SLAC Magnetic Measurements Date: 11-13-2025 Time: 11:05:21 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16339 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 11:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:31 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:32 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:34 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:35 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:06:19 Integrated Voltage Measurement... 11:06:28 Voltage Offset Correction: v_off_ini = 1058.575 uV, v_off_fin = 1055.807 uV 11:06:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.441 uVs 11:06:28 Integrated Voltage Measurement... 11:06:37 Voltage Offset Correction: v_off_ini = 1053.521 uV, v_off_fin = 1063.224 uV 11:06:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.585 uVs 11:06:37 Integrated Voltage Measurement... 11:06:46 Voltage Offset Correction: v_off_ini = 1063.462 uV, v_off_fin = 1061.438 uV 11:06:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.942 uVs 11:06:46 Integrated Voltage Measurement... 11:06:55 Voltage Offset Correction: v_off_ini = 1066.600 uV, v_off_fin = 1069.050 uV 11:06:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 104.190 uVs 11:06:55 Integrated Voltage Measurement... 11:07:04 Voltage Offset Correction: v_off_ini = 1059.880 uV, v_off_fin = 1054.570 uV 11:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.465 uVs 11:07:04 Integrated Voltage Measurement... 11:07:13 Voltage Offset Correction: v_off_ini = 1068.627 uV, v_off_fin = 1058.955 uV 11:07:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.961 uVs 11:07:17 I1X Average and RMS of Measurements VT = -102.764 +- 7.881 uVs I1X = 20.554 +- 1.577 uTm 11:07:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:07:24 Integrated Voltage Measurement... 11:07:33 Voltage Offset Correction: v_off_ini = 1044.771 uV, v_off_fin = 1043.008 uV 11:07:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.395 uVs 11:07:33 Integrated Voltage Measurement... 11:07:42 Voltage Offset Correction: v_off_ini = 1062.156 uV, v_off_fin = 1047.432 uV 11:07:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.578 uVs 11:07:42 Integrated Voltage Measurement... 11:07:51 Voltage Offset Correction: v_off_ini = 1045.151 uV, v_off_fin = 1028.723 uV 11:07:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.490 uVs 11:07:51 Integrated Voltage Measurement... 11:08:00 Voltage Offset Correction: v_off_ini = 1042.370 uV, v_off_fin = 1054.356 uV 11:08:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.531 uVs 11:08:00 Integrated Voltage Measurement... 11:08:09 Voltage Offset Correction: v_off_ini = 1051.004 uV, v_off_fin = 1045.144 uV 11:08:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.615 uVs 11:08:09 Integrated Voltage Measurement... 11:08:18 Voltage Offset Correction: v_off_ini = 1049.748 uV, v_off_fin = 1059.625 uV 11:08:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.445 uVs 11:08:22 I1Y Average and RMS of Measurements VT = -234.176 +- 7.207 uVs I1Y = -46.835 +- 1.441 uTm 11:08:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:08:30 Integrated Voltage Measurement... 11:08:39 Voltage Offset Correction: v_off_ini = 1054.279 uV, v_off_fin = 1049.877 uV 11:08:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -138.150 uVs 11:08:39 Integrated Voltage Measurement... 11:08:48 Voltage Offset Correction: v_off_ini = 1044.922 uV, v_off_fin = 1046.328 uV 11:08:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 137.128 uVs 11:08:48 Integrated Voltage Measurement... 11:08:57 Voltage Offset Correction: v_off_ini = 1039.601 uV, v_off_fin = 1046.007 uV 11:08:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.913 uVs 11:08:57 Integrated Voltage Measurement... 11:09:06 Voltage Offset Correction: v_off_ini = 1049.082 uV, v_off_fin = 1057.670 uV 11:09:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.111 uVs 11:09:06 Integrated Voltage Measurement... 11:09:15 Voltage Offset Correction: v_off_ini = 1042.683 uV, v_off_fin = 1044.753 uV 11:09:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.784 uVs 11:09:15 Integrated Voltage Measurement... 11:09:24 Voltage Offset Correction: v_off_ini = 1044.765 uV, v_off_fin = 1061.478 uV 11:09:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.679 uVs 11:09:27 I2X Average and RMS of Measurements VT = -130.627 +- 5.396 uVs I2X = 12.018 +- 0.496 uTm^2 11:09:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:09:34 Integrated Voltage Measurement... 11:09:43 Voltage Offset Correction: v_off_ini = 1049.589 uV, v_off_fin = 1040.355 uV 11:09:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -423.687 uVs 11:09:43 Integrated Voltage Measurement... 11:09:52 Voltage Offset Correction: v_off_ini = 1028.511 uV, v_off_fin = 1046.981 uV 11:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 398.767 uVs 11:09:53 Integrated Voltage Measurement... 11:10:02 Voltage Offset Correction: v_off_ini = 1047.690 uV, v_off_fin = 1029.061 uV 11:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -426.011 uVs 11:10:02 Integrated Voltage Measurement... 11:10:11 Voltage Offset Correction: v_off_ini = 1033.791 uV, v_off_fin = 1038.051 uV 11:10:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 410.815 uVs 11:10:11 Integrated Voltage Measurement... 11:10:20 Voltage Offset Correction: v_off_ini = 1041.912 uV, v_off_fin = 1042.732 uV 11:10:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.653 uVs 11:10:20 Integrated Voltage Measurement... 11:10:29 Voltage Offset Correction: v_off_ini = 1040.885 uV, v_off_fin = 1034.132 uV 11:10:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 408.865 uVs 11:10:31 I2Y Average and RMS of Measurements VT = -411.300 +- 5.779 uVs I2Y = -37.840 +- 0.532 uTm^2 11:10:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:10:40 Integrated Voltage Measurement... 11:10:49 Voltage Offset Correction: v_off_ini = 1063.935 uV, v_off_fin = 1043.465 uV 11:10:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.065 uVs 11:10:49 Integrated Voltage Measurement... 11:10:58 Voltage Offset Correction: v_off_ini = 1051.093 uV, v_off_fin = 1045.610 uV 11:10:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.929 uVs 11:10:58 Integrated Voltage Measurement... 11:11:07 Voltage Offset Correction: v_off_ini = 1041.109 uV, v_off_fin = 1040.543 uV 11:11:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.983 uVs 11:11:07 Integrated Voltage Measurement... 11:11:16 Voltage Offset Correction: v_off_ini = 1064.145 uV, v_off_fin = 1054.231 uV 11:11:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.851 uVs 11:11:16 Integrated Voltage Measurement... 11:11:25 Voltage Offset Correction: v_off_ini = 1039.553 uV, v_off_fin = 1035.385 uV 11:11:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.674 uVs 11:11:25 Integrated Voltage Measurement... 11:11:34 Voltage Offset Correction: v_off_ini = 1046.745 uV, v_off_fin = 1043.391 uV 11:11:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.240 uVs 11:11:38 I1X Average and RMS of Measurements VT = -91.124 +- 15.660 uVs I1X = 18.225 +- 3.133 uTm 11:11:41 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:11:45 Integrated Voltage Measurement... 11:11:54 Voltage Offset Correction: v_off_ini = 1044.909 uV, v_off_fin = 1033.036 uV 11:11:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.504 uVs 11:11:54 Integrated Voltage Measurement... 11:12:03 Voltage Offset Correction: v_off_ini = 1044.798 uV, v_off_fin = 1052.859 uV 11:12:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.160 uVs 11:12:03 Integrated Voltage Measurement... 11:12:12 Voltage Offset Correction: v_off_ini = 1049.135 uV, v_off_fin = 1032.081 uV 11:12:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.186 uVs 11:12:12 Integrated Voltage Measurement... 11:12:21 Voltage Offset Correction: v_off_ini = 1045.658 uV, v_off_fin = 1042.004 uV 11:12:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.133 uVs 11:12:21 Integrated Voltage Measurement... 11:12:30 Voltage Offset Correction: v_off_ini = 1035.749 uV, v_off_fin = 1026.764 uV 11:12:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.020 uVs 11:12:30 Integrated Voltage Measurement... 11:12:39 Voltage Offset Correction: v_off_ini = 1024.004 uV, v_off_fin = 1049.418 uV 11:12:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.911 uVs 11:12:43 I1Y Average and RMS of Measurements VT = -221.319 +- 3.363 uVs I1Y = -44.264 +- 0.673 uTm 11:12:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:12:51 Integrated Voltage Measurement... 11:13:00 Voltage Offset Correction: v_off_ini = 1031.518 uV, v_off_fin = 1029.715 uV 11:13:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.599 uVs 11:13:00 Integrated Voltage Measurement... 11:13:09 Voltage Offset Correction: v_off_ini = 1038.921 uV, v_off_fin = 1051.763 uV 11:13:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.368 uVs 11:13:09 Integrated Voltage Measurement... 11:13:18 Voltage Offset Correction: v_off_ini = 1049.245 uV, v_off_fin = 1030.834 uV 11:13:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.855 uVs 11:13:18 Integrated Voltage Measurement... 11:13:27 Voltage Offset Correction: v_off_ini = 1050.266 uV, v_off_fin = 1063.991 uV 11:13:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.997 uVs 11:13:27 Integrated Voltage Measurement... 11:13:36 Voltage Offset Correction: v_off_ini = 1054.885 uV, v_off_fin = 1053.758 uV 11:13:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.044 uVs 11:13:36 Integrated Voltage Measurement... 11:13:45 Voltage Offset Correction: v_off_ini = 1055.424 uV, v_off_fin = 1057.840 uV 11:13:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.154 uVs 11:13:48 I2X Average and RMS of Measurements VT = -132.170 +- 5.010 uVs I2X = 12.160 +- 0.461 uTm^2 11:13:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:13:56 Integrated Voltage Measurement... 11:14:05 Voltage Offset Correction: v_off_ini = 1040.033 uV, v_off_fin = 1032.404 uV 11:14:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.325 uVs 11:14:05 Integrated Voltage Measurement... 11:14:14 Voltage Offset Correction: v_off_ini = 1048.875 uV, v_off_fin = 1057.826 uV 11:14:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.320 uVs 11:14:14 Integrated Voltage Measurement... 11:14:23 Voltage Offset Correction: v_off_ini = 1060.364 uV, v_off_fin = 1069.128 uV 11:14:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -401.666 uVs 11:14:23 Integrated Voltage Measurement... 11:14:32 Voltage Offset Correction: v_off_ini = 1078.928 uV, v_off_fin = 1072.116 uV 11:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 379.285 uVs 11:14:32 Integrated Voltage Measurement... 11:14:41 Voltage Offset Correction: v_off_ini = 1063.750 uV, v_off_fin = 1055.249 uV 11:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.649 uVs 11:14:41 Integrated Voltage Measurement... 11:14:50 Voltage Offset Correction: v_off_ini = 1063.933 uV, v_off_fin = 1075.813 uV 11:14:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.104 uVs 11:14:52 I2Y Average and RMS of Measurements VT = -385.558 +- 8.295 uVs I2Y = -35.471 +- 0.763 uTm^2 11:14:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:01 Integrated Voltage Measurement... 11:15:10 Voltage Offset Correction: v_off_ini = 1075.645 uV, v_off_fin = 1070.258 uV 11:15:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.720 uVs 11:15:10 Integrated Voltage Measurement... 11:15:19 Voltage Offset Correction: v_off_ini = 1076.919 uV, v_off_fin = 1074.813 uV 11:15:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.977 uVs 11:15:19 Integrated Voltage Measurement... 11:15:28 Voltage Offset Correction: v_off_ini = 1062.866 uV, v_off_fin = 1065.442 uV 11:15:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.397 uVs 11:15:28 Integrated Voltage Measurement... 11:15:37 Voltage Offset Correction: v_off_ini = 1066.662 uV, v_off_fin = 1069.638 uV 11:15:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.915 uVs 11:15:37 Integrated Voltage Measurement... 11:15:46 Voltage Offset Correction: v_off_ini = 1068.528 uV, v_off_fin = 1060.428 uV 11:15:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.799 uVs 11:15:46 Integrated Voltage Measurement... 11:15:55 Voltage Offset Correction: v_off_ini = 1073.153 uV, v_off_fin = 1072.210 uV 11:15:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 102.380 uVs 11:16:00 I1X Average and RMS of Measurements VT = -102.198 +- 0.982 uVs I1X = 20.441 +- 0.197 uTm 11:16:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:16:06 Integrated Voltage Measurement... 11:16:15 Voltage Offset Correction: v_off_ini = 1065.884 uV, v_off_fin = 1039.812 uV 11:16:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.563 uVs 11:16:16 Integrated Voltage Measurement... 11:16:24 Voltage Offset Correction: v_off_ini = 1044.371 uV, v_off_fin = 1060.194 uV 11:16:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.538 uVs 11:16:25 Integrated Voltage Measurement... 11:16:34 Voltage Offset Correction: v_off_ini = 1064.916 uV, v_off_fin = 1050.334 uV 11:16:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.568 uVs 11:16:34 Integrated Voltage Measurement... 11:16:43 Voltage Offset Correction: v_off_ini = 1056.308 uV, v_off_fin = 1062.966 uV 11:16:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.557 uVs 11:16:43 Integrated Voltage Measurement... 11:16:52 Voltage Offset Correction: v_off_ini = 1048.837 uV, v_off_fin = 1049.209 uV 11:16:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.620 uVs 11:16:52 Integrated Voltage Measurement... 11:17:01 Voltage Offset Correction: v_off_ini = 1063.818 uV, v_off_fin = 1069.316 uV 11:17:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.973 uVs 11:17:05 I1Y Average and RMS of Measurements VT = -220.137 +- 4.991 uVs I1Y = -44.027 +- 0.998 uTm 11:17:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:13 Integrated Voltage Measurement... 11:17:22 Voltage Offset Correction: v_off_ini = 1064.085 uV, v_off_fin = 1049.167 uV 11:17:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.487 uVs 11:17:22 Integrated Voltage Measurement... 11:17:31 Voltage Offset Correction: v_off_ini = 1057.176 uV, v_off_fin = 1052.227 uV 11:17:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.570 uVs 11:17:31 Integrated Voltage Measurement... 11:17:40 Voltage Offset Correction: v_off_ini = 1054.963 uV, v_off_fin = 1055.027 uV 11:17:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -131.292 uVs 11:17:40 Integrated Voltage Measurement... 11:17:49 Voltage Offset Correction: v_off_ini = 1067.604 uV, v_off_fin = 1075.348 uV 11:17:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.058 uVs 11:17:49 Integrated Voltage Measurement... 11:17:58 Voltage Offset Correction: v_off_ini = 1045.438 uV, v_off_fin = 1047.037 uV 11:17:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.329 uVs 11:17:58 Integrated Voltage Measurement... 11:18:07 Voltage Offset Correction: v_off_ini = 1055.740 uV, v_off_fin = 1064.419 uV 11:18:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.815 uVs 11:18:09 I2X Average and RMS of Measurements VT = -125.092 +- 2.435 uVs I2X = 11.509 +- 0.223 uTm^2 11:18:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:17 Integrated Voltage Measurement... 11:18:26 Voltage Offset Correction: v_off_ini = 1049.466 uV, v_off_fin = 1035.835 uV 11:18:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.962 uVs 11:18:26 Integrated Voltage Measurement... 11:18:35 Voltage Offset Correction: v_off_ini = 1053.085 uV, v_off_fin = 1040.978 uV 11:18:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 384.978 uVs 11:18:35 Integrated Voltage Measurement... 11:18:44 Voltage Offset Correction: v_off_ini = 1043.245 uV, v_off_fin = 1038.138 uV 11:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -401.230 uVs 11:18:44 Integrated Voltage Measurement... 11:18:53 Voltage Offset Correction: v_off_ini = 1053.920 uV, v_off_fin = 1038.927 uV 11:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.310 uVs 11:18:53 Integrated Voltage Measurement... 11:19:02 Voltage Offset Correction: v_off_ini = 1035.401 uV, v_off_fin = 1040.673 uV 11:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.223 uVs 11:19:02 Integrated Voltage Measurement... 11:19:11 Voltage Offset Correction: v_off_ini = 1046.528 uV, v_off_fin = 1056.904 uV 11:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.937 uVs 11:19:14 I2Y Average and RMS of Measurements VT = -379.773 +- 6.790 uVs I2Y = -34.939 +- 0.625 uTm^2 11:19:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:19:23 Integrated Voltage Measurement... 11:19:32 Voltage Offset Correction: v_off_ini = 1057.132 uV, v_off_fin = 1043.661 uV 11:19:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.638 uVs 11:19:32 Integrated Voltage Measurement... 11:19:41 Voltage Offset Correction: v_off_ini = 1054.543 uV, v_off_fin = 1058.003 uV 11:19:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.042 uVs 11:19:41 Integrated Voltage Measurement... 11:19:50 Voltage Offset Correction: v_off_ini = 1053.352 uV, v_off_fin = 1053.808 uV 11:19:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.931 uVs 11:19:50 Integrated Voltage Measurement... 11:19:59 Voltage Offset Correction: v_off_ini = 1056.140 uV, v_off_fin = 1048.788 uV 11:19:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.063 uVs 11:19:59 Integrated Voltage Measurement... 11:20:08 Voltage Offset Correction: v_off_ini = 1039.220 uV, v_off_fin = 1035.622 uV 11:20:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.550 uVs 11:20:08 Integrated Voltage Measurement... 11:20:17 Voltage Offset Correction: v_off_ini = 1043.184 uV, v_off_fin = 1038.220 uV 11:20:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 102.747 uVs 11:20:21 I1X Average and RMS of Measurements VT = -91.329 +- 2.753 uVs I1X = 18.267 +- 0.551 uTm 11:20:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:20:28 Integrated Voltage Measurement... 11:20:37 Voltage Offset Correction: v_off_ini = 1049.326 uV, v_off_fin = 1049.339 uV 11:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.035 uVs 11:20:37 Integrated Voltage Measurement... 11:20:46 Voltage Offset Correction: v_off_ini = 1055.648 uV, v_off_fin = 1061.856 uV 11:20:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.590 uVs 11:20:46 Integrated Voltage Measurement... 11:20:55 Voltage Offset Correction: v_off_ini = 1065.877 uV, v_off_fin = 1041.987 uV 11:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.768 uVs 11:20:55 Integrated Voltage Measurement... 11:21:04 Voltage Offset Correction: v_off_ini = 1041.886 uV, v_off_fin = 1057.446 uV 11:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.699 uVs 11:21:04 Integrated Voltage Measurement... 11:21:13 Voltage Offset Correction: v_off_ini = 1057.091 uV, v_off_fin = 1043.192 uV 11:21:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.270 uVs 11:21:13 Integrated Voltage Measurement... 11:21:22 Voltage Offset Correction: v_off_ini = 1050.712 uV, v_off_fin = 1068.362 uV 11:21:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.972 uVs 11:21:26 I1Y Average and RMS of Measurements VT = -215.889 +- 6.268 uVs I1Y = -43.178 +- 1.254 uTm 11:21:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:21:34 Integrated Voltage Measurement... 11:21:43 Voltage Offset Correction: v_off_ini = 1049.270 uV, v_off_fin = 1050.001 uV 11:21:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.390 uVs 11:21:43 Integrated Voltage Measurement... 11:21:52 Voltage Offset Correction: v_off_ini = 1059.838 uV, v_off_fin = 1061.013 uV 11:21:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.894 uVs 11:21:52 Integrated Voltage Measurement... 11:22:01 Voltage Offset Correction: v_off_ini = 1056.968 uV, v_off_fin = 1044.981 uV 11:22:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.207 uVs 11:22:01 Integrated Voltage Measurement... 11:22:10 Voltage Offset Correction: v_off_ini = 1061.195 uV, v_off_fin = 1065.928 uV 11:22:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.420 uVs 11:22:10 Integrated Voltage Measurement... 11:22:19 Voltage Offset Correction: v_off_ini = 1057.511 uV, v_off_fin = 1043.210 uV 11:22:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -126.874 uVs 11:22:19 Integrated Voltage Measurement... 11:22:28 Voltage Offset Correction: v_off_ini = 1057.258 uV, v_off_fin = 1059.046 uV 11:22:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.444 uVs 11:22:31 I2X Average and RMS of Measurements VT = -118.372 +- 1.687 uVs I2X = 10.891 +- 0.155 uTm^2 11:22:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:22:38 Integrated Voltage Measurement... 11:22:47 Voltage Offset Correction: v_off_ini = 1047.655 uV, v_off_fin = 1047.526 uV 11:22:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.069 uVs 11:22:47 Integrated Voltage Measurement... 11:22:56 Voltage Offset Correction: v_off_ini = 1068.455 uV, v_off_fin = 1064.163 uV 11:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.283 uVs 11:22:57 Integrated Voltage Measurement... 11:23:05 Voltage Offset Correction: v_off_ini = 1050.215 uV, v_off_fin = 1057.847 uV 11:23:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.268 uVs 11:23:06 Integrated Voltage Measurement... 11:23:15 Voltage Offset Correction: v_off_ini = 1062.879 uV, v_off_fin = 1052.659 uV 11:23:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.788 uVs 11:23:15 Integrated Voltage Measurement... 11:23:24 Voltage Offset Correction: v_off_ini = 1053.744 uV, v_off_fin = 1056.786 uV 11:23:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -366.608 uVs 11:23:24 Integrated Voltage Measurement... 11:23:33 Voltage Offset Correction: v_off_ini = 1048.587 uV, v_off_fin = 1059.655 uV 11:23:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.233 uVs 11:23:35 I2Y Average and RMS of Measurements VT = -371.875 +- 1.342 uVs I2Y = -34.212 +- 0.123 uTm^2 11:23:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:23:44 Integrated Voltage Measurement... 11:23:53 Voltage Offset Correction: v_off_ini = 1067.230 uV, v_off_fin = 1062.925 uV 11:23:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.264 uVs 11:23:53 Integrated Voltage Measurement... 11:24:02 Voltage Offset Correction: v_off_ini = 1060.413 uV, v_off_fin = 1053.203 uV 11:24:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.029 uVs 11:24:02 Integrated Voltage Measurement... 11:24:11 Voltage Offset Correction: v_off_ini = 1062.417 uV, v_off_fin = 1053.999 uV 11:24:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.391 uVs 11:24:11 Integrated Voltage Measurement... 11:24:20 Voltage Offset Correction: v_off_ini = 1055.059 uV, v_off_fin = 1061.778 uV 11:24:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.903 uVs 11:24:20 Integrated Voltage Measurement... 11:24:29 Voltage Offset Correction: v_off_ini = 1063.562 uV, v_off_fin = 1060.440 uV 11:24:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.196 uVs 11:24:29 Integrated Voltage Measurement... 11:24:38 Voltage Offset Correction: v_off_ini = 1049.874 uV, v_off_fin = 1066.424 uV 11:24:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.454 uVs 11:24:42 I1X Average and RMS of Measurements VT = -85.373 +- 4.724 uVs I1X = 17.075 +- 0.945 uTm 11:24:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:24:49 Integrated Voltage Measurement... 11:24:58 Voltage Offset Correction: v_off_ini = 1059.530 uV, v_off_fin = 1051.186 uV 11:24:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.357 uVs 11:24:58 Integrated Voltage Measurement... 11:25:07 Voltage Offset Correction: v_off_ini = 1068.596 uV, v_off_fin = 1059.151 uV 11:25:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.580 uVs 11:25:07 Integrated Voltage Measurement... 11:25:16 Voltage Offset Correction: v_off_ini = 1059.634 uV, v_off_fin = 1048.208 uV 11:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.698 uVs 11:25:16 Integrated Voltage Measurement... 11:25:25 Voltage Offset Correction: v_off_ini = 1060.432 uV, v_off_fin = 1071.513 uV 11:25:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.862 uVs 11:25:25 Integrated Voltage Measurement... 11:25:34 Voltage Offset Correction: v_off_ini = 1044.759 uV, v_off_fin = 1039.147 uV 11:25:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.541 uVs 11:25:34 Integrated Voltage Measurement... 11:25:43 Voltage Offset Correction: v_off_ini = 1051.436 uV, v_off_fin = 1043.697 uV 11:25:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.060 uVs 11:25:47 I1Y Average and RMS of Measurements VT = -210.516 +- 4.358 uVs I1Y = -42.103 +- 0.872 uTm 11:25:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:25:55 Integrated Voltage Measurement... 11:26:04 Voltage Offset Correction: v_off_ini = 1023.977 uV, v_off_fin = 1033.647 uV 11:26:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.549 uVs 11:26:04 Integrated Voltage Measurement... 11:26:13 Voltage Offset Correction: v_off_ini = 1040.528 uV, v_off_fin = 1053.480 uV 11:26:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.140 uVs 11:26:13 Integrated Voltage Measurement... 11:26:22 Voltage Offset Correction: v_off_ini = 1045.699 uV, v_off_fin = 1018.810 uV 11:26:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.691 uVs 11:26:22 Integrated Voltage Measurement... 11:26:31 Voltage Offset Correction: v_off_ini = 1044.755 uV, v_off_fin = 1047.466 uV 11:26:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.328 uVs 11:26:31 Integrated Voltage Measurement... 11:26:40 Voltage Offset Correction: v_off_ini = 1054.631 uV, v_off_fin = 1047.859 uV 11:26:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.374 uVs 11:26:40 Integrated Voltage Measurement... 11:26:49 Voltage Offset Correction: v_off_ini = 1054.450 uV, v_off_fin = 1048.416 uV 11:26:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.823 uVs 11:26:52 I2X Average and RMS of Measurements VT = -110.651 +- 8.162 uVs I2X = 10.180 +- 0.751 uTm^2 11:26:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:27:00 Integrated Voltage Measurement... 11:27:09 Voltage Offset Correction: v_off_ini = 1040.506 uV, v_off_fin = 1044.380 uV 11:27:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.137 uVs 11:27:09 Integrated Voltage Measurement... 11:27:18 Voltage Offset Correction: v_off_ini = 1040.794 uV, v_off_fin = 1051.351 uV 11:27:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.369 uVs 11:27:18 Integrated Voltage Measurement... 11:27:27 Voltage Offset Correction: v_off_ini = 1033.953 uV, v_off_fin = 1033.573 uV 11:27:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -360.960 uVs 11:27:27 Integrated Voltage Measurement... 11:27:36 Voltage Offset Correction: v_off_ini = 1031.700 uV, v_off_fin = 1047.475 uV 11:27:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.390 uVs 11:27:36 Integrated Voltage Measurement... 11:27:45 Voltage Offset Correction: v_off_ini = 1045.428 uV, v_off_fin = 1049.161 uV 11:27:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -359.635 uVs 11:27:45 Integrated Voltage Measurement... 11:27:54 Voltage Offset Correction: v_off_ini = 1041.567 uV, v_off_fin = 1039.166 uV 11:27:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.803 uVs 11:27:56 I2Y Average and RMS of Measurements VT = -366.382 +- 4.140 uVs I2Y = -33.708 +- 0.381 uTm^2 11:28:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:28:08 Integrated Voltage Measurement... 11:28:17 Voltage Offset Correction: v_off_ini = 1047.492 uV, v_off_fin = 1033.404 uV 11:28:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -65.156 uVs 11:28:17 Integrated Voltage Measurement... 11:28:26 Voltage Offset Correction: v_off_ini = 1045.309 uV, v_off_fin = 1049.393 uV 11:28:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.120 uVs 11:28:26 Integrated Voltage Measurement... 11:28:35 Voltage Offset Correction: v_off_ini = 1045.331 uV, v_off_fin = 1041.536 uV 11:28:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.254 uVs 11:28:35 Integrated Voltage Measurement... 11:28:44 Voltage Offset Correction: v_off_ini = 1053.323 uV, v_off_fin = 1040.338 uV 11:28:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.568 uVs 11:28:44 Integrated Voltage Measurement... 11:28:53 Voltage Offset Correction: v_off_ini = 1024.124 uV, v_off_fin = 1023.297 uV 11:28:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.149 uVs 11:28:53 Integrated Voltage Measurement... 11:29:02 Voltage Offset Correction: v_off_ini = 1043.682 uV, v_off_fin = 1029.528 uV 11:29:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.398 uVs 11:29:07 I1X Average and RMS of Measurements VT = -75.774 +- 3.193 uVs I1X = 15.156 +- 0.638 uTm 11:29:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:29:13 Integrated Voltage Measurement... 11:29:22 Voltage Offset Correction: v_off_ini = 1017.790 uV, v_off_fin = 1017.873 uV 11:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.940 uVs 11:29:22 Integrated Voltage Measurement... 11:29:31 Voltage Offset Correction: v_off_ini = 1020.682 uV, v_off_fin = 1037.010 uV 11:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.230 uVs 11:29:31 Integrated Voltage Measurement... 11:29:40 Voltage Offset Correction: v_off_ini = 1032.151 uV, v_off_fin = 1020.161 uV 11:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.754 uVs 11:29:40 Integrated Voltage Measurement... 11:29:49 Voltage Offset Correction: v_off_ini = 1035.048 uV, v_off_fin = 1044.439 uV 11:29:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.577 uVs 11:29:49 Integrated Voltage Measurement... 11:29:58 Voltage Offset Correction: v_off_ini = 1035.291 uV, v_off_fin = 1021.393 uV 11:29:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.646 uVs 11:29:58 Integrated Voltage Measurement... 11:30:07 Voltage Offset Correction: v_off_ini = 1035.370 uV, v_off_fin = 1047.498 uV 11:30:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.796 uVs 11:30:12 I1Y Average and RMS of Measurements VT = -226.824 +- 0.859 uVs I1Y = -45.365 +- 0.172 uTm 11:30:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:30:17 Integrated Voltage Measurement... 11:30:26 Voltage Offset Correction: v_off_ini = 1028.972 uV, v_off_fin = 1031.340 uV 11:30:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.066 uVs 11:30:26 Integrated Voltage Measurement... 11:30:35 Voltage Offset Correction: v_off_ini = 1039.459 uV, v_off_fin = 1056.428 uV 11:30:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.412 uVs 11:30:35 Integrated Voltage Measurement... 11:30:44 Voltage Offset Correction: v_off_ini = 1043.977 uV, v_off_fin = 1039.286 uV 11:30:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.237 uVs 11:30:44 Integrated Voltage Measurement... 11:30:53 Voltage Offset Correction: v_off_ini = 1035.500 uV, v_off_fin = 1042.369 uV 11:30:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.144 uVs 11:30:53 Integrated Voltage Measurement... 11:31:02 Voltage Offset Correction: v_off_ini = 1042.056 uV, v_off_fin = 1019.437 uV 11:31:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.108 uVs 11:31:02 Integrated Voltage Measurement... 11:31:11 Voltage Offset Correction: v_off_ini = 1033.470 uV, v_off_fin = 1036.193 uV 11:31:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.201 uVs 11:31:13 I2X Average and RMS of Measurements VT = -113.861 +- 4.892 uVs I2X = 10.475 +- 0.450 uTm^2 11:31:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:31:19 Integrated Voltage Measurement... 11:31:28 Voltage Offset Correction: v_off_ini = 1038.260 uV, v_off_fin = 1035.345 uV 11:31:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.236 uVs 11:31:28 Integrated Voltage Measurement... 11:31:37 Voltage Offset Correction: v_off_ini = 1040.776 uV, v_off_fin = 1039.849 uV 11:31:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 380.339 uVs 11:31:37 Integrated Voltage Measurement... 11:31:46 Voltage Offset Correction: v_off_ini = 1033.974 uV, v_off_fin = 1035.864 uV 11:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.675 uVs 11:31:46 Integrated Voltage Measurement... 11:31:55 Voltage Offset Correction: v_off_ini = 1038.652 uV, v_off_fin = 1020.766 uV 11:31:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.928 uVs 11:31:55 Integrated Voltage Measurement... 11:32:04 Voltage Offset Correction: v_off_ini = 1033.030 uV, v_off_fin = 1034.651 uV 11:32:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.708 uVs 11:32:04 Integrated Voltage Measurement... 11:32:13 Voltage Offset Correction: v_off_ini = 1034.286 uV, v_off_fin = 1031.634 uV 11:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.519 uVs 11:32:15 I2Y Average and RMS of Measurements VT = -378.067 +- 3.413 uVs I2Y = -34.783 +- 0.314 uTm^2 11:32:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:32:23 Integrated Voltage Measurement... 11:32:32 Voltage Offset Correction: v_off_ini = 1021.627 uV, v_off_fin = 1023.104 uV 11:32:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -89.070 uVs 11:32:33 Integrated Voltage Measurement... 11:32:41 Voltage Offset Correction: v_off_ini = 1018.234 uV, v_off_fin = 1019.188 uV 11:32:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.247 uVs 11:32:42 Integrated Voltage Measurement... 11:32:51 Voltage Offset Correction: v_off_ini = 1020.627 uV, v_off_fin = 1022.821 uV 11:32:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.171 uVs 11:32:51 Integrated Voltage Measurement... 11:33:00 Voltage Offset Correction: v_off_ini = 1023.987 uV, v_off_fin = 1033.230 uV 11:33:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.951 uVs 11:33:00 Integrated Voltage Measurement... 11:33:09 Voltage Offset Correction: v_off_ini = 1040.117 uV, v_off_fin = 1035.070 uV 11:33:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.795 uVs 11:33:09 Integrated Voltage Measurement... 11:33:18 Voltage Offset Correction: v_off_ini = 1033.954 uV, v_off_fin = 1022.438 uV 11:33:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.086 uVs 11:33:22 I1X Average and RMS of Measurements VT = -84.553 +- 2.405 uVs I1X = 16.912 +- 0.480 uTm 11:33:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:33:29 Integrated Voltage Measurement... 11:33:38 Voltage Offset Correction: v_off_ini = 1033.338 uV, v_off_fin = 1023.914 uV 11:33:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.437 uVs 11:33:38 Integrated Voltage Measurement... 11:33:47 Voltage Offset Correction: v_off_ini = 1017.238 uV, v_off_fin = 1041.639 uV 11:33:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.983 uVs 11:33:47 Integrated Voltage Measurement... 11:33:56 Voltage Offset Correction: v_off_ini = 1029.340 uV, v_off_fin = 1023.472 uV 11:33:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.739 uVs 11:33:56 Integrated Voltage Measurement... 11:34:05 Voltage Offset Correction: v_off_ini = 1031.309 uV, v_off_fin = 1028.962 uV 11:34:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.036 uVs 11:34:05 Integrated Voltage Measurement... 11:34:14 Voltage Offset Correction: v_off_ini = 1003.723 uV, v_off_fin = 1010.551 uV 11:34:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.410 uVs 11:34:14 Integrated Voltage Measurement... 11:34:23 Voltage Offset Correction: v_off_ini = 1016.475 uV, v_off_fin = 1032.714 uV 11:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.505 uVs 11:34:27 I1Y Average and RMS of Measurements VT = -221.018 +- 2.806 uVs I1Y = -44.204 +- 0.561 uTm 11:34:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:34:32 Integrated Voltage Measurement... 11:34:41 Voltage Offset Correction: v_off_ini = 1019.754 uV, v_off_fin = 1009.363 uV 11:34:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.899 uVs 11:34:41 Integrated Voltage Measurement... 11:34:50 Voltage Offset Correction: v_off_ini = 1034.402 uV, v_off_fin = 1029.221 uV 11:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.396 uVs 11:34:50 Integrated Voltage Measurement... 11:34:59 Voltage Offset Correction: v_off_ini = 1029.697 uV, v_off_fin = 1027.858 uV 11:34:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -110.768 uVs 11:34:59 Integrated Voltage Measurement... 11:35:08 Voltage Offset Correction: v_off_ini = 1028.092 uV, v_off_fin = 1025.325 uV 11:35:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.805 uVs 11:35:08 Integrated Voltage Measurement... 11:35:17 Voltage Offset Correction: v_off_ini = 1019.982 uV, v_off_fin = 1010.732 uV 11:35:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.839 uVs 11:35:17 Integrated Voltage Measurement... 11:35:26 Voltage Offset Correction: v_off_ini = 1020.496 uV, v_off_fin = 1032.586 uV 11:35:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.888 uVs 11:35:29 I2X Average and RMS of Measurements VT = -107.766 +- 5.432 uVs I2X = 9.915 +- 0.500 uTm^2 11:35:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:35:34 Integrated Voltage Measurement... 11:35:43 Voltage Offset Correction: v_off_ini = 1017.412 uV, v_off_fin = 1021.440 uV 11:35:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.224 uVs 11:35:43 Integrated Voltage Measurement... 11:35:52 Voltage Offset Correction: v_off_ini = 1015.124 uV, v_off_fin = 1018.048 uV 11:35:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.363 uVs 11:35:52 Integrated Voltage Measurement... 11:36:01 Voltage Offset Correction: v_off_ini = 1025.745 uV, v_off_fin = 1023.699 uV 11:36:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.659 uVs 11:36:01 Integrated Voltage Measurement... 11:36:10 Voltage Offset Correction: v_off_ini = 1030.030 uV, v_off_fin = 1025.112 uV 11:36:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 399.117 uVs 11:36:10 Integrated Voltage Measurement... 11:36:19 Voltage Offset Correction: v_off_ini = 1019.369 uV, v_off_fin = 1023.507 uV 11:36:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -386.886 uVs 11:36:19 Integrated Voltage Measurement... 11:36:28 Voltage Offset Correction: v_off_ini = 1007.694 uV, v_off_fin = 1014.505 uV 11:36:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 385.865 uVs 11:36:30 I2Y Average and RMS of Measurements VT = -384.352 +- 7.124 uVs I2Y = -35.360 +- 0.655 uTm^2 11:36:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:36:39 Integrated Voltage Measurement... 11:36:48 Voltage Offset Correction: v_off_ini = 1018.821 uV, v_off_fin = 1016.372 uV 11:36:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.379 uVs 11:36:48 Integrated Voltage Measurement... 11:36:57 Voltage Offset Correction: v_off_ini = 1016.696 uV, v_off_fin = 1021.747 uV 11:36:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.927 uVs 11:36:57 Integrated Voltage Measurement... 11:37:06 Voltage Offset Correction: v_off_ini = 1016.229 uV, v_off_fin = 1016.294 uV 11:37:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.456 uVs 11:37:06 Integrated Voltage Measurement... 11:37:15 Voltage Offset Correction: v_off_ini = 1030.053 uV, v_off_fin = 1022.347 uV 11:37:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.035 uVs 11:37:15 Integrated Voltage Measurement... 11:37:24 Voltage Offset Correction: v_off_ini = 1033.946 uV, v_off_fin = 1024.632 uV 11:37:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.456 uVs 11:37:24 Integrated Voltage Measurement... 11:37:33 Voltage Offset Correction: v_off_ini = 1023.580 uV, v_off_fin = 1034.023 uV 11:37:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.064 uVs 11:37:37 I1X Average and RMS of Measurements VT = -90.220 +- 4.559 uVs I1X = 18.044 +- 0.912 uTm 11:37:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:44 Integrated Voltage Measurement... 11:37:53 Voltage Offset Correction: v_off_ini = 1026.503 uV, v_off_fin = 1005.625 uV 11:37:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.812 uVs 11:37:53 Integrated Voltage Measurement... 11:38:02 Voltage Offset Correction: v_off_ini = 1019.291 uV, v_off_fin = 1016.214 uV 11:38:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.481 uVs 11:38:02 Integrated Voltage Measurement... 11:38:11 Voltage Offset Correction: v_off_ini = 1011.778 uV, v_off_fin = 1011.918 uV 11:38:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.572 uVs 11:38:11 Integrated Voltage Measurement... 11:38:20 Voltage Offset Correction: v_off_ini = 1016.794 uV, v_off_fin = 1024.323 uV 11:38:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.839 uVs 11:38:20 Integrated Voltage Measurement... 11:38:29 Voltage Offset Correction: v_off_ini = 1028.013 uV, v_off_fin = 1010.608 uV 11:38:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.619 uVs 11:38:29 Integrated Voltage Measurement... 11:38:38 Voltage Offset Correction: v_off_ini = 1024.937 uV, v_off_fin = 1023.994 uV 11:38:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.930 uVs 11:38:42 I1Y Average and RMS of Measurements VT = -215.709 +- 2.253 uVs I1Y = -43.142 +- 0.451 uTm 11:38:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:47 Integrated Voltage Measurement... 11:38:56 Voltage Offset Correction: v_off_ini = 1014.977 uV, v_off_fin = 1020.526 uV 11:38:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.721 uVs 11:38:56 Integrated Voltage Measurement... 11:39:05 Voltage Offset Correction: v_off_ini = 1033.557 uV, v_off_fin = 1023.925 uV 11:39:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.101 uVs 11:39:05 Integrated Voltage Measurement... 11:39:14 Voltage Offset Correction: v_off_ini = 1033.772 uV, v_off_fin = 1026.723 uV 11:39:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.280 uVs 11:39:14 Integrated Voltage Measurement... 11:39:23 Voltage Offset Correction: v_off_ini = 1034.916 uV, v_off_fin = 1047.462 uV 11:39:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.954 uVs 11:39:23 Integrated Voltage Measurement... 11:39:32 Voltage Offset Correction: v_off_ini = 1035.382 uV, v_off_fin = 1035.566 uV 11:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.084 uVs 11:39:32 Integrated Voltage Measurement... 11:39:41 Voltage Offset Correction: v_off_ini = 1043.533 uV, v_off_fin = 1047.179 uV 11:39:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 125.352 uVs 11:39:44 I2X Average and RMS of Measurements VT = -124.082 +- 4.646 uVs I2X = 11.416 +- 0.428 uTm^2 11:39:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:49 Integrated Voltage Measurement... 11:39:58 Voltage Offset Correction: v_off_ini = 1038.647 uV, v_off_fin = 1027.371 uV 11:39:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.828 uVs 11:39:58 Integrated Voltage Measurement... 11:40:07 Voltage Offset Correction: v_off_ini = 1036.272 uV, v_off_fin = 1034.100 uV 11:40:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.376 uVs 11:40:07 Integrated Voltage Measurement... 11:40:16 Voltage Offset Correction: v_off_ini = 1039.128 uV, v_off_fin = 1034.990 uV 11:40:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -373.976 uVs 11:40:16 Integrated Voltage Measurement... 11:40:25 Voltage Offset Correction: v_off_ini = 1049.900 uV, v_off_fin = 1052.272 uV 11:40:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.181 uVs 11:40:25 Integrated Voltage Measurement... 11:40:34 Voltage Offset Correction: v_off_ini = 1060.587 uV, v_off_fin = 1049.745 uV 11:40:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.816 uVs 11:40:34 Integrated Voltage Measurement... 11:40:43 Voltage Offset Correction: v_off_ini = 1051.248 uV, v_off_fin = 1057.692 uV 11:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.280 uVs 11:40:46 I2Y Average and RMS of Measurements VT = -378.076 +- 9.786 uVs I2Y = -34.783 +- 0.900 uTm^2 11:40:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:40:54 Integrated Voltage Measurement... 11:41:03 Voltage Offset Correction: v_off_ini = 1050.803 uV, v_off_fin = 1045.091 uV 11:41:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.040 uVs 11:41:03 Integrated Voltage Measurement... 11:41:12 Voltage Offset Correction: v_off_ini = 1043.551 uV, v_off_fin = 1055.208 uV 11:41:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.991 uVs 11:41:12 Integrated Voltage Measurement... 11:41:21 Voltage Offset Correction: v_off_ini = 1049.837 uV, v_off_fin = 1044.271 uV 11:41:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.818 uVs 11:41:21 Integrated Voltage Measurement... 11:41:30 Voltage Offset Correction: v_off_ini = 1052.743 uV, v_off_fin = 1037.834 uV 11:41:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.987 uVs 11:41:30 Integrated Voltage Measurement... 11:41:39 Voltage Offset Correction: v_off_ini = 1035.886 uV, v_off_fin = 1041.465 uV 11:41:39 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -80.264 uVs 11:41:39 Integrated Voltage Measurement... 11:41:48 Voltage Offset Correction: v_off_ini = 1039.545 uV, v_off_fin = 1047.260 uV 11:41:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.088 uVs 11:41:52 I1X Average and RMS of Measurements VT = -78.198 +- 6.927 uVs I1X = 15.641 +- 1.386 uTm 11:41:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:41:59 Integrated Voltage Measurement... 11:42:08 Voltage Offset Correction: v_off_ini = 1041.117 uV, v_off_fin = 1036.493 uV 11:42:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -224.698 uVs 11:42:08 Integrated Voltage Measurement... 11:42:17 Voltage Offset Correction: v_off_ini = 1051.417 uV, v_off_fin = 1055.519 uV 11:42:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.817 uVs 11:42:17 Integrated Voltage Measurement... 11:42:26 Voltage Offset Correction: v_off_ini = 1037.488 uV, v_off_fin = 1030.634 uV 11:42:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.283 uVs 11:42:26 Integrated Voltage Measurement... 11:42:35 Voltage Offset Correction: v_off_ini = 1050.269 uV, v_off_fin = 1057.340 uV 11:42:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.120 uVs 11:42:35 Integrated Voltage Measurement... 11:42:44 Voltage Offset Correction: v_off_ini = 1056.522 uV, v_off_fin = 1040.611 uV 11:42:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.897 uVs 11:42:44 Integrated Voltage Measurement... 11:42:53 Voltage Offset Correction: v_off_ini = 1047.249 uV, v_off_fin = 1061.974 uV 11:42:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.394 uVs 11:42:57 I1Y Average and RMS of Measurements VT = -217.868 +- 7.389 uVs I1Y = -43.575 +- 1.480 uTm 11:43:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:43:02 Integrated Voltage Measurement... 11:43:11 Voltage Offset Correction: v_off_ini = 1041.585 uV, v_off_fin = 1033.355 uV 11:43:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.837 uVs 11:43:11 Integrated Voltage Measurement... 11:43:20 Voltage Offset Correction: v_off_ini = 1044.667 uV, v_off_fin = 1061.315 uV 11:43:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.768 uVs 11:43:20 Integrated Voltage Measurement... 11:43:29 Voltage Offset Correction: v_off_ini = 1042.712 uV, v_off_fin = 1036.793 uV 11:43:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.754 uVs 11:43:29 Integrated Voltage Measurement... 11:43:38 Voltage Offset Correction: v_off_ini = 1046.677 uV, v_off_fin = 1066.287 uV 11:43:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.575 uVs 11:43:38 Integrated Voltage Measurement... 11:43:47 Voltage Offset Correction: v_off_ini = 1054.376 uV, v_off_fin = 1046.751 uV 11:43:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.419 uVs 11:43:47 Integrated Voltage Measurement... 11:43:56 Voltage Offset Correction: v_off_ini = 1067.064 uV, v_off_fin = 1048.564 uV 11:43:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.790 uVs 11:43:59 I2X Average and RMS of Measurements VT = -119.524 +- 7.630 uVs I2X = 10.996 +- 0.702 uTm^2 11:44:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:44:04 Integrated Voltage Measurement... 11:44:13 Voltage Offset Correction: v_off_ini = 1052.252 uV, v_off_fin = 1052.663 uV 11:44:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.905 uVs 11:44:13 Integrated Voltage Measurement... 11:44:22 Voltage Offset Correction: v_off_ini = 1042.919 uV, v_off_fin = 1046.465 uV 11:44:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.495 uVs 11:44:22 Integrated Voltage Measurement... 11:44:31 Voltage Offset Correction: v_off_ini = 1039.273 uV, v_off_fin = 1051.625 uV 11:44:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.489 uVs 11:44:31 Integrated Voltage Measurement... 11:44:40 Voltage Offset Correction: v_off_ini = 1036.098 uV, v_off_fin = 1035.205 uV 11:44:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.697 uVs 11:44:40 Integrated Voltage Measurement... 11:44:49 Voltage Offset Correction: v_off_ini = 1027.917 uV, v_off_fin = 1033.993 uV 11:44:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.749 uVs 11:44:49 Integrated Voltage Measurement... 11:44:58 Voltage Offset Correction: v_off_ini = 1044.977 uV, v_off_fin = 1042.607 uV 11:44:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 386.727 uVs 11:45:00 I2Y Average and RMS of Measurements VT = -379.844 +- 1.136 uVs I2Y = -34.946 +- 0.105 uTm^2 11:45:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:45:09 Integrated Voltage Measurement... 11:45:18 Voltage Offset Correction: v_off_ini = 1039.292 uV, v_off_fin = 1033.921 uV 11:45:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.587 uVs 11:45:18 Integrated Voltage Measurement... 11:45:27 Voltage Offset Correction: v_off_ini = 1051.555 uV, v_off_fin = 1046.734 uV 11:45:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.066 uVs 11:45:27 Integrated Voltage Measurement... 11:45:36 Voltage Offset Correction: v_off_ini = 1044.246 uV, v_off_fin = 1018.282 uV 11:45:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.387 uVs 11:45:36 Integrated Voltage Measurement... 11:45:45 Voltage Offset Correction: v_off_ini = 1015.347 uV, v_off_fin = 1043.037 uV 11:45:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.054 uVs 11:45:45 Integrated Voltage Measurement... 11:45:54 Voltage Offset Correction: v_off_ini = 1042.929 uV, v_off_fin = 1045.111 uV 11:45:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.555 uVs 11:45:54 Integrated Voltage Measurement... 11:46:03 Voltage Offset Correction: v_off_ini = 1040.465 uV, v_off_fin = 1044.946 uV 11:46:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.607 uVs 11:46:07 I1X Average and RMS of Measurements VT = -83.876 +- 8.543 uVs I1X = 16.776 +- 1.708 uTm 11:46:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:46:14 Integrated Voltage Measurement... 11:46:23 Voltage Offset Correction: v_off_ini = 1048.623 uV, v_off_fin = 1024.827 uV 11:46:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.582 uVs 11:46:23 Integrated Voltage Measurement... 11:46:32 Voltage Offset Correction: v_off_ini = 1046.689 uV, v_off_fin = 1063.279 uV 11:46:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.758 uVs 11:46:32 Integrated Voltage Measurement... 11:46:41 Voltage Offset Correction: v_off_ini = 1048.536 uV, v_off_fin = 1035.671 uV 11:46:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.150 uVs 11:46:41 Integrated Voltage Measurement... 11:46:50 Voltage Offset Correction: v_off_ini = 1047.843 uV, v_off_fin = 1062.140 uV 11:46:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.568 uVs 11:46:50 Integrated Voltage Measurement... 11:46:59 Voltage Offset Correction: v_off_ini = 1044.565 uV, v_off_fin = 1026.665 uV 11:46:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.058 uVs 11:46:59 Integrated Voltage Measurement... 11:47:08 Voltage Offset Correction: v_off_ini = 1041.005 uV, v_off_fin = 1048.354 uV 11:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.527 uVs 11:47:12 I1Y Average and RMS of Measurements VT = -212.607 +- 8.082 uVs I1Y = -42.520 +- 1.616 uTm 11:47:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:47:17 Integrated Voltage Measurement... 11:47:26 Voltage Offset Correction: v_off_ini = 1036.913 uV, v_off_fin = 1029.214 uV 11:47:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.861 uVs 11:47:26 Integrated Voltage Measurement... 11:47:35 Voltage Offset Correction: v_off_ini = 1050.093 uV, v_off_fin = 1052.771 uV 11:47:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.096 uVs 11:47:35 Integrated Voltage Measurement... 11:47:44 Voltage Offset Correction: v_off_ini = 1053.223 uV, v_off_fin = 1036.460 uV 11:47:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.905 uVs 11:47:44 Integrated Voltage Measurement... 11:47:53 Voltage Offset Correction: v_off_ini = 1051.273 uV, v_off_fin = 1054.255 uV 11:47:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.839 uVs 11:47:53 Integrated Voltage Measurement... 11:48:02 Voltage Offset Correction: v_off_ini = 1049.555 uV, v_off_fin = 1050.316 uV 11:48:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.660 uVs 11:48:02 Integrated Voltage Measurement... 11:48:11 Voltage Offset Correction: v_off_ini = 1049.724 uV, v_off_fin = 1062.618 uV 11:48:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.161 uVs 11:48:14 I2X Average and RMS of Measurements VT = -129.587 +- 0.847 uVs I2X = 11.922 +- 0.078 uTm^2 11:48:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:48:19 Integrated Voltage Measurement... 11:48:28 Voltage Offset Correction: v_off_ini = 1045.212 uV, v_off_fin = 1051.613 uV 11:48:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.784 uVs 11:48:28 Integrated Voltage Measurement... 11:48:37 Voltage Offset Correction: v_off_ini = 1064.721 uV, v_off_fin = 1055.505 uV 11:48:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.050 uVs 11:48:37 Integrated Voltage Measurement... 11:48:46 Voltage Offset Correction: v_off_ini = 1053.820 uV, v_off_fin = 1052.381 uV 11:48:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.376 uVs 11:48:46 Integrated Voltage Measurement... 11:48:55 Voltage Offset Correction: v_off_ini = 1045.979 uV, v_off_fin = 1045.852 uV 11:48:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.224 uVs 11:48:55 Integrated Voltage Measurement... 11:49:04 Voltage Offset Correction: v_off_ini = 1061.770 uV, v_off_fin = 1045.474 uV 11:49:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -375.198 uVs 11:49:04 Integrated Voltage Measurement... 11:49:13 Voltage Offset Correction: v_off_ini = 1052.114 uV, v_off_fin = 1065.393 uV 11:49:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.835 uVs 11:49:15 I2Y Average and RMS of Measurements VT = -365.245 +- 1.844 uVs I2Y = -33.603 +- 0.170 uTm^2 11:49:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:49:35 Integrated Voltage Measurement... 11:49:44 Voltage Offset Correction: v_off_ini = 1075.015 uV, v_off_fin = 1055.967 uV 11:49:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.886 uVs 11:49:44 Integrated Voltage Measurement... 11:49:53 Voltage Offset Correction: v_off_ini = 1053.942 uV, v_off_fin = 1067.607 uV 11:49:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.872 uVs 11:49:53 Integrated Voltage Measurement... 11:50:02 Voltage Offset Correction: v_off_ini = 1038.398 uV, v_off_fin = 1046.590 uV 11:50:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.412 uVs 11:50:02 Integrated Voltage Measurement... 11:50:11 Voltage Offset Correction: v_off_ini = 1054.246 uV, v_off_fin = 1055.988 uV 11:50:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.583 uVs 11:50:11 Integrated Voltage Measurement... 11:50:20 Voltage Offset Correction: v_off_ini = 1032.176 uV, v_off_fin = 1027.176 uV 11:50:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.452 uVs 11:50:20 Integrated Voltage Measurement... 11:50:29 Voltage Offset Correction: v_off_ini = 1051.243 uV, v_off_fin = 1036.704 uV 11:50:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.503 uVs 11:50:34 I1X Average and RMS of Measurements VT = -95.451 +- 5.287 uVs I1X = 19.090 +- 1.057 uTm 11:50:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:50:40 Integrated Voltage Measurement... 11:50:49 Voltage Offset Correction: v_off_ini = 1019.204 uV, v_off_fin = 1006.518 uV 11:50:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.986 uVs 11:50:49 Integrated Voltage Measurement... 11:50:58 Voltage Offset Correction: v_off_ini = 1031.520 uV, v_off_fin = 1033.729 uV 11:50:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.983 uVs 11:50:58 Integrated Voltage Measurement... 11:51:07 Voltage Offset Correction: v_off_ini = 1027.265 uV, v_off_fin = 1015.134 uV 11:51:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.626 uVs 11:51:07 Integrated Voltage Measurement... 11:51:16 Voltage Offset Correction: v_off_ini = 1019.477 uV, v_off_fin = 1028.327 uV 11:51:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.157 uVs 11:51:16 Integrated Voltage Measurement... 11:51:25 Voltage Offset Correction: v_off_ini = 1026.836 uV, v_off_fin = 1021.156 uV 11:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.799 uVs 11:51:25 Integrated Voltage Measurement... 11:51:34 Voltage Offset Correction: v_off_ini = 1030.851 uV, v_off_fin = 1041.474 uV 11:51:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.841 uVs 11:51:39 I1Y Average and RMS of Measurements VT = -232.232 +- 4.354 uVs I1Y = -46.446 +- 0.871 uTm 11:51:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:51:46 Integrated Voltage Measurement... 11:51:55 Voltage Offset Correction: v_off_ini = 1013.469 uV, v_off_fin = 996.319 uV 11:51:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.632 uVs 11:51:55 Integrated Voltage Measurement... 11:52:04 Voltage Offset Correction: v_off_ini = 1005.824 uV, v_off_fin = 1019.505 uV 11:52:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.099 uVs 11:52:04 Integrated Voltage Measurement... 11:52:13 Voltage Offset Correction: v_off_ini = 1025.163 uV, v_off_fin = 1018.371 uV 11:52:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.107 uVs 11:52:13 Integrated Voltage Measurement... 11:52:22 Voltage Offset Correction: v_off_ini = 1023.920 uV, v_off_fin = 1027.113 uV 11:52:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.241 uVs 11:52:22 Integrated Voltage Measurement... 11:52:31 Voltage Offset Correction: v_off_ini = 1029.990 uV, v_off_fin = 1013.981 uV 11:52:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.731 uVs 11:52:31 Integrated Voltage Measurement... 11:52:40 Voltage Offset Correction: v_off_ini = 1029.297 uV, v_off_fin = 1028.070 uV 11:52:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.350 uVs 11:52:43 I2X Average and RMS of Measurements VT = -120.360 +- 6.260 uVs I2X = 11.073 +- 0.576 uTm^2 11:52:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:52:51 Integrated Voltage Measurement... 11:53:00 Voltage Offset Correction: v_off_ini = 1049.610 uV, v_off_fin = 1039.237 uV 11:53:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.010 uVs 11:53:00 Integrated Voltage Measurement... 11:53:09 Voltage Offset Correction: v_off_ini = 1050.179 uV, v_off_fin = 1050.627 uV 11:53:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 399.757 uVs 11:53:09 Integrated Voltage Measurement... 11:53:18 Voltage Offset Correction: v_off_ini = 1035.601 uV, v_off_fin = 1033.367 uV 11:53:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.337 uVs 11:53:18 Integrated Voltage Measurement... 11:53:27 Voltage Offset Correction: v_off_ini = 1037.163 uV, v_off_fin = 1042.689 uV 11:53:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.202 uVs 11:53:27 Integrated Voltage Measurement... 11:53:36 Voltage Offset Correction: v_off_ini = 1061.041 uV, v_off_fin = 1059.912 uV 11:53:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.314 uVs 11:53:36 Integrated Voltage Measurement... 11:53:45 Voltage Offset Correction: v_off_ini = 1052.155 uV, v_off_fin = 1054.059 uV 11:53:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.974 uVs 11:53:47 I2Y Average and RMS of Measurements VT = -394.432 +- 0.925 uVs I2Y = -36.288 +- 0.085 uTm^2 11:53:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:53:56 Integrated Voltage Measurement... 11:54:05 Voltage Offset Correction: v_off_ini = 1061.673 uV, v_off_fin = 1055.838 uV 11:54:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.384 uVs 11:54:05 Integrated Voltage Measurement... 11:54:14 Voltage Offset Correction: v_off_ini = 1063.483 uV, v_off_fin = 1066.457 uV 11:54:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.278 uVs 11:54:14 Integrated Voltage Measurement... 11:54:23 Voltage Offset Correction: v_off_ini = 1072.271 uV, v_off_fin = 1061.972 uV 11:54:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.940 uVs 11:54:23 Integrated Voltage Measurement... 11:54:32 Voltage Offset Correction: v_off_ini = 1074.220 uV, v_off_fin = 1063.619 uV 11:54:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.030 uVs 11:54:32 Integrated Voltage Measurement... 11:54:41 Voltage Offset Correction: v_off_ini = 1054.660 uV, v_off_fin = 1064.179 uV 11:54:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.903 uVs 11:54:41 Integrated Voltage Measurement... 11:54:50 Voltage Offset Correction: v_off_ini = 1065.755 uV, v_off_fin = 1074.382 uV 11:54:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.227 uVs 11:54:55 I1X Average and RMS of Measurements VT = -88.127 +- 6.159 uVs I1X = 17.626 +- 1.232 uTm 11:54:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:55:01 Integrated Voltage Measurement... 11:55:10 Voltage Offset Correction: v_off_ini = 1064.275 uV, v_off_fin = 1050.809 uV 11:55:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.767 uVs 11:55:10 Integrated Voltage Measurement... 11:55:19 Voltage Offset Correction: v_off_ini = 1065.772 uV, v_off_fin = 1065.282 uV 11:55:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.882 uVs 11:55:19 Integrated Voltage Measurement... 11:55:28 Voltage Offset Correction: v_off_ini = 1063.002 uV, v_off_fin = 1052.728 uV 11:55:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.555 uVs 11:55:28 Integrated Voltage Measurement... 11:55:37 Voltage Offset Correction: v_off_ini = 1056.566 uV, v_off_fin = 1062.108 uV 11:55:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.210 uVs 11:55:37 Integrated Voltage Measurement... 11:55:46 Voltage Offset Correction: v_off_ini = 1048.699 uV, v_off_fin = 1025.881 uV 11:55:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.834 uVs 11:55:46 Integrated Voltage Measurement... 11:55:55 Voltage Offset Correction: v_off_ini = 1048.749 uV, v_off_fin = 1054.939 uV 11:55:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.297 uVs 11:56:00 I1Y Average and RMS of Measurements VT = -224.591 +- 4.480 uVs I1Y = -44.919 +- 0.896 uTm 11:56:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:56:07 Integrated Voltage Measurement... 11:56:16 Voltage Offset Correction: v_off_ini = 1061.059 uV, v_off_fin = 1049.531 uV 11:56:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.073 uVs 11:56:16 Integrated Voltage Measurement... 11:56:25 Voltage Offset Correction: v_off_ini = 1064.800 uV, v_off_fin = 1060.652 uV 11:56:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.324 uVs 11:56:25 Integrated Voltage Measurement... 11:56:34 Voltage Offset Correction: v_off_ini = 1056.350 uV, v_off_fin = 1049.026 uV 11:56:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.737 uVs 11:56:34 Integrated Voltage Measurement... 11:56:43 Voltage Offset Correction: v_off_ini = 1059.879 uV, v_off_fin = 1070.795 uV 11:56:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.046 uVs 11:56:43 Integrated Voltage Measurement... 11:56:52 Voltage Offset Correction: v_off_ini = 1046.413 uV, v_off_fin = 1032.281 uV 11:56:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -112.831 uVs 11:56:52 Integrated Voltage Measurement... 11:57:01 Voltage Offset Correction: v_off_ini = 1025.859 uV, v_off_fin = 1026.256 uV 11:57:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 132.658 uVs 11:57:04 I2X Average and RMS of Measurements VT = -120.778 +- 3.855 uVs I2X = 11.112 +- 0.354 uTm^2 11:57:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:57:12 Integrated Voltage Measurement... 11:57:21 Voltage Offset Correction: v_off_ini = 1037.192 uV, v_off_fin = 1032.003 uV 11:57:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.759 uVs 11:57:21 Integrated Voltage Measurement... 11:57:30 Voltage Offset Correction: v_off_ini = 1038.797 uV, v_off_fin = 1045.867 uV 11:57:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.477 uVs 11:57:30 Integrated Voltage Measurement... 11:57:39 Voltage Offset Correction: v_off_ini = 1040.416 uV, v_off_fin = 1037.342 uV 11:57:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.119 uVs 11:57:39 Integrated Voltage Measurement... 11:57:48 Voltage Offset Correction: v_off_ini = 1021.705 uV, v_off_fin = 1028.655 uV 11:57:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.723 uVs 11:57:48 Integrated Voltage Measurement... 11:57:57 Voltage Offset Correction: v_off_ini = 1015.056 uV, v_off_fin = 1005.018 uV 11:57:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.311 uVs 11:57:57 Integrated Voltage Measurement... 11:58:06 Voltage Offset Correction: v_off_ini = 1001.093 uV, v_off_fin = 1013.032 uV 11:58:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 386.187 uVs 11:58:08 I2Y Average and RMS of Measurements VT = -381.429 +- 4.951 uVs I2Y = -35.091 +- 0.455 uTm^2 11:58:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:17 Integrated Voltage Measurement... 11:58:26 Voltage Offset Correction: v_off_ini = 1016.328 uV, v_off_fin = 1028.984 uV 11:58:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -96.480 uVs 11:58:26 Integrated Voltage Measurement... 11:58:35 Voltage Offset Correction: v_off_ini = 1039.972 uV, v_off_fin = 1049.855 uV 11:58:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.519 uVs 11:58:35 Integrated Voltage Measurement... 11:58:44 Voltage Offset Correction: v_off_ini = 1032.293 uV, v_off_fin = 1032.235 uV 11:58:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.015 uVs 11:58:44 Integrated Voltage Measurement... 11:58:53 Voltage Offset Correction: v_off_ini = 1032.910 uV, v_off_fin = 1025.375 uV 11:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.632 uVs 11:58:53 Integrated Voltage Measurement... 11:59:02 Voltage Offset Correction: v_off_ini = 1024.191 uV, v_off_fin = 1017.464 uV 11:59:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.076 uVs 11:59:02 Integrated Voltage Measurement... 11:59:11 Voltage Offset Correction: v_off_ini = 1017.102 uV, v_off_fin = 1017.786 uV 11:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.253 uVs 11:59:16 I1X Average and RMS of Measurements VT = -95.996 +- 1.771 uVs I1X = 19.200 +- 0.355 uTm 11:59:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:22 Integrated Voltage Measurement... 11:59:31 Voltage Offset Correction: v_off_ini = 1042.953 uV, v_off_fin = 1039.940 uV 11:59:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.948 uVs 11:59:31 Integrated Voltage Measurement... 11:59:40 Voltage Offset Correction: v_off_ini = 1051.930 uV, v_off_fin = 1058.598 uV 11:59:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.212 uVs 11:59:40 Integrated Voltage Measurement... 11:59:49 Voltage Offset Correction: v_off_ini = 1032.841 uV, v_off_fin = 1029.489 uV 11:59:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.916 uVs 11:59:49 Integrated Voltage Measurement... 11:59:58 Voltage Offset Correction: v_off_ini = 1037.604 uV, v_off_fin = 1042.864 uV 11:59:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.379 uVs 11:59:58 Integrated Voltage Measurement... 12:00:07 Voltage Offset Correction: v_off_ini = 1031.405 uV, v_off_fin = 1025.427 uV 12:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.416 uVs 12:00:07 Integrated Voltage Measurement... 12:00:16 Voltage Offset Correction: v_off_ini = 1039.459 uV, v_off_fin = 1059.553 uV 12:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.405 uVs 12:00:21 I1Y Average and RMS of Measurements VT = -213.879 +- 9.533 uVs I1Y = -42.776 +- 1.907 uTm 12:00:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:28 Integrated Voltage Measurement... 12:00:37 Voltage Offset Correction: v_off_ini = 1041.169 uV, v_off_fin = 1033.958 uV 12:00:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.665 uVs 12:00:37 Integrated Voltage Measurement... 12:00:46 Voltage Offset Correction: v_off_ini = 1031.697 uV, v_off_fin = 1044.775 uV 12:00:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.557 uVs 12:00:46 Integrated Voltage Measurement... 12:00:55 Voltage Offset Correction: v_off_ini = 1041.631 uV, v_off_fin = 1025.134 uV 12:00:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.841 uVs 12:00:55 Integrated Voltage Measurement... 12:01:04 Voltage Offset Correction: v_off_ini = 1043.874 uV, v_off_fin = 1043.405 uV 12:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.555 uVs 12:01:04 Integrated Voltage Measurement... 12:01:13 Voltage Offset Correction: v_off_ini = 1047.484 uV, v_off_fin = 1024.509 uV 12:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.526 uVs 12:01:13 Integrated Voltage Measurement... 12:01:22 Voltage Offset Correction: v_off_ini = 1048.675 uV, v_off_fin = 1047.435 uV 12:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.129 uVs 12:01:25 I2X Average and RMS of Measurements VT = -118.712 +- 8.353 uVs I2X = 10.922 +- 0.768 uTm^2 12:01:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:33 Integrated Voltage Measurement... 12:01:42 Voltage Offset Correction: v_off_ini = 1046.390 uV, v_off_fin = 1048.918 uV 12:01:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -388.278 uVs 12:01:42 Integrated Voltage Measurement... 12:01:51 Voltage Offset Correction: v_off_ini = 1044.432 uV, v_off_fin = 1048.753 uV 12:01:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.515 uVs 12:01:51 Integrated Voltage Measurement... 12:02:00 Voltage Offset Correction: v_off_ini = 1045.825 uV, v_off_fin = 1040.362 uV 12:02:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -363.784 uVs 12:02:00 Integrated Voltage Measurement... 12:02:09 Voltage Offset Correction: v_off_ini = 1038.998 uV, v_off_fin = 1033.070 uV 12:02:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.672 uVs 12:02:09 Integrated Voltage Measurement... 12:02:18 Voltage Offset Correction: v_off_ini = 1032.025 uV, v_off_fin = 1040.540 uV 12:02:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.142 uVs 12:02:18 Integrated Voltage Measurement... 12:02:27 Voltage Offset Correction: v_off_ini = 1031.190 uV, v_off_fin = 1031.063 uV 12:02:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.087 uVs 12:02:29 I2Y Average and RMS of Measurements VT = -371.246 +- 7.599 uVs I2Y = -34.155 +- 0.699 uTm^2 12:02:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:02:38 Integrated Voltage Measurement... 12:02:47 Voltage Offset Correction: v_off_ini = 1022.835 uV, v_off_fin = 1018.010 uV 12:02:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.280 uVs 12:02:47 Integrated Voltage Measurement... 12:02:56 Voltage Offset Correction: v_off_ini = 1032.895 uV, v_off_fin = 1017.617 uV 12:02:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.965 uVs 12:02:56 Integrated Voltage Measurement... 12:03:05 Voltage Offset Correction: v_off_ini = 1026.343 uV, v_off_fin = 1016.232 uV 12:03:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.439 uVs 12:03:05 Integrated Voltage Measurement... 12:03:14 Voltage Offset Correction: v_off_ini = 1022.686 uV, v_off_fin = 1037.829 uV 12:03:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.897 uVs 12:03:14 Integrated Voltage Measurement... 12:03:23 Voltage Offset Correction: v_off_ini = 1022.426 uV, v_off_fin = 1022.543 uV 12:03:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.412 uVs 12:03:23 Integrated Voltage Measurement... 12:03:32 Voltage Offset Correction: v_off_ini = 1036.109 uV, v_off_fin = 1040.006 uV 12:03:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.263 uVs 12:03:37 I1X Average and RMS of Measurements VT = -74.209 +- 6.083 uVs I1X = 14.842 +- 1.217 uTm 12:03:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:03:43 Integrated Voltage Measurement... 12:03:52 Voltage Offset Correction: v_off_ini = 1043.762 uV, v_off_fin = 1036.111 uV 12:03:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -219.415 uVs 12:03:52 Integrated Voltage Measurement... 12:04:01 Voltage Offset Correction: v_off_ini = 1043.328 uV, v_off_fin = 1064.381 uV 12:04:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.594 uVs 12:04:01 Integrated Voltage Measurement... 12:04:10 Voltage Offset Correction: v_off_ini = 1063.471 uV, v_off_fin = 1049.566 uV 12:04:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.620 uVs 12:04:10 Integrated Voltage Measurement... 12:04:19 Voltage Offset Correction: v_off_ini = 1053.013 uV, v_off_fin = 1060.621 uV 12:04:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.523 uVs 12:04:20 Integrated Voltage Measurement... 12:04:28 Voltage Offset Correction: v_off_ini = 1053.193 uV, v_off_fin = 1039.274 uV 12:04:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.798 uVs 12:04:29 Integrated Voltage Measurement... 12:04:37 Voltage Offset Correction: v_off_ini = 1052.127 uV, v_off_fin = 1054.086 uV 12:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.792 uVs 12:04:42 I1Y Average and RMS of Measurements VT = -213.790 +- 2.791 uVs I1Y = -42.759 +- 0.558 uTm 12:04:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:04:49 Integrated Voltage Measurement... 12:04:58 Voltage Offset Correction: v_off_ini = 1037.539 uV, v_off_fin = 1028.215 uV 12:04:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.871 uVs 12:04:58 Integrated Voltage Measurement... 12:05:07 Voltage Offset Correction: v_off_ini = 1046.754 uV, v_off_fin = 1060.082 uV 12:05:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.044 uVs 12:05:08 Integrated Voltage Measurement... 12:05:17 Voltage Offset Correction: v_off_ini = 1051.975 uV, v_off_fin = 1044.397 uV 12:05:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.674 uVs 12:05:17 Integrated Voltage Measurement... 12:05:26 Voltage Offset Correction: v_off_ini = 1056.634 uV, v_off_fin = 1059.788 uV 12:05:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.028 uVs 12:05:26 Integrated Voltage Measurement... 12:05:35 Voltage Offset Correction: v_off_ini = 1045.857 uV, v_off_fin = 1033.711 uV 12:05:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.985 uVs 12:05:35 Integrated Voltage Measurement... 12:05:44 Voltage Offset Correction: v_off_ini = 1041.755 uV, v_off_fin = 1060.671 uV 12:05:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.642 uVs 12:05:46 I2X Average and RMS of Measurements VT = -105.707 +- 6.999 uVs I2X = 9.725 +- 0.644 uTm^2 12:05:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:05:54 Integrated Voltage Measurement... 12:06:03 Voltage Offset Correction: v_off_ini = 1029.906 uV, v_off_fin = 1036.144 uV 12:06:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.329 uVs 12:06:03 Integrated Voltage Measurement... 12:06:12 Voltage Offset Correction: v_off_ini = 1042.741 uV, v_off_fin = 1054.792 uV 12:06:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.689 uVs 12:06:12 Integrated Voltage Measurement... 12:06:21 Voltage Offset Correction: v_off_ini = 1052.823 uV, v_off_fin = 1048.937 uV 12:06:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -373.947 uVs 12:06:21 Integrated Voltage Measurement... 12:06:30 Voltage Offset Correction: v_off_ini = 1053.260 uV, v_off_fin = 1063.716 uV 12:06:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.281 uVs 12:06:30 Integrated Voltage Measurement... 12:06:39 Voltage Offset Correction: v_off_ini = 1064.315 uV, v_off_fin = 1059.420 uV 12:06:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.469 uVs 12:06:39 Integrated Voltage Measurement... 12:06:48 Voltage Offset Correction: v_off_ini = 1070.311 uV, v_off_fin = 1069.930 uV 12:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.634 uVs 12:06:51 I2Y Average and RMS of Measurements VT = -362.892 +- 6.614 uVs I2Y = -33.387 +- 0.609 uTm^2 12:06:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:06:59 Integrated Voltage Measurement... 12:07:08 Voltage Offset Correction: v_off_ini = 1051.861 uV, v_off_fin = 1050.489 uV 12:07:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.192 uVs 12:07:09 Integrated Voltage Measurement... 12:07:17 Voltage Offset Correction: v_off_ini = 1047.002 uV, v_off_fin = 1061.887 uV 12:07:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.268 uVs 12:07:18 Integrated Voltage Measurement... 12:07:27 Voltage Offset Correction: v_off_ini = 1049.909 uV, v_off_fin = 1052.903 uV 12:07:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.958 uVs 12:07:27 Integrated Voltage Measurement... 12:07:36 Voltage Offset Correction: v_off_ini = 1056.735 uV, v_off_fin = 1052.323 uV 12:07:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.810 uVs 12:07:36 Integrated Voltage Measurement... 12:07:45 Voltage Offset Correction: v_off_ini = 1053.511 uV, v_off_fin = 1056.275 uV 12:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.071 uVs 12:07:45 Integrated Voltage Measurement... 12:07:54 Voltage Offset Correction: v_off_ini = 1047.758 uV, v_off_fin = 1052.512 uV 12:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.207 uVs 12:07:58 I1X Average and RMS of Measurements VT = -76.251 +- 8.148 uVs I1X = 15.250 +- 1.630 uTm 12:08:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:08:05 Integrated Voltage Measurement... 12:08:14 Voltage Offset Correction: v_off_ini = 1045.467 uV, v_off_fin = 1046.676 uV 12:08:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.941 uVs 12:08:14 Integrated Voltage Measurement... 12:08:23 Voltage Offset Correction: v_off_ini = 1051.052 uV, v_off_fin = 1056.484 uV 12:08:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.810 uVs 12:08:23 Integrated Voltage Measurement... 12:08:32 Voltage Offset Correction: v_off_ini = 1046.433 uV, v_off_fin = 1029.636 uV 12:08:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.839 uVs 12:08:32 Integrated Voltage Measurement... 12:08:41 Voltage Offset Correction: v_off_ini = 1046.105 uV, v_off_fin = 1053.607 uV 12:08:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.073 uVs 12:08:41 Integrated Voltage Measurement... 12:08:50 Voltage Offset Correction: v_off_ini = 1036.545 uV, v_off_fin = 1038.608 uV 12:08:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.620 uVs 12:08:50 Integrated Voltage Measurement... 12:08:59 Voltage Offset Correction: v_off_ini = 1031.646 uV, v_off_fin = 1054.671 uV 12:08:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.597 uVs 12:09:03 I1Y Average and RMS of Measurements VT = -211.480 +- 8.844 uVs I1Y = -42.296 +- 1.769 uTm 12:09:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:09:11 Integrated Voltage Measurement... 12:09:20 Voltage Offset Correction: v_off_ini = 1025.404 uV, v_off_fin = 1028.430 uV 12:09:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.449 uVs 12:09:20 Integrated Voltage Measurement... 12:09:29 Voltage Offset Correction: v_off_ini = 1046.111 uV, v_off_fin = 1060.539 uV 12:09:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.884 uVs 12:09:29 Integrated Voltage Measurement... 12:09:38 Voltage Offset Correction: v_off_ini = 1048.516 uV, v_off_fin = 1040.447 uV 12:09:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.778 uVs 12:09:38 Integrated Voltage Measurement... 12:09:47 Voltage Offset Correction: v_off_ini = 1048.971 uV, v_off_fin = 1050.055 uV 12:09:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.912 uVs 12:09:47 Integrated Voltage Measurement... 12:09:56 Voltage Offset Correction: v_off_ini = 1056.364 uV, v_off_fin = 1040.452 uV 12:09:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.957 uVs 12:09:56 Integrated Voltage Measurement... 12:10:05 Voltage Offset Correction: v_off_ini = 1034.775 uV, v_off_fin = 1037.291 uV 12:10:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.424 uVs 12:10:07 I2X Average and RMS of Measurements VT = -114.067 +- 9.846 uVs I2X = 10.495 +- 0.906 uTm^2 12:10:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:10:15 Integrated Voltage Measurement... 12:10:24 Voltage Offset Correction: v_off_ini = 1030.995 uV, v_off_fin = 1037.095 uV 12:10:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.455 uVs 12:10:24 Integrated Voltage Measurement... 12:10:33 Voltage Offset Correction: v_off_ini = 1038.560 uV, v_off_fin = 1046.605 uV 12:10:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.755 uVs 12:10:33 Integrated Voltage Measurement... 12:10:42 Voltage Offset Correction: v_off_ini = 1049.230 uV, v_off_fin = 1044.412 uV 12:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.496 uVs 12:10:42 Integrated Voltage Measurement... 12:10:51 Voltage Offset Correction: v_off_ini = 1043.480 uV, v_off_fin = 1038.199 uV 12:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.217 uVs 12:10:51 Integrated Voltage Measurement... 12:11:00 Voltage Offset Correction: v_off_ini = 1049.285 uV, v_off_fin = 1050.404 uV 12:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.536 uVs 12:11:00 Integrated Voltage Measurement... 12:11:09 Voltage Offset Correction: v_off_ini = 1050.758 uV, v_off_fin = 1052.192 uV 12:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.990 uVs 12:11:12 I2Y Average and RMS of Measurements VT = -361.075 +- 4.228 uVs I2Y = -33.219 +- 0.389 uTm^2 12:11:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:11:24 Integrated Voltage Measurement... 12:11:33 Voltage Offset Correction: v_off_ini = 1041.407 uV, v_off_fin = 1036.654 uV 12:11:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.018 uVs 12:11:33 Integrated Voltage Measurement... 12:11:42 Voltage Offset Correction: v_off_ini = 1042.597 uV, v_off_fin = 1042.245 uV 12:11:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.666 uVs 12:11:42 Integrated Voltage Measurement... 12:11:51 Voltage Offset Correction: v_off_ini = 1035.595 uV, v_off_fin = 1030.567 uV 12:11:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.653 uVs 12:11:51 Integrated Voltage Measurement... 12:12:00 Voltage Offset Correction: v_off_ini = 1043.072 uV, v_off_fin = 1035.527 uV 12:12:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 78.973 uVs 12:12:00 Integrated Voltage Measurement... 12:12:09 Voltage Offset Correction: v_off_ini = 1048.494 uV, v_off_fin = 1038.566 uV 12:12:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.138 uVs 12:12:09 Integrated Voltage Measurement... 12:12:18 Voltage Offset Correction: v_off_ini = 1025.480 uV, v_off_fin = 1041.929 uV 12:12:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 77.007 uVs 12:12:22 I1X Average and RMS of Measurements VT = -77.242 +- 2.676 uVs I1X = 15.449 +- 0.534 uTm 12:12:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:12:29 Integrated Voltage Measurement... 12:12:38 Voltage Offset Correction: v_off_ini = 1037.962 uV, v_off_fin = 1027.207 uV 12:12:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.338 uVs 12:12:38 Integrated Voltage Measurement... 12:12:47 Voltage Offset Correction: v_off_ini = 1048.030 uV, v_off_fin = 1054.000 uV 12:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 211.439 uVs 12:12:47 Integrated Voltage Measurement... 12:12:56 Voltage Offset Correction: v_off_ini = 1032.509 uV, v_off_fin = 1026.303 uV 12:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.742 uVs 12:12:56 Integrated Voltage Measurement... 12:13:05 Voltage Offset Correction: v_off_ini = 1038.949 uV, v_off_fin = 1047.184 uV 12:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.948 uVs 12:13:05 Integrated Voltage Measurement... 12:13:14 Voltage Offset Correction: v_off_ini = 1046.605 uV, v_off_fin = 1029.353 uV 12:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.583 uVs 12:13:14 Integrated Voltage Measurement... 12:13:23 Voltage Offset Correction: v_off_ini = 1048.169 uV, v_off_fin = 1045.724 uV 12:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.352 uVs 12:13:27 I1Y Average and RMS of Measurements VT = -216.900 +- 2.595 uVs I1Y = -43.381 +- 0.519 uTm 12:13:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:13:32 Integrated Voltage Measurement... 12:13:41 Voltage Offset Correction: v_off_ini = 1050.899 uV, v_off_fin = 1040.382 uV 12:13:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.398 uVs 12:13:41 Integrated Voltage Measurement... 12:13:50 Voltage Offset Correction: v_off_ini = 1058.774 uV, v_off_fin = 1066.584 uV 12:13:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.911 uVs 12:13:50 Integrated Voltage Measurement... 12:13:59 Voltage Offset Correction: v_off_ini = 1043.809 uV, v_off_fin = 1034.634 uV 12:13:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.614 uVs 12:13:59 Integrated Voltage Measurement... 12:14:08 Voltage Offset Correction: v_off_ini = 1048.123 uV, v_off_fin = 1063.228 uV 12:14:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.041 uVs 12:14:09 Integrated Voltage Measurement... 12:14:18 Voltage Offset Correction: v_off_ini = 1051.632 uV, v_off_fin = 1038.850 uV 12:14:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.198 uVs 12:14:18 Integrated Voltage Measurement... 12:14:27 Voltage Offset Correction: v_off_ini = 1053.653 uV, v_off_fin = 1063.292 uV 12:14:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.119 uVs 12:14:29 I2X Average and RMS of Measurements VT = -105.047 +- 4.571 uVs I2X = 9.664 +- 0.421 uTm^2 12:14:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:14:34 Integrated Voltage Measurement... 12:14:43 Voltage Offset Correction: v_off_ini = 1054.021 uV, v_off_fin = 1050.557 uV 12:14:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.489 uVs 12:14:43 Integrated Voltage Measurement... 12:14:52 Voltage Offset Correction: v_off_ini = 1044.239 uV, v_off_fin = 1052.976 uV 12:14:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.515 uVs 12:14:52 Integrated Voltage Measurement... 12:15:01 Voltage Offset Correction: v_off_ini = 1048.764 uV, v_off_fin = 1053.433 uV 12:15:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.781 uVs 12:15:01 Integrated Voltage Measurement... 12:15:10 Voltage Offset Correction: v_off_ini = 1041.776 uV, v_off_fin = 1037.288 uV 12:15:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.005 uVs 12:15:10 Integrated Voltage Measurement... 12:15:19 Voltage Offset Correction: v_off_ini = 1051.753 uV, v_off_fin = 1044.309 uV 12:15:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.342 uVs 12:15:19 Integrated Voltage Measurement... 12:15:28 Voltage Offset Correction: v_off_ini = 1063.625 uV, v_off_fin = 1054.224 uV 12:15:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.787 uVs 12:15:31 I2Y Average and RMS of Measurements VT = -381.653 +- 9.853 uVs I2Y = -35.112 +- 0.907 uTm^2 12:15:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:15:39 Integrated Voltage Measurement... 12:15:48 Voltage Offset Correction: v_off_ini = 1053.524 uV, v_off_fin = 1033.268 uV 12:15:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.199 uVs 12:15:48 Integrated Voltage Measurement... 12:15:57 Voltage Offset Correction: v_off_ini = 1034.570 uV, v_off_fin = 1043.123 uV 12:15:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.567 uVs 12:15:57 Integrated Voltage Measurement... 12:16:06 Voltage Offset Correction: v_off_ini = 1040.550 uV, v_off_fin = 1040.011 uV 12:16:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.511 uVs 12:16:06 Integrated Voltage Measurement... 12:16:15 Voltage Offset Correction: v_off_ini = 1047.768 uV, v_off_fin = 1049.873 uV 12:16:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.396 uVs 12:16:15 Integrated Voltage Measurement... 12:16:24 Voltage Offset Correction: v_off_ini = 1035.510 uV, v_off_fin = 1042.123 uV 12:16:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.134 uVs 12:16:24 Integrated Voltage Measurement... 12:16:33 Voltage Offset Correction: v_off_ini = 1047.162 uV, v_off_fin = 1042.769 uV 12:16:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.203 uVs 12:16:37 I1X Average and RMS of Measurements VT = -76.002 +- 3.960 uVs I1X = 15.201 +- 0.792 uTm 12:16:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:16:44 Integrated Voltage Measurement... 12:16:53 Voltage Offset Correction: v_off_ini = 1041.128 uV, v_off_fin = 1030.263 uV 12:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.418 uVs 12:16:53 Integrated Voltage Measurement... 12:17:02 Voltage Offset Correction: v_off_ini = 1034.113 uV, v_off_fin = 1046.595 uV 12:17:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 224.138 uVs 12:17:02 Integrated Voltage Measurement... 12:17:11 Voltage Offset Correction: v_off_ini = 1038.138 uV, v_off_fin = 1032.406 uV 12:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.059 uVs 12:17:11 Integrated Voltage Measurement... 12:17:20 Voltage Offset Correction: v_off_ini = 1050.305 uV, v_off_fin = 1064.618 uV 12:17:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.347 uVs 12:17:20 Integrated Voltage Measurement... 12:17:29 Voltage Offset Correction: v_off_ini = 1056.024 uV, v_off_fin = 1037.768 uV 12:17:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.102 uVs 12:17:29 Integrated Voltage Measurement... 12:17:38 Voltage Offset Correction: v_off_ini = 1051.280 uV, v_off_fin = 1056.236 uV 12:17:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.122 uVs 12:17:42 I1Y Average and RMS of Measurements VT = -216.031 +- 2.832 uVs I1Y = -43.208 +- 0.567 uTm 12:17:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:17:48 Integrated Voltage Measurement... 12:17:57 Voltage Offset Correction: v_off_ini = 1054.320 uV, v_off_fin = 1036.517 uV 12:17:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.685 uVs 12:17:57 Integrated Voltage Measurement... 12:18:06 Voltage Offset Correction: v_off_ini = 1046.096 uV, v_off_fin = 1059.290 uV 12:18:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.810 uVs 12:18:06 Integrated Voltage Measurement... 12:18:15 Voltage Offset Correction: v_off_ini = 1053.397 uV, v_off_fin = 1042.471 uV 12:18:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.124 uVs 12:18:15 Integrated Voltage Measurement... 12:18:24 Voltage Offset Correction: v_off_ini = 1038.233 uV, v_off_fin = 1050.105 uV 12:18:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.494 uVs 12:18:24 Integrated Voltage Measurement... 12:18:33 Voltage Offset Correction: v_off_ini = 1031.290 uV, v_off_fin = 1033.151 uV 12:18:33 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -93.986 uVs 12:18:33 Integrated Voltage Measurement... 12:18:42 Voltage Offset Correction: v_off_ini = 1036.402 uV, v_off_fin = 1053.289 uV 12:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.527 uVs 12:18:45 I2X Average and RMS of Measurements VT = -113.438 +- 5.351 uVs I2X = 10.437 +- 0.492 uTm^2 12:18:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:18:50 Integrated Voltage Measurement... 12:18:59 Voltage Offset Correction: v_off_ini = 1044.817 uV, v_off_fin = 1039.368 uV 12:18:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.795 uVs 12:18:59 Integrated Voltage Measurement... 12:19:08 Voltage Offset Correction: v_off_ini = 1041.276 uV, v_off_fin = 1041.980 uV 12:19:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.870 uVs 12:19:08 Integrated Voltage Measurement... 12:19:17 Voltage Offset Correction: v_off_ini = 1034.517 uV, v_off_fin = 1036.460 uV 12:19:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.131 uVs 12:19:17 Integrated Voltage Measurement... 12:19:26 Voltage Offset Correction: v_off_ini = 1040.240 uV, v_off_fin = 1029.464 uV 12:19:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.867 uVs 12:19:26 Integrated Voltage Measurement... 12:19:35 Voltage Offset Correction: v_off_ini = 1027.863 uV, v_off_fin = 1014.603 uV 12:19:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.011 uVs 12:19:35 Integrated Voltage Measurement... 12:19:44 Voltage Offset Correction: v_off_ini = 1024.797 uV, v_off_fin = 1020.816 uV 12:19:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.145 uVs 12:19:46 I2Y Average and RMS of Measurements VT = -373.637 +- 5.824 uVs I2Y = -34.375 +- 0.536 uTm^2 12:19:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:55 Integrated Voltage Measurement... 12:20:04 Voltage Offset Correction: v_off_ini = 1024.909 uV, v_off_fin = 1017.237 uV 12:20:04 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -77.255 uVs 12:20:04 Integrated Voltage Measurement... 12:20:13 Voltage Offset Correction: v_off_ini = 1033.067 uV, v_off_fin = 1021.810 uV 12:20:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 96.047 uVs 12:20:13 Integrated Voltage Measurement... 12:20:22 Voltage Offset Correction: v_off_ini = 1016.790 uV, v_off_fin = 1013.825 uV 12:20:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.181 uVs 12:20:22 Integrated Voltage Measurement... 12:20:31 Voltage Offset Correction: v_off_ini = 1021.430 uV, v_off_fin = 1016.980 uV 12:20:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.714 uVs 12:20:31 Integrated Voltage Measurement... 12:20:40 Voltage Offset Correction: v_off_ini = 1031.085 uV, v_off_fin = 1015.522 uV 12:20:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.423 uVs 12:20:40 Integrated Voltage Measurement... 12:20:49 Voltage Offset Correction: v_off_ini = 1014.478 uV, v_off_fin = 1021.369 uV 12:20:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.912 uVs 12:20:53 I1X Average and RMS of Measurements VT = -90.589 +- 2.786 uVs I1X = 18.119 +- 0.555 uTm 12:20:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:00 Integrated Voltage Measurement... 12:21:09 Voltage Offset Correction: v_off_ini = 1022.191 uV, v_off_fin = 1006.667 uV 12:21:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.099 uVs 12:21:09 Integrated Voltage Measurement... 12:21:18 Voltage Offset Correction: v_off_ini = 1008.756 uV, v_off_fin = 1020.601 uV 12:21:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.041 uVs 12:21:18 Integrated Voltage Measurement... 12:21:27 Voltage Offset Correction: v_off_ini = 1026.611 uV, v_off_fin = 1007.416 uV 12:21:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.641 uVs 12:21:27 Integrated Voltage Measurement... 12:21:36 Voltage Offset Correction: v_off_ini = 1010.158 uV, v_off_fin = 1025.016 uV 12:21:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.404 uVs 12:21:36 Integrated Voltage Measurement... 12:21:45 Voltage Offset Correction: v_off_ini = 1004.814 uV, v_off_fin = 1003.241 uV 12:21:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.636 uVs 12:21:45 Integrated Voltage Measurement... 12:21:54 Voltage Offset Correction: v_off_ini = 1008.412 uV, v_off_fin = 1014.857 uV 12:21:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.702 uVs 12:21:58 I1Y Average and RMS of Measurements VT = -220.587 +- 5.363 uVs I1Y = -44.117 +- 1.073 uTm 12:22:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:03 Integrated Voltage Measurement... 12:22:12 Voltage Offset Correction: v_off_ini = 1004.684 uV, v_off_fin = 1002.666 uV 12:22:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.345 uVs 12:22:12 Integrated Voltage Measurement... 12:22:21 Voltage Offset Correction: v_off_ini = 1013.583 uV, v_off_fin = 1007.857 uV 12:22:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.722 uVs 12:22:21 Integrated Voltage Measurement... 12:22:30 Voltage Offset Correction: v_off_ini = 988.874 uV, v_off_fin = 984.938 uV 12:22:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.357 uVs 12:22:30 Integrated Voltage Measurement... 12:22:39 Voltage Offset Correction: v_off_ini = 1003.624 uV, v_off_fin = 1003.982 uV 12:22:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.540 uVs 12:22:39 Integrated Voltage Measurement... 12:22:48 Voltage Offset Correction: v_off_ini = 998.644 uV, v_off_fin = 987.258 uV 12:22:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.285 uVs 12:22:48 Integrated Voltage Measurement... 12:22:57 Voltage Offset Correction: v_off_ini = 986.497 uV, v_off_fin = 1001.229 uV 12:22:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.553 uVs 12:23:00 I2X Average and RMS of Measurements VT = -122.134 +- 3.253 uVs I2X = 11.236 +- 0.299 uTm^2 12:23:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:23:05 Integrated Voltage Measurement... 12:23:14 Voltage Offset Correction: v_off_ini = 984.567 uV, v_off_fin = 994.488 uV 12:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.377 uVs 12:23:14 Integrated Voltage Measurement... 12:23:23 Voltage Offset Correction: v_off_ini = 1003.970 uV, v_off_fin = 995.606 uV 12:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.996 uVs 12:23:23 Integrated Voltage Measurement... 12:23:32 Voltage Offset Correction: v_off_ini = 1004.224 uV, v_off_fin = 994.225 uV 12:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.368 uVs 12:23:32 Integrated Voltage Measurement... 12:23:41 Voltage Offset Correction: v_off_ini = 980.223 uV, v_off_fin = 994.489 uV 12:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.013 uVs 12:23:41 Integrated Voltage Measurement... 12:23:50 Voltage Offset Correction: v_off_ini = 992.235 uV, v_off_fin = 994.384 uV 12:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.552 uVs 12:23:50 Integrated Voltage Measurement... 12:23:59 Voltage Offset Correction: v_off_ini = 988.050 uV, v_off_fin = 985.887 uV 12:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.382 uVs 12:24:02 I2Y Average and RMS of Measurements VT = -376.115 +- 5.412 uVs I2Y = -34.603 +- 0.498 uTm^2 12:24:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:24:10 Integrated Voltage Measurement... 12:24:19 Voltage Offset Correction: v_off_ini = 993.262 uV, v_off_fin = 987.293 uV 12:24:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -104.191 uVs 12:24:19 Integrated Voltage Measurement... 12:24:28 Voltage Offset Correction: v_off_ini = 1003.394 uV, v_off_fin = 992.085 uV 12:24:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.497 uVs 12:24:28 Integrated Voltage Measurement... 12:24:37 Voltage Offset Correction: v_off_ini = 988.843 uV, v_off_fin = 981.188 uV 12:24:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.135 uVs 12:24:37 Integrated Voltage Measurement... 12:24:46 Voltage Offset Correction: v_off_ini = 994.450 uV, v_off_fin = 1012.885 uV 12:24:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.487 uVs 12:24:46 Integrated Voltage Measurement... 12:24:55 Voltage Offset Correction: v_off_ini = 996.109 uV, v_off_fin = 991.674 uV 12:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.165 uVs 12:24:55 Integrated Voltage Measurement... 12:25:04 Voltage Offset Correction: v_off_ini = 983.081 uV, v_off_fin = 989.280 uV 12:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.458 uVs 12:25:08 I1X Average and RMS of Measurements VT = -76.489 +- 2.880 uVs I1X = 15.299 +- 0.577 uTm 12:25:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:25:15 Integrated Voltage Measurement... 12:25:24 Voltage Offset Correction: v_off_ini = 997.051 uV, v_off_fin = 980.088 uV 12:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.933 uVs 12:25:24 Integrated Voltage Measurement... 12:25:33 Voltage Offset Correction: v_off_ini = 992.216 uV, v_off_fin = 1001.084 uV 12:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.895 uVs 12:25:33 Integrated Voltage Measurement... 12:25:42 Voltage Offset Correction: v_off_ini = 993.451 uV, v_off_fin = 988.166 uV 12:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.752 uVs 12:25:42 Integrated Voltage Measurement... 12:25:51 Voltage Offset Correction: v_off_ini = 991.402 uV, v_off_fin = 999.397 uV 12:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.418 uVs 12:25:51 Integrated Voltage Measurement... 12:26:00 Voltage Offset Correction: v_off_ini = 1003.576 uV, v_off_fin = 980.295 uV 12:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.660 uVs 12:26:00 Integrated Voltage Measurement... 12:26:09 Voltage Offset Correction: v_off_ini = 991.635 uV, v_off_fin = 1002.078 uV 12:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.758 uVs 12:26:13 I1Y Average and RMS of Measurements VT = -215.403 +- 7.151 uVs I1Y = -43.080 +- 1.430 uTm 12:26:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:26:19 Integrated Voltage Measurement... 12:26:28 Voltage Offset Correction: v_off_ini = 990.200 uV, v_off_fin = 990.257 uV 12:26:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.738 uVs 12:26:28 Integrated Voltage Measurement... 12:26:37 Voltage Offset Correction: v_off_ini = 995.020 uV, v_off_fin = 1014.135 uV 12:26:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.454 uVs 12:26:37 Integrated Voltage Measurement... 12:26:46 Voltage Offset Correction: v_off_ini = 1001.352 uV, v_off_fin = 1000.455 uV 12:26:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.074 uVs 12:26:46 Integrated Voltage Measurement... 12:26:55 Voltage Offset Correction: v_off_ini = 1014.597 uV, v_off_fin = 1020.781 uV 12:26:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.024 uVs 12:26:55 Integrated Voltage Measurement... 12:27:04 Voltage Offset Correction: v_off_ini = 1014.785 uV, v_off_fin = 1001.951 uV 12:27:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.651 uVs 12:27:04 Integrated Voltage Measurement... 12:27:13 Voltage Offset Correction: v_off_ini = 1020.863 uV, v_off_fin = 1024.102 uV 12:27:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.153 uVs 12:27:15 I2X Average and RMS of Measurements VT = -119.182 +- 5.101 uVs I2X = 10.965 +- 0.469 uTm^2 12:27:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:27:20 Integrated Voltage Measurement... 12:27:29 Voltage Offset Correction: v_off_ini = 1013.690 uV, v_off_fin = 1014.007 uV 12:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.071 uVs 12:27:29 Integrated Voltage Measurement... 12:27:38 Voltage Offset Correction: v_off_ini = 1012.134 uV, v_off_fin = 1034.690 uV 12:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.024 uVs 12:27:38 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = 1021.102 uV, v_off_fin = 1015.620 uV 12:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.133 uVs 12:27:47 Integrated Voltage Measurement... 12:27:56 Voltage Offset Correction: v_off_ini = 1004.617 uV, v_off_fin = 1016.792 uV 12:27:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.027 uVs 12:27:57 Integrated Voltage Measurement... 12:28:06 Voltage Offset Correction: v_off_ini = 1019.945 uV, v_off_fin = 1013.622 uV 12:28:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -372.780 uVs 12:28:06 Integrated Voltage Measurement... 12:28:15 Voltage Offset Correction: v_off_ini = 1019.897 uV, v_off_fin = 1012.895 uV 12:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.453 uVs 12:28:17 I2Y Average and RMS of Measurements VT = -372.748 +- 2.271 uVs I2Y = -34.293 +- 0.209 uTm^2 12:28:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:28:25 Integrated Voltage Measurement... 12:28:34 Voltage Offset Correction: v_off_ini = 1020.747 uV, v_off_fin = 1015.400 uV 12:28:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.968 uVs 12:28:34 Integrated Voltage Measurement... 12:28:43 Voltage Offset Correction: v_off_ini = 1010.107 uV, v_off_fin = 1012.568 uV 12:28:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.459 uVs 12:28:43 Integrated Voltage Measurement... 12:28:52 Voltage Offset Correction: v_off_ini = 1002.930 uV, v_off_fin = 1001.401 uV 12:28:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.173 uVs 12:28:52 Integrated Voltage Measurement... 12:29:01 Voltage Offset Correction: v_off_ini = 1016.390 uV, v_off_fin = 1011.572 uV 12:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.696 uVs 12:29:01 Integrated Voltage Measurement... 12:29:10 Voltage Offset Correction: v_off_ini = 1017.694 uV, v_off_fin = 1010.853 uV 12:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.752 uVs 12:29:11 Integrated Voltage Measurement... 12:29:19 Voltage Offset Correction: v_off_ini = 1000.885 uV, v_off_fin = 996.871 uV 12:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.842 uVs 12:29:24 I1X Average and RMS of Measurements VT = -81.315 +- 6.280 uVs I1X = 16.264 +- 1.256 uTm 12:29:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:29:30 Integrated Voltage Measurement... 12:29:39 Voltage Offset Correction: v_off_ini = 1013.888 uV, v_off_fin = 993.414 uV 12:29:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.176 uVs 12:29:40 Integrated Voltage Measurement... 12:29:48 Voltage Offset Correction: v_off_ini = 997.961 uV, v_off_fin = 1019.082 uV 12:29:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.182 uVs 12:29:49 Integrated Voltage Measurement... 12:29:57 Voltage Offset Correction: v_off_ini = 996.218 uV, v_off_fin = 994.549 uV 12:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.069 uVs 12:29:58 Integrated Voltage Measurement... 12:30:06 Voltage Offset Correction: v_off_ini = 1006.243 uV, v_off_fin = 1027.563 uV 12:30:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.471 uVs 12:30:07 Integrated Voltage Measurement... 12:30:15 Voltage Offset Correction: v_off_ini = 1016.694 uV, v_off_fin = 1006.363 uV 12:30:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.634 uVs 12:30:16 Integrated Voltage Measurement... 12:30:24 Voltage Offset Correction: v_off_ini = 1008.865 uV, v_off_fin = 1029.341 uV 12:30:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.185 uVs 12:30:29 I1Y Average and RMS of Measurements VT = -216.119 +- 5.025 uVs I1Y = -43.220 +- 1.005 uTm 12:30:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:30:34 Integrated Voltage Measurement... 12:30:43 Voltage Offset Correction: v_off_ini = 998.377 uV, v_off_fin = 1008.121 uV 12:30:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.573 uVs 12:30:43 Integrated Voltage Measurement... 12:30:52 Voltage Offset Correction: v_off_ini = 1002.639 uV, v_off_fin = 1024.869 uV 12:30:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 123.976 uVs 12:30:52 Integrated Voltage Measurement... 12:31:01 Voltage Offset Correction: v_off_ini = 1016.479 uV, v_off_fin = 1015.143 uV 12:31:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.741 uVs 12:31:01 Integrated Voltage Measurement... 12:31:10 Voltage Offset Correction: v_off_ini = 1013.529 uV, v_off_fin = 1017.331 uV 12:31:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.610 uVs 12:31:10 Integrated Voltage Measurement... 12:31:19 Voltage Offset Correction: v_off_ini = 1010.044 uV, v_off_fin = 999.138 uV 12:31:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.912 uVs 12:31:19 Integrated Voltage Measurement... 12:31:28 Voltage Offset Correction: v_off_ini = 1010.639 uV, v_off_fin = 1019.132 uV 12:31:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.260 uVs 12:31:31 I2X Average and RMS of Measurements VT = -109.512 +- 7.658 uVs I2X = 10.076 +- 0.704 uTm^2 12:31:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:31:36 Integrated Voltage Measurement... 12:31:45 Voltage Offset Correction: v_off_ini = 1014.557 uV, v_off_fin = 1008.868 uV 12:31:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.712 uVs 12:31:45 Integrated Voltage Measurement... 12:31:54 Voltage Offset Correction: v_off_ini = 1014.560 uV, v_off_fin = 1014.857 uV 12:31:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.430 uVs 12:31:54 Integrated Voltage Measurement... 12:32:03 Voltage Offset Correction: v_off_ini = 1010.424 uV, v_off_fin = 1001.511 uV 12:32:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.012 uVs 12:32:03 Integrated Voltage Measurement... 12:32:12 Voltage Offset Correction: v_off_ini = 1009.699 uV, v_off_fin = 1005.202 uV 12:32:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.464 uVs 12:32:12 Integrated Voltage Measurement... 12:32:21 Voltage Offset Correction: v_off_ini = 1000.045 uV, v_off_fin = 1011.873 uV 12:32:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.976 uVs 12:32:21 Integrated Voltage Measurement... 12:32:30 Voltage Offset Correction: v_off_ini = 1003.210 uV, v_off_fin = 1004.889 uV 12:32:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.927 uVs 12:32:32 I2Y Average and RMS of Measurements VT = -370.753 +- 5.667 uVs I2Y = -34.109 +- 0.521 uTm^2 12:32:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:32:54 Integrated Voltage Measurement... 12:33:03 Voltage Offset Correction: v_off_ini = 1008.557 uV, v_off_fin = 999.973 uV 12:33:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.361 uVs 12:33:03 Integrated Voltage Measurement... 12:33:12 Voltage Offset Correction: v_off_ini = 983.010 uV, v_off_fin = 991.024 uV 12:33:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.172 uVs 12:33:12 Integrated Voltage Measurement... 12:33:21 Voltage Offset Correction: v_off_ini = 986.015 uV, v_off_fin = 979.863 uV 12:33:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.037 uVs 12:33:21 Integrated Voltage Measurement... 12:33:30 Voltage Offset Correction: v_off_ini = 985.022 uV, v_off_fin = 1002.825 uV 12:33:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.917 uVs 12:33:30 Integrated Voltage Measurement... 12:33:39 Voltage Offset Correction: v_off_ini = 996.947 uV, v_off_fin = 991.159 uV 12:33:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.317 uVs 12:33:39 Integrated Voltage Measurement... 12:33:48 Voltage Offset Correction: v_off_ini = 1002.540 uV, v_off_fin = 1001.169 uV 12:33:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.401 uVs 12:33:52 I1X Average and RMS of Measurements VT = -87.201 +- 9.119 uVs I1X = 17.440 +- 1.824 uTm 12:33:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:33:59 Integrated Voltage Measurement... 12:34:08 Voltage Offset Correction: v_off_ini = 1000.329 uV, v_off_fin = 996.881 uV 12:34:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.559 uVs 12:34:08 Integrated Voltage Measurement... 12:34:17 Voltage Offset Correction: v_off_ini = 1014.867 uV, v_off_fin = 1023.048 uV 12:34:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.387 uVs 12:34:17 Integrated Voltage Measurement... 12:34:26 Voltage Offset Correction: v_off_ini = 1006.244 uV, v_off_fin = 997.766 uV 12:34:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.050 uVs 12:34:26 Integrated Voltage Measurement... 12:34:35 Voltage Offset Correction: v_off_ini = 1000.745 uV, v_off_fin = 1020.616 uV 12:34:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.981 uVs 12:34:35 Integrated Voltage Measurement... 12:34:44 Voltage Offset Correction: v_off_ini = 1012.177 uV, v_off_fin = 997.265 uV 12:34:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.517 uVs 12:34:44 Integrated Voltage Measurement... 12:34:53 Voltage Offset Correction: v_off_ini = 1010.556 uV, v_off_fin = 1031.312 uV 12:34:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.563 uVs 12:34:57 I1Y Average and RMS of Measurements VT = -232.509 +- 3.993 uVs I1Y = -46.502 +- 0.799 uTm 12:35:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:35:05 Integrated Voltage Measurement... 12:35:14 Voltage Offset Correction: v_off_ini = 992.795 uV, v_off_fin = 983.236 uV 12:35:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.084 uVs 12:35:14 Integrated Voltage Measurement... 12:35:23 Voltage Offset Correction: v_off_ini = 999.561 uV, v_off_fin = 1005.993 uV 12:35:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.909 uVs 12:35:23 Integrated Voltage Measurement... 12:35:32 Voltage Offset Correction: v_off_ini = 993.335 uV, v_off_fin = 992.876 uV 12:35:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.607 uVs 12:35:32 Integrated Voltage Measurement... 12:35:41 Voltage Offset Correction: v_off_ini = 1002.599 uV, v_off_fin = 1013.810 uV 12:35:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.243 uVs 12:35:41 Integrated Voltage Measurement... 12:35:50 Voltage Offset Correction: v_off_ini = 987.974 uV, v_off_fin = 984.518 uV 12:35:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.518 uVs 12:35:50 Integrated Voltage Measurement... 12:35:59 Voltage Offset Correction: v_off_ini = 990.500 uV, v_off_fin = 1010.507 uV 12:35:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.975 uVs 12:36:01 I2X Average and RMS of Measurements VT = -111.056 +- 6.410 uVs I2X = 10.217 +- 0.590 uTm^2 12:36:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:36:09 Integrated Voltage Measurement... 12:36:18 Voltage Offset Correction: v_off_ini = 990.922 uV, v_off_fin = 986.279 uV 12:36:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.317 uVs 12:36:18 Integrated Voltage Measurement... 12:36:27 Voltage Offset Correction: v_off_ini = 990.633 uV, v_off_fin = 991.175 uV 12:36:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 387.163 uVs 12:36:27 Integrated Voltage Measurement... 12:36:36 Voltage Offset Correction: v_off_ini = 987.693 uV, v_off_fin = 962.302 uV 12:36:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.360 uVs 12:36:36 Integrated Voltage Measurement... 12:36:45 Voltage Offset Correction: v_off_ini = 983.955 uV, v_off_fin = 992.767 uV 12:36:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.431 uVs 12:36:45 Integrated Voltage Measurement... 12:36:54 Voltage Offset Correction: v_off_ini = 978.068 uV, v_off_fin = 975.650 uV 12:36:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.737 uVs 12:36:54 Integrated Voltage Measurement... 12:37:03 Voltage Offset Correction: v_off_ini = 967.405 uV, v_off_fin = 948.581 uV 12:37:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.502 uVs 12:37:06 I2Y Average and RMS of Measurements VT = -375.918 +- 3.742 uVs I2Y = -34.584 +- 0.344 uTm^2 12:37:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:37:15 Integrated Voltage Measurement... 12:37:24 Voltage Offset Correction: v_off_ini = 982.948 uV, v_off_fin = 975.126 uV 12:37:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -91.646 uVs 12:37:24 Integrated Voltage Measurement... 12:37:33 Voltage Offset Correction: v_off_ini = 994.247 uV, v_off_fin = 1002.845 uV 12:37:33 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 63.273 uVs 12:37:33 Integrated Voltage Measurement... 12:37:42 Voltage Offset Correction: v_off_ini = 1001.457 uV, v_off_fin = 992.906 uV 12:37:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.839 uVs 12:37:42 Integrated Voltage Measurement... 12:37:51 Voltage Offset Correction: v_off_ini = 994.404 uV, v_off_fin = 992.336 uV 12:37:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.429 uVs 12:37:51 Integrated Voltage Measurement... 12:38:00 Voltage Offset Correction: v_off_ini = 971.220 uV, v_off_fin = 974.866 uV 12:38:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.657 uVs 12:38:00 Integrated Voltage Measurement... 12:38:09 Voltage Offset Correction: v_off_ini = 994.756 uV, v_off_fin = 992.178 uV 12:38:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.474 uVs 12:38:13 I1X Average and RMS of Measurements VT = -85.553 +- 10.285 uVs I1X = 17.112 +- 2.056 uTm 12:38:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:38:20 Integrated Voltage Measurement... 12:38:29 Voltage Offset Correction: v_off_ini = 994.399 uV, v_off_fin = 1001.205 uV 12:38:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.508 uVs 12:38:29 Integrated Voltage Measurement... 12:38:38 Voltage Offset Correction: v_off_ini = 1014.560 uV, v_off_fin = 1005.833 uV 12:38:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 224.061 uVs 12:38:38 Integrated Voltage Measurement... 12:38:47 Voltage Offset Correction: v_off_ini = 991.258 uV, v_off_fin = 985.748 uV 12:38:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.097 uVs 12:38:47 Integrated Voltage Measurement... 12:38:56 Voltage Offset Correction: v_off_ini = 996.335 uV, v_off_fin = 1006.959 uV 12:38:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.858 uVs 12:38:56 Integrated Voltage Measurement... 12:39:05 Voltage Offset Correction: v_off_ini = 990.381 uV, v_off_fin = 979.795 uV 12:39:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.714 uVs 12:39:05 Integrated Voltage Measurement... 12:39:14 Voltage Offset Correction: v_off_ini = 980.327 uV, v_off_fin = 998.745 uV 12:39:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.216 uVs 12:39:18 I1Y Average and RMS of Measurements VT = -219.909 +- 3.670 uVs I1Y = -43.983 +- 0.734 uTm 12:39:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:39:26 Integrated Voltage Measurement... 12:39:35 Voltage Offset Correction: v_off_ini = 977.983 uV, v_off_fin = 970.585 uV 12:39:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.977 uVs 12:39:35 Integrated Voltage Measurement... 12:39:44 Voltage Offset Correction: v_off_ini = 991.053 uV, v_off_fin = 1003.541 uV 12:39:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.137 uVs 12:39:44 Integrated Voltage Measurement... 12:39:53 Voltage Offset Correction: v_off_ini = 979.655 uV, v_off_fin = 985.603 uV 12:39:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.541 uVs 12:39:53 Integrated Voltage Measurement... 12:40:02 Voltage Offset Correction: v_off_ini = 983.345 uV, v_off_fin = 994.399 uV 12:40:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.832 uVs 12:40:02 Integrated Voltage Measurement... 12:40:11 Voltage Offset Correction: v_off_ini = 987.445 uV, v_off_fin = 986.029 uV 12:40:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.884 uVs 12:40:11 Integrated Voltage Measurement... 12:40:20 Voltage Offset Correction: v_off_ini = 995.853 uV, v_off_fin = 997.766 uV 12:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.606 uVs 12:40:23 I2X Average and RMS of Measurements VT = -110.496 +- 1.454 uVs I2X = 10.166 +- 0.133 uTm^2 12:40:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:40:30 Integrated Voltage Measurement... 12:40:39 Voltage Offset Correction: v_off_ini = 965.834 uV, v_off_fin = 977.324 uV 12:40:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.513 uVs 12:40:39 Integrated Voltage Measurement... 12:40:48 Voltage Offset Correction: v_off_ini = 980.585 uV, v_off_fin = 969.503 uV 12:40:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.594 uVs 12:40:48 Integrated Voltage Measurement... 12:40:57 Voltage Offset Correction: v_off_ini = 975.430 uV, v_off_fin = 974.739 uV 12:40:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -380.280 uVs 12:40:57 Integrated Voltage Measurement... 12:41:06 Voltage Offset Correction: v_off_ini = 968.309 uV, v_off_fin = 983.654 uV 12:41:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.474 uVs 12:41:06 Integrated Voltage Measurement... 12:41:15 Voltage Offset Correction: v_off_ini = 979.799 uV, v_off_fin = 977.015 uV 12:41:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.664 uVs 12:41:16 Integrated Voltage Measurement... 12:41:25 Voltage Offset Correction: v_off_ini = 975.895 uV, v_off_fin = 968.814 uV 12:41:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.395 uVs 12:41:27 I2Y Average and RMS of Measurements VT = -365.653 +- 5.250 uVs I2Y = -33.641 +- 0.484 uTm^2 12:41:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:36 Integrated Voltage Measurement... 12:41:45 Voltage Offset Correction: v_off_ini = 964.974 uV, v_off_fin = 963.704 uV 12:41:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.244 uVs 12:41:45 Integrated Voltage Measurement... 12:41:54 Voltage Offset Correction: v_off_ini = 990.507 uV, v_off_fin = 987.677 uV 12:41:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.845 uVs 12:41:54 Integrated Voltage Measurement... 12:42:03 Voltage Offset Correction: v_off_ini = 998.510 uV, v_off_fin = 970.641 uV 12:42:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.164 uVs 12:42:03 Integrated Voltage Measurement... 12:42:12 Voltage Offset Correction: v_off_ini = 977.339 uV, v_off_fin = 979.147 uV 12:42:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.739 uVs 12:42:12 Integrated Voltage Measurement... 12:42:21 Voltage Offset Correction: v_off_ini = 978.567 uV, v_off_fin = 980.503 uV 12:42:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.018 uVs 12:42:21 Integrated Voltage Measurement... 12:42:30 Voltage Offset Correction: v_off_ini = 970.899 uV, v_off_fin = 984.533 uV 12:42:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.675 uVs 12:42:34 I1X Average and RMS of Measurements VT = -80.614 +- 15.334 uVs I1X = 16.123 +- 3.067 uTm 12:42:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:41 Integrated Voltage Measurement... 12:42:50 Voltage Offset Correction: v_off_ini = 953.501 uV, v_off_fin = 954.126 uV 12:42:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.883 uVs 12:42:50 Integrated Voltage Measurement... 12:42:59 Voltage Offset Correction: v_off_ini = 958.389 uV, v_off_fin = 971.594 uV 12:42:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.062 uVs 12:42:59 Integrated Voltage Measurement... 12:43:08 Voltage Offset Correction: v_off_ini = 963.301 uV, v_off_fin = 948.914 uV 12:43:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.365 uVs 12:43:08 Integrated Voltage Measurement... 12:43:17 Voltage Offset Correction: v_off_ini = 947.418 uV, v_off_fin = 976.342 uV 12:43:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.151 uVs 12:43:17 Integrated Voltage Measurement... 12:43:26 Voltage Offset Correction: v_off_ini = 961.255 uV, v_off_fin = 950.774 uV 12:43:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.811 uVs 12:43:26 Integrated Voltage Measurement... 12:43:35 Voltage Offset Correction: v_off_ini = 959.151 uV, v_off_fin = 967.616 uV 12:43:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.149 uVs 12:43:39 I1Y Average and RMS of Measurements VT = -219.570 +- 3.480 uVs I1Y = -43.914 +- 0.696 uTm 12:43:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:47 Integrated Voltage Measurement... 12:43:56 Voltage Offset Correction: v_off_ini = 956.306 uV, v_off_fin = 950.349 uV 12:43:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.880 uVs 12:43:56 Integrated Voltage Measurement... 12:44:05 Voltage Offset Correction: v_off_ini = 943.091 uV, v_off_fin = 957.879 uV 12:44:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.943 uVs 12:44:05 Integrated Voltage Measurement... 12:44:14 Voltage Offset Correction: v_off_ini = 955.879 uV, v_off_fin = 954.882 uV 12:44:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.055 uVs 12:44:14 Integrated Voltage Measurement... 12:44:23 Voltage Offset Correction: v_off_ini = 963.459 uV, v_off_fin = 957.586 uV 12:44:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.043 uVs 12:44:23 Integrated Voltage Measurement... 12:44:32 Voltage Offset Correction: v_off_ini = 950.407 uV, v_off_fin = 946.850 uV 12:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.752 uVs 12:44:32 Integrated Voltage Measurement... 12:44:41 Voltage Offset Correction: v_off_ini = 947.952 uV, v_off_fin = 956.821 uV 12:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.745 uVs 12:44:44 I2X Average and RMS of Measurements VT = -114.069 +- 3.559 uVs I2X = 10.494 +- 0.327 uTm^2 12:44:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:51 Integrated Voltage Measurement... 12:45:00 Voltage Offset Correction: v_off_ini = 948.246 uV, v_off_fin = 949.569 uV 12:45:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.943 uVs 12:45:01 Integrated Voltage Measurement... 12:45:09 Voltage Offset Correction: v_off_ini = 955.180 uV, v_off_fin = 944.189 uV 12:45:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.043 uVs 12:45:10 Integrated Voltage Measurement... 12:45:19 Voltage Offset Correction: v_off_ini = 950.333 uV, v_off_fin = 954.110 uV 12:45:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.490 uVs 12:45:19 Integrated Voltage Measurement... 12:45:28 Voltage Offset Correction: v_off_ini = 947.193 uV, v_off_fin = 950.411 uV 12:45:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.077 uVs 12:45:28 Integrated Voltage Measurement... 12:45:37 Voltage Offset Correction: v_off_ini = 957.167 uV, v_off_fin = 954.208 uV 12:45:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.514 uVs 12:45:37 Integrated Voltage Measurement... 12:45:46 Voltage Offset Correction: v_off_ini = 946.264 uV, v_off_fin = 954.574 uV 12:45:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.701 uVs 12:45:48 I2Y Average and RMS of Measurements VT = -360.961 +- 4.170 uVs I2Y = -33.208 +- 0.384 uTm^2 12:45:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:45:57 Integrated Voltage Measurement... 12:46:06 Voltage Offset Correction: v_off_ini = 949.577 uV, v_off_fin = 944.470 uV 12:46:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.097 uVs 12:46:06 Integrated Voltage Measurement... 12:46:15 Voltage Offset Correction: v_off_ini = 951.550 uV, v_off_fin = 941.995 uV 12:46:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.183 uVs 12:46:15 Integrated Voltage Measurement... 12:46:24 Voltage Offset Correction: v_off_ini = 957.126 uV, v_off_fin = 945.272 uV 12:46:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.572 uVs 12:46:24 Integrated Voltage Measurement... 12:46:33 Voltage Offset Correction: v_off_ini = 944.561 uV, v_off_fin = 954.655 uV 12:46:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 79.796 uVs 12:46:33 Integrated Voltage Measurement... 12:46:42 Voltage Offset Correction: v_off_ini = 942.236 uV, v_off_fin = 934.947 uV 12:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.297 uVs 12:46:42 Integrated Voltage Measurement... 12:46:51 Voltage Offset Correction: v_off_ini = 946.931 uV, v_off_fin = 937.862 uV 12:46:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.598 uVs 12:46:55 I1X Average and RMS of Measurements VT = -73.091 +- 2.381 uVs I1X = 14.620 +- 0.476 uTm 12:46:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:47:02 Integrated Voltage Measurement... 12:47:11 Voltage Offset Correction: v_off_ini = 942.927 uV, v_off_fin = 926.594 uV 12:47:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -206.721 uVs 12:47:11 Integrated Voltage Measurement... 12:47:20 Voltage Offset Correction: v_off_ini = 938.316 uV, v_off_fin = 950.484 uV 12:47:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.998 uVs 12:47:20 Integrated Voltage Measurement... 12:47:29 Voltage Offset Correction: v_off_ini = 939.144 uV, v_off_fin = 932.564 uV 12:47:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.842 uVs 12:47:29 Integrated Voltage Measurement... 12:47:38 Voltage Offset Correction: v_off_ini = 942.082 uV, v_off_fin = 956.440 uV 12:47:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.109 uVs 12:47:38 Integrated Voltage Measurement... 12:47:47 Voltage Offset Correction: v_off_ini = 960.850 uV, v_off_fin = 957.752 uV 12:47:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.577 uVs 12:47:47 Integrated Voltage Measurement... 12:47:56 Voltage Offset Correction: v_off_ini = 964.276 uV, v_off_fin = 971.621 uV 12:47:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.534 uVs 12:48:00 I1Y Average and RMS of Measurements VT = -207.630 +- 3.327 uVs I1Y = -41.529 +- 0.664 uTm 12:48:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:48:08 Integrated Voltage Measurement... 12:48:17 Voltage Offset Correction: v_off_ini = 953.091 uV, v_off_fin = 947.187 uV 12:48:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.378 uVs 12:48:17 Integrated Voltage Measurement... 12:48:26 Voltage Offset Correction: v_off_ini = 961.348 uV, v_off_fin = 975.081 uV 12:48:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.808 uVs 12:48:26 Integrated Voltage Measurement... 12:48:35 Voltage Offset Correction: v_off_ini = 959.384 uV, v_off_fin = 958.558 uV 12:48:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.681 uVs 12:48:35 Integrated Voltage Measurement... 12:48:44 Voltage Offset Correction: v_off_ini = 970.237 uV, v_off_fin = 975.230 uV 12:48:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.340 uVs 12:48:44 Integrated Voltage Measurement... 12:48:53 Voltage Offset Correction: v_off_ini = 965.004 uV, v_off_fin = 945.009 uV 12:48:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.297 uVs 12:48:53 Integrated Voltage Measurement... 12:49:02 Voltage Offset Correction: v_off_ini = 961.776 uV, v_off_fin = 973.407 uV 12:49:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.098 uVs 12:49:05 I2X Average and RMS of Measurements VT = -106.101 +- 2.326 uVs I2X = 9.762 +- 0.214 uTm^2 12:49:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:49:13 Integrated Voltage Measurement... 12:49:22 Voltage Offset Correction: v_off_ini = 965.365 uV, v_off_fin = 958.417 uV 12:49:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.197 uVs 12:49:22 Integrated Voltage Measurement... 12:49:31 Voltage Offset Correction: v_off_ini = 965.767 uV, v_off_fin = 960.539 uV 12:49:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 361.557 uVs 12:49:31 Integrated Voltage Measurement... 12:49:40 Voltage Offset Correction: v_off_ini = 957.056 uV, v_off_fin = 959.412 uV 12:49:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.915 uVs 12:49:40 Integrated Voltage Measurement... 12:49:49 Voltage Offset Correction: v_off_ini = 968.449 uV, v_off_fin = 974.472 uV 12:49:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.139 uVs 12:49:49 Integrated Voltage Measurement... 12:49:58 Voltage Offset Correction: v_off_ini = 962.496 uV, v_off_fin = 968.068 uV 12:49:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.432 uVs 12:49:58 Integrated Voltage Measurement... 12:50:07 Voltage Offset Correction: v_off_ini = 973.416 uV, v_off_fin = 961.838 uV 12:50:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.939 uVs 12:50:09 I2Y Average and RMS of Measurements VT = -347.030 +- 6.632 uVs I2Y = -31.927 +- 0.611 uTm^2 12:50:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:50:18 Integrated Voltage Measurement... 12:50:27 Voltage Offset Correction: v_off_ini = 973.670 uV, v_off_fin = 961.201 uV 12:50:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -65.122 uVs 12:50:27 Integrated Voltage Measurement... 12:50:36 Voltage Offset Correction: v_off_ini = 964.317 uV, v_off_fin = 973.849 uV 12:50:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.297 uVs 12:50:36 Integrated Voltage Measurement... 12:50:45 Voltage Offset Correction: v_off_ini = 951.607 uV, v_off_fin = 962.495 uV 12:50:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.563 uVs 12:50:45 Integrated Voltage Measurement... 12:50:54 Voltage Offset Correction: v_off_ini = 957.762 uV, v_off_fin = 956.541 uV 12:50:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.121 uVs 12:50:54 Integrated Voltage Measurement... 12:51:03 Voltage Offset Correction: v_off_ini = 955.931 uV, v_off_fin = 956.462 uV 12:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.159 uVs 12:51:03 Integrated Voltage Measurement... 12:51:12 Voltage Offset Correction: v_off_ini = 950.047 uV, v_off_fin = 973.809 uV 12:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.760 uVs 12:51:17 I1X Average and RMS of Measurements VT = -72.670 +- 2.373 uVs I1X = 14.535 +- 0.474 uTm 12:51:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:51:23 Integrated Voltage Measurement... 12:51:32 Voltage Offset Correction: v_off_ini = 978.067 uV, v_off_fin = 977.697 uV 12:51:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.719 uVs 12:51:32 Integrated Voltage Measurement... 12:51:41 Voltage Offset Correction: v_off_ini = 971.578 uV, v_off_fin = 988.196 uV 12:51:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.975 uVs 12:51:41 Integrated Voltage Measurement... 12:51:50 Voltage Offset Correction: v_off_ini = 962.146 uV, v_off_fin = 958.944 uV 12:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.232 uVs 12:51:50 Integrated Voltage Measurement... 12:51:59 Voltage Offset Correction: v_off_ini = 969.014 uV, v_off_fin = 996.316 uV 12:51:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.686 uVs 12:51:59 Integrated Voltage Measurement... 12:52:08 Voltage Offset Correction: v_off_ini = 976.786 uV, v_off_fin = 975.467 uV 12:52:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.254 uVs 12:52:08 Integrated Voltage Measurement... 12:52:17 Voltage Offset Correction: v_off_ini = 987.168 uV, v_off_fin = 1005.084 uV 12:52:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.449 uVs 12:52:22 I1Y Average and RMS of Measurements VT = -211.219 +- 3.880 uVs I1Y = -42.244 +- 0.776 uTm 12:52:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:52:29 Integrated Voltage Measurement... 12:52:38 Voltage Offset Correction: v_off_ini = 977.957 uV, v_off_fin = 964.553 uV 12:52:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.378 uVs 12:52:38 Integrated Voltage Measurement... 12:52:47 Voltage Offset Correction: v_off_ini = 969.693 uV, v_off_fin = 974.759 uV 12:52:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.250 uVs 12:52:47 Integrated Voltage Measurement... 12:52:56 Voltage Offset Correction: v_off_ini = 974.275 uV, v_off_fin = 960.177 uV 12:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.092 uVs 12:52:57 Integrated Voltage Measurement... 12:53:06 Voltage Offset Correction: v_off_ini = 965.670 uV, v_off_fin = 968.145 uV 12:53:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.856 uVs 12:53:06 Integrated Voltage Measurement... 12:53:15 Voltage Offset Correction: v_off_ini = 961.364 uV, v_off_fin = 962.591 uV 12:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.014 uVs 12:53:15 Integrated Voltage Measurement... 12:53:24 Voltage Offset Correction: v_off_ini = 965.250 uV, v_off_fin = 973.873 uV 12:53:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.444 uVs 12:53:26 I2X Average and RMS of Measurements VT = -100.839 +- 4.903 uVs I2X = 9.277 +- 0.451 uTm^2 12:53:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:53:34 Integrated Voltage Measurement... 12:53:43 Voltage Offset Correction: v_off_ini = 960.748 uV, v_off_fin = 959.521 uV 12:53:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.724 uVs 12:53:43 Integrated Voltage Measurement... 12:53:52 Voltage Offset Correction: v_off_ini = 961.906 uV, v_off_fin = 957.593 uV 12:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.888 uVs 12:53:52 Integrated Voltage Measurement... 12:54:01 Voltage Offset Correction: v_off_ini = 957.952 uV, v_off_fin = 963.099 uV 12:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.137 uVs 12:54:01 Integrated Voltage Measurement... 12:54:10 Voltage Offset Correction: v_off_ini = 959.462 uV, v_off_fin = 965.252 uV 12:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.583 uVs 12:54:10 Integrated Voltage Measurement... 12:54:19 Voltage Offset Correction: v_off_ini = 958.767 uV, v_off_fin = 959.529 uV 12:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.264 uVs 12:54:19 Integrated Voltage Measurement... 12:54:28 Voltage Offset Correction: v_off_ini = 953.957 uV, v_off_fin = 955.487 uV 12:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.917 uVs 12:54:30 I2Y Average and RMS of Measurements VT = -348.419 +- 2.235 uVs I2Y = -32.055 +- 0.206 uTm^2 12:54:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:54:42 Integrated Voltage Measurement... 12:54:51 Voltage Offset Correction: v_off_ini = 964.193 uV, v_off_fin = 959.117 uV 12:54:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.534 uVs 12:54:52 Integrated Voltage Measurement... 12:55:00 Voltage Offset Correction: v_off_ini = 952.035 uV, v_off_fin = 948.170 uV 12:55:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.711 uVs 12:55:01 Integrated Voltage Measurement... 12:55:10 Voltage Offset Correction: v_off_ini = 943.694 uV, v_off_fin = 949.989 uV 12:55:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.355 uVs 12:55:10 Integrated Voltage Measurement... 12:55:19 Voltage Offset Correction: v_off_ini = 923.414 uV, v_off_fin = 913.052 uV 12:55:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.030 uVs 12:55:19 Integrated Voltage Measurement... 12:55:28 Voltage Offset Correction: v_off_ini = 930.914 uV, v_off_fin = 924.383 uV 12:55:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.985 uVs 12:55:28 Integrated Voltage Measurement... 12:55:37 Voltage Offset Correction: v_off_ini = 924.142 uV, v_off_fin = 927.597 uV 12:55:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.463 uVs 12:55:41 I1X Average and RMS of Measurements VT = -75.180 +- 3.517 uVs I1X = 15.036 +- 0.703 uTm 12:55:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:55:48 Integrated Voltage Measurement... 12:55:57 Voltage Offset Correction: v_off_ini = 925.471 uV, v_off_fin = 919.435 uV 12:55:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -205.907 uVs 12:55:57 Integrated Voltage Measurement... 12:56:06 Voltage Offset Correction: v_off_ini = 928.344 uV, v_off_fin = 933.431 uV 12:56:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.184 uVs 12:56:06 Integrated Voltage Measurement... 12:56:15 Voltage Offset Correction: v_off_ini = 927.257 uV, v_off_fin = 910.647 uV 12:56:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.421 uVs 12:56:15 Integrated Voltage Measurement... 12:56:24 Voltage Offset Correction: v_off_ini = 921.617 uV, v_off_fin = 916.076 uV 12:56:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.982 uVs 12:56:24 Integrated Voltage Measurement... 12:56:33 Voltage Offset Correction: v_off_ini = 924.949 uV, v_off_fin = 906.918 uV 12:56:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.810 uVs 12:56:33 Integrated Voltage Measurement... 12:56:42 Voltage Offset Correction: v_off_ini = 917.318 uV, v_off_fin = 928.243 uV 12:56:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.664 uVs 12:56:46 I1Y Average and RMS of Measurements VT = -222.661 +- 7.869 uVs I1Y = -44.533 +- 1.573 uTm 12:56:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:56:51 Integrated Voltage Measurement... 12:57:00 Voltage Offset Correction: v_off_ini = 907.588 uV, v_off_fin = 914.422 uV 12:57:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.393 uVs 12:57:00 Integrated Voltage Measurement... 12:57:09 Voltage Offset Correction: v_off_ini = 934.079 uV, v_off_fin = 942.972 uV 12:57:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.104 uVs 12:57:09 Integrated Voltage Measurement... 12:57:18 Voltage Offset Correction: v_off_ini = 931.066 uV, v_off_fin = 923.055 uV 12:57:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.924 uVs 12:57:18 Integrated Voltage Measurement... 12:57:27 Voltage Offset Correction: v_off_ini = 931.099 uV, v_off_fin = 934.996 uV 12:57:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.866 uVs 12:57:27 Integrated Voltage Measurement... 12:57:36 Voltage Offset Correction: v_off_ini = 930.136 uV, v_off_fin = 912.007 uV 12:57:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.073 uVs 12:57:36 Integrated Voltage Measurement... 12:57:45 Voltage Offset Correction: v_off_ini = 920.755 uV, v_off_fin = 936.556 uV 12:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.394 uVs 12:57:48 I2X Average and RMS of Measurements VT = -100.459 +- 3.687 uVs I2X = 9.242 +- 0.339 uTm^2 12:57:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:57:53 Integrated Voltage Measurement... 12:58:02 Voltage Offset Correction: v_off_ini = 919.207 uV, v_off_fin = 913.795 uV 12:58:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -360.853 uVs 12:58:02 Integrated Voltage Measurement... 12:58:11 Voltage Offset Correction: v_off_ini = 910.590 uV, v_off_fin = 905.172 uV 12:58:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.577 uVs 12:58:11 Integrated Voltage Measurement... 12:58:20 Voltage Offset Correction: v_off_ini = 903.671 uV, v_off_fin = 909.549 uV 12:58:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.125 uVs 12:58:20 Integrated Voltage Measurement... 12:58:29 Voltage Offset Correction: v_off_ini = 912.647 uV, v_off_fin = 912.298 uV 12:58:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.463 uVs 12:58:29 Integrated Voltage Measurement... 12:58:38 Voltage Offset Correction: v_off_ini = 962.176 uV, v_off_fin = 902.618 uV 12:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -396.064 uVs 12:58:38 Integrated Voltage Measurement... 12:58:47 Voltage Offset Correction: v_off_ini = 903.494 uV, v_off_fin = 894.153 uV 12:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.027 uVs 12:58:50 I2Y Average and RMS of Measurements VT = -360.185 +- 5.097 uVs I2Y = -33.138 +- 0.470 uTm^2 12:58:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:58:58 Integrated Voltage Measurement... 12:59:07 Voltage Offset Correction: v_off_ini = 914.054 uV, v_off_fin = 909.711 uV 12:59:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.695 uVs 12:59:07 Integrated Voltage Measurement... 12:59:16 Voltage Offset Correction: v_off_ini = 910.809 uV, v_off_fin = 912.955 uV 12:59:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 71.150 uVs 12:59:16 Integrated Voltage Measurement... 12:59:25 Voltage Offset Correction: v_off_ini = 912.200 uV, v_off_fin = 907.531 uV 12:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.501 uVs 12:59:25 Integrated Voltage Measurement... 12:59:34 Voltage Offset Correction: v_off_ini = 915.061 uV, v_off_fin = 922.195 uV 12:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.128 uVs 12:59:34 Integrated Voltage Measurement... 12:59:43 Voltage Offset Correction: v_off_ini = 921.682 uV, v_off_fin = 910.815 uV 12:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.329 uVs 12:59:43 Integrated Voltage Measurement... 12:59:52 Voltage Offset Correction: v_off_ini = 918.782 uV, v_off_fin = 935.049 uV 12:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.499 uVs 12:59:56 I1X Average and RMS of Measurements VT = -63.717 +- 6.283 uVs I1X = 12.744 +- 1.257 uTm 12:59:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:00:03 Integrated Voltage Measurement... 13:00:12 Voltage Offset Correction: v_off_ini = 931.518 uV, v_off_fin = 912.644 uV 13:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.916 uVs 13:00:12 Integrated Voltage Measurement... 13:00:21 Voltage Offset Correction: v_off_ini = 933.952 uV, v_off_fin = 947.532 uV 13:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.302 uVs 13:00:21 Integrated Voltage Measurement... 13:00:30 Voltage Offset Correction: v_off_ini = 943.027 uV, v_off_fin = 924.865 uV 13:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.898 uVs 13:00:30 Integrated Voltage Measurement... 13:00:39 Voltage Offset Correction: v_off_ini = 935.150 uV, v_off_fin = 951.433 uV 13:00:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.657 uVs 13:00:39 Integrated Voltage Measurement... 13:00:48 Voltage Offset Correction: v_off_ini = 940.928 uV, v_off_fin = 936.844 uV 13:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.981 uVs 13:00:48 Integrated Voltage Measurement... 13:00:57 Voltage Offset Correction: v_off_ini = 934.587 uV, v_off_fin = 949.244 uV 13:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.439 uVs 13:01:01 I1Y Average and RMS of Measurements VT = -226.699 +- 4.322 uVs I1Y = -45.340 +- 0.864 uTm 13:01:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:01:06 Integrated Voltage Measurement... 13:01:15 Voltage Offset Correction: v_off_ini = 932.695 uV, v_off_fin = 923.949 uV 13:01:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.762 uVs 13:01:15 Integrated Voltage Measurement... 13:01:24 Voltage Offset Correction: v_off_ini = 924.291 uV, v_off_fin = 938.195 uV 13:01:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.409 uVs 13:01:25 Integrated Voltage Measurement... 13:01:33 Voltage Offset Correction: v_off_ini = 938.102 uV, v_off_fin = 921.475 uV 13:01:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.061 uVs 13:01:34 Integrated Voltage Measurement... 13:01:43 Voltage Offset Correction: v_off_ini = 926.873 uV, v_off_fin = 928.456 uV 13:01:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.235 uVs 13:01:43 Integrated Voltage Measurement... 13:01:52 Voltage Offset Correction: v_off_ini = 922.399 uV, v_off_fin = 913.710 uV 13:01:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.381 uVs 13:01:52 Integrated Voltage Measurement... 13:02:01 Voltage Offset Correction: v_off_ini = 927.146 uV, v_off_fin = 942.379 uV 13:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.308 uVs 13:02:03 I2X Average and RMS of Measurements VT = -105.693 +- 3.997 uVs I2X = 9.724 +- 0.368 uTm^2 13:02:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:02:08 Integrated Voltage Measurement... 13:02:17 Voltage Offset Correction: v_off_ini = 930.726 uV, v_off_fin = 917.421 uV 13:02:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.263 uVs 13:02:17 Integrated Voltage Measurement... 13:02:26 Voltage Offset Correction: v_off_ini = 934.896 uV, v_off_fin = 917.821 uV 13:02:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.236 uVs 13:02:26 Integrated Voltage Measurement... 13:02:35 Voltage Offset Correction: v_off_ini = 923.463 uV, v_off_fin = 925.073 uV 13:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.758 uVs 13:02:35 Integrated Voltage Measurement... 13:02:44 Voltage Offset Correction: v_off_ini = 921.428 uV, v_off_fin = 929.732 uV 13:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.663 uVs 13:02:44 Integrated Voltage Measurement... 13:02:53 Voltage Offset Correction: v_off_ini = 929.322 uV, v_off_fin = 931.253 uV 13:02:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.955 uVs 13:02:53 Integrated Voltage Measurement... 13:03:02 Voltage Offset Correction: v_off_ini = 931.701 uV, v_off_fin = 921.618 uV 13:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.909 uVs 13:03:05 I2Y Average and RMS of Measurements VT = -357.964 +- 5.478 uVs I2Y = -32.933 +- 0.504 uTm^2 13:03:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:13 Integrated Voltage Measurement... 13:03:22 Voltage Offset Correction: v_off_ini = 930.030 uV, v_off_fin = 917.702 uV 13:03:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.702 uVs 13:03:22 Integrated Voltage Measurement... 13:03:31 Voltage Offset Correction: v_off_ini = 902.871 uV, v_off_fin = 915.839 uV 13:03:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.831 uVs 13:03:31 Integrated Voltage Measurement... 13:03:40 Voltage Offset Correction: v_off_ini = 912.762 uV, v_off_fin = 907.979 uV 13:03:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.290 uVs 13:03:40 Integrated Voltage Measurement... 13:03:49 Voltage Offset Correction: v_off_ini = 921.746 uV, v_off_fin = 915.517 uV 13:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.895 uVs 13:03:49 Integrated Voltage Measurement... 13:03:58 Voltage Offset Correction: v_off_ini = 902.593 uV, v_off_fin = 902.798 uV 13:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.570 uVs 13:03:58 Integrated Voltage Measurement... 13:04:07 Voltage Offset Correction: v_off_ini = 903.571 uV, v_off_fin = 894.523 uV 13:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.554 uVs 13:04:12 I1X Average and RMS of Measurements VT = -85.474 +- 5.569 uVs I1X = 17.095 +- 1.114 uTm 13:04:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:04:18 Integrated Voltage Measurement... 13:04:27 Voltage Offset Correction: v_off_ini = 914.574 uV, v_off_fin = 900.684 uV 13:04:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.810 uVs 13:04:27 Integrated Voltage Measurement... 13:04:36 Voltage Offset Correction: v_off_ini = 924.565 uV, v_off_fin = 935.315 uV 13:04:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.382 uVs 13:04:36 Integrated Voltage Measurement... 13:04:45 Voltage Offset Correction: v_off_ini = 922.481 uV, v_off_fin = 895.282 uV 13:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.004 uVs 13:04:45 Integrated Voltage Measurement... 13:04:54 Voltage Offset Correction: v_off_ini = 905.821 uV, v_off_fin = 914.343 uV 13:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.194 uVs 13:04:55 Integrated Voltage Measurement... 13:05:03 Voltage Offset Correction: v_off_ini = 904.948 uV, v_off_fin = 903.480 uV 13:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.617 uVs 13:05:04 Integrated Voltage Measurement... 13:05:12 Voltage Offset Correction: v_off_ini = 903.795 uV, v_off_fin = 910.281 uV 13:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.619 uVs 13:05:17 I1Y Average and RMS of Measurements VT = -223.438 +- 3.056 uVs I1Y = -44.688 +- 0.611 uTm 13:05:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:22 Integrated Voltage Measurement... 13:05:31 Voltage Offset Correction: v_off_ini = 896.781 uV, v_off_fin = 887.053 uV 13:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.539 uVs 13:05:31 Integrated Voltage Measurement... 13:05:40 Voltage Offset Correction: v_off_ini = 899.894 uV, v_off_fin = 918.379 uV 13:05:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.426 uVs 13:05:40 Integrated Voltage Measurement... 13:05:49 Voltage Offset Correction: v_off_ini = 909.516 uV, v_off_fin = 897.920 uV 13:05:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.499 uVs 13:05:49 Integrated Voltage Measurement... 13:05:58 Voltage Offset Correction: v_off_ini = 907.881 uV, v_off_fin = 911.640 uV 13:05:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.587 uVs 13:05:58 Integrated Voltage Measurement... 13:06:07 Voltage Offset Correction: v_off_ini = 909.453 uV, v_off_fin = 895.459 uV 13:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.983 uVs 13:06:07 Integrated Voltage Measurement... 13:06:16 Voltage Offset Correction: v_off_ini = 904.793 uV, v_off_fin = 915.331 uV 13:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.262 uVs 13:06:18 I2X Average and RMS of Measurements VT = -104.716 +- 8.419 uVs I2X = 9.634 +- 0.775 uTm^2 13:06:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:24 Integrated Voltage Measurement... 13:06:33 Voltage Offset Correction: v_off_ini = 910.259 uV, v_off_fin = 890.995 uV 13:06:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -375.571 uVs 13:06:33 Integrated Voltage Measurement... 13:06:42 Voltage Offset Correction: v_off_ini = 878.990 uV, v_off_fin = 874.844 uV 13:06:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.517 uVs 13:06:42 Integrated Voltage Measurement... 13:06:51 Voltage Offset Correction: v_off_ini = 875.369 uV, v_off_fin = 883.398 uV 13:06:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.704 uVs 13:06:51 Integrated Voltage Measurement... 13:07:00 Voltage Offset Correction: v_off_ini = 881.416 uV, v_off_fin = 877.374 uV 13:07:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.203 uVs 13:07:00 Integrated Voltage Measurement... 13:07:09 Voltage Offset Correction: v_off_ini = 879.539 uV, v_off_fin = 878.312 uV 13:07:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.560 uVs 13:07:09 Integrated Voltage Measurement... 13:07:18 Voltage Offset Correction: v_off_ini = 894.804 uV, v_off_fin = 888.541 uV 13:07:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.123 uVs 13:07:20 I2Y Average and RMS of Measurements VT = -367.946 +- 3.905 uVs I2Y = -33.851 +- 0.359 uTm^2 13:07:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:07:29 Integrated Voltage Measurement... 13:07:38 Voltage Offset Correction: v_off_ini = 886.284 uV, v_off_fin = 883.741 uV 13:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.636 uVs 13:07:38 Integrated Voltage Measurement... 13:07:47 Voltage Offset Correction: v_off_ini = 904.040 uV, v_off_fin = 892.596 uV 13:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.766 uVs 13:07:47 Integrated Voltage Measurement... 13:07:56 Voltage Offset Correction: v_off_ini = 894.967 uV, v_off_fin = 881.901 uV 13:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.978 uVs 13:07:56 Integrated Voltage Measurement... 13:08:05 Voltage Offset Correction: v_off_ini = 876.112 uV, v_off_fin = 883.421 uV 13:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.841 uVs 13:08:05 Integrated Voltage Measurement... 13:08:14 Voltage Offset Correction: v_off_ini = 886.599 uV, v_off_fin = 873.935 uV 13:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.604 uVs 13:08:14 Integrated Voltage Measurement... 13:08:23 Voltage Offset Correction: v_off_ini = 879.118 uV, v_off_fin = 881.189 uV 13:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.461 uVs 13:08:27 I1X Average and RMS of Measurements VT = -71.881 +- 9.964 uVs I1X = 14.376 +- 1.993 uTm 13:08:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:08:34 Integrated Voltage Measurement... 13:08:43 Voltage Offset Correction: v_off_ini = 873.762 uV, v_off_fin = 875.261 uV 13:08:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.057 uVs 13:08:43 Integrated Voltage Measurement... 13:08:52 Voltage Offset Correction: v_off_ini = 870.316 uV, v_off_fin = 882.120 uV 13:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.112 uVs 13:08:52 Integrated Voltage Measurement... 13:09:01 Voltage Offset Correction: v_off_ini = 872.804 uV, v_off_fin = 867.982 uV 13:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.394 uVs 13:09:01 Integrated Voltage Measurement... 13:09:10 Voltage Offset Correction: v_off_ini = 872.474 uV, v_off_fin = 878.045 uV 13:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.767 uVs 13:09:10 Integrated Voltage Measurement... 13:09:19 Voltage Offset Correction: v_off_ini = 865.231 uV, v_off_fin = 860.163 uV 13:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.322 uVs 13:09:19 Integrated Voltage Measurement... 13:09:28 Voltage Offset Correction: v_off_ini = 864.544 uV, v_off_fin = 864.817 uV 13:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.078 uVs 13:09:32 I1Y Average and RMS of Measurements VT = -217.455 +- 6.062 uVs I1Y = -43.487 +- 1.212 uTm 13:09:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:09:37 Integrated Voltage Measurement... 13:09:46 Voltage Offset Correction: v_off_ini = 845.577 uV, v_off_fin = 835.029 uV 13:09:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -100.334 uVs 13:09:46 Integrated Voltage Measurement... 13:09:55 Voltage Offset Correction: v_off_ini = 850.284 uV, v_off_fin = 855.738 uV 13:09:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.822 uVs 13:09:55 Integrated Voltage Measurement... 13:10:04 Voltage Offset Correction: v_off_ini = 848.657 uV, v_off_fin = 843.786 uV 13:10:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.653 uVs 13:10:04 Integrated Voltage Measurement... 13:10:13 Voltage Offset Correction: v_off_ini = 858.909 uV, v_off_fin = 863.391 uV 13:10:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.804 uVs 13:10:13 Integrated Voltage Measurement... 13:10:22 Voltage Offset Correction: v_off_ini = 856.308 uV, v_off_fin = 851.181 uV 13:10:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.855 uVs 13:10:23 Integrated Voltage Measurement... 13:10:32 Voltage Offset Correction: v_off_ini = 837.256 uV, v_off_fin = 853.530 uV 13:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.932 uVs 13:10:34 I2X Average and RMS of Measurements VT = -115.567 +- 4.972 uVs I2X = 10.632 +- 0.457 uTm^2 13:10:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:10:39 Integrated Voltage Measurement... 13:10:48 Voltage Offset Correction: v_off_ini = 838.381 uV, v_off_fin = 855.696 uV 13:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.221 uVs 13:10:48 Integrated Voltage Measurement... 13:10:57 Voltage Offset Correction: v_off_ini = 850.334 uV, v_off_fin = 845.424 uV 13:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.691 uVs 13:10:57 Integrated Voltage Measurement... 13:11:06 Voltage Offset Correction: v_off_ini = 850.983 uV, v_off_fin = 850.032 uV 13:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.573 uVs 13:11:06 Integrated Voltage Measurement... 13:11:15 Voltage Offset Correction: v_off_ini = 851.417 uV, v_off_fin = 852.032 uV 13:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.849 uVs 13:11:15 Integrated Voltage Measurement... 13:11:24 Voltage Offset Correction: v_off_ini = 846.471 uV, v_off_fin = 848.150 uV 13:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.627 uVs 13:11:24 Integrated Voltage Measurement... 13:11:33 Voltage Offset Correction: v_off_ini = 832.130 uV, v_off_fin = 840.217 uV 13:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.287 uVs 13:11:36 I2Y Average and RMS of Measurements VT = -360.375 +- 3.843 uVs I2Y = -33.154 +- 0.354 uTm^2 13:11:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:11:44 Integrated Voltage Measurement... 13:11:53 Voltage Offset Correction: v_off_ini = 843.289 uV, v_off_fin = 832.546 uV 13:11:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.440 uVs 13:11:53 Integrated Voltage Measurement... 13:12:02 Voltage Offset Correction: v_off_ini = 831.176 uV, v_off_fin = 835.691 uV 13:12:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.784 uVs 13:12:02 Integrated Voltage Measurement... 13:12:11 Voltage Offset Correction: v_off_ini = 837.801 uV, v_off_fin = 840.137 uV 13:12:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.532 uVs 13:12:11 Integrated Voltage Measurement... 13:12:20 Voltage Offset Correction: v_off_ini = 837.182 uV, v_off_fin = 844.281 uV 13:12:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.917 uVs 13:12:20 Integrated Voltage Measurement... 13:12:29 Voltage Offset Correction: v_off_ini = 829.533 uV, v_off_fin = 807.762 uV 13:12:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.064 uVs 13:12:29 Integrated Voltage Measurement... 13:12:38 Voltage Offset Correction: v_off_ini = 821.632 uV, v_off_fin = 831.476 uV 13:12:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.227 uVs 13:12:42 I1X Average and RMS of Measurements VT = -66.661 +- 1.620 uVs I1X = 13.332 +- 0.324 uTm 13:12:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:12:49 Integrated Voltage Measurement... 13:12:58 Voltage Offset Correction: v_off_ini = 823.857 uV, v_off_fin = 814.638 uV 13:12:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -220.532 uVs 13:12:58 Integrated Voltage Measurement... 13:13:07 Voltage Offset Correction: v_off_ini = 822.848 uV, v_off_fin = 832.282 uV 13:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.617 uVs 13:13:07 Integrated Voltage Measurement... 13:13:16 Voltage Offset Correction: v_off_ini = 826.101 uV, v_off_fin = 812.126 uV 13:13:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.858 uVs 13:13:16 Integrated Voltage Measurement... 13:13:25 Voltage Offset Correction: v_off_ini = 830.509 uV, v_off_fin = 851.639 uV 13:13:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.984 uVs 13:13:25 Integrated Voltage Measurement... 13:13:34 Voltage Offset Correction: v_off_ini = 824.917 uV, v_off_fin = 820.910 uV 13:13:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.632 uVs 13:13:34 Integrated Voltage Measurement... 13:13:43 Voltage Offset Correction: v_off_ini = 828.385 uV, v_off_fin = 843.663 uV 13:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.238 uVs 13:13:48 I1Y Average and RMS of Measurements VT = -218.810 +- 5.484 uVs I1Y = -43.763 +- 1.098 uTm 13:13:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:13:53 Integrated Voltage Measurement... 13:14:02 Voltage Offset Correction: v_off_ini = 832.113 uV, v_off_fin = 824.034 uV 13:14:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.758 uVs 13:14:02 Integrated Voltage Measurement... 13:14:11 Voltage Offset Correction: v_off_ini = 827.513 uV, v_off_fin = 836.398 uV 13:14:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.876 uVs 13:14:11 Integrated Voltage Measurement... 13:14:20 Voltage Offset Correction: v_off_ini = 837.756 uV, v_off_fin = 820.160 uV 13:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.117 uVs 13:14:20 Integrated Voltage Measurement... 13:14:29 Voltage Offset Correction: v_off_ini = 843.464 uV, v_off_fin = 853.909 uV 13:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.888 uVs 13:14:29 Integrated Voltage Measurement... 13:14:38 Voltage Offset Correction: v_off_ini = 847.667 uV, v_off_fin = 841.290 uV 13:14:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.127 uVs 13:14:38 Integrated Voltage Measurement... 13:14:47 Voltage Offset Correction: v_off_ini = 849.509 uV, v_off_fin = 846.203 uV 13:14:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.588 uVs 13:14:49 I2X Average and RMS of Measurements VT = -107.392 +- 6.300 uVs I2X = 9.880 +- 0.580 uTm^2 13:14:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:14:54 Integrated Voltage Measurement... 13:15:03 Voltage Offset Correction: v_off_ini = 844.421 uV, v_off_fin = 830.762 uV 13:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.862 uVs 13:15:04 Integrated Voltage Measurement... 13:15:13 Voltage Offset Correction: v_off_ini = 838.994 uV, v_off_fin = 841.073 uV 13:15:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.274 uVs 13:15:13 Integrated Voltage Measurement... 13:15:22 Voltage Offset Correction: v_off_ini = 852.034 uV, v_off_fin = 852.187 uV 13:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -373.968 uVs 13:15:22 Integrated Voltage Measurement... 13:15:31 Voltage Offset Correction: v_off_ini = 846.040 uV, v_off_fin = 849.829 uV 13:15:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.370 uVs 13:15:31 Integrated Voltage Measurement... 13:15:40 Voltage Offset Correction: v_off_ini = 840.483 uV, v_off_fin = 839.412 uV 13:15:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.629 uVs 13:15:40 Integrated Voltage Measurement... 13:15:49 Voltage Offset Correction: v_off_ini = 841.253 uV, v_off_fin = 834.616 uV 13:15:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.416 uVs 13:15:51 I2Y Average and RMS of Measurements VT = -368.586 +- 3.554 uVs I2Y = -33.910 +- 0.327 uTm^2 13:16:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:16:12 Integrated Voltage Measurement... 13:16:21 Voltage Offset Correction: v_off_ini = 846.061 uV, v_off_fin = 832.201 uV 13:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.149 uVs 13:16:21 Integrated Voltage Measurement... 13:16:30 Voltage Offset Correction: v_off_ini = 840.235 uV, v_off_fin = 846.774 uV 13:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 90.699 uVs 13:16:30 Integrated Voltage Measurement... 13:16:39 Voltage Offset Correction: v_off_ini = 833.957 uV, v_off_fin = 844.645 uV 13:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.363 uVs 13:16:39 Integrated Voltage Measurement... 13:16:48 Voltage Offset Correction: v_off_ini = 845.617 uV, v_off_fin = 846.838 uV 13:16:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.686 uVs 13:16:48 Integrated Voltage Measurement... 13:16:57 Voltage Offset Correction: v_off_ini = 845.872 uV, v_off_fin = 847.542 uV 13:16:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.668 uVs 13:16:57 Integrated Voltage Measurement... 13:17:06 Voltage Offset Correction: v_off_ini = 850.193 uV, v_off_fin = 854.011 uV 13:17:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.297 uVs 13:17:11 I1X Average and RMS of Measurements VT = -76.977 +- 9.615 uVs I1X = 15.396 +- 1.923 uTm 13:17:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:17:17 Integrated Voltage Measurement... 13:17:26 Voltage Offset Correction: v_off_ini = 845.309 uV, v_off_fin = 843.262 uV 13:17:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.422 uVs 13:17:27 Integrated Voltage Measurement... 13:17:35 Voltage Offset Correction: v_off_ini = 844.082 uV, v_off_fin = 859.280 uV 13:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.404 uVs 13:17:36 Integrated Voltage Measurement... 13:17:44 Voltage Offset Correction: v_off_ini = 843.893 uV, v_off_fin = 831.902 uV 13:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.504 uVs 13:17:45 Integrated Voltage Measurement... 13:17:53 Voltage Offset Correction: v_off_ini = 857.226 uV, v_off_fin = 856.481 uV 13:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.173 uVs 13:17:54 Integrated Voltage Measurement... 13:18:02 Voltage Offset Correction: v_off_ini = 845.047 uV, v_off_fin = 842.847 uV 13:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.249 uVs 13:18:03 Integrated Voltage Measurement... 13:18:12 Voltage Offset Correction: v_off_ini = 861.202 uV, v_off_fin = 863.572 uV 13:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.370 uVs 13:18:16 I1Y Average and RMS of Measurements VT = -228.020 +- 2.138 uVs I1Y = -45.604 +- 0.428 uTm 13:18:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:18:23 Integrated Voltage Measurement... 13:18:32 Voltage Offset Correction: v_off_ini = 851.984 uV, v_off_fin = 859.882 uV 13:18:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.812 uVs 13:18:33 Integrated Voltage Measurement... 13:18:42 Voltage Offset Correction: v_off_ini = 866.370 uV, v_off_fin = 869.215 uV 13:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.883 uVs 13:18:42 Integrated Voltage Measurement... 13:18:51 Voltage Offset Correction: v_off_ini = 860.009 uV, v_off_fin = 850.809 uV 13:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.966 uVs 13:18:51 Integrated Voltage Measurement... 13:19:00 Voltage Offset Correction: v_off_ini = 865.331 uV, v_off_fin = 872.353 uV 13:19:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.310 uVs 13:19:00 Integrated Voltage Measurement... 13:19:09 Voltage Offset Correction: v_off_ini = 860.338 uV, v_off_fin = 849.129 uV 13:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.965 uVs 13:19:09 Integrated Voltage Measurement... 13:19:18 Voltage Offset Correction: v_off_ini = 866.199 uV, v_off_fin = 875.954 uV 13:19:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.992 uVs 13:19:20 I2X Average and RMS of Measurements VT = -99.322 +- 5.622 uVs I2X = 9.138 +- 0.517 uTm^2 13:19:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:19:28 Integrated Voltage Measurement... 13:19:37 Voltage Offset Correction: v_off_ini = 859.962 uV, v_off_fin = 863.136 uV 13:19:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.424 uVs 13:19:37 Integrated Voltage Measurement... 13:19:46 Voltage Offset Correction: v_off_ini = 863.651 uV, v_off_fin = 865.152 uV 13:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.651 uVs 13:19:46 Integrated Voltage Measurement... 13:19:55 Voltage Offset Correction: v_off_ini = 871.778 uV, v_off_fin = 856.476 uV 13:19:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -392.246 uVs 13:19:55 Integrated Voltage Measurement... 13:20:04 Voltage Offset Correction: v_off_ini = 855.630 uV, v_off_fin = 850.701 uV 13:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.742 uVs 13:20:04 Integrated Voltage Measurement... 13:20:13 Voltage Offset Correction: v_off_ini = 849.784 uV, v_off_fin = 849.644 uV 13:20:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -363.025 uVs 13:20:13 Integrated Voltage Measurement... 13:20:22 Voltage Offset Correction: v_off_ini = 852.826 uV, v_off_fin = 840.161 uV 13:20:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.719 uVs 13:20:25 I2Y Average and RMS of Measurements VT = -369.301 +- 7.561 uVs I2Y = -33.976 +- 0.696 uTm^2 13:20:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:20:33 Integrated Voltage Measurement... 13:20:42 Voltage Offset Correction: v_off_ini = 853.234 uV, v_off_fin = 851.247 uV 13:20:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.216 uVs 13:20:43 Integrated Voltage Measurement... 13:20:51 Voltage Offset Correction: v_off_ini = 853.751 uV, v_off_fin = 850.691 uV 13:20:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.067 uVs 13:20:52 Integrated Voltage Measurement... 13:21:01 Voltage Offset Correction: v_off_ini = 841.418 uV, v_off_fin = 831.139 uV 13:21:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.918 uVs 13:21:01 Integrated Voltage Measurement... 13:21:10 Voltage Offset Correction: v_off_ini = 842.024 uV, v_off_fin = 852.924 uV 13:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.795 uVs 13:21:10 Integrated Voltage Measurement... 13:21:19 Voltage Offset Correction: v_off_ini = 839.219 uV, v_off_fin = 843.479 uV 13:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.094 uVs 13:21:19 Integrated Voltage Measurement... 13:21:28 Voltage Offset Correction: v_off_ini = 842.353 uV, v_off_fin = 844.571 uV 13:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.134 uVs 13:21:32 I1X Average and RMS of Measurements VT = -73.038 +- 4.831 uVs I1X = 14.608 +- 0.966 uTm 13:21:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:21:39 Integrated Voltage Measurement... 13:21:47 Voltage Offset Correction: v_off_ini = 838.787 uV, v_off_fin = 834.894 uV 13:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.259 uVs 13:21:48 Integrated Voltage Measurement... 13:21:56 Voltage Offset Correction: v_off_ini = 849.349 uV, v_off_fin = 845.229 uV 13:21:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.304 uVs 13:21:57 Integrated Voltage Measurement... 13:22:05 Voltage Offset Correction: v_off_ini = 837.984 uV, v_off_fin = 827.474 uV 13:22:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.740 uVs 13:22:06 Integrated Voltage Measurement... 13:22:14 Voltage Offset Correction: v_off_ini = 839.696 uV, v_off_fin = 845.319 uV 13:22:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.598 uVs 13:22:15 Integrated Voltage Measurement... 13:22:23 Voltage Offset Correction: v_off_ini = 844.310 uV, v_off_fin = 826.196 uV 13:22:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.696 uVs 13:22:24 Integrated Voltage Measurement... 13:22:32 Voltage Offset Correction: v_off_ini = 829.451 uV, v_off_fin = 848.179 uV 13:22:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.806 uVs 13:22:37 I1Y Average and RMS of Measurements VT = -221.734 +- 0.851 uVs I1Y = -44.347 +- 0.170 uTm 13:22:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:22:44 Integrated Voltage Measurement... 13:22:53 Voltage Offset Correction: v_off_ini = 819.615 uV, v_off_fin = 821.290 uV 13:22:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.942 uVs 13:22:53 Integrated Voltage Measurement... 13:23:02 Voltage Offset Correction: v_off_ini = 824.059 uV, v_off_fin = 826.857 uV 13:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.848 uVs 13:23:03 Integrated Voltage Measurement... 13:23:11 Voltage Offset Correction: v_off_ini = 815.882 uV, v_off_fin = 817.055 uV 13:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.013 uVs 13:23:12 Integrated Voltage Measurement... 13:23:21 Voltage Offset Correction: v_off_ini = 820.389 uV, v_off_fin = 840.661 uV 13:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.288 uVs 13:23:21 Integrated Voltage Measurement... 13:23:30 Voltage Offset Correction: v_off_ini = 839.186 uV, v_off_fin = 826.757 uV 13:23:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.815 uVs 13:23:30 Integrated Voltage Measurement... 13:23:39 Voltage Offset Correction: v_off_ini = 823.993 uV, v_off_fin = 836.122 uV 13:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.280 uVs 13:23:41 I2X Average and RMS of Measurements VT = -100.531 +- 3.237 uVs I2X = 9.249 +- 0.298 uTm^2 13:23:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:23:49 Integrated Voltage Measurement... 13:23:58 Voltage Offset Correction: v_off_ini = 822.790 uV, v_off_fin = 829.410 uV 13:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.249 uVs 13:23:58 Integrated Voltage Measurement... 13:24:07 Voltage Offset Correction: v_off_ini = 820.395 uV, v_off_fin = 817.013 uV 13:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.898 uVs 13:24:07 Integrated Voltage Measurement... 13:24:16 Voltage Offset Correction: v_off_ini = 828.307 uV, v_off_fin = 833.194 uV 13:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.804 uVs 13:24:16 Integrated Voltage Measurement... 13:24:25 Voltage Offset Correction: v_off_ini = 835.806 uV, v_off_fin = 833.872 uV 13:24:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 357.539 uVs 13:24:25 Integrated Voltage Measurement... 13:24:34 Voltage Offset Correction: v_off_ini = 825.870 uV, v_off_fin = 821.199 uV 13:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -350.410 uVs 13:24:34 Integrated Voltage Measurement... 13:24:43 Voltage Offset Correction: v_off_ini = 826.413 uV, v_off_fin = 837.456 uV 13:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.055 uVs 13:24:45 I2Y Average and RMS of Measurements VT = -352.492 +- 4.608 uVs I2Y = -32.430 +- 0.424 uTm^2 13:24:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:54 Integrated Voltage Measurement... 13:25:03 Voltage Offset Correction: v_off_ini = 827.168 uV, v_off_fin = 821.179 uV 13:25:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.904 uVs 13:25:03 Integrated Voltage Measurement... 13:25:12 Voltage Offset Correction: v_off_ini = 822.434 uV, v_off_fin = 827.758 uV 13:25:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.323 uVs 13:25:12 Integrated Voltage Measurement... 13:25:21 Voltage Offset Correction: v_off_ini = 821.935 uV, v_off_fin = 826.577 uV 13:25:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.789 uVs 13:25:21 Integrated Voltage Measurement... 13:25:30 Voltage Offset Correction: v_off_ini = 820.087 uV, v_off_fin = 826.363 uV 13:25:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.018 uVs 13:25:30 Integrated Voltage Measurement... 13:25:39 Voltage Offset Correction: v_off_ini = 823.933 uV, v_off_fin = 817.041 uV 13:25:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.581 uVs 13:25:39 Integrated Voltage Measurement... 13:25:48 Voltage Offset Correction: v_off_ini = 827.993 uV, v_off_fin = 823.748 uV 13:25:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.508 uVs 13:25:52 I1X Average and RMS of Measurements VT = -68.854 +- 3.943 uVs I1X = 13.771 +- 0.789 uTm 13:25:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:59 Integrated Voltage Measurement... 13:26:08 Voltage Offset Correction: v_off_ini = 828.558 uV, v_off_fin = 808.082 uV 13:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.059 uVs 13:26:08 Integrated Voltage Measurement... 13:26:17 Voltage Offset Correction: v_off_ini = 820.885 uV, v_off_fin = 826.276 uV 13:26:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.013 uVs 13:26:17 Integrated Voltage Measurement... 13:26:26 Voltage Offset Correction: v_off_ini = 812.386 uV, v_off_fin = 804.379 uV 13:26:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.669 uVs 13:26:26 Integrated Voltage Measurement... 13:26:35 Voltage Offset Correction: v_off_ini = 818.454 uV, v_off_fin = 827.041 uV 13:26:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.732 uVs 13:26:35 Integrated Voltage Measurement... 13:26:44 Voltage Offset Correction: v_off_ini = 833.645 uV, v_off_fin = 810.618 uV 13:26:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.745 uVs 13:26:44 Integrated Voltage Measurement... 13:26:53 Voltage Offset Correction: v_off_ini = 824.703 uV, v_off_fin = 834.372 uV 13:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.664 uVs 13:26:57 I1Y Average and RMS of Measurements VT = -220.647 +- 2.041 uVs I1Y = -44.129 +- 0.408 uTm 13:27:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:05 Integrated Voltage Measurement... 13:27:14 Voltage Offset Correction: v_off_ini = 789.405 uV, v_off_fin = 789.741 uV 13:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.038 uVs 13:27:14 Integrated Voltage Measurement... 13:27:23 Voltage Offset Correction: v_off_ini = 804.512 uV, v_off_fin = 810.899 uV 13:27:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.824 uVs 13:27:23 Integrated Voltage Measurement... 13:27:32 Voltage Offset Correction: v_off_ini = 803.108 uV, v_off_fin = 802.692 uV 13:27:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.548 uVs 13:27:32 Integrated Voltage Measurement... 13:27:41 Voltage Offset Correction: v_off_ini = 804.992 uV, v_off_fin = 821.934 uV 13:27:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.014 uVs 13:27:41 Integrated Voltage Measurement... 13:27:50 Voltage Offset Correction: v_off_ini = 814.125 uV, v_off_fin = 797.160 uV 13:27:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.863 uVs 13:27:50 Integrated Voltage Measurement... 13:27:59 Voltage Offset Correction: v_off_ini = 809.411 uV, v_off_fin = 818.963 uV 13:27:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.816 uVs 13:28:02 I2X Average and RMS of Measurements VT = -92.017 +- 3.479 uVs I2X = 8.466 +- 0.320 uTm^2 13:28:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:09 Integrated Voltage Measurement... 13:28:18 Voltage Offset Correction: v_off_ini = 805.264 uV, v_off_fin = 809.232 uV 13:28:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.293 uVs 13:28:18 Integrated Voltage Measurement... 13:28:27 Voltage Offset Correction: v_off_ini = 814.638 uV, v_off_fin = 807.545 uV 13:28:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.512 uVs 13:28:27 Integrated Voltage Measurement... 13:28:36 Voltage Offset Correction: v_off_ini = 817.558 uV, v_off_fin = 822.853 uV 13:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.049 uVs 13:28:36 Integrated Voltage Measurement... 13:28:45 Voltage Offset Correction: v_off_ini = 813.880 uV, v_off_fin = 815.075 uV 13:28:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.628 uVs 13:28:46 Integrated Voltage Measurement... 13:28:54 Voltage Offset Correction: v_off_ini = 819.702 uV, v_off_fin = 818.092 uV 13:28:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.106 uVs 13:28:55 Integrated Voltage Measurement... 13:29:04 Voltage Offset Correction: v_off_ini = 828.707 uV, v_off_fin = 821.547 uV 13:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.763 uVs 13:29:06 I2Y Average and RMS of Measurements VT = -347.725 +- 6.368 uVs I2Y = -31.991 +- 0.586 uTm^2 13:29:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:29:15 Integrated Voltage Measurement... 13:29:24 Voltage Offset Correction: v_off_ini = 807.666 uV, v_off_fin = 793.726 uV 13:29:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.630 uVs 13:29:24 Integrated Voltage Measurement... 13:29:33 Voltage Offset Correction: v_off_ini = 808.218 uV, v_off_fin = 811.435 uV 13:29:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.769 uVs 13:29:33 Integrated Voltage Measurement... 13:29:42 Voltage Offset Correction: v_off_ini = 793.061 uV, v_off_fin = 795.127 uV 13:29:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.657 uVs 13:29:42 Integrated Voltage Measurement... 13:29:51 Voltage Offset Correction: v_off_ini = 801.795 uV, v_off_fin = 799.452 uV 13:29:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.146 uVs 13:29:51 Integrated Voltage Measurement... 13:30:00 Voltage Offset Correction: v_off_ini = 805.147 uV, v_off_fin = 798.793 uV 13:30:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.226 uVs 13:30:00 Integrated Voltage Measurement... 13:30:09 Voltage Offset Correction: v_off_ini = 796.094 uV, v_off_fin = 805.602 uV 13:30:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.000 uVs 13:30:13 I1X Average and RMS of Measurements VT = -60.905 +- 5.668 uVs I1X = 12.181 +- 1.133 uTm 13:30:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:30:20 Integrated Voltage Measurement... 13:30:29 Voltage Offset Correction: v_off_ini = 797.532 uV, v_off_fin = 789.979 uV 13:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -195.586 uVs 13:30:29 Integrated Voltage Measurement... 13:30:38 Voltage Offset Correction: v_off_ini = 801.952 uV, v_off_fin = 802.558 uV 13:30:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.041 uVs 13:30:38 Integrated Voltage Measurement... 13:30:47 Voltage Offset Correction: v_off_ini = 805.072 uV, v_off_fin = 787.529 uV 13:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.018 uVs 13:30:47 Integrated Voltage Measurement... 13:30:56 Voltage Offset Correction: v_off_ini = 786.900 uV, v_off_fin = 802.359 uV 13:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.539 uVs 13:30:56 Integrated Voltage Measurement... 13:31:05 Voltage Offset Correction: v_off_ini = 803.031 uV, v_off_fin = 782.125 uV 13:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.130 uVs 13:31:05 Integrated Voltage Measurement... 13:31:14 Voltage Offset Correction: v_off_ini = 797.217 uV, v_off_fin = 796.936 uV 13:31:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.745 uVs 13:31:18 I1Y Average and RMS of Measurements VT = -208.010 +- 11.311 uVs I1Y = -41.603 +- 2.261 uTm 13:31:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:31:26 Integrated Voltage Measurement... 13:31:35 Voltage Offset Correction: v_off_ini = 787.334 uV, v_off_fin = 793.294 uV 13:31:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.235 uVs 13:31:35 Integrated Voltage Measurement... 13:31:44 Voltage Offset Correction: v_off_ini = 798.867 uV, v_off_fin = 809.114 uV 13:31:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.450 uVs 13:31:44 Integrated Voltage Measurement... 13:31:53 Voltage Offset Correction: v_off_ini = 797.444 uV, v_off_fin = 782.043 uV 13:31:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.582 uVs 13:31:53 Integrated Voltage Measurement... 13:32:02 Voltage Offset Correction: v_off_ini = 797.971 uV, v_off_fin = 804.971 uV 13:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.331 uVs 13:32:02 Integrated Voltage Measurement... 13:32:11 Voltage Offset Correction: v_off_ini = 784.469 uV, v_off_fin = 783.961 uV 13:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.315 uVs 13:32:11 Integrated Voltage Measurement... 13:32:20 Voltage Offset Correction: v_off_ini = 789.674 uV, v_off_fin = 792.332 uV 13:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.439 uVs 13:32:22 I2X Average and RMS of Measurements VT = -93.059 +- 5.900 uVs I2X = 8.561 +- 0.543 uTm^2 13:32:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:32:30 Integrated Voltage Measurement... 13:32:39 Voltage Offset Correction: v_off_ini = 780.314 uV, v_off_fin = 779.448 uV 13:32:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.874 uVs 13:32:39 Integrated Voltage Measurement... 13:32:48 Voltage Offset Correction: v_off_ini = 783.351 uV, v_off_fin = 787.054 uV 13:32:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.174 uVs 13:32:48 Integrated Voltage Measurement... 13:32:57 Voltage Offset Correction: v_off_ini = 777.826 uV, v_off_fin = 782.195 uV 13:32:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.492 uVs 13:32:57 Integrated Voltage Measurement... 13:33:06 Voltage Offset Correction: v_off_ini = 770.531 uV, v_off_fin = 782.984 uV 13:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.447 uVs 13:33:06 Integrated Voltage Measurement... 13:33:15 Voltage Offset Correction: v_off_ini = 784.703 uV, v_off_fin = 781.984 uV 13:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.410 uVs 13:33:15 Integrated Voltage Measurement... 13:33:24 Voltage Offset Correction: v_off_ini = 789.588 uV, v_off_fin = 785.773 uV 13:33:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.237 uVs 13:33:27 I2Y Average and RMS of Measurements VT = -339.106 +- 2.045 uVs I2Y = -31.198 +- 0.188 uTm^2 13:33:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:33:35 Integrated Voltage Measurement... 13:33:44 Voltage Offset Correction: v_off_ini = 783.390 uV, v_off_fin = 774.442 uV 13:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.507 uVs 13:33:44 Integrated Voltage Measurement... 13:33:53 Voltage Offset Correction: v_off_ini = 784.730 uV, v_off_fin = 786.503 uV 13:33:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.709 uVs 13:33:54 Integrated Voltage Measurement... 13:34:02 Voltage Offset Correction: v_off_ini = 775.409 uV, v_off_fin = 780.426 uV 13:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.348 uVs 13:34:03 Integrated Voltage Measurement... 13:34:11 Voltage Offset Correction: v_off_ini = 783.274 uV, v_off_fin = 791.614 uV 13:34:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.896 uVs 13:34:12 Integrated Voltage Measurement... 13:34:21 Voltage Offset Correction: v_off_ini = 778.662 uV, v_off_fin = 778.409 uV 13:34:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.600 uVs 13:34:21 Integrated Voltage Measurement... 13:34:30 Voltage Offset Correction: v_off_ini = 789.764 uV, v_off_fin = 791.939 uV 13:34:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.017 uVs 13:34:34 I1X Average and RMS of Measurements VT = -56.846 +- 6.740 uVs I1X = 11.369 +- 1.348 uTm 13:34:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:34:41 Integrated Voltage Measurement... 13:34:49 Voltage Offset Correction: v_off_ini = 792.583 uV, v_off_fin = 774.936 uV 13:34:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.864 uVs 13:34:50 Integrated Voltage Measurement... 13:34:58 Voltage Offset Correction: v_off_ini = 784.929 uV, v_off_fin = 794.597 uV 13:34:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.122 uVs 13:34:59 Integrated Voltage Measurement... 13:35:07 Voltage Offset Correction: v_off_ini = 767.879 uV, v_off_fin = 759.992 uV 13:35:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.843 uVs 13:35:08 Integrated Voltage Measurement... 13:35:16 Voltage Offset Correction: v_off_ini = 780.950 uV, v_off_fin = 789.362 uV 13:35:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.466 uVs 13:35:17 Integrated Voltage Measurement... 13:35:25 Voltage Offset Correction: v_off_ini = 785.418 uV, v_off_fin = 771.316 uV 13:35:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.547 uVs 13:35:26 Integrated Voltage Measurement... 13:35:34 Voltage Offset Correction: v_off_ini = 785.155 uV, v_off_fin = 807.908 uV 13:35:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.759 uVs 13:35:39 I1Y Average and RMS of Measurements VT = -208.933 +- 3.206 uVs I1Y = -41.787 +- 0.641 uTm 13:35:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:35:46 Integrated Voltage Measurement... 13:35:55 Voltage Offset Correction: v_off_ini = 771.404 uV, v_off_fin = 769.223 uV 13:35:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.443 uVs 13:35:55 Integrated Voltage Measurement... 13:36:04 Voltage Offset Correction: v_off_ini = 778.548 uV, v_off_fin = 798.103 uV 13:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.476 uVs 13:36:04 Integrated Voltage Measurement... 13:36:13 Voltage Offset Correction: v_off_ini = 782.075 uV, v_off_fin = 785.292 uV 13:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.893 uVs 13:36:13 Integrated Voltage Measurement... 13:36:22 Voltage Offset Correction: v_off_ini = 786.917 uV, v_off_fin = 790.370 uV 13:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.623 uVs 13:36:23 Integrated Voltage Measurement... 13:36:31 Voltage Offset Correction: v_off_ini = 786.538 uV, v_off_fin = 781.509 uV 13:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.891 uVs 13:36:32 Integrated Voltage Measurement... 13:36:41 Voltage Offset Correction: v_off_ini = 788.889 uV, v_off_fin = 789.097 uV 13:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.974 uVs 13:36:43 I2X Average and RMS of Measurements VT = -89.883 +- 4.340 uVs I2X = 8.269 +- 0.399 uTm^2 13:36:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:36:51 Integrated Voltage Measurement... 13:37:00 Voltage Offset Correction: v_off_ini = 785.959 uV, v_off_fin = 776.065 uV 13:37:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.448 uVs 13:37:00 Integrated Voltage Measurement... 13:37:09 Voltage Offset Correction: v_off_ini = 795.038 uV, v_off_fin = 789.722 uV 13:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.896 uVs 13:37:09 Integrated Voltage Measurement... 13:37:18 Voltage Offset Correction: v_off_ini = 778.129 uV, v_off_fin = 781.805 uV 13:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.285 uVs 13:37:18 Integrated Voltage Measurement... 13:37:27 Voltage Offset Correction: v_off_ini = 788.015 uV, v_off_fin = 775.556 uV 13:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.804 uVs 13:37:27 Integrated Voltage Measurement... 13:37:36 Voltage Offset Correction: v_off_ini = 778.561 uV, v_off_fin = 770.856 uV 13:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.761 uVs 13:37:36 Integrated Voltage Measurement... 13:37:45 Voltage Offset Correction: v_off_ini = 787.378 uV, v_off_fin = 779.631 uV 13:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.611 uVs 13:37:47 I2Y Average and RMS of Measurements VT = -337.468 +- 2.552 uVs I2Y = -31.047 +- 0.235 uTm^2 13:37:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:37:59 Integrated Voltage Measurement... 13:38:08 Voltage Offset Correction: v_off_ini = 776.026 uV, v_off_fin = 765.023 uV 13:38:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.840 uVs 13:38:08 Integrated Voltage Measurement... 13:38:17 Voltage Offset Correction: v_off_ini = 769.091 uV, v_off_fin = 756.307 uV 13:38:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.609 uVs 13:38:17 Integrated Voltage Measurement... 13:38:26 Voltage Offset Correction: v_off_ini = 768.382 uV, v_off_fin = 757.002 uV 13:38:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.682 uVs 13:38:26 Integrated Voltage Measurement... 13:38:35 Voltage Offset Correction: v_off_ini = 760.519 uV, v_off_fin = 766.157 uV 13:38:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.494 uVs 13:38:35 Integrated Voltage Measurement... 13:38:44 Voltage Offset Correction: v_off_ini = 757.125 uV, v_off_fin = 759.338 uV 13:38:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.348 uVs 13:38:44 Integrated Voltage Measurement... 13:38:53 Voltage Offset Correction: v_off_ini = 745.552 uV, v_off_fin = 762.177 uV 13:38:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 54.759 uVs 13:38:57 I1X Average and RMS of Measurements VT = -55.455 +- 2.394 uVs I1X = 11.091 +- 0.479 uTm 13:39:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:39:04 Integrated Voltage Measurement... 13:39:13 Voltage Offset Correction: v_off_ini = 764.070 uV, v_off_fin = 756.219 uV 13:39:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.229 uVs 13:39:13 Integrated Voltage Measurement... 13:39:22 Voltage Offset Correction: v_off_ini = 766.565 uV, v_off_fin = 782.334 uV 13:39:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.301 uVs 13:39:22 Integrated Voltage Measurement... 13:39:31 Voltage Offset Correction: v_off_ini = 755.999 uV, v_off_fin = 755.941 uV 13:39:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.172 uVs 13:39:31 Integrated Voltage Measurement... 13:39:40 Voltage Offset Correction: v_off_ini = 768.264 uV, v_off_fin = 782.569 uV 13:39:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.079 uVs 13:39:40 Integrated Voltage Measurement... 13:39:49 Voltage Offset Correction: v_off_ini = 769.454 uV, v_off_fin = 761.020 uV 13:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.354 uVs 13:39:49 Integrated Voltage Measurement... 13:39:58 Voltage Offset Correction: v_off_ini = 774.663 uV, v_off_fin = 767.417 uV 13:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.214 uVs 13:40:02 I1Y Average and RMS of Measurements VT = -220.558 +- 3.360 uVs I1Y = -44.112 +- 0.672 uTm 13:40:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:40:08 Integrated Voltage Measurement... 13:40:17 Voltage Offset Correction: v_off_ini = 768.654 uV, v_off_fin = 761.073 uV 13:40:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.262 uVs 13:40:17 Integrated Voltage Measurement... 13:40:26 Voltage Offset Correction: v_off_ini = 760.956 uV, v_off_fin = 776.010 uV 13:40:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.711 uVs 13:40:26 Integrated Voltage Measurement... 13:40:35 Voltage Offset Correction: v_off_ini = 764.838 uV, v_off_fin = 764.570 uV 13:40:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.177 uVs 13:40:35 Integrated Voltage Measurement... 13:40:44 Voltage Offset Correction: v_off_ini = 773.959 uV, v_off_fin = 781.192 uV 13:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.352 uVs 13:40:44 Integrated Voltage Measurement... 13:40:53 Voltage Offset Correction: v_off_ini = 768.728 uV, v_off_fin = 762.203 uV 13:40:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.089 uVs 13:40:53 Integrated Voltage Measurement... 13:41:02 Voltage Offset Correction: v_off_ini = 781.750 uV, v_off_fin = 770.466 uV 13:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.345 uVs 13:41:04 I2X Average and RMS of Measurements VT = -81.323 +- 4.754 uVs I2X = 7.482 +- 0.438 uTm^2 13:41:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:41:09 Integrated Voltage Measurement... 13:41:18 Voltage Offset Correction: v_off_ini = 769.313 uV, v_off_fin = 769.562 uV 13:41:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.833 uVs 13:41:18 Integrated Voltage Measurement... 13:41:27 Voltage Offset Correction: v_off_ini = 772.528 uV, v_off_fin = 768.924 uV 13:41:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.389 uVs 13:41:28 Integrated Voltage Measurement... 13:41:37 Voltage Offset Correction: v_off_ini = 771.851 uV, v_off_fin = 774.394 uV 13:41:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.409 uVs 13:41:37 Integrated Voltage Measurement... 13:41:46 Voltage Offset Correction: v_off_ini = 777.215 uV, v_off_fin = 776.625 uV 13:41:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.156 uVs 13:41:46 Integrated Voltage Measurement... 13:41:55 Voltage Offset Correction: v_off_ini = 779.677 uV, v_off_fin = 779.525 uV 13:41:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.558 uVs 13:41:55 Integrated Voltage Measurement... 13:42:04 Voltage Offset Correction: v_off_ini = 768.761 uV, v_off_fin = 776.297 uV 13:42:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 366.829 uVs 13:42:06 I2Y Average and RMS of Measurements VT = -351.195 +- 4.992 uVs I2Y = -32.310 +- 0.459 uTm^2 13:42:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:42:14 Integrated Voltage Measurement... 13:42:23 Voltage Offset Correction: v_off_ini = 774.950 uV, v_off_fin = 774.350 uV 13:42:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -68.396 uVs 13:42:23 Integrated Voltage Measurement... 13:42:32 Voltage Offset Correction: v_off_ini = 758.001 uV, v_off_fin = 767.031 uV 13:42:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.582 uVs 13:42:33 Integrated Voltage Measurement... 13:42:41 Voltage Offset Correction: v_off_ini = 761.730 uV, v_off_fin = 747.487 uV 13:42:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.541 uVs 13:42:42 Integrated Voltage Measurement... 13:42:51 Voltage Offset Correction: v_off_ini = 767.110 uV, v_off_fin = 783.286 uV 13:42:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.815 uVs 13:42:51 Integrated Voltage Measurement... 13:43:00 Voltage Offset Correction: v_off_ini = 768.211 uV, v_off_fin = 767.098 uV 13:43:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.640 uVs 13:43:00 Integrated Voltage Measurement... 13:43:09 Voltage Offset Correction: v_off_ini = 776.473 uV, v_off_fin = 777.269 uV 13:43:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.907 uVs 13:43:13 I1X Average and RMS of Measurements VT = -61.980 +- 8.945 uVs I1X = 12.396 +- 1.789 uTm 13:43:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:43:20 Integrated Voltage Measurement... 13:43:29 Voltage Offset Correction: v_off_ini = 774.836 uV, v_off_fin = 753.779 uV 13:43:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.722 uVs 13:43:29 Integrated Voltage Measurement... 13:43:38 Voltage Offset Correction: v_off_ini = 762.398 uV, v_off_fin = 775.514 uV 13:43:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.620 uVs 13:43:38 Integrated Voltage Measurement... 13:43:47 Voltage Offset Correction: v_off_ini = 776.886 uV, v_off_fin = 762.079 uV 13:43:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.870 uVs 13:43:47 Integrated Voltage Measurement... 13:43:56 Voltage Offset Correction: v_off_ini = 763.906 uV, v_off_fin = 777.426 uV 13:43:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.755 uVs 13:43:56 Integrated Voltage Measurement... 13:44:05 Voltage Offset Correction: v_off_ini = 750.763 uV, v_off_fin = 746.295 uV 13:44:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.643 uVs 13:44:05 Integrated Voltage Measurement... 13:44:14 Voltage Offset Correction: v_off_ini = 768.914 uV, v_off_fin = 784.459 uV 13:44:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.931 uVs 13:44:18 I1Y Average and RMS of Measurements VT = -224.257 +- 3.580 uVs I1Y = -44.851 +- 0.716 uTm 13:44:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:44:23 Integrated Voltage Measurement... 13:44:32 Voltage Offset Correction: v_off_ini = 772.164 uV, v_off_fin = 765.970 uV 13:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.706 uVs 13:44:32 Integrated Voltage Measurement... 13:44:41 Voltage Offset Correction: v_off_ini = 774.842 uV, v_off_fin = 774.249 uV 13:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.184 uVs 13:44:41 Integrated Voltage Measurement... 13:44:50 Voltage Offset Correction: v_off_ini = 774.907 uV, v_off_fin = 773.206 uV 13:44:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.088 uVs 13:44:50 Integrated Voltage Measurement... 13:44:59 Voltage Offset Correction: v_off_ini = 764.551 uV, v_off_fin = 779.853 uV 13:44:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.345 uVs 13:44:59 Integrated Voltage Measurement... 13:45:08 Voltage Offset Correction: v_off_ini = 770.648 uV, v_off_fin = 754.748 uV 13:45:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -88.536 uVs 13:45:08 Integrated Voltage Measurement... 13:45:17 Voltage Offset Correction: v_off_ini = 779.751 uV, v_off_fin = 782.864 uV 13:45:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.926 uVs 13:45:20 I2X Average and RMS of Measurements VT = -95.798 +- 8.775 uVs I2X = 8.814 +- 0.807 uTm^2 13:45:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:45:25 Integrated Voltage Measurement... 13:45:34 Voltage Offset Correction: v_off_ini = 764.655 uV, v_off_fin = 772.491 uV 13:45:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -350.223 uVs 13:45:34 Integrated Voltage Measurement... 13:45:43 Voltage Offset Correction: v_off_ini = 786.143 uV, v_off_fin = 775.415 uV 13:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 358.427 uVs 13:45:43 Integrated Voltage Measurement... 13:45:52 Voltage Offset Correction: v_off_ini = 771.978 uV, v_off_fin = 777.944 uV 13:45:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.750 uVs 13:45:52 Integrated Voltage Measurement... 13:46:01 Voltage Offset Correction: v_off_ini = 797.629 uV, v_off_fin = 779.635 uV 13:46:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.721 uVs 13:46:01 Integrated Voltage Measurement... 13:46:10 Voltage Offset Correction: v_off_ini = 775.613 uV, v_off_fin = 775.141 uV 13:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.494 uVs 13:46:10 Integrated Voltage Measurement... 13:46:19 Voltage Offset Correction: v_off_ini = 768.893 uV, v_off_fin = 758.459 uV 13:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 373.387 uVs 13:46:21 I2Y Average and RMS of Measurements VT = -356.667 +- 3.231 uVs I2Y = -32.813 +- 0.297 uTm^2 13:46:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:30 Integrated Voltage Measurement... 13:46:39 Voltage Offset Correction: v_off_ini = 777.390 uV, v_off_fin = 758.955 uV 13:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.498 uVs 13:46:39 Integrated Voltage Measurement... 13:46:48 Voltage Offset Correction: v_off_ini = 745.212 uV, v_off_fin = 750.870 uV 13:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.703 uVs 13:46:48 Integrated Voltage Measurement... 13:46:57 Voltage Offset Correction: v_off_ini = 752.962 uV, v_off_fin = 747.101 uV 13:46:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.185 uVs 13:46:57 Integrated Voltage Measurement... 13:47:06 Voltage Offset Correction: v_off_ini = 741.075 uV, v_off_fin = 754.613 uV 13:47:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.857 uVs 13:47:06 Integrated Voltage Measurement... 13:47:15 Voltage Offset Correction: v_off_ini = 742.822 uV, v_off_fin = 742.034 uV 13:47:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.449 uVs 13:47:15 Integrated Voltage Measurement... 13:47:24 Voltage Offset Correction: v_off_ini = 757.661 uV, v_off_fin = 743.622 uV 13:47:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.205 uVs 13:47:28 I1X Average and RMS of Measurements VT = -66.483 +- 4.533 uVs I1X = 13.297 +- 0.907 uTm 13:47:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:35 Integrated Voltage Measurement... 13:47:44 Voltage Offset Correction: v_off_ini = 746.133 uV, v_off_fin = 718.683 uV 13:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.059 uVs 13:47:44 Integrated Voltage Measurement... 13:47:53 Voltage Offset Correction: v_off_ini = 729.802 uV, v_off_fin = 738.764 uV 13:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.155 uVs 13:47:53 Integrated Voltage Measurement... 13:48:02 Voltage Offset Correction: v_off_ini = 730.460 uV, v_off_fin = 723.494 uV 13:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.390 uVs 13:48:02 Integrated Voltage Measurement... 13:48:11 Voltage Offset Correction: v_off_ini = 738.117 uV, v_off_fin = 741.083 uV 13:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.092 uVs 13:48:11 Integrated Voltage Measurement... 13:48:20 Voltage Offset Correction: v_off_ini = 732.555 uV, v_off_fin = 722.700 uV 13:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.993 uVs 13:48:20 Integrated Voltage Measurement... 13:48:29 Voltage Offset Correction: v_off_ini = 734.348 uV, v_off_fin = 739.952 uV 13:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.866 uVs 13:48:33 I1Y Average and RMS of Measurements VT = -213.426 +- 4.164 uVs I1Y = -42.684 +- 0.833 uTm 13:48:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:38 Integrated Voltage Measurement... 13:48:47 Voltage Offset Correction: v_off_ini = 748.672 uV, v_off_fin = 734.526 uV 13:48:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.096 uVs 13:48:47 Integrated Voltage Measurement... 13:48:56 Voltage Offset Correction: v_off_ini = 741.751 uV, v_off_fin = 750.555 uV 13:48:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.279 uVs 13:48:56 Integrated Voltage Measurement... 13:49:05 Voltage Offset Correction: v_off_ini = 743.839 uV, v_off_fin = 737.242 uV 13:49:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.983 uVs 13:49:05 Integrated Voltage Measurement... 13:49:14 Voltage Offset Correction: v_off_ini = 731.152 uV, v_off_fin = 739.495 uV 13:49:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.809 uVs 13:49:14 Integrated Voltage Measurement... 13:49:23 Voltage Offset Correction: v_off_ini = 729.430 uV, v_off_fin = 722.853 uV 13:49:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.747 uVs 13:49:24 Integrated Voltage Measurement... 13:49:33 Voltage Offset Correction: v_off_ini = 731.980 uV, v_off_fin = 745.257 uV 13:49:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.490 uVs 13:49:35 I2X Average and RMS of Measurements VT = -93.067 +- 5.106 uVs I2X = 8.562 +- 0.470 uTm^2 13:49:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:40 Integrated Voltage Measurement... 13:49:49 Voltage Offset Correction: v_off_ini = 721.645 uV, v_off_fin = 711.439 uV 13:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.925 uVs 13:49:49 Integrated Voltage Measurement... 13:49:58 Voltage Offset Correction: v_off_ini = 704.711 uV, v_off_fin = 708.057 uV 13:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.313 uVs 13:49:58 Integrated Voltage Measurement... 13:50:07 Voltage Offset Correction: v_off_ini = 705.183 uV, v_off_fin = 703.964 uV 13:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.254 uVs 13:50:07 Integrated Voltage Measurement... 13:50:16 Voltage Offset Correction: v_off_ini = 716.518 uV, v_off_fin = 719.277 uV 13:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.565 uVs 13:50:16 Integrated Voltage Measurement... 13:50:25 Voltage Offset Correction: v_off_ini = 715.625 uV, v_off_fin = 713.058 uV 13:50:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.968 uVs 13:50:25 Integrated Voltage Measurement... 13:50:34 Voltage Offset Correction: v_off_ini = 713.105 uV, v_off_fin = 722.763 uV 13:50:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.480 uVs 13:50:37 I2Y Average and RMS of Measurements VT = -352.584 +- 5.197 uVs I2Y = -32.438 +- 0.478 uTm^2 13:50:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:50:45 Integrated Voltage Measurement... 13:50:54 Voltage Offset Correction: v_off_ini = 706.297 uV, v_off_fin = 704.238 uV 13:50:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -67.805 uVs 13:50:54 Integrated Voltage Measurement... 13:51:03 Voltage Offset Correction: v_off_ini = 703.196 uV, v_off_fin = 714.517 uV 13:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 71.594 uVs 13:51:03 Integrated Voltage Measurement... 13:51:12 Voltage Offset Correction: v_off_ini = 703.756 uV, v_off_fin = 699.643 uV 13:51:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.512 uVs 13:51:12 Integrated Voltage Measurement... 13:51:21 Voltage Offset Correction: v_off_ini = 708.743 uV, v_off_fin = 714.958 uV 13:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.148 uVs 13:51:21 Integrated Voltage Measurement... 13:51:30 Voltage Offset Correction: v_off_ini = 687.220 uV, v_off_fin = 699.073 uV 13:51:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.774 uVs 13:51:30 Integrated Voltage Measurement... 13:51:39 Voltage Offset Correction: v_off_ini = 699.948 uV, v_off_fin = 714.524 uV 13:51:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 87.455 uVs 13:51:44 I1X Average and RMS of Measurements VT = -70.381 +- 3.793 uVs I1X = 14.078 +- 0.758 uTm 13:51:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:51:50 Integrated Voltage Measurement... 13:51:59 Voltage Offset Correction: v_off_ini = 711.765 uV, v_off_fin = 694.336 uV 13:51:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.266 uVs 13:51:59 Integrated Voltage Measurement... 13:52:08 Voltage Offset Correction: v_off_ini = 707.420 uV, v_off_fin = 717.322 uV 13:52:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.495 uVs 13:52:08 Integrated Voltage Measurement... 13:52:17 Voltage Offset Correction: v_off_ini = 707.097 uV, v_off_fin = 696.260 uV 13:52:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.111 uVs 13:52:17 Integrated Voltage Measurement... 13:52:26 Voltage Offset Correction: v_off_ini = 704.786 uV, v_off_fin = 712.603 uV 13:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.682 uVs 13:52:26 Integrated Voltage Measurement... 13:52:35 Voltage Offset Correction: v_off_ini = 714.685 uV, v_off_fin = 694.105 uV 13:52:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.179 uVs 13:52:35 Integrated Voltage Measurement... 13:52:44 Voltage Offset Correction: v_off_ini = 705.848 uV, v_off_fin = 706.258 uV 13:52:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.969 uVs 13:52:49 I1Y Average and RMS of Measurements VT = -211.450 +- 3.881 uVs I1Y = -42.286 +- 0.776 uTm 13:52:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:52:54 Integrated Voltage Measurement... 13:53:03 Voltage Offset Correction: v_off_ini = 684.985 uV, v_off_fin = 690.754 uV 13:53:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.069 uVs 13:53:03 Integrated Voltage Measurement... 13:53:12 Voltage Offset Correction: v_off_ini = 689.561 uV, v_off_fin = 713.755 uV 13:53:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.082 uVs 13:53:12 Integrated Voltage Measurement... 13:53:21 Voltage Offset Correction: v_off_ini = 712.085 uV, v_off_fin = 706.012 uV 13:53:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.543 uVs 13:53:21 Integrated Voltage Measurement... 13:53:30 Voltage Offset Correction: v_off_ini = 723.882 uV, v_off_fin = 715.567 uV 13:53:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.568 uVs 13:53:30 Integrated Voltage Measurement... 13:53:39 Voltage Offset Correction: v_off_ini = 713.445 uV, v_off_fin = 701.721 uV 13:53:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.479 uVs 13:53:39 Integrated Voltage Measurement... 13:53:48 Voltage Offset Correction: v_off_ini = 716.195 uV, v_off_fin = 725.819 uV 13:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.762 uVs 13:53:50 I2X Average and RMS of Measurements VT = -93.417 +- 6.764 uVs I2X = 8.595 +- 0.622 uTm^2 13:53:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:53:56 Integrated Voltage Measurement... 13:54:05 Voltage Offset Correction: v_off_ini = 711.926 uV, v_off_fin = 710.037 uV 13:54:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.278 uVs 13:54:05 Integrated Voltage Measurement... 13:54:14 Voltage Offset Correction: v_off_ini = 718.804 uV, v_off_fin = 717.832 uV 13:54:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.815 uVs 13:54:14 Integrated Voltage Measurement... 13:54:23 Voltage Offset Correction: v_off_ini = 711.403 uV, v_off_fin = 711.098 uV 13:54:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.479 uVs 13:54:23 Integrated Voltage Measurement... 13:54:32 Voltage Offset Correction: v_off_ini = 715.485 uV, v_off_fin = 708.335 uV 13:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.902 uVs 13:54:32 Integrated Voltage Measurement... 13:54:41 Voltage Offset Correction: v_off_ini = 709.444 uV, v_off_fin = 715.894 uV 13:54:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.870 uVs 13:54:41 Integrated Voltage Measurement... 13:54:50 Voltage Offset Correction: v_off_ini = 711.964 uV, v_off_fin = 716.304 uV 13:54:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.601 uVs 13:54:52 I2Y Average and RMS of Measurements VT = -351.158 +- 7.057 uVs I2Y = -32.306 +- 0.649 uTm^2 13:54:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:55:01 Integrated Voltage Measurement... 13:55:10 Voltage Offset Correction: v_off_ini = 703.149 uV, v_off_fin = 697.237 uV 13:55:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -60.459 uVs 13:55:10 Integrated Voltage Measurement... 13:55:19 Voltage Offset Correction: v_off_ini = 705.224 uV, v_off_fin = 703.741 uV 13:55:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.480 uVs 13:55:19 Integrated Voltage Measurement... 13:55:28 Voltage Offset Correction: v_off_ini = 705.843 uV, v_off_fin = 717.215 uV 13:55:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.722 uVs 13:55:28 Integrated Voltage Measurement... 13:55:37 Voltage Offset Correction: v_off_ini = 716.014 uV, v_off_fin = 712.465 uV 13:55:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.776 uVs 13:55:37 Integrated Voltage Measurement... 13:55:46 Voltage Offset Correction: v_off_ini = 702.211 uV, v_off_fin = 699.704 uV 13:55:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.761 uVs 13:55:46 Integrated Voltage Measurement... 13:55:55 Voltage Offset Correction: v_off_ini = 685.966 uV, v_off_fin = 707.492 uV 13:55:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.707 uVs 13:55:59 I1X Average and RMS of Measurements VT = -58.151 +- 9.149 uVs I1X = 11.631 +- 1.829 uTm 13:56:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:56:06 Integrated Voltage Measurement... 13:56:15 Voltage Offset Correction: v_off_ini = 705.835 uV, v_off_fin = 693.227 uV 13:56:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.722 uVs 13:56:15 Integrated Voltage Measurement... 13:56:24 Voltage Offset Correction: v_off_ini = 711.584 uV, v_off_fin = 724.828 uV 13:56:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.519 uVs 13:56:24 Integrated Voltage Measurement... 13:56:33 Voltage Offset Correction: v_off_ini = 711.032 uV, v_off_fin = 696.185 uV 13:56:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.854 uVs 13:56:33 Integrated Voltage Measurement... 13:56:42 Voltage Offset Correction: v_off_ini = 695.465 uV, v_off_fin = 718.052 uV 13:56:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.059 uVs 13:56:42 Integrated Voltage Measurement... 13:56:51 Voltage Offset Correction: v_off_ini = 697.150 uV, v_off_fin = 689.213 uV 13:56:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.035 uVs 13:56:51 Integrated Voltage Measurement... 13:57:00 Voltage Offset Correction: v_off_ini = 701.703 uV, v_off_fin = 723.724 uV 13:57:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.597 uVs 13:57:04 I1Y Average and RMS of Measurements VT = -213.798 +- 5.327 uVs I1Y = -42.760 +- 1.065 uTm 13:57:07 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:57:09 Integrated Voltage Measurement... 13:57:18 Voltage Offset Correction: v_off_ini = 703.454 uV, v_off_fin = 696.834 uV 13:57:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -103.863 uVs 13:57:18 Integrated Voltage Measurement... 13:57:27 Voltage Offset Correction: v_off_ini = 718.010 uV, v_off_fin = 729.666 uV 13:57:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.880 uVs 13:57:27 Integrated Voltage Measurement... 13:57:36 Voltage Offset Correction: v_off_ini = 709.298 uV, v_off_fin = 708.388 uV 13:57:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.118 uVs 13:57:36 Integrated Voltage Measurement... 13:57:45 Voltage Offset Correction: v_off_ini = 718.684 uV, v_off_fin = 724.522 uV 13:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.827 uVs 13:57:45 Integrated Voltage Measurement... 13:57:54 Voltage Offset Correction: v_off_ini = 717.080 uV, v_off_fin = 714.514 uV 13:57:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.108 uVs 13:57:54 Integrated Voltage Measurement... 13:58:03 Voltage Offset Correction: v_off_ini = 723.270 uV, v_off_fin = 731.889 uV 13:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.102 uVs 13:58:06 I2X Average and RMS of Measurements VT = -98.316 +- 2.921 uVs I2X = 9.045 +- 0.269 uTm^2 13:58:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:58:11 Integrated Voltage Measurement... 13:58:20 Voltage Offset Correction: v_off_ini = 714.008 uV, v_off_fin = 716.479 uV 13:58:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.999 uVs 13:58:20 Integrated Voltage Measurement... 13:58:29 Voltage Offset Correction: v_off_ini = 703.583 uV, v_off_fin = 704.842 uV 13:58:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.582 uVs 13:58:29 Integrated Voltage Measurement... 13:58:38 Voltage Offset Correction: v_off_ini = 710.334 uV, v_off_fin = 708.240 uV 13:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.614 uVs 13:58:38 Integrated Voltage Measurement... 13:58:47 Voltage Offset Correction: v_off_ini = 715.379 uV, v_off_fin = 710.317 uV 13:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.764 uVs 13:58:47 Integrated Voltage Measurement... 13:58:56 Voltage Offset Correction: v_off_ini = 706.178 uV, v_off_fin = 709.108 uV 13:58:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.090 uVs 13:58:56 Integrated Voltage Measurement... 13:59:05 Voltage Offset Correction: v_off_ini = 715.428 uV, v_off_fin = 710.944 uV 13:59:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.129 uVs 13:59:08 I2Y Average and RMS of Measurements VT = -350.863 +- 5.191 uVs I2Y = -32.279 +- 0.478 uTm^2 13:59:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:59:29 Integrated Voltage Measurement... 13:59:38 Voltage Offset Correction: v_off_ini = 707.440 uV, v_off_fin = 699.258 uV 13:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.674 uVs 13:59:38 Integrated Voltage Measurement... 13:59:47 Voltage Offset Correction: v_off_ini = 696.104 uV, v_off_fin = 708.922 uV 13:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.749 uVs 13:59:47 Integrated Voltage Measurement... 13:59:56 Voltage Offset Correction: v_off_ini = 706.367 uV, v_off_fin = 713.893 uV 13:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.800 uVs 13:59:56 Integrated Voltage Measurement... 14:00:05 Voltage Offset Correction: v_off_ini = 724.712 uV, v_off_fin = 724.263 uV 14:00:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.121 uVs 14:00:05 Integrated Voltage Measurement... 14:00:14 Voltage Offset Correction: v_off_ini = 702.972 uV, v_off_fin = 709.790 uV 14:00:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.241 uVs 14:00:14 Integrated Voltage Measurement... 14:00:23 Voltage Offset Correction: v_off_ini = 706.687 uV, v_off_fin = 695.999 uV 14:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.941 uVs 14:00:27 I1X Average and RMS of Measurements VT = -57.421 +- 8.571 uVs I1X = 11.484 +- 1.714 uTm 14:00:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:00:34 Integrated Voltage Measurement... 14:00:43 Voltage Offset Correction: v_off_ini = 688.917 uV, v_off_fin = 680.406 uV 14:00:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.012 uVs 14:00:43 Integrated Voltage Measurement... 14:00:52 Voltage Offset Correction: v_off_ini = 697.575 uV, v_off_fin = 696.681 uV 14:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.230 uVs 14:00:52 Integrated Voltage Measurement... 14:01:01 Voltage Offset Correction: v_off_ini = 694.801 uV, v_off_fin = 684.097 uV 14:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.574 uVs 14:01:01 Integrated Voltage Measurement... 14:01:10 Voltage Offset Correction: v_off_ini = 686.967 uV, v_off_fin = 700.653 uV 14:01:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.179 uVs 14:01:10 Integrated Voltage Measurement... 14:01:19 Voltage Offset Correction: v_off_ini = 683.195 uV, v_off_fin = 680.395 uV 14:01:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.886 uVs 14:01:19 Integrated Voltage Measurement... 14:01:28 Voltage Offset Correction: v_off_ini = 683.039 uV, v_off_fin = 689.069 uV 14:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.989 uVs 14:01:32 I1Y Average and RMS of Measurements VT = -228.145 +- 2.966 uVs I1Y = -45.629 +- 0.593 uTm 14:01:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:01:40 Integrated Voltage Measurement... 14:01:49 Voltage Offset Correction: v_off_ini = 666.350 uV, v_off_fin = 682.917 uV 14:01:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.588 uVs 14:01:49 Integrated Voltage Measurement... 14:01:58 Voltage Offset Correction: v_off_ini = 689.097 uV, v_off_fin = 697.397 uV 14:01:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.544 uVs 14:01:58 Integrated Voltage Measurement... 14:02:07 Voltage Offset Correction: v_off_ini = 685.590 uV, v_off_fin = 667.207 uV 14:02:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.473 uVs 14:02:07 Integrated Voltage Measurement... 14:02:16 Voltage Offset Correction: v_off_ini = 695.290 uV, v_off_fin = 703.615 uV 14:02:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.511 uVs 14:02:16 Integrated Voltage Measurement... 14:02:25 Voltage Offset Correction: v_off_ini = 691.391 uV, v_off_fin = 684.629 uV 14:02:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.223 uVs 14:02:25 Integrated Voltage Measurement... 14:02:34 Voltage Offset Correction: v_off_ini = 692.889 uV, v_off_fin = 694.040 uV 14:02:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.626 uVs 14:02:37 I2X Average and RMS of Measurements VT = -85.328 +- 2.224 uVs I2X = 7.850 +- 0.204 uTm^2 14:02:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:02:44 Integrated Voltage Measurement... 14:02:53 Voltage Offset Correction: v_off_ini = 689.238 uV, v_off_fin = 712.653 uV 14:02:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.507 uVs 14:02:53 Integrated Voltage Measurement... 14:03:02 Voltage Offset Correction: v_off_ini = 704.212 uV, v_off_fin = 700.868 uV 14:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.707 uVs 14:03:03 Integrated Voltage Measurement... 14:03:12 Voltage Offset Correction: v_off_ini = 695.652 uV, v_off_fin = 702.137 uV 14:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.309 uVs 14:03:12 Integrated Voltage Measurement... 14:03:21 Voltage Offset Correction: v_off_ini = 695.339 uV, v_off_fin = 693.071 uV 14:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.539 uVs 14:03:21 Integrated Voltage Measurement... 14:03:30 Voltage Offset Correction: v_off_ini = 687.621 uV, v_off_fin = 680.747 uV 14:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.549 uVs 14:03:30 Integrated Voltage Measurement... 14:03:39 Voltage Offset Correction: v_off_ini = 690.491 uV, v_off_fin = 693.567 uV 14:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.350 uVs 14:03:41 I2Y Average and RMS of Measurements VT = -352.160 +- 6.255 uVs I2Y = -32.399 +- 0.575 uTm^2 14:03:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:03:50 Integrated Voltage Measurement... 14:03:59 Voltage Offset Correction: v_off_ini = 709.811 uV, v_off_fin = 701.120 uV 14:03:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.878 uVs 14:03:59 Integrated Voltage Measurement... 14:04:08 Voltage Offset Correction: v_off_ini = 697.301 uV, v_off_fin = 700.398 uV 14:04:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.800 uVs 14:04:08 Integrated Voltage Measurement... 14:04:17 Voltage Offset Correction: v_off_ini = 683.492 uV, v_off_fin = 687.062 uV 14:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.390 uVs 14:04:17 Integrated Voltage Measurement... 14:04:26 Voltage Offset Correction: v_off_ini = 687.779 uV, v_off_fin = 698.481 uV 14:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.537 uVs 14:04:26 Integrated Voltage Measurement... 14:04:35 Voltage Offset Correction: v_off_ini = 696.163 uV, v_off_fin = 687.573 uV 14:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.090 uVs 14:04:35 Integrated Voltage Measurement... 14:04:44 Voltage Offset Correction: v_off_ini = 695.868 uV, v_off_fin = 689.701 uV 14:04:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.438 uVs 14:04:48 I1X Average and RMS of Measurements VT = -59.522 +- 8.559 uVs I1X = 11.904 +- 1.712 uTm 14:04:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:04:55 Integrated Voltage Measurement... 14:05:04 Voltage Offset Correction: v_off_ini = 700.314 uV, v_off_fin = 676.773 uV 14:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.531 uVs 14:05:04 Integrated Voltage Measurement... 14:05:13 Voltage Offset Correction: v_off_ini = 693.074 uV, v_off_fin = 705.330 uV 14:05:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.734 uVs 14:05:13 Integrated Voltage Measurement... 14:05:22 Voltage Offset Correction: v_off_ini = 687.717 uV, v_off_fin = 674.042 uV 14:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.467 uVs 14:05:22 Integrated Voltage Measurement... 14:05:31 Voltage Offset Correction: v_off_ini = 695.987 uV, v_off_fin = 698.824 uV 14:05:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.554 uVs 14:05:31 Integrated Voltage Measurement... 14:05:40 Voltage Offset Correction: v_off_ini = 687.783 uV, v_off_fin = 680.120 uV 14:05:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.864 uVs 14:05:40 Integrated Voltage Measurement... 14:05:49 Voltage Offset Correction: v_off_ini = 687.396 uV, v_off_fin = 698.121 uV 14:05:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.233 uVs 14:05:53 I1Y Average and RMS of Measurements VT = -219.564 +- 1.037 uVs I1Y = -43.913 +- 0.207 uTm 14:05:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:06:01 Integrated Voltage Measurement... 14:06:10 Voltage Offset Correction: v_off_ini = 687.702 uV, v_off_fin = 692.985 uV 14:06:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.044 uVs 14:06:10 Integrated Voltage Measurement... 14:06:19 Voltage Offset Correction: v_off_ini = 702.209 uV, v_off_fin = 710.513 uV 14:06:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.308 uVs 14:06:19 Integrated Voltage Measurement... 14:06:28 Voltage Offset Correction: v_off_ini = 689.996 uV, v_off_fin = 691.457 uV 14:06:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.875 uVs 14:06:28 Integrated Voltage Measurement... 14:06:37 Voltage Offset Correction: v_off_ini = 686.342 uV, v_off_fin = 708.443 uV 14:06:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.662 uVs 14:06:37 Integrated Voltage Measurement... 14:06:46 Voltage Offset Correction: v_off_ini = 700.273 uV, v_off_fin = 691.828 uV 14:06:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.568 uVs 14:06:46 Integrated Voltage Measurement... 14:06:55 Voltage Offset Correction: v_off_ini = 699.090 uV, v_off_fin = 710.180 uV 14:06:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.434 uVs 14:06:58 I2X Average and RMS of Measurements VT = -92.982 +- 7.929 uVs I2X = 8.555 +- 0.730 uTm^2 14:07:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:07:06 Integrated Voltage Measurement... 14:07:15 Voltage Offset Correction: v_off_ini = 689.023 uV, v_off_fin = 689.215 uV 14:07:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.894 uVs 14:07:15 Integrated Voltage Measurement... 14:07:24 Voltage Offset Correction: v_off_ini = 677.309 uV, v_off_fin = 693.043 uV 14:07:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.182 uVs 14:07:24 Integrated Voltage Measurement... 14:07:33 Voltage Offset Correction: v_off_ini = 692.197 uV, v_off_fin = 688.470 uV 14:07:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.248 uVs 14:07:33 Integrated Voltage Measurement... 14:07:42 Voltage Offset Correction: v_off_ini = 693.546 uV, v_off_fin = 701.456 uV 14:07:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.985 uVs 14:07:42 Integrated Voltage Measurement... 14:07:51 Voltage Offset Correction: v_off_ini = 705.068 uV, v_off_fin = 699.961 uV 14:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.826 uVs 14:07:51 Integrated Voltage Measurement... 14:08:00 Voltage Offset Correction: v_off_ini = 700.827 uV, v_off_fin = 695.162 uV 14:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.131 uVs 14:08:02 I2Y Average and RMS of Measurements VT = -345.878 +- 2.953 uVs I2Y = -31.821 +- 0.272 uTm^2 14:08:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:11 Integrated Voltage Measurement... 14:08:20 Voltage Offset Correction: v_off_ini = 691.590 uV, v_off_fin = 690.019 uV 14:08:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.852 uVs 14:08:20 Integrated Voltage Measurement... 14:08:29 Voltage Offset Correction: v_off_ini = 699.251 uV, v_off_fin = 699.507 uV 14:08:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.933 uVs 14:08:29 Integrated Voltage Measurement... 14:08:38 Voltage Offset Correction: v_off_ini = 706.503 uV, v_off_fin = 706.527 uV 14:08:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.478 uVs 14:08:38 Integrated Voltage Measurement... 14:08:47 Voltage Offset Correction: v_off_ini = 709.747 uV, v_off_fin = 703.276 uV 14:08:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.227 uVs 14:08:47 Integrated Voltage Measurement... 14:08:56 Voltage Offset Correction: v_off_ini = 694.827 uV, v_off_fin = 693.237 uV 14:08:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.750 uVs 14:08:56 Integrated Voltage Measurement... 14:09:05 Voltage Offset Correction: v_off_ini = 706.705 uV, v_off_fin = 706.435 uV 14:09:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.078 uVs 14:09:09 I1X Average and RMS of Measurements VT = -58.553 +- 5.143 uVs I1X = 11.711 +- 1.029 uTm 14:09:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:16 Integrated Voltage Measurement... 14:09:25 Voltage Offset Correction: v_off_ini = 714.516 uV, v_off_fin = 705.617 uV 14:09:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.045 uVs 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = 712.149 uV, v_off_fin = 715.087 uV 14:09:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.140 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 699.830 uV, v_off_fin = 701.142 uV 14:09:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.256 uVs 14:09:43 Integrated Voltage Measurement... 14:09:52 Voltage Offset Correction: v_off_ini = 697.369 uV, v_off_fin = 718.665 uV 14:09:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.847 uVs 14:09:52 Integrated Voltage Measurement... 14:10:01 Voltage Offset Correction: v_off_ini = 703.084 uV, v_off_fin = 697.241 uV 14:10:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.476 uVs 14:10:01 Integrated Voltage Measurement... 14:10:10 Voltage Offset Correction: v_off_ini = 703.700 uV, v_off_fin = 717.999 uV 14:10:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.439 uVs 14:10:15 I1Y Average and RMS of Measurements VT = -216.867 +- 4.740 uVs I1Y = -43.373 +- 0.948 uTm 14:10:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:22 Integrated Voltage Measurement... 14:10:31 Voltage Offset Correction: v_off_ini = 694.372 uV, v_off_fin = 694.786 uV 14:10:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.071 uVs 14:10:31 Integrated Voltage Measurement... 14:10:40 Voltage Offset Correction: v_off_ini = 703.056 uV, v_off_fin = 711.144 uV 14:10:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 90.217 uVs 14:10:40 Integrated Voltage Measurement... 14:10:49 Voltage Offset Correction: v_off_ini = 687.584 uV, v_off_fin = 692.385 uV 14:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.224 uVs 14:10:49 Integrated Voltage Measurement... 14:10:58 Voltage Offset Correction: v_off_ini = 694.392 uV, v_off_fin = 701.869 uV 14:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.658 uVs 14:10:58 Integrated Voltage Measurement... 14:11:07 Voltage Offset Correction: v_off_ini = 690.837 uV, v_off_fin = 694.178 uV 14:11:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.642 uVs 14:11:08 Integrated Voltage Measurement... 14:11:17 Voltage Offset Correction: v_off_ini = 682.646 uV, v_off_fin = 699.308 uV 14:11:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.444 uVs 14:11:19 I2X Average and RMS of Measurements VT = -85.209 +- 1.913 uVs I2X = 7.840 +- 0.176 uTm^2 14:11:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:27 Integrated Voltage Measurement... 14:11:36 Voltage Offset Correction: v_off_ini = 682.936 uV, v_off_fin = 686.872 uV 14:11:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.279 uVs 14:11:36 Integrated Voltage Measurement... 14:11:45 Voltage Offset Correction: v_off_ini = 687.245 uV, v_off_fin = 679.920 uV 14:11:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.638 uVs 14:11:45 Integrated Voltage Measurement... 14:11:54 Voltage Offset Correction: v_off_ini = 684.547 uV, v_off_fin = 676.690 uV 14:11:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.794 uVs 14:11:54 Integrated Voltage Measurement... 14:12:03 Voltage Offset Correction: v_off_ini = 673.758 uV, v_off_fin = 671.980 uV 14:12:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.816 uVs 14:12:03 Integrated Voltage Measurement... 14:12:12 Voltage Offset Correction: v_off_ini = 670.601 uV, v_off_fin = 673.046 uV 14:12:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.092 uVs 14:12:12 Integrated Voltage Measurement... 14:12:21 Voltage Offset Correction: v_off_ini = 673.570 uV, v_off_fin = 668.998 uV 14:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.609 uVs 14:12:23 I2Y Average and RMS of Measurements VT = -337.871 +- 2.103 uVs I2Y = -31.084 +- 0.194 uTm^2 14:12:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:12:32 Integrated Voltage Measurement... 14:12:41 Voltage Offset Correction: v_off_ini = 670.388 uV, v_off_fin = 668.068 uV 14:12:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.945 uVs 14:12:41 Integrated Voltage Measurement... 14:12:50 Voltage Offset Correction: v_off_ini = 677.151 uV, v_off_fin = 679.825 uV 14:12:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.008 uVs 14:12:50 Integrated Voltage Measurement... 14:12:59 Voltage Offset Correction: v_off_ini = 683.829 uV, v_off_fin = 670.947 uV 14:12:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.876 uVs 14:12:59 Integrated Voltage Measurement... 14:13:08 Voltage Offset Correction: v_off_ini = 688.140 uV, v_off_fin = 672.057 uV 14:13:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.561 uVs 14:13:08 Integrated Voltage Measurement... 14:13:17 Voltage Offset Correction: v_off_ini = 659.916 uV, v_off_fin = 656.094 uV 14:13:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.487 uVs 14:13:17 Integrated Voltage Measurement... 14:13:26 Voltage Offset Correction: v_off_ini = 652.185 uV, v_off_fin = 663.253 uV 14:13:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.344 uVs 14:13:31 I1X Average and RMS of Measurements VT = -46.870 +- 4.718 uVs I1X = 9.374 +- 0.944 uTm 14:13:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:13:37 Integrated Voltage Measurement... 14:13:46 Voltage Offset Correction: v_off_ini = 657.392 uV, v_off_fin = 647.950 uV 14:13:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.918 uVs 14:13:46 Integrated Voltage Measurement... 14:13:55 Voltage Offset Correction: v_off_ini = 665.721 uV, v_off_fin = 672.105 uV 14:13:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.731 uVs 14:13:56 Integrated Voltage Measurement... 14:14:04 Voltage Offset Correction: v_off_ini = 660.075 uV, v_off_fin = 663.327 uV 14:14:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.027 uVs 14:14:05 Integrated Voltage Measurement... 14:14:13 Voltage Offset Correction: v_off_ini = 662.265 uV, v_off_fin = 673.396 uV 14:14:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.973 uVs 14:14:14 Integrated Voltage Measurement... 14:14:22 Voltage Offset Correction: v_off_ini = 663.830 uV, v_off_fin = 665.756 uV 14:14:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.110 uVs 14:14:23 Integrated Voltage Measurement... 14:14:31 Voltage Offset Correction: v_off_ini = 651.663 uV, v_off_fin = 668.742 uV 14:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 207.332 uVs 14:14:36 I1Y Average and RMS of Measurements VT = -206.515 +- 5.056 uVs I1Y = -41.304 +- 1.011 uTm 14:14:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:14:43 Integrated Voltage Measurement... 14:14:52 Voltage Offset Correction: v_off_ini = 646.949 uV, v_off_fin = 645.726 uV 14:14:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.407 uVs 14:14:52 Integrated Voltage Measurement... 14:15:01 Voltage Offset Correction: v_off_ini = 656.548 uV, v_off_fin = 659.054 uV 14:15:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.342 uVs 14:15:02 Integrated Voltage Measurement... 14:15:11 Voltage Offset Correction: v_off_ini = 660.559 uV, v_off_fin = 652.354 uV 14:15:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.947 uVs 14:15:11 Integrated Voltage Measurement... 14:15:20 Voltage Offset Correction: v_off_ini = 653.144 uV, v_off_fin = 658.982 uV 14:15:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.633 uVs 14:15:20 Integrated Voltage Measurement... 14:15:29 Voltage Offset Correction: v_off_ini = 647.354 uV, v_off_fin = 633.329 uV 14:15:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.523 uVs 14:15:29 Integrated Voltage Measurement... 14:15:38 Voltage Offset Correction: v_off_ini = 655.312 uV, v_off_fin = 655.226 uV 14:15:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.176 uVs 14:15:40 I2X Average and RMS of Measurements VT = -86.171 +- 6.944 uVs I2X = 7.928 +- 0.639 uTm^2 14:15:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:15:48 Integrated Voltage Measurement... 14:15:57 Voltage Offset Correction: v_off_ini = 643.266 uV, v_off_fin = 644.118 uV 14:15:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.924 uVs 14:15:57 Integrated Voltage Measurement... 14:16:06 Voltage Offset Correction: v_off_ini = 634.390 uV, v_off_fin = 645.009 uV 14:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.126 uVs 14:16:06 Integrated Voltage Measurement... 14:16:15 Voltage Offset Correction: v_off_ini = 652.619 uV, v_off_fin = 654.012 uV 14:16:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.168 uVs 14:16:15 Integrated Voltage Measurement... 14:16:24 Voltage Offset Correction: v_off_ini = 652.988 uV, v_off_fin = 652.052 uV 14:16:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.780 uVs 14:16:24 Integrated Voltage Measurement... 14:16:33 Voltage Offset Correction: v_off_ini = 642.813 uV, v_off_fin = 635.567 uV 14:16:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.029 uVs 14:16:33 Integrated Voltage Measurement... 14:16:42 Voltage Offset Correction: v_off_ini = 652.011 uV, v_off_fin = 649.373 uV 14:16:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 327.107 uVs 14:16:44 I2Y Average and RMS of Measurements VT = -334.356 +- 3.624 uVs I2Y = -30.761 +- 0.333 uTm^2 14:16:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:16:53 Integrated Voltage Measurement... 14:17:02 Voltage Offset Correction: v_off_ini = 662.030 uV, v_off_fin = 640.541 uV 14:17:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.637 uVs 14:17:02 Integrated Voltage Measurement... 14:17:11 Voltage Offset Correction: v_off_ini = 636.839 uV, v_off_fin = 639.604 uV 14:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.580 uVs 14:17:11 Integrated Voltage Measurement... 14:17:20 Voltage Offset Correction: v_off_ini = 626.616 uV, v_off_fin = 633.780 uV 14:17:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.158 uVs 14:17:21 Integrated Voltage Measurement... 14:17:29 Voltage Offset Correction: v_off_ini = 637.528 uV, v_off_fin = 641.277 uV 14:17:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.223 uVs 14:17:30 Integrated Voltage Measurement... 14:17:39 Voltage Offset Correction: v_off_ini = 638.722 uV, v_off_fin = 627.689 uV 14:17:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.995 uVs 14:17:39 Integrated Voltage Measurement... 14:17:48 Voltage Offset Correction: v_off_ini = 636.311 uV, v_off_fin = 633.923 uV 14:17:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.656 uVs 14:17:52 I1X Average and RMS of Measurements VT = -58.708 +- 4.351 uVs I1X = 11.742 +- 0.870 uTm 14:17:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:17:59 Integrated Voltage Measurement... 14:18:08 Voltage Offset Correction: v_off_ini = 636.266 uV, v_off_fin = 627.555 uV 14:18:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.119 uVs 14:18:08 Integrated Voltage Measurement... 14:18:17 Voltage Offset Correction: v_off_ini = 635.178 uV, v_off_fin = 642.367 uV 14:18:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.445 uVs 14:18:17 Integrated Voltage Measurement... 14:18:26 Voltage Offset Correction: v_off_ini = 633.385 uV, v_off_fin = 631.813 uV 14:18:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.680 uVs 14:18:26 Integrated Voltage Measurement... 14:18:35 Voltage Offset Correction: v_off_ini = 637.717 uV, v_off_fin = 651.241 uV 14:18:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.752 uVs 14:18:35 Integrated Voltage Measurement... 14:18:44 Voltage Offset Correction: v_off_ini = 638.056 uV, v_off_fin = 620.508 uV 14:18:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.176 uVs 14:18:44 Integrated Voltage Measurement... 14:18:53 Voltage Offset Correction: v_off_ini = 627.226 uV, v_off_fin = 633.702 uV 14:18:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.890 uVs 14:18:57 I1Y Average and RMS of Measurements VT = -207.344 +- 5.587 uVs I1Y = -41.469 +- 1.117 uTm 14:19:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:19:05 Integrated Voltage Measurement... 14:19:14 Voltage Offset Correction: v_off_ini = 622.135 uV, v_off_fin = 623.713 uV 14:19:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.526 uVs 14:19:14 Integrated Voltage Measurement... 14:19:23 Voltage Offset Correction: v_off_ini = 628.169 uV, v_off_fin = 641.714 uV 14:19:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.357 uVs 14:19:23 Integrated Voltage Measurement... 14:19:32 Voltage Offset Correction: v_off_ini = 634.827 uV, v_off_fin = 631.950 uV 14:19:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.245 uVs 14:19:32 Integrated Voltage Measurement... 14:19:41 Voltage Offset Correction: v_off_ini = 658.066 uV, v_off_fin = 652.512 uV 14:19:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.208 uVs 14:19:41 Integrated Voltage Measurement... 14:19:50 Voltage Offset Correction: v_off_ini = 643.023 uV, v_off_fin = 635.000 uV 14:19:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.669 uVs 14:19:50 Integrated Voltage Measurement... 14:19:59 Voltage Offset Correction: v_off_ini = 637.608 uV, v_off_fin = 649.211 uV 14:19:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.699 uVs 14:20:01 I2X Average and RMS of Measurements VT = -69.784 +- 6.022 uVs I2X = 6.420 +- 0.554 uTm^2 14:20:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:20:09 Integrated Voltage Measurement... 14:20:18 Voltage Offset Correction: v_off_ini = 637.750 uV, v_off_fin = 630.286 uV 14:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.254 uVs 14:20:18 Integrated Voltage Measurement... 14:20:27 Voltage Offset Correction: v_off_ini = 629.875 uV, v_off_fin = 623.472 uV 14:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.386 uVs 14:20:27 Integrated Voltage Measurement... 14:20:36 Voltage Offset Correction: v_off_ini = 620.323 uV, v_off_fin = 617.302 uV 14:20:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.869 uVs 14:20:36 Integrated Voltage Measurement... 14:20:45 Voltage Offset Correction: v_off_ini = 625.162 uV, v_off_fin = 631.094 uV 14:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.297 uVs 14:20:45 Integrated Voltage Measurement... 14:20:54 Voltage Offset Correction: v_off_ini = 631.824 uV, v_off_fin = 637.092 uV 14:20:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.710 uVs 14:20:54 Integrated Voltage Measurement... 14:21:03 Voltage Offset Correction: v_off_ini = 634.261 uV, v_off_fin = 637.586 uV 14:21:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.718 uVs 14:21:06 I2Y Average and RMS of Measurements VT = -324.539 +- 3.234 uVs I2Y = -29.858 +- 0.297 uTm^2 14:21:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:21:18 Integrated Voltage Measurement... 14:21:27 Voltage Offset Correction: v_off_ini = 636.275 uV, v_off_fin = 632.164 uV 14:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.742 uVs 14:21:27 Integrated Voltage Measurement... 14:21:36 Voltage Offset Correction: v_off_ini = 635.765 uV, v_off_fin = 629.616 uV 14:21:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.465 uVs 14:21:36 Integrated Voltage Measurement... 14:21:45 Voltage Offset Correction: v_off_ini = 637.466 uV, v_off_fin = 631.789 uV 14:21:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -33.822 uVs 14:21:45 Integrated Voltage Measurement... 14:21:54 Voltage Offset Correction: v_off_ini = 633.567 uV, v_off_fin = 634.089 uV 14:21:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 41.143 uVs 14:21:54 Integrated Voltage Measurement... 14:22:03 Voltage Offset Correction: v_off_ini = 629.060 uV, v_off_fin = 626.167 uV 14:22:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.766 uVs 14:22:03 Integrated Voltage Measurement... 14:22:12 Voltage Offset Correction: v_off_ini = 614.257 uV, v_off_fin = 630.083 uV 14:22:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.219 uVs 14:22:16 I1X Average and RMS of Measurements VT = -49.859 +- 8.794 uVs I1X = 9.972 +- 1.758 uTm 14:22:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:22:23 Integrated Voltage Measurement... 14:22:32 Voltage Offset Correction: v_off_ini = 619.547 uV, v_off_fin = 607.320 uV 14:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.601 uVs 14:22:32 Integrated Voltage Measurement... 14:22:41 Voltage Offset Correction: v_off_ini = 621.514 uV, v_off_fin = 632.567 uV 14:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.974 uVs 14:22:41 Integrated Voltage Measurement... 14:22:50 Voltage Offset Correction: v_off_ini = 621.570 uV, v_off_fin = 612.020 uV 14:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.209 uVs 14:22:50 Integrated Voltage Measurement... 14:22:59 Voltage Offset Correction: v_off_ini = 621.609 uV, v_off_fin = 630.500 uV 14:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.892 uVs 14:22:59 Integrated Voltage Measurement... 14:23:08 Voltage Offset Correction: v_off_ini = 620.056 uV, v_off_fin = 614.792 uV 14:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.902 uVs 14:23:08 Integrated Voltage Measurement... 14:23:17 Voltage Offset Correction: v_off_ini = 614.623 uV, v_off_fin = 643.440 uV 14:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.098 uVs 14:23:21 I1Y Average and RMS of Measurements VT = -221.446 +- 6.132 uVs I1Y = -44.289 +- 1.226 uTm 14:23:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:23:26 Integrated Voltage Measurement... 14:23:35 Voltage Offset Correction: v_off_ini = 622.938 uV, v_off_fin = 610.351 uV 14:23:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -76.407 uVs 14:23:35 Integrated Voltage Measurement... 14:23:44 Voltage Offset Correction: v_off_ini = 621.149 uV, v_off_fin = 625.477 uV 14:23:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.397 uVs 14:23:44 Integrated Voltage Measurement... 14:23:53 Voltage Offset Correction: v_off_ini = 620.257 uV, v_off_fin = 611.506 uV 14:23:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.703 uVs 14:23:53 Integrated Voltage Measurement... 14:24:02 Voltage Offset Correction: v_off_ini = 620.397 uV, v_off_fin = 619.802 uV 14:24:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.497 uVs 14:24:02 Integrated Voltage Measurement... 14:24:11 Voltage Offset Correction: v_off_ini = 610.028 uV, v_off_fin = 598.415 uV 14:24:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.591 uVs 14:24:11 Integrated Voltage Measurement... 14:24:20 Voltage Offset Correction: v_off_ini = 609.474 uV, v_off_fin = 620.266 uV 14:24:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.693 uVs 14:24:23 I2X Average and RMS of Measurements VT = -78.881 +- 4.443 uVs I2X = 7.257 +- 0.409 uTm^2 14:24:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:24:28 Integrated Voltage Measurement... 14:24:37 Voltage Offset Correction: v_off_ini = 613.907 uV, v_off_fin = 615.394 uV 14:24:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.793 uVs 14:24:37 Integrated Voltage Measurement... 14:24:46 Voltage Offset Correction: v_off_ini = 605.291 uV, v_off_fin = 608.222 uV 14:24:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.829 uVs 14:24:46 Integrated Voltage Measurement... 14:24:55 Voltage Offset Correction: v_off_ini = 599.972 uV, v_off_fin = 605.851 uV 14:24:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.783 uVs 14:24:55 Integrated Voltage Measurement... 14:25:04 Voltage Offset Correction: v_off_ini = 610.970 uV, v_off_fin = 604.994 uV 14:25:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.582 uVs 14:25:04 Integrated Voltage Measurement... 14:25:13 Voltage Offset Correction: v_off_ini = 598.669 uV, v_off_fin = 605.468 uV 14:25:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.939 uVs 14:25:13 Integrated Voltage Measurement... 14:25:22 Voltage Offset Correction: v_off_ini = 615.450 uV, v_off_fin = 607.530 uV 14:25:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.339 uVs 14:25:25 I2Y Average and RMS of Measurements VT = -338.544 +- 2.583 uVs I2Y = -31.146 +- 0.238 uTm^2 14:25:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:25:33 Integrated Voltage Measurement... 14:25:42 Voltage Offset Correction: v_off_ini = 605.554 uV, v_off_fin = 605.443 uV 14:25:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.354 uVs 14:25:42 Integrated Voltage Measurement... 14:25:51 Voltage Offset Correction: v_off_ini = 607.088 uV, v_off_fin = 614.607 uV 14:25:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.944 uVs 14:25:51 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = 607.953 uV, v_off_fin = 583.692 uV 14:26:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.111 uVs 14:26:00 Integrated Voltage Measurement... 14:26:09 Voltage Offset Correction: v_off_ini = 591.669 uV, v_off_fin = 596.341 uV 14:26:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 49.927 uVs 14:26:09 Integrated Voltage Measurement... 14:26:18 Voltage Offset Correction: v_off_ini = 602.211 uV, v_off_fin = 596.352 uV 14:26:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.663 uVs 14:26:18 Integrated Voltage Measurement... 14:26:27 Voltage Offset Correction: v_off_ini = 601.643 uV, v_off_fin = 598.266 uV 14:26:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.138 uVs 14:26:31 I1X Average and RMS of Measurements VT = -46.023 +- 6.439 uVs I1X = 9.205 +- 1.288 uTm 14:26:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:26:38 Integrated Voltage Measurement... 14:26:47 Voltage Offset Correction: v_off_ini = 595.527 uV, v_off_fin = 587.222 uV 14:26:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.035 uVs 14:26:47 Integrated Voltage Measurement... 14:26:56 Voltage Offset Correction: v_off_ini = 603.640 uV, v_off_fin = 613.334 uV 14:26:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.940 uVs 14:26:56 Integrated Voltage Measurement... 14:27:05 Voltage Offset Correction: v_off_ini = 606.498 uV, v_off_fin = 599.565 uV 14:27:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.221 uVs 14:27:05 Integrated Voltage Measurement... 14:27:14 Voltage Offset Correction: v_off_ini = 604.798 uV, v_off_fin = 619.141 uV 14:27:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.208 uVs 14:27:14 Integrated Voltage Measurement... 14:27:23 Voltage Offset Correction: v_off_ini = 616.493 uV, v_off_fin = 597.009 uV 14:27:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.938 uVs 14:27:23 Integrated Voltage Measurement... 14:27:32 Voltage Offset Correction: v_off_ini = 614.116 uV, v_off_fin = 612.241 uV 14:27:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.330 uVs 14:27:36 I1Y Average and RMS of Measurements VT = -215.612 +- 0.698 uVs I1Y = -43.122 +- 0.140 uTm 14:27:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:27:42 Integrated Voltage Measurement... 14:27:51 Voltage Offset Correction: v_off_ini = 608.565 uV, v_off_fin = 608.006 uV 14:27:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.928 uVs 14:27:51 Integrated Voltage Measurement... 14:28:00 Voltage Offset Correction: v_off_ini = 612.343 uV, v_off_fin = 612.816 uV 14:28:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.802 uVs 14:28:00 Integrated Voltage Measurement... 14:28:09 Voltage Offset Correction: v_off_ini = 620.613 uV, v_off_fin = 592.610 uV 14:28:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.659 uVs 14:28:09 Integrated Voltage Measurement... 14:28:18 Voltage Offset Correction: v_off_ini = 602.983 uV, v_off_fin = 605.457 uV 14:28:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.799 uVs 14:28:18 Integrated Voltage Measurement... 14:28:27 Voltage Offset Correction: v_off_ini = 609.219 uV, v_off_fin = 590.638 uV 14:28:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.268 uVs 14:28:27 Integrated Voltage Measurement... 14:28:36 Voltage Offset Correction: v_off_ini = 605.532 uV, v_off_fin = 597.377 uV 14:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.935 uVs 14:28:38 I2X Average and RMS of Measurements VT = -77.732 +- 1.868 uVs I2X = 7.152 +- 0.172 uTm^2 14:28:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:28:43 Integrated Voltage Measurement... 14:28:52 Voltage Offset Correction: v_off_ini = 593.503 uV, v_off_fin = 587.965 uV 14:28:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.684 uVs 14:28:52 Integrated Voltage Measurement... 14:29:01 Voltage Offset Correction: v_off_ini = 590.235 uV, v_off_fin = 595.548 uV 14:29:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.906 uVs 14:29:01 Integrated Voltage Measurement... 14:29:10 Voltage Offset Correction: v_off_ini = 591.301 uV, v_off_fin = 604.908 uV 14:29:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.454 uVs 14:29:10 Integrated Voltage Measurement... 14:29:19 Voltage Offset Correction: v_off_ini = 607.244 uV, v_off_fin = 602.603 uV 14:29:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.403 uVs 14:29:19 Integrated Voltage Measurement... 14:29:28 Voltage Offset Correction: v_off_ini = 615.264 uV, v_off_fin = 597.766 uV 14:29:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -354.716 uVs 14:29:28 Integrated Voltage Measurement... 14:29:37 Voltage Offset Correction: v_off_ini = 593.650 uV, v_off_fin = 602.956 uV 14:29:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.702 uVs 14:29:40 I2Y Average and RMS of Measurements VT = -342.311 +- 8.423 uVs I2Y = -31.493 +- 0.775 uTm^2 14:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:48 Integrated Voltage Measurement... 14:29:57 Voltage Offset Correction: v_off_ini = 603.183 uV, v_off_fin = 589.214 uV 14:29:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.804 uVs 14:29:57 Integrated Voltage Measurement... 14:30:06 Voltage Offset Correction: v_off_ini = 604.248 uV, v_off_fin = 599.489 uV 14:30:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.036 uVs 14:30:06 Integrated Voltage Measurement... 14:30:15 Voltage Offset Correction: v_off_ini = 588.723 uV, v_off_fin = 581.447 uV 14:30:15 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -67.848 uVs 14:30:15 Integrated Voltage Measurement... 14:30:24 Voltage Offset Correction: v_off_ini = 591.638 uV, v_off_fin = 584.873 uV 14:30:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 58.367 uVs 14:30:24 Integrated Voltage Measurement... 14:30:33 Voltage Offset Correction: v_off_ini = 570.280 uV, v_off_fin = 573.722 uV 14:30:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.158 uVs 14:30:33 Integrated Voltage Measurement... 14:30:42 Voltage Offset Correction: v_off_ini = 594.585 uV, v_off_fin = 574.621 uV 14:30:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.359 uVs 14:30:46 I1X Average and RMS of Measurements VT = -53.762 +- 10.085 uVs I1X = 10.753 +- 2.018 uTm 14:30:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:53 Integrated Voltage Measurement... 14:31:02 Voltage Offset Correction: v_off_ini = 580.708 uV, v_off_fin = 564.537 uV 14:31:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.623 uVs 14:31:02 Integrated Voltage Measurement... 14:31:11 Voltage Offset Correction: v_off_ini = 575.789 uV, v_off_fin = 583.257 uV 14:31:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.219 uVs 14:31:11 Integrated Voltage Measurement... 14:31:20 Voltage Offset Correction: v_off_ini = 573.728 uV, v_off_fin = 562.613 uV 14:31:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.039 uVs 14:31:20 Integrated Voltage Measurement... 14:31:29 Voltage Offset Correction: v_off_ini = 576.090 uV, v_off_fin = 587.343 uV 14:31:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.331 uVs 14:31:29 Integrated Voltage Measurement... 14:31:38 Voltage Offset Correction: v_off_ini = 582.438 uV, v_off_fin = 561.311 uV 14:31:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.781 uVs 14:31:38 Integrated Voltage Measurement... 14:31:47 Voltage Offset Correction: v_off_ini = 576.193 uV, v_off_fin = 581.300 uV 14:31:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.690 uVs 14:31:51 I1Y Average and RMS of Measurements VT = -219.781 +- 5.187 uVs I1Y = -43.956 +- 1.037 uTm 14:31:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:56 Integrated Voltage Measurement... 14:32:05 Voltage Offset Correction: v_off_ini = 554.904 uV, v_off_fin = 560.829 uV 14:32:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.229 uVs 14:32:05 Integrated Voltage Measurement... 14:32:14 Voltage Offset Correction: v_off_ini = 564.749 uV, v_off_fin = 580.973 uV 14:32:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.191 uVs 14:32:14 Integrated Voltage Measurement... 14:32:23 Voltage Offset Correction: v_off_ini = 572.621 uV, v_off_fin = 567.487 uV 14:32:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.372 uVs 14:32:23 Integrated Voltage Measurement... 14:32:32 Voltage Offset Correction: v_off_ini = 583.633 uV, v_off_fin = 574.476 uV 14:32:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.615 uVs 14:32:32 Integrated Voltage Measurement... 14:32:41 Voltage Offset Correction: v_off_ini = 563.445 uV, v_off_fin = 554.892 uV 14:32:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.765 uVs 14:32:42 Integrated Voltage Measurement... 14:32:51 Voltage Offset Correction: v_off_ini = 548.800 uV, v_off_fin = 557.997 uV 14:32:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 93.480 uVs 14:32:53 I2X Average and RMS of Measurements VT = -83.442 +- 8.070 uVs I2X = 7.677 +- 0.742 uTm^2 14:32:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:58 Integrated Voltage Measurement... 14:33:07 Voltage Offset Correction: v_off_ini = 549.552 uV, v_off_fin = 547.399 uV 14:33:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.121 uVs 14:33:07 Integrated Voltage Measurement... 14:33:16 Voltage Offset Correction: v_off_ini = 551.528 uV, v_off_fin = 555.121 uV 14:33:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.339 uVs 14:33:16 Integrated Voltage Measurement... 14:33:25 Voltage Offset Correction: v_off_ini = 547.374 uV, v_off_fin = 551.848 uV 14:33:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.903 uVs 14:33:25 Integrated Voltage Measurement... 14:33:34 Voltage Offset Correction: v_off_ini = 543.916 uV, v_off_fin = 547.368 uV 14:33:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.648 uVs 14:33:34 Integrated Voltage Measurement... 14:33:43 Voltage Offset Correction: v_off_ini = 546.524 uV, v_off_fin = 542.736 uV 14:33:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.832 uVs 14:33:43 Integrated Voltage Measurement... 14:33:52 Voltage Offset Correction: v_off_ini = 548.732 uV, v_off_fin = 546.445 uV 14:33:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.556 uVs 14:33:55 I2Y Average and RMS of Measurements VT = -332.566 +- 2.486 uVs I2Y = -30.596 +- 0.229 uTm^2 14:33:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:34:03 Integrated Voltage Measurement... 14:34:12 Voltage Offset Correction: v_off_ini = 549.914 uV, v_off_fin = 533.804 uV 14:34:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.693 uVs 14:34:12 Integrated Voltage Measurement... 14:34:21 Voltage Offset Correction: v_off_ini = 538.061 uV, v_off_fin = 535.747 uV 14:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.790 uVs 14:34:21 Integrated Voltage Measurement... 14:34:30 Voltage Offset Correction: v_off_ini = 542.799 uV, v_off_fin = 543.534 uV 14:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.399 uVs 14:34:30 Integrated Voltage Measurement... 14:34:39 Voltage Offset Correction: v_off_ini = 557.074 uV, v_off_fin = 566.505 uV 14:34:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.098 uVs 14:34:39 Integrated Voltage Measurement... 14:34:48 Voltage Offset Correction: v_off_ini = 557.241 uV, v_off_fin = 544.914 uV 14:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.597 uVs 14:34:48 Integrated Voltage Measurement... 14:34:57 Voltage Offset Correction: v_off_ini = 539.844 uV, v_off_fin = 555.370 uV 14:34:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.139 uVs 14:35:01 I1X Average and RMS of Measurements VT = -58.619 +- 7.772 uVs I1X = 11.725 +- 1.555 uTm 14:35:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:35:08 Integrated Voltage Measurement... 14:35:17 Voltage Offset Correction: v_off_ini = 552.712 uV, v_off_fin = 539.305 uV 14:35:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.530 uVs 14:35:17 Integrated Voltage Measurement... 14:35:26 Voltage Offset Correction: v_off_ini = 544.128 uV, v_off_fin = 561.150 uV 14:35:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.618 uVs 14:35:26 Integrated Voltage Measurement... 14:35:35 Voltage Offset Correction: v_off_ini = 540.501 uV, v_off_fin = 543.447 uV 14:35:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.600 uVs 14:35:35 Integrated Voltage Measurement... 14:35:44 Voltage Offset Correction: v_off_ini = 556.967 uV, v_off_fin = 553.161 uV 14:35:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.126 uVs 14:35:44 Integrated Voltage Measurement... 14:35:53 Voltage Offset Correction: v_off_ini = 550.954 uV, v_off_fin = 530.472 uV 14:35:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.089 uVs 14:35:53 Integrated Voltage Measurement... 14:36:02 Voltage Offset Correction: v_off_ini = 542.720 uV, v_off_fin = 557.455 uV 14:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.607 uVs 14:36:06 I1Y Average and RMS of Measurements VT = -215.095 +- 6.052 uVs I1Y = -43.018 +- 1.208 uTm 14:36:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:36:11 Integrated Voltage Measurement... 14:36:20 Voltage Offset Correction: v_off_ini = 539.788 uV, v_off_fin = 537.395 uV 14:36:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.929 uVs 14:36:20 Integrated Voltage Measurement... 14:36:29 Voltage Offset Correction: v_off_ini = 555.454 uV, v_off_fin = 552.452 uV 14:36:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.703 uVs 14:36:29 Integrated Voltage Measurement... 14:36:38 Voltage Offset Correction: v_off_ini = 549.887 uV, v_off_fin = 551.694 uV 14:36:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.067 uVs 14:36:38 Integrated Voltage Measurement... 14:36:47 Voltage Offset Correction: v_off_ini = 549.530 uV, v_off_fin = 561.474 uV 14:36:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.050 uVs 14:36:47 Integrated Voltage Measurement... 14:36:56 Voltage Offset Correction: v_off_ini = 566.952 uV, v_off_fin = 559.134 uV 14:36:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.191 uVs 14:36:56 Integrated Voltage Measurement... 14:37:05 Voltage Offset Correction: v_off_ini = 569.227 uV, v_off_fin = 584.880 uV 14:37:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.857 uVs 14:37:08 I2X Average and RMS of Measurements VT = -81.633 +- 2.439 uVs I2X = 7.510 +- 0.224 uTm^2 14:37:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:37:13 Integrated Voltage Measurement... 14:37:22 Voltage Offset Correction: v_off_ini = 578.189 uV, v_off_fin = 567.672 uV 14:37:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.261 uVs 14:37:22 Integrated Voltage Measurement... 14:37:31 Voltage Offset Correction: v_off_ini = 561.742 uV, v_off_fin = 569.048 uV 14:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.166 uVs 14:37:31 Integrated Voltage Measurement... 14:37:40 Voltage Offset Correction: v_off_ini = 575.677 uV, v_off_fin = 568.783 uV 14:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.241 uVs 14:37:40 Integrated Voltage Measurement... 14:37:49 Voltage Offset Correction: v_off_ini = 579.753 uV, v_off_fin = 573.552 uV 14:37:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 343.057 uVs 14:37:49 Integrated Voltage Measurement... 14:37:58 Voltage Offset Correction: v_off_ini = 562.442 uV, v_off_fin = 567.559 uV 14:37:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.568 uVs 14:37:58 Integrated Voltage Measurement... 14:38:07 Voltage Offset Correction: v_off_ini = 572.828 uV, v_off_fin = 584.541 uV 14:38:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.607 uVs 14:38:09 I2Y Average and RMS of Measurements VT = -342.150 +- 3.437 uVs I2Y = -31.478 +- 0.316 uTm^2 14:38:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:38:17 Integrated Voltage Measurement... 14:38:26 Voltage Offset Correction: v_off_ini = 585.206 uV, v_off_fin = 578.344 uV 14:38:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.034 uVs 14:38:26 Integrated Voltage Measurement... 14:38:35 Voltage Offset Correction: v_off_ini = 600.181 uV, v_off_fin = 599.331 uV 14:38:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.705 uVs 14:38:35 Integrated Voltage Measurement... 14:38:44 Voltage Offset Correction: v_off_ini = 601.131 uV, v_off_fin = 587.531 uV 14:38:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.197 uVs 14:38:44 Integrated Voltage Measurement... 14:38:53 Voltage Offset Correction: v_off_ini = 589.811 uV, v_off_fin = 586.244 uV 14:38:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.716 uVs 14:38:53 Integrated Voltage Measurement... 14:39:02 Voltage Offset Correction: v_off_ini = 587.580 uV, v_off_fin = 575.458 uV 14:39:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.138 uVs 14:39:02 Integrated Voltage Measurement... 14:39:11 Voltage Offset Correction: v_off_ini = 600.218 uV, v_off_fin = 593.047 uV 14:39:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.774 uVs 14:39:16 I1X Average and RMS of Measurements VT = -49.261 +- 9.939 uVs I1X = 9.852 +- 1.988 uTm 14:39:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:39:22 Integrated Voltage Measurement... 14:39:31 Voltage Offset Correction: v_off_ini = 580.893 uV, v_off_fin = 561.233 uV 14:39:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.132 uVs 14:39:31 Integrated Voltage Measurement... 14:39:40 Voltage Offset Correction: v_off_ini = 578.557 uV, v_off_fin = 589.342 uV 14:39:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.189 uVs 14:39:40 Integrated Voltage Measurement... 14:39:49 Voltage Offset Correction: v_off_ini = 574.210 uV, v_off_fin = 561.906 uV 14:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.939 uVs 14:39:49 Integrated Voltage Measurement... 14:39:58 Voltage Offset Correction: v_off_ini = 584.913 uV, v_off_fin = 595.776 uV 14:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.469 uVs 14:39:58 Integrated Voltage Measurement... 14:40:07 Voltage Offset Correction: v_off_ini = 570.241 uV, v_off_fin = 557.279 uV 14:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.901 uVs 14:40:07 Integrated Voltage Measurement... 14:40:16 Voltage Offset Correction: v_off_ini = 586.523 uV, v_off_fin = 579.547 uV 14:40:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 205.399 uVs 14:40:21 I1Y Average and RMS of Measurements VT = -214.338 +- 9.563 uVs I1Y = -42.865 +- 1.912 uTm 14:40:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:40:26 Integrated Voltage Measurement... 14:40:35 Voltage Offset Correction: v_off_ini = 566.209 uV, v_off_fin = 567.178 uV 14:40:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -86.339 uVs 14:40:35 Integrated Voltage Measurement... 14:40:44 Voltage Offset Correction: v_off_ini = 576.911 uV, v_off_fin = 574.503 uV 14:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.316 uVs 14:40:44 Integrated Voltage Measurement... 14:40:53 Voltage Offset Correction: v_off_ini = 578.227 uV, v_off_fin = 564.285 uV 14:40:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.871 uVs 14:40:53 Integrated Voltage Measurement... 14:41:02 Voltage Offset Correction: v_off_ini = 567.997 uV, v_off_fin = 583.220 uV 14:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.263 uVs 14:41:02 Integrated Voltage Measurement... 14:41:11 Voltage Offset Correction: v_off_ini = 558.519 uV, v_off_fin = 555.492 uV 14:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.360 uVs 14:41:11 Integrated Voltage Measurement... 14:41:20 Voltage Offset Correction: v_off_ini = 580.646 uV, v_off_fin = 577.513 uV 14:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.931 uVs 14:41:22 I2X Average and RMS of Measurements VT = -81.513 +- 8.403 uVs I2X = 7.499 +- 0.773 uTm^2 14:41:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:41:27 Integrated Voltage Measurement... 14:41:36 Voltage Offset Correction: v_off_ini = 558.050 uV, v_off_fin = 564.028 uV 14:41:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.197 uVs 14:41:37 Integrated Voltage Measurement... 14:41:46 Voltage Offset Correction: v_off_ini = 558.636 uV, v_off_fin = 558.718 uV 14:41:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 355.562 uVs 14:41:46 Integrated Voltage Measurement... 14:41:55 Voltage Offset Correction: v_off_ini = 572.457 uV, v_off_fin = 565.967 uV 14:41:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.285 uVs 14:41:55 Integrated Voltage Measurement... 14:42:04 Voltage Offset Correction: v_off_ini = 562.728 uV, v_off_fin = 568.756 uV 14:42:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.589 uVs 14:42:04 Integrated Voltage Measurement... 14:42:13 Voltage Offset Correction: v_off_ini = 564.896 uV, v_off_fin = 563.302 uV 14:42:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.094 uVs 14:42:13 Integrated Voltage Measurement... 14:42:22 Voltage Offset Correction: v_off_ini = 566.027 uV, v_off_fin = 580.134 uV 14:42:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.820 uVs 14:42:24 I2Y Average and RMS of Measurements VT = -336.758 +- 1.343 uVs I2Y = -30.982 +- 0.123 uTm^2 14:42:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:42:45 Integrated Voltage Measurement... 14:42:54 Voltage Offset Correction: v_off_ini = 564.834 uV, v_off_fin = 540.136 uV 14:42:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.095 uVs 14:42:54 Integrated Voltage Measurement... 14:43:03 Voltage Offset Correction: v_off_ini = 539.039 uV, v_off_fin = 559.288 uV 14:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.739 uVs 14:43:03 Integrated Voltage Measurement... 14:43:12 Voltage Offset Correction: v_off_ini = 541.861 uV, v_off_fin = 557.203 uV 14:43:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.724 uVs 14:43:12 Integrated Voltage Measurement... 14:43:21 Voltage Offset Correction: v_off_ini = 533.815 uV, v_off_fin = 550.939 uV 14:43:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.053 uVs 14:43:22 Integrated Voltage Measurement... 14:43:30 Voltage Offset Correction: v_off_ini = 548.385 uV, v_off_fin = 548.870 uV 14:43:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.554 uVs 14:43:31 Integrated Voltage Measurement... 14:43:39 Voltage Offset Correction: v_off_ini = 551.812 uV, v_off_fin = 547.905 uV 14:43:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.447 uVs 14:43:44 I1X Average and RMS of Measurements VT = -47.102 +- 4.869 uVs I1X = 9.420 +- 0.974 uTm 14:43:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:43:51 Integrated Voltage Measurement... 14:43:59 Voltage Offset Correction: v_off_ini = 543.376 uV, v_off_fin = 513.285 uV 14:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.405 uVs 14:44:00 Integrated Voltage Measurement... 14:44:08 Voltage Offset Correction: v_off_ini = 542.585 uV, v_off_fin = 543.578 uV 14:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.704 uVs 14:44:09 Integrated Voltage Measurement... 14:44:17 Voltage Offset Correction: v_off_ini = 536.582 uV, v_off_fin = 532.014 uV 14:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.929 uVs 14:44:18 Integrated Voltage Measurement... 14:44:26 Voltage Offset Correction: v_off_ini = 527.409 uV, v_off_fin = 546.555 uV 14:44:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.422 uVs 14:44:27 Integrated Voltage Measurement... 14:44:35 Voltage Offset Correction: v_off_ini = 512.050 uV, v_off_fin = 505.561 uV 14:44:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.150 uVs 14:44:35 Integrated Voltage Measurement... 14:44:44 Voltage Offset Correction: v_off_ini = 530.348 uV, v_off_fin = 535.994 uV 14:44:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.169 uVs 14:44:49 I1Y Average and RMS of Measurements VT = -231.630 +- 4.316 uVs I1Y = -46.326 +- 0.863 uTm 14:44:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:44:56 Integrated Voltage Measurement... 14:45:05 Voltage Offset Correction: v_off_ini = 522.457 uV, v_off_fin = 522.286 uV 14:45:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.654 uVs 14:45:05 Integrated Voltage Measurement... 14:45:14 Voltage Offset Correction: v_off_ini = 529.075 uV, v_off_fin = 533.836 uV 14:45:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.343 uVs 14:45:14 Integrated Voltage Measurement... 14:45:23 Voltage Offset Correction: v_off_ini = 518.928 uV, v_off_fin = 518.070 uV 14:45:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.632 uVs 14:45:23 Integrated Voltage Measurement... 14:45:32 Voltage Offset Correction: v_off_ini = 526.339 uV, v_off_fin = 539.688 uV 14:45:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.757 uVs 14:45:32 Integrated Voltage Measurement... 14:45:41 Voltage Offset Correction: v_off_ini = 534.850 uV, v_off_fin = 524.509 uV 14:45:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.686 uVs 14:45:41 Integrated Voltage Measurement... 14:45:50 Voltage Offset Correction: v_off_ini = 531.885 uV, v_off_fin = 530.124 uV 14:45:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.794 uVs 14:45:53 I2X Average and RMS of Measurements VT = -76.311 +- 2.326 uVs I2X = 7.021 +- 0.214 uTm^2 14:45:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:46:01 Integrated Voltage Measurement... 14:46:10 Voltage Offset Correction: v_off_ini = 527.150 uV, v_off_fin = 519.612 uV 14:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.306 uVs 14:46:10 Integrated Voltage Measurement... 14:46:19 Voltage Offset Correction: v_off_ini = 539.300 uV, v_off_fin = 533.693 uV 14:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.628 uVs 14:46:19 Integrated Voltage Measurement... 14:46:28 Voltage Offset Correction: v_off_ini = 542.476 uV, v_off_fin = 554.840 uV 14:46:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.781 uVs 14:46:28 Integrated Voltage Measurement... 14:46:37 Voltage Offset Correction: v_off_ini = 540.617 uV, v_off_fin = 532.576 uV 14:46:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.730 uVs 14:46:37 Integrated Voltage Measurement... 14:46:46 Voltage Offset Correction: v_off_ini = 529.102 uV, v_off_fin = 527.563 uV 14:46:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.664 uVs 14:46:46 Integrated Voltage Measurement... 14:46:55 Voltage Offset Correction: v_off_ini = 523.386 uV, v_off_fin = 527.980 uV 14:46:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.458 uVs 14:46:57 I2Y Average and RMS of Measurements VT = -333.428 +- 0.974 uVs I2Y = -30.675 +- 0.090 uTm^2 14:47:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:47:06 Integrated Voltage Measurement... 14:47:15 Voltage Offset Correction: v_off_ini = 534.497 uV, v_off_fin = 502.450 uV 14:47:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -59.312 uVs 14:47:15 Integrated Voltage Measurement... 14:47:24 Voltage Offset Correction: v_off_ini = 508.952 uV, v_off_fin = 519.785 uV 14:47:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.470 uVs 14:47:24 Integrated Voltage Measurement... 14:47:33 Voltage Offset Correction: v_off_ini = 500.674 uV, v_off_fin = 501.526 uV 14:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -50.345 uVs 14:47:33 Integrated Voltage Measurement... 14:47:42 Voltage Offset Correction: v_off_ini = 504.808 uV, v_off_fin = 507.437 uV 14:47:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.816 uVs 14:47:42 Integrated Voltage Measurement... 14:47:51 Voltage Offset Correction: v_off_ini = 496.788 uV, v_off_fin = 506.127 uV 14:47:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.447 uVs 14:47:51 Integrated Voltage Measurement... 14:48:00 Voltage Offset Correction: v_off_ini = 511.973 uV, v_off_fin = 507.267 uV 14:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.904 uVs 14:48:04 I1X Average and RMS of Measurements VT = -52.049 +- 1.011 uVs I1X = 10.410 +- 0.203 uTm 14:48:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:48:11 Integrated Voltage Measurement... 14:48:20 Voltage Offset Correction: v_off_ini = 524.152 uV, v_off_fin = 509.915 uV 14:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.732 uVs 14:48:20 Integrated Voltage Measurement... 14:48:29 Voltage Offset Correction: v_off_ini = 505.861 uV, v_off_fin = 524.688 uV 14:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.543 uVs 14:48:29 Integrated Voltage Measurement... 14:48:38 Voltage Offset Correction: v_off_ini = 514.343 uV, v_off_fin = 510.039 uV 14:48:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.237 uVs 14:48:38 Integrated Voltage Measurement... 14:48:47 Voltage Offset Correction: v_off_ini = 514.725 uV, v_off_fin = 525.874 uV 14:48:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.139 uVs 14:48:47 Integrated Voltage Measurement... 14:48:56 Voltage Offset Correction: v_off_ini = 514.266 uV, v_off_fin = 503.438 uV 14:48:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.529 uVs 14:48:56 Integrated Voltage Measurement... 14:49:05 Voltage Offset Correction: v_off_ini = 527.273 uV, v_off_fin = 536.153 uV 14:49:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.269 uVs 14:49:09 I1Y Average and RMS of Measurements VT = -218.408 +- 3.604 uVs I1Y = -43.682 +- 0.721 uTm 14:49:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:49:17 Integrated Voltage Measurement... 14:49:26 Voltage Offset Correction: v_off_ini = 510.247 uV, v_off_fin = 508.326 uV 14:49:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.138 uVs 14:49:26 Integrated Voltage Measurement... 14:49:35 Voltage Offset Correction: v_off_ini = 524.536 uV, v_off_fin = 521.659 uV 14:49:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.324 uVs 14:49:35 Integrated Voltage Measurement... 14:49:44 Voltage Offset Correction: v_off_ini = 516.487 uV, v_off_fin = 506.977 uV 14:49:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.331 uVs 14:49:44 Integrated Voltage Measurement... 14:49:53 Voltage Offset Correction: v_off_ini = 515.619 uV, v_off_fin = 520.794 uV 14:49:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.533 uVs 14:49:53 Integrated Voltage Measurement... 14:50:02 Voltage Offset Correction: v_off_ini = 511.814 uV, v_off_fin = 508.599 uV 14:50:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.710 uVs 14:50:02 Integrated Voltage Measurement... 14:50:11 Voltage Offset Correction: v_off_ini = 519.676 uV, v_off_fin = 532.851 uV 14:50:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.645 uVs 14:50:13 I2X Average and RMS of Measurements VT = -72.780 +- 6.636 uVs I2X = 6.696 +- 0.611 uTm^2 14:50:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:50:21 Integrated Voltage Measurement... 14:50:30 Voltage Offset Correction: v_off_ini = 527.730 uV, v_off_fin = 517.596 uV 14:50:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.309 uVs 14:50:30 Integrated Voltage Measurement... 14:50:39 Voltage Offset Correction: v_off_ini = 519.052 uV, v_off_fin = 520.159 uV 14:50:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.844 uVs 14:50:39 Integrated Voltage Measurement... 14:50:48 Voltage Offset Correction: v_off_ini = 524.407 uV, v_off_fin = 514.225 uV 14:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.384 uVs 14:50:48 Integrated Voltage Measurement... 14:50:57 Voltage Offset Correction: v_off_ini = 532.538 uV, v_off_fin = 517.868 uV 14:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.237 uVs 14:50:57 Integrated Voltage Measurement... 14:51:06 Voltage Offset Correction: v_off_ini = 515.433 uV, v_off_fin = 515.768 uV 14:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.588 uVs 14:51:06 Integrated Voltage Measurement... 14:51:15 Voltage Offset Correction: v_off_ini = 523.613 uV, v_off_fin = 521.793 uV 14:51:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.624 uVs 14:51:17 I2Y Average and RMS of Measurements VT = -324.831 +- 3.985 uVs I2Y = -29.884 +- 0.367 uTm^2 14:51:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:26 Integrated Voltage Measurement... 14:51:35 Voltage Offset Correction: v_off_ini = 533.935 uV, v_off_fin = 519.559 uV 14:51:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.168 uVs 14:51:35 Integrated Voltage Measurement... 14:51:44 Voltage Offset Correction: v_off_ini = 519.065 uV, v_off_fin = 517.228 uV 14:51:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.139 uVs 14:51:44 Integrated Voltage Measurement... 14:51:53 Voltage Offset Correction: v_off_ini = 520.973 uV, v_off_fin = 519.127 uV 14:51:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.897 uVs 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 510.099 uV, v_off_fin = 517.862 uV 14:52:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.224 uVs 14:52:02 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 513.125 uV, v_off_fin = 513.275 uV 14:52:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.669 uVs 14:52:11 Integrated Voltage Measurement... 14:52:20 Voltage Offset Correction: v_off_ini = 514.461 uV, v_off_fin = 527.528 uV 14:52:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.730 uVs 14:52:25 I1X Average and RMS of Measurements VT = -52.971 +- 3.748 uVs I1X = 10.594 +- 0.750 uTm 14:52:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:31 Integrated Voltage Measurement... 14:52:40 Voltage Offset Correction: v_off_ini = 513.430 uV, v_off_fin = 504.204 uV 14:52:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.596 uVs 14:52:40 Integrated Voltage Measurement... 14:52:49 Voltage Offset Correction: v_off_ini = 526.587 uV, v_off_fin = 531.746 uV 14:52:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.767 uVs 14:52:49 Integrated Voltage Measurement... 14:52:58 Voltage Offset Correction: v_off_ini = 532.912 uV, v_off_fin = 497.873 uV 14:52:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.172 uVs 14:52:58 Integrated Voltage Measurement... 14:53:07 Voltage Offset Correction: v_off_ini = 522.005 uV, v_off_fin = 526.040 uV 14:53:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.620 uVs 14:53:07 Integrated Voltage Measurement... 14:53:16 Voltage Offset Correction: v_off_ini = 519.297 uV, v_off_fin = 511.089 uV 14:53:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.781 uVs 14:53:16 Integrated Voltage Measurement... 14:53:25 Voltage Offset Correction: v_off_ini = 523.263 uV, v_off_fin = 527.599 uV 14:53:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.473 uVs 14:53:29 I1Y Average and RMS of Measurements VT = -214.568 +- 6.575 uVs I1Y = -42.914 +- 1.315 uTm 14:53:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:37 Integrated Voltage Measurement... 14:53:46 Voltage Offset Correction: v_off_ini = 519.975 uV, v_off_fin = 515.620 uV 14:53:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.914 uVs 14:53:46 Integrated Voltage Measurement... 14:53:55 Voltage Offset Correction: v_off_ini = 517.559 uV, v_off_fin = 531.402 uV 14:53:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.633 uVs 14:53:55 Integrated Voltage Measurement... 14:54:04 Voltage Offset Correction: v_off_ini = 513.450 uV, v_off_fin = 504.514 uV 14:54:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.146 uVs 14:54:04 Integrated Voltage Measurement... 14:54:13 Voltage Offset Correction: v_off_ini = 523.797 uV, v_off_fin = 533.659 uV 14:54:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.370 uVs 14:54:13 Integrated Voltage Measurement... 14:54:22 Voltage Offset Correction: v_off_ini = 509.141 uV, v_off_fin = 506.973 uV 14:54:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.884 uVs 14:54:22 Integrated Voltage Measurement... 14:54:31 Voltage Offset Correction: v_off_ini = 522.736 uV, v_off_fin = 524.217 uV 14:54:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.641 uVs 14:54:34 I2X Average and RMS of Measurements VT = -77.098 +- 0.237 uVs I2X = 7.093 +- 0.021 uTm^2 14:54:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:41 Integrated Voltage Measurement... 14:54:50 Voltage Offset Correction: v_off_ini = 511.333 uV, v_off_fin = 503.554 uV 14:54:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.140 uVs 14:54:50 Integrated Voltage Measurement... 14:54:59 Voltage Offset Correction: v_off_ini = 510.488 uV, v_off_fin = 518.917 uV 14:54:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.207 uVs 14:54:59 Integrated Voltage Measurement... 14:55:08 Voltage Offset Correction: v_off_ini = 513.262 uV, v_off_fin = 510.342 uV 14:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.242 uVs 14:55:08 Integrated Voltage Measurement... 14:55:17 Voltage Offset Correction: v_off_ini = 519.986 uV, v_off_fin = 516.922 uV 14:55:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.838 uVs 14:55:18 Integrated Voltage Measurement... 14:55:26 Voltage Offset Correction: v_off_ini = 524.917 uV, v_off_fin = 527.544 uV 14:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.526 uVs 14:55:27 Integrated Voltage Measurement... 14:55:36 Voltage Offset Correction: v_off_ini = 517.547 uV, v_off_fin = 515.082 uV 14:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.527 uVs 14:55:38 I2Y Average and RMS of Measurements VT = -322.080 +- 5.253 uVs I2Y = -29.631 +- 0.483 uTm^2 14:55:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:55:47 Integrated Voltage Measurement... 14:55:56 Voltage Offset Correction: v_off_ini = 519.295 uV, v_off_fin = 498.448 uV 14:55:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.672 uVs 14:55:56 Integrated Voltage Measurement... 14:56:05 Voltage Offset Correction: v_off_ini = 522.105 uV, v_off_fin = 531.270 uV 14:56:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.661 uVs 14:56:05 Integrated Voltage Measurement... 14:56:14 Voltage Offset Correction: v_off_ini = 524.095 uV, v_off_fin = 520.057 uV 14:56:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.544 uVs 14:56:14 Integrated Voltage Measurement... 14:56:23 Voltage Offset Correction: v_off_ini = 534.574 uV, v_off_fin = 524.349 uV 14:56:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.109 uVs 14:56:23 Integrated Voltage Measurement... 14:56:32 Voltage Offset Correction: v_off_ini = 514.608 uV, v_off_fin = 531.577 uV 14:56:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.944 uVs 14:56:32 Integrated Voltage Measurement... 14:56:41 Voltage Offset Correction: v_off_ini = 530.638 uV, v_off_fin = 534.253 uV 14:56:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.112 uVs 14:56:45 I1X Average and RMS of Measurements VT = -45.674 +- 10.946 uVs I1X = 9.135 +- 2.189 uTm 14:56:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:56:52 Integrated Voltage Measurement... 14:57:01 Voltage Offset Correction: v_off_ini = 520.688 uV, v_off_fin = 511.027 uV 14:57:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.840 uVs 14:57:01 Integrated Voltage Measurement... 14:57:10 Voltage Offset Correction: v_off_ini = 520.579 uV, v_off_fin = 525.540 uV 14:57:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.954 uVs 14:57:10 Integrated Voltage Measurement... 14:57:19 Voltage Offset Correction: v_off_ini = 518.615 uV, v_off_fin = 503.439 uV 14:57:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.933 uVs 14:57:19 Integrated Voltage Measurement... 14:57:28 Voltage Offset Correction: v_off_ini = 517.684 uV, v_off_fin = 522.605 uV 14:57:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.853 uVs 14:57:28 Integrated Voltage Measurement... 14:57:37 Voltage Offset Correction: v_off_ini = 516.613 uV, v_off_fin = 497.823 uV 14:57:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.896 uVs 14:57:37 Integrated Voltage Measurement... 14:57:46 Voltage Offset Correction: v_off_ini = 503.248 uV, v_off_fin = 518.151 uV 14:57:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.816 uVs 14:57:50 I1Y Average and RMS of Measurements VT = -208.882 +- 1.226 uVs I1Y = -41.776 +- 0.245 uTm 14:57:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:57:58 Integrated Voltage Measurement... 14:58:07 Voltage Offset Correction: v_off_ini = 495.275 uV, v_off_fin = 510.000 uV 14:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.194 uVs 14:58:07 Integrated Voltage Measurement... 14:58:16 Voltage Offset Correction: v_off_ini = 504.729 uV, v_off_fin = 518.079 uV 14:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.595 uVs 14:58:16 Integrated Voltage Measurement... 14:58:25 Voltage Offset Correction: v_off_ini = 506.397 uV, v_off_fin = 502.004 uV 14:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.575 uVs 14:58:25 Integrated Voltage Measurement... 14:58:34 Voltage Offset Correction: v_off_ini = 506.373 uV, v_off_fin = 513.401 uV 14:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.696 uVs 14:58:34 Integrated Voltage Measurement... 14:58:43 Voltage Offset Correction: v_off_ini = 515.765 uV, v_off_fin = 486.422 uV 14:58:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.131 uVs 14:58:43 Integrated Voltage Measurement... 14:58:52 Voltage Offset Correction: v_off_ini = 512.603 uV, v_off_fin = 531.027 uV 14:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.545 uVs 14:58:54 I2X Average and RMS of Measurements VT = -81.623 +- 7.858 uVs I2X = 7.509 +- 0.723 uTm^2 14:58:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 516.305 uV, v_off_fin = 499.291 uV 14:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.251 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 512.989 uV, v_off_fin = 515.590 uV 14:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.523 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 524.375 uV, v_off_fin = 518.120 uV 14:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.900 uVs 14:59:29 Integrated Voltage Measurement... 14:59:38 Voltage Offset Correction: v_off_ini = 524.778 uV, v_off_fin = 526.313 uV 14:59:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.180 uVs 14:59:38 Integrated Voltage Measurement... 14:59:47 Voltage Offset Correction: v_off_ini = 519.105 uV, v_off_fin = 524.486 uV 14:59:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.110 uVs 14:59:47 Integrated Voltage Measurement... 14:59:56 Voltage Offset Correction: v_off_ini = 511.965 uV, v_off_fin = 511.518 uV 14:59:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 327.712 uVs 14:59:58 I2Y Average and RMS of Measurements VT = -319.446 +- 3.639 uVs I2Y = -29.390 +- 0.334 uTm^2 15:00:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 515.603 uV, v_off_fin = 501.257 uV 15:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.119 uVs 15:00:16 Integrated Voltage Measurement... 15:00:25 Voltage Offset Correction: v_off_ini = 509.315 uV, v_off_fin = 504.596 uV 15:00:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.351 uVs 15:00:25 Integrated Voltage Measurement... 15:00:34 Voltage Offset Correction: v_off_ini = 497.321 uV, v_off_fin = 502.249 uV 15:00:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.990 uVs 15:00:34 Integrated Voltage Measurement... 15:00:43 Voltage Offset Correction: v_off_ini = 494.522 uV, v_off_fin = 510.748 uV 15:00:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.022 uVs 15:00:43 Integrated Voltage Measurement... 15:00:52 Voltage Offset Correction: v_off_ini = 499.234 uV, v_off_fin = 501.958 uV 15:00:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.320 uVs 15:00:52 Integrated Voltage Measurement... 15:01:01 Voltage Offset Correction: v_off_ini = 507.282 uV, v_off_fin = 498.259 uV 15:01:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.982 uVs 15:01:05 I1X Average and RMS of Measurements VT = -44.297 +- 4.572 uVs I1X = 8.860 +- 0.914 uTm 15:01:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:01:12 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 495.240 uV, v_off_fin = 469.725 uV 15:01:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.995 uVs 15:01:21 Integrated Voltage Measurement... 15:01:30 Voltage Offset Correction: v_off_ini = 478.881 uV, v_off_fin = 493.993 uV 15:01:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.329 uVs 15:01:30 Integrated Voltage Measurement... 15:01:39 Voltage Offset Correction: v_off_ini = 439.799 uV, v_off_fin = 469.749 uV 15:01:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.157 uVs 15:01:39 Integrated Voltage Measurement... 15:01:48 Voltage Offset Correction: v_off_ini = 490.513 uV, v_off_fin = 504.429 uV 15:01:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.799 uVs 15:01:48 Integrated Voltage Measurement... 15:01:57 Voltage Offset Correction: v_off_ini = 530.045 uV, v_off_fin = 487.548 uV 15:01:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.396 uVs 15:01:57 Integrated Voltage Measurement... 15:02:06 Voltage Offset Correction: v_off_ini = 487.749 uV, v_off_fin = 508.792 uV 15:02:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.340 uVs 15:02:10 I1Y Average and RMS of Measurements VT = -202.169 +- 17.091 uVs I1Y = -40.434 +- 3.418 uTm 15:02:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:02:18 Integrated Voltage Measurement... 15:02:27 Voltage Offset Correction: v_off_ini = 484.908 uV, v_off_fin = 477.764 uV 15:02:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.019 uVs 15:02:27 Integrated Voltage Measurement... 15:02:36 Voltage Offset Correction: v_off_ini = 485.230 uV, v_off_fin = 495.020 uV 15:02:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.720 uVs 15:02:36 Integrated Voltage Measurement... 15:02:45 Voltage Offset Correction: v_off_ini = 485.735 uV, v_off_fin = 470.029 uV 15:02:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.202 uVs 15:02:45 Integrated Voltage Measurement... 15:02:54 Voltage Offset Correction: v_off_ini = 478.375 uV, v_off_fin = 471.209 uV 15:02:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.502 uVs 15:02:54 Integrated Voltage Measurement... 15:03:03 Voltage Offset Correction: v_off_ini = 453.224 uV, v_off_fin = 444.891 uV 15:03:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.664 uVs 15:03:03 Integrated Voltage Measurement... 15:03:12 Voltage Offset Correction: v_off_ini = 452.444 uV, v_off_fin = 467.620 uV 15:03:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.298 uVs 15:03:15 I2X Average and RMS of Measurements VT = -66.568 +- 1.488 uVs I2X = 6.125 +- 0.137 uTm^2 15:03:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:03:22 Integrated Voltage Measurement... 15:03:31 Voltage Offset Correction: v_off_ini = 465.660 uV, v_off_fin = 445.734 uV 15:03:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.111 uVs 15:03:31 Integrated Voltage Measurement... 15:03:40 Voltage Offset Correction: v_off_ini = 447.775 uV, v_off_fin = 475.577 uV 15:03:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.502 uVs 15:03:40 Integrated Voltage Measurement... 15:03:49 Voltage Offset Correction: v_off_ini = 478.185 uV, v_off_fin = 488.497 uV 15:03:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.918 uVs 15:03:50 Integrated Voltage Measurement... 15:03:58 Voltage Offset Correction: v_off_ini = 481.361 uV, v_off_fin = 467.625 uV 15:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.477 uVs 15:03:59 Integrated Voltage Measurement... 15:04:08 Voltage Offset Correction: v_off_ini = 461.767 uV, v_off_fin = 471.480 uV 15:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.743 uVs 15:04:08 Integrated Voltage Measurement... 15:04:17 Voltage Offset Correction: v_off_ini = 467.136 uV, v_off_fin = 451.131 uV 15:04:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.295 uVs 15:04:19 I2Y Average and RMS of Measurements VT = -318.508 +- 8.896 uVs I2Y = -29.303 +- 0.818 uTm^2 15:04:27 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:04:31 Integrated Voltage Measurement... 15:04:40 Voltage Offset Correction: v_off_ini = 459.697 uV, v_off_fin = 454.015 uV 15:04:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -48.496 uVs 15:04:40 Integrated Voltage Measurement... 15:04:49 Voltage Offset Correction: v_off_ini = 458.004 uV, v_off_fin = 469.475 uV 15:04:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.763 uVs 15:04:49 Integrated Voltage Measurement... 15:04:58 Voltage Offset Correction: v_off_ini = 467.365 uV, v_off_fin = 477.940 uV 15:04:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.214 uVs 15:04:58 Integrated Voltage Measurement... 15:05:07 Voltage Offset Correction: v_off_ini = 458.011 uV, v_off_fin = 475.856 uV 15:05:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.163 uVs 15:05:07 Integrated Voltage Measurement... 15:05:16 Voltage Offset Correction: v_off_ini = 465.514 uV, v_off_fin = 449.834 uV 15:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.137 uVs 15:05:16 Integrated Voltage Measurement... 15:05:25 Voltage Offset Correction: v_off_ini = 454.215 uV, v_off_fin = 460.673 uV 15:05:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.212 uVs 15:05:29 I1X Average and RMS of Measurements VT = -40.498 +- 3.093 uVs I1X = 8.100 +- 0.619 uTm 15:05:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:05:36 Integrated Voltage Measurement... 15:05:45 Voltage Offset Correction: v_off_ini = 462.387 uV, v_off_fin = 455.832 uV 15:05:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.601 uVs 15:05:45 Integrated Voltage Measurement... 15:05:54 Voltage Offset Correction: v_off_ini = 459.005 uV, v_off_fin = 478.070 uV 15:05:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.434 uVs 15:05:54 Integrated Voltage Measurement... 15:06:03 Voltage Offset Correction: v_off_ini = 468.952 uV, v_off_fin = 454.221 uV 15:06:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.129 uVs 15:06:03 Integrated Voltage Measurement... 15:06:12 Voltage Offset Correction: v_off_ini = 476.808 uV, v_off_fin = 476.830 uV 15:06:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.562 uVs 15:06:12 Integrated Voltage Measurement... 15:06:21 Voltage Offset Correction: v_off_ini = 463.215 uV, v_off_fin = 455.503 uV 15:06:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.144 uVs 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = 467.550 uV, v_off_fin = 467.097 uV 15:06:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.254 uVs 15:06:34 I1Y Average and RMS of Measurements VT = -210.854 +- 3.442 uVs I1Y = -42.171 +- 0.688 uTm 15:06:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:06:39 Integrated Voltage Measurement... 15:06:48 Voltage Offset Correction: v_off_ini = 444.063 uV, v_off_fin = 446.963 uV 15:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.547 uVs 15:06:49 Integrated Voltage Measurement... 15:06:57 Voltage Offset Correction: v_off_ini = 441.268 uV, v_off_fin = 450.080 uV 15:06:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.100 uVs 15:06:58 Integrated Voltage Measurement... 15:07:07 Voltage Offset Correction: v_off_ini = 451.946 uV, v_off_fin = 436.585 uV 15:07:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.450 uVs 15:07:07 Integrated Voltage Measurement... 15:07:16 Voltage Offset Correction: v_off_ini = 447.826 uV, v_off_fin = 437.697 uV 15:07:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.830 uVs 15:07:16 Integrated Voltage Measurement... 15:07:25 Voltage Offset Correction: v_off_ini = 441.274 uV, v_off_fin = 447.413 uV 15:07:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.533 uVs 15:07:25 Integrated Voltage Measurement... 15:07:34 Voltage Offset Correction: v_off_ini = 431.004 uV, v_off_fin = 452.063 uV 15:07:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.662 uVs 15:07:36 I2X Average and RMS of Measurements VT = -71.687 +- 12.173 uVs I2X = 6.595 +- 1.120 uTm^2 15:07:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:07:41 Integrated Voltage Measurement... 15:07:50 Voltage Offset Correction: v_off_ini = 457.844 uV, v_off_fin = 458.088 uV 15:07:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.881 uVs 15:07:50 Integrated Voltage Measurement... 15:07:59 Voltage Offset Correction: v_off_ini = 445.574 uV, v_off_fin = 454.560 uV 15:07:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.335 uVs 15:07:59 Integrated Voltage Measurement... 15:08:08 Voltage Offset Correction: v_off_ini = 453.094 uV, v_off_fin = 461.432 uV 15:08:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.013 uVs 15:08:08 Integrated Voltage Measurement... 15:08:17 Voltage Offset Correction: v_off_ini = 464.638 uV, v_off_fin = 464.966 uV 15:08:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.429 uVs 15:08:17 Integrated Voltage Measurement... 15:08:26 Voltage Offset Correction: v_off_ini = 482.884 uV, v_off_fin = 478.451 uV 15:08:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.895 uVs 15:08:26 Integrated Voltage Measurement... 15:08:35 Voltage Offset Correction: v_off_ini = 489.034 uV, v_off_fin = 473.116 uV 15:08:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.733 uVs 15:08:38 I2Y Average and RMS of Measurements VT = -332.547 +- 8.133 uVs I2Y = -30.594 +- 0.748 uTm^2 15:08:42 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:08:46 Integrated Voltage Measurement... 15:08:55 Voltage Offset Correction: v_off_ini = 482.881 uV, v_off_fin = 465.465 uV 15:08:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -46.640 uVs 15:08:55 Integrated Voltage Measurement... 15:09:04 Voltage Offset Correction: v_off_ini = 468.653 uV, v_off_fin = 478.037 uV 15:09:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.025 uVs 15:09:04 Integrated Voltage Measurement... 15:09:13 Voltage Offset Correction: v_off_ini = 482.082 uV, v_off_fin = 469.651 uV 15:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -44.146 uVs 15:09:13 Integrated Voltage Measurement... 15:09:22 Voltage Offset Correction: v_off_ini = 484.494 uV, v_off_fin = 486.590 uV 15:09:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.137 uVs 15:09:22 Integrated Voltage Measurement... 15:09:31 Voltage Offset Correction: v_off_ini = 482.094 uV, v_off_fin = 478.196 uV 15:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.785 uVs 15:09:31 Integrated Voltage Measurement... 15:09:40 Voltage Offset Correction: v_off_ini = 473.469 uV, v_off_fin = 481.903 uV 15:09:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.264 uVs 15:09:44 I1X Average and RMS of Measurements VT = -46.166 +- 9.675 uVs I1X = 9.234 +- 1.936 uTm 15:09:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:09:51 Integrated Voltage Measurement... 15:10:00 Voltage Offset Correction: v_off_ini = 467.096 uV, v_off_fin = 460.298 uV 15:10:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.912 uVs 15:10:00 Integrated Voltage Measurement... 15:10:09 Voltage Offset Correction: v_off_ini = 464.519 uV, v_off_fin = 481.196 uV 15:10:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.536 uVs 15:10:09 Integrated Voltage Measurement... 15:10:18 Voltage Offset Correction: v_off_ini = 472.045 uV, v_off_fin = 456.791 uV 15:10:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.229 uVs 15:10:18 Integrated Voltage Measurement... 15:10:27 Voltage Offset Correction: v_off_ini = 476.142 uV, v_off_fin = 492.569 uV 15:10:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.292 uVs 15:10:27 Integrated Voltage Measurement... 15:10:36 Voltage Offset Correction: v_off_ini = 486.832 uV, v_off_fin = 473.570 uV 15:10:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.590 uVs 15:10:36 Integrated Voltage Measurement... 15:10:45 Voltage Offset Correction: v_off_ini = 468.236 uV, v_off_fin = 463.255 uV 15:10:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.871 uVs 15:10:50 I1Y Average and RMS of Measurements VT = -215.905 +- 4.756 uVs I1Y = -43.181 +- 0.951 uTm 15:10:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:10:55 Integrated Voltage Measurement... 15:11:04 Voltage Offset Correction: v_off_ini = 456.260 uV, v_off_fin = 454.004 uV 15:11:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.896 uVs 15:11:04 Integrated Voltage Measurement... 15:11:13 Voltage Offset Correction: v_off_ini = 462.859 uV, v_off_fin = 462.952 uV 15:11:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 57.691 uVs 15:11:13 Integrated Voltage Measurement... 15:11:22 Voltage Offset Correction: v_off_ini = 449.272 uV, v_off_fin = 452.284 uV 15:11:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.985 uVs 15:11:22 Integrated Voltage Measurement... 15:11:31 Voltage Offset Correction: v_off_ini = 468.135 uV, v_off_fin = 473.871 uV 15:11:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.911 uVs 15:11:31 Integrated Voltage Measurement... 15:11:40 Voltage Offset Correction: v_off_ini = 481.673 uV, v_off_fin = 468.240 uV 15:11:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.911 uVs 15:11:40 Integrated Voltage Measurement... 15:11:49 Voltage Offset Correction: v_off_ini = 462.647 uV, v_off_fin = 466.636 uV 15:11:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.174 uVs 15:11:51 I2X Average and RMS of Measurements VT = -64.094 +- 4.439 uVs I2X = 5.897 +- 0.409 uTm^2 15:11:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:11:56 Integrated Voltage Measurement... 15:12:05 Voltage Offset Correction: v_off_ini = 458.312 uV, v_off_fin = 456.507 uV 15:12:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -326.853 uVs 15:12:05 Integrated Voltage Measurement... 15:12:14 Voltage Offset Correction: v_off_ini = 459.841 uV, v_off_fin = 462.419 uV 15:12:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.682 uVs 15:12:14 Integrated Voltage Measurement... 15:12:23 Voltage Offset Correction: v_off_ini = 455.772 uV, v_off_fin = 460.354 uV 15:12:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.240 uVs 15:12:23 Integrated Voltage Measurement... 15:12:32 Voltage Offset Correction: v_off_ini = 460.431 uV, v_off_fin = 463.118 uV 15:12:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.780 uVs 15:12:33 Integrated Voltage Measurement... 15:12:41 Voltage Offset Correction: v_off_ini = 461.388 uV, v_off_fin = 459.248 uV 15:12:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.574 uVs 15:12:42 Integrated Voltage Measurement... 15:12:51 Voltage Offset Correction: v_off_ini = 458.481 uV, v_off_fin = 452.694 uV 15:12:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.326 uVs 15:12:53 I2Y Average and RMS of Measurements VT = -330.076 +- 4.020 uVs I2Y = -30.367 +- 0.370 uTm^2 15:12:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:01 Integrated Voltage Measurement... 15:13:10 Voltage Offset Correction: v_off_ini = 462.743 uV, v_off_fin = 446.412 uV 15:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -49.096 uVs 15:13:10 Integrated Voltage Measurement... 15:13:19 Voltage Offset Correction: v_off_ini = 447.624 uV, v_off_fin = 463.197 uV 15:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.087 uVs 15:13:19 Integrated Voltage Measurement... 15:13:28 Voltage Offset Correction: v_off_ini = 453.122 uV, v_off_fin = 449.570 uV 15:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.805 uVs 15:13:28 Integrated Voltage Measurement... 15:13:37 Voltage Offset Correction: v_off_ini = 454.733 uV, v_off_fin = 458.376 uV 15:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.664 uVs 15:13:37 Integrated Voltage Measurement... 15:13:46 Voltage Offset Correction: v_off_ini = 452.676 uV, v_off_fin = 448.457 uV 15:13:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.627 uVs 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 450.251 uV, v_off_fin = 460.510 uV 15:13:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.757 uVs 15:14:00 I1X Average and RMS of Measurements VT = -46.006 +- 9.741 uVs I1X = 9.201 +- 1.948 uTm 15:14:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:06 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = 447.756 uV, v_off_fin = 443.303 uV 15:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.818 uVs 15:14:15 Integrated Voltage Measurement... 15:14:24 Voltage Offset Correction: v_off_ini = 452.038 uV, v_off_fin = 442.200 uV 15:14:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.438 uVs 15:14:24 Integrated Voltage Measurement... 15:14:33 Voltage Offset Correction: v_off_ini = 438.690 uV, v_off_fin = 437.987 uV 15:14:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.796 uVs 15:14:33 Integrated Voltage Measurement... 15:14:42 Voltage Offset Correction: v_off_ini = 466.356 uV, v_off_fin = 478.100 uV 15:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.286 uVs 15:14:42 Integrated Voltage Measurement... 15:14:51 Voltage Offset Correction: v_off_ini = 456.139 uV, v_off_fin = 454.309 uV 15:14:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.563 uVs 15:14:51 Integrated Voltage Measurement... 15:15:00 Voltage Offset Correction: v_off_ini = 462.612 uV, v_off_fin = 469.344 uV 15:15:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.959 uVs 15:15:05 I1Y Average and RMS of Measurements VT = -210.643 +- 1.689 uVs I1Y = -42.129 +- 0.338 uTm 15:15:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:10 Integrated Voltage Measurement... 15:15:19 Voltage Offset Correction: v_off_ini = 472.565 uV, v_off_fin = 455.111 uV 15:15:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.018 uVs 15:15:19 Integrated Voltage Measurement... 15:15:28 Voltage Offset Correction: v_off_ini = 459.202 uV, v_off_fin = 464.316 uV 15:15:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.740 uVs 15:15:28 Integrated Voltage Measurement... 15:15:37 Voltage Offset Correction: v_off_ini = 471.912 uV, v_off_fin = 458.041 uV 15:15:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -86.994 uVs 15:15:37 Integrated Voltage Measurement... 15:15:46 Voltage Offset Correction: v_off_ini = 470.111 uV, v_off_fin = 468.440 uV 15:15:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.145 uVs 15:15:46 Integrated Voltage Measurement... 15:15:55 Voltage Offset Correction: v_off_ini = 475.779 uV, v_off_fin = 470.885 uV 15:15:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.444 uVs 15:15:55 Integrated Voltage Measurement... 15:16:04 Voltage Offset Correction: v_off_ini = 487.597 uV, v_off_fin = 502.549 uV 15:16:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.750 uVs 15:16:06 I2X Average and RMS of Measurements VT = -86.015 +- 4.656 uVs I2X = 7.914 +- 0.428 uTm^2 15:16:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:12 Integrated Voltage Measurement... 15:16:21 Voltage Offset Correction: v_off_ini = 487.906 uV, v_off_fin = 488.340 uV 15:16:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -337.146 uVs 15:16:21 Integrated Voltage Measurement... 15:16:30 Voltage Offset Correction: v_off_ini = 480.569 uV, v_off_fin = 470.176 uV 15:16:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.555 uVs 15:16:30 Integrated Voltage Measurement... 15:16:39 Voltage Offset Correction: v_off_ini = 463.257 uV, v_off_fin = 482.040 uV 15:16:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.195 uVs 15:16:39 Integrated Voltage Measurement... 15:16:48 Voltage Offset Correction: v_off_ini = 472.139 uV, v_off_fin = 484.560 uV 15:16:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.498 uVs 15:16:48 Integrated Voltage Measurement... 15:16:57 Voltage Offset Correction: v_off_ini = 494.150 uV, v_off_fin = 486.694 uV 15:16:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.462 uVs 15:16:57 Integrated Voltage Measurement... 15:17:06 Voltage Offset Correction: v_off_ini = 489.251 uV, v_off_fin = 490.810 uV 15:17:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 338.913 uVs 15:17:08 I2Y Average and RMS of Measurements VT = -330.295 +- 7.449 uVs I2Y = -30.388 +- 0.686 uTm^2 15:17:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:17:16 Integrated Voltage Measurement... 15:17:25 Voltage Offset Correction: v_off_ini = 500.414 uV, v_off_fin = 494.990 uV 15:17:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -40.268 uVs 15:17:26 Integrated Voltage Measurement... 15:17:34 Voltage Offset Correction: v_off_ini = 503.665 uV, v_off_fin = 505.591 uV 15:17:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 41.036 uVs 15:17:35 Integrated Voltage Measurement... 15:17:44 Voltage Offset Correction: v_off_ini = 494.003 uV, v_off_fin = 493.246 uV 15:17:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.778 uVs 15:17:44 Integrated Voltage Measurement... 15:17:53 Voltage Offset Correction: v_off_ini = 507.381 uV, v_off_fin = 515.069 uV 15:17:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 20.367 uVs 15:17:53 Integrated Voltage Measurement... 15:18:02 Voltage Offset Correction: v_off_ini = 514.534 uV, v_off_fin = 501.896 uV 15:18:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.479 uVs 15:18:02 Integrated Voltage Measurement... 15:18:11 Voltage Offset Correction: v_off_ini = 503.601 uV, v_off_fin = 504.033 uV 15:18:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.560 uVs 15:18:15 I1X Average and RMS of Measurements VT = -45.581 +- 12.321 uVs I1X = 9.117 +- 2.464 uTm 15:18:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:18:22 Integrated Voltage Measurement... 15:18:31 Voltage Offset Correction: v_off_ini = 494.748 uV, v_off_fin = 484.678 uV 15:18:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.430 uVs 15:18:31 Integrated Voltage Measurement... 15:18:40 Voltage Offset Correction: v_off_ini = 484.096 uV, v_off_fin = 484.956 uV 15:18:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.638 uVs 15:18:40 Integrated Voltage Measurement... 15:18:49 Voltage Offset Correction: v_off_ini = 477.441 uV, v_off_fin = 459.745 uV 15:18:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.340 uVs 15:18:49 Integrated Voltage Measurement... 15:18:58 Voltage Offset Correction: v_off_ini = 470.202 uV, v_off_fin = 491.316 uV 15:18:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.786 uVs 15:18:58 Integrated Voltage Measurement... 15:19:07 Voltage Offset Correction: v_off_ini = 471.982 uV, v_off_fin = 446.028 uV 15:19:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.506 uVs 15:19:07 Integrated Voltage Measurement... 15:19:16 Voltage Offset Correction: v_off_ini = 470.691 uV, v_off_fin = 470.758 uV 15:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.830 uVs 15:19:20 I1Y Average and RMS of Measurements VT = -206.922 +- 9.349 uVs I1Y = -41.382 +- 1.869 uTm 15:19:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:19:25 Integrated Voltage Measurement... 15:19:34 Voltage Offset Correction: v_off_ini = 462.181 uV, v_off_fin = 453.386 uV 15:19:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.986 uVs 15:19:34 Integrated Voltage Measurement... 15:19:43 Voltage Offset Correction: v_off_ini = 460.745 uV, v_off_fin = 455.765 uV 15:19:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.222 uVs 15:19:43 Integrated Voltage Measurement... 15:19:52 Voltage Offset Correction: v_off_ini = 463.655 uV, v_off_fin = 458.486 uV 15:19:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.776 uVs 15:19:52 Integrated Voltage Measurement... 15:20:01 Voltage Offset Correction: v_off_ini = 475.678 uV, v_off_fin = 470.500 uV 15:20:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.918 uVs 15:20:01 Integrated Voltage Measurement... 15:20:10 Voltage Offset Correction: v_off_ini = 480.723 uV, v_off_fin = 470.511 uV 15:20:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.149 uVs 15:20:10 Integrated Voltage Measurement... 15:20:19 Voltage Offset Correction: v_off_ini = 473.935 uV, v_off_fin = 488.133 uV 15:20:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.613 uVs 15:20:22 I2X Average and RMS of Measurements VT = -82.611 +- 7.103 uVs I2X = 7.600 +- 0.654 uTm^2 15:20:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:20:27 Integrated Voltage Measurement... 15:20:36 Voltage Offset Correction: v_off_ini = 487.893 uV, v_off_fin = 474.771 uV 15:20:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -303.817 uVs 15:20:36 Integrated Voltage Measurement... 15:20:45 Voltage Offset Correction: v_off_ini = 481.141 uV, v_off_fin = 480.917 uV 15:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.216 uVs 15:20:45 Integrated Voltage Measurement... 15:20:54 Voltage Offset Correction: v_off_ini = 481.206 uV, v_off_fin = 493.356 uV 15:20:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.161 uVs 15:20:54 Integrated Voltage Measurement... 15:21:03 Voltage Offset Correction: v_off_ini = 519.277 uV, v_off_fin = 485.869 uV 15:21:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.602 uVs 15:21:03 Integrated Voltage Measurement... 15:21:12 Voltage Offset Correction: v_off_ini = 485.572 uV, v_off_fin = 456.358 uV 15:21:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.363 uVs 15:21:12 Integrated Voltage Measurement... 15:21:21 Voltage Offset Correction: v_off_ini = 467.782 uV, v_off_fin = 480.674 uV 15:21:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.475 uVs 15:21:23 I2Y Average and RMS of Measurements VT = -323.272 +- 0.182 uVs I2Y = -29.742 +- 0.016 uTm^2 15:21:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:21:32 Integrated Voltage Measurement... 15:21:41 Voltage Offset Correction: v_off_ini = 452.787 uV, v_off_fin = 442.156 uV 15:21:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -56.317 uVs 15:21:41 Integrated Voltage Measurement... 15:21:50 Voltage Offset Correction: v_off_ini = 480.092 uV, v_off_fin = 473.441 uV 15:21:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.197 uVs 15:21:50 Integrated Voltage Measurement... 15:21:59 Voltage Offset Correction: v_off_ini = 501.794 uV, v_off_fin = 487.017 uV 15:21:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -27.498 uVs 15:21:59 Integrated Voltage Measurement... 15:22:08 Voltage Offset Correction: v_off_ini = 484.934 uV, v_off_fin = 483.356 uV 15:22:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.859 uVs 15:22:08 Integrated Voltage Measurement... 15:22:17 Voltage Offset Correction: v_off_ini = 485.394 uV, v_off_fin = 477.737 uV 15:22:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.156 uVs 15:22:17 Integrated Voltage Measurement... 15:22:26 Voltage Offset Correction: v_off_ini = 483.675 uV, v_off_fin = 495.385 uV 15:22:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.072 uVs 15:22:30 I1X Average and RMS of Measurements VT = -39.850 +- 6.420 uVs I1X = 7.970 +- 1.284 uTm 15:22:32 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:22:37 Integrated Voltage Measurement... 15:22:46 Voltage Offset Correction: v_off_ini = 479.237 uV, v_off_fin = 467.430 uV 15:22:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.177 uVs 15:22:46 Integrated Voltage Measurement... 15:22:55 Voltage Offset Correction: v_off_ini = 482.348 uV, v_off_fin = 496.462 uV 15:22:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.596 uVs 15:22:55 Integrated Voltage Measurement... 15:23:04 Voltage Offset Correction: v_off_ini = 480.645 uV, v_off_fin = 521.505 uV 15:23:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.128 uVs 15:23:04 Integrated Voltage Measurement... 15:23:13 Voltage Offset Correction: v_off_ini = 521.330 uV, v_off_fin = 503.451 uV 15:23:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.831 uVs 15:23:13 Integrated Voltage Measurement... 15:23:22 Voltage Offset Correction: v_off_ini = 470.676 uV, v_off_fin = 449.006 uV 15:23:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.237 uVs 15:23:22 Integrated Voltage Measurement... 15:23:31 Voltage Offset Correction: v_off_ini = 474.679 uV, v_off_fin = 469.887 uV 15:23:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.483 uVs 15:23:35 I1Y Average and RMS of Measurements VT = -203.909 +- 4.749 uVs I1Y = -40.782 +- 0.950 uTm 15:23:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:23:40 Integrated Voltage Measurement... 15:23:49 Voltage Offset Correction: v_off_ini = 448.270 uV, v_off_fin = 448.008 uV 15:23:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.962 uVs 15:23:49 Integrated Voltage Measurement... 15:23:58 Voltage Offset Correction: v_off_ini = 451.685 uV, v_off_fin = 457.968 uV 15:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.763 uVs 15:23:58 Integrated Voltage Measurement... 15:24:07 Voltage Offset Correction: v_off_ini = 455.514 uV, v_off_fin = 437.866 uV 15:24:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.970 uVs 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = 453.139 uV, v_off_fin = 460.515 uV 15:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.268 uVs 15:24:16 Integrated Voltage Measurement... 15:24:25 Voltage Offset Correction: v_off_ini = 460.408 uV, v_off_fin = 442.372 uV 15:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.594 uVs 15:24:25 Integrated Voltage Measurement... 15:24:34 Voltage Offset Correction: v_off_ini = 454.706 uV, v_off_fin = 463.781 uV 15:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.117 uVs 15:24:37 I2X Average and RMS of Measurements VT = -66.779 +- 0.719 uVs I2X = 6.144 +- 0.066 uTm^2 15:24:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:24:42 Integrated Voltage Measurement... 15:24:51 Voltage Offset Correction: v_off_ini = 446.054 uV, v_off_fin = 451.116 uV 15:24:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.189 uVs 15:24:51 Integrated Voltage Measurement... 15:25:00 Voltage Offset Correction: v_off_ini = 448.770 uV, v_off_fin = 445.746 uV 15:25:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.673 uVs 15:25:00 Integrated Voltage Measurement... 15:25:09 Voltage Offset Correction: v_off_ini = 459.618 uV, v_off_fin = 454.961 uV 15:25:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.362 uVs 15:25:09 Integrated Voltage Measurement... 15:25:18 Voltage Offset Correction: v_off_ini = 448.666 uV, v_off_fin = 432.554 uV 15:25:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.384 uVs 15:25:18 Integrated Voltage Measurement... 15:25:27 Voltage Offset Correction: v_off_ini = 434.947 uV, v_off_fin = 443.379 uV 15:25:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.665 uVs 15:25:27 Integrated Voltage Measurement... 15:25:36 Voltage Offset Correction: v_off_ini = 452.677 uV, v_off_fin = 456.252 uV 15:25:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.542 uVs 15:25:38 I2Y Average and RMS of Measurements VT = -323.136 +- 1.571 uVs I2Y = -29.728 +- 0.145 uTm^2 15:25:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:26:00 Integrated Voltage Measurement... 15:26:09 Voltage Offset Correction: v_off_ini = 448.130 uV, v_off_fin = 451.911 uV 15:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.645 uVs 15:26:09 Integrated Voltage Measurement... 15:26:18 Voltage Offset Correction: v_off_ini = 464.408 uV, v_off_fin = 463.926 uV 15:26:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.280 uVs 15:26:18 Integrated Voltage Measurement... 15:26:27 Voltage Offset Correction: v_off_ini = 466.364 uV, v_off_fin = 459.739 uV 15:26:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.784 uVs 15:26:27 Integrated Voltage Measurement... 15:26:36 Voltage Offset Correction: v_off_ini = 461.890 uV, v_off_fin = 462.980 uV 15:26:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.447 uVs 15:26:36 Integrated Voltage Measurement... 15:26:45 Voltage Offset Correction: v_off_ini = 449.874 uV, v_off_fin = 450.468 uV 15:26:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.018 uVs 15:26:45 Integrated Voltage Measurement... 15:26:54 Voltage Offset Correction: v_off_ini = 454.576 uV, v_off_fin = 443.878 uV 15:26:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.989 uVs 15:26:58 I1X Average and RMS of Measurements VT = -47.027 +- 2.512 uVs I1X = 9.405 +- 0.502 uTm 15:27:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:27:05 Integrated Voltage Measurement... 15:27:14 Voltage Offset Correction: v_off_ini = 457.480 uV, v_off_fin = 445.681 uV 15:27:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.817 uVs 15:27:14 Integrated Voltage Measurement... 15:27:23 Voltage Offset Correction: v_off_ini = 456.189 uV, v_off_fin = 460.583 uV 15:27:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.940 uVs 15:27:23 Integrated Voltage Measurement... 15:27:32 Voltage Offset Correction: v_off_ini = 440.513 uV, v_off_fin = 434.811 uV 15:27:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.136 uVs 15:27:32 Integrated Voltage Measurement... 15:27:41 Voltage Offset Correction: v_off_ini = 440.052 uV, v_off_fin = 450.025 uV 15:27:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.889 uVs 15:27:41 Integrated Voltage Measurement... 15:27:50 Voltage Offset Correction: v_off_ini = 434.905 uV, v_off_fin = 431.269 uV 15:27:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.579 uVs 15:27:50 Integrated Voltage Measurement... 15:27:59 Voltage Offset Correction: v_off_ini = 434.834 uV, v_off_fin = 442.834 uV 15:27:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.588 uVs 15:28:03 I1Y Average and RMS of Measurements VT = -214.325 +- 4.430 uVs I1Y = -42.865 +- 0.886 uTm 15:28:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:28:11 Integrated Voltage Measurement... 15:28:20 Voltage Offset Correction: v_off_ini = 442.048 uV, v_off_fin = 434.555 uV 15:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.451 uVs 15:28:20 Integrated Voltage Measurement... 15:28:29 Voltage Offset Correction: v_off_ini = 437.176 uV, v_off_fin = 437.375 uV 15:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.477 uVs 15:28:29 Integrated Voltage Measurement... 15:28:38 Voltage Offset Correction: v_off_ini = 427.353 uV, v_off_fin = 416.952 uV 15:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.772 uVs 15:28:38 Integrated Voltage Measurement... 15:28:47 Voltage Offset Correction: v_off_ini = 421.869 uV, v_off_fin = 444.056 uV 15:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.815 uVs 15:28:47 Integrated Voltage Measurement... 15:28:56 Voltage Offset Correction: v_off_ini = 433.844 uV, v_off_fin = 420.047 uV 15:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.391 uVs 15:28:56 Integrated Voltage Measurement... 15:29:05 Voltage Offset Correction: v_off_ini = 425.900 uV, v_off_fin = 428.333 uV 15:29:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.527 uVs 15:29:07 I2X Average and RMS of Measurements VT = -82.906 +- 2.867 uVs I2X = 7.627 +- 0.264 uTm^2 15:29:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:29:15 Integrated Voltage Measurement... 15:29:24 Voltage Offset Correction: v_off_ini = 426.136 uV, v_off_fin = 420.339 uV 15:29:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.939 uVs 15:29:24 Integrated Voltage Measurement... 15:29:33 Voltage Offset Correction: v_off_ini = 428.625 uV, v_off_fin = 422.736 uV 15:29:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.379 uVs 15:29:33 Integrated Voltage Measurement... 15:29:42 Voltage Offset Correction: v_off_ini = 426.642 uV, v_off_fin = 418.763 uV 15:29:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.910 uVs 15:29:42 Integrated Voltage Measurement... 15:29:51 Voltage Offset Correction: v_off_ini = 431.051 uV, v_off_fin = 437.275 uV 15:29:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.797 uVs 15:29:51 Integrated Voltage Measurement... 15:30:00 Voltage Offset Correction: v_off_ini = 427.508 uV, v_off_fin = 417.744 uV 15:30:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.085 uVs 15:30:00 Integrated Voltage Measurement... 15:30:09 Voltage Offset Correction: v_off_ini = 414.423 uV, v_off_fin = 427.292 uV 15:30:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.920 uVs 15:30:12 I2Y Average and RMS of Measurements VT = -327.505 +- 2.123 uVs I2Y = -30.130 +- 0.195 uTm^2 15:30:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:30:21 Integrated Voltage Measurement... 15:30:30 Voltage Offset Correction: v_off_ini = 424.425 uV, v_off_fin = 424.752 uV 15:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.617 uVs 15:30:30 Integrated Voltage Measurement... 15:30:39 Voltage Offset Correction: v_off_ini = 426.019 uV, v_off_fin = 425.525 uV 15:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.423 uVs 15:30:39 Integrated Voltage Measurement... 15:30:48 Voltage Offset Correction: v_off_ini = 417.794 uV, v_off_fin = 430.063 uV 15:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.394 uVs 15:30:48 Integrated Voltage Measurement... 15:30:57 Voltage Offset Correction: v_off_ini = 436.276 uV, v_off_fin = 438.947 uV 15:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.108 uVs 15:30:57 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = 427.432 uV, v_off_fin = 430.238 uV 15:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.725 uVs 15:31:06 Integrated Voltage Measurement... 15:31:15 Voltage Offset Correction: v_off_ini = 440.180 uV, v_off_fin = 437.828 uV 15:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.422 uVs 15:31:19 I1X Average and RMS of Measurements VT = -51.115 +- 9.610 uVs I1X = 10.223 +- 1.922 uTm 15:31:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:31:26 Integrated Voltage Measurement... 15:31:35 Voltage Offset Correction: v_off_ini = 432.443 uV, v_off_fin = 408.653 uV 15:31:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -211.678 uVs 15:31:35 Integrated Voltage Measurement... 15:31:44 Voltage Offset Correction: v_off_ini = 420.701 uV, v_off_fin = 428.369 uV 15:31:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.361 uVs 15:31:44 Integrated Voltage Measurement... 15:31:53 Voltage Offset Correction: v_off_ini = 426.025 uV, v_off_fin = 420.600 uV 15:31:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.372 uVs 15:31:53 Integrated Voltage Measurement... 15:32:02 Voltage Offset Correction: v_off_ini = 430.529 uV, v_off_fin = 421.130 uV 15:32:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.867 uVs 15:32:02 Integrated Voltage Measurement... 15:32:11 Voltage Offset Correction: v_off_ini = 435.324 uV, v_off_fin = 421.187 uV 15:32:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.277 uVs 15:32:11 Integrated Voltage Measurement... 15:32:20 Voltage Offset Correction: v_off_ini = 440.301 uV, v_off_fin = 440.903 uV 15:32:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.545 uVs 15:32:24 I1Y Average and RMS of Measurements VT = -219.017 +- 3.572 uVs I1Y = -43.804 +- 0.715 uTm 15:32:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:32:32 Integrated Voltage Measurement... 15:32:41 Voltage Offset Correction: v_off_ini = 431.539 uV, v_off_fin = 430.225 uV 15:32:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.235 uVs 15:32:41 Integrated Voltage Measurement... 15:32:50 Voltage Offset Correction: v_off_ini = 428.115 uV, v_off_fin = 444.946 uV 15:32:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.341 uVs 15:32:50 Integrated Voltage Measurement... 15:32:59 Voltage Offset Correction: v_off_ini = 425.093 uV, v_off_fin = 411.866 uV 15:32:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.773 uVs 15:32:59 Integrated Voltage Measurement... 15:33:08 Voltage Offset Correction: v_off_ini = 418.763 uV, v_off_fin = 439.755 uV 15:33:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.321 uVs 15:33:08 Integrated Voltage Measurement... 15:33:17 Voltage Offset Correction: v_off_ini = 414.402 uV, v_off_fin = 425.653 uV 15:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.295 uVs 15:33:17 Integrated Voltage Measurement... 15:33:26 Voltage Offset Correction: v_off_ini = 428.470 uV, v_off_fin = 426.633 uV 15:33:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.931 uVs 15:33:28 I2X Average and RMS of Measurements VT = -76.816 +- 7.527 uVs I2X = 7.067 +- 0.692 uTm^2 15:33:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:33:36 Integrated Voltage Measurement... 15:33:45 Voltage Offset Correction: v_off_ini = 403.069 uV, v_off_fin = 407.844 uV 15:33:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.825 uVs 15:33:45 Integrated Voltage Measurement... 15:33:54 Voltage Offset Correction: v_off_ini = 412.148 uV, v_off_fin = 420.992 uV 15:33:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 324.032 uVs 15:33:54 Integrated Voltage Measurement... 15:34:03 Voltage Offset Correction: v_off_ini = 424.030 uV, v_off_fin = 415.556 uV 15:34:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.630 uVs 15:34:03 Integrated Voltage Measurement... 15:34:12 Voltage Offset Correction: v_off_ini = 406.641 uV, v_off_fin = 398.389 uV 15:34:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.516 uVs 15:34:12 Integrated Voltage Measurement... 15:34:21 Voltage Offset Correction: v_off_ini = 406.315 uV, v_off_fin = 396.007 uV 15:34:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.984 uVs 15:34:21 Integrated Voltage Measurement... 15:34:30 Voltage Offset Correction: v_off_ini = 397.223 uV, v_off_fin = 408.487 uV 15:34:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.005 uVs 15:34:33 I2Y Average and RMS of Measurements VT = -315.999 +- 0.760 uVs I2Y = -29.072 +- 0.070 uTm^2 15:34:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = 393.431 uV, v_off_fin = 388.967 uV 15:34:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -67.664 uVs 15:34:51 Integrated Voltage Measurement... 15:34:59 Voltage Offset Correction: v_off_ini = 395.872 uV, v_off_fin = 387.340 uV 15:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.609 uVs 15:35:00 Integrated Voltage Measurement... 15:35:09 Voltage Offset Correction: v_off_ini = 382.379 uV, v_off_fin = 377.503 uV 15:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.154 uVs 15:35:09 Integrated Voltage Measurement... 15:35:18 Voltage Offset Correction: v_off_ini = 379.780 uV, v_off_fin = 382.807 uV 15:35:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.002 uVs 15:35:18 Integrated Voltage Measurement... 15:35:27 Voltage Offset Correction: v_off_ini = 382.877 uV, v_off_fin = 391.275 uV 15:35:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.142 uVs 15:35:27 Integrated Voltage Measurement... 15:35:36 Voltage Offset Correction: v_off_ini = 398.825 uV, v_off_fin = 404.784 uV 15:35:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.077 uVs 15:35:40 I1X Average and RMS of Measurements VT = -51.608 +- 4.702 uVs I1X = 10.322 +- 0.940 uTm 15:35:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:47 Integrated Voltage Measurement... 15:35:56 Voltage Offset Correction: v_off_ini = 402.441 uV, v_off_fin = 374.217 uV 15:35:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.619 uVs 15:35:56 Integrated Voltage Measurement... 15:36:05 Voltage Offset Correction: v_off_ini = 401.036 uV, v_off_fin = 408.437 uV 15:36:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.182 uVs 15:36:05 Integrated Voltage Measurement... 15:36:14 Voltage Offset Correction: v_off_ini = 399.935 uV, v_off_fin = 389.232 uV 15:36:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.052 uVs 15:36:14 Integrated Voltage Measurement... 15:36:23 Voltage Offset Correction: v_off_ini = 412.785 uV, v_off_fin = 420.351 uV 15:36:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.507 uVs 15:36:23 Integrated Voltage Measurement... 15:36:32 Voltage Offset Correction: v_off_ini = 421.608 uV, v_off_fin = 406.197 uV 15:36:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.066 uVs 15:36:32 Integrated Voltage Measurement... 15:36:41 Voltage Offset Correction: v_off_ini = 416.138 uV, v_off_fin = 421.890 uV 15:36:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.675 uVs 15:36:45 I1Y Average and RMS of Measurements VT = -209.684 +- 2.860 uVs I1Y = -41.937 +- 0.572 uTm 15:36:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:52 Integrated Voltage Measurement... 15:37:01 Voltage Offset Correction: v_off_ini = 411.094 uV, v_off_fin = 415.077 uV 15:37:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.107 uVs 15:37:02 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 427.775 uV, v_off_fin = 424.864 uV 15:37:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.547 uVs 15:37:11 Integrated Voltage Measurement... 15:37:20 Voltage Offset Correction: v_off_ini = 419.788 uV, v_off_fin = 408.514 uV 15:37:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.719 uVs 15:37:20 Integrated Voltage Measurement... 15:37:29 Voltage Offset Correction: v_off_ini = 425.590 uV, v_off_fin = 434.227 uV 15:37:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.577 uVs 15:37:29 Integrated Voltage Measurement... 15:37:38 Voltage Offset Correction: v_off_ini = 425.892 uV, v_off_fin = 410.821 uV 15:37:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.720 uVs 15:37:38 Integrated Voltage Measurement... 15:37:47 Voltage Offset Correction: v_off_ini = 415.761 uV, v_off_fin = 417.139 uV 15:37:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.229 uVs 15:37:49 I2X Average and RMS of Measurements VT = -67.817 +- 0.727 uVs I2X = 6.239 +- 0.067 uTm^2 15:37:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:57 Integrated Voltage Measurement... 15:38:06 Voltage Offset Correction: v_off_ini = 402.565 uV, v_off_fin = 389.104 uV 15:38:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.312 uVs 15:38:06 Integrated Voltage Measurement... 15:38:15 Voltage Offset Correction: v_off_ini = 397.459 uV, v_off_fin = 382.483 uV 15:38:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.411 uVs 15:38:15 Integrated Voltage Measurement... 15:38:24 Voltage Offset Correction: v_off_ini = 387.793 uV, v_off_fin = 389.282 uV 15:38:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.412 uVs 15:38:24 Integrated Voltage Measurement... 15:38:33 Voltage Offset Correction: v_off_ini = 398.665 uV, v_off_fin = 388.193 uV 15:38:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.463 uVs 15:38:33 Integrated Voltage Measurement... 15:38:42 Voltage Offset Correction: v_off_ini = 397.177 uV, v_off_fin = 392.678 uV 15:38:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.686 uVs 15:38:42 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = 404.330 uV, v_off_fin = 390.321 uV 15:38:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.273 uVs 15:38:53 I2Y Average and RMS of Measurements VT = -314.426 +- 6.954 uVs I2Y = -28.927 +- 0.640 uTm^2 15:38:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:39:02 Integrated Voltage Measurement... 15:39:11 Voltage Offset Correction: v_off_ini = 376.258 uV, v_off_fin = 375.243 uV 15:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.059 uVs 15:39:11 Integrated Voltage Measurement... 15:39:20 Voltage Offset Correction: v_off_ini = 386.393 uV, v_off_fin = 383.715 uV 15:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.415 uVs 15:39:20 Integrated Voltage Measurement... 15:39:29 Voltage Offset Correction: v_off_ini = 371.401 uV, v_off_fin = 372.441 uV 15:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.499 uVs 15:39:29 Integrated Voltage Measurement... 15:39:38 Voltage Offset Correction: v_off_ini = 360.095 uV, v_off_fin = 367.196 uV 15:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.271 uVs 15:39:38 Integrated Voltage Measurement... 15:39:47 Voltage Offset Correction: v_off_ini = 376.041 uV, v_off_fin = 365.163 uV 15:39:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.013 uVs 15:39:47 Integrated Voltage Measurement... 15:39:56 Voltage Offset Correction: v_off_ini = 361.664 uV, v_off_fin = 361.130 uV 15:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 31.940 uVs 15:40:01 I1X Average and RMS of Measurements VT = -45.199 +- 6.913 uVs I1X = 9.040 +- 1.382 uTm 15:40:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:40:07 Integrated Voltage Measurement... 15:40:16 Voltage Offset Correction: v_off_ini = 356.630 uV, v_off_fin = 354.124 uV 15:40:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.754 uVs 15:40:16 Integrated Voltage Measurement... 15:40:25 Voltage Offset Correction: v_off_ini = 357.066 uV, v_off_fin = 370.783 uV 15:40:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.787 uVs 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = 359.084 uV, v_off_fin = 354.029 uV 15:40:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.189 uVs 15:40:34 Integrated Voltage Measurement... 15:40:43 Voltage Offset Correction: v_off_ini = 363.730 uV, v_off_fin = 383.095 uV 15:40:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.497 uVs 15:40:44 Integrated Voltage Measurement... 15:40:52 Voltage Offset Correction: v_off_ini = 377.818 uV, v_off_fin = 347.643 uV 15:40:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.735 uVs 15:40:52 Integrated Voltage Measurement... 15:41:01 Voltage Offset Correction: v_off_ini = 357.545 uV, v_off_fin = 377.915 uV 15:41:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.072 uVs 15:41:06 I1Y Average and RMS of Measurements VT = -204.172 +- 3.437 uVs I1Y = -40.834 +- 0.687 uTm 15:41:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:41:13 Integrated Voltage Measurement... 15:41:22 Voltage Offset Correction: v_off_ini = 351.025 uV, v_off_fin = 351.330 uV 15:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.003 uVs 15:41:22 Integrated Voltage Measurement... 15:41:31 Voltage Offset Correction: v_off_ini = 362.440 uV, v_off_fin = 372.207 uV 15:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.755 uVs 15:41:32 Integrated Voltage Measurement... 15:41:40 Voltage Offset Correction: v_off_ini = 369.727 uV, v_off_fin = 352.200 uV 15:41:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.364 uVs 15:41:41 Integrated Voltage Measurement... 15:41:49 Voltage Offset Correction: v_off_ini = 373.696 uV, v_off_fin = 361.163 uV 15:41:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.869 uVs 15:41:50 Integrated Voltage Measurement... 15:41:59 Voltage Offset Correction: v_off_ini = 347.218 uV, v_off_fin = 349.265 uV 15:41:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.040 uVs 15:41:59 Integrated Voltage Measurement... 15:42:08 Voltage Offset Correction: v_off_ini = 354.508 uV, v_off_fin = 370.836 uV 15:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.438 uVs 15:42:10 I2X Average and RMS of Measurements VT = -75.245 +- 9.521 uVs I2X = 6.923 +- 0.876 uTm^2 15:42:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:42:18 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = 362.424 uV, v_off_fin = 365.866 uV 15:42:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.935 uVs 15:42:27 Integrated Voltage Measurement... 15:42:36 Voltage Offset Correction: v_off_ini = 355.646 uV, v_off_fin = 350.805 uV 15:42:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.590 uVs 15:42:36 Integrated Voltage Measurement... 15:42:45 Voltage Offset Correction: v_off_ini = 361.633 uV, v_off_fin = 355.753 uV 15:42:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -320.403 uVs 15:42:45 Integrated Voltage Measurement... 15:42:54 Voltage Offset Correction: v_off_ini = 361.592 uV, v_off_fin = 355.259 uV 15:42:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.394 uVs 15:42:54 Integrated Voltage Measurement... 15:43:03 Voltage Offset Correction: v_off_ini = 359.600 uV, v_off_fin = 361.278 uV 15:43:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.203 uVs 15:43:03 Integrated Voltage Measurement... 15:43:12 Voltage Offset Correction: v_off_ini = 357.716 uV, v_off_fin = 364.998 uV 15:43:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 313.463 uVs 15:43:14 I2Y Average and RMS of Measurements VT = -315.331 +- 5.977 uVs I2Y = -29.011 +- 0.549 uTm^2 15:43:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:43:23 Integrated Voltage Measurement... 15:43:32 Voltage Offset Correction: v_off_ini = 344.508 uV, v_off_fin = 343.588 uV 15:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.773 uVs 15:43:32 Integrated Voltage Measurement... 15:43:41 Voltage Offset Correction: v_off_ini = 347.913 uV, v_off_fin = 357.145 uV 15:43:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.488 uVs 15:43:41 Integrated Voltage Measurement... 15:43:50 Voltage Offset Correction: v_off_ini = 340.214 uV, v_off_fin = 334.541 uV 15:43:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.283 uVs 15:43:50 Integrated Voltage Measurement... 15:43:59 Voltage Offset Correction: v_off_ini = 350.288 uV, v_off_fin = 361.620 uV 15:43:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.699 uVs 15:43:59 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = 366.003 uV, v_off_fin = 352.142 uV 15:44:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.996 uVs 15:44:08 Integrated Voltage Measurement... 15:44:17 Voltage Offset Correction: v_off_ini = 372.799 uV, v_off_fin = 369.782 uV 15:44:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.711 uVs 15:44:22 I1X Average and RMS of Measurements VT = -42.992 +- 5.539 uVs I1X = 8.598 +- 1.108 uTm 15:44:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:44:28 Integrated Voltage Measurement... 15:44:37 Voltage Offset Correction: v_off_ini = 343.552 uV, v_off_fin = 335.661 uV 15:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.065 uVs 15:44:37 Integrated Voltage Measurement... 15:44:46 Voltage Offset Correction: v_off_ini = 328.082 uV, v_off_fin = 351.388 uV 15:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.399 uVs 15:44:46 Integrated Voltage Measurement... 15:44:55 Voltage Offset Correction: v_off_ini = 329.446 uV, v_off_fin = 312.234 uV 15:44:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.362 uVs 15:44:55 Integrated Voltage Measurement... 15:45:04 Voltage Offset Correction: v_off_ini = 327.104 uV, v_off_fin = 347.153 uV 15:45:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.394 uVs 15:45:04 Integrated Voltage Measurement... 15:45:13 Voltage Offset Correction: v_off_ini = 330.297 uV, v_off_fin = 325.052 uV 15:45:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.580 uVs 15:45:13 Integrated Voltage Measurement... 15:45:22 Voltage Offset Correction: v_off_ini = 329.373 uV, v_off_fin = 336.336 uV 15:45:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.575 uVs 15:45:27 I1Y Average and RMS of Measurements VT = -205.229 +- 6.774 uVs I1Y = -41.046 +- 1.355 uTm 15:45:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:45:34 Integrated Voltage Measurement... 15:45:43 Voltage Offset Correction: v_off_ini = 333.322 uV, v_off_fin = 334.125 uV 15:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.150 uVs 15:45:43 Integrated Voltage Measurement... 15:45:52 Voltage Offset Correction: v_off_ini = 329.807 uV, v_off_fin = 356.439 uV 15:45:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.383 uVs 15:45:52 Integrated Voltage Measurement... 15:46:01 Voltage Offset Correction: v_off_ini = 331.367 uV, v_off_fin = 318.779 uV 15:46:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.161 uVs 15:46:01 Integrated Voltage Measurement... 15:46:10 Voltage Offset Correction: v_off_ini = 319.241 uV, v_off_fin = 343.550 uV 15:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.282 uVs 15:46:10 Integrated Voltage Measurement... 15:46:19 Voltage Offset Correction: v_off_ini = 337.847 uV, v_off_fin = 321.133 uV 15:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.284 uVs 15:46:19 Integrated Voltage Measurement... 15:46:28 Voltage Offset Correction: v_off_ini = 329.882 uV, v_off_fin = 342.049 uV 15:46:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.572 uVs 15:46:31 I2X Average and RMS of Measurements VT = -65.472 +- 5.974 uVs I2X = 6.023 +- 0.550 uTm^2 15:46:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:46:39 Integrated Voltage Measurement... 15:46:48 Voltage Offset Correction: v_off_ini = 330.903 uV, v_off_fin = 331.218 uV 15:46:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.309 uVs 15:46:48 Integrated Voltage Measurement... 15:46:57 Voltage Offset Correction: v_off_ini = 339.042 uV, v_off_fin = 325.359 uV 15:46:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.832 uVs 15:46:57 Integrated Voltage Measurement... 15:47:06 Voltage Offset Correction: v_off_ini = 328.738 uV, v_off_fin = 318.199 uV 15:47:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.449 uVs 15:47:06 Integrated Voltage Measurement... 15:47:15 Voltage Offset Correction: v_off_ini = 317.111 uV, v_off_fin = 315.202 uV 15:47:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.340 uVs 15:47:15 Integrated Voltage Measurement... 15:47:24 Voltage Offset Correction: v_off_ini = 310.134 uV, v_off_fin = 307.787 uV 15:47:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.152 uVs 15:47:24 Integrated Voltage Measurement... 15:47:33 Voltage Offset Correction: v_off_ini = 306.486 uV, v_off_fin = 303.712 uV 15:47:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.235 uVs 15:47:35 I2Y Average and RMS of Measurements VT = -312.553 +- 1.098 uVs I2Y = -28.755 +- 0.101 uTm^2 15:47:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:47:47 Integrated Voltage Measurement... 15:47:56 Voltage Offset Correction: v_off_ini = 312.795 uV, v_off_fin = 301.069 uV 15:47:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -19.029 uVs 15:47:56 Integrated Voltage Measurement... 15:48:05 Voltage Offset Correction: v_off_ini = 307.342 uV, v_off_fin = 321.845 uV 15:48:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.099 uVs 15:48:05 Integrated Voltage Measurement... 15:48:14 Voltage Offset Correction: v_off_ini = 303.228 uV, v_off_fin = 310.495 uV 15:48:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -15.708 uVs 15:48:14 Integrated Voltage Measurement... 15:48:23 Voltage Offset Correction: v_off_ini = 315.699 uV, v_off_fin = 319.149 uV 15:48:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.121 uVs 15:48:23 Integrated Voltage Measurement... 15:48:32 Voltage Offset Correction: v_off_ini = 314.512 uV, v_off_fin = 308.410 uV 15:48:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.515 uVs 15:48:32 Integrated Voltage Measurement... 15:48:41 Voltage Offset Correction: v_off_ini = 306.478 uV, v_off_fin = 316.268 uV 15:48:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.528 uVs 15:48:46 I1X Average and RMS of Measurements VT = -27.000 +- 5.261 uVs I1X = 5.400 +- 1.052 uTm 15:48:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:48:52 Integrated Voltage Measurement... 15:49:01 Voltage Offset Correction: v_off_ini = 328.764 uV, v_off_fin = 305.960 uV 15:49:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.639 uVs 15:49:01 Integrated Voltage Measurement... 15:49:10 Voltage Offset Correction: v_off_ini = 314.836 uV, v_off_fin = 319.514 uV 15:49:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.579 uVs 15:49:10 Integrated Voltage Measurement... 15:49:19 Voltage Offset Correction: v_off_ini = 309.355 uV, v_off_fin = 298.424 uV 15:49:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.397 uVs 15:49:19 Integrated Voltage Measurement... 15:49:28 Voltage Offset Correction: v_off_ini = 315.948 uV, v_off_fin = 326.627 uV 15:49:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.593 uVs 15:49:28 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = 311.004 uV, v_off_fin = 298.097 uV 15:49:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.987 uVs 15:49:37 Integrated Voltage Measurement... 15:49:46 Voltage Offset Correction: v_off_ini = 312.943 uV, v_off_fin = 307.917 uV 15:49:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.635 uVs 15:49:51 I1Y Average and RMS of Measurements VT = -219.138 +- 3.208 uVs I1Y = -43.828 +- 0.642 uTm 15:49:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:49:56 Integrated Voltage Measurement... 15:50:05 Voltage Offset Correction: v_off_ini = 292.757 uV, v_off_fin = 294.134 uV 15:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.893 uVs 15:50:05 Integrated Voltage Measurement... 15:50:14 Voltage Offset Correction: v_off_ini = 299.931 uV, v_off_fin = 307.755 uV 15:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.171 uVs 15:50:14 Integrated Voltage Measurement... 15:50:23 Voltage Offset Correction: v_off_ini = 297.588 uV, v_off_fin = 294.887 uV 15:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.243 uVs 15:50:23 Integrated Voltage Measurement... 15:50:32 Voltage Offset Correction: v_off_ini = 307.085 uV, v_off_fin = 318.384 uV 15:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.145 uVs 15:50:32 Integrated Voltage Measurement... 15:50:41 Voltage Offset Correction: v_off_ini = 305.946 uV, v_off_fin = 293.409 uV 15:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.753 uVs 15:50:41 Integrated Voltage Measurement... 15:50:50 Voltage Offset Correction: v_off_ini = 311.025 uV, v_off_fin = 320.844 uV 15:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.693 uVs 15:50:52 I2X Average and RMS of Measurements VT = -61.316 +- 12.569 uVs I2X = 5.641 +- 1.156 uTm^2 15:50:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:50:57 Integrated Voltage Measurement... 15:51:06 Voltage Offset Correction: v_off_ini = 284.854 uV, v_off_fin = 283.066 uV 15:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.638 uVs 15:51:06 Integrated Voltage Measurement... 15:51:15 Voltage Offset Correction: v_off_ini = 293.641 uV, v_off_fin = 296.964 uV 15:51:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.424 uVs 15:51:16 Integrated Voltage Measurement... 15:51:24 Voltage Offset Correction: v_off_ini = 301.709 uV, v_off_fin = 291.306 uV 15:51:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -309.468 uVs 15:51:25 Integrated Voltage Measurement... 15:51:34 Voltage Offset Correction: v_off_ini = 303.546 uV, v_off_fin = 295.813 uV 15:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.924 uVs 15:51:34 Integrated Voltage Measurement... 15:51:43 Voltage Offset Correction: v_off_ini = 306.824 uV, v_off_fin = 298.387 uV 15:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.581 uVs 15:51:43 Integrated Voltage Measurement... 15:51:52 Voltage Offset Correction: v_off_ini = 291.641 uV, v_off_fin = 296.853 uV 15:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.780 uVs 15:51:54 I2Y Average and RMS of Measurements VT = -320.969 +- 5.108 uVs I2Y = -29.530 +- 0.469 uTm^2 15:51:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:52:02 Integrated Voltage Measurement... 15:52:11 Voltage Offset Correction: v_off_ini = 309.034 uV, v_off_fin = 292.723 uV 15:52:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.829 uVs 15:52:11 Integrated Voltage Measurement... 15:52:20 Voltage Offset Correction: v_off_ini = 292.707 uV, v_off_fin = 296.969 uV 15:52:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.954 uVs 15:52:20 Integrated Voltage Measurement... 15:52:29 Voltage Offset Correction: v_off_ini = 297.799 uV, v_off_fin = 294.082 uV 15:52:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.619 uVs 15:52:29 Integrated Voltage Measurement... 15:52:38 Voltage Offset Correction: v_off_ini = 295.105 uV, v_off_fin = 300.675 uV 15:52:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.619 uVs 15:52:38 Integrated Voltage Measurement... 15:52:47 Voltage Offset Correction: v_off_ini = 298.613 uV, v_off_fin = 299.237 uV 15:52:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.627 uVs 15:52:47 Integrated Voltage Measurement... 15:52:56 Voltage Offset Correction: v_off_ini = 313.954 uV, v_off_fin = 310.202 uV 15:52:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.648 uVs 15:53:01 I1X Average and RMS of Measurements VT = -41.883 +- 8.067 uVs I1X = 8.377 +- 1.613 uTm 15:53:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:53:07 Integrated Voltage Measurement... 15:53:16 Voltage Offset Correction: v_off_ini = 296.244 uV, v_off_fin = 295.205 uV 15:53:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.635 uVs 15:53:16 Integrated Voltage Measurement... 15:53:25 Voltage Offset Correction: v_off_ini = 299.945 uV, v_off_fin = 307.954 uV 15:53:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.868 uVs 15:53:26 Integrated Voltage Measurement... 15:53:34 Voltage Offset Correction: v_off_ini = 289.707 uV, v_off_fin = 287.505 uV 15:53:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.712 uVs 15:53:34 Integrated Voltage Measurement... 15:53:43 Voltage Offset Correction: v_off_ini = 300.711 uV, v_off_fin = 310.598 uV 15:53:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.414 uVs 15:53:44 Integrated Voltage Measurement... 15:53:52 Voltage Offset Correction: v_off_ini = 301.217 uV, v_off_fin = 286.457 uV 15:53:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.520 uVs 15:53:53 Integrated Voltage Measurement... 15:54:01 Voltage Offset Correction: v_off_ini = 285.325 uV, v_off_fin = 301.975 uV 15:54:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.881 uVs 15:54:06 I1Y Average and RMS of Measurements VT = -215.672 +- 3.557 uVs I1Y = -43.134 +- 0.711 uTm 15:54:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:54:11 Integrated Voltage Measurement... 15:54:20 Voltage Offset Correction: v_off_ini = 285.008 uV, v_off_fin = 283.905 uV 15:54:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.740 uVs 15:54:20 Integrated Voltage Measurement... 15:54:29 Voltage Offset Correction: v_off_ini = 288.297 uV, v_off_fin = 292.084 uV 15:54:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.317 uVs 15:54:29 Integrated Voltage Measurement... 15:54:38 Voltage Offset Correction: v_off_ini = 284.255 uV, v_off_fin = 284.672 uV 15:54:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.254 uVs 15:54:38 Integrated Voltage Measurement... 15:54:47 Voltage Offset Correction: v_off_ini = 280.951 uV, v_off_fin = 293.376 uV 15:54:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.941 uVs 15:54:47 Integrated Voltage Measurement... 15:54:56 Voltage Offset Correction: v_off_ini = 291.078 uV, v_off_fin = 285.377 uV 15:54:56 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.810 uVs 15:54:56 Integrated Voltage Measurement... 15:55:05 Voltage Offset Correction: v_off_ini = 296.783 uV, v_off_fin = 297.250 uV 15:55:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.149 uVs 15:55:07 I2X Average and RMS of Measurements VT = -67.868 +- 3.381 uVs I2X = 6.244 +- 0.311 uTm^2 15:55:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:55:13 Integrated Voltage Measurement... 15:55:22 Voltage Offset Correction: v_off_ini = 282.926 uV, v_off_fin = 287.467 uV 15:55:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.385 uVs 15:55:22 Integrated Voltage Measurement... 15:55:31 Voltage Offset Correction: v_off_ini = 293.503 uV, v_off_fin = 285.913 uV 15:55:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.161 uVs 15:55:31 Integrated Voltage Measurement... 15:55:40 Voltage Offset Correction: v_off_ini = 292.315 uV, v_off_fin = 282.829 uV 15:55:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.921 uVs 15:55:40 Integrated Voltage Measurement... 15:55:49 Voltage Offset Correction: v_off_ini = 291.941 uV, v_off_fin = 291.167 uV 15:55:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.651 uVs 15:55:49 Integrated Voltage Measurement... 15:55:58 Voltage Offset Correction: v_off_ini = 296.680 uV, v_off_fin = 285.092 uV 15:55:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.206 uVs 15:55:58 Integrated Voltage Measurement... 15:56:07 Voltage Offset Correction: v_off_ini = 297.888 uV, v_off_fin = 295.179 uV 15:56:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.130 uVs 15:56:09 I2Y Average and RMS of Measurements VT = -319.409 +- 3.921 uVs I2Y = -29.386 +- 0.361 uTm^2 15:56:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:18 Integrated Voltage Measurement... 15:56:27 Voltage Offset Correction: v_off_ini = 308.024 uV, v_off_fin = 296.742 uV 15:56:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.932 uVs 15:56:27 Integrated Voltage Measurement... 15:56:36 Voltage Offset Correction: v_off_ini = 299.162 uV, v_off_fin = 302.665 uV 15:56:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 25.614 uVs 15:56:36 Integrated Voltage Measurement... 15:56:45 Voltage Offset Correction: v_off_ini = 309.644 uV, v_off_fin = 308.181 uV 15:56:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.261 uVs 15:56:45 Integrated Voltage Measurement... 15:56:54 Voltage Offset Correction: v_off_ini = 305.266 uV, v_off_fin = 316.454 uV 15:56:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 72.691 uVs 15:56:54 Integrated Voltage Measurement... 15:57:03 Voltage Offset Correction: v_off_ini = 320.568 uV, v_off_fin = 303.163 uV 15:57:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.726 uVs 15:57:03 Integrated Voltage Measurement... 15:57:12 Voltage Offset Correction: v_off_ini = 315.407 uV, v_off_fin = 322.381 uV 15:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.508 uVs 15:57:16 I1X Average and RMS of Measurements VT = -47.955 +- 13.963 uVs I1X = 9.592 +- 2.793 uTm 15:57:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:23 Integrated Voltage Measurement... 15:57:32 Voltage Offset Correction: v_off_ini = 312.662 uV, v_off_fin = 299.761 uV 15:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.083 uVs 15:57:32 Integrated Voltage Measurement... 15:57:41 Voltage Offset Correction: v_off_ini = 330.393 uV, v_off_fin = 335.440 uV 15:57:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.330 uVs 15:57:41 Integrated Voltage Measurement... 15:57:50 Voltage Offset Correction: v_off_ini = 321.544 uV, v_off_fin = 313.087 uV 15:57:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.511 uVs 15:57:50 Integrated Voltage Measurement... 15:57:59 Voltage Offset Correction: v_off_ini = 325.419 uV, v_off_fin = 327.128 uV 15:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 196.154 uVs 15:57:59 Integrated Voltage Measurement... 15:58:08 Voltage Offset Correction: v_off_ini = 325.318 uV, v_off_fin = 316.068 uV 15:58:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.385 uVs 15:58:08 Integrated Voltage Measurement... 15:58:17 Voltage Offset Correction: v_off_ini = 325.654 uV, v_off_fin = 335.464 uV 15:58:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 207.805 uVs 15:58:21 I1Y Average and RMS of Measurements VT = -207.045 +- 2.365 uVs I1Y = -41.411 +- 0.474 uTm 15:58:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:26 Integrated Voltage Measurement... 15:58:35 Voltage Offset Correction: v_off_ini = 297.301 uV, v_off_fin = 293.290 uV 15:58:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.131 uVs 15:58:35 Integrated Voltage Measurement... 15:58:44 Voltage Offset Correction: v_off_ini = 302.718 uV, v_off_fin = 300.062 uV 15:58:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.390 uVs 15:58:44 Integrated Voltage Measurement... 15:58:53 Voltage Offset Correction: v_off_ini = 311.803 uV, v_off_fin = 305.507 uV 15:58:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.287 uVs 15:58:53 Integrated Voltage Measurement... 15:59:02 Voltage Offset Correction: v_off_ini = 312.912 uV, v_off_fin = 331.367 uV 15:59:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.472 uVs 15:59:02 Integrated Voltage Measurement... 15:59:11 Voltage Offset Correction: v_off_ini = 308.649 uV, v_off_fin = 300.498 uV 15:59:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.013 uVs 15:59:11 Integrated Voltage Measurement... 15:59:20 Voltage Offset Correction: v_off_ini = 305.164 uV, v_off_fin = 319.947 uV 15:59:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.242 uVs 15:59:23 I2X Average and RMS of Measurements VT = -79.422 +- 5.735 uVs I2X = 7.307 +- 0.528 uTm^2 15:59:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:28 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 297.173 uV, v_off_fin = 305.933 uV 15:59:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.862 uVs 15:59:37 Integrated Voltage Measurement... 15:59:46 Voltage Offset Correction: v_off_ini = 309.847 uV, v_off_fin = 308.576 uV 15:59:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.427 uVs 15:59:46 Integrated Voltage Measurement... 15:59:55 Voltage Offset Correction: v_off_ini = 311.810 uV, v_off_fin = 298.758 uV 15:59:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -310.550 uVs 15:59:55 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = 311.851 uV, v_off_fin = 318.287 uV 16:00:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.644 uVs 16:00:04 Integrated Voltage Measurement... 16:00:13 Voltage Offset Correction: v_off_ini = 322.952 uV, v_off_fin = 317.787 uV 16:00:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.871 uVs 16:00:13 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = 321.901 uV, v_off_fin = 341.272 uV 16:00:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 322.627 uVs 16:00:24 I2Y Average and RMS of Measurements VT = -320.163 +- 3.172 uVs I2Y = -29.456 +- 0.291 uTm^2 16:00:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:00:33 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = 341.191 uV, v_off_fin = 337.044 uV 16:00:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -48.594 uVs 16:00:42 Integrated Voltage Measurement... 16:00:51 Voltage Offset Correction: v_off_ini = 337.999 uV, v_off_fin = 337.989 uV 16:00:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 69.570 uVs 16:00:51 Integrated Voltage Measurement... 16:01:00 Voltage Offset Correction: v_off_ini = 324.102 uV, v_off_fin = 321.187 uV 16:01:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.717 uVs 16:01:00 Integrated Voltage Measurement... 16:01:09 Voltage Offset Correction: v_off_ini = 333.259 uV, v_off_fin = 343.855 uV 16:01:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 54.781 uVs 16:01:09 Integrated Voltage Measurement... 16:01:18 Voltage Offset Correction: v_off_ini = 338.566 uV, v_off_fin = 330.087 uV 16:01:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.569 uVs 16:01:18 Integrated Voltage Measurement... 16:01:27 Voltage Offset Correction: v_off_ini = 348.272 uV, v_off_fin = 326.567 uV 16:01:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.581 uVs 16:01:31 I1X Average and RMS of Measurements VT = -50.635 +- 8.753 uVs I1X = 10.128 +- 1.751 uTm 16:01:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:01:38 Integrated Voltage Measurement... 16:01:47 Voltage Offset Correction: v_off_ini = 313.180 uV, v_off_fin = 307.628 uV 16:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -203.039 uVs 16:01:47 Integrated Voltage Measurement... 16:01:56 Voltage Offset Correction: v_off_ini = 323.064 uV, v_off_fin = 322.801 uV 16:01:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.725 uVs 16:01:56 Integrated Voltage Measurement... 16:02:05 Voltage Offset Correction: v_off_ini = 318.257 uV, v_off_fin = 313.868 uV 16:02:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.005 uVs 16:02:05 Integrated Voltage Measurement... 16:02:14 Voltage Offset Correction: v_off_ini = 316.969 uV, v_off_fin = 330.494 uV 16:02:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 224.799 uVs 16:02:14 Integrated Voltage Measurement... 16:02:23 Voltage Offset Correction: v_off_ini = 324.013 uV, v_off_fin = 302.207 uV 16:02:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.699 uVs 16:02:23 Integrated Voltage Measurement... 16:02:32 Voltage Offset Correction: v_off_ini = 302.989 uV, v_off_fin = 310.799 uV 16:02:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.247 uVs 16:02:36 I1Y Average and RMS of Measurements VT = -211.586 +- 3.692 uVs I1Y = -42.317 +- 0.738 uTm 16:02:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:02:41 Integrated Voltage Measurement... 16:02:50 Voltage Offset Correction: v_off_ini = 308.123 uV, v_off_fin = 302.817 uV 16:02:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.353 uVs 16:02:50 Integrated Voltage Measurement... 16:02:59 Voltage Offset Correction: v_off_ini = 300.764 uV, v_off_fin = 322.023 uV 16:02:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.031 uVs 16:02:59 Integrated Voltage Measurement... 16:03:08 Voltage Offset Correction: v_off_ini = 300.895 uV, v_off_fin = 301.863 uV 16:03:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.110 uVs 16:03:08 Integrated Voltage Measurement... 16:03:17 Voltage Offset Correction: v_off_ini = 312.753 uV, v_off_fin = 319.734 uV 16:03:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.864 uVs 16:03:17 Integrated Voltage Measurement... 16:03:26 Voltage Offset Correction: v_off_ini = 319.931 uV, v_off_fin = 315.303 uV 16:03:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.283 uVs 16:03:26 Integrated Voltage Measurement... 16:03:35 Voltage Offset Correction: v_off_ini = 307.565 uV, v_off_fin = 323.683 uV 16:03:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.668 uVs 16:03:38 I2X Average and RMS of Measurements VT = -78.718 +- 6.360 uVs I2X = 7.242 +- 0.585 uTm^2 16:03:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:03:43 Integrated Voltage Measurement... 16:03:52 Voltage Offset Correction: v_off_ini = 317.224 uV, v_off_fin = 312.168 uV 16:03:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.431 uVs 16:03:52 Integrated Voltage Measurement... 16:04:01 Voltage Offset Correction: v_off_ini = 318.209 uV, v_off_fin = 314.451 uV 16:04:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.691 uVs 16:04:01 Integrated Voltage Measurement... 16:04:10 Voltage Offset Correction: v_off_ini = 300.714 uV, v_off_fin = 300.155 uV 16:04:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.731 uVs 16:04:10 Integrated Voltage Measurement... 16:04:19 Voltage Offset Correction: v_off_ini = 298.911 uV, v_off_fin = 302.940 uV 16:04:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.523 uVs 16:04:19 Integrated Voltage Measurement... 16:04:28 Voltage Offset Correction: v_off_ini = 315.990 uV, v_off_fin = 293.124 uV 16:04:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.521 uVs 16:04:28 Integrated Voltage Measurement... 16:04:37 Voltage Offset Correction: v_off_ini = 300.410 uV, v_off_fin = 318.330 uV 16:04:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.738 uVs 16:04:40 I2Y Average and RMS of Measurements VT = -310.439 +- 4.794 uVs I2Y = -28.560 +- 0.441 uTm^2 16:04:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:04:48 Integrated Voltage Measurement... 16:04:57 Voltage Offset Correction: v_off_ini = 309.762 uV, v_off_fin = 301.502 uV 16:04:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -32.902 uVs 16:04:57 Integrated Voltage Measurement... 16:05:06 Voltage Offset Correction: v_off_ini = 313.186 uV, v_off_fin = 295.371 uV 16:05:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.261 uVs 16:05:06 Integrated Voltage Measurement... 16:05:15 Voltage Offset Correction: v_off_ini = 321.174 uV, v_off_fin = 313.834 uV 16:05:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.155 uVs 16:05:15 Integrated Voltage Measurement... 16:05:24 Voltage Offset Correction: v_off_ini = 317.683 uV, v_off_fin = 304.456 uV 16:05:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.383 uVs 16:05:24 Integrated Voltage Measurement... 16:05:33 Voltage Offset Correction: v_off_ini = 286.321 uV, v_off_fin = 298.450 uV 16:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.191 uVs 16:05:33 Integrated Voltage Measurement... 16:05:42 Voltage Offset Correction: v_off_ini = 323.447 uV, v_off_fin = 319.940 uV 16:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.677 uVs 16:05:46 I1X Average and RMS of Measurements VT = -41.762 +- 4.557 uVs I1X = 8.353 +- 0.911 uTm 16:05:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:05:53 Integrated Voltage Measurement... 16:06:02 Voltage Offset Correction: v_off_ini = 292.245 uV, v_off_fin = 282.045 uV 16:06:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.908 uVs 16:06:02 Integrated Voltage Measurement... 16:06:11 Voltage Offset Correction: v_off_ini = 297.872 uV, v_off_fin = 310.020 uV 16:06:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.711 uVs 16:06:11 Integrated Voltage Measurement... 16:06:20 Voltage Offset Correction: v_off_ini = 296.024 uV, v_off_fin = 287.414 uV 16:06:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -216.477 uVs 16:06:20 Integrated Voltage Measurement... 16:06:29 Voltage Offset Correction: v_off_ini = 306.879 uV, v_off_fin = 311.566 uV 16:06:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.932 uVs 16:06:29 Integrated Voltage Measurement... 16:06:38 Voltage Offset Correction: v_off_ini = 300.069 uV, v_off_fin = 288.975 uV 16:06:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.843 uVs 16:06:38 Integrated Voltage Measurement... 16:06:47 Voltage Offset Correction: v_off_ini = 301.131 uV, v_off_fin = 304.029 uV 16:06:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.332 uVs 16:06:51 I1Y Average and RMS of Measurements VT = -211.701 +- 1.064 uVs I1Y = -42.340 +- 0.211 uTm 16:06:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:06:56 Integrated Voltage Measurement... 16:07:05 Voltage Offset Correction: v_off_ini = 284.875 uV, v_off_fin = 270.936 uV 16:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.660 uVs 16:07:06 Integrated Voltage Measurement... 16:07:14 Voltage Offset Correction: v_off_ini = 300.778 uV, v_off_fin = 304.653 uV 16:07:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.609 uVs 16:07:15 Integrated Voltage Measurement... 16:07:24 Voltage Offset Correction: v_off_ini = 289.371 uV, v_off_fin = 274.764 uV 16:07:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.207 uVs 16:07:24 Integrated Voltage Measurement... 16:07:33 Voltage Offset Correction: v_off_ini = 290.971 uV, v_off_fin = 293.639 uV 16:07:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.196 uVs 16:07:33 Integrated Voltage Measurement... 16:07:42 Voltage Offset Correction: v_off_ini = 295.184 uV, v_off_fin = 271.040 uV 16:07:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.242 uVs 16:07:42 Integrated Voltage Measurement... 16:07:51 Voltage Offset Correction: v_off_ini = 267.037 uV, v_off_fin = 278.494 uV 16:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.010 uVs 16:07:53 I2X Average and RMS of Measurements VT = -75.821 +- 0.863 uVs I2X = 6.976 +- 0.079 uTm^2 16:07:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:07:58 Integrated Voltage Measurement... 16:08:07 Voltage Offset Correction: v_off_ini = 274.677 uV, v_off_fin = 259.159 uV 16:08:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.230 uVs 16:08:07 Integrated Voltage Measurement... 16:08:16 Voltage Offset Correction: v_off_ini = 269.167 uV, v_off_fin = 266.223 uV 16:08:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.768 uVs 16:08:16 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = 261.036 uV, v_off_fin = 274.566 uV 16:08:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.151 uVs 16:08:25 Integrated Voltage Measurement... 16:08:34 Voltage Offset Correction: v_off_ini = 268.290 uV, v_off_fin = 275.150 uV 16:08:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.959 uVs 16:08:34 Integrated Voltage Measurement... 16:08:43 Voltage Offset Correction: v_off_ini = 255.880 uV, v_off_fin = 266.525 uV 16:08:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -322.755 uVs 16:08:43 Integrated Voltage Measurement... 16:08:52 Voltage Offset Correction: v_off_ini = 275.835 uV, v_off_fin = 282.704 uV 16:08:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.406 uVs 16:08:55 I2Y Average and RMS of Measurements VT = -310.211 +- 4.504 uVs I2Y = -28.540 +- 0.415 uTm^2 16:09:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:09:30 Integrated Voltage Measurement... 16:09:39 Voltage Offset Correction: v_off_ini = 280.999 uV, v_off_fin = 271.622 uV 16:09:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -95.428 uVs 16:09:39 Integrated Voltage Measurement... 16:09:48 Voltage Offset Correction: v_off_ini = 282.787 uV, v_off_fin = 282.896 uV 16:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.463 uVs 16:09:49 Integrated Voltage Measurement... 16:09:57 Voltage Offset Correction: v_off_ini = 282.062 uV, v_off_fin = 273.907 uV 16:09:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.679 uVs 16:09:58 Integrated Voltage Measurement... 16:10:06 Voltage Offset Correction: v_off_ini = 278.886 uV, v_off_fin = 282.630 uV 16:10:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.762 uVs 16:10:07 Integrated Voltage Measurement... 16:10:16 Voltage Offset Correction: v_off_ini = 283.963 uV, v_off_fin = 288.093 uV 16:10:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.745 uVs 16:10:16 Integrated Voltage Measurement... 16:10:25 Voltage Offset Correction: v_off_ini = 282.882 uV, v_off_fin = 282.139 uV 16:10:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.784 uVs 16:10:29 I1X Average and RMS of Measurements VT = -96.144 +- 7.740 uVs I1X = 19.230 +- 1.548 uTm 16:10:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:10:36 Integrated Voltage Measurement... 16:10:45 Voltage Offset Correction: v_off_ini = 282.212 uV, v_off_fin = 274.308 uV 16:10:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.535 uVs 16:10:45 Integrated Voltage Measurement... 16:10:54 Voltage Offset Correction: v_off_ini = 279.254 uV, v_off_fin = 304.679 uV 16:10:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.850 uVs 16:10:54 Integrated Voltage Measurement... 16:11:03 Voltage Offset Correction: v_off_ini = 293.179 uV, v_off_fin = 263.335 uV 16:11:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -189.075 uVs 16:11:03 Integrated Voltage Measurement... 16:11:12 Voltage Offset Correction: v_off_ini = 274.203 uV, v_off_fin = 285.053 uV 16:11:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.510 uVs 16:11:12 Integrated Voltage Measurement... 16:11:21 Voltage Offset Correction: v_off_ini = 263.327 uV, v_off_fin = 255.313 uV 16:11:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.733 uVs 16:11:21 Integrated Voltage Measurement... 16:11:30 Voltage Offset Correction: v_off_ini = 285.342 uV, v_off_fin = 292.207 uV 16:11:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.043 uVs 16:11:34 I1Y Average and RMS of Measurements VT = -194.624 +- 4.954 uVs I1Y = -38.925 +- 0.990 uTm 16:11:39 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:11:42 Integrated Voltage Measurement... 16:11:51 Voltage Offset Correction: v_off_ini = 287.368 uV, v_off_fin = 268.527 uV 16:11:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.085 uVs 16:11:51 Integrated Voltage Measurement... 16:12:00 Voltage Offset Correction: v_off_ini = 274.613 uV, v_off_fin = 284.150 uV 16:12:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.946 uVs 16:12:00 Integrated Voltage Measurement... 16:12:09 Voltage Offset Correction: v_off_ini = 276.120 uV, v_off_fin = 269.840 uV 16:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.507 uVs 16:12:09 Integrated Voltage Measurement... 16:12:18 Voltage Offset Correction: v_off_ini = 283.716 uV, v_off_fin = 288.538 uV 16:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.883 uVs 16:12:18 Integrated Voltage Measurement... 16:12:27 Voltage Offset Correction: v_off_ini = 298.871 uV, v_off_fin = 292.231 uV 16:12:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.070 uVs 16:12:27 Integrated Voltage Measurement... 16:12:36 Voltage Offset Correction: v_off_ini = 280.252 uV, v_off_fin = 284.387 uV 16:12:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.001 uVs 16:12:38 I2X Average and RMS of Measurements VT = -107.749 +- 5.175 uVs I2X = 9.913 +- 0.476 uTm^2 16:12:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:12:46 Integrated Voltage Measurement... 16:12:55 Voltage Offset Correction: v_off_ini = 269.287 uV, v_off_fin = 268.871 uV 16:12:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.151 uVs 16:12:55 Integrated Voltage Measurement... 16:13:04 Voltage Offset Correction: v_off_ini = 271.089 uV, v_off_fin = 265.191 uV 16:13:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.563 uVs 16:13:04 Integrated Voltage Measurement... 16:13:13 Voltage Offset Correction: v_off_ini = 267.521 uV, v_off_fin = 263.420 uV 16:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.948 uVs 16:13:13 Integrated Voltage Measurement... 16:13:22 Voltage Offset Correction: v_off_ini = 274.255 uV, v_off_fin = 258.912 uV 16:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.921 uVs 16:13:22 Integrated Voltage Measurement... 16:13:31 Voltage Offset Correction: v_off_ini = 272.484 uV, v_off_fin = 270.575 uV 16:13:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.640 uVs 16:13:31 Integrated Voltage Measurement... 16:13:40 Voltage Offset Correction: v_off_ini = 276.282 uV, v_off_fin = 275.441 uV 16:13:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.861 uVs 16:13:42 I2Y Average and RMS of Measurements VT = -231.847 +- 3.526 uVs I2Y = -21.330 +- 0.324 uTm^2 16:13:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:13:51 Integrated Voltage Measurement... 16:14:00 Voltage Offset Correction: v_off_ini = 254.037 uV, v_off_fin = 255.773 uV 16:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.092 uVs 16:14:00 Integrated Voltage Measurement... 16:14:09 Voltage Offset Correction: v_off_ini = 278.222 uV, v_off_fin = 261.635 uV 16:14:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.388 uVs 16:14:10 Integrated Voltage Measurement... 16:14:18 Voltage Offset Correction: v_off_ini = 260.466 uV, v_off_fin = 260.090 uV 16:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.226 uVs 16:14:19 Integrated Voltage Measurement... 16:14:27 Voltage Offset Correction: v_off_ini = 263.027 uV, v_off_fin = 260.920 uV 16:14:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.898 uVs 16:14:28 Integrated Voltage Measurement... 16:14:36 Voltage Offset Correction: v_off_ini = 269.010 uV, v_off_fin = 274.506 uV 16:14:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.300 uVs 16:14:37 Integrated Voltage Measurement... 16:14:45 Voltage Offset Correction: v_off_ini = 281.123 uV, v_off_fin = 271.794 uV 16:14:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.973 uVs 16:14:50 I1X Average and RMS of Measurements VT = -86.813 +- 4.133 uVs I1X = 17.363 +- 0.827 uTm 16:14:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:14:56 Integrated Voltage Measurement... 16:15:05 Voltage Offset Correction: v_off_ini = 268.738 uV, v_off_fin = 271.041 uV 16:15:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.836 uVs 16:15:05 Integrated Voltage Measurement... 16:15:14 Voltage Offset Correction: v_off_ini = 275.891 uV, v_off_fin = 279.424 uV 16:15:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.894 uVs 16:15:14 Integrated Voltage Measurement... 16:15:23 Voltage Offset Correction: v_off_ini = 269.546 uV, v_off_fin = 266.401 uV 16:15:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.210 uVs 16:15:23 Integrated Voltage Measurement... 16:15:32 Voltage Offset Correction: v_off_ini = 264.047 uV, v_off_fin = 279.530 uV 16:15:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.938 uVs 16:15:32 Integrated Voltage Measurement... 16:15:41 Voltage Offset Correction: v_off_ini = 275.364 uV, v_off_fin = 266.085 uV 16:15:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.914 uVs 16:15:41 Integrated Voltage Measurement... 16:15:50 Voltage Offset Correction: v_off_ini = 291.341 uV, v_off_fin = 284.042 uV 16:15:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.536 uVs 16:15:55 I1Y Average and RMS of Measurements VT = -186.221 +- 8.258 uVs I1Y = -37.244 +- 1.652 uTm 16:16:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:16:02 Integrated Voltage Measurement... 16:16:11 Voltage Offset Correction: v_off_ini = 266.164 uV, v_off_fin = 271.233 uV 16:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.578 uVs 16:16:11 Integrated Voltage Measurement... 16:16:20 Voltage Offset Correction: v_off_ini = 274.180 uV, v_off_fin = 283.470 uV 16:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.311 uVs 16:16:20 Integrated Voltage Measurement... 16:16:29 Voltage Offset Correction: v_off_ini = 274.037 uV, v_off_fin = 269.427 uV 16:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.669 uVs 16:16:29 Integrated Voltage Measurement... 16:16:38 Voltage Offset Correction: v_off_ini = 276.213 uV, v_off_fin = 296.786 uV 16:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.917 uVs 16:16:38 Integrated Voltage Measurement... 16:16:47 Voltage Offset Correction: v_off_ini = 281.735 uV, v_off_fin = 268.338 uV 16:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.009 uVs 16:16:47 Integrated Voltage Measurement... 16:16:56 Voltage Offset Correction: v_off_ini = 268.895 uV, v_off_fin = 268.338 uV 16:16:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.877 uVs 16:16:59 I2X Average and RMS of Measurements VT = -109.727 +- 4.941 uVs I2X = 10.095 +- 0.455 uTm^2 16:17:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:17:07 Integrated Voltage Measurement... 16:17:15 Voltage Offset Correction: v_off_ini = 270.820 uV, v_off_fin = 277.237 uV 16:17:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.444 uVs 16:17:16 Integrated Voltage Measurement... 16:17:25 Voltage Offset Correction: v_off_ini = 265.625 uV, v_off_fin = 271.240 uV 16:17:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.307 uVs 16:17:25 Integrated Voltage Measurement... 16:17:34 Voltage Offset Correction: v_off_ini = 256.068 uV, v_off_fin = 256.100 uV 16:17:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.679 uVs 16:17:34 Integrated Voltage Measurement... 16:17:43 Voltage Offset Correction: v_off_ini = 283.712 uV, v_off_fin = 281.798 uV 16:17:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.259 uVs 16:17:43 Integrated Voltage Measurement... 16:17:52 Voltage Offset Correction: v_off_ini = 262.300 uV, v_off_fin = 265.267 uV 16:17:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.472 uVs 16:17:52 Integrated Voltage Measurement... 16:18:01 Voltage Offset Correction: v_off_ini = 265.597 uV, v_off_fin = 271.840 uV 16:18:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.344 uVs 16:18:03 I2Y Average and RMS of Measurements VT = -231.751 +- 1.931 uVs I2Y = -21.321 +- 0.178 uTm^2 16:18:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:12 Integrated Voltage Measurement... 16:18:21 Voltage Offset Correction: v_off_ini = 258.653 uV, v_off_fin = 257.912 uV 16:18:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.212 uVs 16:18:21 Integrated Voltage Measurement... 16:18:30 Voltage Offset Correction: v_off_ini = 240.873 uV, v_off_fin = 258.245 uV 16:18:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.170 uVs 16:18:30 Integrated Voltage Measurement... 16:18:39 Voltage Offset Correction: v_off_ini = 247.882 uV, v_off_fin = 256.097 uV 16:18:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.394 uVs 16:18:39 Integrated Voltage Measurement... 16:18:48 Voltage Offset Correction: v_off_ini = 266.776 uV, v_off_fin = 270.630 uV 16:18:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.271 uVs 16:18:48 Integrated Voltage Measurement... 16:18:57 Voltage Offset Correction: v_off_ini = 260.135 uV, v_off_fin = 255.578 uV 16:18:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.254 uVs 16:18:57 Integrated Voltage Measurement... 16:19:06 Voltage Offset Correction: v_off_ini = 248.200 uV, v_off_fin = 253.284 uV 16:19:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.212 uVs 16:19:10 I1X Average and RMS of Measurements VT = -89.919 +- 12.920 uVs I1X = 17.984 +- 2.584 uTm 16:19:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:17 Integrated Voltage Measurement... 16:19:26 Voltage Offset Correction: v_off_ini = 262.465 uV, v_off_fin = 252.233 uV 16:19:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.588 uVs 16:19:26 Integrated Voltage Measurement... 16:19:35 Voltage Offset Correction: v_off_ini = 269.544 uV, v_off_fin = 278.852 uV 16:19:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.084 uVs 16:19:35 Integrated Voltage Measurement... 16:19:44 Voltage Offset Correction: v_off_ini = 270.324 uV, v_off_fin = 249.625 uV 16:19:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.564 uVs 16:19:44 Integrated Voltage Measurement... 16:19:53 Voltage Offset Correction: v_off_ini = 250.562 uV, v_off_fin = 253.382 uV 16:19:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.180 uVs 16:19:53 Integrated Voltage Measurement... 16:20:02 Voltage Offset Correction: v_off_ini = 247.133 uV, v_off_fin = 232.115 uV 16:20:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.129 uVs 16:20:02 Integrated Voltage Measurement... 16:20:11 Voltage Offset Correction: v_off_ini = 238.483 uV, v_off_fin = 255.516 uV 16:20:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.913 uVs 16:20:15 I1Y Average and RMS of Measurements VT = -194.076 +- 2.669 uVs I1Y = -38.815 +- 0.534 uTm 16:20:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:23 Integrated Voltage Measurement... 16:20:32 Voltage Offset Correction: v_off_ini = 245.894 uV, v_off_fin = 252.492 uV 16:20:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.590 uVs 16:20:32 Integrated Voltage Measurement... 16:20:41 Voltage Offset Correction: v_off_ini = 255.035 uV, v_off_fin = 256.120 uV 16:20:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.419 uVs 16:20:41 Integrated Voltage Measurement... 16:20:50 Voltage Offset Correction: v_off_ini = 266.286 uV, v_off_fin = 253.717 uV 16:20:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.091 uVs 16:20:50 Integrated Voltage Measurement... 16:20:59 Voltage Offset Correction: v_off_ini = 252.694 uV, v_off_fin = 264.560 uV 16:20:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.860 uVs 16:20:59 Integrated Voltage Measurement... 16:21:08 Voltage Offset Correction: v_off_ini = 274.301 uV, v_off_fin = 260.994 uV 16:21:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.358 uVs 16:21:08 Integrated Voltage Measurement... 16:21:17 Voltage Offset Correction: v_off_ini = 260.885 uV, v_off_fin = 264.197 uV 16:21:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.895 uVs 16:21:19 I2X Average and RMS of Measurements VT = -107.202 +- 2.944 uVs I2X = 9.863 +- 0.271 uTm^2 16:21:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:27 Integrated Voltage Measurement... 16:21:36 Voltage Offset Correction: v_off_ini = 244.459 uV, v_off_fin = 247.493 uV 16:21:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.294 uVs 16:21:36 Integrated Voltage Measurement... 16:21:45 Voltage Offset Correction: v_off_ini = 263.653 uV, v_off_fin = 261.501 uV 16:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.509 uVs 16:21:45 Integrated Voltage Measurement... 16:21:54 Voltage Offset Correction: v_off_ini = 269.826 uV, v_off_fin = 266.638 uV 16:21:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.823 uVs 16:21:54 Integrated Voltage Measurement... 16:22:03 Voltage Offset Correction: v_off_ini = 264.003 uV, v_off_fin = 268.120 uV 16:22:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.610 uVs 16:22:03 Integrated Voltage Measurement... 16:22:12 Voltage Offset Correction: v_off_ini = 266.631 uV, v_off_fin = 254.603 uV 16:22:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.704 uVs 16:22:12 Integrated Voltage Measurement... 16:22:21 Voltage Offset Correction: v_off_ini = 260.754 uV, v_off_fin = 260.762 uV 16:22:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.156 uVs 16:22:23 I2Y Average and RMS of Measurements VT = -232.349 +- 3.419 uVs I2Y = -21.376 +- 0.315 uTm^2 16:22:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:22:32 Integrated Voltage Measurement... 16:22:41 Voltage Offset Correction: v_off_ini = 258.058 uV, v_off_fin = 239.857 uV 16:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.124 uVs 16:22:41 Integrated Voltage Measurement... 16:22:50 Voltage Offset Correction: v_off_ini = 251.051 uV, v_off_fin = 253.001 uV 16:22:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.444 uVs 16:22:50 Integrated Voltage Measurement... 16:22:59 Voltage Offset Correction: v_off_ini = 250.260 uV, v_off_fin = 249.218 uV 16:22:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.113 uVs 16:22:59 Integrated Voltage Measurement... 16:23:08 Voltage Offset Correction: v_off_ini = 250.566 uV, v_off_fin = 255.702 uV 16:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.611 uVs 16:23:08 Integrated Voltage Measurement... 16:23:17 Voltage Offset Correction: v_off_ini = 256.394 uV, v_off_fin = 259.038 uV 16:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.369 uVs 16:23:17 Integrated Voltage Measurement... 16:23:26 Voltage Offset Correction: v_off_ini = 258.248 uV, v_off_fin = 247.035 uV 16:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.097 uVs 16:23:31 I1X Average and RMS of Measurements VT = -90.460 +- 4.121 uVs I1X = 18.093 +- 0.824 uTm 16:23:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:23:37 Integrated Voltage Measurement... 16:23:46 Voltage Offset Correction: v_off_ini = 241.245 uV, v_off_fin = 232.040 uV 16:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.978 uVs 16:23:46 Integrated Voltage Measurement... 16:23:55 Voltage Offset Correction: v_off_ini = 242.086 uV, v_off_fin = 254.707 uV 16:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.717 uVs 16:23:55 Integrated Voltage Measurement... 16:24:04 Voltage Offset Correction: v_off_ini = 249.442 uV, v_off_fin = 247.421 uV 16:24:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.268 uVs 16:24:04 Integrated Voltage Measurement... 16:24:13 Voltage Offset Correction: v_off_ini = 257.466 uV, v_off_fin = 272.296 uV 16:24:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.263 uVs 16:24:13 Integrated Voltage Measurement... 16:24:22 Voltage Offset Correction: v_off_ini = 263.083 uV, v_off_fin = 246.857 uV 16:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.793 uVs 16:24:22 Integrated Voltage Measurement... 16:24:31 Voltage Offset Correction: v_off_ini = 256.365 uV, v_off_fin = 261.222 uV 16:24:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.725 uVs 16:24:35 I1Y Average and RMS of Measurements VT = -189.957 +- 1.301 uVs I1Y = -37.991 +- 0.260 uTm 16:24:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:24:43 Integrated Voltage Measurement... 16:24:52 Voltage Offset Correction: v_off_ini = 245.214 uV, v_off_fin = 243.538 uV 16:24:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.545 uVs 16:24:52 Integrated Voltage Measurement... 16:25:01 Voltage Offset Correction: v_off_ini = 250.429 uV, v_off_fin = 264.656 uV 16:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.775 uVs 16:25:01 Integrated Voltage Measurement... 16:25:10 Voltage Offset Correction: v_off_ini = 259.839 uV, v_off_fin = 242.517 uV 16:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.483 uVs 16:25:10 Integrated Voltage Measurement... 16:25:19 Voltage Offset Correction: v_off_ini = 260.012 uV, v_off_fin = 260.076 uV 16:25:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.203 uVs 16:25:19 Integrated Voltage Measurement... 16:25:28 Voltage Offset Correction: v_off_ini = 274.547 uV, v_off_fin = 256.779 uV 16:25:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -119.236 uVs 16:25:28 Integrated Voltage Measurement... 16:25:37 Voltage Offset Correction: v_off_ini = 245.311 uV, v_off_fin = 256.110 uV 16:25:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.246 uVs 16:25:40 I2X Average and RMS of Measurements VT = -109.581 +- 6.649 uVs I2X = 10.082 +- 0.612 uTm^2 16:25:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:25:47 Integrated Voltage Measurement... 16:25:56 Voltage Offset Correction: v_off_ini = 252.921 uV, v_off_fin = 244.990 uV 16:25:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.149 uVs 16:25:56 Integrated Voltage Measurement... 16:26:05 Voltage Offset Correction: v_off_ini = 247.639 uV, v_off_fin = 238.652 uV 16:26:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.031 uVs 16:26:05 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = 240.085 uV, v_off_fin = 238.305 uV 16:26:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.555 uVs 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = 229.167 uV, v_off_fin = 237.972 uV 16:26:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.759 uVs 16:26:23 Integrated Voltage Measurement... 16:26:32 Voltage Offset Correction: v_off_ini = 214.012 uV, v_off_fin = 228.102 uV 16:26:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.492 uVs 16:26:32 Integrated Voltage Measurement... 16:26:41 Voltage Offset Correction: v_off_ini = 246.301 uV, v_off_fin = 239.358 uV 16:26:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.608 uVs 16:26:44 I2Y Average and RMS of Measurements VT = -227.432 +- 2.753 uVs I2Y = -20.924 +- 0.253 uTm^2 16:26:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:26:53 Integrated Voltage Measurement... 16:27:02 Voltage Offset Correction: v_off_ini = 247.035 uV, v_off_fin = 241.795 uV 16:27:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.592 uVs 16:27:02 Integrated Voltage Measurement... 16:27:11 Voltage Offset Correction: v_off_ini = 254.551 uV, v_off_fin = 251.125 uV 16:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.959 uVs 16:27:11 Integrated Voltage Measurement... 16:27:20 Voltage Offset Correction: v_off_ini = 256.938 uV, v_off_fin = 246.522 uV 16:27:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.638 uVs 16:27:20 Integrated Voltage Measurement... 16:27:29 Voltage Offset Correction: v_off_ini = 245.757 uV, v_off_fin = 258.336 uV 16:27:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.910 uVs 16:27:29 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 259.451 uV, v_off_fin = 258.883 uV 16:27:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.417 uVs 16:27:38 Integrated Voltage Measurement... 16:27:47 Voltage Offset Correction: v_off_ini = 248.161 uV, v_off_fin = 260.053 uV 16:27:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.453 uVs 16:27:51 I1X Average and RMS of Measurements VT = -94.162 +- 10.848 uVs I1X = 18.833 +- 2.170 uTm 16:27:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:27:58 Integrated Voltage Measurement... 16:28:07 Voltage Offset Correction: v_off_ini = 246.307 uV, v_off_fin = 232.829 uV 16:28:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.959 uVs 16:28:07 Integrated Voltage Measurement... 16:28:16 Voltage Offset Correction: v_off_ini = 241.187 uV, v_off_fin = 255.031 uV 16:28:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.790 uVs 16:28:16 Integrated Voltage Measurement... 16:28:25 Voltage Offset Correction: v_off_ini = 259.171 uV, v_off_fin = 247.305 uV 16:28:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.962 uVs 16:28:25 Integrated Voltage Measurement... 16:28:34 Voltage Offset Correction: v_off_ini = 253.087 uV, v_off_fin = 256.759 uV 16:28:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.497 uVs 16:28:34 Integrated Voltage Measurement... 16:28:43 Voltage Offset Correction: v_off_ini = 248.073 uV, v_off_fin = 246.207 uV 16:28:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.170 uVs 16:28:43 Integrated Voltage Measurement... 16:28:52 Voltage Offset Correction: v_off_ini = 253.519 uV, v_off_fin = 260.761 uV 16:28:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.630 uVs 16:28:56 I1Y Average and RMS of Measurements VT = -189.668 +- 0.397 uVs I1Y = -37.934 +- 0.079 uTm 16:29:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:29:03 Integrated Voltage Measurement... 16:29:12 Voltage Offset Correction: v_off_ini = 245.100 uV, v_off_fin = 241.210 uV 16:29:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.002 uVs 16:29:13 Integrated Voltage Measurement... 16:29:21 Voltage Offset Correction: v_off_ini = 232.996 uV, v_off_fin = 254.231 uV 16:29:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.001 uVs 16:29:22 Integrated Voltage Measurement... 16:29:30 Voltage Offset Correction: v_off_ini = 250.134 uV, v_off_fin = 230.761 uV 16:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.717 uVs 16:29:31 Integrated Voltage Measurement... 16:29:40 Voltage Offset Correction: v_off_ini = 234.430 uV, v_off_fin = 236.175 uV 16:29:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.801 uVs 16:29:40 Integrated Voltage Measurement... 16:29:49 Voltage Offset Correction: v_off_ini = 236.654 uV, v_off_fin = 238.992 uV 16:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.066 uVs 16:29:49 Integrated Voltage Measurement... 16:29:58 Voltage Offset Correction: v_off_ini = 262.902 uV, v_off_fin = 268.655 uV 16:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.036 uVs 16:30:00 I2X Average and RMS of Measurements VT = -103.104 +- 5.999 uVs I2X = 9.486 +- 0.552 uTm^2 16:30:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = 246.995 uV, v_off_fin = 255.959 uV 16:30:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -242.202 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = 256.316 uV, v_off_fin = 259.875 uV 16:30:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.024 uVs 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 271.426 uV, v_off_fin = 271.549 uV 16:30:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.965 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 274.900 uV, v_off_fin = 264.758 uV 16:30:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.011 uVs 16:30:44 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = 268.458 uV, v_off_fin = 249.671 uV 16:30:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.571 uVs 16:30:53 Integrated Voltage Measurement... 16:31:02 Voltage Offset Correction: v_off_ini = 250.562 uV, v_off_fin = 244.272 uV 16:31:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.277 uVs 16:31:04 I2Y Average and RMS of Measurements VT = -239.508 +- 8.506 uVs I2Y = -22.035 +- 0.783 uTm^2 16:31:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:31:16 Integrated Voltage Measurement... 16:31:25 Voltage Offset Correction: v_off_ini = 263.562 uV, v_off_fin = 266.469 uV 16:31:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.395 uVs 16:31:25 Integrated Voltage Measurement... 16:31:34 Voltage Offset Correction: v_off_ini = 263.504 uV, v_off_fin = 264.836 uV 16:31:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.184 uVs 16:31:34 Integrated Voltage Measurement... 16:31:43 Voltage Offset Correction: v_off_ini = 258.897 uV, v_off_fin = 267.686 uV 16:31:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.585 uVs 16:31:43 Integrated Voltage Measurement... 16:31:52 Voltage Offset Correction: v_off_ini = 248.567 uV, v_off_fin = 267.120 uV 16:31:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.958 uVs 16:31:52 Integrated Voltage Measurement... 16:32:01 Voltage Offset Correction: v_off_ini = 262.764 uV, v_off_fin = 251.067 uV 16:32:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.207 uVs 16:32:01 Integrated Voltage Measurement... 16:32:10 Voltage Offset Correction: v_off_ini = 263.637 uV, v_off_fin = 273.985 uV 16:32:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.846 uVs 16:32:14 I1X Average and RMS of Measurements VT = -86.863 +- 2.896 uVs I1X = 17.373 +- 0.579 uTm 16:32:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:32:21 Integrated Voltage Measurement... 16:32:30 Voltage Offset Correction: v_off_ini = 251.333 uV, v_off_fin = 253.028 uV 16:32:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.801 uVs 16:32:30 Integrated Voltage Measurement... 16:32:39 Voltage Offset Correction: v_off_ini = 257.723 uV, v_off_fin = 268.821 uV 16:32:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.227 uVs 16:32:39 Integrated Voltage Measurement... 16:32:48 Voltage Offset Correction: v_off_ini = 260.385 uV, v_off_fin = 246.440 uV 16:32:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.232 uVs 16:32:48 Integrated Voltage Measurement... 16:32:57 Voltage Offset Correction: v_off_ini = 267.191 uV, v_off_fin = 277.284 uV 16:32:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.540 uVs 16:32:57 Integrated Voltage Measurement... 16:33:06 Voltage Offset Correction: v_off_ini = 260.560 uV, v_off_fin = 252.728 uV 16:33:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.007 uVs 16:33:06 Integrated Voltage Measurement... 16:33:15 Voltage Offset Correction: v_off_ini = 256.205 uV, v_off_fin = 264.789 uV 16:33:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.225 uVs 16:33:19 I1Y Average and RMS of Measurements VT = -198.672 +- 4.682 uVs I1Y = -39.734 +- 0.936 uTm 16:33:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:33:24 Integrated Voltage Measurement... 16:33:33 Voltage Offset Correction: v_off_ini = 234.056 uV, v_off_fin = 234.424 uV 16:33:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.501 uVs 16:33:33 Integrated Voltage Measurement... 16:33:42 Voltage Offset Correction: v_off_ini = 244.873 uV, v_off_fin = 258.186 uV 16:33:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.096 uVs 16:33:42 Integrated Voltage Measurement... 16:33:51 Voltage Offset Correction: v_off_ini = 247.180 uV, v_off_fin = 244.084 uV 16:33:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.668 uVs 16:33:51 Integrated Voltage Measurement... 16:34:00 Voltage Offset Correction: v_off_ini = 259.788 uV, v_off_fin = 250.295 uV 16:34:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.308 uVs 16:34:01 Integrated Voltage Measurement... 16:34:09 Voltage Offset Correction: v_off_ini = 239.915 uV, v_off_fin = 239.289 uV 16:34:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.908 uVs 16:34:10 Integrated Voltage Measurement... 16:34:19 Voltage Offset Correction: v_off_ini = 259.976 uV, v_off_fin = 263.909 uV 16:34:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.234 uVs 16:34:21 I2X Average and RMS of Measurements VT = -95.786 +- 0.755 uVs I2X = 8.812 +- 0.070 uTm^2 16:34:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:34:26 Integrated Voltage Measurement... 16:34:35 Voltage Offset Correction: v_off_ini = 249.407 uV, v_off_fin = 248.437 uV 16:34:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.577 uVs 16:34:35 Integrated Voltage Measurement... 16:34:44 Voltage Offset Correction: v_off_ini = 241.990 uV, v_off_fin = 244.408 uV 16:34:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.369 uVs 16:34:44 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = 257.097 uV, v_off_fin = 236.120 uV 16:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.482 uVs 16:34:53 Integrated Voltage Measurement... 16:35:02 Voltage Offset Correction: v_off_ini = 250.686 uV, v_off_fin = 239.270 uV 16:35:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.433 uVs 16:35:02 Integrated Voltage Measurement... 16:35:11 Voltage Offset Correction: v_off_ini = 235.973 uV, v_off_fin = 231.953 uV 16:35:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.054 uVs 16:35:11 Integrated Voltage Measurement... 16:35:20 Voltage Offset Correction: v_off_ini = 229.482 uV, v_off_fin = 230.727 uV 16:35:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.876 uVs 16:35:23 I2Y Average and RMS of Measurements VT = -234.298 +- 2.252 uVs I2Y = -21.555 +- 0.207 uTm^2 16:35:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:35:31 Integrated Voltage Measurement... 16:35:40 Voltage Offset Correction: v_off_ini = 233.491 uV, v_off_fin = 238.201 uV 16:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.413 uVs 16:35:40 Integrated Voltage Measurement... 16:35:49 Voltage Offset Correction: v_off_ini = 228.101 uV, v_off_fin = 240.055 uV 16:35:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.818 uVs 16:35:49 Integrated Voltage Measurement... 16:35:58 Voltage Offset Correction: v_off_ini = 241.348 uV, v_off_fin = 221.896 uV 16:35:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -104.491 uVs 16:35:58 Integrated Voltage Measurement... 16:36:07 Voltage Offset Correction: v_off_ini = 232.325 uV, v_off_fin = 227.959 uV 16:36:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.747 uVs 16:36:07 Integrated Voltage Measurement... 16:36:16 Voltage Offset Correction: v_off_ini = 222.594 uV, v_off_fin = 215.070 uV 16:36:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -99.326 uVs 16:36:16 Integrated Voltage Measurement... 16:36:25 Voltage Offset Correction: v_off_ini = 219.810 uV, v_off_fin = 213.207 uV 16:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 90.163 uVs 16:36:29 I1X Average and RMS of Measurements VT = -87.993 +- 7.766 uVs I1X = 17.600 +- 1.554 uTm 16:36:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:36:36 Integrated Voltage Measurement... 16:36:45 Voltage Offset Correction: v_off_ini = 217.729 uV, v_off_fin = 209.366 uV 16:36:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -208.283 uVs 16:36:45 Integrated Voltage Measurement... 16:36:54 Voltage Offset Correction: v_off_ini = 216.831 uV, v_off_fin = 223.459 uV 16:36:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.404 uVs 16:36:54 Integrated Voltage Measurement... 16:37:03 Voltage Offset Correction: v_off_ini = 216.483 uV, v_off_fin = 217.992 uV 16:37:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.602 uVs 16:37:03 Integrated Voltage Measurement... 16:37:12 Voltage Offset Correction: v_off_ini = 225.350 uV, v_off_fin = 239.642 uV 16:37:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.264 uVs 16:37:12 Integrated Voltage Measurement... 16:37:21 Voltage Offset Correction: v_off_ini = 222.402 uV, v_off_fin = 207.582 uV 16:37:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.812 uVs 16:37:21 Integrated Voltage Measurement... 16:37:30 Voltage Offset Correction: v_off_ini = 207.557 uV, v_off_fin = 218.845 uV 16:37:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.412 uVs 16:37:34 I1Y Average and RMS of Measurements VT = -191.796 +- 4.048 uVs I1Y = -38.360 +- 0.811 uTm 16:37:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:37:39 Integrated Voltage Measurement... 16:37:48 Voltage Offset Correction: v_off_ini = 205.632 uV, v_off_fin = 189.761 uV 16:37:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.999 uVs 16:37:48 Integrated Voltage Measurement... 16:37:57 Voltage Offset Correction: v_off_ini = 206.612 uV, v_off_fin = 218.498 uV 16:37:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.714 uVs 16:37:57 Integrated Voltage Measurement... 16:38:06 Voltage Offset Correction: v_off_ini = 215.102 uV, v_off_fin = 199.376 uV 16:38:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.988 uVs 16:38:06 Integrated Voltage Measurement... 16:38:15 Voltage Offset Correction: v_off_ini = 213.345 uV, v_off_fin = 213.103 uV 16:38:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.623 uVs 16:38:15 Integrated Voltage Measurement... 16:38:24 Voltage Offset Correction: v_off_ini = 218.557 uV, v_off_fin = 207.053 uV 16:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.359 uVs 16:38:24 Integrated Voltage Measurement... 16:38:33 Voltage Offset Correction: v_off_ini = 204.530 uV, v_off_fin = 202.022 uV 16:38:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.574 uVs 16:38:36 I2X Average and RMS of Measurements VT = -103.376 +- 3.149 uVs I2X = 9.511 +- 0.290 uTm^2 16:38:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:38:41 Integrated Voltage Measurement... 16:38:50 Voltage Offset Correction: v_off_ini = 210.921 uV, v_off_fin = 204.659 uV 16:38:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.153 uVs 16:38:50 Integrated Voltage Measurement... 16:38:59 Voltage Offset Correction: v_off_ini = 210.231 uV, v_off_fin = 195.148 uV 16:38:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.029 uVs 16:38:59 Integrated Voltage Measurement... 16:39:08 Voltage Offset Correction: v_off_ini = 194.006 uV, v_off_fin = 195.716 uV 16:39:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.563 uVs 16:39:08 Integrated Voltage Measurement... 16:39:17 Voltage Offset Correction: v_off_ini = 187.752 uV, v_off_fin = 196.646 uV 16:39:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.705 uVs 16:39:17 Integrated Voltage Measurement... 16:39:26 Voltage Offset Correction: v_off_ini = 193.086 uV, v_off_fin = 194.475 uV 16:39:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.472 uVs 16:39:26 Integrated Voltage Measurement... 16:39:35 Voltage Offset Correction: v_off_ini = 194.603 uV, v_off_fin = 198.552 uV 16:39:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.721 uVs 16:39:37 I2Y Average and RMS of Measurements VT = -234.274 +- 2.653 uVs I2Y = -21.553 +- 0.244 uTm^2 16:39:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:46 Integrated Voltage Measurement... 16:39:55 Voltage Offset Correction: v_off_ini = 194.654 uV, v_off_fin = 187.618 uV 16:39:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.837 uVs 16:39:55 Integrated Voltage Measurement... 16:40:04 Voltage Offset Correction: v_off_ini = 187.885 uV, v_off_fin = 214.450 uV 16:40:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.420 uVs 16:40:04 Integrated Voltage Measurement... 16:40:13 Voltage Offset Correction: v_off_ini = 195.203 uV, v_off_fin = 202.673 uV 16:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.000 uVs 16:40:13 Integrated Voltage Measurement... 16:40:22 Voltage Offset Correction: v_off_ini = 201.474 uV, v_off_fin = 205.725 uV 16:40:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.436 uVs 16:40:22 Integrated Voltage Measurement... 16:40:31 Voltage Offset Correction: v_off_ini = 173.408 uV, v_off_fin = 178.976 uV 16:40:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.998 uVs 16:40:31 Integrated Voltage Measurement... 16:40:40 Voltage Offset Correction: v_off_ini = 186.796 uV, v_off_fin = 185.609 uV 16:40:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.463 uVs 16:40:44 I1X Average and RMS of Measurements VT = -81.026 +- 3.665 uVs I1X = 16.205 +- 0.733 uTm 16:40:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:51 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = 162.795 uV, v_off_fin = 143.277 uV 16:41:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.312 uVs 16:41:00 Integrated Voltage Measurement... 16:41:09 Voltage Offset Correction: v_off_ini = 184.229 uV, v_off_fin = 188.168 uV 16:41:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.456 uVs 16:41:09 Integrated Voltage Measurement... 16:41:18 Voltage Offset Correction: v_off_ini = 178.951 uV, v_off_fin = 171.714 uV 16:41:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.541 uVs 16:41:18 Integrated Voltage Measurement... 16:41:27 Voltage Offset Correction: v_off_ini = 183.892 uV, v_off_fin = 195.446 uV 16:41:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.677 uVs 16:41:27 Integrated Voltage Measurement... 16:41:36 Voltage Offset Correction: v_off_ini = 180.546 uV, v_off_fin = 178.255 uV 16:41:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.839 uVs 16:41:36 Integrated Voltage Measurement... 16:41:45 Voltage Offset Correction: v_off_ini = 191.096 uV, v_off_fin = 203.204 uV 16:41:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.492 uVs 16:41:49 I1Y Average and RMS of Measurements VT = -193.219 +- 2.615 uVs I1Y = -38.643 +- 0.525 uTm 16:41:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:54 Integrated Voltage Measurement... 16:42:03 Voltage Offset Correction: v_off_ini = 195.035 uV, v_off_fin = 181.069 uV 16:42:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.785 uVs 16:42:03 Integrated Voltage Measurement... 16:42:12 Voltage Offset Correction: v_off_ini = 206.533 uV, v_off_fin = 203.516 uV 16:42:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.436 uVs 16:42:12 Integrated Voltage Measurement... 16:42:21 Voltage Offset Correction: v_off_ini = 205.168 uV, v_off_fin = 188.645 uV 16:42:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.483 uVs 16:42:21 Integrated Voltage Measurement... 16:42:30 Voltage Offset Correction: v_off_ini = 200.848 uV, v_off_fin = 209.463 uV 16:42:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.187 uVs 16:42:30 Integrated Voltage Measurement... 16:42:39 Voltage Offset Correction: v_off_ini = 209.281 uV, v_off_fin = 202.652 uV 16:42:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.950 uVs 16:42:39 Integrated Voltage Measurement... 16:42:48 Voltage Offset Correction: v_off_ini = 211.389 uV, v_off_fin = 209.841 uV 16:42:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.979 uVs 16:42:51 I2X Average and RMS of Measurements VT = -97.303 +- 8.949 uVs I2X = 8.952 +- 0.823 uTm^2 16:42:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:56 Integrated Voltage Measurement... 16:43:05 Voltage Offset Correction: v_off_ini = 193.777 uV, v_off_fin = 187.743 uV 16:43:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.440 uVs 16:43:05 Integrated Voltage Measurement... 16:43:14 Voltage Offset Correction: v_off_ini = 180.078 uV, v_off_fin = 197.838 uV 16:43:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.353 uVs 16:43:14 Integrated Voltage Measurement... 16:43:23 Voltage Offset Correction: v_off_ini = 202.316 uV, v_off_fin = 202.805 uV 16:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.560 uVs 16:43:23 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = 195.180 uV, v_off_fin = 194.822 uV 16:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.125 uVs 16:43:32 Integrated Voltage Measurement... 16:43:41 Voltage Offset Correction: v_off_ini = 185.648 uV, v_off_fin = 188.972 uV 16:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.565 uVs 16:43:41 Integrated Voltage Measurement... 16:43:50 Voltage Offset Correction: v_off_ini = 197.411 uV, v_off_fin = 191.119 uV 16:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.165 uVs 16:43:52 I2Y Average and RMS of Measurements VT = -228.201 +- 9.122 uVs I2Y = -20.995 +- 0.839 uTm^2 16:43:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:44:01 Integrated Voltage Measurement... 16:44:10 Voltage Offset Correction: v_off_ini = 176.650 uV, v_off_fin = 194.525 uV 16:44:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.673 uVs 16:44:10 Integrated Voltage Measurement... 16:44:19 Voltage Offset Correction: v_off_ini = 187.589 uV, v_off_fin = 200.991 uV 16:44:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.540 uVs 16:44:19 Integrated Voltage Measurement... 16:44:28 Voltage Offset Correction: v_off_ini = 189.291 uV, v_off_fin = 180.900 uV 16:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.333 uVs 16:44:28 Integrated Voltage Measurement... 16:44:37 Voltage Offset Correction: v_off_ini = 215.885 uV, v_off_fin = 205.500 uV 16:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 98.547 uVs 16:44:37 Integrated Voltage Measurement... 16:44:46 Voltage Offset Correction: v_off_ini = 203.856 uV, v_off_fin = 188.693 uV 16:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.589 uVs 16:44:46 Integrated Voltage Measurement... 16:44:55 Voltage Offset Correction: v_off_ini = 218.776 uV, v_off_fin = 205.408 uV 16:44:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.468 uVs 16:44:59 I1X Average and RMS of Measurements VT = -91.692 +- 10.670 uVs I1X = 18.339 +- 2.134 uTm 16:45:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:45:06 Integrated Voltage Measurement... 16:45:15 Voltage Offset Correction: v_off_ini = 188.364 uV, v_off_fin = 163.269 uV 16:45:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.395 uVs 16:45:15 Integrated Voltage Measurement... 16:45:24 Voltage Offset Correction: v_off_ini = 194.434 uV, v_off_fin = 210.904 uV 16:45:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.273 uVs 16:45:24 Integrated Voltage Measurement... 16:45:33 Voltage Offset Correction: v_off_ini = 185.794 uV, v_off_fin = 172.026 uV 16:45:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.667 uVs 16:45:33 Integrated Voltage Measurement... 16:45:42 Voltage Offset Correction: v_off_ini = 180.481 uV, v_off_fin = 203.564 uV 16:45:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.960 uVs 16:45:42 Integrated Voltage Measurement... 16:45:51 Voltage Offset Correction: v_off_ini = 194.273 uV, v_off_fin = 176.512 uV 16:45:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.134 uVs 16:45:51 Integrated Voltage Measurement... 16:46:00 Voltage Offset Correction: v_off_ini = 182.563 uV, v_off_fin = 185.155 uV 16:46:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.588 uVs 16:46:04 I1Y Average and RMS of Measurements VT = -193.836 +- 7.374 uVs I1Y = -38.765 +- 1.477 uTm 16:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:46:09 Integrated Voltage Measurement... 16:46:18 Voltage Offset Correction: v_off_ini = 192.177 uV, v_off_fin = 169.865 uV 16:46:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.818 uVs 16:46:18 Integrated Voltage Measurement... 16:46:27 Voltage Offset Correction: v_off_ini = 171.556 uV, v_off_fin = 191.998 uV 16:46:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.557 uVs 16:46:27 Integrated Voltage Measurement... 16:46:36 Voltage Offset Correction: v_off_ini = 179.454 uV, v_off_fin = 169.131 uV 16:46:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.430 uVs 16:46:36 Integrated Voltage Measurement... 16:46:45 Voltage Offset Correction: v_off_ini = 165.902 uV, v_off_fin = 184.130 uV 16:46:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.681 uVs 16:46:45 Integrated Voltage Measurement... 16:46:54 Voltage Offset Correction: v_off_ini = 176.373 uV, v_off_fin = 160.932 uV 16:46:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.182 uVs 16:46:54 Integrated Voltage Measurement... 16:47:03 Voltage Offset Correction: v_off_ini = 166.800 uV, v_off_fin = 173.998 uV 16:47:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.479 uVs 16:47:06 I2X Average and RMS of Measurements VT = -104.025 +- 3.426 uVs I2X = 9.570 +- 0.315 uTm^2 16:47:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:47:11 Integrated Voltage Measurement... 16:47:20 Voltage Offset Correction: v_off_ini = 172.586 uV, v_off_fin = 175.796 uV 16:47:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.628 uVs 16:47:20 Integrated Voltage Measurement... 16:47:29 Voltage Offset Correction: v_off_ini = 180.045 uV, v_off_fin = 192.979 uV 16:47:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.830 uVs 16:47:29 Integrated Voltage Measurement... 16:47:38 Voltage Offset Correction: v_off_ini = 189.393 uV, v_off_fin = 187.532 uV 16:47:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.578 uVs 16:47:38 Integrated Voltage Measurement... 16:47:47 Voltage Offset Correction: v_off_ini = 185.821 uV, v_off_fin = 173.704 uV 16:47:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.874 uVs 16:47:47 Integrated Voltage Measurement... 16:47:56 Voltage Offset Correction: v_off_ini = 180.171 uV, v_off_fin = 167.882 uV 16:47:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.550 uVs 16:47:56 Integrated Voltage Measurement... 16:48:05 Voltage Offset Correction: v_off_ini = 179.269 uV, v_off_fin = 170.409 uV 16:48:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.557 uVs 16:48:07 I2Y Average and RMS of Measurements VT = -236.003 +- 8.660 uVs I2Y = -21.712 +- 0.797 uTm^2 16:48:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:48:15 Integrated Voltage Measurement... 16:48:24 Voltage Offset Correction: v_off_ini = 171.802 uV, v_off_fin = 160.694 uV 16:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.433 uVs 16:48:25 Integrated Voltage Measurement... 16:48:33 Voltage Offset Correction: v_off_ini = 183.916 uV, v_off_fin = 187.681 uV 16:48:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.136 uVs 16:48:34 Integrated Voltage Measurement... 16:48:42 Voltage Offset Correction: v_off_ini = 185.551 uV, v_off_fin = 172.690 uV 16:48:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.496 uVs 16:48:43 Integrated Voltage Measurement... 16:48:51 Voltage Offset Correction: v_off_ini = 173.327 uV, v_off_fin = 177.330 uV 16:48:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.017 uVs 16:48:52 Integrated Voltage Measurement... 16:49:00 Voltage Offset Correction: v_off_ini = 172.609 uV, v_off_fin = 174.449 uV 16:49:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.491 uVs 16:49:01 Integrated Voltage Measurement... 16:49:09 Voltage Offset Correction: v_off_ini = 168.473 uV, v_off_fin = 170.460 uV 16:49:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.824 uVs 16:49:14 I1X Average and RMS of Measurements VT = -80.066 +- 3.629 uVs I1X = 16.013 +- 0.726 uTm 16:49:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:49:20 Integrated Voltage Measurement... 16:49:29 Voltage Offset Correction: v_off_ini = 158.080 uV, v_off_fin = 153.148 uV 16:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.009 uVs 16:49:29 Integrated Voltage Measurement... 16:49:38 Voltage Offset Correction: v_off_ini = 154.891 uV, v_off_fin = 161.135 uV 16:49:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.383 uVs 16:49:38 Integrated Voltage Measurement... 16:49:47 Voltage Offset Correction: v_off_ini = 154.725 uV, v_off_fin = 139.940 uV 16:49:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.342 uVs 16:49:47 Integrated Voltage Measurement... 16:49:56 Voltage Offset Correction: v_off_ini = 149.437 uV, v_off_fin = 166.065 uV 16:49:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.629 uVs 16:49:56 Integrated Voltage Measurement... 16:50:05 Voltage Offset Correction: v_off_ini = 158.019 uV, v_off_fin = 141.637 uV 16:50:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.273 uVs 16:50:05 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = 166.394 uV, v_off_fin = 162.315 uV 16:50:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.222 uVs 16:50:19 I1Y Average and RMS of Measurements VT = -187.810 +- 2.839 uVs I1Y = -37.559 +- 0.568 uTm 16:50:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:50:24 Integrated Voltage Measurement... 16:50:33 Voltage Offset Correction: v_off_ini = 164.519 uV, v_off_fin = 151.954 uV 16:50:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.480 uVs 16:50:33 Integrated Voltage Measurement... 16:50:42 Voltage Offset Correction: v_off_ini = 173.199 uV, v_off_fin = 158.078 uV 16:50:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.303 uVs 16:50:42 Integrated Voltage Measurement... 16:50:51 Voltage Offset Correction: v_off_ini = 163.369 uV, v_off_fin = 164.493 uV 16:50:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.694 uVs 16:50:51 Integrated Voltage Measurement... 16:51:00 Voltage Offset Correction: v_off_ini = 171.138 uV, v_off_fin = 170.700 uV 16:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.407 uVs 16:51:00 Integrated Voltage Measurement... 16:51:09 Voltage Offset Correction: v_off_ini = 169.907 uV, v_off_fin = 159.070 uV 16:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.622 uVs 16:51:09 Integrated Voltage Measurement... 16:51:18 Voltage Offset Correction: v_off_ini = 184.005 uV, v_off_fin = 185.198 uV 16:51:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.682 uVs 16:51:20 I2X Average and RMS of Measurements VT = -98.365 +- 8.946 uVs I2X = 9.050 +- 0.823 uTm^2 16:51:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = 170.180 uV, v_off_fin = 155.733 uV 16:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.085 uVs 16:51:34 Integrated Voltage Measurement... 16:51:43 Voltage Offset Correction: v_off_ini = 165.562 uV, v_off_fin = 167.263 uV 16:51:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.946 uVs 16:51:43 Integrated Voltage Measurement... 16:51:52 Voltage Offset Correction: v_off_ini = 174.055 uV, v_off_fin = 173.596 uV 16:51:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.332 uVs 16:51:52 Integrated Voltage Measurement... 16:52:01 Voltage Offset Correction: v_off_ini = 175.723 uV, v_off_fin = 175.611 uV 16:52:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 241.603 uVs 16:52:01 Integrated Voltage Measurement... 16:52:10 Voltage Offset Correction: v_off_ini = 172.140 uV, v_off_fin = 167.973 uV 16:52:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.041 uVs 16:52:10 Integrated Voltage Measurement... 16:52:19 Voltage Offset Correction: v_off_ini = 175.173 uV, v_off_fin = 185.875 uV 16:52:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.888 uVs 16:52:22 I2Y Average and RMS of Measurements VT = -240.482 +- 3.102 uVs I2Y = -22.125 +- 0.285 uTm^2 16:52:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:01 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm