SLAC Magnetic Measurements Date: 05-19-2025 Time: 19:27:18 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HESXPS_16337 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 1 Measurement Device: On Axis Operator: YL Comment: 19:27:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:27:27 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 19:27:29 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 19:27:31 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 19:27:32 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 19:27:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:27:54 Integrated Voltage Measurement... 19:28:03 Voltage Offset Correction: v_off_ini = 653.106 uV, v_off_fin = 637.161 uV 19:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.360 uVs 19:28:03 Integrated Voltage Measurement... 19:28:12 Voltage Offset Correction: v_off_ini = 614.327 uV, v_off_fin = 624.115 uV 19:28:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.477 uVs 19:28:12 Integrated Voltage Measurement... 19:28:21 Voltage Offset Correction: v_off_ini = 628.784 uV, v_off_fin = 638.115 uV 19:28:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.843 uVs 19:28:21 Integrated Voltage Measurement... 19:28:30 Voltage Offset Correction: v_off_ini = 651.386 uV, v_off_fin = 641.912 uV 19:28:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.617 uVs 19:28:30 Integrated Voltage Measurement... 19:28:39 Voltage Offset Correction: v_off_ini = 647.235 uV, v_off_fin = 637.926 uV 19:28:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.428 uVs 19:28:39 Integrated Voltage Measurement... 19:28:48 Voltage Offset Correction: v_off_ini = 644.047 uV, v_off_fin = 669.217 uV 19:28:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.453 uVs 19:28:52 I1X Average and RMS of Measurements VT = -79.696 +- 11.304 uVs I1X = 15.939 +- 2.261 uTm 19:28:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:28:59 Integrated Voltage Measurement... 19:29:08 Voltage Offset Correction: v_off_ini = 668.341 uV, v_off_fin = 644.433 uV 19:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.298 uVs 19:29:08 Integrated Voltage Measurement... 19:29:17 Voltage Offset Correction: v_off_ini = 647.423 uV, v_off_fin = 651.884 uV 19:29:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.014 uVs 19:29:17 Integrated Voltage Measurement... 19:29:26 Voltage Offset Correction: v_off_ini = 641.079 uV, v_off_fin = 626.106 uV 19:29:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.662 uVs 19:29:26 Integrated Voltage Measurement... 19:29:35 Voltage Offset Correction: v_off_ini = 635.547 uV, v_off_fin = 643.327 uV 19:29:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.663 uVs 19:29:35 Integrated Voltage Measurement... 19:29:44 Voltage Offset Correction: v_off_ini = 666.682 uV, v_off_fin = 622.906 uV 19:29:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.116 uVs 19:29:44 Integrated Voltage Measurement... 19:29:53 Voltage Offset Correction: v_off_ini = 642.070 uV, v_off_fin = 665.190 uV 19:29:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.085 uVs 19:29:57 I1Y Average and RMS of Measurements VT = -237.473 +- 2.867 uVs I1Y = -47.495 +- 0.573 uTm 19:30:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:30:05 Integrated Voltage Measurement... 19:30:14 Voltage Offset Correction: v_off_ini = 663.043 uV, v_off_fin = 660.977 uV 19:30:14 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -76.695 uVs 19:30:14 Integrated Voltage Measurement... 19:30:23 Voltage Offset Correction: v_off_ini = 654.440 uV, v_off_fin = 648.089 uV 19:30:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.716 uVs 19:30:23 Integrated Voltage Measurement... 19:30:32 Voltage Offset Correction: v_off_ini = 665.764 uV, v_off_fin = 655.188 uV 19:30:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.449 uVs 19:30:32 Integrated Voltage Measurement... 19:30:41 Voltage Offset Correction: v_off_ini = 656.649 uV, v_off_fin = 625.059 uV 19:30:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.935 uVs 19:30:41 Integrated Voltage Measurement... 19:30:50 Voltage Offset Correction: v_off_ini = 629.819 uV, v_off_fin = 651.188 uV 19:30:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.924 uVs 19:30:50 Integrated Voltage Measurement... 19:30:59 Voltage Offset Correction: v_off_ini = 641.430 uV, v_off_fin = 648.298 uV 19:30:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.894 uVs 19:31:01 I2X Average and RMS of Measurements VT = -71.602 +- 5.359 uVs I2X = 6.587 +- 0.493 uTm^2 19:31:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:31:09 Integrated Voltage Measurement... 19:31:18 Voltage Offset Correction: v_off_ini = 643.388 uV, v_off_fin = 646.070 uV 19:31:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -106.926 uVs 19:31:18 Integrated Voltage Measurement... 19:31:27 Voltage Offset Correction: v_off_ini = 659.853 uV, v_off_fin = 662.473 uV 19:31:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 103.277 uVs 19:31:27 Integrated Voltage Measurement... 19:31:36 Voltage Offset Correction: v_off_ini = 660.314 uV, v_off_fin = 644.689 uV 19:31:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -129.778 uVs 19:31:36 Integrated Voltage Measurement... 19:31:45 Voltage Offset Correction: v_off_ini = 660.237 uV, v_off_fin = 687.534 uV 19:31:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 108.746 uVs 19:31:45 Integrated Voltage Measurement... 19:31:54 Voltage Offset Correction: v_off_ini = 629.185 uV, v_off_fin = 645.631 uV 19:31:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -132.008 uVs 19:31:54 Integrated Voltage Measurement... 19:32:03 Voltage Offset Correction: v_off_ini = 647.307 uV, v_off_fin = 657.467 uV 19:32:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 110.169 uVs 19:32:05 I2Y Average and RMS of Measurements VT = -115.151 +- 7.145 uVs I2Y = -10.594 +- 0.657 uTm^2 19:32:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:32:20 Integrated Voltage Measurement... 19:32:29 Voltage Offset Correction: v_off_ini = 620.085 uV, v_off_fin = 624.267 uV 19:32:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.499 uVs 19:32:29 Integrated Voltage Measurement... 19:32:38 Voltage Offset Correction: v_off_ini = 625.326 uV, v_off_fin = 625.954 uV 19:32:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.095 uVs 19:32:38 Integrated Voltage Measurement... 19:32:47 Voltage Offset Correction: v_off_ini = 633.607 uV, v_off_fin = 643.682 uV 19:32:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.538 uVs 19:32:47 Integrated Voltage Measurement... 19:32:56 Voltage Offset Correction: v_off_ini = 667.472 uV, v_off_fin = 666.832 uV 19:32:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.317 uVs 19:32:56 Integrated Voltage Measurement... 19:33:05 Voltage Offset Correction: v_off_ini = 659.592 uV, v_off_fin = 648.872 uV 19:33:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.581 uVs 19:33:05 Integrated Voltage Measurement... 19:33:14 Voltage Offset Correction: v_off_ini = 652.901 uV, v_off_fin = 662.359 uV 19:33:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.223 uVs 19:33:19 I1X Average and RMS of Measurements VT = -77.542 +- 18.124 uVs I1X = 15.508 +- 3.625 uTm 19:33:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:33:25 Integrated Voltage Measurement... 19:33:34 Voltage Offset Correction: v_off_ini = 646.179 uV, v_off_fin = 649.430 uV 19:33:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.782 uVs 19:33:34 Integrated Voltage Measurement... 19:33:43 Voltage Offset Correction: v_off_ini = 652.614 uV, v_off_fin = 667.462 uV 19:33:43 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 248.412 uVs 19:33:43 Integrated Voltage Measurement... 19:33:52 Voltage Offset Correction: v_off_ini = 648.385 uV, v_off_fin = 644.694 uV 19:33:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.875 uVs 19:33:52 Integrated Voltage Measurement... 19:34:01 Voltage Offset Correction: v_off_ini = 645.452 uV, v_off_fin = 669.165 uV 19:34:01 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 243.585 uVs 19:34:01 Integrated Voltage Measurement... 19:34:10 Voltage Offset Correction: v_off_ini = 646.252 uV, v_off_fin = 648.459 uV 19:34:10 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -220.177 uVs 19:34:10 Integrated Voltage Measurement... 19:34:19 Voltage Offset Correction: v_off_ini = 653.166 uV, v_off_fin = 657.483 uV 19:34:19 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 243.936 uVs 19:34:23 I1Y Average and RMS of Measurements VT = -233.961 +- 1.371 uVs I1Y = -46.785 +- 0.276 uTm 19:34:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:34:31 Integrated Voltage Measurement... 19:34:40 Voltage Offset Correction: v_off_ini = 652.794 uV, v_off_fin = 670.878 uV 19:34:40 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -65.836 uVs 19:34:40 Integrated Voltage Measurement... 19:34:49 Voltage Offset Correction: v_off_ini = 669.816 uV, v_off_fin = 651.124 uV 19:34:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.496 uVs 19:34:49 Integrated Voltage Measurement... 19:34:58 Voltage Offset Correction: v_off_ini = 639.419 uV, v_off_fin = 657.979 uV 19:34:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.423 uVs 19:34:58 Integrated Voltage Measurement... 19:35:07 Voltage Offset Correction: v_off_ini = 661.021 uV, v_off_fin = 666.899 uV 19:35:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.241 uVs 19:35:07 Integrated Voltage Measurement... 19:35:16 Voltage Offset Correction: v_off_ini = 668.694 uV, v_off_fin = 682.469 uV 19:35:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.981 uVs 19:35:16 Integrated Voltage Measurement... 19:35:25 Voltage Offset Correction: v_off_ini = 651.882 uV, v_off_fin = 664.092 uV 19:35:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.393 uVs 19:35:28 I2X Average and RMS of Measurements VT = -64.562 +- 6.540 uVs I2X = 5.939 +- 0.602 uTm^2 19:35:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:35:35 Integrated Voltage Measurement... 19:35:44 Voltage Offset Correction: v_off_ini = 664.524 uV, v_off_fin = 647.406 uV 19:35:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -91.806 uVs 19:35:44 Integrated Voltage Measurement... 19:35:53 Voltage Offset Correction: v_off_ini = 635.558 uV, v_off_fin = 646.595 uV 19:35:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 103.747 uVs 19:35:53 Integrated Voltage Measurement... 19:36:02 Voltage Offset Correction: v_off_ini = 655.974 uV, v_off_fin = 667.770 uV 19:36:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -111.473 uVs 19:36:02 Integrated Voltage Measurement... 19:36:11 Voltage Offset Correction: v_off_ini = 670.276 uV, v_off_fin = 672.464 uV 19:36:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 105.035 uVs 19:36:11 Integrated Voltage Measurement... 19:36:20 Voltage Offset Correction: v_off_ini = 644.856 uV, v_off_fin = 650.604 uV 19:36:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -102.219 uVs 19:36:21 Integrated Voltage Measurement... 19:36:29 Voltage Offset Correction: v_off_ini = 652.597 uV, v_off_fin = 672.322 uV 19:36:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 111.959 uVs 19:36:32 I2Y Average and RMS of Measurements VT = -104.373 +- 4.689 uVs I2Y = -9.602 +- 0.431 uTm^2 19:36:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:36:47 Integrated Voltage Measurement... 19:36:56 Voltage Offset Correction: v_off_ini = 668.253 uV, v_off_fin = 650.548 uV 19:36:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.230 uVs 19:36:56 Integrated Voltage Measurement... 19:37:05 Voltage Offset Correction: v_off_ini = 678.591 uV, v_off_fin = 677.340 uV 19:37:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.686 uVs 19:37:05 Integrated Voltage Measurement... 19:37:14 Voltage Offset Correction: v_off_ini = 685.956 uV, v_off_fin = 672.230 uV 19:37:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.482 uVs 19:37:14 Integrated Voltage Measurement... 19:37:23 Voltage Offset Correction: v_off_ini = 687.383 uV, v_off_fin = 680.234 uV 19:37:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.650 uVs 19:37:23 Integrated Voltage Measurement... 19:37:32 Voltage Offset Correction: v_off_ini = 658.748 uV, v_off_fin = 668.401 uV 19:37:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.796 uVs 19:37:32 Integrated Voltage Measurement... 19:37:41 Voltage Offset Correction: v_off_ini = 673.798 uV, v_off_fin = 659.156 uV 19:37:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.298 uVs 19:37:45 I1X Average and RMS of Measurements VT = -80.690 +- 2.937 uVs I1X = 16.138 +- 0.587 uTm 19:37:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:37:52 Integrated Voltage Measurement... 19:38:01 Voltage Offset Correction: v_off_ini = 675.066 uV, v_off_fin = 650.228 uV 19:38:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.100 uVs 19:38:01 Integrated Voltage Measurement... 19:38:10 Voltage Offset Correction: v_off_ini = 665.359 uV, v_off_fin = 680.962 uV 19:38:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.585 uVs 19:38:10 Integrated Voltage Measurement... 19:38:19 Voltage Offset Correction: v_off_ini = 665.381 uV, v_off_fin = 646.097 uV 19:38:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.069 uVs 19:38:19 Integrated Voltage Measurement... 19:38:28 Voltage Offset Correction: v_off_ini = 671.544 uV, v_off_fin = 686.030 uV 19:38:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.536 uVs 19:38:28 Integrated Voltage Measurement... 19:38:37 Voltage Offset Correction: v_off_ini = 669.353 uV, v_off_fin = 660.123 uV 19:38:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.876 uVs 19:38:37 Integrated Voltage Measurement... 19:38:46 Voltage Offset Correction: v_off_ini = 666.564 uV, v_off_fin = 673.458 uV 19:38:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.128 uVs 19:38:50 I1Y Average and RMS of Measurements VT = -231.716 +- 1.509 uVs I1Y = -46.343 +- 0.302 uTm 19:38:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:38:58 Integrated Voltage Measurement... 19:39:07 Voltage Offset Correction: v_off_ini = 654.247 uV, v_off_fin = 686.795 uV 19:39:07 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -65.729 uVs 19:39:07 Integrated Voltage Measurement... 19:39:16 Voltage Offset Correction: v_off_ini = 688.594 uV, v_off_fin = 672.603 uV 19:39:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.425 uVs 19:39:16 Integrated Voltage Measurement... 19:39:25 Voltage Offset Correction: v_off_ini = 670.199 uV, v_off_fin = 677.532 uV 19:39:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.680 uVs 19:39:25 Integrated Voltage Measurement... 19:39:34 Voltage Offset Correction: v_off_ini = 659.890 uV, v_off_fin = 670.844 uV 19:39:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.210 uVs 19:39:34 Integrated Voltage Measurement... 19:39:43 Voltage Offset Correction: v_off_ini = 666.990 uV, v_off_fin = 689.998 uV 19:39:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.906 uVs 19:39:43 Integrated Voltage Measurement... 19:39:52 Voltage Offset Correction: v_off_ini = 671.356 uV, v_off_fin = 671.814 uV 19:39:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.390 uVs 19:39:55 I2X Average and RMS of Measurements VT = -73.224 +- 7.887 uVs I2X = 6.737 +- 0.726 uTm^2 19:40:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:40:02 Integrated Voltage Measurement... 19:40:11 Voltage Offset Correction: v_off_ini = 675.803 uV, v_off_fin = 684.005 uV 19:40:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -93.518 uVs 19:40:11 Integrated Voltage Measurement... 19:40:20 Voltage Offset Correction: v_off_ini = 693.633 uV, v_off_fin = 693.004 uV 19:40:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 91.436 uVs 19:40:20 Integrated Voltage Measurement... 19:40:29 Voltage Offset Correction: v_off_ini = 671.149 uV, v_off_fin = 662.507 uV 19:40:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -108.486 uVs 19:40:29 Integrated Voltage Measurement... 19:40:38 Voltage Offset Correction: v_off_ini = 650.885 uV, v_off_fin = 673.427 uV 19:40:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 124.576 uVs 19:40:38 Integrated Voltage Measurement... 19:40:47 Voltage Offset Correction: v_off_ini = 675.779 uV, v_off_fin = 690.056 uV 19:40:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -110.245 uVs 19:40:48 Integrated Voltage Measurement... 19:40:57 Voltage Offset Correction: v_off_ini = 705.895 uV, v_off_fin = 691.243 uV 19:40:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 102.731 uVs 19:40:59 I2Y Average and RMS of Measurements VT = -105.165 +- 9.864 uVs I2Y = -9.675 +- 0.908 uTm^2 19:41:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:41:14 Integrated Voltage Measurement... 19:41:23 Voltage Offset Correction: v_off_ini = 680.619 uV, v_off_fin = 673.904 uV 19:41:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.634 uVs 19:41:23 Integrated Voltage Measurement... 19:41:32 Voltage Offset Correction: v_off_ini = 691.296 uV, v_off_fin = 684.189 uV 19:41:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.729 uVs 19:41:32 Integrated Voltage Measurement... 19:41:41 Voltage Offset Correction: v_off_ini = 682.558 uV, v_off_fin = 684.410 uV 19:41:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.986 uVs 19:41:41 Integrated Voltage Measurement... 19:41:50 Voltage Offset Correction: v_off_ini = 664.262 uV, v_off_fin = 662.609 uV 19:41:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.816 uVs 19:41:50 Integrated Voltage Measurement... 19:41:59 Voltage Offset Correction: v_off_ini = 662.522 uV, v_off_fin = 655.311 uV 19:41:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.252 uVs 19:41:59 Integrated Voltage Measurement... 19:42:08 Voltage Offset Correction: v_off_ini = 668.210 uV, v_off_fin = 684.357 uV 19:42:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.460 uVs 19:42:12 I1X Average and RMS of Measurements VT = -86.813 +- 5.511 uVs I1X = 17.363 +- 1.102 uTm 19:42:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:42:19 Integrated Voltage Measurement... 19:42:28 Voltage Offset Correction: v_off_ini = 673.927 uV, v_off_fin = 661.479 uV 19:42:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.164 uVs 19:42:28 Integrated Voltage Measurement... 19:42:37 Voltage Offset Correction: v_off_ini = 673.281 uV, v_off_fin = 668.318 uV 19:42:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.725 uVs 19:42:37 Integrated Voltage Measurement... 19:42:46 Voltage Offset Correction: v_off_ini = 631.173 uV, v_off_fin = 655.596 uV 19:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.762 uVs 19:42:46 Integrated Voltage Measurement... 19:42:55 Voltage Offset Correction: v_off_ini = 670.132 uV, v_off_fin = 679.533 uV 19:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.049 uVs 19:42:55 Integrated Voltage Measurement... 19:43:04 Voltage Offset Correction: v_off_ini = 673.864 uV, v_off_fin = 660.106 uV 19:43:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.222 uVs 19:43:04 Integrated Voltage Measurement... 19:43:13 Voltage Offset Correction: v_off_ini = 675.255 uV, v_off_fin = 683.335 uV 19:43:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.517 uVs 19:43:17 I1Y Average and RMS of Measurements VT = -220.740 +- 10.226 uVs I1Y = -44.148 +- 2.045 uTm 19:43:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:43:25 Integrated Voltage Measurement... 19:43:34 Voltage Offset Correction: v_off_ini = 661.902 uV, v_off_fin = 682.498 uV 19:43:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.213 uVs 19:43:34 Integrated Voltage Measurement... 19:43:43 Voltage Offset Correction: v_off_ini = 689.767 uV, v_off_fin = 669.850 uV 19:43:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.849 uVs 19:43:43 Integrated Voltage Measurement... 19:43:52 Voltage Offset Correction: v_off_ini = 663.121 uV, v_off_fin = 676.204 uV 19:43:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.352 uVs 19:43:52 Integrated Voltage Measurement... 19:44:01 Voltage Offset Correction: v_off_ini = 662.933 uV, v_off_fin = 671.198 uV 19:44:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.182 uVs 19:44:01 Integrated Voltage Measurement... 19:44:10 Voltage Offset Correction: v_off_ini = 669.401 uV, v_off_fin = 651.769 uV 19:44:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -75.038 uVs 19:44:10 Integrated Voltage Measurement... 19:44:19 Voltage Offset Correction: v_off_ini = 660.638 uV, v_off_fin = 646.482 uV 19:44:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.623 uVs 19:44:22 I2X Average and RMS of Measurements VT = -86.043 +- 8.650 uVs I2X = 7.916 +- 0.796 uTm^2 19:44:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:44:29 Integrated Voltage Measurement... 19:44:38 Voltage Offset Correction: v_off_ini = 666.216 uV, v_off_fin = 662.098 uV 19:44:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -107.802 uVs 19:44:38 Integrated Voltage Measurement... 19:44:47 Voltage Offset Correction: v_off_ini = 656.255 uV, v_off_fin = 662.622 uV 19:44:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 109.235 uVs 19:44:47 Integrated Voltage Measurement... 19:44:56 Voltage Offset Correction: v_off_ini = 669.593 uV, v_off_fin = 653.001 uV 19:44:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -124.520 uVs 19:44:56 Integrated Voltage Measurement... 19:45:05 Voltage Offset Correction: v_off_ini = 661.188 uV, v_off_fin = 659.439 uV 19:45:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 118.737 uVs 19:45:06 Integrated Voltage Measurement... 19:45:15 Voltage Offset Correction: v_off_ini = 659.764 uV, v_off_fin = 660.656 uV 19:45:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -109.885 uVs 19:45:15 Integrated Voltage Measurement... 19:45:24 Voltage Offset Correction: v_off_ini = 677.769 uV, v_off_fin = 680.714 uV 19:45:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 90.484 uVs 19:45:26 I2Y Average and RMS of Measurements VT = -110.111 +- 8.826 uVs I2Y = -10.130 +- 0.812 uTm^2 19:45:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:45:41 Integrated Voltage Measurement... 19:45:50 Voltage Offset Correction: v_off_ini = 645.724 uV, v_off_fin = 647.706 uV 19:45:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.441 uVs 19:45:50 Integrated Voltage Measurement... 19:45:59 Voltage Offset Correction: v_off_ini = 656.284 uV, v_off_fin = 667.938 uV 19:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.589 uVs 19:45:59 Integrated Voltage Measurement... 19:46:08 Voltage Offset Correction: v_off_ini = 656.040 uV, v_off_fin = 662.686 uV 19:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.440 uVs 19:46:08 Integrated Voltage Measurement... 19:46:17 Voltage Offset Correction: v_off_ini = 668.589 uV, v_off_fin = 664.390 uV 19:46:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.434 uVs 19:46:17 Integrated Voltage Measurement... 19:46:26 Voltage Offset Correction: v_off_ini = 646.633 uV, v_off_fin = 636.364 uV 19:46:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.352 uVs 19:46:26 Integrated Voltage Measurement... 19:46:35 Voltage Offset Correction: v_off_ini = 668.588 uV, v_off_fin = 665.455 uV 19:46:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.339 uVs 19:46:39 I1X Average and RMS of Measurements VT = -96.933 +- 7.130 uVs I1X = 19.387 +- 1.426 uTm 19:46:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:46:46 Integrated Voltage Measurement... 19:46:55 Voltage Offset Correction: v_off_ini = 678.937 uV, v_off_fin = 665.173 uV 19:46:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.865 uVs 19:46:55 Integrated Voltage Measurement... 19:47:04 Voltage Offset Correction: v_off_ini = 671.900 uV, v_off_fin = 684.014 uV 19:47:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.077 uVs 19:47:04 Integrated Voltage Measurement... 19:47:13 Voltage Offset Correction: v_off_ini = 658.011 uV, v_off_fin = 658.326 uV 19:47:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.182 uVs 19:47:13 Integrated Voltage Measurement... 19:47:22 Voltage Offset Correction: v_off_ini = 674.997 uV, v_off_fin = 683.778 uV 19:47:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.086 uVs 19:47:22 Integrated Voltage Measurement... 19:47:31 Voltage Offset Correction: v_off_ini = 653.064 uV, v_off_fin = 649.353 uV 19:47:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.203 uVs 19:47:31 Integrated Voltage Measurement... 19:47:40 Voltage Offset Correction: v_off_ini = 660.031 uV, v_off_fin = 691.748 uV 19:47:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.620 uVs 19:47:44 I1Y Average and RMS of Measurements VT = -213.172 +- 4.479 uVs I1Y = -42.634 +- 0.896 uTm 19:47:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:47:52 Integrated Voltage Measurement... 19:48:01 Voltage Offset Correction: v_off_ini = 671.312 uV, v_off_fin = 681.135 uV 19:48:01 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -124.608 uVs 19:48:01 Integrated Voltage Measurement... 19:48:10 Voltage Offset Correction: v_off_ini = 679.375 uV, v_off_fin = 679.779 uV 19:48:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.362 uVs 19:48:10 Integrated Voltage Measurement... 19:48:19 Voltage Offset Correction: v_off_ini = 665.728 uV, v_off_fin = 663.732 uV 19:48:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.072 uVs 19:48:19 Integrated Voltage Measurement... 19:48:28 Voltage Offset Correction: v_off_ini = 644.597 uV, v_off_fin = 632.428 uV 19:48:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.657 uVs 19:48:28 Integrated Voltage Measurement... 19:48:37 Voltage Offset Correction: v_off_ini = 650.056 uV, v_off_fin = 643.102 uV 19:48:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -109.053 uVs 19:48:37 Integrated Voltage Measurement... 19:48:46 Voltage Offset Correction: v_off_ini = 653.872 uV, v_off_fin = 636.450 uV 19:48:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.466 uVs 19:48:49 I2X Average and RMS of Measurements VT = -100.369 +- 5.975 uVs I2X = 9.234 +- 0.549 uTm^2 19:48:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:48:56 Integrated Voltage Measurement... 19:49:05 Voltage Offset Correction: v_off_ini = 665.509 uV, v_off_fin = 643.798 uV 19:49:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -104.763 uVs 19:49:05 Integrated Voltage Measurement... 19:49:14 Voltage Offset Correction: v_off_ini = 649.554 uV, v_off_fin = 645.663 uV 19:49:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 117.564 uVs 19:49:14 Integrated Voltage Measurement... 19:49:23 Voltage Offset Correction: v_off_ini = 643.171 uV, v_off_fin = 633.928 uV 19:49:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -104.741 uVs 19:49:23 Integrated Voltage Measurement... 19:49:32 Voltage Offset Correction: v_off_ini = 638.494 uV, v_off_fin = 659.266 uV 19:49:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 106.634 uVs 19:49:32 Integrated Voltage Measurement... 19:49:41 Voltage Offset Correction: v_off_ini = 642.063 uV, v_off_fin = 653.975 uV 19:49:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -120.708 uVs 19:49:42 Integrated Voltage Measurement... 19:49:51 Voltage Offset Correction: v_off_ini = 643.564 uV, v_off_fin = 648.853 uV 19:49:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 116.690 uVs 19:49:53 I2Y Average and RMS of Measurements VT = -111.850 +- 5.334 uVs I2Y = -10.290 +- 0.491 uTm^2 19:50:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:50:08 Integrated Voltage Measurement... 19:50:17 Voltage Offset Correction: v_off_ini = 631.822 uV, v_off_fin = 626.976 uV 19:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.110 uVs 19:50:17 Integrated Voltage Measurement... 19:50:26 Voltage Offset Correction: v_off_ini = 631.393 uV, v_off_fin = 631.019 uV 19:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.872 uVs 19:50:26 Integrated Voltage Measurement... 19:50:35 Voltage Offset Correction: v_off_ini = 641.372 uV, v_off_fin = 653.344 uV 19:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.820 uVs 19:50:35 Integrated Voltage Measurement... 19:50:44 Voltage Offset Correction: v_off_ini = 652.109 uV, v_off_fin = 644.561 uV 19:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.093 uVs 19:50:44 Integrated Voltage Measurement... 19:50:53 Voltage Offset Correction: v_off_ini = 644.474 uV, v_off_fin = 655.287 uV 19:50:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.959 uVs 19:50:53 Integrated Voltage Measurement... 19:51:02 Voltage Offset Correction: v_off_ini = 648.745 uV, v_off_fin = 652.179 uV 19:51:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.215 uVs 19:51:06 I1X Average and RMS of Measurements VT = -103.178 +- 8.903 uVs I1X = 20.636 +- 1.781 uTm 19:51:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:51:13 Integrated Voltage Measurement... 19:51:22 Voltage Offset Correction: v_off_ini = 668.284 uV, v_off_fin = 656.051 uV 19:51:22 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.168 uVs 19:51:22 Integrated Voltage Measurement... 19:51:31 Voltage Offset Correction: v_off_ini = 687.373 uV, v_off_fin = 683.148 uV 19:51:31 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 198.464 uVs 19:51:31 Integrated Voltage Measurement... 19:51:40 Voltage Offset Correction: v_off_ini = 666.642 uV, v_off_fin = 650.647 uV 19:51:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.269 uVs 19:51:40 Integrated Voltage Measurement... 19:51:49 Voltage Offset Correction: v_off_ini = 669.997 uV, v_off_fin = 688.977 uV 19:51:49 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 194.984 uVs 19:51:49 Integrated Voltage Measurement... 19:51:58 Voltage Offset Correction: v_off_ini = 685.960 uV, v_off_fin = 651.695 uV 19:51:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.338 uVs 19:51:58 Integrated Voltage Measurement... 19:52:07 Voltage Offset Correction: v_off_ini = 658.343 uV, v_off_fin = 655.866 uV 19:52:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.561 uVs 19:52:11 I1Y Average and RMS of Measurements VT = -207.797 +- 4.583 uVs I1Y = -41.555 +- 0.918 uTm 19:52:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:52:19 Integrated Voltage Measurement... 19:52:28 Voltage Offset Correction: v_off_ini = 660.148 uV, v_off_fin = 676.675 uV 19:52:28 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -89.522 uVs 19:52:28 Integrated Voltage Measurement... 19:52:37 Voltage Offset Correction: v_off_ini = 647.253 uV, v_off_fin = 664.202 uV 19:52:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.604 uVs 19:52:37 Integrated Voltage Measurement... 19:52:46 Voltage Offset Correction: v_off_ini = 680.278 uV, v_off_fin = 669.970 uV 19:52:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.584 uVs 19:52:46 Integrated Voltage Measurement... 19:52:55 Voltage Offset Correction: v_off_ini = 646.070 uV, v_off_fin = 645.789 uV 19:52:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.960 uVs 19:52:55 Integrated Voltage Measurement... 19:53:04 Voltage Offset Correction: v_off_ini = 677.503 uV, v_off_fin = 671.195 uV 19:53:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.442 uVs 19:53:04 Integrated Voltage Measurement... 19:53:13 Voltage Offset Correction: v_off_ini = 658.097 uV, v_off_fin = 671.248 uV 19:53:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.176 uVs 19:53:16 I2X Average and RMS of Measurements VT = -89.381 +- 9.891 uVs I2X = 8.223 +- 0.910 uTm^2 19:53:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:53:23 Integrated Voltage Measurement... 19:53:32 Voltage Offset Correction: v_off_ini = 647.322 uV, v_off_fin = 670.753 uV 19:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -112.959 uVs 19:53:32 Integrated Voltage Measurement... 19:53:41 Voltage Offset Correction: v_off_ini = 656.805 uV, v_off_fin = 654.320 uV 19:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 95.298 uVs 19:53:41 Integrated Voltage Measurement... 19:53:50 Voltage Offset Correction: v_off_ini = 652.670 uV, v_off_fin = 653.900 uV 19:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -112.560 uVs 19:53:50 Integrated Voltage Measurement... 19:53:59 Voltage Offset Correction: v_off_ini = 659.401 uV, v_off_fin = 667.826 uV 19:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 118.451 uVs 19:53:59 Integrated Voltage Measurement... 19:54:08 Voltage Offset Correction: v_off_ini = 642.429 uV, v_off_fin = 641.208 uV 19:54:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -116.523 uVs 19:54:09 Integrated Voltage Measurement... 19:54:17 Voltage Offset Correction: v_off_ini = 671.744 uV, v_off_fin = 681.532 uV 19:54:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 86.422 uVs 19:54:20 I2Y Average and RMS of Measurements VT = -107.036 +- 6.086 uVs I2Y = -9.847 +- 0.560 uTm^2 19:54:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:54:35 Integrated Voltage Measurement... 19:54:44 Voltage Offset Correction: v_off_ini = 657.265 uV, v_off_fin = 646.995 uV 19:54:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.380 uVs 19:54:44 Integrated Voltage Measurement... 19:54:53 Voltage Offset Correction: v_off_ini = 638.117 uV, v_off_fin = 650.842 uV 19:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.852 uVs 19:54:53 Integrated Voltage Measurement... 19:55:02 Voltage Offset Correction: v_off_ini = 647.149 uV, v_off_fin = 642.931 uV 19:55:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.951 uVs 19:55:02 Integrated Voltage Measurement... 19:55:11 Voltage Offset Correction: v_off_ini = 596.959 uV, v_off_fin = 605.627 uV 19:55:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.740 uVs 19:55:11 Integrated Voltage Measurement... 19:55:20 Voltage Offset Correction: v_off_ini = 620.370 uV, v_off_fin = 643.431 uV 19:55:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.278 uVs 19:55:20 Integrated Voltage Measurement... 19:55:29 Voltage Offset Correction: v_off_ini = 661.529 uV, v_off_fin = 654.453 uV 19:55:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.446 uVs 19:55:33 I1X Average and RMS of Measurements VT = -110.108 +- 15.793 uVs I1X = 22.022 +- 3.159 uTm 19:55:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:55:40 Integrated Voltage Measurement... 19:55:49 Voltage Offset Correction: v_off_ini = 655.679 uV, v_off_fin = 644.600 uV 19:55:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.459 uVs 19:55:49 Integrated Voltage Measurement... 19:55:58 Voltage Offset Correction: v_off_ini = 633.306 uV, v_off_fin = 654.610 uV 19:55:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.100 uVs 19:55:58 Integrated Voltage Measurement... 19:56:07 Voltage Offset Correction: v_off_ini = 636.342 uV, v_off_fin = 622.487 uV 19:56:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.100 uVs 19:56:07 Integrated Voltage Measurement... 19:56:16 Voltage Offset Correction: v_off_ini = 637.559 uV, v_off_fin = 654.218 uV 19:56:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.772 uVs 19:56:16 Integrated Voltage Measurement... 19:56:25 Voltage Offset Correction: v_off_ini = 652.067 uV, v_off_fin = 652.601 uV 19:56:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.263 uVs 19:56:25 Integrated Voltage Measurement... 19:56:34 Voltage Offset Correction: v_off_ini = 637.398 uV, v_off_fin = 641.140 uV 19:56:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.182 uVs 19:56:38 I1Y Average and RMS of Measurements VT = -211.646 +- 6.460 uVs I1Y = -42.329 +- 1.292 uTm 19:56:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:56:46 Integrated Voltage Measurement... 19:56:55 Voltage Offset Correction: v_off_ini = 638.396 uV, v_off_fin = 627.632 uV 19:56:55 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -110.357 uVs 19:56:55 Integrated Voltage Measurement... 19:57:04 Voltage Offset Correction: v_off_ini = 636.997 uV, v_off_fin = 637.870 uV 19:57:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.358 uVs 19:57:04 Integrated Voltage Measurement... 19:57:13 Voltage Offset Correction: v_off_ini = 635.061 uV, v_off_fin = 651.750 uV 19:57:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.558 uVs 19:57:13 Integrated Voltage Measurement... 19:57:22 Voltage Offset Correction: v_off_ini = 632.199 uV, v_off_fin = 639.034 uV 19:57:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.313 uVs 19:57:22 Integrated Voltage Measurement... 19:57:31 Voltage Offset Correction: v_off_ini = 648.237 uV, v_off_fin = 656.202 uV 19:57:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.832 uVs 19:57:31 Integrated Voltage Measurement... 19:57:40 Voltage Offset Correction: v_off_ini = 659.328 uV, v_off_fin = 635.058 uV 19:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.815 uVs 19:57:43 I2X Average and RMS of Measurements VT = -100.539 +- 2.099 uVs I2X = 9.249 +- 0.193 uTm^2 19:57:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:57:50 Integrated Voltage Measurement... 19:57:59 Voltage Offset Correction: v_off_ini = 627.078 uV, v_off_fin = 634.619 uV 19:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -99.977 uVs 19:57:59 Integrated Voltage Measurement... 19:58:08 Voltage Offset Correction: v_off_ini = 627.899 uV, v_off_fin = 624.008 uV 19:58:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 95.897 uVs 19:58:08 Integrated Voltage Measurement... 19:58:17 Voltage Offset Correction: v_off_ini = 638.673 uV, v_off_fin = 621.597 uV 19:58:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -106.902 uVs 19:58:17 Integrated Voltage Measurement... 19:58:26 Voltage Offset Correction: v_off_ini = 619.555 uV, v_off_fin = 621.379 uV 19:58:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 122.574 uVs 19:58:26 Integrated Voltage Measurement... 19:58:35 Voltage Offset Correction: v_off_ini = 644.933 uV, v_off_fin = 630.055 uV 19:58:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -121.661 uVs 19:58:35 Integrated Voltage Measurement... 19:58:44 Voltage Offset Correction: v_off_ini = 645.970 uV, v_off_fin = 647.432 uV 19:58:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 91.683 uVs 19:58:47 I2Y Average and RMS of Measurements VT = -106.449 +- 6.861 uVs I2Y = -9.793 +- 0.631 uTm^2 19:58:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:59:02 Integrated Voltage Measurement... 19:59:11 Voltage Offset Correction: v_off_ini = 640.445 uV, v_off_fin = 643.423 uV 19:59:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.604 uVs 19:59:11 Integrated Voltage Measurement... 19:59:20 Voltage Offset Correction: v_off_ini = 633.400 uV, v_off_fin = 646.310 uV 19:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.755 uVs 19:59:20 Integrated Voltage Measurement... 19:59:29 Voltage Offset Correction: v_off_ini = 620.786 uV, v_off_fin = 619.533 uV 19:59:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.966 uVs 19:59:29 Integrated Voltage Measurement... 19:59:38 Voltage Offset Correction: v_off_ini = 641.563 uV, v_off_fin = 633.292 uV 19:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.085 uVs 19:59:38 Integrated Voltage Measurement... 19:59:47 Voltage Offset Correction: v_off_ini = 631.637 uV, v_off_fin = 630.882 uV 19:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.069 uVs 19:59:47 Integrated Voltage Measurement... 19:59:56 Voltage Offset Correction: v_off_ini = 639.282 uV, v_off_fin = 637.575 uV 19:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.129 uVs 20:00:00 I1X Average and RMS of Measurements VT = -107.768 +- 9.939 uVs I1X = 21.554 +- 1.988 uTm 20:00:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:00:07 Integrated Voltage Measurement... 20:00:16 Voltage Offset Correction: v_off_ini = 632.497 uV, v_off_fin = 631.422 uV 20:00:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.751 uVs 20:00:16 Integrated Voltage Measurement... 20:00:25 Voltage Offset Correction: v_off_ini = 628.999 uV, v_off_fin = 649.313 uV 20:00:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.174 uVs 20:00:25 Integrated Voltage Measurement... 20:00:34 Voltage Offset Correction: v_off_ini = 632.929 uV, v_off_fin = 620.039 uV 20:00:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -196.763 uVs 20:00:34 Integrated Voltage Measurement... 20:00:43 Voltage Offset Correction: v_off_ini = 617.914 uV, v_off_fin = 623.047 uV 20:00:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.847 uVs 20:00:43 Integrated Voltage Measurement... 20:00:52 Voltage Offset Correction: v_off_ini = 624.282 uV, v_off_fin = 625.287 uV 20:00:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.660 uVs 20:00:52 Integrated Voltage Measurement... 20:01:01 Voltage Offset Correction: v_off_ini = 621.111 uV, v_off_fin = 649.532 uV 20:01:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 207.061 uVs 20:01:05 I1Y Average and RMS of Measurements VT = -206.209 +- 10.966 uVs I1Y = -41.245 +- 2.193 uTm 20:01:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:01:13 Integrated Voltage Measurement... 20:01:22 Voltage Offset Correction: v_off_ini = 663.093 uV, v_off_fin = 669.089 uV 20:01:22 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.198 uVs 20:01:22 Integrated Voltage Measurement... 20:01:31 Voltage Offset Correction: v_off_ini = 651.498 uV, v_off_fin = 642.991 uV 20:01:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.033 uVs 20:01:31 Integrated Voltage Measurement... 20:01:40 Voltage Offset Correction: v_off_ini = 673.901 uV, v_off_fin = 661.808 uV 20:01:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.886 uVs 20:01:40 Integrated Voltage Measurement... 20:01:49 Voltage Offset Correction: v_off_ini = 665.378 uV, v_off_fin = 656.594 uV 20:01:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.079 uVs 20:01:49 Integrated Voltage Measurement... 20:01:58 Voltage Offset Correction: v_off_ini = 662.628 uV, v_off_fin = 651.069 uV 20:01:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.339 uVs 20:01:58 Integrated Voltage Measurement... 20:02:07 Voltage Offset Correction: v_off_ini = 663.810 uV, v_off_fin = 662.569 uV 20:02:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.216 uVs 20:02:10 I2X Average and RMS of Measurements VT = -110.292 +- 9.750 uVs I2X = 10.147 +- 0.897 uTm^2 20:02:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:02:17 Integrated Voltage Measurement... 20:02:26 Voltage Offset Correction: v_off_ini = 634.130 uV, v_off_fin = 639.568 uV 20:02:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -90.187 uVs 20:02:26 Integrated Voltage Measurement... 20:02:35 Voltage Offset Correction: v_off_ini = 650.692 uV, v_off_fin = 649.240 uV 20:02:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 117.030 uVs 20:02:35 Integrated Voltage Measurement... 20:02:44 Voltage Offset Correction: v_off_ini = 655.106 uV, v_off_fin = 656.239 uV 20:02:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -108.099 uVs 20:02:44 Integrated Voltage Measurement... 20:02:53 Voltage Offset Correction: v_off_ini = 644.356 uV, v_off_fin = 654.194 uV 20:02:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 122.108 uVs 20:02:53 Integrated Voltage Measurement... 20:03:02 Voltage Offset Correction: v_off_ini = 640.590 uV, v_off_fin = 621.119 uV 20:03:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -89.009 uVs 20:03:02 Integrated Voltage Measurement... 20:03:11 Voltage Offset Correction: v_off_ini = 638.285 uV, v_off_fin = 636.774 uV 20:03:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 123.377 uVs 20:03:14 I2Y Average and RMS of Measurements VT = -108.302 +- 4.924 uVs I2Y = -9.964 +- 0.453 uTm^2 20:03:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:03:29 Integrated Voltage Measurement... 20:03:38 Voltage Offset Correction: v_off_ini = 629.018 uV, v_off_fin = 630.854 uV 20:03:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.820 uVs 20:03:38 Integrated Voltage Measurement... 20:03:47 Voltage Offset Correction: v_off_ini = 631.624 uV, v_off_fin = 649.821 uV 20:03:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.377 uVs 20:03:47 Integrated Voltage Measurement... 20:03:56 Voltage Offset Correction: v_off_ini = 626.270 uV, v_off_fin = 606.502 uV 20:03:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.487 uVs 20:03:56 Integrated Voltage Measurement... 20:04:05 Voltage Offset Correction: v_off_ini = 626.911 uV, v_off_fin = 618.982 uV 20:04:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.194 uVs 20:04:05 Integrated Voltage Measurement... 20:04:14 Voltage Offset Correction: v_off_ini = 620.417 uV, v_off_fin = 623.871 uV 20:04:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.964 uVs 20:04:14 Integrated Voltage Measurement... 20:04:23 Voltage Offset Correction: v_off_ini = 633.984 uV, v_off_fin = 638.789 uV 20:04:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.785 uVs 20:04:27 I1X Average and RMS of Measurements VT = -120.438 +- 7.384 uVs I1X = 24.088 +- 1.477 uTm 20:04:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:04:34 Integrated Voltage Measurement... 20:04:43 Voltage Offset Correction: v_off_ini = 608.958 uV, v_off_fin = 624.146 uV 20:04:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.512 uVs 20:04:43 Integrated Voltage Measurement... 20:04:52 Voltage Offset Correction: v_off_ini = 642.328 uV, v_off_fin = 646.636 uV 20:04:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.494 uVs 20:04:52 Integrated Voltage Measurement... 20:05:01 Voltage Offset Correction: v_off_ini = 624.492 uV, v_off_fin = 619.153 uV 20:05:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.570 uVs 20:05:01 Integrated Voltage Measurement... 20:05:10 Voltage Offset Correction: v_off_ini = 634.079 uV, v_off_fin = 637.051 uV 20:05:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.079 uVs 20:05:10 Integrated Voltage Measurement... 20:05:19 Voltage Offset Correction: v_off_ini = 627.194 uV, v_off_fin = 591.927 uV 20:05:19 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -200.167 uVs 20:05:19 Integrated Voltage Measurement... 20:05:28 Voltage Offset Correction: v_off_ini = 614.583 uV, v_off_fin = 620.581 uV 20:05:28 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 215.622 uVs 20:05:32 I1Y Average and RMS of Measurements VT = -213.407 +- 4.279 uVs I1Y = -42.678 +- 0.860 uTm 20:05:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:05:40 Integrated Voltage Measurement... 20:05:49 Voltage Offset Correction: v_off_ini = 631.854 uV, v_off_fin = 650.534 uV 20:05:49 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -128.519 uVs 20:05:49 Integrated Voltage Measurement... 20:05:58 Voltage Offset Correction: v_off_ini = 636.073 uV, v_off_fin = 628.799 uV 20:05:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.747 uVs 20:05:58 Integrated Voltage Measurement... 20:06:07 Voltage Offset Correction: v_off_ini = 628.308 uV, v_off_fin = 618.561 uV 20:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.039 uVs 20:06:07 Integrated Voltage Measurement... 20:06:16 Voltage Offset Correction: v_off_ini = 616.432 uV, v_off_fin = 615.843 uV 20:06:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.940 uVs 20:06:16 Integrated Voltage Measurement... 20:06:25 Voltage Offset Correction: v_off_ini = 620.911 uV, v_off_fin = 626.578 uV 20:06:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.169 uVs 20:06:25 Integrated Voltage Measurement... 20:06:34 Voltage Offset Correction: v_off_ini = 617.443 uV, v_off_fin = 625.978 uV 20:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.911 uVs 20:06:36 I2X Average and RMS of Measurements VT = -119.387 +- 3.364 uVs I2X = 10.984 +- 0.310 uTm^2 20:06:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:06:44 Integrated Voltage Measurement... 20:06:53 Voltage Offset Correction: v_off_ini = 617.158 uV, v_off_fin = 609.388 uV 20:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -111.496 uVs 20:06:53 Integrated Voltage Measurement... 20:07:02 Voltage Offset Correction: v_off_ini = 606.676 uV, v_off_fin = 622.577 uV 20:07:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 104.670 uVs 20:07:02 Integrated Voltage Measurement... 20:07:11 Voltage Offset Correction: v_off_ini = 626.464 uV, v_off_fin = 618.904 uV 20:07:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -108.523 uVs 20:07:11 Integrated Voltage Measurement... 20:07:20 Voltage Offset Correction: v_off_ini = 610.724 uV, v_off_fin = 608.336 uV 20:07:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 109.483 uVs 20:07:20 Integrated Voltage Measurement... 20:07:29 Voltage Offset Correction: v_off_ini = 608.482 uV, v_off_fin = 591.332 uV 20:07:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -102.683 uVs 20:07:29 Integrated Voltage Measurement... 20:07:38 Voltage Offset Correction: v_off_ini = 611.251 uV, v_off_fin = 620.761 uV 20:07:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 118.111 uVs 20:07:41 I2Y Average and RMS of Measurements VT = -109.161 +- 0.951 uVs I2Y = -10.043 +- 0.088 uTm^2 20:07:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:07:56 Integrated Voltage Measurement... 20:08:05 Voltage Offset Correction: v_off_ini = 593.834 uV, v_off_fin = 597.805 uV 20:08:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.762 uVs 20:08:05 Integrated Voltage Measurement... 20:08:14 Voltage Offset Correction: v_off_ini = 614.914 uV, v_off_fin = 614.443 uV 20:08:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.791 uVs 20:08:14 Integrated Voltage Measurement... 20:08:23 Voltage Offset Correction: v_off_ini = 603.355 uV, v_off_fin = 602.815 uV 20:08:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.129 uVs 20:08:23 Integrated Voltage Measurement... 20:08:32 Voltage Offset Correction: v_off_ini = 617.609 uV, v_off_fin = 613.907 uV 20:08:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.670 uVs 20:08:32 Integrated Voltage Measurement... 20:08:41 Voltage Offset Correction: v_off_ini = 625.118 uV, v_off_fin = 601.152 uV 20:08:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.806 uVs 20:08:41 Integrated Voltage Measurement... 20:08:50 Voltage Offset Correction: v_off_ini = 600.538 uV, v_off_fin = 612.012 uV 20:08:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.483 uVs 20:08:54 I1X Average and RMS of Measurements VT = -128.607 +- 10.483 uVs I1X = 25.721 +- 2.097 uTm 20:08:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:09:01 Integrated Voltage Measurement... 20:09:10 Voltage Offset Correction: v_off_ini = 625.498 uV, v_off_fin = 623.440 uV 20:09:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.554 uVs 20:09:10 Integrated Voltage Measurement... 20:09:19 Voltage Offset Correction: v_off_ini = 620.252 uV, v_off_fin = 619.236 uV 20:09:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.364 uVs 20:09:19 Integrated Voltage Measurement... 20:09:28 Voltage Offset Correction: v_off_ini = 607.013 uV, v_off_fin = 605.247 uV 20:09:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.175 uVs 20:09:28 Integrated Voltage Measurement... 20:09:37 Voltage Offset Correction: v_off_ini = 619.922 uV, v_off_fin = 634.042 uV 20:09:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.292 uVs 20:09:37 Integrated Voltage Measurement... 20:09:46 Voltage Offset Correction: v_off_ini = 621.188 uV, v_off_fin = 610.862 uV 20:09:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.755 uVs 20:09:46 Integrated Voltage Measurement... 20:09:55 Voltage Offset Correction: v_off_ini = 632.524 uV, v_off_fin = 625.995 uV 20:09:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.296 uVs 20:09:59 I1Y Average and RMS of Measurements VT = -204.239 +- 10.763 uVs I1Y = -40.848 +- 2.153 uTm 20:10:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:10:07 Integrated Voltage Measurement... 20:10:16 Voltage Offset Correction: v_off_ini = 599.794 uV, v_off_fin = 620.548 uV 20:10:16 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -116.992 uVs 20:10:16 Integrated Voltage Measurement... 20:10:25 Voltage Offset Correction: v_off_ini = 580.435 uV, v_off_fin = 582.097 uV 20:10:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.751 uVs 20:10:25 Integrated Voltage Measurement... 20:10:34 Voltage Offset Correction: v_off_ini = 599.032 uV, v_off_fin = 592.562 uV 20:10:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.536 uVs 20:10:34 Integrated Voltage Measurement... 20:10:43 Voltage Offset Correction: v_off_ini = 594.029 uV, v_off_fin = 596.593 uV 20:10:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.104 uVs 20:10:43 Integrated Voltage Measurement... 20:10:52 Voltage Offset Correction: v_off_ini = 605.430 uV, v_off_fin = 623.436 uV 20:10:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.485 uVs 20:10:52 Integrated Voltage Measurement... 20:11:01 Voltage Offset Correction: v_off_ini = 616.470 uV, v_off_fin = 591.759 uV 20:11:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.326 uVs 20:11:03 I2X Average and RMS of Measurements VT = -114.366 +- 1.749 uVs I2X = 10.521 +- 0.161 uTm^2 20:11:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:11:11 Integrated Voltage Measurement... 20:11:20 Voltage Offset Correction: v_off_ini = 614.707 uV, v_off_fin = 624.545 uV 20:11:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -126.242 uVs 20:11:20 Integrated Voltage Measurement... 20:11:29 Voltage Offset Correction: v_off_ini = 614.834 uV, v_off_fin = 626.944 uV 20:11:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 109.221 uVs 20:11:29 Integrated Voltage Measurement... 20:11:38 Voltage Offset Correction: v_off_ini = 625.721 uV, v_off_fin = 611.589 uV 20:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -113.969 uVs 20:11:38 Integrated Voltage Measurement... 20:11:47 Voltage Offset Correction: v_off_ini = 614.019 uV, v_off_fin = 618.694 uV 20:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 125.477 uVs 20:11:47 Integrated Voltage Measurement... 20:11:56 Voltage Offset Correction: v_off_ini = 633.520 uV, v_off_fin = 628.407 uV 20:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -109.561 uVs 20:11:56 Integrated Voltage Measurement... 20:12:05 Voltage Offset Correction: v_off_ini = 629.129 uV, v_off_fin = 638.011 uV 20:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 93.717 uVs 20:12:08 I2Y Average and RMS of Measurements VT = -113.031 +- 8.096 uVs I2Y = -10.399 +- 0.745 uTm^2 20:12:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:12:23 Integrated Voltage Measurement... 20:12:32 Voltage Offset Correction: v_off_ini = 611.997 uV, v_off_fin = 605.663 uV 20:12:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.892 uVs 20:12:32 Integrated Voltage Measurement... 20:12:41 Voltage Offset Correction: v_off_ini = 599.225 uV, v_off_fin = 614.309 uV 20:12:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.804 uVs 20:12:41 Integrated Voltage Measurement... 20:12:50 Voltage Offset Correction: v_off_ini = 609.812 uV, v_off_fin = 604.133 uV 20:12:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.215 uVs 20:12:50 Integrated Voltage Measurement... 20:12:59 Voltage Offset Correction: v_off_ini = 601.814 uV, v_off_fin = 597.831 uV 20:12:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.229 uVs 20:12:59 Integrated Voltage Measurement... 20:13:08 Voltage Offset Correction: v_off_ini = 609.167 uV, v_off_fin = 613.270 uV 20:13:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.195 uVs 20:13:08 Integrated Voltage Measurement... 20:13:17 Voltage Offset Correction: v_off_ini = 631.916 uV, v_off_fin = 614.319 uV 20:13:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.844 uVs 20:13:21 I1X Average and RMS of Measurements VT = -126.697 +- 12.135 uVs I1X = 25.339 +- 2.427 uTm 20:13:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:13:28 Integrated Voltage Measurement... 20:13:37 Voltage Offset Correction: v_off_ini = 634.562 uV, v_off_fin = 616.965 uV 20:13:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -198.642 uVs 20:13:37 Integrated Voltage Measurement... 20:13:46 Voltage Offset Correction: v_off_ini = 626.220 uV, v_off_fin = 639.284 uV 20:13:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.625 uVs 20:13:46 Integrated Voltage Measurement... 20:13:55 Voltage Offset Correction: v_off_ini = 632.430 uV, v_off_fin = 601.998 uV 20:13:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.405 uVs 20:13:55 Integrated Voltage Measurement... 20:14:04 Voltage Offset Correction: v_off_ini = 600.837 uV, v_off_fin = 616.797 uV 20:14:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.839 uVs 20:14:04 Integrated Voltage Measurement... 20:14:13 Voltage Offset Correction: v_off_ini = 619.266 uV, v_off_fin = 618.235 uV 20:14:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.058 uVs 20:14:13 Integrated Voltage Measurement... 20:14:22 Voltage Offset Correction: v_off_ini = 635.469 uV, v_off_fin = 637.403 uV 20:14:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.987 uVs 20:14:26 I1Y Average and RMS of Measurements VT = -206.092 +- 1.806 uVs I1Y = -41.219 +- 0.361 uTm 20:14:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:14:34 Integrated Voltage Measurement... 20:14:43 Voltage Offset Correction: v_off_ini = 612.097 uV, v_off_fin = 618.111 uV 20:14:43 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -114.086 uVs 20:14:43 Integrated Voltage Measurement... 20:14:52 Voltage Offset Correction: v_off_ini = 602.583 uV, v_off_fin = 581.636 uV 20:14:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.551 uVs 20:14:52 Integrated Voltage Measurement... 20:15:01 Voltage Offset Correction: v_off_ini = 592.479 uV, v_off_fin = 606.081 uV 20:15:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.486 uVs 20:15:01 Integrated Voltage Measurement... 20:15:10 Voltage Offset Correction: v_off_ini = 598.687 uV, v_off_fin = 587.109 uV 20:15:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.982 uVs 20:15:10 Integrated Voltage Measurement... 20:15:19 Voltage Offset Correction: v_off_ini = 598.038 uV, v_off_fin = 612.578 uV 20:15:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.117 uVs 20:15:19 Integrated Voltage Measurement... 20:15:28 Voltage Offset Correction: v_off_ini = 605.435 uV, v_off_fin = 610.309 uV 20:15:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 140.822 uVs 20:15:30 I2X Average and RMS of Measurements VT = -120.341 +- 6.470 uVs I2X = 11.072 +- 0.596 uTm^2 20:15:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:15:38 Integrated Voltage Measurement... 20:15:47 Voltage Offset Correction: v_off_ini = 586.856 uV, v_off_fin = 595.087 uV 20:15:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -114.502 uVs 20:15:47 Integrated Voltage Measurement... 20:15:56 Voltage Offset Correction: v_off_ini = 604.842 uV, v_off_fin = 625.331 uV 20:15:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 110.232 uVs 20:15:56 Integrated Voltage Measurement... 20:16:05 Voltage Offset Correction: v_off_ini = 605.314 uV, v_off_fin = 620.443 uV 20:16:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -117.023 uVs 20:16:05 Integrated Voltage Measurement... 20:16:14 Voltage Offset Correction: v_off_ini = 620.520 uV, v_off_fin = 611.789 uV 20:16:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 103.556 uVs 20:16:14 Integrated Voltage Measurement... 20:16:23 Voltage Offset Correction: v_off_ini = 592.237 uV, v_off_fin = 593.427 uV 20:16:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -114.569 uVs 20:16:23 Integrated Voltage Measurement... 20:16:32 Voltage Offset Correction: v_off_ini = 614.491 uV, v_off_fin = 627.489 uV 20:16:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 122.713 uVs 20:16:35 I2Y Average and RMS of Measurements VT = -113.766 +- 3.550 uVs I2Y = -10.466 +- 0.327 uTm^2 20:16:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:16:51 Integrated Voltage Measurement... 20:17:00 Voltage Offset Correction: v_off_ini = 614.669 uV, v_off_fin = 612.064 uV 20:17:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.447 uVs 20:17:00 Integrated Voltage Measurement... 20:17:09 Voltage Offset Correction: v_off_ini = 615.675 uV, v_off_fin = 617.362 uV 20:17:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.791 uVs 20:17:09 Integrated Voltage Measurement... 20:17:18 Voltage Offset Correction: v_off_ini = 623.930 uV, v_off_fin = 599.941 uV 20:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.384 uVs 20:17:18 Integrated Voltage Measurement... 20:17:27 Voltage Offset Correction: v_off_ini = 612.808 uV, v_off_fin = 626.321 uV 20:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.845 uVs 20:17:27 Integrated Voltage Measurement... 20:17:36 Voltage Offset Correction: v_off_ini = 622.250 uV, v_off_fin = 609.573 uV 20:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.539 uVs 20:17:36 Integrated Voltage Measurement... 20:17:45 Voltage Offset Correction: v_off_ini = 638.983 uV, v_off_fin = 629.416 uV 20:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.599 uVs 20:17:49 I1X Average and RMS of Measurements VT = -121.767 +- 9.404 uVs I1X = 24.353 +- 1.881 uTm 20:17:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:17:56 Integrated Voltage Measurement... 20:18:05 Voltage Offset Correction: v_off_ini = 634.584 uV, v_off_fin = 634.122 uV 20:18:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.514 uVs 20:18:05 Integrated Voltage Measurement... 20:18:14 Voltage Offset Correction: v_off_ini = 609.313 uV, v_off_fin = 611.538 uV 20:18:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.361 uVs 20:18:14 Integrated Voltage Measurement... 20:18:23 Voltage Offset Correction: v_off_ini = 614.141 uV, v_off_fin = 597.779 uV 20:18:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.252 uVs 20:18:23 Integrated Voltage Measurement... 20:18:32 Voltage Offset Correction: v_off_ini = 606.887 uV, v_off_fin = 607.337 uV 20:18:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.705 uVs 20:18:32 Integrated Voltage Measurement... 20:18:41 Voltage Offset Correction: v_off_ini = 607.507 uV, v_off_fin = 596.058 uV 20:18:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.830 uVs 20:18:41 Integrated Voltage Measurement... 20:18:50 Voltage Offset Correction: v_off_ini = 618.111 uV, v_off_fin = 625.534 uV 20:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.767 uVs 20:18:54 I1Y Average and RMS of Measurements VT = -201.238 +- 7.947 uVs I1Y = -40.246 +- 1.589 uTm 20:18:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:19:02 Integrated Voltage Measurement... 20:19:11 Voltage Offset Correction: v_off_ini = 617.180 uV, v_off_fin = 622.392 uV 20:19:11 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.803 uVs 20:19:11 Integrated Voltage Measurement... 20:19:20 Voltage Offset Correction: v_off_ini = 618.913 uV, v_off_fin = 593.646 uV 20:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.362 uVs 20:19:20 Integrated Voltage Measurement... 20:19:29 Voltage Offset Correction: v_off_ini = 617.117 uV, v_off_fin = 627.670 uV 20:19:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -124.989 uVs 20:19:29 Integrated Voltage Measurement... 20:19:38 Voltage Offset Correction: v_off_ini = 615.556 uV, v_off_fin = 589.506 uV 20:19:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 139.535 uVs 20:19:38 Integrated Voltage Measurement... 20:19:47 Voltage Offset Correction: v_off_ini = 618.153 uV, v_off_fin = 612.152 uV 20:19:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.233 uVs 20:19:47 Integrated Voltage Measurement... 20:19:56 Voltage Offset Correction: v_off_ini = 621.148 uV, v_off_fin = 616.394 uV 20:19:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.654 uVs 20:19:58 I2X Average and RMS of Measurements VT = -123.096 +- 6.607 uVs I2X = 11.325 +- 0.609 uTm^2 20:20:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:20:06 Integrated Voltage Measurement... 20:20:15 Voltage Offset Correction: v_off_ini = 597.592 uV, v_off_fin = 588.564 uV 20:20:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -115.604 uVs 20:20:15 Integrated Voltage Measurement... 20:20:24 Voltage Offset Correction: v_off_ini = 597.973 uV, v_off_fin = 603.270 uV 20:20:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 104.544 uVs 20:20:24 Integrated Voltage Measurement... 20:20:33 Voltage Offset Correction: v_off_ini = 597.015 uV, v_off_fin = 606.704 uV 20:20:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -98.399 uVs 20:20:33 Integrated Voltage Measurement... 20:20:42 Voltage Offset Correction: v_off_ini = 600.046 uV, v_off_fin = 590.287 uV 20:20:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 144.913 uVs 20:20:42 Integrated Voltage Measurement... 20:20:51 Voltage Offset Correction: v_off_ini = 615.884 uV, v_off_fin = 618.876 uV 20:20:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -128.684 uVs 20:20:51 Integrated Voltage Measurement... 20:21:00 Voltage Offset Correction: v_off_ini = 617.994 uV, v_off_fin = 611.928 uV 20:21:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 129.627 uVs 20:21:03 I2Y Average and RMS of Measurements VT = -120.295 +- 7.849 uVs I2Y = -11.067 +- 0.722 uTm^2 20:21:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:21:19 Integrated Voltage Measurement... 20:21:28 Voltage Offset Correction: v_off_ini = 614.992 uV, v_off_fin = 632.356 uV 20:21:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.134 uVs 20:21:28 Integrated Voltage Measurement... 20:21:37 Voltage Offset Correction: v_off_ini = 643.787 uV, v_off_fin = 646.506 uV 20:21:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.660 uVs 20:21:37 Integrated Voltage Measurement... 20:21:46 Voltage Offset Correction: v_off_ini = 637.226 uV, v_off_fin = 629.374 uV 20:21:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.479 uVs 20:21:46 Integrated Voltage Measurement... 20:21:55 Voltage Offset Correction: v_off_ini = 607.222 uV, v_off_fin = 594.196 uV 20:21:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.826 uVs 20:21:55 Integrated Voltage Measurement... 20:22:04 Voltage Offset Correction: v_off_ini = 616.455 uV, v_off_fin = 640.568 uV 20:22:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.008 uVs 20:22:04 Integrated Voltage Measurement... 20:22:13 Voltage Offset Correction: v_off_ini = 639.916 uV, v_off_fin = 619.797 uV 20:22:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.231 uVs 20:22:17 I1X Average and RMS of Measurements VT = -142.556 +- 12.532 uVs I1X = 28.511 +- 2.506 uTm 20:22:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:22:24 Integrated Voltage Measurement... 20:22:33 Voltage Offset Correction: v_off_ini = 613.806 uV, v_off_fin = 610.246 uV 20:22:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.829 uVs 20:22:33 Integrated Voltage Measurement... 20:22:42 Voltage Offset Correction: v_off_ini = 618.749 uV, v_off_fin = 619.014 uV 20:22:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.688 uVs 20:22:42 Integrated Voltage Measurement... 20:22:51 Voltage Offset Correction: v_off_ini = 633.361 uV, v_off_fin = 636.144 uV 20:22:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.088 uVs 20:22:51 Integrated Voltage Measurement... 20:23:00 Voltage Offset Correction: v_off_ini = 626.035 uV, v_off_fin = 630.746 uV 20:23:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.661 uVs 20:23:00 Integrated Voltage Measurement... 20:23:09 Voltage Offset Correction: v_off_ini = 626.496 uV, v_off_fin = 622.826 uV 20:23:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.514 uVs 20:23:09 Integrated Voltage Measurement... 20:23:18 Voltage Offset Correction: v_off_ini = 627.426 uV, v_off_fin = 660.557 uV 20:23:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.290 uVs 20:23:22 I1Y Average and RMS of Measurements VT = -202.178 +- 4.433 uVs I1Y = -40.435 +- 0.887 uTm 20:23:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:23:30 Integrated Voltage Measurement... 20:23:39 Voltage Offset Correction: v_off_ini = 629.337 uV, v_off_fin = 638.541 uV 20:23:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -142.214 uVs 20:23:39 Integrated Voltage Measurement... 20:23:48 Voltage Offset Correction: v_off_ini = 612.910 uV, v_off_fin = 606.839 uV 20:23:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.337 uVs 20:23:48 Integrated Voltage Measurement... 20:23:57 Voltage Offset Correction: v_off_ini = 643.248 uV, v_off_fin = 630.842 uV 20:23:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.839 uVs 20:23:57 Integrated Voltage Measurement... 20:24:06 Voltage Offset Correction: v_off_ini = 600.046 uV, v_off_fin = 601.779 uV 20:24:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.526 uVs 20:24:06 Integrated Voltage Measurement... 20:24:15 Voltage Offset Correction: v_off_ini = 626.181 uV, v_off_fin = 636.415 uV 20:24:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.664 uVs 20:24:15 Integrated Voltage Measurement... 20:24:24 Voltage Offset Correction: v_off_ini = 623.037 uV, v_off_fin = 578.831 uV 20:24:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.309 uVs 20:24:27 I2X Average and RMS of Measurements VT = -139.648 +- 2.581 uVs I2X = 12.847 +- 0.237 uTm^2 20:24:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:24:34 Integrated Voltage Measurement... 20:24:43 Voltage Offset Correction: v_off_ini = 602.386 uV, v_off_fin = 598.046 uV 20:24:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -121.962 uVs 20:24:43 Integrated Voltage Measurement... 20:24:52 Voltage Offset Correction: v_off_ini = 627.570 uV, v_off_fin = 626.128 uV 20:24:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 131.576 uVs 20:24:52 Integrated Voltage Measurement... 20:25:01 Voltage Offset Correction: v_off_ini = 609.694 uV, v_off_fin = 613.352 uV 20:25:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -125.572 uVs 20:25:01 Integrated Voltage Measurement... 20:25:10 Voltage Offset Correction: v_off_ini = 629.145 uV, v_off_fin = 616.257 uV 20:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 117.258 uVs 20:25:10 Integrated Voltage Measurement... 20:25:19 Voltage Offset Correction: v_off_ini = 617.194 uV, v_off_fin = 608.117 uV 20:25:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -128.478 uVs 20:25:20 Integrated Voltage Measurement... 20:25:28 Voltage Offset Correction: v_off_ini = 612.711 uV, v_off_fin = 607.847 uV 20:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 101.625 uVs 20:25:31 I2Y Average and RMS of Measurements VT = -121.078 +- 4.789 uVs I2Y = -11.139 +- 0.441 uTm^2 20:25:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:25:49 Integrated Voltage Measurement... 20:25:58 Voltage Offset Correction: v_off_ini = 638.882 uV, v_off_fin = 618.677 uV 20:25:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.889 uVs 20:25:58 Integrated Voltage Measurement... 20:26:07 Voltage Offset Correction: v_off_ini = 624.648 uV, v_off_fin = 600.082 uV 20:26:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.471 uVs 20:26:07 Integrated Voltage Measurement... 20:26:16 Voltage Offset Correction: v_off_ini = 612.098 uV, v_off_fin = 608.814 uV 20:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.582 uVs 20:26:16 Integrated Voltage Measurement... 20:26:25 Voltage Offset Correction: v_off_ini = 588.473 uV, v_off_fin = 604.678 uV 20:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.382 uVs 20:26:25 Integrated Voltage Measurement... 20:26:34 Voltage Offset Correction: v_off_ini = 593.327 uV, v_off_fin = 584.161 uV 20:26:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.465 uVs 20:26:34 Integrated Voltage Measurement... 20:26:43 Voltage Offset Correction: v_off_ini = 607.782 uV, v_off_fin = 592.197 uV 20:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.664 uVs 20:26:48 I1X Average and RMS of Measurements VT = -143.742 +- 6.807 uVs I1X = 28.748 +- 1.361 uTm 20:26:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:26:54 Integrated Voltage Measurement... 20:27:03 Voltage Offset Correction: v_off_ini = 568.864 uV, v_off_fin = 559.243 uV 20:27:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.818 uVs 20:27:03 Integrated Voltage Measurement... 20:27:12 Voltage Offset Correction: v_off_ini = 531.420 uV, v_off_fin = 559.952 uV 20:27:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.303 uVs 20:27:12 Integrated Voltage Measurement... 20:27:21 Voltage Offset Correction: v_off_ini = 559.841 uV, v_off_fin = 545.020 uV 20:27:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.169 uVs 20:27:21 Integrated Voltage Measurement... 20:27:30 Voltage Offset Correction: v_off_ini = 568.017 uV, v_off_fin = 590.706 uV 20:27:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.398 uVs 20:27:30 Integrated Voltage Measurement... 20:27:39 Voltage Offset Correction: v_off_ini = 579.695 uV, v_off_fin = 573.385 uV 20:27:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.115 uVs 20:27:39 Integrated Voltage Measurement... 20:27:48 Voltage Offset Correction: v_off_ini = 572.528 uV, v_off_fin = 593.288 uV 20:27:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.635 uVs 20:27:53 I1Y Average and RMS of Measurements VT = -198.906 +- 2.961 uVs I1Y = -39.781 +- 0.592 uTm 20:27:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:28:00 Integrated Voltage Measurement... 20:28:09 Voltage Offset Correction: v_off_ini = 571.729 uV, v_off_fin = 594.421 uV 20:28:09 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -134.403 uVs 20:28:09 Integrated Voltage Measurement... 20:28:18 Voltage Offset Correction: v_off_ini = 583.688 uV, v_off_fin = 579.506 uV 20:28:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 172.581 uVs 20:28:18 Integrated Voltage Measurement... 20:28:27 Voltage Offset Correction: v_off_ini = 600.453 uV, v_off_fin = 596.690 uV 20:28:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.280 uVs 20:28:27 Integrated Voltage Measurement... 20:28:36 Voltage Offset Correction: v_off_ini = 587.207 uV, v_off_fin = 577.713 uV 20:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.830 uVs 20:28:36 Integrated Voltage Measurement... 20:28:45 Voltage Offset Correction: v_off_ini = 591.721 uV, v_off_fin = 598.169 uV 20:28:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.508 uVs 20:28:45 Integrated Voltage Measurement... 20:28:54 Voltage Offset Correction: v_off_ini = 600.767 uV, v_off_fin = 583.410 uV 20:28:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.712 uVs 20:28:57 I2X Average and RMS of Measurements VT = -138.386 +- 11.518 uVs I2X = 12.732 +- 1.059 uTm^2 20:29:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:29:05 Integrated Voltage Measurement... 20:29:14 Voltage Offset Correction: v_off_ini = 573.947 uV, v_off_fin = 575.371 uV 20:29:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -120.717 uVs 20:29:14 Integrated Voltage Measurement... 20:29:23 Voltage Offset Correction: v_off_ini = 568.798 uV, v_off_fin = 586.351 uV 20:29:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 135.125 uVs 20:29:23 Integrated Voltage Measurement... 20:29:32 Voltage Offset Correction: v_off_ini = 589.401 uV, v_off_fin = 565.866 uV 20:29:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -121.212 uVs 20:29:32 Integrated Voltage Measurement... 20:29:41 Voltage Offset Correction: v_off_ini = 535.615 uV, v_off_fin = 546.854 uV 20:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 127.520 uVs 20:29:41 Integrated Voltage Measurement... 20:29:50 Voltage Offset Correction: v_off_ini = 566.288 uV, v_off_fin = 556.101 uV 20:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -143.878 uVs 20:29:50 Integrated Voltage Measurement... 20:29:59 Voltage Offset Correction: v_off_ini = 565.081 uV, v_off_fin = 586.543 uV 20:29:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 155.543 uVs 20:30:01 I2Y Average and RMS of Measurements VT = -133.999 +- 11.204 uVs I2Y = -12.328 +- 1.031 uTm^2 20:30:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:30:19 Integrated Voltage Measurement... 20:30:28 Voltage Offset Correction: v_off_ini = 551.933 uV, v_off_fin = 554.349 uV 20:30:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.776 uVs 20:30:28 Integrated Voltage Measurement... 20:30:37 Voltage Offset Correction: v_off_ini = 571.198 uV, v_off_fin = 599.916 uV 20:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.409 uVs 20:30:38 Integrated Voltage Measurement... 20:30:46 Voltage Offset Correction: v_off_ini = 580.974 uV, v_off_fin = 586.703 uV 20:30:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.717 uVs 20:30:47 Integrated Voltage Measurement... 20:30:55 Voltage Offset Correction: v_off_ini = 582.289 uV, v_off_fin = 582.047 uV 20:30:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.521 uVs 20:30:56 Integrated Voltage Measurement... 20:31:05 Voltage Offset Correction: v_off_ini = 571.501 uV, v_off_fin = 570.621 uV 20:31:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.159 uVs 20:31:05 Integrated Voltage Measurement... 20:31:14 Voltage Offset Correction: v_off_ini = 570.171 uV, v_off_fin = 558.101 uV 20:31:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 164.972 uVs 20:31:18 I1X Average and RMS of Measurements VT = -133.426 +- 15.718 uVs I1X = 26.685 +- 3.144 uTm 20:31:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:31:25 Integrated Voltage Measurement... 20:31:33 Voltage Offset Correction: v_off_ini = 597.964 uV, v_off_fin = 594.316 uV 20:31:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.525 uVs 20:31:34 Integrated Voltage Measurement... 20:31:43 Voltage Offset Correction: v_off_ini = 601.864 uV, v_off_fin = 606.248 uV 20:31:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.709 uVs 20:31:43 Integrated Voltage Measurement... 20:31:52 Voltage Offset Correction: v_off_ini = 566.502 uV, v_off_fin = 553.279 uV 20:31:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.532 uVs 20:31:52 Integrated Voltage Measurement... 20:32:00 Voltage Offset Correction: v_off_ini = 570.736 uV, v_off_fin = 590.355 uV 20:32:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.965 uVs 20:32:01 Integrated Voltage Measurement... 20:32:10 Voltage Offset Correction: v_off_ini = 575.555 uV, v_off_fin = 571.327 uV 20:32:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.639 uVs 20:32:10 Integrated Voltage Measurement... 20:32:18 Voltage Offset Correction: v_off_ini = 566.862 uV, v_off_fin = 594.110 uV 20:32:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.352 uVs 20:32:23 I1Y Average and RMS of Measurements VT = -206.787 +- 6.604 uVs I1Y = -41.357 +- 1.321 uTm 20:32:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:32:30 Integrated Voltage Measurement... 20:32:39 Voltage Offset Correction: v_off_ini = 568.009 uV, v_off_fin = 574.251 uV 20:32:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -130.980 uVs 20:32:39 Integrated Voltage Measurement... 20:32:48 Voltage Offset Correction: v_off_ini = 566.627 uV, v_off_fin = 550.024 uV 20:32:48 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 141.863 uVs 20:32:49 Integrated Voltage Measurement... 20:32:57 Voltage Offset Correction: v_off_ini = 567.037 uV, v_off_fin = 572.497 uV 20:32:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.327 uVs 20:32:58 Integrated Voltage Measurement... 20:33:07 Voltage Offset Correction: v_off_ini = 579.441 uV, v_off_fin = 578.114 uV 20:33:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.999 uVs 20:33:07 Integrated Voltage Measurement... 20:33:16 Voltage Offset Correction: v_off_ini = 575.829 uV, v_off_fin = 591.158 uV 20:33:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.825 uVs 20:33:16 Integrated Voltage Measurement... 20:33:25 Voltage Offset Correction: v_off_ini = 575.036 uV, v_off_fin = 562.173 uV 20:33:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.942 uVs 20:33:27 I2X Average and RMS of Measurements VT = -132.323 +- 2.900 uVs I2X = 12.174 +- 0.267 uTm^2 20:33:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:33:35 Integrated Voltage Measurement... 20:33:44 Voltage Offset Correction: v_off_ini = 559.490 uV, v_off_fin = 574.136 uV 20:33:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -126.429 uVs 20:33:44 Integrated Voltage Measurement... 20:33:53 Voltage Offset Correction: v_off_ini = 575.214 uV, v_off_fin = 581.204 uV 20:33:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 139.335 uVs 20:33:53 Integrated Voltage Measurement... 20:34:02 Voltage Offset Correction: v_off_ini = 559.292 uV, v_off_fin = 561.309 uV 20:34:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -145.945 uVs 20:34:02 Integrated Voltage Measurement... 20:34:11 Voltage Offset Correction: v_off_ini = 568.297 uV, v_off_fin = 560.859 uV 20:34:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.709 uVs 20:34:11 Integrated Voltage Measurement... 20:34:20 Voltage Offset Correction: v_off_ini = 577.012 uV, v_off_fin = 587.176 uV 20:34:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -144.554 uVs 20:34:20 Integrated Voltage Measurement... 20:34:29 Voltage Offset Correction: v_off_ini = 587.460 uV, v_off_fin = 576.887 uV 20:34:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 142.729 uVs 20:34:31 I2Y Average and RMS of Measurements VT = -139.283 +- 4.624 uVs I2Y = -12.814 +- 0.425 uTm^2 20:34:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:34:50 Integrated Voltage Measurement... 20:34:59 Voltage Offset Correction: v_off_ini = 559.909 uV, v_off_fin = 562.123 uV 20:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.922 uVs 20:34:59 Integrated Voltage Measurement... 20:35:08 Voltage Offset Correction: v_off_ini = 582.804 uV, v_off_fin = 582.226 uV 20:35:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.458 uVs 20:35:08 Integrated Voltage Measurement... 20:35:17 Voltage Offset Correction: v_off_ini = 593.843 uV, v_off_fin = 571.557 uV 20:35:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.709 uVs 20:35:17 Integrated Voltage Measurement... 20:35:26 Voltage Offset Correction: v_off_ini = 574.527 uV, v_off_fin = 584.667 uV 20:35:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 131.371 uVs 20:35:26 Integrated Voltage Measurement... 20:35:35 Voltage Offset Correction: v_off_ini = 573.363 uV, v_off_fin = 583.782 uV 20:35:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -138.376 uVs 20:35:35 Integrated Voltage Measurement... 20:35:44 Voltage Offset Correction: v_off_ini = 586.583 uV, v_off_fin = 570.666 uV 20:35:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.642 uVs 20:35:48 I1X Average and RMS of Measurements VT = -121.913 +- 10.407 uVs I1X = 24.382 +- 2.081 uTm 20:35:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:35:55 Integrated Voltage Measurement... 20:36:04 Voltage Offset Correction: v_off_ini = 564.516 uV, v_off_fin = 576.611 uV 20:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.170 uVs 20:36:04 Integrated Voltage Measurement... 20:36:13 Voltage Offset Correction: v_off_ini = 560.750 uV, v_off_fin = 577.893 uV 20:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.572 uVs 20:36:13 Integrated Voltage Measurement... 20:36:22 Voltage Offset Correction: v_off_ini = 557.147 uV, v_off_fin = 560.695 uV 20:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.364 uVs 20:36:22 Integrated Voltage Measurement... 20:36:31 Voltage Offset Correction: v_off_ini = 563.254 uV, v_off_fin = 578.957 uV 20:36:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.873 uVs 20:36:31 Integrated Voltage Measurement... 20:36:40 Voltage Offset Correction: v_off_ini = 580.772 uV, v_off_fin = 569.408 uV 20:36:40 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -205.993 uVs 20:36:40 Integrated Voltage Measurement... 20:36:49 Voltage Offset Correction: v_off_ini = 564.927 uV, v_off_fin = 569.967 uV 20:36:49 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 215.198 uVs 20:36:53 I1Y Average and RMS of Measurements VT = -211.528 +- 1.303 uVs I1Y = -42.303 +- 0.263 uTm 20:36:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:37:01 Integrated Voltage Measurement... 20:37:09 Voltage Offset Correction: v_off_ini = 562.345 uV, v_off_fin = 555.793 uV 20:37:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.301 uVs 20:37:10 Integrated Voltage Measurement... 20:37:19 Voltage Offset Correction: v_off_ini = 578.268 uV, v_off_fin = 559.795 uV 20:37:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.139 uVs 20:37:19 Integrated Voltage Measurement... 20:37:28 Voltage Offset Correction: v_off_ini = 565.423 uV, v_off_fin = 572.621 uV 20:37:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.189 uVs 20:37:28 Integrated Voltage Measurement... 20:37:37 Voltage Offset Correction: v_off_ini = 554.973 uV, v_off_fin = 533.782 uV 20:37:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.764 uVs 20:37:37 Integrated Voltage Measurement... 20:37:46 Voltage Offset Correction: v_off_ini = 546.296 uV, v_off_fin = 556.412 uV 20:37:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.323 uVs 20:37:46 Integrated Voltage Measurement... 20:37:55 Voltage Offset Correction: v_off_ini = 565.203 uV, v_off_fin = 563.295 uV 20:37:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.687 uVs 20:37:57 I2X Average and RMS of Measurements VT = -133.067 +- 3.827 uVs I2X = 12.242 +- 0.352 uTm^2 20:38:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:38:05 Integrated Voltage Measurement... 20:38:14 Voltage Offset Correction: v_off_ini = 566.523 uV, v_off_fin = 553.575 uV 20:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.343 uVs 20:38:14 Integrated Voltage Measurement... 20:38:23 Voltage Offset Correction: v_off_ini = 561.468 uV, v_off_fin = 564.481 uV 20:38:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.745 uVs 20:38:23 Integrated Voltage Measurement... 20:38:32 Voltage Offset Correction: v_off_ini = 570.593 uV, v_off_fin = 568.759 uV 20:38:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.032 uVs 20:38:32 Integrated Voltage Measurement... 20:38:41 Voltage Offset Correction: v_off_ini = 570.401 uV, v_off_fin = 556.787 uV 20:38:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 138.963 uVs 20:38:41 Integrated Voltage Measurement... 20:38:50 Voltage Offset Correction: v_off_ini = 574.578 uV, v_off_fin = 567.219 uV 20:38:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.963 uVs 20:38:50 Integrated Voltage Measurement... 20:38:59 Voltage Offset Correction: v_off_ini = 573.235 uV, v_off_fin = 553.636 uV 20:38:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 161.928 uVs 20:39:01 I2Y Average and RMS of Measurements VT = -151.662 +- 3.390 uVs I2Y = -13.953 +- 0.312 uTm^2 20:39:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:39:19 Integrated Voltage Measurement... 20:39:28 Voltage Offset Correction: v_off_ini = 553.758 uV, v_off_fin = 565.637 uV 20:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.271 uVs 20:39:29 Integrated Voltage Measurement... 20:39:37 Voltage Offset Correction: v_off_ini = 542.351 uV, v_off_fin = 547.309 uV 20:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.057 uVs 20:39:38 Integrated Voltage Measurement... 20:39:46 Voltage Offset Correction: v_off_ini = 535.897 uV, v_off_fin = 530.641 uV 20:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.389 uVs 20:39:47 Integrated Voltage Measurement... 20:39:55 Voltage Offset Correction: v_off_ini = 556.468 uV, v_off_fin = 556.583 uV 20:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.879 uVs 20:39:56 Integrated Voltage Measurement... 20:40:04 Voltage Offset Correction: v_off_ini = 538.698 uV, v_off_fin = 535.364 uV 20:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.131 uVs 20:40:05 Integrated Voltage Measurement... 20:40:13 Voltage Offset Correction: v_off_ini = 525.734 uV, v_off_fin = 527.033 uV 20:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.605 uVs 20:40:18 I1X Average and RMS of Measurements VT = -121.889 +- 4.756 uVs I1X = 24.378 +- 0.951 uTm 20:40:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:40:24 Integrated Voltage Measurement... 20:40:33 Voltage Offset Correction: v_off_ini = 552.989 uV, v_off_fin = 533.725 uV 20:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.266 uVs 20:40:33 Integrated Voltage Measurement... 20:40:42 Voltage Offset Correction: v_off_ini = 530.327 uV, v_off_fin = 560.699 uV 20:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.034 uVs 20:40:42 Integrated Voltage Measurement... 20:40:51 Voltage Offset Correction: v_off_ini = 547.334 uV, v_off_fin = 540.227 uV 20:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.615 uVs 20:40:51 Integrated Voltage Measurement... 20:41:00 Voltage Offset Correction: v_off_ini = 553.168 uV, v_off_fin = 577.233 uV 20:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.524 uVs 20:41:00 Integrated Voltage Measurement... 20:41:09 Voltage Offset Correction: v_off_ini = 547.831 uV, v_off_fin = 526.950 uV 20:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.921 uVs 20:41:09 Integrated Voltage Measurement... 20:41:18 Voltage Offset Correction: v_off_ini = 550.737 uV, v_off_fin = 561.194 uV 20:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.203 uVs 20:41:23 I1Y Average and RMS of Measurements VT = -219.427 +- 7.680 uVs I1Y = -43.885 +- 1.536 uTm 20:41:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:41:30 Integrated Voltage Measurement... 20:41:39 Voltage Offset Correction: v_off_ini = 523.267 uV, v_off_fin = 542.181 uV 20:41:39 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -122.786 uVs 20:41:39 Integrated Voltage Measurement... 20:41:48 Voltage Offset Correction: v_off_ini = 561.590 uV, v_off_fin = 548.609 uV 20:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.082 uVs 20:41:48 Integrated Voltage Measurement... 20:41:57 Voltage Offset Correction: v_off_ini = 563.410 uV, v_off_fin = 566.130 uV 20:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.008 uVs 20:41:57 Integrated Voltage Measurement... 20:42:06 Voltage Offset Correction: v_off_ini = 559.945 uV, v_off_fin = 563.924 uV 20:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.317 uVs 20:42:06 Integrated Voltage Measurement... 20:42:15 Voltage Offset Correction: v_off_ini = 586.522 uV, v_off_fin = 582.008 uV 20:42:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -143.540 uVs 20:42:15 Integrated Voltage Measurement... 20:42:24 Voltage Offset Correction: v_off_ini = 561.700 uV, v_off_fin = 579.705 uV 20:42:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 140.427 uVs 20:42:27 I2X Average and RMS of Measurements VT = -135.193 +- 7.380 uVs I2X = 12.438 +- 0.680 uTm^2 20:42:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:42:34 Integrated Voltage Measurement... 20:42:43 Voltage Offset Correction: v_off_ini = 585.667 uV, v_off_fin = 569.616 uV 20:42:43 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -155.066 uVs 20:42:43 Integrated Voltage Measurement... 20:42:52 Voltage Offset Correction: v_off_ini = 554.584 uV, v_off_fin = 547.244 uV 20:42:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.186 uVs 20:42:52 Integrated Voltage Measurement... 20:43:01 Voltage Offset Correction: v_off_ini = 569.725 uV, v_off_fin = 565.741 uV 20:43:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.856 uVs 20:43:01 Integrated Voltage Measurement... 20:43:10 Voltage Offset Correction: v_off_ini = 568.721 uV, v_off_fin = 569.132 uV 20:43:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.431 uVs 20:43:10 Integrated Voltage Measurement... 20:43:19 Voltage Offset Correction: v_off_ini = 559.532 uV, v_off_fin = 530.197 uV 20:43:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.888 uVs 20:43:19 Integrated Voltage Measurement... 20:43:28 Voltage Offset Correction: v_off_ini = 536.332 uV, v_off_fin = 541.897 uV 20:43:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.739 uVs 20:43:31 I2Y Average and RMS of Measurements VT = -166.861 +- 1.273 uVs I2Y = -15.351 +- 0.117 uTm^2 20:43:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:43:49 Integrated Voltage Measurement... 20:43:58 Voltage Offset Correction: v_off_ini = 562.779 uV, v_off_fin = 555.470 uV 20:43:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.960 uVs 20:43:58 Integrated Voltage Measurement... 20:44:07 Voltage Offset Correction: v_off_ini = 557.992 uV, v_off_fin = 573.932 uV 20:44:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.457 uVs 20:44:07 Integrated Voltage Measurement... 20:44:16 Voltage Offset Correction: v_off_ini = 556.087 uV, v_off_fin = 563.046 uV 20:44:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.301 uVs 20:44:16 Integrated Voltage Measurement... 20:44:25 Voltage Offset Correction: v_off_ini = 570.032 uV, v_off_fin = 587.792 uV 20:44:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.747 uVs 20:44:25 Integrated Voltage Measurement... 20:44:34 Voltage Offset Correction: v_off_ini = 577.623 uV, v_off_fin = 572.225 uV 20:44:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.431 uVs 20:44:34 Integrated Voltage Measurement... 20:44:43 Voltage Offset Correction: v_off_ini = 559.075 uV, v_off_fin = 575.836 uV 20:44:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.091 uVs 20:44:47 I1X Average and RMS of Measurements VT = -126.831 +- 4.633 uVs I1X = 25.366 +- 0.927 uTm 20:44:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:44:54 Integrated Voltage Measurement... 20:45:03 Voltage Offset Correction: v_off_ini = 573.853 uV, v_off_fin = 564.726 uV 20:45:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.617 uVs 20:45:03 Integrated Voltage Measurement... 20:45:12 Voltage Offset Correction: v_off_ini = 570.866 uV, v_off_fin = 564.478 uV 20:45:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.134 uVs 20:45:12 Integrated Voltage Measurement... 20:45:21 Voltage Offset Correction: v_off_ini = 574.735 uV, v_off_fin = 552.525 uV 20:45:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.366 uVs 20:45:21 Integrated Voltage Measurement... 20:45:30 Voltage Offset Correction: v_off_ini = 563.122 uV, v_off_fin = 576.635 uV 20:45:30 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.489 uVs 20:45:30 Integrated Voltage Measurement... 20:45:39 Voltage Offset Correction: v_off_ini = 526.797 uV, v_off_fin = 522.177 uV 20:45:39 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -228.481 uVs 20:45:39 Integrated Voltage Measurement... 20:45:48 Voltage Offset Correction: v_off_ini = 550.846 uV, v_off_fin = 559.906 uV 20:45:48 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 219.327 uVs 20:45:52 I1Y Average and RMS of Measurements VT = -223.235 +- 3.725 uVs I1Y = -44.643 +- 0.744 uTm 20:45:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:46:00 Integrated Voltage Measurement... 20:46:09 Voltage Offset Correction: v_off_ini = 567.286 uV, v_off_fin = 575.187 uV 20:46:09 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -130.896 uVs 20:46:09 Integrated Voltage Measurement... 20:46:18 Voltage Offset Correction: v_off_ini = 552.945 uV, v_off_fin = 551.575 uV 20:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.466 uVs 20:46:18 Integrated Voltage Measurement... 20:46:27 Voltage Offset Correction: v_off_ini = 538.871 uV, v_off_fin = 553.923 uV 20:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.969 uVs 20:46:27 Integrated Voltage Measurement... 20:46:36 Voltage Offset Correction: v_off_ini = 554.747 uV, v_off_fin = 521.716 uV 20:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.816 uVs 20:46:36 Integrated Voltage Measurement... 20:46:45 Voltage Offset Correction: v_off_ini = 547.077 uV, v_off_fin = 550.533 uV 20:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.998 uVs 20:46:45 Integrated Voltage Measurement... 20:46:54 Voltage Offset Correction: v_off_ini = 557.638 uV, v_off_fin = 541.107 uV 20:46:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.683 uVs 20:46:56 I2X Average and RMS of Measurements VT = -127.638 +- 0.227 uVs I2X = 11.742 +- 0.021 uTm^2 20:47:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:47:04 Integrated Voltage Measurement... 20:47:13 Voltage Offset Correction: v_off_ini = 552.787 uV, v_off_fin = 553.500 uV 20:47:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.483 uVs 20:47:13 Integrated Voltage Measurement... 20:47:22 Voltage Offset Correction: v_off_ini = 559.776 uV, v_off_fin = 567.140 uV 20:47:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.863 uVs 20:47:22 Integrated Voltage Measurement... 20:47:31 Voltage Offset Correction: v_off_ini = 554.797 uV, v_off_fin = 547.767 uV 20:47:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.747 uVs 20:47:31 Integrated Voltage Measurement... 20:47:40 Voltage Offset Correction: v_off_ini = 551.218 uV, v_off_fin = 559.049 uV 20:47:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.866 uVs 20:47:40 Integrated Voltage Measurement... 20:47:49 Voltage Offset Correction: v_off_ini = 563.392 uV, v_off_fin = 551.816 uV 20:47:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.453 uVs 20:47:49 Integrated Voltage Measurement... 20:47:58 Voltage Offset Correction: v_off_ini = 544.691 uV, v_off_fin = 525.870 uV 20:47:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.663 uVs 20:48:00 I2Y Average and RMS of Measurements VT = -172.512 +- 5.464 uVs I2Y = -15.871 +- 0.503 uTm^2 20:48:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:48:19 Integrated Voltage Measurement... 20:48:28 Voltage Offset Correction: v_off_ini = 545.740 uV, v_off_fin = 543.328 uV 20:48:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.453 uVs 20:48:28 Integrated Voltage Measurement... 20:48:37 Voltage Offset Correction: v_off_ini = 569.880 uV, v_off_fin = 563.395 uV 20:48:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.304 uVs 20:48:37 Integrated Voltage Measurement... 20:48:46 Voltage Offset Correction: v_off_ini = 550.220 uV, v_off_fin = 549.184 uV 20:48:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.068 uVs 20:48:46 Integrated Voltage Measurement... 20:48:55 Voltage Offset Correction: v_off_ini = 554.948 uV, v_off_fin = 560.294 uV 20:48:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.564 uVs 20:48:55 Integrated Voltage Measurement... 20:49:04 Voltage Offset Correction: v_off_ini = 535.795 uV, v_off_fin = 552.954 uV 20:49:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.013 uVs 20:49:04 Integrated Voltage Measurement... 20:49:13 Voltage Offset Correction: v_off_ini = 544.935 uV, v_off_fin = 544.911 uV 20:49:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.584 uVs 20:49:17 I1X Average and RMS of Measurements VT = -113.831 +- 2.890 uVs I1X = 22.766 +- 0.578 uTm 20:49:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:49:24 Integrated Voltage Measurement... 20:49:33 Voltage Offset Correction: v_off_ini = 542.753 uV, v_off_fin = 532.765 uV 20:49:33 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -215.666 uVs 20:49:33 Integrated Voltage Measurement... 20:49:42 Voltage Offset Correction: v_off_ini = 543.830 uV, v_off_fin = 565.820 uV 20:49:42 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 216.006 uVs 20:49:42 Integrated Voltage Measurement... 20:49:51 Voltage Offset Correction: v_off_ini = 550.848 uV, v_off_fin = 532.750 uV 20:49:51 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -229.585 uVs 20:49:51 Integrated Voltage Measurement... 20:50:00 Voltage Offset Correction: v_off_ini = 551.395 uV, v_off_fin = 577.481 uV 20:50:00 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 230.813 uVs 20:50:00 Integrated Voltage Measurement... 20:50:09 Voltage Offset Correction: v_off_ini = 569.949 uV, v_off_fin = 549.322 uV 20:50:09 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5001 mm dXY = 0.5001 mm VT = -215.810 uVs 20:50:09 Integrated Voltage Measurement... 20:50:18 Voltage Offset Correction: v_off_ini = 539.972 uV, v_off_fin = 566.523 uV 20:50:18 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 235.604 uVs 20:50:22 I1Y Average and RMS of Measurements VT = -223.914 +- 5.999 uVs I1Y = -44.774 +- 1.200 uTm 20:50:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:50:30 Integrated Voltage Measurement... 20:50:39 Voltage Offset Correction: v_off_ini = 560.204 uV, v_off_fin = 556.949 uV 20:50:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -125.440 uVs 20:50:39 Integrated Voltage Measurement... 20:50:48 Voltage Offset Correction: v_off_ini = 559.689 uV, v_off_fin = 547.926 uV 20:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.059 uVs 20:50:48 Integrated Voltage Measurement... 20:50:57 Voltage Offset Correction: v_off_ini = 557.310 uV, v_off_fin = 573.427 uV 20:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.066 uVs 20:50:57 Integrated Voltage Measurement... 20:51:06 Voltage Offset Correction: v_off_ini = 567.985 uV, v_off_fin = 553.460 uV 20:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.714 uVs 20:51:06 Integrated Voltage Measurement... 20:51:15 Voltage Offset Correction: v_off_ini = 542.836 uV, v_off_fin = 556.031 uV 20:51:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.339 uVs 20:51:15 Integrated Voltage Measurement... 20:51:24 Voltage Offset Correction: v_off_ini = 550.115 uV, v_off_fin = 524.541 uV 20:51:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.075 uVs 20:51:26 I2X Average and RMS of Measurements VT = -115.282 +- 9.841 uVs I2X = 10.606 +- 0.905 uTm^2 20:51:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:51:34 Integrated Voltage Measurement... 20:51:43 Voltage Offset Correction: v_off_ini = 549.183 uV, v_off_fin = 533.978 uV 20:51:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.501 uVs 20:51:43 Integrated Voltage Measurement... 20:51:52 Voltage Offset Correction: v_off_ini = 542.009 uV, v_off_fin = 548.948 uV 20:51:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.828 uVs 20:51:52 Integrated Voltage Measurement... 20:52:01 Voltage Offset Correction: v_off_ini = 553.275 uV, v_off_fin = 555.267 uV 20:52:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.470 uVs 20:52:01 Integrated Voltage Measurement... 20:52:10 Voltage Offset Correction: v_off_ini = 562.179 uV, v_off_fin = 587.622 uV 20:52:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.570 uVs 20:52:10 Integrated Voltage Measurement... 20:52:19 Voltage Offset Correction: v_off_ini = 563.714 uV, v_off_fin = 569.895 uV 20:52:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.510 uVs 20:52:19 Integrated Voltage Measurement... 20:52:28 Voltage Offset Correction: v_off_ini = 564.957 uV, v_off_fin = 567.265 uV 20:52:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.318 uVs 20:52:30 I2Y Average and RMS of Measurements VT = -180.866 +- 7.881 uVs I2Y = -16.640 +- 0.725 uTm^2 20:52:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm