SLAC Magnetic Measurements Date: 11-21-2025 Time: 12:52:44 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16338 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 3 Measurement Device: Stretched Wire Operator: YL Comment: 12:52:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:54 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:52:55 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:52:57 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:52:58 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:53:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:13 Integrated Voltage Measurement... 12:53:22 Voltage Offset Correction: v_off_ini = 312.272 uV, v_off_fin = 308.824 uV 12:53:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.990 uVs 12:53:22 Integrated Voltage Measurement... 12:53:31 Voltage Offset Correction: v_off_ini = 312.976 uV, v_off_fin = 313.102 uV 12:53:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.467 uVs 12:53:31 Integrated Voltage Measurement... 12:53:40 Voltage Offset Correction: v_off_ini = 305.893 uV, v_off_fin = 294.299 uV 12:53:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.588 uVs 12:53:40 Integrated Voltage Measurement... 12:53:49 Voltage Offset Correction: v_off_ini = 310.311 uV, v_off_fin = 313.879 uV 12:53:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.385 uVs 12:53:49 Integrated Voltage Measurement... 12:53:58 Voltage Offset Correction: v_off_ini = 299.148 uV, v_off_fin = 309.552 uV 12:53:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -5.364 uVs 12:53:58 Integrated Voltage Measurement... 12:54:07 Voltage Offset Correction: v_off_ini = 315.824 uV, v_off_fin = 330.361 uV 12:54:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.894 uVs 12:54:11 I1X Average and RMS of Measurements VT = -43.615 +- 15.035 uVs I1X = 8.723 +- 3.007 uTm 12:54:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:54:18 Integrated Voltage Measurement... 12:54:27 Voltage Offset Correction: v_off_ini = 329.362 uV, v_off_fin = 294.133 uV 12:54:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.775 uVs 12:54:27 Integrated Voltage Measurement... 12:54:36 Voltage Offset Correction: v_off_ini = 307.406 uV, v_off_fin = 317.354 uV 12:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 149.511 uVs 12:54:36 Integrated Voltage Measurement... 12:54:45 Voltage Offset Correction: v_off_ini = 331.032 uV, v_off_fin = 308.368 uV 12:54:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.615 uVs 12:54:45 Integrated Voltage Measurement... 12:54:54 Voltage Offset Correction: v_off_ini = 309.378 uV, v_off_fin = 326.535 uV 12:54:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 143.523 uVs 12:54:54 Integrated Voltage Measurement... 12:55:03 Voltage Offset Correction: v_off_ini = 344.399 uV, v_off_fin = 313.724 uV 12:55:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.681 uVs 12:55:03 Integrated Voltage Measurement... 12:55:12 Voltage Offset Correction: v_off_ini = 315.010 uV, v_off_fin = 333.769 uV 12:55:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 133.290 uVs 12:55:16 I1Y Average and RMS of Measurements VT = -143.233 +- 4.081 uVs I1Y = -28.646 +- 0.816 uTm 12:55:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:55:24 Integrated Voltage Measurement... 12:55:33 Voltage Offset Correction: v_off_ini = 334.163 uV, v_off_fin = 309.664 uV 12:55:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.187 uVs 12:55:33 Integrated Voltage Measurement... 12:55:42 Voltage Offset Correction: v_off_ini = 327.315 uV, v_off_fin = 325.451 uV 12:55:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.020 uVs 12:55:42 Integrated Voltage Measurement... 12:55:51 Voltage Offset Correction: v_off_ini = 330.842 uV, v_off_fin = 318.832 uV 12:55:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -28.740 uVs 12:55:51 Integrated Voltage Measurement... 12:56:00 Voltage Offset Correction: v_off_ini = 325.629 uV, v_off_fin = 326.093 uV 12:56:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 25.875 uVs 12:56:00 Integrated Voltage Measurement... 12:56:09 Voltage Offset Correction: v_off_ini = 339.014 uV, v_off_fin = 326.084 uV 12:56:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.109 uVs 12:56:09 Integrated Voltage Measurement... 12:56:18 Voltage Offset Correction: v_off_ini = 327.873 uV, v_off_fin = 329.928 uV 12:56:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.055 uVs 12:56:20 I2X Average and RMS of Measurements VT = -34.831 +- 6.701 uVs I2X = 3.205 +- 0.616 uTm^2 12:56:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:56:28 Integrated Voltage Measurement... 12:56:37 Voltage Offset Correction: v_off_ini = 334.680 uV, v_off_fin = 341.084 uV 12:56:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.308 uVs 12:56:37 Integrated Voltage Measurement... 12:56:46 Voltage Offset Correction: v_off_ini = 319.070 uV, v_off_fin = 314.110 uV 12:56:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.644 uVs 12:56:46 Integrated Voltage Measurement... 12:56:55 Voltage Offset Correction: v_off_ini = 326.831 uV, v_off_fin = 326.079 uV 12:56:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.613 uVs 12:56:55 Integrated Voltage Measurement... 12:57:04 Voltage Offset Correction: v_off_ini = 324.736 uV, v_off_fin = 327.570 uV 12:57:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 198.373 uVs 12:57:04 Integrated Voltage Measurement... 12:57:13 Voltage Offset Correction: v_off_ini = 326.703 uV, v_off_fin = 326.130 uV 12:57:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.942 uVs 12:57:13 Integrated Voltage Measurement... 12:57:22 Voltage Offset Correction: v_off_ini = 341.094 uV, v_off_fin = 326.879 uV 12:57:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.308 uVs 12:57:25 I2Y Average and RMS of Measurements VT = -185.198 +- 1.294 uVs I2Y = -17.038 +- 0.119 uTm^2 12:57:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:57:40 Integrated Voltage Measurement... 12:57:49 Voltage Offset Correction: v_off_ini = 332.848 uV, v_off_fin = 351.629 uV 12:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.359 uVs 12:57:49 Integrated Voltage Measurement... 12:57:58 Voltage Offset Correction: v_off_ini = 365.978 uV, v_off_fin = 376.945 uV 12:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.077 uVs 12:57:58 Integrated Voltage Measurement... 12:58:07 Voltage Offset Correction: v_off_ini = 349.927 uV, v_off_fin = 365.721 uV 12:58:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.790 uVs 12:58:07 Integrated Voltage Measurement... 12:58:16 Voltage Offset Correction: v_off_ini = 369.842 uV, v_off_fin = 359.808 uV 12:58:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.385 uVs 12:58:16 Integrated Voltage Measurement... 12:58:25 Voltage Offset Correction: v_off_ini = 353.903 uV, v_off_fin = 357.504 uV 12:58:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.408 uVs 12:58:25 Integrated Voltage Measurement... 12:58:34 Voltage Offset Correction: v_off_ini = 359.264 uV, v_off_fin = 373.796 uV 12:58:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.332 uVs 12:58:38 I1X Average and RMS of Measurements VT = -62.559 +- 5.283 uVs I1X = 12.512 +- 1.057 uTm 12:58:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:58:45 Integrated Voltage Measurement... 12:58:54 Voltage Offset Correction: v_off_ini = 372.252 uV, v_off_fin = 371.324 uV 12:58:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -138.962 uVs 12:58:54 Integrated Voltage Measurement... 12:59:03 Voltage Offset Correction: v_off_ini = 365.248 uV, v_off_fin = 382.664 uV 12:59:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 153.411 uVs 12:59:03 Integrated Voltage Measurement... 12:59:12 Voltage Offset Correction: v_off_ini = 379.886 uV, v_off_fin = 379.434 uV 12:59:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.781 uVs 12:59:12 Integrated Voltage Measurement... 12:59:21 Voltage Offset Correction: v_off_ini = 390.973 uV, v_off_fin = 408.118 uV 12:59:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.838 uVs 12:59:21 Integrated Voltage Measurement... 12:59:30 Voltage Offset Correction: v_off_ini = 389.940 uV, v_off_fin = 383.660 uV 12:59:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.570 uVs 12:59:30 Integrated Voltage Measurement... 12:59:39 Voltage Offset Correction: v_off_ini = 402.557 uV, v_off_fin = 415.894 uV 12:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.717 uVs 12:59:43 I1Y Average and RMS of Measurements VT = -154.713 +- 6.212 uVs I1Y = -30.941 +- 1.244 uTm 12:59:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:59:51 Integrated Voltage Measurement... 13:00:00 Voltage Offset Correction: v_off_ini = 377.850 uV, v_off_fin = 370.312 uV 13:00:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.422 uVs 13:00:00 Integrated Voltage Measurement... 13:00:09 Voltage Offset Correction: v_off_ini = 377.590 uV, v_off_fin = 397.312 uV 13:00:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.722 uVs 13:00:09 Integrated Voltage Measurement... 13:00:18 Voltage Offset Correction: v_off_ini = 376.266 uV, v_off_fin = 376.946 uV 13:00:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.893 uVs 13:00:18 Integrated Voltage Measurement... 13:00:27 Voltage Offset Correction: v_off_ini = 387.212 uV, v_off_fin = 380.518 uV 13:00:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 47.108 uVs 13:00:27 Integrated Voltage Measurement... 13:00:36 Voltage Offset Correction: v_off_ini = 373.491 uV, v_off_fin = 373.926 uV 13:00:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.630 uVs 13:00:36 Integrated Voltage Measurement... 13:00:45 Voltage Offset Correction: v_off_ini = 390.463 uV, v_off_fin = 406.454 uV 13:00:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.629 uVs 13:00:48 I2X Average and RMS of Measurements VT = -50.234 +- 11.357 uVs I2X = 4.622 +- 1.045 uTm^2 13:00:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:55 Integrated Voltage Measurement... 13:01:04 Voltage Offset Correction: v_off_ini = 417.788 uV, v_off_fin = 409.693 uV 13:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.924 uVs 13:01:04 Integrated Voltage Measurement... 13:01:13 Voltage Offset Correction: v_off_ini = 398.790 uV, v_off_fin = 395.010 uV 13:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.330 uVs 13:01:13 Integrated Voltage Measurement... 13:01:22 Voltage Offset Correction: v_off_ini = 385.667 uV, v_off_fin = 384.867 uV 13:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.038 uVs 13:01:22 Integrated Voltage Measurement... 13:01:31 Voltage Offset Correction: v_off_ini = 397.498 uV, v_off_fin = 393.203 uV 13:01:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.210 uVs 13:01:31 Integrated Voltage Measurement... 13:01:40 Voltage Offset Correction: v_off_ini = 380.808 uV, v_off_fin = 415.004 uV 13:01:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.760 uVs 13:01:40 Integrated Voltage Measurement... 13:01:49 Voltage Offset Correction: v_off_ini = 418.184 uV, v_off_fin = 414.821 uV 13:01:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.279 uVs 13:01:52 I2Y Average and RMS of Measurements VT = -194.590 +- 2.406 uVs I2Y = -17.902 +- 0.221 uTm^2 13:02:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:02:07 Integrated Voltage Measurement... 13:02:16 Voltage Offset Correction: v_off_ini = 409.866 uV, v_off_fin = 410.483 uV 13:02:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.402 uVs 13:02:16 Integrated Voltage Measurement... 13:02:25 Voltage Offset Correction: v_off_ini = 404.757 uV, v_off_fin = 401.499 uV 13:02:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.816 uVs 13:02:25 Integrated Voltage Measurement... 13:02:34 Voltage Offset Correction: v_off_ini = 398.026 uV, v_off_fin = 399.586 uV 13:02:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.908 uVs 13:02:34 Integrated Voltage Measurement... 13:02:43 Voltage Offset Correction: v_off_ini = 404.031 uV, v_off_fin = 412.436 uV 13:02:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.648 uVs 13:02:43 Integrated Voltage Measurement... 13:02:52 Voltage Offset Correction: v_off_ini = 399.985 uV, v_off_fin = 397.901 uV 13:02:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.284 uVs 13:02:52 Integrated Voltage Measurement... 13:03:01 Voltage Offset Correction: v_off_ini = 389.855 uV, v_off_fin = 406.425 uV 13:03:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.443 uVs 13:03:05 I1X Average and RMS of Measurements VT = -77.917 +- 0.617 uVs I1X = 15.584 +- 0.123 uTm 13:03:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:12 Integrated Voltage Measurement... 13:03:21 Voltage Offset Correction: v_off_ini = 407.481 uV, v_off_fin = 392.562 uV 13:03:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -153.294 uVs 13:03:21 Integrated Voltage Measurement... 13:03:30 Voltage Offset Correction: v_off_ini = 414.682 uV, v_off_fin = 420.048 uV 13:03:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.994 uVs 13:03:30 Integrated Voltage Measurement... 13:03:39 Voltage Offset Correction: v_off_ini = 415.193 uV, v_off_fin = 414.644 uV 13:03:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -156.162 uVs 13:03:39 Integrated Voltage Measurement... 13:03:48 Voltage Offset Correction: v_off_ini = 426.609 uV, v_off_fin = 417.918 uV 13:03:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.385 uVs 13:03:48 Integrated Voltage Measurement... 13:03:57 Voltage Offset Correction: v_off_ini = 406.025 uV, v_off_fin = 404.956 uV 13:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.276 uVs 13:03:57 Integrated Voltage Measurement... 13:04:06 Voltage Offset Correction: v_off_ini = 418.738 uV, v_off_fin = 450.764 uV 13:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 170.636 uVs 13:04:10 I1Y Average and RMS of Measurements VT = -167.624 +- 3.811 uVs I1Y = -33.524 +- 0.762 uTm 13:04:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:04:18 Integrated Voltage Measurement... 13:04:27 Voltage Offset Correction: v_off_ini = 403.240 uV, v_off_fin = 399.938 uV 13:04:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.975 uVs 13:04:27 Integrated Voltage Measurement... 13:04:36 Voltage Offset Correction: v_off_ini = 407.824 uV, v_off_fin = 441.514 uV 13:04:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.718 uVs 13:04:36 Integrated Voltage Measurement... 13:04:45 Voltage Offset Correction: v_off_ini = 434.992 uV, v_off_fin = 437.539 uV 13:04:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.262 uVs 13:04:45 Integrated Voltage Measurement... 13:04:54 Voltage Offset Correction: v_off_ini = 439.292 uV, v_off_fin = 427.941 uV 13:04:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 67.640 uVs 13:04:54 Integrated Voltage Measurement... 13:05:03 Voltage Offset Correction: v_off_ini = 426.638 uV, v_off_fin = 410.174 uV 13:05:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.269 uVs 13:05:03 Integrated Voltage Measurement... 13:05:12 Voltage Offset Correction: v_off_ini = 433.481 uV, v_off_fin = 424.327 uV 13:05:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.433 uVs 13:05:15 I2X Average and RMS of Measurements VT = -66.716 +- 5.754 uVs I2X = 6.138 +- 0.529 uTm^2 13:05:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:22 Integrated Voltage Measurement... 13:05:31 Voltage Offset Correction: v_off_ini = 391.950 uV, v_off_fin = 413.027 uV 13:05:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.091 uVs 13:05:32 Integrated Voltage Measurement... 13:05:41 Voltage Offset Correction: v_off_ini = 421.323 uV, v_off_fin = 415.580 uV 13:05:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.675 uVs 13:05:41 Integrated Voltage Measurement... 13:05:50 Voltage Offset Correction: v_off_ini = 417.943 uV, v_off_fin = 412.583 uV 13:05:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.489 uVs 13:05:50 Integrated Voltage Measurement... 13:05:59 Voltage Offset Correction: v_off_ini = 418.397 uV, v_off_fin = 414.573 uV 13:05:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.517 uVs 13:05:59 Integrated Voltage Measurement... 13:06:08 Voltage Offset Correction: v_off_ini = 422.706 uV, v_off_fin = 415.229 uV 13:06:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.683 uVs 13:06:08 Integrated Voltage Measurement... 13:06:17 Voltage Offset Correction: v_off_ini = 416.496 uV, v_off_fin = 434.469 uV 13:06:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.692 uVs 13:06:19 I2Y Average and RMS of Measurements VT = -198.691 +- 5.152 uVs I2Y = -18.280 +- 0.474 uTm^2 13:06:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:34 Integrated Voltage Measurement... 13:06:43 Voltage Offset Correction: v_off_ini = 427.583 uV, v_off_fin = 410.094 uV 13:06:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.292 uVs 13:06:43 Integrated Voltage Measurement... 13:06:52 Voltage Offset Correction: v_off_ini = 427.141 uV, v_off_fin = 413.249 uV 13:06:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.440 uVs 13:06:52 Integrated Voltage Measurement... 13:07:01 Voltage Offset Correction: v_off_ini = 410.433 uV, v_off_fin = 422.625 uV 13:07:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.624 uVs 13:07:01 Integrated Voltage Measurement... 13:07:10 Voltage Offset Correction: v_off_ini = 430.050 uV, v_off_fin = 431.870 uV 13:07:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.161 uVs 13:07:10 Integrated Voltage Measurement... 13:07:19 Voltage Offset Correction: v_off_ini = 411.185 uV, v_off_fin = 407.087 uV 13:07:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.285 uVs 13:07:19 Integrated Voltage Measurement... 13:07:28 Voltage Offset Correction: v_off_ini = 395.565 uV, v_off_fin = 396.092 uV 13:07:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.970 uVs 13:07:32 I1X Average and RMS of Measurements VT = -85.962 +- 5.237 uVs I1X = 17.192 +- 1.047 uTm 13:07:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:07:39 Integrated Voltage Measurement... 13:07:48 Voltage Offset Correction: v_off_ini = 408.229 uV, v_off_fin = 405.039 uV 13:07:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.509 uVs 13:07:48 Integrated Voltage Measurement... 13:07:57 Voltage Offset Correction: v_off_ini = 410.751 uV, v_off_fin = 416.881 uV 13:07:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 167.084 uVs 13:07:57 Integrated Voltage Measurement... 13:08:06 Voltage Offset Correction: v_off_ini = 410.943 uV, v_off_fin = 412.262 uV 13:08:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.095 uVs 13:08:06 Integrated Voltage Measurement... 13:08:15 Voltage Offset Correction: v_off_ini = 438.266 uV, v_off_fin = 439.515 uV 13:08:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.861 uVs 13:08:15 Integrated Voltage Measurement... 13:08:24 Voltage Offset Correction: v_off_ini = 420.528 uV, v_off_fin = 413.785 uV 13:08:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.550 uVs 13:08:24 Integrated Voltage Measurement... 13:08:33 Voltage Offset Correction: v_off_ini = 427.739 uV, v_off_fin = 449.959 uV 13:08:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.231 uVs 13:08:38 I1Y Average and RMS of Measurements VT = -169.555 +- 5.878 uVs I1Y = -33.909 +- 1.174 uTm 13:08:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:45 Integrated Voltage Measurement... 13:08:54 Voltage Offset Correction: v_off_ini = 413.915 uV, v_off_fin = 398.938 uV 13:08:54 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.127 uVs 13:08:54 Integrated Voltage Measurement... 13:09:03 Voltage Offset Correction: v_off_ini = 412.770 uV, v_off_fin = 408.708 uV 13:09:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.594 uVs 13:09:03 Integrated Voltage Measurement... 13:09:12 Voltage Offset Correction: v_off_ini = 408.673 uV, v_off_fin = 422.021 uV 13:09:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.860 uVs 13:09:12 Integrated Voltage Measurement... 13:09:21 Voltage Offset Correction: v_off_ini = 416.974 uV, v_off_fin = 431.641 uV 13:09:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.812 uVs 13:09:22 Integrated Voltage Measurement... 13:09:31 Voltage Offset Correction: v_off_ini = 406.368 uV, v_off_fin = 410.167 uV 13:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.130 uVs 13:09:31 Integrated Voltage Measurement... 13:09:40 Voltage Offset Correction: v_off_ini = 428.118 uV, v_off_fin = 428.813 uV 13:09:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.086 uVs 13:09:42 I2X Average and RMS of Measurements VT = -73.268 +- 2.376 uVs I2X = 6.741 +- 0.218 uTm^2 13:09:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:09:50 Integrated Voltage Measurement... 13:09:59 Voltage Offset Correction: v_off_ini = 445.395 uV, v_off_fin = 467.781 uV 13:09:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -256.724 uVs 13:09:59 Integrated Voltage Measurement... 13:10:08 Voltage Offset Correction: v_off_ini = 423.569 uV, v_off_fin = 437.529 uV 13:10:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.120 uVs 13:10:08 Integrated Voltage Measurement... 13:10:17 Voltage Offset Correction: v_off_ini = 433.234 uV, v_off_fin = 406.326 uV 13:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.264 uVs 13:10:17 Integrated Voltage Measurement... 13:10:26 Voltage Offset Correction: v_off_ini = 412.455 uV, v_off_fin = 408.567 uV 13:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.441 uVs 13:10:26 Integrated Voltage Measurement... 13:10:35 Voltage Offset Correction: v_off_ini = 416.155 uV, v_off_fin = 409.175 uV 13:10:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.527 uVs 13:10:35 Integrated Voltage Measurement... 13:10:44 Voltage Offset Correction: v_off_ini = 408.346 uV, v_off_fin = 401.220 uV 13:10:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.378 uVs 13:10:46 I2Y Average and RMS of Measurements VT = -218.243 +- 13.009 uVs I2Y = -20.079 +- 1.197 uTm^2 13:10:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:01 Integrated Voltage Measurement... 13:11:10 Voltage Offset Correction: v_off_ini = 423.192 uV, v_off_fin = 406.875 uV 13:11:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.016 uVs 13:11:10 Integrated Voltage Measurement... 13:11:19 Voltage Offset Correction: v_off_ini = 387.105 uV, v_off_fin = 384.996 uV 13:11:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.240 uVs 13:11:19 Integrated Voltage Measurement... 13:11:28 Voltage Offset Correction: v_off_ini = 385.438 uV, v_off_fin = 376.908 uV 13:11:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.144 uVs 13:11:28 Integrated Voltage Measurement... 13:11:37 Voltage Offset Correction: v_off_ini = 389.829 uV, v_off_fin = 392.411 uV 13:11:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.117 uVs 13:11:38 Integrated Voltage Measurement... 13:11:47 Voltage Offset Correction: v_off_ini = 405.907 uV, v_off_fin = 403.536 uV 13:11:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.768 uVs 13:11:47 Integrated Voltage Measurement... 13:11:56 Voltage Offset Correction: v_off_ini = 400.343 uV, v_off_fin = 405.710 uV 13:11:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.818 uVs 13:12:00 I1X Average and RMS of Measurements VT = -101.017 +- 14.374 uVs I1X = 20.203 +- 2.875 uTm 13:12:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:07 Integrated Voltage Measurement... 13:12:16 Voltage Offset Correction: v_off_ini = 403.103 uV, v_off_fin = 392.313 uV 13:12:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.331 uVs 13:12:16 Integrated Voltage Measurement... 13:12:25 Voltage Offset Correction: v_off_ini = 397.848 uV, v_off_fin = 411.979 uV 13:12:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 168.918 uVs 13:12:25 Integrated Voltage Measurement... 13:12:34 Voltage Offset Correction: v_off_ini = 388.468 uV, v_off_fin = 391.062 uV 13:12:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.779 uVs 13:12:34 Integrated Voltage Measurement... 13:12:43 Voltage Offset Correction: v_off_ini = 389.639 uV, v_off_fin = 406.177 uV 13:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.310 uVs 13:12:43 Integrated Voltage Measurement... 13:12:52 Voltage Offset Correction: v_off_ini = 413.293 uV, v_off_fin = 403.444 uV 13:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.669 uVs 13:12:52 Integrated Voltage Measurement... 13:13:01 Voltage Offset Correction: v_off_ini = 414.252 uV, v_off_fin = 413.343 uV 13:13:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.519 uVs 13:13:05 I1Y Average and RMS of Measurements VT = -191.755 +- 5.046 uVs I1Y = -38.348 +- 1.009 uTm 13:13:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:13 Integrated Voltage Measurement... 13:13:22 Voltage Offset Correction: v_off_ini = 406.801 uV, v_off_fin = 395.001 uV 13:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.104 uVs 13:13:22 Integrated Voltage Measurement... 13:13:31 Voltage Offset Correction: v_off_ini = 414.458 uV, v_off_fin = 418.506 uV 13:13:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.710 uVs 13:13:31 Integrated Voltage Measurement... 13:13:40 Voltage Offset Correction: v_off_ini = 403.541 uV, v_off_fin = 397.165 uV 13:13:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.680 uVs 13:13:40 Integrated Voltage Measurement... 13:13:49 Voltage Offset Correction: v_off_ini = 404.017 uV, v_off_fin = 418.786 uV 13:13:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.300 uVs 13:13:49 Integrated Voltage Measurement... 13:13:58 Voltage Offset Correction: v_off_ini = 407.786 uV, v_off_fin = 411.413 uV 13:13:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.275 uVs 13:13:58 Integrated Voltage Measurement... 13:14:07 Voltage Offset Correction: v_off_ini = 421.945 uV, v_off_fin = 426.503 uV 13:14:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.788 uVs 13:14:09 I2X Average and RMS of Measurements VT = -84.310 +- 7.451 uVs I2X = 7.757 +- 0.686 uTm^2 13:14:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:17 Integrated Voltage Measurement... 13:14:26 Voltage Offset Correction: v_off_ini = 394.538 uV, v_off_fin = 407.669 uV 13:14:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -206.082 uVs 13:14:26 Integrated Voltage Measurement... 13:14:35 Voltage Offset Correction: v_off_ini = 398.191 uV, v_off_fin = 401.599 uV 13:14:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.355 uVs 13:14:35 Integrated Voltage Measurement... 13:14:44 Voltage Offset Correction: v_off_ini = 407.647 uV, v_off_fin = 414.321 uV 13:14:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.955 uVs 13:14:44 Integrated Voltage Measurement... 13:14:53 Voltage Offset Correction: v_off_ini = 415.964 uV, v_off_fin = 402.738 uV 13:14:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.051 uVs 13:14:53 Integrated Voltage Measurement... 13:15:02 Voltage Offset Correction: v_off_ini = 391.733 uV, v_off_fin = 394.447 uV 13:15:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.509 uVs 13:15:02 Integrated Voltage Measurement... 13:15:11 Voltage Offset Correction: v_off_ini = 410.526 uV, v_off_fin = 415.430 uV 13:15:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.687 uVs 13:15:14 I2Y Average and RMS of Measurements VT = -220.607 +- 3.556 uVs I2Y = -20.296 +- 0.327 uTm^2 13:15:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:29 Integrated Voltage Measurement... 13:15:38 Voltage Offset Correction: v_off_ini = 411.894 uV, v_off_fin = 394.255 uV 13:15:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.824 uVs 13:15:38 Integrated Voltage Measurement... 13:15:47 Voltage Offset Correction: v_off_ini = 397.698 uV, v_off_fin = 401.661 uV 13:15:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.322 uVs 13:15:47 Integrated Voltage Measurement... 13:15:56 Voltage Offset Correction: v_off_ini = 407.934 uV, v_off_fin = 404.271 uV 13:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.339 uVs 13:15:56 Integrated Voltage Measurement... 13:16:05 Voltage Offset Correction: v_off_ini = 421.976 uV, v_off_fin = 398.886 uV 13:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.453 uVs 13:16:05 Integrated Voltage Measurement... 13:16:14 Voltage Offset Correction: v_off_ini = 395.582 uV, v_off_fin = 394.208 uV 13:16:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.927 uVs 13:16:14 Integrated Voltage Measurement... 13:16:23 Voltage Offset Correction: v_off_ini = 397.968 uV, v_off_fin = 415.449 uV 13:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.207 uVs 13:16:27 I1X Average and RMS of Measurements VT = -99.179 +- 3.785 uVs I1X = 19.836 +- 0.757 uTm 13:16:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:34 Integrated Voltage Measurement... 13:16:43 Voltage Offset Correction: v_off_ini = 395.982 uV, v_off_fin = 385.467 uV 13:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.731 uVs 13:16:43 Integrated Voltage Measurement... 13:16:52 Voltage Offset Correction: v_off_ini = 381.480 uV, v_off_fin = 402.099 uV 13:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.340 uVs 13:16:52 Integrated Voltage Measurement... 13:17:01 Voltage Offset Correction: v_off_ini = 358.759 uV, v_off_fin = 377.354 uV 13:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.831 uVs 13:17:01 Integrated Voltage Measurement... 13:17:10 Voltage Offset Correction: v_off_ini = 412.331 uV, v_off_fin = 424.463 uV 13:17:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.521 uVs 13:17:10 Integrated Voltage Measurement... 13:17:19 Voltage Offset Correction: v_off_ini = 405.616 uV, v_off_fin = 398.846 uV 13:17:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.118 uVs 13:17:19 Integrated Voltage Measurement... 13:17:28 Voltage Offset Correction: v_off_ini = 407.902 uV, v_off_fin = 413.887 uV 13:17:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.924 uVs 13:17:32 I1Y Average and RMS of Measurements VT = -181.411 +- 2.514 uVs I1Y = -36.279 +- 0.503 uTm 13:17:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:40 Integrated Voltage Measurement... 13:17:49 Voltage Offset Correction: v_off_ini = 411.070 uV, v_off_fin = 413.165 uV 13:17:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.372 uVs 13:17:49 Integrated Voltage Measurement... 13:17:58 Voltage Offset Correction: v_off_ini = 427.619 uV, v_off_fin = 418.428 uV 13:17:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.208 uVs 13:17:58 Integrated Voltage Measurement... 13:18:07 Voltage Offset Correction: v_off_ini = 419.321 uV, v_off_fin = 391.453 uV 13:18:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.238 uVs 13:18:07 Integrated Voltage Measurement... 13:18:16 Voltage Offset Correction: v_off_ini = 413.716 uV, v_off_fin = 411.980 uV 13:18:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.758 uVs 13:18:16 Integrated Voltage Measurement... 13:18:25 Voltage Offset Correction: v_off_ini = 412.382 uV, v_off_fin = 396.145 uV 13:18:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.596 uVs 13:18:25 Integrated Voltage Measurement... 13:18:34 Voltage Offset Correction: v_off_ini = 396.242 uV, v_off_fin = 431.137 uV 13:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.191 uVs 13:18:36 I2X Average and RMS of Measurements VT = -96.561 +- 10.326 uVs I2X = 8.884 +- 0.950 uTm^2 13:18:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:18:44 Integrated Voltage Measurement... 13:18:53 Voltage Offset Correction: v_off_ini = 417.980 uV, v_off_fin = 410.869 uV 13:18:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.165 uVs 13:18:53 Integrated Voltage Measurement... 13:19:02 Voltage Offset Correction: v_off_ini = 408.978 uV, v_off_fin = 428.636 uV 13:19:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.829 uVs 13:19:02 Integrated Voltage Measurement... 13:19:11 Voltage Offset Correction: v_off_ini = 424.738 uV, v_off_fin = 425.407 uV 13:19:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.783 uVs 13:19:11 Integrated Voltage Measurement... 13:19:20 Voltage Offset Correction: v_off_ini = 426.828 uV, v_off_fin = 425.655 uV 13:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.118 uVs 13:19:20 Integrated Voltage Measurement... 13:19:29 Voltage Offset Correction: v_off_ini = 418.801 uV, v_off_fin = 420.412 uV 13:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.153 uVs 13:19:29 Integrated Voltage Measurement... 13:19:38 Voltage Offset Correction: v_off_ini = 421.534 uV, v_off_fin = 402.887 uV 13:19:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.608 uVs 13:19:41 I2Y Average and RMS of Measurements VT = -223.609 +- 3.656 uVs I2Y = -20.572 +- 0.336 uTm^2 13:19:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:56 Integrated Voltage Measurement... 13:20:05 Voltage Offset Correction: v_off_ini = 423.828 uV, v_off_fin = 442.087 uV 13:20:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -109.071 uVs 13:20:05 Integrated Voltage Measurement... 13:20:14 Voltage Offset Correction: v_off_ini = 415.475 uV, v_off_fin = 421.327 uV 13:20:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.814 uVs 13:20:14 Integrated Voltage Measurement... 13:20:23 Voltage Offset Correction: v_off_ini = 440.436 uV, v_off_fin = 436.034 uV 13:20:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.475 uVs 13:20:23 Integrated Voltage Measurement... 13:20:32 Voltage Offset Correction: v_off_ini = 425.373 uV, v_off_fin = 412.789 uV 13:20:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.984 uVs 13:20:32 Integrated Voltage Measurement... 13:20:41 Voltage Offset Correction: v_off_ini = 417.436 uV, v_off_fin = 415.293 uV 13:20:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.927 uVs 13:20:41 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = 419.334 uV, v_off_fin = 409.304 uV 13:20:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.543 uVs 13:20:54 I1X Average and RMS of Measurements VT = -108.636 +- 7.495 uVs I1X = 21.728 +- 1.498 uTm 13:20:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:01 Integrated Voltage Measurement... 13:21:10 Voltage Offset Correction: v_off_ini = 414.841 uV, v_off_fin = 408.337 uV 13:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.791 uVs 13:21:10 Integrated Voltage Measurement... 13:21:19 Voltage Offset Correction: v_off_ini = 429.341 uV, v_off_fin = 428.139 uV 13:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.950 uVs 13:21:19 Integrated Voltage Measurement... 13:21:28 Voltage Offset Correction: v_off_ini = 432.723 uV, v_off_fin = 405.273 uV 13:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.103 uVs 13:21:28 Integrated Voltage Measurement... 13:21:37 Voltage Offset Correction: v_off_ini = 422.012 uV, v_off_fin = 426.003 uV 13:21:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.780 uVs 13:21:37 Integrated Voltage Measurement... 13:21:46 Voltage Offset Correction: v_off_ini = 414.124 uV, v_off_fin = 406.961 uV 13:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.357 uVs 13:21:46 Integrated Voltage Measurement... 13:21:55 Voltage Offset Correction: v_off_ini = 426.798 uV, v_off_fin = 437.373 uV 13:21:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.391 uVs 13:21:59 I1Y Average and RMS of Measurements VT = -202.062 +- 9.427 uVs I1Y = -40.409 +- 1.885 uTm 13:22:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:22:07 Integrated Voltage Measurement... 13:22:16 Voltage Offset Correction: v_off_ini = 404.861 uV, v_off_fin = 394.571 uV 13:22:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.185 uVs 13:22:16 Integrated Voltage Measurement... 13:22:25 Voltage Offset Correction: v_off_ini = 424.991 uV, v_off_fin = 420.327 uV 13:22:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.096 uVs 13:22:25 Integrated Voltage Measurement... 13:22:34 Voltage Offset Correction: v_off_ini = 420.583 uV, v_off_fin = 408.665 uV 13:22:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.496 uVs 13:22:34 Integrated Voltage Measurement... 13:22:43 Voltage Offset Correction: v_off_ini = 395.379 uV, v_off_fin = 411.850 uV 13:22:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.193 uVs 13:22:43 Integrated Voltage Measurement... 13:22:52 Voltage Offset Correction: v_off_ini = 417.744 uV, v_off_fin = 399.259 uV 13:22:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.994 uVs 13:22:52 Integrated Voltage Measurement... 13:23:01 Voltage Offset Correction: v_off_ini = 427.480 uV, v_off_fin = 423.385 uV 13:23:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 85.699 uVs 13:23:03 I2X Average and RMS of Measurements VT = -94.277 +- 8.580 uVs I2X = 8.674 +- 0.789 uTm^2 13:23:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:23:11 Integrated Voltage Measurement... 13:23:20 Voltage Offset Correction: v_off_ini = 387.959 uV, v_off_fin = 405.746 uV 13:23:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.301 uVs 13:23:20 Integrated Voltage Measurement... 13:23:29 Voltage Offset Correction: v_off_ini = 412.744 uV, v_off_fin = 415.668 uV 13:23:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.645 uVs 13:23:29 Integrated Voltage Measurement... 13:23:38 Voltage Offset Correction: v_off_ini = 401.040 uV, v_off_fin = 415.263 uV 13:23:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.751 uVs 13:23:38 Integrated Voltage Measurement... 13:23:47 Voltage Offset Correction: v_off_ini = 421.538 uV, v_off_fin = 412.305 uV 13:23:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.852 uVs 13:23:47 Integrated Voltage Measurement... 13:23:56 Voltage Offset Correction: v_off_ini = 417.706 uV, v_off_fin = 424.798 uV 13:23:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.195 uVs 13:23:56 Integrated Voltage Measurement... 13:24:05 Voltage Offset Correction: v_off_ini = 423.189 uV, v_off_fin = 414.130 uV 13:24:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.824 uVs 13:24:08 I2Y Average and RMS of Measurements VT = -230.928 +- 8.240 uVs I2Y = -21.245 +- 0.758 uTm^2 13:24:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:22 Integrated Voltage Measurement... 13:24:31 Voltage Offset Correction: v_off_ini = 408.589 uV, v_off_fin = 396.661 uV 13:24:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -103.680 uVs 13:24:31 Integrated Voltage Measurement... 13:24:40 Voltage Offset Correction: v_off_ini = 404.301 uV, v_off_fin = 410.658 uV 13:24:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.535 uVs 13:24:40 Integrated Voltage Measurement... 13:24:49 Voltage Offset Correction: v_off_ini = 401.015 uV, v_off_fin = 392.813 uV 13:24:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.502 uVs 13:24:49 Integrated Voltage Measurement... 13:24:58 Voltage Offset Correction: v_off_ini = 410.492 uV, v_off_fin = 401.503 uV 13:24:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.059 uVs 13:24:58 Integrated Voltage Measurement... 13:25:07 Voltage Offset Correction: v_off_ini = 382.117 uV, v_off_fin = 384.501 uV 13:25:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.691 uVs 13:25:07 Integrated Voltage Measurement... 13:25:16 Voltage Offset Correction: v_off_ini = 390.383 uV, v_off_fin = 425.288 uV 13:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.761 uVs 13:25:21 I1X Average and RMS of Measurements VT = -101.872 +- 4.247 uVs I1X = 20.375 +- 0.849 uTm 13:25:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:27 Integrated Voltage Measurement... 13:25:36 Voltage Offset Correction: v_off_ini = 397.536 uV, v_off_fin = 392.100 uV 13:25:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.297 uVs 13:25:36 Integrated Voltage Measurement... 13:25:45 Voltage Offset Correction: v_off_ini = 416.820 uV, v_off_fin = 422.150 uV 13:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.235 uVs 13:25:45 Integrated Voltage Measurement... 13:25:54 Voltage Offset Correction: v_off_ini = 406.135 uV, v_off_fin = 396.682 uV 13:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.690 uVs 13:25:54 Integrated Voltage Measurement... 13:26:03 Voltage Offset Correction: v_off_ini = 405.547 uV, v_off_fin = 416.933 uV 13:26:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.588 uVs 13:26:03 Integrated Voltage Measurement... 13:26:12 Voltage Offset Correction: v_off_ini = 409.474 uV, v_off_fin = 402.829 uV 13:26:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.428 uVs 13:26:12 Integrated Voltage Measurement... 13:26:21 Voltage Offset Correction: v_off_ini = 424.767 uV, v_off_fin = 449.144 uV 13:26:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.955 uVs 13:26:26 I1Y Average and RMS of Measurements VT = -203.865 +- 3.753 uVs I1Y = -40.770 +- 0.749 uTm 13:26:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:26:33 Integrated Voltage Measurement... 13:26:42 Voltage Offset Correction: v_off_ini = 387.484 uV, v_off_fin = 407.678 uV 13:26:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -90.562 uVs 13:26:42 Integrated Voltage Measurement... 13:26:51 Voltage Offset Correction: v_off_ini = 424.985 uV, v_off_fin = 418.269 uV 13:26:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.132 uVs 13:26:51 Integrated Voltage Measurement... 13:27:00 Voltage Offset Correction: v_off_ini = 420.606 uV, v_off_fin = 397.558 uV 13:27:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.091 uVs 13:27:01 Integrated Voltage Measurement... 13:27:09 Voltage Offset Correction: v_off_ini = 424.615 uV, v_off_fin = 433.850 uV 13:27:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.000 uVs 13:27:10 Integrated Voltage Measurement... 13:27:19 Voltage Offset Correction: v_off_ini = 425.779 uV, v_off_fin = 422.936 uV 13:27:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.065 uVs 13:27:19 Integrated Voltage Measurement... 13:27:28 Voltage Offset Correction: v_off_ini = 431.017 uV, v_off_fin = 433.424 uV 13:27:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.474 uVs 13:27:30 I2X Average and RMS of Measurements VT = -99.387 +- 4.078 uVs I2X = 9.144 +- 0.375 uTm^2 13:27:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:38 Integrated Voltage Measurement... 13:27:47 Voltage Offset Correction: v_off_ini = 439.350 uV, v_off_fin = 439.689 uV 13:27:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -248.192 uVs 13:27:47 Integrated Voltage Measurement... 13:27:56 Voltage Offset Correction: v_off_ini = 447.990 uV, v_off_fin = 460.849 uV 13:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.823 uVs 13:27:56 Integrated Voltage Measurement... 13:28:05 Voltage Offset Correction: v_off_ini = 460.238 uV, v_off_fin = 440.262 uV 13:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.645 uVs 13:28:05 Integrated Voltage Measurement... 13:28:14 Voltage Offset Correction: v_off_ini = 444.455 uV, v_off_fin = 455.188 uV 13:28:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.165 uVs 13:28:14 Integrated Voltage Measurement... 13:28:23 Voltage Offset Correction: v_off_ini = 465.576 uV, v_off_fin = 459.118 uV 13:28:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.034 uVs 13:28:23 Integrated Voltage Measurement... 13:28:32 Voltage Offset Correction: v_off_ini = 443.132 uV, v_off_fin = 452.521 uV 13:28:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.060 uVs 13:28:34 I2Y Average and RMS of Measurements VT = -241.820 +- 4.585 uVs I2Y = -22.248 +- 0.422 uTm^2 13:28:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:49 Integrated Voltage Measurement... 13:28:58 Voltage Offset Correction: v_off_ini = 456.852 uV, v_off_fin = 457.409 uV 13:28:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.894 uVs 13:28:58 Integrated Voltage Measurement... 13:29:07 Voltage Offset Correction: v_off_ini = 463.239 uV, v_off_fin = 446.958 uV 13:29:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.188 uVs 13:29:07 Integrated Voltage Measurement... 13:29:16 Voltage Offset Correction: v_off_ini = 437.407 uV, v_off_fin = 444.356 uV 13:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.653 uVs 13:29:16 Integrated Voltage Measurement... 13:29:25 Voltage Offset Correction: v_off_ini = 455.298 uV, v_off_fin = 457.986 uV 13:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.899 uVs 13:29:25 Integrated Voltage Measurement... 13:29:34 Voltage Offset Correction: v_off_ini = 455.463 uV, v_off_fin = 451.489 uV 13:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.166 uVs 13:29:34 Integrated Voltage Measurement... 13:29:43 Voltage Offset Correction: v_off_ini = 453.197 uV, v_off_fin = 454.299 uV 13:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.771 uVs 13:29:48 I1X Average and RMS of Measurements VT = -109.762 +- 7.859 uVs I1X = 21.952 +- 1.572 uTm 13:29:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:29:54 Integrated Voltage Measurement... 13:30:03 Voltage Offset Correction: v_off_ini = 432.791 uV, v_off_fin = 427.717 uV 13:30:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.826 uVs 13:30:03 Integrated Voltage Measurement... 13:30:12 Voltage Offset Correction: v_off_ini = 433.320 uV, v_off_fin = 454.365 uV 13:30:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.678 uVs 13:30:12 Integrated Voltage Measurement... 13:30:21 Voltage Offset Correction: v_off_ini = 447.890 uV, v_off_fin = 435.127 uV 13:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.679 uVs 13:30:22 Integrated Voltage Measurement... 13:30:30 Voltage Offset Correction: v_off_ini = 447.391 uV, v_off_fin = 465.016 uV 13:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.157 uVs 13:30:31 Integrated Voltage Measurement... 13:30:39 Voltage Offset Correction: v_off_ini = 455.580 uV, v_off_fin = 445.584 uV 13:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.975 uVs 13:30:40 Integrated Voltage Measurement... 13:30:48 Voltage Offset Correction: v_off_ini = 455.502 uV, v_off_fin = 463.836 uV 13:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.170 uVs 13:30:53 I1Y Average and RMS of Measurements VT = -202.914 +- 3.197 uVs I1Y = -40.579 +- 0.639 uTm 13:30:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:31:00 Integrated Voltage Measurement... 13:31:09 Voltage Offset Correction: v_off_ini = 468.086 uV, v_off_fin = 468.410 uV 13:31:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.896 uVs 13:31:10 Integrated Voltage Measurement... 13:31:18 Voltage Offset Correction: v_off_ini = 475.533 uV, v_off_fin = 478.783 uV 13:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.360 uVs 13:31:19 Integrated Voltage Measurement... 13:31:28 Voltage Offset Correction: v_off_ini = 472.311 uV, v_off_fin = 456.472 uV 13:31:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.282 uVs 13:31:28 Integrated Voltage Measurement... 13:31:37 Voltage Offset Correction: v_off_ini = 462.367 uV, v_off_fin = 476.016 uV 13:31:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.059 uVs 13:31:37 Integrated Voltage Measurement... 13:31:46 Voltage Offset Correction: v_off_ini = 461.277 uV, v_off_fin = 460.239 uV 13:31:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.465 uVs 13:31:46 Integrated Voltage Measurement... 13:31:55 Voltage Offset Correction: v_off_ini = 465.232 uV, v_off_fin = 453.521 uV 13:31:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.349 uVs 13:31:57 I2X Average and RMS of Measurements VT = -111.902 +- 11.229 uVs I2X = 10.295 +- 1.033 uTm^2 13:32:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:05 Integrated Voltage Measurement... 13:32:14 Voltage Offset Correction: v_off_ini = 450.192 uV, v_off_fin = 444.831 uV 13:32:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.681 uVs 13:32:14 Integrated Voltage Measurement... 13:32:23 Voltage Offset Correction: v_off_ini = 451.838 uV, v_off_fin = 467.618 uV 13:32:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.350 uVs 13:32:23 Integrated Voltage Measurement... 13:32:32 Voltage Offset Correction: v_off_ini = 470.641 uV, v_off_fin = 478.273 uV 13:32:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.243 uVs 13:32:32 Integrated Voltage Measurement... 13:32:41 Voltage Offset Correction: v_off_ini = 502.771 uV, v_off_fin = 502.097 uV 13:32:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.991 uVs 13:32:41 Integrated Voltage Measurement... 13:32:50 Voltage Offset Correction: v_off_ini = 475.042 uV, v_off_fin = 484.677 uV 13:32:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.176 uVs 13:32:50 Integrated Voltage Measurement... 13:32:59 Voltage Offset Correction: v_off_ini = 471.237 uV, v_off_fin = 475.149 uV 13:32:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.958 uVs 13:33:01 I2Y Average and RMS of Measurements VT = -237.733 +- 3.511 uVs I2Y = -21.871 +- 0.323 uTm^2 13:33:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:16 Integrated Voltage Measurement... 13:33:25 Voltage Offset Correction: v_off_ini = 481.264 uV, v_off_fin = 475.794 uV 13:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.522 uVs 13:33:25 Integrated Voltage Measurement... 13:33:34 Voltage Offset Correction: v_off_ini = 475.516 uV, v_off_fin = 485.126 uV 13:33:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.430 uVs 13:33:34 Integrated Voltage Measurement... 13:33:43 Voltage Offset Correction: v_off_ini = 497.974 uV, v_off_fin = 480.587 uV 13:33:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.522 uVs 13:33:43 Integrated Voltage Measurement... 13:33:52 Voltage Offset Correction: v_off_ini = 481.702 uV, v_off_fin = 481.130 uV 13:33:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.285 uVs 13:33:53 Integrated Voltage Measurement... 13:34:01 Voltage Offset Correction: v_off_ini = 483.638 uV, v_off_fin = 473.757 uV 13:34:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.498 uVs 13:34:02 Integrated Voltage Measurement... 13:34:10 Voltage Offset Correction: v_off_ini = 466.935 uV, v_off_fin = 481.000 uV 13:34:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.918 uVs 13:34:15 I1X Average and RMS of Measurements VT = -116.196 +- 12.758 uVs I1X = 23.240 +- 2.552 uTm 13:34:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:22 Integrated Voltage Measurement... 13:34:30 Voltage Offset Correction: v_off_ini = 482.660 uV, v_off_fin = 457.139 uV 13:34:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.685 uVs 13:34:31 Integrated Voltage Measurement... 13:34:39 Voltage Offset Correction: v_off_ini = 478.037 uV, v_off_fin = 495.381 uV 13:34:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.676 uVs 13:34:40 Integrated Voltage Measurement... 13:34:48 Voltage Offset Correction: v_off_ini = 478.482 uV, v_off_fin = 471.122 uV 13:34:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.474 uVs 13:34:49 Integrated Voltage Measurement... 13:34:58 Voltage Offset Correction: v_off_ini = 467.117 uV, v_off_fin = 495.182 uV 13:34:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.844 uVs 13:34:58 Integrated Voltage Measurement... 13:35:07 Voltage Offset Correction: v_off_ini = 495.051 uV, v_off_fin = 495.515 uV 13:35:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.662 uVs 13:35:07 Integrated Voltage Measurement... 13:35:16 Voltage Offset Correction: v_off_ini = 495.650 uV, v_off_fin = 509.037 uV 13:35:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.493 uVs 13:35:20 I1Y Average and RMS of Measurements VT = -207.472 +- 2.436 uVs I1Y = -41.490 +- 0.487 uTm 13:35:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:28 Integrated Voltage Measurement... 13:35:37 Voltage Offset Correction: v_off_ini = 498.205 uV, v_off_fin = 476.588 uV 13:35:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -135.665 uVs 13:35:37 Integrated Voltage Measurement... 13:35:46 Voltage Offset Correction: v_off_ini = 485.025 uV, v_off_fin = 492.628 uV 13:35:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.367 uVs 13:35:46 Integrated Voltage Measurement... 13:35:55 Voltage Offset Correction: v_off_ini = 462.720 uV, v_off_fin = 462.234 uV 13:35:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.413 uVs 13:35:55 Integrated Voltage Measurement... 13:36:04 Voltage Offset Correction: v_off_ini = 485.324 uV, v_off_fin = 476.598 uV 13:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.170 uVs 13:36:04 Integrated Voltage Measurement... 13:36:13 Voltage Offset Correction: v_off_ini = 485.128 uV, v_off_fin = 470.410 uV 13:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.999 uVs 13:36:13 Integrated Voltage Measurement... 13:36:22 Voltage Offset Correction: v_off_ini = 486.424 uV, v_off_fin = 484.470 uV 13:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.228 uVs 13:36:24 I2X Average and RMS of Measurements VT = -112.973 +- 6.464 uVs I2X = 10.393 +- 0.594 uTm^2 13:36:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:32 Integrated Voltage Measurement... 13:36:41 Voltage Offset Correction: v_off_ini = 479.946 uV, v_off_fin = 487.256 uV 13:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.355 uVs 13:36:41 Integrated Voltage Measurement... 13:36:50 Voltage Offset Correction: v_off_ini = 472.163 uV, v_off_fin = 461.802 uV 13:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.148 uVs 13:36:50 Integrated Voltage Measurement... 13:36:59 Voltage Offset Correction: v_off_ini = 471.520 uV, v_off_fin = 450.498 uV 13:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.754 uVs 13:36:59 Integrated Voltage Measurement... 13:37:08 Voltage Offset Correction: v_off_ini = 461.373 uV, v_off_fin = 470.590 uV 13:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.318 uVs 13:37:08 Integrated Voltage Measurement... 13:37:17 Voltage Offset Correction: v_off_ini = 474.207 uV, v_off_fin = 463.760 uV 13:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.648 uVs 13:37:17 Integrated Voltage Measurement... 13:37:26 Voltage Offset Correction: v_off_ini = 469.025 uV, v_off_fin = 466.676 uV 13:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.970 uVs 13:37:29 I2Y Average and RMS of Measurements VT = -242.032 +- 3.468 uVs I2Y = -22.267 +- 0.319 uTm^2 13:37:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:44 Integrated Voltage Measurement... 13:37:53 Voltage Offset Correction: v_off_ini = 465.188 uV, v_off_fin = 456.892 uV 13:37:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.358 uVs 13:37:53 Integrated Voltage Measurement... 13:38:02 Voltage Offset Correction: v_off_ini = 477.574 uV, v_off_fin = 452.660 uV 13:38:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.503 uVs 13:38:02 Integrated Voltage Measurement... 13:38:11 Voltage Offset Correction: v_off_ini = 450.189 uV, v_off_fin = 456.457 uV 13:38:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.936 uVs 13:38:11 Integrated Voltage Measurement... 13:38:20 Voltage Offset Correction: v_off_ini = 475.318 uV, v_off_fin = 484.358 uV 13:38:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.611 uVs 13:38:20 Integrated Voltage Measurement... 13:38:29 Voltage Offset Correction: v_off_ini = 479.531 uV, v_off_fin = 464.905 uV 13:38:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.661 uVs 13:38:29 Integrated Voltage Measurement... 13:38:38 Voltage Offset Correction: v_off_ini = 473.359 uV, v_off_fin = 483.243 uV 13:38:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.466 uVs 13:38:42 I1X Average and RMS of Measurements VT = -116.089 +- 3.030 uVs I1X = 23.218 +- 0.606 uTm 13:38:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:49 Integrated Voltage Measurement... 13:38:58 Voltage Offset Correction: v_off_ini = 453.323 uV, v_off_fin = 458.184 uV 13:38:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.077 uVs 13:38:58 Integrated Voltage Measurement... 13:39:07 Voltage Offset Correction: v_off_ini = 471.378 uV, v_off_fin = 487.243 uV 13:39:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.450 uVs 13:39:07 Integrated Voltage Measurement... 13:39:16 Voltage Offset Correction: v_off_ini = 490.608 uV, v_off_fin = 483.590 uV 13:39:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.466 uVs 13:39:16 Integrated Voltage Measurement... 13:39:25 Voltage Offset Correction: v_off_ini = 475.858 uV, v_off_fin = 485.960 uV 13:39:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 238.713 uVs 13:39:25 Integrated Voltage Measurement... 13:39:34 Voltage Offset Correction: v_off_ini = 488.845 uV, v_off_fin = 469.725 uV 13:39:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.407 uVs 13:39:34 Integrated Voltage Measurement... 13:39:43 Voltage Offset Correction: v_off_ini = 463.484 uV, v_off_fin = 487.409 uV 13:39:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 232.568 uVs 13:39:47 I1Y Average and RMS of Measurements VT = -215.114 +- 9.094 uVs I1Y = -43.018 +- 1.819 uTm 13:39:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:55 Integrated Voltage Measurement... 13:40:04 Voltage Offset Correction: v_off_ini = 469.894 uV, v_off_fin = 454.995 uV 13:40:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.840 uVs 13:40:04 Integrated Voltage Measurement... 13:40:13 Voltage Offset Correction: v_off_ini = 473.063 uV, v_off_fin = 483.475 uV 13:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.585 uVs 13:40:13 Integrated Voltage Measurement... 13:40:22 Voltage Offset Correction: v_off_ini = 448.010 uV, v_off_fin = 448.477 uV 13:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.642 uVs 13:40:22 Integrated Voltage Measurement... 13:40:31 Voltage Offset Correction: v_off_ini = 461.091 uV, v_off_fin = 483.366 uV 13:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.668 uVs 13:40:31 Integrated Voltage Measurement... 13:40:40 Voltage Offset Correction: v_off_ini = 459.207 uV, v_off_fin = 440.389 uV 13:40:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.710 uVs 13:40:40 Integrated Voltage Measurement... 13:40:49 Voltage Offset Correction: v_off_ini = 480.779 uV, v_off_fin = 484.042 uV 13:40:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.514 uVs 13:40:51 I2X Average and RMS of Measurements VT = -119.327 +- 15.984 uVs I2X = 10.978 +- 1.471 uTm^2 13:40:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:40:59 Integrated Voltage Measurement... 13:41:08 Voltage Offset Correction: v_off_ini = 461.800 uV, v_off_fin = 458.260 uV 13:41:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.868 uVs 13:41:08 Integrated Voltage Measurement... 13:41:17 Voltage Offset Correction: v_off_ini = 457.467 uV, v_off_fin = 450.984 uV 13:41:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.654 uVs 13:41:17 Integrated Voltage Measurement... 13:41:26 Voltage Offset Correction: v_off_ini = 457.924 uV, v_off_fin = 452.845 uV 13:41:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.563 uVs 13:41:26 Integrated Voltage Measurement... 13:41:35 Voltage Offset Correction: v_off_ini = 453.501 uV, v_off_fin = 473.486 uV 13:41:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.811 uVs 13:41:35 Integrated Voltage Measurement... 13:41:44 Voltage Offset Correction: v_off_ini = 460.212 uV, v_off_fin = 465.382 uV 13:41:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.392 uVs 13:41:44 Integrated Voltage Measurement... 13:41:53 Voltage Offset Correction: v_off_ini = 451.150 uV, v_off_fin = 440.319 uV 13:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.265 uVs 13:41:56 I2Y Average and RMS of Measurements VT = -238.925 +- 3.066 uVs I2Y = -21.981 +- 0.282 uTm^2 13:42:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:12 Integrated Voltage Measurement... 13:42:21 Voltage Offset Correction: v_off_ini = 467.678 uV, v_off_fin = 437.353 uV 13:42:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.014 uVs 13:42:21 Integrated Voltage Measurement... 13:42:30 Voltage Offset Correction: v_off_ini = 452.445 uV, v_off_fin = 452.721 uV 13:42:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.844 uVs 13:42:30 Integrated Voltage Measurement... 13:42:39 Voltage Offset Correction: v_off_ini = 450.093 uV, v_off_fin = 454.301 uV 13:42:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.538 uVs 13:42:39 Integrated Voltage Measurement... 13:42:48 Voltage Offset Correction: v_off_ini = 456.562 uV, v_off_fin = 462.849 uV 13:42:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.817 uVs 13:42:48 Integrated Voltage Measurement... 13:42:57 Voltage Offset Correction: v_off_ini = 453.051 uV, v_off_fin = 439.367 uV 13:42:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.902 uVs 13:42:57 Integrated Voltage Measurement... 13:43:06 Voltage Offset Correction: v_off_ini = 459.632 uV, v_off_fin = 453.240 uV 13:43:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.293 uVs 13:43:10 I1X Average and RMS of Measurements VT = -130.568 +- 10.651 uVs I1X = 26.114 +- 2.130 uTm 13:43:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:17 Integrated Voltage Measurement... 13:43:26 Voltage Offset Correction: v_off_ini = 450.273 uV, v_off_fin = 448.348 uV 13:43:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.150 uVs 13:43:26 Integrated Voltage Measurement... 13:43:35 Voltage Offset Correction: v_off_ini = 458.520 uV, v_off_fin = 467.398 uV 13:43:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.416 uVs 13:43:35 Integrated Voltage Measurement... 13:43:44 Voltage Offset Correction: v_off_ini = 448.254 uV, v_off_fin = 433.986 uV 13:43:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.760 uVs 13:43:44 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = 457.213 uV, v_off_fin = 458.117 uV 13:43:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.835 uVs 13:43:53 Integrated Voltage Measurement... 13:44:02 Voltage Offset Correction: v_off_ini = 466.109 uV, v_off_fin = 444.268 uV 13:44:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.541 uVs 13:44:02 Integrated Voltage Measurement... 13:44:11 Voltage Offset Correction: v_off_ini = 444.509 uV, v_off_fin = 470.032 uV 13:44:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.828 uVs 13:44:15 I1Y Average and RMS of Measurements VT = -210.755 +- 0.417 uVs I1Y = -42.147 +- 0.083 uTm 13:44:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:23 Integrated Voltage Measurement... 13:44:32 Voltage Offset Correction: v_off_ini = 443.849 uV, v_off_fin = 429.740 uV 13:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.381 uVs 13:44:32 Integrated Voltage Measurement... 13:44:41 Voltage Offset Correction: v_off_ini = 445.303 uV, v_off_fin = 428.692 uV 13:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.608 uVs 13:44:41 Integrated Voltage Measurement... 13:44:50 Voltage Offset Correction: v_off_ini = 443.212 uV, v_off_fin = 434.902 uV 13:44:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.270 uVs 13:44:50 Integrated Voltage Measurement... 13:44:59 Voltage Offset Correction: v_off_ini = 442.697 uV, v_off_fin = 470.259 uV 13:44:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.653 uVs 13:44:59 Integrated Voltage Measurement... 13:45:08 Voltage Offset Correction: v_off_ini = 434.831 uV, v_off_fin = 440.237 uV 13:45:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.130 uVs 13:45:08 Integrated Voltage Measurement... 13:45:17 Voltage Offset Correction: v_off_ini = 450.165 uV, v_off_fin = 468.745 uV 13:45:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.619 uVs 13:45:19 I2X Average and RMS of Measurements VT = -121.944 +- 5.067 uVs I2X = 11.219 +- 0.466 uTm^2 13:45:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:27 Integrated Voltage Measurement... 13:45:36 Voltage Offset Correction: v_off_ini = 461.477 uV, v_off_fin = 445.380 uV 13:45:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -233.238 uVs 13:45:36 Integrated Voltage Measurement... 13:45:45 Voltage Offset Correction: v_off_ini = 449.914 uV, v_off_fin = 446.297 uV 13:45:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.851 uVs 13:45:45 Integrated Voltage Measurement... 13:45:54 Voltage Offset Correction: v_off_ini = 443.057 uV, v_off_fin = 442.933 uV 13:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.267 uVs 13:45:54 Integrated Voltage Measurement... 13:46:03 Voltage Offset Correction: v_off_ini = 439.253 uV, v_off_fin = 444.200 uV 13:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.313 uVs 13:46:03 Integrated Voltage Measurement... 13:46:12 Voltage Offset Correction: v_off_ini = 434.909 uV, v_off_fin = 456.460 uV 13:46:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = -0.0001 mm dXY = 1.0000 mm VT = -245.176 uVs 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = 455.692 uV, v_off_fin = 451.003 uV 13:46:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = -0.0001 mm dXY = -1.0000 mm VT = 246.354 uVs 13:46:24 I2Y Average and RMS of Measurements VT = -244.533 +- 5.679 uVs I2Y = -22.497 +- 0.522 uTm^2 13:46:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:40 Integrated Voltage Measurement... 13:46:49 Voltage Offset Correction: v_off_ini = 460.204 uV, v_off_fin = 440.176 uV 13:46:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.251 uVs 13:46:49 Integrated Voltage Measurement... 13:46:58 Voltage Offset Correction: v_off_ini = 454.034 uV, v_off_fin = 445.156 uV 13:46:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.588 uVs 13:46:58 Integrated Voltage Measurement... 13:47:07 Voltage Offset Correction: v_off_ini = 456.938 uV, v_off_fin = 446.312 uV 13:47:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.805 uVs 13:47:07 Integrated Voltage Measurement... 13:47:16 Voltage Offset Correction: v_off_ini = 447.277 uV, v_off_fin = 441.866 uV 13:47:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.165 uVs 13:47:16 Integrated Voltage Measurement... 13:47:25 Voltage Offset Correction: v_off_ini = 448.267 uV, v_off_fin = 446.834 uV 13:47:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.253 uVs 13:47:25 Integrated Voltage Measurement... 13:47:34 Voltage Offset Correction: v_off_ini = 467.360 uV, v_off_fin = 465.365 uV 13:47:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.216 uVs 13:47:38 I1X Average and RMS of Measurements VT = -124.879 +- 2.466 uVs I1X = 24.977 +- 0.493 uTm 13:47:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:45 Integrated Voltage Measurement... 13:47:54 Voltage Offset Correction: v_off_ini = 437.829 uV, v_off_fin = 439.504 uV 13:47:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.162 uVs 13:47:54 Integrated Voltage Measurement... 13:48:03 Voltage Offset Correction: v_off_ini = 444.686 uV, v_off_fin = 463.505 uV 13:48:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.388 uVs 13:48:03 Integrated Voltage Measurement... 13:48:12 Voltage Offset Correction: v_off_ini = 458.893 uV, v_off_fin = 442.605 uV 13:48:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.418 uVs 13:48:12 Integrated Voltage Measurement... 13:48:21 Voltage Offset Correction: v_off_ini = 439.892 uV, v_off_fin = 441.479 uV 13:48:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 221.387 uVs 13:48:21 Integrated Voltage Measurement... 13:48:30 Voltage Offset Correction: v_off_ini = 445.019 uV, v_off_fin = 443.690 uV 13:48:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.249 uVs 13:48:30 Integrated Voltage Measurement... 13:48:39 Voltage Offset Correction: v_off_ini = 471.202 uV, v_off_fin = 464.270 uV 13:48:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.013 uVs 13:48:43 I1Y Average and RMS of Measurements VT = -213.269 +- 6.007 uVs I1Y = -42.650 +- 1.201 uTm 13:48:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:51 Integrated Voltage Measurement... 13:49:00 Voltage Offset Correction: v_off_ini = 426.692 uV, v_off_fin = 428.498 uV 13:49:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -91.994 uVs 13:49:00 Integrated Voltage Measurement... 13:49:09 Voltage Offset Correction: v_off_ini = 445.691 uV, v_off_fin = 452.574 uV 13:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.438 uVs 13:49:09 Integrated Voltage Measurement... 13:49:18 Voltage Offset Correction: v_off_ini = 442.352 uV, v_off_fin = 428.434 uV 13:49:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.609 uVs 13:49:18 Integrated Voltage Measurement... 13:49:27 Voltage Offset Correction: v_off_ini = 440.475 uV, v_off_fin = 450.724 uV 13:49:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.120 uVs 13:49:27 Integrated Voltage Measurement... 13:49:36 Voltage Offset Correction: v_off_ini = 442.315 uV, v_off_fin = 432.155 uV 13:49:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.227 uVs 13:49:36 Integrated Voltage Measurement... 13:49:45 Voltage Offset Correction: v_off_ini = 437.952 uV, v_off_fin = 448.250 uV 13:49:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 137.242 uVs 13:49:48 I2X Average and RMS of Measurements VT = -118.772 +- 8.342 uVs I2X = 10.927 +- 0.768 uTm^2 13:49:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:55 Integrated Voltage Measurement... 13:50:04 Voltage Offset Correction: v_off_ini = 450.209 uV, v_off_fin = 426.921 uV 13:50:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.862 uVs 13:50:04 Integrated Voltage Measurement... 13:50:13 Voltage Offset Correction: v_off_ini = 437.032 uV, v_off_fin = 443.977 uV 13:50:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.458 uVs 13:50:13 Integrated Voltage Measurement... 13:50:22 Voltage Offset Correction: v_off_ini = 443.936 uV, v_off_fin = 458.163 uV 13:50:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.931 uVs 13:50:22 Integrated Voltage Measurement... 13:50:31 Voltage Offset Correction: v_off_ini = 436.051 uV, v_off_fin = 437.868 uV 13:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.277 uVs 13:50:32 Integrated Voltage Measurement... 13:50:41 Voltage Offset Correction: v_off_ini = 447.642 uV, v_off_fin = 438.167 uV 13:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.196 uVs 13:50:41 Integrated Voltage Measurement... 13:50:50 Voltage Offset Correction: v_off_ini = 443.818 uV, v_off_fin = 433.113 uV 13:50:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.040 uVs 13:50:52 I2Y Average and RMS of Measurements VT = -252.627 +- 6.099 uVs I2Y = -23.242 +- 0.561 uTm^2 13:51:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:10 Integrated Voltage Measurement... 13:51:19 Voltage Offset Correction: v_off_ini = 445.022 uV, v_off_fin = 433.648 uV 13:51:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.189 uVs 13:51:19 Integrated Voltage Measurement... 13:51:28 Voltage Offset Correction: v_off_ini = 444.319 uV, v_off_fin = 448.410 uV 13:51:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.127 uVs 13:51:28 Integrated Voltage Measurement... 13:51:37 Voltage Offset Correction: v_off_ini = 451.670 uV, v_off_fin = 431.116 uV 13:51:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.741 uVs 13:51:37 Integrated Voltage Measurement... 13:51:46 Voltage Offset Correction: v_off_ini = 460.299 uV, v_off_fin = 454.596 uV 13:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.891 uVs 13:51:46 Integrated Voltage Measurement... 13:51:55 Voltage Offset Correction: v_off_ini = 427.469 uV, v_off_fin = 450.651 uV 13:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.135 uVs 13:51:55 Integrated Voltage Measurement... 13:52:04 Voltage Offset Correction: v_off_ini = 433.567 uV, v_off_fin = 446.569 uV 13:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.573 uVs 13:52:09 I1X Average and RMS of Measurements VT = -129.443 +- 9.264 uVs I1X = 25.889 +- 1.853 uTm 13:52:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:16 Integrated Voltage Measurement... 13:52:24 Voltage Offset Correction: v_off_ini = 448.080 uV, v_off_fin = 428.934 uV 13:52:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.655 uVs 13:52:25 Integrated Voltage Measurement... 13:52:33 Voltage Offset Correction: v_off_ini = 443.721 uV, v_off_fin = 449.740 uV 13:52:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.243 uVs 13:52:34 Integrated Voltage Measurement... 13:52:43 Voltage Offset Correction: v_off_ini = 446.521 uV, v_off_fin = 436.393 uV 13:52:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.108 uVs 13:52:43 Integrated Voltage Measurement... 13:52:52 Voltage Offset Correction: v_off_ini = 449.875 uV, v_off_fin = 458.172 uV 13:52:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.469 uVs 13:52:52 Integrated Voltage Measurement... 13:53:01 Voltage Offset Correction: v_off_ini = 444.187 uV, v_off_fin = 432.678 uV 13:53:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.471 uVs 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = 449.959 uV, v_off_fin = 451.598 uV 13:53:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.308 uVs 13:53:14 I1Y Average and RMS of Measurements VT = -213.876 +- 3.653 uVs I1Y = -42.773 +- 0.732 uTm 13:53:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:22 Integrated Voltage Measurement... 13:53:31 Voltage Offset Correction: v_off_ini = 449.335 uV, v_off_fin = 442.482 uV 13:53:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.192 uVs 13:53:31 Integrated Voltage Measurement... 13:53:40 Voltage Offset Correction: v_off_ini = 453.763 uV, v_off_fin = 473.210 uV 13:53:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.525 uVs 13:53:40 Integrated Voltage Measurement... 13:53:49 Voltage Offset Correction: v_off_ini = 458.253 uV, v_off_fin = 449.261 uV 13:53:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -120.410 uVs 13:53:49 Integrated Voltage Measurement... 13:53:58 Voltage Offset Correction: v_off_ini = 460.811 uV, v_off_fin = 463.465 uV 13:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.023 uVs 13:53:58 Integrated Voltage Measurement... 13:54:07 Voltage Offset Correction: v_off_ini = 454.689 uV, v_off_fin = 434.514 uV 13:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.310 uVs 13:54:07 Integrated Voltage Measurement... 13:54:16 Voltage Offset Correction: v_off_ini = 453.319 uV, v_off_fin = 447.611 uV 13:54:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.959 uVs 13:54:18 I2X Average and RMS of Measurements VT = -128.070 +- 10.548 uVs I2X = 11.783 +- 0.970 uTm^2 13:54:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:26 Integrated Voltage Measurement... 13:54:35 Voltage Offset Correction: v_off_ini = 450.440 uV, v_off_fin = 444.513 uV 13:54:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.592 uVs 13:54:35 Integrated Voltage Measurement... 13:54:44 Voltage Offset Correction: v_off_ini = 443.181 uV, v_off_fin = 436.801 uV 13:54:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.457 uVs 13:54:44 Integrated Voltage Measurement... 13:54:53 Voltage Offset Correction: v_off_ini = 428.559 uV, v_off_fin = 428.306 uV 13:54:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.995 uVs 13:54:53 Integrated Voltage Measurement... 13:55:02 Voltage Offset Correction: v_off_ini = 434.936 uV, v_off_fin = 420.932 uV 13:55:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.398 uVs 13:55:02 Integrated Voltage Measurement... 13:55:11 Voltage Offset Correction: v_off_ini = 419.181 uV, v_off_fin = 424.554 uV 13:55:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.490 uVs 13:55:11 Integrated Voltage Measurement... 13:55:20 Voltage Offset Correction: v_off_ini = 420.206 uV, v_off_fin = 427.971 uV 13:55:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.775 uVs 13:55:23 I2Y Average and RMS of Measurements VT = -241.951 +- 8.595 uVs I2Y = -22.259 +- 0.791 uTm^2 13:55:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:41 Integrated Voltage Measurement... 13:55:50 Voltage Offset Correction: v_off_ini = 445.763 uV, v_off_fin = 422.156 uV 13:55:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.048 uVs 13:55:50 Integrated Voltage Measurement... 13:55:59 Voltage Offset Correction: v_off_ini = 416.263 uV, v_off_fin = 427.431 uV 13:55:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.424 uVs 13:55:59 Integrated Voltage Measurement... 13:56:08 Voltage Offset Correction: v_off_ini = 418.896 uV, v_off_fin = 429.428 uV 13:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.513 uVs 13:56:08 Integrated Voltage Measurement... 13:56:17 Voltage Offset Correction: v_off_ini = 430.379 uV, v_off_fin = 427.088 uV 13:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.507 uVs 13:56:17 Integrated Voltage Measurement... 13:56:26 Voltage Offset Correction: v_off_ini = 427.355 uV, v_off_fin = 414.534 uV 13:56:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.839 uVs 13:56:26 Integrated Voltage Measurement... 13:56:35 Voltage Offset Correction: v_off_ini = 415.469 uV, v_off_fin = 418.916 uV 13:56:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.969 uVs 13:56:39 I1X Average and RMS of Measurements VT = -122.050 +- 9.437 uVs I1X = 24.410 +- 1.887 uTm 13:56:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:46 Integrated Voltage Measurement... 13:56:55 Voltage Offset Correction: v_off_ini = 421.741 uV, v_off_fin = 411.617 uV 13:56:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.905 uVs 13:56:55 Integrated Voltage Measurement... 13:57:04 Voltage Offset Correction: v_off_ini = 417.011 uV, v_off_fin = 424.715 uV 13:57:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.105 uVs 13:57:04 Integrated Voltage Measurement... 13:57:13 Voltage Offset Correction: v_off_ini = 413.385 uV, v_off_fin = 415.700 uV 13:57:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.454 uVs 13:57:13 Integrated Voltage Measurement... 13:57:22 Voltage Offset Correction: v_off_ini = 404.632 uV, v_off_fin = 413.298 uV 13:57:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.180 uVs 13:57:22 Integrated Voltage Measurement... 13:57:31 Voltage Offset Correction: v_off_ini = 407.447 uV, v_off_fin = 424.489 uV 13:57:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.156 uVs 13:57:31 Integrated Voltage Measurement... 13:57:40 Voltage Offset Correction: v_off_ini = 447.794 uV, v_off_fin = 429.313 uV 13:57:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.700 uVs 13:57:44 I1Y Average and RMS of Measurements VT = -201.917 +- 0.485 uVs I1Y = -40.383 +- 0.095 uTm 13:57:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:52 Integrated Voltage Measurement... 13:58:01 Voltage Offset Correction: v_off_ini = 413.629 uV, v_off_fin = 398.019 uV 13:58:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.800 uVs 13:58:01 Integrated Voltage Measurement... 13:58:10 Voltage Offset Correction: v_off_ini = 415.866 uV, v_off_fin = 417.253 uV 13:58:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.532 uVs 13:58:10 Integrated Voltage Measurement... 13:58:19 Voltage Offset Correction: v_off_ini = 414.639 uV, v_off_fin = 404.017 uV 13:58:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.801 uVs 13:58:19 Integrated Voltage Measurement... 13:58:28 Voltage Offset Correction: v_off_ini = 417.298 uV, v_off_fin = 427.053 uV 13:58:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.615 uVs 13:58:28 Integrated Voltage Measurement... 13:58:37 Voltage Offset Correction: v_off_ini = 410.673 uV, v_off_fin = 396.642 uV 13:58:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.363 uVs 13:58:37 Integrated Voltage Measurement... 13:58:46 Voltage Offset Correction: v_off_ini = 399.133 uV, v_off_fin = 412.304 uV 13:58:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.946 uVs 13:58:48 I2X Average and RMS of Measurements VT = -102.343 +- 5.565 uVs I2X = 9.415 +- 0.512 uTm^2 13:58:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:56 Integrated Voltage Measurement... 13:59:05 Voltage Offset Correction: v_off_ini = 396.584 uV, v_off_fin = 412.705 uV 13:59:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.262 uVs 13:59:05 Integrated Voltage Measurement... 13:59:14 Voltage Offset Correction: v_off_ini = 413.238 uV, v_off_fin = 410.073 uV 13:59:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.551 uVs 13:59:14 Integrated Voltage Measurement... 13:59:23 Voltage Offset Correction: v_off_ini = 385.278 uV, v_off_fin = 377.694 uV 13:59:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.223 uVs 13:59:23 Integrated Voltage Measurement... 13:59:32 Voltage Offset Correction: v_off_ini = 414.117 uV, v_off_fin = 410.001 uV 13:59:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.698 uVs 13:59:32 Integrated Voltage Measurement... 13:59:41 Voltage Offset Correction: v_off_ini = 407.049 uV, v_off_fin = 404.817 uV 13:59:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.677 uVs 13:59:41 Integrated Voltage Measurement... 13:59:50 Voltage Offset Correction: v_off_ini = 412.123 uV, v_off_fin = 420.637 uV 13:59:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.344 uVs 13:59:53 I2Y Average and RMS of Measurements VT = -214.293 +- 4.379 uVs I2Y = -19.715 +- 0.403 uTm^2 14:00:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:11 Integrated Voltage Measurement... 14:00:20 Voltage Offset Correction: v_off_ini = 412.955 uV, v_off_fin = 387.875 uV 14:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.315 uVs 14:00:20 Integrated Voltage Measurement... 14:00:29 Voltage Offset Correction: v_off_ini = 385.558 uV, v_off_fin = 400.141 uV 14:00:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.984 uVs 14:00:29 Integrated Voltage Measurement... 14:00:38 Voltage Offset Correction: v_off_ini = 396.900 uV, v_off_fin = 398.168 uV 14:00:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.075 uVs 14:00:38 Integrated Voltage Measurement... 14:00:47 Voltage Offset Correction: v_off_ini = 399.538 uV, v_off_fin = 409.314 uV 14:00:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.380 uVs 14:00:47 Integrated Voltage Measurement... 14:00:56 Voltage Offset Correction: v_off_ini = 409.356 uV, v_off_fin = 408.228 uV 14:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.242 uVs 14:00:56 Integrated Voltage Measurement... 14:01:05 Voltage Offset Correction: v_off_ini = 415.670 uV, v_off_fin = 411.676 uV 14:01:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.324 uVs 14:01:10 I1X Average and RMS of Measurements VT = -107.720 +- 5.253 uVs I1X = 21.545 +- 1.051 uTm 14:01:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:16 Integrated Voltage Measurement... 14:01:25 Voltage Offset Correction: v_off_ini = 415.034 uV, v_off_fin = 404.030 uV 14:01:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.864 uVs 14:01:25 Integrated Voltage Measurement... 14:01:34 Voltage Offset Correction: v_off_ini = 426.056 uV, v_off_fin = 431.998 uV 14:01:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.314 uVs 14:01:34 Integrated Voltage Measurement... 14:01:43 Voltage Offset Correction: v_off_ini = 419.642 uV, v_off_fin = 408.303 uV 14:01:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.607 uVs 14:01:43 Integrated Voltage Measurement... 14:01:52 Voltage Offset Correction: v_off_ini = 404.228 uV, v_off_fin = 420.633 uV 14:01:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.807 uVs 14:01:52 Integrated Voltage Measurement... 14:02:01 Voltage Offset Correction: v_off_ini = 410.080 uV, v_off_fin = 394.526 uV 14:02:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.237 uVs 14:02:01 Integrated Voltage Measurement... 14:02:10 Voltage Offset Correction: v_off_ini = 401.502 uV, v_off_fin = 421.644 uV 14:02:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.339 uVs 14:02:15 I1Y Average and RMS of Measurements VT = -195.028 +- 5.140 uVs I1Y = -39.006 +- 1.028 uTm 14:02:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = 403.695 uV, v_off_fin = 397.351 uV 14:02:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.342 uVs 14:02:31 Integrated Voltage Measurement... 14:02:40 Voltage Offset Correction: v_off_ini = 399.119 uV, v_off_fin = 416.434 uV 14:02:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.942 uVs 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = 389.773 uV, v_off_fin = 390.465 uV 14:02:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.621 uVs 14:02:49 Integrated Voltage Measurement... 14:02:58 Voltage Offset Correction: v_off_ini = 384.836 uV, v_off_fin = 396.654 uV 14:02:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.217 uVs 14:02:58 Integrated Voltage Measurement... 14:03:07 Voltage Offset Correction: v_off_ini = 397.313 uV, v_off_fin = 389.275 uV 14:03:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.343 uVs 14:03:08 Integrated Voltage Measurement... 14:03:16 Voltage Offset Correction: v_off_ini = 395.177 uV, v_off_fin = 395.649 uV 14:03:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.252 uVs 14:03:19 I2X Average and RMS of Measurements VT = -100.119 +- 3.993 uVs I2X = 9.211 +- 0.367 uTm^2 14:03:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:27 Integrated Voltage Measurement... 14:03:36 Voltage Offset Correction: v_off_ini = 403.039 uV, v_off_fin = 410.443 uV 14:03:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.668 uVs 14:03:36 Integrated Voltage Measurement... 14:03:45 Voltage Offset Correction: v_off_ini = 418.744 uV, v_off_fin = 413.347 uV 14:03:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.204 uVs 14:03:45 Integrated Voltage Measurement... 14:03:54 Voltage Offset Correction: v_off_ini = 417.279 uV, v_off_fin = 405.433 uV 14:03:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.071 uVs 14:03:54 Integrated Voltage Measurement... 14:04:03 Voltage Offset Correction: v_off_ini = 411.757 uV, v_off_fin = 408.677 uV 14:04:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.089 uVs 14:04:03 Integrated Voltage Measurement... 14:04:12 Voltage Offset Correction: v_off_ini = 423.469 uV, v_off_fin = 421.721 uV 14:04:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.515 uVs 14:04:12 Integrated Voltage Measurement... 14:04:21 Voltage Offset Correction: v_off_ini = 438.920 uV, v_off_fin = 419.097 uV 14:04:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.981 uVs 14:04:23 I2Y Average and RMS of Measurements VT = -206.421 +- 7.817 uVs I2Y = -18.991 +- 0.719 uTm^2 14:04:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:42 Integrated Voltage Measurement... 14:04:51 Voltage Offset Correction: v_off_ini = 418.149 uV, v_off_fin = 417.187 uV 14:04:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -103.159 uVs 14:04:51 Integrated Voltage Measurement... 14:05:00 Voltage Offset Correction: v_off_ini = 438.994 uV, v_off_fin = 437.376 uV 14:05:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.839 uVs 14:05:00 Integrated Voltage Measurement... 14:05:09 Voltage Offset Correction: v_off_ini = 429.707 uV, v_off_fin = 426.823 uV 14:05:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.860 uVs 14:05:09 Integrated Voltage Measurement... 14:05:18 Voltage Offset Correction: v_off_ini = 427.375 uV, v_off_fin = 443.083 uV 14:05:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.328 uVs 14:05:18 Integrated Voltage Measurement... 14:05:27 Voltage Offset Correction: v_off_ini = 432.882 uV, v_off_fin = 437.918 uV 14:05:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.269 uVs 14:05:27 Integrated Voltage Measurement... 14:05:36 Voltage Offset Correction: v_off_ini = 442.771 uV, v_off_fin = 433.720 uV 14:05:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.756 uVs 14:05:40 I1X Average and RMS of Measurements VT = -92.368 +- 3.529 uVs I1X = 18.475 +- 0.706 uTm 14:05:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:47 Integrated Voltage Measurement... 14:05:56 Voltage Offset Correction: v_off_ini = 432.468 uV, v_off_fin = 422.253 uV 14:05:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -180.285 uVs 14:05:56 Integrated Voltage Measurement... 14:06:05 Voltage Offset Correction: v_off_ini = 440.315 uV, v_off_fin = 448.677 uV 14:06:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.341 uVs 14:06:05 Integrated Voltage Measurement... 14:06:14 Voltage Offset Correction: v_off_ini = 442.379 uV, v_off_fin = 436.867 uV 14:06:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.024 uVs 14:06:14 Integrated Voltage Measurement... 14:06:23 Voltage Offset Correction: v_off_ini = 438.119 uV, v_off_fin = 449.595 uV 14:06:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.791 uVs 14:06:23 Integrated Voltage Measurement... 14:06:32 Voltage Offset Correction: v_off_ini = 435.822 uV, v_off_fin = 427.087 uV 14:06:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.905 uVs 14:06:32 Integrated Voltage Measurement... 14:06:41 Voltage Offset Correction: v_off_ini = 438.305 uV, v_off_fin = 452.272 uV 14:06:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.595 uVs 14:06:45 I1Y Average and RMS of Measurements VT = -183.490 +- 5.922 uVs I1Y = -36.697 +- 1.184 uTm 14:06:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:53 Integrated Voltage Measurement... 14:07:02 Voltage Offset Correction: v_off_ini = 448.919 uV, v_off_fin = 434.845 uV 14:07:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.646 uVs 14:07:02 Integrated Voltage Measurement... 14:07:11 Voltage Offset Correction: v_off_ini = 453.267 uV, v_off_fin = 458.108 uV 14:07:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.478 uVs 14:07:11 Integrated Voltage Measurement... 14:07:20 Voltage Offset Correction: v_off_ini = 461.112 uV, v_off_fin = 451.451 uV 14:07:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.373 uVs 14:07:20 Integrated Voltage Measurement... 14:07:29 Voltage Offset Correction: v_off_ini = 456.679 uV, v_off_fin = 462.269 uV 14:07:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.213 uVs 14:07:29 Integrated Voltage Measurement... 14:07:38 Voltage Offset Correction: v_off_ini = 454.106 uV, v_off_fin = 452.065 uV 14:07:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.197 uVs 14:07:38 Integrated Voltage Measurement... 14:07:47 Voltage Offset Correction: v_off_ini = 433.784 uV, v_off_fin = 454.800 uV 14:07:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.796 uVs 14:07:49 I2X Average and RMS of Measurements VT = -99.284 +- 5.571 uVs I2X = 9.134 +- 0.513 uTm^2 14:07:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:57 Integrated Voltage Measurement... 14:08:06 Voltage Offset Correction: v_off_ini = 450.805 uV, v_off_fin = 436.322 uV 14:08:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.809 uVs 14:08:06 Integrated Voltage Measurement... 14:08:15 Voltage Offset Correction: v_off_ini = 432.129 uV, v_off_fin = 429.473 uV 14:08:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.912 uVs 14:08:15 Integrated Voltage Measurement... 14:08:24 Voltage Offset Correction: v_off_ini = 438.650 uV, v_off_fin = 434.041 uV 14:08:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.712 uVs 14:08:24 Integrated Voltage Measurement... 14:08:33 Voltage Offset Correction: v_off_ini = 444.028 uV, v_off_fin = 442.417 uV 14:08:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.037 uVs 14:08:33 Integrated Voltage Measurement... 14:08:42 Voltage Offset Correction: v_off_ini = 443.567 uV, v_off_fin = 452.036 uV 14:08:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.553 uVs 14:08:42 Integrated Voltage Measurement... 14:08:51 Voltage Offset Correction: v_off_ini = 463.617 uV, v_off_fin = 455.499 uV 14:08:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.922 uVs 14:08:54 I2Y Average and RMS of Measurements VT = -205.491 +- 6.445 uVs I2Y = -18.905 +- 0.593 uTm^2 14:09:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:12 Integrated Voltage Measurement... 14:09:21 Voltage Offset Correction: v_off_ini = 432.553 uV, v_off_fin = 431.623 uV 14:09:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.213 uVs 14:09:21 Integrated Voltage Measurement... 14:09:30 Voltage Offset Correction: v_off_ini = 430.611 uV, v_off_fin = 432.194 uV 14:09:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.477 uVs 14:09:30 Integrated Voltage Measurement... 14:09:39 Voltage Offset Correction: v_off_ini = 436.025 uV, v_off_fin = 435.573 uV 14:09:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.483 uVs 14:09:39 Integrated Voltage Measurement... 14:09:48 Voltage Offset Correction: v_off_ini = 429.138 uV, v_off_fin = 430.392 uV 14:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.356 uVs 14:09:48 Integrated Voltage Measurement... 14:09:57 Voltage Offset Correction: v_off_ini = 426.229 uV, v_off_fin = 416.599 uV 14:09:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.677 uVs 14:09:57 Integrated Voltage Measurement... 14:10:06 Voltage Offset Correction: v_off_ini = 422.984 uV, v_off_fin = 424.649 uV 14:10:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.940 uVs 14:10:11 I1X Average and RMS of Measurements VT = -88.858 +- 10.584 uVs I1X = 17.772 +- 2.117 uTm 14:10:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:17 Integrated Voltage Measurement... 14:10:26 Voltage Offset Correction: v_off_ini = 430.880 uV, v_off_fin = 426.253 uV 14:10:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.951 uVs 14:10:26 Integrated Voltage Measurement... 14:10:35 Voltage Offset Correction: v_off_ini = 435.498 uV, v_off_fin = 439.849 uV 14:10:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.537 uVs 14:10:35 Integrated Voltage Measurement... 14:10:44 Voltage Offset Correction: v_off_ini = 426.976 uV, v_off_fin = 410.083 uV 14:10:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.357 uVs 14:10:44 Integrated Voltage Measurement... 14:10:53 Voltage Offset Correction: v_off_ini = 437.391 uV, v_off_fin = 430.350 uV 14:10:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.267 uVs 14:10:53 Integrated Voltage Measurement... 14:11:02 Voltage Offset Correction: v_off_ini = 431.245 uV, v_off_fin = 419.922 uV 14:11:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.858 uVs 14:11:02 Integrated Voltage Measurement... 14:11:11 Voltage Offset Correction: v_off_ini = 434.047 uV, v_off_fin = 444.004 uV 14:11:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.202 uVs 14:11:16 I1Y Average and RMS of Measurements VT = -187.195 +- 6.914 uVs I1Y = -37.439 +- 1.383 uTm 14:11:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:23 Integrated Voltage Measurement... 14:11:32 Voltage Offset Correction: v_off_ini = 409.549 uV, v_off_fin = 400.635 uV 14:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.553 uVs 14:11:32 Integrated Voltage Measurement... 14:11:41 Voltage Offset Correction: v_off_ini = 415.878 uV, v_off_fin = 417.783 uV 14:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.963 uVs 14:11:41 Integrated Voltage Measurement... 14:11:50 Voltage Offset Correction: v_off_ini = 411.174 uV, v_off_fin = 406.827 uV 14:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.345 uVs 14:11:51 Integrated Voltage Measurement... 14:11:59 Voltage Offset Correction: v_off_ini = 422.538 uV, v_off_fin = 445.136 uV 14:12:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.482 uVs 14:12:00 Integrated Voltage Measurement... 14:12:09 Voltage Offset Correction: v_off_ini = 432.981 uV, v_off_fin = 416.923 uV 14:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.990 uVs 14:12:09 Integrated Voltage Measurement... 14:12:18 Voltage Offset Correction: v_off_ini = 427.407 uV, v_off_fin = 431.157 uV 14:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.598 uVs 14:12:20 I2X Average and RMS of Measurements VT = -86.489 +- 1.606 uVs I2X = 7.957 +- 0.148 uTm^2 14:12:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:28 Integrated Voltage Measurement... 14:12:37 Voltage Offset Correction: v_off_ini = 435.168 uV, v_off_fin = 433.798 uV 14:12:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -212.592 uVs 14:12:37 Integrated Voltage Measurement... 14:12:46 Voltage Offset Correction: v_off_ini = 425.332 uV, v_off_fin = 439.749 uV 14:12:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.659 uVs 14:12:46 Integrated Voltage Measurement... 14:12:55 Voltage Offset Correction: v_off_ini = 439.709 uV, v_off_fin = 424.114 uV 14:12:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.372 uVs 14:12:55 Integrated Voltage Measurement... 14:13:04 Voltage Offset Correction: v_off_ini = 420.616 uV, v_off_fin = 412.411 uV 14:13:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.182 uVs 14:13:04 Integrated Voltage Measurement... 14:13:13 Voltage Offset Correction: v_off_ini = 415.862 uV, v_off_fin = 420.744 uV 14:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.593 uVs 14:13:13 Integrated Voltage Measurement... 14:13:22 Voltage Offset Correction: v_off_ini = 422.773 uV, v_off_fin = 415.003 uV 14:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.306 uVs 14:13:24 I2Y Average and RMS of Measurements VT = -202.451 +- 1.440 uVs I2Y = -18.626 +- 0.133 uTm^2 14:13:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:43 Integrated Voltage Measurement... 14:13:52 Voltage Offset Correction: v_off_ini = 397.521 uV, v_off_fin = 398.180 uV 14:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.630 uVs 14:13:52 Integrated Voltage Measurement... 14:14:01 Voltage Offset Correction: v_off_ini = 403.085 uV, v_off_fin = 402.268 uV 14:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.572 uVs 14:14:01 Integrated Voltage Measurement... 14:14:10 Voltage Offset Correction: v_off_ini = 404.468 uV, v_off_fin = 402.414 uV 14:14:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.239 uVs 14:14:10 Integrated Voltage Measurement... 14:14:19 Voltage Offset Correction: v_off_ini = 379.252 uV, v_off_fin = 412.531 uV 14:14:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.237 uVs 14:14:19 Integrated Voltage Measurement... 14:14:28 Voltage Offset Correction: v_off_ini = 400.353 uV, v_off_fin = 391.104 uV 14:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.546 uVs 14:14:28 Integrated Voltage Measurement... 14:14:37 Voltage Offset Correction: v_off_ini = 405.815 uV, v_off_fin = 399.181 uV 14:14:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.319 uVs 14:14:41 I1X Average and RMS of Measurements VT = -85.757 +- 9.316 uVs I1X = 17.152 +- 1.863 uTm 14:14:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:48 Integrated Voltage Measurement... 14:14:57 Voltage Offset Correction: v_off_ini = 403.464 uV, v_off_fin = 383.874 uV 14:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -161.125 uVs 14:14:57 Integrated Voltage Measurement... 14:15:06 Voltage Offset Correction: v_off_ini = 405.484 uV, v_off_fin = 409.781 uV 14:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.639 uVs 14:15:06 Integrated Voltage Measurement... 14:15:15 Voltage Offset Correction: v_off_ini = 389.060 uV, v_off_fin = 388.663 uV 14:15:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.602 uVs 14:15:15 Integrated Voltage Measurement... 14:15:24 Voltage Offset Correction: v_off_ini = 399.715 uV, v_off_fin = 404.610 uV 14:15:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.524 uVs 14:15:24 Integrated Voltage Measurement... 14:15:33 Voltage Offset Correction: v_off_ini = 401.787 uV, v_off_fin = 386.696 uV 14:15:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.847 uVs 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = 400.907 uV, v_off_fin = 410.692 uV 14:15:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.600 uVs 14:15:46 I1Y Average and RMS of Measurements VT = -174.389 +- 9.433 uVs I1Y = -34.877 +- 1.887 uTm 14:15:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:54 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = 387.379 uV, v_off_fin = 385.642 uV 14:16:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -76.756 uVs 14:16:03 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 399.496 uV, v_off_fin = 395.388 uV 14:16:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.540 uVs 14:16:12 Integrated Voltage Measurement... 14:16:21 Voltage Offset Correction: v_off_ini = 389.742 uV, v_off_fin = 378.112 uV 14:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.491 uVs 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 381.075 uV, v_off_fin = 388.230 uV 14:16:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.491 uVs 14:16:30 Integrated Voltage Measurement... 14:16:39 Voltage Offset Correction: v_off_ini = 389.484 uV, v_off_fin = 358.777 uV 14:16:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.005 uVs 14:16:39 Integrated Voltage Measurement... 14:16:48 Voltage Offset Correction: v_off_ini = 378.474 uV, v_off_fin = 385.798 uV 14:16:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.140 uVs 14:16:50 I2X Average and RMS of Measurements VT = -84.070 +- 5.708 uVs I2X = 7.734 +- 0.525 uTm^2 14:16:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:58 Integrated Voltage Measurement... 14:17:07 Voltage Offset Correction: v_off_ini = 370.171 uV, v_off_fin = 366.482 uV 14:17:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.527 uVs 14:17:07 Integrated Voltage Measurement... 14:17:16 Voltage Offset Correction: v_off_ini = 368.480 uV, v_off_fin = 367.520 uV 14:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.728 uVs 14:17:16 Integrated Voltage Measurement... 14:17:25 Voltage Offset Correction: v_off_ini = 348.994 uV, v_off_fin = 349.855 uV 14:17:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.971 uVs 14:17:25 Integrated Voltage Measurement... 14:17:34 Voltage Offset Correction: v_off_ini = 352.496 uV, v_off_fin = 362.734 uV 14:17:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.497 uVs 14:17:34 Integrated Voltage Measurement... 14:17:43 Voltage Offset Correction: v_off_ini = 397.238 uV, v_off_fin = 387.940 uV 14:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.450 uVs 14:17:43 Integrated Voltage Measurement... 14:17:52 Voltage Offset Correction: v_off_ini = 374.707 uV, v_off_fin = 370.928 uV 14:17:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.420 uVs 14:17:55 I2Y Average and RMS of Measurements VT = -195.266 +- 11.389 uVs I2Y = -17.964 +- 1.048 uTm^2 14:17:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm