SLAC Magnetic Measurements Date: 07-24-2026 Time: 09:40:57 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16336 Dataset Number: 1 Run Purpose: Final Results Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 09:41:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:41:58 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:42:00 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:42:01 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:42:03 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:43:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:43:18 Integrated Voltage Measurement... 09:43:27 Voltage Offset Correction: v_off_ini = 2604.605 uV, v_off_fin = 2603.453 uV 09:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.656 uVs 09:43:27 Integrated Voltage Measurement... 09:43:36 Voltage Offset Correction: v_off_ini = 2599.660 uV, v_off_fin = 2606.319 uV 09:43:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.928 uVs 09:43:36 Integrated Voltage Measurement... 09:43:45 Voltage Offset Correction: v_off_ini = 2602.290 uV, v_off_fin = 2612.718 uV 09:43:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.406 uVs 09:43:45 Integrated Voltage Measurement... 09:43:54 Voltage Offset Correction: v_off_ini = 2613.617 uV, v_off_fin = 2608.854 uV 09:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.779 uVs 09:43:54 Integrated Voltage Measurement... 09:44:03 Voltage Offset Correction: v_off_ini = 2615.351 uV, v_off_fin = 2600.386 uV 09:44:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.914 uVs 09:44:03 Integrated Voltage Measurement... 09:44:12 Voltage Offset Correction: v_off_ini = 2632.051 uV, v_off_fin = 2619.040 uV 09:44:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.965 uVs 09:44:16 I1X Average and RMS of Measurements VT = -71.108 +- 7.448 uVs I1X = 14.222 +- 1.489 uTm 09:44:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:44:23 Integrated Voltage Measurement... 09:44:32 Voltage Offset Correction: v_off_ini = 2622.312 uV, v_off_fin = 2631.931 uV 09:44:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.301 uVs 09:44:32 Integrated Voltage Measurement... 09:44:41 Voltage Offset Correction: v_off_ini = 2638.638 uV, v_off_fin = 2632.536 uV 09:44:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.439 uVs 09:44:41 Integrated Voltage Measurement... 09:44:50 Voltage Offset Correction: v_off_ini = 2612.289 uV, v_off_fin = 2615.960 uV 09:44:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.903 uVs 09:44:50 Integrated Voltage Measurement... 09:44:59 Voltage Offset Correction: v_off_ini = 2650.617 uV, v_off_fin = 2658.790 uV 09:44:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.085 uVs 09:44:59 Integrated Voltage Measurement... 09:45:08 Voltage Offset Correction: v_off_ini = 2632.065 uV, v_off_fin = 2607.110 uV 09:45:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.467 uVs 09:45:08 Integrated Voltage Measurement... 09:45:16 Voltage Offset Correction: v_off_ini = 2656.475 uV, v_off_fin = 2656.279 uV 09:45:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.244 uVs 09:45:21 I1Y Average and RMS of Measurements VT = -254.406 +- 8.522 uVs I1Y = -50.881 +- 1.704 uTm 09:45:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:45:28 Integrated Voltage Measurement... 09:45:37 Voltage Offset Correction: v_off_ini = 2634.236 uV, v_off_fin = 2666.077 uV 09:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.804 uVs 09:45:37 Integrated Voltage Measurement... 09:45:46 Voltage Offset Correction: v_off_ini = 2672.407 uV, v_off_fin = 2687.226 uV 09:45:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.101 uVs 09:45:46 Integrated Voltage Measurement... 09:45:55 Voltage Offset Correction: v_off_ini = 2661.313 uV, v_off_fin = 2668.795 uV 09:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.766 uVs 09:45:55 Integrated Voltage Measurement... 09:46:04 Voltage Offset Correction: v_off_ini = 2664.710 uV, v_off_fin = 2675.196 uV 09:46:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.782 uVs 09:46:05 Integrated Voltage Measurement... 09:46:13 Voltage Offset Correction: v_off_ini = 2671.420 uV, v_off_fin = 2682.654 uV 09:46:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.149 uVs 09:46:14 Integrated Voltage Measurement... 09:46:23 Voltage Offset Correction: v_off_ini = 2671.264 uV, v_off_fin = 2687.786 uV 09:46:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.555 uVs 09:46:25 I2X Average and RMS of Measurements VT = -60.526 +- 7.080 uVs I2X = 5.569 +- 0.651 uTm^2 09:46:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:46:33 Integrated Voltage Measurement... 09:46:42 Voltage Offset Correction: v_off_ini = 2655.191 uV, v_off_fin = 2667.611 uV 09:46:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.818 uVs 09:46:42 Integrated Voltage Measurement... 09:46:51 Voltage Offset Correction: v_off_ini = 2666.564 uV, v_off_fin = 2693.497 uV 09:46:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 426.111 uVs 09:46:51 Integrated Voltage Measurement... 09:47:00 Voltage Offset Correction: v_off_ini = 2682.453 uV, v_off_fin = 2681.322 uV 09:47:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -414.203 uVs 09:47:00 Integrated Voltage Measurement... 09:47:09 Voltage Offset Correction: v_off_ini = 2696.130 uV, v_off_fin = 2691.908 uV 09:47:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 405.969 uVs 09:47:09 Integrated Voltage Measurement... 09:47:18 Voltage Offset Correction: v_off_ini = 2710.164 uV, v_off_fin = 2692.341 uV 09:47:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -427.083 uVs 09:47:18 Integrated Voltage Measurement... 09:47:27 Voltage Offset Correction: v_off_ini = 2697.929 uV, v_off_fin = 2693.022 uV 09:47:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 405.703 uVs 09:47:29 I2Y Average and RMS of Measurements VT = -412.981 +- 2.601 uVs I2Y = -37.994 +- 0.239 uTm^2 09:47:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:47:44 Integrated Voltage Measurement... 09:47:53 Voltage Offset Correction: v_off_ini = 2679.970 uV, v_off_fin = 2683.414 uV 09:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.535 uVs 09:47:53 Integrated Voltage Measurement... 09:48:02 Voltage Offset Correction: v_off_ini = 2677.067 uV, v_off_fin = 2673.778 uV 09:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.614 uVs 09:48:02 Integrated Voltage Measurement... 09:48:11 Voltage Offset Correction: v_off_ini = 2699.434 uV, v_off_fin = 2694.894 uV 09:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.252 uVs 09:48:11 Integrated Voltage Measurement... 09:48:20 Voltage Offset Correction: v_off_ini = 2673.863 uV, v_off_fin = 2666.524 uV 09:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.600 uVs 09:48:20 Integrated Voltage Measurement... 09:48:29 Voltage Offset Correction: v_off_ini = 2675.638 uV, v_off_fin = 2681.415 uV 09:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.225 uVs 09:48:29 Integrated Voltage Measurement... 09:48:38 Voltage Offset Correction: v_off_ini = 2690.253 uV, v_off_fin = 2679.178 uV 09:48:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.952 uVs 09:48:42 I1X Average and RMS of Measurements VT = -55.863 +- 1.580 uVs I1X = 11.173 +- 0.316 uTm 09:48:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:48:49 Integrated Voltage Measurement... 09:48:58 Voltage Offset Correction: v_off_ini = 2673.264 uV, v_off_fin = 2664.371 uV 09:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.001 uVs 09:48:58 Integrated Voltage Measurement... 09:49:07 Voltage Offset Correction: v_off_ini = 2665.244 uV, v_off_fin = 2701.794 uV 09:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.840 uVs 09:49:07 Integrated Voltage Measurement... 09:49:16 Voltage Offset Correction: v_off_ini = 2691.081 uV, v_off_fin = 2660.889 uV 09:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.740 uVs 09:49:16 Integrated Voltage Measurement... 09:49:25 Voltage Offset Correction: v_off_ini = 2660.709 uV, v_off_fin = 2659.190 uV 09:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.707 uVs 09:49:25 Integrated Voltage Measurement... 09:49:34 Voltage Offset Correction: v_off_ini = 2703.472 uV, v_off_fin = 2697.131 uV 09:49:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.141 uVs 09:49:34 Integrated Voltage Measurement... 09:49:43 Voltage Offset Correction: v_off_ini = 2688.263 uV, v_off_fin = 2699.693 uV 09:49:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.398 uVs 09:49:47 I1Y Average and RMS of Measurements VT = -243.638 +- 5.887 uVs I1Y = -48.728 +- 1.177 uTm 09:49:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:49:55 Integrated Voltage Measurement... 09:50:04 Voltage Offset Correction: v_off_ini = 2673.787 uV, v_off_fin = 2672.367 uV 09:50:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.549 uVs 09:50:04 Integrated Voltage Measurement... 09:50:13 Voltage Offset Correction: v_off_ini = 2681.427 uV, v_off_fin = 2688.179 uV 09:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.644 uVs 09:50:13 Integrated Voltage Measurement... 09:50:22 Voltage Offset Correction: v_off_ini = 2652.293 uV, v_off_fin = 2683.201 uV 09:50:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.041 uVs 09:50:22 Integrated Voltage Measurement... 09:50:31 Voltage Offset Correction: v_off_ini = 2692.795 uV, v_off_fin = 2706.985 uV 09:50:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.858 uVs 09:50:31 Integrated Voltage Measurement... 09:50:40 Voltage Offset Correction: v_off_ini = 2705.802 uV, v_off_fin = 2687.831 uV 09:50:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.075 uVs 09:50:40 Integrated Voltage Measurement... 09:50:49 Voltage Offset Correction: v_off_ini = 2688.456 uV, v_off_fin = 2695.922 uV 09:50:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.661 uVs 09:50:51 I2X Average and RMS of Measurements VT = -70.138 +- 8.793 uVs I2X = 6.453 +- 0.809 uTm^2 09:50:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:50:59 Integrated Voltage Measurement... 09:51:08 Voltage Offset Correction: v_off_ini = 2685.909 uV, v_off_fin = 2694.971 uV 09:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.672 uVs 09:51:08 Integrated Voltage Measurement... 09:51:17 Voltage Offset Correction: v_off_ini = 2662.103 uV, v_off_fin = 2680.293 uV 09:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 414.183 uVs 09:51:17 Integrated Voltage Measurement... 09:51:26 Voltage Offset Correction: v_off_ini = 2653.877 uV, v_off_fin = 2681.138 uV 09:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.730 uVs 09:51:26 Integrated Voltage Measurement... 09:51:35 Voltage Offset Correction: v_off_ini = 2679.142 uV, v_off_fin = 2672.756 uV 09:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 375.112 uVs 09:51:35 Integrated Voltage Measurement... 09:51:44 Voltage Offset Correction: v_off_ini = 2663.225 uV, v_off_fin = 2670.033 uV 09:51:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -386.509 uVs 09:51:44 Integrated Voltage Measurement... 09:51:53 Voltage Offset Correction: v_off_ini = 2675.595 uV, v_off_fin = 2672.752 uV 09:51:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.995 uVs 09:51:56 I2Y Average and RMS of Measurements VT = -387.033 +- 27.511 uVs I2Y = -35.607 +- 2.531 uTm^2 09:52:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:52:11 Integrated Voltage Measurement... 09:52:19 Voltage Offset Correction: v_off_ini = 2683.994 uV, v_off_fin = 2683.816 uV 09:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.279 uVs 09:52:20 Integrated Voltage Measurement... 09:52:28 Voltage Offset Correction: v_off_ini = 2670.339 uV, v_off_fin = 2699.467 uV 09:52:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.720 uVs 09:52:29 Integrated Voltage Measurement... 09:52:38 Voltage Offset Correction: v_off_ini = 2700.351 uV, v_off_fin = 2694.794 uV 09:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.531 uVs 09:52:38 Integrated Voltage Measurement... 09:52:47 Voltage Offset Correction: v_off_ini = 2692.054 uV, v_off_fin = 2693.547 uV 09:52:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.584 uVs 09:52:47 Integrated Voltage Measurement... 09:52:56 Voltage Offset Correction: v_off_ini = 2706.465 uV, v_off_fin = 2700.666 uV 09:52:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.970 uVs 09:52:56 Integrated Voltage Measurement... 09:53:05 Voltage Offset Correction: v_off_ini = 2676.269 uV, v_off_fin = 2702.080 uV 09:53:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.609 uVs 09:53:09 I1X Average and RMS of Measurements VT = -59.615 +- 19.215 uVs I1X = 11.924 +- 3.843 uTm 09:53:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:53:16 Integrated Voltage Measurement... 09:53:24 Voltage Offset Correction: v_off_ini = 2693.860 uV, v_off_fin = 2700.424 uV 09:53:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.444 uVs 09:53:25 Integrated Voltage Measurement... 09:53:33 Voltage Offset Correction: v_off_ini = 2680.979 uV, v_off_fin = 2686.575 uV 09:53:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.354 uVs 09:53:34 Integrated Voltage Measurement... 09:53:42 Voltage Offset Correction: v_off_ini = 2669.924 uV, v_off_fin = 2677.992 uV 09:53:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.643 uVs 09:53:42 Integrated Voltage Measurement... 09:53:51 Voltage Offset Correction: v_off_ini = 2651.046 uV, v_off_fin = 2685.914 uV 09:53:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.664 uVs 09:53:51 Integrated Voltage Measurement... 09:54:00 Voltage Offset Correction: v_off_ini = 2690.149 uV, v_off_fin = 2685.718 uV 09:54:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.610 uVs 09:54:00 Integrated Voltage Measurement... 09:54:09 Voltage Offset Correction: v_off_ini = 2682.177 uV, v_off_fin = 2703.886 uV 09:54:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.303 uVs 09:54:14 I1Y Average and RMS of Measurements VT = -234.503 +- 9.572 uVs I1Y = -46.901 +- 1.914 uTm 09:54:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:54:21 Integrated Voltage Measurement... 09:54:30 Voltage Offset Correction: v_off_ini = 2706.996 uV, v_off_fin = 2704.534 uV 09:54:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.890 uVs 09:54:30 Integrated Voltage Measurement... 09:54:39 Voltage Offset Correction: v_off_ini = 2701.852 uV, v_off_fin = 2709.414 uV 09:54:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 28.978 uVs 09:54:39 Integrated Voltage Measurement... 09:54:48 Voltage Offset Correction: v_off_ini = 2698.406 uV, v_off_fin = 2697.587 uV 09:54:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.720 uVs 09:54:48 Integrated Voltage Measurement... 09:54:57 Voltage Offset Correction: v_off_ini = 2688.702 uV, v_off_fin = 2725.580 uV 09:54:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.398 uVs 09:54:57 Integrated Voltage Measurement... 09:55:06 Voltage Offset Correction: v_off_ini = 2738.710 uV, v_off_fin = 2707.445 uV 09:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.931 uVs 09:55:06 Integrated Voltage Measurement... 09:55:15 Voltage Offset Correction: v_off_ini = 2704.777 uV, v_off_fin = 2697.438 uV 09:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.703 uVs 09:55:18 I2X Average and RMS of Measurements VT = -58.436 +- 14.898 uVs I2X = 5.376 +- 1.370 uTm^2 09:55:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:55:26 Integrated Voltage Measurement... 09:55:35 Voltage Offset Correction: v_off_ini = 2696.953 uV, v_off_fin = 2694.841 uV 09:55:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.459 uVs 09:55:35 Integrated Voltage Measurement... 09:55:44 Voltage Offset Correction: v_off_ini = 2704.699 uV, v_off_fin = 2652.782 uV 09:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.829 uVs 09:55:44 Integrated Voltage Measurement... 09:55:53 Voltage Offset Correction: v_off_ini = 2663.965 uV, v_off_fin = 2682.863 uV 09:55:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.120 uVs 09:55:53 Integrated Voltage Measurement... 09:56:02 Voltage Offset Correction: v_off_ini = 2686.269 uV, v_off_fin = 2654.551 uV 09:56:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.426 uVs 09:56:02 Integrated Voltage Measurement... 09:56:11 Voltage Offset Correction: v_off_ini = 2687.840 uV, v_off_fin = 2693.719 uV 09:56:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.820 uVs 09:56:11 Integrated Voltage Measurement... 09:56:20 Voltage Offset Correction: v_off_ini = 2672.057 uV, v_off_fin = 2673.622 uV 09:56:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 365.216 uVs 09:56:22 I2Y Average and RMS of Measurements VT = -355.812 +- 4.864 uVs I2Y = -32.735 +- 0.448 uTm^2 09:56:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:56:37 Integrated Voltage Measurement... 09:56:46 Voltage Offset Correction: v_off_ini = 2656.539 uV, v_off_fin = 2651.909 uV 09:56:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -85.498 uVs 09:56:46 Integrated Voltage Measurement... 09:56:55 Voltage Offset Correction: v_off_ini = 2686.418 uV, v_off_fin = 2700.973 uV 09:56:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.736 uVs 09:56:55 Integrated Voltage Measurement... 09:57:04 Voltage Offset Correction: v_off_ini = 2702.142 uV, v_off_fin = 2691.141 uV 09:57:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.424 uVs 09:57:04 Integrated Voltage Measurement... 09:57:13 Voltage Offset Correction: v_off_ini = 2705.251 uV, v_off_fin = 2651.397 uV 09:57:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.509 uVs 09:57:13 Integrated Voltage Measurement... 09:57:22 Voltage Offset Correction: v_off_ini = 2668.394 uV, v_off_fin = 2663.371 uV 09:57:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.989 uVs 09:57:22 Integrated Voltage Measurement... 09:57:31 Voltage Offset Correction: v_off_ini = 2660.184 uV, v_off_fin = 2719.524 uV 09:57:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.628 uVs 09:57:35 I1X Average and RMS of Measurements VT = -68.131 +- 10.271 uVs I1X = 13.627 +- 2.055 uTm 09:57:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:57:42 Integrated Voltage Measurement... 09:57:51 Voltage Offset Correction: v_off_ini = 2691.055 uV, v_off_fin = 2667.396 uV 09:57:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.159 uVs 09:57:51 Integrated Voltage Measurement... 09:58:00 Voltage Offset Correction: v_off_ini = 2669.637 uV, v_off_fin = 2671.504 uV 09:58:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.333 uVs 09:58:00 Integrated Voltage Measurement... 09:58:09 Voltage Offset Correction: v_off_ini = 2656.529 uV, v_off_fin = 2663.526 uV 09:58:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.269 uVs 09:58:09 Integrated Voltage Measurement... 09:58:18 Voltage Offset Correction: v_off_ini = 2666.390 uV, v_off_fin = 2678.972 uV 09:58:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.810 uVs 09:58:18 Integrated Voltage Measurement... 09:58:27 Voltage Offset Correction: v_off_ini = 2669.897 uV, v_off_fin = 2662.672 uV 09:58:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.898 uVs 09:58:27 Integrated Voltage Measurement... 09:58:36 Voltage Offset Correction: v_off_ini = 2690.463 uV, v_off_fin = 2661.463 uV 09:58:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.767 uVs 09:58:40 I1Y Average and RMS of Measurements VT = -209.706 +- 14.290 uVs I1Y = -41.941 +- 2.858 uTm 09:58:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:58:48 Integrated Voltage Measurement... 09:58:57 Voltage Offset Correction: v_off_ini = 2671.554 uV, v_off_fin = 2710.087 uV 09:58:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.575 uVs 09:58:57 Integrated Voltage Measurement... 09:59:06 Voltage Offset Correction: v_off_ini = 2714.698 uV, v_off_fin = 2740.505 uV 09:59:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.431 uVs 09:59:06 Integrated Voltage Measurement... 09:59:15 Voltage Offset Correction: v_off_ini = 2712.267 uV, v_off_fin = 2727.951 uV 09:59:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.992 uVs 09:59:15 Integrated Voltage Measurement... 09:59:24 Voltage Offset Correction: v_off_ini = 2731.083 uV, v_off_fin = 2747.702 uV 09:59:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.448 uVs 09:59:24 Integrated Voltage Measurement... 09:59:33 Voltage Offset Correction: v_off_ini = 2741.724 uV, v_off_fin = 2713.527 uV 09:59:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.284 uVs 09:59:33 Integrated Voltage Measurement... 09:59:42 Voltage Offset Correction: v_off_ini = 2723.054 uV, v_off_fin = 2740.023 uV 09:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.598 uVs 09:59:44 I2X Average and RMS of Measurements VT = -55.221 +- 7.966 uVs I2X = 5.080 +- 0.733 uTm^2 09:59:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:59:52 Integrated Voltage Measurement... 10:00:01 Voltage Offset Correction: v_off_ini = 2769.300 uV, v_off_fin = 2754.112 uV 10:00:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.120 uVs 10:00:01 Integrated Voltage Measurement... 10:00:10 Voltage Offset Correction: v_off_ini = 2744.561 uV, v_off_fin = 2734.853 uV 10:00:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.768 uVs 10:00:10 Integrated Voltage Measurement... 10:00:19 Voltage Offset Correction: v_off_ini = 2762.803 uV, v_off_fin = 2761.104 uV 10:00:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.506 uVs 10:00:19 Integrated Voltage Measurement... 10:00:28 Voltage Offset Correction: v_off_ini = 2743.091 uV, v_off_fin = 2752.052 uV 10:00:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 314.844 uVs 10:00:28 Integrated Voltage Measurement... 10:00:37 Voltage Offset Correction: v_off_ini = 2775.798 uV, v_off_fin = 2753.350 uV 10:00:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.882 uVs 10:00:37 Integrated Voltage Measurement... 10:00:46 Voltage Offset Correction: v_off_ini = 2754.729 uV, v_off_fin = 2779.985 uV 10:00:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.817 uVs 10:00:49 I2Y Average and RMS of Measurements VT = -336.156 +- 10.318 uVs I2Y = -30.927 +- 0.949 uTm^2 10:00:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:01:04 Integrated Voltage Measurement... 10:01:13 Voltage Offset Correction: v_off_ini = 2745.757 uV, v_off_fin = 2755.954 uV 10:01:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -84.759 uVs 10:01:13 Integrated Voltage Measurement... 10:01:22 Voltage Offset Correction: v_off_ini = 2740.568 uV, v_off_fin = 2746.730 uV 10:01:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.361 uVs 10:01:22 Integrated Voltage Measurement... 10:01:31 Voltage Offset Correction: v_off_ini = 2738.757 uV, v_off_fin = 2707.871 uV 10:01:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.873 uVs 10:01:31 Integrated Voltage Measurement... 10:01:40 Voltage Offset Correction: v_off_ini = 2740.623 uV, v_off_fin = 2734.037 uV 10:01:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.998 uVs 10:01:40 Integrated Voltage Measurement... 10:01:49 Voltage Offset Correction: v_off_ini = 2727.039 uV, v_off_fin = 2723.500 uV 10:01:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.946 uVs 10:01:49 Integrated Voltage Measurement... 10:01:58 Voltage Offset Correction: v_off_ini = 2710.225 uV, v_off_fin = 2723.145 uV 10:01:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.340 uVs 10:02:02 I1X Average and RMS of Measurements VT = -81.046 +- 2.912 uVs I1X = 16.210 +- 0.582 uTm 10:02:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:02:09 Integrated Voltage Measurement... 10:02:17 Voltage Offset Correction: v_off_ini = 2733.833 uV, v_off_fin = 2734.354 uV 10:02:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.760 uVs 10:02:17 Integrated Voltage Measurement... 10:02:26 Voltage Offset Correction: v_off_ini = 2746.760 uV, v_off_fin = 2735.624 uV 10:02:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.872 uVs 10:02:26 Integrated Voltage Measurement... 10:02:35 Voltage Offset Correction: v_off_ini = 2742.023 uV, v_off_fin = 2751.838 uV 10:02:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.795 uVs 10:02:35 Integrated Voltage Measurement... 10:02:44 Voltage Offset Correction: v_off_ini = 2727.097 uV, v_off_fin = 2747.646 uV 10:02:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.300 uVs 10:02:44 Integrated Voltage Measurement... 10:02:53 Voltage Offset Correction: v_off_ini = 2746.899 uV, v_off_fin = 2740.709 uV 10:02:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.518 uVs 10:02:53 Integrated Voltage Measurement... 10:03:02 Voltage Offset Correction: v_off_ini = 2729.098 uV, v_off_fin = 2746.566 uV 10:03:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.133 uVs 10:03:07 I1Y Average and RMS of Measurements VT = -200.896 +- 7.328 uVs I1Y = -40.179 +- 1.466 uTm 10:03:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:03:14 Integrated Voltage Measurement... 10:03:23 Voltage Offset Correction: v_off_ini = 2731.203 uV, v_off_fin = 2727.906 uV 10:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.598 uVs 10:03:23 Integrated Voltage Measurement... 10:03:32 Voltage Offset Correction: v_off_ini = 2749.476 uV, v_off_fin = 2766.901 uV 10:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.485 uVs 10:03:32 Integrated Voltage Measurement... 10:03:41 Voltage Offset Correction: v_off_ini = 2739.947 uV, v_off_fin = 2709.618 uV 10:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.181 uVs 10:03:41 Integrated Voltage Measurement... 10:03:50 Voltage Offset Correction: v_off_ini = 2734.628 uV, v_off_fin = 2723.362 uV 10:03:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.809 uVs 10:03:50 Integrated Voltage Measurement... 10:03:59 Voltage Offset Correction: v_off_ini = 2716.307 uV, v_off_fin = 2717.808 uV 10:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.868 uVs 10:03:59 Integrated Voltage Measurement... 10:04:08 Voltage Offset Correction: v_off_ini = 2713.217 uV, v_off_fin = 2732.910 uV 10:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.985 uVs 10:04:11 I2X Average and RMS of Measurements VT = -58.321 +- 6.466 uVs I2X = 5.366 +- 0.595 uTm^2 10:04:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:04:18 Integrated Voltage Measurement... 10:04:27 Voltage Offset Correction: v_off_ini = 2713.704 uV, v_off_fin = 2698.556 uV 10:04:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -333.177 uVs 10:04:27 Integrated Voltage Measurement... 10:04:36 Voltage Offset Correction: v_off_ini = 2709.517 uV, v_off_fin = 2724.909 uV 10:04:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.291 uVs 10:04:36 Integrated Voltage Measurement... 10:04:45 Voltage Offset Correction: v_off_ini = 2733.454 uV, v_off_fin = 2720.632 uV 10:04:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.939 uVs 10:04:45 Integrated Voltage Measurement... 10:04:54 Voltage Offset Correction: v_off_ini = 2696.566 uV, v_off_fin = 2712.884 uV 10:04:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.370 uVs 10:04:54 Integrated Voltage Measurement... 10:05:03 Voltage Offset Correction: v_off_ini = 2702.995 uV, v_off_fin = 2739.295 uV 10:05:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -314.336 uVs 10:05:03 Integrated Voltage Measurement... 10:05:12 Voltage Offset Correction: v_off_ini = 2726.333 uV, v_off_fin = 2742.929 uV 10:05:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.389 uVs 10:05:15 I2Y Average and RMS of Measurements VT = -323.584 +- 3.826 uVs I2Y = -29.770 +- 0.351 uTm^2 10:05:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:05:30 Integrated Voltage Measurement... 10:05:39 Voltage Offset Correction: v_off_ini = 2752.297 uV, v_off_fin = 2746.593 uV 10:05:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -85.127 uVs 10:05:39 Integrated Voltage Measurement... 10:05:48 Voltage Offset Correction: v_off_ini = 2746.778 uV, v_off_fin = 2754.442 uV 10:05:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.897 uVs 10:05:48 Integrated Voltage Measurement... 10:05:57 Voltage Offset Correction: v_off_ini = 2730.894 uV, v_off_fin = 2714.095 uV 10:05:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.550 uVs 10:05:57 Integrated Voltage Measurement... 10:06:06 Voltage Offset Correction: v_off_ini = 2705.793 uV, v_off_fin = 2726.284 uV 10:06:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.753 uVs 10:06:06 Integrated Voltage Measurement... 10:06:15 Voltage Offset Correction: v_off_ini = 2713.031 uV, v_off_fin = 2728.302 uV 10:06:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.772 uVs 10:06:15 Integrated Voltage Measurement... 10:06:24 Voltage Offset Correction: v_off_ini = 2730.639 uV, v_off_fin = 2716.856 uV 10:06:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.913 uVs 10:06:28 I1X Average and RMS of Measurements VT = -71.502 +- 13.772 uVs I1X = 14.301 +- 2.754 uTm 10:06:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:06:35 Integrated Voltage Measurement... 10:06:44 Voltage Offset Correction: v_off_ini = 2760.837 uV, v_off_fin = 2744.393 uV 10:06:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.143 uVs 10:06:44 Integrated Voltage Measurement... 10:06:53 Voltage Offset Correction: v_off_ini = 2744.864 uV, v_off_fin = 2763.853 uV 10:06:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.624 uVs 10:06:53 Integrated Voltage Measurement... 10:07:02 Voltage Offset Correction: v_off_ini = 2734.036 uV, v_off_fin = 2733.902 uV 10:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.128 uVs 10:07:02 Integrated Voltage Measurement... 10:07:10 Voltage Offset Correction: v_off_ini = 2760.191 uV, v_off_fin = 2772.317 uV 10:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.397 uVs 10:07:11 Integrated Voltage Measurement... 10:07:19 Voltage Offset Correction: v_off_ini = 2755.930 uV, v_off_fin = 2737.280 uV 10:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.410 uVs 10:07:20 Integrated Voltage Measurement... 10:07:28 Voltage Offset Correction: v_off_ini = 2743.993 uV, v_off_fin = 2739.203 uV 10:07:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.516 uVs 10:07:33 I1Y Average and RMS of Measurements VT = -206.203 +- 5.217 uVs I1Y = -41.241 +- 1.043 uTm 10:07:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:07:40 Integrated Voltage Measurement... 10:07:49 Voltage Offset Correction: v_off_ini = 2734.128 uV, v_off_fin = 2758.681 uV 10:07:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -50.900 uVs 10:07:49 Integrated Voltage Measurement... 10:07:58 Voltage Offset Correction: v_off_ini = 2740.115 uV, v_off_fin = 2743.366 uV 10:07:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.344 uVs 10:07:58 Integrated Voltage Measurement... 10:08:07 Voltage Offset Correction: v_off_ini = 2752.093 uV, v_off_fin = 2737.260 uV 10:08:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.377 uVs 10:08:07 Integrated Voltage Measurement... 10:08:16 Voltage Offset Correction: v_off_ini = 2738.527 uV, v_off_fin = 2755.148 uV 10:08:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.882 uVs 10:08:16 Integrated Voltage Measurement... 10:08:25 Voltage Offset Correction: v_off_ini = 2742.879 uV, v_off_fin = 2729.439 uV 10:08:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.630 uVs 10:08:25 Integrated Voltage Measurement... 10:08:34 Voltage Offset Correction: v_off_ini = 2741.115 uV, v_off_fin = 2778.587 uV 10:08:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.867 uVs 10:08:37 I2X Average and RMS of Measurements VT = -68.333 +- 14.870 uVs I2X = 6.287 +- 1.368 uTm^2 10:08:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:08:44 Integrated Voltage Measurement... 10:08:53 Voltage Offset Correction: v_off_ini = 2749.095 uV, v_off_fin = 2752.352 uV 10:08:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.638 uVs 10:08:53 Integrated Voltage Measurement... 10:09:02 Voltage Offset Correction: v_off_ini = 2756.551 uV, v_off_fin = 2756.672 uV 10:09:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 320.843 uVs 10:09:02 Integrated Voltage Measurement... 10:09:11 Voltage Offset Correction: v_off_ini = 2763.120 uV, v_off_fin = 2747.704 uV 10:09:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.084 uVs 10:09:11 Integrated Voltage Measurement... 10:09:20 Voltage Offset Correction: v_off_ini = 2764.597 uV, v_off_fin = 2778.717 uV 10:09:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.617 uVs 10:09:21 Integrated Voltage Measurement... 10:09:29 Voltage Offset Correction: v_off_ini = 2765.955 uV, v_off_fin = 2764.119 uV 10:09:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.261 uVs 10:09:30 Integrated Voltage Measurement... 10:09:39 Voltage Offset Correction: v_off_ini = 2810.305 uV, v_off_fin = 2802.824 uV 10:09:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.501 uVs 10:09:41 I2Y Average and RMS of Measurements VT = -317.657 +- 6.200 uVs I2Y = -29.225 +- 0.571 uTm^2 10:09:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:09:56 Integrated Voltage Measurement... 10:10:05 Voltage Offset Correction: v_off_ini = 2792.353 uV, v_off_fin = 2782.074 uV 10:10:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.505 uVs 10:10:05 Integrated Voltage Measurement... 10:10:14 Voltage Offset Correction: v_off_ini = 2772.815 uV, v_off_fin = 2812.873 uV 10:10:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.181 uVs 10:10:14 Integrated Voltage Measurement... 10:10:23 Voltage Offset Correction: v_off_ini = 2805.370 uV, v_off_fin = 2810.260 uV 10:10:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.829 uVs 10:10:23 Integrated Voltage Measurement... 10:10:32 Voltage Offset Correction: v_off_ini = 2781.953 uV, v_off_fin = 2805.517 uV 10:10:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.565 uVs 10:10:32 Integrated Voltage Measurement... 10:10:41 Voltage Offset Correction: v_off_ini = 2794.280 uV, v_off_fin = 2804.164 uV 10:10:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.904 uVs 10:10:41 Integrated Voltage Measurement... 10:10:50 Voltage Offset Correction: v_off_ini = 2806.570 uV, v_off_fin = 2814.762 uV 10:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.097 uVs 10:10:54 I1X Average and RMS of Measurements VT = -73.513 +- 10.373 uVs I1X = 14.703 +- 2.074 uTm 10:10:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:11:01 Integrated Voltage Measurement... 10:11:10 Voltage Offset Correction: v_off_ini = 2837.131 uV, v_off_fin = 2822.592 uV 10:11:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.338 uVs 10:11:10 Integrated Voltage Measurement... 10:11:19 Voltage Offset Correction: v_off_ini = 2816.923 uV, v_off_fin = 2859.290 uV 10:11:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.226 uVs 10:11:19 Integrated Voltage Measurement... 10:11:28 Voltage Offset Correction: v_off_ini = 2818.052 uV, v_off_fin = 2814.136 uV 10:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.344 uVs 10:11:28 Integrated Voltage Measurement... 10:11:37 Voltage Offset Correction: v_off_ini = 2846.452 uV, v_off_fin = 2836.338 uV 10:11:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.356 uVs 10:11:37 Integrated Voltage Measurement... 10:11:46 Voltage Offset Correction: v_off_ini = 2812.115 uV, v_off_fin = 2822.003 uV 10:11:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.161 uVs 10:11:46 Integrated Voltage Measurement... 10:11:55 Voltage Offset Correction: v_off_ini = 2840.978 uV, v_off_fin = 2841.832 uV 10:11:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.674 uVs 10:11:59 I1Y Average and RMS of Measurements VT = -195.016 +- 2.664 uVs I1Y = -39.001 +- 0.534 uTm 10:12:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:12:07 Integrated Voltage Measurement... 10:12:16 Voltage Offset Correction: v_off_ini = 2783.591 uV, v_off_fin = 2786.674 uV 10:12:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 9.908 uVs 10:12:16 Integrated Voltage Measurement... 10:12:25 Voltage Offset Correction: v_off_ini = 2820.246 uV, v_off_fin = 2832.416 uV 10:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.787 uVs 10:12:25 Integrated Voltage Measurement... 10:12:34 Voltage Offset Correction: v_off_ini = 2810.187 uV, v_off_fin = 2797.724 uV 10:12:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.887 uVs 10:12:34 Integrated Voltage Measurement... 10:12:43 Voltage Offset Correction: v_off_ini = 2837.970 uV, v_off_fin = 2824.207 uV 10:12:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.236 uVs 10:12:43 Integrated Voltage Measurement... 10:12:52 Voltage Offset Correction: v_off_ini = 2838.352 uV, v_off_fin = 2824.004 uV 10:12:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.122 uVs 10:12:52 Integrated Voltage Measurement... 10:13:01 Voltage Offset Correction: v_off_ini = 2847.964 uV, v_off_fin = 2845.725 uV 10:13:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.736 uVs 10:13:03 I2X Average and RMS of Measurements VT = -61.643 +- 19.890 uVs I2X = 5.671 +- 1.830 uTm^2 10:13:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:13:11 Integrated Voltage Measurement... 10:13:20 Voltage Offset Correction: v_off_ini = 2810.844 uV, v_off_fin = 2807.866 uV 10:13:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.626 uVs 10:13:20 Integrated Voltage Measurement... 10:13:29 Voltage Offset Correction: v_off_ini = 2788.977 uV, v_off_fin = 2834.139 uV 10:13:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.481 uVs 10:13:29 Integrated Voltage Measurement... 10:13:38 Voltage Offset Correction: v_off_ini = 2824.334 uV, v_off_fin = 2806.131 uV 10:13:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.931 uVs 10:13:38 Integrated Voltage Measurement... 10:13:47 Voltage Offset Correction: v_off_ini = 2768.182 uV, v_off_fin = 2798.434 uV 10:13:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 312.245 uVs 10:13:47 Integrated Voltage Measurement... 10:13:56 Voltage Offset Correction: v_off_ini = 2799.516 uV, v_off_fin = 2830.110 uV 10:13:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.892 uVs 10:13:56 Integrated Voltage Measurement... 10:14:05 Voltage Offset Correction: v_off_ini = 2815.024 uV, v_off_fin = 2826.623 uV 10:14:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.160 uVs 10:14:07 I2Y Average and RMS of Measurements VT = -317.556 +- 10.566 uVs I2Y = -29.216 +- 0.971 uTm^2 10:14:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:14:22 Integrated Voltage Measurement... 10:14:31 Voltage Offset Correction: v_off_ini = 2836.355 uV, v_off_fin = 2810.609 uV 10:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.639 uVs 10:14:31 Integrated Voltage Measurement... 10:14:40 Voltage Offset Correction: v_off_ini = 2823.978 uV, v_off_fin = 2833.805 uV 10:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.298 uVs 10:14:40 Integrated Voltage Measurement... 10:14:49 Voltage Offset Correction: v_off_ini = 2814.251 uV, v_off_fin = 2826.831 uV 10:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.614 uVs 10:14:49 Integrated Voltage Measurement... 10:14:58 Voltage Offset Correction: v_off_ini = 2821.657 uV, v_off_fin = 2822.065 uV 10:14:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.099 uVs 10:14:58 Integrated Voltage Measurement... 10:15:07 Voltage Offset Correction: v_off_ini = 2812.328 uV, v_off_fin = 2806.148 uV 10:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.310 uVs 10:15:07 Integrated Voltage Measurement... 10:15:16 Voltage Offset Correction: v_off_ini = 2806.247 uV, v_off_fin = 2813.078 uV 10:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.464 uVs 10:15:20 I1X Average and RMS of Measurements VT = -65.237 +- 4.140 uVs I1X = 13.048 +- 0.828 uTm 10:15:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:15:27 Integrated Voltage Measurement... 10:15:36 Voltage Offset Correction: v_off_ini = 2845.442 uV, v_off_fin = 2825.393 uV 10:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -157.200 uVs 10:15:36 Integrated Voltage Measurement... 10:15:45 Voltage Offset Correction: v_off_ini = 2827.753 uV, v_off_fin = 2851.259 uV 10:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.124 uVs 10:15:45 Integrated Voltage Measurement... 10:15:54 Voltage Offset Correction: v_off_ini = 2829.166 uV, v_off_fin = 2819.187 uV 10:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.369 uVs 10:15:54 Integrated Voltage Measurement... 10:16:03 Voltage Offset Correction: v_off_ini = 2824.931 uV, v_off_fin = 2832.866 uV 10:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.280 uVs 10:16:03 Integrated Voltage Measurement... 10:16:12 Voltage Offset Correction: v_off_ini = 2813.755 uV, v_off_fin = 2811.500 uV 10:16:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.918 uVs 10:16:12 Integrated Voltage Measurement... 10:16:21 Voltage Offset Correction: v_off_ini = 2815.383 uV, v_off_fin = 2793.357 uV 10:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.677 uVs 10:16:25 I1Y Average and RMS of Measurements VT = -186.428 +- 4.504 uVs I1Y = -37.284 +- 0.902 uTm 10:16:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:16:33 Integrated Voltage Measurement... 10:16:42 Voltage Offset Correction: v_off_ini = 2777.302 uV, v_off_fin = 2791.014 uV 10:16:42 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -118.929 uVs 10:16:42 Integrated Voltage Measurement... 10:16:51 Voltage Offset Correction: v_off_ini = 2819.119 uV, v_off_fin = 2827.761 uV 10:16:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.014 uVs 10:16:51 Integrated Voltage Measurement... 10:17:00 Voltage Offset Correction: v_off_ini = 2832.837 uV, v_off_fin = 2818.738 uV 10:17:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -147.506 uVs 10:17:00 Integrated Voltage Measurement... 10:17:09 Voltage Offset Correction: v_off_ini = 2831.479 uV, v_off_fin = 2851.771 uV 10:17:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.995 uVs 10:17:09 Integrated Voltage Measurement... 10:17:18 Voltage Offset Correction: v_off_ini = 2834.383 uV, v_off_fin = 2803.664 uV 10:17:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.177 uVs 10:17:18 Integrated Voltage Measurement... 10:17:27 Voltage Offset Correction: v_off_ini = 2854.958 uV, v_off_fin = 2853.962 uV 10:17:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.499 uVs 10:17:30 I2X Average and RMS of Measurements VT = -83.020 +- 15.657 uVs I2X = 7.638 +- 1.440 uTm^2 10:17:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:17:37 Integrated Voltage Measurement... 10:17:46 Voltage Offset Correction: v_off_ini = 2789.778 uV, v_off_fin = 2805.463 uV 10:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.892 uVs 10:17:46 Integrated Voltage Measurement... 10:17:55 Voltage Offset Correction: v_off_ini = 2781.637 uV, v_off_fin = 2813.816 uV 10:17:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.571 uVs 10:17:55 Integrated Voltage Measurement... 10:18:04 Voltage Offset Correction: v_off_ini = 2858.410 uV, v_off_fin = 2822.741 uV 10:18:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.037 uVs 10:18:04 Integrated Voltage Measurement... 10:18:13 Voltage Offset Correction: v_off_ini = 2837.316 uV, v_off_fin = 2817.593 uV 10:18:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.482 uVs 10:18:13 Integrated Voltage Measurement... 10:18:22 Voltage Offset Correction: v_off_ini = 2848.783 uV, v_off_fin = 2830.564 uV 10:18:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.954 uVs 10:18:22 Integrated Voltage Measurement... 10:18:31 Voltage Offset Correction: v_off_ini = 2839.437 uV, v_off_fin = 2816.515 uV 10:18:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.938 uVs 10:18:34 I2Y Average and RMS of Measurements VT = -315.812 +- 10.626 uVs I2Y = -29.055 +- 0.978 uTm^2 10:18:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:18:49 Integrated Voltage Measurement... 10:18:58 Voltage Offset Correction: v_off_ini = 2829.867 uV, v_off_fin = 2840.573 uV 10:18:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.664 uVs 10:18:58 Integrated Voltage Measurement... 10:19:07 Voltage Offset Correction: v_off_ini = 2823.941 uV, v_off_fin = 2838.111 uV 10:19:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.505 uVs 10:19:07 Integrated Voltage Measurement... 10:19:16 Voltage Offset Correction: v_off_ini = 2805.145 uV, v_off_fin = 2816.374 uV 10:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.950 uVs 10:19:16 Integrated Voltage Measurement... 10:19:25 Voltage Offset Correction: v_off_ini = 2843.050 uV, v_off_fin = 2820.105 uV 10:19:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.768 uVs 10:19:25 Integrated Voltage Measurement... 10:19:34 Voltage Offset Correction: v_off_ini = 2809.786 uV, v_off_fin = 2792.879 uV 10:19:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.929 uVs 10:19:34 Integrated Voltage Measurement... 10:19:43 Voltage Offset Correction: v_off_ini = 2781.771 uV, v_off_fin = 2776.068 uV 10:19:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.768 uVs 10:19:47 I1X Average and RMS of Measurements VT = -64.597 +- 7.055 uVs I1X = 12.919 +- 1.411 uTm 10:19:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:19:54 Integrated Voltage Measurement... 10:20:03 Voltage Offset Correction: v_off_ini = 2769.196 uV, v_off_fin = 2760.230 uV 10:20:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -168.071 uVs 10:20:03 Integrated Voltage Measurement... 10:20:12 Voltage Offset Correction: v_off_ini = 2773.595 uV, v_off_fin = 2767.218 uV 10:20:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.263 uVs 10:20:12 Integrated Voltage Measurement... 10:20:21 Voltage Offset Correction: v_off_ini = 2754.570 uV, v_off_fin = 2757.756 uV 10:20:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.958 uVs 10:20:21 Integrated Voltage Measurement... 10:20:30 Voltage Offset Correction: v_off_ini = 2758.605 uV, v_off_fin = 2798.520 uV 10:20:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.412 uVs 10:20:30 Integrated Voltage Measurement... 10:20:39 Voltage Offset Correction: v_off_ini = 2760.937 uV, v_off_fin = 2754.398 uV 10:20:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.147 uVs 10:20:39 Integrated Voltage Measurement... 10:20:48 Voltage Offset Correction: v_off_ini = 2757.642 uV, v_off_fin = 2755.505 uV 10:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.308 uVs 10:20:52 I1Y Average and RMS of Measurements VT = -188.527 +- 14.841 uVs I1Y = -37.706 +- 2.967 uTm 10:20:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:21:00 Integrated Voltage Measurement... 10:21:09 Voltage Offset Correction: v_off_ini = 2732.331 uV, v_off_fin = 2727.623 uV 10:21:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -37.938 uVs 10:21:09 Integrated Voltage Measurement... 10:21:18 Voltage Offset Correction: v_off_ini = 2761.972 uV, v_off_fin = 2763.067 uV 10:21:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.852 uVs 10:21:18 Integrated Voltage Measurement... 10:21:27 Voltage Offset Correction: v_off_ini = 2740.957 uV, v_off_fin = 2748.247 uV 10:21:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.290 uVs 10:21:27 Integrated Voltage Measurement... 10:21:36 Voltage Offset Correction: v_off_ini = 2762.420 uV, v_off_fin = 2760.227 uV 10:21:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.797 uVs 10:21:36 Integrated Voltage Measurement... 10:21:45 Voltage Offset Correction: v_off_ini = 2751.765 uV, v_off_fin = 2721.827 uV 10:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.990 uVs 10:21:45 Integrated Voltage Measurement... 10:21:54 Voltage Offset Correction: v_off_ini = 2750.584 uV, v_off_fin = 2769.162 uV 10:21:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.162 uVs 10:21:56 I2X Average and RMS of Measurements VT = -67.005 +- 0.833 uVs I2X = 6.164 +- 0.077 uTm^2 10:22:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:22:04 Integrated Voltage Measurement... 10:22:13 Voltage Offset Correction: v_off_ini = 2775.578 uV, v_off_fin = 2761.459 uV 10:22:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.486 uVs 10:22:13 Integrated Voltage Measurement... 10:22:22 Voltage Offset Correction: v_off_ini = 2748.151 uV, v_off_fin = 2764.407 uV 10:22:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.968 uVs 10:22:22 Integrated Voltage Measurement... 10:22:31 Voltage Offset Correction: v_off_ini = 2754.112 uV, v_off_fin = 2775.832 uV 10:22:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.508 uVs 10:22:31 Integrated Voltage Measurement... 10:22:40 Voltage Offset Correction: v_off_ini = 2785.566 uV, v_off_fin = 2807.312 uV 10:22:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.168 uVs 10:22:40 Integrated Voltage Measurement... 10:22:49 Voltage Offset Correction: v_off_ini = 2766.330 uV, v_off_fin = 2784.907 uV 10:22:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.873 uVs 10:22:49 Integrated Voltage Measurement... 10:22:58 Voltage Offset Correction: v_off_ini = 2773.241 uV, v_off_fin = 2776.482 uV 10:22:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.610 uVs 10:23:00 I2Y Average and RMS of Measurements VT = -296.602 +- 9.059 uVs I2Y = -27.287 +- 0.833 uTm^2 10:23:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:23:15 Integrated Voltage Measurement... 10:23:24 Voltage Offset Correction: v_off_ini = 2780.654 uV, v_off_fin = 2773.664 uV 10:23:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -101.439 uVs 10:23:24 Integrated Voltage Measurement... 10:23:33 Voltage Offset Correction: v_off_ini = 2746.381 uV, v_off_fin = 2746.262 uV 10:23:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.284 uVs 10:23:33 Integrated Voltage Measurement... 10:23:42 Voltage Offset Correction: v_off_ini = 2761.582 uV, v_off_fin = 2774.493 uV 10:23:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.543 uVs 10:23:42 Integrated Voltage Measurement... 10:23:51 Voltage Offset Correction: v_off_ini = 2764.792 uV, v_off_fin = 2777.493 uV 10:23:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.768 uVs 10:23:51 Integrated Voltage Measurement... 10:24:00 Voltage Offset Correction: v_off_ini = 2772.104 uV, v_off_fin = 2797.440 uV 10:24:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -5.603 uVs 10:24:00 Integrated Voltage Measurement... 10:24:09 Voltage Offset Correction: v_off_ini = 2788.605 uV, v_off_fin = 2760.593 uV 10:24:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.243 uVs 10:24:14 I1X Average and RMS of Measurements VT = -63.813 +- 25.385 uVs I1X = 12.764 +- 5.079 uTm 10:24:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:24:20 Integrated Voltage Measurement... 10:24:29 Voltage Offset Correction: v_off_ini = 2755.092 uV, v_off_fin = 2727.994 uV 10:24:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -169.344 uVs 10:24:29 Integrated Voltage Measurement... 10:24:38 Voltage Offset Correction: v_off_ini = 2752.015 uV, v_off_fin = 2769.369 uV 10:24:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.012 uVs 10:24:38 Integrated Voltage Measurement... 10:24:47 Voltage Offset Correction: v_off_ini = 2748.833 uV, v_off_fin = 2741.366 uV 10:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.868 uVs 10:24:47 Integrated Voltage Measurement... 10:24:56 Voltage Offset Correction: v_off_ini = 2762.632 uV, v_off_fin = 2750.893 uV 10:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.329 uVs 10:24:56 Integrated Voltage Measurement... 10:25:05 Voltage Offset Correction: v_off_ini = 2752.749 uV, v_off_fin = 2742.071 uV 10:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.778 uVs 10:25:05 Integrated Voltage Measurement... 10:25:14 Voltage Offset Correction: v_off_ini = 2748.423 uV, v_off_fin = 2743.449 uV 10:25:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.094 uVs 10:25:18 I1Y Average and RMS of Measurements VT = -174.071 +- 2.484 uVs I1Y = -34.815 +- 0.498 uTm 10:25:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:25:26 Integrated Voltage Measurement... 10:25:35 Voltage Offset Correction: v_off_ini = 2756.419 uV, v_off_fin = 2748.999 uV 10:25:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.438 uVs 10:25:35 Integrated Voltage Measurement... 10:25:44 Voltage Offset Correction: v_off_ini = 2767.458 uV, v_off_fin = 2755.878 uV 10:25:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.125 uVs 10:25:44 Integrated Voltage Measurement... 10:25:53 Voltage Offset Correction: v_off_ini = 2757.972 uV, v_off_fin = 2754.906 uV 10:25:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.638 uVs 10:25:53 Integrated Voltage Measurement... 10:26:02 Voltage Offset Correction: v_off_ini = 2742.464 uV, v_off_fin = 2739.983 uV 10:26:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 111.251 uVs 10:26:02 Integrated Voltage Measurement... 10:26:11 Voltage Offset Correction: v_off_ini = 2752.914 uV, v_off_fin = 2759.459 uV 10:26:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.086 uVs 10:26:11 Integrated Voltage Measurement... 10:26:20 Voltage Offset Correction: v_off_ini = 2776.436 uV, v_off_fin = 2751.868 uV 10:26:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.400 uVs 10:26:23 I2X Average and RMS of Measurements VT = -83.156 +- 13.308 uVs I2X = 7.651 +- 1.224 uTm^2 10:26:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:26:30 Integrated Voltage Measurement... 10:26:39 Voltage Offset Correction: v_off_ini = 2772.083 uV, v_off_fin = 2754.351 uV 10:26:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.568 uVs 10:26:39 Integrated Voltage Measurement... 10:26:48 Voltage Offset Correction: v_off_ini = 2764.343 uV, v_off_fin = 2765.387 uV 10:26:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.210 uVs 10:26:48 Integrated Voltage Measurement... 10:26:57 Voltage Offset Correction: v_off_ini = 2767.707 uV, v_off_fin = 2749.565 uV 10:26:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.137 uVs 10:26:57 Integrated Voltage Measurement... 10:27:06 Voltage Offset Correction: v_off_ini = 2761.952 uV, v_off_fin = 2756.102 uV 10:27:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.209 uVs 10:27:06 Integrated Voltage Measurement... 10:27:15 Voltage Offset Correction: v_off_ini = 2758.809 uV, v_off_fin = 2754.555 uV 10:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.563 uVs 10:27:15 Integrated Voltage Measurement... 10:27:24 Voltage Offset Correction: v_off_ini = 2741.212 uV, v_off_fin = 2740.559 uV 10:27:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.760 uVs 10:27:27 I2Y Average and RMS of Measurements VT = -292.241 +- 13.688 uVs I2Y = -26.886 +- 1.259 uTm^2 10:27:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:27:42 Integrated Voltage Measurement... 10:27:51 Voltage Offset Correction: v_off_ini = 2739.885 uV, v_off_fin = 2754.074 uV 10:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.310 uVs 10:27:51 Integrated Voltage Measurement... 10:28:00 Voltage Offset Correction: v_off_ini = 2733.661 uV, v_off_fin = 2750.025 uV 10:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.603 uVs 10:28:00 Integrated Voltage Measurement... 10:28:09 Voltage Offset Correction: v_off_ini = 2750.304 uV, v_off_fin = 2741.502 uV 10:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.042 uVs 10:28:09 Integrated Voltage Measurement... 10:28:18 Voltage Offset Correction: v_off_ini = 2717.265 uV, v_off_fin = 2739.976 uV 10:28:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.655 uVs 10:28:18 Integrated Voltage Measurement... 10:28:27 Voltage Offset Correction: v_off_ini = 2719.057 uV, v_off_fin = 2728.948 uV 10:28:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.128 uVs 10:28:27 Integrated Voltage Measurement... 10:28:36 Voltage Offset Correction: v_off_ini = 2718.007 uV, v_off_fin = 2720.409 uV 10:28:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.469 uVs 10:28:40 I1X Average and RMS of Measurements VT = -65.534 +- 6.586 uVs I1X = 13.107 +- 1.317 uTm 10:28:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:28:47 Integrated Voltage Measurement... 10:28:56 Voltage Offset Correction: v_off_ini = 2734.797 uV, v_off_fin = 2712.353 uV 10:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -182.800 uVs 10:28:56 Integrated Voltage Measurement... 10:29:05 Voltage Offset Correction: v_off_ini = 2721.092 uV, v_off_fin = 2724.415 uV 10:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.217 uVs 10:29:05 Integrated Voltage Measurement... 10:29:14 Voltage Offset Correction: v_off_ini = 2726.781 uV, v_off_fin = 2723.547 uV 10:29:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.252 uVs 10:29:14 Integrated Voltage Measurement... 10:29:23 Voltage Offset Correction: v_off_ini = 2718.596 uV, v_off_fin = 2725.320 uV 10:29:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.500 uVs 10:29:23 Integrated Voltage Measurement... 10:29:32 Voltage Offset Correction: v_off_ini = 2726.749 uV, v_off_fin = 2713.100 uV 10:29:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.397 uVs 10:29:32 Integrated Voltage Measurement... 10:29:41 Voltage Offset Correction: v_off_ini = 2725.423 uV, v_off_fin = 2756.622 uV 10:29:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.858 uVs 10:29:45 I1Y Average and RMS of Measurements VT = -184.837 +- 6.231 uVs I1Y = -36.968 +- 1.246 uTm 10:29:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:29:53 Integrated Voltage Measurement... 10:30:02 Voltage Offset Correction: v_off_ini = 2744.858 uV, v_off_fin = 2716.700 uV 10:30:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -111.169 uVs 10:30:02 Integrated Voltage Measurement... 10:30:11 Voltage Offset Correction: v_off_ini = 2758.351 uV, v_off_fin = 2755.274 uV 10:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 9.255 uVs 10:30:11 Integrated Voltage Measurement... 10:30:20 Voltage Offset Correction: v_off_ini = 2756.898 uV, v_off_fin = 2728.765 uV 10:30:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.112 uVs 10:30:20 Integrated Voltage Measurement... 10:30:29 Voltage Offset Correction: v_off_ini = 2733.172 uV, v_off_fin = 2765.219 uV 10:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.630 uVs 10:30:29 Integrated Voltage Measurement... 10:30:38 Voltage Offset Correction: v_off_ini = 2751.938 uV, v_off_fin = 2747.099 uV 10:30:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.816 uVs 10:30:38 Integrated Voltage Measurement... 10:30:47 Voltage Offset Correction: v_off_ini = 2720.482 uV, v_off_fin = 2739.965 uV 10:30:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.377 uVs 10:30:49 I2X Average and RMS of Measurements VT = -78.060 +- 12.738 uVs I2X = 7.181 +- 1.172 uTm^2 10:30:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:30:57 Integrated Voltage Measurement... 10:31:06 Voltage Offset Correction: v_off_ini = 2748.121 uV, v_off_fin = 2728.035 uV 10:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.282 uVs 10:31:06 Integrated Voltage Measurement... 10:31:15 Voltage Offset Correction: v_off_ini = 2734.506 uV, v_off_fin = 2738.845 uV 10:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.311 uVs 10:31:15 Integrated Voltage Measurement... 10:31:24 Voltage Offset Correction: v_off_ini = 2731.863 uV, v_off_fin = 2730.762 uV 10:31:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.600 uVs 10:31:24 Integrated Voltage Measurement... 10:31:33 Voltage Offset Correction: v_off_ini = 2738.464 uV, v_off_fin = 2728.202 uV 10:31:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.275 uVs 10:31:33 Integrated Voltage Measurement... 10:31:42 Voltage Offset Correction: v_off_ini = 2740.211 uV, v_off_fin = 2741.556 uV 10:31:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.923 uVs 10:31:42 Integrated Voltage Measurement... 10:31:51 Voltage Offset Correction: v_off_ini = 2741.789 uV, v_off_fin = 2705.950 uV 10:31:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.965 uVs 10:31:54 I2Y Average and RMS of Measurements VT = -282.393 +- 3.194 uVs I2Y = -25.980 +- 0.294 uTm^2 10:32:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:32:10 Integrated Voltage Measurement... 10:32:19 Voltage Offset Correction: v_off_ini = 2738.709 uV, v_off_fin = 2737.495 uV 10:32:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.455 uVs 10:32:19 Integrated Voltage Measurement... 10:32:28 Voltage Offset Correction: v_off_ini = 2728.044 uV, v_off_fin = 2746.838 uV 10:32:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.687 uVs 10:32:28 Integrated Voltage Measurement... 10:32:37 Voltage Offset Correction: v_off_ini = 2756.302 uV, v_off_fin = 2749.417 uV 10:32:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.079 uVs 10:32:37 Integrated Voltage Measurement... 10:32:46 Voltage Offset Correction: v_off_ini = 2761.652 uV, v_off_fin = 2757.491 uV 10:32:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.523 uVs 10:32:46 Integrated Voltage Measurement... 10:32:55 Voltage Offset Correction: v_off_ini = 2755.993 uV, v_off_fin = 2753.330 uV 10:32:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.010 uVs 10:32:55 Integrated Voltage Measurement... 10:33:04 Voltage Offset Correction: v_off_ini = 2760.331 uV, v_off_fin = 2756.041 uV 10:33:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.129 uVs 10:33:08 I1X Average and RMS of Measurements VT = -73.314 +- 8.062 uVs I1X = 14.663 +- 1.612 uTm 10:33:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:33:15 Integrated Voltage Measurement... 10:33:24 Voltage Offset Correction: v_off_ini = 2732.310 uV, v_off_fin = 2736.289 uV 10:33:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.532 uVs 10:33:24 Integrated Voltage Measurement... 10:33:33 Voltage Offset Correction: v_off_ini = 2749.703 uV, v_off_fin = 2753.487 uV 10:33:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.964 uVs 10:33:33 Integrated Voltage Measurement... 10:33:42 Voltage Offset Correction: v_off_ini = 2748.374 uV, v_off_fin = 2744.800 uV 10:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.725 uVs 10:33:42 Integrated Voltage Measurement... 10:33:51 Voltage Offset Correction: v_off_ini = 2746.122 uV, v_off_fin = 2767.854 uV 10:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.320 uVs 10:33:51 Integrated Voltage Measurement... 10:34:00 Voltage Offset Correction: v_off_ini = 2780.354 uV, v_off_fin = 2731.117 uV 10:34:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.032 uVs 10:34:00 Integrated Voltage Measurement... 10:34:09 Voltage Offset Correction: v_off_ini = 2764.825 uV, v_off_fin = 2810.142 uV 10:34:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.263 uVs 10:34:13 I1Y Average and RMS of Measurements VT = -166.806 +- 13.557 uVs I1Y = -33.361 +- 2.711 uTm 10:34:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:34:21 Integrated Voltage Measurement... 10:34:30 Voltage Offset Correction: v_off_ini = 2772.740 uV, v_off_fin = 2768.087 uV 10:34:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -30.931 uVs 10:34:30 Integrated Voltage Measurement... 10:34:39 Voltage Offset Correction: v_off_ini = 2774.336 uV, v_off_fin = 2792.638 uV 10:34:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.991 uVs 10:34:39 Integrated Voltage Measurement... 10:34:48 Voltage Offset Correction: v_off_ini = 2785.762 uV, v_off_fin = 2755.871 uV 10:34:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.151 uVs 10:34:48 Integrated Voltage Measurement... 10:34:57 Voltage Offset Correction: v_off_ini = 2742.356 uV, v_off_fin = 2761.376 uV 10:34:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.011 uVs 10:34:57 Integrated Voltage Measurement... 10:35:06 Voltage Offset Correction: v_off_ini = 2768.289 uV, v_off_fin = 2736.733 uV 10:35:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.048 uVs 10:35:06 Integrated Voltage Measurement... 10:35:15 Voltage Offset Correction: v_off_ini = 2747.776 uV, v_off_fin = 2770.445 uV 10:35:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 90.351 uVs 10:35:17 I2X Average and RMS of Measurements VT = -65.914 +- 13.391 uVs I2X = 6.064 +- 1.232 uTm^2 10:35:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:35:25 Integrated Voltage Measurement... 10:35:34 Voltage Offset Correction: v_off_ini = 2761.567 uV, v_off_fin = 2730.515 uV 10:35:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.283 uVs 10:35:34 Integrated Voltage Measurement... 10:35:43 Voltage Offset Correction: v_off_ini = 2752.817 uV, v_off_fin = 2772.789 uV 10:35:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.462 uVs 10:35:43 Integrated Voltage Measurement... 10:35:52 Voltage Offset Correction: v_off_ini = 2761.629 uV, v_off_fin = 2763.232 uV 10:35:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.730 uVs 10:35:52 Integrated Voltage Measurement... 10:36:01 Voltage Offset Correction: v_off_ini = 2776.083 uV, v_off_fin = 2759.740 uV 10:36:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 251.217 uVs 10:36:01 Integrated Voltage Measurement... 10:36:10 Voltage Offset Correction: v_off_ini = 2748.088 uV, v_off_fin = 2762.643 uV 10:36:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.055 uVs 10:36:10 Integrated Voltage Measurement... 10:36:19 Voltage Offset Correction: v_off_ini = 2765.920 uV, v_off_fin = 2772.197 uV 10:36:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.401 uVs 10:36:21 I2Y Average and RMS of Measurements VT = -270.025 +- 11.485 uVs I2Y = -24.843 +- 1.056 uTm^2 10:36:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:36:38 Integrated Voltage Measurement... 10:36:46 Voltage Offset Correction: v_off_ini = 2777.396 uV, v_off_fin = 2769.039 uV 10:36:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.695 uVs 10:36:47 Integrated Voltage Measurement... 10:36:55 Voltage Offset Correction: v_off_ini = 2759.187 uV, v_off_fin = 2761.082 uV 10:36:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.175 uVs 10:36:56 Integrated Voltage Measurement... 10:37:04 Voltage Offset Correction: v_off_ini = 2783.379 uV, v_off_fin = 2763.998 uV 10:37:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.552 uVs 10:37:05 Integrated Voltage Measurement... 10:37:13 Voltage Offset Correction: v_off_ini = 2753.488 uV, v_off_fin = 2750.072 uV 10:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.770 uVs 10:37:14 Integrated Voltage Measurement... 10:37:23 Voltage Offset Correction: v_off_ini = 2757.940 uV, v_off_fin = 2777.505 uV 10:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.714 uVs 10:37:23 Integrated Voltage Measurement... 10:37:32 Voltage Offset Correction: v_off_ini = 2763.897 uV, v_off_fin = 2755.932 uV 10:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.190 uVs 10:37:36 I1X Average and RMS of Measurements VT = -94.183 +- 11.244 uVs I1X = 18.837 +- 2.249 uTm 10:37:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:37:42 Integrated Voltage Measurement... 10:37:51 Voltage Offset Correction: v_off_ini = 2761.680 uV, v_off_fin = 2747.261 uV 10:37:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.743 uVs 10:37:51 Integrated Voltage Measurement... 10:38:00 Voltage Offset Correction: v_off_ini = 2775.931 uV, v_off_fin = 2779.541 uV 10:38:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.954 uVs 10:38:00 Integrated Voltage Measurement... 10:38:09 Voltage Offset Correction: v_off_ini = 2759.095 uV, v_off_fin = 2761.792 uV 10:38:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -168.881 uVs 10:38:09 Integrated Voltage Measurement... 10:38:18 Voltage Offset Correction: v_off_ini = 2770.257 uV, v_off_fin = 2799.931 uV 10:38:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.750 uVs 10:38:18 Integrated Voltage Measurement... 10:38:27 Voltage Offset Correction: v_off_ini = 2795.507 uV, v_off_fin = 2770.811 uV 10:38:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.637 uVs 10:38:27 Integrated Voltage Measurement... 10:38:36 Voltage Offset Correction: v_off_ini = 2783.945 uV, v_off_fin = 2798.791 uV 10:38:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 141.239 uVs 10:38:41 I1Y Average and RMS of Measurements VT = -166.534 +- 8.543 uVs I1Y = -33.306 +- 1.709 uTm 10:38:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:38:48 Integrated Voltage Measurement... 10:38:57 Voltage Offset Correction: v_off_ini = 2774.716 uV, v_off_fin = 2767.558 uV 10:38:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.204 uVs 10:38:57 Integrated Voltage Measurement... 10:39:06 Voltage Offset Correction: v_off_ini = 2790.828 uV, v_off_fin = 2815.018 uV 10:39:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.369 uVs 10:39:06 Integrated Voltage Measurement... 10:39:15 Voltage Offset Correction: v_off_ini = 2815.103 uV, v_off_fin = 2800.723 uV 10:39:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.721 uVs 10:39:15 Integrated Voltage Measurement... 10:39:24 Voltage Offset Correction: v_off_ini = 2802.238 uV, v_off_fin = 2810.554 uV 10:39:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.627 uVs 10:39:24 Integrated Voltage Measurement... 10:39:33 Voltage Offset Correction: v_off_ini = 2817.834 uV, v_off_fin = 2783.677 uV 10:39:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.674 uVs 10:39:33 Integrated Voltage Measurement... 10:39:42 Voltage Offset Correction: v_off_ini = 2812.910 uV, v_off_fin = 2801.711 uV 10:39:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 55.246 uVs 10:39:45 I2X Average and RMS of Measurements VT = -81.473 +- 3.974 uVs I2X = 7.496 +- 0.366 uTm^2 10:39:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:39:52 Integrated Voltage Measurement... 10:40:01 Voltage Offset Correction: v_off_ini = 2775.122 uV, v_off_fin = 2807.225 uV 10:40:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.284 uVs 10:40:02 Integrated Voltage Measurement... 10:40:10 Voltage Offset Correction: v_off_ini = 2803.329 uV, v_off_fin = 2784.103 uV 10:40:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.314 uVs 10:40:11 Integrated Voltage Measurement... 10:40:20 Voltage Offset Correction: v_off_ini = 2772.925 uV, v_off_fin = 2791.346 uV 10:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.998 uVs 10:40:20 Integrated Voltage Measurement... 10:40:29 Voltage Offset Correction: v_off_ini = 2780.762 uV, v_off_fin = 2766.080 uV 10:40:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.091 uVs 10:40:29 Integrated Voltage Measurement... 10:40:38 Voltage Offset Correction: v_off_ini = 2770.636 uV, v_off_fin = 2752.294 uV 10:40:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.934 uVs 10:40:38 Integrated Voltage Measurement... 10:40:47 Voltage Offset Correction: v_off_ini = 2793.998 uV, v_off_fin = 2796.595 uV 10:40:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.926 uVs 10:40:49 I2Y Average and RMS of Measurements VT = -242.425 +- 3.026 uVs I2Y = -22.303 +- 0.278 uTm^2 10:41:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:41:08 Integrated Voltage Measurement... 10:41:16 Voltage Offset Correction: v_off_ini = 2774.824 uV, v_off_fin = 2764.601 uV 10:41:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.437 uVs 10:41:17 Integrated Voltage Measurement... 10:41:25 Voltage Offset Correction: v_off_ini = 2757.118 uV, v_off_fin = 2788.610 uV 10:41:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.279 uVs 10:41:26 Integrated Voltage Measurement... 10:41:34 Voltage Offset Correction: v_off_ini = 2777.793 uV, v_off_fin = 2774.592 uV 10:41:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.153 uVs 10:41:35 Integrated Voltage Measurement... 10:41:43 Voltage Offset Correction: v_off_ini = 2798.389 uV, v_off_fin = 2796.774 uV 10:41:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.402 uVs 10:41:44 Integrated Voltage Measurement... 10:41:52 Voltage Offset Correction: v_off_ini = 2783.264 uV, v_off_fin = 2772.130 uV 10:41:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.988 uVs 10:41:53 Integrated Voltage Measurement... 10:42:02 Voltage Offset Correction: v_off_ini = 2796.380 uV, v_off_fin = 2807.419 uV 10:42:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.168 uVs 10:42:06 I1X Average and RMS of Measurements VT = -87.571 +- 13.206 uVs I1X = 17.515 +- 2.641 uTm 10:42:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:42:12 Integrated Voltage Measurement... 10:42:21 Voltage Offset Correction: v_off_ini = 2786.100 uV, v_off_fin = 2806.754 uV 10:42:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.377 uVs 10:42:21 Integrated Voltage Measurement... 10:42:30 Voltage Offset Correction: v_off_ini = 2807.116 uV, v_off_fin = 2821.837 uV 10:42:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.965 uVs 10:42:30 Integrated Voltage Measurement... 10:42:39 Voltage Offset Correction: v_off_ini = 2842.782 uV, v_off_fin = 2802.609 uV 10:42:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.701 uVs 10:42:39 Integrated Voltage Measurement... 10:42:48 Voltage Offset Correction: v_off_ini = 2818.058 uV, v_off_fin = 2817.129 uV 10:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.068 uVs 10:42:49 Integrated Voltage Measurement... 10:42:57 Voltage Offset Correction: v_off_ini = 2820.414 uV, v_off_fin = 2795.802 uV 10:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.836 uVs 10:42:57 Integrated Voltage Measurement... 10:43:06 Voltage Offset Correction: v_off_ini = 2805.779 uV, v_off_fin = 2824.712 uV 10:43:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.050 uVs 10:43:11 I1Y Average and RMS of Measurements VT = -188.999 +- 3.450 uVs I1Y = -37.800 +- 0.690 uTm 10:43:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:43:18 Integrated Voltage Measurement... 10:43:27 Voltage Offset Correction: v_off_ini = 2793.217 uV, v_off_fin = 2808.799 uV 10:43:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.920 uVs 10:43:27 Integrated Voltage Measurement... 10:43:36 Voltage Offset Correction: v_off_ini = 2787.854 uV, v_off_fin = 2799.767 uV 10:43:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.755 uVs 10:43:36 Integrated Voltage Measurement... 10:43:45 Voltage Offset Correction: v_off_ini = 2796.423 uV, v_off_fin = 2781.159 uV 10:43:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.051 uVs 10:43:45 Integrated Voltage Measurement... 10:43:54 Voltage Offset Correction: v_off_ini = 2789.085 uV, v_off_fin = 2793.523 uV 10:43:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.709 uVs 10:43:54 Integrated Voltage Measurement... 10:44:03 Voltage Offset Correction: v_off_ini = 2791.183 uV, v_off_fin = 2792.101 uV 10:44:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.624 uVs 10:44:03 Integrated Voltage Measurement... 10:44:12 Voltage Offset Correction: v_off_ini = 2794.633 uV, v_off_fin = 2799.646 uV 10:44:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.600 uVs 10:44:15 I2X Average and RMS of Measurements VT = -81.277 +- 7.276 uVs I2X = 7.477 +- 0.669 uTm^2 10:44:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:44:23 Integrated Voltage Measurement... 10:44:31 Voltage Offset Correction: v_off_ini = 2763.911 uV, v_off_fin = 2773.822 uV 10:44:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.842 uVs 10:44:32 Integrated Voltage Measurement... 10:44:41 Voltage Offset Correction: v_off_ini = 2767.908 uV, v_off_fin = 2804.604 uV 10:44:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.489 uVs 10:44:41 Integrated Voltage Measurement... 10:44:50 Voltage Offset Correction: v_off_ini = 2767.197 uV, v_off_fin = 2770.735 uV 10:44:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.618 uVs 10:44:50 Integrated Voltage Measurement... 10:44:59 Voltage Offset Correction: v_off_ini = 2802.987 uV, v_off_fin = 2801.387 uV 10:44:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.987 uVs 10:44:59 Integrated Voltage Measurement... 10:45:08 Voltage Offset Correction: v_off_ini = 2791.460 uV, v_off_fin = 2816.251 uV 10:45:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.495 uVs 10:45:08 Integrated Voltage Measurement... 10:45:17 Voltage Offset Correction: v_off_ini = 2792.369 uV, v_off_fin = 2800.043 uV 10:45:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.229 uVs 10:45:19 I2Y Average and RMS of Measurements VT = -259.610 +- 4.067 uVs I2Y = -23.884 +- 0.374 uTm^2 10:45:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:45:38 Integrated Voltage Measurement... 10:45:46 Voltage Offset Correction: v_off_ini = 2799.666 uV, v_off_fin = 2800.077 uV 10:45:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.999 uVs 10:45:47 Integrated Voltage Measurement... 10:45:55 Voltage Offset Correction: v_off_ini = 2810.655 uV, v_off_fin = 2797.858 uV 10:45:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.563 uVs 10:45:56 Integrated Voltage Measurement... 10:46:05 Voltage Offset Correction: v_off_ini = 2783.139 uV, v_off_fin = 2785.507 uV 10:46:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.107 uVs 10:46:05 Integrated Voltage Measurement... 10:46:14 Voltage Offset Correction: v_off_ini = 2774.702 uV, v_off_fin = 2783.331 uV 10:46:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.446 uVs 10:46:14 Integrated Voltage Measurement... 10:46:23 Voltage Offset Correction: v_off_ini = 2828.543 uV, v_off_fin = 2823.115 uV 10:46:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.464 uVs 10:46:23 Integrated Voltage Measurement... 10:46:32 Voltage Offset Correction: v_off_ini = 2793.449 uV, v_off_fin = 2814.939 uV 10:46:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.877 uVs 10:46:36 I1X Average and RMS of Measurements VT = -94.909 +- 4.712 uVs I1X = 18.982 +- 0.942 uTm 10:46:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:46:43 Integrated Voltage Measurement... 10:46:51 Voltage Offset Correction: v_off_ini = 2811.541 uV, v_off_fin = 2789.414 uV 10:46:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -182.558 uVs 10:46:52 Integrated Voltage Measurement... 10:47:00 Voltage Offset Correction: v_off_ini = 2814.729 uV, v_off_fin = 2769.106 uV 10:47:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.202 uVs 10:47:01 Integrated Voltage Measurement... 10:47:09 Voltage Offset Correction: v_off_ini = 2812.809 uV, v_off_fin = 2783.701 uV 10:47:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.825 uVs 10:47:10 Integrated Voltage Measurement... 10:47:18 Voltage Offset Correction: v_off_ini = 2776.959 uV, v_off_fin = 2811.251 uV 10:47:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.868 uVs 10:47:19 Integrated Voltage Measurement... 10:47:27 Voltage Offset Correction: v_off_ini = 2810.305 uV, v_off_fin = 2795.747 uV 10:47:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.684 uVs 10:47:28 Integrated Voltage Measurement... 10:47:36 Voltage Offset Correction: v_off_ini = 2802.930 uV, v_off_fin = 2800.325 uV 10:47:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.492 uVs 10:47:41 I1Y Average and RMS of Measurements VT = -194.438 +- 6.009 uVs I1Y = -38.888 +- 1.203 uTm 10:47:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:47:48 Integrated Voltage Measurement... 10:47:57 Voltage Offset Correction: v_off_ini = 2810.184 uV, v_off_fin = 2799.612 uV 10:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.456 uVs 10:47:57 Integrated Voltage Measurement... 10:48:06 Voltage Offset Correction: v_off_ini = 2799.467 uV, v_off_fin = 2804.290 uV 10:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.166 uVs 10:48:06 Integrated Voltage Measurement... 10:48:15 Voltage Offset Correction: v_off_ini = 2803.052 uV, v_off_fin = 2788.573 uV 10:48:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.845 uVs 10:48:15 Integrated Voltage Measurement... 10:48:24 Voltage Offset Correction: v_off_ini = 2795.993 uV, v_off_fin = 2805.622 uV 10:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.748 uVs 10:48:24 Integrated Voltage Measurement... 10:48:33 Voltage Offset Correction: v_off_ini = 2812.146 uV, v_off_fin = 2803.998 uV 10:48:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.080 uVs 10:48:33 Integrated Voltage Measurement... 10:48:42 Voltage Offset Correction: v_off_ini = 2794.789 uV, v_off_fin = 2810.662 uV 10:48:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.966 uVs 10:48:45 I2X Average and RMS of Measurements VT = -78.044 +- 6.664 uVs I2X = 7.180 +- 0.613 uTm^2 10:48:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:48:53 Integrated Voltage Measurement... 10:49:02 Voltage Offset Correction: v_off_ini = 2817.316 uV, v_off_fin = 2826.666 uV 10:49:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.034 uVs 10:49:02 Integrated Voltage Measurement... 10:49:11 Voltage Offset Correction: v_off_ini = 2813.507 uV, v_off_fin = 2816.040 uV 10:49:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.725 uVs 10:49:11 Integrated Voltage Measurement... 10:49:20 Voltage Offset Correction: v_off_ini = 2804.487 uV, v_off_fin = 2783.001 uV 10:49:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.698 uVs 10:49:20 Integrated Voltage Measurement... 10:49:29 Voltage Offset Correction: v_off_ini = 2796.330 uV, v_off_fin = 2773.075 uV 10:49:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.698 uVs 10:49:29 Integrated Voltage Measurement... 10:49:38 Voltage Offset Correction: v_off_ini = 2794.464 uV, v_off_fin = 2783.127 uV 10:49:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.559 uVs 10:49:38 Integrated Voltage Measurement... 10:49:47 Voltage Offset Correction: v_off_ini = 2799.307 uV, v_off_fin = 2801.926 uV 10:49:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.577 uVs 10:49:49 I2Y Average and RMS of Measurements VT = -275.715 +- 7.281 uVs I2Y = -25.366 +- 0.670 uTm^2 10:50:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:50:08 Integrated Voltage Measurement... 10:50:16 Voltage Offset Correction: v_off_ini = 2788.327 uV, v_off_fin = 2796.894 uV 10:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.064 uVs 10:50:17 Integrated Voltage Measurement... 10:50:26 Voltage Offset Correction: v_off_ini = 2790.443 uV, v_off_fin = 2798.029 uV 10:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.472 uVs 10:50:26 Integrated Voltage Measurement... 10:50:35 Voltage Offset Correction: v_off_ini = 2817.739 uV, v_off_fin = 2823.001 uV 10:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.625 uVs 10:50:35 Integrated Voltage Measurement... 10:50:44 Voltage Offset Correction: v_off_ini = 2829.019 uV, v_off_fin = 2826.521 uV 10:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.547 uVs 10:50:44 Integrated Voltage Measurement... 10:50:53 Voltage Offset Correction: v_off_ini = 2827.288 uV, v_off_fin = 2800.140 uV 10:50:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.708 uVs 10:50:53 Integrated Voltage Measurement... 10:51:02 Voltage Offset Correction: v_off_ini = 2822.239 uV, v_off_fin = 2810.873 uV 10:51:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.906 uVs 10:51:06 I1X Average and RMS of Measurements VT = -87.720 +- 18.653 uVs I1X = 17.544 +- 3.730 uTm 10:51:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:51:13 Integrated Voltage Measurement... 10:51:21 Voltage Offset Correction: v_off_ini = 2793.962 uV, v_off_fin = 2796.372 uV 10:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -170.992 uVs 10:51:22 Integrated Voltage Measurement... 10:51:30 Voltage Offset Correction: v_off_ini = 2793.929 uV, v_off_fin = 2785.523 uV 10:51:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 158.420 uVs 10:51:31 Integrated Voltage Measurement... 10:51:39 Voltage Offset Correction: v_off_ini = 2772.559 uV, v_off_fin = 2758.040 uV 10:51:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.038 uVs 10:51:39 Integrated Voltage Measurement... 10:51:48 Voltage Offset Correction: v_off_ini = 2767.166 uV, v_off_fin = 2778.719 uV 10:51:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.306 uVs 10:51:48 Integrated Voltage Measurement... 10:51:57 Voltage Offset Correction: v_off_ini = 2777.067 uV, v_off_fin = 2754.167 uV 10:51:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.966 uVs 10:51:57 Integrated Voltage Measurement... 10:52:06 Voltage Offset Correction: v_off_ini = 2764.501 uV, v_off_fin = 2788.128 uV 10:52:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.592 uVs 10:52:11 I1Y Average and RMS of Measurements VT = -182.052 +- 12.913 uVs I1Y = -36.409 +- 2.582 uTm 10:52:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:52:18 Integrated Voltage Measurement... 10:52:27 Voltage Offset Correction: v_off_ini = 2757.335 uV, v_off_fin = 2761.503 uV 10:52:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.648 uVs 10:52:27 Integrated Voltage Measurement... 10:52:36 Voltage Offset Correction: v_off_ini = 2790.916 uV, v_off_fin = 2816.558 uV 10:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.829 uVs 10:52:36 Integrated Voltage Measurement... 10:52:45 Voltage Offset Correction: v_off_ini = 2808.105 uV, v_off_fin = 2797.950 uV 10:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.974 uVs 10:52:45 Integrated Voltage Measurement... 10:52:54 Voltage Offset Correction: v_off_ini = 2802.566 uV, v_off_fin = 2802.584 uV 10:52:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.796 uVs 10:52:54 Integrated Voltage Measurement... 10:53:03 Voltage Offset Correction: v_off_ini = 2772.314 uV, v_off_fin = 2757.813 uV 10:53:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.860 uVs 10:53:03 Integrated Voltage Measurement... 10:53:12 Voltage Offset Correction: v_off_ini = 2770.299 uV, v_off_fin = 2772.050 uV 10:53:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 69.704 uVs 10:53:15 I2X Average and RMS of Measurements VT = -82.302 +- 8.398 uVs I2X = 7.572 +- 0.773 uTm^2 10:53:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:53:23 Integrated Voltage Measurement... 10:53:31 Voltage Offset Correction: v_off_ini = 2773.305 uV, v_off_fin = 2779.523 uV 10:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.895 uVs 10:53:32 Integrated Voltage Measurement... 10:53:41 Voltage Offset Correction: v_off_ini = 2797.886 uV, v_off_fin = 2800.587 uV 10:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.004 uVs 10:53:41 Integrated Voltage Measurement... 10:53:50 Voltage Offset Correction: v_off_ini = 2803.257 uV, v_off_fin = 2788.259 uV 10:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.297 uVs 10:53:50 Integrated Voltage Measurement... 10:53:59 Voltage Offset Correction: v_off_ini = 2797.553 uV, v_off_fin = 2793.369 uV 10:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.276 uVs 10:53:59 Integrated Voltage Measurement... 10:54:08 Voltage Offset Correction: v_off_ini = 2794.673 uV, v_off_fin = 2792.967 uV 10:54:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -244.389 uVs 10:54:08 Integrated Voltage Measurement... 10:54:17 Voltage Offset Correction: v_off_ini = 2783.633 uV, v_off_fin = 2794.273 uV 10:54:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.615 uVs 10:54:19 I2Y Average and RMS of Measurements VT = -258.246 +- 11.209 uVs I2Y = -23.759 +- 1.031 uTm^2 10:54:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:54:38 Integrated Voltage Measurement... 10:54:46 Voltage Offset Correction: v_off_ini = 2783.201 uV, v_off_fin = 2813.496 uV 10:54:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.263 uVs 10:54:47 Integrated Voltage Measurement... 10:54:55 Voltage Offset Correction: v_off_ini = 2788.629 uV, v_off_fin = 2808.482 uV 10:54:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.762 uVs 10:54:56 Integrated Voltage Measurement... 10:55:04 Voltage Offset Correction: v_off_ini = 2796.566 uV, v_off_fin = 2800.478 uV 10:55:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.156 uVs 10:55:05 Integrated Voltage Measurement... 10:55:13 Voltage Offset Correction: v_off_ini = 2783.047 uV, v_off_fin = 2815.413 uV 10:55:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.982 uVs 10:55:14 Integrated Voltage Measurement... 10:55:22 Voltage Offset Correction: v_off_ini = 2819.213 uV, v_off_fin = 2805.262 uV 10:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.076 uVs 10:55:23 Integrated Voltage Measurement... 10:55:31 Voltage Offset Correction: v_off_ini = 2842.951 uV, v_off_fin = 2837.402 uV 10:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.097 uVs 10:55:36 I1X Average and RMS of Measurements VT = -83.556 +- 14.519 uVs I1X = 16.711 +- 2.904 uTm 10:55:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:55:42 Integrated Voltage Measurement... 10:55:51 Voltage Offset Correction: v_off_ini = 2813.587 uV, v_off_fin = 2820.651 uV 10:55:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.566 uVs 10:55:51 Integrated Voltage Measurement... 10:56:00 Voltage Offset Correction: v_off_ini = 2827.965 uV, v_off_fin = 2859.051 uV 10:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.616 uVs 10:56:00 Integrated Voltage Measurement... 10:56:09 Voltage Offset Correction: v_off_ini = 2816.153 uV, v_off_fin = 2787.959 uV 10:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.829 uVs 10:56:09 Integrated Voltage Measurement... 10:56:18 Voltage Offset Correction: v_off_ini = 2805.071 uV, v_off_fin = 2812.173 uV 10:56:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.390 uVs 10:56:18 Integrated Voltage Measurement... 10:56:27 Voltage Offset Correction: v_off_ini = 2813.107 uV, v_off_fin = 2804.742 uV 10:56:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.212 uVs 10:56:27 Integrated Voltage Measurement... 10:56:36 Voltage Offset Correction: v_off_ini = 2820.038 uV, v_off_fin = 2812.324 uV 10:56:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.367 uVs 10:56:41 I1Y Average and RMS of Measurements VT = -203.497 +- 1.226 uVs I1Y = -40.699 +- 0.244 uTm 10:56:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:56:48 Integrated Voltage Measurement... 10:56:57 Voltage Offset Correction: v_off_ini = 2804.119 uV, v_off_fin = 2804.482 uV 10:56:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -94.255 uVs 10:56:57 Integrated Voltage Measurement... 10:57:06 Voltage Offset Correction: v_off_ini = 2831.015 uV, v_off_fin = 2834.321 uV 10:57:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.005 uVs 10:57:06 Integrated Voltage Measurement... 10:57:15 Voltage Offset Correction: v_off_ini = 2811.356 uV, v_off_fin = 2822.014 uV 10:57:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.955 uVs 10:57:15 Integrated Voltage Measurement... 10:57:24 Voltage Offset Correction: v_off_ini = 2813.776 uV, v_off_fin = 2835.041 uV 10:57:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.040 uVs 10:57:24 Integrated Voltage Measurement... 10:57:33 Voltage Offset Correction: v_off_ini = 2794.657 uV, v_off_fin = 2827.587 uV 10:57:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.630 uVs 10:57:33 Integrated Voltage Measurement... 10:57:42 Voltage Offset Correction: v_off_ini = 2836.054 uV, v_off_fin = 2844.501 uV 10:57:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.606 uVs 10:57:45 I2X Average and RMS of Measurements VT = -74.582 +- 5.284 uVs I2X = 6.861 +- 0.486 uTm^2 10:57:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:57:52 Integrated Voltage Measurement... 10:58:01 Voltage Offset Correction: v_off_ini = 2812.032 uV, v_off_fin = 2801.322 uV 10:58:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.132 uVs 10:58:02 Integrated Voltage Measurement... 10:58:10 Voltage Offset Correction: v_off_ini = 2837.013 uV, v_off_fin = 2812.137 uV 10:58:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.623 uVs 10:58:11 Integrated Voltage Measurement... 10:58:20 Voltage Offset Correction: v_off_ini = 2830.152 uV, v_off_fin = 2825.252 uV 10:58:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.375 uVs 10:58:20 Integrated Voltage Measurement... 10:58:29 Voltage Offset Correction: v_off_ini = 2810.371 uV, v_off_fin = 2818.659 uV 10:58:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.847 uVs 10:58:29 Integrated Voltage Measurement... 10:58:38 Voltage Offset Correction: v_off_ini = 2859.078 uV, v_off_fin = 2853.717 uV 10:58:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.292 uVs 10:58:38 Integrated Voltage Measurement... 10:58:47 Voltage Offset Correction: v_off_ini = 2858.423 uV, v_off_fin = 2872.750 uV 10:58:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.132 uVs 10:58:49 I2Y Average and RMS of Measurements VT = -244.900 +- 3.922 uVs I2Y = -22.531 +- 0.361 uTm^2 10:59:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:59:07 Integrated Voltage Measurement... 10:59:16 Voltage Offset Correction: v_off_ini = 2849.532 uV, v_off_fin = 2854.419 uV 10:59:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.156 uVs 10:59:16 Integrated Voltage Measurement... 10:59:25 Voltage Offset Correction: v_off_ini = 2867.668 uV, v_off_fin = 2866.579 uV 10:59:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.931 uVs 10:59:26 Integrated Voltage Measurement... 10:59:34 Voltage Offset Correction: v_off_ini = 2824.895 uV, v_off_fin = 2863.562 uV 10:59:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.084 uVs 10:59:35 Integrated Voltage Measurement... 10:59:44 Voltage Offset Correction: v_off_ini = 2872.105 uV, v_off_fin = 2844.739 uV 10:59:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.197 uVs 10:59:44 Integrated Voltage Measurement... 10:59:53 Voltage Offset Correction: v_off_ini = 2841.766 uV, v_off_fin = 2842.047 uV 10:59:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.362 uVs 10:59:53 Integrated Voltage Measurement... 11:00:02 Voltage Offset Correction: v_off_ini = 2846.903 uV, v_off_fin = 2846.172 uV 11:00:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.471 uVs 11:00:06 I1X Average and RMS of Measurements VT = -91.034 +- 2.464 uVs I1X = 18.207 +- 0.493 uTm 11:00:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:00:13 Integrated Voltage Measurement... 11:00:21 Voltage Offset Correction: v_off_ini = 2841.863 uV, v_off_fin = 2830.377 uV 11:00:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -205.397 uVs 11:00:21 Integrated Voltage Measurement... 11:00:30 Voltage Offset Correction: v_off_ini = 2813.582 uV, v_off_fin = 2817.466 uV 11:00:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.327 uVs 11:00:30 Integrated Voltage Measurement... 11:00:39 Voltage Offset Correction: v_off_ini = 2854.661 uV, v_off_fin = 2826.447 uV 11:00:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.092 uVs 11:00:39 Integrated Voltage Measurement... 11:00:48 Voltage Offset Correction: v_off_ini = 2832.078 uV, v_off_fin = 2848.090 uV 11:00:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.847 uVs 11:00:48 Integrated Voltage Measurement... 11:00:57 Voltage Offset Correction: v_off_ini = 2860.862 uV, v_off_fin = 2831.954 uV 11:00:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.751 uVs 11:00:57 Integrated Voltage Measurement... 11:01:06 Voltage Offset Correction: v_off_ini = 2845.360 uV, v_off_fin = 2864.618 uV 11:01:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.449 uVs 11:01:11 I1Y Average and RMS of Measurements VT = -211.811 +- 1.084 uVs I1Y = -42.363 +- 0.216 uTm 11:01:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:18 Integrated Voltage Measurement... 11:01:27 Voltage Offset Correction: v_off_ini = 2851.972 uV, v_off_fin = 2857.009 uV 11:01:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.411 uVs 11:01:27 Integrated Voltage Measurement... 11:01:36 Voltage Offset Correction: v_off_ini = 2855.235 uV, v_off_fin = 2866.454 uV 11:01:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.743 uVs 11:01:36 Integrated Voltage Measurement... 11:01:45 Voltage Offset Correction: v_off_ini = 2861.129 uV, v_off_fin = 2847.406 uV 11:01:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.551 uVs 11:01:45 Integrated Voltage Measurement... 11:01:54 Voltage Offset Correction: v_off_ini = 2841.978 uV, v_off_fin = 2851.133 uV 11:01:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.847 uVs 11:01:54 Integrated Voltage Measurement... 11:02:03 Voltage Offset Correction: v_off_ini = 2864.645 uV, v_off_fin = 2836.759 uV 11:02:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.144 uVs 11:02:03 Integrated Voltage Measurement... 11:02:12 Voltage Offset Correction: v_off_ini = 2838.355 uV, v_off_fin = 2850.547 uV 11:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.300 uVs 11:02:15 I2X Average and RMS of Measurements VT = -72.333 +- 6.117 uVs I2X = 6.655 +- 0.563 uTm^2 11:02:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:23 Integrated Voltage Measurement... 11:02:31 Voltage Offset Correction: v_off_ini = 2847.526 uV, v_off_fin = 2863.009 uV 11:02:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.837 uVs 11:02:32 Integrated Voltage Measurement... 11:02:41 Voltage Offset Correction: v_off_ini = 2838.862 uV, v_off_fin = 2825.496 uV 11:02:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.568 uVs 11:02:41 Integrated Voltage Measurement... 11:02:50 Voltage Offset Correction: v_off_ini = 2812.472 uV, v_off_fin = 2816.368 uV 11:02:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.855 uVs 11:02:50 Integrated Voltage Measurement... 11:02:59 Voltage Offset Correction: v_off_ini = 2841.981 uV, v_off_fin = 2833.604 uV 11:02:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.092 uVs 11:02:59 Integrated Voltage Measurement... 11:03:08 Voltage Offset Correction: v_off_ini = 2836.362 uV, v_off_fin = 2796.681 uV 11:03:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -242.988 uVs 11:03:08 Integrated Voltage Measurement... 11:03:17 Voltage Offset Correction: v_off_ini = 2814.594 uV, v_off_fin = 2823.843 uV 11:03:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 296.226 uVs 11:03:19 I2Y Average and RMS of Measurements VT = -265.761 +- 7.732 uVs I2Y = -24.451 +- 0.712 uTm^2 11:03:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:03:38 Integrated Voltage Measurement... 11:03:47 Voltage Offset Correction: v_off_ini = 2858.263 uV, v_off_fin = 2838.189 uV 11:03:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -110.465 uVs 11:03:47 Integrated Voltage Measurement... 11:03:56 Voltage Offset Correction: v_off_ini = 2835.632 uV, v_off_fin = 2826.825 uV 11:03:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.504 uVs 11:03:56 Integrated Voltage Measurement... 11:04:05 Voltage Offset Correction: v_off_ini = 2811.465 uV, v_off_fin = 2802.012 uV 11:04:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.263 uVs 11:04:05 Integrated Voltage Measurement... 11:04:14 Voltage Offset Correction: v_off_ini = 2806.502 uV, v_off_fin = 2809.944 uV 11:04:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.740 uVs 11:04:14 Integrated Voltage Measurement... 11:04:23 Voltage Offset Correction: v_off_ini = 2793.085 uV, v_off_fin = 2794.150 uV 11:04:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.820 uVs 11:04:23 Integrated Voltage Measurement... 11:04:32 Voltage Offset Correction: v_off_ini = 2773.543 uV, v_off_fin = 2772.219 uV 11:04:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.575 uVs 11:04:36 I1X Average and RMS of Measurements VT = -101.228 +- 11.900 uVs I1X = 20.246 +- 2.380 uTm 11:04:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:04:43 Integrated Voltage Measurement... 11:04:51 Voltage Offset Correction: v_off_ini = 2792.297 uV, v_off_fin = 2770.246 uV 11:04:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.704 uVs 11:04:52 Integrated Voltage Measurement... 11:05:00 Voltage Offset Correction: v_off_ini = 2773.751 uV, v_off_fin = 2780.395 uV 11:05:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.041 uVs 11:05:01 Integrated Voltage Measurement... 11:05:09 Voltage Offset Correction: v_off_ini = 2780.487 uV, v_off_fin = 2789.590 uV 11:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.819 uVs 11:05:10 Integrated Voltage Measurement... 11:05:18 Voltage Offset Correction: v_off_ini = 2787.181 uV, v_off_fin = 2804.408 uV 11:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 222.160 uVs 11:05:19 Integrated Voltage Measurement... 11:05:27 Voltage Offset Correction: v_off_ini = 2789.076 uV, v_off_fin = 2780.736 uV 11:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.203 uVs 11:05:28 Integrated Voltage Measurement... 11:05:36 Voltage Offset Correction: v_off_ini = 2794.469 uV, v_off_fin = 2791.050 uV 11:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.122 uVs 11:05:41 I1Y Average and RMS of Measurements VT = -214.841 +- 1.821 uVs I1Y = -42.968 +- 0.365 uTm 11:05:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:48 Integrated Voltage Measurement... 11:05:57 Voltage Offset Correction: v_off_ini = 2786.398 uV, v_off_fin = 2777.920 uV 11:05:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.674 uVs 11:05:57 Integrated Voltage Measurement... 11:06:06 Voltage Offset Correction: v_off_ini = 2809.711 uV, v_off_fin = 2794.874 uV 11:06:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.214 uVs 11:06:06 Integrated Voltage Measurement... 11:06:15 Voltage Offset Correction: v_off_ini = 2809.428 uV, v_off_fin = 2795.658 uV 11:06:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.083 uVs 11:06:15 Integrated Voltage Measurement... 11:06:24 Voltage Offset Correction: v_off_ini = 2798.745 uV, v_off_fin = 2806.228 uV 11:06:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.980 uVs 11:06:25 Integrated Voltage Measurement... 11:06:33 Voltage Offset Correction: v_off_ini = 2785.905 uV, v_off_fin = 2795.526 uV 11:06:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.649 uVs 11:06:34 Integrated Voltage Measurement... 11:06:42 Voltage Offset Correction: v_off_ini = 2808.685 uV, v_off_fin = 2816.517 uV 11:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.370 uVs 11:06:45 I2X Average and RMS of Measurements VT = -72.662 +- 12.714 uVs I2X = 6.685 +- 1.170 uTm^2 11:06:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:53 Integrated Voltage Measurement... 11:07:02 Voltage Offset Correction: v_off_ini = 2806.291 uV, v_off_fin = 2786.668 uV 11:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.583 uVs 11:07:02 Integrated Voltage Measurement... 11:07:11 Voltage Offset Correction: v_off_ini = 2763.547 uV, v_off_fin = 2784.467 uV 11:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.505 uVs 11:07:11 Integrated Voltage Measurement... 11:07:20 Voltage Offset Correction: v_off_ini = 2789.526 uV, v_off_fin = 2757.751 uV 11:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.458 uVs 11:07:20 Integrated Voltage Measurement... 11:07:29 Voltage Offset Correction: v_off_ini = 2778.870 uV, v_off_fin = 2788.746 uV 11:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.135 uVs 11:07:29 Integrated Voltage Measurement... 11:07:38 Voltage Offset Correction: v_off_ini = 2770.228 uV, v_off_fin = 2788.363 uV 11:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.094 uVs 11:07:38 Integrated Voltage Measurement... 11:07:47 Voltage Offset Correction: v_off_ini = 2761.020 uV, v_off_fin = 2760.487 uV 11:07:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 285.106 uVs 11:07:49 I2Y Average and RMS of Measurements VT = -260.980 +- 9.824 uVs I2Y = -24.011 +- 0.904 uTm^2 11:07:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm