SLAC Magnetic Measurements Date: 11-21-2025 Time: 11:11:01 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16338 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 11:11:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:11 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:11:13 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:11:14 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:11:16 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:11:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:11:32 Integrated Voltage Measurement... 11:11:41 Voltage Offset Correction: v_off_ini = 319.275 uV, v_off_fin = 320.011 uV 11:11:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.900 uVs 11:11:41 Integrated Voltage Measurement... 11:11:50 Voltage Offset Correction: v_off_ini = 330.797 uV, v_off_fin = 325.954 uV 11:11:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.311 uVs 11:11:50 Integrated Voltage Measurement... 11:11:59 Voltage Offset Correction: v_off_ini = 319.217 uV, v_off_fin = 314.684 uV 11:11:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.414 uVs 11:11:59 Integrated Voltage Measurement... 11:12:08 Voltage Offset Correction: v_off_ini = 319.133 uV, v_off_fin = 328.344 uV 11:12:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.931 uVs 11:12:08 Integrated Voltage Measurement... 11:12:17 Voltage Offset Correction: v_off_ini = 314.471 uV, v_off_fin = 312.025 uV 11:12:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.189 uVs 11:12:17 Integrated Voltage Measurement... 11:12:26 Voltage Offset Correction: v_off_ini = 329.578 uV, v_off_fin = 329.347 uV 11:12:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.336 uVs 11:12:30 I1X Average and RMS of Measurements VT = -146.514 +- 3.256 uVs I1X = 29.303 +- 0.651 uTm 11:12:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:12:37 Integrated Voltage Measurement... 11:12:46 Voltage Offset Correction: v_off_ini = 310.621 uV, v_off_fin = 308.308 uV 11:12:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.387 uVs 11:12:46 Integrated Voltage Measurement... 11:12:55 Voltage Offset Correction: v_off_ini = 319.951 uV, v_off_fin = 326.696 uV 11:12:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.446 uVs 11:12:55 Integrated Voltage Measurement... 11:13:04 Voltage Offset Correction: v_off_ini = 308.032 uV, v_off_fin = 301.571 uV 11:13:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -131.395 uVs 11:13:04 Integrated Voltage Measurement... 11:13:13 Voltage Offset Correction: v_off_ini = 336.531 uV, v_off_fin = 334.769 uV 11:13:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 127.322 uVs 11:13:13 Integrated Voltage Measurement... 11:13:22 Voltage Offset Correction: v_off_ini = 312.529 uV, v_off_fin = 310.530 uV 11:13:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.880 uVs 11:13:22 Integrated Voltage Measurement... 11:13:31 Voltage Offset Correction: v_off_ini = 326.081 uV, v_off_fin = 332.715 uV 11:13:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 131.090 uVs 11:13:35 I1Y Average and RMS of Measurements VT = -135.753 +- 5.334 uVs I1Y = -27.151 +- 1.067 uTm 11:13:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:13:43 Integrated Voltage Measurement... 11:13:52 Voltage Offset Correction: v_off_ini = 338.958 uV, v_off_fin = 336.602 uV 11:13:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.248 uVs 11:13:52 Integrated Voltage Measurement... 11:14:01 Voltage Offset Correction: v_off_ini = 356.844 uV, v_off_fin = 356.393 uV 11:14:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 183.226 uVs 11:14:01 Integrated Voltage Measurement... 11:14:10 Voltage Offset Correction: v_off_ini = 359.158 uV, v_off_fin = 349.832 uV 11:14:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.144 uVs 11:14:10 Integrated Voltage Measurement... 11:14:19 Voltage Offset Correction: v_off_ini = 324.695 uV, v_off_fin = 349.769 uV 11:14:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 168.844 uVs 11:14:19 Integrated Voltage Measurement... 11:14:28 Voltage Offset Correction: v_off_ini = 369.967 uV, v_off_fin = 356.855 uV 11:14:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.529 uVs 11:14:28 Integrated Voltage Measurement... 11:14:37 Voltage Offset Correction: v_off_ini = 362.383 uV, v_off_fin = 361.089 uV 11:14:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 171.180 uVs 11:14:40 I2X Average and RMS of Measurements VT = -160.029 +- 2.928 uVs I2X = 14.723 +- 0.270 uTm^2 11:14:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:14:47 Integrated Voltage Measurement... 11:14:56 Voltage Offset Correction: v_off_ini = 367.460 uV, v_off_fin = 369.617 uV 11:14:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.093 uVs 11:14:56 Integrated Voltage Measurement... 11:15:05 Voltage Offset Correction: v_off_ini = 360.978 uV, v_off_fin = 365.196 uV 11:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.338 uVs 11:15:05 Integrated Voltage Measurement... 11:15:14 Voltage Offset Correction: v_off_ini = 352.198 uV, v_off_fin = 372.762 uV 11:15:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.343 uVs 11:15:14 Integrated Voltage Measurement... 11:15:23 Voltage Offset Correction: v_off_ini = 372.508 uV, v_off_fin = 393.960 uV 11:15:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.023 uVs 11:15:24 Integrated Voltage Measurement... 11:15:32 Voltage Offset Correction: v_off_ini = 368.326 uV, v_off_fin = 377.830 uV 11:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.769 uVs 11:15:33 Integrated Voltage Measurement... 11:15:42 Voltage Offset Correction: v_off_ini = 373.553 uV, v_off_fin = 369.224 uV 11:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.454 uVs 11:15:44 I2Y Average and RMS of Measurements VT = -178.504 +- 1.269 uVs I2Y = -16.422 +- 0.117 uTm^2 11:15:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:15:59 Integrated Voltage Measurement... 11:16:08 Voltage Offset Correction: v_off_ini = 398.037 uV, v_off_fin = 369.622 uV 11:16:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -182.189 uVs 11:16:08 Integrated Voltage Measurement... 11:16:17 Voltage Offset Correction: v_off_ini = 372.390 uV, v_off_fin = 378.337 uV 11:16:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.559 uVs 11:16:17 Integrated Voltage Measurement... 11:16:26 Voltage Offset Correction: v_off_ini = 376.427 uV, v_off_fin = 365.917 uV 11:16:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.340 uVs 11:16:26 Integrated Voltage Measurement... 11:16:35 Voltage Offset Correction: v_off_ini = 372.752 uV, v_off_fin = 365.380 uV 11:16:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 180.904 uVs 11:16:35 Integrated Voltage Measurement... 11:16:44 Voltage Offset Correction: v_off_ini = 368.415 uV, v_off_fin = 356.102 uV 11:16:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.863 uVs 11:16:44 Integrated Voltage Measurement... 11:16:53 Voltage Offset Correction: v_off_ini = 364.617 uV, v_off_fin = 356.711 uV 11:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 203.281 uVs 11:16:57 I1X Average and RMS of Measurements VT = -172.856 +- 3.025 uVs I1X = 34.572 +- 0.604 uTm 11:17:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:17:04 Integrated Voltage Measurement... 11:17:13 Voltage Offset Correction: v_off_ini = 361.958 uV, v_off_fin = 346.211 uV 11:17:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.612 uVs 11:17:13 Integrated Voltage Measurement... 11:17:22 Voltage Offset Correction: v_off_ini = 351.574 uV, v_off_fin = 359.291 uV 11:17:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.157 uVs 11:17:22 Integrated Voltage Measurement... 11:17:31 Voltage Offset Correction: v_off_ini = 352.502 uV, v_off_fin = 350.021 uV 11:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.310 uVs 11:17:31 Integrated Voltage Measurement... 11:17:40 Voltage Offset Correction: v_off_ini = 353.604 uV, v_off_fin = 358.930 uV 11:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 130.928 uVs 11:17:40 Integrated Voltage Measurement... 11:17:49 Voltage Offset Correction: v_off_ini = 366.153 uV, v_off_fin = 341.757 uV 11:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.597 uVs 11:17:49 Integrated Voltage Measurement... 11:17:58 Voltage Offset Correction: v_off_ini = 358.791 uV, v_off_fin = 377.700 uV 11:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 165.723 uVs 11:18:02 I1Y Average and RMS of Measurements VT = -152.388 +- 8.887 uVs I1Y = -30.476 +- 1.777 uTm 11:18:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:18:10 Integrated Voltage Measurement... 11:18:19 Voltage Offset Correction: v_off_ini = 339.610 uV, v_off_fin = 343.020 uV 11:18:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -181.113 uVs 11:18:19 Integrated Voltage Measurement... 11:18:28 Voltage Offset Correction: v_off_ini = 338.236 uV, v_off_fin = 337.430 uV 11:18:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 173.956 uVs 11:18:28 Integrated Voltage Measurement... 11:18:37 Voltage Offset Correction: v_off_ini = 328.872 uV, v_off_fin = 338.016 uV 11:18:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.466 uVs 11:18:37 Integrated Voltage Measurement... 11:18:46 Voltage Offset Correction: v_off_ini = 354.928 uV, v_off_fin = 366.290 uV 11:18:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.950 uVs 11:18:46 Integrated Voltage Measurement... 11:18:55 Voltage Offset Correction: v_off_ini = 351.021 uV, v_off_fin = 343.725 uV 11:18:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.188 uVs 11:18:55 Integrated Voltage Measurement... 11:19:04 Voltage Offset Correction: v_off_ini = 344.192 uV, v_off_fin = 345.649 uV 11:19:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 188.403 uVs 11:19:07 I2X Average and RMS of Measurements VT = -176.346 +- 0.951 uVs I2X = 16.224 +- 0.088 uTm^2 11:19:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:19:14 Integrated Voltage Measurement... 11:19:23 Voltage Offset Correction: v_off_ini = 338.141 uV, v_off_fin = 353.026 uV 11:19:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.415 uVs 11:19:23 Integrated Voltage Measurement... 11:19:32 Voltage Offset Correction: v_off_ini = 346.046 uV, v_off_fin = 344.725 uV 11:19:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.685 uVs 11:19:32 Integrated Voltage Measurement... 11:19:41 Voltage Offset Correction: v_off_ini = 343.849 uV, v_off_fin = 342.079 uV 11:19:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.557 uVs 11:19:41 Integrated Voltage Measurement... 11:19:50 Voltage Offset Correction: v_off_ini = 331.203 uV, v_off_fin = 343.261 uV 11:19:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.497 uVs 11:19:51 Integrated Voltage Measurement... 11:20:00 Voltage Offset Correction: v_off_ini = 335.827 uV, v_off_fin = 356.195 uV 11:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.422 uVs 11:20:00 Integrated Voltage Measurement... 11:20:09 Voltage Offset Correction: v_off_ini = 355.772 uV, v_off_fin = 351.293 uV 11:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.482 uVs 11:20:11 I2Y Average and RMS of Measurements VT = -193.176 +- 8.554 uVs I2Y = -17.772 +- 0.787 uTm^2 11:20:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:26 Integrated Voltage Measurement... 11:20:35 Voltage Offset Correction: v_off_ini = 333.972 uV, v_off_fin = 321.932 uV 11:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -185.696 uVs 11:20:35 Integrated Voltage Measurement... 11:20:44 Voltage Offset Correction: v_off_ini = 318.493 uV, v_off_fin = 329.223 uV 11:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 199.019 uVs 11:20:44 Integrated Voltage Measurement... 11:20:53 Voltage Offset Correction: v_off_ini = 333.543 uV, v_off_fin = 328.319 uV 11:20:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -204.566 uVs 11:20:53 Integrated Voltage Measurement... 11:21:02 Voltage Offset Correction: v_off_ini = 317.450 uV, v_off_fin = 329.318 uV 11:21:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 185.089 uVs 11:21:02 Integrated Voltage Measurement... 11:21:11 Voltage Offset Correction: v_off_ini = 317.316 uV, v_off_fin = 316.854 uV 11:21:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.934 uVs 11:21:11 Integrated Voltage Measurement... 11:21:20 Voltage Offset Correction: v_off_ini = 332.448 uV, v_off_fin = 345.480 uV 11:21:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.171 uVs 11:21:24 I1X Average and RMS of Measurements VT = -184.246 +- 13.257 uVs I1X = 36.850 +- 2.652 uTm 11:21:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:31 Integrated Voltage Measurement... 11:21:40 Voltage Offset Correction: v_off_ini = 357.539 uV, v_off_fin = 330.793 uV 11:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.899 uVs 11:21:40 Integrated Voltage Measurement... 11:21:49 Voltage Offset Correction: v_off_ini = 333.474 uV, v_off_fin = 347.387 uV 11:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.085 uVs 11:21:49 Integrated Voltage Measurement... 11:21:58 Voltage Offset Correction: v_off_ini = 346.524 uV, v_off_fin = 331.191 uV 11:21:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.485 uVs 11:21:58 Integrated Voltage Measurement... 11:22:07 Voltage Offset Correction: v_off_ini = 354.798 uV, v_off_fin = 335.024 uV 11:22:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.135 uVs 11:22:07 Integrated Voltage Measurement... 11:22:16 Voltage Offset Correction: v_off_ini = 321.009 uV, v_off_fin = 308.979 uV 11:22:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.059 uVs 11:22:16 Integrated Voltage Measurement... 11:22:25 Voltage Offset Correction: v_off_ini = 324.516 uV, v_off_fin = 338.185 uV 11:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.013 uVs 11:22:29 I1Y Average and RMS of Measurements VT = -162.613 +- 4.602 uVs I1Y = -32.521 +- 0.919 uTm 11:22:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:37 Integrated Voltage Measurement... 11:22:46 Voltage Offset Correction: v_off_ini = 339.237 uV, v_off_fin = 329.739 uV 11:22:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -221.621 uVs 11:22:46 Integrated Voltage Measurement... 11:22:55 Voltage Offset Correction: v_off_ini = 344.117 uV, v_off_fin = 339.350 uV 11:22:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 196.259 uVs 11:22:55 Integrated Voltage Measurement... 11:23:04 Voltage Offset Correction: v_off_ini = 325.519 uV, v_off_fin = 330.492 uV 11:23:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -188.451 uVs 11:23:04 Integrated Voltage Measurement... 11:23:13 Voltage Offset Correction: v_off_ini = 336.158 uV, v_off_fin = 345.338 uV 11:23:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 195.952 uVs 11:23:13 Integrated Voltage Measurement... 11:23:22 Voltage Offset Correction: v_off_ini = 324.324 uV, v_off_fin = 318.286 uV 11:23:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -189.896 uVs 11:23:22 Integrated Voltage Measurement... 11:23:31 Voltage Offset Correction: v_off_ini = 326.164 uV, v_off_fin = 341.036 uV 11:23:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 186.521 uVs 11:23:34 I2X Average and RMS of Measurements VT = -196.450 +- 8.981 uVs I2X = 18.073 +- 0.826 uTm^2 11:23:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:42 Integrated Voltage Measurement... 11:23:51 Voltage Offset Correction: v_off_ini = 329.389 uV, v_off_fin = 327.387 uV 11:23:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.485 uVs 11:23:51 Integrated Voltage Measurement... 11:24:00 Voltage Offset Correction: v_off_ini = 333.210 uV, v_off_fin = 333.947 uV 11:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.318 uVs 11:24:00 Integrated Voltage Measurement... 11:24:09 Voltage Offset Correction: v_off_ini = 323.823 uV, v_off_fin = 334.811 uV 11:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.745 uVs 11:24:09 Integrated Voltage Measurement... 11:24:18 Voltage Offset Correction: v_off_ini = 322.773 uV, v_off_fin = 328.804 uV 11:24:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.234 uVs 11:24:18 Integrated Voltage Measurement... 11:24:27 Voltage Offset Correction: v_off_ini = 330.700 uV, v_off_fin = 318.360 uV 11:24:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.894 uVs 11:24:27 Integrated Voltage Measurement... 11:24:36 Voltage Offset Correction: v_off_ini = 306.742 uV, v_off_fin = 326.819 uV 11:24:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.826 uVs 11:24:38 I2Y Average and RMS of Measurements VT = -202.084 +- 9.226 uVs I2Y = -18.592 +- 0.849 uTm^2 11:24:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:53 Integrated Voltage Measurement... 11:25:02 Voltage Offset Correction: v_off_ini = 337.358 uV, v_off_fin = 340.135 uV 11:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -202.259 uVs 11:25:02 Integrated Voltage Measurement... 11:25:11 Voltage Offset Correction: v_off_ini = 334.648 uV, v_off_fin = 330.889 uV 11:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 194.035 uVs 11:25:11 Integrated Voltage Measurement... 11:25:20 Voltage Offset Correction: v_off_ini = 330.904 uV, v_off_fin = 326.817 uV 11:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -185.580 uVs 11:25:20 Integrated Voltage Measurement... 11:25:29 Voltage Offset Correction: v_off_ini = 321.418 uV, v_off_fin = 331.090 uV 11:25:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 202.384 uVs 11:25:29 Integrated Voltage Measurement... 11:25:38 Voltage Offset Correction: v_off_ini = 324.758 uV, v_off_fin = 328.952 uV 11:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.293 uVs 11:25:38 Integrated Voltage Measurement... 11:25:47 Voltage Offset Correction: v_off_ini = 334.632 uV, v_off_fin = 318.734 uV 11:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 192.405 uVs 11:25:52 I1X Average and RMS of Measurements VT = -195.993 +- 1.703 uVs I1X = 39.200 +- 0.341 uTm 11:25:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:58 Integrated Voltage Measurement... 11:26:07 Voltage Offset Correction: v_off_ini = 311.989 uV, v_off_fin = 289.467 uV 11:26:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -157.921 uVs 11:26:07 Integrated Voltage Measurement... 11:26:16 Voltage Offset Correction: v_off_ini = 335.263 uV, v_off_fin = 334.424 uV 11:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 159.212 uVs 11:26:16 Integrated Voltage Measurement... 11:26:25 Voltage Offset Correction: v_off_ini = 327.018 uV, v_off_fin = 303.467 uV 11:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.836 uVs 11:26:25 Integrated Voltage Measurement... 11:26:34 Voltage Offset Correction: v_off_ini = 332.454 uV, v_off_fin = 339.014 uV 11:26:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.254 uVs 11:26:34 Integrated Voltage Measurement... 11:26:43 Voltage Offset Correction: v_off_ini = 300.920 uV, v_off_fin = 292.000 uV 11:26:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.862 uVs 11:26:44 Integrated Voltage Measurement... 11:26:53 Voltage Offset Correction: v_off_ini = 308.142 uV, v_off_fin = 342.381 uV 11:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.535 uVs 11:26:57 I1Y Average and RMS of Measurements VT = -163.937 +- 8.216 uVs I1Y = -32.786 +- 1.643 uTm 11:27:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:27:05 Integrated Voltage Measurement... 11:27:14 Voltage Offset Correction: v_off_ini = 319.608 uV, v_off_fin = 300.514 uV 11:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.037 uVs 11:27:14 Integrated Voltage Measurement... 11:27:23 Voltage Offset Correction: v_off_ini = 315.348 uV, v_off_fin = 311.009 uV 11:27:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.557 uVs 11:27:23 Integrated Voltage Measurement... 11:27:32 Voltage Offset Correction: v_off_ini = 298.264 uV, v_off_fin = 301.859 uV 11:27:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -186.537 uVs 11:27:32 Integrated Voltage Measurement... 11:27:41 Voltage Offset Correction: v_off_ini = 311.231 uV, v_off_fin = 326.199 uV 11:27:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 199.045 uVs 11:27:41 Integrated Voltage Measurement... 11:27:50 Voltage Offset Correction: v_off_ini = 303.316 uV, v_off_fin = 299.022 uV 11:27:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -208.068 uVs 11:27:50 Integrated Voltage Measurement... 11:27:59 Voltage Offset Correction: v_off_ini = 316.041 uV, v_off_fin = 317.018 uV 11:27:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 188.228 uVs 11:28:01 I2X Average and RMS of Measurements VT = -193.246 +- 3.831 uVs I2X = 17.779 +- 0.352 uTm^2 11:28:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:28:09 Integrated Voltage Measurement... 11:28:18 Voltage Offset Correction: v_off_ini = 313.538 uV, v_off_fin = 311.646 uV 11:28:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.122 uVs 11:28:18 Integrated Voltage Measurement... 11:28:27 Voltage Offset Correction: v_off_ini = 316.547 uV, v_off_fin = 312.380 uV 11:28:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.260 uVs 11:28:27 Integrated Voltage Measurement... 11:28:36 Voltage Offset Correction: v_off_ini = 325.840 uV, v_off_fin = 310.724 uV 11:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.488 uVs 11:28:36 Integrated Voltage Measurement... 11:28:45 Voltage Offset Correction: v_off_ini = 311.112 uV, v_off_fin = 322.183 uV 11:28:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.280 uVs 11:28:45 Integrated Voltage Measurement... 11:28:54 Voltage Offset Correction: v_off_ini = 340.721 uV, v_off_fin = 329.134 uV 11:28:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.194 uVs 11:28:54 Integrated Voltage Measurement... 11:29:03 Voltage Offset Correction: v_off_ini = 339.220 uV, v_off_fin = 307.392 uV 11:29:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.382 uVs 11:29:06 I2Y Average and RMS of Measurements VT = -216.621 +- 5.938 uVs I2Y = -19.929 +- 0.546 uTm^2 11:29:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:29:21 Integrated Voltage Measurement... 11:29:30 Voltage Offset Correction: v_off_ini = 344.510 uV, v_off_fin = 314.216 uV 11:29:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -235.528 uVs 11:29:30 Integrated Voltage Measurement... 11:29:39 Voltage Offset Correction: v_off_ini = 323.976 uV, v_off_fin = 329.354 uV 11:29:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 231.909 uVs 11:29:39 Integrated Voltage Measurement... 11:29:48 Voltage Offset Correction: v_off_ini = 319.132 uV, v_off_fin = 318.509 uV 11:29:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.144 uVs 11:29:48 Integrated Voltage Measurement... 11:29:57 Voltage Offset Correction: v_off_ini = 330.899 uV, v_off_fin = 330.931 uV 11:29:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 194.936 uVs 11:29:57 Integrated Voltage Measurement... 11:30:06 Voltage Offset Correction: v_off_ini = 333.361 uV, v_off_fin = 328.113 uV 11:30:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -202.999 uVs 11:30:06 Integrated Voltage Measurement... 11:30:15 Voltage Offset Correction: v_off_ini = 362.490 uV, v_off_fin = 356.188 uV 11:30:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 210.945 uVs 11:30:19 I1X Average and RMS of Measurements VT = -212.744 +- 15.323 uVs I1X = 42.549 +- 3.065 uTm 11:30:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:30:26 Integrated Voltage Measurement... 11:30:35 Voltage Offset Correction: v_off_ini = 345.728 uV, v_off_fin = 338.148 uV 11:30:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.304 uVs 11:30:35 Integrated Voltage Measurement... 11:30:44 Voltage Offset Correction: v_off_ini = 352.248 uV, v_off_fin = 358.491 uV 11:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.645 uVs 11:30:44 Integrated Voltage Measurement... 11:30:53 Voltage Offset Correction: v_off_ini = 360.155 uV, v_off_fin = 350.182 uV 11:30:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.670 uVs 11:30:53 Integrated Voltage Measurement... 11:31:02 Voltage Offset Correction: v_off_ini = 369.588 uV, v_off_fin = 378.413 uV 11:31:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.854 uVs 11:31:02 Integrated Voltage Measurement... 11:31:11 Voltage Offset Correction: v_off_ini = 363.878 uV, v_off_fin = 353.442 uV 11:31:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.791 uVs 11:31:11 Integrated Voltage Measurement... 11:31:20 Voltage Offset Correction: v_off_ini = 380.313 uV, v_off_fin = 376.117 uV 11:31:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.621 uVs 11:31:24 I1Y Average and RMS of Measurements VT = -183.647 +- 2.674 uVs I1Y = -36.728 +- 0.535 uTm 11:31:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:31:32 Integrated Voltage Measurement... 11:31:41 Voltage Offset Correction: v_off_ini = 368.585 uV, v_off_fin = 362.764 uV 11:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -209.613 uVs 11:31:41 Integrated Voltage Measurement... 11:31:50 Voltage Offset Correction: v_off_ini = 367.183 uV, v_off_fin = 377.487 uV 11:31:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 198.127 uVs 11:31:50 Integrated Voltage Measurement... 11:31:59 Voltage Offset Correction: v_off_ini = 378.377 uV, v_off_fin = 369.597 uV 11:31:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -214.593 uVs 11:31:59 Integrated Voltage Measurement... 11:32:08 Voltage Offset Correction: v_off_ini = 381.702 uV, v_off_fin = 401.767 uV 11:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 225.370 uVs 11:32:08 Integrated Voltage Measurement... 11:32:17 Voltage Offset Correction: v_off_ini = 378.851 uV, v_off_fin = 365.681 uV 11:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -207.123 uVs 11:32:17 Integrated Voltage Measurement... 11:32:26 Voltage Offset Correction: v_off_ini = 365.905 uV, v_off_fin = 412.027 uV 11:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 233.593 uVs 11:32:28 I2X Average and RMS of Measurements VT = -214.736 +- 7.685 uVs I2X = 19.756 +- 0.707 uTm^2 11:32:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:32:36 Integrated Voltage Measurement... 11:32:45 Voltage Offset Correction: v_off_ini = 381.246 uV, v_off_fin = 383.039 uV 11:32:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.664 uVs 11:32:45 Integrated Voltage Measurement... 11:32:54 Voltage Offset Correction: v_off_ini = 380.570 uV, v_off_fin = 384.449 uV 11:32:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.407 uVs 11:32:54 Integrated Voltage Measurement... 11:33:03 Voltage Offset Correction: v_off_ini = 373.949 uV, v_off_fin = 363.000 uV 11:33:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.403 uVs 11:33:03 Integrated Voltage Measurement... 11:33:12 Voltage Offset Correction: v_off_ini = 348.946 uV, v_off_fin = 351.653 uV 11:33:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.177 uVs 11:33:12 Integrated Voltage Measurement... 11:33:21 Voltage Offset Correction: v_off_ini = 349.142 uV, v_off_fin = 344.530 uV 11:33:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.302 uVs 11:33:21 Integrated Voltage Measurement... 11:33:30 Voltage Offset Correction: v_off_ini = 347.308 uV, v_off_fin = 339.611 uV 11:33:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.949 uVs 11:33:33 I2Y Average and RMS of Measurements VT = -219.150 +- 6.033 uVs I2Y = -20.162 +- 0.555 uTm^2 11:33:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:33:48 Integrated Voltage Measurement... 11:33:57 Voltage Offset Correction: v_off_ini = 359.145 uV, v_off_fin = 347.219 uV 11:33:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -244.490 uVs 11:33:57 Integrated Voltage Measurement... 11:34:06 Voltage Offset Correction: v_off_ini = 347.862 uV, v_off_fin = 349.531 uV 11:34:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 206.686 uVs 11:34:06 Integrated Voltage Measurement... 11:34:15 Voltage Offset Correction: v_off_ini = 369.981 uV, v_off_fin = 356.468 uV 11:34:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -218.329 uVs 11:34:15 Integrated Voltage Measurement... 11:34:24 Voltage Offset Correction: v_off_ini = 355.070 uV, v_off_fin = 344.976 uV 11:34:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 227.673 uVs 11:34:24 Integrated Voltage Measurement... 11:34:33 Voltage Offset Correction: v_off_ini = 340.092 uV, v_off_fin = 344.161 uV 11:34:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -231.696 uVs 11:34:33 Integrated Voltage Measurement... 11:34:42 Voltage Offset Correction: v_off_ini = 350.402 uV, v_off_fin = 346.806 uV 11:34:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 222.262 uVs 11:34:46 I1X Average and RMS of Measurements VT = -225.189 +- 1.648 uVs I1X = 45.040 +- 0.330 uTm 11:34:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:34:53 Integrated Voltage Measurement... 11:35:02 Voltage Offset Correction: v_off_ini = 331.180 uV, v_off_fin = 315.957 uV 11:35:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.667 uVs 11:35:02 Integrated Voltage Measurement... 11:35:11 Voltage Offset Correction: v_off_ini = 319.270 uV, v_off_fin = 340.310 uV 11:35:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.093 uVs 11:35:11 Integrated Voltage Measurement... 11:35:20 Voltage Offset Correction: v_off_ini = 359.028 uV, v_off_fin = 356.049 uV 11:35:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.738 uVs 11:35:20 Integrated Voltage Measurement... 11:35:29 Voltage Offset Correction: v_off_ini = 351.807 uV, v_off_fin = 358.358 uV 11:35:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.232 uVs 11:35:29 Integrated Voltage Measurement... 11:35:38 Voltage Offset Correction: v_off_ini = 363.438 uV, v_off_fin = 351.790 uV 11:35:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.056 uVs 11:35:38 Integrated Voltage Measurement... 11:35:47 Voltage Offset Correction: v_off_ini = 359.748 uV, v_off_fin = 380.612 uV 11:35:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.844 uVs 11:35:51 I1Y Average and RMS of Measurements VT = -193.438 +- 2.653 uVs I1Y = -38.684 +- 0.531 uTm 11:35:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:35:59 Integrated Voltage Measurement... 11:36:08 Voltage Offset Correction: v_off_ini = 326.359 uV, v_off_fin = 337.498 uV 11:36:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -218.714 uVs 11:36:08 Integrated Voltage Measurement... 11:36:17 Voltage Offset Correction: v_off_ini = 362.305 uV, v_off_fin = 371.966 uV 11:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 220.654 uVs 11:36:17 Integrated Voltage Measurement... 11:36:26 Voltage Offset Correction: v_off_ini = 355.456 uV, v_off_fin = 341.216 uV 11:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -225.242 uVs 11:36:26 Integrated Voltage Measurement... 11:36:35 Voltage Offset Correction: v_off_ini = 348.289 uV, v_off_fin = 350.978 uV 11:36:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 209.450 uVs 11:36:35 Integrated Voltage Measurement... 11:36:44 Voltage Offset Correction: v_off_ini = 360.682 uV, v_off_fin = 336.978 uV 11:36:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -243.296 uVs 11:36:44 Integrated Voltage Measurement... 11:36:53 Voltage Offset Correction: v_off_ini = 362.743 uV, v_off_fin = 352.575 uV 11:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 205.597 uVs 11:36:55 I2X Average and RMS of Measurements VT = -220.492 +- 2.954 uVs I2X = 20.285 +- 0.272 uTm^2 11:37:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:37:03 Integrated Voltage Measurement... 11:37:12 Voltage Offset Correction: v_off_ini = 338.996 uV, v_off_fin = 339.926 uV 11:37:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.574 uVs 11:37:12 Integrated Voltage Measurement... 11:37:21 Voltage Offset Correction: v_off_ini = 350.845 uV, v_off_fin = 339.337 uV 11:37:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.145 uVs 11:37:21 Integrated Voltage Measurement... 11:37:30 Voltage Offset Correction: v_off_ini = 336.086 uV, v_off_fin = 327.603 uV 11:37:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.042 uVs 11:37:30 Integrated Voltage Measurement... 11:37:39 Voltage Offset Correction: v_off_ini = 341.391 uV, v_off_fin = 325.206 uV 11:37:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.905 uVs 11:37:39 Integrated Voltage Measurement... 11:37:48 Voltage Offset Correction: v_off_ini = 348.338 uV, v_off_fin = 350.184 uV 11:37:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.380 uVs 11:37:48 Integrated Voltage Measurement... 11:37:57 Voltage Offset Correction: v_off_ini = 340.394 uV, v_off_fin = 343.119 uV 11:37:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.087 uVs 11:38:00 I2Y Average and RMS of Measurements VT = -225.189 +- 8.012 uVs I2Y = -20.717 +- 0.737 uTm^2 11:38:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:38:15 Integrated Voltage Measurement... 11:38:23 Voltage Offset Correction: v_off_ini = 331.822 uV, v_off_fin = 315.143 uV 11:38:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -203.642 uVs 11:38:24 Integrated Voltage Measurement... 11:38:33 Voltage Offset Correction: v_off_ini = 325.651 uV, v_off_fin = 339.848 uV 11:38:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 218.131 uVs 11:38:33 Integrated Voltage Measurement... 11:38:42 Voltage Offset Correction: v_off_ini = 345.463 uV, v_off_fin = 333.274 uV 11:38:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -226.335 uVs 11:38:42 Integrated Voltage Measurement... 11:38:51 Voltage Offset Correction: v_off_ini = 345.222 uV, v_off_fin = 345.536 uV 11:38:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 217.514 uVs 11:38:51 Integrated Voltage Measurement... 11:39:00 Voltage Offset Correction: v_off_ini = 336.841 uV, v_off_fin = 324.676 uV 11:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -221.587 uVs 11:39:00 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 331.944 uV, v_off_fin = 341.716 uV 11:39:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 216.875 uVs 11:39:13 I1X Average and RMS of Measurements VT = -217.347 +- 4.699 uVs I1X = 43.469 +- 0.940 uTm 11:39:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:39:20 Integrated Voltage Measurement... 11:39:29 Voltage Offset Correction: v_off_ini = 331.687 uV, v_off_fin = 313.521 uV 11:39:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.282 uVs 11:39:29 Integrated Voltage Measurement... 11:39:38 Voltage Offset Correction: v_off_ini = 320.548 uV, v_off_fin = 344.554 uV 11:39:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.837 uVs 11:39:38 Integrated Voltage Measurement... 11:39:47 Voltage Offset Correction: v_off_ini = 356.369 uV, v_off_fin = 339.306 uV 11:39:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.258 uVs 11:39:47 Integrated Voltage Measurement... 11:39:56 Voltage Offset Correction: v_off_ini = 326.731 uV, v_off_fin = 333.076 uV 11:39:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.682 uVs 11:39:56 Integrated Voltage Measurement... 11:40:05 Voltage Offset Correction: v_off_ini = 321.913 uV, v_off_fin = 311.069 uV 11:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.059 uVs 11:40:05 Integrated Voltage Measurement... 11:40:14 Voltage Offset Correction: v_off_ini = 324.820 uV, v_off_fin = 336.041 uV 11:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.028 uVs 11:40:18 I1Y Average and RMS of Measurements VT = -200.524 +- 2.135 uVs I1Y = -40.102 +- 0.428 uTm 11:40:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:40:26 Integrated Voltage Measurement... 11:40:34 Voltage Offset Correction: v_off_ini = 337.064 uV, v_off_fin = 332.250 uV 11:40:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -212.873 uVs 11:40:35 Integrated Voltage Measurement... 11:40:44 Voltage Offset Correction: v_off_ini = 343.315 uV, v_off_fin = 343.638 uV 11:40:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 217.858 uVs 11:40:44 Integrated Voltage Measurement... 11:40:53 Voltage Offset Correction: v_off_ini = 353.264 uV, v_off_fin = 333.938 uV 11:40:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -248.796 uVs 11:40:53 Integrated Voltage Measurement... 11:41:02 Voltage Offset Correction: v_off_ini = 361.817 uV, v_off_fin = 357.683 uV 11:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 204.387 uVs 11:41:02 Integrated Voltage Measurement... 11:41:11 Voltage Offset Correction: v_off_ini = 345.014 uV, v_off_fin = 358.303 uV 11:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -215.081 uVs 11:41:11 Integrated Voltage Measurement... 11:41:20 Voltage Offset Correction: v_off_ini = 364.631 uV, v_off_fin = 357.302 uV 11:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 234.738 uVs 11:41:22 I2X Average and RMS of Measurements VT = -222.289 +- 4.943 uVs I2X = 20.451 +- 0.455 uTm^2 11:41:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:30 Integrated Voltage Measurement... 11:41:39 Voltage Offset Correction: v_off_ini = 356.738 uV, v_off_fin = 355.762 uV 11:41:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.296 uVs 11:41:39 Integrated Voltage Measurement... 11:41:48 Voltage Offset Correction: v_off_ini = 361.288 uV, v_off_fin = 362.162 uV 11:41:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.999 uVs 11:41:48 Integrated Voltage Measurement... 11:41:57 Voltage Offset Correction: v_off_ini = 345.990 uV, v_off_fin = 351.387 uV 11:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.514 uVs 11:41:57 Integrated Voltage Measurement... 11:42:06 Voltage Offset Correction: v_off_ini = 368.972 uV, v_off_fin = 366.543 uV 11:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.049 uVs 11:42:06 Integrated Voltage Measurement... 11:42:15 Voltage Offset Correction: v_off_ini = 390.980 uV, v_off_fin = 374.535 uV 11:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.031 uVs 11:42:15 Integrated Voltage Measurement... 11:42:24 Voltage Offset Correction: v_off_ini = 360.195 uV, v_off_fin = 355.390 uV 11:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.227 uVs 11:42:26 I2Y Average and RMS of Measurements VT = -235.519 +- 2.120 uVs I2Y = -21.668 +- 0.195 uTm^2 11:42:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:41 Integrated Voltage Measurement... 11:42:50 Voltage Offset Correction: v_off_ini = 368.109 uV, v_off_fin = 347.475 uV 11:42:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -230.934 uVs 11:42:50 Integrated Voltage Measurement... 11:42:59 Voltage Offset Correction: v_off_ini = 347.213 uV, v_off_fin = 324.939 uV 11:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 253.478 uVs 11:42:59 Integrated Voltage Measurement... 11:43:08 Voltage Offset Correction: v_off_ini = 359.252 uV, v_off_fin = 340.207 uV 11:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -215.679 uVs 11:43:08 Integrated Voltage Measurement... 11:43:17 Voltage Offset Correction: v_off_ini = 358.779 uV, v_off_fin = 345.247 uV 11:43:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 222.860 uVs 11:43:17 Integrated Voltage Measurement... 11:43:26 Voltage Offset Correction: v_off_ini = 327.570 uV, v_off_fin = 336.154 uV 11:43:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -241.549 uVs 11:43:26 Integrated Voltage Measurement... 11:43:35 Voltage Offset Correction: v_off_ini = 329.461 uV, v_off_fin = 333.127 uV 11:43:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 218.983 uVs 11:43:39 I1X Average and RMS of Measurements VT = -230.580 +- 9.367 uVs I1X = 46.116 +- 1.873 uTm 11:43:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:43:46 Integrated Voltage Measurement... 11:43:55 Voltage Offset Correction: v_off_ini = 337.189 uV, v_off_fin = 326.937 uV 11:43:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.976 uVs 11:43:55 Integrated Voltage Measurement... 11:44:04 Voltage Offset Correction: v_off_ini = 333.940 uV, v_off_fin = 335.864 uV 11:44:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.135 uVs 11:44:04 Integrated Voltage Measurement... 11:44:13 Voltage Offset Correction: v_off_ini = 330.541 uV, v_off_fin = 317.893 uV 11:44:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.153 uVs 11:44:13 Integrated Voltage Measurement... 11:44:22 Voltage Offset Correction: v_off_ini = 325.335 uV, v_off_fin = 348.515 uV 11:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.642 uVs 11:44:22 Integrated Voltage Measurement... 11:44:31 Voltage Offset Correction: v_off_ini = 335.077 uV, v_off_fin = 314.391 uV 11:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.493 uVs 11:44:31 Integrated Voltage Measurement... 11:44:40 Voltage Offset Correction: v_off_ini = 337.275 uV, v_off_fin = 346.816 uV 11:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.332 uVs 11:44:44 I1Y Average and RMS of Measurements VT = -200.622 +- 11.281 uVs I1Y = -40.123 +- 2.256 uTm 11:44:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:52 Integrated Voltage Measurement... 11:45:01 Voltage Offset Correction: v_off_ini = 326.143 uV, v_off_fin = 317.447 uV 11:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -237.645 uVs 11:45:01 Integrated Voltage Measurement... 11:45:10 Voltage Offset Correction: v_off_ini = 322.581 uV, v_off_fin = 334.179 uV 11:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 208.562 uVs 11:45:10 Integrated Voltage Measurement... 11:45:19 Voltage Offset Correction: v_off_ini = 314.235 uV, v_off_fin = 311.104 uV 11:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -222.255 uVs 11:45:19 Integrated Voltage Measurement... 11:45:28 Voltage Offset Correction: v_off_ini = 305.954 uV, v_off_fin = 335.417 uV 11:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 256.070 uVs 11:45:28 Integrated Voltage Measurement... 11:45:37 Voltage Offset Correction: v_off_ini = 333.424 uV, v_off_fin = 320.012 uV 11:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -220.664 uVs 11:45:37 Integrated Voltage Measurement... 11:45:46 Voltage Offset Correction: v_off_ini = 308.870 uV, v_off_fin = 337.705 uV 11:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 238.501 uVs 11:45:49 I2X Average and RMS of Measurements VT = -230.616 +- 6.597 uVs I2X = 21.217 +- 0.607 uTm^2 11:45:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:56 Integrated Voltage Measurement... 11:46:05 Voltage Offset Correction: v_off_ini = 339.265 uV, v_off_fin = 329.106 uV 11:46:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.294 uVs 11:46:05 Integrated Voltage Measurement... 11:46:14 Voltage Offset Correction: v_off_ini = 323.190 uV, v_off_fin = 321.937 uV 11:46:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.986 uVs 11:46:14 Integrated Voltage Measurement... 11:46:23 Voltage Offset Correction: v_off_ini = 333.208 uV, v_off_fin = 325.339 uV 11:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.333 uVs 11:46:23 Integrated Voltage Measurement... 11:46:32 Voltage Offset Correction: v_off_ini = 332.745 uV, v_off_fin = 327.029 uV 11:46:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.147 uVs 11:46:32 Integrated Voltage Measurement... 11:46:41 Voltage Offset Correction: v_off_ini = 326.474 uV, v_off_fin = 319.873 uV 11:46:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.428 uVs 11:46:41 Integrated Voltage Measurement... 11:46:50 Voltage Offset Correction: v_off_ini = 318.609 uV, v_off_fin = 325.602 uV 11:46:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.146 uVs 11:46:53 I2Y Average and RMS of Measurements VT = -235.722 +- 7.062 uVs I2Y = -21.686 +- 0.650 uTm^2 11:47:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:08 Integrated Voltage Measurement... 11:47:17 Voltage Offset Correction: v_off_ini = 346.692 uV, v_off_fin = 322.307 uV 11:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -229.090 uVs 11:47:17 Integrated Voltage Measurement... 11:47:26 Voltage Offset Correction: v_off_ini = 337.356 uV, v_off_fin = 343.072 uV 11:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 232.005 uVs 11:47:26 Integrated Voltage Measurement... 11:47:35 Voltage Offset Correction: v_off_ini = 317.853 uV, v_off_fin = 309.526 uV 11:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -226.244 uVs 11:47:35 Integrated Voltage Measurement... 11:47:44 Voltage Offset Correction: v_off_ini = 316.277 uV, v_off_fin = 309.397 uV 11:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 231.054 uVs 11:47:44 Integrated Voltage Measurement... 11:47:53 Voltage Offset Correction: v_off_ini = 306.664 uV, v_off_fin = 314.302 uV 11:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -241.161 uVs 11:47:53 Integrated Voltage Measurement... 11:48:02 Voltage Offset Correction: v_off_ini = 317.321 uV, v_off_fin = 320.512 uV 11:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 228.046 uVs 11:48:06 I1X Average and RMS of Measurements VT = -231.267 +- 2.484 uVs I1X = 46.253 +- 0.497 uTm 11:48:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:13 Integrated Voltage Measurement... 11:48:22 Voltage Offset Correction: v_off_ini = 326.359 uV, v_off_fin = 306.017 uV 11:48:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.072 uVs 11:48:22 Integrated Voltage Measurement... 11:48:31 Voltage Offset Correction: v_off_ini = 321.210 uV, v_off_fin = 311.937 uV 11:48:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.532 uVs 11:48:31 Integrated Voltage Measurement... 11:48:40 Voltage Offset Correction: v_off_ini = 300.377 uV, v_off_fin = 295.131 uV 11:48:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.990 uVs 11:48:40 Integrated Voltage Measurement... 11:48:49 Voltage Offset Correction: v_off_ini = 309.536 uV, v_off_fin = 325.643 uV 11:48:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 218.000 uVs 11:48:49 Integrated Voltage Measurement... 11:48:58 Voltage Offset Correction: v_off_ini = 339.786 uV, v_off_fin = 341.220 uV 11:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -217.357 uVs 11:48:58 Integrated Voltage Measurement... 11:49:07 Voltage Offset Correction: v_off_ini = 369.968 uV, v_off_fin = 364.376 uV 11:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.918 uVs 11:49:11 I1Y Average and RMS of Measurements VT = -208.645 +- 8.007 uVs I1Y = -41.724 +- 1.603 uTm 11:49:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:49:18 Integrated Voltage Measurement... 11:49:27 Voltage Offset Correction: v_off_ini = 324.466 uV, v_off_fin = 323.729 uV 11:49:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -209.769 uVs 11:49:27 Integrated Voltage Measurement... 11:49:36 Voltage Offset Correction: v_off_ini = 330.896 uV, v_off_fin = 338.477 uV 11:49:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 208.437 uVs 11:49:37 Integrated Voltage Measurement... 11:49:45 Voltage Offset Correction: v_off_ini = 321.080 uV, v_off_fin = 323.849 uV 11:49:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -242.185 uVs 11:49:46 Integrated Voltage Measurement... 11:49:55 Voltage Offset Correction: v_off_ini = 359.164 uV, v_off_fin = 351.143 uV 11:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 223.998 uVs 11:49:55 Integrated Voltage Measurement... 11:50:04 Voltage Offset Correction: v_off_ini = 354.177 uV, v_off_fin = 336.340 uV 11:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -212.762 uVs 11:50:04 Integrated Voltage Measurement... 11:50:13 Voltage Offset Correction: v_off_ini = 338.302 uV, v_off_fin = 348.812 uV 11:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 230.837 uVs 11:50:15 I2X Average and RMS of Measurements VT = -221.331 +- 9.799 uVs I2X = 20.362 +- 0.901 uTm^2 11:50:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:50:23 Integrated Voltage Measurement... 11:50:32 Voltage Offset Correction: v_off_ini = 330.448 uV, v_off_fin = 333.653 uV 11:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.513 uVs 11:50:32 Integrated Voltage Measurement... 11:50:41 Voltage Offset Correction: v_off_ini = 353.159 uV, v_off_fin = 347.481 uV 11:50:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.357 uVs 11:50:41 Integrated Voltage Measurement... 11:50:50 Voltage Offset Correction: v_off_ini = 341.311 uV, v_off_fin = 341.235 uV 11:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.654 uVs 11:50:50 Integrated Voltage Measurement... 11:50:59 Voltage Offset Correction: v_off_ini = 332.784 uV, v_off_fin = 331.272 uV 11:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.633 uVs 11:50:59 Integrated Voltage Measurement... 11:51:08 Voltage Offset Correction: v_off_ini = 326.179 uV, v_off_fin = 344.176 uV 11:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.179 uVs 11:51:08 Integrated Voltage Measurement... 11:51:17 Voltage Offset Correction: v_off_ini = 342.826 uV, v_off_fin = 342.782 uV 11:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.239 uVs 11:51:19 I2Y Average and RMS of Measurements VT = -233.096 +- 7.477 uVs I2Y = -21.445 +- 0.688 uTm^2 11:51:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:51:34 Integrated Voltage Measurement... 11:51:43 Voltage Offset Correction: v_off_ini = 334.231 uV, v_off_fin = 336.123 uV 11:51:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -232.046 uVs 11:51:43 Integrated Voltage Measurement... 11:51:52 Voltage Offset Correction: v_off_ini = 353.983 uV, v_off_fin = 350.495 uV 11:51:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 236.575 uVs 11:51:52 Integrated Voltage Measurement... 11:52:01 Voltage Offset Correction: v_off_ini = 356.531 uV, v_off_fin = 328.920 uV 11:52:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -245.674 uVs 11:52:01 Integrated Voltage Measurement... 11:52:10 Voltage Offset Correction: v_off_ini = 331.194 uV, v_off_fin = 338.530 uV 11:52:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 216.415 uVs 11:52:10 Integrated Voltage Measurement... 11:52:19 Voltage Offset Correction: v_off_ini = 350.652 uV, v_off_fin = 349.444 uV 11:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -204.111 uVs 11:52:19 Integrated Voltage Measurement... 11:52:28 Voltage Offset Correction: v_off_ini = 343.105 uV, v_off_fin = 351.054 uV 11:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 250.729 uVs 11:52:32 I1X Average and RMS of Measurements VT = -230.925 +- 2.814 uVs I1X = 46.186 +- 0.564 uTm 11:52:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:52:39 Integrated Voltage Measurement... 11:52:48 Voltage Offset Correction: v_off_ini = 341.981 uV, v_off_fin = 326.874 uV 11:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.503 uVs 11:52:48 Integrated Voltage Measurement... 11:52:57 Voltage Offset Correction: v_off_ini = 337.268 uV, v_off_fin = 346.376 uV 11:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.900 uVs 11:52:57 Integrated Voltage Measurement... 11:53:06 Voltage Offset Correction: v_off_ini = 354.150 uV, v_off_fin = 325.512 uV 11:53:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.008 uVs 11:53:06 Integrated Voltage Measurement... 11:53:15 Voltage Offset Correction: v_off_ini = 336.888 uV, v_off_fin = 351.146 uV 11:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.336 uVs 11:53:15 Integrated Voltage Measurement... 11:53:24 Voltage Offset Correction: v_off_ini = 348.022 uV, v_off_fin = 325.440 uV 11:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.264 uVs 11:53:24 Integrated Voltage Measurement... 11:53:33 Voltage Offset Correction: v_off_ini = 345.355 uV, v_off_fin = 360.186 uV 11:53:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.980 uVs 11:53:37 I1Y Average and RMS of Measurements VT = -206.999 +- 2.071 uVs I1Y = -41.397 +- 0.413 uTm 11:53:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:45 Integrated Voltage Measurement... 11:53:54 Voltage Offset Correction: v_off_ini = 339.563 uV, v_off_fin = 338.857 uV 11:53:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -255.460 uVs 11:53:54 Integrated Voltage Measurement... 11:54:03 Voltage Offset Correction: v_off_ini = 364.405 uV, v_off_fin = 378.223 uV 11:54:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 229.340 uVs 11:54:03 Integrated Voltage Measurement... 11:54:12 Voltage Offset Correction: v_off_ini = 359.097 uV, v_off_fin = 343.432 uV 11:54:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -244.615 uVs 11:54:12 Integrated Voltage Measurement... 11:54:21 Voltage Offset Correction: v_off_ini = 355.620 uV, v_off_fin = 351.938 uV 11:54:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 238.052 uVs 11:54:21 Integrated Voltage Measurement... 11:54:30 Voltage Offset Correction: v_off_ini = 353.050 uV, v_off_fin = 337.097 uV 11:54:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -225.670 uVs 11:54:30 Integrated Voltage Measurement... 11:54:39 Voltage Offset Correction: v_off_ini = 349.446 uV, v_off_fin = 374.115 uV 11:54:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 232.097 uVs 11:54:42 I2X Average and RMS of Measurements VT = -237.539 +- 6.136 uVs I2X = 21.854 +- 0.565 uTm^2 11:54:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:54:50 Integrated Voltage Measurement... 11:54:59 Voltage Offset Correction: v_off_ini = 338.985 uV, v_off_fin = 337.589 uV 11:54:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -241.832 uVs 11:54:59 Integrated Voltage Measurement... 11:55:08 Voltage Offset Correction: v_off_ini = 343.142 uV, v_off_fin = 340.118 uV 11:55:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.739 uVs 11:55:08 Integrated Voltage Measurement... 11:55:17 Voltage Offset Correction: v_off_ini = 345.243 uV, v_off_fin = 348.059 uV 11:55:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.753 uVs 11:55:17 Integrated Voltage Measurement... 11:55:26 Voltage Offset Correction: v_off_ini = 351.299 uV, v_off_fin = 358.491 uV 11:55:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.349 uVs 11:55:26 Integrated Voltage Measurement... 11:55:35 Voltage Offset Correction: v_off_ini = 336.882 uV, v_off_fin = 336.404 uV 11:55:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.426 uVs 11:55:35 Integrated Voltage Measurement... 11:55:44 Voltage Offset Correction: v_off_ini = 339.147 uV, v_off_fin = 339.630 uV 11:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.181 uVs 11:55:46 I2Y Average and RMS of Measurements VT = -243.047 +- 3.576 uVs I2Y = -22.361 +- 0.329 uTm^2 11:55:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:01 Integrated Voltage Measurement... 11:56:10 Voltage Offset Correction: v_off_ini = 358.925 uV, v_off_fin = 342.241 uV 11:56:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -233.478 uVs 11:56:10 Integrated Voltage Measurement... 11:56:19 Voltage Offset Correction: v_off_ini = 344.297 uV, v_off_fin = 349.868 uV 11:56:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 236.816 uVs 11:56:19 Integrated Voltage Measurement... 11:56:28 Voltage Offset Correction: v_off_ini = 336.249 uV, v_off_fin = 329.760 uV 11:56:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -236.563 uVs 11:56:28 Integrated Voltage Measurement... 11:56:37 Voltage Offset Correction: v_off_ini = 340.259 uV, v_off_fin = 339.251 uV 11:56:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 231.656 uVs 11:56:37 Integrated Voltage Measurement... 11:56:46 Voltage Offset Correction: v_off_ini = 340.521 uV, v_off_fin = 336.158 uV 11:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -217.740 uVs 11:56:46 Integrated Voltage Measurement... 11:56:55 Voltage Offset Correction: v_off_ini = 344.602 uV, v_off_fin = 336.730 uV 11:56:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 209.254 uVs 11:57:00 I1X Average and RMS of Measurements VT = -227.585 +- 9.970 uVs I1X = 45.517 +- 1.994 uTm 11:57:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:06 Integrated Voltage Measurement... 11:57:15 Voltage Offset Correction: v_off_ini = 332.718 uV, v_off_fin = 332.639 uV 11:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -207.965 uVs 11:57:15 Integrated Voltage Measurement... 11:57:24 Voltage Offset Correction: v_off_ini = 330.511 uV, v_off_fin = 340.295 uV 11:57:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 224.301 uVs 11:57:24 Integrated Voltage Measurement... 11:57:33 Voltage Offset Correction: v_off_ini = 335.612 uV, v_off_fin = 345.483 uV 11:57:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.472 uVs 11:57:33 Integrated Voltage Measurement... 11:57:42 Voltage Offset Correction: v_off_ini = 334.514 uV, v_off_fin = 350.606 uV 11:57:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.848 uVs 11:57:42 Integrated Voltage Measurement... 11:57:51 Voltage Offset Correction: v_off_ini = 339.216 uV, v_off_fin = 337.583 uV 11:57:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.246 uVs 11:57:51 Integrated Voltage Measurement... 11:58:00 Voltage Offset Correction: v_off_ini = 355.675 uV, v_off_fin = 369.780 uV 11:58:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.602 uVs 11:58:05 I1Y Average and RMS of Measurements VT = -213.739 +- 5.663 uVs I1Y = -42.746 +- 1.131 uTm 11:58:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:12 Integrated Voltage Measurement... 11:58:21 Voltage Offset Correction: v_off_ini = 370.994 uV, v_off_fin = 358.216 uV 11:58:21 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -272.491 uVs 11:58:21 Integrated Voltage Measurement... 11:58:30 Voltage Offset Correction: v_off_ini = 358.191 uV, v_off_fin = 359.394 uV 11:58:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 241.386 uVs 11:58:30 Integrated Voltage Measurement... 11:58:39 Voltage Offset Correction: v_off_ini = 372.315 uV, v_off_fin = 364.413 uV 11:58:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -215.788 uVs 11:58:39 Integrated Voltage Measurement... 11:58:48 Voltage Offset Correction: v_off_ini = 371.602 uV, v_off_fin = 382.508 uV 11:58:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 214.835 uVs 11:58:48 Integrated Voltage Measurement... 11:58:57 Voltage Offset Correction: v_off_ini = 369.352 uV, v_off_fin = 370.743 uV 11:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -244.629 uVs 11:58:57 Integrated Voltage Measurement... 11:59:06 Voltage Offset Correction: v_off_ini = 363.464 uV, v_off_fin = 369.641 uV 11:59:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 230.246 uVs 11:59:09 I2X Average and RMS of Measurements VT = -236.562 +- 17.005 uVs I2X = 21.764 +- 1.563 uTm^2 11:59:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:17 Integrated Voltage Measurement... 11:59:26 Voltage Offset Correction: v_off_ini = 375.490 uV, v_off_fin = 369.960 uV 11:59:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -239.165 uVs 11:59:26 Integrated Voltage Measurement... 11:59:35 Voltage Offset Correction: v_off_ini = 373.751 uV, v_off_fin = 379.376 uV 11:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.752 uVs 11:59:35 Integrated Voltage Measurement... 11:59:44 Voltage Offset Correction: v_off_ini = 373.907 uV, v_off_fin = 384.926 uV 11:59:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.191 uVs 11:59:44 Integrated Voltage Measurement... 11:59:53 Voltage Offset Correction: v_off_ini = 390.245 uV, v_off_fin = 383.054 uV 11:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.893 uVs 11:59:53 Integrated Voltage Measurement... 12:00:02 Voltage Offset Correction: v_off_ini = 393.581 uV, v_off_fin = 373.116 uV 12:00:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.405 uVs 12:00:02 Integrated Voltage Measurement... 12:00:11 Voltage Offset Correction: v_off_ini = 387.333 uV, v_off_fin = 387.942 uV 12:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.307 uVs 12:00:14 I2Y Average and RMS of Measurements VT = -245.286 +- 3.469 uVs I2Y = -22.567 +- 0.319 uTm^2 12:00:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:30 Integrated Voltage Measurement... 12:00:39 Voltage Offset Correction: v_off_ini = 383.021 uV, v_off_fin = 390.801 uV 12:00:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -225.670 uVs 12:00:39 Integrated Voltage Measurement... 12:00:48 Voltage Offset Correction: v_off_ini = 398.399 uV, v_off_fin = 386.186 uV 12:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 238.794 uVs 12:00:48 Integrated Voltage Measurement... 12:00:57 Voltage Offset Correction: v_off_ini = 393.855 uV, v_off_fin = 368.066 uV 12:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -221.625 uVs 12:00:57 Integrated Voltage Measurement... 12:01:06 Voltage Offset Correction: v_off_ini = 376.886 uV, v_off_fin = 388.399 uV 12:01:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 225.188 uVs 12:01:06 Integrated Voltage Measurement... 12:01:15 Voltage Offset Correction: v_off_ini = 390.269 uV, v_off_fin = 371.090 uV 12:01:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -223.123 uVs 12:01:15 Integrated Voltage Measurement... 12:01:24 Voltage Offset Correction: v_off_ini = 371.791 uV, v_off_fin = 382.016 uV 12:01:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 243.387 uVs 12:01:28 I1X Average and RMS of Measurements VT = -229.631 +- 4.421 uVs I1X = 45.927 +- 0.885 uTm 12:01:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:35 Integrated Voltage Measurement... 12:01:44 Voltage Offset Correction: v_off_ini = 359.755 uV, v_off_fin = 359.347 uV 12:01:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.573 uVs 12:01:44 Integrated Voltage Measurement... 12:01:53 Voltage Offset Correction: v_off_ini = 359.318 uV, v_off_fin = 374.879 uV 12:01:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.063 uVs 12:01:53 Integrated Voltage Measurement... 12:02:02 Voltage Offset Correction: v_off_ini = 364.915 uV, v_off_fin = 335.579 uV 12:02:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.678 uVs 12:02:02 Integrated Voltage Measurement... 12:02:11 Voltage Offset Correction: v_off_ini = 349.593 uV, v_off_fin = 374.401 uV 12:02:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.713 uVs 12:02:11 Integrated Voltage Measurement... 12:02:20 Voltage Offset Correction: v_off_ini = 356.987 uV, v_off_fin = 339.231 uV 12:02:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.335 uVs 12:02:20 Integrated Voltage Measurement... 12:02:29 Voltage Offset Correction: v_off_ini = 358.401 uV, v_off_fin = 350.858 uV 12:02:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.299 uVs 12:02:33 I1Y Average and RMS of Measurements VT = -209.944 +- 9.019 uVs I1Y = -41.988 +- 1.804 uTm 12:02:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:41 Integrated Voltage Measurement... 12:02:49 Voltage Offset Correction: v_off_ini = 352.326 uV, v_off_fin = 353.001 uV 12:02:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -238.244 uVs 12:02:50 Integrated Voltage Measurement... 12:02:59 Voltage Offset Correction: v_off_ini = 350.693 uV, v_off_fin = 365.560 uV 12:02:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 233.668 uVs 12:02:59 Integrated Voltage Measurement... 12:03:08 Voltage Offset Correction: v_off_ini = 361.368 uV, v_off_fin = 340.793 uV 12:03:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -241.884 uVs 12:03:08 Integrated Voltage Measurement... 12:03:17 Voltage Offset Correction: v_off_ini = 366.537 uV, v_off_fin = 344.811 uV 12:03:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 226.248 uVs 12:03:17 Integrated Voltage Measurement... 12:03:26 Voltage Offset Correction: v_off_ini = 358.051 uV, v_off_fin = 338.799 uV 12:03:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -237.255 uVs 12:03:26 Integrated Voltage Measurement... 12:03:35 Voltage Offset Correction: v_off_ini = 352.219 uV, v_off_fin = 366.546 uV 12:03:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 244.677 uVs 12:03:37 I2X Average and RMS of Measurements VT = -236.996 +- 2.911 uVs I2X = 21.804 +- 0.269 uTm^2 12:03:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:45 Integrated Voltage Measurement... 12:03:54 Voltage Offset Correction: v_off_ini = 353.410 uV, v_off_fin = 344.592 uV 12:03:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -236.341 uVs 12:03:54 Integrated Voltage Measurement... 12:04:03 Voltage Offset Correction: v_off_ini = 352.574 uV, v_off_fin = 347.834 uV 12:04:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 262.749 uVs 12:04:03 Integrated Voltage Measurement... 12:04:12 Voltage Offset Correction: v_off_ini = 359.358 uV, v_off_fin = 338.257 uV 12:04:12 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -249.517 uVs 12:04:12 Integrated Voltage Measurement... 12:04:21 Voltage Offset Correction: v_off_ini = 355.409 uV, v_off_fin = 348.652 uV 12:04:21 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 261.673 uVs 12:04:21 Integrated Voltage Measurement... 12:04:30 Voltage Offset Correction: v_off_ini = 362.482 uV, v_off_fin = 355.468 uV 12:04:30 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -243.874 uVs 12:04:30 Integrated Voltage Measurement... 12:04:39 Voltage Offset Correction: v_off_ini = 359.325 uV, v_off_fin = 358.234 uV 12:04:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 240.401 uVs 12:04:41 I2Y Average and RMS of Measurements VT = -249.092 +- 5.503 uVs I2Y = -22.915 +- 0.506 uTm^2 12:04:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:57 Integrated Voltage Measurement... 12:05:06 Voltage Offset Correction: v_off_ini = 385.752 uV, v_off_fin = 359.953 uV 12:05:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -243.467 uVs 12:05:06 Integrated Voltage Measurement... 12:05:15 Voltage Offset Correction: v_off_ini = 371.636 uV, v_off_fin = 366.656 uV 12:05:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 215.640 uVs 12:05:15 Integrated Voltage Measurement... 12:05:24 Voltage Offset Correction: v_off_ini = 360.830 uV, v_off_fin = 366.792 uV 12:05:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -220.510 uVs 12:05:24 Integrated Voltage Measurement... 12:05:33 Voltage Offset Correction: v_off_ini = 356.858 uV, v_off_fin = 357.243 uV 12:05:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 234.835 uVs 12:05:33 Integrated Voltage Measurement... 12:05:42 Voltage Offset Correction: v_off_ini = 363.656 uV, v_off_fin = 356.822 uV 12:05:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -230.129 uVs 12:05:42 Integrated Voltage Measurement... 12:05:51 Voltage Offset Correction: v_off_ini = 366.780 uV, v_off_fin = 354.442 uV 12:05:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 225.183 uVs 12:05:56 I1X Average and RMS of Measurements VT = -228.294 +- 0.891 uVs I1X = 45.660 +- 0.178 uTm 12:05:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:02 Integrated Voltage Measurement... 12:06:11 Voltage Offset Correction: v_off_ini = 361.425 uV, v_off_fin = 344.922 uV 12:06:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.412 uVs 12:06:11 Integrated Voltage Measurement... 12:06:20 Voltage Offset Correction: v_off_ini = 362.188 uV, v_off_fin = 379.575 uV 12:06:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.568 uVs 12:06:20 Integrated Voltage Measurement... 12:06:29 Voltage Offset Correction: v_off_ini = 388.746 uV, v_off_fin = 363.737 uV 12:06:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.673 uVs 12:06:29 Integrated Voltage Measurement... 12:06:38 Voltage Offset Correction: v_off_ini = 360.296 uV, v_off_fin = 361.241 uV 12:06:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.526 uVs 12:06:38 Integrated Voltage Measurement... 12:06:47 Voltage Offset Correction: v_off_ini = 353.795 uV, v_off_fin = 342.871 uV 12:06:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.860 uVs 12:06:47 Integrated Voltage Measurement... 12:06:56 Voltage Offset Correction: v_off_ini = 349.236 uV, v_off_fin = 386.984 uV 12:06:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.025 uVs 12:07:00 I1Y Average and RMS of Measurements VT = -208.844 +- 5.973 uVs I1Y = -41.765 +- 1.195 uTm 12:07:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:08 Integrated Voltage Measurement... 12:07:17 Voltage Offset Correction: v_off_ini = 354.875 uV, v_off_fin = 342.911 uV 12:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -233.339 uVs 12:07:17 Integrated Voltage Measurement... 12:07:26 Voltage Offset Correction: v_off_ini = 356.134 uV, v_off_fin = 346.138 uV 12:07:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 235.851 uVs 12:07:26 Integrated Voltage Measurement... 12:07:35 Voltage Offset Correction: v_off_ini = 338.200 uV, v_off_fin = 333.231 uV 12:07:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -252.202 uVs 12:07:35 Integrated Voltage Measurement... 12:07:44 Voltage Offset Correction: v_off_ini = 350.009 uV, v_off_fin = 354.642 uV 12:07:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 240.997 uVs 12:07:44 Integrated Voltage Measurement... 12:07:53 Voltage Offset Correction: v_off_ini = 340.084 uV, v_off_fin = 339.874 uV 12:07:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -238.071 uVs 12:07:53 Integrated Voltage Measurement... 12:08:02 Voltage Offset Correction: v_off_ini = 346.798 uV, v_off_fin = 361.784 uV 12:08:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 210.632 uVs 12:08:05 I2X Average and RMS of Measurements VT = -235.182 +- 9.092 uVs I2X = 21.637 +- 0.836 uTm^2 12:08:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:12 Integrated Voltage Measurement... 12:08:21 Voltage Offset Correction: v_off_ini = 327.002 uV, v_off_fin = 348.697 uV 12:08:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -232.124 uVs 12:08:21 Integrated Voltage Measurement... 12:08:30 Voltage Offset Correction: v_off_ini = 334.887 uV, v_off_fin = 346.684 uV 12:08:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.919 uVs 12:08:30 Integrated Voltage Measurement... 12:08:39 Voltage Offset Correction: v_off_ini = 335.299 uV, v_off_fin = 336.520 uV 12:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.689 uVs 12:08:39 Integrated Voltage Measurement... 12:08:48 Voltage Offset Correction: v_off_ini = 338.820 uV, v_off_fin = 341.102 uV 12:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.810 uVs 12:08:48 Integrated Voltage Measurement... 12:08:57 Voltage Offset Correction: v_off_ini = 334.974 uV, v_off_fin = 338.793 uV 12:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.882 uVs 12:08:58 Integrated Voltage Measurement... 12:09:06 Voltage Offset Correction: v_off_ini = 333.166 uV, v_off_fin = 335.871 uV 12:09:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.916 uVs 12:09:09 I2Y Average and RMS of Measurements VT = -231.890 +- 7.589 uVs I2Y = -21.334 +- 0.698 uTm^2 12:09:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:27 Integrated Voltage Measurement... 12:09:36 Voltage Offset Correction: v_off_ini = 339.380 uV, v_off_fin = 339.464 uV 12:09:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -216.669 uVs 12:09:36 Integrated Voltage Measurement... 12:09:45 Voltage Offset Correction: v_off_ini = 328.687 uV, v_off_fin = 353.000 uV 12:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.411 uVs 12:09:45 Integrated Voltage Measurement... 12:09:54 Voltage Offset Correction: v_off_ini = 349.018 uV, v_off_fin = 349.728 uV 12:09:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -212.114 uVs 12:09:54 Integrated Voltage Measurement... 12:10:03 Voltage Offset Correction: v_off_ini = 339.647 uV, v_off_fin = 342.295 uV 12:10:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 226.608 uVs 12:10:03 Integrated Voltage Measurement... 12:10:12 Voltage Offset Correction: v_off_ini = 336.258 uV, v_off_fin = 316.033 uV 12:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -206.966 uVs 12:10:12 Integrated Voltage Measurement... 12:10:21 Voltage Offset Correction: v_off_ini = 319.241 uV, v_off_fin = 308.631 uV 12:10:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 206.253 uVs 12:10:25 I1X Average and RMS of Measurements VT = -210.337 +- 6.413 uVs I1X = 42.070 +- 1.281 uTm 12:10:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:32 Integrated Voltage Measurement... 12:10:41 Voltage Offset Correction: v_off_ini = 342.312 uV, v_off_fin = 319.240 uV 12:10:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.578 uVs 12:10:41 Integrated Voltage Measurement... 12:10:50 Voltage Offset Correction: v_off_ini = 314.331 uV, v_off_fin = 342.375 uV 12:10:50 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 219.873 uVs 12:10:50 Integrated Voltage Measurement... 12:10:59 Voltage Offset Correction: v_off_ini = 331.305 uV, v_off_fin = 314.341 uV 12:10:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.469 uVs 12:10:59 Integrated Voltage Measurement... 12:11:08 Voltage Offset Correction: v_off_ini = 339.183 uV, v_off_fin = 341.460 uV 12:11:08 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 209.334 uVs 12:11:08 Integrated Voltage Measurement... 12:11:17 Voltage Offset Correction: v_off_ini = 328.832 uV, v_off_fin = 314.038 uV 12:11:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.826 uVs 12:11:17 Integrated Voltage Measurement... 12:11:26 Voltage Offset Correction: v_off_ini = 341.105 uV, v_off_fin = 364.835 uV 12:11:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 206.476 uVs 12:11:30 I1Y Average and RMS of Measurements VT = -205.593 +- 4.615 uVs I1Y = -41.112 +- 0.922 uTm 12:11:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:38 Integrated Voltage Measurement... 12:11:47 Voltage Offset Correction: v_off_ini = 333.053 uV, v_off_fin = 341.478 uV 12:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -187.747 uVs 12:11:47 Integrated Voltage Measurement... 12:11:56 Voltage Offset Correction: v_off_ini = 343.654 uV, v_off_fin = 346.647 uV 12:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 220.237 uVs 12:11:56 Integrated Voltage Measurement... 12:12:05 Voltage Offset Correction: v_off_ini = 348.419 uV, v_off_fin = 334.505 uV 12:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -224.037 uVs 12:12:05 Integrated Voltage Measurement... 12:12:14 Voltage Offset Correction: v_off_ini = 348.129 uV, v_off_fin = 346.382 uV 12:12:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 220.270 uVs 12:12:14 Integrated Voltage Measurement... 12:12:23 Voltage Offset Correction: v_off_ini = 349.944 uV, v_off_fin = 347.781 uV 12:12:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -234.567 uVs 12:12:23 Integrated Voltage Measurement... 12:12:32 Voltage Offset Correction: v_off_ini = 347.996 uV, v_off_fin = 356.338 uV 12:12:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 211.687 uVs 12:12:35 I2X Average and RMS of Measurements VT = -216.424 +- 8.800 uVs I2X = 19.911 +- 0.810 uTm^2 12:12:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:42 Integrated Voltage Measurement... 12:12:51 Voltage Offset Correction: v_off_ini = 351.470 uV, v_off_fin = 350.700 uV 12:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.941 uVs 12:12:51 Integrated Voltage Measurement... 12:13:00 Voltage Offset Correction: v_off_ini = 343.774 uV, v_off_fin = 338.728 uV 12:13:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.960 uVs 12:13:00 Integrated Voltage Measurement... 12:13:09 Voltage Offset Correction: v_off_ini = 335.145 uV, v_off_fin = 345.963 uV 12:13:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.816 uVs 12:13:09 Integrated Voltage Measurement... 12:13:18 Voltage Offset Correction: v_off_ini = 338.658 uV, v_off_fin = 345.711 uV 12:13:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.505 uVs 12:13:18 Integrated Voltage Measurement... 12:13:27 Voltage Offset Correction: v_off_ini = 343.523 uV, v_off_fin = 334.762 uV 12:13:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.564 uVs 12:13:27 Integrated Voltage Measurement... 12:13:36 Voltage Offset Correction: v_off_ini = 352.676 uV, v_off_fin = 355.127 uV 12:13:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.755 uVs 12:13:39 I2Y Average and RMS of Measurements VT = -230.257 +- 5.727 uVs I2Y = -21.184 +- 0.527 uTm^2 12:13:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:57 Integrated Voltage Measurement... 12:14:06 Voltage Offset Correction: v_off_ini = 354.059 uV, v_off_fin = 355.287 uV 12:14:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -188.372 uVs 12:14:06 Integrated Voltage Measurement... 12:14:15 Voltage Offset Correction: v_off_ini = 350.762 uV, v_off_fin = 365.243 uV 12:14:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.152 uVs 12:14:15 Integrated Voltage Measurement... 12:14:24 Voltage Offset Correction: v_off_ini = 365.808 uV, v_off_fin = 362.387 uV 12:14:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -182.077 uVs 12:14:24 Integrated Voltage Measurement... 12:14:33 Voltage Offset Correction: v_off_ini = 363.726 uV, v_off_fin = 352.358 uV 12:14:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 207.908 uVs 12:14:33 Integrated Voltage Measurement... 12:14:42 Voltage Offset Correction: v_off_ini = 368.634 uV, v_off_fin = 353.549 uV 12:14:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -171.331 uVs 12:14:42 Integrated Voltage Measurement... 12:14:51 Voltage Offset Correction: v_off_ini = 375.003 uV, v_off_fin = 355.345 uV 12:14:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.503 uVs 12:14:55 I1X Average and RMS of Measurements VT = -185.724 +- 8.789 uVs I1X = 37.148 +- 1.758 uTm 12:14:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:02 Integrated Voltage Measurement... 12:15:11 Voltage Offset Correction: v_off_ini = 369.275 uV, v_off_fin = 370.349 uV 12:15:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.007 uVs 12:15:11 Integrated Voltage Measurement... 12:15:20 Voltage Offset Correction: v_off_ini = 371.849 uV, v_off_fin = 375.159 uV 12:15:20 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 189.322 uVs 12:15:20 Integrated Voltage Measurement... 12:15:29 Voltage Offset Correction: v_off_ini = 353.747 uV, v_off_fin = 356.785 uV 12:15:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.580 uVs 12:15:29 Integrated Voltage Measurement... 12:15:38 Voltage Offset Correction: v_off_ini = 356.621 uV, v_off_fin = 366.270 uV 12:15:38 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.461 uVs 12:15:38 Integrated Voltage Measurement... 12:15:47 Voltage Offset Correction: v_off_ini = 368.276 uV, v_off_fin = 353.042 uV 12:15:47 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -198.903 uVs 12:15:47 Integrated Voltage Measurement... 12:15:56 Voltage Offset Correction: v_off_ini = 355.094 uV, v_off_fin = 367.994 uV 12:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.653 uVs 12:16:00 I1Y Average and RMS of Measurements VT = -191.488 +- 6.817 uVs I1Y = -38.294 +- 1.363 uTm 12:16:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:16:08 Integrated Voltage Measurement... 12:16:17 Voltage Offset Correction: v_off_ini = 368.533 uV, v_off_fin = 360.663 uV 12:16:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -207.226 uVs 12:16:17 Integrated Voltage Measurement... 12:16:26 Voltage Offset Correction: v_off_ini = 359.264 uV, v_off_fin = 362.079 uV 12:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.136 uVs 12:16:26 Integrated Voltage Measurement... 12:16:35 Voltage Offset Correction: v_off_ini = 354.782 uV, v_off_fin = 355.416 uV 12:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -195.088 uVs 12:16:35 Integrated Voltage Measurement... 12:16:44 Voltage Offset Correction: v_off_ini = 331.275 uV, v_off_fin = 355.644 uV 12:16:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 209.160 uVs 12:16:44 Integrated Voltage Measurement... 12:16:53 Voltage Offset Correction: v_off_ini = 350.532 uV, v_off_fin = 334.641 uV 12:16:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -191.065 uVs 12:16:53 Integrated Voltage Measurement... 12:17:02 Voltage Offset Correction: v_off_ini = 334.020 uV, v_off_fin = 346.325 uV 12:17:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 192.477 uVs 12:17:05 I2X Average and RMS of Measurements VT = -197.025 +- 4.228 uVs I2X = 18.126 +- 0.389 uTm^2 12:17:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:17:12 Integrated Voltage Measurement... 12:17:21 Voltage Offset Correction: v_off_ini = 345.780 uV, v_off_fin = 361.505 uV 12:17:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.729 uVs 12:17:21 Integrated Voltage Measurement... 12:17:30 Voltage Offset Correction: v_off_ini = 350.341 uV, v_off_fin = 330.016 uV 12:17:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.586 uVs 12:17:30 Integrated Voltage Measurement... 12:17:39 Voltage Offset Correction: v_off_ini = 330.371 uV, v_off_fin = 339.227 uV 12:17:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.590 uVs 12:17:39 Integrated Voltage Measurement... 12:17:48 Voltage Offset Correction: v_off_ini = 342.180 uV, v_off_fin = 351.350 uV 12:17:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.878 uVs 12:17:48 Integrated Voltage Measurement... 12:17:57 Voltage Offset Correction: v_off_ini = 344.298 uV, v_off_fin = 332.252 uV 12:17:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.496 uVs 12:17:57 Integrated Voltage Measurement... 12:18:06 Voltage Offset Correction: v_off_ini = 336.395 uV, v_off_fin = 345.656 uV 12:18:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.905 uVs 12:18:09 I2Y Average and RMS of Measurements VT = -215.864 +- 5.642 uVs I2Y = -19.860 +- 0.519 uTm^2 12:18:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:27 Integrated Voltage Measurement... 12:18:36 Voltage Offset Correction: v_off_ini = 350.251 uV, v_off_fin = 343.546 uV 12:18:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -160.609 uVs 12:18:36 Integrated Voltage Measurement... 12:18:45 Voltage Offset Correction: v_off_ini = 343.502 uV, v_off_fin = 353.641 uV 12:18:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.515 uVs 12:18:45 Integrated Voltage Measurement... 12:18:54 Voltage Offset Correction: v_off_ini = 345.623 uV, v_off_fin = 336.306 uV 12:18:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.487 uVs 12:18:54 Integrated Voltage Measurement... 12:19:03 Voltage Offset Correction: v_off_ini = 337.554 uV, v_off_fin = 340.262 uV 12:19:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.113 uVs 12:19:03 Integrated Voltage Measurement... 12:19:12 Voltage Offset Correction: v_off_ini = 344.519 uV, v_off_fin = 340.890 uV 12:19:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.816 uVs 12:19:12 Integrated Voltage Measurement... 12:19:21 Voltage Offset Correction: v_off_ini = 340.111 uV, v_off_fin = 331.709 uV 12:19:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.909 uVs 12:19:25 I1X Average and RMS of Measurements VT = -159.741 +- 4.526 uVs I1X = 31.950 +- 0.903 uTm 12:19:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:32 Integrated Voltage Measurement... 12:19:41 Voltage Offset Correction: v_off_ini = 334.198 uV, v_off_fin = 299.639 uV 12:19:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -198.108 uVs 12:19:41 Integrated Voltage Measurement... 12:19:50 Voltage Offset Correction: v_off_ini = 311.586 uV, v_off_fin = 330.107 uV 12:19:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.695 uVs 12:19:50 Integrated Voltage Measurement... 12:19:59 Voltage Offset Correction: v_off_ini = 320.746 uV, v_off_fin = 305.814 uV 12:19:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.899 uVs 12:19:59 Integrated Voltage Measurement... 12:20:08 Voltage Offset Correction: v_off_ini = 313.569 uV, v_off_fin = 325.701 uV 12:20:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.188 uVs 12:20:08 Integrated Voltage Measurement... 12:20:17 Voltage Offset Correction: v_off_ini = 305.726 uV, v_off_fin = 296.072 uV 12:20:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.210 uVs 12:20:17 Integrated Voltage Measurement... 12:20:26 Voltage Offset Correction: v_off_ini = 321.369 uV, v_off_fin = 334.571 uV 12:20:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 194.101 uVs 12:20:30 I1Y Average and RMS of Measurements VT = -193.367 +- 2.197 uVs I1Y = -38.668 +- 0.438 uTm 12:20:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:38 Integrated Voltage Measurement... 12:20:47 Voltage Offset Correction: v_off_ini = 322.478 uV, v_off_fin = 316.762 uV 12:20:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -165.152 uVs 12:20:47 Integrated Voltage Measurement... 12:20:56 Voltage Offset Correction: v_off_ini = 332.032 uV, v_off_fin = 315.834 uV 12:20:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 179.351 uVs 12:20:56 Integrated Voltage Measurement... 12:21:05 Voltage Offset Correction: v_off_ini = 339.688 uV, v_off_fin = 316.705 uV 12:21:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -169.127 uVs 12:21:05 Integrated Voltage Measurement... 12:21:14 Voltage Offset Correction: v_off_ini = 332.507 uV, v_off_fin = 341.855 uV 12:21:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 164.571 uVs 12:21:14 Integrated Voltage Measurement... 12:21:23 Voltage Offset Correction: v_off_ini = 341.798 uV, v_off_fin = 322.970 uV 12:21:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -175.692 uVs 12:21:23 Integrated Voltage Measurement... 12:21:32 Voltage Offset Correction: v_off_ini = 326.880 uV, v_off_fin = 345.421 uV 12:21:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 180.286 uVs 12:21:35 I2X Average and RMS of Measurements VT = -172.363 +- 4.548 uVs I2X = 15.857 +- 0.418 uTm^2 12:21:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:43 Integrated Voltage Measurement... 12:21:51 Voltage Offset Correction: v_off_ini = 326.410 uV, v_off_fin = 332.215 uV 12:21:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.285 uVs 12:21:52 Integrated Voltage Measurement... 12:22:01 Voltage Offset Correction: v_off_ini = 321.861 uV, v_off_fin = 320.424 uV 12:22:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.050 uVs 12:22:01 Integrated Voltage Measurement... 12:22:10 Voltage Offset Correction: v_off_ini = 334.023 uV, v_off_fin = 321.354 uV 12:22:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.990 uVs 12:22:10 Integrated Voltage Measurement... 12:22:19 Voltage Offset Correction: v_off_ini = 318.618 uV, v_off_fin = 330.110 uV 12:22:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.035 uVs 12:22:19 Integrated Voltage Measurement... 12:22:28 Voltage Offset Correction: v_off_ini = 333.276 uV, v_off_fin = 336.746 uV 12:22:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.962 uVs 12:22:28 Integrated Voltage Measurement... 12:22:37 Voltage Offset Correction: v_off_ini = 336.711 uV, v_off_fin = 338.830 uV 12:22:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.716 uVs 12:22:39 I2Y Average and RMS of Measurements VT = -219.673 +- 4.485 uVs I2Y = -20.210 +- 0.413 uTm^2 12:22:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:57 Integrated Voltage Measurement... 12:23:06 Voltage Offset Correction: v_off_ini = 338.426 uV, v_off_fin = 329.453 uV 12:23:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -169.215 uVs 12:23:06 Integrated Voltage Measurement... 12:23:15 Voltage Offset Correction: v_off_ini = 346.843 uV, v_off_fin = 345.067 uV 12:23:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.432 uVs 12:23:15 Integrated Voltage Measurement... 12:23:24 Voltage Offset Correction: v_off_ini = 364.712 uV, v_off_fin = 371.107 uV 12:23:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.764 uVs 12:23:25 Integrated Voltage Measurement... 12:23:33 Voltage Offset Correction: v_off_ini = 372.703 uV, v_off_fin = 375.935 uV 12:23:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.160 uVs 12:23:34 Integrated Voltage Measurement... 12:23:43 Voltage Offset Correction: v_off_ini = 360.879 uV, v_off_fin = 375.321 uV 12:23:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.545 uVs 12:23:43 Integrated Voltage Measurement... 12:23:52 Voltage Offset Correction: v_off_ini = 348.118 uV, v_off_fin = 365.144 uV 12:23:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.056 uVs 12:23:56 I1X Average and RMS of Measurements VT = -153.695 +- 1.730 uVs I1X = 30.740 +- 0.346 uTm 12:23:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:03 Integrated Voltage Measurement... 12:24:12 Voltage Offset Correction: v_off_ini = 366.062 uV, v_off_fin = 367.308 uV 12:24:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -175.747 uVs 12:24:12 Integrated Voltage Measurement... 12:24:21 Voltage Offset Correction: v_off_ini = 372.695 uV, v_off_fin = 379.633 uV 12:24:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.872 uVs 12:24:21 Integrated Voltage Measurement... 12:24:30 Voltage Offset Correction: v_off_ini = 365.948 uV, v_off_fin = 360.586 uV 12:24:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.348 uVs 12:24:30 Integrated Voltage Measurement... 12:24:39 Voltage Offset Correction: v_off_ini = 362.374 uV, v_off_fin = 367.927 uV 12:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.549 uVs 12:24:39 Integrated Voltage Measurement... 12:24:48 Voltage Offset Correction: v_off_ini = 360.554 uV, v_off_fin = 362.782 uV 12:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.022 uVs 12:24:48 Integrated Voltage Measurement... 12:24:57 Voltage Offset Correction: v_off_ini = 372.043 uV, v_off_fin = 373.434 uV 12:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.161 uVs 12:25:01 I1Y Average and RMS of Measurements VT = -184.616 +- 4.842 uVs I1Y = -36.924 +- 0.969 uTm 12:25:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:09 Integrated Voltage Measurement... 12:25:18 Voltage Offset Correction: v_off_ini = 368.030 uV, v_off_fin = 379.313 uV 12:25:18 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -117.043 uVs 12:25:18 Integrated Voltage Measurement... 12:25:27 Voltage Offset Correction: v_off_ini = 382.753 uV, v_off_fin = 398.531 uV 12:25:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.912 uVs 12:25:27 Integrated Voltage Measurement... 12:25:36 Voltage Offset Correction: v_off_ini = 389.125 uV, v_off_fin = 362.236 uV 12:25:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.747 uVs 12:25:36 Integrated Voltage Measurement... 12:25:45 Voltage Offset Correction: v_off_ini = 381.570 uV, v_off_fin = 382.493 uV 12:25:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.358 uVs 12:25:45 Integrated Voltage Measurement... 12:25:54 Voltage Offset Correction: v_off_ini = 380.980 uV, v_off_fin = 380.855 uV 12:25:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.243 uVs 12:25:54 Integrated Voltage Measurement... 12:26:03 Voltage Offset Correction: v_off_ini = 391.433 uV, v_off_fin = 395.390 uV 12:26:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.779 uVs 12:26:05 I2X Average and RMS of Measurements VT = -147.180 +- 8.183 uVs I2X = 13.540 +- 0.753 uTm^2 12:26:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:26:13 Integrated Voltage Measurement... 12:26:22 Voltage Offset Correction: v_off_ini = 370.762 uV, v_off_fin = 375.811 uV 12:26:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.204 uVs 12:26:22 Integrated Voltage Measurement... 12:26:31 Voltage Offset Correction: v_off_ini = 370.020 uV, v_off_fin = 383.327 uV 12:26:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.388 uVs 12:26:31 Integrated Voltage Measurement... 12:26:40 Voltage Offset Correction: v_off_ini = 369.352 uV, v_off_fin = 375.151 uV 12:26:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.067 uVs 12:26:40 Integrated Voltage Measurement... 12:26:49 Voltage Offset Correction: v_off_ini = 382.016 uV, v_off_fin = 367.939 uV 12:26:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.975 uVs 12:26:49 Integrated Voltage Measurement... 12:26:58 Voltage Offset Correction: v_off_ini = 366.101 uV, v_off_fin = 369.052 uV 12:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.537 uVs 12:26:58 Integrated Voltage Measurement... 12:27:07 Voltage Offset Correction: v_off_ini = 384.096 uV, v_off_fin = 377.364 uV 12:27:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.383 uVs 12:27:09 I2Y Average and RMS of Measurements VT = -204.592 +- 3.909 uVs I2Y = -18.822 +- 0.360 uTm^2 12:27:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:29 Integrated Voltage Measurement... 12:27:37 Voltage Offset Correction: v_off_ini = 374.867 uV, v_off_fin = 387.604 uV 12:27:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.100 uVs 12:27:38 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = 375.540 uV, v_off_fin = 373.681 uV 12:27:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.996 uVs 12:27:47 Integrated Voltage Measurement... 12:27:56 Voltage Offset Correction: v_off_ini = 365.237 uV, v_off_fin = 373.925 uV 12:27:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.954 uVs 12:27:56 Integrated Voltage Measurement... 12:28:05 Voltage Offset Correction: v_off_ini = 368.019 uV, v_off_fin = 380.351 uV 12:28:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.535 uVs 12:28:05 Integrated Voltage Measurement... 12:28:14 Voltage Offset Correction: v_off_ini = 369.703 uV, v_off_fin = 371.133 uV 12:28:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.810 uVs 12:28:14 Integrated Voltage Measurement... 12:28:23 Voltage Offset Correction: v_off_ini = 365.976 uV, v_off_fin = 375.097 uV 12:28:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.878 uVs 12:28:27 I1X Average and RMS of Measurements VT = -133.046 +- 6.938 uVs I1X = 26.610 +- 1.389 uTm 12:28:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:34 Integrated Voltage Measurement... 12:28:43 Voltage Offset Correction: v_off_ini = 367.288 uV, v_off_fin = 369.908 uV 12:28:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.943 uVs 12:28:43 Integrated Voltage Measurement... 12:28:52 Voltage Offset Correction: v_off_ini = 372.761 uV, v_off_fin = 379.193 uV 12:28:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.410 uVs 12:28:52 Integrated Voltage Measurement... 12:29:01 Voltage Offset Correction: v_off_ini = 362.634 uV, v_off_fin = 356.601 uV 12:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.907 uVs 12:29:01 Integrated Voltage Measurement... 12:29:10 Voltage Offset Correction: v_off_ini = 358.147 uV, v_off_fin = 382.363 uV 12:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.767 uVs 12:29:10 Integrated Voltage Measurement... 12:29:19 Voltage Offset Correction: v_off_ini = 338.042 uV, v_off_fin = 350.456 uV 12:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.543 uVs 12:29:19 Integrated Voltage Measurement... 12:29:28 Voltage Offset Correction: v_off_ini = 365.254 uV, v_off_fin = 368.853 uV 12:29:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.765 uVs 12:29:32 I1Y Average and RMS of Measurements VT = -177.223 +- 5.180 uVs I1Y = -35.444 +- 1.036 uTm 12:29:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:40 Integrated Voltage Measurement... 12:29:49 Voltage Offset Correction: v_off_ini = 350.569 uV, v_off_fin = 364.127 uV 12:29:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.690 uVs 12:29:49 Integrated Voltage Measurement... 12:29:58 Voltage Offset Correction: v_off_ini = 369.096 uV, v_off_fin = 378.488 uV 12:29:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.634 uVs 12:29:58 Integrated Voltage Measurement... 12:30:07 Voltage Offset Correction: v_off_ini = 354.414 uV, v_off_fin = 345.263 uV 12:30:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.799 uVs 12:30:07 Integrated Voltage Measurement... 12:30:16 Voltage Offset Correction: v_off_ini = 375.512 uV, v_off_fin = 375.992 uV 12:30:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.464 uVs 12:30:16 Integrated Voltage Measurement... 12:30:25 Voltage Offset Correction: v_off_ini = 371.722 uV, v_off_fin = 358.148 uV 12:30:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.463 uVs 12:30:25 Integrated Voltage Measurement... 12:30:34 Voltage Offset Correction: v_off_ini = 368.709 uV, v_off_fin = 374.387 uV 12:30:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.870 uVs 12:30:36 I2X Average and RMS of Measurements VT = -133.653 +- 10.423 uVs I2X = 12.296 +- 0.959 uTm^2 12:30:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:44 Integrated Voltage Measurement... 12:30:53 Voltage Offset Correction: v_off_ini = 358.537 uV, v_off_fin = 340.643 uV 12:30:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.230 uVs 12:30:53 Integrated Voltage Measurement... 12:31:02 Voltage Offset Correction: v_off_ini = 365.106 uV, v_off_fin = 348.040 uV 12:31:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.322 uVs 12:31:02 Integrated Voltage Measurement... 12:31:11 Voltage Offset Correction: v_off_ini = 357.678 uV, v_off_fin = 346.227 uV 12:31:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.940 uVs 12:31:11 Integrated Voltage Measurement... 12:31:20 Voltage Offset Correction: v_off_ini = 359.074 uV, v_off_fin = 357.554 uV 12:31:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.859 uVs 12:31:20 Integrated Voltage Measurement... 12:31:29 Voltage Offset Correction: v_off_ini = 364.512 uV, v_off_fin = 361.882 uV 12:31:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.663 uVs 12:31:29 Integrated Voltage Measurement... 12:31:38 Voltage Offset Correction: v_off_ini = 387.787 uV, v_off_fin = 385.271 uV 12:31:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.560 uVs 12:31:41 I2Y Average and RMS of Measurements VT = -197.596 +- 4.077 uVs I2Y = -18.179 +- 0.375 uTm^2 12:31:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:59 Integrated Voltage Measurement... 12:32:08 Voltage Offset Correction: v_off_ini = 368.400 uV, v_off_fin = 360.264 uV 12:32:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.327 uVs 12:32:08 Integrated Voltage Measurement... 12:32:17 Voltage Offset Correction: v_off_ini = 358.568 uV, v_off_fin = 361.691 uV 12:32:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.907 uVs 12:32:17 Integrated Voltage Measurement... 12:32:26 Voltage Offset Correction: v_off_ini = 369.270 uV, v_off_fin = 358.909 uV 12:32:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.421 uVs 12:32:26 Integrated Voltage Measurement... 12:32:35 Voltage Offset Correction: v_off_ini = 376.557 uV, v_off_fin = 369.230 uV 12:32:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.767 uVs 12:32:35 Integrated Voltage Measurement... 12:32:44 Voltage Offset Correction: v_off_ini = 371.114 uV, v_off_fin = 376.539 uV 12:32:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.209 uVs 12:32:44 Integrated Voltage Measurement... 12:32:53 Voltage Offset Correction: v_off_ini = 379.391 uV, v_off_fin = 396.283 uV 12:32:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.834 uVs 12:32:57 I1X Average and RMS of Measurements VT = -112.911 +- 9.425 uVs I1X = 22.583 +- 1.885 uTm 12:33:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:33:04 Integrated Voltage Measurement... 12:33:13 Voltage Offset Correction: v_off_ini = 379.048 uV, v_off_fin = 361.459 uV 12:33:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -168.067 uVs 12:33:13 Integrated Voltage Measurement... 12:33:22 Voltage Offset Correction: v_off_ini = 363.011 uV, v_off_fin = 387.590 uV 12:33:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.081 uVs 12:33:22 Integrated Voltage Measurement... 12:33:31 Voltage Offset Correction: v_off_ini = 373.485 uV, v_off_fin = 375.564 uV 12:33:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.827 uVs 12:33:31 Integrated Voltage Measurement... 12:33:40 Voltage Offset Correction: v_off_ini = 382.396 uV, v_off_fin = 402.995 uV 12:33:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.926 uVs 12:33:40 Integrated Voltage Measurement... 12:33:49 Voltage Offset Correction: v_off_ini = 391.871 uV, v_off_fin = 392.214 uV 12:33:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.879 uVs 12:33:49 Integrated Voltage Measurement... 12:33:58 Voltage Offset Correction: v_off_ini = 387.982 uV, v_off_fin = 393.293 uV 12:33:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.679 uVs 12:34:02 I1Y Average and RMS of Measurements VT = -180.410 +- 2.055 uVs I1Y = -36.078 +- 0.411 uTm 12:34:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:10 Integrated Voltage Measurement... 12:34:19 Voltage Offset Correction: v_off_ini = 381.839 uV, v_off_fin = 381.205 uV 12:34:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.153 uVs 12:34:19 Integrated Voltage Measurement... 12:34:28 Voltage Offset Correction: v_off_ini = 381.945 uV, v_off_fin = 406.783 uV 12:34:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.376 uVs 12:34:28 Integrated Voltage Measurement... 12:34:37 Voltage Offset Correction: v_off_ini = 403.927 uV, v_off_fin = 381.882 uV 12:34:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.661 uVs 12:34:37 Integrated Voltage Measurement... 12:34:46 Voltage Offset Correction: v_off_ini = 396.634 uV, v_off_fin = 403.994 uV 12:34:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.654 uVs 12:34:46 Integrated Voltage Measurement... 12:34:55 Voltage Offset Correction: v_off_ini = 393.696 uV, v_off_fin = 386.811 uV 12:34:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.527 uVs 12:34:55 Integrated Voltage Measurement... 12:35:04 Voltage Offset Correction: v_off_ini = 389.703 uV, v_off_fin = 396.682 uV 12:35:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.169 uVs 12:35:06 I2X Average and RMS of Measurements VT = -123.257 +- 0.638 uVs I2X = 11.340 +- 0.059 uTm^2 12:35:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:14 Integrated Voltage Measurement... 12:35:23 Voltage Offset Correction: v_off_ini = 382.485 uV, v_off_fin = 387.071 uV 12:35:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.409 uVs 12:35:23 Integrated Voltage Measurement... 12:35:32 Voltage Offset Correction: v_off_ini = 391.524 uV, v_off_fin = 402.045 uV 12:35:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.508 uVs 12:35:32 Integrated Voltage Measurement... 12:35:41 Voltage Offset Correction: v_off_ini = 396.587 uV, v_off_fin = 392.380 uV 12:35:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.903 uVs 12:35:41 Integrated Voltage Measurement... 12:35:50 Voltage Offset Correction: v_off_ini = 397.074 uV, v_off_fin = 406.154 uV 12:35:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.262 uVs 12:35:50 Integrated Voltage Measurement... 12:35:59 Voltage Offset Correction: v_off_ini = 416.491 uV, v_off_fin = 406.278 uV 12:35:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.140 uVs 12:35:59 Integrated Voltage Measurement... 12:36:08 Voltage Offset Correction: v_off_ini = 402.816 uV, v_off_fin = 391.446 uV 12:36:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.693 uVs 12:36:11 I2Y Average and RMS of Measurements VT = -193.819 +- 5.553 uVs I2Y = -17.832 +- 0.511 uTm^2 12:36:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm