SLAC Magnetic Measurements Date: 11-21-2025 Time: 14:20:38 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16338 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 14:20:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:48 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:50 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:51 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:53 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:21:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:21:38 Integrated Voltage Measurement... 14:21:47 Voltage Offset Correction: v_off_ini = 343.304 uV, v_off_fin = 345.173 uV 14:21:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -97.487 uVs 14:21:47 Integrated Voltage Measurement... 14:21:56 Voltage Offset Correction: v_off_ini = 345.362 uV, v_off_fin = 354.244 uV 14:21:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.820 uVs 14:21:56 Integrated Voltage Measurement... 14:22:05 Voltage Offset Correction: v_off_ini = 333.495 uV, v_off_fin = 340.977 uV 14:22:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.365 uVs 14:22:05 Integrated Voltage Measurement... 14:22:14 Voltage Offset Correction: v_off_ini = 338.835 uV, v_off_fin = 347.770 uV 14:22:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.168 uVs 14:22:14 Integrated Voltage Measurement... 14:22:23 Voltage Offset Correction: v_off_ini = 324.218 uV, v_off_fin = 339.514 uV 14:22:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.269 uVs 14:22:23 Integrated Voltage Measurement... 14:22:32 Voltage Offset Correction: v_off_ini = 345.954 uV, v_off_fin = 327.263 uV 14:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.201 uVs 14:22:36 I1X Average and RMS of Measurements VT = -88.218 +- 1.520 uVs I1X = 17.645 +- 0.303 uTm 14:22:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:22:43 Integrated Voltage Measurement... 14:22:52 Voltage Offset Correction: v_off_ini = 328.143 uV, v_off_fin = 329.673 uV 14:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -142.356 uVs 14:22:52 Integrated Voltage Measurement... 14:23:01 Voltage Offset Correction: v_off_ini = 329.485 uV, v_off_fin = 342.663 uV 14:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.921 uVs 14:23:01 Integrated Voltage Measurement... 14:23:10 Voltage Offset Correction: v_off_ini = 332.825 uV, v_off_fin = 321.014 uV 14:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.903 uVs 14:23:10 Integrated Voltage Measurement... 14:23:19 Voltage Offset Correction: v_off_ini = 338.542 uV, v_off_fin = 351.766 uV 14:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 147.492 uVs 14:23:19 Integrated Voltage Measurement... 14:23:28 Voltage Offset Correction: v_off_ini = 343.892 uV, v_off_fin = 328.498 uV 14:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -129.578 uVs 14:23:28 Integrated Voltage Measurement... 14:23:37 Voltage Offset Correction: v_off_ini = 344.018 uV, v_off_fin = 354.836 uV 14:23:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.507 uVs 14:23:41 I1Y Average and RMS of Measurements VT = -146.460 +- 2.698 uVs I1Y = -29.292 +- 0.540 uTm 14:23:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:23:49 Integrated Voltage Measurement... 14:23:58 Voltage Offset Correction: v_off_ini = 351.284 uV, v_off_fin = 337.567 uV 14:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.402 uVs 14:23:58 Integrated Voltage Measurement... 14:24:07 Voltage Offset Correction: v_off_ini = 355.227 uV, v_off_fin = 353.737 uV 14:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.626 uVs 14:24:07 Integrated Voltage Measurement... 14:24:16 Voltage Offset Correction: v_off_ini = 340.748 uV, v_off_fin = 331.355 uV 14:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.785 uVs 14:24:16 Integrated Voltage Measurement... 14:24:25 Voltage Offset Correction: v_off_ini = 337.760 uV, v_off_fin = 341.553 uV 14:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.330 uVs 14:24:25 Integrated Voltage Measurement... 14:24:34 Voltage Offset Correction: v_off_ini = 343.178 uV, v_off_fin = 335.700 uV 14:24:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.832 uVs 14:24:34 Integrated Voltage Measurement... 14:24:43 Voltage Offset Correction: v_off_ini = 351.413 uV, v_off_fin = 349.521 uV 14:24:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.200 uVs 14:24:45 I2X Average and RMS of Measurements VT = -71.529 +- 6.400 uVs I2X = 6.581 +- 0.589 uTm^2 14:24:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:24:53 Integrated Voltage Measurement... 14:25:02 Voltage Offset Correction: v_off_ini = 313.966 uV, v_off_fin = 329.664 uV 14:25:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.119 uVs 14:25:02 Integrated Voltage Measurement... 14:25:11 Voltage Offset Correction: v_off_ini = 327.161 uV, v_off_fin = 340.305 uV 14:25:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.491 uVs 14:25:11 Integrated Voltage Measurement... 14:25:20 Voltage Offset Correction: v_off_ini = 342.183 uV, v_off_fin = 345.036 uV 14:25:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.317 uVs 14:25:20 Integrated Voltage Measurement... 14:25:29 Voltage Offset Correction: v_off_ini = 337.559 uV, v_off_fin = 335.837 uV 14:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.258 uVs 14:25:29 Integrated Voltage Measurement... 14:25:38 Voltage Offset Correction: v_off_ini = 320.026 uV, v_off_fin = 333.152 uV 14:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.158 uVs 14:25:38 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = 326.797 uV, v_off_fin = 322.116 uV 14:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.096 uVs 14:25:50 I2Y Average and RMS of Measurements VT = -185.573 +- 3.288 uVs I2Y = -17.073 +- 0.303 uTm^2 14:25:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:25:59 Integrated Voltage Measurement... 14:26:08 Voltage Offset Correction: v_off_ini = 340.278 uV, v_off_fin = 343.064 uV 14:26:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.766 uVs 14:26:08 Integrated Voltage Measurement... 14:26:17 Voltage Offset Correction: v_off_ini = 334.233 uV, v_off_fin = 336.490 uV 14:26:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.359 uVs 14:26:17 Integrated Voltage Measurement... 14:26:26 Voltage Offset Correction: v_off_ini = 320.538 uV, v_off_fin = 343.637 uV 14:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.259 uVs 14:26:26 Integrated Voltage Measurement... 14:26:35 Voltage Offset Correction: v_off_ini = 331.546 uV, v_off_fin = 350.569 uV 14:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.644 uVs 14:26:35 Integrated Voltage Measurement... 14:26:44 Voltage Offset Correction: v_off_ini = 338.632 uV, v_off_fin = 330.356 uV 14:26:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.951 uVs 14:26:44 Integrated Voltage Measurement... 14:26:53 Voltage Offset Correction: v_off_ini = 326.960 uV, v_off_fin = 351.966 uV 14:26:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 58.174 uVs 14:26:57 I1X Average and RMS of Measurements VT = -72.359 +- 5.574 uVs I1X = 14.472 +- 1.116 uTm 14:26:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:27:04 Integrated Voltage Measurement... 14:27:13 Voltage Offset Correction: v_off_ini = 345.554 uV, v_off_fin = 334.590 uV 14:27:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.753 uVs 14:27:13 Integrated Voltage Measurement... 14:27:22 Voltage Offset Correction: v_off_ini = 344.576 uV, v_off_fin = 341.704 uV 14:27:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.885 uVs 14:27:22 Integrated Voltage Measurement... 14:27:31 Voltage Offset Correction: v_off_ini = 352.963 uV, v_off_fin = 337.750 uV 14:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.536 uVs 14:27:31 Integrated Voltage Measurement... 14:27:39 Voltage Offset Correction: v_off_ini = 340.340 uV, v_off_fin = 352.575 uV 14:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.546 uVs 14:27:40 Integrated Voltage Measurement... 14:27:48 Voltage Offset Correction: v_off_ini = 341.596 uV, v_off_fin = 341.908 uV 14:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -131.466 uVs 14:27:49 Integrated Voltage Measurement... 14:27:57 Voltage Offset Correction: v_off_ini = 328.088 uV, v_off_fin = 339.053 uV 14:27:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 147.063 uVs 14:28:02 I1Y Average and RMS of Measurements VT = -150.208 +- 10.594 uVs I1Y = -30.042 +- 2.119 uTm 14:28:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:28:09 Integrated Voltage Measurement... 14:28:18 Voltage Offset Correction: v_off_ini = 350.786 uV, v_off_fin = 327.650 uV 14:28:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.712 uVs 14:28:18 Integrated Voltage Measurement... 14:28:27 Voltage Offset Correction: v_off_ini = 341.357 uV, v_off_fin = 340.017 uV 14:28:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.515 uVs 14:28:27 Integrated Voltage Measurement... 14:28:36 Voltage Offset Correction: v_off_ini = 337.101 uV, v_off_fin = 302.477 uV 14:28:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.748 uVs 14:28:37 Integrated Voltage Measurement... 14:28:46 Voltage Offset Correction: v_off_ini = 324.922 uV, v_off_fin = 334.795 uV 14:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.984 uVs 14:28:46 Integrated Voltage Measurement... 14:28:55 Voltage Offset Correction: v_off_ini = 341.939 uV, v_off_fin = 335.626 uV 14:28:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.769 uVs 14:28:55 Integrated Voltage Measurement... 14:29:04 Voltage Offset Correction: v_off_ini = 344.706 uV, v_off_fin = 341.059 uV 14:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.311 uVs 14:29:06 I2X Average and RMS of Measurements VT = -59.340 +- 6.058 uVs I2X = 5.459 +- 0.557 uTm^2 14:29:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:29:14 Integrated Voltage Measurement... 14:29:23 Voltage Offset Correction: v_off_ini = 329.534 uV, v_off_fin = 350.783 uV 14:29:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.974 uVs 14:29:23 Integrated Voltage Measurement... 14:29:32 Voltage Offset Correction: v_off_ini = 321.364 uV, v_off_fin = 339.108 uV 14:29:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.155 uVs 14:29:32 Integrated Voltage Measurement... 14:29:41 Voltage Offset Correction: v_off_ini = 332.184 uV, v_off_fin = 343.839 uV 14:29:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.097 uVs 14:29:41 Integrated Voltage Measurement... 14:29:50 Voltage Offset Correction: v_off_ini = 334.604 uV, v_off_fin = 337.588 uV 14:29:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.158 uVs 14:29:50 Integrated Voltage Measurement... 14:29:59 Voltage Offset Correction: v_off_ini = 327.774 uV, v_off_fin = 340.383 uV 14:29:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.022 uVs 14:29:59 Integrated Voltage Measurement... 14:30:08 Voltage Offset Correction: v_off_ini = 340.429 uV, v_off_fin = 348.445 uV 14:30:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.666 uVs 14:30:10 I2Y Average and RMS of Measurements VT = -184.512 +- 6.832 uVs I2Y = -16.975 +- 0.629 uTm^2 14:30:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:19 Integrated Voltage Measurement... 14:30:28 Voltage Offset Correction: v_off_ini = 338.548 uV, v_off_fin = 329.767 uV 14:30:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -62.633 uVs 14:30:28 Integrated Voltage Measurement... 14:30:37 Voltage Offset Correction: v_off_ini = 328.778 uV, v_off_fin = 334.923 uV 14:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.362 uVs 14:30:37 Integrated Voltage Measurement... 14:30:46 Voltage Offset Correction: v_off_ini = 338.513 uV, v_off_fin = 336.267 uV 14:30:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.401 uVs 14:30:46 Integrated Voltage Measurement... 14:30:55 Voltage Offset Correction: v_off_ini = 330.319 uV, v_off_fin = 320.341 uV 14:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.977 uVs 14:30:55 Integrated Voltage Measurement... 14:31:04 Voltage Offset Correction: v_off_ini = 333.220 uV, v_off_fin = 328.292 uV 14:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.851 uVs 14:31:04 Integrated Voltage Measurement... 14:31:13 Voltage Offset Correction: v_off_ini = 330.575 uV, v_off_fin = 334.066 uV 14:31:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.875 uVs 14:31:17 I1X Average and RMS of Measurements VT = -56.183 +- 5.111 uVs I1X = 11.237 +- 1.023 uTm 14:31:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:24 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = 329.056 uV, v_off_fin = 333.010 uV 14:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.237 uVs 14:31:33 Integrated Voltage Measurement... 14:31:42 Voltage Offset Correction: v_off_ini = 349.288 uV, v_off_fin = 362.511 uV 14:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 127.979 uVs 14:31:42 Integrated Voltage Measurement... 14:31:51 Voltage Offset Correction: v_off_ini = 361.209 uV, v_off_fin = 341.373 uV 14:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.870 uVs 14:31:51 Integrated Voltage Measurement... 14:32:00 Voltage Offset Correction: v_off_ini = 343.814 uV, v_off_fin = 348.205 uV 14:32:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.463 uVs 14:32:00 Integrated Voltage Measurement... 14:32:09 Voltage Offset Correction: v_off_ini = 320.283 uV, v_off_fin = 315.450 uV 14:32:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -130.196 uVs 14:32:09 Integrated Voltage Measurement... 14:32:18 Voltage Offset Correction: v_off_ini = 337.867 uV, v_off_fin = 343.354 uV 14:32:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.385 uVs 14:32:22 I1Y Average and RMS of Measurements VT = -137.855 +- 0.492 uVs I1Y = -27.571 +- 0.098 uTm 14:32:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:30 Integrated Voltage Measurement... 14:32:39 Voltage Offset Correction: v_off_ini = 319.656 uV, v_off_fin = 309.465 uV 14:32:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.773 uVs 14:32:39 Integrated Voltage Measurement... 14:32:48 Voltage Offset Correction: v_off_ini = 329.829 uV, v_off_fin = 333.620 uV 14:32:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.947 uVs 14:32:48 Integrated Voltage Measurement... 14:32:57 Voltage Offset Correction: v_off_ini = 337.176 uV, v_off_fin = 323.321 uV 14:32:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.019 uVs 14:32:57 Integrated Voltage Measurement... 14:33:06 Voltage Offset Correction: v_off_ini = 336.670 uV, v_off_fin = 343.314 uV 14:33:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.473 uVs 14:33:06 Integrated Voltage Measurement... 14:33:15 Voltage Offset Correction: v_off_ini = 333.422 uV, v_off_fin = 333.172 uV 14:33:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.161 uVs 14:33:15 Integrated Voltage Measurement... 14:33:24 Voltage Offset Correction: v_off_ini = 352.291 uV, v_off_fin = 350.771 uV 14:33:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 26.537 uVs 14:33:27 I2X Average and RMS of Measurements VT = -38.318 +- 2.236 uVs I2X = 3.525 +- 0.206 uTm^2 14:33:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:34 Integrated Voltage Measurement... 14:33:43 Voltage Offset Correction: v_off_ini = 350.284 uV, v_off_fin = 353.801 uV 14:33:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.376 uVs 14:33:43 Integrated Voltage Measurement... 14:33:52 Voltage Offset Correction: v_off_ini = 357.860 uV, v_off_fin = 359.118 uV 14:33:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 168.002 uVs 14:33:52 Integrated Voltage Measurement... 14:34:01 Voltage Offset Correction: v_off_ini = 365.395 uV, v_off_fin = 349.078 uV 14:34:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.975 uVs 14:34:01 Integrated Voltage Measurement... 14:34:10 Voltage Offset Correction: v_off_ini = 327.946 uV, v_off_fin = 335.009 uV 14:34:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.041 uVs 14:34:10 Integrated Voltage Measurement... 14:34:19 Voltage Offset Correction: v_off_ini = 341.892 uV, v_off_fin = 340.521 uV 14:34:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.725 uVs 14:34:19 Integrated Voltage Measurement... 14:34:28 Voltage Offset Correction: v_off_ini = 350.827 uV, v_off_fin = 349.597 uV 14:34:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.440 uVs 14:34:31 I2Y Average and RMS of Measurements VT = -176.427 +- 7.071 uVs I2Y = -16.231 +- 0.651 uTm^2 14:34:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:34:40 Integrated Voltage Measurement... 14:34:49 Voltage Offset Correction: v_off_ini = 335.024 uV, v_off_fin = 338.190 uV 14:34:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -28.272 uVs 14:34:49 Integrated Voltage Measurement... 14:34:58 Voltage Offset Correction: v_off_ini = 323.558 uV, v_off_fin = 324.821 uV 14:34:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.574 uVs 14:34:58 Integrated Voltage Measurement... 14:35:07 Voltage Offset Correction: v_off_ini = 318.634 uV, v_off_fin = 321.129 uV 14:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.978 uVs 14:35:07 Integrated Voltage Measurement... 14:35:16 Voltage Offset Correction: v_off_ini = 304.190 uV, v_off_fin = 316.965 uV 14:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.541 uVs 14:35:16 Integrated Voltage Measurement... 14:35:25 Voltage Offset Correction: v_off_ini = 335.400 uV, v_off_fin = 348.995 uV 14:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.582 uVs 14:35:25 Integrated Voltage Measurement... 14:35:34 Voltage Offset Correction: v_off_ini = 347.475 uV, v_off_fin = 332.433 uV 14:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.594 uVs 14:35:38 I1X Average and RMS of Measurements VT = -41.257 +- 6.029 uVs I1X = 8.251 +- 1.206 uTm 14:35:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:35:44 Integrated Voltage Measurement... 14:35:53 Voltage Offset Correction: v_off_ini = 322.129 uV, v_off_fin = 328.765 uV 14:35:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.593 uVs 14:35:53 Integrated Voltage Measurement... 14:36:02 Voltage Offset Correction: v_off_ini = 321.555 uV, v_off_fin = 334.310 uV 14:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.576 uVs 14:36:02 Integrated Voltage Measurement... 14:36:11 Voltage Offset Correction: v_off_ini = 321.707 uV, v_off_fin = 323.505 uV 14:36:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.779 uVs 14:36:11 Integrated Voltage Measurement... 14:36:20 Voltage Offset Correction: v_off_ini = 334.539 uV, v_off_fin = 339.225 uV 14:36:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.715 uVs 14:36:20 Integrated Voltage Measurement... 14:36:29 Voltage Offset Correction: v_off_ini = 334.349 uV, v_off_fin = 324.280 uV 14:36:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -138.137 uVs 14:36:29 Integrated Voltage Measurement... 14:36:38 Voltage Offset Correction: v_off_ini = 329.151 uV, v_off_fin = 340.419 uV 14:36:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.017 uVs 14:36:42 I1Y Average and RMS of Measurements VT = -144.969 +- 0.835 uVs I1Y = -28.994 +- 0.167 uTm 14:36:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:36:50 Integrated Voltage Measurement... 14:36:59 Voltage Offset Correction: v_off_ini = 309.156 uV, v_off_fin = 314.195 uV 14:37:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.416 uVs 14:37:00 Integrated Voltage Measurement... 14:37:09 Voltage Offset Correction: v_off_ini = 320.325 uV, v_off_fin = 306.880 uV 14:37:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.683 uVs 14:37:09 Integrated Voltage Measurement... 14:37:18 Voltage Offset Correction: v_off_ini = 313.422 uV, v_off_fin = 317.349 uV 14:37:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.196 uVs 14:37:18 Integrated Voltage Measurement... 14:37:27 Voltage Offset Correction: v_off_ini = 303.849 uV, v_off_fin = 330.614 uV 14:37:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.459 uVs 14:37:27 Integrated Voltage Measurement... 14:37:36 Voltage Offset Correction: v_off_ini = 328.332 uV, v_off_fin = 325.196 uV 14:37:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.912 uVs 14:37:36 Integrated Voltage Measurement... 14:37:45 Voltage Offset Correction: v_off_ini = 327.998 uV, v_off_fin = 336.465 uV 14:37:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.520 uVs 14:37:47 I2X Average and RMS of Measurements VT = -30.031 +- 6.321 uVs I2X = 2.763 +- 0.582 uTm^2 14:37:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:37:55 Integrated Voltage Measurement... 14:38:04 Voltage Offset Correction: v_off_ini = 331.963 uV, v_off_fin = 329.222 uV 14:38:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.523 uVs 14:38:04 Integrated Voltage Measurement... 14:38:13 Voltage Offset Correction: v_off_ini = 328.512 uV, v_off_fin = 326.659 uV 14:38:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.613 uVs 14:38:13 Integrated Voltage Measurement... 14:38:22 Voltage Offset Correction: v_off_ini = 322.996 uV, v_off_fin = 314.238 uV 14:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.899 uVs 14:38:22 Integrated Voltage Measurement... 14:38:31 Voltage Offset Correction: v_off_ini = 317.645 uV, v_off_fin = 328.586 uV 14:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.963 uVs 14:38:31 Integrated Voltage Measurement... 14:38:40 Voltage Offset Correction: v_off_ini = 329.359 uV, v_off_fin = 317.400 uV 14:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.770 uVs 14:38:40 Integrated Voltage Measurement... 14:38:49 Voltage Offset Correction: v_off_ini = 307.482 uV, v_off_fin = 307.517 uV 14:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.892 uVs 14:38:52 I2Y Average and RMS of Measurements VT = -180.777 +- 7.096 uVs I2Y = -16.631 +- 0.653 uTm^2 14:38:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:39:00 Integrated Voltage Measurement... 14:39:09 Voltage Offset Correction: v_off_ini = 327.007 uV, v_off_fin = 344.968 uV 14:39:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -13.386 uVs 14:39:09 Integrated Voltage Measurement... 14:39:18 Voltage Offset Correction: v_off_ini = 338.545 uV, v_off_fin = 325.107 uV 14:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -3.692 uVs 14:39:18 Integrated Voltage Measurement... 14:39:27 Voltage Offset Correction: v_off_ini = 328.755 uV, v_off_fin = 328.358 uV 14:39:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.947 uVs 14:39:27 Integrated Voltage Measurement... 14:39:36 Voltage Offset Correction: v_off_ini = 311.701 uV, v_off_fin = 320.565 uV 14:39:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.445 uVs 14:39:37 Integrated Voltage Measurement... 14:39:45 Voltage Offset Correction: v_off_ini = 324.443 uV, v_off_fin = 315.657 uV 14:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.378 uVs 14:39:46 Integrated Voltage Measurement... 14:39:54 Voltage Offset Correction: v_off_ini = 310.710 uV, v_off_fin = 311.150 uV 14:39:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.528 uVs 14:39:59 I1X Average and RMS of Measurements VT = -27.665 +- 16.722 uVs I1X = 5.533 +- 3.344 uTm 14:40:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:40:05 Integrated Voltage Measurement... 14:40:14 Voltage Offset Correction: v_off_ini = 317.237 uV, v_off_fin = 293.904 uV 14:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -132.334 uVs 14:40:14 Integrated Voltage Measurement... 14:40:23 Voltage Offset Correction: v_off_ini = 326.578 uV, v_off_fin = 344.555 uV 14:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.445 uVs 14:40:23 Integrated Voltage Measurement... 14:40:32 Voltage Offset Correction: v_off_ini = 325.730 uV, v_off_fin = 313.960 uV 14:40:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.397 uVs 14:40:32 Integrated Voltage Measurement... 14:40:41 Voltage Offset Correction: v_off_ini = 334.894 uV, v_off_fin = 346.375 uV 14:40:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.290 uVs 14:40:41 Integrated Voltage Measurement... 14:40:50 Voltage Offset Correction: v_off_ini = 345.259 uV, v_off_fin = 330.480 uV 14:40:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.609 uVs 14:40:50 Integrated Voltage Measurement... 14:40:59 Voltage Offset Correction: v_off_ini = 324.083 uV, v_off_fin = 342.829 uV 14:40:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 143.296 uVs 14:41:04 I1Y Average and RMS of Measurements VT = -144.062 +- 4.595 uVs I1Y = -28.813 +- 0.920 uTm 14:41:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:41:11 Integrated Voltage Measurement... 14:41:20 Voltage Offset Correction: v_off_ini = 330.758 uV, v_off_fin = 327.149 uV 14:41:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.165 uVs 14:41:20 Integrated Voltage Measurement... 14:41:29 Voltage Offset Correction: v_off_ini = 335.573 uV, v_off_fin = 345.353 uV 14:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 0.691 uVs 14:41:29 Integrated Voltage Measurement... 14:41:38 Voltage Offset Correction: v_off_ini = 337.049 uV, v_off_fin = 331.902 uV 14:41:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.311 uVs 14:41:38 Integrated Voltage Measurement... 14:41:47 Voltage Offset Correction: v_off_ini = 334.337 uV, v_off_fin = 341.790 uV 14:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.592 uVs 14:41:47 Integrated Voltage Measurement... 14:41:56 Voltage Offset Correction: v_off_ini = 334.538 uV, v_off_fin = 318.599 uV 14:41:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.061 uVs 14:41:56 Integrated Voltage Measurement... 14:42:05 Voltage Offset Correction: v_off_ini = 322.775 uV, v_off_fin = 338.663 uV 14:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.361 uVs 14:42:08 I2X Average and RMS of Measurements VT = -18.197 +- 9.180 uVs I2X = 1.674 +- 0.845 uTm^2 14:42:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:42:15 Integrated Voltage Measurement... 14:42:24 Voltage Offset Correction: v_off_ini = 311.532 uV, v_off_fin = 329.072 uV 14:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.437 uVs 14:42:24 Integrated Voltage Measurement... 14:42:33 Voltage Offset Correction: v_off_ini = 338.094 uV, v_off_fin = 342.318 uV 14:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.598 uVs 14:42:34 Integrated Voltage Measurement... 14:42:42 Voltage Offset Correction: v_off_ini = 336.869 uV, v_off_fin = 321.223 uV 14:42:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.258 uVs 14:42:43 Integrated Voltage Measurement... 14:42:52 Voltage Offset Correction: v_off_ini = 353.732 uV, v_off_fin = 339.016 uV 14:42:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.964 uVs 14:42:52 Integrated Voltage Measurement... 14:43:01 Voltage Offset Correction: v_off_ini = 366.524 uV, v_off_fin = 344.305 uV 14:43:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.334 uVs 14:43:01 Integrated Voltage Measurement... 14:43:10 Voltage Offset Correction: v_off_ini = 334.798 uV, v_off_fin = 324.194 uV 14:43:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.878 uVs 14:43:12 I2Y Average and RMS of Measurements VT = -184.245 +- 4.696 uVs I2Y = -16.951 +- 0.432 uTm^2 14:43:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:43:24 Integrated Voltage Measurement... 14:43:33 Voltage Offset Correction: v_off_ini = 345.804 uV, v_off_fin = 336.541 uV 14:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.080 uVs 14:43:33 Integrated Voltage Measurement... 14:43:42 Voltage Offset Correction: v_off_ini = 323.360 uV, v_off_fin = 318.721 uV 14:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.750 uVs 14:43:42 Integrated Voltage Measurement... 14:43:51 Voltage Offset Correction: v_off_ini = 326.609 uV, v_off_fin = 314.806 uV 14:43:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.853 uVs 14:43:51 Integrated Voltage Measurement... 14:44:00 Voltage Offset Correction: v_off_ini = 315.530 uV, v_off_fin = 315.701 uV 14:44:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 31.801 uVs 14:44:00 Integrated Voltage Measurement... 14:44:09 Voltage Offset Correction: v_off_ini = 311.568 uV, v_off_fin = 309.069 uV 14:44:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -43.493 uVs 14:44:09 Integrated Voltage Measurement... 14:44:18 Voltage Offset Correction: v_off_ini = 313.625 uV, v_off_fin = 305.911 uV 14:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.294 uVs 14:44:22 I1X Average and RMS of Measurements VT = -46.545 +- 4.732 uVs I1X = 9.310 +- 0.946 uTm 14:44:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:44:29 Integrated Voltage Measurement... 14:44:38 Voltage Offset Correction: v_off_ini = 311.081 uV, v_off_fin = 305.326 uV 14:44:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.551 uVs 14:44:38 Integrated Voltage Measurement... 14:44:47 Voltage Offset Correction: v_off_ini = 319.028 uV, v_off_fin = 345.302 uV 14:44:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.604 uVs 14:44:47 Integrated Voltage Measurement... 14:44:56 Voltage Offset Correction: v_off_ini = 326.176 uV, v_off_fin = 332.503 uV 14:44:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.908 uVs 14:44:56 Integrated Voltage Measurement... 14:45:05 Voltage Offset Correction: v_off_ini = 318.911 uV, v_off_fin = 323.948 uV 14:45:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.167 uVs 14:45:05 Integrated Voltage Measurement... 14:45:14 Voltage Offset Correction: v_off_ini = 336.684 uV, v_off_fin = 321.630 uV 14:45:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.191 uVs 14:45:14 Integrated Voltage Measurement... 14:45:23 Voltage Offset Correction: v_off_ini = 326.483 uV, v_off_fin = 339.200 uV 14:45:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.874 uVs 14:45:27 I1Y Average and RMS of Measurements VT = -163.216 +- 2.634 uVs I1Y = -32.643 +- 0.527 uTm 14:45:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:45:32 Integrated Voltage Measurement... 14:45:41 Voltage Offset Correction: v_off_ini = 331.016 uV, v_off_fin = 330.470 uV 14:45:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.774 uVs 14:45:41 Integrated Voltage Measurement... 14:45:50 Voltage Offset Correction: v_off_ini = 330.017 uV, v_off_fin = 344.849 uV 14:45:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.413 uVs 14:45:50 Integrated Voltage Measurement... 14:45:59 Voltage Offset Correction: v_off_ini = 351.415 uV, v_off_fin = 340.689 uV 14:45:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.982 uVs 14:45:59 Integrated Voltage Measurement... 14:46:08 Voltage Offset Correction: v_off_ini = 346.490 uV, v_off_fin = 338.098 uV 14:46:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.791 uVs 14:46:08 Integrated Voltage Measurement... 14:46:17 Voltage Offset Correction: v_off_ini = 346.453 uV, v_off_fin = 329.885 uV 14:46:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.209 uVs 14:46:17 Integrated Voltage Measurement... 14:46:26 Voltage Offset Correction: v_off_ini = 338.372 uV, v_off_fin = 350.243 uV 14:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.360 uVs 14:46:29 I2X Average and RMS of Measurements VT = -38.255 +- 3.927 uVs I2X = 3.519 +- 0.361 uTm^2 14:46:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:46:34 Integrated Voltage Measurement... 14:46:43 Voltage Offset Correction: v_off_ini = 328.289 uV, v_off_fin = 322.966 uV 14:46:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.796 uVs 14:46:43 Integrated Voltage Measurement... 14:46:52 Voltage Offset Correction: v_off_ini = 317.016 uV, v_off_fin = 314.731 uV 14:46:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 204.381 uVs 14:46:52 Integrated Voltage Measurement... 14:47:01 Voltage Offset Correction: v_off_ini = 315.019 uV, v_off_fin = 314.576 uV 14:47:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.804 uVs 14:47:01 Integrated Voltage Measurement... 14:47:10 Voltage Offset Correction: v_off_ini = 312.384 uV, v_off_fin = 307.629 uV 14:47:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.088 uVs 14:47:10 Integrated Voltage Measurement... 14:47:19 Voltage Offset Correction: v_off_ini = 309.946 uV, v_off_fin = 307.834 uV 14:47:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.851 uVs 14:47:19 Integrated Voltage Measurement... 14:47:28 Voltage Offset Correction: v_off_ini = 308.654 uV, v_off_fin = 319.576 uV 14:47:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.221 uVs 14:47:30 I2Y Average and RMS of Measurements VT = -195.690 +- 7.362 uVs I2Y = -18.004 +- 0.678 uTm^2 14:47:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:47:39 Integrated Voltage Measurement... 14:47:48 Voltage Offset Correction: v_off_ini = 308.463 uV, v_off_fin = 316.236 uV 14:47:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -45.484 uVs 14:47:48 Integrated Voltage Measurement... 14:47:57 Voltage Offset Correction: v_off_ini = 330.540 uV, v_off_fin = 325.171 uV 14:47:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.938 uVs 14:47:57 Integrated Voltage Measurement... 14:48:06 Voltage Offset Correction: v_off_ini = 329.548 uV, v_off_fin = 335.073 uV 14:48:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.941 uVs 14:48:06 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = 332.113 uV, v_off_fin = 326.833 uV 14:48:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 24.531 uVs 14:48:15 Integrated Voltage Measurement... 14:48:24 Voltage Offset Correction: v_off_ini = 349.241 uV, v_off_fin = 334.914 uV 14:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.224 uVs 14:48:24 Integrated Voltage Measurement... 14:48:33 Voltage Offset Correction: v_off_ini = 344.517 uV, v_off_fin = 354.251 uV 14:48:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.089 uVs 14:48:37 I1X Average and RMS of Measurements VT = -47.534 +- 8.858 uVs I1X = 9.507 +- 1.771 uTm 14:48:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:48:44 Integrated Voltage Measurement... 14:48:52 Voltage Offset Correction: v_off_ini = 338.921 uV, v_off_fin = 340.034 uV 14:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.109 uVs 14:48:53 Integrated Voltage Measurement... 14:49:01 Voltage Offset Correction: v_off_ini = 359.530 uV, v_off_fin = 364.293 uV 14:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.030 uVs 14:49:02 Integrated Voltage Measurement... 14:49:10 Voltage Offset Correction: v_off_ini = 359.976 uV, v_off_fin = 330.459 uV 14:49:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.990 uVs 14:49:11 Integrated Voltage Measurement... 14:49:19 Voltage Offset Correction: v_off_ini = 340.424 uV, v_off_fin = 338.178 uV 14:49:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.075 uVs 14:49:19 Integrated Voltage Measurement... 14:49:28 Voltage Offset Correction: v_off_ini = 347.672 uV, v_off_fin = 352.731 uV 14:49:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.432 uVs 14:49:28 Integrated Voltage Measurement... 14:49:37 Voltage Offset Correction: v_off_ini = 348.630 uV, v_off_fin = 349.582 uV 14:49:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.384 uVs 14:49:42 I1Y Average and RMS of Measurements VT = -156.337 +- 5.264 uVs I1Y = -31.267 +- 1.053 uTm 14:49:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:49:47 Integrated Voltage Measurement... 14:49:56 Voltage Offset Correction: v_off_ini = 339.276 uV, v_off_fin = 349.053 uV 14:49:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.199 uVs 14:49:56 Integrated Voltage Measurement... 14:50:05 Voltage Offset Correction: v_off_ini = 343.630 uV, v_off_fin = 347.156 uV 14:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.809 uVs 14:50:05 Integrated Voltage Measurement... 14:50:14 Voltage Offset Correction: v_off_ini = 336.958 uV, v_off_fin = 323.710 uV 14:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.376 uVs 14:50:14 Integrated Voltage Measurement... 14:50:23 Voltage Offset Correction: v_off_ini = 338.425 uV, v_off_fin = 347.328 uV 14:50:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.618 uVs 14:50:23 Integrated Voltage Measurement... 14:50:32 Voltage Offset Correction: v_off_ini = 327.535 uV, v_off_fin = 336.791 uV 14:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.472 uVs 14:50:32 Integrated Voltage Measurement... 14:50:41 Voltage Offset Correction: v_off_ini = 345.910 uV, v_off_fin = 341.825 uV 14:50:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 29.463 uVs 14:50:43 I2X Average and RMS of Measurements VT = -29.823 +- 2.891 uVs I2X = 2.744 +- 0.266 uTm^2 14:50:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:50:48 Integrated Voltage Measurement... 14:50:57 Voltage Offset Correction: v_off_ini = 351.938 uV, v_off_fin = 362.656 uV 14:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.689 uVs 14:50:57 Integrated Voltage Measurement... 14:51:06 Voltage Offset Correction: v_off_ini = 352.480 uV, v_off_fin = 356.988 uV 14:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.250 uVs 14:51:06 Integrated Voltage Measurement... 14:51:15 Voltage Offset Correction: v_off_ini = 345.910 uV, v_off_fin = 336.752 uV 14:51:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.249 uVs 14:51:15 Integrated Voltage Measurement... 14:51:24 Voltage Offset Correction: v_off_ini = 339.158 uV, v_off_fin = 337.225 uV 14:51:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.308 uVs 14:51:25 Integrated Voltage Measurement... 14:51:33 Voltage Offset Correction: v_off_ini = 328.841 uV, v_off_fin = 330.372 uV 14:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.464 uVs 14:51:34 Integrated Voltage Measurement... 14:51:43 Voltage Offset Correction: v_off_ini = 330.441 uV, v_off_fin = 333.576 uV 14:51:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.992 uVs 14:51:45 I2Y Average and RMS of Measurements VT = -189.659 +- 3.455 uVs I2Y = -17.449 +- 0.318 uTm^2 14:51:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 338.121 uV, v_off_fin = 344.938 uV 14:52:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.470 uVs 14:52:02 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 361.251 uV, v_off_fin = 353.746 uV 14:52:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.037 uVs 14:52:11 Integrated Voltage Measurement... 14:52:20 Voltage Offset Correction: v_off_ini = 354.847 uV, v_off_fin = 354.461 uV 14:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.432 uVs 14:52:20 Integrated Voltage Measurement... 14:52:29 Voltage Offset Correction: v_off_ini = 351.265 uV, v_off_fin = 365.668 uV 14:52:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.073 uVs 14:52:29 Integrated Voltage Measurement... 14:52:38 Voltage Offset Correction: v_off_ini = 343.057 uV, v_off_fin = 330.267 uV 14:52:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.228 uVs 14:52:38 Integrated Voltage Measurement... 14:52:47 Voltage Offset Correction: v_off_ini = 357.386 uV, v_off_fin = 369.342 uV 14:52:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.441 uVs 14:52:51 I1X Average and RMS of Measurements VT = -50.613 +- 3.697 uVs I1X = 10.123 +- 0.740 uTm 14:52:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:58 Integrated Voltage Measurement... 14:53:07 Voltage Offset Correction: v_off_ini = 343.584 uV, v_off_fin = 347.362 uV 14:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -134.502 uVs 14:53:07 Integrated Voltage Measurement... 14:53:16 Voltage Offset Correction: v_off_ini = 347.917 uV, v_off_fin = 347.640 uV 14:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.796 uVs 14:53:16 Integrated Voltage Measurement... 14:53:25 Voltage Offset Correction: v_off_ini = 340.517 uV, v_off_fin = 350.433 uV 14:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.798 uVs 14:53:25 Integrated Voltage Measurement... 14:53:34 Voltage Offset Correction: v_off_ini = 360.843 uV, v_off_fin = 356.339 uV 14:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.707 uVs 14:53:34 Integrated Voltage Measurement... 14:53:43 Voltage Offset Correction: v_off_ini = 338.942 uV, v_off_fin = 333.402 uV 14:53:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -148.961 uVs 14:53:43 Integrated Voltage Measurement... 14:53:52 Voltage Offset Correction: v_off_ini = 333.689 uV, v_off_fin = 335.085 uV 14:53:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 129.500 uVs 14:53:56 I1Y Average and RMS of Measurements VT = -139.544 +- 2.417 uVs I1Y = -27.909 +- 0.483 uTm 14:53:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:01 Integrated Voltage Measurement... 14:54:10 Voltage Offset Correction: v_off_ini = 327.671 uV, v_off_fin = 311.376 uV 14:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.901 uVs 14:54:10 Integrated Voltage Measurement... 14:54:19 Voltage Offset Correction: v_off_ini = 345.744 uV, v_off_fin = 357.339 uV 14:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.185 uVs 14:54:19 Integrated Voltage Measurement... 14:54:28 Voltage Offset Correction: v_off_ini = 336.722 uV, v_off_fin = 331.852 uV 14:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.416 uVs 14:54:29 Integrated Voltage Measurement... 14:54:37 Voltage Offset Correction: v_off_ini = 359.685 uV, v_off_fin = 353.428 uV 14:54:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.840 uVs 14:54:38 Integrated Voltage Measurement... 14:54:47 Voltage Offset Correction: v_off_ini = 346.058 uV, v_off_fin = 336.527 uV 14:54:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.347 uVs 14:54:47 Integrated Voltage Measurement... 14:54:56 Voltage Offset Correction: v_off_ini = 335.341 uV, v_off_fin = 338.009 uV 14:54:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.204 uVs 14:54:58 I2X Average and RMS of Measurements VT = -40.315 +- 3.026 uVs I2X = 3.709 +- 0.278 uTm^2 14:55:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:03 Integrated Voltage Measurement... 14:55:12 Voltage Offset Correction: v_off_ini = 358.890 uV, v_off_fin = 334.386 uV 14:55:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.401 uVs 14:55:12 Integrated Voltage Measurement... 14:55:21 Voltage Offset Correction: v_off_ini = 340.830 uV, v_off_fin = 351.710 uV 14:55:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.248 uVs 14:55:21 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = 340.009 uV, v_off_fin = 358.623 uV 14:55:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.046 uVs 14:55:30 Integrated Voltage Measurement... 14:55:39 Voltage Offset Correction: v_off_ini = 352.341 uV, v_off_fin = 332.864 uV 14:55:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.033 uVs 14:55:39 Integrated Voltage Measurement... 14:55:48 Voltage Offset Correction: v_off_ini = 341.211 uV, v_off_fin = 354.427 uV 14:55:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.579 uVs 14:55:48 Integrated Voltage Measurement... 14:55:57 Voltage Offset Correction: v_off_ini = 345.421 uV, v_off_fin = 340.375 uV 14:55:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.034 uVs 14:56:00 I2Y Average and RMS of Measurements VT = -182.223 +- 3.383 uVs I2Y = -16.765 +- 0.311 uTm^2 14:56:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:56:08 Integrated Voltage Measurement... 14:56:17 Voltage Offset Correction: v_off_ini = 339.830 uV, v_off_fin = 340.274 uV 14:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.960 uVs 14:56:17 Integrated Voltage Measurement... 14:56:26 Voltage Offset Correction: v_off_ini = 354.910 uV, v_off_fin = 352.684 uV 14:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.048 uVs 14:56:26 Integrated Voltage Measurement... 14:56:35 Voltage Offset Correction: v_off_ini = 342.193 uV, v_off_fin = 326.686 uV 14:56:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.384 uVs 14:56:35 Integrated Voltage Measurement... 14:56:44 Voltage Offset Correction: v_off_ini = 357.117 uV, v_off_fin = 362.492 uV 14:56:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.824 uVs 14:56:44 Integrated Voltage Measurement... 14:56:53 Voltage Offset Correction: v_off_ini = 335.723 uV, v_off_fin = 338.885 uV 14:56:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.349 uVs 14:56:53 Integrated Voltage Measurement... 14:57:02 Voltage Offset Correction: v_off_ini = 338.908 uV, v_off_fin = 344.529 uV 14:57:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.365 uVs 14:57:06 I1X Average and RMS of Measurements VT = -39.488 +- 6.989 uVs I1X = 7.898 +- 1.398 uTm 14:57:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:57:13 Integrated Voltage Measurement... 14:57:22 Voltage Offset Correction: v_off_ini = 315.199 uV, v_off_fin = 322.071 uV 14:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -142.943 uVs 14:57:22 Integrated Voltage Measurement... 14:57:31 Voltage Offset Correction: v_off_ini = 341.776 uV, v_off_fin = 336.512 uV 14:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 142.121 uVs 14:57:31 Integrated Voltage Measurement... 14:57:40 Voltage Offset Correction: v_off_ini = 327.568 uV, v_off_fin = 317.409 uV 14:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -123.123 uVs 14:57:40 Integrated Voltage Measurement... 14:57:49 Voltage Offset Correction: v_off_ini = 323.634 uV, v_off_fin = 340.998 uV 14:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 135.007 uVs 14:57:49 Integrated Voltage Measurement... 14:57:58 Voltage Offset Correction: v_off_ini = 352.528 uV, v_off_fin = 328.629 uV 14:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -128.876 uVs 14:57:58 Integrated Voltage Measurement... 14:58:07 Voltage Offset Correction: v_off_ini = 337.795 uV, v_off_fin = 351.649 uV 14:58:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 137.563 uVs 14:58:11 I1Y Average and RMS of Measurements VT = -134.939 +- 5.631 uVs I1Y = -26.985 +- 1.126 uTm 14:58:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:58:16 Integrated Voltage Measurement... 14:58:25 Voltage Offset Correction: v_off_ini = 331.861 uV, v_off_fin = 344.311 uV 14:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.819 uVs 14:58:25 Integrated Voltage Measurement... 14:58:34 Voltage Offset Correction: v_off_ini = 352.126 uV, v_off_fin = 368.503 uV 14:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.565 uVs 14:58:34 Integrated Voltage Measurement... 14:58:43 Voltage Offset Correction: v_off_ini = 344.026 uV, v_off_fin = 341.013 uV 14:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.959 uVs 14:58:43 Integrated Voltage Measurement... 14:58:52 Voltage Offset Correction: v_off_ini = 344.592 uV, v_off_fin = 351.347 uV 14:58:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.111 uVs 14:58:52 Integrated Voltage Measurement... 14:59:01 Voltage Offset Correction: v_off_ini = 337.759 uV, v_off_fin = 339.709 uV 14:59:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.418 uVs 14:59:01 Integrated Voltage Measurement... 14:59:10 Voltage Offset Correction: v_off_ini = 333.093 uV, v_off_fin = 343.596 uV 14:59:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.934 uVs 14:59:13 I2X Average and RMS of Measurements VT = -33.134 +- 8.317 uVs I2X = 3.048 +- 0.765 uTm^2 14:59:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:59:18 Integrated Voltage Measurement... 14:59:27 Voltage Offset Correction: v_off_ini = 322.121 uV, v_off_fin = 316.103 uV 14:59:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.841 uVs 14:59:27 Integrated Voltage Measurement... 14:59:36 Voltage Offset Correction: v_off_ini = 323.184 uV, v_off_fin = 324.750 uV 14:59:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 175.977 uVs 14:59:36 Integrated Voltage Measurement... 14:59:45 Voltage Offset Correction: v_off_ini = 330.474 uV, v_off_fin = 334.749 uV 14:59:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.349 uVs 14:59:45 Integrated Voltage Measurement... 14:59:54 Voltage Offset Correction: v_off_ini = 333.563 uV, v_off_fin = 323.679 uV 14:59:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.444 uVs 14:59:54 Integrated Voltage Measurement... 15:00:03 Voltage Offset Correction: v_off_ini = 324.756 uV, v_off_fin = 314.745 uV 15:00:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.681 uVs 15:00:03 Integrated Voltage Measurement... 15:00:12 Voltage Offset Correction: v_off_ini = 324.580 uV, v_off_fin = 344.811 uV 15:00:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.825 uVs 15:00:14 I2Y Average and RMS of Measurements VT = -175.353 +- 7.823 uVs I2Y = -16.133 +- 0.720 uTm^2 15:00:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:00:23 Integrated Voltage Measurement... 15:00:31 Voltage Offset Correction: v_off_ini = 347.605 uV, v_off_fin = 341.509 uV 15:00:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.416 uVs 15:00:32 Integrated Voltage Measurement... 15:00:40 Voltage Offset Correction: v_off_ini = 346.693 uV, v_off_fin = 338.267 uV 15:00:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 27.670 uVs 15:00:41 Integrated Voltage Measurement... 15:00:50 Voltage Offset Correction: v_off_ini = 341.122 uV, v_off_fin = 341.908 uV 15:00:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -13.872 uVs 15:00:50 Integrated Voltage Measurement... 15:00:59 Voltage Offset Correction: v_off_ini = 349.921 uV, v_off_fin = 344.810 uV 15:00:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.043 uVs 15:00:59 Integrated Voltage Measurement... 15:01:08 Voltage Offset Correction: v_off_ini = 335.182 uV, v_off_fin = 350.520 uV 15:01:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.645 uVs 15:01:08 Integrated Voltage Measurement... 15:01:17 Voltage Offset Correction: v_off_ini = 338.765 uV, v_off_fin = 340.877 uV 15:01:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.683 uVs 15:01:21 I1X Average and RMS of Measurements VT = -32.388 +- 3.139 uVs I1X = 6.478 +- 0.628 uTm 15:01:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:01:28 Integrated Voltage Measurement... 15:01:36 Voltage Offset Correction: v_off_ini = 347.683 uV, v_off_fin = 330.041 uV 15:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -124.306 uVs 15:01:37 Integrated Voltage Measurement... 15:01:45 Voltage Offset Correction: v_off_ini = 343.846 uV, v_off_fin = 359.439 uV 15:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 109.407 uVs 15:01:46 Integrated Voltage Measurement... 15:01:54 Voltage Offset Correction: v_off_ini = 333.184 uV, v_off_fin = 309.116 uV 15:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -117.733 uVs 15:01:54 Integrated Voltage Measurement... 15:02:03 Voltage Offset Correction: v_off_ini = 334.671 uV, v_off_fin = 337.321 uV 15:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 110.520 uVs 15:02:03 Integrated Voltage Measurement... 15:02:12 Voltage Offset Correction: v_off_ini = 328.030 uV, v_off_fin = 340.758 uV 15:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -109.718 uVs 15:02:12 Integrated Voltage Measurement... 15:02:21 Voltage Offset Correction: v_off_ini = 351.556 uV, v_off_fin = 355.348 uV 15:02:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 117.638 uVs 15:02:26 I1Y Average and RMS of Measurements VT = -114.887 +- 1.405 uVs I1Y = -22.975 +- 0.281 uTm 15:02:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:02:31 Integrated Voltage Measurement... 15:02:40 Voltage Offset Correction: v_off_ini = 338.937 uV, v_off_fin = 355.734 uV 15:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.106 uVs 15:02:40 Integrated Voltage Measurement... 15:02:49 Voltage Offset Correction: v_off_ini = 364.577 uV, v_off_fin = 354.829 uV 15:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.581 uVs 15:02:49 Integrated Voltage Measurement... 15:02:58 Voltage Offset Correction: v_off_ini = 345.240 uV, v_off_fin = 346.179 uV 15:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.940 uVs 15:02:58 Integrated Voltage Measurement... 15:03:07 Voltage Offset Correction: v_off_ini = 365.252 uV, v_off_fin = 363.351 uV 15:03:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.289 uVs 15:03:07 Integrated Voltage Measurement... 15:03:16 Voltage Offset Correction: v_off_ini = 369.285 uV, v_off_fin = 360.032 uV 15:03:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.095 uVs 15:03:16 Integrated Voltage Measurement... 15:03:25 Voltage Offset Correction: v_off_ini = 362.690 uV, v_off_fin = 374.846 uV 15:03:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.157 uVs 15:03:27 I2X Average and RMS of Measurements VT = -34.695 +- 5.031 uVs I2X = 3.192 +- 0.463 uTm^2 15:03:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:03:32 Integrated Voltage Measurement... 15:03:41 Voltage Offset Correction: v_off_ini = 369.767 uV, v_off_fin = 386.979 uV 15:03:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.020 uVs 15:03:41 Integrated Voltage Measurement... 15:03:50 Voltage Offset Correction: v_off_ini = 372.849 uV, v_off_fin = 369.970 uV 15:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 158.913 uVs 15:03:50 Integrated Voltage Measurement... 15:03:59 Voltage Offset Correction: v_off_ini = 371.751 uV, v_off_fin = 372.156 uV 15:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.875 uVs 15:03:59 Integrated Voltage Measurement... 15:04:08 Voltage Offset Correction: v_off_ini = 377.452 uV, v_off_fin = 357.073 uV 15:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.427 uVs 15:04:08 Integrated Voltage Measurement... 15:04:17 Voltage Offset Correction: v_off_ini = 357.796 uV, v_off_fin = 364.697 uV 15:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.218 uVs 15:04:17 Integrated Voltage Measurement... 15:04:26 Voltage Offset Correction: v_off_ini = 355.808 uV, v_off_fin = 349.290 uV 15:04:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.423 uVs 15:04:29 I2Y Average and RMS of Measurements VT = -167.146 +- 6.962 uVs I2Y = -15.377 +- 0.641 uTm^2 15:04:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:04:49 Integrated Voltage Measurement... 15:04:58 Voltage Offset Correction: v_off_ini = 401.075 uV, v_off_fin = 387.594 uV 15:04:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -107.173 uVs 15:04:58 Integrated Voltage Measurement... 15:05:07 Voltage Offset Correction: v_off_ini = 375.920 uV, v_off_fin = 368.902 uV 15:05:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.694 uVs 15:05:07 Integrated Voltage Measurement... 15:05:16 Voltage Offset Correction: v_off_ini = 344.162 uV, v_off_fin = 350.810 uV 15:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.340 uVs 15:05:16 Integrated Voltage Measurement... 15:05:25 Voltage Offset Correction: v_off_ini = 372.138 uV, v_off_fin = 373.523 uV 15:05:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.686 uVs 15:05:25 Integrated Voltage Measurement... 15:05:34 Voltage Offset Correction: v_off_ini = 356.739 uV, v_off_fin = 351.324 uV 15:05:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.352 uVs 15:05:34 Integrated Voltage Measurement... 15:05:43 Voltage Offset Correction: v_off_ini = 364.951 uV, v_off_fin = 369.512 uV 15:05:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.417 uVs 15:05:47 I1X Average and RMS of Measurements VT = -99.777 +- 5.152 uVs I1X = 19.956 +- 1.032 uTm 15:05:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:05:54 Integrated Voltage Measurement... 15:06:03 Voltage Offset Correction: v_off_ini = 352.377 uV, v_off_fin = 325.054 uV 15:06:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -151.523 uVs 15:06:03 Integrated Voltage Measurement... 15:06:12 Voltage Offset Correction: v_off_ini = 330.063 uV, v_off_fin = 351.838 uV 15:06:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.012 uVs 15:06:12 Integrated Voltage Measurement... 15:06:21 Voltage Offset Correction: v_off_ini = 342.472 uV, v_off_fin = 341.133 uV 15:06:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -168.090 uVs 15:06:21 Integrated Voltage Measurement... 15:06:30 Voltage Offset Correction: v_off_ini = 318.701 uV, v_off_fin = 349.573 uV 15:06:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.206 uVs 15:06:30 Integrated Voltage Measurement... 15:06:39 Voltage Offset Correction: v_off_ini = 323.439 uV, v_off_fin = 315.795 uV 15:06:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.760 uVs 15:06:39 Integrated Voltage Measurement... 15:06:48 Voltage Offset Correction: v_off_ini = 328.426 uV, v_off_fin = 357.307 uV 15:06:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.347 uVs 15:06:52 I1Y Average and RMS of Measurements VT = -165.490 +- 6.756 uVs I1Y = -33.100 +- 1.352 uTm 15:06:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:07:00 Integrated Voltage Measurement... 15:07:09 Voltage Offset Correction: v_off_ini = 351.788 uV, v_off_fin = 335.459 uV 15:07:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.941 uVs 15:07:09 Integrated Voltage Measurement... 15:07:18 Voltage Offset Correction: v_off_ini = 356.502 uV, v_off_fin = 369.493 uV 15:07:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.916 uVs 15:07:18 Integrated Voltage Measurement... 15:07:27 Voltage Offset Correction: v_off_ini = 362.314 uV, v_off_fin = 362.020 uV 15:07:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.312 uVs 15:07:27 Integrated Voltage Measurement... 15:07:36 Voltage Offset Correction: v_off_ini = 357.229 uV, v_off_fin = 355.853 uV 15:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.277 uVs 15:07:36 Integrated Voltage Measurement... 15:07:45 Voltage Offset Correction: v_off_ini = 352.137 uV, v_off_fin = 342.617 uV 15:07:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.886 uVs 15:07:45 Integrated Voltage Measurement... 15:07:54 Voltage Offset Correction: v_off_ini = 343.650 uV, v_off_fin = 347.883 uV 15:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.891 uVs 15:07:56 I2X Average and RMS of Measurements VT = -94.704 +- 8.289 uVs I2X = 8.713 +- 0.763 uTm^2 15:08:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:08:04 Integrated Voltage Measurement... 15:08:13 Voltage Offset Correction: v_off_ini = 357.421 uV, v_off_fin = 341.173 uV 15:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.968 uVs 15:08:13 Integrated Voltage Measurement... 15:08:22 Voltage Offset Correction: v_off_ini = 348.263 uV, v_off_fin = 354.102 uV 15:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.348 uVs 15:08:22 Integrated Voltage Measurement... 15:08:31 Voltage Offset Correction: v_off_ini = 341.138 uV, v_off_fin = 336.481 uV 15:08:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -207.562 uVs 15:08:31 Integrated Voltage Measurement... 15:08:40 Voltage Offset Correction: v_off_ini = 333.698 uV, v_off_fin = 357.997 uV 15:08:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.015 uVs 15:08:40 Integrated Voltage Measurement... 15:08:49 Voltage Offset Correction: v_off_ini = 345.243 uV, v_off_fin = 339.276 uV 15:08:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.336 uVs 15:08:49 Integrated Voltage Measurement... 15:08:58 Voltage Offset Correction: v_off_ini = 351.313 uV, v_off_fin = 352.472 uV 15:08:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.690 uVs 15:09:01 I2Y Average and RMS of Measurements VT = -198.986 +- 1.296 uVs I2Y = -18.307 +- 0.119 uTm^2 15:09:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:09:09 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 369.498 uV, v_off_fin = 340.877 uV 15:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.251 uVs 15:09:18 Integrated Voltage Measurement... 15:09:27 Voltage Offset Correction: v_off_ini = 363.753 uV, v_off_fin = 356.810 uV 15:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.785 uVs 15:09:27 Integrated Voltage Measurement... 15:09:36 Voltage Offset Correction: v_off_ini = 362.935 uV, v_off_fin = 352.114 uV 15:09:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.933 uVs 15:09:36 Integrated Voltage Measurement... 15:09:45 Voltage Offset Correction: v_off_ini = 381.432 uV, v_off_fin = 380.508 uV 15:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.132 uVs 15:09:45 Integrated Voltage Measurement... 15:09:54 Voltage Offset Correction: v_off_ini = 367.058 uV, v_off_fin = 366.886 uV 15:09:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.726 uVs 15:09:54 Integrated Voltage Measurement... 15:10:03 Voltage Offset Correction: v_off_ini = 377.593 uV, v_off_fin = 381.213 uV 15:10:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.654 uVs 15:10:08 I1X Average and RMS of Measurements VT = -78.747 +- 1.774 uVs I1X = 15.750 +- 0.354 uTm 15:10:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:10:14 Integrated Voltage Measurement... 15:10:23 Voltage Offset Correction: v_off_ini = 358.986 uV, v_off_fin = 352.722 uV 15:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.347 uVs 15:10:23 Integrated Voltage Measurement... 15:10:32 Voltage Offset Correction: v_off_ini = 369.315 uV, v_off_fin = 386.429 uV 15:10:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 138.580 uVs 15:10:32 Integrated Voltage Measurement... 15:10:41 Voltage Offset Correction: v_off_ini = 394.919 uV, v_off_fin = 372.717 uV 15:10:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.608 uVs 15:10:41 Integrated Voltage Measurement... 15:10:50 Voltage Offset Correction: v_off_ini = 384.522 uV, v_off_fin = 385.649 uV 15:10:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.997 uVs 15:10:50 Integrated Voltage Measurement... 15:10:59 Voltage Offset Correction: v_off_ini = 381.742 uV, v_off_fin = 370.832 uV 15:10:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.450 uVs 15:10:59 Integrated Voltage Measurement... 15:11:08 Voltage Offset Correction: v_off_ini = 380.903 uV, v_off_fin = 375.114 uV 15:11:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.538 uVs 15:11:13 I1Y Average and RMS of Measurements VT = -155.920 +- 13.120 uVs I1Y = -31.184 +- 2.624 uTm 15:11:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:11:20 Integrated Voltage Measurement... 15:11:29 Voltage Offset Correction: v_off_ini = 384.916 uV, v_off_fin = 362.920 uV 15:11:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.190 uVs 15:11:29 Integrated Voltage Measurement... 15:11:38 Voltage Offset Correction: v_off_ini = 381.411 uV, v_off_fin = 389.365 uV 15:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.908 uVs 15:11:38 Integrated Voltage Measurement... 15:11:47 Voltage Offset Correction: v_off_ini = 378.051 uV, v_off_fin = 384.196 uV 15:11:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.851 uVs 15:11:47 Integrated Voltage Measurement... 15:11:56 Voltage Offset Correction: v_off_ini = 384.881 uV, v_off_fin = 402.112 uV 15:11:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.023 uVs 15:11:56 Integrated Voltage Measurement... 15:12:05 Voltage Offset Correction: v_off_ini = 375.697 uV, v_off_fin = 355.284 uV 15:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.992 uVs 15:12:05 Integrated Voltage Measurement... 15:12:14 Voltage Offset Correction: v_off_ini = 365.610 uV, v_off_fin = 365.203 uV 15:12:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.447 uVs 15:12:17 I2X Average and RMS of Measurements VT = -69.235 +- 12.627 uVs I2X = 6.370 +- 1.162 uTm^2 15:12:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:12:24 Integrated Voltage Measurement... 15:12:33 Voltage Offset Correction: v_off_ini = 363.217 uV, v_off_fin = 406.190 uV 15:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.243 uVs 15:12:33 Integrated Voltage Measurement... 15:12:42 Voltage Offset Correction: v_off_ini = 402.234 uV, v_off_fin = 389.368 uV 15:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.682 uVs 15:12:42 Integrated Voltage Measurement... 15:12:51 Voltage Offset Correction: v_off_ini = 394.721 uV, v_off_fin = 370.968 uV 15:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.722 uVs 15:12:52 Integrated Voltage Measurement... 15:13:00 Voltage Offset Correction: v_off_ini = 406.467 uV, v_off_fin = 395.451 uV 15:13:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.058 uVs 15:13:01 Integrated Voltage Measurement... 15:13:09 Voltage Offset Correction: v_off_ini = 390.748 uV, v_off_fin = 398.920 uV 15:13:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.401 uVs 15:13:10 Integrated Voltage Measurement... 15:13:19 Voltage Offset Correction: v_off_ini = 405.108 uV, v_off_fin = 403.679 uV 15:13:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.705 uVs 15:13:21 I2Y Average and RMS of Measurements VT = -195.135 +- 3.742 uVs I2Y = -17.952 +- 0.344 uTm^2 15:13:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:30 Integrated Voltage Measurement... 15:13:39 Voltage Offset Correction: v_off_ini = 392.216 uV, v_off_fin = 389.769 uV 15:13:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.850 uVs 15:13:39 Integrated Voltage Measurement... 15:13:48 Voltage Offset Correction: v_off_ini = 377.492 uV, v_off_fin = 378.045 uV 15:13:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.043 uVs 15:13:48 Integrated Voltage Measurement... 15:13:57 Voltage Offset Correction: v_off_ini = 390.425 uV, v_off_fin = 398.365 uV 15:13:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.454 uVs 15:13:57 Integrated Voltage Measurement... 15:14:06 Voltage Offset Correction: v_off_ini = 393.322 uV, v_off_fin = 387.131 uV 15:14:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.877 uVs 15:14:06 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = 372.204 uV, v_off_fin = 372.299 uV 15:14:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.362 uVs 15:14:15 Integrated Voltage Measurement... 15:14:24 Voltage Offset Correction: v_off_ini = 371.513 uV, v_off_fin = 364.973 uV 15:14:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.143 uVs 15:14:28 I1X Average and RMS of Measurements VT = -62.288 +- 5.216 uVs I1X = 12.458 +- 1.043 uTm 15:14:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:35 Integrated Voltage Measurement... 15:14:44 Voltage Offset Correction: v_off_ini = 359.663 uV, v_off_fin = 365.521 uV 15:14:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.868 uVs 15:14:44 Integrated Voltage Measurement... 15:14:53 Voltage Offset Correction: v_off_ini = 362.917 uV, v_off_fin = 395.303 uV 15:14:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.405 uVs 15:14:53 Integrated Voltage Measurement... 15:15:02 Voltage Offset Correction: v_off_ini = 365.543 uV, v_off_fin = 378.668 uV 15:15:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.745 uVs 15:15:02 Integrated Voltage Measurement... 15:15:11 Voltage Offset Correction: v_off_ini = 365.310 uV, v_off_fin = 382.814 uV 15:15:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.051 uVs 15:15:11 Integrated Voltage Measurement... 15:15:20 Voltage Offset Correction: v_off_ini = 379.544 uV, v_off_fin = 370.493 uV 15:15:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.632 uVs 15:15:20 Integrated Voltage Measurement... 15:15:29 Voltage Offset Correction: v_off_ini = 359.405 uV, v_off_fin = 367.830 uV 15:15:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.780 uVs 15:15:33 I1Y Average and RMS of Measurements VT = -151.580 +- 2.545 uVs I1Y = -30.316 +- 0.509 uTm 15:15:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:41 Integrated Voltage Measurement... 15:15:50 Voltage Offset Correction: v_off_ini = 379.916 uV, v_off_fin = 367.225 uV 15:15:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -80.937 uVs 15:15:50 Integrated Voltage Measurement... 15:15:59 Voltage Offset Correction: v_off_ini = 381.891 uV, v_off_fin = 388.892 uV 15:15:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.469 uVs 15:15:59 Integrated Voltage Measurement... 15:16:08 Voltage Offset Correction: v_off_ini = 372.536 uV, v_off_fin = 364.782 uV 15:16:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.047 uVs 15:16:08 Integrated Voltage Measurement... 15:16:17 Voltage Offset Correction: v_off_ini = 380.916 uV, v_off_fin = 381.350 uV 15:16:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.844 uVs 15:16:17 Integrated Voltage Measurement... 15:16:26 Voltage Offset Correction: v_off_ini = 372.892 uV, v_off_fin = 364.129 uV 15:16:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.379 uVs 15:16:26 Integrated Voltage Measurement... 15:16:35 Voltage Offset Correction: v_off_ini = 366.777 uV, v_off_fin = 356.554 uV 15:16:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.153 uVs 15:16:37 I2X Average and RMS of Measurements VT = -66.805 +- 2.375 uVs I2X = 6.146 +- 0.219 uTm^2 15:16:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:45 Integrated Voltage Measurement... 15:16:54 Voltage Offset Correction: v_off_ini = 368.474 uV, v_off_fin = 377.509 uV 15:16:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.624 uVs 15:16:54 Integrated Voltage Measurement... 15:17:03 Voltage Offset Correction: v_off_ini = 374.319 uV, v_off_fin = 372.174 uV 15:17:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.652 uVs 15:17:03 Integrated Voltage Measurement... 15:17:12 Voltage Offset Correction: v_off_ini = 371.360 uV, v_off_fin = 364.750 uV 15:17:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.479 uVs 15:17:12 Integrated Voltage Measurement... 15:17:21 Voltage Offset Correction: v_off_ini = 380.079 uV, v_off_fin = 373.866 uV 15:17:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.960 uVs 15:17:21 Integrated Voltage Measurement... 15:17:30 Voltage Offset Correction: v_off_ini = 369.304 uV, v_off_fin = 366.059 uV 15:17:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.976 uVs 15:17:30 Integrated Voltage Measurement... 15:17:39 Voltage Offset Correction: v_off_ini = 371.743 uV, v_off_fin = 372.910 uV 15:17:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.643 uVs 15:17:41 I2Y Average and RMS of Measurements VT = -190.222 +- 4.952 uVs I2Y = -17.500 +- 0.456 uTm^2 15:17:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:17:50 Integrated Voltage Measurement... 15:17:59 Voltage Offset Correction: v_off_ini = 366.394 uV, v_off_fin = 364.804 uV 15:17:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.201 uVs 15:17:59 Integrated Voltage Measurement... 15:18:08 Voltage Offset Correction: v_off_ini = 364.557 uV, v_off_fin = 355.755 uV 15:18:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.462 uVs 15:18:08 Integrated Voltage Measurement... 15:18:17 Voltage Offset Correction: v_off_ini = 358.488 uV, v_off_fin = 357.534 uV 15:18:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.874 uVs 15:18:17 Integrated Voltage Measurement... 15:18:26 Voltage Offset Correction: v_off_ini = 367.896 uV, v_off_fin = 361.594 uV 15:18:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.542 uVs 15:18:26 Integrated Voltage Measurement... 15:18:35 Voltage Offset Correction: v_off_ini = 344.781 uV, v_off_fin = 332.758 uV 15:18:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.187 uVs 15:18:35 Integrated Voltage Measurement... 15:18:44 Voltage Offset Correction: v_off_ini = 350.957 uV, v_off_fin = 368.472 uV 15:18:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.339 uVs 15:18:49 I1X Average and RMS of Measurements VT = -46.101 +- 4.158 uVs I1X = 9.220 +- 0.831 uTm 15:18:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:18:55 Integrated Voltage Measurement... 15:19:04 Voltage Offset Correction: v_off_ini = 366.623 uV, v_off_fin = 345.905 uV 15:19:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -157.086 uVs 15:19:04 Integrated Voltage Measurement... 15:19:13 Voltage Offset Correction: v_off_ini = 349.401 uV, v_off_fin = 370.754 uV 15:19:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.308 uVs 15:19:13 Integrated Voltage Measurement... 15:19:22 Voltage Offset Correction: v_off_ini = 361.322 uV, v_off_fin = 347.445 uV 15:19:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.737 uVs 15:19:22 Integrated Voltage Measurement... 15:19:31 Voltage Offset Correction: v_off_ini = 375.194 uV, v_off_fin = 365.370 uV 15:19:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 143.233 uVs 15:19:31 Integrated Voltage Measurement... 15:19:40 Voltage Offset Correction: v_off_ini = 370.437 uV, v_off_fin = 373.319 uV 15:19:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.896 uVs 15:19:40 Integrated Voltage Measurement... 15:19:49 Voltage Offset Correction: v_off_ini = 361.562 uV, v_off_fin = 367.899 uV 15:19:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.179 uVs 15:19:53 I1Y Average and RMS of Measurements VT = -154.406 +- 1.062 uVs I1Y = -30.882 +- 0.213 uTm 15:19:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:20:01 Integrated Voltage Measurement... 15:20:10 Voltage Offset Correction: v_off_ini = 357.457 uV, v_off_fin = 348.046 uV 15:20:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -39.435 uVs 15:20:10 Integrated Voltage Measurement... 15:20:19 Voltage Offset Correction: v_off_ini = 352.987 uV, v_off_fin = 368.163 uV 15:20:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.298 uVs 15:20:19 Integrated Voltage Measurement... 15:20:28 Voltage Offset Correction: v_off_ini = 356.021 uV, v_off_fin = 334.402 uV 15:20:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.410 uVs 15:20:28 Integrated Voltage Measurement... 15:20:37 Voltage Offset Correction: v_off_ini = 343.225 uV, v_off_fin = 356.428 uV 15:20:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.399 uVs 15:20:37 Integrated Voltage Measurement... 15:20:46 Voltage Offset Correction: v_off_ini = 349.847 uV, v_off_fin = 331.524 uV 15:20:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.059 uVs 15:20:46 Integrated Voltage Measurement... 15:20:55 Voltage Offset Correction: v_off_ini = 349.704 uV, v_off_fin = 351.445 uV 15:20:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.127 uVs 15:20:58 I2X Average and RMS of Measurements VT = -39.621 +- 8.259 uVs I2X = 3.645 +- 0.760 uTm^2 15:21:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:21:05 Integrated Voltage Measurement... 15:21:14 Voltage Offset Correction: v_off_ini = 348.373 uV, v_off_fin = 349.222 uV 15:21:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.398 uVs 15:21:14 Integrated Voltage Measurement... 15:21:23 Voltage Offset Correction: v_off_ini = 339.142 uV, v_off_fin = 343.563 uV 15:21:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.756 uVs 15:21:23 Integrated Voltage Measurement... 15:21:32 Voltage Offset Correction: v_off_ini = 335.129 uV, v_off_fin = 358.512 uV 15:21:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.698 uVs 15:21:32 Integrated Voltage Measurement... 15:21:41 Voltage Offset Correction: v_off_ini = 352.555 uV, v_off_fin = 347.317 uV 15:21:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.205 uVs 15:21:41 Integrated Voltage Measurement... 15:21:50 Voltage Offset Correction: v_off_ini = 345.306 uV, v_off_fin = 350.004 uV 15:21:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.611 uVs 15:21:50 Integrated Voltage Measurement... 15:21:59 Voltage Offset Correction: v_off_ini = 346.370 uV, v_off_fin = 365.676 uV 15:21:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.778 uVs 15:22:02 I2Y Average and RMS of Measurements VT = -197.575 +- 4.244 uVs I2Y = -18.177 +- 0.390 uTm^2 15:22:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:22:11 Integrated Voltage Measurement... 15:22:20 Voltage Offset Correction: v_off_ini = 347.590 uV, v_off_fin = 343.198 uV 15:22:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.700 uVs 15:22:20 Integrated Voltage Measurement... 15:22:29 Voltage Offset Correction: v_off_ini = 356.023 uV, v_off_fin = 350.778 uV 15:22:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.116 uVs 15:22:29 Integrated Voltage Measurement... 15:22:38 Voltage Offset Correction: v_off_ini = 349.060 uV, v_off_fin = 343.562 uV 15:22:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.567 uVs 15:22:38 Integrated Voltage Measurement... 15:22:47 Voltage Offset Correction: v_off_ini = 355.550 uV, v_off_fin = 358.930 uV 15:22:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.528 uVs 15:22:47 Integrated Voltage Measurement... 15:22:56 Voltage Offset Correction: v_off_ini = 354.498 uV, v_off_fin = 345.854 uV 15:22:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.526 uVs 15:22:56 Integrated Voltage Measurement... 15:23:05 Voltage Offset Correction: v_off_ini = 353.915 uV, v_off_fin = 360.013 uV 15:23:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.541 uVs 15:23:09 I1X Average and RMS of Measurements VT = -36.996 +- 3.669 uVs I1X = 7.399 +- 0.734 uTm 15:23:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:23:16 Integrated Voltage Measurement... 15:23:25 Voltage Offset Correction: v_off_ini = 349.878 uV, v_off_fin = 348.069 uV 15:23:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.280 uVs 15:23:25 Integrated Voltage Measurement... 15:23:34 Voltage Offset Correction: v_off_ini = 345.736 uV, v_off_fin = 352.024 uV 15:23:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.528 uVs 15:23:34 Integrated Voltage Measurement... 15:23:43 Voltage Offset Correction: v_off_ini = 347.521 uV, v_off_fin = 361.507 uV 15:23:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.743 uVs 15:23:43 Integrated Voltage Measurement... 15:23:52 Voltage Offset Correction: v_off_ini = 366.333 uV, v_off_fin = 384.898 uV 15:23:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.517 uVs 15:23:52 Integrated Voltage Measurement... 15:24:01 Voltage Offset Correction: v_off_ini = 369.104 uV, v_off_fin = 349.832 uV 15:24:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.030 uVs 15:24:01 Integrated Voltage Measurement... 15:24:10 Voltage Offset Correction: v_off_ini = 365.454 uV, v_off_fin = 366.977 uV 15:24:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.369 uVs 15:24:14 I1Y Average and RMS of Measurements VT = -154.911 +- 7.737 uVs I1Y = -30.982 +- 1.547 uTm 15:24:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:24:22 Integrated Voltage Measurement... 15:24:31 Voltage Offset Correction: v_off_ini = 369.488 uV, v_off_fin = 372.322 uV 15:24:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -29.525 uVs 15:24:31 Integrated Voltage Measurement... 15:24:40 Voltage Offset Correction: v_off_ini = 366.439 uV, v_off_fin = 371.477 uV 15:24:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.162 uVs 15:24:40 Integrated Voltage Measurement... 15:24:49 Voltage Offset Correction: v_off_ini = 365.721 uV, v_off_fin = 345.481 uV 15:24:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.068 uVs 15:24:49 Integrated Voltage Measurement... 15:24:58 Voltage Offset Correction: v_off_ini = 366.579 uV, v_off_fin = 377.859 uV 15:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.492 uVs 15:24:58 Integrated Voltage Measurement... 15:25:07 Voltage Offset Correction: v_off_ini = 367.693 uV, v_off_fin = 364.047 uV 15:25:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.801 uVs 15:25:07 Integrated Voltage Measurement... 15:25:16 Voltage Offset Correction: v_off_ini = 372.235 uV, v_off_fin = 381.577 uV 15:25:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 23.955 uVs 15:25:18 I2X Average and RMS of Measurements VT = -37.334 +- 5.104 uVs I2X = 3.435 +- 0.469 uTm^2 15:25:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:25:26 Integrated Voltage Measurement... 15:25:35 Voltage Offset Correction: v_off_ini = 356.171 uV, v_off_fin = 356.158 uV 15:25:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.023 uVs 15:25:35 Integrated Voltage Measurement... 15:25:44 Voltage Offset Correction: v_off_ini = 361.481 uV, v_off_fin = 361.507 uV 15:25:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.751 uVs 15:25:44 Integrated Voltage Measurement... 15:25:53 Voltage Offset Correction: v_off_ini = 364.489 uV, v_off_fin = 362.786 uV 15:25:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.564 uVs 15:25:53 Integrated Voltage Measurement... 15:26:02 Voltage Offset Correction: v_off_ini = 352.792 uV, v_off_fin = 351.628 uV 15:26:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 186.497 uVs 15:26:02 Integrated Voltage Measurement... 15:26:11 Voltage Offset Correction: v_off_ini = 347.347 uV, v_off_fin = 341.567 uV 15:26:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.146 uVs 15:26:11 Integrated Voltage Measurement... 15:26:20 Voltage Offset Correction: v_off_ini = 331.029 uV, v_off_fin = 340.362 uV 15:26:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.836 uVs 15:26:22 I2Y Average and RMS of Measurements VT = -191.970 +- 4.581 uVs I2Y = -17.661 +- 0.421 uTm^2 15:26:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:26:34 Integrated Voltage Measurement... 15:26:43 Voltage Offset Correction: v_off_ini = 333.011 uV, v_off_fin = 327.940 uV 15:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.372 uVs 15:26:43 Integrated Voltage Measurement... 15:26:52 Voltage Offset Correction: v_off_ini = 305.468 uV, v_off_fin = 308.799 uV 15:26:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.283 uVs 15:26:52 Integrated Voltage Measurement... 15:27:01 Voltage Offset Correction: v_off_ini = 308.915 uV, v_off_fin = 328.466 uV 15:27:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.144 uVs 15:27:01 Integrated Voltage Measurement... 15:27:10 Voltage Offset Correction: v_off_ini = 338.951 uV, v_off_fin = 335.205 uV 15:27:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.052 uVs 15:27:10 Integrated Voltage Measurement... 15:27:19 Voltage Offset Correction: v_off_ini = 341.911 uV, v_off_fin = 332.709 uV 15:27:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.927 uVs 15:27:19 Integrated Voltage Measurement... 15:27:28 Voltage Offset Correction: v_off_ini = 334.642 uV, v_off_fin = 324.636 uV 15:27:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.976 uVs 15:27:32 I1X Average and RMS of Measurements VT = -57.626 +- 14.229 uVs I1X = 11.525 +- 2.846 uTm 15:27:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:27:39 Integrated Voltage Measurement... 15:27:48 Voltage Offset Correction: v_off_ini = 341.461 uV, v_off_fin = 333.864 uV 15:27:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.712 uVs 15:27:48 Integrated Voltage Measurement... 15:27:57 Voltage Offset Correction: v_off_ini = 329.285 uV, v_off_fin = 341.470 uV 15:27:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.340 uVs 15:27:57 Integrated Voltage Measurement... 15:28:06 Voltage Offset Correction: v_off_ini = 333.861 uV, v_off_fin = 342.568 uV 15:28:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.341 uVs 15:28:06 Integrated Voltage Measurement... 15:28:15 Voltage Offset Correction: v_off_ini = 330.699 uV, v_off_fin = 354.798 uV 15:28:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.842 uVs 15:28:15 Integrated Voltage Measurement... 15:28:24 Voltage Offset Correction: v_off_ini = 344.962 uV, v_off_fin = 311.515 uV 15:28:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.936 uVs 15:28:24 Integrated Voltage Measurement... 15:28:33 Voltage Offset Correction: v_off_ini = 313.641 uV, v_off_fin = 329.056 uV 15:28:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.269 uVs 15:28:37 I1Y Average and RMS of Measurements VT = -172.240 +- 11.570 uVs I1Y = -34.449 +- 2.315 uTm 15:28:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:28:42 Integrated Voltage Measurement... 15:28:51 Voltage Offset Correction: v_off_ini = 314.381 uV, v_off_fin = 311.836 uV 15:28:51 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -40.434 uVs 15:28:51 Integrated Voltage Measurement... 15:29:00 Voltage Offset Correction: v_off_ini = 330.386 uV, v_off_fin = 313.352 uV 15:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.019 uVs 15:29:00 Integrated Voltage Measurement... 15:29:09 Voltage Offset Correction: v_off_ini = 326.815 uV, v_off_fin = 314.013 uV 15:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.990 uVs 15:29:09 Integrated Voltage Measurement... 15:29:18 Voltage Offset Correction: v_off_ini = 332.024 uV, v_off_fin = 330.498 uV 15:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.363 uVs 15:29:19 Integrated Voltage Measurement... 15:29:27 Voltage Offset Correction: v_off_ini = 332.345 uV, v_off_fin = 318.173 uV 15:29:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.410 uVs 15:29:28 Integrated Voltage Measurement... 15:29:36 Voltage Offset Correction: v_off_ini = 333.060 uV, v_off_fin = 330.438 uV 15:29:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.512 uVs 15:29:39 I2X Average and RMS of Measurements VT = -51.955 +- 5.544 uVs I2X = 4.780 +- 0.510 uTm^2 15:29:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:29:44 Integrated Voltage Measurement... 15:29:53 Voltage Offset Correction: v_off_ini = 333.614 uV, v_off_fin = 321.033 uV 15:29:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.336 uVs 15:29:53 Integrated Voltage Measurement... 15:30:02 Voltage Offset Correction: v_off_ini = 327.752 uV, v_off_fin = 335.773 uV 15:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.251 uVs 15:30:02 Integrated Voltage Measurement... 15:30:11 Voltage Offset Correction: v_off_ini = 324.223 uV, v_off_fin = 323.788 uV 15:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.024 uVs 15:30:11 Integrated Voltage Measurement... 15:30:20 Voltage Offset Correction: v_off_ini = 327.920 uV, v_off_fin = 331.868 uV 15:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.947 uVs 15:30:20 Integrated Voltage Measurement... 15:30:29 Voltage Offset Correction: v_off_ini = 330.291 uV, v_off_fin = 321.491 uV 15:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.560 uVs 15:30:29 Integrated Voltage Measurement... 15:30:38 Voltage Offset Correction: v_off_ini = 324.377 uV, v_off_fin = 316.362 uV 15:30:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.853 uVs 15:30:41 I2Y Average and RMS of Measurements VT = -207.995 +- 10.558 uVs I2Y = -19.136 +- 0.971 uTm^2 15:30:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:30:49 Integrated Voltage Measurement... 15:30:58 Voltage Offset Correction: v_off_ini = 347.062 uV, v_off_fin = 332.209 uV 15:30:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -62.429 uVs 15:30:58 Integrated Voltage Measurement... 15:31:07 Voltage Offset Correction: v_off_ini = 328.856 uV, v_off_fin = 344.585 uV 15:31:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.410 uVs 15:31:07 Integrated Voltage Measurement... 15:31:16 Voltage Offset Correction: v_off_ini = 340.926 uV, v_off_fin = 323.774 uV 15:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.382 uVs 15:31:16 Integrated Voltage Measurement... 15:31:25 Voltage Offset Correction: v_off_ini = 328.157 uV, v_off_fin = 325.731 uV 15:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.051 uVs 15:31:25 Integrated Voltage Measurement... 15:31:34 Voltage Offset Correction: v_off_ini = 331.233 uV, v_off_fin = 345.234 uV 15:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.238 uVs 15:31:34 Integrated Voltage Measurement... 15:31:43 Voltage Offset Correction: v_off_ini = 357.841 uV, v_off_fin = 347.784 uV 15:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.499 uVs 15:31:47 I1X Average and RMS of Measurements VT = -56.335 +- 7.170 uVs I1X = 11.268 +- 1.434 uTm 15:31:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:31:54 Integrated Voltage Measurement... 15:32:03 Voltage Offset Correction: v_off_ini = 344.337 uV, v_off_fin = 325.304 uV 15:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.430 uVs 15:32:03 Integrated Voltage Measurement... 15:32:12 Voltage Offset Correction: v_off_ini = 337.788 uV, v_off_fin = 354.608 uV 15:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.779 uVs 15:32:12 Integrated Voltage Measurement... 15:32:21 Voltage Offset Correction: v_off_ini = 337.435 uV, v_off_fin = 340.800 uV 15:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.451 uVs 15:32:21 Integrated Voltage Measurement... 15:32:30 Voltage Offset Correction: v_off_ini = 366.294 uV, v_off_fin = 377.266 uV 15:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.283 uVs 15:32:30 Integrated Voltage Measurement... 15:32:39 Voltage Offset Correction: v_off_ini = 359.795 uV, v_off_fin = 358.877 uV 15:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.990 uVs 15:32:39 Integrated Voltage Measurement... 15:32:48 Voltage Offset Correction: v_off_ini = 352.379 uV, v_off_fin = 352.200 uV 15:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.719 uVs 15:32:52 I1Y Average and RMS of Measurements VT = -160.275 +- 2.638 uVs I1Y = -32.055 +- 0.528 uTm 15:32:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:32:57 Integrated Voltage Measurement... 15:33:06 Voltage Offset Correction: v_off_ini = 349.748 uV, v_off_fin = 350.269 uV 15:33:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.881 uVs 15:33:06 Integrated Voltage Measurement... 15:33:15 Voltage Offset Correction: v_off_ini = 357.043 uV, v_off_fin = 390.801 uV 15:33:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.677 uVs 15:33:15 Integrated Voltage Measurement... 15:33:24 Voltage Offset Correction: v_off_ini = 383.418 uV, v_off_fin = 344.378 uV 15:33:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.962 uVs 15:33:24 Integrated Voltage Measurement... 15:33:33 Voltage Offset Correction: v_off_ini = 351.442 uV, v_off_fin = 373.937 uV 15:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.497 uVs 15:33:33 Integrated Voltage Measurement... 15:33:42 Voltage Offset Correction: v_off_ini = 355.499 uV, v_off_fin = 351.886 uV 15:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.403 uVs 15:33:42 Integrated Voltage Measurement... 15:33:51 Voltage Offset Correction: v_off_ini = 361.835 uV, v_off_fin = 378.243 uV 15:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.704 uVs 15:33:54 I2X Average and RMS of Measurements VT = -53.687 +- 4.920 uVs I2X = 4.939 +- 0.453 uTm^2 15:33:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:33:59 Integrated Voltage Measurement... 15:34:08 Voltage Offset Correction: v_off_ini = 365.621 uV, v_off_fin = 366.293 uV 15:34:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.932 uVs 15:34:08 Integrated Voltage Measurement... 15:34:17 Voltage Offset Correction: v_off_ini = 361.110 uV, v_off_fin = 352.402 uV 15:34:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.903 uVs 15:34:17 Integrated Voltage Measurement... 15:34:26 Voltage Offset Correction: v_off_ini = 364.877 uV, v_off_fin = 347.102 uV 15:34:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.569 uVs 15:34:26 Integrated Voltage Measurement... 15:34:35 Voltage Offset Correction: v_off_ini = 376.514 uV, v_off_fin = 368.220 uV 15:34:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.808 uVs 15:34:35 Integrated Voltage Measurement... 15:34:44 Voltage Offset Correction: v_off_ini = 392.708 uV, v_off_fin = 382.986 uV 15:34:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -224.093 uVs 15:34:44 Integrated Voltage Measurement... 15:34:53 Voltage Offset Correction: v_off_ini = 374.300 uV, v_off_fin = 379.012 uV 15:34:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.123 uVs 15:34:55 I2Y Average and RMS of Measurements VT = -201.905 +- 10.208 uVs I2Y = -18.576 +- 0.940 uTm^2 15:34:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:04 Integrated Voltage Measurement... 15:35:13 Voltage Offset Correction: v_off_ini = 369.692 uV, v_off_fin = 369.085 uV 15:35:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.059 uVs 15:35:13 Integrated Voltage Measurement... 15:35:22 Voltage Offset Correction: v_off_ini = 366.323 uV, v_off_fin = 382.772 uV 15:35:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.887 uVs 15:35:22 Integrated Voltage Measurement... 15:35:31 Voltage Offset Correction: v_off_ini = 378.442 uV, v_off_fin = 389.746 uV 15:35:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.215 uVs 15:35:31 Integrated Voltage Measurement... 15:35:40 Voltage Offset Correction: v_off_ini = 394.253 uV, v_off_fin = 380.913 uV 15:35:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.202 uVs 15:35:40 Integrated Voltage Measurement... 15:35:49 Voltage Offset Correction: v_off_ini = 387.101 uV, v_off_fin = 377.210 uV 15:35:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.151 uVs 15:35:49 Integrated Voltage Measurement... 15:35:58 Voltage Offset Correction: v_off_ini = 378.790 uV, v_off_fin = 387.664 uV 15:35:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.636 uVs 15:36:02 I1X Average and RMS of Measurements VT = -56.025 +- 6.985 uVs I1X = 11.205 +- 1.397 uTm 15:36:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:09 Integrated Voltage Measurement... 15:36:17 Voltage Offset Correction: v_off_ini = 390.728 uV, v_off_fin = 378.087 uV 15:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.314 uVs 15:36:18 Integrated Voltage Measurement... 15:36:26 Voltage Offset Correction: v_off_ini = 391.544 uV, v_off_fin = 410.162 uV 15:36:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.827 uVs 15:36:27 Integrated Voltage Measurement... 15:36:35 Voltage Offset Correction: v_off_ini = 379.032 uV, v_off_fin = 371.774 uV 15:36:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.218 uVs 15:36:36 Integrated Voltage Measurement... 15:36:44 Voltage Offset Correction: v_off_ini = 371.938 uV, v_off_fin = 403.888 uV 15:36:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.210 uVs 15:36:45 Integrated Voltage Measurement... 15:36:53 Voltage Offset Correction: v_off_ini = 374.766 uV, v_off_fin = 367.446 uV 15:36:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.068 uVs 15:36:53 Integrated Voltage Measurement... 15:37:02 Voltage Offset Correction: v_off_ini = 382.403 uV, v_off_fin = 387.021 uV 15:37:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.723 uVs 15:37:07 I1Y Average and RMS of Measurements VT = -162.060 +- 5.653 uVs I1Y = -32.413 +- 1.130 uTm 15:37:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:12 Integrated Voltage Measurement... 15:37:21 Voltage Offset Correction: v_off_ini = 390.247 uV, v_off_fin = 389.046 uV 15:37:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.466 uVs 15:37:21 Integrated Voltage Measurement... 15:37:30 Voltage Offset Correction: v_off_ini = 399.565 uV, v_off_fin = 409.120 uV 15:37:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.910 uVs 15:37:30 Integrated Voltage Measurement... 15:37:39 Voltage Offset Correction: v_off_ini = 409.693 uV, v_off_fin = 399.334 uV 15:37:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.567 uVs 15:37:39 Integrated Voltage Measurement... 15:37:48 Voltage Offset Correction: v_off_ini = 407.039 uV, v_off_fin = 410.403 uV 15:37:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.805 uVs 15:37:48 Integrated Voltage Measurement... 15:37:57 Voltage Offset Correction: v_off_ini = 399.105 uV, v_off_fin = 389.275 uV 15:37:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.816 uVs 15:37:57 Integrated Voltage Measurement... 15:38:06 Voltage Offset Correction: v_off_ini = 381.030 uV, v_off_fin = 396.111 uV 15:38:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.161 uVs 15:38:08 I2X Average and RMS of Measurements VT = -54.121 +- 4.169 uVs I2X = 4.979 +- 0.384 uTm^2 15:38:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:13 Integrated Voltage Measurement... 15:38:22 Voltage Offset Correction: v_off_ini = 384.987 uV, v_off_fin = 395.278 uV 15:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.500 uVs 15:38:22 Integrated Voltage Measurement... 15:38:31 Voltage Offset Correction: v_off_ini = 378.390 uV, v_off_fin = 389.129 uV 15:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.132 uVs 15:38:31 Integrated Voltage Measurement... 15:38:40 Voltage Offset Correction: v_off_ini = 374.783 uV, v_off_fin = 376.630 uV 15:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.392 uVs 15:38:40 Integrated Voltage Measurement... 15:38:49 Voltage Offset Correction: v_off_ini = 373.229 uV, v_off_fin = 371.957 uV 15:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.676 uVs 15:38:50 Integrated Voltage Measurement... 15:38:58 Voltage Offset Correction: v_off_ini = 367.076 uV, v_off_fin = 375.904 uV 15:38:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.490 uVs 15:38:59 Integrated Voltage Measurement... 15:39:08 Voltage Offset Correction: v_off_ini = 375.070 uV, v_off_fin = 373.297 uV 15:39:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.920 uVs 15:39:10 I2Y Average and RMS of Measurements VT = -195.852 +- 6.055 uVs I2Y = -18.018 +- 0.557 uTm^2 15:39:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:39:18 Integrated Voltage Measurement... 15:39:27 Voltage Offset Correction: v_off_ini = 399.058 uV, v_off_fin = 388.188 uV 15:39:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.673 uVs 15:39:27 Integrated Voltage Measurement... 15:39:36 Voltage Offset Correction: v_off_ini = 401.797 uV, v_off_fin = 398.501 uV 15:39:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.586 uVs 15:39:36 Integrated Voltage Measurement... 15:39:45 Voltage Offset Correction: v_off_ini = 395.606 uV, v_off_fin = 369.422 uV 15:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.958 uVs 15:39:45 Integrated Voltage Measurement... 15:39:54 Voltage Offset Correction: v_off_ini = 411.393 uV, v_off_fin = 401.527 uV 15:39:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.528 uVs 15:39:54 Integrated Voltage Measurement... 15:40:03 Voltage Offset Correction: v_off_ini = 389.673 uV, v_off_fin = 388.612 uV 15:40:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.662 uVs 15:40:03 Integrated Voltage Measurement... 15:40:12 Voltage Offset Correction: v_off_ini = 377.225 uV, v_off_fin = 385.040 uV 15:40:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.473 uVs 15:40:16 I1X Average and RMS of Measurements VT = -50.647 +- 8.897 uVs I1X = 10.129 +- 1.779 uTm 15:40:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:40:23 Integrated Voltage Measurement... 15:40:32 Voltage Offset Correction: v_off_ini = 396.605 uV, v_off_fin = 379.179 uV 15:40:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -142.232 uVs 15:40:32 Integrated Voltage Measurement... 15:40:41 Voltage Offset Correction: v_off_ini = 381.338 uV, v_off_fin = 379.077 uV 15:40:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 135.345 uVs 15:40:41 Integrated Voltage Measurement... 15:40:50 Voltage Offset Correction: v_off_ini = 370.241 uV, v_off_fin = 359.455 uV 15:40:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -138.227 uVs 15:40:50 Integrated Voltage Measurement... 15:40:59 Voltage Offset Correction: v_off_ini = 373.307 uV, v_off_fin = 375.564 uV 15:40:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 168.372 uVs 15:40:59 Integrated Voltage Measurement... 15:41:08 Voltage Offset Correction: v_off_ini = 366.313 uV, v_off_fin = 359.368 uV 15:41:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -139.462 uVs 15:41:08 Integrated Voltage Measurement... 15:41:17 Voltage Offset Correction: v_off_ini = 386.413 uV, v_off_fin = 371.954 uV 15:41:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 138.899 uVs 15:41:21 I1Y Average and RMS of Measurements VT = -143.756 +- 6.750 uVs I1Y = -28.749 +- 1.349 uTm 15:41:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:41:26 Integrated Voltage Measurement... 15:41:35 Voltage Offset Correction: v_off_ini = 374.243 uV, v_off_fin = 367.274 uV 15:41:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -67.044 uVs 15:41:36 Integrated Voltage Measurement... 15:41:44 Voltage Offset Correction: v_off_ini = 363.828 uV, v_off_fin = 366.960 uV 15:41:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.431 uVs 15:41:45 Integrated Voltage Measurement... 15:41:54 Voltage Offset Correction: v_off_ini = 359.718 uV, v_off_fin = 346.136 uV 15:41:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.755 uVs 15:41:54 Integrated Voltage Measurement... 15:42:03 Voltage Offset Correction: v_off_ini = 356.813 uV, v_off_fin = 375.737 uV 15:42:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.342 uVs 15:42:03 Integrated Voltage Measurement... 15:42:12 Voltage Offset Correction: v_off_ini = 343.795 uV, v_off_fin = 338.430 uV 15:42:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.168 uVs 15:42:12 Integrated Voltage Measurement... 15:42:21 Voltage Offset Correction: v_off_ini = 369.475 uV, v_off_fin = 365.827 uV 15:42:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.983 uVs 15:42:23 I2X Average and RMS of Measurements VT = -55.121 +- 12.110 uVs I2X = 5.071 +- 1.114 uTm^2 15:42:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:42:28 Integrated Voltage Measurement... 15:42:37 Voltage Offset Correction: v_off_ini = 351.010 uV, v_off_fin = 348.776 uV 15:42:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.184 uVs 15:42:37 Integrated Voltage Measurement... 15:42:46 Voltage Offset Correction: v_off_ini = 349.456 uV, v_off_fin = 348.456 uV 15:42:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 164.120 uVs 15:42:46 Integrated Voltage Measurement... 15:42:55 Voltage Offset Correction: v_off_ini = 336.743 uV, v_off_fin = 330.779 uV 15:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.726 uVs 15:42:55 Integrated Voltage Measurement... 15:43:04 Voltage Offset Correction: v_off_ini = 323.663 uV, v_off_fin = 331.431 uV 15:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.346 uVs 15:43:04 Integrated Voltage Measurement... 15:43:13 Voltage Offset Correction: v_off_ini = 334.322 uV, v_off_fin = 350.309 uV 15:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.971 uVs 15:43:14 Integrated Voltage Measurement... 15:43:22 Voltage Offset Correction: v_off_ini = 333.207 uV, v_off_fin = 325.290 uV 15:43:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.113 uVs 15:43:25 I2Y Average and RMS of Measurements VT = -186.243 +- 6.075 uVs I2Y = -17.134 +- 0.559 uTm^2 15:43:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:43:33 Integrated Voltage Measurement... 15:43:42 Voltage Offset Correction: v_off_ini = 317.338 uV, v_off_fin = 325.960 uV 15:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.661 uVs 15:43:42 Integrated Voltage Measurement... 15:43:51 Voltage Offset Correction: v_off_ini = 325.169 uV, v_off_fin = 324.960 uV 15:43:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.768 uVs 15:43:51 Integrated Voltage Measurement... 15:44:00 Voltage Offset Correction: v_off_ini = 335.329 uV, v_off_fin = 308.326 uV 15:44:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.823 uVs 15:44:00 Integrated Voltage Measurement... 15:44:09 Voltage Offset Correction: v_off_ini = 334.156 uV, v_off_fin = 330.216 uV 15:44:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.177 uVs 15:44:09 Integrated Voltage Measurement... 15:44:18 Voltage Offset Correction: v_off_ini = 327.042 uV, v_off_fin = 331.151 uV 15:44:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.705 uVs 15:44:18 Integrated Voltage Measurement... 15:44:27 Voltage Offset Correction: v_off_ini = 324.747 uV, v_off_fin = 338.480 uV 15:44:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.785 uVs 15:44:32 I1X Average and RMS of Measurements VT = -49.487 +- 5.411 uVs I1X = 9.897 +- 1.082 uTm 15:44:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:44:38 Integrated Voltage Measurement... 15:44:47 Voltage Offset Correction: v_off_ini = 338.009 uV, v_off_fin = 337.100 uV 15:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -125.003 uVs 15:44:47 Integrated Voltage Measurement... 15:44:56 Voltage Offset Correction: v_off_ini = 335.107 uV, v_off_fin = 349.091 uV 15:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 128.999 uVs 15:44:56 Integrated Voltage Measurement... 15:45:05 Voltage Offset Correction: v_off_ini = 336.338 uV, v_off_fin = 336.986 uV 15:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -114.223 uVs 15:45:05 Integrated Voltage Measurement... 15:45:14 Voltage Offset Correction: v_off_ini = 343.877 uV, v_off_fin = 354.272 uV 15:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 148.192 uVs 15:45:15 Integrated Voltage Measurement... 15:45:23 Voltage Offset Correction: v_off_ini = 340.650 uV, v_off_fin = 326.266 uV 15:45:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -131.398 uVs 15:45:24 Integrated Voltage Measurement... 15:45:32 Voltage Offset Correction: v_off_ini = 326.447 uV, v_off_fin = 347.459 uV 15:45:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 135.715 uVs 15:45:37 I1Y Average and RMS of Measurements VT = -130.588 +- 2.712 uVs I1Y = -26.116 +- 0.541 uTm 15:45:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:45:42 Integrated Voltage Measurement... 15:45:51 Voltage Offset Correction: v_off_ini = 347.321 uV, v_off_fin = 320.574 uV 15:45:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.773 uVs 15:45:51 Integrated Voltage Measurement... 15:46:00 Voltage Offset Correction: v_off_ini = 347.223 uV, v_off_fin = 359.741 uV 15:46:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.734 uVs 15:46:00 Integrated Voltage Measurement... 15:46:09 Voltage Offset Correction: v_off_ini = 341.688 uV, v_off_fin = 330.033 uV 15:46:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.949 uVs 15:46:09 Integrated Voltage Measurement... 15:46:18 Voltage Offset Correction: v_off_ini = 338.056 uV, v_off_fin = 355.808 uV 15:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.678 uVs 15:46:18 Integrated Voltage Measurement... 15:46:27 Voltage Offset Correction: v_off_ini = 349.899 uV, v_off_fin = 346.868 uV 15:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.447 uVs 15:46:27 Integrated Voltage Measurement... 15:46:36 Voltage Offset Correction: v_off_ini = 346.807 uV, v_off_fin = 365.784 uV 15:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.378 uVs 15:46:38 I2X Average and RMS of Measurements VT = -46.493 +- 2.931 uVs I2X = 4.277 +- 0.270 uTm^2 15:46:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:46:44 Integrated Voltage Measurement... 15:46:53 Voltage Offset Correction: v_off_ini = 354.090 uV, v_off_fin = 326.621 uV 15:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.575 uVs 15:46:53 Integrated Voltage Measurement... 15:47:02 Voltage Offset Correction: v_off_ini = 352.660 uV, v_off_fin = 366.893 uV 15:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.424 uVs 15:47:02 Integrated Voltage Measurement... 15:47:11 Voltage Offset Correction: v_off_ini = 365.094 uV, v_off_fin = 343.456 uV 15:47:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.547 uVs 15:47:11 Integrated Voltage Measurement... 15:47:20 Voltage Offset Correction: v_off_ini = 346.644 uV, v_off_fin = 334.998 uV 15:47:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.129 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 332.086 uV, v_off_fin = 341.014 uV 15:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.714 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 358.149 uV, v_off_fin = 353.208 uV 15:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.085 uVs 15:47:40 I2Y Average and RMS of Measurements VT = -174.746 +- 4.067 uVs I2Y = -16.077 +- 0.374 uTm^2 15:47:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:48:00 Integrated Voltage Measurement... 15:48:09 Voltage Offset Correction: v_off_ini = 362.374 uV, v_off_fin = 359.725 uV 15:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.555 uVs 15:48:09 Integrated Voltage Measurement... 15:48:18 Voltage Offset Correction: v_off_ini = 358.125 uV, v_off_fin = 379.770 uV 15:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.898 uVs 15:48:18 Integrated Voltage Measurement... 15:48:27 Voltage Offset Correction: v_off_ini = 373.640 uV, v_off_fin = 383.306 uV 15:48:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.129 uVs 15:48:27 Integrated Voltage Measurement... 15:48:36 Voltage Offset Correction: v_off_ini = 378.010 uV, v_off_fin = 394.686 uV 15:48:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.777 uVs 15:48:36 Integrated Voltage Measurement... 15:48:45 Voltage Offset Correction: v_off_ini = 409.000 uV, v_off_fin = 376.972 uV 15:48:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.583 uVs 15:48:45 Integrated Voltage Measurement... 15:48:54 Voltage Offset Correction: v_off_ini = 377.491 uV, v_off_fin = 383.919 uV 15:48:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.433 uVs 15:48:59 I1X Average and RMS of Measurements VT = -115.063 +- 8.329 uVs I1X = 23.013 +- 1.666 uTm 15:49:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:49:05 Integrated Voltage Measurement... 15:49:14 Voltage Offset Correction: v_off_ini = 364.873 uV, v_off_fin = 374.522 uV 15:49:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -187.332 uVs 15:49:14 Integrated Voltage Measurement... 15:49:23 Voltage Offset Correction: v_off_ini = 381.448 uV, v_off_fin = 385.498 uV 15:49:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.148 uVs 15:49:23 Integrated Voltage Measurement... 15:49:32 Voltage Offset Correction: v_off_ini = 392.033 uV, v_off_fin = 360.369 uV 15:49:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.141 uVs 15:49:32 Integrated Voltage Measurement... 15:49:41 Voltage Offset Correction: v_off_ini = 393.974 uV, v_off_fin = 392.589 uV 15:49:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.428 uVs 15:49:41 Integrated Voltage Measurement... 15:49:50 Voltage Offset Correction: v_off_ini = 392.143 uV, v_off_fin = 382.065 uV 15:49:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.592 uVs 15:49:50 Integrated Voltage Measurement... 15:49:59 Voltage Offset Correction: v_off_ini = 384.113 uV, v_off_fin = 405.615 uV 15:49:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.454 uVs 15:50:04 I1Y Average and RMS of Measurements VT = -184.182 +- 3.613 uVs I1Y = -36.837 +- 0.724 uTm 15:50:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:50:11 Integrated Voltage Measurement... 15:50:20 Voltage Offset Correction: v_off_ini = 361.063 uV, v_off_fin = 375.889 uV 15:50:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.074 uVs 15:50:20 Integrated Voltage Measurement... 15:50:29 Voltage Offset Correction: v_off_ini = 376.102 uV, v_off_fin = 388.153 uV 15:50:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.318 uVs 15:50:30 Integrated Voltage Measurement... 15:50:38 Voltage Offset Correction: v_off_ini = 390.776 uV, v_off_fin = 373.120 uV 15:50:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.493 uVs 15:50:39 Integrated Voltage Measurement... 15:50:47 Voltage Offset Correction: v_off_ini = 386.616 uV, v_off_fin = 401.549 uV 15:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.102 uVs 15:50:48 Integrated Voltage Measurement... 15:50:57 Voltage Offset Correction: v_off_ini = 376.962 uV, v_off_fin = 388.246 uV 15:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.954 uVs 15:50:57 Integrated Voltage Measurement... 15:51:06 Voltage Offset Correction: v_off_ini = 388.301 uV, v_off_fin = 387.494 uV 15:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.736 uVs 15:51:08 I2X Average and RMS of Measurements VT = -113.780 +- 6.621 uVs I2X = 10.468 +- 0.609 uTm^2 15:51:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:51:16 Integrated Voltage Measurement... 15:51:25 Voltage Offset Correction: v_off_ini = 380.096 uV, v_off_fin = 401.489 uV 15:51:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.325 uVs 15:51:25 Integrated Voltage Measurement... 15:51:34 Voltage Offset Correction: v_off_ini = 402.533 uV, v_off_fin = 395.238 uV 15:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.045 uVs 15:51:34 Integrated Voltage Measurement... 15:51:43 Voltage Offset Correction: v_off_ini = 398.851 uV, v_off_fin = 397.445 uV 15:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.720 uVs 15:51:43 Integrated Voltage Measurement... 15:51:52 Voltage Offset Correction: v_off_ini = 404.162 uV, v_off_fin = 380.058 uV 15:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.879 uVs 15:51:52 Integrated Voltage Measurement... 15:52:01 Voltage Offset Correction: v_off_ini = 389.159 uV, v_off_fin = 401.077 uV 15:52:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.349 uVs 15:52:01 Integrated Voltage Measurement... 15:52:10 Voltage Offset Correction: v_off_ini = 386.820 uV, v_off_fin = 388.518 uV 15:52:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 194.863 uVs 15:52:12 I2Y Average and RMS of Measurements VT = -213.697 +- 3.821 uVs I2Y = -19.660 +- 0.351 uTm^2 15:52:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:52:21 Integrated Voltage Measurement... 15:52:30 Voltage Offset Correction: v_off_ini = 399.618 uV, v_off_fin = 390.942 uV 15:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.846 uVs 15:52:30 Integrated Voltage Measurement... 15:52:39 Voltage Offset Correction: v_off_ini = 383.968 uV, v_off_fin = 376.355 uV 15:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.960 uVs 15:52:39 Integrated Voltage Measurement... 15:52:48 Voltage Offset Correction: v_off_ini = 374.376 uV, v_off_fin = 399.037 uV 15:52:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.436 uVs 15:52:48 Integrated Voltage Measurement... 15:52:57 Voltage Offset Correction: v_off_ini = 375.949 uV, v_off_fin = 377.637 uV 15:52:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.658 uVs 15:52:57 Integrated Voltage Measurement... 15:53:06 Voltage Offset Correction: v_off_ini = 387.709 uV, v_off_fin = 377.959 uV 15:53:06 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -77.645 uVs 15:53:06 Integrated Voltage Measurement... 15:53:15 Voltage Offset Correction: v_off_ini = 375.040 uV, v_off_fin = 378.217 uV 15:53:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.672 uVs 15:53:20 I1X Average and RMS of Measurements VT = -87.703 +- 4.760 uVs I1X = 17.541 +- 0.952 uTm 15:53:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:53:26 Integrated Voltage Measurement... 15:53:35 Voltage Offset Correction: v_off_ini = 385.762 uV, v_off_fin = 385.417 uV 15:53:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.422 uVs 15:53:35 Integrated Voltage Measurement... 15:53:44 Voltage Offset Correction: v_off_ini = 407.226 uV, v_off_fin = 404.544 uV 15:53:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.064 uVs 15:53:44 Integrated Voltage Measurement... 15:53:53 Voltage Offset Correction: v_off_ini = 408.916 uV, v_off_fin = 373.919 uV 15:53:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.793 uVs 15:53:53 Integrated Voltage Measurement... 15:54:02 Voltage Offset Correction: v_off_ini = 400.914 uV, v_off_fin = 406.199 uV 15:54:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.711 uVs 15:54:02 Integrated Voltage Measurement... 15:54:11 Voltage Offset Correction: v_off_ini = 406.560 uV, v_off_fin = 420.626 uV 15:54:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.601 uVs 15:54:11 Integrated Voltage Measurement... 15:54:20 Voltage Offset Correction: v_off_ini = 408.245 uV, v_off_fin = 408.224 uV 15:54:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.059 uVs 15:54:25 I1Y Average and RMS of Measurements VT = -176.275 +- 5.697 uVs I1Y = -35.255 +- 1.139 uTm 15:54:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:54:32 Integrated Voltage Measurement... 15:54:41 Voltage Offset Correction: v_off_ini = 394.722 uV, v_off_fin = 376.162 uV 15:54:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.540 uVs 15:54:41 Integrated Voltage Measurement... 15:54:50 Voltage Offset Correction: v_off_ini = 396.289 uV, v_off_fin = 394.566 uV 15:54:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.329 uVs 15:54:50 Integrated Voltage Measurement... 15:54:59 Voltage Offset Correction: v_off_ini = 376.994 uV, v_off_fin = 377.290 uV 15:54:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.576 uVs 15:54:59 Integrated Voltage Measurement... 15:55:08 Voltage Offset Correction: v_off_ini = 381.451 uV, v_off_fin = 397.974 uV 15:55:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.995 uVs 15:55:08 Integrated Voltage Measurement... 15:55:17 Voltage Offset Correction: v_off_ini = 393.368 uV, v_off_fin = 368.159 uV 15:55:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.553 uVs 15:55:18 Integrated Voltage Measurement... 15:55:27 Voltage Offset Correction: v_off_ini = 388.324 uV, v_off_fin = 390.589 uV 15:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.403 uVs 15:55:29 I2X Average and RMS of Measurements VT = -86.566 +- 0.932 uVs I2X = 7.964 +- 0.086 uTm^2 15:55:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:55:37 Integrated Voltage Measurement... 15:55:46 Voltage Offset Correction: v_off_ini = 373.294 uV, v_off_fin = 389.680 uV 15:55:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.761 uVs 15:55:46 Integrated Voltage Measurement... 15:55:55 Voltage Offset Correction: v_off_ini = 387.271 uV, v_off_fin = 388.235 uV 15:55:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.184 uVs 15:55:55 Integrated Voltage Measurement... 15:56:04 Voltage Offset Correction: v_off_ini = 376.222 uV, v_off_fin = 365.040 uV 15:56:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.312 uVs 15:56:04 Integrated Voltage Measurement... 15:56:13 Voltage Offset Correction: v_off_ini = 368.886 uV, v_off_fin = 363.053 uV 15:56:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.589 uVs 15:56:13 Integrated Voltage Measurement... 15:56:22 Voltage Offset Correction: v_off_ini = 390.314 uV, v_off_fin = 376.604 uV 15:56:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.678 uVs 15:56:22 Integrated Voltage Measurement... 15:56:31 Voltage Offset Correction: v_off_ini = 382.816 uV, v_off_fin = 407.014 uV 15:56:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.570 uVs 15:56:33 I2Y Average and RMS of Measurements VT = -207.849 +- 4.690 uVs I2Y = -19.122 +- 0.431 uTm^2 15:56:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:42 Integrated Voltage Measurement... 15:56:51 Voltage Offset Correction: v_off_ini = 395.555 uV, v_off_fin = 386.050 uV 15:56:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -99.426 uVs 15:56:51 Integrated Voltage Measurement... 15:57:00 Voltage Offset Correction: v_off_ini = 380.672 uV, v_off_fin = 392.332 uV 15:57:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.933 uVs 15:57:00 Integrated Voltage Measurement... 15:57:09 Voltage Offset Correction: v_off_ini = 380.117 uV, v_off_fin = 388.386 uV 15:57:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.877 uVs 15:57:09 Integrated Voltage Measurement... 15:57:18 Voltage Offset Correction: v_off_ini = 394.851 uV, v_off_fin = 391.595 uV 15:57:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.016 uVs 15:57:18 Integrated Voltage Measurement... 15:57:27 Voltage Offset Correction: v_off_ini = 377.639 uV, v_off_fin = 373.155 uV 15:57:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.937 uVs 15:57:27 Integrated Voltage Measurement... 15:57:36 Voltage Offset Correction: v_off_ini = 391.490 uV, v_off_fin = 385.404 uV 15:57:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.119 uVs 15:57:41 I1X Average and RMS of Measurements VT = -77.218 +- 6.857 uVs I1X = 15.445 +- 1.373 uTm 15:57:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:47 Integrated Voltage Measurement... 15:57:56 Voltage Offset Correction: v_off_ini = 362.994 uV, v_off_fin = 366.657 uV 15:57:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -173.105 uVs 15:57:56 Integrated Voltage Measurement... 15:58:05 Voltage Offset Correction: v_off_ini = 364.439 uV, v_off_fin = 393.440 uV 15:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.916 uVs 15:58:05 Integrated Voltage Measurement... 15:58:14 Voltage Offset Correction: v_off_ini = 389.622 uV, v_off_fin = 383.994 uV 15:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.609 uVs 15:58:14 Integrated Voltage Measurement... 15:58:23 Voltage Offset Correction: v_off_ini = 395.239 uV, v_off_fin = 387.219 uV 15:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.128 uVs 15:58:23 Integrated Voltage Measurement... 15:58:32 Voltage Offset Correction: v_off_ini = 398.288 uV, v_off_fin = 387.737 uV 15:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.437 uVs 15:58:32 Integrated Voltage Measurement... 15:58:41 Voltage Offset Correction: v_off_ini = 402.085 uV, v_off_fin = 398.101 uV 15:58:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.160 uVs 15:58:46 I1Y Average and RMS of Measurements VT = -172.559 +- 5.488 uVs I1Y = -34.512 +- 1.098 uTm 15:58:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:53 Integrated Voltage Measurement... 15:59:02 Voltage Offset Correction: v_off_ini = 379.386 uV, v_off_fin = 385.237 uV 15:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.787 uVs 15:59:02 Integrated Voltage Measurement... 15:59:11 Voltage Offset Correction: v_off_ini = 401.477 uV, v_off_fin = 401.472 uV 15:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.873 uVs 15:59:11 Integrated Voltage Measurement... 15:59:20 Voltage Offset Correction: v_off_ini = 372.516 uV, v_off_fin = 389.746 uV 15:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.368 uVs 15:59:20 Integrated Voltage Measurement... 15:59:29 Voltage Offset Correction: v_off_ini = 391.061 uV, v_off_fin = 399.405 uV 15:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.156 uVs 15:59:29 Integrated Voltage Measurement... 15:59:38 Voltage Offset Correction: v_off_ini = 402.074 uV, v_off_fin = 398.869 uV 15:59:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.709 uVs 15:59:39 Integrated Voltage Measurement... 15:59:47 Voltage Offset Correction: v_off_ini = 391.196 uV, v_off_fin = 389.229 uV 15:59:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.142 uVs 15:59:50 I2X Average and RMS of Measurements VT = -70.672 +- 9.296 uVs I2X = 6.502 +- 0.855 uTm^2 15:59:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:58 Integrated Voltage Measurement... 16:00:07 Voltage Offset Correction: v_off_ini = 399.975 uV, v_off_fin = 403.000 uV 16:00:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.411 uVs 16:00:07 Integrated Voltage Measurement... 16:00:16 Voltage Offset Correction: v_off_ini = 392.235 uV, v_off_fin = 399.364 uV 16:00:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.991 uVs 16:00:16 Integrated Voltage Measurement... 16:00:25 Voltage Offset Correction: v_off_ini = 394.607 uV, v_off_fin = 398.199 uV 16:00:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.244 uVs 16:00:25 Integrated Voltage Measurement... 16:00:34 Voltage Offset Correction: v_off_ini = 390.432 uV, v_off_fin = 387.756 uV 16:00:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.708 uVs 16:00:34 Integrated Voltage Measurement... 16:00:43 Voltage Offset Correction: v_off_ini = 389.667 uV, v_off_fin = 391.809 uV 16:00:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.728 uVs 16:00:43 Integrated Voltage Measurement... 16:00:52 Voltage Offset Correction: v_off_ini = 389.426 uV, v_off_fin = 393.766 uV 16:00:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.883 uVs 16:00:54 I2Y Average and RMS of Measurements VT = -209.327 +- 5.828 uVs I2Y = -19.258 +- 0.536 uTm^2 16:00:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:01:03 Integrated Voltage Measurement... 16:01:12 Voltage Offset Correction: v_off_ini = 366.253 uV, v_off_fin = 376.114 uV 16:01:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.604 uVs 16:01:12 Integrated Voltage Measurement... 16:01:21 Voltage Offset Correction: v_off_ini = 388.816 uV, v_off_fin = 380.264 uV 16:01:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.586 uVs 16:01:21 Integrated Voltage Measurement... 16:01:30 Voltage Offset Correction: v_off_ini = 409.230 uV, v_off_fin = 380.449 uV 16:01:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.999 uVs 16:01:30 Integrated Voltage Measurement... 16:01:39 Voltage Offset Correction: v_off_ini = 369.770 uV, v_off_fin = 380.811 uV 16:01:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.495 uVs 16:01:39 Integrated Voltage Measurement... 16:01:48 Voltage Offset Correction: v_off_ini = 375.780 uV, v_off_fin = 360.041 uV 16:01:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.492 uVs 16:01:48 Integrated Voltage Measurement... 16:01:57 Voltage Offset Correction: v_off_ini = 359.440 uV, v_off_fin = 388.925 uV 16:01:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.952 uVs 16:02:02 I1X Average and RMS of Measurements VT = -64.855 +- 18.312 uVs I1X = 12.971 +- 3.662 uTm 16:02:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:02:08 Integrated Voltage Measurement... 16:02:17 Voltage Offset Correction: v_off_ini = 347.354 uV, v_off_fin = 358.972 uV 16:02:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.829 uVs 16:02:17 Integrated Voltage Measurement... 16:02:26 Voltage Offset Correction: v_off_ini = 369.197 uV, v_off_fin = 372.896 uV 16:02:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.382 uVs 16:02:26 Integrated Voltage Measurement... 16:02:35 Voltage Offset Correction: v_off_ini = 381.748 uV, v_off_fin = 361.171 uV 16:02:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.702 uVs 16:02:35 Integrated Voltage Measurement... 16:02:44 Voltage Offset Correction: v_off_ini = 360.476 uV, v_off_fin = 387.823 uV 16:02:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.381 uVs 16:02:44 Integrated Voltage Measurement... 16:02:53 Voltage Offset Correction: v_off_ini = 387.891 uV, v_off_fin = 373.938 uV 16:02:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.682 uVs 16:02:53 Integrated Voltage Measurement... 16:03:02 Voltage Offset Correction: v_off_ini = 382.080 uV, v_off_fin = 378.899 uV 16:03:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.173 uVs 16:03:07 I1Y Average and RMS of Measurements VT = -164.191 +- 6.987 uVs I1Y = -32.838 +- 1.397 uTm 16:03:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:03:14 Integrated Voltage Measurement... 16:03:23 Voltage Offset Correction: v_off_ini = 358.555 uV, v_off_fin = 353.706 uV 16:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.956 uVs 16:03:23 Integrated Voltage Measurement... 16:03:32 Voltage Offset Correction: v_off_ini = 362.413 uV, v_off_fin = 381.142 uV 16:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.309 uVs 16:03:32 Integrated Voltage Measurement... 16:03:41 Voltage Offset Correction: v_off_ini = 358.722 uV, v_off_fin = 357.647 uV 16:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.623 uVs 16:03:41 Integrated Voltage Measurement... 16:03:50 Voltage Offset Correction: v_off_ini = 365.730 uV, v_off_fin = 366.188 uV 16:03:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.071 uVs 16:03:50 Integrated Voltage Measurement... 16:03:59 Voltage Offset Correction: v_off_ini = 347.981 uV, v_off_fin = 353.912 uV 16:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.323 uVs 16:04:00 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = 376.786 uV, v_off_fin = 388.027 uV 16:04:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.679 uVs 16:04:11 I2X Average and RMS of Measurements VT = -67.327 +- 10.117 uVs I2X = 6.194 +- 0.931 uTm^2 16:04:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:04:19 Integrated Voltage Measurement... 16:04:28 Voltage Offset Correction: v_off_ini = 368.304 uV, v_off_fin = 373.291 uV 16:04:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.152 uVs 16:04:28 Integrated Voltage Measurement... 16:04:37 Voltage Offset Correction: v_off_ini = 368.640 uV, v_off_fin = 363.075 uV 16:04:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.425 uVs 16:04:37 Integrated Voltage Measurement... 16:04:46 Voltage Offset Correction: v_off_ini = 384.369 uV, v_off_fin = 365.923 uV 16:04:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.878 uVs 16:04:46 Integrated Voltage Measurement... 16:04:55 Voltage Offset Correction: v_off_ini = 379.184 uV, v_off_fin = 376.576 uV 16:04:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.939 uVs 16:04:55 Integrated Voltage Measurement... 16:05:04 Voltage Offset Correction: v_off_ini = 386.878 uV, v_off_fin = 400.753 uV 16:05:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.173 uVs 16:05:04 Integrated Voltage Measurement... 16:05:13 Voltage Offset Correction: v_off_ini = 384.575 uV, v_off_fin = 387.486 uV 16:05:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.079 uVs 16:05:15 I2Y Average and RMS of Measurements VT = -209.107 +- 3.421 uVs I2Y = -19.238 +- 0.315 uTm^2 16:05:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:05:24 Integrated Voltage Measurement... 16:05:33 Voltage Offset Correction: v_off_ini = 398.444 uV, v_off_fin = 399.762 uV 16:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.715 uVs 16:05:33 Integrated Voltage Measurement... 16:05:42 Voltage Offset Correction: v_off_ini = 397.506 uV, v_off_fin = 391.611 uV 16:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.025 uVs 16:05:42 Integrated Voltage Measurement... 16:05:51 Voltage Offset Correction: v_off_ini = 393.625 uV, v_off_fin = 396.280 uV 16:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.316 uVs 16:05:51 Integrated Voltage Measurement... 16:06:00 Voltage Offset Correction: v_off_ini = 428.710 uV, v_off_fin = 419.833 uV 16:06:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.019 uVs 16:06:00 Integrated Voltage Measurement... 16:06:09 Voltage Offset Correction: v_off_ini = 421.723 uV, v_off_fin = 423.772 uV 16:06:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.951 uVs 16:06:09 Integrated Voltage Measurement... 16:06:18 Voltage Offset Correction: v_off_ini = 423.814 uV, v_off_fin = 429.140 uV 16:06:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.620 uVs 16:06:23 I1X Average and RMS of Measurements VT = -42.441 +- 13.449 uVs I1X = 8.488 +- 2.690 uTm 16:06:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:06:29 Integrated Voltage Measurement... 16:06:38 Voltage Offset Correction: v_off_ini = 430.098 uV, v_off_fin = 424.211 uV 16:06:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -174.748 uVs 16:06:38 Integrated Voltage Measurement... 16:06:47 Voltage Offset Correction: v_off_ini = 426.634 uV, v_off_fin = 445.346 uV 16:06:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.072 uVs 16:06:47 Integrated Voltage Measurement... 16:06:56 Voltage Offset Correction: v_off_ini = 422.948 uV, v_off_fin = 410.492 uV 16:06:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.439 uVs 16:06:56 Integrated Voltage Measurement... 16:07:05 Voltage Offset Correction: v_off_ini = 411.338 uV, v_off_fin = 422.353 uV 16:07:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.340 uVs 16:07:05 Integrated Voltage Measurement... 16:07:14 Voltage Offset Correction: v_off_ini = 417.981 uV, v_off_fin = 400.856 uV 16:07:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.977 uVs 16:07:14 Integrated Voltage Measurement... 16:07:23 Voltage Offset Correction: v_off_ini = 415.754 uV, v_off_fin = 430.206 uV 16:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.019 uVs 16:07:28 I1Y Average and RMS of Measurements VT = -172.766 +- 5.865 uVs I1Y = -34.554 +- 1.172 uTm 16:07:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:07:35 Integrated Voltage Measurement... 16:07:44 Voltage Offset Correction: v_off_ini = 408.872 uV, v_off_fin = 410.355 uV 16:07:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.476 uVs 16:07:44 Integrated Voltage Measurement... 16:07:53 Voltage Offset Correction: v_off_ini = 420.848 uV, v_off_fin = 429.760 uV 16:07:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.401 uVs 16:07:53 Integrated Voltage Measurement... 16:08:02 Voltage Offset Correction: v_off_ini = 413.877 uV, v_off_fin = 407.935 uV 16:08:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.006 uVs 16:08:02 Integrated Voltage Measurement... 16:08:11 Voltage Offset Correction: v_off_ini = 400.519 uV, v_off_fin = 427.925 uV 16:08:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 36.943 uVs 16:08:11 Integrated Voltage Measurement... 16:08:20 Voltage Offset Correction: v_off_ini = 421.328 uV, v_off_fin = 411.843 uV 16:08:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.459 uVs 16:08:20 Integrated Voltage Measurement... 16:08:29 Voltage Offset Correction: v_off_ini = 408.478 uV, v_off_fin = 418.603 uV 16:08:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.586 uVs 16:08:32 I2X Average and RMS of Measurements VT = -44.145 +- 4.238 uVs I2X = 4.062 +- 0.390 uTm^2 16:08:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:08:40 Integrated Voltage Measurement... 16:08:49 Voltage Offset Correction: v_off_ini = 419.688 uV, v_off_fin = 431.080 uV 16:08:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.167 uVs 16:08:49 Integrated Voltage Measurement... 16:08:58 Voltage Offset Correction: v_off_ini = 422.808 uV, v_off_fin = 414.303 uV 16:08:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.660 uVs 16:08:58 Integrated Voltage Measurement... 16:09:07 Voltage Offset Correction: v_off_ini = 408.170 uV, v_off_fin = 413.624 uV 16:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.592 uVs 16:09:07 Integrated Voltage Measurement... 16:09:16 Voltage Offset Correction: v_off_ini = 401.442 uV, v_off_fin = 386.813 uV 16:09:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.286 uVs 16:09:16 Integrated Voltage Measurement... 16:09:25 Voltage Offset Correction: v_off_ini = 394.052 uV, v_off_fin = 399.217 uV 16:09:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.431 uVs 16:09:25 Integrated Voltage Measurement... 16:09:34 Voltage Offset Correction: v_off_ini = 398.995 uV, v_off_fin = 388.021 uV 16:09:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.217 uVs 16:09:36 I2Y Average and RMS of Measurements VT = -208.226 +- 6.239 uVs I2Y = -19.157 +- 0.574 uTm^2 16:09:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:09:48 Integrated Voltage Measurement... 16:09:57 Voltage Offset Correction: v_off_ini = 376.059 uV, v_off_fin = 371.062 uV 16:09:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.913 uVs 16:09:57 Integrated Voltage Measurement... 16:10:06 Voltage Offset Correction: v_off_ini = 373.950 uV, v_off_fin = 380.157 uV 16:10:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.049 uVs 16:10:06 Integrated Voltage Measurement... 16:10:15 Voltage Offset Correction: v_off_ini = 381.222 uV, v_off_fin = 358.344 uV 16:10:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.430 uVs 16:10:15 Integrated Voltage Measurement... 16:10:24 Voltage Offset Correction: v_off_ini = 360.950 uV, v_off_fin = 358.368 uV 16:10:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.976 uVs 16:10:24 Integrated Voltage Measurement... 16:10:33 Voltage Offset Correction: v_off_ini = 356.993 uV, v_off_fin = 372.648 uV 16:10:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.435 uVs 16:10:33 Integrated Voltage Measurement... 16:10:42 Voltage Offset Correction: v_off_ini = 384.375 uV, v_off_fin = 372.767 uV 16:10:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.342 uVs 16:10:47 I1X Average and RMS of Measurements VT = -64.191 +- 10.397 uVs I1X = 12.838 +- 2.079 uTm 16:10:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:10:53 Integrated Voltage Measurement... 16:11:02 Voltage Offset Correction: v_off_ini = 374.904 uV, v_off_fin = 382.701 uV 16:11:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.950 uVs 16:11:02 Integrated Voltage Measurement... 16:11:11 Voltage Offset Correction: v_off_ini = 365.349 uV, v_off_fin = 381.187 uV 16:11:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.929 uVs 16:11:11 Integrated Voltage Measurement... 16:11:20 Voltage Offset Correction: v_off_ini = 378.889 uV, v_off_fin = 372.113 uV 16:11:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.428 uVs 16:11:20 Integrated Voltage Measurement... 16:11:29 Voltage Offset Correction: v_off_ini = 369.738 uV, v_off_fin = 402.818 uV 16:11:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.747 uVs 16:11:29 Integrated Voltage Measurement... 16:11:38 Voltage Offset Correction: v_off_ini = 381.689 uV, v_off_fin = 354.618 uV 16:11:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.673 uVs 16:11:38 Integrated Voltage Measurement... 16:11:47 Voltage Offset Correction: v_off_ini = 377.331 uV, v_off_fin = 373.149 uV 16:11:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.813 uVs 16:11:52 I1Y Average and RMS of Measurements VT = -193.257 +- 6.061 uVs I1Y = -38.651 +- 1.212 uTm 16:11:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:11:57 Integrated Voltage Measurement... 16:12:06 Voltage Offset Correction: v_off_ini = 352.168 uV, v_off_fin = 369.632 uV 16:12:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.515 uVs 16:12:06 Integrated Voltage Measurement... 16:12:15 Voltage Offset Correction: v_off_ini = 365.757 uV, v_off_fin = 369.704 uV 16:12:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.724 uVs 16:12:15 Integrated Voltage Measurement... 16:12:24 Voltage Offset Correction: v_off_ini = 359.769 uV, v_off_fin = 353.638 uV 16:12:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -45.716 uVs 16:12:24 Integrated Voltage Measurement... 16:12:33 Voltage Offset Correction: v_off_ini = 371.003 uV, v_off_fin = 379.130 uV 16:12:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.095 uVs 16:12:33 Integrated Voltage Measurement... 16:12:42 Voltage Offset Correction: v_off_ini = 375.334 uV, v_off_fin = 378.529 uV 16:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.844 uVs 16:12:42 Integrated Voltage Measurement... 16:12:51 Voltage Offset Correction: v_off_ini = 375.576 uV, v_off_fin = 383.441 uV 16:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.114 uVs 16:12:53 I2X Average and RMS of Measurements VT = -62.335 +- 4.950 uVs I2X = 5.735 +- 0.455 uTm^2 16:12:56 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:12:58 Integrated Voltage Measurement... 16:13:07 Voltage Offset Correction: v_off_ini = 382.378 uV, v_off_fin = 374.115 uV 16:13:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.979 uVs 16:13:07 Integrated Voltage Measurement... 16:13:16 Voltage Offset Correction: v_off_ini = 389.261 uV, v_off_fin = 397.078 uV 16:13:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 211.486 uVs 16:13:17 Integrated Voltage Measurement... 16:13:26 Voltage Offset Correction: v_off_ini = 385.941 uV, v_off_fin = 377.751 uV 16:13:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.277 uVs 16:13:26 Integrated Voltage Measurement... 16:13:35 Voltage Offset Correction: v_off_ini = 383.566 uV, v_off_fin = 383.691 uV 16:13:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.685 uVs 16:13:35 Integrated Voltage Measurement... 16:13:44 Voltage Offset Correction: v_off_ini = 385.533 uV, v_off_fin = 383.643 uV 16:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.254 uVs 16:13:44 Integrated Voltage Measurement... 16:13:53 Voltage Offset Correction: v_off_ini = 385.354 uV, v_off_fin = 371.609 uV 16:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.964 uVs 16:13:55 I2Y Average and RMS of Measurements VT = -214.274 +- 1.798 uVs I2Y = -19.714 +- 0.166 uTm^2 16:13:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:14:03 Integrated Voltage Measurement... 16:14:12 Voltage Offset Correction: v_off_ini = 366.648 uV, v_off_fin = 395.063 uV 16:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.034 uVs 16:14:12 Integrated Voltage Measurement... 16:14:21 Voltage Offset Correction: v_off_ini = 389.996 uV, v_off_fin = 396.601 uV 16:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.055 uVs 16:14:21 Integrated Voltage Measurement... 16:14:30 Voltage Offset Correction: v_off_ini = 380.670 uV, v_off_fin = 385.186 uV 16:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.927 uVs 16:14:31 Integrated Voltage Measurement... 16:14:39 Voltage Offset Correction: v_off_ini = 384.281 uV, v_off_fin = 395.929 uV 16:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.312 uVs 16:14:40 Integrated Voltage Measurement... 16:14:49 Voltage Offset Correction: v_off_ini = 391.508 uV, v_off_fin = 377.460 uV 16:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.141 uVs 16:14:49 Integrated Voltage Measurement... 16:14:58 Voltage Offset Correction: v_off_ini = 378.339 uV, v_off_fin = 390.556 uV 16:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.290 uVs 16:15:02 I1X Average and RMS of Measurements VT = -75.293 +- 11.931 uVs I1X = 15.059 +- 2.386 uTm 16:15:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:15:09 Integrated Voltage Measurement... 16:15:17 Voltage Offset Correction: v_off_ini = 374.913 uV, v_off_fin = 366.857 uV 16:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.642 uVs 16:15:18 Integrated Voltage Measurement... 16:15:26 Voltage Offset Correction: v_off_ini = 371.312 uV, v_off_fin = 383.066 uV 16:15:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.270 uVs 16:15:27 Integrated Voltage Measurement... 16:15:35 Voltage Offset Correction: v_off_ini = 368.930 uV, v_off_fin = 371.792 uV 16:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.335 uVs 16:15:36 Integrated Voltage Measurement... 16:15:44 Voltage Offset Correction: v_off_ini = 372.187 uV, v_off_fin = 376.264 uV 16:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.135 uVs 16:15:45 Integrated Voltage Measurement... 16:15:54 Voltage Offset Correction: v_off_ini = 405.190 uV, v_off_fin = 363.024 uV 16:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.294 uVs 16:15:54 Integrated Voltage Measurement... 16:16:03 Voltage Offset Correction: v_off_ini = 384.299 uV, v_off_fin = 384.704 uV 16:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.112 uVs 16:16:07 I1Y Average and RMS of Measurements VT = -191.965 +- 6.910 uVs I1Y = -38.394 +- 1.383 uTm 16:16:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:16:12 Integrated Voltage Measurement... 16:16:21 Voltage Offset Correction: v_off_ini = 358.386 uV, v_off_fin = 348.181 uV 16:16:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.616 uVs 16:16:21 Integrated Voltage Measurement... 16:16:30 Voltage Offset Correction: v_off_ini = 349.095 uV, v_off_fin = 385.395 uV 16:16:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.020 uVs 16:16:30 Integrated Voltage Measurement... 16:16:39 Voltage Offset Correction: v_off_ini = 368.883 uV, v_off_fin = 361.816 uV 16:16:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.598 uVs 16:16:39 Integrated Voltage Measurement... 16:16:48 Voltage Offset Correction: v_off_ini = 356.291 uV, v_off_fin = 366.629 uV 16:16:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.090 uVs 16:16:48 Integrated Voltage Measurement... 16:16:57 Voltage Offset Correction: v_off_ini = 378.201 uV, v_off_fin = 354.746 uV 16:16:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.274 uVs 16:16:57 Integrated Voltage Measurement... 16:17:06 Voltage Offset Correction: v_off_ini = 364.888 uV, v_off_fin = 372.421 uV 16:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.507 uVs 16:17:09 I2X Average and RMS of Measurements VT = -66.351 +- 17.089 uVs I2X = 6.104 +- 1.572 uTm^2 16:17:11 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:17:14 Integrated Voltage Measurement... 16:17:23 Voltage Offset Correction: v_off_ini = 347.419 uV, v_off_fin = 372.171 uV 16:17:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.260 uVs 16:17:23 Integrated Voltage Measurement... 16:17:32 Voltage Offset Correction: v_off_ini = 395.607 uV, v_off_fin = 384.682 uV 16:17:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.063 uVs 16:17:32 Integrated Voltage Measurement... 16:17:41 Voltage Offset Correction: v_off_ini = 374.980 uV, v_off_fin = 360.019 uV 16:17:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.532 uVs 16:17:41 Integrated Voltage Measurement... 16:17:50 Voltage Offset Correction: v_off_ini = 370.868 uV, v_off_fin = 345.993 uV 16:17:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.277 uVs 16:17:50 Integrated Voltage Measurement... 16:17:59 Voltage Offset Correction: v_off_ini = 380.016 uV, v_off_fin = 369.747 uV 16:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.162 uVs 16:17:59 Integrated Voltage Measurement... 16:18:08 Voltage Offset Correction: v_off_ini = 364.736 uV, v_off_fin = 362.422 uV 16:18:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.343 uVs 16:18:10 I2Y Average and RMS of Measurements VT = -221.940 +- 8.113 uVs I2Y = -20.418 +- 0.746 uTm^2 16:18:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:19 Integrated Voltage Measurement... 16:18:28 Voltage Offset Correction: v_off_ini = 363.252 uV, v_off_fin = 357.314 uV 16:18:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.278 uVs 16:18:28 Integrated Voltage Measurement... 16:18:37 Voltage Offset Correction: v_off_ini = 354.128 uV, v_off_fin = 369.292 uV 16:18:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.661 uVs 16:18:37 Integrated Voltage Measurement... 16:18:46 Voltage Offset Correction: v_off_ini = 363.277 uV, v_off_fin = 350.455 uV 16:18:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.564 uVs 16:18:46 Integrated Voltage Measurement... 16:18:55 Voltage Offset Correction: v_off_ini = 367.965 uV, v_off_fin = 378.041 uV 16:18:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.250 uVs 16:18:55 Integrated Voltage Measurement... 16:19:04 Voltage Offset Correction: v_off_ini = 371.399 uV, v_off_fin = 348.885 uV 16:19:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.898 uVs 16:19:04 Integrated Voltage Measurement... 16:19:13 Voltage Offset Correction: v_off_ini = 355.825 uV, v_off_fin = 348.537 uV 16:19:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.644 uVs 16:19:17 I1X Average and RMS of Measurements VT = -87.216 +- 0.899 uVs I1X = 17.443 +- 0.180 uTm 16:19:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:24 Integrated Voltage Measurement... 16:19:33 Voltage Offset Correction: v_off_ini = 372.164 uV, v_off_fin = 353.165 uV 16:19:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.425 uVs 16:19:33 Integrated Voltage Measurement... 16:19:42 Voltage Offset Correction: v_off_ini = 375.311 uV, v_off_fin = 369.256 uV 16:19:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.363 uVs 16:19:42 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = 371.858 uV, v_off_fin = 357.791 uV 16:19:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.962 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = 383.185 uV, v_off_fin = 377.790 uV 16:20:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.014 uVs 16:20:00 Integrated Voltage Measurement... 16:20:09 Voltage Offset Correction: v_off_ini = 386.733 uV, v_off_fin = 373.139 uV 16:20:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.164 uVs 16:20:09 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = 378.120 uV, v_off_fin = 385.922 uV 16:20:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.536 uVs 16:20:22 I1Y Average and RMS of Measurements VT = -175.077 +- 3.755 uVs I1Y = -35.016 +- 0.752 uTm 16:20:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:27 Integrated Voltage Measurement... 16:20:36 Voltage Offset Correction: v_off_ini = 389.249 uV, v_off_fin = 378.014 uV 16:20:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.563 uVs 16:20:36 Integrated Voltage Measurement... 16:20:45 Voltage Offset Correction: v_off_ini = 379.236 uV, v_off_fin = 384.304 uV 16:20:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.947 uVs 16:20:45 Integrated Voltage Measurement... 16:20:54 Voltage Offset Correction: v_off_ini = 373.541 uV, v_off_fin = 387.422 uV 16:20:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.371 uVs 16:20:54 Integrated Voltage Measurement... 16:21:03 Voltage Offset Correction: v_off_ini = 392.247 uV, v_off_fin = 397.801 uV 16:21:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.063 uVs 16:21:03 Integrated Voltage Measurement... 16:21:12 Voltage Offset Correction: v_off_ini = 372.735 uV, v_off_fin = 376.176 uV 16:21:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.540 uVs 16:21:12 Integrated Voltage Measurement... 16:21:21 Voltage Offset Correction: v_off_ini = 395.426 uV, v_off_fin = 399.476 uV 16:21:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.583 uVs 16:21:24 I2X Average and RMS of Measurements VT = -68.845 +- 17.270 uVs I2X = 6.334 +- 1.589 uTm^2 16:21:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:29 Integrated Voltage Measurement... 16:21:38 Voltage Offset Correction: v_off_ini = 390.722 uV, v_off_fin = 388.973 uV 16:21:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.247 uVs 16:21:38 Integrated Voltage Measurement... 16:21:47 Voltage Offset Correction: v_off_ini = 402.924 uV, v_off_fin = 408.388 uV 16:21:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.216 uVs 16:21:47 Integrated Voltage Measurement... 16:21:56 Voltage Offset Correction: v_off_ini = 403.828 uV, v_off_fin = 395.211 uV 16:21:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.816 uVs 16:21:56 Integrated Voltage Measurement... 16:22:05 Voltage Offset Correction: v_off_ini = 388.871 uV, v_off_fin = 396.939 uV 16:22:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 198.007 uVs 16:22:05 Integrated Voltage Measurement... 16:22:14 Voltage Offset Correction: v_off_ini = 409.857 uV, v_off_fin = 380.506 uV 16:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.930 uVs 16:22:14 Integrated Voltage Measurement... 16:22:23 Voltage Offset Correction: v_off_ini = 389.651 uV, v_off_fin = 409.705 uV 16:22:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 189.442 uVs 16:22:26 I2Y Average and RMS of Measurements VT = -209.443 +- 5.510 uVs I2Y = -19.269 +- 0.507 uTm^2 16:22:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:22:34 Integrated Voltage Measurement... 16:22:43 Voltage Offset Correction: v_off_ini = 402.165 uV, v_off_fin = 401.573 uV 16:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.205 uVs 16:22:43 Integrated Voltage Measurement... 16:22:52 Voltage Offset Correction: v_off_ini = 390.730 uV, v_off_fin = 404.481 uV 16:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.382 uVs 16:22:52 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = 411.621 uV, v_off_fin = 416.153 uV 16:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.173 uVs 16:23:01 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = 389.580 uV, v_off_fin = 397.220 uV 16:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.887 uVs 16:23:10 Integrated Voltage Measurement... 16:23:19 Voltage Offset Correction: v_off_ini = 407.110 uV, v_off_fin = 385.673 uV 16:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.322 uVs 16:23:19 Integrated Voltage Measurement... 16:23:28 Voltage Offset Correction: v_off_ini = 375.401 uV, v_off_fin = 383.135 uV 16:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.118 uVs 16:23:32 I1X Average and RMS of Measurements VT = -71.014 +- 4.944 uVs I1X = 14.203 +- 0.989 uTm 16:23:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:23:39 Integrated Voltage Measurement... 16:23:48 Voltage Offset Correction: v_off_ini = 386.104 uV, v_off_fin = 394.706 uV 16:23:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.413 uVs 16:23:48 Integrated Voltage Measurement... 16:23:57 Voltage Offset Correction: v_off_ini = 397.988 uV, v_off_fin = 418.681 uV 16:23:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.078 uVs 16:23:57 Integrated Voltage Measurement... 16:24:06 Voltage Offset Correction: v_off_ini = 390.431 uV, v_off_fin = 381.301 uV 16:24:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -158.902 uVs 16:24:06 Integrated Voltage Measurement... 16:24:15 Voltage Offset Correction: v_off_ini = 397.625 uV, v_off_fin = 420.285 uV 16:24:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 174.570 uVs 16:24:15 Integrated Voltage Measurement... 16:24:24 Voltage Offset Correction: v_off_ini = 403.240 uV, v_off_fin = 393.590 uV 16:24:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.130 uVs 16:24:24 Integrated Voltage Measurement... 16:24:33 Voltage Offset Correction: v_off_ini = 386.566 uV, v_off_fin = 413.441 uV 16:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.468 uVs 16:24:37 I1Y Average and RMS of Measurements VT = -166.927 +- 1.051 uVs I1Y = -33.384 +- 0.210 uTm 16:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:24:42 Integrated Voltage Measurement... 16:24:51 Voltage Offset Correction: v_off_ini = 393.949 uV, v_off_fin = 385.077 uV 16:24:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.697 uVs 16:24:51 Integrated Voltage Measurement... 16:25:00 Voltage Offset Correction: v_off_ini = 405.490 uV, v_off_fin = 421.032 uV 16:25:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.689 uVs 16:25:00 Integrated Voltage Measurement... 16:25:09 Voltage Offset Correction: v_off_ini = 401.255 uV, v_off_fin = 390.215 uV 16:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.150 uVs 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = 412.801 uV, v_off_fin = 399.072 uV 16:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.149 uVs 16:25:19 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = 399.974 uV, v_off_fin = 390.191 uV 16:25:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.944 uVs 16:25:28 Integrated Voltage Measurement... 16:25:37 Voltage Offset Correction: v_off_ini = 401.213 uV, v_off_fin = 401.616 uV 16:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.259 uVs 16:25:39 I2X Average and RMS of Measurements VT = -64.315 +- 0.878 uVs I2X = 5.917 +- 0.081 uTm^2 16:25:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:25:44 Integrated Voltage Measurement... 16:25:53 Voltage Offset Correction: v_off_ini = 406.936 uV, v_off_fin = 398.863 uV 16:25:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.238 uVs 16:25:53 Integrated Voltage Measurement... 16:26:02 Voltage Offset Correction: v_off_ini = 404.206 uV, v_off_fin = 388.463 uV 16:26:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.453 uVs 16:26:02 Integrated Voltage Measurement... 16:26:11 Voltage Offset Correction: v_off_ini = 396.533 uV, v_off_fin = 393.581 uV 16:26:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.608 uVs 16:26:11 Integrated Voltage Measurement... 16:26:20 Voltage Offset Correction: v_off_ini = 394.192 uV, v_off_fin = 400.207 uV 16:26:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 206.933 uVs 16:26:20 Integrated Voltage Measurement... 16:26:29 Voltage Offset Correction: v_off_ini = 407.805 uV, v_off_fin = 397.147 uV 16:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.442 uVs 16:26:29 Integrated Voltage Measurement... 16:26:38 Voltage Offset Correction: v_off_ini = 381.102 uV, v_off_fin = 407.785 uV 16:26:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.133 uVs 16:26:41 I2Y Average and RMS of Measurements VT = -198.968 +- 5.074 uVs I2Y = -18.306 +- 0.467 uTm^2 16:26:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:26:49 Integrated Voltage Measurement... 16:26:58 Voltage Offset Correction: v_off_ini = 404.088 uV, v_off_fin = 402.291 uV 16:26:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.918 uVs 16:26:58 Integrated Voltage Measurement... 16:27:07 Voltage Offset Correction: v_off_ini = 408.873 uV, v_off_fin = 399.760 uV 16:27:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.466 uVs 16:27:07 Integrated Voltage Measurement... 16:27:16 Voltage Offset Correction: v_off_ini = 403.177 uV, v_off_fin = 398.262 uV 16:27:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.186 uVs 16:27:16 Integrated Voltage Measurement... 16:27:25 Voltage Offset Correction: v_off_ini = 409.478 uV, v_off_fin = 405.290 uV 16:27:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.250 uVs 16:27:25 Integrated Voltage Measurement... 16:27:34 Voltage Offset Correction: v_off_ini = 410.111 uV, v_off_fin = 402.180 uV 16:27:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.051 uVs 16:27:34 Integrated Voltage Measurement... 16:27:43 Voltage Offset Correction: v_off_ini = 379.881 uV, v_off_fin = 412.494 uV 16:27:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.055 uVs 16:27:47 I1X Average and RMS of Measurements VT = -79.321 +- 7.870 uVs I1X = 15.864 +- 1.574 uTm 16:27:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:27:54 Integrated Voltage Measurement... 16:28:03 Voltage Offset Correction: v_off_ini = 379.000 uV, v_off_fin = 388.655 uV 16:28:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.219 uVs 16:28:03 Integrated Voltage Measurement... 16:28:12 Voltage Offset Correction: v_off_ini = 402.727 uV, v_off_fin = 430.261 uV 16:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.216 uVs 16:28:12 Integrated Voltage Measurement... 16:28:21 Voltage Offset Correction: v_off_ini = 424.672 uV, v_off_fin = 423.061 uV 16:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.618 uVs 16:28:21 Integrated Voltage Measurement... 16:28:30 Voltage Offset Correction: v_off_ini = 439.782 uV, v_off_fin = 426.701 uV 16:28:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 132.432 uVs 16:28:30 Integrated Voltage Measurement... 16:28:39 Voltage Offset Correction: v_off_ini = 422.017 uV, v_off_fin = 403.170 uV 16:28:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.847 uVs 16:28:39 Integrated Voltage Measurement... 16:28:48 Voltage Offset Correction: v_off_ini = 408.002 uV, v_off_fin = 425.403 uV 16:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.524 uVs 16:28:52 I1Y Average and RMS of Measurements VT = -147.476 +- 7.584 uVs I1Y = -29.496 +- 1.517 uTm 16:28:55 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:28:58 Integrated Voltage Measurement... 16:29:07 Voltage Offset Correction: v_off_ini = 410.558 uV, v_off_fin = 392.473 uV 16:29:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.580 uVs 16:29:07 Integrated Voltage Measurement... 16:29:16 Voltage Offset Correction: v_off_ini = 427.854 uV, v_off_fin = 445.869 uV 16:29:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.951 uVs 16:29:16 Integrated Voltage Measurement... 16:29:25 Voltage Offset Correction: v_off_ini = 409.879 uV, v_off_fin = 407.955 uV 16:29:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.673 uVs 16:29:25 Integrated Voltage Measurement... 16:29:34 Voltage Offset Correction: v_off_ini = 388.832 uV, v_off_fin = 409.483 uV 16:29:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.831 uVs 16:29:34 Integrated Voltage Measurement... 16:29:43 Voltage Offset Correction: v_off_ini = 397.162 uV, v_off_fin = 391.037 uV 16:29:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.538 uVs 16:29:43 Integrated Voltage Measurement... 16:29:52 Voltage Offset Correction: v_off_ini = 407.449 uV, v_off_fin = 419.461 uV 16:29:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.694 uVs 16:29:54 I2X Average and RMS of Measurements VT = -57.045 +- 7.110 uVs I2X = 5.248 +- 0.654 uTm^2 16:29:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = 410.887 uV, v_off_fin = 417.489 uV 16:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.852 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = 420.748 uV, v_off_fin = 401.001 uV 16:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.473 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = 409.460 uV, v_off_fin = 413.804 uV 16:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.640 uVs 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 398.050 uV, v_off_fin = 391.269 uV 16:30:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.304 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 398.799 uV, v_off_fin = 395.833 uV 16:30:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.345 uVs 16:30:45 Integrated Voltage Measurement... 16:30:54 Voltage Offset Correction: v_off_ini = 398.130 uV, v_off_fin = 409.134 uV 16:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.113 uVs 16:30:56 I2Y Average and RMS of Measurements VT = -202.288 +- 8.942 uVs I2Y = -18.610 +- 0.823 uTm^2 16:31:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:31:17 Integrated Voltage Measurement... 16:31:26 Voltage Offset Correction: v_off_ini = 405.954 uV, v_off_fin = 403.247 uV 16:31:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -135.736 uVs 16:31:26 Integrated Voltage Measurement... 16:31:35 Voltage Offset Correction: v_off_ini = 411.415 uV, v_off_fin = 413.140 uV 16:31:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.684 uVs 16:31:35 Integrated Voltage Measurement... 16:31:44 Voltage Offset Correction: v_off_ini = 406.931 uV, v_off_fin = 401.576 uV 16:31:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.433 uVs 16:31:44 Integrated Voltage Measurement... 16:31:53 Voltage Offset Correction: v_off_ini = 401.693 uV, v_off_fin = 417.686 uV 16:31:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.175 uVs 16:31:53 Integrated Voltage Measurement... 16:32:02 Voltage Offset Correction: v_off_ini = 399.914 uV, v_off_fin = 403.144 uV 16:32:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -142.081 uVs 16:32:02 Integrated Voltage Measurement... 16:32:11 Voltage Offset Correction: v_off_ini = 407.742 uV, v_off_fin = 413.238 uV 16:32:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.033 uVs 16:32:16 I1X Average and RMS of Measurements VT = -122.524 +- 13.960 uVs I1X = 24.507 +- 2.792 uTm 16:32:18 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:32:22 Integrated Voltage Measurement... 16:32:31 Voltage Offset Correction: v_off_ini = 404.346 uV, v_off_fin = 400.967 uV 16:32:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -184.880 uVs 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 408.949 uV, v_off_fin = 425.352 uV 16:32:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.971 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 424.749 uV, v_off_fin = 394.135 uV 16:32:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.456 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 405.202 uV, v_off_fin = 416.669 uV 16:32:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.863 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 404.451 uV, v_off_fin = 406.607 uV 16:33:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.081 uVs 16:33:07 Integrated Voltage Measurement... 16:33:16 Voltage Offset Correction: v_off_ini = 402.124 uV, v_off_fin = 408.255 uV 16:33:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.523 uVs 16:33:21 I1Y Average and RMS of Measurements VT = -191.796 +- 3.429 uVs I1Y = -38.360 +- 0.685 uTm 16:33:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:33:28 Integrated Voltage Measurement... 16:33:37 Voltage Offset Correction: v_off_ini = 407.479 uV, v_off_fin = 406.168 uV 16:33:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.328 uVs 16:33:37 Integrated Voltage Measurement... 16:33:46 Voltage Offset Correction: v_off_ini = 407.374 uV, v_off_fin = 402.904 uV 16:33:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.446 uVs 16:33:46 Integrated Voltage Measurement... 16:33:55 Voltage Offset Correction: v_off_ini = 424.980 uV, v_off_fin = 400.466 uV 16:33:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.559 uVs 16:33:55 Integrated Voltage Measurement... 16:34:04 Voltage Offset Correction: v_off_ini = 412.804 uV, v_off_fin = 421.166 uV 16:34:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.476 uVs 16:34:04 Integrated Voltage Measurement... 16:34:13 Voltage Offset Correction: v_off_ini = 396.876 uV, v_off_fin = 395.334 uV 16:34:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.919 uVs 16:34:13 Integrated Voltage Measurement... 16:34:22 Voltage Offset Correction: v_off_ini = 419.230 uV, v_off_fin = 405.089 uV 16:34:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.994 uVs 16:34:25 I2X Average and RMS of Measurements VT = -110.954 +- 8.403 uVs I2X = 10.208 +- 0.773 uTm^2 16:34:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:34:33 Integrated Voltage Measurement... 16:34:42 Voltage Offset Correction: v_off_ini = 398.653 uV, v_off_fin = 375.161 uV 16:34:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.596 uVs 16:34:42 Integrated Voltage Measurement... 16:34:51 Voltage Offset Correction: v_off_ini = 403.356 uV, v_off_fin = 398.794 uV 16:34:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.178 uVs 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 386.285 uV, v_off_fin = 397.506 uV 16:35:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -235.047 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 386.934 uV, v_off_fin = 402.088 uV 16:35:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.325 uVs 16:35:09 Integrated Voltage Measurement... 16:35:18 Voltage Offset Correction: v_off_ini = 386.724 uV, v_off_fin = 382.745 uV 16:35:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.918 uVs 16:35:18 Integrated Voltage Measurement... 16:35:27 Voltage Offset Correction: v_off_ini = 395.489 uV, v_off_fin = 392.165 uV 16:35:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 215.471 uVs 16:35:29 I2Y Average and RMS of Measurements VT = -229.589 +- 5.529 uVs I2Y = -21.123 +- 0.508 uTm^2 16:35:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:35:38 Integrated Voltage Measurement... 16:35:47 Voltage Offset Correction: v_off_ini = 401.516 uV, v_off_fin = 401.628 uV 16:35:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.895 uVs 16:35:47 Integrated Voltage Measurement... 16:35:56 Voltage Offset Correction: v_off_ini = 403.191 uV, v_off_fin = 389.829 uV 16:35:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.198 uVs 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 394.530 uV, v_off_fin = 396.906 uV 16:36:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.859 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 396.257 uV, v_off_fin = 394.858 uV 16:36:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.538 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 392.548 uV, v_off_fin = 388.330 uV 16:36:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.031 uVs 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 395.594 uV, v_off_fin = 387.063 uV 16:36:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.792 uVs 16:36:36 I1X Average and RMS of Measurements VT = -113.052 +- 3.468 uVs I1X = 22.610 +- 0.694 uTm 16:36:39 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:36:43 Integrated Voltage Measurement... 16:36:52 Voltage Offset Correction: v_off_ini = 409.994 uV, v_off_fin = 394.340 uV 16:36:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -190.931 uVs 16:36:52 Integrated Voltage Measurement... 16:37:01 Voltage Offset Correction: v_off_ini = 414.803 uV, v_off_fin = 418.779 uV 16:37:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.886 uVs 16:37:01 Integrated Voltage Measurement... 16:37:10 Voltage Offset Correction: v_off_ini = 398.555 uV, v_off_fin = 387.998 uV 16:37:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.471 uVs 16:37:10 Integrated Voltage Measurement... 16:37:19 Voltage Offset Correction: v_off_ini = 402.107 uV, v_off_fin = 396.558 uV 16:37:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.471 uVs 16:37:19 Integrated Voltage Measurement... 16:37:28 Voltage Offset Correction: v_off_ini = 407.115 uV, v_off_fin = 400.930 uV 16:37:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.368 uVs 16:37:28 Integrated Voltage Measurement... 16:37:37 Voltage Offset Correction: v_off_ini = 400.474 uV, v_off_fin = 416.376 uV 16:37:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.246 uVs 16:37:41 I1Y Average and RMS of Measurements VT = -191.729 +- 4.138 uVs I1Y = -38.347 +- 0.826 uTm 16:37:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:37:49 Integrated Voltage Measurement... 16:37:58 Voltage Offset Correction: v_off_ini = 399.670 uV, v_off_fin = 379.380 uV 16:37:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.123 uVs 16:37:58 Integrated Voltage Measurement... 16:38:07 Voltage Offset Correction: v_off_ini = 385.092 uV, v_off_fin = 407.991 uV 16:38:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.119 uVs 16:38:07 Integrated Voltage Measurement... 16:38:16 Voltage Offset Correction: v_off_ini = 394.129 uV, v_off_fin = 400.377 uV 16:38:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.731 uVs 16:38:16 Integrated Voltage Measurement... 16:38:25 Voltage Offset Correction: v_off_ini = 389.892 uV, v_off_fin = 398.405 uV 16:38:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.454 uVs 16:38:25 Integrated Voltage Measurement... 16:38:34 Voltage Offset Correction: v_off_ini = 381.715 uV, v_off_fin = 397.250 uV 16:38:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.809 uVs 16:38:34 Integrated Voltage Measurement... 16:38:43 Voltage Offset Correction: v_off_ini = 417.958 uV, v_off_fin = 419.406 uV 16:38:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.210 uVs 16:38:45 I2X Average and RMS of Measurements VT = -117.074 +- 12.644 uVs I2X = 10.771 +- 1.163 uTm^2 16:38:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:38:53 Integrated Voltage Measurement... 16:39:02 Voltage Offset Correction: v_off_ini = 399.212 uV, v_off_fin = 399.977 uV 16:39:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.364 uVs 16:39:02 Integrated Voltage Measurement... 16:39:11 Voltage Offset Correction: v_off_ini = 399.326 uV, v_off_fin = 411.890 uV 16:39:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.991 uVs 16:39:11 Integrated Voltage Measurement... 16:39:20 Voltage Offset Correction: v_off_ini = 382.732 uV, v_off_fin = 406.639 uV 16:39:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.260 uVs 16:39:20 Integrated Voltage Measurement... 16:39:29 Voltage Offset Correction: v_off_ini = 400.233 uV, v_off_fin = 411.089 uV 16:39:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.307 uVs 16:39:29 Integrated Voltage Measurement... 16:39:38 Voltage Offset Correction: v_off_ini = 383.225 uV, v_off_fin = 390.623 uV 16:39:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.883 uVs 16:39:38 Integrated Voltage Measurement... 16:39:47 Voltage Offset Correction: v_off_ini = 394.298 uV, v_off_fin = 404.027 uV 16:39:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.413 uVs 16:39:50 I2Y Average and RMS of Measurements VT = -228.537 +- 6.990 uVs I2Y = -21.025 +- 0.643 uTm^2 16:39:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:59 Integrated Voltage Measurement... 16:40:08 Voltage Offset Correction: v_off_ini = 419.171 uV, v_off_fin = 414.585 uV 16:40:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.354 uVs 16:40:08 Integrated Voltage Measurement... 16:40:17 Voltage Offset Correction: v_off_ini = 403.444 uV, v_off_fin = 429.750 uV 16:40:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.902 uVs 16:40:17 Integrated Voltage Measurement... 16:40:26 Voltage Offset Correction: v_off_ini = 405.082 uV, v_off_fin = 399.987 uV 16:40:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.110 uVs 16:40:26 Integrated Voltage Measurement... 16:40:35 Voltage Offset Correction: v_off_ini = 421.920 uV, v_off_fin = 418.335 uV 16:40:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.219 uVs 16:40:35 Integrated Voltage Measurement... 16:40:44 Voltage Offset Correction: v_off_ini = 412.180 uV, v_off_fin = 405.703 uV 16:40:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.635 uVs 16:40:44 Integrated Voltage Measurement... 16:40:53 Voltage Offset Correction: v_off_ini = 398.300 uV, v_off_fin = 390.426 uV 16:40:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.410 uVs 16:40:57 I1X Average and RMS of Measurements VT = -95.271 +- 2.419 uVs I1X = 19.055 +- 0.484 uTm 16:40:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:04 Integrated Voltage Measurement... 16:41:13 Voltage Offset Correction: v_off_ini = 403.841 uV, v_off_fin = 395.701 uV 16:41:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -187.755 uVs 16:41:13 Integrated Voltage Measurement... 16:41:21 Voltage Offset Correction: v_off_ini = 396.636 uV, v_off_fin = 401.661 uV 16:41:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.625 uVs 16:41:22 Integrated Voltage Measurement... 16:41:30 Voltage Offset Correction: v_off_ini = 387.358 uV, v_off_fin = 393.110 uV 16:41:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.015 uVs 16:41:31 Integrated Voltage Measurement... 16:41:39 Voltage Offset Correction: v_off_ini = 399.856 uV, v_off_fin = 404.300 uV 16:41:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.970 uVs 16:41:40 Integrated Voltage Measurement... 16:41:48 Voltage Offset Correction: v_off_ini = 387.502 uV, v_off_fin = 396.180 uV 16:41:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.169 uVs 16:41:49 Integrated Voltage Measurement... 16:41:57 Voltage Offset Correction: v_off_ini = 407.040 uV, v_off_fin = 414.575 uV 16:41:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.924 uVs 16:42:02 I1Y Average and RMS of Measurements VT = -192.243 +- 2.022 uVs I1Y = -38.450 +- 0.403 uTm 16:42:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:09 Integrated Voltage Measurement... 16:42:18 Voltage Offset Correction: v_off_ini = 396.911 uV, v_off_fin = 403.933 uV 16:42:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.615 uVs 16:42:18 Integrated Voltage Measurement... 16:42:27 Voltage Offset Correction: v_off_ini = 406.741 uV, v_off_fin = 401.898 uV 16:42:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.368 uVs 16:42:27 Integrated Voltage Measurement... 16:42:36 Voltage Offset Correction: v_off_ini = 411.082 uV, v_off_fin = 410.162 uV 16:42:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.914 uVs 16:42:36 Integrated Voltage Measurement... 16:42:45 Voltage Offset Correction: v_off_ini = 413.668 uV, v_off_fin = 410.007 uV 16:42:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 90.212 uVs 16:42:45 Integrated Voltage Measurement... 16:42:54 Voltage Offset Correction: v_off_ini = 393.898 uV, v_off_fin = 396.144 uV 16:42:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.649 uVs 16:42:54 Integrated Voltage Measurement... 16:43:03 Voltage Offset Correction: v_off_ini = 395.790 uV, v_off_fin = 416.298 uV 16:43:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.237 uVs 16:43:06 I2X Average and RMS of Measurements VT = -92.499 +- 3.513 uVs I2X = 8.510 +- 0.323 uTm^2 16:43:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:14 Integrated Voltage Measurement... 16:43:23 Voltage Offset Correction: v_off_ini = 404.684 uV, v_off_fin = 410.586 uV 16:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.097 uVs 16:43:23 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = 411.287 uV, v_off_fin = 417.439 uV 16:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.937 uVs 16:43:32 Integrated Voltage Measurement... 16:43:41 Voltage Offset Correction: v_off_ini = 421.753 uV, v_off_fin = 411.613 uV 16:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.102 uVs 16:43:41 Integrated Voltage Measurement... 16:43:50 Voltage Offset Correction: v_off_ini = 424.242 uV, v_off_fin = 426.869 uV 16:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.365 uVs 16:43:50 Integrated Voltage Measurement... 16:43:59 Voltage Offset Correction: v_off_ini = 415.022 uV, v_off_fin = 414.798 uV 16:43:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.470 uVs 16:43:59 Integrated Voltage Measurement... 16:44:08 Voltage Offset Correction: v_off_ini = 402.757 uV, v_off_fin = 397.596 uV 16:44:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.342 uVs 16:44:10 I2Y Average and RMS of Measurements VT = -223.719 +- 5.293 uVs I2Y = -20.582 +- 0.487 uTm^2 16:44:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:44:19 Integrated Voltage Measurement... 16:44:28 Voltage Offset Correction: v_off_ini = 411.796 uV, v_off_fin = 409.671 uV 16:44:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.690 uVs 16:44:28 Integrated Voltage Measurement... 16:44:37 Voltage Offset Correction: v_off_ini = 413.558 uV, v_off_fin = 399.630 uV 16:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.204 uVs 16:44:37 Integrated Voltage Measurement... 16:44:46 Voltage Offset Correction: v_off_ini = 437.123 uV, v_off_fin = 413.801 uV 16:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.573 uVs 16:44:46 Integrated Voltage Measurement... 16:44:55 Voltage Offset Correction: v_off_ini = 422.477 uV, v_off_fin = 417.767 uV 16:44:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.576 uVs 16:44:55 Integrated Voltage Measurement... 16:45:04 Voltage Offset Correction: v_off_ini = 413.330 uV, v_off_fin = 415.317 uV 16:45:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.719 uVs 16:45:04 Integrated Voltage Measurement... 16:45:13 Voltage Offset Correction: v_off_ini = 443.135 uV, v_off_fin = 440.145 uV 16:45:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.512 uVs 16:45:17 I1X Average and RMS of Measurements VT = -88.212 +- 8.421 uVs I1X = 17.643 +- 1.684 uTm 16:45:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:45:24 Integrated Voltage Measurement... 16:45:33 Voltage Offset Correction: v_off_ini = 433.089 uV, v_off_fin = 434.159 uV 16:45:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.011 uVs 16:45:33 Integrated Voltage Measurement... 16:45:42 Voltage Offset Correction: v_off_ini = 424.453 uV, v_off_fin = 430.040 uV 16:45:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.889 uVs 16:45:42 Integrated Voltage Measurement... 16:45:51 Voltage Offset Correction: v_off_ini = 412.097 uV, v_off_fin = 404.901 uV 16:45:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.292 uVs 16:45:51 Integrated Voltage Measurement... 16:46:00 Voltage Offset Correction: v_off_ini = 405.712 uV, v_off_fin = 416.122 uV 16:46:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.036 uVs 16:46:00 Integrated Voltage Measurement... 16:46:09 Voltage Offset Correction: v_off_ini = 402.042 uV, v_off_fin = 401.793 uV 16:46:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.433 uVs 16:46:09 Integrated Voltage Measurement... 16:46:18 Voltage Offset Correction: v_off_ini = 421.369 uV, v_off_fin = 410.250 uV 16:46:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.863 uVs 16:46:22 I1Y Average and RMS of Measurements VT = -198.587 +- 9.242 uVs I1Y = -39.717 +- 1.848 uTm 16:46:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:46:30 Integrated Voltage Measurement... 16:46:39 Voltage Offset Correction: v_off_ini = 396.355 uV, v_off_fin = 396.061 uV 16:46:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.933 uVs 16:46:39 Integrated Voltage Measurement... 16:46:48 Voltage Offset Correction: v_off_ini = 412.619 uV, v_off_fin = 413.687 uV 16:46:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.053 uVs 16:46:48 Integrated Voltage Measurement... 16:46:57 Voltage Offset Correction: v_off_ini = 415.295 uV, v_off_fin = 397.450 uV 16:46:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -98.806 uVs 16:46:57 Integrated Voltage Measurement... 16:47:06 Voltage Offset Correction: v_off_ini = 414.029 uV, v_off_fin = 415.913 uV 16:47:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.326 uVs 16:47:06 Integrated Voltage Measurement... 16:47:15 Voltage Offset Correction: v_off_ini = 414.875 uV, v_off_fin = 400.624 uV 16:47:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.506 uVs 16:47:15 Integrated Voltage Measurement... 16:47:24 Voltage Offset Correction: v_off_ini = 395.255 uV, v_off_fin = 411.061 uV 16:47:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.155 uVs 16:47:26 I2X Average and RMS of Measurements VT = -92.297 +- 7.119 uVs I2X = 8.491 +- 0.655 uTm^2 16:47:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:47:34 Integrated Voltage Measurement... 16:47:43 Voltage Offset Correction: v_off_ini = 404.168 uV, v_off_fin = 406.550 uV 16:47:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.378 uVs 16:47:43 Integrated Voltage Measurement... 16:47:52 Voltage Offset Correction: v_off_ini = 412.582 uV, v_off_fin = 408.212 uV 16:47:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.744 uVs 16:47:52 Integrated Voltage Measurement... 16:48:01 Voltage Offset Correction: v_off_ini = 405.580 uV, v_off_fin = 408.532 uV 16:48:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.784 uVs 16:48:01 Integrated Voltage Measurement... 16:48:10 Voltage Offset Correction: v_off_ini = 421.496 uV, v_off_fin = 411.150 uV 16:48:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.318 uVs 16:48:10 Integrated Voltage Measurement... 16:48:19 Voltage Offset Correction: v_off_ini = 406.002 uV, v_off_fin = 399.363 uV 16:48:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.285 uVs 16:48:19 Integrated Voltage Measurement... 16:48:28 Voltage Offset Correction: v_off_ini = 408.042 uV, v_off_fin = 407.459 uV 16:48:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.495 uVs 16:48:31 I2Y Average and RMS of Measurements VT = -218.001 +- 8.091 uVs I2Y = -20.056 +- 0.744 uTm^2 16:48:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:48:39 Integrated Voltage Measurement... 16:48:48 Voltage Offset Correction: v_off_ini = 411.483 uV, v_off_fin = 396.418 uV 16:48:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.989 uVs 16:48:48 Integrated Voltage Measurement... 16:48:57 Voltage Offset Correction: v_off_ini = 400.534 uV, v_off_fin = 392.695 uV 16:48:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.341 uVs 16:48:57 Integrated Voltage Measurement... 16:49:06 Voltage Offset Correction: v_off_ini = 392.144 uV, v_off_fin = 394.709 uV 16:49:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.922 uVs 16:49:06 Integrated Voltage Measurement... 16:49:15 Voltage Offset Correction: v_off_ini = 382.218 uV, v_off_fin = 398.965 uV 16:49:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.176 uVs 16:49:16 Integrated Voltage Measurement... 16:49:24 Voltage Offset Correction: v_off_ini = 389.172 uV, v_off_fin = 390.013 uV 16:49:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.636 uVs 16:49:25 Integrated Voltage Measurement... 16:49:33 Voltage Offset Correction: v_off_ini = 381.429 uV, v_off_fin = 382.659 uV 16:49:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.152 uVs 16:49:38 I1X Average and RMS of Measurements VT = -68.869 +- 14.062 uVs I1X = 13.774 +- 2.813 uTm 16:49:40 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:49:44 Integrated Voltage Measurement... 16:49:53 Voltage Offset Correction: v_off_ini = 390.300 uV, v_off_fin = 383.625 uV 16:49:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -206.780 uVs 16:49:53 Integrated Voltage Measurement... 16:50:02 Voltage Offset Correction: v_off_ini = 402.893 uV, v_off_fin = 415.031 uV 16:50:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.977 uVs 16:50:02 Integrated Voltage Measurement... 16:50:11 Voltage Offset Correction: v_off_ini = 387.795 uV, v_off_fin = 387.077 uV 16:50:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.972 uVs 16:50:11 Integrated Voltage Measurement... 16:50:20 Voltage Offset Correction: v_off_ini = 391.621 uV, v_off_fin = 417.215 uV 16:50:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.346 uVs 16:50:20 Integrated Voltage Measurement... 16:50:29 Voltage Offset Correction: v_off_ini = 405.527 uV, v_off_fin = 393.762 uV 16:50:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.370 uVs 16:50:29 Integrated Voltage Measurement... 16:50:38 Voltage Offset Correction: v_off_ini = 402.213 uV, v_off_fin = 405.915 uV 16:50:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.817 uVs 16:50:43 I1Y Average and RMS of Measurements VT = -195.377 +- 9.398 uVs I1Y = -39.076 +- 1.880 uTm 16:50:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:50:50 Integrated Voltage Measurement... 16:50:59 Voltage Offset Correction: v_off_ini = 395.123 uV, v_off_fin = 396.245 uV 16:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.378 uVs 16:50:59 Integrated Voltage Measurement... 16:51:08 Voltage Offset Correction: v_off_ini = 406.688 uV, v_off_fin = 390.577 uV 16:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.631 uVs 16:51:08 Integrated Voltage Measurement... 16:51:17 Voltage Offset Correction: v_off_ini = 408.494 uV, v_off_fin = 400.452 uV 16:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.426 uVs 16:51:17 Integrated Voltage Measurement... 16:51:26 Voltage Offset Correction: v_off_ini = 412.858 uV, v_off_fin = 419.154 uV 16:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.989 uVs 16:51:26 Integrated Voltage Measurement... 16:51:35 Voltage Offset Correction: v_off_ini = 398.609 uV, v_off_fin = 382.813 uV 16:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.069 uVs 16:51:35 Integrated Voltage Measurement... 16:51:44 Voltage Offset Correction: v_off_ini = 422.097 uV, v_off_fin = 423.740 uV 16:51:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.300 uVs 16:51:47 I2X Average and RMS of Measurements VT = -70.799 +- 4.130 uVs I2X = 6.513 +- 0.380 uTm^2 16:51:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:51:54 Integrated Voltage Measurement... 16:52:03 Voltage Offset Correction: v_off_ini = 393.778 uV, v_off_fin = 398.183 uV 16:52:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.887 uVs 16:52:04 Integrated Voltage Measurement... 16:52:12 Voltage Offset Correction: v_off_ini = 388.470 uV, v_off_fin = 390.081 uV 16:52:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.271 uVs 16:52:13 Integrated Voltage Measurement... 16:52:22 Voltage Offset Correction: v_off_ini = 387.910 uV, v_off_fin = 402.180 uV 16:52:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.827 uVs 16:52:22 Integrated Voltage Measurement... 16:52:31 Voltage Offset Correction: v_off_ini = 401.839 uV, v_off_fin = 413.634 uV 16:52:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.959 uVs 16:52:31 Integrated Voltage Measurement... 16:52:40 Voltage Offset Correction: v_off_ini = 414.662 uV, v_off_fin = 399.042 uV 16:52:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.628 uVs 16:52:40 Integrated Voltage Measurement... 16:52:49 Voltage Offset Correction: v_off_ini = 412.840 uV, v_off_fin = 399.487 uV 16:52:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.438 uVs 16:52:51 I2Y Average and RMS of Measurements VT = -227.835 +- 8.945 uVs I2Y = -20.961 +- 0.823 uTm^2 16:52:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:53:03 Integrated Voltage Measurement... 16:53:12 Voltage Offset Correction: v_off_ini = 414.402 uV, v_off_fin = 408.206 uV 16:53:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.606 uVs 16:53:12 Integrated Voltage Measurement... 16:53:21 Voltage Offset Correction: v_off_ini = 406.865 uV, v_off_fin = 394.887 uV 16:53:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.775 uVs 16:53:21 Integrated Voltage Measurement... 16:53:30 Voltage Offset Correction: v_off_ini = 392.706 uV, v_off_fin = 385.916 uV 16:53:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.798 uVs 16:53:30 Integrated Voltage Measurement... 16:53:39 Voltage Offset Correction: v_off_ini = 383.203 uV, v_off_fin = 412.036 uV 16:53:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.572 uVs 16:53:39 Integrated Voltage Measurement... 16:53:48 Voltage Offset Correction: v_off_ini = 411.375 uV, v_off_fin = 400.714 uV 16:53:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.542 uVs 16:53:48 Integrated Voltage Measurement... 16:53:57 Voltage Offset Correction: v_off_ini = 389.247 uV, v_off_fin = 384.834 uV 16:53:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 87.790 uVs 16:54:01 I1X Average and RMS of Measurements VT = -86.847 +- 2.020 uVs I1X = 17.371 +- 0.404 uTm 16:54:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:54:08 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = 384.193 uV, v_off_fin = 397.363 uV 16:54:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.670 uVs 16:54:17 Integrated Voltage Measurement... 16:54:26 Voltage Offset Correction: v_off_ini = 409.472 uV, v_off_fin = 410.892 uV 16:54:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.058 uVs 16:54:26 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = 395.951 uV, v_off_fin = 376.074 uV 16:54:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.856 uVs 16:54:35 Integrated Voltage Measurement... 16:54:44 Voltage Offset Correction: v_off_ini = 405.755 uV, v_off_fin = 421.588 uV 16:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.169 uVs 16:54:44 Integrated Voltage Measurement... 16:54:53 Voltage Offset Correction: v_off_ini = 410.785 uV, v_off_fin = 386.413 uV 16:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.998 uVs 16:54:53 Integrated Voltage Measurement... 16:55:02 Voltage Offset Correction: v_off_ini = 390.223 uV, v_off_fin = 424.436 uV 16:55:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.422 uVs 16:55:06 I1Y Average and RMS of Measurements VT = -208.862 +- 7.240 uVs I1Y = -41.772 +- 1.448 uTm 16:55:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:55:11 Integrated Voltage Measurement... 16:55:20 Voltage Offset Correction: v_off_ini = 389.062 uV, v_off_fin = 383.660 uV 16:55:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.657 uVs 16:55:20 Integrated Voltage Measurement... 16:55:29 Voltage Offset Correction: v_off_ini = 405.713 uV, v_off_fin = 412.212 uV 16:55:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.324 uVs 16:55:29 Integrated Voltage Measurement... 16:55:38 Voltage Offset Correction: v_off_ini = 392.053 uV, v_off_fin = 387.930 uV 16:55:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.485 uVs 16:55:38 Integrated Voltage Measurement... 16:55:47 Voltage Offset Correction: v_off_ini = 388.232 uV, v_off_fin = 403.710 uV 16:55:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.316 uVs 16:55:47 Integrated Voltage Measurement... 16:55:56 Voltage Offset Correction: v_off_ini = 396.294 uV, v_off_fin = 403.353 uV 16:55:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.892 uVs 16:55:56 Integrated Voltage Measurement... 16:56:05 Voltage Offset Correction: v_off_ini = 400.339 uV, v_off_fin = 394.887 uV 16:56:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.673 uVs 16:56:08 I2X Average and RMS of Measurements VT = -91.058 +- 7.307 uVs I2X = 8.377 +- 0.672 uTm^2 16:56:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:56:13 Integrated Voltage Measurement... 16:56:22 Voltage Offset Correction: v_off_ini = 388.537 uV, v_off_fin = 387.510 uV 16:56:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.765 uVs 16:56:22 Integrated Voltage Measurement... 16:56:31 Voltage Offset Correction: v_off_ini = 391.239 uV, v_off_fin = 388.268 uV 16:56:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.218 uVs 16:56:31 Integrated Voltage Measurement... 16:56:40 Voltage Offset Correction: v_off_ini = 377.879 uV, v_off_fin = 379.368 uV 16:56:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.253 uVs 16:56:40 Integrated Voltage Measurement... 16:56:49 Voltage Offset Correction: v_off_ini = 386.202 uV, v_off_fin = 381.995 uV 16:56:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.803 uVs 16:56:49 Integrated Voltage Measurement... 16:56:58 Voltage Offset Correction: v_off_ini = 384.013 uV, v_off_fin = 376.011 uV 16:56:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.188 uVs 16:56:58 Integrated Voltage Measurement... 16:57:07 Voltage Offset Correction: v_off_ini = 380.127 uV, v_off_fin = 385.426 uV 16:57:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.657 uVs 16:57:09 I2Y Average and RMS of Measurements VT = -243.647 +- 8.695 uVs I2Y = -22.416 +- 0.800 uTm^2 16:57:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:57:18 Integrated Voltage Measurement... 16:57:27 Voltage Offset Correction: v_off_ini = 391.372 uV, v_off_fin = 383.596 uV 16:57:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.999 uVs 16:57:27 Integrated Voltage Measurement... 16:57:36 Voltage Offset Correction: v_off_ini = 405.221 uV, v_off_fin = 392.861 uV 16:57:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.033 uVs 16:57:36 Integrated Voltage Measurement... 16:57:45 Voltage Offset Correction: v_off_ini = 386.216 uV, v_off_fin = 392.867 uV 16:57:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.992 uVs 16:57:45 Integrated Voltage Measurement... 16:57:54 Voltage Offset Correction: v_off_ini = 397.571 uV, v_off_fin = 399.544 uV 16:57:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.535 uVs 16:57:54 Integrated Voltage Measurement... 16:58:03 Voltage Offset Correction: v_off_ini = 372.590 uV, v_off_fin = 379.110 uV 16:58:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.424 uVs 16:58:03 Integrated Voltage Measurement... 16:58:12 Voltage Offset Correction: v_off_ini = 395.245 uV, v_off_fin = 386.488 uV 16:58:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.791 uVs 16:58:16 I1X Average and RMS of Measurements VT = -87.962 +- 6.219 uVs I1X = 17.593 +- 1.244 uTm 16:58:18 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:58:23 Integrated Voltage Measurement... 16:58:32 Voltage Offset Correction: v_off_ini = 379.439 uV, v_off_fin = 383.218 uV 16:58:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.042 uVs 16:58:32 Integrated Voltage Measurement... 16:58:41 Voltage Offset Correction: v_off_ini = 384.027 uV, v_off_fin = 399.223 uV 16:58:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.960 uVs 16:58:41 Integrated Voltage Measurement... 16:58:50 Voltage Offset Correction: v_off_ini = 364.365 uV, v_off_fin = 394.082 uV 16:58:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.586 uVs 16:58:50 Integrated Voltage Measurement... 16:58:59 Voltage Offset Correction: v_off_ini = 375.674 uV, v_off_fin = 413.339 uV 16:58:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.309 uVs 16:58:59 Integrated Voltage Measurement... 16:59:08 Voltage Offset Correction: v_off_ini = 391.424 uV, v_off_fin = 374.695 uV 16:59:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.471 uVs 16:59:08 Integrated Voltage Measurement... 16:59:17 Voltage Offset Correction: v_off_ini = 378.246 uV, v_off_fin = 392.136 uV 16:59:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.084 uVs 16:59:21 I1Y Average and RMS of Measurements VT = -194.742 +- 2.591 uVs I1Y = -38.948 +- 0.518 uTm 16:59:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:59:26 Integrated Voltage Measurement... 16:59:35 Voltage Offset Correction: v_off_ini = 386.168 uV, v_off_fin = 375.228 uV 16:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.069 uVs 16:59:35 Integrated Voltage Measurement... 16:59:44 Voltage Offset Correction: v_off_ini = 370.235 uV, v_off_fin = 390.063 uV 16:59:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.839 uVs 16:59:44 Integrated Voltage Measurement... 16:59:53 Voltage Offset Correction: v_off_ini = 382.750 uV, v_off_fin = 376.008 uV 16:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.572 uVs 16:59:53 Integrated Voltage Measurement... 17:00:02 Voltage Offset Correction: v_off_ini = 385.874 uV, v_off_fin = 398.495 uV 17:00:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.062 uVs 17:00:02 Integrated Voltage Measurement... 17:00:11 Voltage Offset Correction: v_off_ini = 379.845 uV, v_off_fin = 384.766 uV 17:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.531 uVs 17:00:11 Integrated Voltage Measurement... 17:00:20 Voltage Offset Correction: v_off_ini = 387.275 uV, v_off_fin = 393.884 uV 17:00:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.641 uVs 17:00:23 I2X Average and RMS of Measurements VT = -104.619 +- 14.388 uVs I2X = 9.625 +- 1.324 uTm^2 17:00:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:00:28 Integrated Voltage Measurement... 17:00:37 Voltage Offset Correction: v_off_ini = 373.902 uV, v_off_fin = 368.170 uV 17:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.534 uVs 17:00:37 Integrated Voltage Measurement... 17:00:46 Voltage Offset Correction: v_off_ini = 355.775 uV, v_off_fin = 363.165 uV 17:00:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.952 uVs 17:00:46 Integrated Voltage Measurement... 17:00:55 Voltage Offset Correction: v_off_ini = 371.328 uV, v_off_fin = 363.480 uV 17:00:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.794 uVs 17:00:55 Integrated Voltage Measurement... 17:01:04 Voltage Offset Correction: v_off_ini = 348.094 uV, v_off_fin = 353.202 uV 17:01:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.272 uVs 17:01:04 Integrated Voltage Measurement... 17:01:13 Voltage Offset Correction: v_off_ini = 362.608 uV, v_off_fin = 365.990 uV 17:01:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.533 uVs 17:01:13 Integrated Voltage Measurement... 17:01:22 Voltage Offset Correction: v_off_ini = 355.298 uV, v_off_fin = 369.495 uV 17:01:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.801 uVs 17:01:24 I2Y Average and RMS of Measurements VT = -241.647 +- 6.460 uVs I2Y = -22.232 +- 0.594 uTm^2 17:01:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:33 Integrated Voltage Measurement... 17:01:42 Voltage Offset Correction: v_off_ini = 374.550 uV, v_off_fin = 376.384 uV 17:01:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.400 uVs 17:01:42 Integrated Voltage Measurement... 17:01:51 Voltage Offset Correction: v_off_ini = 396.128 uV, v_off_fin = 381.799 uV 17:01:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.595 uVs 17:01:51 Integrated Voltage Measurement... 17:02:00 Voltage Offset Correction: v_off_ini = 359.573 uV, v_off_fin = 361.952 uV 17:02:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.060 uVs 17:02:00 Integrated Voltage Measurement... 17:02:09 Voltage Offset Correction: v_off_ini = 372.171 uV, v_off_fin = 384.051 uV 17:02:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.182 uVs 17:02:09 Integrated Voltage Measurement... 17:02:18 Voltage Offset Correction: v_off_ini = 377.112 uV, v_off_fin = 370.395 uV 17:02:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.815 uVs 17:02:18 Integrated Voltage Measurement... 17:02:27 Voltage Offset Correction: v_off_ini = 373.949 uV, v_off_fin = 369.519 uV 17:02:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.590 uVs 17:02:31 I1X Average and RMS of Measurements VT = -97.107 +- 2.918 uVs I1X = 19.423 +- 0.583 uTm 17:02:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:38 Integrated Voltage Measurement... 17:02:47 Voltage Offset Correction: v_off_ini = 364.153 uV, v_off_fin = 350.964 uV 17:02:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.010 uVs 17:02:47 Integrated Voltage Measurement... 17:02:56 Voltage Offset Correction: v_off_ini = 363.408 uV, v_off_fin = 380.782 uV 17:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.416 uVs 17:02:56 Integrated Voltage Measurement... 17:03:05 Voltage Offset Correction: v_off_ini = 371.392 uV, v_off_fin = 368.193 uV 17:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.774 uVs 17:03:05 Integrated Voltage Measurement... 17:03:14 Voltage Offset Correction: v_off_ini = 369.419 uV, v_off_fin = 384.664 uV 17:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.351 uVs 17:03:14 Integrated Voltage Measurement... 17:03:23 Voltage Offset Correction: v_off_ini = 374.005 uV, v_off_fin = 358.840 uV 17:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.392 uVs 17:03:23 Integrated Voltage Measurement... 17:03:32 Voltage Offset Correction: v_off_ini = 374.389 uV, v_off_fin = 384.832 uV 17:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.580 uVs 17:03:36 I1Y Average and RMS of Measurements VT = -188.421 +- 7.401 uVs I1Y = -37.684 +- 1.480 uTm 17:03:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:41 Integrated Voltage Measurement... 17:03:50 Voltage Offset Correction: v_off_ini = 369.579 uV, v_off_fin = 365.093 uV 17:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.331 uVs 17:03:50 Integrated Voltage Measurement... 17:03:59 Voltage Offset Correction: v_off_ini = 375.544 uV, v_off_fin = 370.402 uV 17:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.088 uVs 17:03:59 Integrated Voltage Measurement... 17:04:08 Voltage Offset Correction: v_off_ini = 366.436 uV, v_off_fin = 364.535 uV 17:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.166 uVs 17:04:08 Integrated Voltage Measurement... 17:04:17 Voltage Offset Correction: v_off_ini = 368.986 uV, v_off_fin = 388.540 uV 17:04:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.416 uVs 17:04:17 Integrated Voltage Measurement... 17:04:26 Voltage Offset Correction: v_off_ini = 374.453 uV, v_off_fin = 370.884 uV 17:04:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.410 uVs 17:04:26 Integrated Voltage Measurement... 17:04:35 Voltage Offset Correction: v_off_ini = 396.866 uV, v_off_fin = 397.312 uV 17:04:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.669 uVs 17:04:38 I2X Average and RMS of Measurements VT = -89.847 +- 0.954 uVs I2X = 8.266 +- 0.088 uTm^2 17:04:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:43 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 393.334 uV, v_off_fin = 383.345 uV 17:04:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.131 uVs 17:04:52 Integrated Voltage Measurement... 17:05:01 Voltage Offset Correction: v_off_ini = 385.154 uV, v_off_fin = 364.806 uV 17:05:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.804 uVs 17:05:01 Integrated Voltage Measurement... 17:05:10 Voltage Offset Correction: v_off_ini = 381.377 uV, v_off_fin = 384.585 uV 17:05:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.425 uVs 17:05:10 Integrated Voltage Measurement... 17:05:19 Voltage Offset Correction: v_off_ini = 383.771 uV, v_off_fin = 395.181 uV 17:05:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.022 uVs 17:05:19 Integrated Voltage Measurement... 17:05:28 Voltage Offset Correction: v_off_ini = 392.848 uV, v_off_fin = 376.119 uV 17:05:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.288 uVs 17:05:28 Integrated Voltage Measurement... 17:05:37 Voltage Offset Correction: v_off_ini = 387.513 uV, v_off_fin = 386.238 uV 17:05:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.722 uVs 17:05:40 I2Y Average and RMS of Measurements VT = -229.065 +- 1.937 uVs I2Y = -21.074 +- 0.178 uTm^2 17:05:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:05:48 Integrated Voltage Measurement... 17:05:57 Voltage Offset Correction: v_off_ini = 396.533 uV, v_off_fin = 393.878 uV 17:05:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.548 uVs 17:05:57 Integrated Voltage Measurement... 17:06:06 Voltage Offset Correction: v_off_ini = 395.746 uV, v_off_fin = 398.463 uV 17:06:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.763 uVs 17:06:06 Integrated Voltage Measurement... 17:06:15 Voltage Offset Correction: v_off_ini = 399.478 uV, v_off_fin = 394.870 uV 17:06:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.114 uVs 17:06:15 Integrated Voltage Measurement... 17:06:24 Voltage Offset Correction: v_off_ini = 391.562 uV, v_off_fin = 411.266 uV 17:06:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.497 uVs 17:06:24 Integrated Voltage Measurement... 17:06:33 Voltage Offset Correction: v_off_ini = 412.041 uV, v_off_fin = 387.594 uV 17:06:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.396 uVs 17:06:33 Integrated Voltage Measurement... 17:06:42 Voltage Offset Correction: v_off_ini = 384.486 uV, v_off_fin = 384.478 uV 17:06:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.736 uVs 17:06:46 I1X Average and RMS of Measurements VT = -88.676 +- 9.745 uVs I1X = 17.736 +- 1.949 uTm 17:06:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:06:53 Integrated Voltage Measurement... 17:07:02 Voltage Offset Correction: v_off_ini = 392.797 uV, v_off_fin = 363.785 uV 17:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.219 uVs 17:07:02 Integrated Voltage Measurement... 17:07:11 Voltage Offset Correction: v_off_ini = 388.461 uV, v_off_fin = 389.289 uV 17:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.771 uVs 17:07:11 Integrated Voltage Measurement... 17:07:20 Voltage Offset Correction: v_off_ini = 384.657 uV, v_off_fin = 393.198 uV 17:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.525 uVs 17:07:20 Integrated Voltage Measurement... 17:07:29 Voltage Offset Correction: v_off_ini = 404.750 uV, v_off_fin = 384.878 uV 17:07:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.559 uVs 17:07:29 Integrated Voltage Measurement... 17:07:38 Voltage Offset Correction: v_off_ini = 396.368 uV, v_off_fin = 381.386 uV 17:07:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.446 uVs 17:07:38 Integrated Voltage Measurement... 17:07:47 Voltage Offset Correction: v_off_ini = 390.116 uV, v_off_fin = 383.467 uV 17:07:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.873 uVs 17:07:51 I1Y Average and RMS of Measurements VT = -187.232 +- 5.589 uVs I1Y = -37.445 +- 1.117 uTm 17:07:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:07:56 Integrated Voltage Measurement... 17:08:05 Voltage Offset Correction: v_off_ini = 374.203 uV, v_off_fin = 371.513 uV 17:08:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.475 uVs 17:08:05 Integrated Voltage Measurement... 17:08:14 Voltage Offset Correction: v_off_ini = 368.411 uV, v_off_fin = 380.623 uV 17:08:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.273 uVs 17:08:14 Integrated Voltage Measurement... 17:08:23 Voltage Offset Correction: v_off_ini = 370.760 uV, v_off_fin = 358.729 uV 17:08:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.043 uVs 17:08:24 Integrated Voltage Measurement... 17:08:33 Voltage Offset Correction: v_off_ini = 394.542 uV, v_off_fin = 392.731 uV 17:08:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.483 uVs 17:08:33 Integrated Voltage Measurement... 17:08:42 Voltage Offset Correction: v_off_ini = 390.350 uV, v_off_fin = 373.453 uV 17:08:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.225 uVs 17:08:42 Integrated Voltage Measurement... 17:08:51 Voltage Offset Correction: v_off_ini = 384.523 uV, v_off_fin = 382.468 uV 17:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.100 uVs 17:08:53 I2X Average and RMS of Measurements VT = -98.600 +- 1.393 uVs I2X = 9.071 +- 0.128 uTm^2 17:08:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:08:58 Integrated Voltage Measurement... 17:09:07 Voltage Offset Correction: v_off_ini = 378.162 uV, v_off_fin = 395.854 uV 17:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.966 uVs 17:09:07 Integrated Voltage Measurement... 17:09:16 Voltage Offset Correction: v_off_ini = 404.823 uV, v_off_fin = 392.548 uV 17:09:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 214.216 uVs 17:09:16 Integrated Voltage Measurement... 17:09:25 Voltage Offset Correction: v_off_ini = 387.493 uV, v_off_fin = 400.242 uV 17:09:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.976 uVs 17:09:25 Integrated Voltage Measurement... 17:09:34 Voltage Offset Correction: v_off_ini = 378.807 uV, v_off_fin = 387.582 uV 17:09:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.072 uVs 17:09:34 Integrated Voltage Measurement... 17:09:43 Voltage Offset Correction: v_off_ini = 381.232 uV, v_off_fin = 393.367 uV 17:09:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.567 uVs 17:09:43 Integrated Voltage Measurement... 17:09:52 Voltage Offset Correction: v_off_ini = 378.571 uV, v_off_fin = 378.606 uV 17:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.248 uVs 17:09:55 I2Y Average and RMS of Measurements VT = -222.841 +- 6.401 uVs I2Y = -20.502 +- 0.589 uTm^2 17:09:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:10:03 Integrated Voltage Measurement... 17:10:12 Voltage Offset Correction: v_off_ini = 382.410 uV, v_off_fin = 383.981 uV 17:10:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -103.145 uVs 17:10:12 Integrated Voltage Measurement... 17:10:21 Voltage Offset Correction: v_off_ini = 378.243 uV, v_off_fin = 380.893 uV 17:10:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.898 uVs 17:10:21 Integrated Voltage Measurement... 17:10:30 Voltage Offset Correction: v_off_ini = 382.072 uV, v_off_fin = 392.393 uV 17:10:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.226 uVs 17:10:30 Integrated Voltage Measurement... 17:10:39 Voltage Offset Correction: v_off_ini = 388.299 uV, v_off_fin = 399.225 uV 17:10:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.575 uVs 17:10:39 Integrated Voltage Measurement... 17:10:48 Voltage Offset Correction: v_off_ini = 379.356 uV, v_off_fin = 379.477 uV 17:10:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.738 uVs 17:10:48 Integrated Voltage Measurement... 17:10:57 Voltage Offset Correction: v_off_ini = 391.392 uV, v_off_fin = 398.938 uV 17:10:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.845 uVs 17:11:01 I1X Average and RMS of Measurements VT = -89.071 +- 2.155 uVs I1X = 17.815 +- 0.430 uTm 17:11:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:11:08 Integrated Voltage Measurement... 17:11:17 Voltage Offset Correction: v_off_ini = 409.185 uV, v_off_fin = 384.972 uV 17:11:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.221 uVs 17:11:17 Integrated Voltage Measurement... 17:11:26 Voltage Offset Correction: v_off_ini = 388.952 uV, v_off_fin = 392.475 uV 17:11:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.542 uVs 17:11:26 Integrated Voltage Measurement... 17:11:35 Voltage Offset Correction: v_off_ini = 391.624 uV, v_off_fin = 381.946 uV 17:11:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.150 uVs 17:11:35 Integrated Voltage Measurement... 17:11:44 Voltage Offset Correction: v_off_ini = 389.475 uV, v_off_fin = 389.639 uV 17:11:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.153 uVs 17:11:44 Integrated Voltage Measurement... 17:11:53 Voltage Offset Correction: v_off_ini = 367.247 uV, v_off_fin = 371.284 uV 17:11:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.776 uVs 17:11:53 Integrated Voltage Measurement... 17:12:02 Voltage Offset Correction: v_off_ini = 382.487 uV, v_off_fin = 400.297 uV 17:12:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.761 uVs 17:12:06 I1Y Average and RMS of Measurements VT = -183.601 +- 3.339 uVs I1Y = -36.718 +- 0.666 uTm 17:12:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:12:12 Integrated Voltage Measurement... 17:12:21 Voltage Offset Correction: v_off_ini = 379.389 uV, v_off_fin = 372.498 uV 17:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.709 uVs 17:12:21 Integrated Voltage Measurement... 17:12:30 Voltage Offset Correction: v_off_ini = 400.260 uV, v_off_fin = 395.541 uV 17:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.450 uVs 17:12:30 Integrated Voltage Measurement... 17:12:39 Voltage Offset Correction: v_off_ini = 379.525 uV, v_off_fin = 381.326 uV 17:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.255 uVs 17:12:39 Integrated Voltage Measurement... 17:12:48 Voltage Offset Correction: v_off_ini = 386.392 uV, v_off_fin = 418.000 uV 17:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.064 uVs 17:12:48 Integrated Voltage Measurement... 17:12:57 Voltage Offset Correction: v_off_ini = 434.710 uV, v_off_fin = 430.846 uV 17:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.665 uVs 17:12:57 Integrated Voltage Measurement... 17:13:06 Voltage Offset Correction: v_off_ini = 405.740 uV, v_off_fin = 439.851 uV 17:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.059 uVs 17:13:08 I2X Average and RMS of Measurements VT = -86.867 +- 6.447 uVs I2X = 7.992 +- 0.593 uTm^2 17:13:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:13:13 Integrated Voltage Measurement... 17:13:22 Voltage Offset Correction: v_off_ini = 408.137 uV, v_off_fin = 421.616 uV 17:13:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.923 uVs 17:13:22 Integrated Voltage Measurement... 17:13:31 Voltage Offset Correction: v_off_ini = 396.687 uV, v_off_fin = 399.451 uV 17:13:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.519 uVs 17:13:31 Integrated Voltage Measurement... 17:13:40 Voltage Offset Correction: v_off_ini = 392.868 uV, v_off_fin = 406.483 uV 17:13:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.923 uVs 17:13:41 Integrated Voltage Measurement... 17:13:50 Voltage Offset Correction: v_off_ini = 400.824 uV, v_off_fin = 409.036 uV 17:13:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.544 uVs 17:13:50 Integrated Voltage Measurement... 17:13:59 Voltage Offset Correction: v_off_ini = 422.830 uV, v_off_fin = 395.072 uV 17:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.673 uVs 17:13:59 Integrated Voltage Measurement... 17:14:08 Voltage Offset Correction: v_off_ini = 397.886 uV, v_off_fin = 406.484 uV 17:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.948 uVs 17:14:10 I2Y Average and RMS of Measurements VT = -215.755 +- 8.461 uVs I2Y = -19.849 +- 0.778 uTm^2 17:14:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:14:31 Integrated Voltage Measurement... 17:14:40 Voltage Offset Correction: v_off_ini = 420.024 uV, v_off_fin = 412.130 uV 17:14:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -122.879 uVs 17:14:40 Integrated Voltage Measurement... 17:14:49 Voltage Offset Correction: v_off_ini = 415.973 uV, v_off_fin = 440.858 uV 17:14:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.769 uVs 17:14:49 Integrated Voltage Measurement... 17:14:58 Voltage Offset Correction: v_off_ini = 426.957 uV, v_off_fin = 427.691 uV 17:14:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.733 uVs 17:14:58 Integrated Voltage Measurement... 17:15:07 Voltage Offset Correction: v_off_ini = 445.109 uV, v_off_fin = 428.531 uV 17:15:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.456 uVs 17:15:07 Integrated Voltage Measurement... 17:15:16 Voltage Offset Correction: v_off_ini = 423.667 uV, v_off_fin = 410.235 uV 17:15:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.226 uVs 17:15:16 Integrated Voltage Measurement... 17:15:25 Voltage Offset Correction: v_off_ini = 418.879 uV, v_off_fin = 417.983 uV 17:15:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.524 uVs 17:15:30 I1X Average and RMS of Measurements VT = -126.264 +- 11.543 uVs I1X = 25.254 +- 2.307 uTm 17:15:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:15:36 Integrated Voltage Measurement... 17:15:45 Voltage Offset Correction: v_off_ini = 413.586 uV, v_off_fin = 401.120 uV 17:15:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.404 uVs 17:15:45 Integrated Voltage Measurement... 17:15:54 Voltage Offset Correction: v_off_ini = 411.726 uV, v_off_fin = 436.324 uV 17:15:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.215 uVs 17:15:54 Integrated Voltage Measurement... 17:16:03 Voltage Offset Correction: v_off_ini = 437.190 uV, v_off_fin = 410.729 uV 17:16:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.764 uVs 17:16:03 Integrated Voltage Measurement... 17:16:12 Voltage Offset Correction: v_off_ini = 414.089 uV, v_off_fin = 412.092 uV 17:16:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.347 uVs 17:16:12 Integrated Voltage Measurement... 17:16:21 Voltage Offset Correction: v_off_ini = 424.373 uV, v_off_fin = 408.488 uV 17:16:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.987 uVs 17:16:21 Integrated Voltage Measurement... 17:16:30 Voltage Offset Correction: v_off_ini = 422.540 uV, v_off_fin = 426.625 uV 17:16:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.170 uVs 17:16:35 I1Y Average and RMS of Measurements VT = -205.315 +- 9.898 uVs I1Y = -41.062 +- 1.979 uTm 17:16:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:16:42 Integrated Voltage Measurement... 17:16:51 Voltage Offset Correction: v_off_ini = 423.184 uV, v_off_fin = 423.225 uV 17:16:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.919 uVs 17:16:51 Integrated Voltage Measurement... 17:17:00 Voltage Offset Correction: v_off_ini = 420.815 uV, v_off_fin = 438.497 uV 17:17:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.870 uVs 17:17:00 Integrated Voltage Measurement... 17:17:09 Voltage Offset Correction: v_off_ini = 432.121 uV, v_off_fin = 433.164 uV 17:17:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.411 uVs 17:17:09 Integrated Voltage Measurement... 17:17:18 Voltage Offset Correction: v_off_ini = 419.416 uV, v_off_fin = 441.883 uV 17:17:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.095 uVs 17:17:19 Integrated Voltage Measurement... 17:17:27 Voltage Offset Correction: v_off_ini = 419.564 uV, v_off_fin = 416.886 uV 17:17:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.302 uVs 17:17:28 Integrated Voltage Measurement... 17:17:37 Voltage Offset Correction: v_off_ini = 422.518 uV, v_off_fin = 421.587 uV 17:17:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.817 uVs 17:17:39 I2X Average and RMS of Measurements VT = -135.902 +- 1.921 uVs I2X = 12.503 +- 0.177 uTm^2 17:17:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:17:47 Integrated Voltage Measurement... 17:17:56 Voltage Offset Correction: v_off_ini = 405.437 uV, v_off_fin = 407.187 uV 17:17:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.287 uVs 17:17:56 Integrated Voltage Measurement... 17:18:05 Voltage Offset Correction: v_off_ini = 413.576 uV, v_off_fin = 421.213 uV 17:18:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.058 uVs 17:18:05 Integrated Voltage Measurement... 17:18:14 Voltage Offset Correction: v_off_ini = 396.766 uV, v_off_fin = 405.580 uV 17:18:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.435 uVs 17:18:14 Integrated Voltage Measurement... 17:18:23 Voltage Offset Correction: v_off_ini = 402.969 uV, v_off_fin = 408.357 uV 17:18:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.077 uVs 17:18:23 Integrated Voltage Measurement... 17:18:32 Voltage Offset Correction: v_off_ini = 421.947 uV, v_off_fin = 421.526 uV 17:18:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.561 uVs 17:18:32 Integrated Voltage Measurement... 17:18:41 Voltage Offset Correction: v_off_ini = 413.184 uV, v_off_fin = 422.010 uV 17:18:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.309 uVs 17:18:43 I2Y Average and RMS of Measurements VT = -234.121 +- 6.147 uVs I2Y = -21.539 +- 0.565 uTm^2 17:18:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:18:52 Integrated Voltage Measurement... 17:19:01 Voltage Offset Correction: v_off_ini = 419.893 uV, v_off_fin = 409.020 uV 17:19:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.442 uVs 17:19:01 Integrated Voltage Measurement... 17:19:10 Voltage Offset Correction: v_off_ini = 400.088 uV, v_off_fin = 410.487 uV 17:19:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.931 uVs 17:19:10 Integrated Voltage Measurement... 17:19:19 Voltage Offset Correction: v_off_ini = 410.268 uV, v_off_fin = 397.411 uV 17:19:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.513 uVs 17:19:19 Integrated Voltage Measurement... 17:19:28 Voltage Offset Correction: v_off_ini = 414.512 uV, v_off_fin = 402.452 uV 17:19:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.199 uVs 17:19:28 Integrated Voltage Measurement... 17:19:37 Voltage Offset Correction: v_off_ini = 425.085 uV, v_off_fin = 410.758 uV 17:19:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.454 uVs 17:19:37 Integrated Voltage Measurement... 17:19:46 Voltage Offset Correction: v_off_ini = 407.090 uV, v_off_fin = 415.493 uV 17:19:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.862 uVs 17:19:51 I1X Average and RMS of Measurements VT = -131.567 +- 7.844 uVs I1X = 26.314 +- 1.568 uTm 17:19:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:19:57 Integrated Voltage Measurement... 17:20:06 Voltage Offset Correction: v_off_ini = 412.282 uV, v_off_fin = 405.135 uV 17:20:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.636 uVs 17:20:06 Integrated Voltage Measurement... 17:20:15 Voltage Offset Correction: v_off_ini = 410.515 uV, v_off_fin = 414.632 uV 17:20:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.244 uVs 17:20:15 Integrated Voltage Measurement... 17:20:24 Voltage Offset Correction: v_off_ini = 405.806 uV, v_off_fin = 399.774 uV 17:20:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.186 uVs 17:20:24 Integrated Voltage Measurement... 17:20:33 Voltage Offset Correction: v_off_ini = 426.938 uV, v_off_fin = 417.876 uV 17:20:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.622 uVs 17:20:33 Integrated Voltage Measurement... 17:20:42 Voltage Offset Correction: v_off_ini = 408.337 uV, v_off_fin = 409.625 uV 17:20:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.059 uVs 17:20:42 Integrated Voltage Measurement... 17:20:51 Voltage Offset Correction: v_off_ini = 413.353 uV, v_off_fin = 429.807 uV 17:20:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.900 uVs 17:20:56 I1Y Average and RMS of Measurements VT = -204.775 +- 4.672 uVs I1Y = -40.955 +- 0.934 uTm 17:21:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:21:03 Integrated Voltage Measurement... 17:21:12 Voltage Offset Correction: v_off_ini = 402.381 uV, v_off_fin = 393.049 uV 17:21:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.658 uVs 17:21:12 Integrated Voltage Measurement... 17:21:21 Voltage Offset Correction: v_off_ini = 414.792 uV, v_off_fin = 421.276 uV 17:21:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.080 uVs 17:21:21 Integrated Voltage Measurement... 17:21:30 Voltage Offset Correction: v_off_ini = 413.707 uV, v_off_fin = 408.806 uV 17:21:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.240 uVs 17:21:30 Integrated Voltage Measurement... 17:21:39 Voltage Offset Correction: v_off_ini = 407.020 uV, v_off_fin = 411.084 uV 17:21:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.004 uVs 17:21:39 Integrated Voltage Measurement... 17:21:48 Voltage Offset Correction: v_off_ini = 399.319 uV, v_off_fin = 400.354 uV 17:21:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.636 uVs 17:21:48 Integrated Voltage Measurement... 17:21:57 Voltage Offset Correction: v_off_ini = 401.285 uV, v_off_fin = 400.751 uV 17:21:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.448 uVs 17:22:00 I2X Average and RMS of Measurements VT = -125.511 +- 7.137 uVs I2X = 11.547 +- 0.657 uTm^2 17:22:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:22:08 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = 406.694 uV, v_off_fin = 403.914 uV 17:22:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.995 uVs 17:22:17 Integrated Voltage Measurement... 17:22:26 Voltage Offset Correction: v_off_ini = 405.897 uV, v_off_fin = 412.120 uV 17:22:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.093 uVs 17:22:26 Integrated Voltage Measurement... 17:22:35 Voltage Offset Correction: v_off_ini = 404.418 uV, v_off_fin = 398.515 uV 17:22:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.412 uVs 17:22:35 Integrated Voltage Measurement... 17:22:44 Voltage Offset Correction: v_off_ini = 421.882 uV, v_off_fin = 419.429 uV 17:22:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.048 uVs 17:22:44 Integrated Voltage Measurement... 17:22:53 Voltage Offset Correction: v_off_ini = 409.034 uV, v_off_fin = 418.415 uV 17:22:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.482 uVs 17:22:53 Integrated Voltage Measurement... 17:23:02 Voltage Offset Correction: v_off_ini = 414.150 uV, v_off_fin = 417.948 uV 17:23:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.005 uVs 17:23:04 I2Y Average and RMS of Measurements VT = -232.672 +- 5.355 uVs I2Y = -21.406 +- 0.493 uTm^2 17:23:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:13 Integrated Voltage Measurement... 17:23:22 Voltage Offset Correction: v_off_ini = 418.814 uV, v_off_fin = 414.990 uV 17:23:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.199 uVs 17:23:22 Integrated Voltage Measurement... 17:23:31 Voltage Offset Correction: v_off_ini = 433.565 uV, v_off_fin = 424.634 uV 17:23:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.016 uVs 17:23:31 Integrated Voltage Measurement... 17:23:40 Voltage Offset Correction: v_off_ini = 425.741 uV, v_off_fin = 405.020 uV 17:23:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.770 uVs 17:23:40 Integrated Voltage Measurement... 17:23:49 Voltage Offset Correction: v_off_ini = 418.541 uV, v_off_fin = 423.760 uV 17:23:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.519 uVs 17:23:49 Integrated Voltage Measurement... 17:23:58 Voltage Offset Correction: v_off_ini = 402.751 uV, v_off_fin = 405.187 uV 17:23:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.877 uVs 17:23:58 Integrated Voltage Measurement... 17:24:07 Voltage Offset Correction: v_off_ini = 418.964 uV, v_off_fin = 418.639 uV 17:24:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.717 uVs 17:24:12 I1X Average and RMS of Measurements VT = -103.016 +- 9.902 uVs I1X = 20.604 +- 1.980 uTm 17:24:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:18 Integrated Voltage Measurement... 17:24:27 Voltage Offset Correction: v_off_ini = 403.699 uV, v_off_fin = 407.748 uV 17:24:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.284 uVs 17:24:27 Integrated Voltage Measurement... 17:24:36 Voltage Offset Correction: v_off_ini = 415.402 uV, v_off_fin = 423.446 uV 17:24:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.674 uVs 17:24:36 Integrated Voltage Measurement... 17:24:45 Voltage Offset Correction: v_off_ini = 419.171 uV, v_off_fin = 401.241 uV 17:24:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.225 uVs 17:24:45 Integrated Voltage Measurement... 17:24:54 Voltage Offset Correction: v_off_ini = 407.897 uV, v_off_fin = 431.693 uV 17:24:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.158 uVs 17:24:54 Integrated Voltage Measurement... 17:25:03 Voltage Offset Correction: v_off_ini = 418.589 uV, v_off_fin = 409.847 uV 17:25:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.831 uVs 17:25:03 Integrated Voltage Measurement... 17:25:12 Voltage Offset Correction: v_off_ini = 431.238 uV, v_off_fin = 433.168 uV 17:25:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.705 uVs 17:25:17 I1Y Average and RMS of Measurements VT = -204.980 +- 5.214 uVs I1Y = -40.996 +- 1.043 uTm 17:25:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:24 Integrated Voltage Measurement... 17:25:33 Voltage Offset Correction: v_off_ini = 415.399 uV, v_off_fin = 397.974 uV 17:25:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.193 uVs 17:25:34 Integrated Voltage Measurement... 17:25:42 Voltage Offset Correction: v_off_ini = 408.068 uV, v_off_fin = 419.490 uV 17:25:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.534 uVs 17:25:43 Integrated Voltage Measurement... 17:25:52 Voltage Offset Correction: v_off_ini = 428.849 uV, v_off_fin = 419.578 uV 17:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.301 uVs 17:25:52 Integrated Voltage Measurement... 17:26:01 Voltage Offset Correction: v_off_ini = 442.191 uV, v_off_fin = 427.888 uV 17:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.585 uVs 17:26:01 Integrated Voltage Measurement... 17:26:10 Voltage Offset Correction: v_off_ini = 421.992 uV, v_off_fin = 407.273 uV 17:26:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.222 uVs 17:26:10 Integrated Voltage Measurement... 17:26:19 Voltage Offset Correction: v_off_ini = 418.928 uV, v_off_fin = 444.076 uV 17:26:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.925 uVs 17:26:21 I2X Average and RMS of Measurements VT = -110.794 +- 7.730 uVs I2X = 10.193 +- 0.711 uTm^2 17:26:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:29 Integrated Voltage Measurement... 17:26:38 Voltage Offset Correction: v_off_ini = 432.689 uV, v_off_fin = 435.864 uV 17:26:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.483 uVs 17:26:38 Integrated Voltage Measurement... 17:26:47 Voltage Offset Correction: v_off_ini = 431.523 uV, v_off_fin = 432.423 uV 17:26:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.565 uVs 17:26:47 Integrated Voltage Measurement... 17:26:56 Voltage Offset Correction: v_off_ini = 426.592 uV, v_off_fin = 435.236 uV 17:26:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.698 uVs 17:26:56 Integrated Voltage Measurement... 17:27:05 Voltage Offset Correction: v_off_ini = 439.859 uV, v_off_fin = 433.650 uV 17:27:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.502 uVs 17:27:05 Integrated Voltage Measurement... 17:27:14 Voltage Offset Correction: v_off_ini = 411.200 uV, v_off_fin = 423.221 uV 17:27:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.297 uVs 17:27:14 Integrated Voltage Measurement... 17:27:23 Voltage Offset Correction: v_off_ini = 418.274 uV, v_off_fin = 414.037 uV 17:27:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.872 uVs 17:27:25 I2Y Average and RMS of Measurements VT = -238.569 +- 2.144 uVs I2Y = -21.948 +- 0.197 uTm^2 17:27:30 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:27:34 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = 423.515 uV, v_off_fin = 420.303 uV 17:27:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.452 uVs 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = 421.191 uV, v_off_fin = 417.925 uV 17:27:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.227 uVs 17:27:52 Integrated Voltage Measurement... 17:28:01 Voltage Offset Correction: v_off_ini = 415.877 uV, v_off_fin = 406.027 uV 17:28:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.583 uVs 17:28:01 Integrated Voltage Measurement... 17:28:10 Voltage Offset Correction: v_off_ini = 405.542 uV, v_off_fin = 409.416 uV 17:28:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.147 uVs 17:28:10 Integrated Voltage Measurement... 17:28:19 Voltage Offset Correction: v_off_ini = 413.423 uV, v_off_fin = 408.006 uV 17:28:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -102.091 uVs 17:28:19 Integrated Voltage Measurement... 17:28:28 Voltage Offset Correction: v_off_ini = 416.130 uV, v_off_fin = 421.048 uV 17:28:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.623 uVs 17:28:32 I1X Average and RMS of Measurements VT = -100.187 +- 0.625 uVs I1X = 20.038 +- 0.125 uTm 17:28:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:28:39 Integrated Voltage Measurement... 17:28:48 Voltage Offset Correction: v_off_ini = 407.424 uV, v_off_fin = 402.830 uV 17:28:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.548 uVs 17:28:48 Integrated Voltage Measurement... 17:28:57 Voltage Offset Correction: v_off_ini = 412.123 uV, v_off_fin = 421.323 uV 17:28:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.399 uVs 17:28:57 Integrated Voltage Measurement... 17:29:06 Voltage Offset Correction: v_off_ini = 406.018 uV, v_off_fin = 412.423 uV 17:29:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.886 uVs 17:29:06 Integrated Voltage Measurement... 17:29:15 Voltage Offset Correction: v_off_ini = 409.764 uV, v_off_fin = 423.294 uV 17:29:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.587 uVs 17:29:15 Integrated Voltage Measurement... 17:29:24 Voltage Offset Correction: v_off_ini = 406.248 uV, v_off_fin = 395.237 uV 17:29:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.836 uVs 17:29:24 Integrated Voltage Measurement... 17:29:33 Voltage Offset Correction: v_off_ini = 418.888 uV, v_off_fin = 414.051 uV 17:29:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.489 uVs 17:29:37 I1Y Average and RMS of Measurements VT = -210.124 +- 7.143 uVs I1Y = -42.025 +- 1.429 uTm 17:29:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:29:45 Integrated Voltage Measurement... 17:29:54 Voltage Offset Correction: v_off_ini = 398.091 uV, v_off_fin = 397.749 uV 17:29:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.724 uVs 17:29:54 Integrated Voltage Measurement... 17:30:03 Voltage Offset Correction: v_off_ini = 392.137 uV, v_off_fin = 412.895 uV 17:30:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.544 uVs 17:30:03 Integrated Voltage Measurement... 17:30:12 Voltage Offset Correction: v_off_ini = 405.622 uV, v_off_fin = 397.078 uV 17:30:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.342 uVs 17:30:12 Integrated Voltage Measurement... 17:30:21 Voltage Offset Correction: v_off_ini = 410.986 uV, v_off_fin = 412.348 uV 17:30:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.552 uVs 17:30:21 Integrated Voltage Measurement... 17:30:30 Voltage Offset Correction: v_off_ini = 396.866 uV, v_off_fin = 389.776 uV 17:30:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.784 uVs 17:30:30 Integrated Voltage Measurement... 17:30:39 Voltage Offset Correction: v_off_ini = 406.806 uV, v_off_fin = 401.331 uV 17:30:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.369 uVs 17:30:42 I2X Average and RMS of Measurements VT = -103.553 +- 9.087 uVs I2X = 9.527 +- 0.836 uTm^2 17:30:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:30:49 Integrated Voltage Measurement... 17:30:58 Voltage Offset Correction: v_off_ini = 394.194 uV, v_off_fin = 393.897 uV 17:30:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.426 uVs 17:30:58 Integrated Voltage Measurement... 17:31:07 Voltage Offset Correction: v_off_ini = 374.788 uV, v_off_fin = 405.353 uV 17:31:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 253.215 uVs 17:31:07 Integrated Voltage Measurement... 17:31:16 Voltage Offset Correction: v_off_ini = 402.694 uV, v_off_fin = 404.885 uV 17:31:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.161 uVs 17:31:16 Integrated Voltage Measurement... 17:31:25 Voltage Offset Correction: v_off_ini = 404.238 uV, v_off_fin = 411.788 uV 17:31:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.869 uVs 17:31:25 Integrated Voltage Measurement... 17:31:34 Voltage Offset Correction: v_off_ini = 399.261 uV, v_off_fin = 398.805 uV 17:31:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.946 uVs 17:31:34 Integrated Voltage Measurement... 17:31:43 Voltage Offset Correction: v_off_ini = 394.224 uV, v_off_fin = 385.009 uV 17:31:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.292 uVs 17:31:46 I2Y Average and RMS of Measurements VT = -240.318 +- 2.985 uVs I2Y = -22.110 +- 0.274 uTm^2 17:31:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:31:55 Integrated Voltage Measurement... 17:32:04 Voltage Offset Correction: v_off_ini = 396.795 uV, v_off_fin = 389.221 uV 17:32:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.529 uVs 17:32:04 Integrated Voltage Measurement... 17:32:13 Voltage Offset Correction: v_off_ini = 393.140 uV, v_off_fin = 394.036 uV 17:32:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.733 uVs 17:32:13 Integrated Voltage Measurement... 17:32:22 Voltage Offset Correction: v_off_ini = 386.001 uV, v_off_fin = 409.393 uV 17:32:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.349 uVs 17:32:22 Integrated Voltage Measurement... 17:32:31 Voltage Offset Correction: v_off_ini = 407.670 uV, v_off_fin = 415.810 uV 17:32:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.622 uVs 17:32:31 Integrated Voltage Measurement... 17:32:40 Voltage Offset Correction: v_off_ini = 405.556 uV, v_off_fin = 393.104 uV 17:32:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.535 uVs 17:32:40 Integrated Voltage Measurement... 17:32:49 Voltage Offset Correction: v_off_ini = 411.307 uV, v_off_fin = 400.856 uV 17:32:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.287 uVs 17:32:53 I1X Average and RMS of Measurements VT = -89.009 +- 5.206 uVs I1X = 17.802 +- 1.042 uTm 17:32:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:33:00 Integrated Voltage Measurement... 17:33:09 Voltage Offset Correction: v_off_ini = 398.971 uV, v_off_fin = 394.168 uV 17:33:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.949 uVs 17:33:09 Integrated Voltage Measurement... 17:33:18 Voltage Offset Correction: v_off_ini = 411.464 uV, v_off_fin = 429.126 uV 17:33:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.811 uVs 17:33:18 Integrated Voltage Measurement... 17:33:27 Voltage Offset Correction: v_off_ini = 420.885 uV, v_off_fin = 409.614 uV 17:33:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.332 uVs 17:33:27 Integrated Voltage Measurement... 17:33:36 Voltage Offset Correction: v_off_ini = 420.326 uV, v_off_fin = 424.373 uV 17:33:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.013 uVs 17:33:36 Integrated Voltage Measurement... 17:33:45 Voltage Offset Correction: v_off_ini = 414.565 uV, v_off_fin = 402.126 uV 17:33:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.466 uVs 17:33:45 Integrated Voltage Measurement... 17:33:54 Voltage Offset Correction: v_off_ini = 404.171 uV, v_off_fin = 414.865 uV 17:33:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.398 uVs 17:33:58 I1Y Average and RMS of Measurements VT = -209.662 +- 4.268 uVs I1Y = -41.932 +- 0.854 uTm 17:34:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:34:05 Integrated Voltage Measurement... 17:34:14 Voltage Offset Correction: v_off_ini = 406.573 uV, v_off_fin = 401.287 uV 17:34:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.093 uVs 17:34:15 Integrated Voltage Measurement... 17:34:23 Voltage Offset Correction: v_off_ini = 400.484 uV, v_off_fin = 407.001 uV 17:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.103 uVs 17:34:24 Integrated Voltage Measurement... 17:34:33 Voltage Offset Correction: v_off_ini = 402.526 uV, v_off_fin = 381.806 uV 17:34:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.171 uVs 17:34:33 Integrated Voltage Measurement... 17:34:42 Voltage Offset Correction: v_off_ini = 399.422 uV, v_off_fin = 404.455 uV 17:34:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.444 uVs 17:34:42 Integrated Voltage Measurement... 17:34:51 Voltage Offset Correction: v_off_ini = 398.785 uV, v_off_fin = 382.640 uV 17:34:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.245 uVs 17:34:51 Integrated Voltage Measurement... 17:35:00 Voltage Offset Correction: v_off_ini = 396.970 uV, v_off_fin = 396.812 uV 17:35:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.007 uVs 17:35:02 I2X Average and RMS of Measurements VT = -94.011 +- 7.694 uVs I2X = 8.649 +- 0.708 uTm^2 17:35:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:35:10 Integrated Voltage Measurement... 17:35:19 Voltage Offset Correction: v_off_ini = 396.693 uV, v_off_fin = 391.405 uV 17:35:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.795 uVs 17:35:19 Integrated Voltage Measurement... 17:35:28 Voltage Offset Correction: v_off_ini = 386.598 uV, v_off_fin = 395.713 uV 17:35:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.686 uVs 17:35:28 Integrated Voltage Measurement... 17:35:37 Voltage Offset Correction: v_off_ini = 390.438 uV, v_off_fin = 397.722 uV 17:35:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.114 uVs 17:35:37 Integrated Voltage Measurement... 17:35:46 Voltage Offset Correction: v_off_ini = 394.101 uV, v_off_fin = 406.245 uV 17:35:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.026 uVs 17:35:46 Integrated Voltage Measurement... 17:35:55 Voltage Offset Correction: v_off_ini = 405.239 uV, v_off_fin = 402.650 uV 17:35:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.877 uVs 17:35:55 Integrated Voltage Measurement... 17:36:04 Voltage Offset Correction: v_off_ini = 411.962 uV, v_off_fin = 408.464 uV 17:36:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.614 uVs 17:36:06 I2Y Average and RMS of Measurements VT = -248.852 +- 3.675 uVs I2Y = -22.894 +- 0.338 uTm^2 17:36:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:36:18 Integrated Voltage Measurement... 17:36:27 Voltage Offset Correction: v_off_ini = 399.428 uV, v_off_fin = 399.199 uV 17:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -130.198 uVs 17:36:27 Integrated Voltage Measurement... 17:36:36 Voltage Offset Correction: v_off_ini = 376.681 uV, v_off_fin = 398.501 uV 17:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.957 uVs 17:36:36 Integrated Voltage Measurement... 17:36:45 Voltage Offset Correction: v_off_ini = 407.260 uV, v_off_fin = 386.610 uV 17:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.953 uVs 17:36:45 Integrated Voltage Measurement... 17:36:54 Voltage Offset Correction: v_off_ini = 401.622 uV, v_off_fin = 408.017 uV 17:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.753 uVs 17:36:54 Integrated Voltage Measurement... 17:37:03 Voltage Offset Correction: v_off_ini = 390.559 uV, v_off_fin = 393.240 uV 17:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.051 uVs 17:37:03 Integrated Voltage Measurement... 17:37:12 Voltage Offset Correction: v_off_ini = 381.695 uV, v_off_fin = 378.688 uV 17:37:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.563 uVs 17:37:16 I1X Average and RMS of Measurements VT = -111.412 +- 6.092 uVs I1X = 22.283 +- 1.219 uTm 17:37:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:37:23 Integrated Voltage Measurement... 17:37:32 Voltage Offset Correction: v_off_ini = 376.299 uV, v_off_fin = 369.302 uV 17:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.140 uVs 17:37:32 Integrated Voltage Measurement... 17:37:41 Voltage Offset Correction: v_off_ini = 388.492 uV, v_off_fin = 377.361 uV 17:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.487 uVs 17:37:41 Integrated Voltage Measurement... 17:37:50 Voltage Offset Correction: v_off_ini = 394.794 uV, v_off_fin = 382.590 uV 17:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.984 uVs 17:37:50 Integrated Voltage Measurement... 17:37:59 Voltage Offset Correction: v_off_ini = 387.016 uV, v_off_fin = 391.532 uV 17:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.548 uVs 17:37:59 Integrated Voltage Measurement... 17:38:08 Voltage Offset Correction: v_off_ini = 399.098 uV, v_off_fin = 387.745 uV 17:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.329 uVs 17:38:08 Integrated Voltage Measurement... 17:38:17 Voltage Offset Correction: v_off_ini = 388.293 uV, v_off_fin = 397.367 uV 17:38:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.510 uVs 17:38:21 I1Y Average and RMS of Measurements VT = -217.833 +- 7.967 uVs I1Y = -43.567 +- 1.593 uTm 17:38:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:38:26 Integrated Voltage Measurement... 17:38:35 Voltage Offset Correction: v_off_ini = 379.332 uV, v_off_fin = 378.817 uV 17:38:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.415 uVs 17:38:35 Integrated Voltage Measurement... 17:38:44 Voltage Offset Correction: v_off_ini = 399.627 uV, v_off_fin = 406.548 uV 17:38:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.988 uVs 17:38:44 Integrated Voltage Measurement... 17:38:53 Voltage Offset Correction: v_off_ini = 388.071 uV, v_off_fin = 388.242 uV 17:38:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -100.287 uVs 17:38:54 Integrated Voltage Measurement... 17:39:02 Voltage Offset Correction: v_off_ini = 402.688 uV, v_off_fin = 407.753 uV 17:39:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 102.483 uVs 17:39:03 Integrated Voltage Measurement... 17:39:11 Voltage Offset Correction: v_off_ini = 392.750 uV, v_off_fin = 385.626 uV 17:39:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.774 uVs 17:39:12 Integrated Voltage Measurement... 17:39:21 Voltage Offset Correction: v_off_ini = 390.436 uV, v_off_fin = 382.961 uV 17:39:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.084 uVs 17:39:23 I2X Average and RMS of Measurements VT = -98.172 +- 10.746 uVs I2X = 9.032 +- 0.989 uTm^2 17:39:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:39:28 Integrated Voltage Measurement... 17:39:37 Voltage Offset Correction: v_off_ini = 374.230 uV, v_off_fin = 377.997 uV 17:39:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.838 uVs 17:39:37 Integrated Voltage Measurement... 17:39:46 Voltage Offset Correction: v_off_ini = 383.630 uV, v_off_fin = 371.211 uV 17:39:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.931 uVs 17:39:46 Integrated Voltage Measurement... 17:39:55 Voltage Offset Correction: v_off_ini = 377.326 uV, v_off_fin = 379.260 uV 17:39:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.836 uVs 17:39:55 Integrated Voltage Measurement... 17:40:04 Voltage Offset Correction: v_off_ini = 367.287 uV, v_off_fin = 386.953 uV 17:40:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 219.335 uVs 17:40:04 Integrated Voltage Measurement... 17:40:13 Voltage Offset Correction: v_off_ini = 386.174 uV, v_off_fin = 391.235 uV 17:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.343 uVs 17:40:13 Integrated Voltage Measurement... 17:40:22 Voltage Offset Correction: v_off_ini = 388.634 uV, v_off_fin = 381.711 uV 17:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.097 uVs 17:40:25 I2Y Average and RMS of Measurements VT = -239.897 +- 10.370 uVs I2Y = -22.071 +- 0.954 uTm^2 17:40:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:40:33 Integrated Voltage Measurement... 17:40:42 Voltage Offset Correction: v_off_ini = 407.198 uV, v_off_fin = 400.527 uV 17:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.294 uVs 17:40:42 Integrated Voltage Measurement... 17:40:51 Voltage Offset Correction: v_off_ini = 398.443 uV, v_off_fin = 387.039 uV 17:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.097 uVs 17:40:51 Integrated Voltage Measurement... 17:41:00 Voltage Offset Correction: v_off_ini = 383.682 uV, v_off_fin = 374.162 uV 17:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.511 uVs 17:41:00 Integrated Voltage Measurement... 17:41:09 Voltage Offset Correction: v_off_ini = 366.332 uV, v_off_fin = 396.757 uV 17:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.717 uVs 17:41:09 Integrated Voltage Measurement... 17:41:18 Voltage Offset Correction: v_off_ini = 376.881 uV, v_off_fin = 373.142 uV 17:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.313 uVs 17:41:18 Integrated Voltage Measurement... 17:41:27 Voltage Offset Correction: v_off_ini = 372.645 uV, v_off_fin = 384.313 uV 17:41:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.217 uVs 17:41:31 I1X Average and RMS of Measurements VT = -110.191 +- 6.476 uVs I1X = 22.038 +- 1.295 uTm 17:41:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:41:38 Integrated Voltage Measurement... 17:41:47 Voltage Offset Correction: v_off_ini = 378.584 uV, v_off_fin = 378.019 uV 17:41:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.524 uVs 17:41:47 Integrated Voltage Measurement... 17:41:56 Voltage Offset Correction: v_off_ini = 397.911 uV, v_off_fin = 404.660 uV 17:41:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.671 uVs 17:41:56 Integrated Voltage Measurement... 17:42:05 Voltage Offset Correction: v_off_ini = 378.309 uV, v_off_fin = 364.074 uV 17:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.896 uVs 17:42:05 Integrated Voltage Measurement... 17:42:14 Voltage Offset Correction: v_off_ini = 369.604 uV, v_off_fin = 386.566 uV 17:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.825 uVs 17:42:14 Integrated Voltage Measurement... 17:42:23 Voltage Offset Correction: v_off_ini = 362.967 uV, v_off_fin = 365.185 uV 17:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.350 uVs 17:42:23 Integrated Voltage Measurement... 17:42:32 Voltage Offset Correction: v_off_ini = 378.566 uV, v_off_fin = 389.768 uV 17:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.086 uVs 17:42:36 I1Y Average and RMS of Measurements VT = -204.892 +- 4.729 uVs I1Y = -40.978 +- 0.946 uTm 17:42:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:42:41 Integrated Voltage Measurement... 17:42:50 Voltage Offset Correction: v_off_ini = 376.235 uV, v_off_fin = 376.934 uV 17:42:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.257 uVs 17:42:50 Integrated Voltage Measurement... 17:42:59 Voltage Offset Correction: v_off_ini = 384.207 uV, v_off_fin = 399.666 uV 17:42:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.820 uVs 17:42:59 Integrated Voltage Measurement... 17:43:08 Voltage Offset Correction: v_off_ini = 384.919 uV, v_off_fin = 366.644 uV 17:43:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.470 uVs 17:43:08 Integrated Voltage Measurement... 17:43:17 Voltage Offset Correction: v_off_ini = 383.962 uV, v_off_fin = 393.425 uV 17:43:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.629 uVs 17:43:17 Integrated Voltage Measurement... 17:43:26 Voltage Offset Correction: v_off_ini = 401.105 uV, v_off_fin = 396.833 uV 17:43:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.381 uVs 17:43:26 Integrated Voltage Measurement... 17:43:35 Voltage Offset Correction: v_off_ini = 391.309 uV, v_off_fin = 392.390 uV 17:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.462 uVs 17:43:38 I2X Average and RMS of Measurements VT = -112.170 +- 1.987 uVs I2X = 10.320 +- 0.183 uTm^2 17:43:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:43:43 Integrated Voltage Measurement... 17:43:52 Voltage Offset Correction: v_off_ini = 392.822 uV, v_off_fin = 380.584 uV 17:43:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.117 uVs 17:43:52 Integrated Voltage Measurement... 17:44:01 Voltage Offset Correction: v_off_ini = 379.293 uV, v_off_fin = 380.256 uV 17:44:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 264.234 uVs 17:44:01 Integrated Voltage Measurement... 17:44:10 Voltage Offset Correction: v_off_ini = 378.092 uV, v_off_fin = 388.834 uV 17:44:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -229.684 uVs 17:44:10 Integrated Voltage Measurement... 17:44:19 Voltage Offset Correction: v_off_ini = 396.865 uV, v_off_fin = 384.956 uV 17:44:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.801 uVs 17:44:19 Integrated Voltage Measurement... 17:44:28 Voltage Offset Correction: v_off_ini = 384.426 uV, v_off_fin = 379.195 uV 17:44:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.251 uVs 17:44:28 Integrated Voltage Measurement... 17:44:37 Voltage Offset Correction: v_off_ini = 372.031 uV, v_off_fin = 390.654 uV 17:44:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.510 uVs 17:44:40 I2Y Average and RMS of Measurements VT = -247.100 +- 6.771 uVs I2Y = -22.734 +- 0.623 uTm^2 17:44:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:48 Integrated Voltage Measurement... 17:44:57 Voltage Offset Correction: v_off_ini = 391.105 uV, v_off_fin = 384.194 uV 17:44:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -122.224 uVs 17:44:57 Integrated Voltage Measurement... 17:45:06 Voltage Offset Correction: v_off_ini = 388.163 uV, v_off_fin = 369.554 uV 17:45:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.289 uVs 17:45:06 Integrated Voltage Measurement... 17:45:15 Voltage Offset Correction: v_off_ini = 371.350 uV, v_off_fin = 373.540 uV 17:45:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.441 uVs 17:45:15 Integrated Voltage Measurement... 17:45:24 Voltage Offset Correction: v_off_ini = 385.192 uV, v_off_fin = 368.191 uV 17:45:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.002 uVs 17:45:24 Integrated Voltage Measurement... 17:45:33 Voltage Offset Correction: v_off_ini = 382.480 uV, v_off_fin = 375.643 uV 17:45:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.730 uVs 17:45:33 Integrated Voltage Measurement... 17:45:42 Voltage Offset Correction: v_off_ini = 373.829 uV, v_off_fin = 371.342 uV 17:45:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.474 uVs 17:45:46 I1X Average and RMS of Measurements VT = -123.860 +- 10.982 uVs I1X = 24.774 +- 2.195 uTm 17:45:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:53 Integrated Voltage Measurement... 17:46:02 Voltage Offset Correction: v_off_ini = 374.526 uV, v_off_fin = 360.674 uV 17:46:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.001 uVs 17:46:02 Integrated Voltage Measurement... 17:46:11 Voltage Offset Correction: v_off_ini = 377.307 uV, v_off_fin = 389.742 uV 17:46:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.917 uVs 17:46:11 Integrated Voltage Measurement... 17:46:20 Voltage Offset Correction: v_off_ini = 392.124 uV, v_off_fin = 381.106 uV 17:46:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.114 uVs 17:46:20 Integrated Voltage Measurement... 17:46:29 Voltage Offset Correction: v_off_ini = 387.048 uV, v_off_fin = 390.854 uV 17:46:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.015 uVs 17:46:29 Integrated Voltage Measurement... 17:46:38 Voltage Offset Correction: v_off_ini = 387.485 uV, v_off_fin = 359.599 uV 17:46:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.536 uVs 17:46:38 Integrated Voltage Measurement... 17:46:47 Voltage Offset Correction: v_off_ini = 378.496 uV, v_off_fin = 387.157 uV 17:46:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.575 uVs 17:46:51 I1Y Average and RMS of Measurements VT = -196.193 +- 6.883 uVs I1Y = -39.239 +- 1.377 uTm 17:46:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:56 Integrated Voltage Measurement... 17:47:05 Voltage Offset Correction: v_off_ini = 379.689 uV, v_off_fin = 394.026 uV 17:47:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.746 uVs 17:47:05 Integrated Voltage Measurement... 17:47:14 Voltage Offset Correction: v_off_ini = 409.943 uV, v_off_fin = 400.751 uV 17:47:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.201 uVs 17:47:14 Integrated Voltage Measurement... 17:47:23 Voltage Offset Correction: v_off_ini = 400.728 uV, v_off_fin = 381.865 uV 17:47:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.910 uVs 17:47:24 Integrated Voltage Measurement... 17:47:32 Voltage Offset Correction: v_off_ini = 399.712 uV, v_off_fin = 410.003 uV 17:47:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.343 uVs 17:47:33 Integrated Voltage Measurement... 17:47:42 Voltage Offset Correction: v_off_ini = 399.306 uV, v_off_fin = 393.250 uV 17:47:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.579 uVs 17:47:42 Integrated Voltage Measurement... 17:47:51 Voltage Offset Correction: v_off_ini = 384.823 uV, v_off_fin = 400.051 uV 17:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.511 uVs 17:47:53 I2X Average and RMS of Measurements VT = -115.882 +- 9.747 uVs I2X = 10.661 +- 0.897 uTm^2 17:47:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:47:58 Integrated Voltage Measurement... 17:48:07 Voltage Offset Correction: v_off_ini = 398.970 uV, v_off_fin = 391.895 uV 17:48:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.534 uVs 17:48:07 Integrated Voltage Measurement... 17:48:16 Voltage Offset Correction: v_off_ini = 384.402 uV, v_off_fin = 377.954 uV 17:48:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.568 uVs 17:48:16 Integrated Voltage Measurement... 17:48:25 Voltage Offset Correction: v_off_ini = 384.482 uV, v_off_fin = 386.422 uV 17:48:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.152 uVs 17:48:25 Integrated Voltage Measurement... 17:48:34 Voltage Offset Correction: v_off_ini = 382.087 uV, v_off_fin = 389.036 uV 17:48:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.401 uVs 17:48:34 Integrated Voltage Measurement... 17:48:43 Voltage Offset Correction: v_off_ini = 371.455 uV, v_off_fin = 389.427 uV 17:48:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.653 uVs 17:48:43 Integrated Voltage Measurement... 17:48:52 Voltage Offset Correction: v_off_ini = 395.790 uV, v_off_fin = 387.403 uV 17:48:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.831 uVs 17:48:55 I2Y Average and RMS of Measurements VT = -242.690 +- 12.349 uVs I2Y = -22.327 +- 1.136 uTm^2 17:48:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:49:03 Integrated Voltage Measurement... 17:49:12 Voltage Offset Correction: v_off_ini = 392.398 uV, v_off_fin = 384.665 uV 17:49:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.491 uVs 17:49:12 Integrated Voltage Measurement... 17:49:21 Voltage Offset Correction: v_off_ini = 384.248 uV, v_off_fin = 388.436 uV 17:49:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.470 uVs 17:49:21 Integrated Voltage Measurement... 17:49:30 Voltage Offset Correction: v_off_ini = 394.389 uV, v_off_fin = 376.648 uV 17:49:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.427 uVs 17:49:30 Integrated Voltage Measurement... 17:49:39 Voltage Offset Correction: v_off_ini = 406.506 uV, v_off_fin = 411.138 uV 17:49:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.901 uVs 17:49:39 Integrated Voltage Measurement... 17:49:48 Voltage Offset Correction: v_off_ini = 396.926 uV, v_off_fin = 386.839 uV 17:49:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.413 uVs 17:49:48 Integrated Voltage Measurement... 17:49:57 Voltage Offset Correction: v_off_ini = 382.393 uV, v_off_fin = 395.937 uV 17:49:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.619 uVs 17:50:01 I1X Average and RMS of Measurements VT = -107.387 +- 6.445 uVs I1X = 21.478 +- 1.288 uTm 17:50:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:50:08 Integrated Voltage Measurement... 17:50:17 Voltage Offset Correction: v_off_ini = 388.299 uV, v_off_fin = 362.931 uV 17:50:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.594 uVs 17:50:17 Integrated Voltage Measurement... 17:50:26 Voltage Offset Correction: v_off_ini = 361.750 uV, v_off_fin = 379.368 uV 17:50:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.101 uVs 17:50:26 Integrated Voltage Measurement... 17:50:35 Voltage Offset Correction: v_off_ini = 377.134 uV, v_off_fin = 381.019 uV 17:50:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.469 uVs 17:50:35 Integrated Voltage Measurement... 17:50:44 Voltage Offset Correction: v_off_ini = 403.494 uV, v_off_fin = 397.016 uV 17:50:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.619 uVs 17:50:44 Integrated Voltage Measurement... 17:50:53 Voltage Offset Correction: v_off_ini = 395.505 uV, v_off_fin = 379.199 uV 17:50:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.973 uVs 17:50:53 Integrated Voltage Measurement... 17:51:02 Voltage Offset Correction: v_off_ini = 387.492 uV, v_off_fin = 390.804 uV 17:51:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.769 uVs 17:51:06 I1Y Average and RMS of Measurements VT = -198.587 +- 12.650 uVs I1Y = -39.717 +- 2.530 uTm 17:51:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:51:12 Integrated Voltage Measurement... 17:51:21 Voltage Offset Correction: v_off_ini = 395.336 uV, v_off_fin = 385.383 uV 17:51:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.082 uVs 17:51:21 Integrated Voltage Measurement... 17:51:30 Voltage Offset Correction: v_off_ini = 400.160 uV, v_off_fin = 402.577 uV 17:51:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.713 uVs 17:51:30 Integrated Voltage Measurement... 17:51:39 Voltage Offset Correction: v_off_ini = 401.166 uV, v_off_fin = 387.245 uV 17:51:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.219 uVs 17:51:39 Integrated Voltage Measurement... 17:51:48 Voltage Offset Correction: v_off_ini = 409.872 uV, v_off_fin = 401.444 uV 17:51:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.972 uVs 17:51:48 Integrated Voltage Measurement... 17:51:57 Voltage Offset Correction: v_off_ini = 394.534 uV, v_off_fin = 391.655 uV 17:51:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.485 uVs 17:51:57 Integrated Voltage Measurement... 17:52:06 Voltage Offset Correction: v_off_ini = 384.787 uV, v_off_fin = 386.333 uV 17:52:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.039 uVs 17:52:08 I2X Average and RMS of Measurements VT = -111.585 +- 8.976 uVs I2X = 10.266 +- 0.826 uTm^2 17:52:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:52:13 Integrated Voltage Measurement... 17:52:22 Voltage Offset Correction: v_off_ini = 393.914 uV, v_off_fin = 380.914 uV 17:52:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.244 uVs 17:52:22 Integrated Voltage Measurement... 17:52:31 Voltage Offset Correction: v_off_ini = 383.965 uV, v_off_fin = 390.963 uV 17:52:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.786 uVs 17:52:31 Integrated Voltage Measurement... 17:52:40 Voltage Offset Correction: v_off_ini = 381.544 uV, v_off_fin = 393.885 uV 17:52:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.622 uVs 17:52:41 Integrated Voltage Measurement... 17:52:50 Voltage Offset Correction: v_off_ini = 391.709 uV, v_off_fin = 383.301 uV 17:52:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.651 uVs 17:52:50 Integrated Voltage Measurement... 17:52:59 Voltage Offset Correction: v_off_ini = 390.234 uV, v_off_fin = 383.925 uV 17:52:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.875 uVs 17:52:59 Integrated Voltage Measurement... 17:53:08 Voltage Offset Correction: v_off_ini = 394.967 uV, v_off_fin = 388.316 uV 17:53:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.207 uVs 17:53:10 I2Y Average and RMS of Measurements VT = -233.064 +- 3.509 uVs I2Y = -21.442 +- 0.323 uTm^2 17:53:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:53:18 Integrated Voltage Measurement... 17:53:27 Voltage Offset Correction: v_off_ini = 370.287 uV, v_off_fin = 352.324 uV 17:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.832 uVs 17:53:27 Integrated Voltage Measurement... 17:53:36 Voltage Offset Correction: v_off_ini = 360.471 uV, v_off_fin = 377.994 uV 17:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.345 uVs 17:53:36 Integrated Voltage Measurement... 17:53:45 Voltage Offset Correction: v_off_ini = 365.648 uV, v_off_fin = 364.081 uV 17:53:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.482 uVs 17:53:45 Integrated Voltage Measurement... 17:53:54 Voltage Offset Correction: v_off_ini = 382.453 uV, v_off_fin = 386.179 uV 17:53:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.264 uVs 17:53:54 Integrated Voltage Measurement... 17:54:03 Voltage Offset Correction: v_off_ini = 384.318 uV, v_off_fin = 386.050 uV 17:54:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.885 uVs 17:54:03 Integrated Voltage Measurement... 17:54:12 Voltage Offset Correction: v_off_ini = 383.533 uV, v_off_fin = 382.806 uV 17:54:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.375 uVs 17:54:17 I1X Average and RMS of Measurements VT = -97.364 +- 2.318 uVs I1X = 19.473 +- 0.463 uTm 17:54:19 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:54:23 Integrated Voltage Measurement... 17:54:32 Voltage Offset Correction: v_off_ini = 380.315 uV, v_off_fin = 390.155 uV 17:54:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.086 uVs 17:54:32 Integrated Voltage Measurement... 17:54:41 Voltage Offset Correction: v_off_ini = 384.296 uV, v_off_fin = 397.790 uV 17:54:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.175 uVs 17:54:41 Integrated Voltage Measurement... 17:54:50 Voltage Offset Correction: v_off_ini = 399.564 uV, v_off_fin = 391.824 uV 17:54:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.117 uVs 17:54:50 Integrated Voltage Measurement... 17:54:59 Voltage Offset Correction: v_off_ini = 394.888 uV, v_off_fin = 397.005 uV 17:54:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.134 uVs 17:54:59 Integrated Voltage Measurement... 17:55:08 Voltage Offset Correction: v_off_ini = 391.372 uV, v_off_fin = 396.310 uV 17:55:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.570 uVs 17:55:08 Integrated Voltage Measurement... 17:55:17 Voltage Offset Correction: v_off_ini = 392.478 uV, v_off_fin = 398.935 uV 17:55:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.947 uVs 17:55:22 I1Y Average and RMS of Measurements VT = -190.505 +- 5.226 uVs I1Y = -38.100 +- 1.044 uTm 17:55:24 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:55:27 Integrated Voltage Measurement... 17:55:36 Voltage Offset Correction: v_off_ini = 433.739 uV, v_off_fin = 420.554 uV 17:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.670 uVs 17:55:36 Integrated Voltage Measurement... 17:55:45 Voltage Offset Correction: v_off_ini = 414.430 uV, v_off_fin = 429.738 uV 17:55:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.747 uVs 17:55:45 Integrated Voltage Measurement... 17:55:54 Voltage Offset Correction: v_off_ini = 413.460 uV, v_off_fin = 388.519 uV 17:55:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.538 uVs 17:55:54 Integrated Voltage Measurement... 17:56:03 Voltage Offset Correction: v_off_ini = 396.979 uV, v_off_fin = 401.551 uV 17:56:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.141 uVs 17:56:03 Integrated Voltage Measurement... 17:56:12 Voltage Offset Correction: v_off_ini = 401.306 uV, v_off_fin = 396.670 uV 17:56:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.077 uVs 17:56:12 Integrated Voltage Measurement... 17:56:21 Voltage Offset Correction: v_off_ini = 397.347 uV, v_off_fin = 415.890 uV 17:56:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.780 uVs 17:56:23 I2X Average and RMS of Measurements VT = -105.826 +- 2.622 uVs I2X = 9.736 +- 0.241 uTm^2 17:56:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:56:28 Integrated Voltage Measurement... 17:56:37 Voltage Offset Correction: v_off_ini = 402.637 uV, v_off_fin = 397.024 uV 17:56:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.370 uVs 17:56:37 Integrated Voltage Measurement... 17:56:46 Voltage Offset Correction: v_off_ini = 399.164 uV, v_off_fin = 406.358 uV 17:56:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.879 uVs 17:56:46 Integrated Voltage Measurement... 17:56:55 Voltage Offset Correction: v_off_ini = 398.300 uV, v_off_fin = 399.019 uV 17:56:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.631 uVs 17:56:56 Integrated Voltage Measurement... 17:57:05 Voltage Offset Correction: v_off_ini = 398.828 uV, v_off_fin = 403.885 uV 17:57:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.911 uVs 17:57:05 Integrated Voltage Measurement... 17:57:14 Voltage Offset Correction: v_off_ini = 392.417 uV, v_off_fin = 398.367 uV 17:57:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.468 uVs 17:57:14 Integrated Voltage Measurement... 17:57:23 Voltage Offset Correction: v_off_ini = 398.195 uV, v_off_fin = 389.835 uV 17:57:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.581 uVs 17:57:25 I2Y Average and RMS of Measurements VT = -232.640 +- 2.928 uVs I2Y = -21.403 +- 0.269 uTm^2 17:57:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:57:46 Integrated Voltage Measurement... 17:57:55 Voltage Offset Correction: v_off_ini = 412.087 uV, v_off_fin = 412.664 uV 17:57:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -160.246 uVs 17:57:55 Integrated Voltage Measurement... 17:58:04 Voltage Offset Correction: v_off_ini = 414.218 uV, v_off_fin = 407.562 uV 17:58:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.523 uVs 17:58:04 Integrated Voltage Measurement... 17:58:13 Voltage Offset Correction: v_off_ini = 397.686 uV, v_off_fin = 400.911 uV 17:58:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.376 uVs 17:58:13 Integrated Voltage Measurement... 17:58:22 Voltage Offset Correction: v_off_ini = 402.644 uV, v_off_fin = 398.142 uV 17:58:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.910 uVs 17:58:22 Integrated Voltage Measurement... 17:58:31 Voltage Offset Correction: v_off_ini = 390.934 uV, v_off_fin = 396.320 uV 17:58:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.646 uVs 17:58:31 Integrated Voltage Measurement... 17:58:40 Voltage Offset Correction: v_off_ini = 398.892 uV, v_off_fin = 412.238 uV 17:58:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.126 uVs 17:58:45 I1X Average and RMS of Measurements VT = -145.638 +- 1.945 uVs I1X = 29.128 +- 0.390 uTm 17:58:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:58:51 Integrated Voltage Measurement... 17:59:00 Voltage Offset Correction: v_off_ini = 426.572 uV, v_off_fin = 413.910 uV 17:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.774 uVs 17:59:00 Integrated Voltage Measurement... 17:59:09 Voltage Offset Correction: v_off_ini = 414.066 uV, v_off_fin = 424.655 uV 17:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.607 uVs 17:59:09 Integrated Voltage Measurement... 17:59:18 Voltage Offset Correction: v_off_ini = 399.696 uV, v_off_fin = 384.330 uV 17:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.878 uVs 17:59:18 Integrated Voltage Measurement... 17:59:27 Voltage Offset Correction: v_off_ini = 408.792 uV, v_off_fin = 416.151 uV 17:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.912 uVs 17:59:27 Integrated Voltage Measurement... 17:59:36 Voltage Offset Correction: v_off_ini = 434.874 uV, v_off_fin = 421.583 uV 17:59:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.555 uVs 17:59:36 Integrated Voltage Measurement... 17:59:45 Voltage Offset Correction: v_off_ini = 425.194 uV, v_off_fin = 438.534 uV 17:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.351 uVs 17:59:50 I1Y Average and RMS of Measurements VT = -210.013 +- 4.689 uVs I1Y = -42.003 +- 0.938 uTm 17:59:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:59:57 Integrated Voltage Measurement... 18:00:06 Voltage Offset Correction: v_off_ini = 393.287 uV, v_off_fin = 401.904 uV 18:00:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.009 uVs 18:00:06 Integrated Voltage Measurement... 18:00:15 Voltage Offset Correction: v_off_ini = 424.287 uV, v_off_fin = 424.070 uV 18:00:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.315 uVs 18:00:16 Integrated Voltage Measurement... 18:00:24 Voltage Offset Correction: v_off_ini = 415.352 uV, v_off_fin = 415.747 uV 18:00:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.841 uVs 18:00:25 Integrated Voltage Measurement... 18:00:34 Voltage Offset Correction: v_off_ini = 429.327 uV, v_off_fin = 433.663 uV 18:00:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.076 uVs 18:00:34 Integrated Voltage Measurement... 18:00:43 Voltage Offset Correction: v_off_ini = 422.012 uV, v_off_fin = 410.769 uV 18:00:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.872 uVs 18:00:43 Integrated Voltage Measurement... 18:00:52 Voltage Offset Correction: v_off_ini = 415.440 uV, v_off_fin = 431.063 uV 18:00:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.576 uVs 18:00:54 I2X Average and RMS of Measurements VT = -135.615 +- 6.830 uVs I2X = 12.477 +- 0.628 uTm^2 18:00:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:01:02 Integrated Voltage Measurement... 18:01:11 Voltage Offset Correction: v_off_ini = 435.515 uV, v_off_fin = 419.065 uV 18:01:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.695 uVs 18:01:11 Integrated Voltage Measurement... 18:01:20 Voltage Offset Correction: v_off_ini = 423.258 uV, v_off_fin = 436.376 uV 18:01:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.837 uVs 18:01:20 Integrated Voltage Measurement... 18:01:29 Voltage Offset Correction: v_off_ini = 434.113 uV, v_off_fin = 438.371 uV 18:01:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.123 uVs 18:01:29 Integrated Voltage Measurement... 18:01:38 Voltage Offset Correction: v_off_ini = 421.442 uV, v_off_fin = 419.958 uV 18:01:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.021 uVs 18:01:38 Integrated Voltage Measurement... 18:01:47 Voltage Offset Correction: v_off_ini = 421.742 uV, v_off_fin = 423.348 uV 18:01:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.609 uVs 18:01:47 Integrated Voltage Measurement... 18:01:56 Voltage Offset Correction: v_off_ini = 421.872 uV, v_off_fin = 420.042 uV 18:01:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.457 uVs 18:01:58 I2Y Average and RMS of Measurements VT = -245.790 +- 3.720 uVs I2Y = -22.613 +- 0.342 uTm^2 18:02:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:02:07 Integrated Voltage Measurement... 18:02:16 Voltage Offset Correction: v_off_ini = 415.036 uV, v_off_fin = 424.699 uV 18:02:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.424 uVs 18:02:16 Integrated Voltage Measurement... 18:02:25 Voltage Offset Correction: v_off_ini = 425.838 uV, v_off_fin = 446.324 uV 18:02:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.342 uVs 18:02:25 Integrated Voltage Measurement... 18:02:34 Voltage Offset Correction: v_off_ini = 436.016 uV, v_off_fin = 426.761 uV 18:02:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.708 uVs 18:02:34 Integrated Voltage Measurement... 18:02:43 Voltage Offset Correction: v_off_ini = 420.137 uV, v_off_fin = 416.903 uV 18:02:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 131.647 uVs 18:02:43 Integrated Voltage Measurement... 18:02:52 Voltage Offset Correction: v_off_ini = 418.857 uV, v_off_fin = 437.571 uV 18:02:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.619 uVs 18:02:52 Integrated Voltage Measurement... 18:03:01 Voltage Offset Correction: v_off_ini = 438.366 uV, v_off_fin = 429.054 uV 18:03:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.228 uVs 18:03:06 I1X Average and RMS of Measurements VT = -130.661 +- 2.984 uVs I1X = 26.133 +- 0.597 uTm 18:03:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:03:12 Integrated Voltage Measurement... 18:03:21 Voltage Offset Correction: v_off_ini = 429.940 uV, v_off_fin = 407.503 uV 18:03:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.907 uVs 18:03:21 Integrated Voltage Measurement... 18:03:30 Voltage Offset Correction: v_off_ini = 416.767 uV, v_off_fin = 420.578 uV 18:03:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.219 uVs 18:03:30 Integrated Voltage Measurement... 18:03:39 Voltage Offset Correction: v_off_ini = 404.691 uV, v_off_fin = 399.030 uV 18:03:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.927 uVs 18:03:39 Integrated Voltage Measurement... 18:03:48 Voltage Offset Correction: v_off_ini = 419.183 uV, v_off_fin = 398.179 uV 18:03:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.936 uVs 18:03:48 Integrated Voltage Measurement... 18:03:57 Voltage Offset Correction: v_off_ini = 401.018 uV, v_off_fin = 373.497 uV 18:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.826 uVs 18:03:57 Integrated Voltage Measurement... 18:04:06 Voltage Offset Correction: v_off_ini = 389.305 uV, v_off_fin = 396.716 uV 18:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.640 uVs 18:04:11 I1Y Average and RMS of Measurements VT = -213.743 +- 9.836 uVs I1Y = -42.749 +- 1.967 uTm 18:04:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:04:18 Integrated Voltage Measurement... 18:04:27 Voltage Offset Correction: v_off_ini = 409.019 uV, v_off_fin = 392.924 uV 18:04:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.671 uVs 18:04:27 Integrated Voltage Measurement... 18:04:36 Voltage Offset Correction: v_off_ini = 394.438 uV, v_off_fin = 404.701 uV 18:04:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.786 uVs 18:04:36 Integrated Voltage Measurement... 18:04:45 Voltage Offset Correction: v_off_ini = 400.093 uV, v_off_fin = 397.610 uV 18:04:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.340 uVs 18:04:45 Integrated Voltage Measurement... 18:04:54 Voltage Offset Correction: v_off_ini = 401.117 uV, v_off_fin = 411.989 uV 18:04:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.352 uVs 18:04:54 Integrated Voltage Measurement... 18:05:03 Voltage Offset Correction: v_off_ini = 394.831 uV, v_off_fin = 397.558 uV 18:05:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.244 uVs 18:05:03 Integrated Voltage Measurement... 18:05:12 Voltage Offset Correction: v_off_ini = 408.788 uV, v_off_fin = 408.901 uV 18:05:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.186 uVs 18:05:15 I2X Average and RMS of Measurements VT = -127.930 +- 7.581 uVs I2X = 11.770 +- 0.697 uTm^2 18:05:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:05:23 Integrated Voltage Measurement... 18:05:32 Voltage Offset Correction: v_off_ini = 399.233 uV, v_off_fin = 389.289 uV 18:05:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.668 uVs 18:05:32 Integrated Voltage Measurement... 18:05:41 Voltage Offset Correction: v_off_ini = 378.685 uV, v_off_fin = 390.664 uV 18:05:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.276 uVs 18:05:41 Integrated Voltage Measurement... 18:05:50 Voltage Offset Correction: v_off_ini = 371.969 uV, v_off_fin = 388.360 uV 18:05:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.106 uVs 18:05:50 Integrated Voltage Measurement... 18:05:59 Voltage Offset Correction: v_off_ini = 381.179 uV, v_off_fin = 361.593 uV 18:05:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.247 uVs 18:05:59 Integrated Voltage Measurement... 18:06:08 Voltage Offset Correction: v_off_ini = 390.446 uV, v_off_fin = 387.394 uV 18:06:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.019 uVs 18:06:08 Integrated Voltage Measurement... 18:06:17 Voltage Offset Correction: v_off_ini = 387.024 uV, v_off_fin = 393.157 uV 18:06:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.876 uVs 18:06:19 I2Y Average and RMS of Measurements VT = -245.532 +- 2.878 uVs I2Y = -22.589 +- 0.265 uTm^2 18:06:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:28 Integrated Voltage Measurement... 18:06:37 Voltage Offset Correction: v_off_ini = 397.126 uV, v_off_fin = 382.279 uV 18:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.065 uVs 18:06:37 Integrated Voltage Measurement... 18:06:46 Voltage Offset Correction: v_off_ini = 382.928 uV, v_off_fin = 380.272 uV 18:06:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 99.620 uVs 18:06:46 Integrated Voltage Measurement... 18:06:55 Voltage Offset Correction: v_off_ini = 389.579 uV, v_off_fin = 392.141 uV 18:06:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.737 uVs 18:06:55 Integrated Voltage Measurement... 18:07:04 Voltage Offset Correction: v_off_ini = 401.529 uV, v_off_fin = 389.397 uV 18:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.714 uVs 18:07:04 Integrated Voltage Measurement... 18:07:13 Voltage Offset Correction: v_off_ini = 396.418 uV, v_off_fin = 383.598 uV 18:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.444 uVs 18:07:13 Integrated Voltage Measurement... 18:07:22 Voltage Offset Correction: v_off_ini = 386.036 uV, v_off_fin = 401.910 uV 18:07:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.570 uVs 18:07:26 I1X Average and RMS of Measurements VT = -113.358 +- 9.287 uVs I1X = 22.672 +- 1.858 uTm 18:07:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:33 Integrated Voltage Measurement... 18:07:42 Voltage Offset Correction: v_off_ini = 392.951 uV, v_off_fin = 386.397 uV 18:07:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.338 uVs 18:07:42 Integrated Voltage Measurement... 18:07:51 Voltage Offset Correction: v_off_ini = 379.246 uV, v_off_fin = 387.905 uV 18:07:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.387 uVs 18:07:51 Integrated Voltage Measurement... 18:08:00 Voltage Offset Correction: v_off_ini = 403.979 uV, v_off_fin = 380.630 uV 18:08:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.941 uVs 18:08:00 Integrated Voltage Measurement... 18:08:09 Voltage Offset Correction: v_off_ini = 375.136 uV, v_off_fin = 398.776 uV 18:08:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.527 uVs 18:08:09 Integrated Voltage Measurement... 18:08:18 Voltage Offset Correction: v_off_ini = 404.616 uV, v_off_fin = 396.509 uV 18:08:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.528 uVs 18:08:18 Integrated Voltage Measurement... 18:08:27 Voltage Offset Correction: v_off_ini = 401.875 uV, v_off_fin = 391.447 uV 18:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.191 uVs 18:08:31 I1Y Average and RMS of Measurements VT = -216.819 +- 10.237 uVs I1Y = -43.364 +- 2.047 uTm 18:08:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:08:39 Integrated Voltage Measurement... 18:08:48 Voltage Offset Correction: v_off_ini = 392.465 uV, v_off_fin = 377.083 uV 18:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.482 uVs 18:08:48 Integrated Voltage Measurement... 18:08:57 Voltage Offset Correction: v_off_ini = 384.848 uV, v_off_fin = 397.595 uV 18:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.276 uVs 18:08:57 Integrated Voltage Measurement... 18:09:06 Voltage Offset Correction: v_off_ini = 389.457 uV, v_off_fin = 384.239 uV 18:09:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.622 uVs 18:09:06 Integrated Voltage Measurement... 18:09:15 Voltage Offset Correction: v_off_ini = 383.593 uV, v_off_fin = 394.932 uV 18:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.103 uVs 18:09:15 Integrated Voltage Measurement... 18:09:24 Voltage Offset Correction: v_off_ini = 385.648 uV, v_off_fin = 372.276 uV 18:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.240 uVs 18:09:24 Integrated Voltage Measurement... 18:09:33 Voltage Offset Correction: v_off_ini = 374.562 uV, v_off_fin = 375.110 uV 18:09:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.552 uVs 18:09:36 I2X Average and RMS of Measurements VT = -119.879 +- 1.426 uVs I2X = 11.029 +- 0.131 uTm^2 18:09:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:09:44 Integrated Voltage Measurement... 18:09:53 Voltage Offset Correction: v_off_ini = 381.632 uV, v_off_fin = 385.171 uV 18:09:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.190 uVs 18:09:53 Integrated Voltage Measurement... 18:10:02 Voltage Offset Correction: v_off_ini = 384.108 uV, v_off_fin = 389.364 uV 18:10:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.876 uVs 18:10:02 Integrated Voltage Measurement... 18:10:11 Voltage Offset Correction: v_off_ini = 393.066 uV, v_off_fin = 387.487 uV 18:10:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.255 uVs 18:10:11 Integrated Voltage Measurement... 18:10:20 Voltage Offset Correction: v_off_ini = 390.550 uV, v_off_fin = 382.612 uV 18:10:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.577 uVs 18:10:20 Integrated Voltage Measurement... 18:10:29 Voltage Offset Correction: v_off_ini = 381.704 uV, v_off_fin = 395.498 uV 18:10:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.690 uVs 18:10:29 Integrated Voltage Measurement... 18:10:38 Voltage Offset Correction: v_off_ini = 361.171 uV, v_off_fin = 360.917 uV 18:10:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.346 uVs 18:10:40 I2Y Average and RMS of Measurements VT = -241.656 +- 9.280 uVs I2Y = -22.232 +- 0.854 uTm^2 18:10:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:10:49 Integrated Voltage Measurement... 18:10:58 Voltage Offset Correction: v_off_ini = 394.681 uV, v_off_fin = 389.970 uV 18:10:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -97.843 uVs 18:10:58 Integrated Voltage Measurement... 18:11:07 Voltage Offset Correction: v_off_ini = 399.236 uV, v_off_fin = 386.739 uV 18:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.079 uVs 18:11:07 Integrated Voltage Measurement... 18:11:16 Voltage Offset Correction: v_off_ini = 379.559 uV, v_off_fin = 389.257 uV 18:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.215 uVs 18:11:16 Integrated Voltage Measurement... 18:11:25 Voltage Offset Correction: v_off_ini = 388.934 uV, v_off_fin = 393.615 uV 18:11:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.174 uVs 18:11:25 Integrated Voltage Measurement... 18:11:34 Voltage Offset Correction: v_off_ini = 386.888 uV, v_off_fin = 380.877 uV 18:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.333 uVs 18:11:34 Integrated Voltage Measurement... 18:11:43 Voltage Offset Correction: v_off_ini = 384.051 uV, v_off_fin = 387.857 uV 18:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.976 uVs 18:11:48 I1X Average and RMS of Measurements VT = -108.103 +- 9.019 uVs I1X = 21.621 +- 1.803 uTm 18:11:50 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:11:54 Integrated Voltage Measurement... 18:12:03 Voltage Offset Correction: v_off_ini = 380.478 uV, v_off_fin = 367.196 uV 18:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.379 uVs 18:12:03 Integrated Voltage Measurement... 18:12:12 Voltage Offset Correction: v_off_ini = 374.125 uV, v_off_fin = 385.678 uV 18:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.875 uVs 18:12:12 Integrated Voltage Measurement... 18:12:21 Voltage Offset Correction: v_off_ini = 369.093 uV, v_off_fin = 370.902 uV 18:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.248 uVs 18:12:21 Integrated Voltage Measurement... 18:12:30 Voltage Offset Correction: v_off_ini = 385.927 uV, v_off_fin = 398.813 uV 18:12:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.595 uVs 18:12:30 Integrated Voltage Measurement... 18:12:39 Voltage Offset Correction: v_off_ini = 370.199 uV, v_off_fin = 369.765 uV 18:12:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.606 uVs 18:12:39 Integrated Voltage Measurement... 18:12:48 Voltage Offset Correction: v_off_ini = 357.979 uV, v_off_fin = 377.292 uV 18:12:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.295 uVs 18:12:53 I1Y Average and RMS of Measurements VT = -213.833 +- 9.327 uVs I1Y = -42.767 +- 1.865 uTm 18:12:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:13:00 Integrated Voltage Measurement... 18:13:09 Voltage Offset Correction: v_off_ini = 344.715 uV, v_off_fin = 339.861 uV 18:13:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.848 uVs 18:13:09 Integrated Voltage Measurement... 18:13:18 Voltage Offset Correction: v_off_ini = 350.622 uV, v_off_fin = 352.969 uV 18:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.107 uVs 18:13:18 Integrated Voltage Measurement... 18:13:27 Voltage Offset Correction: v_off_ini = 348.492 uV, v_off_fin = 349.051 uV 18:13:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.643 uVs 18:13:27 Integrated Voltage Measurement... 18:13:36 Voltage Offset Correction: v_off_ini = 361.010 uV, v_off_fin = 367.204 uV 18:13:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.567 uVs 18:13:36 Integrated Voltage Measurement... 18:13:45 Voltage Offset Correction: v_off_ini = 353.467 uV, v_off_fin = 341.888 uV 18:13:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.115 uVs 18:13:45 Integrated Voltage Measurement... 18:13:54 Voltage Offset Correction: v_off_ini = 357.014 uV, v_off_fin = 364.334 uV 18:13:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.303 uVs 18:13:57 I2X Average and RMS of Measurements VT = -104.930 +- 8.668 uVs I2X = 9.654 +- 0.797 uTm^2 18:14:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:14:05 Integrated Voltage Measurement... 18:14:14 Voltage Offset Correction: v_off_ini = 357.833 uV, v_off_fin = 351.348 uV 18:14:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.261 uVs 18:14:14 Integrated Voltage Measurement... 18:14:23 Voltage Offset Correction: v_off_ini = 351.661 uV, v_off_fin = 345.872 uV 18:14:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.922 uVs 18:14:23 Integrated Voltage Measurement... 18:14:32 Voltage Offset Correction: v_off_ini = 352.770 uV, v_off_fin = 353.170 uV 18:14:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.938 uVs 18:14:32 Integrated Voltage Measurement... 18:14:41 Voltage Offset Correction: v_off_ini = 347.350 uV, v_off_fin = 347.394 uV 18:14:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.549 uVs 18:14:41 Integrated Voltage Measurement... 18:14:50 Voltage Offset Correction: v_off_ini = 359.380 uV, v_off_fin = 355.832 uV 18:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.074 uVs 18:14:50 Integrated Voltage Measurement... 18:14:59 Voltage Offset Correction: v_off_ini = 362.038 uV, v_off_fin = 357.033 uV 18:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.031 uVs 18:15:01 I2Y Average and RMS of Measurements VT = -248.129 +- 4.421 uVs I2Y = -22.828 +- 0.407 uTm^2 18:15:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:15:10 Integrated Voltage Measurement... 18:15:19 Voltage Offset Correction: v_off_ini = 356.326 uV, v_off_fin = 357.225 uV 18:15:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.304 uVs 18:15:19 Integrated Voltage Measurement... 18:15:28 Voltage Offset Correction: v_off_ini = 341.338 uV, v_off_fin = 358.321 uV 18:15:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.517 uVs 18:15:28 Integrated Voltage Measurement... 18:15:37 Voltage Offset Correction: v_off_ini = 372.868 uV, v_off_fin = 359.273 uV 18:15:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.819 uVs 18:15:37 Integrated Voltage Measurement... 18:15:46 Voltage Offset Correction: v_off_ini = 338.630 uV, v_off_fin = 348.227 uV 18:15:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.783 uVs 18:15:46 Integrated Voltage Measurement... 18:15:55 Voltage Offset Correction: v_off_ini = 354.802 uV, v_off_fin = 361.369 uV 18:15:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.864 uVs 18:15:55 Integrated Voltage Measurement... 18:16:04 Voltage Offset Correction: v_off_ini = 349.155 uV, v_off_fin = 347.703 uV 18:16:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.905 uVs 18:16:08 I1X Average and RMS of Measurements VT = -103.699 +- 9.158 uVs I1X = 20.740 +- 1.832 uTm 18:16:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:16:15 Integrated Voltage Measurement... 18:16:24 Voltage Offset Correction: v_off_ini = 360.133 uV, v_off_fin = 358.737 uV 18:16:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.621 uVs 18:16:24 Integrated Voltage Measurement... 18:16:33 Voltage Offset Correction: v_off_ini = 361.053 uV, v_off_fin = 371.738 uV 18:16:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.209 uVs 18:16:33 Integrated Voltage Measurement... 18:16:42 Voltage Offset Correction: v_off_ini = 359.893 uV, v_off_fin = 343.791 uV 18:16:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -202.626 uVs 18:16:42 Integrated Voltage Measurement... 18:16:51 Voltage Offset Correction: v_off_ini = 353.753 uV, v_off_fin = 375.595 uV 18:16:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.206 uVs 18:16:51 Integrated Voltage Measurement... 18:17:00 Voltage Offset Correction: v_off_ini = 365.162 uV, v_off_fin = 354.686 uV 18:17:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -229.538 uVs 18:17:00 Integrated Voltage Measurement... 18:17:09 Voltage Offset Correction: v_off_ini = 352.488 uV, v_off_fin = 374.930 uV 18:17:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.600 uVs 18:17:13 I1Y Average and RMS of Measurements VT = -216.967 +- 6.916 uVs I1Y = -43.395 +- 1.383 uTm 18:17:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:17:21 Integrated Voltage Measurement... 18:17:30 Voltage Offset Correction: v_off_ini = 360.546 uV, v_off_fin = 354.191 uV 18:17:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.715 uVs 18:17:30 Integrated Voltage Measurement... 18:17:39 Voltage Offset Correction: v_off_ini = 382.799 uV, v_off_fin = 387.073 uV 18:17:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.831 uVs 18:17:39 Integrated Voltage Measurement... 18:17:48 Voltage Offset Correction: v_off_ini = 375.368 uV, v_off_fin = 369.094 uV 18:17:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.390 uVs 18:17:48 Integrated Voltage Measurement... 18:17:57 Voltage Offset Correction: v_off_ini = 375.703 uV, v_off_fin = 387.203 uV 18:17:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.052 uVs 18:17:57 Integrated Voltage Measurement... 18:18:06 Voltage Offset Correction: v_off_ini = 369.572 uV, v_off_fin = 365.148 uV 18:18:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.430 uVs 18:18:06 Integrated Voltage Measurement... 18:18:15 Voltage Offset Correction: v_off_ini = 375.636 uV, v_off_fin = 383.520 uV 18:18:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.916 uVs 18:18:18 I2X Average and RMS of Measurements VT = -96.555 +- 5.244 uVs I2X = 8.883 +- 0.482 uTm^2 18:18:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:18:25 Integrated Voltage Measurement... 18:18:34 Voltage Offset Correction: v_off_ini = 376.469 uV, v_off_fin = 355.989 uV 18:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.205 uVs 18:18:34 Integrated Voltage Measurement... 18:18:43 Voltage Offset Correction: v_off_ini = 394.134 uV, v_off_fin = 386.760 uV 18:18:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.093 uVs 18:18:43 Integrated Voltage Measurement... 18:18:52 Voltage Offset Correction: v_off_ini = 387.602 uV, v_off_fin = 396.293 uV 18:18:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.078 uVs 18:18:52 Integrated Voltage Measurement... 18:19:01 Voltage Offset Correction: v_off_ini = 398.678 uV, v_off_fin = 387.927 uV 18:19:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.881 uVs 18:19:01 Integrated Voltage Measurement... 18:19:10 Voltage Offset Correction: v_off_ini = 384.317 uV, v_off_fin = 370.870 uV 18:19:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.307 uVs 18:19:10 Integrated Voltage Measurement... 18:19:19 Voltage Offset Correction: v_off_ini = 372.952 uV, v_off_fin = 369.812 uV 18:19:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.393 uVs 18:19:22 I2Y Average and RMS of Measurements VT = -256.993 +- 2.555 uVs I2Y = -23.643 +- 0.235 uTm^2 18:19:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:19:34 Integrated Voltage Measurement... 18:19:43 Voltage Offset Correction: v_off_ini = 361.919 uV, v_off_fin = 352.779 uV 18:19:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.960 uVs 18:19:43 Integrated Voltage Measurement... 18:19:52 Voltage Offset Correction: v_off_ini = 359.192 uV, v_off_fin = 366.915 uV 18:19:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.029 uVs 18:19:52 Integrated Voltage Measurement... 18:20:01 Voltage Offset Correction: v_off_ini = 366.885 uV, v_off_fin = 358.926 uV 18:20:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.394 uVs 18:20:01 Integrated Voltage Measurement... 18:20:10 Voltage Offset Correction: v_off_ini = 364.253 uV, v_off_fin = 359.708 uV 18:20:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.903 uVs 18:20:10 Integrated Voltage Measurement... 18:20:19 Voltage Offset Correction: v_off_ini = 358.116 uV, v_off_fin = 351.847 uV 18:20:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.955 uVs 18:20:19 Integrated Voltage Measurement... 18:20:28 Voltage Offset Correction: v_off_ini = 356.502 uV, v_off_fin = 352.160 uV 18:20:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.943 uVs 18:20:32 I1X Average and RMS of Measurements VT = -116.697 +- 8.504 uVs I1X = 23.340 +- 1.700 uTm 18:20:34 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:20:39 Integrated Voltage Measurement... 18:20:48 Voltage Offset Correction: v_off_ini = 363.874 uV, v_off_fin = 351.934 uV 18:20:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -231.073 uVs 18:20:48 Integrated Voltage Measurement... 18:20:57 Voltage Offset Correction: v_off_ini = 362.899 uV, v_off_fin = 372.136 uV 18:20:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.499 uVs 18:20:57 Integrated Voltage Measurement... 18:21:06 Voltage Offset Correction: v_off_ini = 351.716 uV, v_off_fin = 340.250 uV 18:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.947 uVs 18:21:06 Integrated Voltage Measurement... 18:21:15 Voltage Offset Correction: v_off_ini = 351.265 uV, v_off_fin = 361.196 uV 18:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.598 uVs 18:21:15 Integrated Voltage Measurement... 18:21:24 Voltage Offset Correction: v_off_ini = 352.325 uV, v_off_fin = 327.462 uV 18:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.187 uVs 18:21:24 Integrated Voltage Measurement... 18:21:33 Voltage Offset Correction: v_off_ini = 345.841 uV, v_off_fin = 354.950 uV 18:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.235 uVs 18:21:37 I1Y Average and RMS of Measurements VT = -214.090 +- 10.850 uVs I1Y = -42.819 +- 2.171 uTm 18:21:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:21:42 Integrated Voltage Measurement... 18:21:51 Voltage Offset Correction: v_off_ini = 341.522 uV, v_off_fin = 349.062 uV 18:21:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.327 uVs 18:21:51 Integrated Voltage Measurement... 18:22:00 Voltage Offset Correction: v_off_ini = 362.011 uV, v_off_fin = 369.331 uV 18:22:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.759 uVs 18:22:00 Integrated Voltage Measurement... 18:22:09 Voltage Offset Correction: v_off_ini = 344.332 uV, v_off_fin = 346.749 uV 18:22:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.866 uVs 18:22:09 Integrated Voltage Measurement... 18:22:18 Voltage Offset Correction: v_off_ini = 348.365 uV, v_off_fin = 347.559 uV 18:22:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.897 uVs 18:22:18 Integrated Voltage Measurement... 18:22:27 Voltage Offset Correction: v_off_ini = 351.036 uV, v_off_fin = 336.968 uV 18:22:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.237 uVs 18:22:27 Integrated Voltage Measurement... 18:22:36 Voltage Offset Correction: v_off_ini = 354.266 uV, v_off_fin = 347.155 uV 18:22:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.473 uVs 18:22:38 I2X Average and RMS of Measurements VT = -119.260 +- 1.358 uVs I2X = 10.972 +- 0.125 uTm^2 18:22:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:22:44 Integrated Voltage Measurement... 18:22:52 Voltage Offset Correction: v_off_ini = 350.634 uV, v_off_fin = 340.922 uV 18:22:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.607 uVs 18:22:53 Integrated Voltage Measurement... 18:23:01 Voltage Offset Correction: v_off_ini = 352.955 uV, v_off_fin = 362.677 uV 18:23:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.722 uVs 18:23:02 Integrated Voltage Measurement... 18:23:11 Voltage Offset Correction: v_off_ini = 359.580 uV, v_off_fin = 358.758 uV 18:23:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.055 uVs 18:23:11 Integrated Voltage Measurement... 18:23:20 Voltage Offset Correction: v_off_ini = 359.546 uV, v_off_fin = 346.815 uV 18:23:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.338 uVs 18:23:20 Integrated Voltage Measurement... 18:23:29 Voltage Offset Correction: v_off_ini = 364.158 uV, v_off_fin = 358.508 uV 18:23:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.456 uVs 18:23:29 Integrated Voltage Measurement... 18:23:38 Voltage Offset Correction: v_off_ini = 340.284 uV, v_off_fin = 351.627 uV 18:23:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.370 uVs 18:23:40 I2Y Average and RMS of Measurements VT = -250.925 +- 1.248 uVs I2Y = -23.085 +- 0.115 uTm^2 18:23:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:23:48 Integrated Voltage Measurement... 18:23:57 Voltage Offset Correction: v_off_ini = 334.725 uV, v_off_fin = 327.813 uV 18:23:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.212 uVs 18:23:57 Integrated Voltage Measurement... 18:24:06 Voltage Offset Correction: v_off_ini = 327.977 uV, v_off_fin = 348.894 uV 18:24:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 143.718 uVs 18:24:06 Integrated Voltage Measurement... 18:24:15 Voltage Offset Correction: v_off_ini = 338.631 uV, v_off_fin = 339.643 uV 18:24:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.834 uVs 18:24:15 Integrated Voltage Measurement... 18:24:24 Voltage Offset Correction: v_off_ini = 343.345 uV, v_off_fin = 341.201 uV 18:24:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.661 uVs 18:24:24 Integrated Voltage Measurement... 18:24:33 Voltage Offset Correction: v_off_ini = 338.102 uV, v_off_fin = 333.517 uV 18:24:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.772 uVs 18:24:33 Integrated Voltage Measurement... 18:24:42 Voltage Offset Correction: v_off_ini = 333.786 uV, v_off_fin = 339.878 uV 18:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.566 uVs 18:24:47 I1X Average and RMS of Measurements VT = -119.960 +- 14.959 uVs I1X = 23.993 +- 2.992 uTm 18:24:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:24:53 Integrated Voltage Measurement... 18:25:02 Voltage Offset Correction: v_off_ini = 332.058 uV, v_off_fin = 321.256 uV 18:25:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.008 uVs 18:25:02 Integrated Voltage Measurement... 18:25:11 Voltage Offset Correction: v_off_ini = 318.131 uV, v_off_fin = 344.771 uV 18:25:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.803 uVs 18:25:11 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 340.710 uV, v_off_fin = 340.392 uV 18:25:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.626 uVs 18:25:20 Integrated Voltage Measurement... 18:25:29 Voltage Offset Correction: v_off_ini = 346.666 uV, v_off_fin = 352.012 uV 18:25:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.667 uVs 18:25:29 Integrated Voltage Measurement... 18:25:38 Voltage Offset Correction: v_off_ini = 339.042 uV, v_off_fin = 323.864 uV 18:25:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.165 uVs 18:25:38 Integrated Voltage Measurement... 18:25:47 Voltage Offset Correction: v_off_ini = 343.941 uV, v_off_fin = 344.431 uV 18:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.634 uVs 18:25:51 I1Y Average and RMS of Measurements VT = -217.984 +- 5.817 uVs I1Y = -43.597 +- 1.163 uTm 18:25:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:25:57 Integrated Voltage Measurement... 18:26:06 Voltage Offset Correction: v_off_ini = 340.353 uV, v_off_fin = 338.248 uV 18:26:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.295 uVs 18:26:06 Integrated Voltage Measurement... 18:26:15 Voltage Offset Correction: v_off_ini = 340.674 uV, v_off_fin = 365.750 uV 18:26:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.684 uVs 18:26:15 Integrated Voltage Measurement... 18:26:24 Voltage Offset Correction: v_off_ini = 349.052 uV, v_off_fin = 354.720 uV 18:26:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.133 uVs 18:26:24 Integrated Voltage Measurement... 18:26:33 Voltage Offset Correction: v_off_ini = 353.497 uV, v_off_fin = 351.490 uV 18:26:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.848 uVs 18:26:33 Integrated Voltage Measurement... 18:26:42 Voltage Offset Correction: v_off_ini = 339.722 uV, v_off_fin = 331.754 uV 18:26:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.340 uVs 18:26:42 Integrated Voltage Measurement... 18:26:51 Voltage Offset Correction: v_off_ini = 341.947 uV, v_off_fin = 355.259 uV 18:26:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.464 uVs 18:26:53 I2X Average and RMS of Measurements VT = -120.961 +- 12.084 uVs I2X = 11.128 +- 1.112 uTm^2 18:26:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:26:58 Integrated Voltage Measurement... 18:27:07 Voltage Offset Correction: v_off_ini = 350.785 uV, v_off_fin = 348.275 uV 18:27:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.560 uVs 18:27:07 Integrated Voltage Measurement... 18:27:16 Voltage Offset Correction: v_off_ini = 337.421 uV, v_off_fin = 354.380 uV 18:27:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.743 uVs 18:27:16 Integrated Voltage Measurement... 18:27:25 Voltage Offset Correction: v_off_ini = 354.324 uV, v_off_fin = 332.965 uV 18:27:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.999 uVs 18:27:25 Integrated Voltage Measurement... 18:27:34 Voltage Offset Correction: v_off_ini = 338.110 uV, v_off_fin = 349.849 uV 18:27:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.506 uVs 18:27:34 Integrated Voltage Measurement... 18:27:43 Voltage Offset Correction: v_off_ini = 351.985 uV, v_off_fin = 356.564 uV 18:27:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.648 uVs 18:27:43 Integrated Voltage Measurement... 18:27:52 Voltage Offset Correction: v_off_ini = 372.827 uV, v_off_fin = 379.079 uV 18:27:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.383 uVs 18:27:55 I2Y Average and RMS of Measurements VT = -245.973 +- 6.317 uVs I2Y = -22.630 +- 0.581 uTm^2 18:27:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:28:03 Integrated Voltage Measurement... 18:28:12 Voltage Offset Correction: v_off_ini = 340.640 uV, v_off_fin = 341.250 uV 18:28:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.021 uVs 18:28:12 Integrated Voltage Measurement... 18:28:21 Voltage Offset Correction: v_off_ini = 355.044 uV, v_off_fin = 360.420 uV 18:28:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.724 uVs 18:28:21 Integrated Voltage Measurement... 18:28:30 Voltage Offset Correction: v_off_ini = 347.323 uV, v_off_fin = 366.512 uV 18:28:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.415 uVs 18:28:30 Integrated Voltage Measurement... 18:28:39 Voltage Offset Correction: v_off_ini = 353.825 uV, v_off_fin = 350.658 uV 18:28:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.177 uVs 18:28:39 Integrated Voltage Measurement... 18:28:48 Voltage Offset Correction: v_off_ini = 357.986 uV, v_off_fin = 335.055 uV 18:28:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.333 uVs 18:28:48 Integrated Voltage Measurement... 18:28:57 Voltage Offset Correction: v_off_ini = 347.870 uV, v_off_fin = 352.144 uV 18:28:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.054 uVs 18:29:01 I1X Average and RMS of Measurements VT = -116.288 +- 8.510 uVs I1X = 23.258 +- 1.702 uTm 18:29:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:29:08 Integrated Voltage Measurement... 18:29:17 Voltage Offset Correction: v_off_ini = 348.640 uV, v_off_fin = 347.452 uV 18:29:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.192 uVs 18:29:17 Integrated Voltage Measurement... 18:29:26 Voltage Offset Correction: v_off_ini = 355.670 uV, v_off_fin = 342.954 uV 18:29:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.825 uVs 18:29:26 Integrated Voltage Measurement... 18:29:35 Voltage Offset Correction: v_off_ini = 357.842 uV, v_off_fin = 351.269 uV 18:29:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.585 uVs 18:29:35 Integrated Voltage Measurement... 18:29:44 Voltage Offset Correction: v_off_ini = 357.396 uV, v_off_fin = 362.774 uV 18:29:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.226 uVs 18:29:44 Integrated Voltage Measurement... 18:29:53 Voltage Offset Correction: v_off_ini = 345.224 uV, v_off_fin = 332.522 uV 18:29:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.792 uVs 18:29:53 Integrated Voltage Measurement... 18:30:02 Voltage Offset Correction: v_off_ini = 349.872 uV, v_off_fin = 352.901 uV 18:30:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.787 uVs 18:30:06 I1Y Average and RMS of Measurements VT = -208.401 +- 6.103 uVs I1Y = -41.680 +- 1.221 uTm 18:30:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:30:11 Integrated Voltage Measurement... 18:30:20 Voltage Offset Correction: v_off_ini = 361.273 uV, v_off_fin = 362.217 uV 18:30:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.815 uVs 18:30:20 Integrated Voltage Measurement... 18:30:29 Voltage Offset Correction: v_off_ini = 348.621 uV, v_off_fin = 371.229 uV 18:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.150 uVs 18:30:29 Integrated Voltage Measurement... 18:30:38 Voltage Offset Correction: v_off_ini = 365.377 uV, v_off_fin = 349.819 uV 18:30:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.607 uVs 18:30:38 Integrated Voltage Measurement... 18:30:47 Voltage Offset Correction: v_off_ini = 326.000 uV, v_off_fin = 333.451 uV 18:30:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.277 uVs 18:30:47 Integrated Voltage Measurement... 18:30:56 Voltage Offset Correction: v_off_ini = 331.660 uV, v_off_fin = 325.405 uV 18:30:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.924 uVs 18:30:56 Integrated Voltage Measurement... 18:31:05 Voltage Offset Correction: v_off_ini = 347.510 uV, v_off_fin = 348.120 uV 18:31:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.180 uVs 18:31:08 I2X Average and RMS of Measurements VT = -117.492 +- 4.986 uVs I2X = 10.809 +- 0.459 uTm^2 18:31:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:31:13 Integrated Voltage Measurement... 18:31:22 Voltage Offset Correction: v_off_ini = 340.685 uV, v_off_fin = 349.437 uV 18:31:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.389 uVs 18:31:22 Integrated Voltage Measurement... 18:31:31 Voltage Offset Correction: v_off_ini = 334.275 uV, v_off_fin = 338.099 uV 18:31:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.946 uVs 18:31:31 Integrated Voltage Measurement... 18:31:40 Voltage Offset Correction: v_off_ini = 338.914 uV, v_off_fin = 343.056 uV 18:31:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.546 uVs 18:31:40 Integrated Voltage Measurement... 18:31:49 Voltage Offset Correction: v_off_ini = 337.604 uV, v_off_fin = 347.754 uV 18:31:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.867 uVs 18:31:49 Integrated Voltage Measurement... 18:31:58 Voltage Offset Correction: v_off_ini = 336.818 uV, v_off_fin = 332.999 uV 18:31:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.349 uVs 18:31:58 Integrated Voltage Measurement... 18:32:07 Voltage Offset Correction: v_off_ini = 331.864 uV, v_off_fin = 344.964 uV 18:32:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.996 uVs 18:32:09 I2Y Average and RMS of Measurements VT = -245.682 +- 3.518 uVs I2Y = -22.603 +- 0.324 uTm^2 18:32:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:32:18 Integrated Voltage Measurement... 18:32:27 Voltage Offset Correction: v_off_ini = 342.099 uV, v_off_fin = 333.674 uV 18:32:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -110.870 uVs 18:32:27 Integrated Voltage Measurement... 18:32:36 Voltage Offset Correction: v_off_ini = 344.867 uV, v_off_fin = 344.983 uV 18:32:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.270 uVs 18:32:36 Integrated Voltage Measurement... 18:32:45 Voltage Offset Correction: v_off_ini = 344.461 uV, v_off_fin = 329.172 uV 18:32:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.581 uVs 18:32:45 Integrated Voltage Measurement... 18:32:54 Voltage Offset Correction: v_off_ini = 338.757 uV, v_off_fin = 333.786 uV 18:32:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.319 uVs 18:32:54 Integrated Voltage Measurement... 18:33:03 Voltage Offset Correction: v_off_ini = 335.035 uV, v_off_fin = 334.106 uV 18:33:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.976 uVs 18:33:03 Integrated Voltage Measurement... 18:33:12 Voltage Offset Correction: v_off_ini = 347.590 uV, v_off_fin = 355.280 uV 18:33:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.953 uVs 18:33:16 I1X Average and RMS of Measurements VT = -120.328 +- 8.053 uVs I1X = 24.068 +- 1.609 uTm 18:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:33:23 Integrated Voltage Measurement... 18:33:32 Voltage Offset Correction: v_off_ini = 363.858 uV, v_off_fin = 356.115 uV 18:33:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.523 uVs 18:33:32 Integrated Voltage Measurement... 18:33:41 Voltage Offset Correction: v_off_ini = 363.374 uV, v_off_fin = 369.624 uV 18:33:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.460 uVs 18:33:41 Integrated Voltage Measurement... 18:33:50 Voltage Offset Correction: v_off_ini = 363.898 uV, v_off_fin = 355.896 uV 18:33:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.766 uVs 18:33:50 Integrated Voltage Measurement... 18:33:59 Voltage Offset Correction: v_off_ini = 367.423 uV, v_off_fin = 374.650 uV 18:33:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.027 uVs 18:33:59 Integrated Voltage Measurement... 18:34:08 Voltage Offset Correction: v_off_ini = 356.147 uV, v_off_fin = 338.694 uV 18:34:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.065 uVs 18:34:08 Integrated Voltage Measurement... 18:34:17 Voltage Offset Correction: v_off_ini = 348.669 uV, v_off_fin = 373.398 uV 18:34:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.659 uVs 18:34:21 I1Y Average and RMS of Measurements VT = -206.417 +- 2.191 uVs I1Y = -41.281 +- 0.439 uTm 18:34:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:34:26 Integrated Voltage Measurement... 18:34:35 Voltage Offset Correction: v_off_ini = 357.329 uV, v_off_fin = 357.129 uV 18:34:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.630 uVs 18:34:35 Integrated Voltage Measurement... 18:34:44 Voltage Offset Correction: v_off_ini = 362.032 uV, v_off_fin = 376.010 uV 18:34:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.974 uVs 18:34:44 Integrated Voltage Measurement... 18:34:53 Voltage Offset Correction: v_off_ini = 375.245 uV, v_off_fin = 359.507 uV 18:34:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.016 uVs 18:34:53 Integrated Voltage Measurement... 18:35:02 Voltage Offset Correction: v_off_ini = 378.856 uV, v_off_fin = 365.190 uV 18:35:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.807 uVs 18:35:02 Integrated Voltage Measurement... 18:35:11 Voltage Offset Correction: v_off_ini = 360.897 uV, v_off_fin = 342.645 uV 18:35:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.328 uVs 18:35:11 Integrated Voltage Measurement... 18:35:20 Voltage Offset Correction: v_off_ini = 365.885 uV, v_off_fin = 366.316 uV 18:35:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.252 uVs 18:35:22 I2X Average and RMS of Measurements VT = -115.501 +- 1.918 uVs I2X = 10.626 +- 0.176 uTm^2 18:35:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:35:28 Integrated Voltage Measurement... 18:35:37 Voltage Offset Correction: v_off_ini = 355.082 uV, v_off_fin = 344.561 uV 18:35:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.262 uVs 18:35:37 Integrated Voltage Measurement... 18:35:46 Voltage Offset Correction: v_off_ini = 341.743 uV, v_off_fin = 353.795 uV 18:35:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.409 uVs 18:35:46 Integrated Voltage Measurement... 18:35:55 Voltage Offset Correction: v_off_ini = 356.422 uV, v_off_fin = 354.430 uV 18:35:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.829 uVs 18:35:55 Integrated Voltage Measurement... 18:36:04 Voltage Offset Correction: v_off_ini = 356.238 uV, v_off_fin = 357.312 uV 18:36:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.312 uVs 18:36:04 Integrated Voltage Measurement... 18:36:13 Voltage Offset Correction: v_off_ini = 350.197 uV, v_off_fin = 343.256 uV 18:36:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.803 uVs 18:36:13 Integrated Voltage Measurement... 18:36:22 Voltage Offset Correction: v_off_ini = 360.885 uV, v_off_fin = 357.605 uV 18:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.030 uVs 18:36:24 I2Y Average and RMS of Measurements VT = -242.108 +- 11.238 uVs I2Y = -22.274 +- 1.034 uTm^2 18:36:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:36:32 Integrated Voltage Measurement... 18:36:41 Voltage Offset Correction: v_off_ini = 356.298 uV, v_off_fin = 356.063 uV 18:36:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.108 uVs 18:36:41 Integrated Voltage Measurement... 18:36:50 Voltage Offset Correction: v_off_ini = 351.799 uV, v_off_fin = 355.362 uV 18:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.976 uVs 18:36:50 Integrated Voltage Measurement... 18:36:59 Voltage Offset Correction: v_off_ini = 339.542 uV, v_off_fin = 348.454 uV 18:36:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.745 uVs 18:36:59 Integrated Voltage Measurement... 18:37:08 Voltage Offset Correction: v_off_ini = 355.095 uV, v_off_fin = 363.390 uV 18:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.024 uVs 18:37:08 Integrated Voltage Measurement... 18:37:17 Voltage Offset Correction: v_off_ini = 349.962 uV, v_off_fin = 339.187 uV 18:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.830 uVs 18:37:17 Integrated Voltage Measurement... 18:37:26 Voltage Offset Correction: v_off_ini = 350.187 uV, v_off_fin = 368.727 uV 18:37:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.474 uVs 18:37:31 I1X Average and RMS of Measurements VT = -105.693 +- 2.037 uVs I1X = 21.139 +- 0.407 uTm 18:37:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:37:37 Integrated Voltage Measurement... 18:37:46 Voltage Offset Correction: v_off_ini = 347.901 uV, v_off_fin = 346.650 uV 18:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.626 uVs 18:37:46 Integrated Voltage Measurement... 18:37:55 Voltage Offset Correction: v_off_ini = 340.412 uV, v_off_fin = 352.748 uV 18:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.091 uVs 18:37:55 Integrated Voltage Measurement... 18:38:04 Voltage Offset Correction: v_off_ini = 346.656 uV, v_off_fin = 336.786 uV 18:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.542 uVs 18:38:04 Integrated Voltage Measurement... 18:38:13 Voltage Offset Correction: v_off_ini = 332.921 uV, v_off_fin = 358.554 uV 18:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.661 uVs 18:38:13 Integrated Voltage Measurement... 18:38:22 Voltage Offset Correction: v_off_ini = 336.650 uV, v_off_fin = 334.618 uV 18:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.648 uVs 18:38:22 Integrated Voltage Measurement... 18:38:31 Voltage Offset Correction: v_off_ini = 342.772 uV, v_off_fin = 347.866 uV 18:38:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.964 uVs 18:38:35 I1Y Average and RMS of Measurements VT = -202.089 +- 5.840 uVs I1Y = -40.414 +- 1.168 uTm 18:38:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:38:40 Integrated Voltage Measurement... 18:38:49 Voltage Offset Correction: v_off_ini = 352.511 uV, v_off_fin = 349.038 uV 18:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.006 uVs 18:38:49 Integrated Voltage Measurement... 18:38:58 Voltage Offset Correction: v_off_ini = 327.108 uV, v_off_fin = 353.159 uV 18:38:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.599 uVs 18:38:58 Integrated Voltage Measurement... 18:39:07 Voltage Offset Correction: v_off_ini = 338.221 uV, v_off_fin = 335.958 uV 18:39:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.576 uVs 18:39:07 Integrated Voltage Measurement... 18:39:16 Voltage Offset Correction: v_off_ini = 329.546 uV, v_off_fin = 346.683 uV 18:39:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.831 uVs 18:39:16 Integrated Voltage Measurement... 18:39:25 Voltage Offset Correction: v_off_ini = 339.270 uV, v_off_fin = 331.590 uV 18:39:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.039 uVs 18:39:25 Integrated Voltage Measurement... 18:39:34 Voltage Offset Correction: v_off_ini = 372.930 uV, v_off_fin = 364.935 uV 18:39:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.557 uVs 18:39:37 I2X Average and RMS of Measurements VT = -111.935 +- 5.432 uVs I2X = 10.298 +- 0.500 uTm^2 18:39:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:39:42 Integrated Voltage Measurement... 18:39:51 Voltage Offset Correction: v_off_ini = 357.457 uV, v_off_fin = 356.619 uV 18:39:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.434 uVs 18:39:51 Integrated Voltage Measurement... 18:40:00 Voltage Offset Correction: v_off_ini = 369.820 uV, v_off_fin = 376.241 uV 18:40:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 205.912 uVs 18:40:00 Integrated Voltage Measurement... 18:40:09 Voltage Offset Correction: v_off_ini = 382.354 uV, v_off_fin = 368.006 uV 18:40:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.701 uVs 18:40:09 Integrated Voltage Measurement... 18:40:18 Voltage Offset Correction: v_off_ini = 357.485 uV, v_off_fin = 367.297 uV 18:40:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.321 uVs 18:40:18 Integrated Voltage Measurement... 18:40:27 Voltage Offset Correction: v_off_ini = 361.984 uV, v_off_fin = 368.596 uV 18:40:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -215.761 uVs 18:40:27 Integrated Voltage Measurement... 18:40:36 Voltage Offset Correction: v_off_ini = 349.801 uV, v_off_fin = 358.814 uV 18:40:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 219.071 uVs 18:40:38 I2Y Average and RMS of Measurements VT = -227.366 +- 12.850 uVs I2Y = -20.919 +- 1.181 uTm^2 18:40:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:41:00 Integrated Voltage Measurement... 18:41:08 Voltage Offset Correction: v_off_ini = 354.250 uV, v_off_fin = 362.123 uV 18:41:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.344 uVs 18:41:09 Integrated Voltage Measurement... 18:41:17 Voltage Offset Correction: v_off_ini = 363.634 uV, v_off_fin = 353.962 uV 18:41:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.797 uVs 18:41:18 Integrated Voltage Measurement... 18:41:26 Voltage Offset Correction: v_off_ini = 349.278 uV, v_off_fin = 347.269 uV 18:41:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -148.944 uVs 18:41:27 Integrated Voltage Measurement... 18:41:35 Voltage Offset Correction: v_off_ini = 342.225 uV, v_off_fin = 364.368 uV 18:41:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.203 uVs 18:41:36 Integrated Voltage Measurement... 18:41:44 Voltage Offset Correction: v_off_ini = 346.975 uV, v_off_fin = 342.082 uV 18:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.723 uVs 18:41:45 Integrated Voltage Measurement... 18:41:53 Voltage Offset Correction: v_off_ini = 364.778 uV, v_off_fin = 347.341 uV 18:41:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.794 uVs 18:41:58 I1X Average and RMS of Measurements VT = -135.134 +- 7.076 uVs I1X = 27.027 +- 1.415 uTm 18:42:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:42:04 Integrated Voltage Measurement... 18:42:13 Voltage Offset Correction: v_off_ini = 346.525 uV, v_off_fin = 338.452 uV 18:42:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.703 uVs 18:42:13 Integrated Voltage Measurement... 18:42:22 Voltage Offset Correction: v_off_ini = 342.941 uV, v_off_fin = 356.380 uV 18:42:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.636 uVs 18:42:22 Integrated Voltage Measurement... 18:42:31 Voltage Offset Correction: v_off_ini = 350.791 uV, v_off_fin = 335.857 uV 18:42:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.220 uVs 18:42:31 Integrated Voltage Measurement... 18:42:40 Voltage Offset Correction: v_off_ini = 345.857 uV, v_off_fin = 350.580 uV 18:42:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.905 uVs 18:42:40 Integrated Voltage Measurement... 18:42:49 Voltage Offset Correction: v_off_ini = 332.308 uV, v_off_fin = 342.827 uV 18:42:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.222 uVs 18:42:49 Integrated Voltage Measurement... 18:42:58 Voltage Offset Correction: v_off_ini = 342.519 uV, v_off_fin = 354.673 uV 18:42:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.419 uVs 18:43:02 I1Y Average and RMS of Measurements VT = -205.517 +- 2.541 uVs I1Y = -41.103 +- 0.508 uTm 18:43:07 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:43:10 Integrated Voltage Measurement... 18:43:19 Voltage Offset Correction: v_off_ini = 334.508 uV, v_off_fin = 343.465 uV 18:43:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.017 uVs 18:43:19 Integrated Voltage Measurement... 18:43:28 Voltage Offset Correction: v_off_ini = 358.871 uV, v_off_fin = 347.002 uV 18:43:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.458 uVs 18:43:28 Integrated Voltage Measurement... 18:43:37 Voltage Offset Correction: v_off_ini = 340.482 uV, v_off_fin = 342.910 uV 18:43:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.093 uVs 18:43:37 Integrated Voltage Measurement... 18:43:46 Voltage Offset Correction: v_off_ini = 351.546 uV, v_off_fin = 352.459 uV 18:43:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.271 uVs 18:43:46 Integrated Voltage Measurement... 18:43:55 Voltage Offset Correction: v_off_ini = 353.801 uV, v_off_fin = 357.722 uV 18:43:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.910 uVs 18:43:55 Integrated Voltage Measurement... 18:44:04 Voltage Offset Correction: v_off_ini = 350.290 uV, v_off_fin = 356.229 uV 18:44:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.299 uVs 18:44:06 I2X Average and RMS of Measurements VT = -127.008 +- 8.074 uVs I2X = 11.685 +- 0.743 uTm^2 18:44:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:44:14 Integrated Voltage Measurement... 18:44:23 Voltage Offset Correction: v_off_ini = 343.155 uV, v_off_fin = 357.746 uV 18:44:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.655 uVs 18:44:23 Integrated Voltage Measurement... 18:44:32 Voltage Offset Correction: v_off_ini = 362.889 uV, v_off_fin = 354.118 uV 18:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.290 uVs 18:44:32 Integrated Voltage Measurement... 18:44:41 Voltage Offset Correction: v_off_ini = 360.030 uV, v_off_fin = 350.543 uV 18:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.636 uVs 18:44:41 Integrated Voltage Measurement... 18:44:50 Voltage Offset Correction: v_off_ini = 354.643 uV, v_off_fin = 358.274 uV 18:44:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.684 uVs 18:44:50 Integrated Voltage Measurement... 18:44:59 Voltage Offset Correction: v_off_ini = 360.806 uV, v_off_fin = 350.478 uV 18:44:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.065 uVs 18:44:59 Integrated Voltage Measurement... 18:45:08 Voltage Offset Correction: v_off_ini = 356.230 uV, v_off_fin = 341.746 uV 18:45:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.782 uVs 18:45:11 I2Y Average and RMS of Measurements VT = -240.186 +- 3.522 uVs I2Y = -22.097 +- 0.324 uTm^2 18:45:15 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:45:19 Integrated Voltage Measurement... 18:45:28 Voltage Offset Correction: v_off_ini = 352.418 uV, v_off_fin = 348.951 uV 18:45:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.677 uVs 18:45:28 Integrated Voltage Measurement... 18:45:37 Voltage Offset Correction: v_off_ini = 353.759 uV, v_off_fin = 353.332 uV 18:45:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.417 uVs 18:45:37 Integrated Voltage Measurement... 18:45:46 Voltage Offset Correction: v_off_ini = 344.853 uV, v_off_fin = 340.741 uV 18:45:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.784 uVs 18:45:46 Integrated Voltage Measurement... 18:45:55 Voltage Offset Correction: v_off_ini = 355.392 uV, v_off_fin = 359.026 uV 18:45:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.043 uVs 18:45:55 Integrated Voltage Measurement... 18:46:04 Voltage Offset Correction: v_off_ini = 356.545 uV, v_off_fin = 342.846 uV 18:46:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.167 uVs 18:46:04 Integrated Voltage Measurement... 18:46:13 Voltage Offset Correction: v_off_ini = 361.485 uV, v_off_fin = 360.693 uV 18:46:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.378 uVs 18:46:18 I1X Average and RMS of Measurements VT = -129.744 +- 9.453 uVs I1X = 25.950 +- 1.891 uTm 18:46:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:46:24 Integrated Voltage Measurement... 18:46:33 Voltage Offset Correction: v_off_ini = 349.712 uV, v_off_fin = 333.515 uV 18:46:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.480 uVs 18:46:33 Integrated Voltage Measurement... 18:46:42 Voltage Offset Correction: v_off_ini = 331.514 uV, v_off_fin = 335.205 uV 18:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.458 uVs 18:46:42 Integrated Voltage Measurement... 18:46:51 Voltage Offset Correction: v_off_ini = 352.872 uV, v_off_fin = 326.861 uV 18:46:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.303 uVs 18:46:51 Integrated Voltage Measurement... 18:47:00 Voltage Offset Correction: v_off_ini = 345.226 uV, v_off_fin = 342.918 uV 18:47:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.843 uVs 18:47:00 Integrated Voltage Measurement... 18:47:09 Voltage Offset Correction: v_off_ini = 343.005 uV, v_off_fin = 330.567 uV 18:47:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.929 uVs 18:47:09 Integrated Voltage Measurement... 18:47:18 Voltage Offset Correction: v_off_ini = 328.946 uV, v_off_fin = 353.232 uV 18:47:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.099 uVs 18:47:22 I1Y Average and RMS of Measurements VT = -216.685 +- 5.062 uVs I1Y = -43.337 +- 1.012 uTm 18:47:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:47:30 Integrated Voltage Measurement... 18:47:39 Voltage Offset Correction: v_off_ini = 346.428 uV, v_off_fin = 329.586 uV 18:47:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.536 uVs 18:47:39 Integrated Voltage Measurement... 18:47:48 Voltage Offset Correction: v_off_ini = 340.271 uV, v_off_fin = 339.233 uV 18:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.666 uVs 18:47:48 Integrated Voltage Measurement... 18:47:57 Voltage Offset Correction: v_off_ini = 344.806 uV, v_off_fin = 351.634 uV 18:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.245 uVs 18:47:57 Integrated Voltage Measurement... 18:48:06 Voltage Offset Correction: v_off_ini = 348.119 uV, v_off_fin = 350.955 uV 18:48:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 136.895 uVs 18:48:06 Integrated Voltage Measurement... 18:48:15 Voltage Offset Correction: v_off_ini = 342.711 uV, v_off_fin = 327.258 uV 18:48:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.251 uVs 18:48:15 Integrated Voltage Measurement... 18:48:24 Voltage Offset Correction: v_off_ini = 343.462 uV, v_off_fin = 360.364 uV 18:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.223 uVs 18:48:26 I2X Average and RMS of Measurements VT = -139.636 +- 4.481 uVs I2X = 12.847 +- 0.412 uTm^2 18:48:31 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:48:34 Integrated Voltage Measurement... 18:48:43 Voltage Offset Correction: v_off_ini = 330.086 uV, v_off_fin = 347.420 uV 18:48:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.058 uVs 18:48:43 Integrated Voltage Measurement... 18:48:52 Voltage Offset Correction: v_off_ini = 341.955 uV, v_off_fin = 354.011 uV 18:48:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.491 uVs 18:48:52 Integrated Voltage Measurement... 18:49:01 Voltage Offset Correction: v_off_ini = 351.818 uV, v_off_fin = 355.310 uV 18:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.044 uVs 18:49:01 Integrated Voltage Measurement... 18:49:10 Voltage Offset Correction: v_off_ini = 350.033 uV, v_off_fin = 356.868 uV 18:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.034 uVs 18:49:10 Integrated Voltage Measurement... 18:49:19 Voltage Offset Correction: v_off_ini = 356.261 uV, v_off_fin = 360.453 uV 18:49:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.444 uVs 18:49:19 Integrated Voltage Measurement... 18:49:28 Voltage Offset Correction: v_off_ini = 349.162 uV, v_off_fin = 353.037 uV 18:49:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.566 uVs 18:49:30 I2Y Average and RMS of Measurements VT = -244.273 +- 6.009 uVs I2Y = -22.473 +- 0.553 uTm^2 18:49:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:49:39 Integrated Voltage Measurement... 18:49:48 Voltage Offset Correction: v_off_ini = 355.330 uV, v_off_fin = 353.830 uV 18:49:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.748 uVs 18:49:48 Integrated Voltage Measurement... 18:49:57 Voltage Offset Correction: v_off_ini = 364.422 uV, v_off_fin = 347.775 uV 18:49:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.560 uVs 18:49:57 Integrated Voltage Measurement... 18:50:06 Voltage Offset Correction: v_off_ini = 358.974 uV, v_off_fin = 351.492 uV 18:50:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.791 uVs 18:50:06 Integrated Voltage Measurement... 18:50:15 Voltage Offset Correction: v_off_ini = 361.697 uV, v_off_fin = 362.859 uV 18:50:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.786 uVs 18:50:15 Integrated Voltage Measurement... 18:50:24 Voltage Offset Correction: v_off_ini = 362.511 uV, v_off_fin = 353.239 uV 18:50:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -131.071 uVs 18:50:24 Integrated Voltage Measurement... 18:50:33 Voltage Offset Correction: v_off_ini = 372.350 uV, v_off_fin = 381.243 uV 18:50:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.010 uVs 18:50:37 I1X Average and RMS of Measurements VT = -122.494 +- 4.855 uVs I1X = 24.500 +- 0.971 uTm 18:50:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:50:44 Integrated Voltage Measurement... 18:50:53 Voltage Offset Correction: v_off_ini = 365.708 uV, v_off_fin = 339.880 uV 18:50:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.373 uVs 18:50:53 Integrated Voltage Measurement... 18:51:02 Voltage Offset Correction: v_off_ini = 362.232 uV, v_off_fin = 355.960 uV 18:51:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.309 uVs 18:51:02 Integrated Voltage Measurement... 18:51:11 Voltage Offset Correction: v_off_ini = 375.046 uV, v_off_fin = 340.698 uV 18:51:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.737 uVs 18:51:11 Integrated Voltage Measurement... 18:51:20 Voltage Offset Correction: v_off_ini = 358.607 uV, v_off_fin = 370.387 uV 18:51:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.231 uVs 18:51:20 Integrated Voltage Measurement... 18:51:29 Voltage Offset Correction: v_off_ini = 351.108 uV, v_off_fin = 364.051 uV 18:51:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.176 uVs 18:51:29 Integrated Voltage Measurement... 18:51:38 Voltage Offset Correction: v_off_ini = 369.247 uV, v_off_fin = 370.351 uV 18:51:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.789 uVs 18:51:42 I1Y Average and RMS of Measurements VT = -209.436 +- 2.550 uVs I1Y = -41.887 +- 0.510 uTm 18:51:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:51:50 Integrated Voltage Measurement... 18:51:59 Voltage Offset Correction: v_off_ini = 340.860 uV, v_off_fin = 340.602 uV 18:51:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.301 uVs 18:51:59 Integrated Voltage Measurement... 18:52:08 Voltage Offset Correction: v_off_ini = 343.225 uV, v_off_fin = 355.741 uV 18:52:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.739 uVs 18:52:08 Integrated Voltage Measurement... 18:52:17 Voltage Offset Correction: v_off_ini = 344.356 uV, v_off_fin = 339.422 uV 18:52:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.207 uVs 18:52:17 Integrated Voltage Measurement... 18:52:26 Voltage Offset Correction: v_off_ini = 357.670 uV, v_off_fin = 369.411 uV 18:52:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.946 uVs 18:52:26 Integrated Voltage Measurement... 18:52:35 Voltage Offset Correction: v_off_ini = 357.005 uV, v_off_fin = 340.538 uV 18:52:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -138.132 uVs 18:52:35 Integrated Voltage Measurement... 18:52:44 Voltage Offset Correction: v_off_ini = 338.998 uV, v_off_fin = 365.062 uV 18:52:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.954 uVs 18:52:46 I2X Average and RMS of Measurements VT = -123.713 +- 12.537 uVs I2X = 11.382 +- 1.154 uTm^2 18:52:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:52:54 Integrated Voltage Measurement... 18:53:03 Voltage Offset Correction: v_off_ini = 356.430 uV, v_off_fin = 361.544 uV 18:53:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.226 uVs 18:53:03 Integrated Voltage Measurement... 18:53:12 Voltage Offset Correction: v_off_ini = 344.979 uV, v_off_fin = 365.692 uV 18:53:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.066 uVs 18:53:12 Integrated Voltage Measurement... 18:53:21 Voltage Offset Correction: v_off_ini = 343.183 uV, v_off_fin = 348.012 uV 18:53:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.761 uVs 18:53:21 Integrated Voltage Measurement... 18:53:30 Voltage Offset Correction: v_off_ini = 345.429 uV, v_off_fin = 341.318 uV 18:53:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.156 uVs 18:53:30 Integrated Voltage Measurement... 18:53:39 Voltage Offset Correction: v_off_ini = 365.755 uV, v_off_fin = 362.853 uV 18:53:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.918 uVs 18:53:39 Integrated Voltage Measurement... 18:53:48 Voltage Offset Correction: v_off_ini = 374.396 uV, v_off_fin = 372.539 uV 18:53:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.671 uVs 18:53:50 I2Y Average and RMS of Measurements VT = -250.133 +- 1.912 uVs I2Y = -23.012 +- 0.176 uTm^2 18:53:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:53:59 Integrated Voltage Measurement... 18:54:08 Voltage Offset Correction: v_off_ini = 350.519 uV, v_off_fin = 346.295 uV 18:54:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.626 uVs 18:54:08 Integrated Voltage Measurement... 18:54:17 Voltage Offset Correction: v_off_ini = 365.331 uV, v_off_fin = 361.435 uV 18:54:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.256 uVs 18:54:17 Integrated Voltage Measurement... 18:54:26 Voltage Offset Correction: v_off_ini = 364.628 uV, v_off_fin = 362.450 uV 18:54:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.912 uVs 18:54:26 Integrated Voltage Measurement... 18:54:35 Voltage Offset Correction: v_off_ini = 372.716 uV, v_off_fin = 369.447 uV 18:54:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.366 uVs 18:54:35 Integrated Voltage Measurement... 18:54:44 Voltage Offset Correction: v_off_ini = 369.209 uV, v_off_fin = 353.537 uV 18:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.237 uVs 18:54:44 Integrated Voltage Measurement... 18:54:53 Voltage Offset Correction: v_off_ini = 361.361 uV, v_off_fin = 358.063 uV 18:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.710 uVs 18:54:57 I1X Average and RMS of Measurements VT = -112.685 +- 10.768 uVs I1X = 22.537 +- 2.154 uTm 18:55:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:55:04 Integrated Voltage Measurement... 18:55:13 Voltage Offset Correction: v_off_ini = 376.239 uV, v_off_fin = 365.480 uV 18:55:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.848 uVs 18:55:13 Integrated Voltage Measurement... 18:55:22 Voltage Offset Correction: v_off_ini = 365.784 uV, v_off_fin = 377.776 uV 18:55:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.422 uVs 18:55:22 Integrated Voltage Measurement... 18:55:31 Voltage Offset Correction: v_off_ini = 349.087 uV, v_off_fin = 358.506 uV 18:55:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.508 uVs 18:55:31 Integrated Voltage Measurement... 18:55:40 Voltage Offset Correction: v_off_ini = 360.464 uV, v_off_fin = 368.003 uV 18:55:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.339 uVs 18:55:40 Integrated Voltage Measurement... 18:55:49 Voltage Offset Correction: v_off_ini = 358.861 uV, v_off_fin = 345.835 uV 18:55:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.893 uVs 18:55:49 Integrated Voltage Measurement... 18:55:58 Voltage Offset Correction: v_off_ini = 361.369 uV, v_off_fin = 373.750 uV 18:55:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.723 uVs 18:56:02 I1Y Average and RMS of Measurements VT = -212.955 +- 3.763 uVs I1Y = -42.591 +- 0.753 uTm 18:56:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:56:10 Integrated Voltage Measurement... 18:56:19 Voltage Offset Correction: v_off_ini = 353.357 uV, v_off_fin = 348.507 uV 18:56:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.518 uVs 18:56:19 Integrated Voltage Measurement... 18:56:28 Voltage Offset Correction: v_off_ini = 382.060 uV, v_off_fin = 373.978 uV 18:56:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.127 uVs 18:56:28 Integrated Voltage Measurement... 18:56:37 Voltage Offset Correction: v_off_ini = 354.987 uV, v_off_fin = 359.247 uV 18:56:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.759 uVs 18:56:37 Integrated Voltage Measurement... 18:56:46 Voltage Offset Correction: v_off_ini = 354.340 uV, v_off_fin = 353.242 uV 18:56:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 110.055 uVs 18:56:46 Integrated Voltage Measurement... 18:56:55 Voltage Offset Correction: v_off_ini = 336.428 uV, v_off_fin = 349.283 uV 18:56:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.775 uVs 18:56:55 Integrated Voltage Measurement... 18:57:04 Voltage Offset Correction: v_off_ini = 355.740 uV, v_off_fin = 363.923 uV 18:57:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.961 uVs 18:57:07 I2X Average and RMS of Measurements VT = -113.532 +- 4.465 uVs I2X = 10.445 +- 0.411 uTm^2 18:57:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:57:14 Integrated Voltage Measurement... 18:57:23 Voltage Offset Correction: v_off_ini = 359.921 uV, v_off_fin = 332.293 uV 18:57:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.644 uVs 18:57:23 Integrated Voltage Measurement... 18:57:32 Voltage Offset Correction: v_off_ini = 331.696 uV, v_off_fin = 350.795 uV 18:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.485 uVs 18:57:32 Integrated Voltage Measurement... 18:57:41 Voltage Offset Correction: v_off_ini = 344.832 uV, v_off_fin = 347.455 uV 18:57:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.513 uVs 18:57:41 Integrated Voltage Measurement... 18:57:50 Voltage Offset Correction: v_off_ini = 356.822 uV, v_off_fin = 357.894 uV 18:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.154 uVs 18:57:50 Integrated Voltage Measurement... 18:57:59 Voltage Offset Correction: v_off_ini = 341.445 uV, v_off_fin = 349.490 uV 18:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.050 uVs 18:57:59 Integrated Voltage Measurement... 18:58:08 Voltage Offset Correction: v_off_ini = 336.137 uV, v_off_fin = 349.043 uV 18:58:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.215 uVs 18:58:11 I2Y Average and RMS of Measurements VT = -243.177 +- 10.205 uVs I2Y = -22.372 +- 0.939 uTm^2 18:58:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:58:20 Integrated Voltage Measurement... 18:58:29 Voltage Offset Correction: v_off_ini = 349.842 uV, v_off_fin = 349.323 uV 18:58:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.075 uVs 18:58:29 Integrated Voltage Measurement... 18:58:38 Voltage Offset Correction: v_off_ini = 351.008 uV, v_off_fin = 358.189 uV 18:58:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.860 uVs 18:58:38 Integrated Voltage Measurement... 18:58:47 Voltage Offset Correction: v_off_ini = 352.733 uV, v_off_fin = 346.566 uV 18:58:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.281 uVs 18:58:47 Integrated Voltage Measurement... 18:58:56 Voltage Offset Correction: v_off_ini = 347.377 uV, v_off_fin = 352.726 uV 18:58:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.067 uVs 18:58:56 Integrated Voltage Measurement... 18:59:05 Voltage Offset Correction: v_off_ini = 335.319 uV, v_off_fin = 335.964 uV 18:59:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.690 uVs 18:59:05 Integrated Voltage Measurement... 18:59:14 Voltage Offset Correction: v_off_ini = 343.893 uV, v_off_fin = 340.434 uV 18:59:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.085 uVs 18:59:18 I1X Average and RMS of Measurements VT = -111.676 +- 5.305 uVs I1X = 22.335 +- 1.061 uTm 18:59:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:59:25 Integrated Voltage Measurement... 18:59:34 Voltage Offset Correction: v_off_ini = 355.360 uV, v_off_fin = 334.876 uV 18:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.135 uVs 18:59:34 Integrated Voltage Measurement... 18:59:43 Voltage Offset Correction: v_off_ini = 349.754 uV, v_off_fin = 338.566 uV 18:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.391 uVs 18:59:43 Integrated Voltage Measurement... 18:59:52 Voltage Offset Correction: v_off_ini = 337.171 uV, v_off_fin = 328.884 uV 18:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.993 uVs 18:59:52 Integrated Voltage Measurement... 19:00:01 Voltage Offset Correction: v_off_ini = 351.597 uV, v_off_fin = 354.831 uV 19:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.394 uVs 19:00:01 Integrated Voltage Measurement... 19:00:10 Voltage Offset Correction: v_off_ini = 352.087 uV, v_off_fin = 336.495 uV 19:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.340 uVs 19:00:10 Integrated Voltage Measurement... 19:00:19 Voltage Offset Correction: v_off_ini = 349.922 uV, v_off_fin = 357.089 uV 19:00:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.895 uVs 19:00:23 I1Y Average and RMS of Measurements VT = -220.358 +- 1.063 uVs I1Y = -44.072 +- 0.213 uTm 19:00:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:00:30 Integrated Voltage Measurement... 19:00:39 Voltage Offset Correction: v_off_ini = 370.479 uV, v_off_fin = 351.822 uV 19:00:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.123 uVs 19:00:39 Integrated Voltage Measurement... 19:00:48 Voltage Offset Correction: v_off_ini = 368.419 uV, v_off_fin = 371.409 uV 19:00:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.826 uVs 19:00:49 Integrated Voltage Measurement... 19:00:57 Voltage Offset Correction: v_off_ini = 360.632 uV, v_off_fin = 360.365 uV 19:00:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.646 uVs 19:00:58 Integrated Voltage Measurement... 19:01:06 Voltage Offset Correction: v_off_ini = 360.773 uV, v_off_fin = 373.280 uV 19:01:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.171 uVs 19:01:07 Integrated Voltage Measurement... 19:01:16 Voltage Offset Correction: v_off_ini = 367.198 uV, v_off_fin = 355.641 uV 19:01:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.317 uVs 19:01:16 Integrated Voltage Measurement... 19:01:25 Voltage Offset Correction: v_off_ini = 373.519 uV, v_off_fin = 362.418 uV 19:01:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.952 uVs 19:01:27 I2X Average and RMS of Measurements VT = -108.173 +- 6.933 uVs I2X = 9.952 +- 0.638 uTm^2 19:01:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:01:35 Integrated Voltage Measurement... 19:01:44 Voltage Offset Correction: v_off_ini = 363.773 uV, v_off_fin = 364.506 uV 19:01:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.343 uVs 19:01:44 Integrated Voltage Measurement... 19:01:53 Voltage Offset Correction: v_off_ini = 364.003 uV, v_off_fin = 364.844 uV 19:01:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.396 uVs 19:01:53 Integrated Voltage Measurement... 19:02:02 Voltage Offset Correction: v_off_ini = 363.716 uV, v_off_fin = 372.559 uV 19:02:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.699 uVs 19:02:02 Integrated Voltage Measurement... 19:02:11 Voltage Offset Correction: v_off_ini = 361.939 uV, v_off_fin = 370.531 uV 19:02:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.654 uVs 19:02:11 Integrated Voltage Measurement... 19:02:20 Voltage Offset Correction: v_off_ini = 375.573 uV, v_off_fin = 366.760 uV 19:02:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.289 uVs 19:02:20 Integrated Voltage Measurement... 19:02:29 Voltage Offset Correction: v_off_ini = 369.684 uV, v_off_fin = 387.402 uV 19:02:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.115 uVs 19:02:31 I2Y Average and RMS of Measurements VT = -254.416 +- 6.887 uVs I2Y = -23.406 +- 0.634 uTm^2 19:02:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:02:43 Integrated Voltage Measurement... 19:02:52 Voltage Offset Correction: v_off_ini = 375.510 uV, v_off_fin = 359.752 uV 19:02:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.783 uVs 19:02:52 Integrated Voltage Measurement... 19:03:01 Voltage Offset Correction: v_off_ini = 356.866 uV, v_off_fin = 357.596 uV 19:03:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.115 uVs 19:03:01 Integrated Voltage Measurement... 19:03:10 Voltage Offset Correction: v_off_ini = 374.691 uV, v_off_fin = 362.997 uV 19:03:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.502 uVs 19:03:10 Integrated Voltage Measurement... 19:03:19 Voltage Offset Correction: v_off_ini = 378.419 uV, v_off_fin = 363.380 uV 19:03:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.277 uVs 19:03:19 Integrated Voltage Measurement... 19:03:28 Voltage Offset Correction: v_off_ini = 365.968 uV, v_off_fin = 366.759 uV 19:03:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.404 uVs 19:03:28 Integrated Voltage Measurement... 19:03:37 Voltage Offset Correction: v_off_ini = 373.598 uV, v_off_fin = 355.000 uV 19:03:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.096 uVs 19:03:41 I1X Average and RMS of Measurements VT = -113.030 +- 11.354 uVs I1X = 22.606 +- 2.272 uTm 19:03:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:03:48 Integrated Voltage Measurement... 19:03:57 Voltage Offset Correction: v_off_ini = 351.203 uV, v_off_fin = 353.092 uV 19:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.054 uVs 19:03:57 Integrated Voltage Measurement... 19:04:06 Voltage Offset Correction: v_off_ini = 357.930 uV, v_off_fin = 378.192 uV 19:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.930 uVs 19:04:06 Integrated Voltage Measurement... 19:04:15 Voltage Offset Correction: v_off_ini = 352.732 uV, v_off_fin = 348.877 uV 19:04:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.960 uVs 19:04:15 Integrated Voltage Measurement... 19:04:24 Voltage Offset Correction: v_off_ini = 356.912 uV, v_off_fin = 357.283 uV 19:04:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.742 uVs 19:04:24 Integrated Voltage Measurement... 19:04:33 Voltage Offset Correction: v_off_ini = 349.491 uV, v_off_fin = 350.929 uV 19:04:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.236 uVs 19:04:33 Integrated Voltage Measurement... 19:04:42 Voltage Offset Correction: v_off_ini = 344.983 uV, v_off_fin = 363.267 uV 19:04:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.583 uVs 19:04:46 I1Y Average and RMS of Measurements VT = -219.084 +- 3.648 uVs I1Y = -43.817 +- 0.730 uTm 19:04:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:04:51 Integrated Voltage Measurement... 19:05:00 Voltage Offset Correction: v_off_ini = 344.568 uV, v_off_fin = 348.556 uV 19:05:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.197 uVs 19:05:00 Integrated Voltage Measurement... 19:05:09 Voltage Offset Correction: v_off_ini = 339.252 uV, v_off_fin = 346.390 uV 19:05:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.848 uVs 19:05:10 Integrated Voltage Measurement... 19:05:18 Voltage Offset Correction: v_off_ini = 350.067 uV, v_off_fin = 339.548 uV 19:05:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.373 uVs 19:05:19 Integrated Voltage Measurement... 19:05:28 Voltage Offset Correction: v_off_ini = 344.438 uV, v_off_fin = 350.720 uV 19:05:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.904 uVs 19:05:28 Integrated Voltage Measurement... 19:05:37 Voltage Offset Correction: v_off_ini = 351.413 uV, v_off_fin = 337.491 uV 19:05:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.233 uVs 19:05:37 Integrated Voltage Measurement... 19:05:46 Voltage Offset Correction: v_off_ini = 358.533 uV, v_off_fin = 375.282 uV 19:05:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.242 uVs 19:05:48 I2X Average and RMS of Measurements VT = -121.133 +- 5.125 uVs I2X = 11.144 +- 0.472 uTm^2 19:05:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:05:53 Integrated Voltage Measurement... 19:06:02 Voltage Offset Correction: v_off_ini = 357.613 uV, v_off_fin = 343.066 uV 19:06:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.645 uVs 19:06:02 Integrated Voltage Measurement... 19:06:11 Voltage Offset Correction: v_off_ini = 354.947 uV, v_off_fin = 357.223 uV 19:06:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.462 uVs 19:06:11 Integrated Voltage Measurement... 19:06:20 Voltage Offset Correction: v_off_ini = 347.538 uV, v_off_fin = 338.720 uV 19:06:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.536 uVs 19:06:20 Integrated Voltage Measurement... 19:06:29 Voltage Offset Correction: v_off_ini = 330.558 uV, v_off_fin = 338.063 uV 19:06:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.603 uVs 19:06:29 Integrated Voltage Measurement... 19:06:38 Voltage Offset Correction: v_off_ini = 342.674 uV, v_off_fin = 346.029 uV 19:06:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.100 uVs 19:06:38 Integrated Voltage Measurement... 19:06:47 Voltage Offset Correction: v_off_ini = 335.334 uV, v_off_fin = 336.650 uV 19:06:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 252.057 uVs 19:06:50 I2Y Average and RMS of Measurements VT = -257.567 +- 4.020 uVs I2Y = -23.697 +- 0.369 uTm^2 19:06:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:06:58 Integrated Voltage Measurement... 19:07:07 Voltage Offset Correction: v_off_ini = 334.486 uV, v_off_fin = 321.228 uV 19:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.476 uVs 19:07:07 Integrated Voltage Measurement... 19:07:16 Voltage Offset Correction: v_off_ini = 336.819 uV, v_off_fin = 327.982 uV 19:07:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.677 uVs 19:07:16 Integrated Voltage Measurement... 19:07:25 Voltage Offset Correction: v_off_ini = 330.673 uV, v_off_fin = 336.994 uV 19:07:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.374 uVs 19:07:25 Integrated Voltage Measurement... 19:07:34 Voltage Offset Correction: v_off_ini = 320.941 uV, v_off_fin = 319.345 uV 19:07:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.517 uVs 19:07:34 Integrated Voltage Measurement... 19:07:43 Voltage Offset Correction: v_off_ini = 325.351 uV, v_off_fin = 312.575 uV 19:07:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -124.346 uVs 19:07:43 Integrated Voltage Measurement... 19:07:52 Voltage Offset Correction: v_off_ini = 323.316 uV, v_off_fin = 324.739 uV 19:07:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.459 uVs 19:07:56 I1X Average and RMS of Measurements VT = -121.142 +- 3.829 uVs I1X = 24.230 +- 0.766 uTm 19:07:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:08:03 Integrated Voltage Measurement... 19:08:12 Voltage Offset Correction: v_off_ini = 331.591 uV, v_off_fin = 314.764 uV 19:08:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.452 uVs 19:08:12 Integrated Voltage Measurement... 19:08:21 Voltage Offset Correction: v_off_ini = 325.780 uV, v_off_fin = 344.946 uV 19:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.614 uVs 19:08:21 Integrated Voltage Measurement... 19:08:30 Voltage Offset Correction: v_off_ini = 325.031 uV, v_off_fin = 312.026 uV 19:08:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.299 uVs 19:08:30 Integrated Voltage Measurement... 19:08:39 Voltage Offset Correction: v_off_ini = 312.197 uV, v_off_fin = 334.998 uV 19:08:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.071 uVs 19:08:39 Integrated Voltage Measurement... 19:08:48 Voltage Offset Correction: v_off_ini = 336.521 uV, v_off_fin = 325.181 uV 19:08:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.687 uVs 19:08:48 Integrated Voltage Measurement... 19:08:57 Voltage Offset Correction: v_off_ini = 336.525 uV, v_off_fin = 349.240 uV 19:08:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.820 uVs 19:09:01 I1Y Average and RMS of Measurements VT = -219.657 +- 6.425 uVs I1Y = -43.931 +- 1.285 uTm 19:09:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:09:06 Integrated Voltage Measurement... 19:09:15 Voltage Offset Correction: v_off_ini = 336.459 uV, v_off_fin = 321.243 uV 19:09:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -133.190 uVs 19:09:15 Integrated Voltage Measurement... 19:09:24 Voltage Offset Correction: v_off_ini = 325.270 uV, v_off_fin = 339.048 uV 19:09:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.097 uVs 19:09:24 Integrated Voltage Measurement... 19:09:33 Voltage Offset Correction: v_off_ini = 329.411 uV, v_off_fin = 308.808 uV 19:09:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.223 uVs 19:09:33 Integrated Voltage Measurement... 19:09:42 Voltage Offset Correction: v_off_ini = 321.111 uV, v_off_fin = 330.416 uV 19:09:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.091 uVs 19:09:42 Integrated Voltage Measurement... 19:09:51 Voltage Offset Correction: v_off_ini = 338.485 uV, v_off_fin = 313.781 uV 19:09:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.721 uVs 19:09:51 Integrated Voltage Measurement... 19:10:00 Voltage Offset Correction: v_off_ini = 322.039 uV, v_off_fin = 337.163 uV 19:10:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.235 uVs 19:10:03 I2X Average and RMS of Measurements VT = -124.926 +- 10.727 uVs I2X = 11.493 +- 0.987 uTm^2 19:10:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:10:08 Integrated Voltage Measurement... 19:10:17 Voltage Offset Correction: v_off_ini = 326.586 uV, v_off_fin = 332.334 uV 19:10:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.859 uVs 19:10:17 Integrated Voltage Measurement... 19:10:26 Voltage Offset Correction: v_off_ini = 330.998 uV, v_off_fin = 319.520 uV 19:10:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.059 uVs 19:10:26 Integrated Voltage Measurement... 19:10:35 Voltage Offset Correction: v_off_ini = 332.159 uV, v_off_fin = 320.896 uV 19:10:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.315 uVs 19:10:35 Integrated Voltage Measurement... 19:10:44 Voltage Offset Correction: v_off_ini = 321.268 uV, v_off_fin = 321.227 uV 19:10:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.496 uVs 19:10:44 Integrated Voltage Measurement... 19:10:53 Voltage Offset Correction: v_off_ini = 336.317 uV, v_off_fin = 316.837 uV 19:10:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.500 uVs 19:10:53 Integrated Voltage Measurement... 19:11:02 Voltage Offset Correction: v_off_ini = 322.366 uV, v_off_fin = 324.612 uV 19:11:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.764 uVs 19:11:04 I2Y Average and RMS of Measurements VT = -245.332 +- 1.980 uVs I2Y = -22.571 +- 0.182 uTm^2 19:11:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:11:13 Integrated Voltage Measurement... 19:11:22 Voltage Offset Correction: v_off_ini = 325.723 uV, v_off_fin = 319.128 uV 19:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.929 uVs 19:11:22 Integrated Voltage Measurement... 19:11:31 Voltage Offset Correction: v_off_ini = 317.316 uV, v_off_fin = 314.109 uV 19:11:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 125.065 uVs 19:11:31 Integrated Voltage Measurement... 19:11:40 Voltage Offset Correction: v_off_ini = 315.367 uV, v_off_fin = 297.156 uV 19:11:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.276 uVs 19:11:40 Integrated Voltage Measurement... 19:11:49 Voltage Offset Correction: v_off_ini = 320.321 uV, v_off_fin = 330.644 uV 19:11:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 136.683 uVs 19:11:49 Integrated Voltage Measurement... 19:11:58 Voltage Offset Correction: v_off_ini = 331.354 uV, v_off_fin = 330.013 uV 19:11:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.752 uVs 19:11:58 Integrated Voltage Measurement... 19:12:07 Voltage Offset Correction: v_off_ini = 336.478 uV, v_off_fin = 340.218 uV 19:12:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.403 uVs 19:12:11 I1X Average and RMS of Measurements VT = -125.518 +- 5.313 uVs I1X = 25.105 +- 1.063 uTm 19:12:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:12:18 Integrated Voltage Measurement... 19:12:27 Voltage Offset Correction: v_off_ini = 324.187 uV, v_off_fin = 312.649 uV 19:12:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.301 uVs 19:12:27 Integrated Voltage Measurement... 19:12:36 Voltage Offset Correction: v_off_ini = 330.356 uV, v_off_fin = 340.489 uV 19:12:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.847 uVs 19:12:36 Integrated Voltage Measurement... 19:12:45 Voltage Offset Correction: v_off_ini = 313.616 uV, v_off_fin = 308.929 uV 19:12:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.663 uVs 19:12:45 Integrated Voltage Measurement... 19:12:54 Voltage Offset Correction: v_off_ini = 328.740 uV, v_off_fin = 324.253 uV 19:12:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.101 uVs 19:12:54 Integrated Voltage Measurement... 19:13:03 Voltage Offset Correction: v_off_ini = 325.067 uV, v_off_fin = 318.947 uV 19:13:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.700 uVs 19:13:03 Integrated Voltage Measurement... 19:13:12 Voltage Offset Correction: v_off_ini = 323.646 uV, v_off_fin = 313.806 uV 19:13:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.990 uVs 19:13:16 I1Y Average and RMS of Measurements VT = -211.434 +- 3.811 uVs I1Y = -42.287 +- 0.762 uTm 19:13:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:13:21 Integrated Voltage Measurement... 19:13:30 Voltage Offset Correction: v_off_ini = 332.906 uV, v_off_fin = 326.905 uV 19:13:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.174 uVs 19:13:30 Integrated Voltage Measurement... 19:13:39 Voltage Offset Correction: v_off_ini = 340.046 uV, v_off_fin = 348.548 uV 19:13:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.729 uVs 19:13:39 Integrated Voltage Measurement... 19:13:48 Voltage Offset Correction: v_off_ini = 338.153 uV, v_off_fin = 318.610 uV 19:13:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.634 uVs 19:13:48 Integrated Voltage Measurement... 19:13:57 Voltage Offset Correction: v_off_ini = 342.990 uV, v_off_fin = 330.106 uV 19:13:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.648 uVs 19:13:57 Integrated Voltage Measurement... 19:14:06 Voltage Offset Correction: v_off_ini = 338.149 uV, v_off_fin = 317.779 uV 19:14:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.488 uVs 19:14:06 Integrated Voltage Measurement... 19:14:15 Voltage Offset Correction: v_off_ini = 328.152 uV, v_off_fin = 327.156 uV 19:14:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.339 uVs 19:14:18 I2X Average and RMS of Measurements VT = -128.835 +- 4.477 uVs I2X = 11.853 +- 0.412 uTm^2 19:14:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:14:23 Integrated Voltage Measurement... 19:14:32 Voltage Offset Correction: v_off_ini = 330.711 uV, v_off_fin = 315.137 uV 19:14:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -246.703 uVs 19:14:32 Integrated Voltage Measurement... 19:14:41 Voltage Offset Correction: v_off_ini = 310.194 uV, v_off_fin = 308.923 uV 19:14:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.152 uVs 19:14:41 Integrated Voltage Measurement... 19:14:50 Voltage Offset Correction: v_off_ini = 302.387 uV, v_off_fin = 299.379 uV 19:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.169 uVs 19:14:50 Integrated Voltage Measurement... 19:14:59 Voltage Offset Correction: v_off_ini = 301.836 uV, v_off_fin = 325.137 uV 19:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.541 uVs 19:14:59 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = 310.274 uV, v_off_fin = 304.845 uV 19:15:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.873 uVs 19:15:08 Integrated Voltage Measurement... 19:15:17 Voltage Offset Correction: v_off_ini = 302.689 uV, v_off_fin = 291.960 uV 19:15:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 250.143 uVs 19:15:19 I2Y Average and RMS of Measurements VT = -247.763 +- 5.995 uVs I2Y = -22.794 +- 0.551 uTm^2 19:15:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:15:28 Integrated Voltage Measurement... 19:15:37 Voltage Offset Correction: v_off_ini = 289.567 uV, v_off_fin = 289.713 uV 19:15:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.396 uVs 19:15:37 Integrated Voltage Measurement... 19:15:46 Voltage Offset Correction: v_off_ini = 283.678 uV, v_off_fin = 296.181 uV 19:15:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.150 uVs 19:15:46 Integrated Voltage Measurement... 19:15:55 Voltage Offset Correction: v_off_ini = 294.277 uV, v_off_fin = 285.762 uV 19:15:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.320 uVs 19:15:55 Integrated Voltage Measurement... 19:16:04 Voltage Offset Correction: v_off_ini = 295.244 uV, v_off_fin = 297.758 uV 19:16:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 112.521 uVs 19:16:04 Integrated Voltage Measurement... 19:16:13 Voltage Offset Correction: v_off_ini = 289.483 uV, v_off_fin = 289.715 uV 19:16:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.950 uVs 19:16:13 Integrated Voltage Measurement... 19:16:22 Voltage Offset Correction: v_off_ini = 303.931 uV, v_off_fin = 286.908 uV 19:16:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 82.455 uVs 19:16:26 I1X Average and RMS of Measurements VT = -109.299 +- 6.869 uVs I1X = 21.862 +- 1.375 uTm 19:16:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:16:33 Integrated Voltage Measurement... 19:16:42 Voltage Offset Correction: v_off_ini = 277.684 uV, v_off_fin = 259.472 uV 19:16:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.047 uVs 19:16:42 Integrated Voltage Measurement... 19:16:51 Voltage Offset Correction: v_off_ini = 260.653 uV, v_off_fin = 274.450 uV 19:16:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.903 uVs 19:16:51 Integrated Voltage Measurement... 19:17:00 Voltage Offset Correction: v_off_ini = 266.849 uV, v_off_fin = 260.222 uV 19:17:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.665 uVs 19:17:00 Integrated Voltage Measurement... 19:17:09 Voltage Offset Correction: v_off_ini = 272.158 uV, v_off_fin = 284.905 uV 19:17:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.057 uVs 19:17:09 Integrated Voltage Measurement... 19:17:18 Voltage Offset Correction: v_off_ini = 269.968 uV, v_off_fin = 259.619 uV 19:17:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.062 uVs 19:17:18 Integrated Voltage Measurement... 19:17:27 Voltage Offset Correction: v_off_ini = 292.763 uV, v_off_fin = 286.404 uV 19:17:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.029 uVs 19:17:31 I1Y Average and RMS of Measurements VT = -207.294 +- 9.321 uVs I1Y = -41.457 +- 1.864 uTm 19:17:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:17:36 Integrated Voltage Measurement... 19:17:45 Voltage Offset Correction: v_off_ini = 299.640 uV, v_off_fin = 291.504 uV 19:17:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.154 uVs 19:17:45 Integrated Voltage Measurement... 19:17:54 Voltage Offset Correction: v_off_ini = 286.893 uV, v_off_fin = 305.641 uV 19:17:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.252 uVs 19:17:54 Integrated Voltage Measurement... 19:18:03 Voltage Offset Correction: v_off_ini = 298.819 uV, v_off_fin = 268.535 uV 19:18:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.733 uVs 19:18:03 Integrated Voltage Measurement... 19:18:12 Voltage Offset Correction: v_off_ini = 294.808 uV, v_off_fin = 294.332 uV 19:18:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.006 uVs 19:18:12 Integrated Voltage Measurement... 19:18:21 Voltage Offset Correction: v_off_ini = 291.893 uV, v_off_fin = 280.245 uV 19:18:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.359 uVs 19:18:22 Integrated Voltage Measurement... 19:18:30 Voltage Offset Correction: v_off_ini = 291.397 uV, v_off_fin = 288.971 uV 19:18:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 116.208 uVs 19:18:33 I2X Average and RMS of Measurements VT = -118.619 +- 9.254 uVs I2X = 10.913 +- 0.851 uTm^2 19:18:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:18:38 Integrated Voltage Measurement... 19:18:47 Voltage Offset Correction: v_off_ini = 285.770 uV, v_off_fin = 283.216 uV 19:18:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -225.753 uVs 19:18:47 Integrated Voltage Measurement... 19:18:56 Voltage Offset Correction: v_off_ini = 287.809 uV, v_off_fin = 299.258 uV 19:18:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.773 uVs 19:18:56 Integrated Voltage Measurement... 19:19:05 Voltage Offset Correction: v_off_ini = 298.838 uV, v_off_fin = 291.095 uV 19:19:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.769 uVs 19:19:05 Integrated Voltage Measurement... 19:19:14 Voltage Offset Correction: v_off_ini = 282.759 uV, v_off_fin = 292.995 uV 19:19:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.204 uVs 19:19:14 Integrated Voltage Measurement... 19:19:23 Voltage Offset Correction: v_off_ini = 308.208 uV, v_off_fin = 301.701 uV 19:19:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.146 uVs 19:19:23 Integrated Voltage Measurement... 19:19:32 Voltage Offset Correction: v_off_ini = 313.404 uV, v_off_fin = 294.801 uV 19:19:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.917 uVs 19:19:35 I2Y Average and RMS of Measurements VT = -237.927 +- 6.425 uVs I2Y = -21.890 +- 0.591 uTm^2 19:19:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:19:43 Integrated Voltage Measurement... 19:19:52 Voltage Offset Correction: v_off_ini = 292.633 uV, v_off_fin = 298.765 uV 19:19:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.249 uVs 19:19:52 Integrated Voltage Measurement... 19:20:01 Voltage Offset Correction: v_off_ini = 295.836 uV, v_off_fin = 300.937 uV 19:20:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.078 uVs 19:20:01 Integrated Voltage Measurement... 19:20:10 Voltage Offset Correction: v_off_ini = 286.359 uV, v_off_fin = 293.786 uV 19:20:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.699 uVs 19:20:10 Integrated Voltage Measurement... 19:20:19 Voltage Offset Correction: v_off_ini = 308.165 uV, v_off_fin = 299.745 uV 19:20:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.015 uVs 19:20:19 Integrated Voltage Measurement... 19:20:28 Voltage Offset Correction: v_off_ini = 284.427 uV, v_off_fin = 292.543 uV 19:20:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.901 uVs 19:20:28 Integrated Voltage Measurement... 19:20:37 Voltage Offset Correction: v_off_ini = 310.403 uV, v_off_fin = 315.887 uV 19:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.105 uVs 19:20:41 I1X Average and RMS of Measurements VT = -114.175 +- 2.968 uVs I1X = 22.835 +- 0.594 uTm 19:20:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:20:48 Integrated Voltage Measurement... 19:20:57 Voltage Offset Correction: v_off_ini = 305.878 uV, v_off_fin = 298.207 uV 19:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.944 uVs 19:20:57 Integrated Voltage Measurement... 19:21:06 Voltage Offset Correction: v_off_ini = 308.308 uV, v_off_fin = 310.571 uV 19:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 219.660 uVs 19:21:06 Integrated Voltage Measurement... 19:21:15 Voltage Offset Correction: v_off_ini = 302.091 uV, v_off_fin = 316.533 uV 19:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -215.392 uVs 19:21:15 Integrated Voltage Measurement... 19:21:24 Voltage Offset Correction: v_off_ini = 313.840 uV, v_off_fin = 327.385 uV 19:21:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.340 uVs 19:21:24 Integrated Voltage Measurement... 19:21:33 Voltage Offset Correction: v_off_ini = 325.321 uV, v_off_fin = 315.232 uV 19:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.688 uVs 19:21:33 Integrated Voltage Measurement... 19:21:42 Voltage Offset Correction: v_off_ini = 323.358 uV, v_off_fin = 328.610 uV 19:21:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 194.455 uVs 19:21:46 I1Y Average and RMS of Measurements VT = -208.246 +- 5.092 uVs I1Y = -41.644 +- 1.019 uTm 19:21:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:21:51 Integrated Voltage Measurement... 19:22:00 Voltage Offset Correction: v_off_ini = 303.137 uV, v_off_fin = 293.908 uV 19:22:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.483 uVs 19:22:00 Integrated Voltage Measurement... 19:22:09 Voltage Offset Correction: v_off_ini = 310.526 uV, v_off_fin = 316.697 uV 19:22:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.357 uVs 19:22:10 Integrated Voltage Measurement... 19:22:19 Voltage Offset Correction: v_off_ini = 302.780 uV, v_off_fin = 290.926 uV 19:22:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.793 uVs 19:22:19 Integrated Voltage Measurement... 19:22:28 Voltage Offset Correction: v_off_ini = 302.007 uV, v_off_fin = 308.357 uV 19:22:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.076 uVs 19:22:28 Integrated Voltage Measurement... 19:22:37 Voltage Offset Correction: v_off_ini = 314.481 uV, v_off_fin = 297.736 uV 19:22:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.437 uVs 19:22:37 Integrated Voltage Measurement... 19:22:46 Voltage Offset Correction: v_off_ini = 301.315 uV, v_off_fin = 302.530 uV 19:22:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.562 uVs 19:22:48 I2X Average and RMS of Measurements VT = -113.618 +- 12.830 uVs I2X = 10.453 +- 1.180 uTm^2 19:22:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:22:53 Integrated Voltage Measurement... 19:23:02 Voltage Offset Correction: v_off_ini = 286.762 uV, v_off_fin = 300.399 uV 19:23:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.644 uVs 19:23:02 Integrated Voltage Measurement... 19:23:11 Voltage Offset Correction: v_off_ini = 298.468 uV, v_off_fin = 282.210 uV 19:23:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.392 uVs 19:23:11 Integrated Voltage Measurement... 19:23:20 Voltage Offset Correction: v_off_ini = 301.725 uV, v_off_fin = 293.331 uV 19:23:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.094 uVs 19:23:20 Integrated Voltage Measurement... 19:23:29 Voltage Offset Correction: v_off_ini = 302.183 uV, v_off_fin = 304.579 uV 19:23:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.877 uVs 19:23:29 Integrated Voltage Measurement... 19:23:38 Voltage Offset Correction: v_off_ini = 281.509 uV, v_off_fin = 291.488 uV 19:23:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.557 uVs 19:23:38 Integrated Voltage Measurement... 19:23:47 Voltage Offset Correction: v_off_ini = 292.170 uV, v_off_fin = 290.703 uV 19:23:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.796 uVs 19:23:50 I2Y Average and RMS of Measurements VT = -234.393 +- 2.584 uVs I2Y = -21.564 +- 0.238 uTm^2 19:24:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:24:25 Integrated Voltage Measurement... 19:24:34 Voltage Offset Correction: v_off_ini = 294.976 uV, v_off_fin = 286.904 uV 19:24:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.963 uVs 19:24:34 Integrated Voltage Measurement... 19:24:43 Voltage Offset Correction: v_off_ini = 286.101 uV, v_off_fin = 297.208 uV 19:24:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.432 uVs 19:24:43 Integrated Voltage Measurement... 19:24:52 Voltage Offset Correction: v_off_ini = 287.623 uV, v_off_fin = 285.631 uV 19:24:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.403 uVs 19:24:52 Integrated Voltage Measurement... 19:25:01 Voltage Offset Correction: v_off_ini = 290.702 uV, v_off_fin = 287.759 uV 19:25:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.074 uVs 19:25:01 Integrated Voltage Measurement... 19:25:10 Voltage Offset Correction: v_off_ini = 295.185 uV, v_off_fin = 272.684 uV 19:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.664 uVs 19:25:10 Integrated Voltage Measurement... 19:25:19 Voltage Offset Correction: v_off_ini = 296.999 uV, v_off_fin = 301.364 uV 19:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.733 uVs 19:25:23 I1X Average and RMS of Measurements VT = -86.545 +- 6.310 uVs I1X = 17.309 +- 1.262 uTm 19:25:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:25:30 Integrated Voltage Measurement... 19:25:39 Voltage Offset Correction: v_off_ini = 278.660 uV, v_off_fin = 262.305 uV 19:25:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -176.785 uVs 19:25:39 Integrated Voltage Measurement... 19:25:48 Voltage Offset Correction: v_off_ini = 273.230 uV, v_off_fin = 285.270 uV 19:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.636 uVs 19:25:48 Integrated Voltage Measurement... 19:25:57 Voltage Offset Correction: v_off_ini = 271.228 uV, v_off_fin = 279.120 uV 19:25:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.980 uVs 19:25:57 Integrated Voltage Measurement... 19:26:06 Voltage Offset Correction: v_off_ini = 291.361 uV, v_off_fin = 304.114 uV 19:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.757 uVs 19:26:06 Integrated Voltage Measurement... 19:26:15 Voltage Offset Correction: v_off_ini = 290.714 uV, v_off_fin = 276.353 uV 19:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.177 uVs 19:26:15 Integrated Voltage Measurement... 19:26:24 Voltage Offset Correction: v_off_ini = 276.973 uV, v_off_fin = 287.420 uV 19:26:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.556 uVs 19:26:28 I1Y Average and RMS of Measurements VT = -175.815 +- 2.285 uVs I1Y = -35.164 +- 0.457 uTm 19:26:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:26:36 Integrated Voltage Measurement... 19:26:45 Voltage Offset Correction: v_off_ini = 271.719 uV, v_off_fin = 271.054 uV 19:26:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.561 uVs 19:26:45 Integrated Voltage Measurement... 19:26:54 Voltage Offset Correction: v_off_ini = 269.876 uV, v_off_fin = 311.832 uV 19:26:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.659 uVs 19:26:54 Integrated Voltage Measurement... 19:27:03 Voltage Offset Correction: v_off_ini = 288.137 uV, v_off_fin = 288.310 uV 19:27:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.298 uVs 19:27:03 Integrated Voltage Measurement... 19:27:12 Voltage Offset Correction: v_off_ini = 298.830 uV, v_off_fin = 297.061 uV 19:27:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.223 uVs 19:27:12 Integrated Voltage Measurement... 19:27:21 Voltage Offset Correction: v_off_ini = 291.771 uV, v_off_fin = 288.773 uV 19:27:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.682 uVs 19:27:21 Integrated Voltage Measurement... 19:27:30 Voltage Offset Correction: v_off_ini = 296.875 uV, v_off_fin = 299.177 uV 19:27:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.283 uVs 19:27:33 I2X Average and RMS of Measurements VT = -86.784 +- 2.517 uVs I2X = 7.984 +- 0.232 uTm^2 19:27:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:27:41 Integrated Voltage Measurement... 19:27:50 Voltage Offset Correction: v_off_ini = 288.980 uV, v_off_fin = 289.538 uV 19:27:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.825 uVs 19:27:50 Integrated Voltage Measurement... 19:27:59 Voltage Offset Correction: v_off_ini = 307.829 uV, v_off_fin = 309.276 uV 19:27:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.971 uVs 19:27:59 Integrated Voltage Measurement... 19:28:08 Voltage Offset Correction: v_off_ini = 301.080 uV, v_off_fin = 299.142 uV 19:28:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.635 uVs 19:28:08 Integrated Voltage Measurement... 19:28:17 Voltage Offset Correction: v_off_ini = 289.779 uV, v_off_fin = 288.370 uV 19:28:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.377 uVs 19:28:17 Integrated Voltage Measurement... 19:28:26 Voltage Offset Correction: v_off_ini = 296.343 uV, v_off_fin = 278.340 uV 19:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.844 uVs 19:28:26 Integrated Voltage Measurement... 19:28:35 Voltage Offset Correction: v_off_ini = 285.786 uV, v_off_fin = 299.400 uV 19:28:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.712 uVs 19:28:37 I2Y Average and RMS of Measurements VT = -191.727 +- 5.752 uVs I2Y = -17.639 +- 0.529 uTm^2 19:28:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:28:46 Integrated Voltage Measurement... 19:28:55 Voltage Offset Correction: v_off_ini = 309.469 uV, v_off_fin = 305.302 uV 19:28:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.072 uVs 19:28:55 Integrated Voltage Measurement... 19:29:04 Voltage Offset Correction: v_off_ini = 293.710 uV, v_off_fin = 285.768 uV 19:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.685 uVs 19:29:04 Integrated Voltage Measurement... 19:29:13 Voltage Offset Correction: v_off_ini = 283.882 uV, v_off_fin = 278.838 uV 19:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.881 uVs 19:29:13 Integrated Voltage Measurement... 19:29:22 Voltage Offset Correction: v_off_ini = 297.223 uV, v_off_fin = 283.734 uV 19:29:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.652 uVs 19:29:22 Integrated Voltage Measurement... 19:29:31 Voltage Offset Correction: v_off_ini = 286.872 uV, v_off_fin = 283.695 uV 19:29:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -91.568 uVs 19:29:31 Integrated Voltage Measurement... 19:29:40 Voltage Offset Correction: v_off_ini = 286.613 uV, v_off_fin = 309.861 uV 19:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 106.468 uVs 19:29:44 I1X Average and RMS of Measurements VT = -85.721 +- 10.720 uVs I1X = 17.145 +- 2.145 uTm 19:29:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:29:51 Integrated Voltage Measurement... 19:30:00 Voltage Offset Correction: v_off_ini = 307.518 uV, v_off_fin = 298.382 uV 19:30:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -202.024 uVs 19:30:00 Integrated Voltage Measurement... 19:30:09 Voltage Offset Correction: v_off_ini = 307.534 uV, v_off_fin = 312.246 uV 19:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.855 uVs 19:30:09 Integrated Voltage Measurement... 19:30:18 Voltage Offset Correction: v_off_ini = 299.410 uV, v_off_fin = 291.649 uV 19:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.928 uVs 19:30:18 Integrated Voltage Measurement... 19:30:27 Voltage Offset Correction: v_off_ini = 291.801 uV, v_off_fin = 306.615 uV 19:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.154 uVs 19:30:27 Integrated Voltage Measurement... 19:30:36 Voltage Offset Correction: v_off_ini = 301.031 uV, v_off_fin = 285.436 uV 19:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.027 uVs 19:30:36 Integrated Voltage Measurement... 19:30:45 Voltage Offset Correction: v_off_ini = 289.654 uV, v_off_fin = 286.305 uV 19:30:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.309 uVs 19:30:49 I1Y Average and RMS of Measurements VT = -185.050 +- 7.738 uVs I1Y = -37.012 +- 1.549 uTm 19:30:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:30:57 Integrated Voltage Measurement... 19:31:06 Voltage Offset Correction: v_off_ini = 276.841 uV, v_off_fin = 270.856 uV 19:31:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.089 uVs 19:31:06 Integrated Voltage Measurement... 19:31:15 Voltage Offset Correction: v_off_ini = 269.735 uV, v_off_fin = 272.593 uV 19:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.265 uVs 19:31:15 Integrated Voltage Measurement... 19:31:24 Voltage Offset Correction: v_off_ini = 260.358 uV, v_off_fin = 250.771 uV 19:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.271 uVs 19:31:24 Integrated Voltage Measurement... 19:31:33 Voltage Offset Correction: v_off_ini = 263.543 uV, v_off_fin = 266.154 uV 19:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.028 uVs 19:31:33 Integrated Voltage Measurement... 19:31:42 Voltage Offset Correction: v_off_ini = 265.678 uV, v_off_fin = 264.822 uV 19:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.729 uVs 19:31:42 Integrated Voltage Measurement... 19:31:51 Voltage Offset Correction: v_off_ini = 276.318 uV, v_off_fin = 272.823 uV 19:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.585 uVs 19:31:54 I2X Average and RMS of Measurements VT = -82.161 +- 6.576 uVs I2X = 7.559 +- 0.605 uTm^2 19:31:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:32:02 Integrated Voltage Measurement... 19:32:11 Voltage Offset Correction: v_off_ini = 277.109 uV, v_off_fin = 271.845 uV 19:32:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.615 uVs 19:32:11 Integrated Voltage Measurement... 19:32:20 Voltage Offset Correction: v_off_ini = 282.500 uV, v_off_fin = 269.097 uV 19:32:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.551 uVs 19:32:20 Integrated Voltage Measurement... 19:32:29 Voltage Offset Correction: v_off_ini = 269.658 uV, v_off_fin = 265.093 uV 19:32:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.971 uVs 19:32:29 Integrated Voltage Measurement... 19:32:38 Voltage Offset Correction: v_off_ini = 278.583 uV, v_off_fin = 273.384 uV 19:32:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.346 uVs 19:32:38 Integrated Voltage Measurement... 19:32:47 Voltage Offset Correction: v_off_ini = 271.430 uV, v_off_fin = 262.121 uV 19:32:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.849 uVs 19:32:47 Integrated Voltage Measurement... 19:32:56 Voltage Offset Correction: v_off_ini = 265.661 uV, v_off_fin = 256.333 uV 19:32:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.521 uVs 19:32:58 I2Y Average and RMS of Measurements VT = -193.809 +- 4.506 uVs I2Y = -17.830 +- 0.415 uTm^2 19:33:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:33:07 Integrated Voltage Measurement... 19:33:16 Voltage Offset Correction: v_off_ini = 267.311 uV, v_off_fin = 258.991 uV 19:33:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.884 uVs 19:33:16 Integrated Voltage Measurement... 19:33:25 Voltage Offset Correction: v_off_ini = 252.055 uV, v_off_fin = 256.006 uV 19:33:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 79.311 uVs 19:33:25 Integrated Voltage Measurement... 19:33:34 Voltage Offset Correction: v_off_ini = 257.505 uV, v_off_fin = 237.449 uV 19:33:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.659 uVs 19:33:34 Integrated Voltage Measurement... 19:33:43 Voltage Offset Correction: v_off_ini = 242.541 uV, v_off_fin = 249.409 uV 19:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.088 uVs 19:33:43 Integrated Voltage Measurement... 19:33:52 Voltage Offset Correction: v_off_ini = 231.160 uV, v_off_fin = 232.697 uV 19:33:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.968 uVs 19:33:52 Integrated Voltage Measurement... 19:34:01 Voltage Offset Correction: v_off_ini = 249.265 uV, v_off_fin = 248.035 uV 19:34:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.951 uVs 19:34:05 I1X Average and RMS of Measurements VT = -84.977 +- 5.780 uVs I1X = 16.996 +- 1.156 uTm 19:34:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:34:12 Integrated Voltage Measurement... 19:34:21 Voltage Offset Correction: v_off_ini = 248.041 uV, v_off_fin = 236.022 uV 19:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.621 uVs 19:34:21 Integrated Voltage Measurement... 19:34:30 Voltage Offset Correction: v_off_ini = 243.399 uV, v_off_fin = 235.882 uV 19:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.752 uVs 19:34:30 Integrated Voltage Measurement... 19:34:39 Voltage Offset Correction: v_off_ini = 244.773 uV, v_off_fin = 234.808 uV 19:34:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.939 uVs 19:34:39 Integrated Voltage Measurement... 19:34:48 Voltage Offset Correction: v_off_ini = 240.393 uV, v_off_fin = 242.100 uV 19:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.021 uVs 19:34:48 Integrated Voltage Measurement... 19:34:57 Voltage Offset Correction: v_off_ini = 237.841 uV, v_off_fin = 236.224 uV 19:34:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.723 uVs 19:34:57 Integrated Voltage Measurement... 19:35:06 Voltage Offset Correction: v_off_ini = 245.912 uV, v_off_fin = 253.108 uV 19:35:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.430 uVs 19:35:10 I1Y Average and RMS of Measurements VT = -182.748 +- 0.313 uVs I1Y = -36.550 +- 0.063 uTm 19:35:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:35:18 Integrated Voltage Measurement... 19:35:27 Voltage Offset Correction: v_off_ini = 248.399 uV, v_off_fin = 246.415 uV 19:35:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.312 uVs 19:35:27 Integrated Voltage Measurement... 19:35:36 Voltage Offset Correction: v_off_ini = 253.067 uV, v_off_fin = 252.521 uV 19:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.756 uVs 19:35:36 Integrated Voltage Measurement... 19:35:45 Voltage Offset Correction: v_off_ini = 251.698 uV, v_off_fin = 242.104 uV 19:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.085 uVs 19:35:45 Integrated Voltage Measurement... 19:35:54 Voltage Offset Correction: v_off_ini = 228.321 uV, v_off_fin = 253.506 uV 19:35:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.695 uVs 19:35:54 Integrated Voltage Measurement... 19:36:03 Voltage Offset Correction: v_off_ini = 247.989 uV, v_off_fin = 251.199 uV 19:36:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.561 uVs 19:36:03 Integrated Voltage Measurement... 19:36:12 Voltage Offset Correction: v_off_ini = 269.782 uV, v_off_fin = 271.070 uV 19:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.405 uVs 19:36:15 I2X Average and RMS of Measurements VT = -94.136 +- 9.420 uVs I2X = 8.660 +- 0.867 uTm^2 19:36:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:36:23 Integrated Voltage Measurement... 19:36:31 Voltage Offset Correction: v_off_ini = 242.172 uV, v_off_fin = 242.127 uV 19:36:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.004 uVs 19:36:32 Integrated Voltage Measurement... 19:36:41 Voltage Offset Correction: v_off_ini = 256.330 uV, v_off_fin = 253.636 uV 19:36:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.919 uVs 19:36:41 Integrated Voltage Measurement... 19:36:50 Voltage Offset Correction: v_off_ini = 247.704 uV, v_off_fin = 240.717 uV 19:36:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.288 uVs 19:36:50 Integrated Voltage Measurement... 19:36:59 Voltage Offset Correction: v_off_ini = 232.901 uV, v_off_fin = 239.185 uV 19:36:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.163 uVs 19:36:59 Integrated Voltage Measurement... 19:37:08 Voltage Offset Correction: v_off_ini = 255.032 uV, v_off_fin = 267.231 uV 19:37:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.891 uVs 19:37:08 Integrated Voltage Measurement... 19:37:17 Voltage Offset Correction: v_off_ini = 271.132 uV, v_off_fin = 266.799 uV 19:37:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.775 uVs 19:37:19 I2Y Average and RMS of Measurements VT = -190.007 +- 5.283 uVs I2Y = -17.481 +- 0.486 uTm^2 19:37:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:37:28 Integrated Voltage Measurement... 19:37:37 Voltage Offset Correction: v_off_ini = 250.605 uV, v_off_fin = 247.953 uV 19:37:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -85.425 uVs 19:37:37 Integrated Voltage Measurement... 19:37:46 Voltage Offset Correction: v_off_ini = 244.692 uV, v_off_fin = 248.491 uV 19:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.038 uVs 19:37:46 Integrated Voltage Measurement... 19:37:55 Voltage Offset Correction: v_off_ini = 246.169 uV, v_off_fin = 239.993 uV 19:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.651 uVs 19:37:55 Integrated Voltage Measurement... 19:38:04 Voltage Offset Correction: v_off_ini = 237.514 uV, v_off_fin = 251.051 uV 19:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.686 uVs 19:38:04 Integrated Voltage Measurement... 19:38:13 Voltage Offset Correction: v_off_ini = 245.740 uV, v_off_fin = 238.938 uV 19:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.720 uVs 19:38:13 Integrated Voltage Measurement... 19:38:22 Voltage Offset Correction: v_off_ini = 227.576 uV, v_off_fin = 235.401 uV 19:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.266 uVs 19:38:26 I1X Average and RMS of Measurements VT = -88.298 +- 6.410 uVs I1X = 17.660 +- 1.281 uTm 19:38:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:38:33 Integrated Voltage Measurement... 19:38:42 Voltage Offset Correction: v_off_ini = 241.021 uV, v_off_fin = 240.426 uV 19:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.322 uVs 19:38:42 Integrated Voltage Measurement... 19:38:51 Voltage Offset Correction: v_off_ini = 253.871 uV, v_off_fin = 253.417 uV 19:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.321 uVs 19:38:51 Integrated Voltage Measurement... 19:39:00 Voltage Offset Correction: v_off_ini = 249.711 uV, v_off_fin = 228.780 uV 19:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.052 uVs 19:39:00 Integrated Voltage Measurement... 19:39:09 Voltage Offset Correction: v_off_ini = 233.041 uV, v_off_fin = 237.866 uV 19:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.130 uVs 19:39:09 Integrated Voltage Measurement... 19:39:18 Voltage Offset Correction: v_off_ini = 229.298 uV, v_off_fin = 228.537 uV 19:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.540 uVs 19:39:18 Integrated Voltage Measurement... 19:39:27 Voltage Offset Correction: v_off_ini = 228.303 uV, v_off_fin = 247.308 uV 19:39:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.515 uVs 19:39:31 I1Y Average and RMS of Measurements VT = -179.480 +- 4.001 uVs I1Y = -35.896 +- 0.800 uTm 19:39:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:39:39 Integrated Voltage Measurement... 19:39:48 Voltage Offset Correction: v_off_ini = 223.296 uV, v_off_fin = 220.578 uV 19:39:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.873 uVs 19:39:48 Integrated Voltage Measurement... 19:39:57 Voltage Offset Correction: v_off_ini = 230.194 uV, v_off_fin = 241.133 uV 19:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.573 uVs 19:39:57 Integrated Voltage Measurement... 19:40:06 Voltage Offset Correction: v_off_ini = 218.868 uV, v_off_fin = 212.507 uV 19:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.051 uVs 19:40:06 Integrated Voltage Measurement... 19:40:15 Voltage Offset Correction: v_off_ini = 226.159 uV, v_off_fin = 235.597 uV 19:40:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.453 uVs 19:40:15 Integrated Voltage Measurement... 19:40:24 Voltage Offset Correction: v_off_ini = 227.064 uV, v_off_fin = 212.428 uV 19:40:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.327 uVs 19:40:24 Integrated Voltage Measurement... 19:40:33 Voltage Offset Correction: v_off_ini = 214.000 uV, v_off_fin = 222.586 uV 19:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.278 uVs 19:40:36 I2X Average and RMS of Measurements VT = -72.426 +- 6.340 uVs I2X = 6.663 +- 0.583 uTm^2 19:40:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:40:43 Integrated Voltage Measurement... 19:40:52 Voltage Offset Correction: v_off_ini = 212.237 uV, v_off_fin = 207.556 uV 19:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.990 uVs 19:40:52 Integrated Voltage Measurement... 19:41:01 Voltage Offset Correction: v_off_ini = 202.780 uV, v_off_fin = 197.537 uV 19:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 207.239 uVs 19:41:01 Integrated Voltage Measurement... 19:41:10 Voltage Offset Correction: v_off_ini = 202.794 uV, v_off_fin = 198.187 uV 19:41:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.072 uVs 19:41:10 Integrated Voltage Measurement... 19:41:19 Voltage Offset Correction: v_off_ini = 212.556 uV, v_off_fin = 214.983 uV 19:41:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.962 uVs 19:41:19 Integrated Voltage Measurement... 19:41:28 Voltage Offset Correction: v_off_ini = 206.664 uV, v_off_fin = 218.084 uV 19:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.577 uVs 19:41:29 Integrated Voltage Measurement... 19:41:37 Voltage Offset Correction: v_off_ini = 221.155 uV, v_off_fin = 212.255 uV 19:41:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.507 uVs 19:41:40 I2Y Average and RMS of Measurements VT = -194.224 +- 6.835 uVs I2Y = -17.869 +- 0.629 uTm^2 19:41:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:41:49 Integrated Voltage Measurement... 19:41:58 Voltage Offset Correction: v_off_ini = 213.992 uV, v_off_fin = 204.749 uV 19:41:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -70.866 uVs 19:41:58 Integrated Voltage Measurement... 19:42:07 Voltage Offset Correction: v_off_ini = 211.633 uV, v_off_fin = 209.445 uV 19:42:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.132 uVs 19:42:07 Integrated Voltage Measurement... 19:42:16 Voltage Offset Correction: v_off_ini = 212.581 uV, v_off_fin = 192.278 uV 19:42:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.657 uVs 19:42:16 Integrated Voltage Measurement... 19:42:25 Voltage Offset Correction: v_off_ini = 194.611 uV, v_off_fin = 190.571 uV 19:42:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.398 uVs 19:42:25 Integrated Voltage Measurement... 19:42:34 Voltage Offset Correction: v_off_ini = 195.338 uV, v_off_fin = 192.999 uV 19:42:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.845 uVs 19:42:34 Integrated Voltage Measurement... 19:42:43 Voltage Offset Correction: v_off_ini = 189.758 uV, v_off_fin = 196.430 uV 19:42:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.661 uVs 19:42:47 I1X Average and RMS of Measurements VT = -85.593 +- 6.158 uVs I1X = 17.119 +- 1.231 uTm 19:42:50 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:42:54 Integrated Voltage Measurement... 19:43:03 Voltage Offset Correction: v_off_ini = 192.940 uV, v_off_fin = 178.400 uV 19:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.496 uVs 19:43:03 Integrated Voltage Measurement... 19:43:12 Voltage Offset Correction: v_off_ini = 190.960 uV, v_off_fin = 211.619 uV 19:43:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.458 uVs 19:43:12 Integrated Voltage Measurement... 19:43:21 Voltage Offset Correction: v_off_ini = 182.706 uV, v_off_fin = 179.939 uV 19:43:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.581 uVs 19:43:21 Integrated Voltage Measurement... 19:43:30 Voltage Offset Correction: v_off_ini = 199.925 uV, v_off_fin = 203.610 uV 19:43:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.141 uVs 19:43:30 Integrated Voltage Measurement... 19:43:39 Voltage Offset Correction: v_off_ini = 188.673 uV, v_off_fin = 192.649 uV 19:43:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.452 uVs 19:43:39 Integrated Voltage Measurement... 19:43:48 Voltage Offset Correction: v_off_ini = 206.977 uV, v_off_fin = 206.242 uV 19:43:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.821 uVs 19:43:52 I1Y Average and RMS of Measurements VT = -176.991 +- 5.634 uVs I1Y = -35.398 +- 1.127 uTm 19:43:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:44:00 Integrated Voltage Measurement... 19:44:09 Voltage Offset Correction: v_off_ini = 183.299 uV, v_off_fin = 188.955 uV 19:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.395 uVs 19:44:09 Integrated Voltage Measurement... 19:44:18 Voltage Offset Correction: v_off_ini = 191.182 uV, v_off_fin = 211.751 uV 19:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.944 uVs 19:44:18 Integrated Voltage Measurement... 19:44:27 Voltage Offset Correction: v_off_ini = 206.712 uV, v_off_fin = 202.385 uV 19:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.057 uVs 19:44:27 Integrated Voltage Measurement... 19:44:36 Voltage Offset Correction: v_off_ini = 206.443 uV, v_off_fin = 202.364 uV 19:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.443 uVs 19:44:36 Integrated Voltage Measurement... 19:44:45 Voltage Offset Correction: v_off_ini = 208.062 uV, v_off_fin = 200.418 uV 19:44:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.338 uVs 19:44:45 Integrated Voltage Measurement... 19:44:54 Voltage Offset Correction: v_off_ini = 197.817 uV, v_off_fin = 207.226 uV 19:44:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.788 uVs 19:44:56 I2X Average and RMS of Measurements VT = -88.161 +- 5.642 uVs I2X = 8.111 +- 0.519 uTm^2 19:45:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:45:04 Integrated Voltage Measurement... 19:45:13 Voltage Offset Correction: v_off_ini = 211.417 uV, v_off_fin = 196.386 uV 19:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.707 uVs 19:45:13 Integrated Voltage Measurement... 19:45:22 Voltage Offset Correction: v_off_ini = 199.013 uV, v_off_fin = 200.587 uV 19:45:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.359 uVs 19:45:22 Integrated Voltage Measurement... 19:45:31 Voltage Offset Correction: v_off_ini = 191.072 uV, v_off_fin = 189.896 uV 19:45:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.221 uVs 19:45:31 Integrated Voltage Measurement... 19:45:40 Voltage Offset Correction: v_off_ini = 202.893 uV, v_off_fin = 202.075 uV 19:45:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.400 uVs 19:45:40 Integrated Voltage Measurement... 19:45:49 Voltage Offset Correction: v_off_ini = 191.267 uV, v_off_fin = 184.362 uV 19:45:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.847 uVs 19:45:49 Integrated Voltage Measurement... 19:45:58 Voltage Offset Correction: v_off_ini = 197.207 uV, v_off_fin = 198.617 uV 19:45:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.892 uVs 19:46:00 I2Y Average and RMS of Measurements VT = -197.571 +- 14.872 uVs I2Y = -18.177 +- 1.368 uTm^2 19:46:08 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:46:12 Integrated Voltage Measurement... 19:46:21 Voltage Offset Correction: v_off_ini = 199.950 uV, v_off_fin = 182.012 uV 19:46:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -79.598 uVs 19:46:21 Integrated Voltage Measurement... 19:46:30 Voltage Offset Correction: v_off_ini = 197.305 uV, v_off_fin = 201.101 uV 19:46:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 82.795 uVs 19:46:30 Integrated Voltage Measurement... 19:46:39 Voltage Offset Correction: v_off_ini = 214.018 uV, v_off_fin = 197.592 uV 19:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.194 uVs 19:46:39 Integrated Voltage Measurement... 19:46:48 Voltage Offset Correction: v_off_ini = 207.304 uV, v_off_fin = 212.258 uV 19:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.954 uVs 19:46:48 Integrated Voltage Measurement... 19:46:57 Voltage Offset Correction: v_off_ini = 210.970 uV, v_off_fin = 194.258 uV 19:46:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.862 uVs 19:46:57 Integrated Voltage Measurement... 19:47:06 Voltage Offset Correction: v_off_ini = 198.720 uV, v_off_fin = 206.570 uV 19:47:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.920 uVs 19:47:11 I1X Average and RMS of Measurements VT = -88.387 +- 5.107 uVs I1X = 17.679 +- 1.020 uTm 19:47:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:47:17 Integrated Voltage Measurement... 19:47:26 Voltage Offset Correction: v_off_ini = 185.208 uV, v_off_fin = 182.862 uV 19:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.083 uVs 19:47:26 Integrated Voltage Measurement... 19:47:35 Voltage Offset Correction: v_off_ini = 211.043 uV, v_off_fin = 221.789 uV 19:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.724 uVs 19:47:35 Integrated Voltage Measurement... 19:47:44 Voltage Offset Correction: v_off_ini = 212.709 uV, v_off_fin = 198.401 uV 19:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.657 uVs 19:47:44 Integrated Voltage Measurement... 19:47:53 Voltage Offset Correction: v_off_ini = 198.356 uV, v_off_fin = 213.717 uV 19:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 189.385 uVs 19:47:53 Integrated Voltage Measurement... 19:48:02 Voltage Offset Correction: v_off_ini = 222.519 uV, v_off_fin = 222.178 uV 19:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.600 uVs 19:48:02 Integrated Voltage Measurement... 19:48:11 Voltage Offset Correction: v_off_ini = 224.312 uV, v_off_fin = 243.723 uV 19:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.316 uVs 19:48:15 I1Y Average and RMS of Measurements VT = -186.294 +- 4.597 uVs I1Y = -37.259 +- 0.920 uTm 19:48:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:48:21 Integrated Voltage Measurement... 19:48:30 Voltage Offset Correction: v_off_ini = 206.840 uV, v_off_fin = 208.509 uV 19:48:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.193 uVs 19:48:30 Integrated Voltage Measurement... 19:48:39 Voltage Offset Correction: v_off_ini = 202.589 uV, v_off_fin = 221.509 uV 19:48:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.440 uVs 19:48:39 Integrated Voltage Measurement... 19:48:48 Voltage Offset Correction: v_off_ini = 231.430 uV, v_off_fin = 212.800 uV 19:48:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.617 uVs 19:48:48 Integrated Voltage Measurement... 19:48:57 Voltage Offset Correction: v_off_ini = 223.241 uV, v_off_fin = 231.936 uV 19:48:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.796 uVs 19:48:57 Integrated Voltage Measurement... 19:49:06 Voltage Offset Correction: v_off_ini = 220.223 uV, v_off_fin = 210.268 uV 19:49:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.001 uVs 19:49:06 Integrated Voltage Measurement... 19:49:15 Voltage Offset Correction: v_off_ini = 220.378 uV, v_off_fin = 229.613 uV 19:49:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.299 uVs 19:49:17 I2X Average and RMS of Measurements VT = -81.724 +- 3.869 uVs I2X = 7.519 +- 0.356 uTm^2 19:49:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:49:22 Integrated Voltage Measurement... 19:49:31 Voltage Offset Correction: v_off_ini = 212.198 uV, v_off_fin = 219.348 uV 19:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.979 uVs 19:49:31 Integrated Voltage Measurement... 19:49:40 Voltage Offset Correction: v_off_ini = 213.634 uV, v_off_fin = 213.849 uV 19:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.858 uVs 19:49:40 Integrated Voltage Measurement... 19:49:49 Voltage Offset Correction: v_off_ini = 223.405 uV, v_off_fin = 221.023 uV 19:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.625 uVs 19:49:49 Integrated Voltage Measurement... 19:49:58 Voltage Offset Correction: v_off_ini = 217.744 uV, v_off_fin = 224.750 uV 19:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.965 uVs 19:49:58 Integrated Voltage Measurement... 19:50:07 Voltage Offset Correction: v_off_ini = 214.396 uV, v_off_fin = 227.794 uV 19:50:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -183.521 uVs 19:50:07 Integrated Voltage Measurement... 19:50:16 Voltage Offset Correction: v_off_ini = 228.146 uV, v_off_fin = 228.021 uV 19:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.453 uVs 19:50:19 I2Y Average and RMS of Measurements VT = -205.067 +- 5.895 uVs I2Y = -18.866 +- 0.542 uTm^2 19:50:23 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:50:27 Integrated Voltage Measurement... 19:50:36 Voltage Offset Correction: v_off_ini = 214.789 uV, v_off_fin = 217.684 uV 19:50:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.233 uVs 19:50:36 Integrated Voltage Measurement... 19:50:45 Voltage Offset Correction: v_off_ini = 215.526 uV, v_off_fin = 222.465 uV 19:50:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.231 uVs 19:50:45 Integrated Voltage Measurement... 19:50:54 Voltage Offset Correction: v_off_ini = 211.530 uV, v_off_fin = 209.863 uV 19:50:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.373 uVs 19:50:54 Integrated Voltage Measurement... 19:51:03 Voltage Offset Correction: v_off_ini = 197.845 uV, v_off_fin = 218.576 uV 19:51:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.829 uVs 19:51:03 Integrated Voltage Measurement... 19:51:12 Voltage Offset Correction: v_off_ini = 213.887 uV, v_off_fin = 204.987 uV 19:51:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.264 uVs 19:51:12 Integrated Voltage Measurement... 19:51:21 Voltage Offset Correction: v_off_ini = 217.203 uV, v_off_fin = 214.179 uV 19:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.563 uVs 19:51:25 I1X Average and RMS of Measurements VT = -81.915 +- 6.238 uVs I1X = 16.383 +- 1.248 uTm 19:51:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:51:32 Integrated Voltage Measurement... 19:51:41 Voltage Offset Correction: v_off_ini = 211.556 uV, v_off_fin = 203.446 uV 19:51:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.383 uVs 19:51:41 Integrated Voltage Measurement... 19:51:50 Voltage Offset Correction: v_off_ini = 207.557 uV, v_off_fin = 222.284 uV 19:51:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.396 uVs 19:51:50 Integrated Voltage Measurement... 19:51:59 Voltage Offset Correction: v_off_ini = 201.742 uV, v_off_fin = 203.249 uV 19:51:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.520 uVs 19:51:59 Integrated Voltage Measurement... 19:52:08 Voltage Offset Correction: v_off_ini = 229.299 uV, v_off_fin = 241.460 uV 19:52:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.786 uVs 19:52:08 Integrated Voltage Measurement... 19:52:17 Voltage Offset Correction: v_off_ini = 224.164 uV, v_off_fin = 206.479 uV 19:52:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.594 uVs 19:52:17 Integrated Voltage Measurement... 19:52:26 Voltage Offset Correction: v_off_ini = 214.479 uV, v_off_fin = 225.031 uV 19:52:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.276 uVs 19:52:30 I1Y Average and RMS of Measurements VT = -179.992 +- 3.840 uVs I1Y = -35.998 +- 0.768 uTm 19:52:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:52:35 Integrated Voltage Measurement... 19:52:44 Voltage Offset Correction: v_off_ini = 235.093 uV, v_off_fin = 219.135 uV 19:52:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.647 uVs 19:52:44 Integrated Voltage Measurement... 19:52:53 Voltage Offset Correction: v_off_ini = 227.048 uV, v_off_fin = 240.091 uV 19:52:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.540 uVs 19:52:53 Integrated Voltage Measurement... 19:53:02 Voltage Offset Correction: v_off_ini = 230.379 uV, v_off_fin = 216.856 uV 19:53:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.807 uVs 19:53:02 Integrated Voltage Measurement... 19:53:11 Voltage Offset Correction: v_off_ini = 215.728 uV, v_off_fin = 231.877 uV 19:53:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.804 uVs 19:53:11 Integrated Voltage Measurement... 19:53:20 Voltage Offset Correction: v_off_ini = 212.687 uV, v_off_fin = 207.085 uV 19:53:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.733 uVs 19:53:20 Integrated Voltage Measurement... 19:53:29 Voltage Offset Correction: v_off_ini = 221.663 uV, v_off_fin = 219.129 uV 19:53:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.610 uVs 19:53:32 I2X Average and RMS of Measurements VT = -82.524 +- 6.559 uVs I2X = 7.592 +- 0.603 uTm^2 19:53:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:53:37 Integrated Voltage Measurement... 19:53:46 Voltage Offset Correction: v_off_ini = 213.634 uV, v_off_fin = 196.523 uV 19:53:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.041 uVs 19:53:46 Integrated Voltage Measurement... 19:53:55 Voltage Offset Correction: v_off_ini = 217.943 uV, v_off_fin = 220.531 uV 19:53:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 192.033 uVs 19:53:55 Integrated Voltage Measurement... 19:54:04 Voltage Offset Correction: v_off_ini = 207.767 uV, v_off_fin = 193.491 uV 19:54:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.199 uVs 19:54:04 Integrated Voltage Measurement... 19:54:13 Voltage Offset Correction: v_off_ini = 206.241 uV, v_off_fin = 206.706 uV 19:54:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.915 uVs 19:54:13 Integrated Voltage Measurement... 19:54:22 Voltage Offset Correction: v_off_ini = 206.446 uV, v_off_fin = 207.129 uV 19:54:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.974 uVs 19:54:22 Integrated Voltage Measurement... 19:54:31 Voltage Offset Correction: v_off_ini = 196.512 uV, v_off_fin = 206.343 uV 19:54:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.637 uVs 19:54:34 I2Y Average and RMS of Measurements VT = -193.800 +- 7.101 uVs I2Y = -17.830 +- 0.654 uTm^2 19:54:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:54:42 Integrated Voltage Measurement... 19:54:51 Voltage Offset Correction: v_off_ini = 221.229 uV, v_off_fin = 209.793 uV 19:54:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -95.986 uVs 19:54:51 Integrated Voltage Measurement... 19:55:00 Voltage Offset Correction: v_off_ini = 225.489 uV, v_off_fin = 226.261 uV 19:55:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.144 uVs 19:55:00 Integrated Voltage Measurement... 19:55:09 Voltage Offset Correction: v_off_ini = 225.193 uV, v_off_fin = 195.461 uV 19:55:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.969 uVs 19:55:09 Integrated Voltage Measurement... 19:55:18 Voltage Offset Correction: v_off_ini = 191.887 uV, v_off_fin = 201.059 uV 19:55:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 72.705 uVs 19:55:18 Integrated Voltage Measurement... 19:55:27 Voltage Offset Correction: v_off_ini = 202.483 uV, v_off_fin = 205.750 uV 19:55:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.131 uVs 19:55:27 Integrated Voltage Measurement... 19:55:36 Voltage Offset Correction: v_off_ini = 211.916 uV, v_off_fin = 201.946 uV 19:55:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.470 uVs 19:55:40 I1X Average and RMS of Measurements VT = -85.401 +- 5.372 uVs I1X = 17.081 +- 1.074 uTm 19:55:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:55:47 Integrated Voltage Measurement... 19:55:56 Voltage Offset Correction: v_off_ini = 197.117 uV, v_off_fin = 188.333 uV 19:55:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.552 uVs 19:55:56 Integrated Voltage Measurement... 19:56:05 Voltage Offset Correction: v_off_ini = 194.285 uV, v_off_fin = 207.604 uV 19:56:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.866 uVs 19:56:05 Integrated Voltage Measurement... 19:56:14 Voltage Offset Correction: v_off_ini = 207.434 uV, v_off_fin = 184.783 uV 19:56:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.651 uVs 19:56:14 Integrated Voltage Measurement... 19:56:23 Voltage Offset Correction: v_off_ini = 188.457 uV, v_off_fin = 193.575 uV 19:56:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.558 uVs 19:56:23 Integrated Voltage Measurement... 19:56:32 Voltage Offset Correction: v_off_ini = 188.581 uV, v_off_fin = 196.317 uV 19:56:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.623 uVs 19:56:32 Integrated Voltage Measurement... 19:56:41 Voltage Offset Correction: v_off_ini = 215.474 uV, v_off_fin = 215.622 uV 19:56:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.621 uVs 19:56:45 I1Y Average and RMS of Measurements VT = -181.978 +- 1.894 uVs I1Y = -36.396 +- 0.379 uTm 19:56:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:56:50 Integrated Voltage Measurement... 19:56:59 Voltage Offset Correction: v_off_ini = 203.288 uV, v_off_fin = 194.982 uV 19:57:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.200 uVs 19:57:00 Integrated Voltage Measurement... 19:57:08 Voltage Offset Correction: v_off_ini = 207.369 uV, v_off_fin = 224.126 uV 19:57:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.440 uVs 19:57:09 Integrated Voltage Measurement... 19:57:18 Voltage Offset Correction: v_off_ini = 217.319 uV, v_off_fin = 202.270 uV 19:57:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.441 uVs 19:57:18 Integrated Voltage Measurement... 19:57:27 Voltage Offset Correction: v_off_ini = 226.879 uV, v_off_fin = 230.154 uV 19:57:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.348 uVs 19:57:27 Integrated Voltage Measurement... 19:57:36 Voltage Offset Correction: v_off_ini = 235.805 uV, v_off_fin = 220.101 uV 19:57:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.716 uVs 19:57:36 Integrated Voltage Measurement... 19:57:45 Voltage Offset Correction: v_off_ini = 226.763 uV, v_off_fin = 239.860 uV 19:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.009 uVs 19:57:47 I2X Average and RMS of Measurements VT = -87.192 +- 8.836 uVs I2X = 8.022 +- 0.813 uTm^2 19:57:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:57:52 Integrated Voltage Measurement... 19:58:01 Voltage Offset Correction: v_off_ini = 226.682 uV, v_off_fin = 210.841 uV 19:58:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.414 uVs 19:58:01 Integrated Voltage Measurement... 19:58:10 Voltage Offset Correction: v_off_ini = 240.243 uV, v_off_fin = 227.604 uV 19:58:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.235 uVs 19:58:10 Integrated Voltage Measurement... 19:58:19 Voltage Offset Correction: v_off_ini = 226.989 uV, v_off_fin = 233.321 uV 19:58:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.562 uVs 19:58:19 Integrated Voltage Measurement... 19:58:28 Voltage Offset Correction: v_off_ini = 236.957 uV, v_off_fin = 214.045 uV 19:58:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.041 uVs 19:58:28 Integrated Voltage Measurement... 19:58:37 Voltage Offset Correction: v_off_ini = 214.752 uV, v_off_fin = 206.469 uV 19:58:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.441 uVs 19:58:37 Integrated Voltage Measurement... 19:58:46 Voltage Offset Correction: v_off_ini = 217.098 uV, v_off_fin = 215.460 uV 19:58:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.920 uVs 19:58:49 I2Y Average and RMS of Measurements VT = -190.769 +- 5.666 uVs I2Y = -17.551 +- 0.521 uTm^2 19:58:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:58:57 Integrated Voltage Measurement... 19:59:06 Voltage Offset Correction: v_off_ini = 230.185 uV, v_off_fin = 227.409 uV 19:59:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.346 uVs 19:59:06 Integrated Voltage Measurement... 19:59:15 Voltage Offset Correction: v_off_ini = 224.473 uV, v_off_fin = 227.633 uV 19:59:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.788 uVs 19:59:15 Integrated Voltage Measurement... 19:59:24 Voltage Offset Correction: v_off_ini = 218.287 uV, v_off_fin = 229.973 uV 19:59:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.413 uVs 19:59:24 Integrated Voltage Measurement... 19:59:33 Voltage Offset Correction: v_off_ini = 233.518 uV, v_off_fin = 223.865 uV 19:59:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.859 uVs 19:59:33 Integrated Voltage Measurement... 19:59:42 Voltage Offset Correction: v_off_ini = 217.488 uV, v_off_fin = 222.193 uV 19:59:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.565 uVs 19:59:42 Integrated Voltage Measurement... 19:59:51 Voltage Offset Correction: v_off_ini = 229.782 uV, v_off_fin = 244.294 uV 19:59:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.548 uVs 19:59:56 I1X Average and RMS of Measurements VT = -70.753 +- 10.902 uVs I1X = 14.151 +- 2.181 uTm 19:59:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:00:02 Integrated Voltage Measurement... 20:00:11 Voltage Offset Correction: v_off_ini = 211.634 uV, v_off_fin = 200.154 uV 20:00:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.772 uVs 20:00:11 Integrated Voltage Measurement... 20:00:20 Voltage Offset Correction: v_off_ini = 231.229 uV, v_off_fin = 229.359 uV 20:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.070 uVs 20:00:20 Integrated Voltage Measurement... 20:00:29 Voltage Offset Correction: v_off_ini = 234.162 uV, v_off_fin = 204.264 uV 20:00:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.787 uVs 20:00:29 Integrated Voltage Measurement... 20:00:38 Voltage Offset Correction: v_off_ini = 224.961 uV, v_off_fin = 222.590 uV 20:00:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.502 uVs 20:00:38 Integrated Voltage Measurement... 20:00:47 Voltage Offset Correction: v_off_ini = 213.139 uV, v_off_fin = 202.426 uV 20:00:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.532 uVs 20:00:47 Integrated Voltage Measurement... 20:00:56 Voltage Offset Correction: v_off_ini = 223.549 uV, v_off_fin = 217.376 uV 20:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 164.723 uVs 20:01:00 I1Y Average and RMS of Measurements VT = -181.898 +- 4.526 uVs I1Y = -36.377 +- 0.906 uTm 20:01:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:01:06 Integrated Voltage Measurement... 20:01:15 Voltage Offset Correction: v_off_ini = 222.684 uV, v_off_fin = 214.602 uV 20:01:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.041 uVs 20:01:15 Integrated Voltage Measurement... 20:01:24 Voltage Offset Correction: v_off_ini = 221.815 uV, v_off_fin = 231.465 uV 20:01:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.389 uVs 20:01:24 Integrated Voltage Measurement... 20:01:33 Voltage Offset Correction: v_off_ini = 232.839 uV, v_off_fin = 220.996 uV 20:01:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.015 uVs 20:01:33 Integrated Voltage Measurement... 20:01:42 Voltage Offset Correction: v_off_ini = 199.859 uV, v_off_fin = 228.673 uV 20:01:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.151 uVs 20:01:42 Integrated Voltage Measurement... 20:01:51 Voltage Offset Correction: v_off_ini = 213.697 uV, v_off_fin = 211.368 uV 20:01:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.935 uVs 20:01:51 Integrated Voltage Measurement... 20:02:00 Voltage Offset Correction: v_off_ini = 222.254 uV, v_off_fin = 226.678 uV 20:02:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.573 uVs 20:02:02 I2X Average and RMS of Measurements VT = -78.517 +- 7.016 uVs I2X = 7.224 +- 0.646 uTm^2 20:02:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:02:07 Integrated Voltage Measurement... 20:02:16 Voltage Offset Correction: v_off_ini = 213.800 uV, v_off_fin = 227.242 uV 20:02:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.976 uVs 20:02:16 Integrated Voltage Measurement... 20:02:25 Voltage Offset Correction: v_off_ini = 215.727 uV, v_off_fin = 215.647 uV 20:02:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.639 uVs 20:02:25 Integrated Voltage Measurement... 20:02:34 Voltage Offset Correction: v_off_ini = 233.528 uV, v_off_fin = 221.130 uV 20:02:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.062 uVs 20:02:35 Integrated Voltage Measurement... 20:02:43 Voltage Offset Correction: v_off_ini = 226.682 uV, v_off_fin = 226.061 uV 20:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.550 uVs 20:02:44 Integrated Voltage Measurement... 20:02:53 Voltage Offset Correction: v_off_ini = 215.739 uV, v_off_fin = 222.935 uV 20:02:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -177.215 uVs 20:02:53 Integrated Voltage Measurement... 20:03:02 Voltage Offset Correction: v_off_ini = 225.301 uV, v_off_fin = 216.948 uV 20:03:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.201 uVs 20:03:04 I2Y Average and RMS of Measurements VT = -190.441 +- 3.794 uVs I2Y = -17.521 +- 0.349 uTm^2 20:03:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:03:12 Integrated Voltage Measurement... 20:03:21 Voltage Offset Correction: v_off_ini = 246.888 uV, v_off_fin = 229.869 uV 20:03:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.555 uVs 20:03:21 Integrated Voltage Measurement... 20:03:30 Voltage Offset Correction: v_off_ini = 228.534 uV, v_off_fin = 237.091 uV 20:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.447 uVs 20:03:30 Integrated Voltage Measurement... 20:03:39 Voltage Offset Correction: v_off_ini = 233.592 uV, v_off_fin = 233.842 uV 20:03:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.332 uVs 20:03:39 Integrated Voltage Measurement... 20:03:48 Voltage Offset Correction: v_off_ini = 241.054 uV, v_off_fin = 245.025 uV 20:03:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.697 uVs 20:03:48 Integrated Voltage Measurement... 20:03:57 Voltage Offset Correction: v_off_ini = 235.822 uV, v_off_fin = 240.657 uV 20:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.320 uVs 20:03:57 Integrated Voltage Measurement... 20:04:06 Voltage Offset Correction: v_off_ini = 236.778 uV, v_off_fin = 237.122 uV 20:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.562 uVs 20:04:11 I1X Average and RMS of Measurements VT = -83.319 +- 7.663 uVs I1X = 16.664 +- 1.533 uTm 20:04:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:04:17 Integrated Voltage Measurement... 20:04:26 Voltage Offset Correction: v_off_ini = 223.879 uV, v_off_fin = 214.062 uV 20:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.683 uVs 20:04:26 Integrated Voltage Measurement... 20:04:35 Voltage Offset Correction: v_off_ini = 225.749 uV, v_off_fin = 240.655 uV 20:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.996 uVs 20:04:35 Integrated Voltage Measurement... 20:04:44 Voltage Offset Correction: v_off_ini = 235.662 uV, v_off_fin = 213.100 uV 20:04:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.217 uVs 20:04:44 Integrated Voltage Measurement... 20:04:53 Voltage Offset Correction: v_off_ini = 232.757 uV, v_off_fin = 240.125 uV 20:04:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.366 uVs 20:04:53 Integrated Voltage Measurement... 20:05:02 Voltage Offset Correction: v_off_ini = 237.832 uV, v_off_fin = 218.840 uV 20:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.249 uVs 20:05:02 Integrated Voltage Measurement... 20:05:11 Voltage Offset Correction: v_off_ini = 222.057 uV, v_off_fin = 236.771 uV 20:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.215 uVs 20:05:16 I1Y Average and RMS of Measurements VT = -180.121 +- 5.906 uVs I1Y = -36.021 +- 1.181 uTm 20:05:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:05:21 Integrated Voltage Measurement... 20:05:30 Voltage Offset Correction: v_off_ini = 230.013 uV, v_off_fin = 229.130 uV 20:05:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.468 uVs 20:05:30 Integrated Voltage Measurement... 20:05:39 Voltage Offset Correction: v_off_ini = 225.018 uV, v_off_fin = 224.496 uV 20:05:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.054 uVs 20:05:39 Integrated Voltage Measurement... 20:05:48 Voltage Offset Correction: v_off_ini = 209.102 uV, v_off_fin = 205.258 uV 20:05:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.390 uVs 20:05:48 Integrated Voltage Measurement... 20:05:57 Voltage Offset Correction: v_off_ini = 211.708 uV, v_off_fin = 216.677 uV 20:05:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.451 uVs 20:05:57 Integrated Voltage Measurement... 20:06:06 Voltage Offset Correction: v_off_ini = 221.071 uV, v_off_fin = 205.107 uV 20:06:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.288 uVs 20:06:06 Integrated Voltage Measurement... 20:06:15 Voltage Offset Correction: v_off_ini = 191.484 uV, v_off_fin = 209.059 uV 20:06:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.977 uVs 20:06:17 I2X Average and RMS of Measurements VT = -85.771 +- 6.480 uVs I2X = 7.891 +- 0.596 uTm^2 20:06:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:06:23 Integrated Voltage Measurement... 20:06:32 Voltage Offset Correction: v_off_ini = 201.744 uV, v_off_fin = 203.177 uV 20:06:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.057 uVs 20:06:32 Integrated Voltage Measurement... 20:06:41 Voltage Offset Correction: v_off_ini = 219.534 uV, v_off_fin = 203.221 uV 20:06:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.311 uVs 20:06:41 Integrated Voltage Measurement... 20:06:50 Voltage Offset Correction: v_off_ini = 208.506 uV, v_off_fin = 200.831 uV 20:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.604 uVs 20:06:50 Integrated Voltage Measurement... 20:06:59 Voltage Offset Correction: v_off_ini = 205.922 uV, v_off_fin = 204.620 uV 20:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.240 uVs 20:06:59 Integrated Voltage Measurement... 20:07:08 Voltage Offset Correction: v_off_ini = 203.921 uV, v_off_fin = 201.455 uV 20:07:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.562 uVs 20:07:08 Integrated Voltage Measurement... 20:07:17 Voltage Offset Correction: v_off_ini = 219.865 uV, v_off_fin = 219.371 uV 20:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.638 uVs 20:07:19 I2Y Average and RMS of Measurements VT = -187.235 +- 0.840 uVs I2Y = -17.226 +- 0.077 uTm^2 20:07:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:19:04 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm