -75.390 uV 17:37:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.789 uVs 17:37:39 Integrated Voltage Measurement... 17:37:48 Voltage Offset Correction: v_off_ini = -73.346 uV, v_off_fin = -75.218 uV 17:37:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.689 uVs 17:37:48 Integrated Voltage Measurement... 17:37:57 Voltage Offset Correction: v_off_ini = -68.007 uV, v_off_fin = -63.493 uV 17:37:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.068 uVs 17:37:57 Integrated Voltage Measurement... 17:38:06 Voltage Offset Correction: v_off_ini = -63.530 uV, v_off_fin = -64.431 uV 17:38:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.904 uVs 17:38:06 Integrated Voltage Measurement... 17:38:15 Voltage Offset Correction: v_off_ini = -62.369 uV, v_off_fin = -64.133 uV 17:38:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.736 uVs 17:38:15 Integrated Voltage Measurement... 17:38:24 Voltage Offset Correction: v_off_ini = -65.504 uV, v_off_fin = -61.767 uV 17:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.949 uVs 17:38:26 I2Y Average and RMS of Measurements VT = -232.856 +- 2.407 uVs I2Y = -21.423 +- 0.221 uTm^2 17:38:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:35 Integrated Voltage Measurement... 17:38:44 Voltage Offset Correction: v_off_ini = -55.867 uV, v_off_fin = -69.503 uV 17:38:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.892 uVs 17:38:44 Integrated Voltage Measurement... 17:38:53 Voltage Offset Correction: v_off_ini = -63.671 uV, v_off_fin = -54.330 uV 17:38:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.230 uVs 17:38:53 Integrated Voltage Measurement... 17:39:02 Voltage Offset Correction: v_off_ini = -54.851 uV, v_off_fin = -47.979 uV 17:39:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.190 uVs 17:39:02 Integrated Voltage Measurement... 17:39:11 Voltage Offset Correction: v_off_ini = -57.768 uV, v_off_fin = -45.631 uV 17:39:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.154 uVs 17:39:11 Integrated Voltage Measurement... 17:39:20 Voltage Offset Correction: v_off_ini = -54.721 uV, v_off_fin = -58.693 uV 17:39:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.513 uVs 17:39:20 Integrated Voltage Measurement... 17:39:29 Voltage Offset Correction: v_off_ini = -55.433 uV, v_off_fin = -47.985 uV 17:39:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.972 uVs 17:39:34 I1X Average and RMS of Measurements VT = -128.492 +- 8.122 uVs I1X = 25.699 +- 1.624 uTm 17:39:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:39:40 Integrated Voltage Measurement... 17:39:49 Voltage Offset Correction: v_off_ini = -47.076 uV, v_off_fin = -60.555 uV 17:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.106 uVs 17:39:49 Integrated Voltage Measurement... 17:39:58 Voltage Offset Correction: v_off_ini = -40.337 uV, v_off_fin = -30.478 uV 17:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.128 uVs 17:39:58 Integrated Voltage Measurement... 17:40:07 Voltage Offset Correction: v_off_ini = -61.139 uV, v_off_fin = -59.919 uV 17:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.668 uVs 17:40:07 Integrated Voltage Measurement... 17:40:16 Voltage Offset Correction: v_off_ini = -53.151 uV, v_off_fin = -40.107 uV 17:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.413 uVs 17:40:16 Integrated Voltage Measurement... 17:40:25 Voltage Offset Correction: v_off_ini = -55.740 uV, v_off_fin = -68.665 uV 17:40:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.123 uVs 17:40:25 Integrated Voltage Measurement... 17:40:34 Voltage Offset Correction: v_off_ini = -49.013 uV, v_off_fin = -49.676 uV 17:40:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.122 uVs 17:40:38 I1Y Average and RMS of Measurements VT = -202.927 +- 10.708 uVs I1Y = -40.585 +- 2.142 uTm 17:40:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:40:46 Integrated Voltage Measurement... 17:40:55 Voltage Offset Correction: v_off_ini = -54.775 uV, v_off_fin = -61.079 uV 17:40:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -105.884 uVs 17:40:55 Integrated Voltage Measurement... 17:41:04 Voltage Offset Correction: v_off_ini = -43.025 uV, v_off_fin = -34.147 uV 17:41:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.251 uVs 17:41:04 Integrated Voltage Measurement... 17:41:13 Voltage Offset Correction: v_off_ini = -48.474 uV, v_off_fin = -52.787 uV 17:41:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.010 uVs 17:41:13 Integrated Voltage Measurement... 17:41:22 Voltage Offset Correction: v_off_ini = -49.510 uV, v_off_fin = -44.627 uV 17:41:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.158 uVs 17:41:22 Integrated Voltage Measurement... 17:41:31 Voltage Offset Correction: v_off_ini = -58.508 uV, v_off_fin = -62.952 uV 17:41:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.807 uVs 17:41:31 Integrated Voltage Measurement... 17:41:40 Voltage Offset Correction: v_off_ini = -58.574 uV, v_off_fin = -40.443 uV 17:41:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.782 uVs 17:41:43 I2X Average and RMS of Measurements VT = -108.315 +- 5.416 uVs I2X = 9.965 +- 0.498 uTm^2 17:41:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:41:50 Integrated Voltage Measurement... 17:41:59 Voltage Offset Correction: v_off_ini = -49.134 uV, v_off_fin = -52.654 uV 17:41:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.748 uVs 17:41:59 Integrated Voltage Measurement... 17:42:08 Voltage Offset Correction: v_off_ini = -45.069 uV, v_off_fin = -45.054 uV 17:42:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.547 uVs 17:42:08 Integrated Voltage Measurement... 17:42:17 Voltage Offset Correction: v_off_ini = -49.404 uV, v_off_fin = -51.089 uV 17:42:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.571 uVs 17:42:18 Integrated Voltage Measurement... 17:42:26 Voltage Offset Correction: v_off_ini = -52.248 uV, v_off_fin = -55.107 uV 17:42:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.925 uVs 17:42:27 Integrated Voltage Measurement... 17:42:36 Voltage Offset Correction: v_off_ini = -55.155 uV, v_off_fin = -52.673 uV 17:42:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.785 uVs 17:42:36 Integrated Voltage Measurement... 17:42:45 Voltage Offset Correction: v_off_ini = -59.822 uV, v_off_fin = -45.283 uV 17:42:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.908 uVs 17:42:47 I2Y Average and RMS of Measurements VT = -253.581 +- 5.741 uVs I2Y = -23.329 +- 0.528 uTm^2 17:42:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:42:56 Integrated Voltage Measurement... 17:43:05 Voltage Offset Correction: v_off_ini = -49.922 uV, v_off_fin = -56.512 uV 17:43:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.530 uVs 17:43:05 Integrated Voltage Measurement... 17:43:14 Voltage Offset Correction: v_off_ini = -46.370 uV, v_off_fin = -43.681 uV 17:43:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.539 uVs 17:43:14 Integrated Voltage Measurement... 17:43:23 Voltage Offset Correction: v_off_ini = -38.758 uV, v_off_fin = -53.470 uV 17:43:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.349 uVs 17:43:23 Integrated Voltage Measurement... 17:43:32 Voltage Offset Correction: v_off_ini = -71.581 uV, v_off_fin = -57.467 uV 17:43:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.257 uVs 17:43:32 Integrated Voltage Measurement... 17:43:41 Voltage Offset Correction: v_off_ini = -60.702 uV, v_off_fin = -67.581 uV 17:43:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.141 uVs 17:43:41 Integrated Voltage Measurement... 17:43:50 Voltage Offset Correction: v_off_ini = -54.781 uV, v_off_fin = -51.034 uV 17:43:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.225 uVs 17:43:54 I1X Average and RMS of Measurements VT = -117.674 +- 2.240 uVs I1X = 23.535 +- 0.448 uTm 17:43:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:44:01 Integrated Voltage Measurement... 17:44:10 Voltage Offset Correction: v_off_ini = -63.938 uV, v_off_fin = -72.391 uV 17:44:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.379 uVs 17:44:10 Integrated Voltage Measurement... 17:44:19 Voltage Offset Correction: v_off_ini = -72.993 uV, v_off_fin = -53.612 uV 17:44:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.279 uVs 17:44:19 Integrated Voltage Measurement... 17:44:28 Voltage Offset Correction: v_off_ini = -67.955 uV, v_off_fin = -67.683 uV 17:44:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.187 uVs 17:44:28 Integrated Voltage Measurement... 17:44:37 Voltage Offset Correction: v_off_ini = -71.988 uV, v_off_fin = -52.274 uV 17:44:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.261 uVs 17:44:37 Integrated Voltage Measurement... 17:44:46 Voltage Offset Correction: v_off_ini = -58.671 uV, v_off_fin = -73.469 uV 17:44:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.959 uVs 17:44:46 Integrated Voltage Measurement... 17:44:55 Voltage Offset Correction: v_off_ini = -60.361 uV, v_off_fin = -52.996 uV 17:44:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.396 uVs 17:44:59 I1Y Average and RMS of Measurements VT = -235.744 +- 2.737 uVs I1Y = -47.149 +- 0.548 uTm 17:45:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:45:07 Integrated Voltage Measurement... 17:45:16 Voltage Offset Correction: v_off_ini = -59.406 uV, v_off_fin = -68.069 uV 17:45:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -107.165 uVs 17:45:16 Integrated Voltage Measurement... 17:45:25 Voltage Offset Correction: v_off_ini = -55.394 uV, v_off_fin = -30.781 uV 17:45:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.964 uVs 17:45:25 Integrated Voltage Measurement... 17:45:34 Voltage Offset Correction: v_off_ini = -41.580 uV, v_off_fin = -56.095 uV 17:45:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.089 uVs 17:45:34 Integrated Voltage Measurement... 17:45:43 Voltage Offset Correction: v_off_ini = -46.067 uV, v_off_fin = -42.855 uV 17:45:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.094 uVs 17:45:43 Integrated Voltage Measurement... 17:45:52 Voltage Offset Correction: v_off_ini = -45.169 uV, v_off_fin = -53.625 uV 17:45:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.166 uVs 17:45:52 Integrated Voltage Measurement... 17:46:01 Voltage Offset Correction: v_off_ini = -57.375 uV, v_off_fin = -42.312 uV 17:46:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.249 uVs 17:46:03 I2X Average and RMS of Measurements VT = -109.955 +- 4.505 uVs I2X = 10.116 +- 0.415 uTm^2 17:46:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:46:11 Integrated Voltage Measurement... 17:46:20 Voltage Offset Correction: v_off_ini = -52.280 uV, v_off_fin = -48.562 uV 17:46:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.433 uVs 17:46:20 Integrated Voltage Measurement... 17:46:29 Voltage Offset Correction: v_off_ini = -41.191 uV, v_off_fin = -39.715 uV 17:46:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.753 uVs 17:46:29 Integrated Voltage Measurement... 17:46:38 Voltage Offset Correction: v_off_ini = -38.191 uV, v_off_fin = -41.176 uV 17:46:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.777 uVs 17:46:38 Integrated Voltage Measurement... 17:46:47 Voltage Offset Correction: v_off_ini = -48.476 uV, v_off_fin = -40.264 uV 17:46:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.190 uVs 17:46:47 Integrated Voltage Measurement... 17:46:56 Voltage Offset Correction: v_off_ini = -39.406 uV, v_off_fin = -27.477 uV 17:46:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.515 uVs 17:46:56 Integrated Voltage Measurement... 17:47:05 Voltage Offset Correction: v_off_ini = -33.954 uV, v_off_fin = -55.922 uV 17:47:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.959 uVs 17:47:07 I2Y Average and RMS of Measurements VT = -280.771 +- 5.838 uVs I2Y = -25.831 +- 0.537 uTm^2 17:47:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:47:16 Integrated Voltage Measurement... 17:47:25 Voltage Offset Correction: v_off_ini = -54.711 uV, v_off_fin = -66.264 uV 17:47:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.167 uVs 17:47:25 Integrated Voltage Measurement... 17:47:34 Voltage Offset Correction: v_off_ini = -60.703 uV, v_off_fin = -51.551 uV 17:47:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.403 uVs 17:47:34 Integrated Voltage Measurement... 17:47:43 Voltage Offset Correction: v_off_ini = -66.803 uV, v_off_fin = -61.903 uV 17:47:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.493 uVs 17:47:43 Integrated Voltage Measurement... 17:47:52 Voltage Offset Correction: v_off_ini = -70.725 uV, v_off_fin = -68.871 uV 17:47:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.436 uVs 17:47:52 Integrated Voltage Measurement... 17:48:01 Voltage Offset Correction: v_off_ini = -72.281 uV, v_off_fin = -73.706 uV 17:48:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.158 uVs 17:48:01 Integrated Voltage Measurement... 17:48:10 Voltage Offset Correction: v_off_ini = -81.260 uV, v_off_fin = -69.413 uV 17:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.415 uVs 17:48:14 I1X Average and RMS of Measurements VT = -132.345 +- 9.632 uVs I1X = 26.469 +- 1.926 uTm 17:48:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:48:21 Integrated Voltage Measurement... 17:48:30 Voltage Offset Correction: v_off_ini = -71.531 uV, v_off_fin = -76.977 uV 17:48:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.200 uVs 17:48:30 Integrated Voltage Measurement... 17:48:39 Voltage Offset Correction: v_off_ini = -74.713 uV, v_off_fin = -70.518 uV 17:48:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.954 uVs 17:48:39 Integrated Voltage Measurement... 17:48:48 Voltage Offset Correction: v_off_ini = -76.706 uV, v_off_fin = -75.242 uV 17:48:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.364 uVs 17:48:48 Integrated Voltage Measurement... 17:48:57 Voltage Offset Correction: v_off_ini = -60.593 uV, v_off_fin = -53.152 uV 17:48:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.014 uVs 17:48:57 Integrated Voltage Measurement... 17:49:06 Voltage Offset Correction: v_off_ini = -47.879 uV, v_off_fin = -66.906 uV 17:49:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -247.022 uVs 17:49:06 Integrated Voltage Measurement... 17:49:15 Voltage Offset Correction: v_off_ini = -66.988 uV, v_off_fin = -44.367 uV 17:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.448 uVs 17:49:19 I1Y Average and RMS of Measurements VT = -244.167 +- 8.549 uVs I1Y = -48.834 +- 1.710 uTm 17:49:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:49:27 Integrated Voltage Measurement... 17:49:36 Voltage Offset Correction: v_off_ini = -69.280 uV, v_off_fin = -76.544 uV 17:49:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -109.965 uVs 17:49:36 Integrated Voltage Measurement... 17:49:45 Voltage Offset Correction: v_off_ini = -72.675 uV, v_off_fin = -61.843 uV 17:49:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.471 uVs 17:49:45 Integrated Voltage Measurement... 17:49:54 Voltage Offset Correction: v_off_ini = -74.713 uV, v_off_fin = -70.225 uV 17:49:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.400 uVs 17:49:54 Integrated Voltage Measurement... 17:50:03 Voltage Offset Correction: v_off_ini = -70.356 uV, v_off_fin = -54.698 uV 17:50:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.111 uVs 17:50:03 Integrated Voltage Measurement... 17:50:12 Voltage Offset Correction: v_off_ini = -69.999 uV, v_off_fin = -87.253 uV 17:50:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.844 uVs 17:50:12 Integrated Voltage Measurement... 17:50:21 Voltage Offset Correction: v_off_ini = -65.226 uV, v_off_fin = -76.787 uV 17:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.204 uVs 17:50:24 I2X Average and RMS of Measurements VT = -116.666 +- 4.820 uVs I2X = 10.733 +- 0.444 uTm^2 17:50:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:50:31 Integrated Voltage Measurement... 17:50:40 Voltage Offset Correction: v_off_ini = -75.650 uV, v_off_fin = -77.168 uV 17:50:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.157 uVs 17:50:40 Integrated Voltage Measurement... 17:50:49 Voltage Offset Correction: v_off_ini = -75.119 uV, v_off_fin = -69.427 uV 17:50:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.715 uVs 17:50:49 Integrated Voltage Measurement... 17:50:58 Voltage Offset Correction: v_off_ini = -70.398 uV, v_off_fin = -80.998 uV 17:50:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.860 uVs 17:50:58 Integrated Voltage Measurement... 17:51:07 Voltage Offset Correction: v_off_ini = -76.885 uV, v_off_fin = -74.939 uV 17:51:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.378 uVs 17:51:08 Integrated Voltage Measurement... 17:51:16 Voltage Offset Correction: v_off_ini = -73.462 uV, v_off_fin = -76.486 uV 17:51:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.510 uVs 17:51:17 Integrated Voltage Measurement... 17:51:26 Voltage Offset Correction: v_off_ini = -80.557 uV, v_off_fin = -80.337 uV 17:51:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.338 uVs 17:51:28 I2Y Average and RMS of Measurements VT = -293.160 +- 3.570 uVs I2Y = -26.971 +- 0.328 uTm^2 17:51:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:51:40 Integrated Voltage Measurement... 17:51:49 Voltage Offset Correction: v_off_ini = -83.265 uV, v_off_fin = -97.489 uV 17:51:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -130.960 uVs 17:51:49 Integrated Voltage Measurement... 17:51:58 Voltage Offset Correction: v_off_ini = -84.585 uV, v_off_fin = -84.906 uV 17:51:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.452 uVs 17:51:58 Integrated Voltage Measurement... 17:52:07 Voltage Offset Correction: v_off_ini = -96.025 uV, v_off_fin = -86.971 uV 17:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.532 uVs 17:52:07 Integrated Voltage Measurement... 17:52:16 Voltage Offset Correction: v_off_ini = -85.682 uV, v_off_fin = -84.280 uV 17:52:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 161.144 uVs 17:52:16 Integrated Voltage Measurement... 17:52:25 Voltage Offset Correction: v_off_ini = -81.918 uV, v_off_fin = -91.608 uV 17:52:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.054 uVs 17:52:25 Integrated Voltage Measurement... 17:52:34 Voltage Offset Correction: v_off_ini = -102.148 uV, v_off_fin = -89.906 uV 17:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.042 uVs 17:52:38 I1X Average and RMS of Measurements VT = -135.864 +- 9.885 uVs I1X = 27.175 +- 1.978 uTm 17:52:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:52:45 Integrated Voltage Measurement... 17:52:54 Voltage Offset Correction: v_off_ini = -91.606 uV, v_off_fin = -102.691 uV 17:52:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.300 uVs 17:52:54 Integrated Voltage Measurement... 17:53:03 Voltage Offset Correction: v_off_ini = -91.893 uV, v_off_fin = -89.550 uV 17:53:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.056 uVs 17:53:03 Integrated Voltage Measurement... 17:53:12 Voltage Offset Correction: v_off_ini = -101.258 uV, v_off_fin = -94.249 uV 17:53:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.064 uVs 17:53:12 Integrated Voltage Measurement... 17:53:21 Voltage Offset Correction: v_off_ini = -86.070 uV, v_off_fin = -91.869 uV 17:53:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.847 uVs 17:53:21 Integrated Voltage Measurement... 17:53:30 Voltage Offset Correction: v_off_ini = -109.359 uV, v_off_fin = -117.938 uV 17:53:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.502 uVs 17:53:30 Integrated Voltage Measurement... 17:53:39 Voltage Offset Correction: v_off_ini = -113.426 uV, v_off_fin = -95.949 uV 17:53:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.731 uVs 17:53:43 I1Y Average and RMS of Measurements VT = -210.084 +- 6.427 uVs I1Y = -42.017 +- 1.285 uTm 17:53:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:53:48 Integrated Voltage Measurement... 17:53:57 Voltage Offset Correction: v_off_ini = -108.539 uV, v_off_fin = -116.340 uV 17:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.715 uVs 17:53:57 Integrated Voltage Measurement... 17:54:06 Voltage Offset Correction: v_off_ini = -107.845 uV, v_off_fin = -103.673 uV 17:54:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.679 uVs 17:54:06 Integrated Voltage Measurement... 17:54:15 Voltage Offset Correction: v_off_ini = -95.955 uV, v_off_fin = -92.843 uV 17:54:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.798 uVs 17:54:15 Integrated Voltage Measurement... 17:54:24 Voltage Offset Correction: v_off_ini = -93.705 uV, v_off_fin = -96.576 uV 17:54:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.763 uVs 17:54:25 Integrated Voltage Measurement... 17:54:34 Voltage Offset Correction: v_off_ini = -101.301 uV, v_off_fin = -111.112 uV 17:54:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.838 uVs 17:54:34 Integrated Voltage Measurement... 17:54:43 Voltage Offset Correction: v_off_ini = -98.374 uV, v_off_fin = -94.059 uV 17:54:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 113.919 uVs 17:54:45 I2X Average and RMS of Measurements VT = -117.785 +- 5.543 uVs I2X = 10.836 +- 0.510 uTm^2 17:54:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:54:50 Integrated Voltage Measurement... 17:54:59 Voltage Offset Correction: v_off_ini = -100.849 uV, v_off_fin = -108.720 uV 17:54:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.402 uVs 17:54:59 Integrated Voltage Measurement... 17:55:08 Voltage Offset Correction: v_off_ini = -110.396 uV, v_off_fin = -116.291 uV 17:55:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 245.638 uVs 17:55:08 Integrated Voltage Measurement... 17:55:17 Voltage Offset Correction: v_off_ini = -115.352 uV, v_off_fin = -108.943 uV 17:55:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.327 uVs 17:55:17 Integrated Voltage Measurement... 17:55:26 Voltage Offset Correction: v_off_ini = -109.543 uV, v_off_fin = -104.117 uV 17:55:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.629 uVs 17:55:26 Integrated Voltage Measurement... 17:55:35 Voltage Offset Correction: v_off_ini = -106.140 uV, v_off_fin = -96.640 uV 17:55:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.365 uVs 17:55:35 Integrated Voltage Measurement... 17:55:44 Voltage Offset Correction: v_off_ini = -92.307 uV, v_off_fin = -98.701 uV 17:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.293 uVs 17:55:47 I2Y Average and RMS of Measurements VT = -246.776 +- 4.247 uVs I2Y = -22.704 +- 0.391 uTm^2 17:55:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:55:55 Integrated Voltage Measurement... 17:56:04 Voltage Offset Correction: v_off_ini = -87.931 uV, v_off_fin = -97.465 uV 17:56:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.016 uVs 17:56:04 Integrated Voltage Measurement... 17:56:13 Voltage Offset Correction: v_off_ini = -91.521 uV, v_off_fin = -97.315 uV 17:56:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.203 uVs 17:56:13 Integrated Voltage Measurement... 17:56:22 Voltage Offset Correction: v_off_ini = -88.978 uV, v_off_fin = -104.485 uV 17:56:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.320 uVs 17:56:22 Integrated Voltage Measurement... 17:56:31 Voltage Offset Correction: v_off_ini = -82.632 uV, v_off_fin = -78.722 uV 17:56:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.651 uVs 17:56:31 Integrated Voltage Measurement... 17:56:40 Voltage Offset Correction: v_off_ini = -91.162 uV, v_off_fin = -90.923 uV 17:56:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.509 uVs 17:56:40 Integrated Voltage Measurement... 17:56:49 Voltage Offset Correction: v_off_ini = -88.324 uV, v_off_fin = -85.507 uV 17:56:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.077 uVs 17:56:53 I1X Average and RMS of Measurements VT = -126.796 +- 5.643 uVs I1X = 25.360 +- 1.128 uTm 17:56:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:57:00 Integrated Voltage Measurement... 17:57:09 Voltage Offset Correction: v_off_ini = -90.444 uV, v_off_fin = -93.304 uV 17:57:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.988 uVs 17:57:09 Integrated Voltage Measurement... 17:57:18 Voltage Offset Correction: v_off_ini = -79.339 uV, v_off_fin = -89.447 uV 17:57:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.771 uVs 17:57:18 Integrated Voltage Measurement... 17:57:27 Voltage Offset Correction: v_off_ini = -92.570 uV, v_off_fin = -102.378 uV 17:57:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.755 uVs 17:57:27 Integrated Voltage Measurement... 17:57:36 Voltage Offset Correction: v_off_ini = -92.212 uV, v_off_fin = -79.388 uV 17:57:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.319 uVs 17:57:36 Integrated Voltage Measurement... 17:57:45 Voltage Offset Correction: v_off_ini = -89.156 uV, v_off_fin = -89.684 uV 17:57:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.465 uVs 17:57:45 Integrated Voltage Measurement... 17:57:54 Voltage Offset Correction: v_off_ini = -89.373 uV, v_off_fin = -83.705 uV 17:57:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.124 uVs 17:57:58 I1Y Average and RMS of Measurements VT = -206.404 +- 4.080 uVs I1Y = -41.281 +- 0.816 uTm 17:58:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:58:04 Integrated Voltage Measurement... 17:58:12 Voltage Offset Correction: v_off_ini = -92.326 uV, v_off_fin = -99.224 uV 17:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.350 uVs 17:58:13 Integrated Voltage Measurement... 17:58:22 Voltage Offset Correction: v_off_ini = -88.930 uV, v_off_fin = -88.098 uV 17:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.956 uVs 17:58:22 Integrated Voltage Measurement... 17:58:31 Voltage Offset Correction: v_off_ini = -107.947 uV, v_off_fin = -115.976 uV 17:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.889 uVs 17:58:31 Integrated Voltage Measurement... 17:58:40 Voltage Offset Correction: v_off_ini = -109.440 uV, v_off_fin = -108.322 uV 17:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.623 uVs 17:58:40 Integrated Voltage Measurement... 17:58:49 Voltage Offset Correction: v_off_ini = -125.282 uV, v_off_fin = -130.222 uV 17:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.133 uVs 17:58:49 Integrated Voltage Measurement... 17:58:58 Voltage Offset Correction: v_off_ini = -129.317 uV, v_off_fin = -114.018 uV 17:58:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.937 uVs 17:59:00 I2X Average and RMS of Measurements VT = -118.815 +- 7.365 uVs I2X = 10.931 +- 0.678 uTm^2 17:59:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:59:05 Integrated Voltage Measurement... 17:59:14 Voltage Offset Correction: v_off_ini = -131.782 uV, v_off_fin = -129.806 uV 17:59:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.418 uVs 17:59:14 Integrated Voltage Measurement... 17:59:23 Voltage Offset Correction: v_off_ini = -117.453 uV, v_off_fin = -111.553 uV 17:59:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.570 uVs 17:59:23 Integrated Voltage Measurement... 17:59:32 Voltage Offset Correction: v_off_ini = -103.644 uV, v_off_fin = -112.309 uV 17:59:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.959 uVs 17:59:32 Integrated Voltage Measurement... 17:59:41 Voltage Offset Correction: v_off_ini = -104.916 uV, v_off_fin = -109.170 uV 17:59:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.549 uVs 17:59:41 Integrated Voltage Measurement... 17:59:50 Voltage Offset Correction: v_off_ini = -104.852 uV, v_off_fin = -110.999 uV 17:59:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.081 uVs 17:59:50 Integrated Voltage Measurement... 17:59:59 Voltage Offset Correction: v_off_ini = -122.172 uV, v_off_fin = -104.898 uV 17:59:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.529 uVs 18:00:02 I2Y Average and RMS of Measurements VT = -249.684 +- 4.358 uVs I2Y = -22.971 +- 0.401 uTm^2 18:00:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:00:10 Integrated Voltage Measurement... 18:00:19 Voltage Offset Correction: v_off_ini = -118.311 uV, v_off_fin = -115.335 uV 18:00:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.168 uVs 18:00:19 Integrated Voltage Measurement... 18:00:28 Voltage Offset Correction: v_off_ini = -113.751 uV, v_off_fin = -108.813 uV 18:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.118 uVs 18:00:28 Integrated Voltage Measurement... 18:00:37 Voltage Offset Correction: v_off_ini = -130.515 uV, v_off_fin = -119.508 uV 18:00:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.305 uVs 18:00:37 Integrated Voltage Measurement... 18:00:46 Voltage Offset Correction: v_off_ini = -123.502 uV, v_off_fin = -105.624 uV 18:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.182 uVs 18:00:46 Integrated Voltage Measurement... 18:00:55 Voltage Offset Correction: v_off_ini = -111.475 uV, v_off_fin = -119.823 uV 18:00:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.106 uVs 18:00:55 Integrated Voltage Measurement... 18:01:04 Voltage Offset Correction: v_off_ini = -107.712 uV, v_off_fin = -114.226 uV 18:01:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.725 uVs 18:01:09 I1X Average and RMS of Measurements VT = -128.934 +- 6.910 uVs I1X = 25.787 +- 1.382 uTm 18:01:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:01:15 Integrated Voltage Measurement... 18:01:24 Voltage Offset Correction: v_off_ini = -123.951 uV, v_off_fin = -120.990 uV 18:01:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.513 uVs 18:01:24 Integrated Voltage Measurement... 18:01:33 Voltage Offset Correction: v_off_ini = -112.827 uV, v_off_fin = -109.353 uV 18:01:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.183 uVs 18:01:33 Integrated Voltage Measurement... 18:01:42 Voltage Offset Correction: v_off_ini = -103.195 uV, v_off_fin = -128.470 uV 18:01:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.505 uVs 18:01:42 Integrated Voltage Measurement... 18:01:51 Voltage Offset Correction: v_off_ini = -115.940 uV, v_off_fin = -108.764 uV 18:01:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.584 uVs 18:01:51 Integrated Voltage Measurement... 18:02:00 Voltage Offset Correction: v_off_ini = -103.435 uV, v_off_fin = -124.375 uV 18:02:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.878 uVs 18:02:00 Integrated Voltage Measurement... 18:02:09 Voltage Offset Correction: v_off_ini = -95.982 uV, v_off_fin = -92.187 uV 18:02:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.173 uVs 18:02:14 I1Y Average and RMS of Measurements VT = -207.473 +- 4.923 uVs I1Y = -41.495 +- 0.985 uTm 18:02:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:02:19 Integrated Voltage Measurement... 18:02:28 Voltage Offset Correction: v_off_ini = -111.362 uV, v_off_fin = -121.132 uV 18:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.557 uVs 18:02:28 Integrated Voltage Measurement... 18:02:37 Voltage Offset Correction: v_off_ini = -93.680 uV, v_off_fin = -93.818 uV 18:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.373 uVs 18:02:37 Integrated Voltage Measurement... 18:02:46 Voltage Offset Correction: v_off_ini = -109.315 uV, v_off_fin = -123.399 uV 18:02:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.845 uVs 18:02:46 Integrated Voltage Measurement... 18:02:55 Voltage Offset Correction: v_off_ini = -96.115 uV, v_off_fin = -94.209 uV 18:02:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.415 uVs 18:02:55 Integrated Voltage Measurement... 18:03:04 Voltage Offset Correction: v_off_ini = -124.379 uV, v_off_fin = -130.101 uV 18:03:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.656 uVs 18:03:04 Integrated Voltage Measurement... 18:03:13 Voltage Offset Correction: v_off_ini = -112.234 uV, v_off_fin = -106.419 uV 18:03:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.781 uVs 18:03:16 I2X Average and RMS of Measurements VT = -106.605 +- 3.717 uVs I2X = 9.808 +- 0.342 uTm^2 18:03:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:03:21 Integrated Voltage Measurement... 18:03:30 Voltage Offset Correction: v_off_ini = -105.219 uV, v_off_fin = -113.787 uV 18:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.129 uVs 18:03:30 Integrated Voltage Measurement... 18:03:39 Voltage Offset Correction: v_off_ini = -105.472 uV, v_off_fin = -105.402 uV 18:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.857 uVs 18:03:39 Integrated Voltage Measurement... 18:03:48 Voltage Offset Correction: v_off_ini = -99.759 uV, v_off_fin = -98.730 uV 18:03:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.433 uVs 18:03:48 Integrated Voltage Measurement... 18:03:57 Voltage Offset Correction: v_off_ini = -99.907 uV, v_off_fin = -91.203 uV 18:03:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.994 uVs 18:03:57 Integrated Voltage Measurement... 18:04:06 Voltage Offset Correction: v_off_ini = -89.931 uV, v_off_fin = -88.020 uV 18:04:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.924 uVs 18:04:06 Integrated Voltage Measurement... 18:04:15 Voltage Offset Correction: v_off_ini = -85.301 uV, v_off_fin = -98.968 uV 18:04:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.344 uVs 18:04:17 I2Y Average and RMS of Measurements VT = -245.113 +- 5.585 uVs I2Y = -22.550 +- 0.514 uTm^2 18:04:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:04:26 Integrated Voltage Measurement... 18:04:34 Voltage Offset Correction: v_off_ini = -98.694 uV, v_off_fin = -95.839 uV 18:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.279 uVs 18:04:35 Integrated Voltage Measurement... 18:04:43 Voltage Offset Correction: v_off_ini = -99.203 uV, v_off_fin = -110.163 uV 18:04:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.361 uVs 18:04:44 Integrated Voltage Measurement... 18:04:53 Voltage Offset Correction: v_off_ini = -104.861 uV, v_off_fin = -94.669 uV 18:04:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.019 uVs 18:04:53 Integrated Voltage Measurement... 18:05:02 Voltage Offset Correction: v_off_ini = -100.187 uV, v_off_fin = -92.926 uV 18:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.699 uVs 18:05:02 Integrated Voltage Measurement... 18:05:11 Voltage Offset Correction: v_off_ini = -106.174 uV, v_off_fin = -113.847 uV 18:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.424 uVs 18:05:11 Integrated Voltage Measurement... 18:05:20 Voltage Offset Correction: v_off_ini = -119.312 uV, v_off_fin = -110.440 uV 18:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.146 uVs 18:05:24 I1X Average and RMS of Measurements VT = -108.988 +- 9.598 uVs I1X = 21.798 +- 1.920 uTm 18:05:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:05:31 Integrated Voltage Measurement... 18:05:39 Voltage Offset Correction: v_off_ini = -125.847 uV, v_off_fin = -134.091 uV 18:05:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.909 uVs 18:05:40 Integrated Voltage Measurement... 18:05:48 Voltage Offset Correction: v_off_ini = -123.672 uV, v_off_fin = -102.382 uV 18:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.375 uVs 18:05:48 Integrated Voltage Measurement... 18:05:57 Voltage Offset Correction: v_off_ini = -115.906 uV, v_off_fin = -147.459 uV 18:05:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.201 uVs 18:05:57 Integrated Voltage Measurement... 18:06:06 Voltage Offset Correction: v_off_ini = -126.977 uV, v_off_fin = -117.653 uV 18:06:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.875 uVs 18:06:06 Integrated Voltage Measurement... 18:06:15 Voltage Offset Correction: v_off_ini = -132.118 uV, v_off_fin = -132.702 uV 18:06:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.534 uVs 18:06:15 Integrated Voltage Measurement... 18:06:24 Voltage Offset Correction: v_off_ini = -126.630 uV, v_off_fin = -106.889 uV 18:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.549 uVs 18:06:29 I1Y Average and RMS of Measurements VT = -206.240 +- 6.630 uVs I1Y = -41.247 +- 1.324 uTm 18:06:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:06:34 Integrated Voltage Measurement... 18:06:43 Voltage Offset Correction: v_off_ini = -132.318 uV, v_off_fin = -120.099 uV 18:06:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.270 uVs 18:06:43 Integrated Voltage Measurement... 18:06:52 Voltage Offset Correction: v_off_ini = -114.393 uV, v_off_fin = -113.081 uV 18:06:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.527 uVs 18:06:52 Integrated Voltage Measurement... 18:07:01 Voltage Offset Correction: v_off_ini = -116.004 uV, v_off_fin = -124.414 uV 18:07:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.452 uVs 18:07:01 Integrated Voltage Measurement... 18:07:10 Voltage Offset Correction: v_off_ini = -118.236 uV, v_off_fin = -110.260 uV 18:07:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.429 uVs 18:07:10 Integrated Voltage Measurement... 18:07:19 Voltage Offset Correction: v_off_ini = -107.070 uV, v_off_fin = -123.570 uV 18:07:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.255 uVs 18:07:19 Integrated Voltage Measurement... 18:07:28 Voltage Offset Correction: v_off_ini = -114.789 uV, v_off_fin = -104.112 uV 18:07:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.414 uVs 18:07:30 I2X Average and RMS of Measurements VT = -97.891 +- 5.179 uVs I2X = 9.006 +- 0.477 uTm^2 18:07:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:07:35 Integrated Voltage Measurement... 18:07:44 Voltage Offset Correction: v_off_ini = -125.631 uV, v_off_fin = -121.498 uV 18:07:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.431 uVs 18:07:44 Integrated Voltage Measurement... 18:07:53 Voltage Offset Correction: v_off_ini = -123.135 uV, v_off_fin = -122.538 uV 18:07:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.506 uVs 18:07:53 Integrated Voltage Measurement... 18:08:02 Voltage Offset Correction: v_off_ini = -111.813 uV, v_off_fin = -104.256 uV 18:08:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -253.772 uVs 18:08:02 Integrated Voltage Measurement... 18:08:11 Voltage Offset Correction: v_off_ini = -108.342 uV, v_off_fin = -111.418 uV 18:08:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.478 uVs 18:08:11 Integrated Voltage Measurement... 18:08:20 Voltage Offset Correction: v_off_ini = -112.020 uV, v_off_fin = -120.857 uV 18:08:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.160 uVs 18:08:21 Integrated Voltage Measurement... 18:08:29 Voltage Offset Correction: v_off_ini = -113.295 uV, v_off_fin = -121.583 uV 18:08:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.437 uVs 18:08:32 I2Y Average and RMS of Measurements VT = -257.297 +- 2.765 uVs I2Y = -23.672 +- 0.254 uTm^2 18:08:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:08:40 Integrated Voltage Measurement... 18:08:49 Voltage Offset Correction: v_off_ini = -115.184 uV, v_off_fin = -116.590 uV 18:08:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.683 uVs 18:08:49 Integrated Voltage Measurement... 18:08:58 Voltage Offset Correction: v_off_ini = -121.536 uV, v_off_fin = -121.564 uV 18:08:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.532 uVs 18:08:58 Integrated Voltage Measurement... 18:09:07 Voltage Offset Correction: v_off_ini = -132.792 uV, v_off_fin = -145.655 uV 18:09:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.924 uVs 18:09:07 Integrated Voltage Measurement... 18:09:16 Voltage Offset Correction: v_off_ini = -134.944 uV, v_off_fin = -130.503 uV 18:09:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.687 uVs 18:09:16 Integrated Voltage Measurement... 18:09:25 Voltage Offset Correction: v_off_ini = -145.768 uV, v_off_fin = -142.804 uV 18:09:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.500 uVs 18:09:25 Integrated Voltage Measurement... 18:09:34 Voltage Offset Correction: v_off_ini = -137.384 uV, v_off_fin = -122.672 uV 18:09:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.472 uVs 18:09:38 I1X Average and RMS of Measurements VT = -94.300 +- 11.209 uVs I1X = 18.860 +- 2.241 uTm 18:09:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:09:45 Integrated Voltage Measurement... 18:09:54 Voltage Offset Correction: v_off_ini = -128.991 uV, v_off_fin = -162.135 uV 18:09:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.921 uVs 18:09:54 Integrated Voltage Measurement... 18:10:03 Voltage Offset Correction: v_off_ini = -143.503 uV, v_off_fin = -143.738 uV 18:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.997 uVs 18:10:03 Integrated Voltage Measurement... 18:10:12 Voltage Offset Correction: v_off_ini = -143.695 uV, v_off_fin = -154.224 uV 18:10:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.834 uVs 18:10:12 Integrated Voltage Measurement... 18:10:21 Voltage Offset Correction: v_off_ini = -146.793 uV, v_off_fin = -125.955 uV 18:10:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.365 uVs 18:10:21 Integrated Voltage Measurement... 18:10:30 Voltage Offset Correction: v_off_ini = -123.706 uV, v_off_fin = -149.590 uV 18:10:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.517 uVs 18:10:30 Integrated Voltage Measurement... 18:10:39 Voltage Offset Correction: v_off_ini = -148.757 uV, v_off_fin = -136.848 uV 18:10:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.337 uVs 18:10:43 I1Y Average and RMS of Measurements VT = -209.995 +- 2.989 uVs I1Y = -41.996 +- 0.597 uTm 18:10:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:10:48 Integrated Voltage Measurement... 18:10:57 Voltage Offset Correction: v_off_ini = -135.456 uV, v_off_fin = -139.874 uV 18:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.683 uVs 18:10:57 Integrated Voltage Measurement... 18:11:06 Voltage Offset Correction: v_off_ini = -137.285 uV, v_off_fin = -142.464 uV 18:11:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.309 uVs 18:11:06 Integrated Voltage Measurement... 18:11:15 Voltage Offset Correction: v_off_ini = -148.992 uV, v_off_fin = -155.739 uV 18:11:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -73.856 uVs 18:11:15 Integrated Voltage Measurement... 18:11:24 Voltage Offset Correction: v_off_ini = -160.329 uV, v_off_fin = -151.526 uV 18:11:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.705 uVs 18:11:24 Integrated Voltage Measurement... 18:11:33 Voltage Offset Correction: v_off_ini = -148.515 uV, v_off_fin = -158.667 uV 18:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.475 uVs 18:11:34 Integrated Voltage Measurement... 18:11:42 Voltage Offset Correction: v_off_ini = -145.050 uV, v_off_fin = -140.651 uV 18:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.771 uVs 18:11:45 I2X Average and RMS of Measurements VT = -78.967 +- 3.809 uVs I2X = 7.265 +- 0.350 uTm^2 18:11:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:11:50 Integrated Voltage Measurement... 18:11:59 Voltage Offset Correction: v_off_ini = -145.376 uV, v_off_fin = -146.937 uV 18:11:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.693 uVs 18:11:59 Integrated Voltage Measurement... 18:12:08 Voltage Offset Correction: v_off_ini = -142.106 uV, v_off_fin = -136.361 uV 18:12:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.327 uVs 18:12:08 Integrated Voltage Measurement... 18:12:17 Voltage Offset Correction: v_off_ini = -160.991 uV, v_off_fin = -158.217 uV 18:12:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.392 uVs 18:12:17 Integrated Voltage Measurement... 18:12:26 Voltage Offset Correction: v_off_ini = -153.850 uV, v_off_fin = -153.827 uV 18:12:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.126 uVs 18:12:26 Integrated Voltage Measurement... 18:12:35 Voltage Offset Correction: v_off_ini = -156.996 uV, v_off_fin = -150.791 uV 18:12:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.829 uVs 18:12:35 Integrated Voltage Measurement... 18:12:44 Voltage Offset Correction: v_off_ini = -161.775 uV, v_off_fin = -148.303 uV 18:12:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.314 uVs 18:12:47 I2Y Average and RMS of Measurements VT = -261.280 +- 7.506 uVs I2Y = -24.038 +- 0.691 uTm^2 18:13:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:13:08 Integrated Voltage Measurement... 18:13:17 Voltage Offset Correction: v_off_ini = -156.978 uV, v_off_fin = -155.669 uV 18:13:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.743 uVs 18:13:17 Integrated Voltage Measurement... 18:13:26 Voltage Offset Correction: v_off_ini = -143.516 uV, v_off_fin = -150.400 uV 18:13:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.914 uVs 18:13:26 Integrated Voltage Measurement... 18:13:35 Voltage Offset Correction: v_off_ini = -156.652 uV, v_off_fin = -156.510 uV 18:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.359 uVs 18:13:35 Integrated Voltage Measurement... 18:13:44 Voltage Offset Correction: v_off_ini = -151.521 uV, v_off_fin = -160.213 uV 18:13:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.119 uVs 18:13:44 Integrated Voltage Measurement... 18:13:53 Voltage Offset Correction: v_off_ini = -150.172 uV, v_off_fin = -165.055 uV 18:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.913 uVs 18:13:53 Integrated Voltage Measurement... 18:14:02 Voltage Offset Correction: v_off_ini = -164.899 uV, v_off_fin = -160.938 uV 18:14:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.569 uVs 18:14:06 I1X Average and RMS of Measurements VT = -137.436 +- 7.476 uVs I1X = 27.488 +- 1.496 uTm 18:14:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:14:13 Integrated Voltage Measurement... 18:14:22 Voltage Offset Correction: v_off_ini = -162.320 uV, v_off_fin = -174.851 uV 18:14:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.027 uVs 18:14:22 Integrated Voltage Measurement... 18:14:31 Voltage Offset Correction: v_off_ini = -162.037 uV, v_off_fin = -160.740 uV 18:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.953 uVs 18:14:31 Integrated Voltage Measurement... 18:14:40 Voltage Offset Correction: v_off_ini = -168.253 uV, v_off_fin = -179.257 uV 18:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.868 uVs 18:14:40 Integrated Voltage Measurement... 18:14:49 Voltage Offset Correction: v_off_ini = -171.538 uV, v_off_fin = -156.391 uV 18:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.013 uVs 18:14:49 Integrated Voltage Measurement... 18:14:58 Voltage Offset Correction: v_off_ini = -159.429 uV, v_off_fin = -167.127 uV 18:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.861 uVs 18:14:58 Integrated Voltage Measurement... 18:15:07 Voltage Offset Correction: v_off_ini = -157.067 uV, v_off_fin = -144.948 uV 18:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.996 uVs 18:15:11 I1Y Average and RMS of Measurements VT = -180.120 +- 2.972 uVs I1Y = -36.024 +- 0.594 uTm 18:15:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:15:19 Integrated Voltage Measurement... 18:15:27 Voltage Offset Correction: v_off_ini = -158.631 uV, v_off_fin = -169.454 uV 18:15:28 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -135.249 uVs 18:15:28 Integrated Voltage Measurement... 18:15:37 Voltage Offset Correction: v_off_ini = -150.505 uV, v_off_fin = -153.968 uV 18:15:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.745 uVs 18:15:37 Integrated Voltage Measurement... 18:15:46 Voltage Offset Correction: v_off_ini = -161.367 uV, v_off_fin = -181.520 uV 18:15:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.825 uVs 18:15:46 Integrated Voltage Measurement... 18:15:55 Voltage Offset Correction: v_off_ini = -154.302 uV, v_off_fin = -135.175 uV 18:15:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.797 uVs 18:15:55 Integrated Voltage Measurement... 18:16:04 Voltage Offset Correction: v_off_ini = -154.782 uV, v_off_fin = -162.404 uV 18:16:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.661 uVs 18:16:04 Integrated Voltage Measurement... 18:16:13 Voltage Offset Correction: v_off_ini = -167.427 uV, v_off_fin = -149.007 uV 18:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.839 uVs 18:16:15 I2X Average and RMS of Measurements VT = -113.353 +- 3.343 uVs I2X = 10.428 +- 0.307 uTm^2 18:16:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:16:23 Integrated Voltage Measurement... 18:16:32 Voltage Offset Correction: v_off_ini = -153.546 uV, v_off_fin = -157.660 uV 18:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.645 uVs 18:16:32 Integrated Voltage Measurement... 18:16:41 Voltage Offset Correction: v_off_ini = -161.245 uV, v_off_fin = -160.005 uV 18:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.938 uVs 18:16:41 Integrated Voltage Measurement... 18:16:50 Voltage Offset Correction: v_off_ini = -165.967 uV, v_off_fin = -150.487 uV 18:16:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.475 uVs 18:16:50 Integrated Voltage Measurement... 18:16:59 Voltage Offset Correction: v_off_ini = -167.896 uV, v_off_fin = -172.627 uV 18:16:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.675 uVs 18:16:59 Integrated Voltage Measurement... 18:17:08 Voltage Offset Correction: v_off_ini = -167.494 uV, v_off_fin = -164.000 uV 18:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.616 uVs 18:17:08 Integrated Voltage Measurement... 18:17:17 Voltage Offset Correction: v_off_ini = -164.633 uV, v_off_fin = -162.417 uV 18:17:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.143 uVs 18:17:19 I2Y Average and RMS of Measurements VT = -207.249 +- 7.135 uVs I2Y = -19.067 +- 0.656 uTm^2 18:17:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:17:28 Integrated Voltage Measurement... 18:17:37 Voltage Offset Correction: v_off_ini = -159.245 uV, v_off_fin = -166.330 uV 18:17:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.094 uVs 18:17:37 Integrated Voltage Measurement... 18:17:46 Voltage Offset Correction: v_off_ini = -148.420 uV, v_off_fin = -145.439 uV 18:17:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.587 uVs 18:17:46 Integrated Voltage Measurement... 18:17:55 Voltage Offset Correction: v_off_ini = -153.582 uV, v_off_fin = -161.812 uV 18:17:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -136.423 uVs 18:17:55 Integrated Voltage Measurement... 18:18:04 Voltage Offset Correction: v_off_ini = -147.890 uV, v_off_fin = -157.953 uV 18:18:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.726 uVs 18:18:04 Integrated Voltage Measurement... 18:18:13 Voltage Offset Correction: v_off_ini = -155.335 uV, v_off_fin = -162.504 uV 18:18:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.840 uVs 18:18:13 Integrated Voltage Measurement... 18:18:22 Voltage Offset Correction: v_off_ini = -160.491 uV, v_off_fin = -154.487 uV 18:18:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.617 uVs 18:18:26 I1X Average and RMS of Measurements VT = -130.381 +- 7.262 uVs I1X = 26.077 +- 1.452 uTm 18:18:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:18:33 Integrated Voltage Measurement... 18:18:42 Voltage Offset Correction: v_off_ini = -160.693 uV, v_off_fin = -177.106 uV 18:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.024 uVs 18:18:42 Integrated Voltage Measurement... 18:18:51 Voltage Offset Correction: v_off_ini = -171.273 uV, v_off_fin = -152.205 uV 18:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.757 uVs 18:18:51 Integrated Voltage Measurement... 18:19:00 Voltage Offset Correction: v_off_ini = -153.568 uV, v_off_fin = -165.631 uV 18:19:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.837 uVs 18:19:00 Integrated Voltage Measurement... 18:19:09 Voltage Offset Correction: v_off_ini = -148.923 uV, v_off_fin = -158.898 uV 18:19:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.492 uVs 18:19:09 Integrated Voltage Measurement... 18:19:18 Voltage Offset Correction: v_off_ini = -159.415 uV, v_off_fin = -177.568 uV 18:19:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.552 uVs 18:19:18 Integrated Voltage Measurement... 18:19:27 Voltage Offset Correction: v_off_ini = -171.537 uV, v_off_fin = -156.017 uV 18:19:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.862 uVs 18:19:31 I1Y Average and RMS of Measurements VT = -199.421 +- 3.400 uVs I1Y = -39.884 +- 0.680 uTm 18:19:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:19:39 Integrated Voltage Measurement... 18:19:48 Voltage Offset Correction: v_off_ini = -159.001 uV, v_off_fin = -159.376 uV 18:19:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.103 uVs 18:19:48 Integrated Voltage Measurement... 18:19:57 Voltage Offset Correction: v_off_ini = -153.380 uV, v_off_fin = -149.543 uV 18:19:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.416 uVs 18:19:57 Integrated Voltage Measurement... 18:20:06 Voltage Offset Correction: v_off_ini = -159.712 uV, v_off_fin = -164.251 uV 18:20:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.246 uVs 18:20:06 Integrated Voltage Measurement... 18:20:15 Voltage Offset Correction: v_off_ini = -147.971 uV, v_off_fin = -153.041 uV 18:20:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.393 uVs 18:20:15 Integrated Voltage Measurement... 18:20:24 Voltage Offset Correction: v_off_ini = -149.541 uV, v_off_fin = -168.480 uV 18:20:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.827 uVs 18:20:24 Integrated Voltage Measurement... 18:20:33 Voltage Offset Correction: v_off_ini = -159.581 uV, v_off_fin = -159.191 uV 18:20:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.860 uVs 18:20:36 I2X Average and RMS of Measurements VT = -110.808 +- 5.794 uVs I2X = 10.194 +- 0.533 uTm^2 18:20:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:20:43 Integrated Voltage Measurement... 18:20:52 Voltage Offset Correction: v_off_ini = -143.200 uV, v_off_fin = -146.885 uV 18:20:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.147 uVs 18:20:52 Integrated Voltage Measurement... 18:21:01 Voltage Offset Correction: v_off_ini = -156.184 uV, v_off_fin = -155.907 uV 18:21:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.382 uVs 18:21:01 Integrated Voltage Measurement... 18:21:10 Voltage Offset Correction: v_off_ini = -143.367 uV, v_off_fin = -156.760 uV 18:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.623 uVs 18:21:10 Integrated Voltage Measurement... 18:21:19 Voltage Offset Correction: v_off_ini = -165.219 uV, v_off_fin = -153.495 uV 18:21:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.561 uVs 18:21:20 Integrated Voltage Measurement... 18:21:29 Voltage Offset Correction: v_off_ini = -158.149 uV, v_off_fin = -159.655 uV 18:21:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -230.272 uVs 18:21:29 Integrated Voltage Measurement... 18:21:38 Voltage Offset Correction: v_off_ini = -174.695 uV, v_off_fin = -161.603 uV 18:21:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.405 uVs 18:21:40 I2Y Average and RMS of Measurements VT = -235.565 +- 6.017 uVs I2Y = -21.672 +- 0.554 uTm^2 18:21:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:21:49 Integrated Voltage Measurement... 18:21:58 Voltage Offset Correction: v_off_ini = -158.192 uV, v_off_fin = -167.935 uV 18:21:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.163 uVs 18:21:58 Integrated Voltage Measurement... 18:22:07 Voltage Offset Correction: v_off_ini = -164.443 uV, v_off_fin = -159.821 uV 18:22:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.867 uVs 18:22:07 Integrated Voltage Measurement... 18:22:16 Voltage Offset Correction: v_off_ini = -162.703 uV, v_off_fin = -158.182 uV 18:22:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.093 uVs 18:22:16 Integrated Voltage Measurement... 18:22:25 Voltage Offset Correction: v_off_ini = -148.017 uV, v_off_fin = -150.773 uV 18:22:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.814 uVs 18:22:25 Integrated Voltage Measurement... 18:22:34 Voltage Offset Correction: v_off_ini = -151.146 uV, v_off_fin = -152.712 uV 18:22:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.022 uVs 18:22:34 Integrated Voltage Measurement... 18:22:43 Voltage Offset Correction: v_off_ini = -151.275 uV, v_off_fin = -152.232 uV 18:22:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 128.933 uVs 18:22:47 I1X Average and RMS of Measurements VT = -133.149 +- 6.380 uVs I1X = 26.631 +- 1.276 uTm 18:22:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:22:54 Integrated Voltage Measurement... 18:23:03 Voltage Offset Correction: v_off_ini = -139.992 uV, v_off_fin = -154.848 uV 18:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.339 uVs 18:23:03 Integrated Voltage Measurement... 18:23:12 Voltage Offset Correction: v_off_ini = -149.279 uV, v_off_fin = -133.156 uV 18:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.001 uVs 18:23:12 Integrated Voltage Measurement... 18:23:21 Voltage Offset Correction: v_off_ini = -131.665 uV, v_off_fin = -156.928 uV 18:23:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.927 uVs 18:23:21 Integrated Voltage Measurement... 18:23:30 Voltage Offset Correction: v_off_ini = -146.562 uV, v_off_fin = -130.569 uV 18:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.674 uVs 18:23:30 Integrated Voltage Measurement... 18:23:39 Voltage Offset Correction: v_off_ini = -153.147 uV, v_off_fin = -165.353 uV 18:23:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.389 uVs 18:23:39 Integrated Voltage Measurement... 18:23:48 Voltage Offset Correction: v_off_ini = -157.115 uV, v_off_fin = -151.657 uV 18:23:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.316 uVs 18:23:52 I1Y Average and RMS of Measurements VT = -212.274 +- 1.549 uVs I1Y = -42.455 +- 0.310 uTm 18:23:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:24:00 Integrated Voltage Measurement... 18:24:09 Voltage Offset Correction: v_off_ini = -132.951 uV, v_off_fin = -153.258 uV 18:24:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.487 uVs 18:24:09 Integrated Voltage Measurement... 18:24:18 Voltage Offset Correction: v_off_ini = -148.656 uV, v_off_fin = -137.832 uV 18:24:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 109.152 uVs 18:24:18 Integrated Voltage Measurement... 18:24:27 Voltage Offset Correction: v_off_ini = -146.396 uV, v_off_fin = -156.970 uV 18:24:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.907 uVs 18:24:27 Integrated Voltage Measurement... 18:24:36 Voltage Offset Correction: v_off_ini = -144.146 uV, v_off_fin = -146.287 uV 18:24:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.111 uVs 18:24:36 Integrated Voltage Measurement... 18:24:45 Voltage Offset Correction: v_off_ini = -151.031 uV, v_off_fin = -160.748 uV 18:24:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.847 uVs 18:24:45 Integrated Voltage Measurement... 18:24:54 Voltage Offset Correction: v_off_ini = -156.251 uV, v_off_fin = -161.245 uV 18:24:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.934 uVs 18:24:57 I2X Average and RMS of Measurements VT = -122.073 +- 4.246 uVs I2X = 11.231 +- 0.390 uTm^2 18:25:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:25:04 Integrated Voltage Measurement... 18:25:13 Voltage Offset Correction: v_off_ini = -162.934 uV, v_off_fin = -160.431 uV 18:25:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.879 uVs 18:25:13 Integrated Voltage Measurement... 18:25:22 Voltage Offset Correction: v_off_ini = -151.338 uV, v_off_fin = -157.167 uV 18:25:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.099 uVs 18:25:22 Integrated Voltage Measurement... 18:25:31 Voltage Offset Correction: v_off_ini = -159.737 uV, v_off_fin = -160.173 uV 18:25:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.702 uVs 18:25:31 Integrated Voltage Measurement... 18:25:40 Voltage Offset Correction: v_off_ini = -172.210 uV, v_off_fin = -166.042 uV 18:25:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.749 uVs 18:25:40 Integrated Voltage Measurement... 18:25:49 Voltage Offset Correction: v_off_ini = -159.325 uV, v_off_fin = -165.704 uV 18:25:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.321 uVs 18:25:49 Integrated Voltage Measurement... 18:25:58 Voltage Offset Correction: v_off_ini = -160.698 uV, v_off_fin = -158.144 uV 18:25:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.930 uVs 18:26:01 I2Y Average and RMS of Measurements VT = -253.280 +- 0.669 uVs I2Y = -23.302 +- 0.062 uTm^2 18:26:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:26:10 Integrated Voltage Measurement... 18:26:19 Voltage Offset Correction: v_off_ini = -186.004 uV, v_off_fin = -184.243 uV 18:26:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.668 uVs 18:26:19 Integrated Voltage Measurement... 18:26:28 Voltage Offset Correction: v_off_ini = -175.135 uV, v_off_fin = -175.688 uV 18:26:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.345 uVs 18:26:28 Integrated Voltage Measurement... 18:26:37 Voltage Offset Correction: v_off_ini = -174.873 uV, v_off_fin = -180.933 uV 18:26:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.477 uVs 18:26:37 Integrated Voltage Measurement... 18:26:46 Voltage Offset Correction: v_off_ini = -170.142 uV, v_off_fin = -165.132 uV 18:26:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.414 uVs 18:26:46 Integrated Voltage Measurement... 18:26:55 Voltage Offset Correction: v_off_ini = -165.974 uV, v_off_fin = -168.084 uV 18:26:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.007 uVs 18:26:55 Integrated Voltage Measurement... 18:27:04 Voltage Offset Correction: v_off_ini = -165.248 uV, v_off_fin = -159.394 uV 18:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.008 uVs 18:27:08 I1X Average and RMS of Measurements VT = -138.487 +- 7.438 uVs I1X = 27.697 +- 1.488 uTm 18:27:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:27:15 Integrated Voltage Measurement... 18:27:24 Voltage Offset Correction: v_off_ini = -149.388 uV, v_off_fin = -169.368 uV 18:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -234.277 uVs 18:27:24 Integrated Voltage Measurement... 18:27:33 Voltage Offset Correction: v_off_ini = -158.060 uV, v_off_fin = -142.556 uV 18:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.404 uVs 18:27:33 Integrated Voltage Measurement... 18:27:42 Voltage Offset Correction: v_off_ini = -161.007 uV, v_off_fin = -168.355 uV 18:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.360 uVs 18:27:42 Integrated Voltage Measurement... 18:27:51 Voltage Offset Correction: v_off_ini = -160.629 uV, v_off_fin = -141.772 uV 18:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.998 uVs 18:27:51 Integrated Voltage Measurement... 18:28:00 Voltage Offset Correction: v_off_ini = -160.081 uV, v_off_fin = -174.871 uV 18:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.629 uVs 18:28:00 Integrated Voltage Measurement... 18:28:09 Voltage Offset Correction: v_off_ini = -167.091 uV, v_off_fin = -154.081 uV 18:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.590 uVs 18:28:13 I1Y Average and RMS of Measurements VT = -237.210 +- 0.754 uVs I1Y = -47.443 +- 0.150 uTm 18:28:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:28:21 Integrated Voltage Measurement... 18:28:30 Voltage Offset Correction: v_off_ini = -184.551 uV, v_off_fin = -186.130 uV 18:28:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.927 uVs 18:28:30 Integrated Voltage Measurement... 18:28:39 Voltage Offset Correction: v_off_ini = -174.772 uV, v_off_fin = -171.075 uV 18:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.327 uVs 18:28:39 Integrated Voltage Measurement... 18:28:48 Voltage Offset Correction: v_off_ini = -172.610 uV, v_off_fin = -181.859 uV 18:28:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.203 uVs 18:28:48 Integrated Voltage Measurement... 18:28:57 Voltage Offset Correction: v_off_ini = -167.693 uV, v_off_fin = -157.173 uV 18:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.841 uVs 18:28:57 Integrated Voltage Measurement... 18:29:06 Voltage Offset Correction: v_off_ini = -165.404 uV, v_off_fin = -175.940 uV 18:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.048 uVs 18:29:06 Integrated Voltage Measurement... 18:29:15 Voltage Offset Correction: v_off_ini = -179.451 uV, v_off_fin = -181.797 uV 18:29:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.704 uVs 18:29:17 I2X Average and RMS of Measurements VT = -125.675 +- 2.680 uVs I2X = 11.562 +- 0.246 uTm^2 18:29:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:29:25 Integrated Voltage Measurement... 18:29:34 Voltage Offset Correction: v_off_ini = -177.711 uV, v_off_fin = -194.333 uV 18:29:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.254 uVs 18:29:34 Integrated Voltage Measurement... 18:29:43 Voltage Offset Correction: v_off_ini = -189.594 uV, v_off_fin = -185.875 uV 18:29:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.089 uVs 18:29:43 Integrated Voltage Measurement... 18:29:52 Voltage Offset Correction: v_off_ini = -196.072 uV, v_off_fin = -188.941 uV 18:29:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.894 uVs 18:29:52 Integrated Voltage Measurement... 18:30:01 Voltage Offset Correction: v_off_ini = -191.814 uV, v_off_fin = -191.829 uV 18:30:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.120 uVs 18:30:01 Integrated Voltage Measurement... 18:30:10 Voltage Offset Correction: v_off_ini = -184.303 uV, v_off_fin = -178.747 uV 18:30:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.572 uVs 18:30:10 Integrated Voltage Measurement... 18:30:19 Voltage Offset Correction: v_off_ini = -186.737 uV, v_off_fin = -192.035 uV 18:30:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.323 uVs 18:30:21 I2Y Average and RMS of Measurements VT = -271.209 +- 2.160 uVs I2Y = -24.951 +- 0.199 uTm^2 18:30:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:30:30 Integrated Voltage Measurement... 18:30:39 Voltage Offset Correction: v_off_ini = -187.657 uV, v_off_fin = -188.308 uV 18:30:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -146.288 uVs 18:30:39 Integrated Voltage Measurement... 18:30:48 Voltage Offset Correction: v_off_ini = -180.700 uV, v_off_fin = -191.870 uV 18:30:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.191 uVs 18:30:48 Integrated Voltage Measurement... 18:30:57 Voltage Offset Correction: v_off_ini = -207.695 uV, v_off_fin = -200.001 uV 18:30:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.226 uVs 18:30:57 Integrated Voltage Measurement... 18:31:06 Voltage Offset Correction: v_off_ini = -187.547 uV, v_off_fin = -198.849 uV 18:31:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.778 uVs 18:31:06 Integrated Voltage Measurement... 18:31:15 Voltage Offset Correction: v_off_ini = -183.604 uV, v_off_fin = -190.874 uV 18:31:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.186 uVs 18:31:15 Integrated Voltage Measurement... 18:31:24 Voltage Offset Correction: v_off_ini = -187.968 uV, v_off_fin = -187.570 uV 18:31:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.129 uVs 18:31:28 I1X Average and RMS of Measurements VT = -135.800 +- 3.126 uVs I1X = 27.161 +- 0.626 uTm 18:31:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:31:35 Integrated Voltage Measurement... 18:31:44 Voltage Offset Correction: v_off_ini = -172.791 uV, v_off_fin = -178.557 uV 18:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.246 uVs 18:31:44 Integrated Voltage Measurement... 18:31:53 Voltage Offset Correction: v_off_ini = -171.005 uV, v_off_fin = -167.267 uV 18:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.954 uVs 18:31:53 Integrated Voltage Measurement... 18:32:02 Voltage Offset Correction: v_off_ini = -182.036 uV, v_off_fin = -187.420 uV 18:32:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.088 uVs 18:32:02 Integrated Voltage Measurement... 18:32:11 Voltage Offset Correction: v_off_ini = -171.394 uV, v_off_fin = -166.946 uV 18:32:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.475 uVs 18:32:11 Integrated Voltage Measurement... 18:32:20 Voltage Offset Correction: v_off_ini = -186.998 uV, v_off_fin = -185.224 uV 18:32:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.897 uVs 18:32:20 Integrated Voltage Measurement... 18:32:29 Voltage Offset Correction: v_off_ini = -182.729 uV, v_off_fin = -170.067 uV 18:32:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.208 uVs 18:32:33 I1Y Average and RMS of Measurements VT = -251.145 +- 4.956 uVs I1Y = -50.229 +- 0.991 uTm 18:32:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:32:41 Integrated Voltage Measurement... 18:32:50 Voltage Offset Correction: v_off_ini = -194.616 uV, v_off_fin = -185.167 uV 18:32:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -110.541 uVs 18:32:50 Integrated Voltage Measurement... 18:32:59 Voltage Offset Correction: v_off_ini = -167.412 uV, v_off_fin = -162.016 uV 18:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.502 uVs 18:32:59 Integrated Voltage Measurement... 18:33:08 Voltage Offset Correction: v_off_ini = -171.964 uV, v_off_fin = -194.558 uV 18:33:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.732 uVs 18:33:08 Integrated Voltage Measurement... 18:33:17 Voltage Offset Correction: v_off_ini = -172.329 uV, v_off_fin = -179.366 uV 18:33:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.272 uVs 18:33:17 Integrated Voltage Measurement... 18:33:26 Voltage Offset Correction: v_off_ini = -189.472 uV, v_off_fin = -181.531 uV 18:33:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.636 uVs 18:33:26 Integrated Voltage Measurement... 18:33:35 Voltage Offset Correction: v_off_ini = -182.802 uV, v_off_fin = -155.323 uV 18:33:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.069 uVs 18:33:38 I2X Average and RMS of Measurements VT = -130.292 +- 4.656 uVs I2X = 11.987 +- 0.429 uTm^2 18:33:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:33:45 Integrated Voltage Measurement... 18:33:54 Voltage Offset Correction: v_off_ini = -167.614 uV, v_off_fin = -168.828 uV 18:33:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.396 uVs 18:33:54 Integrated Voltage Measurement... 18:34:03 Voltage Offset Correction: v_off_ini = -158.390 uV, v_off_fin = -154.019 uV 18:34:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.881 uVs 18:34:03 Integrated Voltage Measurement... 18:34:12 Voltage Offset Correction: v_off_ini = -166.903 uV, v_off_fin = -168.599 uV 18:34:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.969 uVs 18:34:12 Integrated Voltage Measurement... 18:34:21 Voltage Offset Correction: v_off_ini = -162.688 uV, v_off_fin = -156.507 uV 18:34:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.251 uVs 18:34:21 Integrated Voltage Measurement... 18:34:30 Voltage Offset Correction: v_off_ini = -159.851 uV, v_off_fin = -162.617 uV 18:34:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.280 uVs 18:34:30 Integrated Voltage Measurement... 18:34:39 Voltage Offset Correction: v_off_ini = -160.287 uV, v_off_fin = -168.539 uV 18:34:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.044 uVs 18:34:42 I2Y Average and RMS of Measurements VT = -287.137 +- 4.431 uVs I2Y = -26.417 +- 0.408 uTm^2 18:34:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:34:54 Integrated Voltage Measurement... 18:35:03 Voltage Offset Correction: v_off_ini = -158.266 uV, v_off_fin = -165.112 uV 18:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.150 uVs 18:35:03 Integrated Voltage Measurement... 18:35:12 Voltage Offset Correction: v_off_ini = -166.927 uV, v_off_fin = -154.076 uV 18:35:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.092 uVs 18:35:12 Integrated Voltage Measurement... 18:35:21 Voltage Offset Correction: v_off_ini = -157.080 uV, v_off_fin = -165.300 uV 18:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.705 uVs 18:35:21 Integrated Voltage Measurement... 18:35:30 Voltage Offset Correction: v_off_ini = -158.987 uV, v_off_fin = -155.915 uV 18:35:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.901 uVs 18:35:30 Integrated Voltage Measurement... 18:35:39 Voltage Offset Correction: v_off_ini = -161.939 uV, v_off_fin = -157.679 uV 18:35:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.866 uVs 18:35:39 Integrated Voltage Measurement... 18:35:48 Voltage Offset Correction: v_off_ini = -152.937 uV, v_off_fin = -138.645 uV 18:35:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.707 uVs 18:35:52 I1X Average and RMS of Measurements VT = -145.737 +- 2.835 uVs I1X = 29.148 +- 0.567 uTm 18:35:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:35:59 Integrated Voltage Measurement... 18:36:08 Voltage Offset Correction: v_off_ini = -156.769 uV, v_off_fin = -178.496 uV 18:36:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.002 uVs 18:36:08 Integrated Voltage Measurement... 18:36:17 Voltage Offset Correction: v_off_ini = -150.809 uV, v_off_fin = -152.276 uV 18:36:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.145 uVs 18:36:17 Integrated Voltage Measurement... 18:36:26 Voltage Offset Correction: v_off_ini = -159.006 uV, v_off_fin = -169.726 uV 18:36:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.853 uVs 18:36:26 Integrated Voltage Measurement... 18:36:35 Voltage Offset Correction: v_off_ini = -169.479 uV, v_off_fin = -154.359 uV 18:36:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.429 uVs 18:36:35 Integrated Voltage Measurement... 18:36:44 Voltage Offset Correction: v_off_ini = -181.382 uV, v_off_fin = -184.410 uV 18:36:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.093 uVs 18:36:44 Integrated Voltage Measurement... 18:36:53 Voltage Offset Correction: v_off_ini = -166.780 uV, v_off_fin = -146.177 uV 18:36:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.977 uVs 18:36:57 I1Y Average and RMS of Measurements VT = -206.750 +- 2.892 uVs I1Y = -41.350 +- 0.578 uTm 18:36:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:37:02 Integrated Voltage Measurement... 18:37:11 Voltage Offset Correction: v_off_ini = -171.969 uV, v_off_fin = -171.950 uV 18:37:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.765 uVs 18:37:11 Integrated Voltage Measurement... 18:37:20 Voltage Offset Correction: v_off_ini = -168.145 uV, v_off_fin = -163.377 uV 18:37:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.483 uVs 18:37:20 Integrated Voltage Measurement... 18:37:29 Voltage Offset Correction: v_off_ini = -161.321 uV, v_off_fin = -171.334 uV 18:37:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.959 uVs 18:37:29 Integrated Voltage Measurement... 18:37:38 Voltage Offset Correction: v_off_ini = -147.278 uV, v_off_fin = -150.054 uV 18:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.694 uVs 18:37:38 Integrated Voltage Measurement... 18:37:47 Voltage Offset Correction: v_off_ini = -161.751 uV, v_off_fin = -179.042 uV 18:37:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -106.210 uVs 18:37:47 Integrated Voltage Measurement... 18:37:56 Voltage Offset Correction: v_off_ini = -157.862 uV, v_off_fin = -132.497 uV 18:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.491 uVs 18:37:58 I2X Average and RMS of Measurements VT = -126.600 +- 9.795 uVs I2X = 11.648 +- 0.901 uTm^2 18:38:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:38:04 Integrated Voltage Measurement... 18:38:13 Voltage Offset Correction: v_off_ini = -149.650 uV, v_off_fin = -148.643 uV 18:38:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.384 uVs 18:38:13 Integrated Voltage Measurement... 18:38:22 Voltage Offset Correction: v_off_ini = -161.145 uV, v_off_fin = -165.602 uV 18:38:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.296 uVs 18:38:22 Integrated Voltage Measurement... 18:38:31 Voltage Offset Correction: v_off_ini = -158.876 uV, v_off_fin = -167.562 uV 18:38:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.730 uVs 18:38:31 Integrated Voltage Measurement... 18:38:40 Voltage Offset Correction: v_off_ini = -167.036 uV, v_off_fin = -159.553 uV 18:38:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.657 uVs 18:38:40 Integrated Voltage Measurement... 18:38:49 Voltage Offset Correction: v_off_ini = -160.863 uV, v_off_fin = -142.090 uV 18:38:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.680 uVs 18:38:49 Integrated Voltage Measurement... 18:38:58 Voltage Offset Correction: v_off_ini = -161.252 uV, v_off_fin = -158.953 uV 18:38:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.712 uVs 18:39:00 I2Y Average and RMS of Measurements VT = -244.576 +- 5.406 uVs I2Y = -22.501 +- 0.497 uTm^2 18:39:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:39:08 Integrated Voltage Measurement... 18:39:17 Voltage Offset Correction: v_off_ini = -148.119 uV, v_off_fin = -152.692 uV 18:39:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.549 uVs 18:39:17 Integrated Voltage Measurement... 18:39:26 Voltage Offset Correction: v_off_ini = -141.482 uV, v_off_fin = -138.184 uV 18:39:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.948 uVs 18:39:26 Integrated Voltage Measurement... 18:39:35 Voltage Offset Correction: v_off_ini = -143.814 uV, v_off_fin = -158.592 uV 18:39:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.315 uVs 18:39:36 Integrated Voltage Measurement... 18:39:44 Voltage Offset Correction: v_off_ini = -141.188 uV, v_off_fin = -142.944 uV 18:39:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.234 uVs 18:39:45 Integrated Voltage Measurement... 18:39:53 Voltage Offset Correction: v_off_ini = -134.793 uV, v_off_fin = -153.989 uV 18:39:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.954 uVs 18:39:54 Integrated Voltage Measurement... 18:40:02 Voltage Offset Correction: v_off_ini = -165.587 uV, v_off_fin = -160.053 uV 18:40:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 117.481 uVs 18:40:07 I1X Average and RMS of Measurements VT = -131.913 +- 4.386 uVs I1X = 26.384 +- 0.876 uTm 18:40:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:40:14 Integrated Voltage Measurement... 18:40:22 Voltage Offset Correction: v_off_ini = -163.860 uV, v_off_fin = -174.612 uV 18:40:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.512 uVs 18:40:23 Integrated Voltage Measurement... 18:40:31 Voltage Offset Correction: v_off_ini = -170.995 uV, v_off_fin = -174.651 uV 18:40:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.669 uVs 18:40:32 Integrated Voltage Measurement... 18:40:40 Voltage Offset Correction: v_off_ini = -169.004 uV, v_off_fin = -179.557 uV 18:40:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.055 uVs 18:40:41 Integrated Voltage Measurement... 18:40:49 Voltage Offset Correction: v_off_ini = -178.266 uV, v_off_fin = -164.024 uV 18:40:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.422 uVs 18:40:50 Integrated Voltage Measurement... 18:40:58 Voltage Offset Correction: v_off_ini = -154.184 uV, v_off_fin = -172.656 uV 18:40:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.114 uVs 18:40:59 Integrated Voltage Measurement... 18:41:07 Voltage Offset Correction: v_off_ini = -177.852 uV, v_off_fin = -149.817 uV 18:41:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.573 uVs 18:41:12 I1Y Average and RMS of Measurements VT = -217.558 +- 3.159 uVs I1Y = -43.512 +- 0.632 uTm 18:41:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:41:17 Integrated Voltage Measurement... 18:41:26 Voltage Offset Correction: v_off_ini = -147.222 uV, v_off_fin = -163.646 uV 18:41:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.235 uVs 18:41:26 Integrated Voltage Measurement... 18:41:35 Voltage Offset Correction: v_off_ini = -177.368 uV, v_off_fin = -164.390 uV 18:41:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.746 uVs 18:41:35 Integrated Voltage Measurement... 18:41:44 Voltage Offset Correction: v_off_ini = -172.437 uV, v_off_fin = -191.847 uV 18:41:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.415 uVs 18:41:44 Integrated Voltage Measurement... 18:41:53 Voltage Offset Correction: v_off_ini = -182.840 uV, v_off_fin = -164.204 uV 18:41:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.331 uVs 18:41:53 Integrated Voltage Measurement... 18:42:02 Voltage Offset Correction: v_off_ini = -165.684 uV, v_off_fin = -184.637 uV 18:42:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.994 uVs 18:42:02 Integrated Voltage Measurement... 18:42:11 Voltage Offset Correction: v_off_ini = -166.591 uV, v_off_fin = -175.418 uV 18:42:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.157 uVs 18:42:13 I2X Average and RMS of Measurements VT = -133.480 +- 2.761 uVs I2X = 12.280 +- 0.254 uTm^2 18:42:16 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:42:19 Integrated Voltage Measurement... 18:42:28 Voltage Offset Correction: v_off_ini = -195.309 uV, v_off_fin = -197.046 uV 18:42:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.526 uVs 18:42:28 Integrated Voltage Measurement... 18:42:37 Voltage Offset Correction: v_off_ini = -179.434 uV, v_off_fin = -175.937 uV 18:42:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.078 uVs 18:42:37 Integrated Voltage Measurement... 18:42:46 Voltage Offset Correction: v_off_ini = -175.340 uV, v_off_fin = -189.997 uV 18:42:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.172 uVs 18:42:46 Integrated Voltage Measurement... 18:42:55 Voltage Offset Correction: v_off_ini = -194.318 uV, v_off_fin = -184.700 uV 18:42:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.150 uVs 18:42:55 Integrated Voltage Measurement... 18:43:04 Voltage Offset Correction: v_off_ini = -186.290 uV, v_off_fin = -182.219 uV 18:43:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.855 uVs 18:43:04 Integrated Voltage Measurement... 18:43:13 Voltage Offset Correction: v_off_ini = -182.263 uV, v_off_fin = -183.600 uV 18:43:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.694 uVs 18:43:15 I2Y Average and RMS of Measurements VT = -248.913 +- 2.836 uVs I2Y = -22.900 +- 0.261 uTm^2 18:43:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:43:24 Integrated Voltage Measurement... 18:43:33 Voltage Offset Correction: v_off_ini = -179.226 uV, v_off_fin = -191.201 uV 18:43:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -131.950 uVs 18:43:33 Integrated Voltage Measurement... 18:43:42 Voltage Offset Correction: v_off_ini = -199.732 uV, v_off_fin = -190.002 uV 18:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 133.088 uVs 18:43:42 Integrated Voltage Measurement... 18:43:51 Voltage Offset Correction: v_off_ini = -182.073 uV, v_off_fin = -191.048 uV 18:43:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.581 uVs 18:43:51 Integrated Voltage Measurement... 18:44:00 Voltage Offset Correction: v_off_ini = -193.210 uV, v_off_fin = -187.525 uV 18:44:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.430 uVs 18:44:00 Integrated Voltage Measurement... 18:44:09 Voltage Offset Correction: v_off_ini = -189.107 uV, v_off_fin = -195.797 uV 18:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.885 uVs 18:44:09 Integrated Voltage Measurement... 18:44:18 Voltage Offset Correction: v_off_ini = -176.286 uV, v_off_fin = -180.989 uV 18:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.353 uVs 18:44:22 I1X Average and RMS of Measurements VT = -132.381 +- 2.201 uVs I1X = 26.478 +- 0.441 uTm 18:44:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:44:29 Integrated Voltage Measurement... 18:44:38 Voltage Offset Correction: v_off_ini = -183.132 uV, v_off_fin = -200.653 uV 18:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.747 uVs 18:44:38 Integrated Voltage Measurement... 18:44:47 Voltage Offset Correction: v_off_ini = -189.137 uV, v_off_fin = -191.770 uV 18:44:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.110 uVs 18:44:47 Integrated Voltage Measurement... 18:44:56 Voltage Offset Correction: v_off_ini = -197.809 uV, v_off_fin = -210.054 uV 18:44:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.627 uVs 18:44:56 Integrated Voltage Measurement... 18:45:05 Voltage Offset Correction: v_off_ini = -191.009 uV, v_off_fin = -198.391 uV 18:45:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.886 uVs 18:45:05 Integrated Voltage Measurement... 18:45:14 Voltage Offset Correction: v_off_ini = -192.803 uV, v_off_fin = -195.735 uV 18:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.541 uVs 18:45:14 Integrated Voltage Measurement... 18:45:23 Voltage Offset Correction: v_off_ini = -170.596 uV, v_off_fin = -176.820 uV 18:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.518 uVs 18:45:27 I1Y Average and RMS of Measurements VT = -219.905 +- 6.666 uVs I1Y = -43.981 +- 1.333 uTm 18:45:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:45:32 Integrated Voltage Measurement... 18:45:41 Voltage Offset Correction: v_off_ini = -202.466 uV, v_off_fin = -216.192 uV 18:45:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -121.082 uVs 18:45:41 Integrated Voltage Measurement... 18:45:50 Voltage Offset Correction: v_off_ini = -198.923 uV, v_off_fin = -189.186 uV 18:45:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.816 uVs 18:45:50 Integrated Voltage Measurement... 18:45:59 Voltage Offset Correction: v_off_ini = -195.610 uV, v_off_fin = -204.935 uV 18:45:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.942 uVs 18:45:59 Integrated Voltage Measurement... 18:46:08 Voltage Offset Correction: v_off_ini = -209.957 uV, v_off_fin = -201.331 uV 18:46:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.489 uVs 18:46:08 Integrated Voltage Measurement... 18:46:17 Voltage Offset Correction: v_off_ini = -200.536 uV, v_off_fin = -212.238 uV 18:46:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.691 uVs 18:46:17 Integrated Voltage Measurement... 18:46:26 Voltage Offset Correction: v_off_ini = -201.637 uV, v_off_fin = -191.765 uV 18:46:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.446 uVs 18:46:28 I2X Average and RMS of Measurements VT = -117.078 +- 4.252 uVs I2X = 10.771 +- 0.391 uTm^2 18:46:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:46:34 Integrated Voltage Measurement... 18:46:43 Voltage Offset Correction: v_off_ini = -195.211 uV, v_off_fin = -187.523 uV 18:46:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.221 uVs 18:46:43 Integrated Voltage Measurement... 18:46:52 Voltage Offset Correction: v_off_ini = -178.907 uV, v_off_fin = -179.058 uV 18:46:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.236 uVs 18:46:52 Integrated Voltage Measurement... 18:47:01 Voltage Offset Correction: v_off_ini = -186.420 uV, v_off_fin = -191.789 uV 18:47:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.300 uVs 18:47:01 Integrated Voltage Measurement... 18:47:10 Voltage Offset Correction: v_off_ini = -199.814 uV, v_off_fin = -203.516 uV 18:47:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.194 uVs 18:47:10 Integrated Voltage Measurement... 18:47:19 Voltage Offset Correction: v_off_ini = -187.589 uV, v_off_fin = -196.496 uV 18:47:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.888 uVs 18:47:19 Integrated Voltage Measurement... 18:47:28 Voltage Offset Correction: v_off_ini = -186.099 uV, v_off_fin = -180.092 uV 18:47:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.213 uVs 18:47:30 I2Y Average and RMS of Measurements VT = -246.342 +- 4.790 uVs I2Y = -22.663 +- 0.441 uTm^2 18:47:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:47:38 Integrated Voltage Measurement... 18:47:47 Voltage Offset Correction: v_off_ini = -173.357 uV, v_off_fin = -175.463 uV 18:47:47 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -116.199 uVs 18:47:47 Integrated Voltage Measurement... 18:47:56 Voltage Offset Correction: v_off_ini = -171.438 uV, v_off_fin = -177.817 uV 18:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 121.198 uVs 18:47:56 Integrated Voltage Measurement... 18:48:05 Voltage Offset Correction: v_off_ini = -189.182 uV, v_off_fin = -201.297 uV 18:48:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.248 uVs 18:48:05 Integrated Voltage Measurement... 18:48:14 Voltage Offset Correction: v_off_ini = -192.043 uV, v_off_fin = -198.081 uV 18:48:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.582 uVs 18:48:14 Integrated Voltage Measurement... 18:48:23 Voltage Offset Correction: v_off_ini = -198.702 uV, v_off_fin = -193.919 uV 18:48:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.716 uVs 18:48:23 Integrated Voltage Measurement... 18:48:32 Voltage Offset Correction: v_off_ini = -195.040 uV, v_off_fin = -199.818 uV 18:48:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.188 uVs 18:48:37 I1X Average and RMS of Measurements VT = -116.355 +- 8.947 uVs I1X = 23.273 +- 1.789 uTm 18:48:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:48:43 Integrated Voltage Measurement... 18:48:52 Voltage Offset Correction: v_off_ini = -200.678 uV, v_off_fin = -216.138 uV 18:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.880 uVs 18:48:52 Integrated Voltage Measurement... 18:49:01 Voltage Offset Correction: v_off_ini = -199.767 uV, v_off_fin = -196.586 uV 18:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.561 uVs 18:49:01 Integrated Voltage Measurement... 18:49:10 Voltage Offset Correction: v_off_ini = -215.478 uV, v_off_fin = -222.810 uV 18:49:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.171 uVs 18:49:10 Integrated Voltage Measurement... 18:49:19 Voltage Offset Correction: v_off_ini = -198.753 uV, v_off_fin = -190.978 uV 18:49:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.854 uVs 18:49:19 Integrated Voltage Measurement... 18:49:28 Voltage Offset Correction: v_off_ini = -193.779 uV, v_off_fin = -217.754 uV 18:49:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.549 uVs 18:49:28 Integrated Voltage Measurement... 18:49:37 Voltage Offset Correction: v_off_ini = -195.533 uV, v_off_fin = -191.435 uV 18:49:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.778 uVs 18:49:42 I1Y Average and RMS of Measurements VT = -207.965 +- 4.629 uVs I1Y = -41.593 +- 0.926 uTm 18:49:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:49:47 Integrated Voltage Measurement... 18:49:56 Voltage Offset Correction: v_off_ini = -223.151 uV, v_off_fin = -224.306 uV 18:49:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.238 uVs 18:49:56 Integrated Voltage Measurement... 18:50:05 Voltage Offset Correction: v_off_ini = -203.990 uV, v_off_fin = -198.663 uV 18:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.990 uVs 18:50:05 Integrated Voltage Measurement... 18:50:14 Voltage Offset Correction: v_off_ini = -205.525 uV, v_off_fin = -204.289 uV 18:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.847 uVs 18:50:14 Integrated Voltage Measurement... 18:50:23 Voltage Offset Correction: v_off_ini = -200.289 uV, v_off_fin = -191.697 uV 18:50:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.336 uVs 18:50:23 Integrated Voltage Measurement... 18:50:32 Voltage Offset Correction: v_off_ini = -194.249 uV, v_off_fin = -197.869 uV 18:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.584 uVs 18:50:32 Integrated Voltage Measurement... 18:50:41 Voltage Offset Correction: v_off_ini = -192.793 uV, v_off_fin = -180.208 uV 18:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.139 uVs 18:50:43 I2X Average and RMS of Measurements VT = -104.689 +- 7.452 uVs I2X = 9.632 +- 0.686 uTm^2 18:50:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:50:48 Integrated Voltage Measurement... 18:50:57 Voltage Offset Correction: v_off_ini = -182.856 uV, v_off_fin = -185.222 uV 18:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.413 uVs 18:50:57 Integrated Voltage Measurement... 18:51:06 Voltage Offset Correction: v_off_ini = -180.978 uV, v_off_fin = -184.650 uV 18:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.432 uVs 18:51:06 Integrated Voltage Measurement... 18:51:15 Voltage Offset Correction: v_off_ini = -192.015 uV, v_off_fin = -188.243 uV 18:51:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.269 uVs 18:51:15 Integrated Voltage Measurement... 18:51:24 Voltage Offset Correction: v_off_ini = -197.596 uV, v_off_fin = -191.733 uV 18:51:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.791 uVs 18:51:24 Integrated Voltage Measurement... 18:51:33 Voltage Offset Correction: v_off_ini = -186.421 uV, v_off_fin = -198.104 uV 18:51:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.516 uVs 18:51:33 Integrated Voltage Measurement... 18:51:42 Voltage Offset Correction: v_off_ini = -196.516 uV, v_off_fin = -192.578 uV 18:51:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.906 uVs 18:51:45 I2Y Average and RMS of Measurements VT = -255.388 +- 5.283 uVs I2Y = -23.496 +- 0.486 uTm^2 18:51:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:51:53 Integrated Voltage Measurement... 18:52:02 Voltage Offset Correction: v_off_ini = -188.134 uV, v_off_fin = -191.389 uV 18:52:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.617 uVs 18:52:02 Integrated Voltage Measurement... 18:52:11 Voltage Offset Correction: v_off_ini = -176.282 uV, v_off_fin = -168.026 uV 18:52:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.700 uVs 18:52:11 Integrated Voltage Measurement... 18:52:20 Voltage Offset Correction: v_off_ini = -181.050 uV, v_off_fin = -194.758 uV 18:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.566 uVs 18:52:20 Integrated Voltage Measurement... 18:52:29 Voltage Offset Correction: v_off_ini = -168.828 uV, v_off_fin = -184.261 uV 18:52:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.823 uVs 18:52:29 Integrated Voltage Measurement... 18:52:38 Voltage Offset Correction: v_off_ini = -183.741 uV, v_off_fin = -201.599 uV 18:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.004 uVs 18:52:38 Integrated Voltage Measurement... 18:52:47 Voltage Offset Correction: v_off_ini = -187.676 uV, v_off_fin = -187.787 uV 18:52:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.524 uVs 18:52:51 I1X Average and RMS of Measurements VT = -98.706 +- 1.042 uVs I1X = 19.741 +- 0.208 uTm 18:52:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:52:58 Integrated Voltage Measurement... 18:53:07 Voltage Offset Correction: v_off_ini = -208.062 uV, v_off_fin = -208.018 uV 18:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -190.713 uVs 18:53:07 Integrated Voltage Measurement... 18:53:16 Voltage Offset Correction: v_off_ini = -210.586 uV, v_off_fin = -200.100 uV 18:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.706 uVs 18:53:16 Integrated Voltage Measurement... 18:53:25 Voltage Offset Correction: v_off_ini = -208.900 uV, v_off_fin = -222.021 uV 18:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.809 uVs 18:53:25 Integrated Voltage Measurement... 18:53:34 Voltage Offset Correction: v_off_ini = -204.982 uV, v_off_fin = -199.614 uV 18:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.208 uVs 18:53:34 Integrated Voltage Measurement... 18:53:43 Voltage Offset Correction: v_off_ini = -203.105 uV, v_off_fin = -209.403 uV 18:53:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.226 uVs 18:53:43 Integrated Voltage Measurement... 18:53:52 Voltage Offset Correction: v_off_ini = -192.680 uV, v_off_fin = -184.915 uV 18:53:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.198 uVs 18:53:56 I1Y Average and RMS of Measurements VT = -201.643 +- 2.185 uVs I1Y = -40.329 +- 0.436 uTm 18:53:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:54:01 Integrated Voltage Measurement... 18:54:10 Voltage Offset Correction: v_off_ini = -200.271 uV, v_off_fin = -201.479 uV 18:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.295 uVs 18:54:10 Integrated Voltage Measurement... 18:54:19 Voltage Offset Correction: v_off_ini = -201.559 uV, v_off_fin = -201.589 uV 18:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.319 uVs 18:54:19 Integrated Voltage Measurement... 18:54:28 Voltage Offset Correction: v_off_ini = -200.284 uV, v_off_fin = -207.311 uV 18:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.497 uVs 18:54:28 Integrated Voltage Measurement... 18:54:37 Voltage Offset Correction: v_off_ini = -196.883 uV, v_off_fin = -180.842 uV 18:54:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.146 uVs 18:54:37 Integrated Voltage Measurement... 18:54:46 Voltage Offset Correction: v_off_ini = -200.142 uV, v_off_fin = -202.954 uV 18:54:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.606 uVs 18:54:46 Integrated Voltage Measurement... 18:54:55 Voltage Offset Correction: v_off_ini = -198.092 uV, v_off_fin = -191.100 uV 18:54:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.738 uVs 18:54:58 I2X Average and RMS of Measurements VT = -88.600 +- 3.346 uVs I2X = 8.151 +- 0.308 uTm^2 18:55:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:55:03 Integrated Voltage Measurement... 18:55:12 Voltage Offset Correction: v_off_ini = -200.392 uV, v_off_fin = -197.337 uV 18:55:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.778 uVs 18:55:12 Integrated Voltage Measurement... 18:55:21 Voltage Offset Correction: v_off_ini = -207.170 uV, v_off_fin = -193.267 uV 18:55:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.761 uVs 18:55:21 Integrated Voltage Measurement... 18:55:30 Voltage Offset Correction: v_off_ini = -198.086 uV, v_off_fin = -200.527 uV 18:55:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.370 uVs 18:55:30 Integrated Voltage Measurement... 18:55:39 Voltage Offset Correction: v_off_ini = -203.057 uV, v_off_fin = -195.545 uV 18:55:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.195 uVs 18:55:39 Integrated Voltage Measurement... 18:55:48 Voltage Offset Correction: v_off_ini = -199.882 uV, v_off_fin = -193.171 uV 18:55:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.457 uVs 18:55:48 Integrated Voltage Measurement... 18:55:57 Voltage Offset Correction: v_off_ini = -197.905 uV, v_off_fin = -200.671 uV 18:55:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.096 uVs 18:55:59 I2Y Average and RMS of Measurements VT = -254.609 +- 5.868 uVs I2Y = -23.424 +- 0.540 uTm^2 18:56:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:56:21 Integrated Voltage Measurement... 18:56:30 Voltage Offset Correction: v_off_ini = -206.532 uV, v_off_fin = -206.358 uV 18:56:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.523 uVs 18:56:30 Integrated Voltage Measurement... 18:56:39 Voltage Offset Correction: v_off_ini = -204.964 uV, v_off_fin = -205.819 uV 18:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.895 uVs 18:56:39 Integrated Voltage Measurement... 18:56:48 Voltage Offset Correction: v_off_ini = -220.026 uV, v_off_fin = -225.767 uV 18:56:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.985 uVs 18:56:48 Integrated Voltage Measurement... 18:56:57 Voltage Offset Correction: v_off_ini = -223.561 uV, v_off_fin = -220.646 uV 18:56:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.725 uVs 18:56:57 Integrated Voltage Measurement... 18:57:06 Voltage Offset Correction: v_off_ini = -223.424 uV, v_off_fin = -218.765 uV 18:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.378 uVs 18:57:06 Integrated Voltage Measurement... 18:57:15 Voltage Offset Correction: v_off_ini = -208.041 uV, v_off_fin = -210.589 uV 18:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.109 uVs 18:57:19 I1X Average and RMS of Measurements VT = -133.602 +- 6.512 uVs I1X = 26.721 +- 1.303 uTm 18:57:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:57:26 Integrated Voltage Measurement... 18:57:35 Voltage Offset Correction: v_off_ini = -208.624 uV, v_off_fin = -218.487 uV 18:57:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.315 uVs 18:57:35 Integrated Voltage Measurement... 18:57:44 Voltage Offset Correction: v_off_ini = -205.380 uV, v_off_fin = -203.157 uV 18:57:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.336 uVs 18:57:44 Integrated Voltage Measurement... 18:57:53 Voltage Offset Correction: v_off_ini = -219.115 uV, v_off_fin = -224.646 uV 18:57:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.551 uVs 18:57:53 Integrated Voltage Measurement... 18:58:02 Voltage Offset Correction: v_off_ini = -206.617 uV, v_off_fin = -195.497 uV 18:58:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.273 uVs 18:58:02 Integrated Voltage Measurement... 18:58:11 Voltage Offset Correction: v_off_ini = -213.548 uV, v_off_fin = -223.237 uV 18:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.155 uVs 18:58:11 Integrated Voltage Measurement... 18:58:20 Voltage Offset Correction: v_off_ini = -206.472 uV, v_off_fin = -200.236 uV 18:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.939 uVs 18:58:24 I1Y Average and RMS of Measurements VT = -174.928 +- 4.175 uVs I1Y = -34.986 +- 0.835 uTm 18:58:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:58:32 Integrated Voltage Measurement... 18:58:40 Voltage Offset Correction: v_off_ini = -213.787 uV, v_off_fin = -223.580 uV 18:58:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.737 uVs 18:58:41 Integrated Voltage Measurement... 18:58:49 Voltage Offset Correction: v_off_ini = -214.086 uV, v_off_fin = -195.118 uV 18:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.842 uVs 18:58:50 Integrated Voltage Measurement... 18:58:59 Voltage Offset Correction: v_off_ini = -213.107 uV, v_off_fin = -233.918 uV 18:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.994 uVs 18:58:59 Integrated Voltage Measurement... 18:59:08 Voltage Offset Correction: v_off_ini = -215.585 uV, v_off_fin = -195.962 uV 18:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.405 uVs 18:59:08 Integrated Voltage Measurement... 18:59:17 Voltage Offset Correction: v_off_ini = -207.381 uV, v_off_fin = -220.277 uV 18:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.961 uVs 18:59:17 Integrated Voltage Measurement... 18:59:26 Voltage Offset Correction: v_off_ini = -215.792 uV, v_off_fin = -201.038 uV 18:59:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.650 uVs 18:59:28 I2X Average and RMS of Measurements VT = -112.598 +- 2.340 uVs I2X = 10.359 +- 0.215 uTm^2 18:59:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:59:36 Integrated Voltage Measurement... 18:59:45 Voltage Offset Correction: v_off_ini = -215.550 uV, v_off_fin = -221.486 uV 18:59:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.522 uVs 18:59:45 Integrated Voltage Measurement... 18:59:54 Voltage Offset Correction: v_off_ini = -228.791 uV, v_off_fin = -225.117 uV 18:59:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.620 uVs 18:59:54 Integrated Voltage Measurement... 19:00:03 Voltage Offset Correction: v_off_ini = -217.990 uV, v_off_fin = -210.898 uV 19:00:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.046 uVs 19:00:03 Integrated Voltage Measurement... 19:00:12 Voltage Offset Correction: v_off_ini = -231.346 uV, v_off_fin = -214.585 uV 19:00:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.860 uVs 19:00:12 Integrated Voltage Measurement... 19:00:21 Voltage Offset Correction: v_off_ini = -215.391 uV, v_off_fin = -215.136 uV 19:00:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.955 uVs 19:00:21 Integrated Voltage Measurement... 19:00:30 Voltage Offset Correction: v_off_ini = -221.840 uV, v_off_fin = -214.939 uV 19:00:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.891 uVs 19:00:32 I2Y Average and RMS of Measurements VT = -213.482 +- 4.602 uVs I2Y = -19.640 +- 0.423 uTm^2 19:00:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:00:41 Integrated Voltage Measurement... 19:00:50 Voltage Offset Correction: v_off_ini = -203.851 uV, v_off_fin = -204.243 uV 19:00:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.442 uVs 19:00:50 Integrated Voltage Measurement... 19:00:59 Voltage Offset Correction: v_off_ini = -202.391 uV, v_off_fin = -196.457 uV 19:00:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.986 uVs 19:00:59 Integrated Voltage Measurement... 19:01:08 Voltage Offset Correction: v_off_ini = -200.240 uV, v_off_fin = -196.247 uV 19:01:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.950 uVs 19:01:08 Integrated Voltage Measurement... 19:01:17 Voltage Offset Correction: v_off_ini = -198.730 uV, v_off_fin = -196.633 uV 19:01:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.467 uVs 19:01:17 Integrated Voltage Measurement... 19:01:26 Voltage Offset Correction: v_off_ini = -191.259 uV, v_off_fin = -194.795 uV 19:01:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.083 uVs 19:01:26 Integrated Voltage Measurement... 19:01:35 Voltage Offset Correction: v_off_ini = -183.920 uV, v_off_fin = -199.040 uV 19:01:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.060 uVs 19:01:39 I1X Average and RMS of Measurements VT = -142.331 +- 5.623 uVs I1X = 28.466 +- 1.125 uTm 19:01:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:01:46 Integrated Voltage Measurement... 19:01:55 Voltage Offset Correction: v_off_ini = -194.299 uV, v_off_fin = -207.950 uV 19:01:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.888 uVs 19:01:55 Integrated Voltage Measurement... 19:02:04 Voltage Offset Correction: v_off_ini = -197.104 uV, v_off_fin = -182.591 uV 19:02:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.770 uVs 19:02:04 Integrated Voltage Measurement... 19:02:13 Voltage Offset Correction: v_off_ini = -194.846 uV, v_off_fin = -185.556 uV 19:02:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.367 uVs 19:02:13 Integrated Voltage Measurement... 19:02:22 Voltage Offset Correction: v_off_ini = -182.950 uV, v_off_fin = -180.701 uV 19:02:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.870 uVs 19:02:22 Integrated Voltage Measurement... 19:02:31 Voltage Offset Correction: v_off_ini = -189.839 uV, v_off_fin = -194.917 uV 19:02:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.182 uVs 19:02:31 Integrated Voltage Measurement... 19:02:40 Voltage Offset Correction: v_off_ini = -201.248 uV, v_off_fin = -180.704 uV 19:02:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.959 uVs 19:02:44 I1Y Average and RMS of Measurements VT = -204.506 +- 1.765 uVs I1Y = -40.901 +- 0.353 uTm 19:02:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:02:52 Integrated Voltage Measurement... 19:03:01 Voltage Offset Correction: v_off_ini = -186.411 uV, v_off_fin = -180.124 uV 19:03:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.972 uVs 19:03:01 Integrated Voltage Measurement... 19:03:10 Voltage Offset Correction: v_off_ini = -169.932 uV, v_off_fin = -164.958 uV 19:03:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.785 uVs 19:03:10 Integrated Voltage Measurement... 19:03:19 Voltage Offset Correction: v_off_ini = -171.476 uV, v_off_fin = -174.295 uV 19:03:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.426 uVs 19:03:19 Integrated Voltage Measurement... 19:03:28 Voltage Offset Correction: v_off_ini = -164.861 uV, v_off_fin = -156.591 uV 19:03:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.313 uVs 19:03:28 Integrated Voltage Measurement... 19:03:37 Voltage Offset Correction: v_off_ini = -163.656 uV, v_off_fin = -167.290 uV 19:03:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.213 uVs 19:03:37 Integrated Voltage Measurement... 19:03:46 Voltage Offset Correction: v_off_ini = -162.481 uV, v_off_fin = -157.070 uV 19:03:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.482 uVs 19:03:49 I2X Average and RMS of Measurements VT = -119.865 +- 7.780 uVs I2X = 11.027 +- 0.716 uTm^2 19:03:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:03:56 Integrated Voltage Measurement... 19:04:05 Voltage Offset Correction: v_off_ini = -176.733 uV, v_off_fin = -179.576 uV 19:04:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.314 uVs 19:04:05 Integrated Voltage Measurement... 19:04:14 Voltage Offset Correction: v_off_ini = -178.441 uV, v_off_fin = -184.955 uV 19:04:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.618 uVs 19:04:14 Integrated Voltage Measurement... 19:04:23 Voltage Offset Correction: v_off_ini = -172.111 uV, v_off_fin = -165.520 uV 19:04:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.299 uVs 19:04:24 Integrated Voltage Measurement... 19:04:32 Voltage Offset Correction: v_off_ini = -173.962 uV, v_off_fin = -176.113 uV 19:04:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.244 uVs 19:04:33 Integrated Voltage Measurement... 19:04:42 Voltage Offset Correction: v_off_ini = -175.086 uV, v_off_fin = -166.687 uV 19:04:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.387 uVs 19:04:42 Integrated Voltage Measurement... 19:04:51 Voltage Offset Correction: v_off_ini = -159.924 uV, v_off_fin = -167.431 uV 19:04:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.882 uVs 19:04:53 I2Y Average and RMS of Measurements VT = -232.624 +- 6.608 uVs I2Y = -21.401 +- 0.608 uTm^2 19:04:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:05:02 Integrated Voltage Measurement... 19:05:11 Voltage Offset Correction: v_off_ini = -156.529 uV, v_off_fin = -181.149 uV 19:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.549 uVs 19:05:11 Integrated Voltage Measurement... 19:05:20 Voltage Offset Correction: v_off_ini = -172.147 uV, v_off_fin = -167.151 uV 19:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.797 uVs 19:05:20 Integrated Voltage Measurement... 19:05:29 Voltage Offset Correction: v_off_ini = -188.515 uV, v_off_fin = -183.113 uV 19:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.267 uVs 19:05:29 Integrated Voltage Measurement... 19:05:38 Voltage Offset Correction: v_off_ini = -193.062 uV, v_off_fin = -189.374 uV 19:05:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.211 uVs 19:05:38 Integrated Voltage Measurement... 19:05:47 Voltage Offset Correction: v_off_ini = -190.850 uV, v_off_fin = -203.171 uV 19:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.432 uVs 19:05:47 Integrated Voltage Measurement... 19:05:56 Voltage Offset Correction: v_off_ini = -193.734 uV, v_off_fin = -185.131 uV 19:05:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.145 uVs 19:06:00 I1X Average and RMS of Measurements VT = -140.400 +- 11.379 uVs I1X = 28.080 +- 2.276 uTm 19:06:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:06:07 Integrated Voltage Measurement... 19:06:16 Voltage Offset Correction: v_off_ini = -182.692 uV, v_off_fin = -203.328 uV 19:06:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.175 uVs 19:06:16 Integrated Voltage Measurement... 19:06:25 Voltage Offset Correction: v_off_ini = -205.954 uV, v_off_fin = -198.541 uV 19:06:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.332 uVs 19:06:25 Integrated Voltage Measurement... 19:06:34 Voltage Offset Correction: v_off_ini = -192.729 uV, v_off_fin = -195.422 uV 19:06:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.640 uVs 19:06:34 Integrated Voltage Measurement... 19:06:43 Voltage Offset Correction: v_off_ini = -189.823 uV, v_off_fin = -181.764 uV 19:06:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.691 uVs 19:06:43 Integrated Voltage Measurement... 19:06:52 Voltage Offset Correction: v_off_ini = -185.482 uV, v_off_fin = -184.511 uV 19:06:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.890 uVs 19:06:52 Integrated Voltage Measurement... 19:07:01 Voltage Offset Correction: v_off_ini = -188.048 uV, v_off_fin = -169.587 uV 19:07:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.919 uVs 19:07:05 I1Y Average and RMS of Measurements VT = -211.108 +- 6.451 uVs I1Y = -42.222 +- 1.290 uTm 19:07:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:07:13 Integrated Voltage Measurement... 19:07:22 Voltage Offset Correction: v_off_ini = -192.849 uV, v_off_fin = -208.264 uV 19:07:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -131.769 uVs 19:07:22 Integrated Voltage Measurement... 19:07:31 Voltage Offset Correction: v_off_ini = -183.818 uV, v_off_fin = -177.593 uV 19:07:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.392 uVs 19:07:31 Integrated Voltage Measurement... 19:07:40 Voltage Offset Correction: v_off_ini = -188.663 uV, v_off_fin = -198.230 uV 19:07:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.955 uVs 19:07:40 Integrated Voltage Measurement... 19:07:49 Voltage Offset Correction: v_off_ini = -183.263 uV, v_off_fin = -184.582 uV 19:07:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.403 uVs 19:07:49 Integrated Voltage Measurement... 19:07:58 Voltage Offset Correction: v_off_ini = -182.640 uV, v_off_fin = -184.399 uV 19:07:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.595 uVs 19:07:58 Integrated Voltage Measurement... 19:08:07 Voltage Offset Correction: v_off_ini = -175.761 uV, v_off_fin = -166.501 uV 19:08:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.525 uVs 19:08:09 I2X Average and RMS of Measurements VT = -128.940 +- 4.947 uVs I2X = 11.862 +- 0.456 uTm^2 19:08:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:08:17 Integrated Voltage Measurement... 19:08:26 Voltage Offset Correction: v_off_ini = -149.313 uV, v_off_fin = -160.242 uV 19:08:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.734 uVs 19:08:26 Integrated Voltage Measurement... 19:08:35 Voltage Offset Correction: v_off_ini = -161.733 uV, v_off_fin = -165.664 uV 19:08:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.001 uVs 19:08:35 Integrated Voltage Measurement... 19:08:44 Voltage Offset Correction: v_off_ini = -168.086 uV, v_off_fin = -164.250 uV 19:08:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.551 uVs 19:08:44 Integrated Voltage Measurement... 19:08:53 Voltage Offset Correction: v_off_ini = -163.568 uV, v_off_fin = -162.408 uV 19:08:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.626 uVs 19:08:53 Integrated Voltage Measurement... 19:09:02 Voltage Offset Correction: v_off_ini = -177.531 uV, v_off_fin = -165.442 uV 19:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.725 uVs 19:09:02 Integrated Voltage Measurement... 19:09:11 Voltage Offset Correction: v_off_ini = -150.730 uV, v_off_fin = -157.507 uV 19:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.597 uVs 19:09:14 I2Y Average and RMS of Measurements VT = -244.206 +- 2.560 uVs I2Y = -22.467 +- 0.236 uTm^2 19:09:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:09:23 Integrated Voltage Measurement... 19:09:32 Voltage Offset Correction: v_off_ini = -150.701 uV, v_off_fin = -158.694 uV 19:09:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.644 uVs 19:09:32 Integrated Voltage Measurement... 19:09:41 Voltage Offset Correction: v_off_ini = -152.455 uV, v_off_fin = -156.942 uV 19:09:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.573 uVs 19:09:41 Integrated Voltage Measurement... 19:09:50 Voltage Offset Correction: v_off_ini = -170.778 uV, v_off_fin = -168.018 uV 19:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.776 uVs 19:09:50 Integrated Voltage Measurement... 19:09:59 Voltage Offset Correction: v_off_ini = -149.151 uV, v_off_fin = -161.151 uV 19:09:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.429 uVs 19:09:59 Integrated Voltage Measurement... 19:10:08 Voltage Offset Correction: v_off_ini = -161.877 uV, v_off_fin = -158.589 uV 19:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.463 uVs 19:10:08 Integrated Voltage Measurement... 19:10:17 Voltage Offset Correction: v_off_ini = -147.251 uV, v_off_fin = -147.174 uV 19:10:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.301 uVs 19:10:21 I1X Average and RMS of Measurements VT = -138.698 +- 8.195 uVs I1X = 27.740 +- 1.640 uTm 19:10:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:10:28 Integrated Voltage Measurement... 19:10:37 Voltage Offset Correction: v_off_ini = -147.211 uV, v_off_fin = -161.659 uV 19:10:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.086 uVs 19:10:37 Integrated Voltage Measurement... 19:10:46 Voltage Offset Correction: v_off_ini = -143.989 uV, v_off_fin = -123.887 uV 19:10:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.727 uVs 19:10:46 Integrated Voltage Measurement... 19:10:55 Voltage Offset Correction: v_off_ini = -144.356 uV, v_off_fin = -150.611 uV 19:10:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.050 uVs 19:10:55 Integrated Voltage Measurement... 19:11:04 Voltage Offset Correction: v_off_ini = -150.292 uV, v_off_fin = -132.509 uV 19:11:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.170 uVs 19:11:04 Integrated Voltage Measurement... 19:11:13 Voltage Offset Correction: v_off_ini = -146.099 uV, v_off_fin = -157.972 uV 19:11:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.771 uVs 19:11:13 Integrated Voltage Measurement... 19:11:22 Voltage Offset Correction: v_off_ini = -154.741 uV, v_off_fin = -140.910 uV 19:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.392 uVs 19:11:26 I1Y Average and RMS of Measurements VT = -236.199 +- 3.601 uVs I1Y = -47.240 +- 0.720 uTm 19:11:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:11:34 Integrated Voltage Measurement... 19:11:43 Voltage Offset Correction: v_off_ini = -171.134 uV, v_off_fin = -178.261 uV 19:11:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.934 uVs 19:11:43 Integrated Voltage Measurement... 19:11:52 Voltage Offset Correction: v_off_ini = -159.669 uV, v_off_fin = -166.170 uV 19:11:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.937 uVs 19:11:52 Integrated Voltage Measurement... 19:12:01 Voltage Offset Correction: v_off_ini = -164.875 uV, v_off_fin = -178.154 uV 19:12:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.611 uVs 19:12:01 Integrated Voltage Measurement... 19:12:10 Voltage Offset Correction: v_off_ini = -161.635 uV, v_off_fin = -156.945 uV 19:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.696 uVs 19:12:10 Integrated Voltage Measurement... 19:12:19 Voltage Offset Correction: v_off_ini = -164.229 uV, v_off_fin = -191.446 uV 19:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.709 uVs 19:12:19 Integrated Voltage Measurement... 19:12:28 Voltage Offset Correction: v_off_ini = -167.613 uV, v_off_fin = -164.667 uV 19:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.300 uVs 19:12:30 I2X Average and RMS of Measurements VT = -123.865 +- 1.163 uVs I2X = 11.396 +- 0.107 uTm^2 19:12:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:12:38 Integrated Voltage Measurement... 19:12:47 Voltage Offset Correction: v_off_ini = -178.244 uV, v_off_fin = -180.241 uV 19:12:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.431 uVs 19:12:47 Integrated Voltage Measurement... 19:12:56 Voltage Offset Correction: v_off_ini = -180.276 uV, v_off_fin = -172.392 uV 19:12:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.164 uVs 19:12:56 Integrated Voltage Measurement... 19:13:05 Voltage Offset Correction: v_off_ini = -185.302 uV, v_off_fin = -178.145 uV 19:13:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.640 uVs 19:13:05 Integrated Voltage Measurement... 19:13:14 Voltage Offset Correction: v_off_ini = -178.620 uV, v_off_fin = -163.363 uV 19:13:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.799 uVs 19:13:14 Integrated Voltage Measurement... 19:13:23 Voltage Offset Correction: v_off_ini = -181.067 uV, v_off_fin = -171.111 uV 19:13:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.037 uVs 19:13:23 Integrated Voltage Measurement... 19:13:32 Voltage Offset Correction: v_off_ini = -181.652 uV, v_off_fin = -182.622 uV 19:13:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.389 uVs 19:13:35 I2Y Average and RMS of Measurements VT = -269.410 +- 8.284 uVs I2Y = -24.786 +- 0.762 uTm^2 19:13:39 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:13:43 Integrated Voltage Measurement... 19:13:52 Voltage Offset Correction: v_off_ini = -171.923 uV, v_off_fin = -180.203 uV 19:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.441 uVs 19:13:53 Integrated Voltage Measurement... 19:14:01 Voltage Offset Correction: v_off_ini = -177.919 uV, v_off_fin = -174.345 uV 19:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.569 uVs 19:14:02 Integrated Voltage Measurement... 19:14:11 Voltage Offset Correction: v_off_ini = -166.513 uV, v_off_fin = -174.771 uV 19:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.508 uVs 19:14:11 Integrated Voltage Measurement... 19:14:20 Voltage Offset Correction: v_off_ini = -159.463 uV, v_off_fin = -158.252 uV 19:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.180 uVs 19:14:20 Integrated Voltage Measurement... 19:14:29 Voltage Offset Correction: v_off_ini = -159.428 uV, v_off_fin = -167.829 uV 19:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -157.887 uVs 19:14:29 Integrated Voltage Measurement... 19:14:38 Voltage Offset Correction: v_off_ini = -148.912 uV, v_off_fin = -141.952 uV 19:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.647 uVs 19:14:42 I1X Average and RMS of Measurements VT = -149.205 +- 4.808 uVs I1X = 29.842 +- 0.961 uTm 19:14:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:14:49 Integrated Voltage Measurement... 19:14:58 Voltage Offset Correction: v_off_ini = -142.604 uV, v_off_fin = -164.144 uV 19:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.929 uVs 19:14:58 Integrated Voltage Measurement... 19:15:07 Voltage Offset Correction: v_off_ini = -146.622 uV, v_off_fin = -133.093 uV 19:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.989 uVs 19:15:07 Integrated Voltage Measurement... 19:15:16 Voltage Offset Correction: v_off_ini = -145.162 uV, v_off_fin = -165.066 uV 19:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.475 uVs 19:15:16 Integrated Voltage Measurement... 19:15:25 Voltage Offset Correction: v_off_ini = -145.227 uV, v_off_fin = -132.656 uV 19:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.032 uVs 19:15:25 Integrated Voltage Measurement... 19:15:34 Voltage Offset Correction: v_off_ini = -140.046 uV, v_off_fin = -160.993 uV 19:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.691 uVs 19:15:34 Integrated Voltage Measurement... 19:15:43 Voltage Offset Correction: v_off_ini = -133.209 uV, v_off_fin = -131.312 uV 19:15:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.673 uVs 19:15:47 I1Y Average and RMS of Measurements VT = -244.132 +- 1.143 uVs I1Y = -48.826 +- 0.229 uTm 19:15:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:15:55 Integrated Voltage Measurement... 19:16:04 Voltage Offset Correction: v_off_ini = -155.194 uV, v_off_fin = -159.945 uV 19:16:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.221 uVs 19:16:04 Integrated Voltage Measurement... 19:16:13 Voltage Offset Correction: v_off_ini = -144.605 uV, v_off_fin = -143.499 uV 19:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.864 uVs 19:16:13 Integrated Voltage Measurement... 19:16:22 Voltage Offset Correction: v_off_ini = -151.629 uV, v_off_fin = -150.476 uV 19:16:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.305 uVs 19:16:22 Integrated Voltage Measurement... 19:16:31 Voltage Offset Correction: v_off_ini = -158.218 uV, v_off_fin = -140.613 uV 19:16:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.464 uVs 19:16:31 Integrated Voltage Measurement... 19:16:40 Voltage Offset Correction: v_off_ini = -145.572 uV, v_off_fin = -164.316 uV 19:16:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -124.582 uVs 19:16:40 Integrated Voltage Measurement... 19:16:49 Voltage Offset Correction: v_off_ini = -143.055 uV, v_off_fin = -138.333 uV 19:16:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.180 uVs 19:16:51 I2X Average and RMS of Measurements VT = -127.436 +- 7.990 uVs I2X = 11.725 +- 0.736 uTm^2 19:16:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:16:59 Integrated Voltage Measurement... 19:17:08 Voltage Offset Correction: v_off_ini = -154.126 uV, v_off_fin = -151.152 uV 19:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.981 uVs 19:17:08 Integrated Voltage Measurement... 19:17:17 Voltage Offset Correction: v_off_ini = -153.079 uV, v_off_fin = -154.050 uV 19:17:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.397 uVs 19:17:17 Integrated Voltage Measurement... 19:17:26 Voltage Offset Correction: v_off_ini = -148.647 uV, v_off_fin = -160.225 uV 19:17:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.718 uVs 19:17:26 Integrated Voltage Measurement... 19:17:35 Voltage Offset Correction: v_off_ini = -158.271 uV, v_off_fin = -161.867 uV 19:17:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.592 uVs 19:17:35 Integrated Voltage Measurement... 19:17:44 Voltage Offset Correction: v_off_ini = -160.947 uV, v_off_fin = -166.125 uV 19:17:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.667 uVs 19:17:44 Integrated Voltage Measurement... 19:17:53 Voltage Offset Correction: v_off_ini = -163.494 uV, v_off_fin = -167.710 uV 19:17:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.810 uVs 19:17:55 I2Y Average and RMS of Measurements VT = -289.027 +- 3.505 uVs I2Y = -26.591 +- 0.322 uTm^2 19:18:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:18:07 Integrated Voltage Measurement... 19:18:16 Voltage Offset Correction: v_off_ini = -161.039 uV, v_off_fin = -166.741 uV 19:18:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -132.155 uVs 19:18:17 Integrated Voltage Measurement... 19:18:25 Voltage Offset Correction: v_off_ini = -163.143 uV, v_off_fin = -171.328 uV 19:18:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 132.584 uVs 19:18:26 Integrated Voltage Measurement... 19:18:34 Voltage Offset Correction: v_off_ini = -165.429 uV, v_off_fin = -159.915 uV 19:18:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.869 uVs 19:18:35 Integrated Voltage Measurement... 19:18:43 Voltage Offset Correction: v_off_ini = -170.133 uV, v_off_fin = -159.880 uV 19:18:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 145.994 uVs 19:18:44 Integrated Voltage Measurement... 19:18:53 Voltage Offset Correction: v_off_ini = -169.825 uV, v_off_fin = -167.054 uV 19:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.399 uVs 19:18:53 Integrated Voltage Measurement... 19:19:02 Voltage Offset Correction: v_off_ini = -168.651 uV, v_off_fin = -160.496 uV 19:19:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.384 uVs 19:19:06 I1X Average and RMS of Measurements VT = -142.731 +- 7.601 uVs I1X = 28.549 +- 1.519 uTm 19:19:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:19:13 Integrated Voltage Measurement... 19:19:22 Voltage Offset Correction: v_off_ini = -155.633 uV, v_off_fin = -178.619 uV 19:19:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.347 uVs 19:19:22 Integrated Voltage Measurement... 19:19:31 Voltage Offset Correction: v_off_ini = -164.137 uV, v_off_fin = -149.916 uV 19:19:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.922 uVs 19:19:31 Integrated Voltage Measurement... 19:19:40 Voltage Offset Correction: v_off_ini = -159.326 uV, v_off_fin = -170.825 uV 19:19:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.107 uVs 19:19:40 Integrated Voltage Measurement... 19:19:49 Voltage Offset Correction: v_off_ini = -150.831 uV, v_off_fin = -144.060 uV 19:19:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.827 uVs 19:19:49 Integrated Voltage Measurement... 19:19:58 Voltage Offset Correction: v_off_ini = -161.011 uV, v_off_fin = -170.369 uV 19:19:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.649 uVs 19:19:58 Integrated Voltage Measurement... 19:20:06 Voltage Offset Correction: v_off_ini = -153.258 uV, v_off_fin = -139.030 uV 19:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.545 uVs 19:20:11 I1Y Average and RMS of Measurements VT = -211.066 +- 4.316 uVs I1Y = -42.214 +- 0.863 uTm 19:20:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:20:16 Integrated Voltage Measurement... 19:20:25 Voltage Offset Correction: v_off_ini = -174.528 uV, v_off_fin = -178.462 uV 19:20:25 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -128.851 uVs 19:20:25 Integrated Voltage Measurement... 19:20:34 Voltage Offset Correction: v_off_ini = -168.852 uV, v_off_fin = -154.683 uV 19:20:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.687 uVs 19:20:34 Integrated Voltage Measurement... 19:20:43 Voltage Offset Correction: v_off_ini = -162.966 uV, v_off_fin = -166.197 uV 19:20:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.568 uVs 19:20:43 Integrated Voltage Measurement... 19:20:52 Voltage Offset Correction: v_off_ini = -157.478 uV, v_off_fin = -141.219 uV 19:20:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.246 uVs 19:20:52 Integrated Voltage Measurement... 19:21:01 Voltage Offset Correction: v_off_ini = -151.175 uV, v_off_fin = -166.580 uV 19:21:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -142.302 uVs 19:21:01 Integrated Voltage Measurement... 19:21:10 Voltage Offset Correction: v_off_ini = -170.005 uV, v_off_fin = -156.094 uV 19:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.002 uVs 19:21:12 I2X Average and RMS of Measurements VT = -131.609 +- 8.216 uVs I2X = 12.108 +- 0.757 uTm^2 19:21:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:21:17 Integrated Voltage Measurement... 19:21:26 Voltage Offset Correction: v_off_ini = -154.809 uV, v_off_fin = -149.584 uV 19:21:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.952 uVs 19:21:27 Integrated Voltage Measurement... 19:21:35 Voltage Offset Correction: v_off_ini = -156.231 uV, v_off_fin = -155.529 uV 19:21:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.423 uVs 19:21:36 Integrated Voltage Measurement... 19:21:45 Voltage Offset Correction: v_off_ini = -159.754 uV, v_off_fin = -170.300 uV 19:21:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.126 uVs 19:21:45 Integrated Voltage Measurement... 19:21:54 Voltage Offset Correction: v_off_ini = -162.071 uV, v_off_fin = -162.228 uV 19:21:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.900 uVs 19:21:54 Integrated Voltage Measurement... 19:22:03 Voltage Offset Correction: v_off_ini = -160.809 uV, v_off_fin = -165.818 uV 19:22:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.842 uVs 19:22:03 Integrated Voltage Measurement... 19:22:12 Voltage Offset Correction: v_off_ini = -174.650 uV, v_off_fin = -166.768 uV 19:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.821 uVs 19:22:14 I2Y Average and RMS of Measurements VT = -245.177 +- 8.110 uVs I2Y = -22.556 +- 0.746 uTm^2 19:22:18 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:22:22 Integrated Voltage Measurement... 19:22:31 Voltage Offset Correction: v_off_ini = -159.671 uV, v_off_fin = -175.486 uV 19:22:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.885 uVs 19:22:31 Integrated Voltage Measurement... 19:22:40 Voltage Offset Correction: v_off_ini = -162.734 uV, v_off_fin = -158.592 uV 19:22:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.738 uVs 19:22:41 Integrated Voltage Measurement... 19:22:49 Voltage Offset Correction: v_off_ini = -160.376 uV, v_off_fin = -164.899 uV 19:22:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.142 uVs 19:22:50 Integrated Voltage Measurement... 19:22:58 Voltage Offset Correction: v_off_ini = -164.398 uV, v_off_fin = -159.993 uV 19:22:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 127.866 uVs 19:22:59 Integrated Voltage Measurement... 19:23:08 Voltage Offset Correction: v_off_ini = -167.638 uV, v_off_fin = -163.566 uV 19:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -149.889 uVs 19:23:08 Integrated Voltage Measurement... 19:23:17 Voltage Offset Correction: v_off_ini = -153.464 uV, v_off_fin = -155.070 uV 19:23:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.645 uVs 19:23:21 I1X Average and RMS of Measurements VT = -145.528 +- 2.807 uVs I1X = 29.107 +- 0.561 uTm 19:23:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:23:28 Integrated Voltage Measurement... 19:23:36 Voltage Offset Correction: v_off_ini = -147.762 uV, v_off_fin = -153.562 uV 19:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.546 uVs 19:23:37 Integrated Voltage Measurement... 19:23:45 Voltage Offset Correction: v_off_ini = -146.821 uV, v_off_fin = -132.855 uV 19:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.097 uVs 19:23:46 Integrated Voltage Measurement... 19:23:54 Voltage Offset Correction: v_off_ini = -141.158 uV, v_off_fin = -151.580 uV 19:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.628 uVs 19:23:55 Integrated Voltage Measurement... 19:24:03 Voltage Offset Correction: v_off_ini = -134.160 uV, v_off_fin = -120.644 uV 19:24:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.397 uVs 19:24:04 Integrated Voltage Measurement... 19:24:13 Voltage Offset Correction: v_off_ini = -134.854 uV, v_off_fin = -148.870 uV 19:24:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.990 uVs 19:24:13 Integrated Voltage Measurement... 19:24:21 Voltage Offset Correction: v_off_ini = -142.175 uV, v_off_fin = -121.273 uV 19:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.449 uVs 19:24:26 I1Y Average and RMS of Measurements VT = -211.851 +- 4.524 uVs I1Y = -42.370 +- 0.905 uTm 19:24:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:24:31 Integrated Voltage Measurement... 19:24:40 Voltage Offset Correction: v_off_ini = -132.493 uV, v_off_fin = -126.565 uV 19:24:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.954 uVs 19:24:40 Integrated Voltage Measurement... 19:24:49 Voltage Offset Correction: v_off_ini = -131.821 uV, v_off_fin = -121.295 uV 19:24:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.972 uVs 19:24:49 Integrated Voltage Measurement... 19:24:58 Voltage Offset Correction: v_off_ini = -129.778 uV, v_off_fin = -139.856 uV 19:24:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.353 uVs 19:24:58 Integrated Voltage Measurement... 19:25:07 Voltage Offset Correction: v_off_ini = -123.012 uV, v_off_fin = -111.144 uV 19:25:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.917 uVs 19:25:07 Integrated Voltage Measurement... 19:25:16 Voltage Offset Correction: v_off_ini = -116.794 uV, v_off_fin = -130.176 uV 19:25:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.881 uVs 19:25:16 Integrated Voltage Measurement... 19:25:25 Voltage Offset Correction: v_off_ini = -149.108 uV, v_off_fin = -128.913 uV 19:25:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.209 uVs 19:25:27 I2X Average and RMS of Measurements VT = -134.548 +- 5.114 uVs I2X = 12.379 +- 0.470 uTm^2 19:25:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:25:33 Integrated Voltage Measurement... 19:25:42 Voltage Offset Correction: v_off_ini = -136.876 uV, v_off_fin = -140.649 uV 19:25:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.856 uVs 19:25:42 Integrated Voltage Measurement... 19:25:51 Voltage Offset Correction: v_off_ini = -139.376 uV, v_off_fin = -137.386 uV 19:25:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.315 uVs 19:25:51 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = -148.659 uV, v_off_fin = -149.471 uV 19:26:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.195 uVs 19:26:00 Integrated Voltage Measurement... 19:26:09 Voltage Offset Correction: v_off_ini = -149.976 uV, v_off_fin = -148.606 uV 19:26:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.384 uVs 19:26:09 Integrated Voltage Measurement... 19:26:18 Voltage Offset Correction: v_off_ini = -157.995 uV, v_off_fin = -145.948 uV 19:26:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.565 uVs 19:26:18 Integrated Voltage Measurement... 19:26:27 Voltage Offset Correction: v_off_ini = -148.458 uV, v_off_fin = -136.592 uV 19:26:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.846 uVs 19:26:29 I2Y Average and RMS of Measurements VT = -249.527 +- 3.629 uVs I2Y = -22.956 +- 0.334 uTm^2 19:26:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:26:38 Integrated Voltage Measurement... 19:26:46 Voltage Offset Correction: v_off_ini = -146.148 uV, v_off_fin = -160.527 uV 19:26:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.483 uVs 19:26:47 Integrated Voltage Measurement... 19:26:56 Voltage Offset Correction: v_off_ini = -153.761 uV, v_off_fin = -141.153 uV 19:26:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.545 uVs 19:26:56 Integrated Voltage Measurement... 19:27:05 Voltage Offset Correction: v_off_ini = -135.957 uV, v_off_fin = -142.379 uV 19:27:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.761 uVs 19:27:05 Integrated Voltage Measurement... 19:27:14 Voltage Offset Correction: v_off_ini = -131.917 uV, v_off_fin = -149.304 uV 19:27:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.023 uVs 19:27:14 Integrated Voltage Measurement... 19:27:23 Voltage Offset Correction: v_off_ini = -142.878 uV, v_off_fin = -142.568 uV 19:27:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.584 uVs 19:27:23 Integrated Voltage Measurement... 19:27:32 Voltage Offset Correction: v_off_ini = -136.049 uV, v_off_fin = -140.223 uV 19:27:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.836 uVs 19:27:36 I1X Average and RMS of Measurements VT = -135.872 +- 7.285 uVs I1X = 27.175 +- 1.456 uTm 19:27:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:27:43 Integrated Voltage Measurement... 19:27:52 Voltage Offset Correction: v_off_ini = -139.282 uV, v_off_fin = -155.560 uV 19:27:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.695 uVs 19:27:52 Integrated Voltage Measurement... 19:28:01 Voltage Offset Correction: v_off_ini = -139.646 uV, v_off_fin = -136.226 uV 19:28:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.513 uVs 19:28:01 Integrated Voltage Measurement... 19:28:10 Voltage Offset Correction: v_off_ini = -152.647 uV, v_off_fin = -155.971 uV 19:28:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.032 uVs 19:28:10 Integrated Voltage Measurement... 19:28:19 Voltage Offset Correction: v_off_ini = -151.225 uV, v_off_fin = -152.888 uV 19:28:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.126 uVs 19:28:19 Integrated Voltage Measurement... 19:28:28 Voltage Offset Correction: v_off_ini = -152.329 uV, v_off_fin = -160.861 uV 19:28:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.677 uVs 19:28:28 Integrated Voltage Measurement... 19:28:37 Voltage Offset Correction: v_off_ini = -151.392 uV, v_off_fin = -142.263 uV 19:28:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.308 uVs 19:28:41 I1Y Average and RMS of Measurements VT = -206.059 +- 5.755 uVs I1Y = -41.212 +- 1.151 uTm 19:28:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:28:46 Integrated Voltage Measurement... 19:28:55 Voltage Offset Correction: v_off_ini = -143.939 uV, v_off_fin = -156.124 uV 19:28:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -106.878 uVs 19:28:55 Integrated Voltage Measurement... 19:29:04 Voltage Offset Correction: v_off_ini = -148.035 uV, v_off_fin = -144.754 uV 19:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.894 uVs 19:29:04 Integrated Voltage Measurement... 19:29:13 Voltage Offset Correction: v_off_ini = -161.310 uV, v_off_fin = -161.417 uV 19:29:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.218 uVs 19:29:13 Integrated Voltage Measurement... 19:29:22 Voltage Offset Correction: v_off_ini = -153.975 uV, v_off_fin = -133.590 uV 19:29:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 124.056 uVs 19:29:22 Integrated Voltage Measurement... 19:29:31 Voltage Offset Correction: v_off_ini = -153.016 uV, v_off_fin = -166.480 uV 19:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.843 uVs 19:29:31 Integrated Voltage Measurement... 19:29:40 Voltage Offset Correction: v_off_ini = -160.489 uV, v_off_fin = -142.299 uV 19:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.091 uVs 19:29:43 I2X Average and RMS of Measurements VT = -121.497 +- 3.234 uVs I2X = 11.178 +- 0.298 uTm^2 19:29:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:29:48 Integrated Voltage Measurement... 19:29:57 Voltage Offset Correction: v_off_ini = -149.732 uV, v_off_fin = -155.202 uV 19:29:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.554 uVs 19:29:57 Integrated Voltage Measurement... 19:30:06 Voltage Offset Correction: v_off_ini = -158.925 uV, v_off_fin = -166.946 uV 19:30:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.696 uVs 19:30:06 Integrated Voltage Measurement... 19:30:15 Voltage Offset Correction: v_off_ini = -167.339 uV, v_off_fin = -179.496 uV 19:30:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.263 uVs 19:30:15 Integrated Voltage Measurement... 19:30:24 Voltage Offset Correction: v_off_ini = -163.186 uV, v_off_fin = -173.263 uV 19:30:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.190 uVs 19:30:24 Integrated Voltage Measurement... 19:30:33 Voltage Offset Correction: v_off_ini = -177.468 uV, v_off_fin = -176.389 uV 19:30:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.558 uVs 19:30:33 Integrated Voltage Measurement... 19:30:42 Voltage Offset Correction: v_off_ini = -172.946 uV, v_off_fin = -170.830 uV 19:30:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 246.221 uVs 19:30:44 I2Y Average and RMS of Measurements VT = -246.580 +- 4.790 uVs I2Y = -22.686 +- 0.440 uTm^2 19:30:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:30:53 Integrated Voltage Measurement... 19:31:02 Voltage Offset Correction: v_off_ini = -190.453 uV, v_off_fin = -181.135 uV 19:31:02 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4999 mm dXY = -0.4998 mm VT = -119.284 uVs 19:31:02 Integrated Voltage Measurement... 19:31:11 Voltage Offset Correction: v_off_ini = -179.394 uV, v_off_fin = -170.066 uV 19:31:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 118.873 uVs 19:31:11 Integrated Voltage Measurement... 19:31:20 Voltage Offset Correction: v_off_ini = -173.650 uV, v_off_fin = -177.427 uV 19:31:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.028 uVs 19:31:20 Integrated Voltage Measurement... 19:31:29 Voltage Offset Correction: v_off_ini = -164.302 uV, v_off_fin = -169.850 uV 19:31:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.188 uVs 19:31:29 Integrated Voltage Measurement... 19:31:38 Voltage Offset Correction: v_off_ini = -193.196 uV, v_off_fin = -183.080 uV 19:31:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.255 uVs 19:31:38 Integrated Voltage Measurement... 19:31:47 Voltage Offset Correction: v_off_ini = -187.618 uV, v_off_fin = -173.686 uV 19:31:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.824 uVs 19:31:51 I1X Average and RMS of Measurements VT = -122.075 +- 4.991 uVs I1X = 24.417 +- 0.998 uTm 19:31:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:31:58 Integrated Voltage Measurement... 19:32:07 Voltage Offset Correction: v_off_ini = -174.678 uV, v_off_fin = -180.817 uV 19:32:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.631 uVs 19:32:07 Integrated Voltage Measurement... 19:32:16 Voltage Offset Correction: v_off_ini = -182.941 uV, v_off_fin = -171.829 uV 19:32:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.374 uVs 19:32:16 Integrated Voltage Measurement... 19:32:25 Voltage Offset Correction: v_off_ini = -172.809 uV, v_off_fin = -187.959 uV 19:32:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.053 uVs 19:32:25 Integrated Voltage Measurement... 19:32:34 Voltage Offset Correction: v_off_ini = -164.589 uV, v_off_fin = -159.654 uV 19:32:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.173 uVs 19:32:34 Integrated Voltage Measurement... 19:32:43 Voltage Offset Correction: v_off_ini = -172.692 uV, v_off_fin = -169.820 uV 19:32:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.403 uVs 19:32:43 Integrated Voltage Measurement... 19:32:52 Voltage Offset Correction: v_off_ini = -183.937 uV, v_off_fin = -159.102 uV 19:32:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.484 uVs 19:32:56 I1Y Average and RMS of Measurements VT = -212.686 +- 3.853 uVs I1Y = -42.537 +- 0.771 uTm 19:32:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:33:01 Integrated Voltage Measurement... 19:33:10 Voltage Offset Correction: v_off_ini = -187.088 uV, v_off_fin = -177.282 uV 19:33:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -100.997 uVs 19:33:10 Integrated Voltage Measurement... 19:33:19 Voltage Offset Correction: v_off_ini = -165.936 uV, v_off_fin = -149.041 uV 19:33:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.947 uVs 19:33:19 Integrated Voltage Measurement... 19:33:28 Voltage Offset Correction: v_off_ini = -163.162 uV, v_off_fin = -168.222 uV 19:33:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.315 uVs 19:33:28 Integrated Voltage Measurement... 19:33:37 Voltage Offset Correction: v_off_ini = -155.570 uV, v_off_fin = -142.718 uV 19:33:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.211 uVs 19:33:37 Integrated Voltage Measurement... 19:33:46 Voltage Offset Correction: v_off_ini = -153.807 uV, v_off_fin = -158.949 uV 19:33:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.495 uVs 19:33:46 Integrated Voltage Measurement... 19:33:55 Voltage Offset Correction: v_off_ini = -154.699 uV, v_off_fin = -142.134 uV 19:33:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.669 uVs 19:33:58 I2X Average and RMS of Measurements VT = -119.272 +- 9.178 uVs I2X = 10.973 +- 0.844 uTm^2 19:34:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:34:03 Integrated Voltage Measurement... 19:34:12 Voltage Offset Correction: v_off_ini = -170.976 uV, v_off_fin = -160.238 uV 19:34:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.632 uVs 19:34:12 Integrated Voltage Measurement... 19:34:21 Voltage Offset Correction: v_off_ini = -161.463 uV, v_off_fin = -157.066 uV 19:34:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.047 uVs 19:34:21 Integrated Voltage Measurement... 19:34:30 Voltage Offset Correction: v_off_ini = -164.233 uV, v_off_fin = -140.911 uV 19:34:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.986 uVs 19:34:30 Integrated Voltage Measurement... 19:34:39 Voltage Offset Correction: v_off_ini = -149.721 uV, v_off_fin = -136.817 uV 19:34:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.457 uVs 19:34:39 Integrated Voltage Measurement... 19:34:48 Voltage Offset Correction: v_off_ini = -141.000 uV, v_off_fin = -146.040 uV 19:34:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.927 uVs 19:34:48 Integrated Voltage Measurement... 19:34:57 Voltage Offset Correction: v_off_ini = -137.260 uV, v_off_fin = -140.877 uV 19:34:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.376 uVs 19:34:59 I2Y Average and RMS of Measurements VT = -241.737 +- 0.443 uVs I2Y = -22.240 +- 0.041 uTm^2 19:35:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:35:08 Integrated Voltage Measurement... 19:35:17 Voltage Offset Correction: v_off_ini = -134.186 uV, v_off_fin = -140.234 uV 19:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.752 uVs 19:35:17 Integrated Voltage Measurement... 19:35:26 Voltage Offset Correction: v_off_ini = -131.274 uV, v_off_fin = -118.043 uV 19:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.394 uVs 19:35:26 Integrated Voltage Measurement... 19:35:35 Voltage Offset Correction: v_off_ini = -121.881 uV, v_off_fin = -125.709 uV 19:35:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.956 uVs 19:35:35 Integrated Voltage Measurement... 19:35:44 Voltage Offset Correction: v_off_ini = -131.320 uV, v_off_fin = -122.473 uV 19:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.895 uVs 19:35:44 Integrated Voltage Measurement... 19:35:53 Voltage Offset Correction: v_off_ini = -109.265 uV, v_off_fin = -117.922 uV 19:35:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.483 uVs 19:35:53 Integrated Voltage Measurement... 19:36:02 Voltage Offset Correction: v_off_ini = -111.882 uV, v_off_fin = -119.310 uV 19:36:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.161 uVs 19:36:06 I1X Average and RMS of Measurements VT = -113.940 +- 6.032 uVs I1X = 22.788 +- 1.206 uTm 19:36:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:36:13 Integrated Voltage Measurement... 19:36:22 Voltage Offset Correction: v_off_ini = -121.724 uV, v_off_fin = -146.808 uV 19:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.421 uVs 19:36:22 Integrated Voltage Measurement... 19:36:31 Voltage Offset Correction: v_off_ini = -134.980 uV, v_off_fin = -120.703 uV 19:36:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.870 uVs 19:36:31 Integrated Voltage Measurement... 19:36:40 Voltage Offset Correction: v_off_ini = -123.293 uV, v_off_fin = -135.094 uV 19:36:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.756 uVs 19:36:40 Integrated Voltage Measurement... 19:36:49 Voltage Offset Correction: v_off_ini = -135.195 uV, v_off_fin = -126.929 uV 19:36:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.423 uVs 19:36:49 Integrated Voltage Measurement... 19:36:58 Voltage Offset Correction: v_off_ini = -117.660 uV, v_off_fin = -139.190 uV 19:36:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.303 uVs 19:36:58 Integrated Voltage Measurement... 19:37:07 Voltage Offset Correction: v_off_ini = -122.652 uV, v_off_fin = -110.859 uV 19:37:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.853 uVs 19:37:11 I1Y Average and RMS of Measurements VT = -215.104 +- 1.470 uVs I1Y = -43.021 +- 0.294 uTm 19:37:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:37:16 Integrated Voltage Measurement... 19:37:25 Voltage Offset Correction: v_off_ini = -124.385 uV, v_off_fin = -143.517 uV 19:37:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.771 uVs 19:37:25 Integrated Voltage Measurement... 19:37:34 Voltage Offset Correction: v_off_ini = -120.871 uV, v_off_fin = -105.506 uV 19:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.938 uVs 19:37:34 Integrated Voltage Measurement... 19:37:43 Voltage Offset Correction: v_off_ini = -111.979 uV, v_off_fin = -125.848 uV 19:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.907 uVs 19:37:43 Integrated Voltage Measurement... 19:37:52 Voltage Offset Correction: v_off_ini = -133.369 uV, v_off_fin = -109.026 uV 19:37:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.419 uVs 19:37:52 Integrated Voltage Measurement... 19:38:01 Voltage Offset Correction: v_off_ini = -132.674 uV, v_off_fin = -134.436 uV 19:38:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.467 uVs 19:38:01 Integrated Voltage Measurement... 19:38:10 Voltage Offset Correction: v_off_ini = -129.894 uV, v_off_fin = -122.127 uV 19:38:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.243 uVs 19:38:13 I2X Average and RMS of Measurements VT = -97.791 +- 10.136 uVs I2X = 8.997 +- 0.933 uTm^2 19:38:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:38:18 Integrated Voltage Measurement... 19:38:27 Voltage Offset Correction: v_off_ini = -152.412 uV, v_off_fin = -136.700 uV 19:38:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.353 uVs 19:38:27 Integrated Voltage Measurement... 19:38:36 Voltage Offset Correction: v_off_ini = -144.998 uV, v_off_fin = -133.928 uV 19:38:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.910 uVs 19:38:36 Integrated Voltage Measurement... 19:38:45 Voltage Offset Correction: v_off_ini = -135.478 uV, v_off_fin = -133.695 uV 19:38:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.025 uVs 19:38:45 Integrated Voltage Measurement... 19:38:54 Voltage Offset Correction: v_off_ini = -134.768 uV, v_off_fin = -140.616 uV 19:38:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.444 uVs 19:38:54 Integrated Voltage Measurement... 19:39:03 Voltage Offset Correction: v_off_ini = -128.569 uV, v_off_fin = -134.090 uV 19:39:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.212 uVs 19:39:03 Integrated Voltage Measurement... 19:39:12 Voltage Offset Correction: v_off_ini = -136.076 uV, v_off_fin = -143.218 uV 19:39:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.479 uVs 19:39:15 I2Y Average and RMS of Measurements VT = -254.070 +- 3.922 uVs I2Y = -23.374 +- 0.361 uTm^2 19:39:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:39:36 Integrated Voltage Measurement... 19:39:45 Voltage Offset Correction: v_off_ini = -129.109 uV, v_off_fin = -147.661 uV 19:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.565 uVs 19:39:45 Integrated Voltage Measurement... 19:39:54 Voltage Offset Correction: v_off_ini = -140.774 uV, v_off_fin = -144.993 uV 19:39:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.931 uVs 19:39:54 Integrated Voltage Measurement... 19:40:03 Voltage Offset Correction: v_off_ini = -145.268 uV, v_off_fin = -157.986 uV 19:40:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.478 uVs 19:40:03 Integrated Voltage Measurement... 19:40:12 Voltage Offset Correction: v_off_ini = -145.426 uV, v_off_fin = -132.425 uV 19:40:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.720 uVs 19:40:12 Integrated Voltage Measurement... 19:40:21 Voltage Offset Correction: v_off_ini = -141.519 uV, v_off_fin = -146.035 uV 19:40:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.584 uVs 19:40:21 Integrated Voltage Measurement... 19:40:30 Voltage Offset Correction: v_off_ini = -140.782 uV, v_off_fin = -136.230 uV 19:40:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.410 uVs 19:40:34 I1X Average and RMS of Measurements VT = -146.282 +- 2.612 uVs I1X = 29.257 +- 0.522 uTm 19:40:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:40:41 Integrated Voltage Measurement... 19:40:50 Voltage Offset Correction: v_off_ini = -146.782 uV, v_off_fin = -146.458 uV 19:40:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.005 uVs 19:40:50 Integrated Voltage Measurement... 19:40:59 Voltage Offset Correction: v_off_ini = -139.452 uV, v_off_fin = -135.643 uV 19:40:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.501 uVs 19:40:59 Integrated Voltage Measurement... 19:41:08 Voltage Offset Correction: v_off_ini = -134.228 uV, v_off_fin = -143.660 uV 19:41:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.330 uVs 19:41:08 Integrated Voltage Measurement... 19:41:17 Voltage Offset Correction: v_off_ini = -136.210 uV, v_off_fin = -135.478 uV 19:41:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.565 uVs 19:41:17 Integrated Voltage Measurement... 19:41:26 Voltage Offset Correction: v_off_ini = -141.376 uV, v_off_fin = -139.018 uV 19:41:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.363 uVs 19:41:26 Integrated Voltage Measurement... 19:41:35 Voltage Offset Correction: v_off_ini = -129.740 uV, v_off_fin = -140.061 uV 19:41:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.597 uVs 19:41:39 I1Y Average and RMS of Measurements VT = -181.560 +- 4.189 uVs I1Y = -36.312 +- 0.838 uTm 19:41:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:41:47 Integrated Voltage Measurement... 19:41:56 Voltage Offset Correction: v_off_ini = -152.552 uV, v_off_fin = -150.828 uV 19:41:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.852 uVs 19:41:56 Integrated Voltage Measurement... 19:42:05 Voltage Offset Correction: v_off_ini = -140.598 uV, v_off_fin = -136.024 uV 19:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.769 uVs 19:42:05 Integrated Voltage Measurement... 19:42:14 Voltage Offset Correction: v_off_ini = -152.988 uV, v_off_fin = -160.231 uV 19:42:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.065 uVs 19:42:14 Integrated Voltage Measurement... 19:42:23 Voltage Offset Correction: v_off_ini = -156.633 uV, v_off_fin = -143.207 uV 19:42:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.110 uVs 19:42:23 Integrated Voltage Measurement... 19:42:32 Voltage Offset Correction: v_off_ini = -132.890 uV, v_off_fin = -147.395 uV 19:42:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.257 uVs 19:42:32 Integrated Voltage Measurement... 19:42:41 Voltage Offset Correction: v_off_ini = -139.940 uV, v_off_fin = -133.065 uV 19:42:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.182 uVs 19:42:44 I2X Average and RMS of Measurements VT = -120.872 +- 4.870 uVs I2X = 11.120 +- 0.448 uTm^2 19:42:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:42:51 Integrated Voltage Measurement... 19:43:00 Voltage Offset Correction: v_off_ini = -151.277 uV, v_off_fin = -147.524 uV 19:43:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.831 uVs 19:43:00 Integrated Voltage Measurement... 19:43:09 Voltage Offset Correction: v_off_ini = -153.910 uV, v_off_fin = -152.898 uV 19:43:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.422 uVs 19:43:09 Integrated Voltage Measurement... 19:43:18 Voltage Offset Correction: v_off_ini = -145.597 uV, v_off_fin = -152.274 uV 19:43:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.183 uVs 19:43:18 Integrated Voltage Measurement... 19:43:27 Voltage Offset Correction: v_off_ini = -160.082 uV, v_off_fin = -155.862 uV 19:43:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.646 uVs 19:43:27 Integrated Voltage Measurement... 19:43:36 Voltage Offset Correction: v_off_ini = -143.970 uV, v_off_fin = -162.283 uV 19:43:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.907 uVs 19:43:37 Integrated Voltage Measurement... 19:43:45 Voltage Offset Correction: v_off_ini = -151.908 uV, v_off_fin = -148.550 uV 19:43:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.309 uVs 19:43:48 I2Y Average and RMS of Measurements VT = -208.216 +- 5.481 uVs I2Y = -19.156 +- 0.504 uTm^2 19:43:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:43:57 Integrated Voltage Measurement... 19:44:06 Voltage Offset Correction: v_off_ini = -148.733 uV, v_off_fin = -162.285 uV 19:44:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.134 uVs 19:44:06 Integrated Voltage Measurement... 19:44:15 Voltage Offset Correction: v_off_ini = -166.365 uV, v_off_fin = -154.062 uV 19:44:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 131.337 uVs 19:44:15 Integrated Voltage Measurement... 19:44:24 Voltage Offset Correction: v_off_ini = -174.333 uV, v_off_fin = -173.386 uV 19:44:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.921 uVs 19:44:24 Integrated Voltage Measurement... 19:44:33 Voltage Offset Correction: v_off_ini = -157.685 uV, v_off_fin = -159.938 uV 19:44:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.436 uVs 19:44:33 Integrated Voltage Measurement... 19:44:42 Voltage Offset Correction: v_off_ini = -164.223 uV, v_off_fin = -164.802 uV 19:44:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.109 uVs 19:44:42 Integrated Voltage Measurement... 19:44:51 Voltage Offset Correction: v_off_ini = -171.585 uV, v_off_fin = -172.419 uV 19:44:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.876 uVs 19:44:55 I1X Average and RMS of Measurements VT = -140.969 +- 7.712 uVs I1X = 28.195 +- 1.544 uTm 19:44:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:45:02 Integrated Voltage Measurement... 19:45:11 Voltage Offset Correction: v_off_ini = -183.599 uV, v_off_fin = -185.459 uV 19:45:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.026 uVs 19:45:11 Integrated Voltage Measurement... 19:45:20 Voltage Offset Correction: v_off_ini = -177.534 uV, v_off_fin = -162.151 uV 19:45:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.037 uVs 19:45:20 Integrated Voltage Measurement... 19:45:29 Voltage Offset Correction: v_off_ini = -174.065 uV, v_off_fin = -187.188 uV 19:45:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.797 uVs 19:45:29 Integrated Voltage Measurement... 19:45:38 Voltage Offset Correction: v_off_ini = -181.173 uV, v_off_fin = -181.641 uV 19:45:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.798 uVs 19:45:38 Integrated Voltage Measurement... 19:45:47 Voltage Offset Correction: v_off_ini = -200.466 uV, v_off_fin = -193.418 uV 19:45:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.747 uVs 19:45:47 Integrated Voltage Measurement... 19:45:56 Voltage Offset Correction: v_off_ini = -193.059 uV, v_off_fin = -170.405 uV 19:45:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.793 uVs 19:46:00 I1Y Average and RMS of Measurements VT = -207.866 +- 3.379 uVs I1Y = -41.573 +- 0.676 uTm 19:46:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:46:08 Integrated Voltage Measurement... 19:46:17 Voltage Offset Correction: v_off_ini = -193.152 uV, v_off_fin = -198.127 uV 19:46:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -128.481 uVs 19:46:17 Integrated Voltage Measurement... 19:46:26 Voltage Offset Correction: v_off_ini = -187.212 uV, v_off_fin = -174.882 uV 19:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.845 uVs 19:46:26 Integrated Voltage Measurement... 19:46:35 Voltage Offset Correction: v_off_ini = -188.399 uV, v_off_fin = -201.952 uV 19:46:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.197 uVs 19:46:35 Integrated Voltage Measurement... 19:46:44 Voltage Offset Correction: v_off_ini = -172.304 uV, v_off_fin = -178.194 uV 19:46:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.030 uVs 19:46:44 Integrated Voltage Measurement... 19:46:53 Voltage Offset Correction: v_off_ini = -170.642 uV, v_off_fin = -188.174 uV 19:46:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.419 uVs 19:46:53 Integrated Voltage Measurement... 19:47:02 Voltage Offset Correction: v_off_ini = -180.602 uV, v_off_fin = -177.165 uV 19:47:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.279 uVs 19:47:04 I2X Average and RMS of Measurements VT = -131.042 +- 4.605 uVs I2X = 12.056 +- 0.424 uTm^2 19:47:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:47:12 Integrated Voltage Measurement... 19:47:21 Voltage Offset Correction: v_off_ini = -195.858 uV, v_off_fin = -189.172 uV 19:47:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.039 uVs 19:47:21 Integrated Voltage Measurement... 19:47:30 Voltage Offset Correction: v_off_ini = -198.257 uV, v_off_fin = -199.814 uV 19:47:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.887 uVs 19:47:30 Integrated Voltage Measurement... 19:47:39 Voltage Offset Correction: v_off_ini = -192.756 uV, v_off_fin = -192.017 uV 19:47:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.648 uVs 19:47:39 Integrated Voltage Measurement... 19:47:48 Voltage Offset Correction: v_off_ini = -186.015 uV, v_off_fin = -198.830 uV 19:47:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.052 uVs 19:47:48 Integrated Voltage Measurement... 19:47:57 Voltage Offset Correction: v_off_ini = -191.875 uV, v_off_fin = -195.160 uV 19:47:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.160 uVs 19:47:57 Integrated Voltage Measurement... 19:48:06 Voltage Offset Correction: v_off_ini = -197.690 uV, v_off_fin = -193.755 uV 19:48:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.841 uVs 19:48:09 I2Y Average and RMS of Measurements VT = -227.271 +- 8.342 uVs I2Y = -20.909 +- 0.767 uTm^2 19:48:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:48:18 Integrated Voltage Measurement... 19:48:27 Voltage Offset Correction: v_off_ini = -196.169 uV, v_off_fin = -212.092 uV 19:48:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.991 uVs 19:48:27 Integrated Voltage Measurement... 19:48:36 Voltage Offset Correction: v_off_ini = -193.127 uV, v_off_fin = -198.943 uV 19:48:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 138.491 uVs 19:48:36 Integrated Voltage Measurement... 19:48:45 Voltage Offset Correction: v_off_ini = -186.837 uV, v_off_fin = -197.567 uV 19:48:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.639 uVs 19:48:45 Integrated Voltage Measurement... 19:48:54 Voltage Offset Correction: v_off_ini = -180.768 uV, v_off_fin = -187.938 uV 19:48:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.845 uVs 19:48:54 Integrated Voltage Measurement... 19:49:03 Voltage Offset Correction: v_off_ini = -192.306 uV, v_off_fin = -190.452 uV 19:49:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.672 uVs 19:49:03 Integrated Voltage Measurement... 19:49:12 Voltage Offset Correction: v_off_ini = -200.975 uV, v_off_fin = -187.114 uV 19:49:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.935 uVs 19:49:16 I1X Average and RMS of Measurements VT = -144.429 +- 1.728 uVs I1X = 28.887 +- 0.345 uTm 19:49:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:49:23 Integrated Voltage Measurement... 19:49:32 Voltage Offset Correction: v_off_ini = -195.715 uV, v_off_fin = -198.732 uV 19:49:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.253 uVs 19:49:32 Integrated Voltage Measurement... 19:49:41 Voltage Offset Correction: v_off_ini = -185.113 uV, v_off_fin = -185.747 uV 19:49:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.460 uVs 19:49:41 Integrated Voltage Measurement... 19:49:50 Voltage Offset Correction: v_off_ini = -195.451 uV, v_off_fin = -199.619 uV 19:49:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.006 uVs 19:49:50 Integrated Voltage Measurement... 19:49:59 Voltage Offset Correction: v_off_ini = -191.493 uV, v_off_fin = -188.371 uV 19:49:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.344 uVs 19:49:59 Integrated Voltage Measurement... 19:50:08 Voltage Offset Correction: v_off_ini = -179.212 uV, v_off_fin = -190.657 uV 19:50:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.369 uVs 19:50:08 Integrated Voltage Measurement... 19:50:17 Voltage Offset Correction: v_off_ini = -194.992 uV, v_off_fin = -184.506 uV 19:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.927 uVs 19:50:21 I1Y Average and RMS of Measurements VT = -210.226 +- 6.069 uVs I1Y = -42.045 +- 1.214 uTm 19:50:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:50:29 Integrated Voltage Measurement... 19:50:38 Voltage Offset Correction: v_off_ini = -182.219 uV, v_off_fin = -180.385 uV 19:50:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -150.597 uVs 19:50:38 Integrated Voltage Measurement... 19:50:47 Voltage Offset Correction: v_off_ini = -172.131 uV, v_off_fin = -172.302 uV 19:50:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.020 uVs 19:50:47 Integrated Voltage Measurement... 19:50:56 Voltage Offset Correction: v_off_ini = -191.271 uV, v_off_fin = -210.172 uV 19:50:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.270 uVs 19:50:56 Integrated Voltage Measurement... 19:51:05 Voltage Offset Correction: v_off_ini = -207.792 uV, v_off_fin = -193.762 uV 19:51:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.989 uVs 19:51:05 Integrated Voltage Measurement... 19:51:14 Voltage Offset Correction: v_off_ini = -194.857 uV, v_off_fin = -201.551 uV 19:51:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.054 uVs 19:51:14 Integrated Voltage Measurement... 19:51:23 Voltage Offset Correction: v_off_ini = -191.426 uV, v_off_fin = -177.389 uV 19:51:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 137.062 uVs 19:51:25 I2X Average and RMS of Measurements VT = -136.332 +- 2.352 uVs I2X = 12.543 +- 0.216 uTm^2 19:51:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:51:33 Integrated Voltage Measurement... 19:51:42 Voltage Offset Correction: v_off_ini = -185.457 uV, v_off_fin = -188.121 uV 19:51:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.758 uVs 19:51:42 Integrated Voltage Measurement... 19:51:51 Voltage Offset Correction: v_off_ini = -181.246 uV, v_off_fin = -182.163 uV 19:51:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.000 uVs 19:51:51 Integrated Voltage Measurement... 19:52:00 Voltage Offset Correction: v_off_ini = -194.073 uV, v_off_fin = -187.611 uV 19:52:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.371 uVs 19:52:00 Integrated Voltage Measurement... 19:52:09 Voltage Offset Correction: v_off_ini = -192.138 uV, v_off_fin = -186.648 uV 19:52:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.344 uVs 19:52:09 Integrated Voltage Measurement... 19:52:18 Voltage Offset Correction: v_off_ini = -178.207 uV, v_off_fin = -193.162 uV 19:52:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.085 uVs 19:52:18 Integrated Voltage Measurement... 19:52:27 Voltage Offset Correction: v_off_ini = -190.622 uV, v_off_fin = -196.870 uV 19:52:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.338 uVs 19:52:30 I2Y Average and RMS of Measurements VT = -249.649 +- 4.098 uVs I2Y = -22.968 +- 0.377 uTm^2 19:52:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:52:39 Integrated Voltage Measurement... 19:52:48 Voltage Offset Correction: v_off_ini = -190.594 uV, v_off_fin = -197.621 uV 19:52:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.947 uVs 19:52:48 Integrated Voltage Measurement... 19:52:57 Voltage Offset Correction: v_off_ini = -204.292 uV, v_off_fin = -193.052 uV 19:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 150.528 uVs 19:52:57 Integrated Voltage Measurement... 19:53:06 Voltage Offset Correction: v_off_ini = -189.135 uV, v_off_fin = -193.725 uV 19:53:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.583 uVs 19:53:06 Integrated Voltage Measurement... 19:53:15 Voltage Offset Correction: v_off_ini = -186.332 uV, v_off_fin = -181.799 uV 19:53:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.493 uVs 19:53:15 Integrated Voltage Measurement... 19:53:24 Voltage Offset Correction: v_off_ini = -190.887 uV, v_off_fin = -211.030 uV 19:53:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.226 uVs 19:53:24 Integrated Voltage Measurement... 19:53:33 Voltage Offset Correction: v_off_ini = -199.133 uV, v_off_fin = -200.976 uV 19:53:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.079 uVs 19:53:37 I1X Average and RMS of Measurements VT = -149.142 +- 1.893 uVs I1X = 29.830 +- 0.380 uTm 19:53:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:53:44 Integrated Voltage Measurement... 19:53:53 Voltage Offset Correction: v_off_ini = -197.122 uV, v_off_fin = -209.716 uV 19:53:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.489 uVs 19:53:53 Integrated Voltage Measurement... 19:54:02 Voltage Offset Correction: v_off_ini = -209.663 uV, v_off_fin = -202.803 uV 19:54:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.668 uVs 19:54:02 Integrated Voltage Measurement... 19:54:11 Voltage Offset Correction: v_off_ini = -206.420 uV, v_off_fin = -222.897 uV 19:54:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.645 uVs 19:54:11 Integrated Voltage Measurement... 19:54:20 Voltage Offset Correction: v_off_ini = -219.090 uV, v_off_fin = -201.904 uV 19:54:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.387 uVs 19:54:20 Integrated Voltage Measurement... 19:54:29 Voltage Offset Correction: v_off_ini = -206.726 uV, v_off_fin = -203.808 uV 19:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.273 uVs 19:54:29 Integrated Voltage Measurement... 19:54:38 Voltage Offset Correction: v_off_ini = -213.240 uV, v_off_fin = -206.198 uV 19:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.127 uVs 19:54:42 I1Y Average and RMS of Measurements VT = -234.931 +- 3.857 uVs I1Y = -46.987 +- 0.772 uTm 19:54:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:54:50 Integrated Voltage Measurement... 19:54:59 Voltage Offset Correction: v_off_ini = -209.923 uV, v_off_fin = -229.000 uV 19:54:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -155.288 uVs 19:54:59 Integrated Voltage Measurement... 19:55:08 Voltage Offset Correction: v_off_ini = -203.641 uV, v_off_fin = -215.417 uV 19:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.885 uVs 19:55:08 Integrated Voltage Measurement... 19:55:17 Voltage Offset Correction: v_off_ini = -221.632 uV, v_off_fin = -245.600 uV 19:55:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.297 uVs 19:55:17 Integrated Voltage Measurement... 19:55:26 Voltage Offset Correction: v_off_ini = -226.480 uV, v_off_fin = -214.654 uV 19:55:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 137.363 uVs 19:55:26 Integrated Voltage Measurement... 19:55:35 Voltage Offset Correction: v_off_ini = -215.944 uV, v_off_fin = -235.281 uV 19:55:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.574 uVs 19:55:35 Integrated Voltage Measurement... 19:55:44 Voltage Offset Correction: v_off_ini = -223.064 uV, v_off_fin = -211.856 uV 19:55:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 124.725 uVs 19:55:46 I2X Average and RMS of Measurements VT = -132.355 +- 3.667 uVs I2X = 12.177 +- 0.337 uTm^2 19:55:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:55:54 Integrated Voltage Measurement... 19:56:03 Voltage Offset Correction: v_off_ini = -235.092 uV, v_off_fin = -218.093 uV 19:56:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.747 uVs 19:56:03 Integrated Voltage Measurement... 19:56:12 Voltage Offset Correction: v_off_ini = -217.823 uV, v_off_fin = -235.180 uV 19:56:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.894 uVs 19:56:12 Integrated Voltage Measurement... 19:56:21 Voltage Offset Correction: v_off_ini = -235.101 uV, v_off_fin = -229.704 uV 19:56:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.449 uVs 19:56:21 Integrated Voltage Measurement... 19:56:30 Voltage Offset Correction: v_off_ini = -217.757 uV, v_off_fin = -223.436 uV 19:56:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.749 uVs 19:56:30 Integrated Voltage Measurement... 19:56:39 Voltage Offset Correction: v_off_ini = -223.308 uV, v_off_fin = -238.025 uV 19:56:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.347 uVs 19:56:39 Integrated Voltage Measurement... 19:56:48 Voltage Offset Correction: v_off_ini = -224.573 uV, v_off_fin = -244.324 uV 19:56:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.108 uVs 19:56:51 I2Y Average and RMS of Measurements VT = -273.382 +- 7.275 uVs I2Y = -25.151 +- 0.669 uTm^2 19:56:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:57:00 Integrated Voltage Measurement... 19:57:09 Voltage Offset Correction: v_off_ini = -232.130 uV, v_off_fin = -224.875 uV 19:57:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.722 uVs 19:57:09 Integrated Voltage Measurement... 19:57:18 Voltage Offset Correction: v_off_ini = -224.454 uV, v_off_fin = -226.460 uV 19:57:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 165.431 uVs 19:57:18 Integrated Voltage Measurement... 19:57:27 Voltage Offset Correction: v_off_ini = -227.066 uV, v_off_fin = -228.736 uV 19:57:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.628 uVs 19:57:27 Integrated Voltage Measurement... 19:57:36 Voltage Offset Correction: v_off_ini = -217.089 uV, v_off_fin = -221.457 uV 19:57:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.362 uVs 19:57:36 Integrated Voltage Measurement... 19:57:45 Voltage Offset Correction: v_off_ini = -206.796 uV, v_off_fin = -215.870 uV 19:57:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.809 uVs 19:57:45 Integrated Voltage Measurement... 19:57:54 Voltage Offset Correction: v_off_ini = -214.570 uV, v_off_fin = -212.923 uV 19:57:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.477 uVs 19:57:58 I1X Average and RMS of Measurements VT = -149.571 +- 2.539 uVs I1X = 29.914 +- 0.508 uTm 19:58:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:58:05 Integrated Voltage Measurement... 19:58:14 Voltage Offset Correction: v_off_ini = -226.121 uV, v_off_fin = -234.778 uV 19:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.072 uVs 19:58:14 Integrated Voltage Measurement... 19:58:23 Voltage Offset Correction: v_off_ini = -218.085 uV, v_off_fin = -205.047 uV 19:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.449 uVs 19:58:23 Integrated Voltage Measurement... 19:58:32 Voltage Offset Correction: v_off_ini = -213.112 uV, v_off_fin = -213.837 uV 19:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.192 uVs 19:58:32 Integrated Voltage Measurement... 19:58:41 Voltage Offset Correction: v_off_ini = -212.908 uV, v_off_fin = -201.055 uV 19:58:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 243.717 uVs 19:58:41 Integrated Voltage Measurement... 19:58:50 Voltage Offset Correction: v_off_ini = -197.153 uV, v_off_fin = -200.436 uV 19:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.875 uVs 19:58:50 Integrated Voltage Measurement... 19:58:59 Voltage Offset Correction: v_off_ini = -201.485 uV, v_off_fin = -187.611 uV 19:58:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.499 uVs 19:59:03 I1Y Average and RMS of Measurements VT = -245.967 +- 1.313 uVs I1Y = -49.194 +- 0.264 uTm 19:59:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:59:11 Integrated Voltage Measurement... 19:59:20 Voltage Offset Correction: v_off_ini = -223.971 uV, v_off_fin = -232.095 uV 19:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.164 uVs 19:59:20 Integrated Voltage Measurement... 19:59:29 Voltage Offset Correction: v_off_ini = -219.053 uV, v_off_fin = -208.044 uV 19:59:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.112 uVs 19:59:29 Integrated Voltage Measurement... 19:59:38 Voltage Offset Correction: v_off_ini = -224.713 uV, v_off_fin = -237.224 uV 19:59:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.254 uVs 19:59:38 Integrated Voltage Measurement... 19:59:47 Voltage Offset Correction: v_off_ini = -218.151 uV, v_off_fin = -223.501 uV 19:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.581 uVs 19:59:47 Integrated Voltage Measurement... 19:59:56 Voltage Offset Correction: v_off_ini = -218.174 uV, v_off_fin = -225.119 uV 19:59:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.414 uVs 19:59:56 Integrated Voltage Measurement... 20:00:05 Voltage Offset Correction: v_off_ini = -219.810 uV, v_off_fin = -207.610 uV 20:00:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.157 uVs 20:00:07 I2X Average and RMS of Measurements VT = -136.114 +- 3.198 uVs I2X = 12.523 +- 0.294 uTm^2 20:00:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:00:15 Integrated Voltage Measurement... 20:00:24 Voltage Offset Correction: v_off_ini = -213.544 uV, v_off_fin = -210.529 uV 20:00:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.717 uVs 20:00:24 Integrated Voltage Measurement... 20:00:33 Voltage Offset Correction: v_off_ini = -201.220 uV, v_off_fin = -211.125 uV 20:00:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.940 uVs 20:00:33 Integrated Voltage Measurement... 20:00:42 Voltage Offset Correction: v_off_ini = -210.398 uV, v_off_fin = -203.696 uV 20:00:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.154 uVs 20:00:42 Integrated Voltage Measurement... 20:00:51 Voltage Offset Correction: v_off_ini = -197.185 uV, v_off_fin = -201.667 uV 20:00:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.831 uVs 20:00:51 Integrated Voltage Measurement... 20:01:00 Voltage Offset Correction: v_off_ini = -209.383 uV, v_off_fin = -222.985 uV 20:01:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -288.127 uVs 20:01:00 Integrated Voltage Measurement... 20:01:09 Voltage Offset Correction: v_off_ini = -209.028 uV, v_off_fin = -202.426 uV 20:01:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.521 uVs 20:01:12 I2Y Average and RMS of Measurements VT = -283.048 +- 3.697 uVs I2Y = -26.041 +- 0.340 uTm^2 20:01:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:01:24 Integrated Voltage Measurement... 20:01:33 Voltage Offset Correction: v_off_ini = -214.873 uV, v_off_fin = -228.119 uV 20:01:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.075 uVs 20:01:33 Integrated Voltage Measurement... 20:01:42 Voltage Offset Correction: v_off_ini = -209.093 uV, v_off_fin = -208.888 uV 20:01:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.689 uVs 20:01:42 Integrated Voltage Measurement... 20:01:51 Voltage Offset Correction: v_off_ini = -208.852 uV, v_off_fin = -216.420 uV 20:01:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.475 uVs 20:01:51 Integrated Voltage Measurement... 20:02:00 Voltage Offset Correction: v_off_ini = -211.659 uV, v_off_fin = -213.669 uV 20:02:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 145.492 uVs 20:02:00 Integrated Voltage Measurement... 20:02:09 Voltage Offset Correction: v_off_ini = -210.952 uV, v_off_fin = -212.700 uV 20:02:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -166.603 uVs 20:02:09 Integrated Voltage Measurement... 20:02:18 Voltage Offset Correction: v_off_ini = -221.570 uV, v_off_fin = -214.094 uV 20:02:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.585 uVs 20:02:22 I1X Average and RMS of Measurements VT = -145.987 +- 15.808 uVs I1X = 29.200 +- 3.164 uTm 20:02:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:02:29 Integrated Voltage Measurement... 20:02:38 Voltage Offset Correction: v_off_ini = -219.858 uV, v_off_fin = -221.106 uV 20:02:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.048 uVs 20:02:38 Integrated Voltage Measurement... 20:02:47 Voltage Offset Correction: v_off_ini = -222.466 uV, v_off_fin = -205.272 uV 20:02:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.007 uVs 20:02:47 Integrated Voltage Measurement... 20:02:56 Voltage Offset Correction: v_off_ini = -207.113 uV, v_off_fin = -222.544 uV 20:02:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.216 uVs 20:02:56 Integrated Voltage Measurement... 20:03:05 Voltage Offset Correction: v_off_ini = -215.343 uV, v_off_fin = -200.102 uV 20:03:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.690 uVs 20:03:05 Integrated Voltage Measurement... 20:03:14 Voltage Offset Correction: v_off_ini = -222.862 uV, v_off_fin = -218.745 uV 20:03:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.954 uVs 20:03:14 Integrated Voltage Measurement... 20:03:23 Voltage Offset Correction: v_off_ini = -211.732 uV, v_off_fin = -200.542 uV 20:03:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.562 uVs 20:03:27 I1Y Average and RMS of Measurements VT = -211.746 +- 2.850 uVs I1Y = -42.349 +- 0.570 uTm 20:03:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:03:32 Integrated Voltage Measurement... 20:03:41 Voltage Offset Correction: v_off_ini = -224.412 uV, v_off_fin = -211.023 uV 20:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.995 uVs 20:03:41 Integrated Voltage Measurement... 20:03:50 Voltage Offset Correction: v_off_ini = -206.221 uV, v_off_fin = -195.007 uV 20:03:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.285 uVs 20:03:50 Integrated Voltage Measurement... 20:03:59 Voltage Offset Correction: v_off_ini = -192.453 uV, v_off_fin = -216.206 uV 20:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -171.785 uVs 20:03:59 Integrated Voltage Measurement... 20:04:08 Voltage Offset Correction: v_off_ini = -216.949 uV, v_off_fin = -205.362 uV 20:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.702 uVs 20:04:08 Integrated Voltage Measurement... 20:04:17 Voltage Offset Correction: v_off_ini = -201.481 uV, v_off_fin = -224.805 uV 20:04:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.221 uVs 20:04:17 Integrated Voltage Measurement... 20:04:26 Voltage Offset Correction: v_off_ini = -207.246 uV, v_off_fin = -190.686 uV 20:04:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.145 uVs 20:04:29 I2X Average and RMS of Measurements VT = -148.022 +- 7.061 uVs I2X = 13.618 +- 0.650 uTm^2 20:04:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:04:34 Integrated Voltage Measurement... 20:04:43 Voltage Offset Correction: v_off_ini = -190.821 uV, v_off_fin = -201.982 uV 20:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.698 uVs 20:04:43 Integrated Voltage Measurement... 20:04:52 Voltage Offset Correction: v_off_ini = -199.885 uV, v_off_fin = -203.753 uV 20:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.533 uVs 20:04:52 Integrated Voltage Measurement... 20:05:01 Voltage Offset Correction: v_off_ini = -213.806 uV, v_off_fin = -219.081 uV 20:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.572 uVs 20:05:01 Integrated Voltage Measurement... 20:05:10 Voltage Offset Correction: v_off_ini = -227.119 uV, v_off_fin = -214.111 uV 20:05:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.565 uVs 20:05:10 Integrated Voltage Measurement... 20:05:19 Voltage Offset Correction: v_off_ini = -208.160 uV, v_off_fin = -207.594 uV 20:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.619 uVs 20:05:19 Integrated Voltage Measurement... 20:05:28 Voltage Offset Correction: v_off_ini = -220.720 uV, v_off_fin = -218.817 uV 20:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.604 uVs 20:05:31 I2Y Average and RMS of Measurements VT = -241.765 +- 9.791 uVs I2Y = -22.242 +- 0.901 uTm^2 20:05:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:05:39 Integrated Voltage Measurement... 20:05:48 Voltage Offset Correction: v_off_ini = -203.921 uV, v_off_fin = -217.925 uV 20:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.269 uVs 20:05:48 Integrated Voltage Measurement... 20:05:57 Voltage Offset Correction: v_off_ini = -210.378 uV, v_off_fin = -192.420 uV 20:05:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.443 uVs 20:05:57 Integrated Voltage Measurement... 20:06:06 Voltage Offset Correction: v_off_ini = -208.572 uV, v_off_fin = -204.119 uV 20:06:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.347 uVs 20:06:06 Integrated Voltage Measurement... 20:06:15 Voltage Offset Correction: v_off_ini = -195.900 uV, v_off_fin = -202.252 uV 20:06:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.111 uVs 20:06:15 Integrated Voltage Measurement... 20:06:24 Voltage Offset Correction: v_off_ini = -194.841 uV, v_off_fin = -203.741 uV 20:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.097 uVs 20:06:24 Integrated Voltage Measurement... 20:06:33 Voltage Offset Correction: v_off_ini = -204.238 uV, v_off_fin = -197.147 uV 20:06:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.937 uVs 20:06:37 I1X Average and RMS of Measurements VT = -150.367 +- 3.529 uVs I1X = 30.073 +- 0.706 uTm 20:06:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:06:44 Integrated Voltage Measurement... 20:06:53 Voltage Offset Correction: v_off_ini = -208.047 uV, v_off_fin = -212.552 uV 20:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.036 uVs 20:06:53 Integrated Voltage Measurement... 20:07:02 Voltage Offset Correction: v_off_ini = -209.508 uV, v_off_fin = -196.345 uV 20:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.994 uVs 20:07:02 Integrated Voltage Measurement... 20:07:11 Voltage Offset Correction: v_off_ini = -208.513 uV, v_off_fin = -205.992 uV 20:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.155 uVs 20:07:11 Integrated Voltage Measurement... 20:07:20 Voltage Offset Correction: v_off_ini = -213.596 uV, v_off_fin = -196.410 uV 20:07:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.611 uVs 20:07:20 Integrated Voltage Measurement... 20:07:29 Voltage Offset Correction: v_off_ini = -198.581 uV, v_off_fin = -208.124 uV 20:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.144 uVs 20:07:29 Integrated Voltage Measurement... 20:07:38 Voltage Offset Correction: v_off_ini = -192.457 uV, v_off_fin = -186.838 uV 20:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.822 uVs 20:07:42 I1Y Average and RMS of Measurements VT = -216.460 +- 5.024 uVs I1Y = -43.292 +- 1.005 uTm 20:07:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:07:47 Integrated Voltage Measurement... 20:07:56 Voltage Offset Correction: v_off_ini = -181.667 uV, v_off_fin = -190.399 uV 20:07:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.771 uVs 20:07:56 Integrated Voltage Measurement... 20:08:05 Voltage Offset Correction: v_off_ini = -179.871 uV, v_off_fin = -174.289 uV 20:08:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.276 uVs 20:08:05 Integrated Voltage Measurement... 20:08:14 Voltage Offset Correction: v_off_ini = -180.880 uV, v_off_fin = -191.004 uV 20:08:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.405 uVs 20:08:15 Integrated Voltage Measurement... 20:08:23 Voltage Offset Correction: v_off_ini = -173.525 uV, v_off_fin = -160.287 uV 20:08:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.536 uVs 20:08:24 Integrated Voltage Measurement... 20:08:33 Voltage Offset Correction: v_off_ini = -160.183 uV, v_off_fin = -162.365 uV 20:08:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.870 uVs 20:08:33 Integrated Voltage Measurement... 20:08:42 Voltage Offset Correction: v_off_ini = -178.405 uV, v_off_fin = -165.455 uV 20:08:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.877 uVs 20:08:44 I2X Average and RMS of Measurements VT = -140.956 +- 2.972 uVs I2X = 12.968 +- 0.273 uTm^2 20:08:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:08:49 Integrated Voltage Measurement... 20:08:58 Voltage Offset Correction: v_off_ini = -184.773 uV, v_off_fin = -177.961 uV 20:08:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.402 uVs 20:08:58 Integrated Voltage Measurement... 20:09:07 Voltage Offset Correction: v_off_ini = -174.418 uV, v_off_fin = -168.491 uV 20:09:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.002 uVs 20:09:07 Integrated Voltage Measurement... 20:09:16 Voltage Offset Correction: v_off_ini = -183.079 uV, v_off_fin = -168.066 uV 20:09:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.104 uVs 20:09:16 Integrated Voltage Measurement... 20:09:25 Voltage Offset Correction: v_off_ini = -183.129 uV, v_off_fin = -183.192 uV 20:09:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.993 uVs 20:09:25 Integrated Voltage Measurement... 20:09:34 Voltage Offset Correction: v_off_ini = -181.639 uV, v_off_fin = -184.147 uV 20:09:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.778 uVs 20:09:34 Integrated Voltage Measurement... 20:09:43 Voltage Offset Correction: v_off_ini = -179.223 uV, v_off_fin = -185.774 uV 20:09:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.029 uVs 20:09:46 I2Y Average and RMS of Measurements VT = -238.218 +- 4.339 uVs I2Y = -21.916 +- 0.399 uTm^2 20:09:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:09:54 Integrated Voltage Measurement... 20:10:03 Voltage Offset Correction: v_off_ini = -188.886 uV, v_off_fin = -207.387 uV 20:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.853 uVs 20:10:03 Integrated Voltage Measurement... 20:10:12 Voltage Offset Correction: v_off_ini = -176.029 uV, v_off_fin = -182.564 uV 20:10:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.821 uVs 20:10:12 Integrated Voltage Measurement... 20:10:21 Voltage Offset Correction: v_off_ini = -186.509 uV, v_off_fin = -191.263 uV 20:10:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.190 uVs 20:10:21 Integrated Voltage Measurement... 20:10:30 Voltage Offset Correction: v_off_ini = -183.440 uV, v_off_fin = -173.504 uV 20:10:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.276 uVs 20:10:30 Integrated Voltage Measurement... 20:10:39 Voltage Offset Correction: v_off_ini = -186.417 uV, v_off_fin = -189.718 uV 20:10:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.523 uVs 20:10:39 Integrated Voltage Measurement... 20:10:48 Voltage Offset Correction: v_off_ini = -183.416 uV, v_off_fin = -171.219 uV 20:10:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.010 uVs 20:10:52 I1X Average and RMS of Measurements VT = -141.946 +- 7.402 uVs I1X = 28.389 +- 1.480 uTm 20:10:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:10:59 Integrated Voltage Measurement... 20:11:08 Voltage Offset Correction: v_off_ini = -182.160 uV, v_off_fin = -200.725 uV 20:11:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.484 uVs 20:11:08 Integrated Voltage Measurement... 20:11:17 Voltage Offset Correction: v_off_ini = -179.977 uV, v_off_fin = -175.970 uV 20:11:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.287 uVs 20:11:17 Integrated Voltage Measurement... 20:11:26 Voltage Offset Correction: v_off_ini = -186.005 uV, v_off_fin = -197.170 uV 20:11:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.676 uVs 20:11:26 Integrated Voltage Measurement... 20:11:35 Voltage Offset Correction: v_off_ini = -177.292 uV, v_off_fin = -178.991 uV 20:11:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.582 uVs 20:11:35 Integrated Voltage Measurement... 20:11:44 Voltage Offset Correction: v_off_ini = -184.855 uV, v_off_fin = -197.209 uV 20:11:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.175 uVs 20:11:44 Integrated Voltage Measurement... 20:11:53 Voltage Offset Correction: v_off_ini = -187.163 uV, v_off_fin = -173.525 uV 20:11:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.653 uVs 20:11:57 I1Y Average and RMS of Measurements VT = -214.476 +- 3.430 uVs I1Y = -42.895 +- 0.686 uTm 20:12:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:12:03 Integrated Voltage Measurement... 20:12:12 Voltage Offset Correction: v_off_ini = -163.573 uV, v_off_fin = -178.072 uV 20:12:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.554 uVs 20:12:12 Integrated Voltage Measurement... 20:12:21 Voltage Offset Correction: v_off_ini = -170.665 uV, v_off_fin = -165.821 uV 20:12:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.779 uVs 20:12:21 Integrated Voltage Measurement... 20:12:30 Voltage Offset Correction: v_off_ini = -184.365 uV, v_off_fin = -190.872 uV 20:12:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.504 uVs 20:12:30 Integrated Voltage Measurement... 20:12:39 Voltage Offset Correction: v_off_ini = -169.118 uV, v_off_fin = -157.420 uV 20:12:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.374 uVs 20:12:39 Integrated Voltage Measurement... 20:12:48 Voltage Offset Correction: v_off_ini = -162.026 uV, v_off_fin = -159.947 uV 20:12:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.005 uVs 20:12:48 Integrated Voltage Measurement... 20:12:57 Voltage Offset Correction: v_off_ini = -164.719 uV, v_off_fin = -154.704 uV 20:12:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.230 uVs 20:12:59 I2X Average and RMS of Measurements VT = -130.241 +- 2.555 uVs I2X = 11.983 +- 0.235 uTm^2 20:13:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:13:04 Integrated Voltage Measurement... 20:13:13 Voltage Offset Correction: v_off_ini = -160.911 uV, v_off_fin = -159.761 uV 20:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.165 uVs 20:13:13 Integrated Voltage Measurement... 20:13:22 Voltage Offset Correction: v_off_ini = -157.764 uV, v_off_fin = -152.163 uV 20:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.456 uVs 20:13:22 Integrated Voltage Measurement... 20:13:31 Voltage Offset Correction: v_off_ini = -152.122 uV, v_off_fin = -161.215 uV 20:13:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.630 uVs 20:13:31 Integrated Voltage Measurement... 20:13:40 Voltage Offset Correction: v_off_ini = -146.243 uV, v_off_fin = -148.392 uV 20:13:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.094 uVs 20:13:40 Integrated Voltage Measurement... 20:13:49 Voltage Offset Correction: v_off_ini = -145.440 uV, v_off_fin = -143.345 uV 20:13:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.611 uVs 20:13:50 Integrated Voltage Measurement... 20:13:58 Voltage Offset Correction: v_off_ini = -136.345 uV, v_off_fin = -151.812 uV 20:13:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.920 uVs 20:14:01 I2Y Average and RMS of Measurements VT = -248.313 +- 3.122 uVs I2Y = -22.845 +- 0.287 uTm^2 20:14:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:14:09 Integrated Voltage Measurement... 20:14:18 Voltage Offset Correction: v_off_ini = -153.192 uV, v_off_fin = -154.339 uV 20:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.623 uVs 20:14:18 Integrated Voltage Measurement... 20:14:27 Voltage Offset Correction: v_off_ini = -148.556 uV, v_off_fin = -144.565 uV 20:14:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.046 uVs 20:14:27 Integrated Voltage Measurement... 20:14:36 Voltage Offset Correction: v_off_ini = -141.568 uV, v_off_fin = -146.746 uV 20:14:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.703 uVs 20:14:36 Integrated Voltage Measurement... 20:14:45 Voltage Offset Correction: v_off_ini = -139.118 uV, v_off_fin = -128.307 uV 20:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.493 uVs 20:14:45 Integrated Voltage Measurement... 20:14:54 Voltage Offset Correction: v_off_ini = -135.643 uV, v_off_fin = -135.631 uV 20:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.273 uVs 20:14:54 Integrated Voltage Measurement... 20:15:03 Voltage Offset Correction: v_off_ini = -136.471 uV, v_off_fin = -144.586 uV 20:15:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.884 uVs 20:15:08 I1X Average and RMS of Measurements VT = -129.837 +- 4.793 uVs I1X = 25.967 +- 0.959 uTm 20:15:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:15:14 Integrated Voltage Measurement... 20:15:23 Voltage Offset Correction: v_off_ini = -135.656 uV, v_off_fin = -144.714 uV 20:15:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -202.380 uVs 20:15:23 Integrated Voltage Measurement... 20:15:32 Voltage Offset Correction: v_off_ini = -133.358 uV, v_off_fin = -133.850 uV 20:15:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.561 uVs 20:15:32 Integrated Voltage Measurement... 20:15:41 Voltage Offset Correction: v_off_ini = -145.567 uV, v_off_fin = -143.832 uV 20:15:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.184 uVs 20:15:41 Integrated Voltage Measurement... 20:15:50 Voltage Offset Correction: v_off_ini = -131.832 uV, v_off_fin = -129.738 uV 20:15:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.792 uVs 20:15:50 Integrated Voltage Measurement... 20:15:59 Voltage Offset Correction: v_off_ini = -140.628 uV, v_off_fin = -155.039 uV 20:15:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.578 uVs 20:15:59 Integrated Voltage Measurement... 20:16:08 Voltage Offset Correction: v_off_ini = -138.994 uV, v_off_fin = -129.482 uV 20:16:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.588 uVs 20:16:13 I1Y Average and RMS of Measurements VT = -209.014 +- 3.035 uVs I1Y = -41.803 +- 0.608 uTm 20:16:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:16:18 Integrated Voltage Measurement... 20:16:27 Voltage Offset Correction: v_off_ini = -149.901 uV, v_off_fin = -152.126 uV 20:16:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -114.038 uVs 20:16:27 Integrated Voltage Measurement... 20:16:36 Voltage Offset Correction: v_off_ini = -146.060 uV, v_off_fin = -146.455 uV 20:16:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.079 uVs 20:16:36 Integrated Voltage Measurement... 20:16:45 Voltage Offset Correction: v_off_ini = -147.746 uV, v_off_fin = -151.352 uV 20:16:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.711 uVs 20:16:45 Integrated Voltage Measurement... 20:16:54 Voltage Offset Correction: v_off_ini = -150.872 uV, v_off_fin = -138.252 uV 20:16:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.612 uVs 20:16:54 Integrated Voltage Measurement... 20:17:03 Voltage Offset Correction: v_off_ini = -152.340 uV, v_off_fin = -150.958 uV 20:17:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.473 uVs 20:17:03 Integrated Voltage Measurement... 20:17:12 Voltage Offset Correction: v_off_ini = -141.536 uV, v_off_fin = -133.557 uV 20:17:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.641 uVs 20:17:14 I2X Average and RMS of Measurements VT = -109.926 +- 4.596 uVs I2X = 10.114 +- 0.423 uTm^2 20:17:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:17:19 Integrated Voltage Measurement... 20:17:28 Voltage Offset Correction: v_off_ini = -138.267 uV, v_off_fin = -136.236 uV 20:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.496 uVs 20:17:29 Integrated Voltage Measurement... 20:17:37 Voltage Offset Correction: v_off_ini = -141.636 uV, v_off_fin = -136.312 uV 20:17:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.670 uVs 20:17:38 Integrated Voltage Measurement... 20:17:47 Voltage Offset Correction: v_off_ini = -131.751 uV, v_off_fin = -144.129 uV 20:17:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.407 uVs 20:17:47 Integrated Voltage Measurement... 20:17:56 Voltage Offset Correction: v_off_ini = -132.467 uV, v_off_fin = -126.882 uV 20:17:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.698 uVs 20:17:56 Integrated Voltage Measurement... 20:18:05 Voltage Offset Correction: v_off_ini = -114.191 uV, v_off_fin = -123.687 uV 20:18:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.663 uVs 20:18:05 Integrated Voltage Measurement... 20:18:14 Voltage Offset Correction: v_off_ini = -143.568 uV, v_off_fin = -145.813 uV 20:18:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.429 uVs 20:18:16 I2Y Average and RMS of Measurements VT = -251.060 +- 10.596 uVs I2Y = -23.098 +- 0.975 uTm^2 20:18:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:18:24 Integrated Voltage Measurement... 20:18:33 Voltage Offset Correction: v_off_ini = -128.668 uV, v_off_fin = -136.435 uV 20:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.284 uVs 20:18:33 Integrated Voltage Measurement... 20:18:42 Voltage Offset Correction: v_off_ini = -145.937 uV, v_off_fin = -134.412 uV 20:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.815 uVs 20:18:43 Integrated Voltage Measurement... 20:18:51 Voltage Offset Correction: v_off_ini = -131.860 uV, v_off_fin = -138.161 uV 20:18:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.991 uVs 20:18:52 Integrated Voltage Measurement... 20:19:00 Voltage Offset Correction: v_off_ini = -150.423 uV, v_off_fin = -142.831 uV 20:19:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.503 uVs 20:19:01 Integrated Voltage Measurement... 20:19:10 Voltage Offset Correction: v_off_ini = -127.482 uV, v_off_fin = -136.114 uV 20:19:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.820 uVs 20:19:10 Integrated Voltage Measurement... 20:19:19 Voltage Offset Correction: v_off_ini = -126.569 uV, v_off_fin = -129.633 uV 20:19:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.234 uVs 20:19:23 I1X Average and RMS of Measurements VT = -123.775 +- 7.531 uVs I1X = 24.755 +- 1.506 uTm 20:19:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:19:30 Integrated Voltage Measurement... 20:19:39 Voltage Offset Correction: v_off_ini = -134.279 uV, v_off_fin = -140.894 uV 20:19:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.976 uVs 20:19:39 Integrated Voltage Measurement... 20:19:48 Voltage Offset Correction: v_off_ini = -129.013 uV, v_off_fin = -118.049 uV 20:19:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.406 uVs 20:19:48 Integrated Voltage Measurement... 20:19:57 Voltage Offset Correction: v_off_ini = -130.884 uV, v_off_fin = -156.447 uV 20:19:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.550 uVs 20:19:57 Integrated Voltage Measurement... 20:20:06 Voltage Offset Correction: v_off_ini = -140.128 uV, v_off_fin = -130.637 uV 20:20:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.542 uVs 20:20:06 Integrated Voltage Measurement... 20:20:15 Voltage Offset Correction: v_off_ini = -146.532 uV, v_off_fin = -151.788 uV 20:20:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.420 uVs 20:20:15 Integrated Voltage Measurement... 20:20:24 Voltage Offset Correction: v_off_ini = -148.683 uV, v_off_fin = -144.060 uV 20:20:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.753 uVs 20:20:28 I1Y Average and RMS of Measurements VT = -215.608 +- 4.253 uVs I1Y = -43.122 +- 0.851 uTm 20:20:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:20:33 Integrated Voltage Measurement... 20:20:42 Voltage Offset Correction: v_off_ini = -160.434 uV, v_off_fin = -175.864 uV 20:20:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.905 uVs 20:20:42 Integrated Voltage Measurement... 20:20:51 Voltage Offset Correction: v_off_ini = -165.371 uV, v_off_fin = -153.455 uV 20:20:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.266 uVs 20:20:51 Integrated Voltage Measurement... 20:21:00 Voltage Offset Correction: v_off_ini = -161.703 uV, v_off_fin = -164.831 uV 20:21:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.225 uVs 20:21:00 Integrated Voltage Measurement... 20:21:09 Voltage Offset Correction: v_off_ini = -160.924 uV, v_off_fin = -155.224 uV 20:21:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.682 uVs 20:21:09 Integrated Voltage Measurement... 20:21:18 Voltage Offset Correction: v_off_ini = -157.722 uV, v_off_fin = -174.260 uV 20:21:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.674 uVs 20:21:18 Integrated Voltage Measurement... 20:21:27 Voltage Offset Correction: v_off_ini = -161.958 uV, v_off_fin = -162.912 uV 20:21:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.267 uVs 20:21:30 I2X Average and RMS of Measurements VT = -109.837 +- 4.784 uVs I2X = 10.105 +- 0.440 uTm^2 20:21:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:21:35 Integrated Voltage Measurement... 20:21:44 Voltage Offset Correction: v_off_ini = -180.228 uV, v_off_fin = -168.186 uV 20:21:44 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -256.384 uVs 20:21:44 Integrated Voltage Measurement... 20:21:53 Voltage Offset Correction: v_off_ini = -164.362 uV, v_off_fin = -163.078 uV 20:21:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.464 uVs 20:21:53 Integrated Voltage Measurement... 20:22:02 Voltage Offset Correction: v_off_ini = -153.212 uV, v_off_fin = -166.405 uV 20:22:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.947 uVs 20:22:02 Integrated Voltage Measurement... 20:22:11 Voltage Offset Correction: v_off_ini = -155.174 uV, v_off_fin = -156.721 uV 20:22:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.364 uVs 20:22:11 Integrated Voltage Measurement... 20:22:20 Voltage Offset Correction: v_off_ini = -157.490 uV, v_off_fin = -147.082 uV 20:22:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.261 uVs 20:22:20 Integrated Voltage Measurement... 20:22:29 Voltage Offset Correction: v_off_ini = -150.214 uV, v_off_fin = -144.510 uV 20:22:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.330 uVs 20:22:31 I2Y Average and RMS of Measurements VT = -254.459 +- 5.543 uVs I2Y = -23.410 +- 0.509 uTm^2 20:23:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:23:07 Integrated Voltage Measurement... 20:23:16 Voltage Offset Correction: v_off_ini = -158.739 uV, v_off_fin = -161.739 uV 20:23:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.068 uVs 20:23:16 Integrated Voltage Measurement... 20:23:25 Voltage Offset Correction: v_off_ini = -148.717 uV, v_off_fin = -159.363 uV 20:23:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.945 uVs 20:23:25 Integrated Voltage Measurement... 20:23:34 Voltage Offset Correction: v_off_ini = -146.846 uV, v_off_fin = -152.026 uV 20:23:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.993 uVs 20:23:34 Integrated Voltage Measurement... 20:23:43 Voltage Offset Correction: v_off_ini = -163.426 uV, v_off_fin = -164.120 uV 20:23:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.067 uVs 20:23:43 Integrated Voltage Measurement... 20:23:52 Voltage Offset Correction: v_off_ini = -157.892 uV, v_off_fin = -167.173 uV 20:23:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.500 uVs 20:23:52 Integrated Voltage Measurement... 20:24:01 Voltage Offset Correction: v_off_ini = -158.964 uV, v_off_fin = -166.974 uV 20:24:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.014 uVs 20:24:05 I1X Average and RMS of Measurements VT = -101.931 +- 1.337 uVs I1X = 20.387 +- 0.268 uTm 20:24:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:24:12 Integrated Voltage Measurement... 20:24:21 Voltage Offset Correction: v_off_ini = -156.061 uV, v_off_fin = -165.809 uV 20:24:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.330 uVs 20:24:21 Integrated Voltage Measurement... 20:24:30 Voltage Offset Correction: v_off_ini = -154.824 uV, v_off_fin = -142.776 uV 20:24:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.614 uVs 20:24:30 Integrated Voltage Measurement... 20:24:39 Voltage Offset Correction: v_off_ini = -164.037 uV, v_off_fin = -162.728 uV 20:24:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.507 uVs 20:24:39 Integrated Voltage Measurement... 20:24:48 Voltage Offset Correction: v_off_ini = -159.088 uV, v_off_fin = -154.602 uV 20:24:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.996 uVs 20:24:48 Integrated Voltage Measurement... 20:24:57 Voltage Offset Correction: v_off_ini = -162.581 uV, v_off_fin = -173.169 uV 20:24:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.574 uVs 20:24:57 Integrated Voltage Measurement... 20:25:06 Voltage Offset Correction: v_off_ini = -150.617 uV, v_off_fin = -151.808 uV 20:25:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.391 uVs 20:25:10 I1Y Average and RMS of Measurements VT = -217.235 +- 2.670 uVs I1Y = -43.447 +- 0.534 uTm 20:25:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:25:18 Integrated Voltage Measurement... 20:25:27 Voltage Offset Correction: v_off_ini = -162.502 uV, v_off_fin = -158.676 uV 20:25:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -112.099 uVs 20:25:27 Integrated Voltage Measurement... 20:25:36 Voltage Offset Correction: v_off_ini = -150.352 uV, v_off_fin = -146.743 uV 20:25:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.691 uVs 20:25:36 Integrated Voltage Measurement... 20:25:45 Voltage Offset Correction: v_off_ini = -158.140 uV, v_off_fin = -164.345 uV 20:25:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.233 uVs 20:25:45 Integrated Voltage Measurement... 20:25:54 Voltage Offset Correction: v_off_ini = -166.498 uV, v_off_fin = -163.927 uV 20:25:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.407 uVs 20:25:54 Integrated Voltage Measurement... 20:26:03 Voltage Offset Correction: v_off_ini = -167.034 uV, v_off_fin = -171.530 uV 20:26:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.647 uVs 20:26:03 Integrated Voltage Measurement... 20:26:12 Voltage Offset Correction: v_off_ini = -176.075 uV, v_off_fin = -154.453 uV 20:26:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.359 uVs 20:26:14 I2X Average and RMS of Measurements VT = -106.239 +- 4.247 uVs I2X = 9.774 +- 0.391 uTm^2 20:26:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 20:26:22 Integrated Voltage Measurement... 20:26:31 Voltage Offset Correction: v_off_ini = -157.021 uV, v_off_fin = -161.786 uV 20:26:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.726 uVs 20:26:31 Integrated Voltage Measurement... 20:26:40 Voltage Offset Correction: v_off_ini = -160.307 uV, v_off_fin = -155.703 uV 20:26:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.677 uVs 20:26:40 Integrated Voltage Measurement... 20:26:49 Voltage Offset Correction: v_off_ini = -155.185 uV, v_off_fin = -152.694 uV 20:26:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.527 uVs 20:26:49 Integrated Voltage Measurement... 20:26:58 Voltage Offset Correction: v_off_ini = -158.615 uV, v_off_fin = -159.188 uV 20:26:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.054 uVs 20:26:58 Integrated Voltage Measurement... 20:27:07 Voltage Offset Correction: v_off_ini = -156.958 uV, v_off_fin = -183.221 uV 20:27:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.327 uVs 20:27:07 Integrated Voltage Measurement... 20:27:16 Voltage Offset Correction: v_off_ini = -179.471 uV, v_off_fin = -171.325 uV 20:27:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.684 uVs 20:27:19 I2Y Average and RMS of Measurements VT = -228.666 +- 4.140 uVs I2Y = -21.037 +- 0.381 uTm^2 20:27:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:27:28 Integrated Voltage Measurement... 20:27:36 Voltage Offset Correction: v_off_ini = -173.684 uV, v_off_fin = -171.925 uV 20:27:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.567 uVs 20:27:37 Integrated Voltage Measurement... 20:27:45 Voltage Offset Correction: v_off_ini = -167.751 uV, v_off_fin = -170.277 uV 20:27:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.839 uVs 20:27:46 Integrated Voltage Measurement... 20:27:54 Voltage Offset Correction: v_off_ini = -167.880 uV, v_off_fin = -163.256 uV 20:27:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.030 uVs 20:27:55 Integrated Voltage Measurement... 20:28:03 Voltage Offset Correction: v_off_ini = -157.874 uV, v_off_fin = -145.768 uV 20:28:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.103 uVs 20:28:04 Integrated Voltage Measurement... 20:28:12 Voltage Offset Correction: v_off_ini = -160.439 uV, v_off_fin = -163.593 uV 20:28:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.013 uVs 20:28:13 Integrated Voltage Measurement... 20:28:21 Voltage Offset Correction: v_off_ini = -153.075 uV, v_off_fin = -150.799 uV 20:28:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.408 uVs 20:28:26 I1X Average and RMS of Measurements VT = -113.160 +- 3.694 uVs I1X = 22.632 +- 0.739 uTm 20:28:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:28:32 Integrated Voltage Measurement... 20:28:41 Voltage Offset Correction: v_off_ini = -166.522 uV, v_off_fin = -166.237 uV 20:28:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.344 uVs 20:28:41 Integrated Voltage Measurement... 20:28:50 Voltage Offset Correction: v_off_ini = -146.600 uV, v_off_fin = -141.355 uV 20:28:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.024 uVs 20:28:50 Integrated Voltage Measurement... 20:28:59 Voltage Offset Correction: v_off_ini = -152.167 uV, v_off_fin = -156.423 uV 20:28:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.688 uVs 20:28:59 Integrated Voltage Measurement... 20:29:08 Voltage Offset Correction: v_off_ini = -143.500 uV, v_off_fin = -135.473 uV 20:29:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.113 uVs 20:29:08 Integrated Voltage Measurement... 20:29:17 Voltage Offset Correction: v_off_ini = -149.437 uV, v_off_fin = -149.502 uV 20:29:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.128 uVs 20:29:17 Integrated Voltage Measurement... 20:29:26 Voltage Offset Correction: v_off_ini = -141.860 uV, v_off_fin = -135.574 uV 20:29:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.629 uVs 20:29:31 I1Y Average and RMS of Measurements VT = -225.488 +- 2.978 uVs I1Y = -45.098 +- 0.596 uTm 20:29:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:29:38 Integrated Voltage Measurement... 20:29:47 Voltage Offset Correction: v_off_ini = -159.400 uV, v_off_fin = -163.413 uV 20:29:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.426 uVs 20:29:47 Integrated Voltage Measurement... 20:29:56 Voltage Offset Correction: v_off_ini = -154.010 uV, v_off_fin = -133.599 uV 20:29:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.600 uVs 20:29:56 Integrated Voltage Measurement... 20:30:05 Voltage Offset Correction: v_off_ini = -144.099 uV, v_off_fin = -161.339 uV 20:30:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.453 uVs 20:30:05 Integrated Voltage Measurement... 20:30:14 Voltage Offset Correction: v_off_ini = -150.734 uV, v_off_fin = -147.655 uV 20:30:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.637 uVs 20:30:14 Integrated Voltage Measurement... 20:30:23 Voltage Offset Correction: v_off_ini = -144.734 uV, v_off_fin = -162.941 uV 20:30:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.666 uVs 20:30:23 Integrated Voltage Measurement... 20:30:32 Voltage Offset Correction: v_off_ini = -164.082 uV, v_off_fin = -147.991 uV 20:30:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.432 uVs 20:30:35 I2X Average and RMS of Measurements VT = -102.536 +- 5.417 uVs I2X = 9.433 +- 0.498 uTm^2 20:30:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 20:30:42 Integrated Voltage Measurement... 20:30:51 Voltage Offset Correction: v_off_ini = -151.112 uV, v_off_fin = -157.380 uV 20:30:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.204 uVs 20:30:52 Integrated Voltage Measurement... 20:31:00 Voltage Offset Correction: v_off_ini = -150.791 uV, v_off_fin = -148.071 uV 20:31:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 232.999 uVs 20:31:01 Integrated Voltage Measurement... 20:31:10 Voltage Offset Correction: v_off_ini = -154.620 uV, v_off_fin = -166.076 uV 20:31:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.390 uVs 20:31:10 Integrated Voltage Measurement... 20:31:19 Voltage Offset Correction: v_off_ini = -148.172 uV, v_off_fin = -161.600 uV 20:31:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.019 uVs 20:31:19 Integrated Voltage Measurement... 20:31:28 Voltage Offset Correction: v_off_ini = -175.498 uV, v_off_fin = -155.650 uV 20:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.436 uVs 20:31:28 Integrated Voltage Measurement... 20:31:37 Voltage Offset Correction: v_off_ini = -156.513 uV, v_off_fin = -157.856 uV 20:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.455 uVs 20:31:39 I2Y Average and RMS of Measurements VT = -239.584 +- 2.404 uVs I2Y = -22.042 +- 0.221 uTm^2 20:31:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:31:48 Integrated Voltage Measurement... 20:31:57 Voltage Offset Correction: v_off_ini = -162.261 uV, v_off_fin = -166.775 uV 20:31:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.261 uVs 20:31:57 Integrated Voltage Measurement... 20:32:06 Voltage Offset Correction: v_off_ini = -167.575 uV, v_off_fin = -163.744 uV 20:32:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.897 uVs 20:32:06 Integrated Voltage Measurement... 20:32:15 Voltage Offset Correction: v_off_ini = -159.507 uV, v_off_fin = -161.562 uV 20:32:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.323 uVs 20:32:15 Integrated Voltage Measurement... 20:32:24 Voltage Offset Correction: v_off_ini = -165.086 uV, v_off_fin = -165.890 uV 20:32:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.897 uVs 20:32:24 Integrated Voltage Measurement... 20:32:33 Voltage Offset Correction: v_off_ini = -163.412 uV, v_off_fin = -167.302 uV 20:32:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.311 uVs 20:32:33 Integrated Voltage Measurement... 20:32:42 Voltage Offset Correction: v_off_ini = -168.997 uV, v_off_fin = -154.645 uV 20:32:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.253 uVs 20:32:46 I1X Average and RMS of Measurements VT = -111.990 +- 2.224 uVs I1X = 22.398 +- 0.445 uTm 20:32:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:32:53 Integrated Voltage Measurement... 20:33:02 Voltage Offset Correction: v_off_ini = -167.844 uV, v_off_fin = -170.880 uV 20:33:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.985 uVs 20:33:02 Integrated Voltage Measurement... 20:33:11 Voltage Offset Correction: v_off_ini = -162.736 uV, v_off_fin = -152.941 uV 20:33:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.671 uVs 20:33:11 Integrated Voltage Measurement... 20:33:20 Voltage Offset Correction: v_off_ini = -164.711 uV, v_off_fin = -189.358 uV 20:33:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.485 uVs 20:33:20 Integrated Voltage Measurement... 20:33:29 Voltage Offset Correction: v_off_ini = -176.096 uV, v_off_fin = -160.186 uV 20:33:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.926 uVs 20:33:29 Integrated Voltage Measurement... 20:33:38 Voltage Offset Correction: v_off_ini = -175.983 uV, v_off_fin = -173.321 uV 20:33:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.720 uVs 20:33:38 Integrated Voltage Measurement... 20:33:47 Voltage Offset Correction: v_off_ini = -167.337 uV, v_off_fin = -168.063 uV 20:33:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.253 uVs 20:33:51 I1Y Average and RMS of Measurements VT = -222.007 +- 1.048 uVs I1Y = -44.402 +- 0.211 uTm 20:33:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:33:59 Integrated Voltage Measurement... 20:34:08 Voltage Offset Correction: v_off_ini = -174.527 uV, v_off_fin = -177.206 uV 20:34:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.192 uVs 20:34:08 Integrated Voltage Measurement... 20:34:17 Voltage Offset Correction: v_off_ini = -168.335 uV, v_off_fin = -160.479 uV 20:34:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.429 uVs 20:34:17 Integrated Voltage Measurement... 20:34:26 Voltage Offset Correction: v_off_ini = -184.044 uV, v_off_fin = -189.042 uV 20:34:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.867 uVs 20:34:26 Integrated Voltage Measurement... 20:34:35 Voltage Offset Correction: v_off_ini = -185.957 uV, v_off_fin = -172.278 uV 20:34:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.332 uVs 20:34:35 Integrated Voltage Measurement... 20:34:44 Voltage Offset Correction: v_off_ini = -178.831 uV, v_off_fin = -191.986 uV 20:34:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.669 uVs 20:34:44 Integrated Voltage Measurement... 20:34:53 Voltage Offset Correction: v_off_ini = -179.371 uV, v_off_fin = -182.232 uV 20:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.208 uVs 20:34:55 I2X Average and RMS of Measurements VT = -95.283 +- 5.718 uVs I2X = 8.766 +- 0.526 uTm^2 20:35:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:35:03 Integrated Voltage Measurement... 20:35:12 Voltage Offset Correction: v_off_ini = -171.637 uV, v_off_fin = -181.832 uV 20:35:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.402 uVs 20:35:12 Integrated Voltage Measurement... 20:35:21 Voltage Offset Correction: v_off_ini = -171.898 uV, v_off_fin = -175.408 uV 20:35:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.580 uVs 20:35:21 Integrated Voltage Measurement... 20:35:30 Voltage Offset Correction: v_off_ini = -177.185 uV, v_off_fin = -187.638 uV 20:35:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.604 uVs 20:35:30 Integrated Voltage Measurement... 20:35:39 Voltage Offset Correction: v_off_ini = -199.274 uV, v_off_fin = -194.846 uV 20:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.096 uVs 20:35:39 Integrated Voltage Measurement... 20:35:48 Voltage Offset Correction: v_off_ini = -197.601 uV, v_off_fin = -197.637 uV 20:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.065 uVs 20:35:48 Integrated Voltage Measurement... 20:35:57 Voltage Offset Correction: v_off_ini = -203.559 uV, v_off_fin = -206.343 uV 20:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.079 uVs 20:36:00 I2Y Average and RMS of Measurements VT = -244.304 +- 8.607 uVs I2Y = -22.476 +- 0.792 uTm^2 20:36:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:36:08 Integrated Voltage Measurement... 20:36:17 Voltage Offset Correction: v_off_ini = -201.807 uV, v_off_fin = -207.429 uV 20:36:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.140 uVs 20:36:18 Integrated Voltage Measurement... 20:36:26 Voltage Offset Correction: v_off_ini = -204.197 uV, v_off_fin = -192.896 uV 20:36:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.706 uVs 20:36:27 Integrated Voltage Measurement... 20:36:35 Voltage Offset Correction: v_off_ini = -199.348 uV, v_off_fin = -197.724 uV 20:36:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.211 uVs 20:36:36 Integrated Voltage Measurement... 20:36:45 Voltage Offset Correction: v_off_ini = -181.460 uV, v_off_fin = -186.951 uV 20:36:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.642 uVs 20:36:45 Integrated Voltage Measurement... 20:36:54 Voltage Offset Correction: v_off_ini = -187.616 uV, v_off_fin = -188.519 uV 20:36:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.095 uVs 20:36:54 Integrated Voltage Measurement... 20:37:03 Voltage Offset Correction: v_off_ini = -180.197 uV, v_off_fin = -169.159 uV 20:37:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.633 uVs 20:37:07 I1X Average and RMS of Measurements VT = -113.571 +- 6.945 uVs I1X = 22.714 +- 1.389 uTm 20:37:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:37:14 Integrated Voltage Measurement... 20:37:23 Voltage Offset Correction: v_off_ini = -192.487 uV, v_off_fin = -202.253 uV 20:37:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.573 uVs 20:37:23 Integrated Voltage Measurement... 20:37:32 Voltage Offset Correction: v_off_ini = -182.833 uV, v_off_fin = -171.804 uV 20:37:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.180 uVs 20:37:32 Integrated Voltage Measurement... 20:37:41 Voltage Offset Correction: v_off_ini = -189.267 uV, v_off_fin = -198.159 uV 20:37:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.878 uVs 20:37:41 Integrated Voltage Measurement... 20:37:50 Voltage Offset Correction: v_off_ini = -182.336 uV, v_off_fin = -177.248 uV 20:37:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.809 uVs 20:37:50 Integrated Voltage Measurement... 20:37:59 Voltage Offset Correction: v_off_ini = -192.206 uV, v_off_fin = -202.361 uV 20:37:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.936 uVs 20:37:59 Integrated Voltage Measurement... 20:38:08 Voltage Offset Correction: v_off_ini = -177.779 uV, v_off_fin = -167.174 uV 20:38:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.711 uVs 20:38:12 I1Y Average and RMS of Measurements VT = -235.348 +- 3.730 uVs I1Y = -47.070 +- 0.746 uTm 20:38:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:38:20 Integrated Voltage Measurement... 20:38:29 Voltage Offset Correction: v_off_ini = -179.942 uV, v_off_fin = -186.814 uV 20:38:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.627 uVs 20:38:29 Integrated Voltage Measurement... 20:38:38 Voltage Offset Correction: v_off_ini = -180.989 uV, v_off_fin = -172.835 uV 20:38:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.849 uVs 20:38:38 Integrated Voltage Measurement... 20:38:47 Voltage Offset Correction: v_off_ini = -181.648 uV, v_off_fin = -183.459 uV 20:38:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.968 uVs 20:38:47 Integrated Voltage Measurement... 20:38:56 Voltage Offset Correction: v_off_ini = -191.981 uV, v_off_fin = -182.545 uV 20:38:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.893 uVs 20:38:56 Integrated Voltage Measurement... 20:39:05 Voltage Offset Correction: v_off_ini = -185.298 uV, v_off_fin = -192.270 uV 20:39:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.118 uVs 20:39:05 Integrated Voltage Measurement... 20:39:14 Voltage Offset Correction: v_off_ini = -182.671 uV, v_off_fin = -167.862 uV 20:39:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.022 uVs 20:39:16 I2X Average and RMS of Measurements VT = -101.413 +- 10.757 uVs I2X = 9.330 +- 0.990 uTm^2 20:39:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:39:24 Integrated Voltage Measurement... 20:39:33 Voltage Offset Correction: v_off_ini = -185.012 uV, v_off_fin = -185.065 uV 20:39:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.272 uVs 20:39:33 Integrated Voltage Measurement... 20:39:42 Voltage Offset Correction: v_off_ini = -193.541 uV, v_off_fin = -186.791 uV 20:39:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.599 uVs 20:39:42 Integrated Voltage Measurement... 20:39:51 Voltage Offset Correction: v_off_ini = -179.227 uV, v_off_fin = -171.933 uV 20:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.889 uVs 20:39:51 Integrated Voltage Measurement... 20:40:00 Voltage Offset Correction: v_off_ini = -173.701 uV, v_off_fin = -171.871 uV 20:40:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.496 uVs 20:40:00 Integrated Voltage Measurement... 20:40:09 Voltage Offset Correction: v_off_ini = -167.135 uV, v_off_fin = -178.470 uV 20:40:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.129 uVs 20:40:09 Integrated Voltage Measurement... 20:40:18 Voltage Offset Correction: v_off_ini = -171.465 uV, v_off_fin = -166.304 uV 20:40:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.361 uVs 20:40:20 I2Y Average and RMS of Measurements VT = -254.958 +- 6.603 uVs I2Y = -23.456 +- 0.607 uTm^2 20:40:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:40:29 Integrated Voltage Measurement... 20:40:38 Voltage Offset Correction: v_off_ini = -164.400 uV, v_off_fin = -171.925 uV 20:40:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.277 uVs 20:40:38 Integrated Voltage Measurement... 20:40:47 Voltage Offset Correction: v_off_ini = -169.805 uV, v_off_fin = -181.659 uV 20:40:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.084 uVs 20:40:47 Integrated Voltage Measurement... 20:40:56 Voltage Offset Correction: v_off_ini = -173.294 uV, v_off_fin = -174.194 uV 20:40:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.835 uVs 20:40:56 Integrated Voltage Measurement... 20:41:05 Voltage Offset Correction: v_off_ini = -160.301 uV, v_off_fin = -164.402 uV 20:41:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.957 uVs 20:41:05 Integrated Voltage Measurement... 20:41:14 Voltage Offset Correction: v_off_ini = -165.720 uV, v_off_fin = -165.720 uV 20:41:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.896 uVs 20:41:14 Integrated Voltage Measurement... 20:41:23 Voltage Offset Correction: v_off_ini = -165.154 uV, v_off_fin = -156.063 uV 20:41:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.541 uVs 20:41:28 I1X Average and RMS of Measurements VT = -114.932 +- 2.654 uVs I1X = 22.986 +- 0.531 uTm 20:41:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:41:34 Integrated Voltage Measurement... 20:41:43 Voltage Offset Correction: v_off_ini = -161.206 uV, v_off_fin = -172.848 uV 20:41:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.911 uVs 20:41:43 Integrated Voltage Measurement... 20:41:52 Voltage Offset Correction: v_off_ini = -169.217 uV, v_off_fin = -160.730 uV 20:41:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.741 uVs 20:41:52 Integrated Voltage Measurement... 20:42:01 Voltage Offset Correction: v_off_ini = -151.260 uV, v_off_fin = -166.015 uV 20:42:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.763 uVs 20:42:01 Integrated Voltage Measurement... 20:42:10 Voltage Offset Correction: v_off_ini = -167.320 uV, v_off_fin = -156.005 uV 20:42:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.211 uVs 20:42:10 Integrated Voltage Measurement... 20:42:19 Voltage Offset Correction: v_off_ini = -155.035 uV, v_off_fin = -175.191 uV 20:42:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.439 uVs 20:42:19 Integrated Voltage Measurement... 20:42:28 Voltage Offset Correction: v_off_ini = -174.873 uV, v_off_fin = -153.668 uV 20:42:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.693 uVs 20:42:33 I1Y Average and RMS of Measurements VT = -235.293 +- 6.873 uVs I1Y = -47.059 +- 1.375 uTm 20:42:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:42:40 Integrated Voltage Measurement... 20:42:49 Voltage Offset Correction: v_off_ini = -172.407 uV, v_off_fin = -172.446 uV 20:42:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -108.725 uVs 20:42:49 Integrated Voltage Measurement... 20:42:58 Voltage Offset Correction: v_off_ini = -154.195 uV, v_off_fin = -149.974 uV 20:42:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.569 uVs 20:42:58 Integrated Voltage Measurement... 20:43:07 Voltage Offset Correction: v_off_ini = -158.300 uV, v_off_fin = -154.325 uV 20:43:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.845 uVs 20:43:07 Integrated Voltage Measurement... 20:43:16 Voltage Offset Correction: v_off_ini = -151.816 uV, v_off_fin = -145.352 uV 20:43:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.351 uVs 20:43:17 Integrated Voltage Measurement... 20:43:26 Voltage Offset Correction: v_off_ini = -156.116 uV, v_off_fin = -163.118 uV 20:43:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.835 uVs 20:43:26 Integrated Voltage Measurement... 20:43:35 Voltage Offset Correction: v_off_ini = -163.175 uV, v_off_fin = -152.919 uV 20:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.710 uVs 20:43:37 I2X Average and RMS of Measurements VT = -103.506 +- 2.225 uVs I2X = 9.523 +- 0.204 uTm^2 20:43:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:43:45 Integrated Voltage Measurement... 20:43:54 Voltage Offset Correction: v_off_ini = -154.516 uV, v_off_fin = -162.000 uV 20:43:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.234 uVs 20:43:54 Integrated Voltage Measurement... 20:44:03 Voltage Offset Correction: v_off_ini = -152.892 uV, v_off_fin = -154.329 uV 20:44:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.560 uVs 20:44:03 Integrated Voltage Measurement... 20:44:12 Voltage Offset Correction: v_off_ini = -149.238 uV, v_off_fin = -151.402 uV 20:44:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.796 uVs 20:44:12 Integrated Voltage Measurement... 20:44:21 Voltage Offset Correction: v_off_ini = -149.371 uV, v_off_fin = -146.717 uV 20:44:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.714 uVs 20:44:21 Integrated Voltage Measurement... 20:44:30 Voltage Offset Correction: v_off_ini = -151.766 uV, v_off_fin = -148.839 uV 20:44:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.611 uVs 20:44:30 Integrated Voltage Measurement... 20:44:39 Voltage Offset Correction: v_off_ini = -139.560 uV, v_off_fin = -143.898 uV 20:44:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.415 uVs 20:44:41 I2Y Average and RMS of Measurements VT = -248.722 +- 7.914 uVs I2Y = -22.882 +- 0.728 uTm^2 20:44:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:44:53 Integrated Voltage Measurement... 20:45:02 Voltage Offset Correction: v_off_ini = -139.928 uV, v_off_fin = -147.277 uV 20:45:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.662 uVs 20:45:02 Integrated Voltage Measurement... 20:45:11 Voltage Offset Correction: v_off_ini = -144.733 uV, v_off_fin = -147.469 uV 20:45:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.583 uVs 20:45:11 Integrated Voltage Measurement... 20:45:20 Voltage Offset Correction: v_off_ini = -143.460 uV, v_off_fin = -157.795 uV 20:45:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.090 uVs 20:45:20 Integrated Voltage Measurement... 20:45:29 Voltage Offset Correction: v_off_ini = -150.318 uV, v_off_fin = -143.334 uV 20:45:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.822 uVs 20:45:29 Integrated Voltage Measurement... 20:45:38 Voltage Offset Correction: v_off_ini = -129.770 uV, v_off_fin = -144.204 uV 20:45:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.645 uVs 20:45:38 Integrated Voltage Measurement... 20:45:47 Voltage Offset Correction: v_off_ini = -138.278 uV, v_off_fin = -126.288 uV 20:45:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.792 uVs 20:45:52 I1X Average and RMS of Measurements VT = -100.266 +- 1.387 uVs I1X = 20.054 +- 0.278 uTm 20:45:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:45:58 Integrated Voltage Measurement... 20:46:07 Voltage Offset Correction: v_off_ini = -143.439 uV, v_off_fin = -151.502 uV 20:46:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.217 uVs 20:46:07 Integrated Voltage Measurement... 20:46:16 Voltage Offset Correction: v_off_ini = -145.216 uV, v_off_fin = -149.625 uV 20:46:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.369 uVs 20:46:16 Integrated Voltage Measurement... 20:46:25 Voltage Offset Correction: v_off_ini = -151.115 uV, v_off_fin = -157.138 uV 20:46:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.200 uVs 20:46:25 Integrated Voltage Measurement... 20:46:34 Voltage Offset Correction: v_off_ini = -144.664 uV, v_off_fin = -131.379 uV 20:46:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.917 uVs 20:46:34 Integrated Voltage Measurement... 20:46:43 Voltage Offset Correction: v_off_ini = -146.370 uV, v_off_fin = -158.305 uV 20:46:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.884 uVs 20:46:43 Integrated Voltage Measurement... 20:46:52 Voltage Offset Correction: v_off_ini = -159.416 uV, v_off_fin = -139.302 uV 20:46:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.732 uVs 20:46:57 I1Y Average and RMS of Measurements VT = -226.720 +- 3.023 uVs I1Y = -45.345 +- 0.604 uTm 20:46:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:47:02 Integrated Voltage Measurement... 20:47:11 Voltage Offset Correction: v_off_ini = -140.232 uV, v_off_fin = -135.753 uV 20:47:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.332 uVs 20:47:11 Integrated Voltage Measurement... 20:47:20 Voltage Offset Correction: v_off_ini = -124.532 uV, v_off_fin = -125.365 uV 20:47:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.483 uVs 20:47:20 Integrated Voltage Measurement... 20:47:29 Voltage Offset Correction: v_off_ini = -137.420 uV, v_off_fin = -157.900 uV 20:47:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.781 uVs 20:47:29 Integrated Voltage Measurement... 20:47:38 Voltage Offset Correction: v_off_ini = -138.665 uV, v_off_fin = -129.473 uV 20:47:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.965 uVs 20:47:38 Integrated Voltage Measurement... 20:47:47 Voltage Offset Correction: v_off_ini = -137.074 uV, v_off_fin = -152.868 uV 20:47:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.792 uVs 20:47:47 Integrated Voltage Measurement... 20:47:56 Voltage Offset Correction: v_off_ini = -134.476 uV, v_off_fin = -136.079 uV 20:47:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.785 uVs 20:47:58 I2X Average and RMS of Measurements VT = -104.356 +- 3.315 uVs I2X = 9.601 +- 0.305 uTm^2 20:48:01 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:48:04 Integrated Voltage Measurement... 20:48:12 Voltage Offset Correction: v_off_ini = -133.227 uV, v_off_fin = -150.055 uV 20:48:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.413 uVs 20:48:13 Integrated Voltage Measurement... 20:48:22 Voltage Offset Correction: v_off_ini = -166.335 uV, v_off_fin = -153.727 uV 20:48:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.160 uVs 20:48:22 Integrated Voltage Measurement... 20:48:31 Voltage Offset Correction: v_off_ini = -162.455 uV, v_off_fin = -157.959 uV 20:48:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.144 uVs 20:48:31 Integrated Voltage Measurement... 20:48:40 Voltage Offset Correction: v_off_ini = -160.235 uV, v_off_fin = -157.814 uV 20:48:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.457 uVs 20:48:40 Integrated Voltage Measurement... 20:48:49 Voltage Offset Correction: v_off_ini = -146.849 uV, v_off_fin = -158.448 uV 20:48:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.812 uVs 20:48:49 Integrated Voltage Measurement... 20:48:58 Voltage Offset Correction: v_off_ini = -159.980 uV, v_off_fin = -153.776 uV 20:48:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.543 uVs 20:49:00 I2Y Average and RMS of Measurements VT = -247.421 +- 4.908 uVs I2Y = -22.763 +- 0.452 uTm^2 20:49:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:49:08 Integrated Voltage Measurement... 20:49:17 Voltage Offset Correction: v_off_ini = -158.319 uV, v_off_fin = -166.569 uV 20:49:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.898 uVs 20:49:18 Integrated Voltage Measurement... 20:49:26 Voltage Offset Correction: v_off_ini = -166.652 uV, v_off_fin = -180.639 uV 20:49:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.982 uVs 20:49:27 Integrated Voltage Measurement... 20:49:36 Voltage Offset Correction: v_off_ini = -172.413 uV, v_off_fin = -196.055 uV 20:49:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.140 uVs 20:49:36 Integrated Voltage Measurement... 20:49:45 Voltage Offset Correction: v_off_ini = -187.763 uV, v_off_fin = -183.947 uV 20:49:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.050 uVs 20:49:45 Integrated Voltage Measurement... 20:49:54 Voltage Offset Correction: v_off_ini = -180.308 uV, v_off_fin = -187.649 uV 20:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.907 uVs 20:49:54 Integrated Voltage Measurement... 20:50:03 Voltage Offset Correction: v_off_ini = -167.957 uV, v_off_fin = -175.144 uV 20:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.720 uVs 20:50:07 I1X Average and RMS of Measurements VT = -107.283 +- 4.299 uVs I1X = 21.457 +- 0.860 uTm 20:50:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:50:14 Integrated Voltage Measurement... 20:50:23 Voltage Offset Correction: v_off_ini = -183.001 uV, v_off_fin = -183.517 uV 20:50:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.375 uVs 20:50:23 Integrated Voltage Measurement... 20:50:32 Voltage Offset Correction: v_off_ini = -172.086 uV, v_off_fin = -160.669 uV 20:50:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.109 uVs 20:50:32 Integrated Voltage Measurement... 20:50:41 Voltage Offset Correction: v_off_ini = -173.775 uV, v_off_fin = -195.670 uV 20:50:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.767 uVs 20:50:41 Integrated Voltage Measurement... 20:50:50 Voltage Offset Correction: v_off_ini = -178.350 uV, v_off_fin = -166.807 uV 20:50:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.751 uVs 20:50:50 Integrated Voltage Measurement... 20:50:59 Voltage Offset Correction: v_off_ini = -183.870 uV, v_off_fin = -179.537 uV 20:50:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.489 uVs 20:50:59 Integrated Voltage Measurement... 20:51:08 Voltage Offset Correction: v_off_ini = -190.844 uV, v_off_fin = -181.177 uV 20:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.711 uVs 20:51:12 I1Y Average and RMS of Measurements VT = -227.200 +- 2.871 uVs I1Y = -45.440 +- 0.574 uTm 20:51:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:51:17 Integrated Voltage Measurement... 20:51:26 Voltage Offset Correction: v_off_ini = -171.497 uV, v_off_fin = -182.350 uV 20:51:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.880 uVs 20:51:26 Integrated Voltage Measurement... 20:51:35 Voltage Offset Correction: v_off_ini = -175.594 uV, v_off_fin = -179.021 uV 20:51:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.025 uVs 20:51:35 Integrated Voltage Measurement... 20:51:44 Voltage Offset Correction: v_off_ini = -170.677 uV, v_off_fin = -186.934 uV 20:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.266 uVs 20:51:44 Integrated Voltage Measurement... 20:51:53 Voltage Offset Correction: v_off_ini = -182.282 uV, v_off_fin = -179.335 uV 20:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.536 uVs 20:51:53 Integrated Voltage Measurement... 20:52:02 Voltage Offset Correction: v_off_ini = -183.015 uV, v_off_fin = -186.412 uV 20:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.415 uVs 20:52:02 Integrated Voltage Measurement... 20:52:11 Voltage Offset Correction: v_off_ini = -163.785 uV, v_off_fin = -153.990 uV 20:52:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.442 uVs 20:52:14 I2X Average and RMS of Measurements VT = -100.594 +- 8.789 uVs I2X = 9.255 +- 0.809 uTm^2 20:52:16 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:52:19 Integrated Voltage Measurement... 20:52:28 Voltage Offset Correction: v_off_ini = -162.772 uV, v_off_fin = -164.708 uV 20:52:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.364 uVs 20:52:28 Integrated Voltage Measurement... 20:52:37 Voltage Offset Correction: v_off_ini = -160.962 uV, v_off_fin = -175.243 uV 20:52:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.312 uVs 20:52:37 Integrated Voltage Measurement... 20:52:46 Voltage Offset Correction: v_off_ini = -165.011 uV, v_off_fin = -168.167 uV 20:52:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.880 uVs 20:52:46 Integrated Voltage Measurement... 20:52:55 Voltage Offset Correction: v_off_ini = -162.486 uV, v_off_fin = -163.418 uV 20:52:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.530 uVs 20:52:55 Integrated Voltage Measurement... 20:53:04 Voltage Offset Correction: v_off_ini = -152.023 uV, v_off_fin = -151.216 uV 20:53:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.317 uVs 20:53:04 Integrated Voltage Measurement... 20:53:13 Voltage Offset Correction: v_off_ini = -146.645 uV, v_off_fin = -140.676 uV 20:53:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.824 uVs 20:53:15 I2Y Average and RMS of Measurements VT = -246.205 +- 4.841 uVs I2Y = -22.651 +- 0.445 uTm^2 20:53:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:53:24 Integrated Voltage Measurement... 20:53:33 Voltage Offset Correction: v_off_ini = -157.710 uV, v_off_fin = -163.311 uV 20:53:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.515 uVs 20:53:33 Integrated Voltage Measurement... 20:53:42 Voltage Offset Correction: v_off_ini = -156.517 uV, v_off_fin = -151.821 uV 20:53:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 120.753 uVs 20:53:42 Integrated Voltage Measurement... 20:53:51 Voltage Offset Correction: v_off_ini = -168.609 uV, v_off_fin = -163.242 uV 20:53:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.448 uVs 20:53:51 Integrated Voltage Measurement... 20:54:00 Voltage Offset Correction: v_off_ini = -150.320 uV, v_off_fin = -142.186 uV 20:54:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.389 uVs 20:54:00 Integrated Voltage Measurement... 20:54:09 Voltage Offset Correction: v_off_ini = -149.534 uV, v_off_fin = -153.989 uV 20:54:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.633 uVs 20:54:09 Integrated Voltage Measurement... 20:54:18 Voltage Offset Correction: v_off_ini = -168.690 uV, v_off_fin = -148.139 uV 20:54:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.971 uVs 20:54:22 I1X Average and RMS of Measurements VT = -113.618 +- 4.401 uVs I1X = 22.725 +- 0.879 uTm 20:54:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:54:29 Integrated Voltage Measurement... 20:54:38 Voltage Offset Correction: v_off_ini = -146.625 uV, v_off_fin = -155.459 uV 20:54:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.696 uVs 20:54:38 Integrated Voltage Measurement... 20:54:47 Voltage Offset Correction: v_off_ini = -148.135 uV, v_off_fin = -133.292 uV 20:54:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.253 uVs 20:54:47 Integrated Voltage Measurement... 20:54:56 Voltage Offset Correction: v_off_ini = -152.216 uV, v_off_fin = -146.074 uV 20:54:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.716 uVs 20:54:56 Integrated Voltage Measurement... 20:55:05 Voltage Offset Correction: v_off_ini = -144.616 uV, v_off_fin = -138.864 uV 20:55:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.097 uVs 20:55:05 Integrated Voltage Measurement... 20:55:14 Voltage Offset Correction: v_off_ini = -142.079 uV, v_off_fin = -163.625 uV 20:55:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.201 uVs 20:55:14 Integrated Voltage Measurement... 20:55:23 Voltage Offset Correction: v_off_ini = -158.557 uV, v_off_fin = -140.458 uV 20:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.921 uVs 20:55:27 I1Y Average and RMS of Measurements VT = -225.814 +- 4.791 uVs I1Y = -45.163 +- 0.958 uTm 20:55:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:55:32 Integrated Voltage Measurement... 20:55:41 Voltage Offset Correction: v_off_ini = -176.500 uV, v_off_fin = -177.687 uV 20:55:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.770 uVs 20:55:41 Integrated Voltage Measurement... 20:55:50 Voltage Offset Correction: v_off_ini = -156.084 uV, v_off_fin = -150.669 uV 20:55:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.501 uVs 20:55:50 Integrated Voltage Measurement... 20:55:59 Voltage Offset Correction: v_off_ini = -163.081 uV, v_off_fin = -170.686 uV 20:55:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.193 uVs 20:55:59 Integrated Voltage Measurement... 20:56:08 Voltage Offset Correction: v_off_ini = -159.026 uV, v_off_fin = -148.761 uV 20:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.925 uVs 20:56:08 Integrated Voltage Measurement... 20:56:17 Voltage Offset Correction: v_off_ini = -159.301 uV, v_off_fin = -161.168 uV 20:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.225 uVs 20:56:17 Integrated Voltage Measurement... 20:56:26 Voltage Offset Correction: v_off_ini = -149.895 uV, v_off_fin = -151.378 uV 20:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.002 uVs 20:56:29 I2X Average and RMS of Measurements VT = -100.603 +- 5.180 uVs I2X = 9.255 +- 0.477 uTm^2 20:56:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:56:34 Integrated Voltage Measurement... 20:56:43 Voltage Offset Correction: v_off_ini = -168.037 uV, v_off_fin = -173.745 uV 20:56:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.480 uVs 20:56:43 Integrated Voltage Measurement... 20:56:52 Voltage Offset Correction: v_off_ini = -160.855 uV, v_off_fin = -162.073 uV 20:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.065 uVs 20:56:52 Integrated Voltage Measurement... 20:57:01 Voltage Offset Correction: v_off_ini = -164.993 uV, v_off_fin = -168.559 uV 20:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.263 uVs 20:57:01 Integrated Voltage Measurement... 20:57:10 Voltage Offset Correction: v_off_ini = -157.086 uV, v_off_fin = -172.752 uV 20:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.660 uVs 20:57:10 Integrated Voltage Measurement... 20:57:19 Voltage Offset Correction: v_off_ini = -173.141 uV, v_off_fin = -173.771 uV 20:57:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.323 uVs 20:57:19 Integrated Voltage Measurement... 20:57:28 Voltage Offset Correction: v_off_ini = -179.756 uV, v_off_fin = -176.021 uV 20:57:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.326 uVs 20:57:31 I2Y Average and RMS of Measurements VT = -242.186 +- 5.056 uVs I2Y = -22.281 +- 0.465 uTm^2 20:57:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:57:39 Integrated Voltage Measurement... 20:57:48 Voltage Offset Correction: v_off_ini = -159.143 uV, v_off_fin = -174.261 uV 20:57:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.249 uVs 20:57:48 Integrated Voltage Measurement... 20:57:57 Voltage Offset Correction: v_off_ini = -159.235 uV, v_off_fin = -172.524 uV 20:57:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.610 uVs 20:57:57 Integrated Voltage Measurement... 20:58:06 Voltage Offset Correction: v_off_ini = -174.371 uV, v_off_fin = -179.884 uV 20:58:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.405 uVs 20:58:06 Integrated Voltage Measurement... 20:58:15 Voltage Offset Correction: v_off_ini = -174.758 uV, v_off_fin = -162.732 uV 20:58:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.785 uVs 20:58:15 Integrated Voltage Measurement... 20:58:24 Voltage Offset Correction: v_off_ini = -171.378 uV, v_off_fin = -169.209 uV 20:58:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.577 uVs 20:58:24 Integrated Voltage Measurement... 20:58:33 Voltage Offset Correction: v_off_ini = -171.921 uV, v_off_fin = -164.632 uV 20:58:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.710 uVs 20:58:37 I1X Average and RMS of Measurements VT = -98.056 +- 2.770 uVs I1X = 19.612 +- 0.555 uTm 20:58:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:58:44 Integrated Voltage Measurement... 20:58:53 Voltage Offset Correction: v_off_ini = -180.932 uV, v_off_fin = -199.990 uV 20:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.651 uVs 20:58:53 Integrated Voltage Measurement... 20:59:02 Voltage Offset Correction: v_off_ini = -183.140 uV, v_off_fin = -194.146 uV 20:59:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.810 uVs 20:59:02 Integrated Voltage Measurement... 20:59:11 Voltage Offset Correction: v_off_ini = -192.207 uV, v_off_fin = -199.322 uV 20:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.050 uVs 20:59:11 Integrated Voltage Measurement... 20:59:20 Voltage Offset Correction: v_off_ini = -194.585 uV, v_off_fin = -170.362 uV 20:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.253 uVs 20:59:20 Integrated Voltage Measurement... 20:59:29 Voltage Offset Correction: v_off_ini = -177.871 uV, v_off_fin = -192.009 uV 20:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.072 uVs 20:59:29 Integrated Voltage Measurement... 20:59:38 Voltage Offset Correction: v_off_ini = -192.118 uV, v_off_fin = -174.666 uV 20:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.642 uVs 20:59:42 I1Y Average and RMS of Measurements VT = -229.080 +- 3.881 uVs I1Y = -45.816 +- 0.776 uTm 20:59:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:59:47 Integrated Voltage Measurement... 20:59:56 Voltage Offset Correction: v_off_ini = -201.141 uV, v_off_fin = -187.374 uV 20:59:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.056 uVs 20:59:56 Integrated Voltage Measurement... 21:00:05 Voltage Offset Correction: v_off_ini = -176.134 uV, v_off_fin = -184.349 uV 21:00:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.324 uVs 21:00:05 Integrated Voltage Measurement... 21:00:14 Voltage Offset Correction: v_off_ini = -189.583 uV, v_off_fin = -209.706 uV 21:00:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -89.065 uVs 21:00:14 Integrated Voltage Measurement... 21:00:23 Voltage Offset Correction: v_off_ini = -192.292 uV, v_off_fin = -186.624 uV 21:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.970 uVs 21:00:23 Integrated Voltage Measurement... 21:00:32 Voltage Offset Correction: v_off_ini = -191.586 uV, v_off_fin = -200.666 uV 21:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.798 uVs 21:00:32 Integrated Voltage Measurement... 21:00:41 Voltage Offset Correction: v_off_ini = -197.472 uV, v_off_fin = -178.959 uV 21:00:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.525 uVs 21:00:44 I2X Average and RMS of Measurements VT = -89.289 +- 10.080 uVs I2X = 8.215 +- 0.927 uTm^2 21:00:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 21:00:49 Integrated Voltage Measurement... 21:00:58 Voltage Offset Correction: v_off_ini = -191.126 uV, v_off_fin = -194.080 uV 21:00:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.510 uVs 21:00:58 Integrated Voltage Measurement... 21:01:07 Voltage Offset Correction: v_off_ini = -192.419 uV, v_off_fin = -182.614 uV 21:01:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.885 uVs 21:01:07 Integrated Voltage Measurement... 21:01:16 Voltage Offset Correction: v_off_ini = -172.662 uV, v_off_fin = -186.577 uV 21:01:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.492 uVs 21:01:16 Integrated Voltage Measurement... 21:01:25 Voltage Offset Correction: v_off_ini = -168.813 uV, v_off_fin = -174.988 uV 21:01:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.363 uVs 21:01:25 Integrated Voltage Measurement... 21:01:34 Voltage Offset Correction: v_off_ini = -171.400 uV, v_off_fin = -169.104 uV 21:01:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.489 uVs 21:01:34 Integrated Voltage Measurement... 21:01:43 Voltage Offset Correction: v_off_ini = -162.251 uV, v_off_fin = -172.789 uV 21:01:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.358 uVs 21:01:46 I2Y Average and RMS of Measurements VT = -239.350 +- 2.055 uVs I2Y = -22.020 +- 0.189 uTm^2 21:01:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:01:54 Integrated Voltage Measurement... 21:02:03 Voltage Offset Correction: v_off_ini = -151.958 uV, v_off_fin = -154.877 uV 21:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.724 uVs 21:02:03 Integrated Voltage Measurement... 21:02:12 Voltage Offset Correction: v_off_ini = -147.877 uV, v_off_fin = -151.637 uV 21:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.650 uVs 21:02:12 Integrated Voltage Measurement... 21:02:21 Voltage Offset Correction: v_off_ini = -146.372 uV, v_off_fin = -140.143 uV 21:02:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.653 uVs 21:02:21 Integrated Voltage Measurement... 21:02:30 Voltage Offset Correction: v_off_ini = -148.503 uV, v_off_fin = -139.713 uV 21:02:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.846 uVs 21:02:30 Integrated Voltage Measurement... 21:02:39 Voltage Offset Correction: v_off_ini = -141.364 uV, v_off_fin = -147.542 uV 21:02:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.043 uVs 21:02:39 Integrated Voltage Measurement... 21:02:48 Voltage Offset Correction: v_off_ini = -148.729 uV, v_off_fin = -157.202 uV 21:02:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 105.787 uVs 21:02:52 I1X Average and RMS of Measurements VT = -88.784 +- 3.334 uVs I1X = 17.758 +- 0.667 uTm 21:02:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:02:59 Integrated Voltage Measurement... 21:03:08 Voltage Offset Correction: v_off_ini = -153.120 uV, v_off_fin = -157.814 uV 21:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.271 uVs 21:03:08 Integrated Voltage Measurement... 21:03:17 Voltage Offset Correction: v_off_ini = -138.688 uV, v_off_fin = -138.372 uV 21:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.075 uVs 21:03:17 Integrated Voltage Measurement... 21:03:26 Voltage Offset Correction: v_off_ini = -159.501 uV, v_off_fin = -166.632 uV 21:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.329 uVs 21:03:26 Integrated Voltage Measurement... 21:03:35 Voltage Offset Correction: v_off_ini = -144.261 uV, v_off_fin = -135.562 uV 21:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.565 uVs 21:03:35 Integrated Voltage Measurement... 21:03:44 Voltage Offset Correction: v_off_ini = -154.566 uV, v_off_fin = -169.477 uV 21:03:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.490 uVs 21:03:44 Integrated Voltage Measurement... 21:03:53 Voltage Offset Correction: v_off_ini = -164.267 uV, v_off_fin = -137.870 uV 21:03:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.462 uVs 21:03:57 I1Y Average and RMS of Measurements VT = -214.699 +- 4.622 uVs I1Y = -42.940 +- 0.924 uTm 21:04:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:04:02 Integrated Voltage Measurement... 21:04:11 Voltage Offset Correction: v_off_ini = -142.835 uV, v_off_fin = -149.086 uV 21:04:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.811 uVs 21:04:11 Integrated Voltage Measurement... 21:04:20 Voltage Offset Correction: v_off_ini = -152.233 uV, v_off_fin = -133.688 uV 21:04:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.461 uVs 21:04:20 Integrated Voltage Measurement... 21:04:29 Voltage Offset Correction: v_off_ini = -147.790 uV, v_off_fin = -165.816 uV 21:04:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.992 uVs 21:04:30 Integrated Voltage Measurement... 21:04:39 Voltage Offset Correction: v_off_ini = -143.957 uV, v_off_fin = -142.845 uV 21:04:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.818 uVs 21:04:39 Integrated Voltage Measurement... 21:04:48 Voltage Offset Correction: v_off_ini = -136.949 uV, v_off_fin = -163.864 uV 21:04:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.559 uVs 21:04:48 Integrated Voltage Measurement... 21:04:57 Voltage Offset Correction: v_off_ini = -148.700 uV, v_off_fin = -156.374 uV 21:04:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.416 uVs 21:04:59 I2X Average and RMS of Measurements VT = -79.343 +- 2.529 uVs I2X = 7.300 +- 0.233 uTm^2 21:05:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 21:05:04 Integrated Voltage Measurement... 21:05:13 Voltage Offset Correction: v_off_ini = -178.841 uV, v_off_fin = -188.051 uV 21:05:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.972 uVs 21:05:13 Integrated Voltage Measurement... 21:05:22 Voltage Offset Correction: v_off_ini = -177.324 uV, v_off_fin = -160.501 uV 21:05:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.363 uVs 21:05:22 Integrated Voltage Measurement... 21:05:31 Voltage Offset Correction: v_off_ini = -162.485 uV, v_off_fin = -163.824 uV 21:05:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.151 uVs 21:05:31 Integrated Voltage Measurement... 21:05:40 Voltage Offset Correction: v_off_ini = -167.045 uV, v_off_fin = -171.878 uV 21:05:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.942 uVs 21:05:40 Integrated Voltage Measurement... 21:05:49 Voltage Offset Correction: v_off_ini = -172.570 uV, v_off_fin = -170.323 uV 21:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.268 uVs 21:05:49 Integrated Voltage Measurement... 21:05:58 Voltage Offset Correction: v_off_ini = -178.207 uV, v_off_fin = -176.063 uV 21:05:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.356 uVs 21:06:01 I2Y Average and RMS of Measurements VT = -244.675 +- 8.507 uVs I2Y = -22.510 +- 0.783 uTm^2 21:06:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:42:54 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm