SLAC Magnetic Measurements Date: 07-23-2026 Time: 14:20:04 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16336 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 4 Measurement Device: Stretched Wire Operator: YL Comment: 14:20:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:14 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:16 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:17 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:20:19 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:40:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:52 Integrated Voltage Measurement... 14:41:01 Voltage Offset Correction: v_off_ini = 2423.593 uV, v_off_fin = 2399.826 uV 14:41:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.460 uVs 14:41:01 Integrated Voltage Measurement... 14:41:10 Voltage Offset Correction: v_off_ini = 2408.249 uV, v_off_fin = 2383.386 uV 14:41:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.554 uVs 14:41:10 Integrated Voltage Measurement... 14:41:19 Voltage Offset Correction: v_off_ini = 2373.188 uV, v_off_fin = 2389.236 uV 14:41:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.443 uVs 14:41:19 Integrated Voltage Measurement... 14:41:28 Voltage Offset Correction: v_off_ini = 2421.556 uV, v_off_fin = 2396.594 uV 14:41:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.069 uVs 14:41:28 Integrated Voltage Measurement... 14:41:37 Voltage Offset Correction: v_off_ini = 2427.044 uV, v_off_fin = 2377.374 uV 14:41:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.823 uVs 14:41:37 Integrated Voltage Measurement... 14:41:46 Voltage Offset Correction: v_off_ini = 2382.982 uV, v_off_fin = 2351.677 uV 14:41:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.659 uVs 14:41:51 I1X Average and RMS of Measurements VT = -91.835 +- 26.871 uVs I1X = 18.367 +- 5.374 uTm 14:41:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:57 Integrated Voltage Measurement... 14:42:06 Voltage Offset Correction: v_off_ini = 2371.143 uV, v_off_fin = 2356.398 uV 14:42:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -244.335 uVs 14:42:06 Integrated Voltage Measurement... 14:42:15 Voltage Offset Correction: v_off_ini = 2329.957 uV, v_off_fin = 2367.847 uV 14:42:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 260.558 uVs 14:42:15 Integrated Voltage Measurement... 14:42:24 Voltage Offset Correction: v_off_ini = 2352.094 uV, v_off_fin = 2349.541 uV 14:42:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.855 uVs 14:42:24 Integrated Voltage Measurement... 14:42:33 Voltage Offset Correction: v_off_ini = 2403.191 uV, v_off_fin = 2391.631 uV 14:42:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.549 uVs 14:42:33 Integrated Voltage Measurement... 14:42:42 Voltage Offset Correction: v_off_ini = 2353.575 uV, v_off_fin = 2348.028 uV 14:42:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -225.098 uVs 14:42:42 Integrated Voltage Measurement... 14:42:51 Voltage Offset Correction: v_off_ini = 2355.747 uV, v_off_fin = 2392.704 uV 14:42:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 284.929 uVs 14:42:55 I1Y Average and RMS of Measurements VT = -249.221 +- 6.463 uVs I1Y = -49.840 +- 1.291 uTm 14:43:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:03 Integrated Voltage Measurement... 14:43:12 Voltage Offset Correction: v_off_ini = 2394.584 uV, v_off_fin = 2387.444 uV 14:43:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.759 uVs 14:43:12 Integrated Voltage Measurement... 14:43:21 Voltage Offset Correction: v_off_ini = 2379.495 uV, v_off_fin = 2411.152 uV 14:43:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.246 uVs 14:43:21 Integrated Voltage Measurement... 14:43:30 Voltage Offset Correction: v_off_ini = 2439.105 uV, v_off_fin = 2411.650 uV 14:43:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.839 uVs 14:43:30 Integrated Voltage Measurement... 14:43:39 Voltage Offset Correction: v_off_ini = 2440.223 uV, v_off_fin = 2426.757 uV 14:43:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.799 uVs 14:43:39 Integrated Voltage Measurement... 14:43:48 Voltage Offset Correction: v_off_ini = 2420.243 uV, v_off_fin = 2426.653 uV 14:43:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.357 uVs 14:43:48 Integrated Voltage Measurement... 14:43:57 Voltage Offset Correction: v_off_ini = 2443.666 uV, v_off_fin = 2473.125 uV 14:43:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.143 uVs 14:44:00 I2X Average and RMS of Measurements VT = -93.690 +- 16.176 uVs I2X = 8.620 +- 1.488 uTm^2 14:44:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:07 Integrated Voltage Measurement... 14:44:16 Voltage Offset Correction: v_off_ini = 2464.669 uV, v_off_fin = 2420.575 uV 14:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.842 uVs 14:44:16 Integrated Voltage Measurement... 14:44:25 Voltage Offset Correction: v_off_ini = 2428.222 uV, v_off_fin = 2428.648 uV 14:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.926 uVs 14:44:25 Integrated Voltage Measurement... 14:44:34 Voltage Offset Correction: v_off_ini = 2429.584 uV, v_off_fin = 2433.279 uV 14:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -440.720 uVs 14:44:34 Integrated Voltage Measurement... 14:44:43 Voltage Offset Correction: v_off_ini = 2454.352 uV, v_off_fin = 2422.190 uV 14:44:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 401.099 uVs 14:44:43 Integrated Voltage Measurement... 14:44:52 Voltage Offset Correction: v_off_ini = 2445.165 uV, v_off_fin = 2441.661 uV 14:44:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -406.709 uVs 14:44:52 Integrated Voltage Measurement... 14:45:01 Voltage Offset Correction: v_off_ini = 2454.115 uV, v_off_fin = 2409.460 uV 14:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 389.010 uVs 14:45:04 I2Y Average and RMS of Measurements VT = -413.884 +- 11.360 uVs I2Y = -38.079 +- 1.045 uTm^2 14:45:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:19 Integrated Voltage Measurement... 14:45:28 Voltage Offset Correction: v_off_ini = 2427.118 uV, v_off_fin = 2402.564 uV 14:45:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.841 uVs 14:45:28 Integrated Voltage Measurement... 14:45:37 Voltage Offset Correction: v_off_ini = 2412.504 uV, v_off_fin = 2441.176 uV 14:45:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.736 uVs 14:45:37 Integrated Voltage Measurement... 14:45:46 Voltage Offset Correction: v_off_ini = 2419.930 uV, v_off_fin = 2397.336 uV 14:45:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.799 uVs 14:45:46 Integrated Voltage Measurement... 14:45:55 Voltage Offset Correction: v_off_ini = 2378.371 uV, v_off_fin = 2403.889 uV 14:45:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.118 uVs 14:45:55 Integrated Voltage Measurement... 14:46:04 Voltage Offset Correction: v_off_ini = 2379.662 uV, v_off_fin = 2383.419 uV 14:46:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.240 uVs 14:46:04 Integrated Voltage Measurement... 14:46:13 Voltage Offset Correction: v_off_ini = 2395.740 uV, v_off_fin = 2389.291 uV 14:46:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.773 uVs 14:46:17 I1X Average and RMS of Measurements VT = -71.085 +- 10.474 uVs I1X = 14.217 +- 2.095 uTm 14:46:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:24 Integrated Voltage Measurement... 14:46:33 Voltage Offset Correction: v_off_ini = 2375.151 uV, v_off_fin = 2364.271 uV 14:46:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.903 uVs 14:46:33 Integrated Voltage Measurement... 14:46:42 Voltage Offset Correction: v_off_ini = 2377.185 uV, v_off_fin = 2395.440 uV 14:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.292 uVs 14:46:42 Integrated Voltage Measurement... 14:46:51 Voltage Offset Correction: v_off_ini = 2380.255 uV, v_off_fin = 2378.539 uV 14:46:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.999 uVs 14:46:51 Integrated Voltage Measurement... 14:47:00 Voltage Offset Correction: v_off_ini = 2409.436 uV, v_off_fin = 2395.203 uV 14:47:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 244.522 uVs 14:47:00 Integrated Voltage Measurement... 14:47:09 Voltage Offset Correction: v_off_ini = 2386.388 uV, v_off_fin = 2363.142 uV 14:47:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.082 uVs 14:47:09 Integrated Voltage Measurement... 14:47:18 Voltage Offset Correction: v_off_ini = 2374.087 uV, v_off_fin = 2383.036 uV 14:47:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.958 uVs 14:47:22 I1Y Average and RMS of Measurements VT = -236.959 +- 7.945 uVs I1Y = -47.390 +- 1.590 uTm 14:47:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:30 Integrated Voltage Measurement... 14:47:39 Voltage Offset Correction: v_off_ini = 2347.777 uV, v_off_fin = 2350.326 uV 14:47:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.936 uVs 14:47:39 Integrated Voltage Measurement... 14:47:48 Voltage Offset Correction: v_off_ini = 2358.742 uV, v_off_fin = 2387.140 uV 14:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.283 uVs 14:47:48 Integrated Voltage Measurement... 14:47:57 Voltage Offset Correction: v_off_ini = 2314.860 uV, v_off_fin = 2334.460 uV 14:47:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -52.767 uVs 14:47:57 Integrated Voltage Measurement... 14:48:06 Voltage Offset Correction: v_off_ini = 2397.627 uV, v_off_fin = 2390.507 uV 14:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.409 uVs 14:48:06 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = 2371.973 uV, v_off_fin = 2358.926 uV 14:48:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.124 uVs 14:48:15 Integrated Voltage Measurement... 14:48:24 Voltage Offset Correction: v_off_ini = 2358.885 uV, v_off_fin = 2392.657 uV 14:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.099 uVs 14:48:26 I2X Average and RMS of Measurements VT = -60.436 +- 8.585 uVs I2X = 5.560 +- 0.790 uTm^2 14:48:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:34 Integrated Voltage Measurement... 14:48:43 Voltage Offset Correction: v_off_ini = 2351.684 uV, v_off_fin = 2349.757 uV 14:48:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.773 uVs 14:48:43 Integrated Voltage Measurement... 14:48:52 Voltage Offset Correction: v_off_ini = 2376.587 uV, v_off_fin = 2373.322 uV 14:48:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.482 uVs 14:48:52 Integrated Voltage Measurement... 14:49:01 Voltage Offset Correction: v_off_ini = 2393.171 uV, v_off_fin = 2365.764 uV 14:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.931 uVs 14:49:01 Integrated Voltage Measurement... 14:49:10 Voltage Offset Correction: v_off_ini = 2382.353 uV, v_off_fin = 2363.297 uV 14:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.657 uVs 14:49:10 Integrated Voltage Measurement... 14:49:19 Voltage Offset Correction: v_off_ini = 2396.342 uV, v_off_fin = 2389.015 uV 14:49:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.238 uVs 14:49:19 Integrated Voltage Measurement... 14:49:28 Voltage Offset Correction: v_off_ini = 2345.383 uV, v_off_fin = 2359.103 uV 14:49:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 419.815 uVs 14:49:30 I2Y Average and RMS of Measurements VT = -376.316 +- 24.627 uVs I2Y = -34.621 +- 2.266 uTm^2 14:49:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:45 Integrated Voltage Measurement... 14:49:54 Voltage Offset Correction: v_off_ini = 2357.974 uV, v_off_fin = 2357.645 uV 14:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.977 uVs 14:49:54 Integrated Voltage Measurement... 14:50:03 Voltage Offset Correction: v_off_ini = 2363.174 uV, v_off_fin = 2372.420 uV 14:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.083 uVs 14:50:03 Integrated Voltage Measurement... 14:50:12 Voltage Offset Correction: v_off_ini = 2376.866 uV, v_off_fin = 2354.529 uV 14:50:12 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -68.189 uVs 14:50:12 Integrated Voltage Measurement... 14:50:21 Voltage Offset Correction: v_off_ini = 2338.335 uV, v_off_fin = 2357.442 uV 14:50:21 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 67.687 uVs 14:50:21 Integrated Voltage Measurement... 14:50:30 Voltage Offset Correction: v_off_ini = 2338.892 uV, v_off_fin = 2329.492 uV 14:50:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.788 uVs 14:50:30 Integrated Voltage Measurement... 14:50:39 Voltage Offset Correction: v_off_ini = 2337.722 uV, v_off_fin = 2338.137 uV 14:50:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.162 uVs 14:50:43 I1X Average and RMS of Measurements VT = -66.981 +- 4.564 uVs I1X = 13.398 +- 0.913 uTm 14:50:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:50 Integrated Voltage Measurement... 14:50:59 Voltage Offset Correction: v_off_ini = 2324.159 uV, v_off_fin = 2333.796 uV 14:50:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.753 uVs 14:50:59 Integrated Voltage Measurement... 14:51:08 Voltage Offset Correction: v_off_ini = 2330.277 uV, v_off_fin = 2332.915 uV 14:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 234.859 uVs 14:51:08 Integrated Voltage Measurement... 14:51:17 Voltage Offset Correction: v_off_ini = 2337.381 uV, v_off_fin = 2324.398 uV 14:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.354 uVs 14:51:17 Integrated Voltage Measurement... 14:51:26 Voltage Offset Correction: v_off_ini = 2337.169 uV, v_off_fin = 2333.674 uV 14:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.049 uVs 14:51:26 Integrated Voltage Measurement... 14:51:35 Voltage Offset Correction: v_off_ini = 2312.660 uV, v_off_fin = 2291.371 uV 14:51:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.789 uVs 14:51:35 Integrated Voltage Measurement... 14:51:44 Voltage Offset Correction: v_off_ini = 2328.011 uV, v_off_fin = 2312.403 uV 14:51:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.029 uVs 14:51:48 I1Y Average and RMS of Measurements VT = -215.139 +- 11.674 uVs I1Y = -43.025 +- 2.335 uTm 14:51:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:56 Integrated Voltage Measurement... 14:52:05 Voltage Offset Correction: v_off_ini = 2329.774 uV, v_off_fin = 2319.294 uV 14:52:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.146 uVs 14:52:05 Integrated Voltage Measurement... 14:52:14 Voltage Offset Correction: v_off_ini = 2341.707 uV, v_off_fin = 2340.542 uV 14:52:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.175 uVs 14:52:14 Integrated Voltage Measurement... 14:52:23 Voltage Offset Correction: v_off_ini = 2301.936 uV, v_off_fin = 2322.938 uV 14:52:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.121 uVs 14:52:23 Integrated Voltage Measurement... 14:52:32 Voltage Offset Correction: v_off_ini = 2327.530 uV, v_off_fin = 2350.903 uV 14:52:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.123 uVs 14:52:32 Integrated Voltage Measurement... 14:52:41 Voltage Offset Correction: v_off_ini = 2274.903 uV, v_off_fin = 2299.585 uV 14:52:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -34.740 uVs 14:52:41 Integrated Voltage Measurement... 14:52:50 Voltage Offset Correction: v_off_ini = 2326.402 uV, v_off_fin = 2354.836 uV 14:52:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.844 uVs 14:52:53 I2X Average and RMS of Measurements VT = -66.525 +- 8.986 uVs I2X = 6.120 +- 0.827 uTm^2 14:52:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:00 Integrated Voltage Measurement... 14:53:09 Voltage Offset Correction: v_off_ini = 2353.206 uV, v_off_fin = 2325.480 uV 14:53:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.819 uVs 14:53:09 Integrated Voltage Measurement... 14:53:18 Voltage Offset Correction: v_off_ini = 2320.244 uV, v_off_fin = 2334.392 uV 14:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.788 uVs 14:53:18 Integrated Voltage Measurement... 14:53:27 Voltage Offset Correction: v_off_ini = 2325.200 uV, v_off_fin = 2320.654 uV 14:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.876 uVs 14:53:27 Integrated Voltage Measurement... 14:53:36 Voltage Offset Correction: v_off_ini = 2357.847 uV, v_off_fin = 2342.651 uV 14:53:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.012 uVs 14:53:36 Integrated Voltage Measurement... 14:53:45 Voltage Offset Correction: v_off_ini = 2334.810 uV, v_off_fin = 2363.060 uV 14:53:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -383.016 uVs 14:53:45 Integrated Voltage Measurement... 14:53:54 Voltage Offset Correction: v_off_ini = 2367.941 uV, v_off_fin = 2359.980 uV 14:53:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.352 uVs 14:53:57 I2Y Average and RMS of Measurements VT = -352.477 +- 13.292 uVs I2Y = -32.428 +- 1.223 uTm^2 14:54:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:12 Integrated Voltage Measurement... 14:54:21 Voltage Offset Correction: v_off_ini = 2370.829 uV, v_off_fin = 2366.273 uV 14:54:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -66.310 uVs 14:54:21 Integrated Voltage Measurement... 14:54:30 Voltage Offset Correction: v_off_ini = 2379.979 uV, v_off_fin = 2380.596 uV 14:54:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 59.019 uVs 14:54:30 Integrated Voltage Measurement... 14:54:39 Voltage Offset Correction: v_off_ini = 2374.310 uV, v_off_fin = 2397.041 uV 14:54:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.214 uVs 14:54:39 Integrated Voltage Measurement... 14:54:48 Voltage Offset Correction: v_off_ini = 2400.700 uV, v_off_fin = 2404.433 uV 14:54:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.356 uVs 14:54:48 Integrated Voltage Measurement... 14:54:57 Voltage Offset Correction: v_off_ini = 2409.657 uV, v_off_fin = 2388.154 uV 14:54:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.761 uVs 14:54:57 Integrated Voltage Measurement... 14:55:06 Voltage Offset Correction: v_off_ini = 2380.095 uV, v_off_fin = 2382.089 uV 14:55:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.495 uVs 14:55:10 I1X Average and RMS of Measurements VT = -73.192 +- 15.158 uVs I1X = 14.640 +- 3.031 uTm 14:55:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:17 Integrated Voltage Measurement... 14:55:26 Voltage Offset Correction: v_off_ini = 2383.587 uV, v_off_fin = 2381.971 uV 14:55:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.261 uVs 14:55:26 Integrated Voltage Measurement... 14:55:35 Voltage Offset Correction: v_off_ini = 2382.452 uV, v_off_fin = 2392.002 uV 14:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.313 uVs 14:55:35 Integrated Voltage Measurement... 14:55:44 Voltage Offset Correction: v_off_ini = 2362.591 uV, v_off_fin = 2364.751 uV 14:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.337 uVs 14:55:44 Integrated Voltage Measurement... 14:55:53 Voltage Offset Correction: v_off_ini = 2377.914 uV, v_off_fin = 2365.197 uV 14:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.818 uVs 14:55:53 Integrated Voltage Measurement... 14:56:02 Voltage Offset Correction: v_off_ini = 2375.833 uV, v_off_fin = 2344.623 uV 14:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -219.074 uVs 14:56:02 Integrated Voltage Measurement... 14:56:11 Voltage Offset Correction: v_off_ini = 2345.779 uV, v_off_fin = 2377.008 uV 14:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.238 uVs 14:56:15 I1Y Average and RMS of Measurements VT = -215.507 +- 12.733 uVs I1Y = -43.100 +- 2.546 uTm 14:56:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:23 Integrated Voltage Measurement... 14:56:32 Voltage Offset Correction: v_off_ini = 2366.981 uV, v_off_fin = 2360.347 uV 14:56:32 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -61.697 uVs 14:56:32 Integrated Voltage Measurement... 14:56:41 Voltage Offset Correction: v_off_ini = 2365.182 uV, v_off_fin = 2401.441 uV 14:56:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.687 uVs 14:56:41 Integrated Voltage Measurement... 14:56:50 Voltage Offset Correction: v_off_ini = 2389.435 uV, v_off_fin = 2379.254 uV 14:56:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.642 uVs 14:56:50 Integrated Voltage Measurement... 14:56:59 Voltage Offset Correction: v_off_ini = 2397.398 uV, v_off_fin = 2423.434 uV 14:56:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.341 uVs 14:56:59 Integrated Voltage Measurement... 14:57:08 Voltage Offset Correction: v_off_ini = 2393.075 uV, v_off_fin = 2364.098 uV 14:57:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.592 uVs 14:57:08 Integrated Voltage Measurement... 14:57:17 Voltage Offset Correction: v_off_ini = 2411.499 uV, v_off_fin = 2412.807 uV 14:57:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.444 uVs 14:57:19 I2X Average and RMS of Measurements VT = -89.567 +- 11.996 uVs I2X = 8.240 +- 1.103 uTm^2 14:57:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:27 Integrated Voltage Measurement... 14:57:36 Voltage Offset Correction: v_off_ini = 2355.741 uV, v_off_fin = 2343.420 uV 14:57:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -354.508 uVs 14:57:36 Integrated Voltage Measurement... 14:57:45 Voltage Offset Correction: v_off_ini = 2376.018 uV, v_off_fin = 2349.692 uV 14:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.274 uVs 14:57:45 Integrated Voltage Measurement... 14:57:54 Voltage Offset Correction: v_off_ini = 2366.142 uV, v_off_fin = 2367.397 uV 14:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.519 uVs 14:57:54 Integrated Voltage Measurement... 14:58:03 Voltage Offset Correction: v_off_ini = 2372.248 uV, v_off_fin = 2356.173 uV 14:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.963 uVs 14:58:03 Integrated Voltage Measurement... 14:58:12 Voltage Offset Correction: v_off_ini = 2350.744 uV, v_off_fin = 2347.433 uV 14:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.747 uVs 14:58:12 Integrated Voltage Measurement... 14:58:21 Voltage Offset Correction: v_off_ini = 2367.654 uV, v_off_fin = 2356.749 uV 14:58:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.362 uVs 14:58:23 I2Y Average and RMS of Measurements VT = -346.562 +- 13.523 uVs I2Y = -31.884 +- 1.245 uTm^2 14:58:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:38 Integrated Voltage Measurement... 14:58:47 Voltage Offset Correction: v_off_ini = 2365.594 uV, v_off_fin = 2354.850 uV 14:58:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -78.136 uVs 14:58:47 Integrated Voltage Measurement... 14:58:56 Voltage Offset Correction: v_off_ini = 2348.480 uV, v_off_fin = 2362.574 uV 14:58:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.634 uVs 14:58:56 Integrated Voltage Measurement... 14:59:05 Voltage Offset Correction: v_off_ini = 2346.874 uV, v_off_fin = 2345.381 uV 14:59:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.644 uVs 14:59:06 Integrated Voltage Measurement... 14:59:14 Voltage Offset Correction: v_off_ini = 2353.127 uV, v_off_fin = 2347.015 uV 14:59:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.993 uVs 14:59:15 Integrated Voltage Measurement... 14:59:23 Voltage Offset Correction: v_off_ini = 2361.218 uV, v_off_fin = 2368.499 uV 14:59:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.257 uVs 14:59:24 Integrated Voltage Measurement... 14:59:32 Voltage Offset Correction: v_off_ini = 2350.430 uV, v_off_fin = 2339.040 uV 14:59:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.742 uVs 14:59:37 I1X Average and RMS of Measurements VT = -71.901 +- 4.702 uVs I1X = 14.381 +- 0.940 uTm 14:59:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:43 Integrated Voltage Measurement... 14:59:52 Voltage Offset Correction: v_off_ini = 2346.753 uV, v_off_fin = 2347.223 uV 14:59:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.174 uVs 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = 2359.921 uV, v_off_fin = 2374.935 uV 15:00:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.017 uVs 15:00:01 Integrated Voltage Measurement... 15:00:10 Voltage Offset Correction: v_off_ini = 2344.735 uV, v_off_fin = 2349.150 uV 15:00:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.515 uVs 15:00:10 Integrated Voltage Measurement... 15:00:19 Voltage Offset Correction: v_off_ini = 2365.162 uV, v_off_fin = 2349.810 uV 15:00:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.505 uVs 15:00:19 Integrated Voltage Measurement... 15:00:28 Voltage Offset Correction: v_off_ini = 2366.463 uV, v_off_fin = 2346.264 uV 15:00:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -172.994 uVs 15:00:28 Integrated Voltage Measurement... 15:00:37 Voltage Offset Correction: v_off_ini = 2334.991 uV, v_off_fin = 2342.182 uV 15:00:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.377 uVs 15:00:42 I1Y Average and RMS of Measurements VT = -203.597 +- 8.483 uVs I1Y = -40.715 +- 1.696 uTm 15:00:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:49 Integrated Voltage Measurement... 15:00:58 Voltage Offset Correction: v_off_ini = 2342.457 uV, v_off_fin = 2335.088 uV 15:00:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.047 uVs 15:00:58 Integrated Voltage Measurement... 15:01:07 Voltage Offset Correction: v_off_ini = 2351.442 uV, v_off_fin = 2353.678 uV 15:01:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.683 uVs 15:01:07 Integrated Voltage Measurement... 15:01:16 Voltage Offset Correction: v_off_ini = 2385.292 uV, v_off_fin = 2339.758 uV 15:01:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.375 uVs 15:01:16 Integrated Voltage Measurement... 15:01:25 Voltage Offset Correction: v_off_ini = 2362.414 uV, v_off_fin = 2376.420 uV 15:01:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.059 uVs 15:01:25 Integrated Voltage Measurement... 15:01:34 Voltage Offset Correction: v_off_ini = 2347.626 uV, v_off_fin = 2339.327 uV 15:01:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -67.416 uVs 15:01:34 Integrated Voltage Measurement... 15:01:43 Voltage Offset Correction: v_off_ini = 2333.347 uV, v_off_fin = 2358.196 uV 15:01:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.607 uVs 15:01:46 I2X Average and RMS of Measurements VT = -75.865 +- 11.877 uVs I2X = 6.980 +- 1.093 uTm^2 15:01:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:54 Integrated Voltage Measurement... 15:02:02 Voltage Offset Correction: v_off_ini = 2374.263 uV, v_off_fin = 2357.492 uV 15:02:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -331.484 uVs 15:02:03 Integrated Voltage Measurement... 15:02:12 Voltage Offset Correction: v_off_ini = 2351.557 uV, v_off_fin = 2378.890 uV 15:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.590 uVs 15:02:12 Integrated Voltage Measurement... 15:02:21 Voltage Offset Correction: v_off_ini = 2368.661 uV, v_off_fin = 2369.201 uV 15:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.612 uVs 15:02:21 Integrated Voltage Measurement... 15:02:30 Voltage Offset Correction: v_off_ini = 2366.491 uV, v_off_fin = 2370.807 uV 15:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.250 uVs 15:02:30 Integrated Voltage Measurement... 15:02:39 Voltage Offset Correction: v_off_ini = 2382.449 uV, v_off_fin = 2381.893 uV 15:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.725 uVs 15:02:39 Integrated Voltage Measurement... 15:02:48 Voltage Offset Correction: v_off_ini = 2369.055 uV, v_off_fin = 2397.232 uV 15:02:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.232 uVs 15:02:50 I2Y Average and RMS of Measurements VT = -333.482 +- 13.398 uVs I2Y = -30.681 +- 1.233 uTm^2 15:03:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:05 Integrated Voltage Measurement... 15:03:14 Voltage Offset Correction: v_off_ini = 2383.035 uV, v_off_fin = 2355.126 uV 15:03:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -72.424 uVs 15:03:14 Integrated Voltage Measurement... 15:03:23 Voltage Offset Correction: v_off_ini = 2376.061 uV, v_off_fin = 2376.618 uV 15:03:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.224 uVs 15:03:23 Integrated Voltage Measurement... 15:03:32 Voltage Offset Correction: v_off_ini = 2390.888 uV, v_off_fin = 2391.817 uV 15:03:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.759 uVs 15:03:32 Integrated Voltage Measurement... 15:03:41 Voltage Offset Correction: v_off_ini = 2375.483 uV, v_off_fin = 2376.314 uV 15:03:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.391 uVs 15:03:41 Integrated Voltage Measurement... 15:03:50 Voltage Offset Correction: v_off_ini = 2380.302 uV, v_off_fin = 2378.913 uV 15:03:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.463 uVs 15:03:50 Integrated Voltage Measurement... 15:03:59 Voltage Offset Correction: v_off_ini = 2370.096 uV, v_off_fin = 2354.812 uV 15:03:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.917 uVs 15:04:03 I1X Average and RMS of Measurements VT = -73.363 +- 3.624 uVs I1X = 14.673 +- 0.724 uTm 15:04:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:10 Integrated Voltage Measurement... 15:04:19 Voltage Offset Correction: v_off_ini = 2400.802 uV, v_off_fin = 2392.517 uV 15:04:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.050 uVs 15:04:19 Integrated Voltage Measurement... 15:04:28 Voltage Offset Correction: v_off_ini = 2399.902 uV, v_off_fin = 2417.798 uV 15:04:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.317 uVs 15:04:28 Integrated Voltage Measurement... 15:04:37 Voltage Offset Correction: v_off_ini = 2387.836 uV, v_off_fin = 2373.768 uV 15:04:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.360 uVs 15:04:37 Integrated Voltage Measurement... 15:04:46 Voltage Offset Correction: v_off_ini = 2359.889 uV, v_off_fin = 2381.041 uV 15:04:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.653 uVs 15:04:46 Integrated Voltage Measurement... 15:04:55 Voltage Offset Correction: v_off_ini = 2398.838 uV, v_off_fin = 2373.221 uV 15:04:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.640 uVs 15:04:55 Integrated Voltage Measurement... 15:05:04 Voltage Offset Correction: v_off_ini = 2370.670 uV, v_off_fin = 2371.956 uV 15:05:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.442 uVs 15:05:08 I1Y Average and RMS of Measurements VT = -197.577 +- 3.874 uVs I1Y = -39.512 +- 0.776 uTm 15:05:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:16 Integrated Voltage Measurement... 15:05:25 Voltage Offset Correction: v_off_ini = 2328.545 uV, v_off_fin = 2309.514 uV 15:05:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.861 uVs 15:05:25 Integrated Voltage Measurement... 15:05:34 Voltage Offset Correction: v_off_ini = 2332.598 uV, v_off_fin = 2346.064 uV 15:05:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.285 uVs 15:05:34 Integrated Voltage Measurement... 15:05:43 Voltage Offset Correction: v_off_ini = 2327.513 uV, v_off_fin = 2341.415 uV 15:05:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.903 uVs 15:05:43 Integrated Voltage Measurement... 15:05:52 Voltage Offset Correction: v_off_ini = 2379.087 uV, v_off_fin = 2351.552 uV 15:05:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.874 uVs 15:05:52 Integrated Voltage Measurement... 15:06:01 Voltage Offset Correction: v_off_ini = 2341.529 uV, v_off_fin = 2311.931 uV 15:06:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.663 uVs 15:06:01 Integrated Voltage Measurement... 15:06:10 Voltage Offset Correction: v_off_ini = 2329.380 uV, v_off_fin = 2333.591 uV 15:06:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.515 uVs 15:06:12 I2X Average and RMS of Measurements VT = -76.184 +- 13.636 uVs I2X = 7.009 +- 1.255 uTm^2 15:06:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:20 Integrated Voltage Measurement... 15:06:29 Voltage Offset Correction: v_off_ini = 2329.930 uV, v_off_fin = 2353.006 uV 15:06:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.443 uVs 15:06:29 Integrated Voltage Measurement... 15:06:38 Voltage Offset Correction: v_off_ini = 2371.546 uV, v_off_fin = 2368.058 uV 15:06:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.987 uVs 15:06:38 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 2360.962 uV, v_off_fin = 2357.838 uV 15:06:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -344.313 uVs 15:06:47 Integrated Voltage Measurement... 15:06:56 Voltage Offset Correction: v_off_ini = 2347.794 uV, v_off_fin = 2371.977 uV 15:06:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.551 uVs 15:06:56 Integrated Voltage Measurement... 15:07:05 Voltage Offset Correction: v_off_ini = 2357.174 uV, v_off_fin = 2355.277 uV 15:07:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.246 uVs 15:07:05 Integrated Voltage Measurement... 15:07:14 Voltage Offset Correction: v_off_ini = 2364.855 uV, v_off_fin = 2323.243 uV 15:07:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.660 uVs 15:07:17 I2Y Average and RMS of Measurements VT = -325.367 +- 9.123 uVs I2Y = -29.934 +- 0.839 uTm^2 15:07:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:32 Integrated Voltage Measurement... 15:07:41 Voltage Offset Correction: v_off_ini = 2361.258 uV, v_off_fin = 2354.430 uV 15:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.347 uVs 15:07:41 Integrated Voltage Measurement... 15:07:50 Voltage Offset Correction: v_off_ini = 2357.503 uV, v_off_fin = 2379.619 uV 15:07:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.890 uVs 15:07:50 Integrated Voltage Measurement... 15:07:59 Voltage Offset Correction: v_off_ini = 2358.116 uV, v_off_fin = 2381.786 uV 15:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.014 uVs 15:07:59 Integrated Voltage Measurement... 15:08:08 Voltage Offset Correction: v_off_ini = 2357.378 uV, v_off_fin = 2344.367 uV 15:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.908 uVs 15:08:08 Integrated Voltage Measurement... 15:08:17 Voltage Offset Correction: v_off_ini = 2365.232 uV, v_off_fin = 2344.873 uV 15:08:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.186 uVs 15:08:17 Integrated Voltage Measurement... 15:08:26 Voltage Offset Correction: v_off_ini = 2371.133 uV, v_off_fin = 2360.352 uV 15:08:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.034 uVs 15:08:30 I1X Average and RMS of Measurements VT = -78.397 +- 8.348 uVs I1X = 15.680 +- 1.670 uTm 15:08:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:37 Integrated Voltage Measurement... 15:08:46 Voltage Offset Correction: v_off_ini = 2369.248 uV, v_off_fin = 2364.493 uV 15:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.353 uVs 15:08:46 Integrated Voltage Measurement... 15:08:55 Voltage Offset Correction: v_off_ini = 2379.534 uV, v_off_fin = 2380.440 uV 15:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.396 uVs 15:08:55 Integrated Voltage Measurement... 15:09:04 Voltage Offset Correction: v_off_ini = 2345.395 uV, v_off_fin = 2352.276 uV 15:09:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.286 uVs 15:09:04 Integrated Voltage Measurement... 15:09:13 Voltage Offset Correction: v_off_ini = 2358.454 uV, v_off_fin = 2374.751 uV 15:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.344 uVs 15:09:13 Integrated Voltage Measurement... 15:09:22 Voltage Offset Correction: v_off_ini = 2374.354 uV, v_off_fin = 2362.842 uV 15:09:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.033 uVs 15:09:22 Integrated Voltage Measurement... 15:09:31 Voltage Offset Correction: v_off_ini = 2352.573 uV, v_off_fin = 2381.066 uV 15:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.852 uVs 15:09:35 I1Y Average and RMS of Measurements VT = -202.877 +- 4.578 uVs I1Y = -40.573 +- 0.914 uTm 15:09:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:09:43 Integrated Voltage Measurement... 15:09:52 Voltage Offset Correction: v_off_ini = 2357.309 uV, v_off_fin = 2353.111 uV 15:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.235 uVs 15:09:52 Integrated Voltage Measurement... 15:10:01 Voltage Offset Correction: v_off_ini = 2309.011 uV, v_off_fin = 2336.169 uV 15:10:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.262 uVs 15:10:01 Integrated Voltage Measurement... 15:10:10 Voltage Offset Correction: v_off_ini = 2330.052 uV, v_off_fin = 2319.328 uV 15:10:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.041 uVs 15:10:10 Integrated Voltage Measurement... 15:10:19 Voltage Offset Correction: v_off_ini = 2328.080 uV, v_off_fin = 2318.587 uV 15:10:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.815 uVs 15:10:19 Integrated Voltage Measurement... 15:10:28 Voltage Offset Correction: v_off_ini = 2322.981 uV, v_off_fin = 2324.623 uV 15:10:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.681 uVs 15:10:28 Integrated Voltage Measurement... 15:10:37 Voltage Offset Correction: v_off_ini = 2310.784 uV, v_off_fin = 2320.505 uV 15:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.172 uVs 15:10:39 I2X Average and RMS of Measurements VT = -76.701 +- 13.638 uVs I2X = 7.056 +- 1.255 uTm^2 15:10:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:47 Integrated Voltage Measurement... 15:10:56 Voltage Offset Correction: v_off_ini = 2353.935 uV, v_off_fin = 2334.936 uV 15:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.070 uVs 15:10:56 Integrated Voltage Measurement... 15:11:05 Voltage Offset Correction: v_off_ini = 2328.878 uV, v_off_fin = 2316.084 uV 15:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.196 uVs 15:11:05 Integrated Voltage Measurement... 15:11:14 Voltage Offset Correction: v_off_ini = 2299.044 uV, v_off_fin = 2287.106 uV 15:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.801 uVs 15:11:14 Integrated Voltage Measurement... 15:11:23 Voltage Offset Correction: v_off_ini = 2310.417 uV, v_off_fin = 2305.021 uV 15:11:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.258 uVs 15:11:23 Integrated Voltage Measurement... 15:11:32 Voltage Offset Correction: v_off_ini = 2319.723 uV, v_off_fin = 2313.117 uV 15:11:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.729 uVs 15:11:32 Integrated Voltage Measurement... 15:11:41 Voltage Offset Correction: v_off_ini = 2307.557 uV, v_off_fin = 2304.813 uV 15:11:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 288.317 uVs 15:11:43 I2Y Average and RMS of Measurements VT = -301.228 +- 16.093 uVs I2Y = -27.713 +- 1.481 uTm^2 15:11:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:58 Integrated Voltage Measurement... 15:12:07 Voltage Offset Correction: v_off_ini = 2323.228 uV, v_off_fin = 2291.838 uV 15:12:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.217 uVs 15:12:07 Integrated Voltage Measurement... 15:12:16 Voltage Offset Correction: v_off_ini = 2316.654 uV, v_off_fin = 2319.332 uV 15:12:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.419 uVs 15:12:16 Integrated Voltage Measurement... 15:12:25 Voltage Offset Correction: v_off_ini = 2303.834 uV, v_off_fin = 2312.500 uV 15:12:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.430 uVs 15:12:25 Integrated Voltage Measurement... 15:12:34 Voltage Offset Correction: v_off_ini = 2318.521 uV, v_off_fin = 2329.976 uV 15:12:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.004 uVs 15:12:34 Integrated Voltage Measurement... 15:12:43 Voltage Offset Correction: v_off_ini = 2324.078 uV, v_off_fin = 2304.039 uV 15:12:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.532 uVs 15:12:43 Integrated Voltage Measurement... 15:12:52 Voltage Offset Correction: v_off_ini = 2313.807 uV, v_off_fin = 2310.365 uV 15:12:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.374 uVs 15:12:57 I1X Average and RMS of Measurements VT = -67.829 +- 3.017 uVs I1X = 13.566 +- 0.603 uTm 15:12:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:03 Integrated Voltage Measurement... 15:13:12 Voltage Offset Correction: v_off_ini = 2330.276 uV, v_off_fin = 2322.370 uV 15:13:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -182.926 uVs 15:13:12 Integrated Voltage Measurement... 15:13:21 Voltage Offset Correction: v_off_ini = 2326.905 uV, v_off_fin = 2362.072 uV 15:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.340 uVs 15:13:21 Integrated Voltage Measurement... 15:13:30 Voltage Offset Correction: v_off_ini = 2325.185 uV, v_off_fin = 2300.474 uV 15:13:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.446 uVs 15:13:30 Integrated Voltage Measurement... 15:13:39 Voltage Offset Correction: v_off_ini = 2301.867 uV, v_off_fin = 2325.375 uV 15:13:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.296 uVs 15:13:39 Integrated Voltage Measurement... 15:13:48 Voltage Offset Correction: v_off_ini = 2321.344 uV, v_off_fin = 2321.298 uV 15:13:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.536 uVs 15:13:48 Integrated Voltage Measurement... 15:13:57 Voltage Offset Correction: v_off_ini = 2322.910 uV, v_off_fin = 2333.397 uV 15:13:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.414 uVs 15:14:01 I1Y Average and RMS of Measurements VT = -193.326 +- 4.689 uVs I1Y = -38.665 +- 0.937 uTm 15:14:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:09 Integrated Voltage Measurement... 15:14:18 Voltage Offset Correction: v_off_ini = 2330.379 uV, v_off_fin = 2305.671 uV 15:14:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.043 uVs 15:14:18 Integrated Voltage Measurement... 15:14:27 Voltage Offset Correction: v_off_ini = 2314.650 uV, v_off_fin = 2354.806 uV 15:14:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.969 uVs 15:14:27 Integrated Voltage Measurement... 15:14:36 Voltage Offset Correction: v_off_ini = 2342.617 uV, v_off_fin = 2301.817 uV 15:14:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -55.004 uVs 15:14:36 Integrated Voltage Measurement... 15:14:45 Voltage Offset Correction: v_off_ini = 2324.224 uV, v_off_fin = 2311.092 uV 15:14:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.401 uVs 15:14:45 Integrated Voltage Measurement... 15:14:54 Voltage Offset Correction: v_off_ini = 2335.464 uV, v_off_fin = 2313.712 uV 15:14:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.389 uVs 15:14:54 Integrated Voltage Measurement... 15:15:03 Voltage Offset Correction: v_off_ini = 2314.901 uV, v_off_fin = 2325.289 uV 15:15:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.336 uVs 15:15:06 I2X Average and RMS of Measurements VT = -87.524 +- 8.366 uVs I2X = 8.053 +- 0.770 uTm^2 15:15:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:13 Integrated Voltage Measurement... 15:15:22 Voltage Offset Correction: v_off_ini = 2341.633 uV, v_off_fin = 2337.754 uV 15:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.459 uVs 15:15:22 Integrated Voltage Measurement... 15:15:31 Voltage Offset Correction: v_off_ini = 2325.269 uV, v_off_fin = 2351.981 uV 15:15:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.145 uVs 15:15:31 Integrated Voltage Measurement... 15:15:40 Voltage Offset Correction: v_off_ini = 2350.769 uV, v_off_fin = 2343.169 uV 15:15:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.335 uVs 15:15:40 Integrated Voltage Measurement... 15:15:49 Voltage Offset Correction: v_off_ini = 2362.671 uV, v_off_fin = 2336.732 uV 15:15:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.658 uVs 15:15:49 Integrated Voltage Measurement... 15:15:58 Voltage Offset Correction: v_off_ini = 2353.978 uV, v_off_fin = 2342.476 uV 15:15:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.243 uVs 15:15:59 Integrated Voltage Measurement... 15:16:07 Voltage Offset Correction: v_off_ini = 2339.643 uV, v_off_fin = 2354.101 uV 15:16:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.596 uVs 15:16:10 I2Y Average and RMS of Measurements VT = -297.739 +- 2.381 uVs I2Y = -27.392 +- 0.219 uTm^2 15:16:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:25 Integrated Voltage Measurement... 15:16:34 Voltage Offset Correction: v_off_ini = 2353.942 uV, v_off_fin = 2346.527 uV 15:16:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.070 uVs 15:16:34 Integrated Voltage Measurement... 15:16:43 Voltage Offset Correction: v_off_ini = 2362.151 uV, v_off_fin = 2367.615 uV 15:16:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.383 uVs 15:16:43 Integrated Voltage Measurement... 15:16:52 Voltage Offset Correction: v_off_ini = 2347.432 uV, v_off_fin = 2330.647 uV 15:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.272 uVs 15:16:52 Integrated Voltage Measurement... 15:17:01 Voltage Offset Correction: v_off_ini = 2351.217 uV, v_off_fin = 2355.035 uV 15:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.729 uVs 15:17:01 Integrated Voltage Measurement... 15:17:10 Voltage Offset Correction: v_off_ini = 2360.553 uV, v_off_fin = 2361.414 uV 15:17:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.957 uVs 15:17:10 Integrated Voltage Measurement... 15:17:19 Voltage Offset Correction: v_off_ini = 2359.187 uV, v_off_fin = 2342.483 uV 15:17:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.659 uVs 15:17:23 I1X Average and RMS of Measurements VT = -66.845 +- 15.688 uVs I1X = 13.369 +- 3.138 uTm 15:17:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:30 Integrated Voltage Measurement... 15:17:39 Voltage Offset Correction: v_off_ini = 2340.527 uV, v_off_fin = 2325.209 uV 15:17:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.903 uVs 15:17:39 Integrated Voltage Measurement... 15:17:48 Voltage Offset Correction: v_off_ini = 2313.796 uV, v_off_fin = 2323.598 uV 15:17:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.204 uVs 15:17:48 Integrated Voltage Measurement... 15:17:57 Voltage Offset Correction: v_off_ini = 2333.120 uV, v_off_fin = 2316.050 uV 15:17:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.385 uVs 15:17:57 Integrated Voltage Measurement... 15:18:06 Voltage Offset Correction: v_off_ini = 2310.422 uV, v_off_fin = 2347.294 uV 15:18:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.181 uVs 15:18:06 Integrated Voltage Measurement... 15:18:15 Voltage Offset Correction: v_off_ini = 2322.376 uV, v_off_fin = 2295.356 uV 15:18:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.212 uVs 15:18:15 Integrated Voltage Measurement... 15:18:24 Voltage Offset Correction: v_off_ini = 2335.590 uV, v_off_fin = 2320.680 uV 15:18:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.263 uVs 15:18:28 I1Y Average and RMS of Measurements VT = -186.858 +- 5.535 uVs I1Y = -37.368 +- 1.107 uTm 15:18:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:36 Integrated Voltage Measurement... 15:18:45 Voltage Offset Correction: v_off_ini = 2330.827 uV, v_off_fin = 2316.335 uV 15:18:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.261 uVs 15:18:45 Integrated Voltage Measurement... 15:18:54 Voltage Offset Correction: v_off_ini = 2349.689 uV, v_off_fin = 2335.077 uV 15:18:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.659 uVs 15:18:54 Integrated Voltage Measurement... 15:19:03 Voltage Offset Correction: v_off_ini = 2314.223 uV, v_off_fin = 2322.751 uV 15:19:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -89.632 uVs 15:19:03 Integrated Voltage Measurement... 15:19:12 Voltage Offset Correction: v_off_ini = 2299.833 uV, v_off_fin = 2279.902 uV 15:19:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.773 uVs 15:19:12 Integrated Voltage Measurement... 15:19:21 Voltage Offset Correction: v_off_ini = 2290.022 uV, v_off_fin = 2298.458 uV 15:19:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.803 uVs 15:19:21 Integrated Voltage Measurement... 15:19:30 Voltage Offset Correction: v_off_ini = 2303.797 uV, v_off_fin = 2292.233 uV 15:19:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.208 uVs 15:19:32 I2X Average and RMS of Measurements VT = -77.556 +- 13.540 uVs I2X = 7.136 +- 1.246 uTm^2 15:19:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:40 Integrated Voltage Measurement... 15:19:49 Voltage Offset Correction: v_off_ini = 2285.347 uV, v_off_fin = 2276.441 uV 15:19:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.949 uVs 15:19:49 Integrated Voltage Measurement... 15:19:58 Voltage Offset Correction: v_off_ini = 2297.501 uV, v_off_fin = 2291.042 uV 15:19:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.601 uVs 15:19:58 Integrated Voltage Measurement... 15:20:07 Voltage Offset Correction: v_off_ini = 2270.101 uV, v_off_fin = 2280.514 uV 15:20:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.505 uVs 15:20:07 Integrated Voltage Measurement... 15:20:16 Voltage Offset Correction: v_off_ini = 2275.857 uV, v_off_fin = 2296.241 uV 15:20:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.369 uVs 15:20:16 Integrated Voltage Measurement... 15:20:25 Voltage Offset Correction: v_off_ini = 2291.743 uV, v_off_fin = 2298.881 uV 15:20:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.870 uVs 15:20:25 Integrated Voltage Measurement... 15:20:34 Voltage Offset Correction: v_off_ini = 2307.211 uV, v_off_fin = 2298.129 uV 15:20:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.789 uVs 15:20:37 I2Y Average and RMS of Measurements VT = -291.680 +- 6.263 uVs I2Y = -26.835 +- 0.576 uTm^2 15:20:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:52 Integrated Voltage Measurement... 15:21:01 Voltage Offset Correction: v_off_ini = 2297.932 uV, v_off_fin = 2296.106 uV 15:21:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.841 uVs 15:21:01 Integrated Voltage Measurement... 15:21:10 Voltage Offset Correction: v_off_ini = 2260.273 uV, v_off_fin = 2274.529 uV 15:21:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.148 uVs 15:21:10 Integrated Voltage Measurement... 15:21:19 Voltage Offset Correction: v_off_ini = 2281.077 uV, v_off_fin = 2277.803 uV 15:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.669 uVs 15:21:19 Integrated Voltage Measurement... 15:21:28 Voltage Offset Correction: v_off_ini = 2266.150 uV, v_off_fin = 2262.377 uV 15:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.531 uVs 15:21:28 Integrated Voltage Measurement... 15:21:37 Voltage Offset Correction: v_off_ini = 2290.633 uV, v_off_fin = 2305.403 uV 15:21:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.196 uVs 15:21:37 Integrated Voltage Measurement... 15:21:46 Voltage Offset Correction: v_off_ini = 2317.672 uV, v_off_fin = 2306.778 uV 15:21:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.336 uVs 15:21:50 I1X Average and RMS of Measurements VT = -78.454 +- 5.997 uVs I1X = 15.691 +- 1.199 uTm 15:21:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:21:57 Integrated Voltage Measurement... 15:22:05 Voltage Offset Correction: v_off_ini = 2286.154 uV, v_off_fin = 2283.594 uV 15:22:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.564 uVs 15:22:06 Integrated Voltage Measurement... 15:22:14 Voltage Offset Correction: v_off_ini = 2284.778 uV, v_off_fin = 2303.703 uV 15:22:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.035 uVs 15:22:15 Integrated Voltage Measurement... 15:22:23 Voltage Offset Correction: v_off_ini = 2302.505 uV, v_off_fin = 2278.223 uV 15:22:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.677 uVs 15:22:24 Integrated Voltage Measurement... 15:22:32 Voltage Offset Correction: v_off_ini = 2281.465 uV, v_off_fin = 2312.738 uV 15:22:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.513 uVs 15:22:33 Integrated Voltage Measurement... 15:22:41 Voltage Offset Correction: v_off_ini = 2282.673 uV, v_off_fin = 2295.700 uV 15:22:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.818 uVs 15:22:42 Integrated Voltage Measurement... 15:22:50 Voltage Offset Correction: v_off_ini = 2294.188 uV, v_off_fin = 2295.867 uV 15:22:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.129 uVs 15:22:55 I1Y Average and RMS of Measurements VT = -174.289 +- 6.860 uVs I1Y = -34.854 +- 1.372 uTm 15:23:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:23:02 Integrated Voltage Measurement... 15:23:11 Voltage Offset Correction: v_off_ini = 2275.409 uV, v_off_fin = 2272.313 uV 15:23:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -67.543 uVs 15:23:11 Integrated Voltage Measurement... 15:23:20 Voltage Offset Correction: v_off_ini = 2270.091 uV, v_off_fin = 2293.135 uV 15:23:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.145 uVs 15:23:20 Integrated Voltage Measurement... 15:23:29 Voltage Offset Correction: v_off_ini = 2280.741 uV, v_off_fin = 2269.201 uV 15:23:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.562 uVs 15:23:29 Integrated Voltage Measurement... 15:23:38 Voltage Offset Correction: v_off_ini = 2301.459 uV, v_off_fin = 2297.771 uV 15:23:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.927 uVs 15:23:38 Integrated Voltage Measurement... 15:23:47 Voltage Offset Correction: v_off_ini = 2281.539 uV, v_off_fin = 2260.085 uV 15:23:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -76.554 uVs 15:23:48 Integrated Voltage Measurement... 15:23:56 Voltage Offset Correction: v_off_ini = 2281.418 uV, v_off_fin = 2286.917 uV 15:23:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.974 uVs 15:23:59 I2X Average and RMS of Measurements VT = -78.451 +- 5.929 uVs I2X = 7.218 +- 0.546 uTm^2 15:24:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:24:07 Integrated Voltage Measurement... 15:24:16 Voltage Offset Correction: v_off_ini = 2287.215 uV, v_off_fin = 2302.916 uV 15:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.445 uVs 15:24:16 Integrated Voltage Measurement... 15:24:25 Voltage Offset Correction: v_off_ini = 2304.718 uV, v_off_fin = 2307.027 uV 15:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.110 uVs 15:24:25 Integrated Voltage Measurement... 15:24:34 Voltage Offset Correction: v_off_ini = 2301.351 uV, v_off_fin = 2288.912 uV 15:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.708 uVs 15:24:34 Integrated Voltage Measurement... 15:24:43 Voltage Offset Correction: v_off_ini = 2316.601 uV, v_off_fin = 2303.264 uV 15:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.346 uVs 15:24:43 Integrated Voltage Measurement... 15:24:52 Voltage Offset Correction: v_off_ini = 2293.154 uV, v_off_fin = 2293.350 uV 15:24:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.125 uVs 15:24:52 Integrated Voltage Measurement... 15:25:01 Voltage Offset Correction: v_off_ini = 2333.984 uV, v_off_fin = 2323.470 uV 15:25:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.540 uVs 15:25:03 I2Y Average and RMS of Measurements VT = -290.712 +- 3.697 uVs I2Y = -26.746 +- 0.340 uTm^2 15:25:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:18 Integrated Voltage Measurement... 15:25:27 Voltage Offset Correction: v_off_ini = 2292.989 uV, v_off_fin = 2264.063 uV 15:25:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.953 uVs 15:25:27 Integrated Voltage Measurement... 15:25:36 Voltage Offset Correction: v_off_ini = 2283.224 uV, v_off_fin = 2279.759 uV 15:25:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.734 uVs 15:25:36 Integrated Voltage Measurement... 15:25:45 Voltage Offset Correction: v_off_ini = 2274.784 uV, v_off_fin = 2246.714 uV 15:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.612 uVs 15:25:45 Integrated Voltage Measurement... 15:25:54 Voltage Offset Correction: v_off_ini = 2278.055 uV, v_off_fin = 2273.223 uV 15:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.379 uVs 15:25:54 Integrated Voltage Measurement... 15:26:03 Voltage Offset Correction: v_off_ini = 2270.335 uV, v_off_fin = 2286.976 uV 15:26:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.312 uVs 15:26:03 Integrated Voltage Measurement... 15:26:12 Voltage Offset Correction: v_off_ini = 2284.515 uV, v_off_fin = 2270.436 uV 15:26:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.071 uVs 15:26:16 I1X Average and RMS of Measurements VT = -80.844 +- 14.618 uVs I1X = 16.169 +- 2.924 uTm 15:26:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:23 Integrated Voltage Measurement... 15:26:32 Voltage Offset Correction: v_off_ini = 2259.788 uV, v_off_fin = 2267.391 uV 15:26:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.609 uVs 15:26:32 Integrated Voltage Measurement... 15:26:41 Voltage Offset Correction: v_off_ini = 2255.935 uV, v_off_fin = 2273.043 uV 15:26:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.751 uVs 15:26:41 Integrated Voltage Measurement... 15:26:50 Voltage Offset Correction: v_off_ini = 2272.726 uV, v_off_fin = 2247.537 uV 15:26:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.883 uVs 15:26:50 Integrated Voltage Measurement... 15:26:59 Voltage Offset Correction: v_off_ini = 2236.403 uV, v_off_fin = 2263.441 uV 15:26:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 170.421 uVs 15:26:59 Integrated Voltage Measurement... 15:27:08 Voltage Offset Correction: v_off_ini = 2271.370 uV, v_off_fin = 2262.354 uV 15:27:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.582 uVs 15:27:08 Integrated Voltage Measurement... 15:27:17 Voltage Offset Correction: v_off_ini = 2249.533 uV, v_off_fin = 2277.661 uV 15:27:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.260 uVs 15:27:21 I1Y Average and RMS of Measurements VT = -180.084 +- 8.096 uVs I1Y = -36.016 +- 1.620 uTm 15:27:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:29 Integrated Voltage Measurement... 15:27:38 Voltage Offset Correction: v_off_ini = 2262.466 uV, v_off_fin = 2253.321 uV 15:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.473 uVs 15:27:38 Integrated Voltage Measurement... 15:27:47 Voltage Offset Correction: v_off_ini = 2263.466 uV, v_off_fin = 2268.261 uV 15:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.276 uVs 15:27:47 Integrated Voltage Measurement... 15:27:56 Voltage Offset Correction: v_off_ini = 2250.200 uV, v_off_fin = 2268.347 uV 15:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.086 uVs 15:27:56 Integrated Voltage Measurement... 15:28:05 Voltage Offset Correction: v_off_ini = 2248.777 uV, v_off_fin = 2278.128 uV 15:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.837 uVs 15:28:05 Integrated Voltage Measurement... 15:28:14 Voltage Offset Correction: v_off_ini = 2234.051 uV, v_off_fin = 2235.267 uV 15:28:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.923 uVs 15:28:14 Integrated Voltage Measurement... 15:28:23 Voltage Offset Correction: v_off_ini = 2240.972 uV, v_off_fin = 2239.735 uV 15:28:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.173 uVs 15:28:25 I2X Average and RMS of Measurements VT = -80.461 +- 13.484 uVs I2X = 7.403 +- 1.240 uTm^2 15:28:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:33 Integrated Voltage Measurement... 15:28:42 Voltage Offset Correction: v_off_ini = 2237.737 uV, v_off_fin = 2220.821 uV 15:28:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -263.209 uVs 15:28:42 Integrated Voltage Measurement... 15:28:51 Voltage Offset Correction: v_off_ini = 2241.515 uV, v_off_fin = 2239.285 uV 15:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.260 uVs 15:28:51 Integrated Voltage Measurement... 15:29:00 Voltage Offset Correction: v_off_ini = 2240.565 uV, v_off_fin = 2236.898 uV 15:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.738 uVs 15:29:00 Integrated Voltage Measurement... 15:29:09 Voltage Offset Correction: v_off_ini = 2219.411 uV, v_off_fin = 2217.180 uV 15:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.250 uVs 15:29:09 Integrated Voltage Measurement... 15:29:18 Voltage Offset Correction: v_off_ini = 2230.583 uV, v_off_fin = 2224.529 uV 15:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.228 uVs 15:29:18 Integrated Voltage Measurement... 15:29:27 Voltage Offset Correction: v_off_ini = 2214.664 uV, v_off_fin = 2205.740 uV 15:29:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.237 uVs 15:29:30 I2Y Average and RMS of Measurements VT = -280.820 +- 16.335 uVs I2Y = -25.836 +- 1.502 uTm^2 15:29:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:29:46 Integrated Voltage Measurement... 15:29:55 Voltage Offset Correction: v_off_ini = 2229.290 uV, v_off_fin = 2197.725 uV 15:29:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.309 uVs 15:29:55 Integrated Voltage Measurement... 15:30:04 Voltage Offset Correction: v_off_ini = 2221.788 uV, v_off_fin = 2241.920 uV 15:30:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.739 uVs 15:30:04 Integrated Voltage Measurement... 15:30:13 Voltage Offset Correction: v_off_ini = 2227.657 uV, v_off_fin = 2205.665 uV 15:30:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.583 uVs 15:30:13 Integrated Voltage Measurement... 15:30:22 Voltage Offset Correction: v_off_ini = 2226.728 uV, v_off_fin = 2210.958 uV 15:30:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.236 uVs 15:30:22 Integrated Voltage Measurement... 15:30:31 Voltage Offset Correction: v_off_ini = 2236.360 uV, v_off_fin = 2232.134 uV 15:30:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -74.940 uVs 15:30:31 Integrated Voltage Measurement... 15:30:40 Voltage Offset Correction: v_off_ini = 2251.282 uV, v_off_fin = 2237.911 uV 15:30:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.541 uVs 15:30:44 I1X Average and RMS of Measurements VT = -72.058 +- 14.433 uVs I1X = 14.412 +- 2.886 uTm 15:30:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:51 Integrated Voltage Measurement... 15:31:00 Voltage Offset Correction: v_off_ini = 2203.790 uV, v_off_fin = 2214.596 uV 15:31:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -136.464 uVs 15:31:00 Integrated Voltage Measurement... 15:31:09 Voltage Offset Correction: v_off_ini = 2207.967 uV, v_off_fin = 2270.352 uV 15:31:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.234 uVs 15:31:09 Integrated Voltage Measurement... 15:31:18 Voltage Offset Correction: v_off_ini = 2283.150 uV, v_off_fin = 2250.689 uV 15:31:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.553 uVs 15:31:18 Integrated Voltage Measurement... 15:31:27 Voltage Offset Correction: v_off_ini = 2248.848 uV, v_off_fin = 2274.971 uV 15:31:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.715 uVs 15:31:27 Integrated Voltage Measurement... 15:31:36 Voltage Offset Correction: v_off_ini = 2270.714 uV, v_off_fin = 2272.864 uV 15:31:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.543 uVs 15:31:36 Integrated Voltage Measurement... 15:31:45 Voltage Offset Correction: v_off_ini = 2298.540 uV, v_off_fin = 2305.075 uV 15:31:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.090 uVs 15:31:49 I1Y Average and RMS of Measurements VT = -174.267 +- 4.208 uVs I1Y = -34.851 +- 0.840 uTm 15:31:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:57 Integrated Voltage Measurement... 15:32:06 Voltage Offset Correction: v_off_ini = 2271.252 uV, v_off_fin = 2271.015 uV 15:32:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.839 uVs 15:32:06 Integrated Voltage Measurement... 15:32:15 Voltage Offset Correction: v_off_ini = 2293.125 uV, v_off_fin = 2300.816 uV 15:32:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.520 uVs 15:32:15 Integrated Voltage Measurement... 15:32:24 Voltage Offset Correction: v_off_ini = 2292.925 uV, v_off_fin = 2288.660 uV 15:32:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.780 uVs 15:32:24 Integrated Voltage Measurement... 15:32:33 Voltage Offset Correction: v_off_ini = 2266.165 uV, v_off_fin = 2281.420 uV 15:32:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.355 uVs 15:32:33 Integrated Voltage Measurement... 15:32:42 Voltage Offset Correction: v_off_ini = 2302.444 uV, v_off_fin = 2295.984 uV 15:32:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.556 uVs 15:32:42 Integrated Voltage Measurement... 15:32:51 Voltage Offset Correction: v_off_ini = 2338.388 uV, v_off_fin = 2336.850 uV 15:32:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.809 uVs 15:32:53 I2X Average and RMS of Measurements VT = -74.143 +- 4.405 uVs I2X = 6.821 +- 0.405 uTm^2 15:32:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:01 Integrated Voltage Measurement... 15:33:10 Voltage Offset Correction: v_off_ini = 2336.649 uV, v_off_fin = 2322.427 uV 15:33:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -275.139 uVs 15:33:10 Integrated Voltage Measurement... 15:33:19 Voltage Offset Correction: v_off_ini = 2309.236 uV, v_off_fin = 2323.300 uV 15:33:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.724 uVs 15:33:19 Integrated Voltage Measurement... 15:33:28 Voltage Offset Correction: v_off_ini = 2322.733 uV, v_off_fin = 2305.419 uV 15:33:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.329 uVs 15:33:28 Integrated Voltage Measurement... 15:33:37 Voltage Offset Correction: v_off_ini = 2281.085 uV, v_off_fin = 2304.071 uV 15:33:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.065 uVs 15:33:37 Integrated Voltage Measurement... 15:33:46 Voltage Offset Correction: v_off_ini = 2301.617 uV, v_off_fin = 2294.127 uV 15:33:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.114 uVs 15:33:46 Integrated Voltage Measurement... 15:33:55 Voltage Offset Correction: v_off_ini = 2302.129 uV, v_off_fin = 2337.593 uV 15:33:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.126 uVs 15:33:57 I2Y Average and RMS of Measurements VT = -270.916 +- 3.104 uVs I2Y = -24.925 +- 0.285 uTm^2 15:34:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:14 Integrated Voltage Measurement... 15:34:23 Voltage Offset Correction: v_off_ini = 2316.180 uV, v_off_fin = 2289.713 uV 15:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -95.549 uVs 15:34:23 Integrated Voltage Measurement... 15:34:32 Voltage Offset Correction: v_off_ini = 2305.540 uV, v_off_fin = 2310.696 uV 15:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.713 uVs 15:34:32 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = 2294.688 uV, v_off_fin = 2296.778 uV 15:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.009 uVs 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = 2279.352 uV, v_off_fin = 2301.552 uV 15:34:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.493 uVs 15:34:50 Integrated Voltage Measurement... 15:34:59 Voltage Offset Correction: v_off_ini = 2302.564 uV, v_off_fin = 2298.156 uV 15:34:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.711 uVs 15:34:59 Integrated Voltage Measurement... 15:35:08 Voltage Offset Correction: v_off_ini = 2293.192 uV, v_off_fin = 2292.963 uV 15:35:08 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.496 uVs 15:35:12 I1X Average and RMS of Measurements VT = -92.829 +- 11.083 uVs I1X = 18.567 +- 2.216 uTm 15:35:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:19 Integrated Voltage Measurement... 15:35:28 Voltage Offset Correction: v_off_ini = 2263.650 uV, v_off_fin = 2279.888 uV 15:35:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -157.049 uVs 15:35:28 Integrated Voltage Measurement... 15:35:37 Voltage Offset Correction: v_off_ini = 2285.978 uV, v_off_fin = 2293.526 uV 15:35:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.211 uVs 15:35:37 Integrated Voltage Measurement... 15:35:46 Voltage Offset Correction: v_off_ini = 2290.194 uV, v_off_fin = 2286.448 uV 15:35:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.147 uVs 15:35:46 Integrated Voltage Measurement... 15:35:55 Voltage Offset Correction: v_off_ini = 2297.206 uV, v_off_fin = 2278.769 uV 15:35:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.799 uVs 15:35:55 Integrated Voltage Measurement... 15:36:04 Voltage Offset Correction: v_off_ini = 2272.642 uV, v_off_fin = 2277.370 uV 15:36:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -137.325 uVs 15:36:04 Integrated Voltage Measurement... 15:36:13 Voltage Offset Correction: v_off_ini = 2277.301 uV, v_off_fin = 2292.501 uV 15:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.359 uVs 15:36:17 I1Y Average and RMS of Measurements VT = -172.815 +- 10.701 uVs I1Y = -34.561 +- 2.141 uTm 15:36:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:24 Integrated Voltage Measurement... 15:36:33 Voltage Offset Correction: v_off_ini = 2299.997 uV, v_off_fin = 2275.802 uV 15:36:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -59.762 uVs 15:36:33 Integrated Voltage Measurement... 15:36:42 Voltage Offset Correction: v_off_ini = 2295.148 uV, v_off_fin = 2308.585 uV 15:36:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.838 uVs 15:36:43 Integrated Voltage Measurement... 15:36:51 Voltage Offset Correction: v_off_ini = 2287.694 uV, v_off_fin = 2292.860 uV 15:36:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.649 uVs 15:36:52 Integrated Voltage Measurement... 15:37:01 Voltage Offset Correction: v_off_ini = 2303.276 uV, v_off_fin = 2308.028 uV 15:37:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.824 uVs 15:37:01 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 2292.475 uV, v_off_fin = 2285.444 uV 15:37:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -94.325 uVs 15:37:10 Integrated Voltage Measurement... 15:37:19 Voltage Offset Correction: v_off_ini = 2305.541 uV, v_off_fin = 2301.264 uV 15:37:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.362 uVs 15:37:21 I2X Average and RMS of Measurements VT = -77.627 +- 8.670 uVs I2X = 7.142 +- 0.798 uTm^2 15:37:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:37:29 Integrated Voltage Measurement... 15:37:38 Voltage Offset Correction: v_off_ini = 2281.500 uV, v_off_fin = 2284.150 uV 15:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.230 uVs 15:37:38 Integrated Voltage Measurement... 15:37:47 Voltage Offset Correction: v_off_ini = 2281.736 uV, v_off_fin = 2284.424 uV 15:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.364 uVs 15:37:47 Integrated Voltage Measurement... 15:37:56 Voltage Offset Correction: v_off_ini = 2271.761 uV, v_off_fin = 2288.350 uV 15:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.446 uVs 15:37:56 Integrated Voltage Measurement... 15:38:05 Voltage Offset Correction: v_off_ini = 2299.914 uV, v_off_fin = 2276.447 uV 15:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.812 uVs 15:38:05 Integrated Voltage Measurement... 15:38:14 Voltage Offset Correction: v_off_ini = 2292.424 uV, v_off_fin = 2286.683 uV 15:38:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.628 uVs 15:38:14 Integrated Voltage Measurement... 15:38:23 Voltage Offset Correction: v_off_ini = 2291.522 uV, v_off_fin = 2313.157 uV 15:38:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.998 uVs 15:38:25 I2Y Average and RMS of Measurements VT = -263.080 +- 9.138 uVs I2Y = -24.203 +- 0.841 uTm^2 15:38:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:44 Integrated Voltage Measurement... 15:38:53 Voltage Offset Correction: v_off_ini = 2315.335 uV, v_off_fin = 2296.193 uV 15:38:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -115.759 uVs 15:38:53 Integrated Voltage Measurement... 15:39:02 Voltage Offset Correction: v_off_ini = 2327.251 uV, v_off_fin = 2327.491 uV 15:39:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.011 uVs 15:39:02 Integrated Voltage Measurement... 15:39:11 Voltage Offset Correction: v_off_ini = 2335.718 uV, v_off_fin = 2323.350 uV 15:39:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.770 uVs 15:39:11 Integrated Voltage Measurement... 15:39:20 Voltage Offset Correction: v_off_ini = 2311.643 uV, v_off_fin = 2310.696 uV 15:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.560 uVs 15:39:20 Integrated Voltage Measurement... 15:39:29 Voltage Offset Correction: v_off_ini = 2307.117 uV, v_off_fin = 2290.200 uV 15:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.037 uVs 15:39:29 Integrated Voltage Measurement... 15:39:38 Voltage Offset Correction: v_off_ini = 2276.556 uV, v_off_fin = 2291.058 uV 15:39:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.969 uVs 15:39:42 I1X Average and RMS of Measurements VT = -96.018 +- 4.899 uVs I1X = 19.206 +- 0.979 uTm 15:39:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:49 Integrated Voltage Measurement... 15:39:58 Voltage Offset Correction: v_off_ini = 2283.765 uV, v_off_fin = 2265.749 uV 15:39:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.068 uVs 15:39:58 Integrated Voltage Measurement... 15:40:07 Voltage Offset Correction: v_off_ini = 2289.112 uV, v_off_fin = 2313.500 uV 15:40:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.782 uVs 15:40:07 Integrated Voltage Measurement... 15:40:16 Voltage Offset Correction: v_off_ini = 2276.185 uV, v_off_fin = 2290.300 uV 15:40:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.127 uVs 15:40:16 Integrated Voltage Measurement... 15:40:25 Voltage Offset Correction: v_off_ini = 2276.287 uV, v_off_fin = 2267.366 uV 15:40:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.094 uVs 15:40:25 Integrated Voltage Measurement... 15:40:34 Voltage Offset Correction: v_off_ini = 2276.074 uV, v_off_fin = 2272.624 uV 15:40:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.656 uVs 15:40:34 Integrated Voltage Measurement... 15:40:42 Voltage Offset Correction: v_off_ini = 2247.916 uV, v_off_fin = 2310.049 uV 15:40:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.369 uVs 15:40:47 I1Y Average and RMS of Measurements VT = -181.516 +- 7.138 uVs I1Y = -36.303 +- 1.427 uTm 15:40:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:54 Integrated Voltage Measurement... 15:41:03 Voltage Offset Correction: v_off_ini = 2261.234 uV, v_off_fin = 2267.642 uV 15:41:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -93.296 uVs 15:41:03 Integrated Voltage Measurement... 15:41:12 Voltage Offset Correction: v_off_ini = 2263.165 uV, v_off_fin = 2309.576 uV 15:41:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.471 uVs 15:41:12 Integrated Voltage Measurement... 15:41:21 Voltage Offset Correction: v_off_ini = 2286.544 uV, v_off_fin = 2268.527 uV 15:41:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.151 uVs 15:41:21 Integrated Voltage Measurement... 15:41:30 Voltage Offset Correction: v_off_ini = 2265.590 uV, v_off_fin = 2264.251 uV 15:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.459 uVs 15:41:31 Integrated Voltage Measurement... 15:41:40 Voltage Offset Correction: v_off_ini = 2255.068 uV, v_off_fin = 2282.912 uV 15:41:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.684 uVs 15:41:40 Integrated Voltage Measurement... 15:41:49 Voltage Offset Correction: v_off_ini = 2300.422 uV, v_off_fin = 2296.372 uV 15:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.759 uVs 15:41:51 I2X Average and RMS of Measurements VT = -86.470 +- 3.365 uVs I2X = 7.955 +- 0.309 uTm^2 15:41:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:59 Integrated Voltage Measurement... 15:42:08 Voltage Offset Correction: v_off_ini = 2314.191 uV, v_off_fin = 2316.689 uV 15:42:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.085 uVs 15:42:08 Integrated Voltage Measurement... 15:42:17 Voltage Offset Correction: v_off_ini = 2340.300 uV, v_off_fin = 2289.678 uV 15:42:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.899 uVs 15:42:17 Integrated Voltage Measurement... 15:42:26 Voltage Offset Correction: v_off_ini = 2328.591 uV, v_off_fin = 2310.166 uV 15:42:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.403 uVs 15:42:26 Integrated Voltage Measurement... 15:42:35 Voltage Offset Correction: v_off_ini = 2322.130 uV, v_off_fin = 2344.224 uV 15:42:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.073 uVs 15:42:35 Integrated Voltage Measurement... 15:42:44 Voltage Offset Correction: v_off_ini = 2326.908 uV, v_off_fin = 2319.071 uV 15:42:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.046 uVs 15:42:44 Integrated Voltage Measurement... 15:42:53 Voltage Offset Correction: v_off_ini = 2320.215 uV, v_off_fin = 2305.743 uV 15:42:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.633 uVs 15:42:55 I2Y Average and RMS of Measurements VT = -243.857 +- 7.687 uVs I2Y = -22.435 +- 0.707 uTm^2 15:43:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:14 Integrated Voltage Measurement... 15:43:23 Voltage Offset Correction: v_off_ini = 2300.798 uV, v_off_fin = 2309.927 uV 15:43:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.572 uVs 15:43:23 Integrated Voltage Measurement... 15:43:32 Voltage Offset Correction: v_off_ini = 2304.400 uV, v_off_fin = 2288.970 uV 15:43:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.932 uVs 15:43:32 Integrated Voltage Measurement... 15:43:41 Voltage Offset Correction: v_off_ini = 2292.924 uV, v_off_fin = 2282.502 uV 15:43:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.495 uVs 15:43:41 Integrated Voltage Measurement... 15:43:50 Voltage Offset Correction: v_off_ini = 2277.474 uV, v_off_fin = 2306.548 uV 15:43:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.853 uVs 15:43:50 Integrated Voltage Measurement... 15:43:59 Voltage Offset Correction: v_off_ini = 2307.934 uV, v_off_fin = 2296.091 uV 15:43:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.227 uVs 15:43:59 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = 2308.709 uV, v_off_fin = 2307.077 uV 15:44:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.857 uVs 15:44:12 I1X Average and RMS of Measurements VT = -89.323 +- 5.114 uVs I1X = 17.865 +- 1.023 uTm 15:44:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:19 Integrated Voltage Measurement... 15:44:28 Voltage Offset Correction: v_off_ini = 2292.128 uV, v_off_fin = 2297.057 uV 15:44:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -197.562 uVs 15:44:28 Integrated Voltage Measurement... 15:44:37 Voltage Offset Correction: v_off_ini = 2291.736 uV, v_off_fin = 2300.852 uV 15:44:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.760 uVs 15:44:37 Integrated Voltage Measurement... 15:44:46 Voltage Offset Correction: v_off_ini = 2295.147 uV, v_off_fin = 2277.280 uV 15:44:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.000 uVs 15:44:46 Integrated Voltage Measurement... 15:44:55 Voltage Offset Correction: v_off_ini = 2291.745 uV, v_off_fin = 2312.551 uV 15:44:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.917 uVs 15:44:55 Integrated Voltage Measurement... 15:45:04 Voltage Offset Correction: v_off_ini = 2287.662 uV, v_off_fin = 2262.076 uV 15:45:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.185 uVs 15:45:04 Integrated Voltage Measurement... 15:45:12 Voltage Offset Correction: v_off_ini = 2288.632 uV, v_off_fin = 2313.962 uV 15:45:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 166.356 uVs 15:45:17 I1Y Average and RMS of Measurements VT = -184.964 +- 11.264 uVs I1Y = -36.991 +- 2.255 uTm 15:45:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:24 Integrated Voltage Measurement... 15:45:33 Voltage Offset Correction: v_off_ini = 2324.248 uV, v_off_fin = 2316.537 uV 15:45:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.774 uVs 15:45:33 Integrated Voltage Measurement... 15:45:42 Voltage Offset Correction: v_off_ini = 2314.959 uV, v_off_fin = 2324.076 uV 15:45:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.207 uVs 15:45:42 Integrated Voltage Measurement... 15:45:51 Voltage Offset Correction: v_off_ini = 2328.494 uV, v_off_fin = 2330.399 uV 15:45:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.362 uVs 15:45:52 Integrated Voltage Measurement... 15:46:01 Voltage Offset Correction: v_off_ini = 2329.460 uV, v_off_fin = 2356.654 uV 15:46:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.321 uVs 15:46:01 Integrated Voltage Measurement... 15:46:10 Voltage Offset Correction: v_off_ini = 2360.387 uV, v_off_fin = 2340.521 uV 15:46:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.649 uVs 15:46:10 Integrated Voltage Measurement... 15:46:19 Voltage Offset Correction: v_off_ini = 2351.518 uV, v_off_fin = 2361.348 uV 15:46:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.314 uVs 15:46:21 I2X Average and RMS of Measurements VT = -90.938 +- 4.747 uVs I2X = 8.366 +- 0.437 uTm^2 15:46:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:29 Integrated Voltage Measurement... 15:46:38 Voltage Offset Correction: v_off_ini = 2365.478 uV, v_off_fin = 2347.487 uV 15:46:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.667 uVs 15:46:38 Integrated Voltage Measurement... 15:46:47 Voltage Offset Correction: v_off_ini = 2347.266 uV, v_off_fin = 2354.378 uV 15:46:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.682 uVs 15:46:47 Integrated Voltage Measurement... 15:46:56 Voltage Offset Correction: v_off_ini = 2367.122 uV, v_off_fin = 2377.709 uV 15:46:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.662 uVs 15:46:56 Integrated Voltage Measurement... 15:47:05 Voltage Offset Correction: v_off_ini = 2363.997 uV, v_off_fin = 2363.899 uV 15:47:05 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 275.545 uVs 15:47:05 Integrated Voltage Measurement... 15:47:14 Voltage Offset Correction: v_off_ini = 2353.020 uV, v_off_fin = 2351.431 uV 15:47:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.721 uVs 15:47:14 Integrated Voltage Measurement... 15:47:23 Voltage Offset Correction: v_off_ini = 2341.336 uV, v_off_fin = 2343.009 uV 15:47:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.910 uVs 15:47:25 I2Y Average and RMS of Measurements VT = -263.198 +- 5.346 uVs I2Y = -24.215 +- 0.492 uTm^2 15:47:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:47:44 Integrated Voltage Measurement... 15:47:53 Voltage Offset Correction: v_off_ini = 2350.592 uV, v_off_fin = 2325.022 uV 15:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.761 uVs 15:47:53 Integrated Voltage Measurement... 15:48:02 Voltage Offset Correction: v_off_ini = 2345.319 uV, v_off_fin = 2348.679 uV 15:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.302 uVs 15:48:02 Integrated Voltage Measurement... 15:48:11 Voltage Offset Correction: v_off_ini = 2333.420 uV, v_off_fin = 2321.415 uV 15:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.115 uVs 15:48:11 Integrated Voltage Measurement... 15:48:20 Voltage Offset Correction: v_off_ini = 2361.192 uV, v_off_fin = 2363.665 uV 15:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.148 uVs 15:48:20 Integrated Voltage Measurement... 15:48:29 Voltage Offset Correction: v_off_ini = 2361.214 uV, v_off_fin = 2366.399 uV 15:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.553 uVs 15:48:29 Integrated Voltage Measurement... 15:48:38 Voltage Offset Correction: v_off_ini = 2368.466 uV, v_off_fin = 2367.671 uV 15:48:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.185 uVs 15:48:42 I1X Average and RMS of Measurements VT = -86.344 +- 7.081 uVs I1X = 17.269 +- 1.417 uTm 15:48:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:49 Integrated Voltage Measurement... 15:48:58 Voltage Offset Correction: v_off_ini = 2349.553 uV, v_off_fin = 2339.362 uV 15:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.923 uVs 15:48:58 Integrated Voltage Measurement... 15:49:07 Voltage Offset Correction: v_off_ini = 2354.873 uV, v_off_fin = 2365.428 uV 15:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 193.248 uVs 15:49:07 Integrated Voltage Measurement... 15:49:16 Voltage Offset Correction: v_off_ini = 2343.578 uV, v_off_fin = 2341.704 uV 15:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.112 uVs 15:49:16 Integrated Voltage Measurement... 15:49:25 Voltage Offset Correction: v_off_ini = 2348.255 uV, v_off_fin = 2341.193 uV 15:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.052 uVs 15:49:25 Integrated Voltage Measurement... 15:49:34 Voltage Offset Correction: v_off_ini = 2366.201 uV, v_off_fin = 2361.292 uV 15:49:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.674 uVs 15:49:34 Integrated Voltage Measurement... 15:49:43 Voltage Offset Correction: v_off_ini = 2380.790 uV, v_off_fin = 2382.480 uV 15:49:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.439 uVs 15:49:47 I1Y Average and RMS of Measurements VT = -201.908 +- 17.425 uVs I1Y = -40.380 +- 3.486 uTm 15:49:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:54 Integrated Voltage Measurement... 15:50:03 Voltage Offset Correction: v_off_ini = 2370.154 uV, v_off_fin = 2351.236 uV 15:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.833 uVs 15:50:04 Integrated Voltage Measurement... 15:50:12 Voltage Offset Correction: v_off_ini = 2363.242 uV, v_off_fin = 2353.818 uV 15:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.738 uVs 15:50:13 Integrated Voltage Measurement... 15:50:22 Voltage Offset Correction: v_off_ini = 2360.542 uV, v_off_fin = 2358.829 uV 15:50:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.988 uVs 15:50:22 Integrated Voltage Measurement... 15:50:31 Voltage Offset Correction: v_off_ini = 2359.394 uV, v_off_fin = 2363.920 uV 15:50:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.220 uVs 15:50:31 Integrated Voltage Measurement... 15:50:40 Voltage Offset Correction: v_off_ini = 2356.376 uV, v_off_fin = 2334.779 uV 15:50:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.701 uVs 15:50:40 Integrated Voltage Measurement... 15:50:49 Voltage Offset Correction: v_off_ini = 2357.500 uV, v_off_fin = 2363.702 uV 15:50:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.443 uVs 15:50:51 I2X Average and RMS of Measurements VT = -92.654 +- 1.397 uVs I2X = 8.524 +- 0.129 uTm^2 15:50:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = 2371.294 uV, v_off_fin = 2356.675 uV 15:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.267 uVs 15:51:08 Integrated Voltage Measurement... 15:51:17 Voltage Offset Correction: v_off_ini = 2356.151 uV, v_off_fin = 2364.862 uV 15:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.493 uVs 15:51:17 Integrated Voltage Measurement... 15:51:26 Voltage Offset Correction: v_off_ini = 2344.016 uV, v_off_fin = 2354.838 uV 15:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.527 uVs 15:51:26 Integrated Voltage Measurement... 15:51:35 Voltage Offset Correction: v_off_ini = 2355.739 uV, v_off_fin = 2349.629 uV 15:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.728 uVs 15:51:35 Integrated Voltage Measurement... 15:51:44 Voltage Offset Correction: v_off_ini = 2362.433 uV, v_off_fin = 2345.077 uV 15:51:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.009 uVs 15:51:44 Integrated Voltage Measurement... 15:51:53 Voltage Offset Correction: v_off_ini = 2353.082 uV, v_off_fin = 2357.580 uV 15:51:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.842 uVs 15:51:55 I2Y Average and RMS of Measurements VT = -256.478 +- 16.889 uVs I2Y = -23.596 +- 1.554 uTm^2 15:52:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:14 Integrated Voltage Measurement... 15:52:23 Voltage Offset Correction: v_off_ini = 2383.756 uV, v_off_fin = 2354.228 uV 15:52:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.074 uVs 15:52:23 Integrated Voltage Measurement... 15:52:32 Voltage Offset Correction: v_off_ini = 2371.971 uV, v_off_fin = 2387.590 uV 15:52:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 12.878 uVs 15:52:32 Integrated Voltage Measurement... 15:52:41 Voltage Offset Correction: v_off_ini = 2374.115 uV, v_off_fin = 2393.243 uV 15:52:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.748 uVs 15:52:41 Integrated Voltage Measurement... 15:52:50 Voltage Offset Correction: v_off_ini = 2390.762 uV, v_off_fin = 2386.887 uV 15:52:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.639 uVs 15:52:50 Integrated Voltage Measurement... 15:52:59 Voltage Offset Correction: v_off_ini = 2366.919 uV, v_off_fin = 2386.439 uV 15:52:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.660 uVs 15:52:59 Integrated Voltage Measurement... 15:53:08 Voltage Offset Correction: v_off_ini = 2379.468 uV, v_off_fin = 2383.993 uV 15:53:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.369 uVs 15:53:12 I1X Average and RMS of Measurements VT = -67.561 +- 11.852 uVs I1X = 13.512 +- 2.370 uTm 15:53:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:19 Integrated Voltage Measurement... 15:53:28 Voltage Offset Correction: v_off_ini = 2353.527 uV, v_off_fin = 2363.766 uV 15:53:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.349 uVs 15:53:28 Integrated Voltage Measurement... 15:53:37 Voltage Offset Correction: v_off_ini = 2376.699 uV, v_off_fin = 2400.756 uV 15:53:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 227.504 uVs 15:53:37 Integrated Voltage Measurement... 15:53:46 Voltage Offset Correction: v_off_ini = 2383.046 uV, v_off_fin = 2378.021 uV 15:53:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.187 uVs 15:53:46 Integrated Voltage Measurement... 15:53:55 Voltage Offset Correction: v_off_ini = 2375.030 uV, v_off_fin = 2384.039 uV 15:53:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.017 uVs 15:53:55 Integrated Voltage Measurement... 15:54:04 Voltage Offset Correction: v_off_ini = 2416.897 uV, v_off_fin = 2420.818 uV 15:54:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.573 uVs 15:54:04 Integrated Voltage Measurement... 15:54:13 Voltage Offset Correction: v_off_ini = 2413.448 uV, v_off_fin = 2421.914 uV 15:54:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.211 uVs 15:54:17 I1Y Average and RMS of Measurements VT = -207.807 +- 4.682 uVs I1Y = -41.557 +- 0.936 uTm 15:54:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:25 Integrated Voltage Measurement... 15:54:33 Voltage Offset Correction: v_off_ini = 2388.156 uV, v_off_fin = 2408.579 uV 15:54:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -84.829 uVs 15:54:34 Integrated Voltage Measurement... 15:54:43 Voltage Offset Correction: v_off_ini = 2414.626 uV, v_off_fin = 2421.545 uV 15:54:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.969 uVs 15:54:43 Integrated Voltage Measurement... 15:54:52 Voltage Offset Correction: v_off_ini = 2415.594 uV, v_off_fin = 2399.285 uV 15:54:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.605 uVs 15:54:52 Integrated Voltage Measurement... 15:55:01 Voltage Offset Correction: v_off_ini = 2407.227 uV, v_off_fin = 2401.825 uV 15:55:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.215 uVs 15:55:01 Integrated Voltage Measurement... 15:55:10 Voltage Offset Correction: v_off_ini = 2390.463 uV, v_off_fin = 2393.691 uV 15:55:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.597 uVs 15:55:10 Integrated Voltage Measurement... 15:55:19 Voltage Offset Correction: v_off_ini = 2410.801 uV, v_off_fin = 2428.924 uV 15:55:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.888 uVs 15:55:21 I2X Average and RMS of Measurements VT = -80.684 +- 8.700 uVs I2X = 7.423 +- 0.801 uTm^2 15:55:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:29 Integrated Voltage Measurement... 15:55:38 Voltage Offset Correction: v_off_ini = 2380.296 uV, v_off_fin = 2416.498 uV 15:55:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.726 uVs 15:55:38 Integrated Voltage Measurement... 15:55:47 Voltage Offset Correction: v_off_ini = 2411.635 uV, v_off_fin = 2398.843 uV 15:55:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.787 uVs 15:55:47 Integrated Voltage Measurement... 15:55:56 Voltage Offset Correction: v_off_ini = 2404.845 uV, v_off_fin = 2402.674 uV 15:55:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.505 uVs 15:55:56 Integrated Voltage Measurement... 15:56:05 Voltage Offset Correction: v_off_ini = 2408.890 uV, v_off_fin = 2406.921 uV 15:56:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.366 uVs 15:56:05 Integrated Voltage Measurement... 15:56:14 Voltage Offset Correction: v_off_ini = 2407.968 uV, v_off_fin = 2418.279 uV 15:56:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.809 uVs 15:56:14 Integrated Voltage Measurement... 15:56:23 Voltage Offset Correction: v_off_ini = 2388.144 uV, v_off_fin = 2393.326 uV 15:56:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.923 uVs 15:56:25 I2Y Average and RMS of Measurements VT = -248.519 +- 5.810 uVs I2Y = -22.864 +- 0.535 uTm^2 15:56:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:44 Integrated Voltage Measurement... 15:56:53 Voltage Offset Correction: v_off_ini = 2425.845 uV, v_off_fin = 2407.234 uV 15:56:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -90.214 uVs 15:56:53 Integrated Voltage Measurement... 15:57:02 Voltage Offset Correction: v_off_ini = 2418.497 uV, v_off_fin = 2439.590 uV 15:57:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.269 uVs 15:57:02 Integrated Voltage Measurement... 15:57:11 Voltage Offset Correction: v_off_ini = 2414.555 uV, v_off_fin = 2412.882 uV 15:57:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.644 uVs 15:57:11 Integrated Voltage Measurement... 15:57:20 Voltage Offset Correction: v_off_ini = 2422.341 uV, v_off_fin = 2436.276 uV 15:57:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.641 uVs 15:57:20 Integrated Voltage Measurement... 15:57:29 Voltage Offset Correction: v_off_ini = 2415.570 uV, v_off_fin = 2425.813 uV 15:57:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.560 uVs 15:57:29 Integrated Voltage Measurement... 15:57:38 Voltage Offset Correction: v_off_ini = 2428.699 uV, v_off_fin = 2412.839 uV 15:57:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.194 uVs 15:57:42 I1X Average and RMS of Measurements VT = -77.420 +- 8.718 uVs I1X = 15.485 +- 1.745 uTm 15:57:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:49 Integrated Voltage Measurement... 15:57:58 Voltage Offset Correction: v_off_ini = 2383.887 uV, v_off_fin = 2372.792 uV 15:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.373 uVs 15:57:58 Integrated Voltage Measurement... 15:58:07 Voltage Offset Correction: v_off_ini = 2413.291 uV, v_off_fin = 2428.919 uV 15:58:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.088 uVs 15:58:07 Integrated Voltage Measurement... 15:58:16 Voltage Offset Correction: v_off_ini = 2389.079 uV, v_off_fin = 2377.885 uV 15:58:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.660 uVs 15:58:16 Integrated Voltage Measurement... 15:58:25 Voltage Offset Correction: v_off_ini = 2399.256 uV, v_off_fin = 2413.015 uV 15:58:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 215.838 uVs 15:58:25 Integrated Voltage Measurement... 15:58:34 Voltage Offset Correction: v_off_ini = 2407.276 uV, v_off_fin = 2381.689 uV 15:58:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.345 uVs 15:58:34 Integrated Voltage Measurement... 15:58:43 Voltage Offset Correction: v_off_ini = 2412.833 uV, v_off_fin = 2423.190 uV 15:58:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.516 uVs 15:58:47 I1Y Average and RMS of Measurements VT = -202.803 +- 11.629 uVs I1Y = -40.559 +- 2.325 uTm 15:58:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:55 Integrated Voltage Measurement... 15:59:04 Voltage Offset Correction: v_off_ini = 2382.298 uV, v_off_fin = 2364.278 uV 15:59:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.688 uVs 15:59:04 Integrated Voltage Measurement... 15:59:13 Voltage Offset Correction: v_off_ini = 2404.556 uV, v_off_fin = 2398.044 uV 15:59:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.789 uVs 15:59:13 Integrated Voltage Measurement... 15:59:22 Voltage Offset Correction: v_off_ini = 2389.998 uV, v_off_fin = 2388.154 uV 15:59:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.652 uVs 15:59:22 Integrated Voltage Measurement... 15:59:31 Voltage Offset Correction: v_off_ini = 2404.757 uV, v_off_fin = 2414.749 uV 15:59:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.346 uVs 15:59:31 Integrated Voltage Measurement... 15:59:40 Voltage Offset Correction: v_off_ini = 2426.624 uV, v_off_fin = 2396.463 uV 15:59:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.673 uVs 15:59:40 Integrated Voltage Measurement... 15:59:49 Voltage Offset Correction: v_off_ini = 2406.333 uV, v_off_fin = 2421.868 uV 15:59:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.787 uVs 15:59:51 I2X Average and RMS of Measurements VT = -68.823 +- 4.541 uVs I2X = 6.332 +- 0.418 uTm^2 15:59:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:59 Integrated Voltage Measurement... 16:00:08 Voltage Offset Correction: v_off_ini = 2409.210 uV, v_off_fin = 2407.787 uV 16:00:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.143 uVs 16:00:08 Integrated Voltage Measurement... 16:00:17 Voltage Offset Correction: v_off_ini = 2401.304 uV, v_off_fin = 2412.304 uV 16:00:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.296 uVs 16:00:17 Integrated Voltage Measurement... 16:00:26 Voltage Offset Correction: v_off_ini = 2418.772 uV, v_off_fin = 2423.548 uV 16:00:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.173 uVs 16:00:26 Integrated Voltage Measurement... 16:00:35 Voltage Offset Correction: v_off_ini = 2439.982 uV, v_off_fin = 2442.840 uV 16:00:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.533 uVs 16:00:35 Integrated Voltage Measurement... 16:00:44 Voltage Offset Correction: v_off_ini = 2431.912 uV, v_off_fin = 2449.005 uV 16:00:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.277 uVs 16:00:44 Integrated Voltage Measurement... 16:00:53 Voltage Offset Correction: v_off_ini = 2435.580 uV, v_off_fin = 2415.673 uV 16:00:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.277 uVs 16:00:55 I2Y Average and RMS of Measurements VT = -271.283 +- 7.666 uVs I2Y = -24.958 +- 0.705 uTm^2 16:01:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:14 Integrated Voltage Measurement... 16:01:23 Voltage Offset Correction: v_off_ini = 2444.941 uV, v_off_fin = 2451.884 uV 16:01:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.061 uVs 16:01:23 Integrated Voltage Measurement... 16:01:32 Voltage Offset Correction: v_off_ini = 2464.431 uV, v_off_fin = 2450.913 uV 16:01:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.033 uVs 16:01:32 Integrated Voltage Measurement... 16:01:41 Voltage Offset Correction: v_off_ini = 2479.429 uV, v_off_fin = 2462.821 uV 16:01:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.488 uVs 16:01:41 Integrated Voltage Measurement... 16:01:50 Voltage Offset Correction: v_off_ini = 2470.455 uV, v_off_fin = 2467.320 uV 16:01:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.591 uVs 16:01:50 Integrated Voltage Measurement... 16:01:59 Voltage Offset Correction: v_off_ini = 2445.088 uV, v_off_fin = 2437.177 uV 16:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.182 uVs 16:01:59 Integrated Voltage Measurement... 16:02:08 Voltage Offset Correction: v_off_ini = 2439.631 uV, v_off_fin = 2426.873 uV 16:02:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.803 uVs 16:02:12 I1X Average and RMS of Measurements VT = -82.860 +- 5.717 uVs I1X = 16.572 +- 1.144 uTm 16:02:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:19 Integrated Voltage Measurement... 16:02:28 Voltage Offset Correction: v_off_ini = 2450.005 uV, v_off_fin = 2436.827 uV 16:02:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.356 uVs 16:02:28 Integrated Voltage Measurement... 16:02:37 Voltage Offset Correction: v_off_ini = 2436.269 uV, v_off_fin = 2451.369 uV 16:02:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 211.860 uVs 16:02:37 Integrated Voltage Measurement... 16:02:46 Voltage Offset Correction: v_off_ini = 2441.840 uV, v_off_fin = 2437.513 uV 16:02:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.705 uVs 16:02:46 Integrated Voltage Measurement... 16:02:55 Voltage Offset Correction: v_off_ini = 2453.952 uV, v_off_fin = 2460.020 uV 16:02:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.291 uVs 16:02:55 Integrated Voltage Measurement... 16:03:04 Voltage Offset Correction: v_off_ini = 2453.282 uV, v_off_fin = 2441.307 uV 16:03:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.440 uVs 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = 2455.399 uV, v_off_fin = 2441.535 uV 16:03:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.313 uVs 16:03:17 I1Y Average and RMS of Measurements VT = -219.328 +- 11.713 uVs I1Y = -43.863 +- 2.344 uTm 16:03:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:25 Integrated Voltage Measurement... 16:03:34 Voltage Offset Correction: v_off_ini = 2443.497 uV, v_off_fin = 2422.778 uV 16:03:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.863 uVs 16:03:34 Integrated Voltage Measurement... 16:03:43 Voltage Offset Correction: v_off_ini = 2437.959 uV, v_off_fin = 2432.330 uV 16:03:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.895 uVs 16:03:43 Integrated Voltage Measurement... 16:03:52 Voltage Offset Correction: v_off_ini = 2422.273 uV, v_off_fin = 2411.850 uV 16:03:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.656 uVs 16:03:52 Integrated Voltage Measurement... 16:04:01 Voltage Offset Correction: v_off_ini = 2438.365 uV, v_off_fin = 2429.515 uV 16:04:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.186 uVs 16:04:01 Integrated Voltage Measurement... 16:04:10 Voltage Offset Correction: v_off_ini = 2389.457 uV, v_off_fin = 2403.646 uV 16:04:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.553 uVs 16:04:10 Integrated Voltage Measurement... 16:04:19 Voltage Offset Correction: v_off_ini = 2395.943 uV, v_off_fin = 2427.338 uV 16:04:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.983 uVs 16:04:21 I2X Average and RMS of Measurements VT = -73.856 +- 6.859 uVs I2X = 6.795 +- 0.631 uTm^2 16:04:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:29 Integrated Voltage Measurement... 16:04:38 Voltage Offset Correction: v_off_ini = 2407.188 uV, v_off_fin = 2408.193 uV 16:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.684 uVs 16:04:38 Integrated Voltage Measurement... 16:04:47 Voltage Offset Correction: v_off_ini = 2404.488 uV, v_off_fin = 2397.317 uV 16:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.514 uVs 16:04:47 Integrated Voltage Measurement... 16:04:56 Voltage Offset Correction: v_off_ini = 2428.426 uV, v_off_fin = 2394.020 uV 16:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.767 uVs 16:04:56 Integrated Voltage Measurement... 16:05:05 Voltage Offset Correction: v_off_ini = 2407.965 uV, v_off_fin = 2389.335 uV 16:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.075 uVs 16:05:05 Integrated Voltage Measurement... 16:05:14 Voltage Offset Correction: v_off_ini = 2386.162 uV, v_off_fin = 2396.373 uV 16:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.554 uVs 16:05:14 Integrated Voltage Measurement... 16:05:23 Voltage Offset Correction: v_off_ini = 2406.796 uV, v_off_fin = 2407.628 uV 16:05:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.596 uVs 16:05:25 I2Y Average and RMS of Measurements VT = -263.032 +- 5.380 uVs I2Y = -24.199 +- 0.495 uTm^2 16:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:37 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm