SLAC Magnetic Measurements Date: 07-24-2026 Time: 11:10:32 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16336 Dataset Number: 1 Run Purpose: Final Results Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 11:10:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:10:42 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:10:43 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:10:45 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:10:46 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:11:25 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:11:29 Integrated Voltage Measurement... 11:11:38 Voltage Offset Correction: v_off_ini = 2840.526 uV, v_off_fin = 2851.682 uV 11:11:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.968 uVs 11:11:38 Integrated Voltage Measurement... 11:11:47 Voltage Offset Correction: v_off_ini = 2821.979 uV, v_off_fin = 2844.242 uV 11:11:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.035 uVs 11:11:47 Integrated Voltage Measurement... 11:11:56 Voltage Offset Correction: v_off_ini = 2814.388 uV, v_off_fin = 2791.452 uV 11:11:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.438 uVs 11:11:56 Integrated Voltage Measurement... 11:12:05 Voltage Offset Correction: v_off_ini = 2828.525 uV, v_off_fin = 2811.904 uV 11:12:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.181 uVs 11:12:05 Integrated Voltage Measurement... 11:12:14 Voltage Offset Correction: v_off_ini = 2810.349 uV, v_off_fin = 2844.854 uV 11:12:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.246 uVs 11:12:14 Integrated Voltage Measurement... 11:12:23 Voltage Offset Correction: v_off_ini = 2841.468 uV, v_off_fin = 2868.376 uV 11:12:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.851 uVs 11:12:27 I1X Average and RMS of Measurements VT = -97.786 +- 18.938 uVs I1X = 19.558 +- 3.787 uTm 11:12:30 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:12:34 Integrated Voltage Measurement... 11:12:43 Voltage Offset Correction: v_off_ini = 2831.702 uV, v_off_fin = 2827.501 uV 11:12:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.510 uVs 11:12:43 Integrated Voltage Measurement... 11:12:52 Voltage Offset Correction: v_off_ini = 2801.482 uV, v_off_fin = 2867.299 uV 11:12:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.987 uVs 11:12:52 Integrated Voltage Measurement... 11:13:01 Voltage Offset Correction: v_off_ini = 2815.555 uV, v_off_fin = 2796.613 uV 11:13:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.340 uVs 11:13:01 Integrated Voltage Measurement... 11:13:10 Voltage Offset Correction: v_off_ini = 2816.395 uV, v_off_fin = 2806.972 uV 11:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.902 uVs 11:13:10 Integrated Voltage Measurement... 11:13:19 Voltage Offset Correction: v_off_ini = 2791.113 uV, v_off_fin = 2782.076 uV 11:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.209 uVs 11:13:19 Integrated Voltage Measurement... 11:13:28 Voltage Offset Correction: v_off_ini = 2790.095 uV, v_off_fin = 2808.438 uV 11:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.206 uVs 11:13:32 I1Y Average and RMS of Measurements VT = -237.026 +- 4.664 uVs I1Y = -47.405 +- 0.933 uTm 11:13:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:13:40 Integrated Voltage Measurement... 11:13:49 Voltage Offset Correction: v_off_ini = 2750.645 uV, v_off_fin = 2758.167 uV 11:13:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.186 uVs 11:13:49 Integrated Voltage Measurement... 11:13:58 Voltage Offset Correction: v_off_ini = 2791.785 uV, v_off_fin = 2801.202 uV 11:13:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.163 uVs 11:13:58 Integrated Voltage Measurement... 11:14:07 Voltage Offset Correction: v_off_ini = 2785.238 uV, v_off_fin = 2776.743 uV 11:14:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.402 uVs 11:14:07 Integrated Voltage Measurement... 11:14:16 Voltage Offset Correction: v_off_ini = 2810.902 uV, v_off_fin = 2790.675 uV 11:14:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.262 uVs 11:14:16 Integrated Voltage Measurement... 11:14:25 Voltage Offset Correction: v_off_ini = 2796.613 uV, v_off_fin = 2808.082 uV 11:14:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.110 uVs 11:14:25 Integrated Voltage Measurement... 11:14:34 Voltage Offset Correction: v_off_ini = 2819.049 uV, v_off_fin = 2808.446 uV 11:14:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.233 uVs 11:14:36 I2X Average and RMS of Measurements VT = -115.393 +- 7.915 uVs I2X = 10.616 +- 0.728 uTm^2 11:14:41 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:14:44 Integrated Voltage Measurement... 11:14:53 Voltage Offset Correction: v_off_ini = 2798.154 uV, v_off_fin = 2788.977 uV 11:14:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -367.134 uVs 11:14:53 Integrated Voltage Measurement... 11:15:02 Voltage Offset Correction: v_off_ini = 2792.702 uV, v_off_fin = 2805.421 uV 11:15:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.302 uVs 11:15:02 Integrated Voltage Measurement... 11:15:11 Voltage Offset Correction: v_off_ini = 2796.265 uV, v_off_fin = 2797.088 uV 11:15:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -359.930 uVs 11:15:11 Integrated Voltage Measurement... 11:15:20 Voltage Offset Correction: v_off_ini = 2791.956 uV, v_off_fin = 2791.757 uV 11:15:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.823 uVs 11:15:20 Integrated Voltage Measurement... 11:15:29 Voltage Offset Correction: v_off_ini = 2790.301 uV, v_off_fin = 2790.926 uV 11:15:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -381.618 uVs 11:15:29 Integrated Voltage Measurement... 11:15:38 Voltage Offset Correction: v_off_ini = 2782.015 uV, v_off_fin = 2787.385 uV 11:15:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.516 uVs 11:15:41 I2Y Average and RMS of Measurements VT = -374.054 +- 9.406 uVs I2Y = -34.413 +- 0.865 uTm^2 11:15:45 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:15:49 Integrated Voltage Measurement... 11:15:58 Voltage Offset Correction: v_off_ini = 2802.351 uV, v_off_fin = 2797.255 uV 11:15:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -149.009 uVs 11:15:58 Integrated Voltage Measurement... 11:16:07 Voltage Offset Correction: v_off_ini = 2790.006 uV, v_off_fin = 2792.196 uV 11:16:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.513 uVs 11:16:07 Integrated Voltage Measurement... 11:16:16 Voltage Offset Correction: v_off_ini = 2818.882 uV, v_off_fin = 2813.456 uV 11:16:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.809 uVs 11:16:16 Integrated Voltage Measurement... 11:16:25 Voltage Offset Correction: v_off_ini = 2815.114 uV, v_off_fin = 2820.541 uV 11:16:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.793 uVs 11:16:25 Integrated Voltage Measurement... 11:16:34 Voltage Offset Correction: v_off_ini = 2820.857 uV, v_off_fin = 2806.615 uV 11:16:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.176 uVs 11:16:34 Integrated Voltage Measurement... 11:16:43 Voltage Offset Correction: v_off_ini = 2829.510 uV, v_off_fin = 2812.758 uV 11:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.215 uVs 11:16:48 I1X Average and RMS of Measurements VT = -112.752 +- 12.886 uVs I1X = 22.553 +- 2.579 uTm 11:16:50 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:16:54 Integrated Voltage Measurement... 11:17:03 Voltage Offset Correction: v_off_ini = 2842.856 uV, v_off_fin = 2812.038 uV 11:17:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.449 uVs 11:17:03 Integrated Voltage Measurement... 11:17:12 Voltage Offset Correction: v_off_ini = 2836.513 uV, v_off_fin = 2844.854 uV 11:17:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.471 uVs 11:17:12 Integrated Voltage Measurement... 11:17:21 Voltage Offset Correction: v_off_ini = 2798.401 uV, v_off_fin = 2789.291 uV 11:17:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.621 uVs 11:17:21 Integrated Voltage Measurement... 11:17:30 Voltage Offset Correction: v_off_ini = 2786.454 uV, v_off_fin = 2780.985 uV 11:17:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.156 uVs 11:17:30 Integrated Voltage Measurement... 11:17:39 Voltage Offset Correction: v_off_ini = 2793.692 uV, v_off_fin = 2784.696 uV 11:17:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.441 uVs 11:17:39 Integrated Voltage Measurement... 11:17:48 Voltage Offset Correction: v_off_ini = 2785.758 uV, v_off_fin = 2801.185 uV 11:17:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.625 uVs 11:17:52 I1Y Average and RMS of Measurements VT = -248.461 +- 13.318 uVs I1Y = -49.692 +- 2.664 uTm 11:17:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:18:00 Integrated Voltage Measurement... 11:18:09 Voltage Offset Correction: v_off_ini = 2810.751 uV, v_off_fin = 2811.217 uV 11:18:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.119 uVs 11:18:09 Integrated Voltage Measurement... 11:18:18 Voltage Offset Correction: v_off_ini = 2818.722 uV, v_off_fin = 2815.094 uV 11:18:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.317 uVs 11:18:18 Integrated Voltage Measurement... 11:18:27 Voltage Offset Correction: v_off_ini = 2808.996 uV, v_off_fin = 2798.232 uV 11:18:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.520 uVs 11:18:27 Integrated Voltage Measurement... 11:18:36 Voltage Offset Correction: v_off_ini = 2789.372 uV, v_off_fin = 2804.990 uV 11:18:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.681 uVs 11:18:36 Integrated Voltage Measurement... 11:18:45 Voltage Offset Correction: v_off_ini = 2798.053 uV, v_off_fin = 2801.900 uV 11:18:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.149 uVs 11:18:45 Integrated Voltage Measurement... 11:18:54 Voltage Offset Correction: v_off_ini = 2823.858 uV, v_off_fin = 2816.456 uV 11:18:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.395 uVs 11:18:57 I2X Average and RMS of Measurements VT = -103.363 +- 11.465 uVs I2X = 9.509 +- 1.055 uTm^2 11:19:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:19:04 Integrated Voltage Measurement... 11:19:13 Voltage Offset Correction: v_off_ini = 2831.664 uV, v_off_fin = 2826.501 uV 11:19:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -417.283 uVs 11:19:13 Integrated Voltage Measurement... 11:19:22 Voltage Offset Correction: v_off_ini = 2809.138 uV, v_off_fin = 2835.854 uV 11:19:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.118 uVs 11:19:22 Integrated Voltage Measurement... 11:19:31 Voltage Offset Correction: v_off_ini = 2815.707 uV, v_off_fin = 2814.691 uV 11:19:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.641 uVs 11:19:31 Integrated Voltage Measurement... 11:19:40 Voltage Offset Correction: v_off_ini = 2819.771 uV, v_off_fin = 2815.061 uV 11:19:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 416.581 uVs 11:19:40 Integrated Voltage Measurement... 11:19:49 Voltage Offset Correction: v_off_ini = 2850.205 uV, v_off_fin = 2860.770 uV 11:19:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.980 uVs 11:19:49 Integrated Voltage Measurement... 11:19:58 Voltage Offset Correction: v_off_ini = 2857.073 uV, v_off_fin = 2879.855 uV 11:19:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 400.708 uVs 11:20:01 I2Y Average and RMS of Measurements VT = -401.719 +- 13.357 uVs I2Y = -36.959 +- 1.228 uTm^2 11:20:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:20:10 Integrated Voltage Measurement... 11:20:19 Voltage Offset Correction: v_off_ini = 2808.171 uV, v_off_fin = 2780.793 uV 11:20:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.935 uVs 11:20:19 Integrated Voltage Measurement... 11:20:28 Voltage Offset Correction: v_off_ini = 2801.104 uV, v_off_fin = 2814.773 uV 11:20:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.814 uVs 11:20:28 Integrated Voltage Measurement... 11:20:37 Voltage Offset Correction: v_off_ini = 2781.320 uV, v_off_fin = 2772.765 uV 11:20:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.306 uVs 11:20:37 Integrated Voltage Measurement... 11:20:46 Voltage Offset Correction: v_off_ini = 2783.287 uV, v_off_fin = 2813.016 uV 11:20:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.133 uVs 11:20:46 Integrated Voltage Measurement... 11:20:55 Voltage Offset Correction: v_off_ini = 2800.907 uV, v_off_fin = 2819.015 uV 11:20:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.028 uVs 11:20:55 Integrated Voltage Measurement... 11:21:04 Voltage Offset Correction: v_off_ini = 2818.576 uV, v_off_fin = 2788.574 uV 11:21:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.032 uVs 11:21:08 I1X Average and RMS of Measurements VT = -87.875 +- 1.201 uVs I1X = 17.576 +- 0.239 uTm 11:21:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:21:15 Integrated Voltage Measurement... 11:21:24 Voltage Offset Correction: v_off_ini = 2802.061 uV, v_off_fin = 2789.818 uV 11:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.689 uVs 11:21:24 Integrated Voltage Measurement... 11:21:33 Voltage Offset Correction: v_off_ini = 2793.048 uV, v_off_fin = 2800.072 uV 11:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.721 uVs 11:21:33 Integrated Voltage Measurement... 11:21:42 Voltage Offset Correction: v_off_ini = 2791.399 uV, v_off_fin = 2774.434 uV 11:21:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.499 uVs 11:21:42 Integrated Voltage Measurement... 11:21:51 Voltage Offset Correction: v_off_ini = 2777.791 uV, v_off_fin = 2780.681 uV 11:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.389 uVs 11:21:51 Integrated Voltage Measurement... 11:22:00 Voltage Offset Correction: v_off_ini = 2802.607 uV, v_off_fin = 2814.590 uV 11:22:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.754 uVs 11:22:00 Integrated Voltage Measurement... 11:22:09 Voltage Offset Correction: v_off_ini = 2818.877 uV, v_off_fin = 2829.763 uV 11:22:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.562 uVs 11:22:13 I1Y Average and RMS of Measurements VT = -258.269 +- 2.677 uVs I1Y = -51.654 +- 0.535 uTm 11:22:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:22:20 Integrated Voltage Measurement... 11:22:29 Voltage Offset Correction: v_off_ini = 2799.629 uV, v_off_fin = 2813.576 uV 11:22:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -46.328 uVs 11:22:29 Integrated Voltage Measurement... 11:22:38 Voltage Offset Correction: v_off_ini = 2821.484 uV, v_off_fin = 2822.489 uV 11:22:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.154 uVs 11:22:38 Integrated Voltage Measurement... 11:22:47 Voltage Offset Correction: v_off_ini = 2798.213 uV, v_off_fin = 2808.129 uV 11:22:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -140.106 uVs 11:22:48 Integrated Voltage Measurement... 11:22:56 Voltage Offset Correction: v_off_ini = 2770.250 uV, v_off_fin = 2783.791 uV 11:22:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.860 uVs 11:22:57 Integrated Voltage Measurement... 11:23:06 Voltage Offset Correction: v_off_ini = 2774.781 uV, v_off_fin = 2775.815 uV 11:23:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.773 uVs 11:23:06 Integrated Voltage Measurement... 11:23:15 Voltage Offset Correction: v_off_ini = 2780.772 uV, v_off_fin = 2817.023 uV 11:23:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.483 uVs 11:23:17 I2X Average and RMS of Measurements VT = -78.118 +- 32.562 uVs I2X = 7.187 +- 2.996 uTm^2 11:23:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:25 Integrated Voltage Measurement... 11:23:34 Voltage Offset Correction: v_off_ini = 2794.358 uV, v_off_fin = 2802.363 uV 11:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -385.701 uVs 11:23:34 Integrated Voltage Measurement... 11:23:43 Voltage Offset Correction: v_off_ini = 2788.795 uV, v_off_fin = 2798.234 uV 11:23:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 444.712 uVs 11:23:43 Integrated Voltage Measurement... 11:23:52 Voltage Offset Correction: v_off_ini = 2819.368 uV, v_off_fin = 2802.838 uV 11:23:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.730 uVs 11:23:52 Integrated Voltage Measurement... 11:24:01 Voltage Offset Correction: v_off_ini = 2787.128 uV, v_off_fin = 2791.514 uV 11:24:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 408.870 uVs 11:24:01 Integrated Voltage Measurement... 11:24:10 Voltage Offset Correction: v_off_ini = 2799.032 uV, v_off_fin = 2800.412 uV 11:24:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -415.399 uVs 11:24:10 Integrated Voltage Measurement... 11:24:19 Voltage Offset Correction: v_off_ini = 2777.727 uV, v_off_fin = 2778.290 uV 11:24:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.476 uVs 11:24:21 I2Y Average and RMS of Measurements VT = -409.648 +- 4.661 uVs I2Y = -37.688 +- 0.429 uTm^2 11:24:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:24:30 Integrated Voltage Measurement... 11:24:39 Voltage Offset Correction: v_off_ini = 2790.053 uV, v_off_fin = 2786.129 uV 11:24:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.635 uVs 11:24:39 Integrated Voltage Measurement... 11:24:48 Voltage Offset Correction: v_off_ini = 2829.527 uV, v_off_fin = 2835.335 uV 11:24:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.320 uVs 11:24:48 Integrated Voltage Measurement... 11:24:57 Voltage Offset Correction: v_off_ini = 2817.404 uV, v_off_fin = 2808.001 uV 11:24:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.952 uVs 11:24:57 Integrated Voltage Measurement... 11:25:06 Voltage Offset Correction: v_off_ini = 2821.169 uV, v_off_fin = 2816.237 uV 11:25:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.766 uVs 11:25:06 Integrated Voltage Measurement... 11:25:15 Voltage Offset Correction: v_off_ini = 2834.411 uV, v_off_fin = 2825.441 uV 11:25:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.603 uVs 11:25:15 Integrated Voltage Measurement... 11:25:24 Voltage Offset Correction: v_off_ini = 2831.412 uV, v_off_fin = 2826.612 uV 11:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.270 uVs 11:25:28 I1X Average and RMS of Measurements VT = -76.424 +- 11.202 uVs I1X = 15.285 +- 2.240 uTm 11:25:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:25:35 Integrated Voltage Measurement... 11:25:44 Voltage Offset Correction: v_off_ini = 2809.025 uV, v_off_fin = 2794.763 uV 11:25:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.516 uVs 11:25:44 Integrated Voltage Measurement... 11:25:53 Voltage Offset Correction: v_off_ini = 2815.896 uV, v_off_fin = 2821.549 uV 11:25:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.788 uVs 11:25:53 Integrated Voltage Measurement... 11:26:02 Voltage Offset Correction: v_off_ini = 2814.885 uV, v_off_fin = 2785.590 uV 11:26:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.457 uVs 11:26:02 Integrated Voltage Measurement... 11:26:11 Voltage Offset Correction: v_off_ini = 2774.369 uV, v_off_fin = 2796.003 uV 11:26:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.505 uVs 11:26:11 Integrated Voltage Measurement... 11:26:20 Voltage Offset Correction: v_off_ini = 2802.184 uV, v_off_fin = 2812.003 uV 11:26:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.654 uVs 11:26:20 Integrated Voltage Measurement... 11:26:29 Voltage Offset Correction: v_off_ini = 2804.745 uV, v_off_fin = 2803.627 uV 11:26:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.599 uVs 11:26:33 I1Y Average and RMS of Measurements VT = -254.920 +- 4.834 uVs I1Y = -50.984 +- 0.967 uTm 11:26:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:26:41 Integrated Voltage Measurement... 11:26:50 Voltage Offset Correction: v_off_ini = 2791.691 uV, v_off_fin = 2777.365 uV 11:26:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.153 uVs 11:26:50 Integrated Voltage Measurement... 11:26:59 Voltage Offset Correction: v_off_ini = 2782.374 uV, v_off_fin = 2809.458 uV 11:26:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.106 uVs 11:26:59 Integrated Voltage Measurement... 11:27:08 Voltage Offset Correction: v_off_ini = 2799.763 uV, v_off_fin = 2790.680 uV 11:27:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.174 uVs 11:27:08 Integrated Voltage Measurement... 11:27:17 Voltage Offset Correction: v_off_ini = 2791.910 uV, v_off_fin = 2803.823 uV 11:27:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.818 uVs 11:27:17 Integrated Voltage Measurement... 11:27:26 Voltage Offset Correction: v_off_ini = 2837.254 uV, v_off_fin = 2812.791 uV 11:27:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -78.701 uVs 11:27:26 Integrated Voltage Measurement... 11:27:35 Voltage Offset Correction: v_off_ini = 2838.815 uV, v_off_fin = 2813.760 uV 11:27:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.769 uVs 11:27:37 I2X Average and RMS of Measurements VT = -60.620 +- 12.049 uVs I2X = 5.577 +- 1.108 uTm^2 11:27:42 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:27:45 Integrated Voltage Measurement... 11:27:54 Voltage Offset Correction: v_off_ini = 2833.286 uV, v_off_fin = 2789.494 uV 11:27:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -425.078 uVs 11:27:54 Integrated Voltage Measurement... 11:28:03 Voltage Offset Correction: v_off_ini = 2797.741 uV, v_off_fin = 2796.281 uV 11:28:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 436.256 uVs 11:28:03 Integrated Voltage Measurement... 11:28:12 Voltage Offset Correction: v_off_ini = 2774.575 uV, v_off_fin = 2800.144 uV 11:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.316 uVs 11:28:12 Integrated Voltage Measurement... 11:28:21 Voltage Offset Correction: v_off_ini = 2796.012 uV, v_off_fin = 2787.633 uV 11:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.879 uVs 11:28:21 Integrated Voltage Measurement... 11:28:30 Voltage Offset Correction: v_off_ini = 2787.815 uV, v_off_fin = 2793.168 uV 11:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -402.621 uVs 11:28:30 Integrated Voltage Measurement... 11:28:39 Voltage Offset Correction: v_off_ini = 2775.239 uV, v_off_fin = 2773.753 uV 11:28:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 417.256 uVs 11:28:42 I2Y Average and RMS of Measurements VT = -411.234 +- 15.365 uVs I2Y = -37.834 +- 1.414 uTm^2 11:28:46 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:28:50 Integrated Voltage Measurement... 11:28:59 Voltage Offset Correction: v_off_ini = 2742.185 uV, v_off_fin = 2753.222 uV 11:28:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.908 uVs 11:28:59 Integrated Voltage Measurement... 11:29:08 Voltage Offset Correction: v_off_ini = 2755.140 uV, v_off_fin = 2762.194 uV 11:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 17.620 uVs 11:29:08 Integrated Voltage Measurement... 11:29:17 Voltage Offset Correction: v_off_ini = 2769.696 uV, v_off_fin = 2750.759 uV 11:29:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.740 uVs 11:29:17 Integrated Voltage Measurement... 11:29:26 Voltage Offset Correction: v_off_ini = 2754.835 uV, v_off_fin = 2738.864 uV 11:29:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.683 uVs 11:29:26 Integrated Voltage Measurement... 11:29:35 Voltage Offset Correction: v_off_ini = 2760.325 uV, v_off_fin = 2750.719 uV 11:29:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 3.165 uVs 11:29:35 Integrated Voltage Measurement... 11:29:44 Voltage Offset Correction: v_off_ini = 2794.338 uV, v_off_fin = 2791.064 uV 11:29:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.075 uVs 11:29:49 I1X Average and RMS of Measurements VT = -32.477 +- 11.975 uVs I1X = 6.495 +- 2.395 uTm 11:29:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:29:55 Integrated Voltage Measurement... 11:30:04 Voltage Offset Correction: v_off_ini = 2742.792 uV, v_off_fin = 2735.279 uV 11:30:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.748 uVs 11:30:04 Integrated Voltage Measurement... 11:30:13 Voltage Offset Correction: v_off_ini = 2742.159 uV, v_off_fin = 2785.950 uV 11:30:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.946 uVs 11:30:13 Integrated Voltage Measurement... 11:30:22 Voltage Offset Correction: v_off_ini = 2789.411 uV, v_off_fin = 2775.821 uV 11:30:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.633 uVs 11:30:22 Integrated Voltage Measurement... 11:30:31 Voltage Offset Correction: v_off_ini = 2746.737 uV, v_off_fin = 2767.598 uV 11:30:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.493 uVs 11:30:31 Integrated Voltage Measurement... 11:30:40 Voltage Offset Correction: v_off_ini = 2765.891 uV, v_off_fin = 2766.447 uV 11:30:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.521 uVs 11:30:40 Integrated Voltage Measurement... 11:30:49 Voltage Offset Correction: v_off_ini = 2791.764 uV, v_off_fin = 2803.352 uV 11:30:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 239.710 uVs 11:30:54 I1Y Average and RMS of Measurements VT = -269.008 +- 10.649 uVs I1Y = -53.802 +- 2.129 uTm 11:30:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:31:01 Integrated Voltage Measurement... 11:31:10 Voltage Offset Correction: v_off_ini = 2780.682 uV, v_off_fin = 2771.524 uV 11:31:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.294 uVs 11:31:10 Integrated Voltage Measurement... 11:31:19 Voltage Offset Correction: v_off_ini = 2767.088 uV, v_off_fin = 2790.310 uV 11:31:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.050 uVs 11:31:19 Integrated Voltage Measurement... 11:31:28 Voltage Offset Correction: v_off_ini = 2781.246 uV, v_off_fin = 2762.871 uV 11:31:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.984 uVs 11:31:28 Integrated Voltage Measurement... 11:31:37 Voltage Offset Correction: v_off_ini = 2770.973 uV, v_off_fin = 2791.455 uV 11:31:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.104 uVs 11:31:37 Integrated Voltage Measurement... 11:31:46 Voltage Offset Correction: v_off_ini = 2768.211 uV, v_off_fin = 2744.664 uV 11:31:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.859 uVs 11:31:46 Integrated Voltage Measurement... 11:31:55 Voltage Offset Correction: v_off_ini = 2751.413 uV, v_off_fin = 2779.284 uV 11:31:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.104 uVs 11:31:58 I2X Average and RMS of Measurements VT = -41.899 +- 6.366 uVs I2X = 3.855 +- 0.586 uTm^2 11:32:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:32:05 Integrated Voltage Measurement... 11:32:14 Voltage Offset Correction: v_off_ini = 2734.217 uV, v_off_fin = 2730.738 uV 11:32:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -436.214 uVs 11:32:14 Integrated Voltage Measurement... 11:32:23 Voltage Offset Correction: v_off_ini = 2732.654 uV, v_off_fin = 2727.880 uV 11:32:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 412.687 uVs 11:32:23 Integrated Voltage Measurement... 11:32:32 Voltage Offset Correction: v_off_ini = 2729.562 uV, v_off_fin = 2709.065 uV 11:32:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.946 uVs 11:32:32 Integrated Voltage Measurement... 11:32:41 Voltage Offset Correction: v_off_ini = 2727.611 uV, v_off_fin = 2734.794 uV 11:32:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 439.578 uVs 11:32:42 Integrated Voltage Measurement... 11:32:50 Voltage Offset Correction: v_off_ini = 2750.918 uV, v_off_fin = 2723.794 uV 11:32:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -456.851 uVs 11:32:51 Integrated Voltage Measurement... 11:33:00 Voltage Offset Correction: v_off_ini = 2723.662 uV, v_off_fin = 2741.395 uV 11:33:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 397.234 uVs 11:33:02 I2Y Average and RMS of Measurements VT = -427.085 +- 2.169 uVs I2Y = -39.292 +- 0.200 uTm^2 11:33:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:33:14 Integrated Voltage Measurement... 11:33:23 Voltage Offset Correction: v_off_ini = 2735.104 uV, v_off_fin = 2723.240 uV 11:33:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.074 uVs 11:33:23 Integrated Voltage Measurement... 11:33:32 Voltage Offset Correction: v_off_ini = 2729.381 uV, v_off_fin = 2711.054 uV 11:33:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.990 uVs 11:33:32 Integrated Voltage Measurement... 11:33:41 Voltage Offset Correction: v_off_ini = 2698.502 uV, v_off_fin = 2674.744 uV 11:33:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.816 uVs 11:33:41 Integrated Voltage Measurement... 11:33:50 Voltage Offset Correction: v_off_ini = 2720.905 uV, v_off_fin = 2705.130 uV 11:33:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.940 uVs 11:33:50 Integrated Voltage Measurement... 11:33:59 Voltage Offset Correction: v_off_ini = 2690.506 uV, v_off_fin = 2681.011 uV 11:33:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -93.920 uVs 11:33:59 Integrated Voltage Measurement... 11:34:08 Voltage Offset Correction: v_off_ini = 2675.502 uV, v_off_fin = 2683.554 uV 11:34:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 64.518 uVs 11:34:12 I1X Average and RMS of Measurements VT = -85.876 +- 6.693 uVs I1X = 17.176 +- 1.338 uTm 11:34:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:34:19 Integrated Voltage Measurement... 11:34:28 Voltage Offset Correction: v_off_ini = 2717.626 uV, v_off_fin = 2696.708 uV 11:34:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -271.213 uVs 11:34:28 Integrated Voltage Measurement... 11:34:37 Voltage Offset Correction: v_off_ini = 2721.934 uV, v_off_fin = 2745.185 uV 11:34:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.049 uVs 11:34:37 Integrated Voltage Measurement... 11:34:46 Voltage Offset Correction: v_off_ini = 2718.309 uV, v_off_fin = 2727.829 uV 11:34:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.369 uVs 11:34:46 Integrated Voltage Measurement... 11:34:55 Voltage Offset Correction: v_off_ini = 2714.926 uV, v_off_fin = 2722.637 uV 11:34:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.885 uVs 11:34:55 Integrated Voltage Measurement... 11:35:04 Voltage Offset Correction: v_off_ini = 2742.006 uV, v_off_fin = 2713.324 uV 11:35:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.980 uVs 11:35:04 Integrated Voltage Measurement... 11:35:13 Voltage Offset Correction: v_off_ini = 2703.158 uV, v_off_fin = 2723.462 uV 11:35:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.701 uVs 11:35:17 I1Y Average and RMS of Measurements VT = -270.533 +- 1.110 uVs I1Y = -54.108 +- 0.222 uTm 11:35:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:35:22 Integrated Voltage Measurement... 11:35:31 Voltage Offset Correction: v_off_ini = 2726.935 uV, v_off_fin = 2745.126 uV 11:35:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -123.100 uVs 11:35:31 Integrated Voltage Measurement... 11:35:40 Voltage Offset Correction: v_off_ini = 2737.962 uV, v_off_fin = 2734.791 uV 11:35:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.108 uVs 11:35:40 Integrated Voltage Measurement... 11:35:49 Voltage Offset Correction: v_off_ini = 2727.741 uV, v_off_fin = 2718.209 uV 11:35:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.199 uVs 11:35:49 Integrated Voltage Measurement... 11:35:58 Voltage Offset Correction: v_off_ini = 2722.271 uV, v_off_fin = 2730.665 uV 11:35:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.716 uVs 11:35:58 Integrated Voltage Measurement... 11:36:07 Voltage Offset Correction: v_off_ini = 2733.077 uV, v_off_fin = 2719.972 uV 11:36:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.930 uVs 11:36:07 Integrated Voltage Measurement... 11:36:16 Voltage Offset Correction: v_off_ini = 2708.506 uV, v_off_fin = 2746.380 uV 11:36:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.658 uVs 11:36:19 I2X Average and RMS of Measurements VT = -91.619 +- 14.088 uVs I2X = 8.429 +- 1.296 uTm^2 11:36:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:36:24 Integrated Voltage Measurement... 11:36:33 Voltage Offset Correction: v_off_ini = 2672.900 uV, v_off_fin = 2684.735 uV 11:36:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -415.700 uVs 11:36:33 Integrated Voltage Measurement... 11:36:42 Voltage Offset Correction: v_off_ini = 2677.891 uV, v_off_fin = 2673.721 uV 11:36:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 435.734 uVs 11:36:42 Integrated Voltage Measurement... 11:36:51 Voltage Offset Correction: v_off_ini = 2684.992 uV, v_off_fin = 2707.325 uV 11:36:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -430.918 uVs 11:36:51 Integrated Voltage Measurement... 11:37:00 Voltage Offset Correction: v_off_ini = 2724.101 uV, v_off_fin = 2727.808 uV 11:37:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 423.543 uVs 11:37:00 Integrated Voltage Measurement... 11:37:09 Voltage Offset Correction: v_off_ini = 2696.487 uV, v_off_fin = 2704.152 uV 11:37:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -422.205 uVs 11:37:09 Integrated Voltage Measurement... 11:37:18 Voltage Offset Correction: v_off_ini = 2698.521 uV, v_off_fin = 2675.817 uV 11:37:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.720 uVs 11:37:20 I2Y Average and RMS of Measurements VT = -424.970 +- 2.215 uVs I2Y = -39.097 +- 0.204 uTm^2 11:37:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:37:29 Integrated Voltage Measurement... 11:37:37 Voltage Offset Correction: v_off_ini = 2705.023 uV, v_off_fin = 2701.645 uV 11:37:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -103.602 uVs 11:37:38 Integrated Voltage Measurement... 11:37:47 Voltage Offset Correction: v_off_ini = 2695.489 uV, v_off_fin = 2675.979 uV 11:37:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.548 uVs 11:37:47 Integrated Voltage Measurement... 11:37:56 Voltage Offset Correction: v_off_ini = 2681.738 uV, v_off_fin = 2691.441 uV 11:37:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.912 uVs 11:37:56 Integrated Voltage Measurement... 11:38:05 Voltage Offset Correction: v_off_ini = 2695.905 uV, v_off_fin = 2697.081 uV 11:38:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.329 uVs 11:38:05 Integrated Voltage Measurement... 11:38:14 Voltage Offset Correction: v_off_ini = 2684.659 uV, v_off_fin = 2681.229 uV 11:38:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.565 uVs 11:38:14 Integrated Voltage Measurement... 11:38:23 Voltage Offset Correction: v_off_ini = 2694.089 uV, v_off_fin = 2703.210 uV 11:38:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 85.184 uVs 11:38:27 I1X Average and RMS of Measurements VT = -79.690 +- 11.677 uVs I1X = 15.940 +- 2.337 uTm 11:38:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:38:34 Integrated Voltage Measurement... 11:38:42 Voltage Offset Correction: v_off_ini = 2681.733 uV, v_off_fin = 2682.788 uV 11:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.025 uVs 11:38:43 Integrated Voltage Measurement... 11:38:51 Voltage Offset Correction: v_off_ini = 2704.562 uV, v_off_fin = 2709.928 uV 11:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.336 uVs 11:38:52 Integrated Voltage Measurement... 11:39:00 Voltage Offset Correction: v_off_ini = 2698.247 uV, v_off_fin = 2664.456 uV 11:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -300.666 uVs 11:39:01 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 2679.912 uV, v_off_fin = 2701.838 uV 11:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.523 uVs 11:39:10 Integrated Voltage Measurement... 11:39:18 Voltage Offset Correction: v_off_ini = 2662.885 uV, v_off_fin = 2652.883 uV 11:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.851 uVs 11:39:19 Integrated Voltage Measurement... 11:39:27 Voltage Offset Correction: v_off_ini = 2643.255 uV, v_off_fin = 2639.606 uV 11:39:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.095 uVs 11:39:32 I1Y Average and RMS of Measurements VT = -271.083 +- 10.598 uVs I1Y = -54.217 +- 2.120 uTm 11:39:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:39:37 Integrated Voltage Measurement... 11:39:46 Voltage Offset Correction: v_off_ini = 2663.274 uV, v_off_fin = 2642.835 uV 11:39:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.927 uVs 11:39:46 Integrated Voltage Measurement... 11:39:55 Voltage Offset Correction: v_off_ini = 2641.705 uV, v_off_fin = 2668.957 uV 11:39:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.833 uVs 11:39:55 Integrated Voltage Measurement... 11:40:04 Voltage Offset Correction: v_off_ini = 2664.626 uV, v_off_fin = 2645.697 uV 11:40:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.399 uVs 11:40:04 Integrated Voltage Measurement... 11:40:13 Voltage Offset Correction: v_off_ini = 2636.443 uV, v_off_fin = 2657.132 uV 11:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.516 uVs 11:40:13 Integrated Voltage Measurement... 11:40:22 Voltage Offset Correction: v_off_ini = 2661.440 uV, v_off_fin = 2651.524 uV 11:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.738 uVs 11:40:22 Integrated Voltage Measurement... 11:40:31 Voltage Offset Correction: v_off_ini = 2667.767 uV, v_off_fin = 2689.371 uV 11:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.842 uVs 11:40:33 I2X Average and RMS of Measurements VT = -76.209 +- 8.651 uVs I2X = 7.012 +- 0.796 uTm^2 11:40:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:40:38 Integrated Voltage Measurement... 11:40:47 Voltage Offset Correction: v_off_ini = 2632.001 uV, v_off_fin = 2622.408 uV 11:40:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -406.702 uVs 11:40:47 Integrated Voltage Measurement... 11:40:56 Voltage Offset Correction: v_off_ini = 2637.421 uV, v_off_fin = 2643.755 uV 11:40:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 460.920 uVs 11:40:56 Integrated Voltage Measurement... 11:41:05 Voltage Offset Correction: v_off_ini = 2633.126 uV, v_off_fin = 2635.794 uV 11:41:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -405.949 uVs 11:41:06 Integrated Voltage Measurement... 11:41:15 Voltage Offset Correction: v_off_ini = 2654.899 uV, v_off_fin = 2658.944 uV 11:41:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 421.084 uVs 11:41:15 Integrated Voltage Measurement... 11:41:24 Voltage Offset Correction: v_off_ini = 2672.391 uV, v_off_fin = 2668.235 uV 11:41:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -402.672 uVs 11:41:24 Integrated Voltage Measurement... 11:41:33 Voltage Offset Correction: v_off_ini = 2665.626 uV, v_off_fin = 2678.113 uV 11:41:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 407.204 uVs 11:41:35 I2Y Average and RMS of Measurements VT = -417.422 +- 12.107 uVs I2Y = -38.403 +- 1.114 uTm^2 11:41:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:41:43 Integrated Voltage Measurement... 11:41:52 Voltage Offset Correction: v_off_ini = 2648.917 uV, v_off_fin = 2637.153 uV 11:41:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -75.979 uVs 11:41:52 Integrated Voltage Measurement... 11:42:01 Voltage Offset Correction: v_off_ini = 2648.784 uV, v_off_fin = 2686.133 uV 11:42:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.523 uVs 11:42:01 Integrated Voltage Measurement... 11:42:10 Voltage Offset Correction: v_off_ini = 2659.033 uV, v_off_fin = 2654.413 uV 11:42:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -92.782 uVs 11:42:10 Integrated Voltage Measurement... 11:42:19 Voltage Offset Correction: v_off_ini = 2663.107 uV, v_off_fin = 2675.072 uV 11:42:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.607 uVs 11:42:19 Integrated Voltage Measurement... 11:42:28 Voltage Offset Correction: v_off_ini = 2669.967 uV, v_off_fin = 2687.481 uV 11:42:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.241 uVs 11:42:28 Integrated Voltage Measurement... 11:42:37 Voltage Offset Correction: v_off_ini = 2666.200 uV, v_off_fin = 2671.118 uV 11:42:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.950 uVs 11:42:41 I1X Average and RMS of Measurements VT = -77.514 +- 9.617 uVs I1X = 15.505 +- 1.923 uTm 11:42:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:42:48 Integrated Voltage Measurement... 11:42:57 Voltage Offset Correction: v_off_ini = 2661.215 uV, v_off_fin = 2639.434 uV 11:42:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.454 uVs 11:42:57 Integrated Voltage Measurement... 11:43:06 Voltage Offset Correction: v_off_ini = 2644.496 uV, v_off_fin = 2640.883 uV 11:43:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.802 uVs 11:43:06 Integrated Voltage Measurement... 11:43:15 Voltage Offset Correction: v_off_ini = 2621.084 uV, v_off_fin = 2624.230 uV 11:43:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.686 uVs 11:43:15 Integrated Voltage Measurement... 11:43:24 Voltage Offset Correction: v_off_ini = 2657.226 uV, v_off_fin = 2655.434 uV 11:43:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.939 uVs 11:43:24 Integrated Voltage Measurement... 11:43:33 Voltage Offset Correction: v_off_ini = 2659.730 uV, v_off_fin = 2636.439 uV 11:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.815 uVs 11:43:33 Integrated Voltage Measurement... 11:43:42 Voltage Offset Correction: v_off_ini = 2623.504 uV, v_off_fin = 2654.547 uV 11:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.063 uVs 11:43:46 I1Y Average and RMS of Measurements VT = -256.793 +- 6.740 uVs I1Y = -51.359 +- 1.348 uTm 11:43:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:43:51 Integrated Voltage Measurement... 11:44:00 Voltage Offset Correction: v_off_ini = 2635.341 uV, v_off_fin = 2632.912 uV 11:44:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -88.098 uVs 11:44:00 Integrated Voltage Measurement... 11:44:09 Voltage Offset Correction: v_off_ini = 2635.190 uV, v_off_fin = 2644.060 uV 11:44:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.283 uVs 11:44:09 Integrated Voltage Measurement... 11:44:18 Voltage Offset Correction: v_off_ini = 2626.371 uV, v_off_fin = 2630.105 uV 11:44:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.964 uVs 11:44:19 Integrated Voltage Measurement... 11:44:27 Voltage Offset Correction: v_off_ini = 2639.258 uV, v_off_fin = 2649.414 uV 11:44:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.510 uVs 11:44:28 Integrated Voltage Measurement... 11:44:37 Voltage Offset Correction: v_off_ini = 2646.513 uV, v_off_fin = 2615.210 uV 11:44:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.101 uVs 11:44:37 Integrated Voltage Measurement... 11:44:46 Voltage Offset Correction: v_off_ini = 2635.192 uV, v_off_fin = 2670.558 uV 11:44:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.583 uVs 11:44:48 I2X Average and RMS of Measurements VT = -84.590 +- 8.348 uVs I2X = 7.782 +- 0.768 uTm^2 11:44:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:44:53 Integrated Voltage Measurement... 11:45:02 Voltage Offset Correction: v_off_ini = 2637.528 uV, v_off_fin = 2631.035 uV 11:45:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -413.255 uVs 11:45:02 Integrated Voltage Measurement... 11:45:11 Voltage Offset Correction: v_off_ini = 2668.369 uV, v_off_fin = 2661.160 uV 11:45:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 402.583 uVs 11:45:11 Integrated Voltage Measurement... 11:45:20 Voltage Offset Correction: v_off_ini = 2647.599 uV, v_off_fin = 2673.732 uV 11:45:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.505 uVs 11:45:20 Integrated Voltage Measurement... 11:45:29 Voltage Offset Correction: v_off_ini = 2675.369 uV, v_off_fin = 2643.220 uV 11:45:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 411.661 uVs 11:45:29 Integrated Voltage Measurement... 11:45:38 Voltage Offset Correction: v_off_ini = 2687.110 uV, v_off_fin = 2657.205 uV 11:45:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -416.674 uVs 11:45:38 Integrated Voltage Measurement... 11:45:47 Voltage Offset Correction: v_off_ini = 2662.556 uV, v_off_fin = 2661.959 uV 11:45:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.598 uVs 11:45:50 I2Y Average and RMS of Measurements VT = -404.546 +- 5.285 uVs I2Y = -37.218 +- 0.486 uTm^2 11:45:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:45:58 Integrated Voltage Measurement... 11:46:07 Voltage Offset Correction: v_off_ini = 2660.143 uV, v_off_fin = 2637.994 uV 11:46:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -60.951 uVs 11:46:07 Integrated Voltage Measurement... 11:46:16 Voltage Offset Correction: v_off_ini = 2637.262 uV, v_off_fin = 2638.079 uV 11:46:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 60.948 uVs 11:46:16 Integrated Voltage Measurement... 11:46:25 Voltage Offset Correction: v_off_ini = 2637.612 uV, v_off_fin = 2646.045 uV 11:46:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.586 uVs 11:46:25 Integrated Voltage Measurement... 11:46:34 Voltage Offset Correction: v_off_ini = 2643.593 uV, v_off_fin = 2668.768 uV 11:46:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.105 uVs 11:46:34 Integrated Voltage Measurement... 11:46:43 Voltage Offset Correction: v_off_ini = 2644.620 uV, v_off_fin = 2657.138 uV 11:46:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.230 uVs 11:46:43 Integrated Voltage Measurement... 11:46:52 Voltage Offset Correction: v_off_ini = 2684.618 uV, v_off_fin = 2682.819 uV 11:46:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.244 uVs 11:46:56 I1X Average and RMS of Measurements VT = -65.344 +- 5.259 uVs I1X = 13.070 +- 1.052 uTm 11:46:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:47:03 Integrated Voltage Measurement... 11:47:12 Voltage Offset Correction: v_off_ini = 2666.189 uV, v_off_fin = 2649.713 uV 11:47:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.444 uVs 11:47:12 Integrated Voltage Measurement... 11:47:21 Voltage Offset Correction: v_off_ini = 2652.256 uV, v_off_fin = 2644.975 uV 11:47:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 257.562 uVs 11:47:21 Integrated Voltage Measurement... 11:47:30 Voltage Offset Correction: v_off_ini = 2621.853 uV, v_off_fin = 2623.087 uV 11:47:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.894 uVs 11:47:30 Integrated Voltage Measurement... 11:47:39 Voltage Offset Correction: v_off_ini = 2627.181 uV, v_off_fin = 2659.199 uV 11:47:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 250.724 uVs 11:47:39 Integrated Voltage Measurement... 11:47:48 Voltage Offset Correction: v_off_ini = 2649.775 uV, v_off_fin = 2622.833 uV 11:47:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.350 uVs 11:47:48 Integrated Voltage Measurement... 11:47:57 Voltage Offset Correction: v_off_ini = 2657.835 uV, v_off_fin = 2683.780 uV 11:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.316 uVs 11:48:01 I1Y Average and RMS of Measurements VT = -251.715 +- 9.576 uVs I1Y = -50.342 +- 1.914 uTm 11:48:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:48:06 Integrated Voltage Measurement... 11:48:15 Voltage Offset Correction: v_off_ini = 2666.749 uV, v_off_fin = 2662.727 uV 11:48:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -58.213 uVs 11:48:15 Integrated Voltage Measurement... 11:48:24 Voltage Offset Correction: v_off_ini = 2679.179 uV, v_off_fin = 2662.651 uV 11:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.806 uVs 11:48:24 Integrated Voltage Measurement... 11:48:33 Voltage Offset Correction: v_off_ini = 2676.519 uV, v_off_fin = 2654.027 uV 11:48:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.557 uVs 11:48:33 Integrated Voltage Measurement... 11:48:42 Voltage Offset Correction: v_off_ini = 2645.736 uV, v_off_fin = 2660.242 uV 11:48:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.455 uVs 11:48:42 Integrated Voltage Measurement... 11:48:51 Voltage Offset Correction: v_off_ini = 2640.288 uV, v_off_fin = 2646.568 uV 11:48:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -52.623 uVs 11:48:51 Integrated Voltage Measurement... 11:49:00 Voltage Offset Correction: v_off_ini = 2666.868 uV, v_off_fin = 2678.213 uV 11:49:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.174 uVs 11:49:03 I2X Average and RMS of Measurements VT = -70.638 +- 14.027 uVs I2X = 6.499 +- 1.290 uTm^2 11:49:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:49:08 Integrated Voltage Measurement... 11:49:17 Voltage Offset Correction: v_off_ini = 2652.660 uV, v_off_fin = 2670.923 uV 11:49:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -394.235 uVs 11:49:17 Integrated Voltage Measurement... 11:49:26 Voltage Offset Correction: v_off_ini = 2663.593 uV, v_off_fin = 2662.717 uV 11:49:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 400.035 uVs 11:49:26 Integrated Voltage Measurement... 11:49:35 Voltage Offset Correction: v_off_ini = 2650.274 uV, v_off_fin = 2650.137 uV 11:49:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.458 uVs 11:49:35 Integrated Voltage Measurement... 11:49:44 Voltage Offset Correction: v_off_ini = 2659.857 uV, v_off_fin = 2674.202 uV 11:49:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 388.918 uVs 11:49:44 Integrated Voltage Measurement... 11:49:53 Voltage Offset Correction: v_off_ini = 2639.417 uV, v_off_fin = 2641.934 uV 11:49:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.460 uVs 11:49:53 Integrated Voltage Measurement... 11:50:02 Voltage Offset Correction: v_off_ini = 2645.317 uV, v_off_fin = 2672.919 uV 11:50:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 433.440 uVs 11:50:04 I2Y Average and RMS of Measurements VT = -395.591 +- 11.589 uVs I2Y = -36.395 +- 1.066 uTm^2 11:50:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:50:13 Integrated Voltage Measurement... 11:50:22 Voltage Offset Correction: v_off_ini = 2654.210 uV, v_off_fin = 2634.291 uV 11:50:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.400 uVs 11:50:22 Integrated Voltage Measurement... 11:50:31 Voltage Offset Correction: v_off_ini = 2633.099 uV, v_off_fin = 2656.897 uV 11:50:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.539 uVs 11:50:31 Integrated Voltage Measurement... 11:50:40 Voltage Offset Correction: v_off_ini = 2668.058 uV, v_off_fin = 2663.204 uV 11:50:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.618 uVs 11:50:40 Integrated Voltage Measurement... 11:50:49 Voltage Offset Correction: v_off_ini = 2659.849 uV, v_off_fin = 2652.229 uV 11:50:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.791 uVs 11:50:49 Integrated Voltage Measurement... 11:50:58 Voltage Offset Correction: v_off_ini = 2649.359 uV, v_off_fin = 2644.176 uV 11:50:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.910 uVs 11:50:58 Integrated Voltage Measurement... 11:51:07 Voltage Offset Correction: v_off_ini = 2648.968 uV, v_off_fin = 2638.477 uV 11:51:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.650 uVs 11:51:11 I1X Average and RMS of Measurements VT = -74.485 +- 11.530 uVs I1X = 14.897 +- 2.306 uTm 11:51:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:51:18 Integrated Voltage Measurement... 11:51:27 Voltage Offset Correction: v_off_ini = 2613.520 uV, v_off_fin = 2605.675 uV 11:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.288 uVs 11:51:27 Integrated Voltage Measurement... 11:51:36 Voltage Offset Correction: v_off_ini = 2614.217 uV, v_off_fin = 2639.569 uV 11:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.709 uVs 11:51:36 Integrated Voltage Measurement... 11:51:45 Voltage Offset Correction: v_off_ini = 2632.352 uV, v_off_fin = 2633.321 uV 11:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -234.106 uVs 11:51:45 Integrated Voltage Measurement... 11:51:54 Voltage Offset Correction: v_off_ini = 2637.366 uV, v_off_fin = 2657.089 uV 11:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.416 uVs 11:51:54 Integrated Voltage Measurement... 11:52:03 Voltage Offset Correction: v_off_ini = 2674.959 uV, v_off_fin = 2677.626 uV 11:52:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.730 uVs 11:52:03 Integrated Voltage Measurement... 11:52:12 Voltage Offset Correction: v_off_ini = 2669.623 uV, v_off_fin = 2668.109 uV 11:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.524 uVs 11:52:16 I1Y Average and RMS of Measurements VT = -247.462 +- 9.309 uVs I1Y = -49.491 +- 1.863 uTm 11:52:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:52:21 Integrated Voltage Measurement... 11:52:30 Voltage Offset Correction: v_off_ini = 2644.317 uV, v_off_fin = 2646.327 uV 11:52:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.548 uVs 11:52:30 Integrated Voltage Measurement... 11:52:39 Voltage Offset Correction: v_off_ini = 2644.332 uV, v_off_fin = 2640.039 uV 11:52:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.237 uVs 11:52:39 Integrated Voltage Measurement... 11:52:48 Voltage Offset Correction: v_off_ini = 2625.891 uV, v_off_fin = 2610.662 uV 11:52:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.863 uVs 11:52:48 Integrated Voltage Measurement... 11:52:57 Voltage Offset Correction: v_off_ini = 2605.351 uV, v_off_fin = 2619.472 uV 11:52:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 57.195 uVs 11:52:57 Integrated Voltage Measurement... 11:53:06 Voltage Offset Correction: v_off_ini = 2604.465 uV, v_off_fin = 2611.710 uV 11:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.436 uVs 11:53:06 Integrated Voltage Measurement... 11:53:15 Voltage Offset Correction: v_off_ini = 2650.293 uV, v_off_fin = 2644.650 uV 11:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.324 uVs 11:53:18 I2X Average and RMS of Measurements VT = -54.601 +- 16.890 uVs I2X = 5.023 +- 1.554 uTm^2 11:53:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:53:23 Integrated Voltage Measurement... 11:53:32 Voltage Offset Correction: v_off_ini = 2630.945 uV, v_off_fin = 2634.306 uV 11:53:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.658 uVs 11:53:32 Integrated Voltage Measurement... 11:53:41 Voltage Offset Correction: v_off_ini = 2626.309 uV, v_off_fin = 2619.772 uV 11:53:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 376.385 uVs 11:53:41 Integrated Voltage Measurement... 11:53:50 Voltage Offset Correction: v_off_ini = 2606.481 uV, v_off_fin = 2617.137 uV 11:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.972 uVs 11:53:50 Integrated Voltage Measurement... 11:53:59 Voltage Offset Correction: v_off_ini = 2600.884 uV, v_off_fin = 2592.997 uV 11:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 367.441 uVs 11:53:59 Integrated Voltage Measurement... 11:54:08 Voltage Offset Correction: v_off_ini = 2622.000 uV, v_off_fin = 2615.670 uV 11:54:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -378.425 uVs 11:54:08 Integrated Voltage Measurement... 11:54:17 Voltage Offset Correction: v_off_ini = 2623.971 uV, v_off_fin = 2612.743 uV 11:54:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.212 uVs 11:54:19 I2Y Average and RMS of Measurements VT = -372.349 +- 4.243 uVs I2Y = -34.256 +- 0.390 uTm^2 11:54:35 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:54:39 Integrated Voltage Measurement... 11:54:48 Voltage Offset Correction: v_off_ini = 2632.343 uV, v_off_fin = 2614.530 uV 11:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.815 uVs 11:54:48 Integrated Voltage Measurement... 11:54:57 Voltage Offset Correction: v_off_ini = 2595.759 uV, v_off_fin = 2624.542 uV 11:54:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.446 uVs 11:54:57 Integrated Voltage Measurement... 11:55:06 Voltage Offset Correction: v_off_ini = 2616.114 uV, v_off_fin = 2612.484 uV 11:55:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.448 uVs 11:55:06 Integrated Voltage Measurement... 11:55:15 Voltage Offset Correction: v_off_ini = 2613.124 uV, v_off_fin = 2620.148 uV 11:55:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.788 uVs 11:55:15 Integrated Voltage Measurement... 11:55:24 Voltage Offset Correction: v_off_ini = 2608.949 uV, v_off_fin = 2594.006 uV 11:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.378 uVs 11:55:24 Integrated Voltage Measurement... 11:55:33 Voltage Offset Correction: v_off_ini = 2576.721 uV, v_off_fin = 2556.195 uV 11:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.502 uVs 11:55:38 I1X Average and RMS of Measurements VT = -88.563 +- 3.852 uVs I1X = 17.713 +- 0.770 uTm 11:55:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:55:44 Integrated Voltage Measurement... 11:55:53 Voltage Offset Correction: v_off_ini = 2588.052 uV, v_off_fin = 2583.409 uV 11:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.045 uVs 11:55:53 Integrated Voltage Measurement... 11:56:02 Voltage Offset Correction: v_off_ini = 2582.395 uV, v_off_fin = 2587.073 uV 11:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.440 uVs 11:56:02 Integrated Voltage Measurement... 11:56:11 Voltage Offset Correction: v_off_ini = 2586.356 uV, v_off_fin = 2551.723 uV 11:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.365 uVs 11:56:11 Integrated Voltage Measurement... 11:56:20 Voltage Offset Correction: v_off_ini = 2557.638 uV, v_off_fin = 2576.700 uV 11:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.267 uVs 11:56:20 Integrated Voltage Measurement... 11:56:29 Voltage Offset Correction: v_off_ini = 2553.394 uV, v_off_fin = 2544.506 uV 11:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.078 uVs 11:56:29 Integrated Voltage Measurement... 11:56:38 Voltage Offset Correction: v_off_ini = 2590.259 uV, v_off_fin = 2595.207 uV 11:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.215 uVs 11:56:42 I1Y Average and RMS of Measurements VT = -218.735 +- 6.202 uVs I1Y = -43.747 +- 1.240 uTm 11:56:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:56:50 Integrated Voltage Measurement... 11:56:59 Voltage Offset Correction: v_off_ini = 2575.567 uV, v_off_fin = 2569.482 uV 11:56:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.806 uVs 11:56:59 Integrated Voltage Measurement... 11:57:08 Voltage Offset Correction: v_off_ini = 2572.364 uV, v_off_fin = 2549.309 uV 11:57:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.937 uVs 11:57:08 Integrated Voltage Measurement... 11:57:17 Voltage Offset Correction: v_off_ini = 2542.215 uV, v_off_fin = 2549.242 uV 11:57:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -113.812 uVs 11:57:17 Integrated Voltage Measurement... 11:57:26 Voltage Offset Correction: v_off_ini = 2586.372 uV, v_off_fin = 2566.533 uV 11:57:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.728 uVs 11:57:26 Integrated Voltage Measurement... 11:57:35 Voltage Offset Correction: v_off_ini = 2550.197 uV, v_off_fin = 2556.341 uV 11:57:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.105 uVs 11:57:35 Integrated Voltage Measurement... 11:57:44 Voltage Offset Correction: v_off_ini = 2550.613 uV, v_off_fin = 2568.078 uV 11:57:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.159 uVs 11:57:47 I2X Average and RMS of Measurements VT = -94.425 +- 7.893 uVs I2X = 8.688 +- 0.726 uTm^2 11:57:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:57:54 Integrated Voltage Measurement... 11:58:03 Voltage Offset Correction: v_off_ini = 2571.623 uV, v_off_fin = 2578.611 uV 11:58:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.178 uVs 11:58:03 Integrated Voltage Measurement... 11:58:12 Voltage Offset Correction: v_off_ini = 2561.031 uV, v_off_fin = 2557.859 uV 11:58:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.813 uVs 11:58:12 Integrated Voltage Measurement... 11:58:21 Voltage Offset Correction: v_off_ini = 2560.109 uV, v_off_fin = 2561.828 uV 11:58:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -385.896 uVs 11:58:21 Integrated Voltage Measurement... 11:58:30 Voltage Offset Correction: v_off_ini = 2568.075 uV, v_off_fin = 2588.231 uV 11:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.422 uVs 11:58:31 Integrated Voltage Measurement... 11:58:40 Voltage Offset Correction: v_off_ini = 2583.411 uV, v_off_fin = 2560.259 uV 11:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.984 uVs 11:58:40 Integrated Voltage Measurement... 11:58:49 Voltage Offset Correction: v_off_ini = 2592.154 uV, v_off_fin = 2570.480 uV 11:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.646 uVs 11:58:51 I2Y Average and RMS of Measurements VT = -365.490 +- 11.253 uVs I2Y = -33.625 +- 1.035 uTm^2 11:58:56 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:59:00 Integrated Voltage Measurement... 11:59:09 Voltage Offset Correction: v_off_ini = 2555.952 uV, v_off_fin = 2533.422 uV 11:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -65.165 uVs 11:59:09 Integrated Voltage Measurement... 11:59:18 Voltage Offset Correction: v_off_ini = 2577.407 uV, v_off_fin = 2575.011 uV 11:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.934 uVs 11:59:18 Integrated Voltage Measurement... 11:59:27 Voltage Offset Correction: v_off_ini = 2566.842 uV, v_off_fin = 2561.273 uV 11:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.721 uVs 11:59:27 Integrated Voltage Measurement... 11:59:36 Voltage Offset Correction: v_off_ini = 2566.684 uV, v_off_fin = 2586.695 uV 11:59:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.711 uVs 11:59:36 Integrated Voltage Measurement... 11:59:45 Voltage Offset Correction: v_off_ini = 2584.785 uV, v_off_fin = 2557.816 uV 11:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.526 uVs 11:59:45 Integrated Voltage Measurement... 11:59:54 Voltage Offset Correction: v_off_ini = 2571.753 uV, v_off_fin = 2557.218 uV 11:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.045 uVs 11:59:58 I1X Average and RMS of Measurements VT = -76.184 +- 2.578 uVs I1X = 15.237 +- 0.516 uTm 12:00:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:00:05 Integrated Voltage Measurement... 12:00:14 Voltage Offset Correction: v_off_ini = 2586.730 uV, v_off_fin = 2559.291 uV 12:00:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.712 uVs 12:00:14 Integrated Voltage Measurement... 12:00:23 Voltage Offset Correction: v_off_ini = 2577.118 uV, v_off_fin = 2590.087 uV 12:00:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.736 uVs 12:00:23 Integrated Voltage Measurement... 12:00:32 Voltage Offset Correction: v_off_ini = 2576.065 uV, v_off_fin = 2564.529 uV 12:00:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.111 uVs 12:00:32 Integrated Voltage Measurement... 12:00:41 Voltage Offset Correction: v_off_ini = 2578.105 uV, v_off_fin = 2587.593 uV 12:00:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.633 uVs 12:00:41 Integrated Voltage Measurement... 12:00:50 Voltage Offset Correction: v_off_ini = 2586.138 uV, v_off_fin = 2578.752 uV 12:00:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.233 uVs 12:00:50 Integrated Voltage Measurement... 12:00:59 Voltage Offset Correction: v_off_ini = 2584.454 uV, v_off_fin = 2580.234 uV 12:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.537 uVs 12:01:03 I1Y Average and RMS of Measurements VT = -231.160 +- 3.211 uVs I1Y = -46.232 +- 0.642 uTm 12:01:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:01:11 Integrated Voltage Measurement... 12:01:20 Voltage Offset Correction: v_off_ini = 2575.378 uV, v_off_fin = 2584.509 uV 12:01:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.568 uVs 12:01:20 Integrated Voltage Measurement... 12:01:29 Voltage Offset Correction: v_off_ini = 2555.450 uV, v_off_fin = 2559.571 uV 12:01:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.312 uVs 12:01:29 Integrated Voltage Measurement... 12:01:38 Voltage Offset Correction: v_off_ini = 2575.082 uV, v_off_fin = 2570.374 uV 12:01:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.738 uVs 12:01:38 Integrated Voltage Measurement... 12:01:47 Voltage Offset Correction: v_off_ini = 2564.428 uV, v_off_fin = 2578.204 uV 12:01:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.732 uVs 12:01:47 Integrated Voltage Measurement... 12:01:56 Voltage Offset Correction: v_off_ini = 2576.539 uV, v_off_fin = 2554.465 uV 12:01:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.745 uVs 12:01:56 Integrated Voltage Measurement... 12:02:05 Voltage Offset Correction: v_off_ini = 2554.965 uV, v_off_fin = 2566.830 uV 12:02:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.584 uVs 12:02:07 I2X Average and RMS of Measurements VT = -88.946 +- 4.317 uVs I2X = 8.183 +- 0.397 uTm^2 12:02:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:02:15 Integrated Voltage Measurement... 12:02:24 Voltage Offset Correction: v_off_ini = 2576.860 uV, v_off_fin = 2551.568 uV 12:02:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.664 uVs 12:02:24 Integrated Voltage Measurement... 12:02:33 Voltage Offset Correction: v_off_ini = 2570.804 uV, v_off_fin = 2565.434 uV 12:02:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 395.599 uVs 12:02:33 Integrated Voltage Measurement... 12:02:42 Voltage Offset Correction: v_off_ini = 2570.396 uV, v_off_fin = 2566.504 uV 12:02:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -366.162 uVs 12:02:42 Integrated Voltage Measurement... 12:02:51 Voltage Offset Correction: v_off_ini = 2563.169 uV, v_off_fin = 2561.573 uV 12:02:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 394.950 uVs 12:02:51 Integrated Voltage Measurement... 12:03:00 Voltage Offset Correction: v_off_ini = 2575.904 uV, v_off_fin = 2569.528 uV 12:03:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.145 uVs 12:03:00 Integrated Voltage Measurement... 12:03:09 Voltage Offset Correction: v_off_ini = 2579.230 uV, v_off_fin = 2591.053 uV 12:03:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.037 uVs 12:03:11 I2Y Average and RMS of Measurements VT = -378.259 +- 1.670 uVs I2Y = -34.800 +- 0.154 uTm^2 12:03:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:20 Integrated Voltage Measurement... 12:03:29 Voltage Offset Correction: v_off_ini = 2586.845 uV, v_off_fin = 2588.865 uV 12:03:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.289 uVs 12:03:29 Integrated Voltage Measurement... 12:03:38 Voltage Offset Correction: v_off_ini = 2563.120 uV, v_off_fin = 2582.383 uV 12:03:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.375 uVs 12:03:38 Integrated Voltage Measurement... 12:03:47 Voltage Offset Correction: v_off_ini = 2581.249 uV, v_off_fin = 2567.114 uV 12:03:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.386 uVs 12:03:47 Integrated Voltage Measurement... 12:03:56 Voltage Offset Correction: v_off_ini = 2574.943 uV, v_off_fin = 2565.862 uV 12:03:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.392 uVs 12:03:56 Integrated Voltage Measurement... 12:04:05 Voltage Offset Correction: v_off_ini = 2565.000 uV, v_off_fin = 2560.337 uV 12:04:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.636 uVs 12:04:05 Integrated Voltage Measurement... 12:04:14 Voltage Offset Correction: v_off_ini = 2568.987 uV, v_off_fin = 2580.003 uV 12:04:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 30.232 uVs 12:04:19 I1X Average and RMS of Measurements VT = -72.885 +- 7.041 uVs I1X = 14.578 +- 1.408 uTm 12:04:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:25 Integrated Voltage Measurement... 12:04:34 Voltage Offset Correction: v_off_ini = 2579.367 uV, v_off_fin = 2564.276 uV 12:04:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.682 uVs 12:04:34 Integrated Voltage Measurement... 12:04:43 Voltage Offset Correction: v_off_ini = 2558.953 uV, v_off_fin = 2579.665 uV 12:04:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.047 uVs 12:04:43 Integrated Voltage Measurement... 12:04:52 Voltage Offset Correction: v_off_ini = 2547.142 uV, v_off_fin = 2582.506 uV 12:04:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.536 uVs 12:04:52 Integrated Voltage Measurement... 12:05:01 Voltage Offset Correction: v_off_ini = 2568.335 uV, v_off_fin = 2590.080 uV 12:05:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.159 uVs 12:05:01 Integrated Voltage Measurement... 12:05:10 Voltage Offset Correction: v_off_ini = 2570.940 uV, v_off_fin = 2576.747 uV 12:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.211 uVs 12:05:10 Integrated Voltage Measurement... 12:05:19 Voltage Offset Correction: v_off_ini = 2571.968 uV, v_off_fin = 2592.509 uV 12:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.718 uVs 12:05:23 I1Y Average and RMS of Measurements VT = -243.225 +- 14.096 uVs I1Y = -48.645 +- 2.819 uTm 12:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:31 Integrated Voltage Measurement... 12:05:40 Voltage Offset Correction: v_off_ini = 2633.691 uV, v_off_fin = 2581.951 uV 12:05:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.454 uVs 12:05:40 Integrated Voltage Measurement... 12:05:49 Voltage Offset Correction: v_off_ini = 2604.565 uV, v_off_fin = 2611.642 uV 12:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.058 uVs 12:05:49 Integrated Voltage Measurement... 12:05:58 Voltage Offset Correction: v_off_ini = 2620.142 uV, v_off_fin = 2605.461 uV 12:05:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.244 uVs 12:05:58 Integrated Voltage Measurement... 12:06:07 Voltage Offset Correction: v_off_ini = 2621.261 uV, v_off_fin = 2606.575 uV 12:06:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.155 uVs 12:06:07 Integrated Voltage Measurement... 12:06:16 Voltage Offset Correction: v_off_ini = 2594.857 uV, v_off_fin = 2597.510 uV 12:06:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.457 uVs 12:06:16 Integrated Voltage Measurement... 12:06:25 Voltage Offset Correction: v_off_ini = 2608.014 uV, v_off_fin = 2611.498 uV 12:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.292 uVs 12:06:28 I2X Average and RMS of Measurements VT = -86.443 +- 10.454 uVs I2X = 7.953 +- 0.962 uTm^2 12:06:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:35 Integrated Voltage Measurement... 12:06:44 Voltage Offset Correction: v_off_ini = 2615.998 uV, v_off_fin = 2582.291 uV 12:06:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.606 uVs 12:06:44 Integrated Voltage Measurement... 12:06:53 Voltage Offset Correction: v_off_ini = 2616.303 uV, v_off_fin = 2598.335 uV 12:06:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 379.542 uVs 12:06:53 Integrated Voltage Measurement... 12:07:02 Voltage Offset Correction: v_off_ini = 2612.480 uV, v_off_fin = 2626.106 uV 12:07:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -382.198 uVs 12:07:02 Integrated Voltage Measurement... 12:07:11 Voltage Offset Correction: v_off_ini = 2623.928 uV, v_off_fin = 2632.828 uV 12:07:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.812 uVs 12:07:11 Integrated Voltage Measurement... 12:07:20 Voltage Offset Correction: v_off_ini = 2617.549 uV, v_off_fin = 2625.734 uV 12:07:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.115 uVs 12:07:20 Integrated Voltage Measurement... 12:07:29 Voltage Offset Correction: v_off_ini = 2643.124 uV, v_off_fin = 2624.725 uV 12:07:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.267 uVs 12:07:32 I2Y Average and RMS of Measurements VT = -368.423 +- 14.748 uVs I2Y = -33.895 +- 1.357 uTm^2 12:07:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:07:41 Integrated Voltage Measurement... 12:07:50 Voltage Offset Correction: v_off_ini = 2597.854 uV, v_off_fin = 2597.917 uV 12:07:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.074 uVs 12:07:50 Integrated Voltage Measurement... 12:07:59 Voltage Offset Correction: v_off_ini = 2608.738 uV, v_off_fin = 2597.260 uV 12:07:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.719 uVs 12:07:59 Integrated Voltage Measurement... 12:08:08 Voltage Offset Correction: v_off_ini = 2613.052 uV, v_off_fin = 2584.104 uV 12:08:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.108 uVs 12:08:08 Integrated Voltage Measurement... 12:08:17 Voltage Offset Correction: v_off_ini = 2574.390 uV, v_off_fin = 2605.417 uV 12:08:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.304 uVs 12:08:17 Integrated Voltage Measurement... 12:08:26 Voltage Offset Correction: v_off_ini = 2599.656 uV, v_off_fin = 2611.943 uV 12:08:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.660 uVs 12:08:26 Integrated Voltage Measurement... 12:08:35 Voltage Offset Correction: v_off_ini = 2633.547 uV, v_off_fin = 2640.037 uV 12:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.382 uVs 12:08:39 I1X Average and RMS of Measurements VT = -70.208 +- 4.980 uVs I1X = 14.042 +- 0.996 uTm 12:08:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:08:46 Integrated Voltage Measurement... 12:08:55 Voltage Offset Correction: v_off_ini = 2640.154 uV, v_off_fin = 2624.507 uV 12:08:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.804 uVs 12:08:55 Integrated Voltage Measurement... 12:09:04 Voltage Offset Correction: v_off_ini = 2638.634 uV, v_off_fin = 2631.011 uV 12:09:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.406 uVs 12:09:04 Integrated Voltage Measurement... 12:09:13 Voltage Offset Correction: v_off_ini = 2619.461 uV, v_off_fin = 2606.412 uV 12:09:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.975 uVs 12:09:13 Integrated Voltage Measurement... 12:09:22 Voltage Offset Correction: v_off_ini = 2595.741 uV, v_off_fin = 2611.454 uV 12:09:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.057 uVs 12:09:22 Integrated Voltage Measurement... 12:09:31 Voltage Offset Correction: v_off_ini = 2609.307 uV, v_off_fin = 2608.446 uV 12:09:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.122 uVs 12:09:31 Integrated Voltage Measurement... 12:09:40 Voltage Offset Correction: v_off_ini = 2620.787 uV, v_off_fin = 2620.680 uV 12:09:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.431 uVs 12:09:44 I1Y Average and RMS of Measurements VT = -244.133 +- 9.634 uVs I1Y = -48.827 +- 1.927 uTm 12:09:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:09:51 Integrated Voltage Measurement... 12:10:00 Voltage Offset Correction: v_off_ini = 2588.065 uV, v_off_fin = 2623.441 uV 12:10:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.708 uVs 12:10:01 Integrated Voltage Measurement... 12:10:09 Voltage Offset Correction: v_off_ini = 2612.220 uV, v_off_fin = 2630.567 uV 12:10:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.829 uVs 12:10:10 Integrated Voltage Measurement... 12:10:19 Voltage Offset Correction: v_off_ini = 2581.333 uV, v_off_fin = 2618.472 uV 12:10:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.178 uVs 12:10:19 Integrated Voltage Measurement... 12:10:28 Voltage Offset Correction: v_off_ini = 2643.257 uV, v_off_fin = 2633.223 uV 12:10:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.513 uVs 12:10:28 Integrated Voltage Measurement... 12:10:37 Voltage Offset Correction: v_off_ini = 2622.953 uV, v_off_fin = 2605.238 uV 12:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.674 uVs 12:10:37 Integrated Voltage Measurement... 12:10:46 Voltage Offset Correction: v_off_ini = 2605.207 uV, v_off_fin = 2608.036 uV 12:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.950 uVs 12:10:48 I2X Average and RMS of Measurements VT = -63.142 +- 13.508 uVs I2X = 5.809 +- 1.243 uTm^2 12:10:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:10:56 Integrated Voltage Measurement... 12:11:05 Voltage Offset Correction: v_off_ini = 2628.100 uV, v_off_fin = 2618.098 uV 12:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -361.849 uVs 12:11:05 Integrated Voltage Measurement... 12:11:14 Voltage Offset Correction: v_off_ini = 2634.985 uV, v_off_fin = 2625.279 uV 12:11:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 390.232 uVs 12:11:14 Integrated Voltage Measurement... 12:11:23 Voltage Offset Correction: v_off_ini = 2617.423 uV, v_off_fin = 2619.756 uV 12:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.670 uVs 12:11:23 Integrated Voltage Measurement... 12:11:32 Voltage Offset Correction: v_off_ini = 2628.291 uV, v_off_fin = 2625.678 uV 12:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 418.973 uVs 12:11:32 Integrated Voltage Measurement... 12:11:41 Voltage Offset Correction: v_off_ini = 2634.618 uV, v_off_fin = 2629.975 uV 12:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.335 uVs 12:11:41 Integrated Voltage Measurement... 12:11:50 Voltage Offset Correction: v_off_ini = 2642.124 uV, v_off_fin = 2638.259 uV 12:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 380.077 uVs 12:11:52 I2Y Average and RMS of Measurements VT = -385.856 +- 16.666 uVs I2Y = -35.499 +- 1.533 uTm^2 12:11:57 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:12:01 Integrated Voltage Measurement... 12:12:10 Voltage Offset Correction: v_off_ini = 2681.859 uV, v_off_fin = 2672.682 uV 12:12:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -89.379 uVs 12:12:10 Integrated Voltage Measurement... 12:12:19 Voltage Offset Correction: v_off_ini = 2659.058 uV, v_off_fin = 2660.911 uV 12:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.209 uVs 12:12:19 Integrated Voltage Measurement... 12:12:28 Voltage Offset Correction: v_off_ini = 2686.713 uV, v_off_fin = 2667.636 uV 12:12:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.074 uVs 12:12:28 Integrated Voltage Measurement... 12:12:37 Voltage Offset Correction: v_off_ini = 2656.126 uV, v_off_fin = 2665.020 uV 12:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.169 uVs 12:12:37 Integrated Voltage Measurement... 12:12:46 Voltage Offset Correction: v_off_ini = 2657.354 uV, v_off_fin = 2669.550 uV 12:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -7.745 uVs 12:12:46 Integrated Voltage Measurement... 12:12:55 Voltage Offset Correction: v_off_ini = 2680.876 uV, v_off_fin = 2663.172 uV 12:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.538 uVs 12:12:59 I1X Average and RMS of Measurements VT = -41.686 +- 15.375 uVs I1X = 8.338 +- 3.076 uTm 12:13:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:13:06 Integrated Voltage Measurement... 12:13:15 Voltage Offset Correction: v_off_ini = 2660.354 uV, v_off_fin = 2640.454 uV 12:13:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -240.911 uVs 12:13:15 Integrated Voltage Measurement... 12:13:24 Voltage Offset Correction: v_off_ini = 2654.451 uV, v_off_fin = 2665.780 uV 12:13:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.236 uVs 12:13:24 Integrated Voltage Measurement... 12:13:33 Voltage Offset Correction: v_off_ini = 2648.277 uV, v_off_fin = 2643.874 uV 12:13:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.868 uVs 12:13:33 Integrated Voltage Measurement... 12:13:42 Voltage Offset Correction: v_off_ini = 2653.989 uV, v_off_fin = 2655.359 uV 12:13:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.776 uVs 12:13:42 Integrated Voltage Measurement... 12:13:51 Voltage Offset Correction: v_off_ini = 2638.689 uV, v_off_fin = 2648.399 uV 12:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.473 uVs 12:13:51 Integrated Voltage Measurement... 12:14:00 Voltage Offset Correction: v_off_ini = 2654.390 uV, v_off_fin = 2674.875 uV 12:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.613 uVs 12:14:04 I1Y Average and RMS of Measurements VT = -245.479 +- 6.323 uVs I1Y = -49.097 +- 1.266 uTm 12:14:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:14:12 Integrated Voltage Measurement... 12:14:21 Voltage Offset Correction: v_off_ini = 2653.959 uV, v_off_fin = 2639.769 uV 12:14:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.885 uVs 12:14:21 Integrated Voltage Measurement... 12:14:30 Voltage Offset Correction: v_off_ini = 2657.637 uV, v_off_fin = 2671.996 uV 12:14:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.480 uVs 12:14:30 Integrated Voltage Measurement... 12:14:39 Voltage Offset Correction: v_off_ini = 2663.263 uV, v_off_fin = 2656.140 uV 12:14:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.326 uVs 12:14:39 Integrated Voltage Measurement... 12:14:48 Voltage Offset Correction: v_off_ini = 2642.606 uV, v_off_fin = 2669.127 uV 12:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.280 uVs 12:14:48 Integrated Voltage Measurement... 12:14:57 Voltage Offset Correction: v_off_ini = 2687.246 uV, v_off_fin = 2649.821 uV 12:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.043 uVs 12:14:57 Integrated Voltage Measurement... 12:15:06 Voltage Offset Correction: v_off_ini = 2679.973 uV, v_off_fin = 2677.404 uV 12:15:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 18.800 uVs 12:15:08 I2X Average and RMS of Measurements VT = -30.136 +- 12.174 uVs I2X = 2.773 +- 1.120 uTm^2 12:15:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:15:16 Integrated Voltage Measurement... 12:15:25 Voltage Offset Correction: v_off_ini = 2642.397 uV, v_off_fin = 2651.251 uV 12:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -358.147 uVs 12:15:25 Integrated Voltage Measurement... 12:15:34 Voltage Offset Correction: v_off_ini = 2655.941 uV, v_off_fin = 2673.959 uV 12:15:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 413.415 uVs 12:15:34 Integrated Voltage Measurement... 12:15:43 Voltage Offset Correction: v_off_ini = 2675.417 uV, v_off_fin = 2685.583 uV 12:15:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -369.131 uVs 12:15:43 Integrated Voltage Measurement... 12:15:52 Voltage Offset Correction: v_off_ini = 2687.944 uV, v_off_fin = 2682.493 uV 12:15:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 394.564 uVs 12:15:52 Integrated Voltage Measurement... 12:16:01 Voltage Offset Correction: v_off_ini = 2670.800 uV, v_off_fin = 2707.464 uV 12:16:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -398.206 uVs 12:16:01 Integrated Voltage Measurement... 12:16:10 Voltage Offset Correction: v_off_ini = 2681.022 uV, v_off_fin = 2686.788 uV 12:16:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 401.347 uVs 12:16:13 I2Y Average and RMS of Measurements VT = -389.135 +- 7.694 uVs I2Y = -35.802 +- 0.707 uTm^2 12:16:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:16:25 Integrated Voltage Measurement... 12:16:33 Voltage Offset Correction: v_off_ini = 2669.451 uV, v_off_fin = 2648.287 uV 12:16:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.271 uVs 12:16:34 Integrated Voltage Measurement... 12:16:42 Voltage Offset Correction: v_off_ini = 2629.312 uV, v_off_fin = 2670.835 uV 12:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.742 uVs 12:16:43 Integrated Voltage Measurement... 12:16:51 Voltage Offset Correction: v_off_ini = 2691.270 uV, v_off_fin = 2675.223 uV 12:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.641 uVs 12:16:52 Integrated Voltage Measurement... 12:17:00 Voltage Offset Correction: v_off_ini = 2661.641 uV, v_off_fin = 2652.348 uV 12:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.168 uVs 12:17:01 Integrated Voltage Measurement... 12:17:09 Voltage Offset Correction: v_off_ini = 2606.565 uV, v_off_fin = 2612.928 uV 12:17:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.766 uVs 12:17:10 Integrated Voltage Measurement... 12:17:19 Voltage Offset Correction: v_off_ini = 2629.625 uV, v_off_fin = 2662.164 uV 12:17:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.429 uVs 12:17:23 I1X Average and RMS of Measurements VT = -71.336 +- 13.137 uVs I1X = 14.268 +- 2.627 uTm 12:17:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:17:29 Integrated Voltage Measurement... 12:17:38 Voltage Offset Correction: v_off_ini = 2649.980 uV, v_off_fin = 2625.651 uV 12:17:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.352 uVs 12:17:38 Integrated Voltage Measurement... 12:17:47 Voltage Offset Correction: v_off_ini = 2635.970 uV, v_off_fin = 2654.811 uV 12:17:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.460 uVs 12:17:47 Integrated Voltage Measurement... 12:17:56 Voltage Offset Correction: v_off_ini = 2638.602 uV, v_off_fin = 2620.861 uV 12:17:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.388 uVs 12:17:56 Integrated Voltage Measurement... 12:18:05 Voltage Offset Correction: v_off_ini = 2647.566 uV, v_off_fin = 2650.546 uV 12:18:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.694 uVs 12:18:05 Integrated Voltage Measurement... 12:18:14 Voltage Offset Correction: v_off_ini = 2645.369 uV, v_off_fin = 2626.276 uV 12:18:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.424 uVs 12:18:14 Integrated Voltage Measurement... 12:18:23 Voltage Offset Correction: v_off_ini = 2655.770 uV, v_off_fin = 2663.782 uV 12:18:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.590 uVs 12:18:28 I1Y Average and RMS of Measurements VT = -254.652 +- 5.192 uVs I1Y = -50.930 +- 1.038 uTm 12:18:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:18:33 Integrated Voltage Measurement... 12:18:42 Voltage Offset Correction: v_off_ini = 2626.787 uV, v_off_fin = 2633.352 uV 12:18:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -126.111 uVs 12:18:42 Integrated Voltage Measurement... 12:18:51 Voltage Offset Correction: v_off_ini = 2640.827 uV, v_off_fin = 2620.269 uV 12:18:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.140 uVs 12:18:51 Integrated Voltage Measurement... 12:19:00 Voltage Offset Correction: v_off_ini = 2620.299 uV, v_off_fin = 2626.570 uV 12:19:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.629 uVs 12:19:00 Integrated Voltage Measurement... 12:19:09 Voltage Offset Correction: v_off_ini = 2597.682 uV, v_off_fin = 2616.572 uV 12:19:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.414 uVs 12:19:09 Integrated Voltage Measurement... 12:19:18 Voltage Offset Correction: v_off_ini = 2663.458 uV, v_off_fin = 2644.489 uV 12:19:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.712 uVs 12:19:18 Integrated Voltage Measurement... 12:19:27 Voltage Offset Correction: v_off_ini = 2633.958 uV, v_off_fin = 2640.674 uV 12:19:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.882 uVs 12:19:29 I2X Average and RMS of Measurements VT = -85.481 +- 24.608 uVs I2X = 7.864 +- 2.264 uTm^2 12:19:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:19:34 Integrated Voltage Measurement... 12:19:43 Voltage Offset Correction: v_off_ini = 2647.063 uV, v_off_fin = 2644.181 uV 12:19:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -419.427 uVs 12:19:43 Integrated Voltage Measurement... 12:19:52 Voltage Offset Correction: v_off_ini = 2639.959 uV, v_off_fin = 2646.780 uV 12:19:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 404.910 uVs 12:19:52 Integrated Voltage Measurement... 12:20:01 Voltage Offset Correction: v_off_ini = 2649.412 uV, v_off_fin = 2634.774 uV 12:20:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -404.582 uVs 12:20:01 Integrated Voltage Measurement... 12:20:10 Voltage Offset Correction: v_off_ini = 2629.191 uV, v_off_fin = 2619.699 uV 12:20:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.947 uVs 12:20:10 Integrated Voltage Measurement... 12:20:19 Voltage Offset Correction: v_off_ini = 2635.258 uV, v_off_fin = 2621.332 uV 12:20:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -380.017 uVs 12:20:19 Integrated Voltage Measurement... 12:20:28 Voltage Offset Correction: v_off_ini = 2624.377 uV, v_off_fin = 2615.318 uV 12:20:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.574 uVs 12:20:31 I2Y Average and RMS of Measurements VT = -395.243 +- 15.204 uVs I2Y = -36.362 +- 1.399 uTm^2 12:20:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:20:39 Integrated Voltage Measurement... 12:20:48 Voltage Offset Correction: v_off_ini = 2633.714 uV, v_off_fin = 2631.133 uV 12:20:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -55.316 uVs 12:20:48 Integrated Voltage Measurement... 12:20:57 Voltage Offset Correction: v_off_ini = 2624.066 uV, v_off_fin = 2635.683 uV 12:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.716 uVs 12:20:57 Integrated Voltage Measurement... 12:21:06 Voltage Offset Correction: v_off_ini = 2632.681 uV, v_off_fin = 2626.454 uV 12:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.260 uVs 12:21:06 Integrated Voltage Measurement... 12:21:15 Voltage Offset Correction: v_off_ini = 2648.271 uV, v_off_fin = 2627.574 uV 12:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 46.810 uVs 12:21:15 Integrated Voltage Measurement... 12:21:24 Voltage Offset Correction: v_off_ini = 2649.274 uV, v_off_fin = 2654.996 uV 12:21:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -80.390 uVs 12:21:24 Integrated Voltage Measurement... 12:21:33 Voltage Offset Correction: v_off_ini = 2645.610 uV, v_off_fin = 2636.318 uV 12:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 93.708 uVs 12:21:37 I1X Average and RMS of Measurements VT = -70.367 +- 11.860 uVs I1X = 14.075 +- 2.373 uTm 12:21:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:21:44 Integrated Voltage Measurement... 12:21:53 Voltage Offset Correction: v_off_ini = 2638.431 uV, v_off_fin = 2651.282 uV 12:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.117 uVs 12:21:53 Integrated Voltage Measurement... 12:22:02 Voltage Offset Correction: v_off_ini = 2671.241 uV, v_off_fin = 2672.311 uV 12:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.095 uVs 12:22:02 Integrated Voltage Measurement... 12:22:11 Voltage Offset Correction: v_off_ini = 2670.473 uV, v_off_fin = 2633.160 uV 12:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.787 uVs 12:22:11 Integrated Voltage Measurement... 12:22:20 Voltage Offset Correction: v_off_ini = 2614.128 uV, v_off_fin = 2683.416 uV 12:22:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.203 uVs 12:22:20 Integrated Voltage Measurement... 12:22:29 Voltage Offset Correction: v_off_ini = 2671.174 uV, v_off_fin = 2629.355 uV 12:22:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.438 uVs 12:22:29 Integrated Voltage Measurement... 12:22:38 Voltage Offset Correction: v_off_ini = 2656.640 uV, v_off_fin = 2663.479 uV 12:22:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.983 uVs 12:22:42 I1Y Average and RMS of Measurements VT = -253.104 +- 14.129 uVs I1Y = -50.621 +- 2.826 uTm 12:22:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:22:47 Integrated Voltage Measurement... 12:22:56 Voltage Offset Correction: v_off_ini = 2641.424 uV, v_off_fin = 2617.148 uV 12:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.197 uVs 12:22:56 Integrated Voltage Measurement... 12:23:05 Voltage Offset Correction: v_off_ini = 2638.913 uV, v_off_fin = 2637.183 uV 12:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.147 uVs 12:23:05 Integrated Voltage Measurement... 12:23:14 Voltage Offset Correction: v_off_ini = 2661.859 uV, v_off_fin = 2639.129 uV 12:23:14 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -101.244 uVs 12:23:14 Integrated Voltage Measurement... 12:23:23 Voltage Offset Correction: v_off_ini = 2651.892 uV, v_off_fin = 2645.937 uV 12:23:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.850 uVs 12:23:23 Integrated Voltage Measurement... 12:23:32 Voltage Offset Correction: v_off_ini = 2676.241 uV, v_off_fin = 2640.726 uV 12:23:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.657 uVs 12:23:32 Integrated Voltage Measurement... 12:23:41 Voltage Offset Correction: v_off_ini = 2636.285 uV, v_off_fin = 2649.292 uV 12:23:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.717 uVs 12:23:44 I2X Average and RMS of Measurements VT = -85.302 +- 14.492 uVs I2X = 7.848 +- 1.334 uTm^2 12:23:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:23:49 Integrated Voltage Measurement... 12:23:58 Voltage Offset Correction: v_off_ini = 2666.865 uV, v_off_fin = 2646.489 uV 12:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -396.091 uVs 12:23:58 Integrated Voltage Measurement... 12:24:07 Voltage Offset Correction: v_off_ini = 2660.473 uV, v_off_fin = 2656.208 uV 12:24:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 361.467 uVs 12:24:07 Integrated Voltage Measurement... 12:24:16 Voltage Offset Correction: v_off_ini = 2653.284 uV, v_off_fin = 2650.565 uV 12:24:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -393.974 uVs 12:24:16 Integrated Voltage Measurement... 12:24:25 Voltage Offset Correction: v_off_ini = 2658.179 uV, v_off_fin = 2669.496 uV 12:24:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.896 uVs 12:24:25 Integrated Voltage Measurement... 12:24:34 Voltage Offset Correction: v_off_ini = 2664.838 uV, v_off_fin = 2645.822 uV 12:24:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.162 uVs 12:24:34 Integrated Voltage Measurement... 12:24:43 Voltage Offset Correction: v_off_ini = 2656.972 uV, v_off_fin = 2645.030 uV 12:24:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 409.428 uVs 12:24:45 I2Y Average and RMS of Measurements VT = -389.336 +- 10.294 uVs I2Y = -35.819 +- 0.946 uTm^2 12:24:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:54 Integrated Voltage Measurement... 12:25:03 Voltage Offset Correction: v_off_ini = 2645.614 uV, v_off_fin = 2664.645 uV 12:25:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.641 uVs 12:25:03 Integrated Voltage Measurement... 12:25:12 Voltage Offset Correction: v_off_ini = 2640.289 uV, v_off_fin = 2654.940 uV 12:25:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.875 uVs 12:25:12 Integrated Voltage Measurement... 12:25:21 Voltage Offset Correction: v_off_ini = 2661.432 uV, v_off_fin = 2649.981 uV 12:25:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -52.916 uVs 12:25:21 Integrated Voltage Measurement... 12:25:30 Voltage Offset Correction: v_off_ini = 2677.186 uV, v_off_fin = 2682.627 uV 12:25:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.568 uVs 12:25:30 Integrated Voltage Measurement... 12:25:39 Voltage Offset Correction: v_off_ini = 2689.778 uV, v_off_fin = 2656.114 uV 12:25:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.389 uVs 12:25:39 Integrated Voltage Measurement... 12:25:48 Voltage Offset Correction: v_off_ini = 2657.710 uV, v_off_fin = 2675.976 uV 12:25:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.655 uVs 12:25:52 I1X Average and RMS of Measurements VT = -76.341 +- 6.718 uVs I1X = 15.269 +- 1.344 uTm 12:25:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:59 Integrated Voltage Measurement... 12:26:07 Voltage Offset Correction: v_off_ini = 2659.700 uV, v_off_fin = 2649.850 uV 12:26:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.594 uVs 12:26:08 Integrated Voltage Measurement... 12:26:16 Voltage Offset Correction: v_off_ini = 2655.164 uV, v_off_fin = 2669.253 uV 12:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.668 uVs 12:26:17 Integrated Voltage Measurement... 12:26:25 Voltage Offset Correction: v_off_ini = 2662.067 uV, v_off_fin = 2651.176 uV 12:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.216 uVs 12:26:25 Integrated Voltage Measurement... 12:26:34 Voltage Offset Correction: v_off_ini = 2648.990 uV, v_off_fin = 2668.288 uV 12:26:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.674 uVs 12:26:34 Integrated Voltage Measurement... 12:26:43 Voltage Offset Correction: v_off_ini = 2655.023 uV, v_off_fin = 2652.521 uV 12:26:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -241.269 uVs 12:26:43 Integrated Voltage Measurement... 12:26:52 Voltage Offset Correction: v_off_ini = 2648.723 uV, v_off_fin = 2636.944 uV 12:26:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.941 uVs 12:26:57 I1Y Average and RMS of Measurements VT = -235.060 +- 6.496 uVs I1Y = -47.014 +- 1.299 uTm 12:26:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:02 Integrated Voltage Measurement... 12:27:11 Voltage Offset Correction: v_off_ini = 2649.758 uV, v_off_fin = 2617.975 uV 12:27:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.553 uVs 12:27:11 Integrated Voltage Measurement... 12:27:20 Voltage Offset Correction: v_off_ini = 2629.261 uV, v_off_fin = 2625.067 uV 12:27:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.058 uVs 12:27:20 Integrated Voltage Measurement... 12:27:29 Voltage Offset Correction: v_off_ini = 2629.555 uV, v_off_fin = 2630.889 uV 12:27:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.461 uVs 12:27:29 Integrated Voltage Measurement... 12:27:38 Voltage Offset Correction: v_off_ini = 2648.448 uV, v_off_fin = 2643.580 uV 12:27:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.012 uVs 12:27:38 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = 2630.816 uV, v_off_fin = 2635.600 uV 12:27:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.366 uVs 12:27:47 Integrated Voltage Measurement... 12:27:56 Voltage Offset Correction: v_off_ini = 2617.700 uV, v_off_fin = 2633.034 uV 12:27:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.742 uVs 12:27:58 I2X Average and RMS of Measurements VT = -66.032 +- 7.765 uVs I2X = 6.075 +- 0.714 uTm^2 12:28:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:03 Integrated Voltage Measurement... 12:28:12 Voltage Offset Correction: v_off_ini = 2640.753 uV, v_off_fin = 2607.042 uV 12:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.395 uVs 12:28:12 Integrated Voltage Measurement... 12:28:21 Voltage Offset Correction: v_off_ini = 2607.354 uV, v_off_fin = 2620.446 uV 12:28:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 399.226 uVs 12:28:21 Integrated Voltage Measurement... 12:28:30 Voltage Offset Correction: v_off_ini = 2632.607 uV, v_off_fin = 2604.514 uV 12:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.664 uVs 12:28:30 Integrated Voltage Measurement... 12:28:39 Voltage Offset Correction: v_off_ini = 2620.812 uV, v_off_fin = 2647.449 uV 12:28:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 379.093 uVs 12:28:39 Integrated Voltage Measurement... 12:28:48 Voltage Offset Correction: v_off_ini = 2644.968 uV, v_off_fin = 2625.265 uV 12:28:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -381.763 uVs 12:28:48 Integrated Voltage Measurement... 12:28:57 Voltage Offset Correction: v_off_ini = 2621.913 uV, v_off_fin = 2670.268 uV 12:28:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 383.420 uVs 12:29:00 I2Y Average and RMS of Measurements VT = -377.260 +- 11.817 uVs I2Y = -34.708 +- 1.087 uTm^2 12:29:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:29:08 Integrated Voltage Measurement... 12:29:17 Voltage Offset Correction: v_off_ini = 2670.120 uV, v_off_fin = 2684.929 uV 12:29:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.051 uVs 12:29:17 Integrated Voltage Measurement... 12:29:26 Voltage Offset Correction: v_off_ini = 2669.678 uV, v_off_fin = 2691.509 uV 12:29:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.121 uVs 12:29:26 Integrated Voltage Measurement... 12:29:35 Voltage Offset Correction: v_off_ini = 2672.025 uV, v_off_fin = 2658.665 uV 12:29:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.097 uVs 12:29:35 Integrated Voltage Measurement... 12:29:44 Voltage Offset Correction: v_off_ini = 2656.054 uV, v_off_fin = 2687.109 uV 12:29:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.589 uVs 12:29:44 Integrated Voltage Measurement... 12:29:53 Voltage Offset Correction: v_off_ini = 2671.856 uV, v_off_fin = 2652.750 uV 12:29:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.217 uVs 12:29:53 Integrated Voltage Measurement... 12:30:02 Voltage Offset Correction: v_off_ini = 2642.292 uV, v_off_fin = 2655.673 uV 12:30:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.130 uVs 12:30:06 I1X Average and RMS of Measurements VT = -58.201 +- 8.899 uVs I1X = 11.640 +- 1.780 uTm 12:30:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:30:13 Integrated Voltage Measurement... 12:30:22 Voltage Offset Correction: v_off_ini = 2657.231 uV, v_off_fin = 2648.668 uV 12:30:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -226.598 uVs 12:30:22 Integrated Voltage Measurement... 12:30:31 Voltage Offset Correction: v_off_ini = 2669.201 uV, v_off_fin = 2663.737 uV 12:30:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 225.644 uVs 12:30:31 Integrated Voltage Measurement... 12:30:40 Voltage Offset Correction: v_off_ini = 2640.046 uV, v_off_fin = 2630.046 uV 12:30:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.035 uVs 12:30:40 Integrated Voltage Measurement... 12:30:49 Voltage Offset Correction: v_off_ini = 2618.939 uV, v_off_fin = 2641.848 uV 12:30:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 233.614 uVs 12:30:49 Integrated Voltage Measurement... 12:30:58 Voltage Offset Correction: v_off_ini = 2648.253 uV, v_off_fin = 2628.331 uV 12:30:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.747 uVs 12:30:58 Integrated Voltage Measurement... 12:31:07 Voltage Offset Correction: v_off_ini = 2620.394 uV, v_off_fin = 2637.393 uV 12:31:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.174 uVs 12:31:11 I1Y Average and RMS of Measurements VT = -225.635 +- 1.614 uVs I1Y = -45.123 +- 0.324 uTm 12:31:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:31:16 Integrated Voltage Measurement... 12:31:25 Voltage Offset Correction: v_off_ini = 2646.852 uV, v_off_fin = 2623.527 uV 12:31:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.492 uVs 12:31:25 Integrated Voltage Measurement... 12:31:34 Voltage Offset Correction: v_off_ini = 2623.853 uV, v_off_fin = 2646.885 uV 12:31:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.240 uVs 12:31:34 Integrated Voltage Measurement... 12:31:43 Voltage Offset Correction: v_off_ini = 2652.086 uV, v_off_fin = 2623.427 uV 12:31:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.448 uVs 12:31:43 Integrated Voltage Measurement... 12:31:52 Voltage Offset Correction: v_off_ini = 2624.538 uV, v_off_fin = 2626.090 uV 12:31:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.343 uVs 12:31:52 Integrated Voltage Measurement... 12:32:01 Voltage Offset Correction: v_off_ini = 2643.385 uV, v_off_fin = 2640.063 uV 12:32:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.495 uVs 12:32:01 Integrated Voltage Measurement... 12:32:10 Voltage Offset Correction: v_off_ini = 2648.512 uV, v_off_fin = 2666.710 uV 12:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.141 uVs 12:32:12 I2X Average and RMS of Measurements VT = -76.527 +- 6.892 uVs I2X = 7.040 +- 0.634 uTm^2 12:32:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:32:17 Integrated Voltage Measurement... 12:32:26 Voltage Offset Correction: v_off_ini = 2634.789 uV, v_off_fin = 2649.360 uV 12:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -399.119 uVs 12:32:26 Integrated Voltage Measurement... 12:32:35 Voltage Offset Correction: v_off_ini = 2634.584 uV, v_off_fin = 2633.588 uV 12:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 411.786 uVs 12:32:35 Integrated Voltage Measurement... 12:32:44 Voltage Offset Correction: v_off_ini = 2632.493 uV, v_off_fin = 2621.827 uV 12:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.061 uVs 12:32:44 Integrated Voltage Measurement... 12:32:53 Voltage Offset Correction: v_off_ini = 2614.448 uV, v_off_fin = 2633.590 uV 12:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.032 uVs 12:32:53 Integrated Voltage Measurement... 12:33:02 Voltage Offset Correction: v_off_ini = 2615.227 uV, v_off_fin = 2595.419 uV 12:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -370.163 uVs 12:33:02 Integrated Voltage Measurement... 12:33:11 Voltage Offset Correction: v_off_ini = 2579.744 uV, v_off_fin = 2602.530 uV 12:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 381.824 uVs 12:33:14 I2Y Average and RMS of Measurements VT = -383.331 +- 15.935 uVs I2Y = -35.266 +- 1.466 uTm^2 12:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:33:22 Integrated Voltage Measurement... 12:33:31 Voltage Offset Correction: v_off_ini = 2618.608 uV, v_off_fin = 2583.909 uV 12:33:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -118.013 uVs 12:33:31 Integrated Voltage Measurement... 12:33:40 Voltage Offset Correction: v_off_ini = 2612.429 uV, v_off_fin = 2587.150 uV 12:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.517 uVs 12:33:40 Integrated Voltage Measurement... 12:33:49 Voltage Offset Correction: v_off_ini = 2573.062 uV, v_off_fin = 2602.995 uV 12:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.454 uVs 12:33:49 Integrated Voltage Measurement... 12:33:58 Voltage Offset Correction: v_off_ini = 2606.531 uV, v_off_fin = 2611.085 uV 12:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.129 uVs 12:33:58 Integrated Voltage Measurement... 12:34:07 Voltage Offset Correction: v_off_ini = 2614.157 uV, v_off_fin = 2635.671 uV 12:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.853 uVs 12:34:07 Integrated Voltage Measurement... 12:34:16 Voltage Offset Correction: v_off_ini = 2662.408 uV, v_off_fin = 2638.920 uV 12:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.472 uVs 12:34:20 I1X Average and RMS of Measurements VT = -59.906 +- 14.911 uVs I1X = 11.982 +- 2.984 uTm 12:34:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:34:27 Integrated Voltage Measurement... 12:34:36 Voltage Offset Correction: v_off_ini = 2663.077 uV, v_off_fin = 2636.026 uV 12:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -223.684 uVs 12:34:36 Integrated Voltage Measurement... 12:34:45 Voltage Offset Correction: v_off_ini = 2646.629 uV, v_off_fin = 2657.197 uV 12:34:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.927 uVs 12:34:45 Integrated Voltage Measurement... 12:34:54 Voltage Offset Correction: v_off_ini = 2652.533 uV, v_off_fin = 2627.283 uV 12:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.411 uVs 12:34:54 Integrated Voltage Measurement... 12:35:03 Voltage Offset Correction: v_off_ini = 2618.985 uV, v_off_fin = 2667.653 uV 12:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.059 uVs 12:35:03 Integrated Voltage Measurement... 12:35:12 Voltage Offset Correction: v_off_ini = 2657.570 uV, v_off_fin = 2644.973 uV 12:35:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.110 uVs 12:35:12 Integrated Voltage Measurement... 12:35:21 Voltage Offset Correction: v_off_ini = 2645.976 uV, v_off_fin = 2665.832 uV 12:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.277 uVs 12:35:25 I1Y Average and RMS of Measurements VT = -228.078 +- 6.989 uVs I1Y = -45.613 +- 1.398 uTm 12:35:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:35:30 Integrated Voltage Measurement... 12:35:39 Voltage Offset Correction: v_off_ini = 2619.712 uV, v_off_fin = 2640.811 uV 12:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.974 uVs 12:35:39 Integrated Voltage Measurement... 12:35:48 Voltage Offset Correction: v_off_ini = 2670.425 uV, v_off_fin = 2670.388 uV 12:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.261 uVs 12:35:48 Integrated Voltage Measurement... 12:35:57 Voltage Offset Correction: v_off_ini = 2666.718 uV, v_off_fin = 2649.766 uV 12:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.702 uVs 12:35:57 Integrated Voltage Measurement... 12:36:06 Voltage Offset Correction: v_off_ini = 2608.067 uV, v_off_fin = 2645.003 uV 12:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.257 uVs 12:36:06 Integrated Voltage Measurement... 12:36:15 Voltage Offset Correction: v_off_ini = 2659.695 uV, v_off_fin = 2646.789 uV 12:36:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.116 uVs 12:36:15 Integrated Voltage Measurement... 12:36:24 Voltage Offset Correction: v_off_ini = 2645.806 uV, v_off_fin = 2669.109 uV 12:36:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.871 uVs 12:36:27 I2X Average and RMS of Measurements VT = -60.530 +- 8.771 uVs I2X = 5.569 +- 0.807 uTm^2 12:36:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:36:32 Integrated Voltage Measurement... 12:36:41 Voltage Offset Correction: v_off_ini = 2670.508 uV, v_off_fin = 2660.168 uV 12:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -395.564 uVs 12:36:41 Integrated Voltage Measurement... 12:36:50 Voltage Offset Correction: v_off_ini = 2626.833 uV, v_off_fin = 2685.985 uV 12:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.818 uVs 12:36:50 Integrated Voltage Measurement... 12:36:59 Voltage Offset Correction: v_off_ini = 2688.828 uV, v_off_fin = 2696.538 uV 12:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.489 uVs 12:36:59 Integrated Voltage Measurement... 12:37:08 Voltage Offset Correction: v_off_ini = 2675.763 uV, v_off_fin = 2679.182 uV 12:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 360.108 uVs 12:37:08 Integrated Voltage Measurement... 12:37:17 Voltage Offset Correction: v_off_ini = 2680.143 uV, v_off_fin = 2674.364 uV 12:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.435 uVs 12:37:17 Integrated Voltage Measurement... 12:37:26 Voltage Offset Correction: v_off_ini = 2693.443 uV, v_off_fin = 2700.036 uV 12:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.805 uVs 12:37:28 I2Y Average and RMS of Measurements VT = -381.536 +- 17.592 uVs I2Y = -35.101 +- 1.618 uTm^2 12:37:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:37:50 Integrated Voltage Measurement... 12:37:59 Voltage Offset Correction: v_off_ini = 2680.510 uV, v_off_fin = 2659.316 uV 12:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.083 uVs 12:37:59 Integrated Voltage Measurement... 12:38:08 Voltage Offset Correction: v_off_ini = 2691.145 uV, v_off_fin = 2688.623 uV 12:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.258 uVs 12:38:08 Integrated Voltage Measurement... 12:38:17 Voltage Offset Correction: v_off_ini = 2692.650 uV, v_off_fin = 2681.070 uV 12:38:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.700 uVs 12:38:17 Integrated Voltage Measurement... 12:38:26 Voltage Offset Correction: v_off_ini = 2678.903 uV, v_off_fin = 2659.375 uV 12:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 89.025 uVs 12:38:26 Integrated Voltage Measurement... 12:38:35 Voltage Offset Correction: v_off_ini = 2651.402 uV, v_off_fin = 2658.370 uV 12:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.394 uVs 12:38:35 Integrated Voltage Measurement... 12:38:44 Voltage Offset Correction: v_off_ini = 2671.562 uV, v_off_fin = 2679.002 uV 12:38:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.114 uVs 12:38:48 I1X Average and RMS of Measurements VT = -95.929 +- 1.920 uVs I1X = 19.186 +- 0.384 uTm 12:38:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:38:55 Integrated Voltage Measurement... 12:39:04 Voltage Offset Correction: v_off_ini = 2621.701 uV, v_off_fin = 2606.309 uV 12:39:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.216 uVs 12:39:04 Integrated Voltage Measurement... 12:39:13 Voltage Offset Correction: v_off_ini = 2642.490 uV, v_off_fin = 2655.630 uV 12:39:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.257 uVs 12:39:13 Integrated Voltage Measurement... 12:39:22 Voltage Offset Correction: v_off_ini = 2626.005 uV, v_off_fin = 2613.648 uV 12:39:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.429 uVs 12:39:22 Integrated Voltage Measurement... 12:39:30 Voltage Offset Correction: v_off_ini = 2635.563 uV, v_off_fin = 2638.351 uV 12:39:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 199.073 uVs 12:39:31 Integrated Voltage Measurement... 12:39:39 Voltage Offset Correction: v_off_ini = 2632.385 uV, v_off_fin = 2615.033 uV 12:39:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.913 uVs 12:39:40 Integrated Voltage Measurement... 12:39:48 Voltage Offset Correction: v_off_ini = 2623.242 uV, v_off_fin = 2627.425 uV 12:39:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.088 uVs 12:39:53 I1Y Average and RMS of Measurements VT = -211.663 +- 6.693 uVs I1Y = -42.332 +- 1.337 uTm 12:39:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:40:00 Integrated Voltage Measurement... 12:40:09 Voltage Offset Correction: v_off_ini = 2604.016 uV, v_off_fin = 2612.844 uV 12:40:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.309 uVs 12:40:09 Integrated Voltage Measurement... 12:40:18 Voltage Offset Correction: v_off_ini = 2639.096 uV, v_off_fin = 2630.179 uV 12:40:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.060 uVs 12:40:18 Integrated Voltage Measurement... 12:40:27 Voltage Offset Correction: v_off_ini = 2610.923 uV, v_off_fin = 2617.123 uV 12:40:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.190 uVs 12:40:28 Integrated Voltage Measurement... 12:40:36 Voltage Offset Correction: v_off_ini = 2641.124 uV, v_off_fin = 2636.970 uV 12:40:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.918 uVs 12:40:37 Integrated Voltage Measurement... 12:40:46 Voltage Offset Correction: v_off_ini = 2637.092 uV, v_off_fin = 2636.395 uV 12:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.104 uVs 12:40:46 Integrated Voltage Measurement... 12:40:55 Voltage Offset Correction: v_off_ini = 2611.037 uV, v_off_fin = 2622.143 uV 12:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.271 uVs 12:40:57 I2X Average and RMS of Measurements VT = -95.809 +- 11.326 uVs I2X = 8.815 +- 1.042 uTm^2 12:41:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:41:05 Integrated Voltage Measurement... 12:41:14 Voltage Offset Correction: v_off_ini = 2609.010 uV, v_off_fin = 2588.153 uV 12:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.541 uVs 12:41:14 Integrated Voltage Measurement... 12:41:23 Voltage Offset Correction: v_off_ini = 2627.985 uV, v_off_fin = 2603.725 uV 12:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.362 uVs 12:41:23 Integrated Voltage Measurement... 12:41:32 Voltage Offset Correction: v_off_ini = 2644.493 uV, v_off_fin = 2615.701 uV 12:41:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -367.429 uVs 12:41:32 Integrated Voltage Measurement... 12:41:41 Voltage Offset Correction: v_off_ini = 2651.911 uV, v_off_fin = 2641.197 uV 12:41:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.756 uVs 12:41:41 Integrated Voltage Measurement... 12:41:50 Voltage Offset Correction: v_off_ini = 2614.531 uV, v_off_fin = 2615.344 uV 12:41:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.170 uVs 12:41:50 Integrated Voltage Measurement... 12:41:59 Voltage Offset Correction: v_off_ini = 2644.824 uV, v_off_fin = 2626.935 uV 12:41:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.705 uVs 12:42:01 I2Y Average and RMS of Measurements VT = -335.827 +- 17.621 uVs I2Y = -30.897 +- 1.622 uTm^2 12:42:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:42:10 Integrated Voltage Measurement... 12:42:19 Voltage Offset Correction: v_off_ini = 2614.640 uV, v_off_fin = 2628.287 uV 12:42:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.055 uVs 12:42:19 Integrated Voltage Measurement... 12:42:28 Voltage Offset Correction: v_off_ini = 2662.524 uV, v_off_fin = 2633.491 uV 12:42:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.960 uVs 12:42:28 Integrated Voltage Measurement... 12:42:37 Voltage Offset Correction: v_off_ini = 2634.394 uV, v_off_fin = 2636.316 uV 12:42:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.315 uVs 12:42:37 Integrated Voltage Measurement... 12:42:46 Voltage Offset Correction: v_off_ini = 2636.268 uV, v_off_fin = 2623.026 uV 12:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.175 uVs 12:42:46 Integrated Voltage Measurement... 12:42:55 Voltage Offset Correction: v_off_ini = 2616.741 uV, v_off_fin = 2617.365 uV 12:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.076 uVs 12:42:55 Integrated Voltage Measurement... 12:43:04 Voltage Offset Correction: v_off_ini = 2639.185 uV, v_off_fin = 2628.563 uV 12:43:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.565 uVs 12:43:08 I1X Average and RMS of Measurements VT = -70.191 +- 13.958 uVs I1X = 14.038 +- 2.791 uTm 12:43:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:43:15 Integrated Voltage Measurement... 12:43:24 Voltage Offset Correction: v_off_ini = 2626.632 uV, v_off_fin = 2620.721 uV 12:43:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.521 uVs 12:43:24 Integrated Voltage Measurement... 12:43:33 Voltage Offset Correction: v_off_ini = 2631.932 uV, v_off_fin = 2652.398 uV 12:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.241 uVs 12:43:33 Integrated Voltage Measurement... 12:43:42 Voltage Offset Correction: v_off_ini = 2651.282 uV, v_off_fin = 2629.899 uV 12:43:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.702 uVs 12:43:42 Integrated Voltage Measurement... 12:43:51 Voltage Offset Correction: v_off_ini = 2641.565 uV, v_off_fin = 2650.447 uV 12:43:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.215 uVs 12:43:51 Integrated Voltage Measurement... 12:44:00 Voltage Offset Correction: v_off_ini = 2629.738 uV, v_off_fin = 2603.919 uV 12:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.098 uVs 12:44:00 Integrated Voltage Measurement... 12:44:09 Voltage Offset Correction: v_off_ini = 2614.720 uV, v_off_fin = 2618.448 uV 12:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.808 uVs 12:44:13 I1Y Average and RMS of Measurements VT = -215.264 +- 4.815 uVs I1Y = -43.054 +- 0.961 uTm 12:44:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:44:21 Integrated Voltage Measurement... 12:44:30 Voltage Offset Correction: v_off_ini = 2589.799 uV, v_off_fin = 2599.056 uV 12:44:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.162 uVs 12:44:30 Integrated Voltage Measurement... 12:44:39 Voltage Offset Correction: v_off_ini = 2601.322 uV, v_off_fin = 2626.542 uV 12:44:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.629 uVs 12:44:39 Integrated Voltage Measurement... 12:44:48 Voltage Offset Correction: v_off_ini = 2625.989 uV, v_off_fin = 2626.397 uV 12:44:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.290 uVs 12:44:48 Integrated Voltage Measurement... 12:44:57 Voltage Offset Correction: v_off_ini = 2621.220 uV, v_off_fin = 2629.803 uV 12:44:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.622 uVs 12:44:57 Integrated Voltage Measurement... 12:45:06 Voltage Offset Correction: v_off_ini = 2605.665 uV, v_off_fin = 2620.368 uV 12:45:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -149.155 uVs 12:45:06 Integrated Voltage Measurement... 12:45:15 Voltage Offset Correction: v_off_ini = 2600.521 uV, v_off_fin = 2614.876 uV 12:45:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.214 uVs 12:45:17 I2X Average and RMS of Measurements VT = -103.179 +- 15.460 uVs I2X = 9.493 +- 1.422 uTm^2 12:45:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:45:25 Integrated Voltage Measurement... 12:45:34 Voltage Offset Correction: v_off_ini = 2583.885 uV, v_off_fin = 2580.174 uV 12:45:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.219 uVs 12:45:34 Integrated Voltage Measurement... 12:45:43 Voltage Offset Correction: v_off_ini = 2565.086 uV, v_off_fin = 2591.889 uV 12:45:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.399 uVs 12:45:43 Integrated Voltage Measurement... 12:45:52 Voltage Offset Correction: v_off_ini = 2592.103 uV, v_off_fin = 2576.009 uV 12:45:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -368.851 uVs 12:45:52 Integrated Voltage Measurement... 12:46:01 Voltage Offset Correction: v_off_ini = 2598.127 uV, v_off_fin = 2582.979 uV 12:46:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.101 uVs 12:46:01 Integrated Voltage Measurement... 12:46:10 Voltage Offset Correction: v_off_ini = 2608.028 uV, v_off_fin = 2608.335 uV 12:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.346 uVs 12:46:10 Integrated Voltage Measurement... 12:46:19 Voltage Offset Correction: v_off_ini = 2583.495 uV, v_off_fin = 2594.578 uV 12:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 377.737 uVs 12:46:22 I2Y Average and RMS of Measurements VT = -354.609 +- 10.855 uVs I2Y = -32.624 +- 0.999 uTm^2 12:46:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:30 Integrated Voltage Measurement... 12:46:39 Voltage Offset Correction: v_off_ini = 2573.693 uV, v_off_fin = 2560.494 uV 12:46:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.295 uVs 12:46:40 Integrated Voltage Measurement... 12:46:48 Voltage Offset Correction: v_off_ini = 2571.880 uV, v_off_fin = 2583.608 uV 12:46:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.528 uVs 12:46:49 Integrated Voltage Measurement... 12:46:57 Voltage Offset Correction: v_off_ini = 2585.410 uV, v_off_fin = 2588.605 uV 12:46:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.855 uVs 12:46:58 Integrated Voltage Measurement... 12:47:06 Voltage Offset Correction: v_off_ini = 2608.269 uV, v_off_fin = 2619.460 uV 12:47:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.097 uVs 12:47:07 Integrated Voltage Measurement... 12:47:15 Voltage Offset Correction: v_off_ini = 2612.073 uV, v_off_fin = 2603.754 uV 12:47:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.406 uVs 12:47:16 Integrated Voltage Measurement... 12:47:25 Voltage Offset Correction: v_off_ini = 2583.452 uV, v_off_fin = 2604.760 uV 12:47:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.157 uVs 12:47:29 I1X Average and RMS of Measurements VT = -71.890 +- 10.425 uVs I1X = 14.378 +- 2.085 uTm 12:47:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:36 Integrated Voltage Measurement... 12:47:44 Voltage Offset Correction: v_off_ini = 2596.335 uV, v_off_fin = 2588.493 uV 12:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.570 uVs 12:47:44 Integrated Voltage Measurement... 12:47:53 Voltage Offset Correction: v_off_ini = 2590.942 uV, v_off_fin = 2586.128 uV 12:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.023 uVs 12:47:54 Integrated Voltage Measurement... 12:48:02 Voltage Offset Correction: v_off_ini = 2568.462 uV, v_off_fin = 2549.820 uV 12:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.975 uVs 12:48:03 Integrated Voltage Measurement... 12:48:11 Voltage Offset Correction: v_off_ini = 2561.389 uV, v_off_fin = 2588.498 uV 12:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.696 uVs 12:48:12 Integrated Voltage Measurement... 12:48:20 Voltage Offset Correction: v_off_ini = 2576.011 uV, v_off_fin = 2555.807 uV 12:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.942 uVs 12:48:20 Integrated Voltage Measurement... 12:48:29 Voltage Offset Correction: v_off_ini = 2548.472 uV, v_off_fin = 2544.251 uV 12:48:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.545 uVs 12:48:34 I1Y Average and RMS of Measurements VT = -214.625 +- 13.932 uVs I1Y = -42.925 +- 2.786 uTm 12:48:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:41 Integrated Voltage Measurement... 12:48:50 Voltage Offset Correction: v_off_ini = 2567.418 uV, v_off_fin = 2551.482 uV 12:48:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.853 uVs 12:48:50 Integrated Voltage Measurement... 12:48:59 Voltage Offset Correction: v_off_ini = 2568.307 uV, v_off_fin = 2588.000 uV 12:48:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.953 uVs 12:48:59 Integrated Voltage Measurement... 12:49:08 Voltage Offset Correction: v_off_ini = 2571.143 uV, v_off_fin = 2553.220 uV 12:49:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.913 uVs 12:49:08 Integrated Voltage Measurement... 12:49:17 Voltage Offset Correction: v_off_ini = 2561.286 uV, v_off_fin = 2563.743 uV 12:49:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.109 uVs 12:49:17 Integrated Voltage Measurement... 12:49:26 Voltage Offset Correction: v_off_ini = 2533.994 uV, v_off_fin = 2529.366 uV 12:49:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -73.475 uVs 12:49:26 Integrated Voltage Measurement... 12:49:35 Voltage Offset Correction: v_off_ini = 2577.248 uV, v_off_fin = 2586.610 uV 12:49:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.803 uVs 12:49:38 I2X Average and RMS of Measurements VT = -67.184 +- 1.261 uVs I2X = 6.181 +- 0.116 uTm^2 12:49:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:49:46 Integrated Voltage Measurement... 12:49:55 Voltage Offset Correction: v_off_ini = 2565.521 uV, v_off_fin = 2567.410 uV 12:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.781 uVs 12:49:55 Integrated Voltage Measurement... 12:50:04 Voltage Offset Correction: v_off_ini = 2555.180 uV, v_off_fin = 2552.231 uV 12:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.535 uVs 12:50:04 Integrated Voltage Measurement... 12:50:13 Voltage Offset Correction: v_off_ini = 2570.019 uV, v_off_fin = 2571.701 uV 12:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -377.854 uVs 12:50:13 Integrated Voltage Measurement... 12:50:22 Voltage Offset Correction: v_off_ini = 2563.404 uV, v_off_fin = 2572.785 uV 12:50:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.875 uVs 12:50:22 Integrated Voltage Measurement... 12:50:31 Voltage Offset Correction: v_off_ini = 2565.961 uV, v_off_fin = 2588.631 uV 12:50:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.994 uVs 12:50:31 Integrated Voltage Measurement... 12:50:40 Voltage Offset Correction: v_off_ini = 2601.237 uV, v_off_fin = 2584.823 uV 12:50:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 382.104 uVs 12:50:42 I2Y Average and RMS of Measurements VT = -364.357 +- 10.576 uVs I2Y = -33.521 +- 0.973 uTm^2 12:50:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:50:51 Integrated Voltage Measurement... 12:51:00 Voltage Offset Correction: v_off_ini = 2596.122 uV, v_off_fin = 2556.422 uV 12:51:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.660 uVs 12:51:00 Integrated Voltage Measurement... 12:51:09 Voltage Offset Correction: v_off_ini = 2586.200 uV, v_off_fin = 2590.268 uV 12:51:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.934 uVs 12:51:09 Integrated Voltage Measurement... 12:51:18 Voltage Offset Correction: v_off_ini = 2576.219 uV, v_off_fin = 2581.040 uV 12:51:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.739 uVs 12:51:18 Integrated Voltage Measurement... 12:51:27 Voltage Offset Correction: v_off_ini = 2569.997 uV, v_off_fin = 2578.946 uV 12:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.908 uVs 12:51:27 Integrated Voltage Measurement... 12:51:36 Voltage Offset Correction: v_off_ini = 2556.324 uV, v_off_fin = 2539.833 uV 12:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.968 uVs 12:51:36 Integrated Voltage Measurement... 12:51:45 Voltage Offset Correction: v_off_ini = 2540.166 uV, v_off_fin = 2561.128 uV 12:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.076 uVs 12:51:49 I1X Average and RMS of Measurements VT = -70.881 +- 3.264 uVs I1X = 14.176 +- 0.653 uTm 12:51:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:51:56 Integrated Voltage Measurement... 12:52:05 Voltage Offset Correction: v_off_ini = 2580.089 uV, v_off_fin = 2550.463 uV 12:52:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.253 uVs 12:52:05 Integrated Voltage Measurement... 12:52:14 Voltage Offset Correction: v_off_ini = 2562.526 uV, v_off_fin = 2566.142 uV 12:52:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.221 uVs 12:52:14 Integrated Voltage Measurement... 12:52:23 Voltage Offset Correction: v_off_ini = 2557.937 uV, v_off_fin = 2559.133 uV 12:52:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.394 uVs 12:52:23 Integrated Voltage Measurement... 12:52:32 Voltage Offset Correction: v_off_ini = 2562.914 uV, v_off_fin = 2559.954 uV 12:52:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.836 uVs 12:52:32 Integrated Voltage Measurement... 12:52:41 Voltage Offset Correction: v_off_ini = 2541.256 uV, v_off_fin = 2530.518 uV 12:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.954 uVs 12:52:41 Integrated Voltage Measurement... 12:52:50 Voltage Offset Correction: v_off_ini = 2546.121 uV, v_off_fin = 2547.055 uV 12:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.022 uVs 12:52:54 I1Y Average and RMS of Measurements VT = -217.447 +- 3.744 uVs I1Y = -43.489 +- 0.749 uTm 12:52:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:53:02 Integrated Voltage Measurement... 12:53:11 Voltage Offset Correction: v_off_ini = 2542.576 uV, v_off_fin = 2524.516 uV 12:53:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -29.806 uVs 12:53:11 Integrated Voltage Measurement... 12:53:20 Voltage Offset Correction: v_off_ini = 2533.154 uV, v_off_fin = 2546.506 uV 12:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.816 uVs 12:53:20 Integrated Voltage Measurement... 12:53:29 Voltage Offset Correction: v_off_ini = 2541.889 uV, v_off_fin = 2561.254 uV 12:53:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.135 uVs 12:53:29 Integrated Voltage Measurement... 12:53:38 Voltage Offset Correction: v_off_ini = 2540.800 uV, v_off_fin = 2567.263 uV 12:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.569 uVs 12:53:38 Integrated Voltage Measurement... 12:53:47 Voltage Offset Correction: v_off_ini = 2531.377 uV, v_off_fin = 2518.328 uV 12:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.289 uVs 12:53:47 Integrated Voltage Measurement... 12:53:56 Voltage Offset Correction: v_off_ini = 2571.128 uV, v_off_fin = 2566.200 uV 12:53:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.360 uVs 12:53:58 I2X Average and RMS of Measurements VT = -44.329 +- 6.393 uVs I2X = 4.078 +- 0.588 uTm^2 12:54:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:54:06 Integrated Voltage Measurement... 12:54:15 Voltage Offset Correction: v_off_ini = 2548.609 uV, v_off_fin = 2534.287 uV 12:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -356.861 uVs 12:54:15 Integrated Voltage Measurement... 12:54:24 Voltage Offset Correction: v_off_ini = 2558.292 uV, v_off_fin = 2548.244 uV 12:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.091 uVs 12:54:24 Integrated Voltage Measurement... 12:54:33 Voltage Offset Correction: v_off_ini = 2537.863 uV, v_off_fin = 2519.727 uV 12:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.894 uVs 12:54:33 Integrated Voltage Measurement... 12:54:42 Voltage Offset Correction: v_off_ini = 2531.026 uV, v_off_fin = 2539.117 uV 12:54:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.979 uVs 12:54:42 Integrated Voltage Measurement... 12:54:51 Voltage Offset Correction: v_off_ini = 2537.470 uV, v_off_fin = 2528.606 uV 12:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.179 uVs 12:54:51 Integrated Voltage Measurement... 12:55:00 Voltage Offset Correction: v_off_ini = 2537.393 uV, v_off_fin = 2528.226 uV 12:55:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.486 uVs 12:55:03 I2Y Average and RMS of Measurements VT = -348.748 +- 5.496 uVs I2Y = -32.085 +- 0.506 uTm^2 12:55:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:55:11 Integrated Voltage Measurement... 12:55:20 Voltage Offset Correction: v_off_ini = 2561.394 uV, v_off_fin = 2554.409 uV 12:55:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.247 uVs 12:55:20 Integrated Voltage Measurement... 12:55:29 Voltage Offset Correction: v_off_ini = 2572.688 uV, v_off_fin = 2571.188 uV 12:55:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.921 uVs 12:55:29 Integrated Voltage Measurement... 12:55:38 Voltage Offset Correction: v_off_ini = 2568.809 uV, v_off_fin = 2559.749 uV 12:55:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.117 uVs 12:55:38 Integrated Voltage Measurement... 12:55:47 Voltage Offset Correction: v_off_ini = 2576.575 uV, v_off_fin = 2570.914 uV 12:55:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.110 uVs 12:55:47 Integrated Voltage Measurement... 12:55:56 Voltage Offset Correction: v_off_ini = 2544.883 uV, v_off_fin = 2555.262 uV 12:55:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.407 uVs 12:55:56 Integrated Voltage Measurement... 12:56:05 Voltage Offset Correction: v_off_ini = 2547.564 uV, v_off_fin = 2562.712 uV 12:56:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.230 uVs 12:56:10 I1X Average and RMS of Measurements VT = -50.339 +- 5.714 uVs I1X = 10.068 +- 1.143 uTm 12:56:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:56:16 Integrated Voltage Measurement... 12:56:25 Voltage Offset Correction: v_off_ini = 2536.606 uV, v_off_fin = 2519.283 uV 12:56:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -217.453 uVs 12:56:25 Integrated Voltage Measurement... 12:56:34 Voltage Offset Correction: v_off_ini = 2519.042 uV, v_off_fin = 2523.333 uV 12:56:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.409 uVs 12:56:34 Integrated Voltage Measurement... 12:56:43 Voltage Offset Correction: v_off_ini = 2543.383 uV, v_off_fin = 2543.044 uV 12:56:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.596 uVs 12:56:43 Integrated Voltage Measurement... 12:56:52 Voltage Offset Correction: v_off_ini = 2523.579 uV, v_off_fin = 2559.808 uV 12:56:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.357 uVs 12:56:52 Integrated Voltage Measurement... 12:57:01 Voltage Offset Correction: v_off_ini = 2556.973 uV, v_off_fin = 2560.877 uV 12:57:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.788 uVs 12:57:01 Integrated Voltage Measurement... 12:57:10 Voltage Offset Correction: v_off_ini = 2567.554 uV, v_off_fin = 2564.310 uV 12:57:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.924 uVs 12:57:15 I1Y Average and RMS of Measurements VT = -235.588 +- 7.998 uVs I1Y = -47.118 +- 1.599 uTm 12:57:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:57:22 Integrated Voltage Measurement... 12:57:31 Voltage Offset Correction: v_off_ini = 2546.986 uV, v_off_fin = 2529.954 uV 12:57:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -49.643 uVs 12:57:31 Integrated Voltage Measurement... 12:57:40 Voltage Offset Correction: v_off_ini = 2524.535 uV, v_off_fin = 2537.700 uV 12:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.008 uVs 12:57:40 Integrated Voltage Measurement... 12:57:49 Voltage Offset Correction: v_off_ini = 2545.489 uV, v_off_fin = 2520.137 uV 12:57:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.012 uVs 12:57:49 Integrated Voltage Measurement... 12:57:58 Voltage Offset Correction: v_off_ini = 2507.416 uV, v_off_fin = 2512.843 uV 12:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.682 uVs 12:57:58 Integrated Voltage Measurement... 12:58:07 Voltage Offset Correction: v_off_ini = 2483.221 uV, v_off_fin = 2471.394 uV 12:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.514 uVs 12:58:07 Integrated Voltage Measurement... 12:58:16 Voltage Offset Correction: v_off_ini = 2474.588 uV, v_off_fin = 2509.023 uV 12:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.857 uVs 12:58:19 I2X Average and RMS of Measurements VT = -37.117 +- 12.606 uVs I2X = 3.415 +- 1.160 uTm^2 12:58:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:58:27 Integrated Voltage Measurement... 12:58:35 Voltage Offset Correction: v_off_ini = 2545.964 uV, v_off_fin = 2532.785 uV 12:58:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -394.644 uVs 12:58:36 Integrated Voltage Measurement... 12:58:45 Voltage Offset Correction: v_off_ini = 2508.694 uV, v_off_fin = 2521.669 uV 12:58:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.870 uVs 12:58:45 Integrated Voltage Measurement... 12:58:54 Voltage Offset Correction: v_off_ini = 2534.122 uV, v_off_fin = 2533.623 uV 12:58:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -389.689 uVs 12:58:54 Integrated Voltage Measurement... 12:59:03 Voltage Offset Correction: v_off_ini = 2534.330 uV, v_off_fin = 2537.078 uV 12:59:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.239 uVs 12:59:03 Integrated Voltage Measurement... 12:59:12 Voltage Offset Correction: v_off_ini = 2507.323 uV, v_off_fin = 2525.967 uV 12:59:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.860 uVs 12:59:12 Integrated Voltage Measurement... 12:59:21 Voltage Offset Correction: v_off_ini = 2499.521 uV, v_off_fin = 2505.454 uV 12:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.975 uVs 12:59:23 I2Y Average and RMS of Measurements VT = -365.546 +- 7.779 uVs I2Y = -33.630 +- 0.716 uTm^2 12:59:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:59:35 Integrated Voltage Measurement... 12:59:44 Voltage Offset Correction: v_off_ini = 2498.446 uV, v_off_fin = 2516.028 uV 12:59:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.537 uVs 12:59:44 Integrated Voltage Measurement... 12:59:53 Voltage Offset Correction: v_off_ini = 2499.319 uV, v_off_fin = 2500.616 uV 12:59:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.228 uVs 12:59:53 Integrated Voltage Measurement... 13:00:02 Voltage Offset Correction: v_off_ini = 2485.289 uV, v_off_fin = 2502.783 uV 13:00:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.665 uVs 13:00:02 Integrated Voltage Measurement... 13:00:11 Voltage Offset Correction: v_off_ini = 2497.891 uV, v_off_fin = 2500.191 uV 13:00:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.901 uVs 13:00:11 Integrated Voltage Measurement... 13:00:20 Voltage Offset Correction: v_off_ini = 2494.893 uV, v_off_fin = 2525.544 uV 13:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.474 uVs 13:00:20 Integrated Voltage Measurement... 13:00:29 Voltage Offset Correction: v_off_ini = 2523.436 uV, v_off_fin = 2523.933 uV 13:00:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.043 uVs 13:00:33 I1X Average and RMS of Measurements VT = -60.475 +- 10.825 uVs I1X = 12.095 +- 2.165 uTm 13:00:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:00:40 Integrated Voltage Measurement... 13:00:49 Voltage Offset Correction: v_off_ini = 2511.593 uV, v_off_fin = 2497.304 uV 13:00:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.985 uVs 13:00:49 Integrated Voltage Measurement... 13:00:58 Voltage Offset Correction: v_off_ini = 2498.693 uV, v_off_fin = 2501.685 uV 13:00:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.265 uVs 13:00:58 Integrated Voltage Measurement... 13:01:07 Voltage Offset Correction: v_off_ini = 2492.696 uV, v_off_fin = 2486.482 uV 13:01:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.920 uVs 13:01:07 Integrated Voltage Measurement... 13:01:16 Voltage Offset Correction: v_off_ini = 2464.065 uV, v_off_fin = 2489.973 uV 13:01:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.981 uVs 13:01:16 Integrated Voltage Measurement... 13:01:25 Voltage Offset Correction: v_off_ini = 2476.742 uV, v_off_fin = 2464.126 uV 13:01:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.318 uVs 13:01:25 Integrated Voltage Measurement... 13:01:34 Voltage Offset Correction: v_off_ini = 2475.888 uV, v_off_fin = 2482.970 uV 13:01:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.115 uVs 13:01:38 I1Y Average and RMS of Measurements VT = -227.931 +- 1.974 uVs I1Y = -45.586 +- 0.395 uTm 13:01:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:01:43 Integrated Voltage Measurement... 13:01:52 Voltage Offset Correction: v_off_ini = 2467.309 uV, v_off_fin = 2475.473 uV 13:01:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -66.477 uVs 13:01:52 Integrated Voltage Measurement... 13:02:01 Voltage Offset Correction: v_off_ini = 2510.162 uV, v_off_fin = 2514.024 uV 13:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.406 uVs 13:02:01 Integrated Voltage Measurement... 13:02:10 Voltage Offset Correction: v_off_ini = 2501.204 uV, v_off_fin = 2498.086 uV 13:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.462 uVs 13:02:10 Integrated Voltage Measurement... 13:02:19 Voltage Offset Correction: v_off_ini = 2522.255 uV, v_off_fin = 2520.639 uV 13:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.933 uVs 13:02:19 Integrated Voltage Measurement... 13:02:28 Voltage Offset Correction: v_off_ini = 2497.704 uV, v_off_fin = 2494.160 uV 13:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.937 uVs 13:02:28 Integrated Voltage Measurement... 13:02:37 Voltage Offset Correction: v_off_ini = 2501.745 uV, v_off_fin = 2490.436 uV 13:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.715 uVs 13:02:40 I2X Average and RMS of Measurements VT = -76.655 +- 3.648 uVs I2X = 7.052 +- 0.336 uTm^2 13:02:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:02:45 Integrated Voltage Measurement... 13:02:54 Voltage Offset Correction: v_off_ini = 2462.856 uV, v_off_fin = 2449.659 uV 13:02:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -390.771 uVs 13:02:54 Integrated Voltage Measurement... 13:03:03 Voltage Offset Correction: v_off_ini = 2454.719 uV, v_off_fin = 2462.868 uV 13:03:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.580 uVs 13:03:03 Integrated Voltage Measurement... 13:03:12 Voltage Offset Correction: v_off_ini = 2475.221 uV, v_off_fin = 2462.690 uV 13:03:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -397.574 uVs 13:03:12 Integrated Voltage Measurement... 13:03:21 Voltage Offset Correction: v_off_ini = 2467.541 uV, v_off_fin = 2468.561 uV 13:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 374.509 uVs 13:03:21 Integrated Voltage Measurement... 13:03:30 Voltage Offset Correction: v_off_ini = 2462.149 uV, v_off_fin = 2446.007 uV 13:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.063 uVs 13:03:30 Integrated Voltage Measurement... 13:03:39 Voltage Offset Correction: v_off_ini = 2482.868 uV, v_off_fin = 2475.279 uV 13:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 371.805 uVs 13:03:41 I2Y Average and RMS of Measurements VT = -376.550 +- 10.488 uVs I2Y = -34.643 +- 0.965 uTm^2 13:03:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:03:50 Integrated Voltage Measurement... 13:03:59 Voltage Offset Correction: v_off_ini = 2453.345 uV, v_off_fin = 2442.226 uV 13:03:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -81.546 uVs 13:03:59 Integrated Voltage Measurement... 13:04:08 Voltage Offset Correction: v_off_ini = 2464.901 uV, v_off_fin = 2463.761 uV 13:04:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.885 uVs 13:04:08 Integrated Voltage Measurement... 13:04:17 Voltage Offset Correction: v_off_ini = 2442.079 uV, v_off_fin = 2427.338 uV 13:04:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.173 uVs 13:04:17 Integrated Voltage Measurement... 13:04:26 Voltage Offset Correction: v_off_ini = 2436.581 uV, v_off_fin = 2445.158 uV 13:04:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.135 uVs 13:04:26 Integrated Voltage Measurement... 13:04:35 Voltage Offset Correction: v_off_ini = 2439.470 uV, v_off_fin = 2417.792 uV 13:04:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.369 uVs 13:04:35 Integrated Voltage Measurement... 13:04:44 Voltage Offset Correction: v_off_ini = 2430.317 uV, v_off_fin = 2424.765 uV 13:04:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.910 uVs 13:04:48 I1X Average and RMS of Measurements VT = -64.836 +- 3.996 uVs I1X = 12.968 +- 0.798 uTm 13:04:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:04:55 Integrated Voltage Measurement... 13:05:04 Voltage Offset Correction: v_off_ini = 2431.771 uV, v_off_fin = 2408.058 uV 13:05:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -228.239 uVs 13:05:04 Integrated Voltage Measurement... 13:05:13 Voltage Offset Correction: v_off_ini = 2390.949 uV, v_off_fin = 2389.562 uV 13:05:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.142 uVs 13:05:13 Integrated Voltage Measurement... 13:05:22 Voltage Offset Correction: v_off_ini = 2410.776 uV, v_off_fin = 2390.740 uV 13:05:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.835 uVs 13:05:22 Integrated Voltage Measurement... 13:05:31 Voltage Offset Correction: v_off_ini = 2410.363 uV, v_off_fin = 2417.324 uV 13:05:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.499 uVs 13:05:31 Integrated Voltage Measurement... 13:05:40 Voltage Offset Correction: v_off_ini = 2406.040 uV, v_off_fin = 2389.607 uV 13:05:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.977 uVs 13:05:40 Integrated Voltage Measurement... 13:05:49 Voltage Offset Correction: v_off_ini = 2409.970 uV, v_off_fin = 2449.337 uV 13:05:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.587 uVs 13:05:53 I1Y Average and RMS of Measurements VT = -229.047 +- 5.067 uVs I1Y = -45.810 +- 1.013 uTm 13:05:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:05:58 Integrated Voltage Measurement... 13:06:07 Voltage Offset Correction: v_off_ini = 2424.713 uV, v_off_fin = 2446.130 uV 13:06:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.537 uVs 13:06:07 Integrated Voltage Measurement... 13:06:16 Voltage Offset Correction: v_off_ini = 2463.470 uV, v_off_fin = 2457.034 uV 13:06:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.065 uVs 13:06:16 Integrated Voltage Measurement... 13:06:25 Voltage Offset Correction: v_off_ini = 2454.291 uV, v_off_fin = 2457.056 uV 13:06:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.581 uVs 13:06:25 Integrated Voltage Measurement... 13:06:34 Voltage Offset Correction: v_off_ini = 2474.325 uV, v_off_fin = 2470.524 uV 13:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.214 uVs 13:06:34 Integrated Voltage Measurement... 13:06:43 Voltage Offset Correction: v_off_ini = 2458.148 uV, v_off_fin = 2462.289 uV 13:06:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.846 uVs 13:06:43 Integrated Voltage Measurement... 13:06:52 Voltage Offset Correction: v_off_ini = 2458.692 uV, v_off_fin = 2442.537 uV 13:06:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.785 uVs 13:06:55 I2X Average and RMS of Measurements VT = -81.338 +- 8.136 uVs I2X = 7.483 +- 0.748 uTm^2 13:06:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:07:00 Integrated Voltage Measurement... 13:07:09 Voltage Offset Correction: v_off_ini = 2483.165 uV, v_off_fin = 2475.293 uV 13:07:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -374.532 uVs 13:07:09 Integrated Voltage Measurement... 13:07:18 Voltage Offset Correction: v_off_ini = 2482.452 uV, v_off_fin = 2473.759 uV 13:07:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 359.458 uVs 13:07:18 Integrated Voltage Measurement... 13:07:27 Voltage Offset Correction: v_off_ini = 2494.983 uV, v_off_fin = 2433.620 uV 13:07:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.682 uVs 13:07:27 Integrated Voltage Measurement... 13:07:36 Voltage Offset Correction: v_off_ini = 2478.528 uV, v_off_fin = 2473.479 uV 13:07:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 363.036 uVs 13:07:36 Integrated Voltage Measurement... 13:07:45 Voltage Offset Correction: v_off_ini = 2479.500 uV, v_off_fin = 2466.534 uV 13:07:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -384.232 uVs 13:07:45 Integrated Voltage Measurement... 13:07:54 Voltage Offset Correction: v_off_ini = 2445.519 uV, v_off_fin = 2469.009 uV 13:07:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 370.990 uVs 13:07:56 I2Y Average and RMS of Measurements VT = -363.155 +- 13.644 uVs I2Y = -33.410 +- 1.255 uTm^2 13:08:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:05 Integrated Voltage Measurement... 13:08:14 Voltage Offset Correction: v_off_ini = 2464.189 uV, v_off_fin = 2481.823 uV 13:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -47.696 uVs 13:08:14 Integrated Voltage Measurement... 13:08:23 Voltage Offset Correction: v_off_ini = 2455.515 uV, v_off_fin = 2476.062 uV 13:08:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.705 uVs 13:08:23 Integrated Voltage Measurement... 13:08:32 Voltage Offset Correction: v_off_ini = 2458.108 uV, v_off_fin = 2486.867 uV 13:08:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.208 uVs 13:08:32 Integrated Voltage Measurement... 13:08:41 Voltage Offset Correction: v_off_ini = 2524.627 uV, v_off_fin = 2513.137 uV 13:08:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.653 uVs 13:08:41 Integrated Voltage Measurement... 13:08:50 Voltage Offset Correction: v_off_ini = 2463.892 uV, v_off_fin = 2471.227 uV 13:08:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.530 uVs 13:08:50 Integrated Voltage Measurement... 13:08:59 Voltage Offset Correction: v_off_ini = 2491.201 uV, v_off_fin = 2488.830 uV 13:08:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.971 uVs 13:09:03 I1X Average and RMS of Measurements VT = -62.127 +- 6.471 uVs I1X = 12.426 +- 1.294 uTm 13:09:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:09:10 Integrated Voltage Measurement... 13:09:18 Voltage Offset Correction: v_off_ini = 2487.196 uV, v_off_fin = 2495.426 uV 13:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.873 uVs 13:09:19 Integrated Voltage Measurement... 13:09:27 Voltage Offset Correction: v_off_ini = 2490.456 uV, v_off_fin = 2484.708 uV 13:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.033 uVs 13:09:28 Integrated Voltage Measurement... 13:09:36 Voltage Offset Correction: v_off_ini = 2513.935 uV, v_off_fin = 2478.159 uV 13:09:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.164 uVs 13:09:37 Integrated Voltage Measurement... 13:09:45 Voltage Offset Correction: v_off_ini = 2467.529 uV, v_off_fin = 2470.884 uV 13:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.166 uVs 13:09:46 Integrated Voltage Measurement... 13:09:54 Voltage Offset Correction: v_off_ini = 2476.719 uV, v_off_fin = 2466.842 uV 13:09:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.667 uVs 13:09:55 Integrated Voltage Measurement... 13:10:03 Voltage Offset Correction: v_off_ini = 2451.088 uV, v_off_fin = 2464.239 uV 13:10:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.833 uVs 13:10:08 I1Y Average and RMS of Measurements VT = -225.956 +- 3.369 uVs I1Y = -45.191 +- 0.674 uTm 13:10:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:10:13 Integrated Voltage Measurement... 13:10:22 Voltage Offset Correction: v_off_ini = 2445.777 uV, v_off_fin = 2466.526 uV 13:10:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.691 uVs 13:10:22 Integrated Voltage Measurement... 13:10:31 Voltage Offset Correction: v_off_ini = 2487.990 uV, v_off_fin = 2465.496 uV 13:10:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.066 uVs 13:10:31 Integrated Voltage Measurement... 13:10:40 Voltage Offset Correction: v_off_ini = 2427.521 uV, v_off_fin = 2441.027 uV 13:10:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.532 uVs 13:10:40 Integrated Voltage Measurement... 13:10:49 Voltage Offset Correction: v_off_ini = 2449.320 uV, v_off_fin = 2461.148 uV 13:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.272 uVs 13:10:49 Integrated Voltage Measurement... 13:10:58 Voltage Offset Correction: v_off_ini = 2445.417 uV, v_off_fin = 2444.165 uV 13:10:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.440 uVs 13:10:58 Integrated Voltage Measurement... 13:11:07 Voltage Offset Correction: v_off_ini = 2457.457 uV, v_off_fin = 2457.225 uV 13:11:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.235 uVs 13:11:09 I2X Average and RMS of Measurements VT = -57.373 +- 12.780 uVs I2X = 5.278 +- 1.176 uTm^2 13:11:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:14 Integrated Voltage Measurement... 13:11:23 Voltage Offset Correction: v_off_ini = 2428.507 uV, v_off_fin = 2430.066 uV 13:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.927 uVs 13:11:24 Integrated Voltage Measurement... 13:11:32 Voltage Offset Correction: v_off_ini = 2446.113 uV, v_off_fin = 2450.552 uV 13:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 368.029 uVs 13:11:33 Integrated Voltage Measurement... 13:11:42 Voltage Offset Correction: v_off_ini = 2466.805 uV, v_off_fin = 2432.610 uV 13:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.735 uVs 13:11:42 Integrated Voltage Measurement... 13:11:51 Voltage Offset Correction: v_off_ini = 2437.373 uV, v_off_fin = 2446.945 uV 13:11:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.104 uVs 13:11:51 Integrated Voltage Measurement... 13:12:00 Voltage Offset Correction: v_off_ini = 2438.618 uV, v_off_fin = 2461.477 uV 13:12:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.424 uVs 13:12:00 Integrated Voltage Measurement... 13:12:09 Voltage Offset Correction: v_off_ini = 2448.939 uV, v_off_fin = 2452.862 uV 13:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.202 uVs 13:12:11 I2Y Average and RMS of Measurements VT = -349.737 +- 1.966 uVs I2Y = -32.176 +- 0.181 uTm^2 13:12:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:12:19 Integrated Voltage Measurement... 13:12:28 Voltage Offset Correction: v_off_ini = 2446.788 uV, v_off_fin = 2449.320 uV 13:12:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -47.110 uVs 13:12:28 Integrated Voltage Measurement... 13:12:37 Voltage Offset Correction: v_off_ini = 2438.247 uV, v_off_fin = 2452.892 uV 13:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.939 uVs 13:12:37 Integrated Voltage Measurement... 13:12:46 Voltage Offset Correction: v_off_ini = 2439.637 uV, v_off_fin = 2425.895 uV 13:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.028 uVs 13:12:46 Integrated Voltage Measurement... 13:12:55 Voltage Offset Correction: v_off_ini = 2439.945 uV, v_off_fin = 2464.293 uV 13:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.916 uVs 13:12:55 Integrated Voltage Measurement... 13:13:04 Voltage Offset Correction: v_off_ini = 2463.347 uV, v_off_fin = 2440.205 uV 13:13:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.324 uVs 13:13:04 Integrated Voltage Measurement... 13:13:13 Voltage Offset Correction: v_off_ini = 2487.159 uV, v_off_fin = 2481.283 uV 13:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.773 uVs 13:13:18 I1X Average and RMS of Measurements VT = -52.515 +- 4.982 uVs I1X = 10.503 +- 0.996 uTm 13:13:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:13:24 Integrated Voltage Measurement... 13:13:33 Voltage Offset Correction: v_off_ini = 2435.712 uV, v_off_fin = 2443.382 uV 13:13:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -227.284 uVs 13:13:33 Integrated Voltage Measurement... 13:13:42 Voltage Offset Correction: v_off_ini = 2473.079 uV, v_off_fin = 2484.135 uV 13:13:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 202.499 uVs 13:13:42 Integrated Voltage Measurement... 13:13:51 Voltage Offset Correction: v_off_ini = 2467.590 uV, v_off_fin = 2468.958 uV 13:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.334 uVs 13:13:51 Integrated Voltage Measurement... 13:14:00 Voltage Offset Correction: v_off_ini = 2478.833 uV, v_off_fin = 2480.879 uV 13:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.054 uVs 13:14:00 Integrated Voltage Measurement... 13:14:09 Voltage Offset Correction: v_off_ini = 2505.120 uV, v_off_fin = 2479.215 uV 13:14:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.962 uVs 13:14:09 Integrated Voltage Measurement... 13:14:18 Voltage Offset Correction: v_off_ini = 2486.048 uV, v_off_fin = 2508.292 uV 13:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.056 uVs 13:14:22 I1Y Average and RMS of Measurements VT = -215.198 +- 1.117 uVs I1Y = -43.036 +- 0.223 uTm 13:14:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:14:28 Integrated Voltage Measurement... 13:14:37 Voltage Offset Correction: v_off_ini = 2488.986 uV, v_off_fin = 2466.111 uV 13:14:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.045 uVs 13:14:37 Integrated Voltage Measurement... 13:14:46 Voltage Offset Correction: v_off_ini = 2481.670 uV, v_off_fin = 2488.238 uV 13:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.418 uVs 13:14:46 Integrated Voltage Measurement... 13:14:55 Voltage Offset Correction: v_off_ini = 2487.564 uV, v_off_fin = 2452.390 uV 13:14:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.645 uVs 13:14:55 Integrated Voltage Measurement... 13:15:04 Voltage Offset Correction: v_off_ini = 2451.122 uV, v_off_fin = 2455.665 uV 13:15:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.515 uVs 13:15:04 Integrated Voltage Measurement... 13:15:13 Voltage Offset Correction: v_off_ini = 2459.723 uV, v_off_fin = 2438.920 uV 13:15:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.151 uVs 13:15:13 Integrated Voltage Measurement... 13:15:22 Voltage Offset Correction: v_off_ini = 2440.347 uV, v_off_fin = 2437.229 uV 13:15:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.320 uVs 13:15:24 I2X Average and RMS of Measurements VT = -67.682 +- 6.403 uVs I2X = 6.227 +- 0.589 uTm^2 13:15:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:15:29 Integrated Voltage Measurement... 13:15:38 Voltage Offset Correction: v_off_ini = 2429.463 uV, v_off_fin = 2418.738 uV 13:15:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.401 uVs 13:15:38 Integrated Voltage Measurement... 13:15:47 Voltage Offset Correction: v_off_ini = 2429.791 uV, v_off_fin = 2418.094 uV 13:15:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.955 uVs 13:15:47 Integrated Voltage Measurement... 13:15:56 Voltage Offset Correction: v_off_ini = 2412.389 uV, v_off_fin = 2415.740 uV 13:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.769 uVs 13:15:56 Integrated Voltage Measurement... 13:16:05 Voltage Offset Correction: v_off_ini = 2419.872 uV, v_off_fin = 2408.927 uV 13:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.101 uVs 13:16:05 Integrated Voltage Measurement... 13:16:14 Voltage Offset Correction: v_off_ini = 2433.934 uV, v_off_fin = 2404.268 uV 13:16:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -364.720 uVs 13:16:14 Integrated Voltage Measurement... 13:16:23 Voltage Offset Correction: v_off_ini = 2413.584 uV, v_off_fin = 2422.175 uV 13:16:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.652 uVs 13:16:26 I2Y Average and RMS of Measurements VT = -340.600 +- 15.090 uVs I2Y = -31.335 +- 1.388 uTm^2 13:16:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:16:34 Integrated Voltage Measurement... 13:16:43 Voltage Offset Correction: v_off_ini = 2420.021 uV, v_off_fin = 2410.040 uV 13:16:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.958 uVs 13:16:43 Integrated Voltage Measurement... 13:16:52 Voltage Offset Correction: v_off_ini = 2418.772 uV, v_off_fin = 2420.611 uV 13:16:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.743 uVs 13:16:52 Integrated Voltage Measurement... 13:17:01 Voltage Offset Correction: v_off_ini = 2416.244 uV, v_off_fin = 2385.083 uV 13:17:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.038 uVs 13:17:01 Integrated Voltage Measurement... 13:17:10 Voltage Offset Correction: v_off_ini = 2404.725 uV, v_off_fin = 2427.389 uV 13:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 69.672 uVs 13:17:10 Integrated Voltage Measurement... 13:17:19 Voltage Offset Correction: v_off_ini = 2414.901 uV, v_off_fin = 2392.627 uV 13:17:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.974 uVs 13:17:19 Integrated Voltage Measurement... 13:17:28 Voltage Offset Correction: v_off_ini = 2394.009 uV, v_off_fin = 2391.520 uV 13:17:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.321 uVs 13:17:32 I1X Average and RMS of Measurements VT = -62.118 +- 9.981 uVs I1X = 12.424 +- 1.996 uTm 13:17:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:17:39 Integrated Voltage Measurement... 13:17:48 Voltage Offset Correction: v_off_ini = 2425.443 uV, v_off_fin = 2418.476 uV 13:17:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.135 uVs 13:17:48 Integrated Voltage Measurement... 13:17:57 Voltage Offset Correction: v_off_ini = 2421.645 uV, v_off_fin = 2416.603 uV 13:17:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.029 uVs 13:17:57 Integrated Voltage Measurement... 13:18:06 Voltage Offset Correction: v_off_ini = 2418.717 uV, v_off_fin = 2383.981 uV 13:18:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.965 uVs 13:18:06 Integrated Voltage Measurement... 13:18:15 Voltage Offset Correction: v_off_ini = 2389.742 uV, v_off_fin = 2407.105 uV 13:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.266 uVs 13:18:15 Integrated Voltage Measurement... 13:18:24 Voltage Offset Correction: v_off_ini = 2454.775 uV, v_off_fin = 2410.241 uV 13:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.513 uVs 13:18:24 Integrated Voltage Measurement... 13:18:33 Voltage Offset Correction: v_off_ini = 2428.966 uV, v_off_fin = 2428.151 uV 13:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.766 uVs 13:18:37 I1Y Average and RMS of Measurements VT = -217.612 +- 3.105 uVs I1Y = -43.522 +- 0.621 uTm 13:18:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:18:42 Integrated Voltage Measurement... 13:18:51 Voltage Offset Correction: v_off_ini = 2445.130 uV, v_off_fin = 2433.149 uV 13:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.690 uVs 13:18:51 Integrated Voltage Measurement... 13:19:00 Voltage Offset Correction: v_off_ini = 2455.012 uV, v_off_fin = 2442.747 uV 13:19:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.785 uVs 13:19:00 Integrated Voltage Measurement... 13:19:09 Voltage Offset Correction: v_off_ini = 2438.278 uV, v_off_fin = 2435.598 uV 13:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.808 uVs 13:19:09 Integrated Voltage Measurement... 13:19:18 Voltage Offset Correction: v_off_ini = 2431.873 uV, v_off_fin = 2444.988 uV 13:19:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.552 uVs 13:19:18 Integrated Voltage Measurement... 13:19:27 Voltage Offset Correction: v_off_ini = 2436.006 uV, v_off_fin = 2424.331 uV 13:19:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.532 uVs 13:19:27 Integrated Voltage Measurement... 13:19:36 Voltage Offset Correction: v_off_ini = 2443.680 uV, v_off_fin = 2442.949 uV 13:19:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.526 uVs 13:19:39 I2X Average and RMS of Measurements VT = -56.482 +- 6.662 uVs I2X = 5.196 +- 0.613 uTm^2 13:19:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:19:44 Integrated Voltage Measurement... 13:19:53 Voltage Offset Correction: v_off_ini = 2412.722 uV, v_off_fin = 2412.720 uV 13:19:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.622 uVs 13:19:53 Integrated Voltage Measurement... 13:20:02 Voltage Offset Correction: v_off_ini = 2436.240 uV, v_off_fin = 2421.403 uV 13:20:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.095 uVs 13:20:02 Integrated Voltage Measurement... 13:20:11 Voltage Offset Correction: v_off_ini = 2427.562 uV, v_off_fin = 2407.777 uV 13:20:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.105 uVs 13:20:11 Integrated Voltage Measurement... 13:20:20 Voltage Offset Correction: v_off_ini = 2389.484 uV, v_off_fin = 2396.866 uV 13:20:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.687 uVs 13:20:20 Integrated Voltage Measurement... 13:20:29 Voltage Offset Correction: v_off_ini = 2399.409 uV, v_off_fin = 2408.134 uV 13:20:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -344.338 uVs 13:20:29 Integrated Voltage Measurement... 13:20:38 Voltage Offset Correction: v_off_ini = 2402.332 uV, v_off_fin = 2422.544 uV 13:20:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.453 uVs 13:20:40 I2Y Average and RMS of Measurements VT = -332.383 +- 13.290 uVs I2Y = -30.579 +- 1.223 uTm^2 13:20:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:21:02 Integrated Voltage Measurement... 13:21:11 Voltage Offset Correction: v_off_ini = 2402.147 uV, v_off_fin = 2413.797 uV 13:21:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.180 uVs 13:21:11 Integrated Voltage Measurement... 13:21:20 Voltage Offset Correction: v_off_ini = 2409.828 uV, v_off_fin = 2425.983 uV 13:21:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 82.910 uVs 13:21:20 Integrated Voltage Measurement... 13:21:29 Voltage Offset Correction: v_off_ini = 2418.503 uV, v_off_fin = 2432.667 uV 13:21:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.283 uVs 13:21:29 Integrated Voltage Measurement... 13:21:38 Voltage Offset Correction: v_off_ini = 2437.485 uV, v_off_fin = 2430.409 uV 13:21:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.069 uVs 13:21:38 Integrated Voltage Measurement... 13:21:47 Voltage Offset Correction: v_off_ini = 2456.425 uV, v_off_fin = 2448.484 uV 13:21:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.151 uVs 13:21:47 Integrated Voltage Measurement... 13:21:56 Voltage Offset Correction: v_off_ini = 2430.469 uV, v_off_fin = 2421.921 uV 13:21:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.482 uVs 13:22:00 I1X Average and RMS of Measurements VT = -92.013 +- 4.625 uVs I1X = 18.403 +- 0.925 uTm 13:22:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:22:07 Integrated Voltage Measurement... 13:22:16 Voltage Offset Correction: v_off_ini = 2403.317 uV, v_off_fin = 2413.237 uV 13:22:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.212 uVs 13:22:16 Integrated Voltage Measurement... 13:22:25 Voltage Offset Correction: v_off_ini = 2424.989 uV, v_off_fin = 2457.297 uV 13:22:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.681 uVs 13:22:25 Integrated Voltage Measurement... 13:22:34 Voltage Offset Correction: v_off_ini = 2428.497 uV, v_off_fin = 2413.691 uV 13:22:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.218 uVs 13:22:34 Integrated Voltage Measurement... 13:22:43 Voltage Offset Correction: v_off_ini = 2407.859 uV, v_off_fin = 2425.229 uV 13:22:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.741 uVs 13:22:43 Integrated Voltage Measurement... 13:22:52 Voltage Offset Correction: v_off_ini = 2424.889 uV, v_off_fin = 2414.532 uV 13:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.106 uVs 13:22:52 Integrated Voltage Measurement... 13:23:01 Voltage Offset Correction: v_off_ini = 2417.157 uV, v_off_fin = 2410.558 uV 13:23:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 215.403 uVs 13:23:05 I1Y Average and RMS of Measurements VT = -199.227 +- 5.005 uVs I1Y = -39.846 +- 1.002 uTm 13:23:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:23:13 Integrated Voltage Measurement... 13:23:21 Voltage Offset Correction: v_off_ini = 2413.499 uV, v_off_fin = 2406.990 uV 13:23:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.876 uVs 13:23:22 Integrated Voltage Measurement... 13:23:31 Voltage Offset Correction: v_off_ini = 2390.975 uV, v_off_fin = 2391.463 uV 13:23:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.700 uVs 13:23:31 Integrated Voltage Measurement... 13:23:40 Voltage Offset Correction: v_off_ini = 2404.126 uV, v_off_fin = 2393.916 uV 13:23:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.172 uVs 13:23:40 Integrated Voltage Measurement... 13:23:49 Voltage Offset Correction: v_off_ini = 2396.729 uV, v_off_fin = 2404.668 uV 13:23:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.237 uVs 13:23:49 Integrated Voltage Measurement... 13:23:58 Voltage Offset Correction: v_off_ini = 2399.991 uV, v_off_fin = 2397.427 uV 13:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.103 uVs 13:23:58 Integrated Voltage Measurement... 13:24:07 Voltage Offset Correction: v_off_ini = 2397.300 uV, v_off_fin = 2407.840 uV 13:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.741 uVs 13:24:09 I2X Average and RMS of Measurements VT = -108.638 +- 3.279 uVs I2X = 9.995 +- 0.302 uTm^2 13:24:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:24:17 Integrated Voltage Measurement... 13:24:26 Voltage Offset Correction: v_off_ini = 2445.521 uV, v_off_fin = 2435.396 uV 13:24:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.594 uVs 13:24:26 Integrated Voltage Measurement... 13:24:35 Voltage Offset Correction: v_off_ini = 2420.364 uV, v_off_fin = 2427.777 uV 13:24:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.794 uVs 13:24:35 Integrated Voltage Measurement... 13:24:44 Voltage Offset Correction: v_off_ini = 2420.751 uV, v_off_fin = 2439.676 uV 13:24:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.874 uVs 13:24:44 Integrated Voltage Measurement... 13:24:53 Voltage Offset Correction: v_off_ini = 2449.882 uV, v_off_fin = 2446.912 uV 13:24:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.850 uVs 13:24:53 Integrated Voltage Measurement... 13:25:02 Voltage Offset Correction: v_off_ini = 2416.526 uV, v_off_fin = 2404.849 uV 13:25:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.192 uVs 13:25:02 Integrated Voltage Measurement... 13:25:11 Voltage Offset Correction: v_off_ini = 2392.861 uV, v_off_fin = 2442.427 uV 13:25:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.717 uVs 13:25:13 I2Y Average and RMS of Measurements VT = -310.003 +- 4.822 uVs I2Y = -28.520 +- 0.444 uTm^2 13:25:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:25:22 Integrated Voltage Measurement... 13:25:31 Voltage Offset Correction: v_off_ini = 2439.258 uV, v_off_fin = 2440.672 uV 13:25:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.656 uVs 13:25:31 Integrated Voltage Measurement... 13:25:40 Voltage Offset Correction: v_off_ini = 2430.926 uV, v_off_fin = 2427.117 uV 13:25:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.214 uVs 13:25:40 Integrated Voltage Measurement... 13:25:49 Voltage Offset Correction: v_off_ini = 2432.918 uV, v_off_fin = 2425.977 uV 13:25:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.572 uVs 13:25:49 Integrated Voltage Measurement... 13:25:58 Voltage Offset Correction: v_off_ini = 2424.119 uV, v_off_fin = 2418.119 uV 13:25:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.676 uVs 13:25:58 Integrated Voltage Measurement... 13:26:07 Voltage Offset Correction: v_off_ini = 2418.985 uV, v_off_fin = 2410.864 uV 13:26:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.930 uVs 13:26:07 Integrated Voltage Measurement... 13:26:16 Voltage Offset Correction: v_off_ini = 2411.948 uV, v_off_fin = 2398.342 uV 13:26:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.048 uVs 13:26:20 I1X Average and RMS of Measurements VT = -92.849 +- 8.796 uVs I1X = 18.570 +- 1.759 uTm 13:26:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:26:27 Integrated Voltage Measurement... 13:26:36 Voltage Offset Correction: v_off_ini = 2407.871 uV, v_off_fin = 2411.371 uV 13:26:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.754 uVs 13:26:36 Integrated Voltage Measurement... 13:26:45 Voltage Offset Correction: v_off_ini = 2395.526 uV, v_off_fin = 2391.634 uV 13:26:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.123 uVs 13:26:45 Integrated Voltage Measurement... 13:26:54 Voltage Offset Correction: v_off_ini = 2374.691 uV, v_off_fin = 2376.462 uV 13:26:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.034 uVs 13:26:54 Integrated Voltage Measurement... 13:27:03 Voltage Offset Correction: v_off_ini = 2382.553 uV, v_off_fin = 2414.293 uV 13:27:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.171 uVs 13:27:03 Integrated Voltage Measurement... 13:27:12 Voltage Offset Correction: v_off_ini = 2400.599 uV, v_off_fin = 2398.002 uV 13:27:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.712 uVs 13:27:12 Integrated Voltage Measurement... 13:27:21 Voltage Offset Correction: v_off_ini = 2403.918 uV, v_off_fin = 2407.784 uV 13:27:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.691 uVs 13:27:25 I1Y Average and RMS of Measurements VT = -200.081 +- 6.034 uVs I1Y = -40.016 +- 1.207 uTm 13:27:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:27:33 Integrated Voltage Measurement... 13:27:42 Voltage Offset Correction: v_off_ini = 2421.325 uV, v_off_fin = 2391.553 uV 13:27:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.804 uVs 13:27:42 Integrated Voltage Measurement... 13:27:51 Voltage Offset Correction: v_off_ini = 2382.545 uV, v_off_fin = 2406.847 uV 13:27:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.397 uVs 13:27:51 Integrated Voltage Measurement... 13:28:00 Voltage Offset Correction: v_off_ini = 2388.113 uV, v_off_fin = 2368.590 uV 13:28:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -67.567 uVs 13:28:00 Integrated Voltage Measurement... 13:28:09 Voltage Offset Correction: v_off_ini = 2377.329 uV, v_off_fin = 2377.149 uV 13:28:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.453 uVs 13:28:09 Integrated Voltage Measurement... 13:28:18 Voltage Offset Correction: v_off_ini = 2366.363 uV, v_off_fin = 2369.219 uV 13:28:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.462 uVs 13:28:18 Integrated Voltage Measurement... 13:28:27 Voltage Offset Correction: v_off_ini = 2365.488 uV, v_off_fin = 2364.643 uV 13:28:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.316 uVs 13:28:30 I2X Average and RMS of Measurements VT = -85.333 +- 14.048 uVs I2X = 7.851 +- 1.292 uTm^2 13:28:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:28:37 Integrated Voltage Measurement... 13:28:46 Voltage Offset Correction: v_off_ini = 2364.168 uV, v_off_fin = 2359.970 uV 13:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.668 uVs 13:28:46 Integrated Voltage Measurement... 13:28:55 Voltage Offset Correction: v_off_ini = 2383.196 uV, v_off_fin = 2375.152 uV 13:28:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.324 uVs 13:28:55 Integrated Voltage Measurement... 13:29:04 Voltage Offset Correction: v_off_ini = 2355.052 uV, v_off_fin = 2350.180 uV 13:29:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.600 uVs 13:29:04 Integrated Voltage Measurement... 13:29:13 Voltage Offset Correction: v_off_ini = 2374.527 uV, v_off_fin = 2372.409 uV 13:29:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.874 uVs 13:29:13 Integrated Voltage Measurement... 13:29:22 Voltage Offset Correction: v_off_ini = 2373.681 uV, v_off_fin = 2368.748 uV 13:29:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.969 uVs 13:29:22 Integrated Voltage Measurement... 13:29:31 Voltage Offset Correction: v_off_ini = 2378.913 uV, v_off_fin = 2377.048 uV 13:29:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.749 uVs 13:29:34 I2Y Average and RMS of Measurements VT = -318.531 +- 16.306 uVs I2Y = -29.305 +- 1.500 uTm^2 13:29:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:29:43 Integrated Voltage Measurement... 13:29:52 Voltage Offset Correction: v_off_ini = 2349.955 uV, v_off_fin = 2347.012 uV 13:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.765 uVs 13:29:52 Integrated Voltage Measurement... 13:30:01 Voltage Offset Correction: v_off_ini = 2352.799 uV, v_off_fin = 2378.791 uV 13:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.715 uVs 13:30:01 Integrated Voltage Measurement... 13:30:10 Voltage Offset Correction: v_off_ini = 2367.867 uV, v_off_fin = 2374.934 uV 13:30:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.083 uVs 13:30:10 Integrated Voltage Measurement... 13:30:19 Voltage Offset Correction: v_off_ini = 2353.391 uV, v_off_fin = 2336.842 uV 13:30:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.118 uVs 13:30:19 Integrated Voltage Measurement... 13:30:28 Voltage Offset Correction: v_off_ini = 2352.375 uV, v_off_fin = 2344.096 uV 13:30:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.716 uVs 13:30:28 Integrated Voltage Measurement... 13:30:37 Voltage Offset Correction: v_off_ini = 2347.146 uV, v_off_fin = 2347.052 uV 13:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.025 uVs 13:30:41 I1X Average and RMS of Measurements VT = -73.570 +- 2.600 uVs I1X = 14.714 +- 0.520 uTm 13:30:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:30:48 Integrated Voltage Measurement... 13:30:57 Voltage Offset Correction: v_off_ini = 2339.969 uV, v_off_fin = 2330.714 uV 13:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.896 uVs 13:30:57 Integrated Voltage Measurement... 13:31:06 Voltage Offset Correction: v_off_ini = 2339.370 uV, v_off_fin = 2355.841 uV 13:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.435 uVs 13:31:06 Integrated Voltage Measurement... 13:31:15 Voltage Offset Correction: v_off_ini = 2321.084 uV, v_off_fin = 2347.855 uV 13:31:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.013 uVs 13:31:15 Integrated Voltage Measurement... 13:31:24 Voltage Offset Correction: v_off_ini = 2347.516 uV, v_off_fin = 2352.377 uV 13:31:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.119 uVs 13:31:24 Integrated Voltage Measurement... 13:31:33 Voltage Offset Correction: v_off_ini = 2323.309 uV, v_off_fin = 2307.573 uV 13:31:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.770 uVs 13:31:33 Integrated Voltage Measurement... 13:31:42 Voltage Offset Correction: v_off_ini = 2326.416 uV, v_off_fin = 2317.399 uV 13:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.631 uVs 13:31:46 I1Y Average and RMS of Measurements VT = -197.644 +- 6.412 uVs I1Y = -39.529 +- 1.282 uTm 13:31:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:31:53 Integrated Voltage Measurement... 13:32:02 Voltage Offset Correction: v_off_ini = 2370.570 uV, v_off_fin = 2360.294 uV 13:32:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.367 uVs 13:32:02 Integrated Voltage Measurement... 13:32:11 Voltage Offset Correction: v_off_ini = 2368.367 uV, v_off_fin = 2354.411 uV 13:32:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.000 uVs 13:32:11 Integrated Voltage Measurement... 13:32:20 Voltage Offset Correction: v_off_ini = 2364.069 uV, v_off_fin = 2334.711 uV 13:32:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.866 uVs 13:32:21 Integrated Voltage Measurement... 13:32:29 Voltage Offset Correction: v_off_ini = 2360.702 uV, v_off_fin = 2389.137 uV 13:32:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.613 uVs 13:32:30 Integrated Voltage Measurement... 13:32:39 Voltage Offset Correction: v_off_ini = 2374.136 uV, v_off_fin = 2369.894 uV 13:32:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.690 uVs 13:32:39 Integrated Voltage Measurement... 13:32:48 Voltage Offset Correction: v_off_ini = 2376.179 uV, v_off_fin = 2365.784 uV 13:32:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.190 uVs 13:32:50 I2X Average and RMS of Measurements VT = -84.621 +- 6.919 uVs I2X = 7.785 +- 0.636 uTm^2 13:32:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:58 Integrated Voltage Measurement... 13:33:07 Voltage Offset Correction: v_off_ini = 2361.917 uV, v_off_fin = 2357.575 uV 13:33:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -342.919 uVs 13:33:07 Integrated Voltage Measurement... 13:33:16 Voltage Offset Correction: v_off_ini = 2344.374 uV, v_off_fin = 2370.146 uV 13:33:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.477 uVs 13:33:16 Integrated Voltage Measurement... 13:33:25 Voltage Offset Correction: v_off_ini = 2363.570 uV, v_off_fin = 2358.980 uV 13:33:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.676 uVs 13:33:25 Integrated Voltage Measurement... 13:33:34 Voltage Offset Correction: v_off_ini = 2371.744 uV, v_off_fin = 2371.866 uV 13:33:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.149 uVs 13:33:34 Integrated Voltage Measurement... 13:33:43 Voltage Offset Correction: v_off_ini = 2377.043 uV, v_off_fin = 2388.307 uV 13:33:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.898 uVs 13:33:43 Integrated Voltage Measurement... 13:33:52 Voltage Offset Correction: v_off_ini = 2395.856 uV, v_off_fin = 2393.822 uV 13:33:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.531 uVs 13:33:54 I2Y Average and RMS of Measurements VT = -335.442 +- 12.285 uVs I2Y = -30.861 +- 1.131 uTm^2 13:33:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:34:03 Integrated Voltage Measurement... 13:34:12 Voltage Offset Correction: v_off_ini = 2405.821 uV, v_off_fin = 2376.581 uV 13:34:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -49.980 uVs 13:34:12 Integrated Voltage Measurement... 13:34:21 Voltage Offset Correction: v_off_ini = 2397.183 uV, v_off_fin = 2367.684 uV 13:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.059 uVs 13:34:21 Integrated Voltage Measurement... 13:34:30 Voltage Offset Correction: v_off_ini = 2401.883 uV, v_off_fin = 2387.511 uV 13:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.121 uVs 13:34:30 Integrated Voltage Measurement... 13:34:39 Voltage Offset Correction: v_off_ini = 2390.133 uV, v_off_fin = 2385.128 uV 13:34:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.972 uVs 13:34:39 Integrated Voltage Measurement... 13:34:48 Voltage Offset Correction: v_off_ini = 2361.809 uV, v_off_fin = 2377.728 uV 13:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.571 uVs 13:34:48 Integrated Voltage Measurement... 13:34:57 Voltage Offset Correction: v_off_ini = 2380.163 uV, v_off_fin = 2362.727 uV 13:34:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.670 uVs 13:35:01 I1X Average and RMS of Measurements VT = -56.396 +- 3.270 uVs I1X = 11.280 +- 0.655 uTm 13:35:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:35:08 Integrated Voltage Measurement... 13:35:17 Voltage Offset Correction: v_off_ini = 2371.097 uV, v_off_fin = 2371.648 uV 13:35:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -186.494 uVs 13:35:17 Integrated Voltage Measurement... 13:35:26 Voltage Offset Correction: v_off_ini = 2377.184 uV, v_off_fin = 2356.180 uV 13:35:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.594 uVs 13:35:26 Integrated Voltage Measurement... 13:35:35 Voltage Offset Correction: v_off_ini = 2362.630 uV, v_off_fin = 2353.881 uV 13:35:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.897 uVs 13:35:35 Integrated Voltage Measurement... 13:35:44 Voltage Offset Correction: v_off_ini = 2363.766 uV, v_off_fin = 2364.069 uV 13:35:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.246 uVs 13:35:44 Integrated Voltage Measurement... 13:35:53 Voltage Offset Correction: v_off_ini = 2369.528 uV, v_off_fin = 2364.487 uV 13:35:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.413 uVs 13:35:53 Integrated Voltage Measurement... 13:36:02 Voltage Offset Correction: v_off_ini = 2382.320 uV, v_off_fin = 2379.871 uV 13:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.453 uVs 13:36:06 I1Y Average and RMS of Measurements VT = -201.516 +- 9.471 uVs I1Y = -40.304 +- 1.894 uTm 13:36:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:36:14 Integrated Voltage Measurement... 13:36:23 Voltage Offset Correction: v_off_ini = 2359.004 uV, v_off_fin = 2356.771 uV 13:36:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.505 uVs 13:36:23 Integrated Voltage Measurement... 13:36:32 Voltage Offset Correction: v_off_ini = 2359.492 uV, v_off_fin = 2380.407 uV 13:36:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.770 uVs 13:36:32 Integrated Voltage Measurement... 13:36:41 Voltage Offset Correction: v_off_ini = 2390.742 uV, v_off_fin = 2372.955 uV 13:36:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.927 uVs 13:36:41 Integrated Voltage Measurement... 13:36:50 Voltage Offset Correction: v_off_ini = 2364.974 uV, v_off_fin = 2367.295 uV 13:36:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.697 uVs 13:36:50 Integrated Voltage Measurement... 13:36:59 Voltage Offset Correction: v_off_ini = 2387.496 uV, v_off_fin = 2344.453 uV 13:36:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.843 uVs 13:36:59 Integrated Voltage Measurement... 13:37:08 Voltage Offset Correction: v_off_ini = 2378.652 uV, v_off_fin = 2405.826 uV 13:37:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.408 uVs 13:37:10 I2X Average and RMS of Measurements VT = -66.858 +- 29.530 uVs I2X = 6.151 +- 2.717 uTm^2 13:37:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:37:18 Integrated Voltage Measurement... 13:37:27 Voltage Offset Correction: v_off_ini = 2367.419 uV, v_off_fin = 2391.928 uV 13:37:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0001 mm dXY = 1.0000 mm VT = -264.142 uVs 13:37:27 Integrated Voltage Measurement... 13:37:36 Voltage Offset Correction: v_off_ini = 2402.160 uV, v_off_fin = 2411.037 uV 13:37:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.255 uVs 13:37:36 Integrated Voltage Measurement... 13:37:45 Voltage Offset Correction: v_off_ini = 2416.901 uV, v_off_fin = 2388.250 uV 13:37:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.246 uVs 13:37:45 Integrated Voltage Measurement... 13:37:54 Voltage Offset Correction: v_off_ini = 2389.698 uV, v_off_fin = 2388.310 uV 13:37:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.697 uVs 13:37:54 Integrated Voltage Measurement... 13:38:03 Voltage Offset Correction: v_off_ini = 2380.996 uV, v_off_fin = 2389.347 uV 13:38:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.290 uVs 13:38:03 Integrated Voltage Measurement... 13:38:12 Voltage Offset Correction: v_off_ini = 2392.482 uV, v_off_fin = 2379.800 uV 13:38:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.744 uVs 13:38:15 I2Y Average and RMS of Measurements VT = -306.396 +- 17.002 uVs I2Y = -28.188 +- 1.564 uTm^2 13:38:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:38:24 Integrated Voltage Measurement... 13:38:33 Voltage Offset Correction: v_off_ini = 2363.588 uV, v_off_fin = 2357.667 uV 13:38:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.612 uVs 13:38:33 Integrated Voltage Measurement... 13:38:42 Voltage Offset Correction: v_off_ini = 2348.361 uV, v_off_fin = 2365.257 uV 13:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.055 uVs 13:38:42 Integrated Voltage Measurement... 13:38:51 Voltage Offset Correction: v_off_ini = 2353.710 uV, v_off_fin = 2360.806 uV 13:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.824 uVs 13:38:51 Integrated Voltage Measurement... 13:39:00 Voltage Offset Correction: v_off_ini = 2394.940 uV, v_off_fin = 2392.086 uV 13:39:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.951 uVs 13:39:00 Integrated Voltage Measurement... 13:39:09 Voltage Offset Correction: v_off_ini = 2359.892 uV, v_off_fin = 2377.294 uV 13:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -7.421 uVs 13:39:09 Integrated Voltage Measurement... 13:39:18 Voltage Offset Correction: v_off_ini = 2406.784 uV, v_off_fin = 2399.331 uV 13:39:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.413 uVs 13:39:22 I1X Average and RMS of Measurements VT = -51.213 +- 17.920 uVs I1X = 10.243 +- 3.584 uTm 13:39:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:39:29 Integrated Voltage Measurement... 13:39:38 Voltage Offset Correction: v_off_ini = 2355.097 uV, v_off_fin = 2386.237 uV 13:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.162 uVs 13:39:38 Integrated Voltage Measurement... 13:39:47 Voltage Offset Correction: v_off_ini = 2382.786 uV, v_off_fin = 2396.794 uV 13:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.848 uVs 13:39:47 Integrated Voltage Measurement... 13:39:56 Voltage Offset Correction: v_off_ini = 2376.807 uV, v_off_fin = 2374.035 uV 13:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.502 uVs 13:39:56 Integrated Voltage Measurement... 13:40:05 Voltage Offset Correction: v_off_ini = 2367.868 uV, v_off_fin = 2393.783 uV 13:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.845 uVs 13:40:05 Integrated Voltage Measurement... 13:40:14 Voltage Offset Correction: v_off_ini = 2405.949 uV, v_off_fin = 2393.340 uV 13:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.135 uVs 13:40:14 Integrated Voltage Measurement... 13:40:23 Voltage Offset Correction: v_off_ini = 2367.395 uV, v_off_fin = 2395.504 uV 13:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.385 uVs 13:40:27 I1Y Average and RMS of Measurements VT = -197.813 +- 0.275 uVs I1Y = -39.563 +- 0.055 uTm 13:40:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:40:34 Integrated Voltage Measurement... 13:40:43 Voltage Offset Correction: v_off_ini = 2369.398 uV, v_off_fin = 2369.294 uV 13:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.759 uVs 13:40:44 Integrated Voltage Measurement... 13:40:52 Voltage Offset Correction: v_off_ini = 2377.074 uV, v_off_fin = 2372.473 uV 13:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.130 uVs 13:40:53 Integrated Voltage Measurement... 13:41:02 Voltage Offset Correction: v_off_ini = 2362.229 uV, v_off_fin = 2349.146 uV 13:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.222 uVs 13:41:02 Integrated Voltage Measurement... 13:41:11 Voltage Offset Correction: v_off_ini = 2383.811 uV, v_off_fin = 2391.108 uV 13:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.780 uVs 13:41:11 Integrated Voltage Measurement... 13:41:20 Voltage Offset Correction: v_off_ini = 2364.560 uV, v_off_fin = 2359.343 uV 13:41:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -25.626 uVs 13:41:20 Integrated Voltage Measurement... 13:41:29 Voltage Offset Correction: v_off_ini = 2359.721 uV, v_off_fin = 2407.988 uV 13:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.589 uVs 13:41:31 I2X Average and RMS of Measurements VT = -45.684 +- 5.237 uVs I2X = 4.203 +- 0.482 uTm^2 13:41:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:41:39 Integrated Voltage Measurement... 13:41:48 Voltage Offset Correction: v_off_ini = 2402.384 uV, v_off_fin = 2401.612 uV 13:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.202 uVs 13:41:48 Integrated Voltage Measurement... 13:41:57 Voltage Offset Correction: v_off_ini = 2391.230 uV, v_off_fin = 2382.023 uV 13:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.783 uVs 13:41:57 Integrated Voltage Measurement... 13:42:06 Voltage Offset Correction: v_off_ini = 2395.949 uV, v_off_fin = 2414.141 uV 13:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.968 uVs 13:42:06 Integrated Voltage Measurement... 13:42:15 Voltage Offset Correction: v_off_ini = 2386.903 uV, v_off_fin = 2393.031 uV 13:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.444 uVs 13:42:15 Integrated Voltage Measurement... 13:42:24 Voltage Offset Correction: v_off_ini = 2399.973 uV, v_off_fin = 2382.349 uV 13:42:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.703 uVs 13:42:24 Integrated Voltage Measurement... 13:42:33 Voltage Offset Correction: v_off_ini = 2372.276 uV, v_off_fin = 2394.124 uV 13:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.042 uVs 13:42:35 I2Y Average and RMS of Measurements VT = -317.357 +- 13.224 uVs I2Y = -29.197 +- 1.217 uTm^2 13:42:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:42:47 Integrated Voltage Measurement... 13:42:56 Voltage Offset Correction: v_off_ini = 2425.950 uV, v_off_fin = 2398.233 uV 13:42:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -83.137 uVs 13:42:56 Integrated Voltage Measurement... 13:43:05 Voltage Offset Correction: v_off_ini = 2397.188 uV, v_off_fin = 2388.674 uV 13:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.199 uVs 13:43:05 Integrated Voltage Measurement... 13:43:14 Voltage Offset Correction: v_off_ini = 2413.009 uV, v_off_fin = 2414.831 uV 13:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.738 uVs 13:43:14 Integrated Voltage Measurement... 13:43:23 Voltage Offset Correction: v_off_ini = 2416.649 uV, v_off_fin = 2435.206 uV 13:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.408 uVs 13:43:23 Integrated Voltage Measurement... 13:43:32 Voltage Offset Correction: v_off_ini = 2435.775 uV, v_off_fin = 2422.502 uV 13:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.892 uVs 13:43:32 Integrated Voltage Measurement... 13:43:41 Voltage Offset Correction: v_off_ini = 2409.404 uV, v_off_fin = 2428.946 uV 13:43:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.685 uVs 13:43:45 I1X Average and RMS of Measurements VT = -73.343 +- 9.966 uVs I1X = 14.669 +- 1.993 uTm 13:43:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:43:52 Integrated Voltage Measurement... 13:44:01 Voltage Offset Correction: v_off_ini = 2424.079 uV, v_off_fin = 2404.625 uV 13:44:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.012 uVs 13:44:01 Integrated Voltage Measurement... 13:44:10 Voltage Offset Correction: v_off_ini = 2408.540 uV, v_off_fin = 2426.078 uV 13:44:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.907 uVs 13:44:10 Integrated Voltage Measurement... 13:44:19 Voltage Offset Correction: v_off_ini = 2425.616 uV, v_off_fin = 2420.282 uV 13:44:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.064 uVs 13:44:19 Integrated Voltage Measurement... 13:44:28 Voltage Offset Correction: v_off_ini = 2408.429 uV, v_off_fin = 2409.869 uV 13:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.811 uVs 13:44:28 Integrated Voltage Measurement... 13:44:37 Voltage Offset Correction: v_off_ini = 2409.792 uV, v_off_fin = 2389.686 uV 13:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.631 uVs 13:44:37 Integrated Voltage Measurement... 13:44:46 Voltage Offset Correction: v_off_ini = 2410.463 uV, v_off_fin = 2438.085 uV 13:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.360 uVs 13:44:50 I1Y Average and RMS of Measurements VT = -211.631 +- 14.085 uVs I1Y = -42.326 +- 2.817 uTm 13:44:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:44:55 Integrated Voltage Measurement... 13:45:04 Voltage Offset Correction: v_off_ini = 2420.852 uV, v_off_fin = 2402.710 uV 13:45:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -61.622 uVs 13:45:04 Integrated Voltage Measurement... 13:45:13 Voltage Offset Correction: v_off_ini = 2393.244 uV, v_off_fin = 2392.829 uV 13:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.489 uVs 13:45:13 Integrated Voltage Measurement... 13:45:22 Voltage Offset Correction: v_off_ini = 2427.779 uV, v_off_fin = 2421.585 uV 13:45:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.572 uVs 13:45:22 Integrated Voltage Measurement... 13:45:31 Voltage Offset Correction: v_off_ini = 2424.251 uV, v_off_fin = 2435.007 uV 13:45:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.525 uVs 13:45:31 Integrated Voltage Measurement... 13:45:40 Voltage Offset Correction: v_off_ini = 2428.057 uV, v_off_fin = 2413.300 uV 13:45:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.512 uVs 13:45:40 Integrated Voltage Measurement... 13:45:49 Voltage Offset Correction: v_off_ini = 2414.448 uV, v_off_fin = 2478.169 uV 13:45:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 78.657 uVs 13:45:52 I2X Average and RMS of Measurements VT = -76.230 +- 20.413 uVs I2X = 7.013 +- 1.878 uTm^2 13:45:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:45:57 Integrated Voltage Measurement... 13:46:06 Voltage Offset Correction: v_off_ini = 2448.503 uV, v_off_fin = 2439.527 uV 13:46:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -365.056 uVs 13:46:06 Integrated Voltage Measurement... 13:46:15 Voltage Offset Correction: v_off_ini = 2420.615 uV, v_off_fin = 2423.467 uV 13:46:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 347.618 uVs 13:46:15 Integrated Voltage Measurement... 13:46:24 Voltage Offset Correction: v_off_ini = 2464.614 uV, v_off_fin = 2456.890 uV 13:46:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -352.500 uVs 13:46:24 Integrated Voltage Measurement... 13:46:33 Voltage Offset Correction: v_off_ini = 2432.311 uV, v_off_fin = 2424.076 uV 13:46:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.195 uVs 13:46:33 Integrated Voltage Measurement... 13:46:42 Voltage Offset Correction: v_off_ini = 2443.943 uV, v_off_fin = 2434.208 uV 13:46:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.124 uVs 13:46:42 Integrated Voltage Measurement... 13:46:51 Voltage Offset Correction: v_off_ini = 2438.681 uV, v_off_fin = 2421.418 uV 13:46:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.969 uVs 13:46:54 I2Y Average and RMS of Measurements VT = -335.744 +- 16.655 uVs I2Y = -30.888 +- 1.532 uTm^2 13:46:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:47:02 Integrated Voltage Measurement... 13:47:11 Voltage Offset Correction: v_off_ini = 2430.046 uV, v_off_fin = 2434.390 uV 13:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.712 uVs 13:47:11 Integrated Voltage Measurement... 13:47:20 Voltage Offset Correction: v_off_ini = 2443.382 uV, v_off_fin = 2436.377 uV 13:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 12.562 uVs 13:47:20 Integrated Voltage Measurement... 13:47:29 Voltage Offset Correction: v_off_ini = 2458.691 uV, v_off_fin = 2430.651 uV 13:47:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.666 uVs 13:47:29 Integrated Voltage Measurement... 13:47:38 Voltage Offset Correction: v_off_ini = 2418.136 uV, v_off_fin = 2413.204 uV 13:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 70.727 uVs 13:47:38 Integrated Voltage Measurement... 13:47:47 Voltage Offset Correction: v_off_ini = 2426.215 uV, v_off_fin = 2419.231 uV 13:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.899 uVs 13:47:47 Integrated Voltage Measurement... 13:47:56 Voltage Offset Correction: v_off_ini = 2428.969 uV, v_off_fin = 2429.648 uV 13:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.708 uVs 13:48:00 I1X Average and RMS of Measurements VT = -70.879 +- 10.491 uVs I1X = 14.176 +- 2.099 uTm 13:48:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:48:07 Integrated Voltage Measurement... 13:48:16 Voltage Offset Correction: v_off_ini = 2445.057 uV, v_off_fin = 2423.152 uV 13:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.276 uVs 13:48:16 Integrated Voltage Measurement... 13:48:25 Voltage Offset Correction: v_off_ini = 2428.288 uV, v_off_fin = 2450.941 uV 13:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.352 uVs 13:48:25 Integrated Voltage Measurement... 13:48:34 Voltage Offset Correction: v_off_ini = 2449.610 uV, v_off_fin = 2431.706 uV 13:48:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.459 uVs 13:48:34 Integrated Voltage Measurement... 13:48:43 Voltage Offset Correction: v_off_ini = 2440.365 uV, v_off_fin = 2454.151 uV 13:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.356 uVs 13:48:43 Integrated Voltage Measurement... 13:48:52 Voltage Offset Correction: v_off_ini = 2425.529 uV, v_off_fin = 2436.013 uV 13:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.908 uVs 13:48:52 Integrated Voltage Measurement... 13:49:01 Voltage Offset Correction: v_off_ini = 2443.065 uV, v_off_fin = 2457.963 uV 13:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.409 uVs 13:49:05 I1Y Average and RMS of Measurements VT = -193.293 +- 11.982 uVs I1Y = -38.659 +- 2.396 uTm 13:49:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:49:10 Integrated Voltage Measurement... 13:49:19 Voltage Offset Correction: v_off_ini = 2449.014 uV, v_off_fin = 2420.682 uV 13:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.216 uVs 13:49:19 Integrated Voltage Measurement... 13:49:28 Voltage Offset Correction: v_off_ini = 2436.098 uV, v_off_fin = 2430.160 uV 13:49:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.314 uVs 13:49:28 Integrated Voltage Measurement... 13:49:37 Voltage Offset Correction: v_off_ini = 2428.919 uV, v_off_fin = 2427.945 uV 13:49:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.839 uVs 13:49:37 Integrated Voltage Measurement... 13:49:46 Voltage Offset Correction: v_off_ini = 2432.698 uV, v_off_fin = 2434.078 uV 13:49:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.826 uVs 13:49:46 Integrated Voltage Measurement... 13:49:55 Voltage Offset Correction: v_off_ini = 2426.402 uV, v_off_fin = 2429.676 uV 13:49:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.278 uVs 13:49:55 Integrated Voltage Measurement... 13:50:04 Voltage Offset Correction: v_off_ini = 2431.943 uV, v_off_fin = 2426.708 uV 13:50:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.431 uVs 13:50:07 I2X Average and RMS of Measurements VT = -73.817 +- 4.549 uVs I2X = 6.791 +- 0.419 uTm^2 13:50:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:50:12 Integrated Voltage Measurement... 13:50:21 Voltage Offset Correction: v_off_ini = 2420.081 uV, v_off_fin = 2423.288 uV 13:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.094 uVs 13:50:21 Integrated Voltage Measurement... 13:50:30 Voltage Offset Correction: v_off_ini = 2391.441 uV, v_off_fin = 2439.505 uV 13:50:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.867 uVs 13:50:30 Integrated Voltage Measurement... 13:50:39 Voltage Offset Correction: v_off_ini = 2429.633 uV, v_off_fin = 2414.945 uV 13:50:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.788 uVs 13:50:39 Integrated Voltage Measurement... 13:50:48 Voltage Offset Correction: v_off_ini = 2402.095 uV, v_off_fin = 2407.195 uV 13:50:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.966 uVs 13:50:48 Integrated Voltage Measurement... 13:50:57 Voltage Offset Correction: v_off_ini = 2405.351 uV, v_off_fin = 2419.585 uV 13:50:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.224 uVs 13:50:57 Integrated Voltage Measurement... 13:51:06 Voltage Offset Correction: v_off_ini = 2421.363 uV, v_off_fin = 2407.933 uV 13:51:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.703 uVs 13:51:08 I2Y Average and RMS of Measurements VT = -320.607 +- 12.082 uVs I2Y = -29.496 +- 1.112 uTm^2 13:51:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:17 Integrated Voltage Measurement... 13:51:25 Voltage Offset Correction: v_off_ini = 2400.061 uV, v_off_fin = 2394.593 uV 13:51:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -73.691 uVs 13:51:26 Integrated Voltage Measurement... 13:51:34 Voltage Offset Correction: v_off_ini = 2400.086 uV, v_off_fin = 2435.705 uV 13:51:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.107 uVs 13:51:35 Integrated Voltage Measurement... 13:51:43 Voltage Offset Correction: v_off_ini = 2415.143 uV, v_off_fin = 2381.929 uV 13:51:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.402 uVs 13:51:44 Integrated Voltage Measurement... 13:51:52 Voltage Offset Correction: v_off_ini = 2365.334 uV, v_off_fin = 2390.893 uV 13:51:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.796 uVs 13:51:53 Integrated Voltage Measurement... 13:52:02 Voltage Offset Correction: v_off_ini = 2363.550 uV, v_off_fin = 2346.024 uV 13:52:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.514 uVs 13:52:02 Integrated Voltage Measurement... 13:52:11 Voltage Offset Correction: v_off_ini = 2368.644 uV, v_off_fin = 2382.883 uV 13:52:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.160 uVs 13:52:15 I1X Average and RMS of Measurements VT = -76.612 +- 10.725 uVs I1X = 15.323 +- 2.144 uTm 13:52:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:22 Integrated Voltage Measurement... 13:52:30 Voltage Offset Correction: v_off_ini = 2386.128 uV, v_off_fin = 2367.273 uV 13:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.344 uVs 13:52:31 Integrated Voltage Measurement... 13:52:39 Voltage Offset Correction: v_off_ini = 2400.529 uV, v_off_fin = 2402.942 uV 13:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.317 uVs 13:52:40 Integrated Voltage Measurement... 13:52:48 Voltage Offset Correction: v_off_ini = 2384.474 uV, v_off_fin = 2359.165 uV 13:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.025 uVs 13:52:49 Integrated Voltage Measurement... 13:52:57 Voltage Offset Correction: v_off_ini = 2387.799 uV, v_off_fin = 2411.607 uV 13:52:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.298 uVs 13:52:58 Integrated Voltage Measurement... 13:53:06 Voltage Offset Correction: v_off_ini = 2389.731 uV, v_off_fin = 2398.306 uV 13:53:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.989 uVs 13:53:07 Integrated Voltage Measurement... 13:53:15 Voltage Offset Correction: v_off_ini = 2387.098 uV, v_off_fin = 2391.848 uV 13:53:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.660 uVs 13:53:20 I1Y Average and RMS of Measurements VT = -190.939 +- 3.693 uVs I1Y = -38.188 +- 0.739 uTm 13:53:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:25 Integrated Voltage Measurement... 13:53:34 Voltage Offset Correction: v_off_ini = 2397.689 uV, v_off_fin = 2383.482 uV 13:53:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.485 uVs 13:53:34 Integrated Voltage Measurement... 13:53:43 Voltage Offset Correction: v_off_ini = 2383.815 uV, v_off_fin = 2378.836 uV 13:53:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.528 uVs 13:53:43 Integrated Voltage Measurement... 13:53:52 Voltage Offset Correction: v_off_ini = 2399.732 uV, v_off_fin = 2380.422 uV 13:53:52 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.854 uVs 13:53:52 Integrated Voltage Measurement... 13:54:01 Voltage Offset Correction: v_off_ini = 2384.835 uV, v_off_fin = 2418.573 uV 13:54:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 85.012 uVs 13:54:01 Integrated Voltage Measurement... 13:54:10 Voltage Offset Correction: v_off_ini = 2415.921 uV, v_off_fin = 2414.990 uV 13:54:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -68.048 uVs 13:54:10 Integrated Voltage Measurement... 13:54:19 Voltage Offset Correction: v_off_ini = 2396.870 uV, v_off_fin = 2373.028 uV 13:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.176 uVs 13:54:21 I2X Average and RMS of Measurements VT = -78.517 +- 4.951 uVs I2X = 7.224 +- 0.456 uTm^2 13:54:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:26 Integrated Voltage Measurement... 13:54:35 Voltage Offset Correction: v_off_ini = 2388.531 uV, v_off_fin = 2365.495 uV 13:54:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.663 uVs 13:54:35 Integrated Voltage Measurement... 13:54:44 Voltage Offset Correction: v_off_ini = 2387.201 uV, v_off_fin = 2396.559 uV 13:54:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.673 uVs 13:54:45 Integrated Voltage Measurement... 13:54:53 Voltage Offset Correction: v_off_ini = 2389.635 uV, v_off_fin = 2393.077 uV 13:54:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.657 uVs 13:54:54 Integrated Voltage Measurement... 13:55:03 Voltage Offset Correction: v_off_ini = 2383.962 uV, v_off_fin = 2373.445 uV 13:55:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.910 uVs 13:55:03 Integrated Voltage Measurement... 13:55:12 Voltage Offset Correction: v_off_ini = 2368.499 uV, v_off_fin = 2379.761 uV 13:55:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.692 uVs 13:55:12 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = 2401.197 uV, v_off_fin = 2396.140 uV 13:55:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.941 uVs 13:55:23 I2Y Average and RMS of Measurements VT = -318.256 +- 5.294 uVs I2Y = -29.280 +- 0.487 uTm^2 13:55:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:55:31 Integrated Voltage Measurement... 13:55:40 Voltage Offset Correction: v_off_ini = 2377.011 uV, v_off_fin = 2359.183 uV 13:55:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.520 uVs 13:55:40 Integrated Voltage Measurement... 13:55:49 Voltage Offset Correction: v_off_ini = 2358.293 uV, v_off_fin = 2346.046 uV 13:55:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.111 uVs 13:55:49 Integrated Voltage Measurement... 13:55:58 Voltage Offset Correction: v_off_ini = 2353.504 uV, v_off_fin = 2358.841 uV 13:55:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.273 uVs 13:55:58 Integrated Voltage Measurement... 13:56:07 Voltage Offset Correction: v_off_ini = 2346.412 uV, v_off_fin = 2368.019 uV 13:56:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.065 uVs 13:56:07 Integrated Voltage Measurement... 13:56:16 Voltage Offset Correction: v_off_ini = 2353.602 uV, v_off_fin = 2367.172 uV 13:56:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.655 uVs 13:56:16 Integrated Voltage Measurement... 13:56:25 Voltage Offset Correction: v_off_ini = 2385.361 uV, v_off_fin = 2380.240 uV 13:56:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 107.867 uVs 13:56:30 I1X Average and RMS of Measurements VT = -75.915 +- 1.980 uVs I1X = 15.184 +- 0.396 uTm 13:56:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:56:36 Integrated Voltage Measurement... 13:56:45 Voltage Offset Correction: v_off_ini = 2400.360 uV, v_off_fin = 2382.300 uV 13:56:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.628 uVs 13:56:45 Integrated Voltage Measurement... 13:56:54 Voltage Offset Correction: v_off_ini = 2386.145 uV, v_off_fin = 2389.508 uV 13:56:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.783 uVs 13:56:54 Integrated Voltage Measurement... 13:57:03 Voltage Offset Correction: v_off_ini = 2401.871 uV, v_off_fin = 2392.236 uV 13:57:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.551 uVs 13:57:03 Integrated Voltage Measurement... 13:57:12 Voltage Offset Correction: v_off_ini = 2379.207 uV, v_off_fin = 2388.102 uV 13:57:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.378 uVs 13:57:12 Integrated Voltage Measurement... 13:57:21 Voltage Offset Correction: v_off_ini = 2393.097 uV, v_off_fin = 2368.289 uV 13:57:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.262 uVs 13:57:21 Integrated Voltage Measurement... 13:57:30 Voltage Offset Correction: v_off_ini = 2377.463 uV, v_off_fin = 2390.554 uV 13:57:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.867 uVs 13:57:34 I1Y Average and RMS of Measurements VT = -200.245 +- 6.646 uVs I1Y = -40.045 +- 1.329 uTm 13:57:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:57:40 Integrated Voltage Measurement... 13:57:49 Voltage Offset Correction: v_off_ini = 2404.641 uV, v_off_fin = 2385.288 uV 13:57:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.910 uVs 13:57:49 Integrated Voltage Measurement... 13:57:58 Voltage Offset Correction: v_off_ini = 2393.172 uV, v_off_fin = 2409.895 uV 13:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.441 uVs 13:57:58 Integrated Voltage Measurement... 13:58:07 Voltage Offset Correction: v_off_ini = 2389.598 uV, v_off_fin = 2379.951 uV 13:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.294 uVs 13:58:07 Integrated Voltage Measurement... 13:58:16 Voltage Offset Correction: v_off_ini = 2417.035 uV, v_off_fin = 2415.366 uV 13:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.565 uVs 13:58:16 Integrated Voltage Measurement... 13:58:25 Voltage Offset Correction: v_off_ini = 2400.759 uV, v_off_fin = 2382.524 uV 13:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.613 uVs 13:58:25 Integrated Voltage Measurement... 13:58:34 Voltage Offset Correction: v_off_ini = 2383.019 uV, v_off_fin = 2390.026 uV 13:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.578 uVs 13:58:36 I2X Average and RMS of Measurements VT = -82.400 +- 9.675 uVs I2X = 7.581 +- 0.890 uTm^2 13:58:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:58:41 Integrated Voltage Measurement... 13:58:50 Voltage Offset Correction: v_off_ini = 2371.781 uV, v_off_fin = 2368.595 uV 13:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.022 uVs 13:58:50 Integrated Voltage Measurement... 13:58:59 Voltage Offset Correction: v_off_ini = 2355.330 uV, v_off_fin = 2362.746 uV 13:58:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.256 uVs 13:58:59 Integrated Voltage Measurement... 13:59:08 Voltage Offset Correction: v_off_ini = 2351.225 uV, v_off_fin = 2354.689 uV 13:59:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.466 uVs 13:59:08 Integrated Voltage Measurement... 13:59:17 Voltage Offset Correction: v_off_ini = 2344.025 uV, v_off_fin = 2340.032 uV 13:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.976 uVs 13:59:17 Integrated Voltage Measurement... 13:59:26 Voltage Offset Correction: v_off_ini = 2343.252 uV, v_off_fin = 2342.309 uV 13:59:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.641 uVs 13:59:26 Integrated Voltage Measurement... 13:59:35 Voltage Offset Correction: v_off_ini = 2349.494 uV, v_off_fin = 2353.477 uV 13:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.030 uVs 13:59:38 I2Y Average and RMS of Measurements VT = -317.898 +- 4.874 uVs I2Y = -29.247 +- 0.448 uTm^2 13:59:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:59:46 Integrated Voltage Measurement... 13:59:55 Voltage Offset Correction: v_off_ini = 2392.535 uV, v_off_fin = 2360.096 uV 13:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.706 uVs 13:59:55 Integrated Voltage Measurement... 14:00:04 Voltage Offset Correction: v_off_ini = 2363.420 uV, v_off_fin = 2379.564 uV 14:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.695 uVs 14:00:04 Integrated Voltage Measurement... 14:00:13 Voltage Offset Correction: v_off_ini = 2384.702 uV, v_off_fin = 2381.485 uV 14:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.626 uVs 14:00:13 Integrated Voltage Measurement... 14:00:22 Voltage Offset Correction: v_off_ini = 2387.562 uV, v_off_fin = 2381.042 uV 14:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.925 uVs 14:00:22 Integrated Voltage Measurement... 14:00:31 Voltage Offset Correction: v_off_ini = 2371.251 uV, v_off_fin = 2366.159 uV 14:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.978 uVs 14:00:31 Integrated Voltage Measurement... 14:00:40 Voltage Offset Correction: v_off_ini = 2360.005 uV, v_off_fin = 2353.927 uV 14:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.310 uVs 14:00:44 I1X Average and RMS of Measurements VT = -61.707 +- 4.934 uVs I1X = 12.341 +- 0.987 uTm 14:00:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:00:51 Integrated Voltage Measurement... 14:01:00 Voltage Offset Correction: v_off_ini = 2384.763 uV, v_off_fin = 2371.431 uV 14:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.492 uVs 14:01:00 Integrated Voltage Measurement... 14:01:09 Voltage Offset Correction: v_off_ini = 2402.362 uV, v_off_fin = 2411.812 uV 14:01:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.474 uVs 14:01:09 Integrated Voltage Measurement... 14:01:18 Voltage Offset Correction: v_off_ini = 2404.802 uV, v_off_fin = 2372.982 uV 14:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.252 uVs 14:01:18 Integrated Voltage Measurement... 14:01:27 Voltage Offset Correction: v_off_ini = 2370.728 uV, v_off_fin = 2369.942 uV 14:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 213.451 uVs 14:01:27 Integrated Voltage Measurement... 14:01:36 Voltage Offset Correction: v_off_ini = 2362.716 uV, v_off_fin = 2364.982 uV 14:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.266 uVs 14:01:36 Integrated Voltage Measurement... 14:01:45 Voltage Offset Correction: v_off_ini = 2406.089 uV, v_off_fin = 2411.391 uV 14:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.732 uVs 14:01:49 I1Y Average and RMS of Measurements VT = -191.944 +- 4.900 uVs I1Y = -38.386 +- 0.981 uTm 14:01:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:01:54 Integrated Voltage Measurement... 14:02:03 Voltage Offset Correction: v_off_ini = 2377.172 uV, v_off_fin = 2381.531 uV 14:02:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -20.120 uVs 14:02:03 Integrated Voltage Measurement... 14:02:12 Voltage Offset Correction: v_off_ini = 2402.587 uV, v_off_fin = 2376.562 uV 14:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.086 uVs 14:02:12 Integrated Voltage Measurement... 14:02:21 Voltage Offset Correction: v_off_ini = 2391.058 uV, v_off_fin = 2372.593 uV 14:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.865 uVs 14:02:21 Integrated Voltage Measurement... 14:02:30 Voltage Offset Correction: v_off_ini = 2368.024 uV, v_off_fin = 2395.377 uV 14:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.160 uVs 14:02:30 Integrated Voltage Measurement... 14:02:39 Voltage Offset Correction: v_off_ini = 2399.492 uV, v_off_fin = 2385.908 uV 14:02:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.846 uVs 14:02:39 Integrated Voltage Measurement... 14:02:48 Voltage Offset Correction: v_off_ini = 2388.452 uV, v_off_fin = 2368.267 uV 14:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.655 uVs 14:02:51 I2X Average and RMS of Measurements VT = -63.789 +- 14.769 uVs I2X = 5.869 +- 1.359 uTm^2 14:02:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:02:56 Integrated Voltage Measurement... 14:03:05 Voltage Offset Correction: v_off_ini = 2355.171 uV, v_off_fin = 2370.123 uV 14:03:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.737 uVs 14:03:05 Integrated Voltage Measurement... 14:03:14 Voltage Offset Correction: v_off_ini = 2383.671 uV, v_off_fin = 2377.234 uV 14:03:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.697 uVs 14:03:14 Integrated Voltage Measurement... 14:03:23 Voltage Offset Correction: v_off_ini = 2363.310 uV, v_off_fin = 2366.520 uV 14:03:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.673 uVs 14:03:23 Integrated Voltage Measurement... 14:03:32 Voltage Offset Correction: v_off_ini = 2378.835 uV, v_off_fin = 2373.852 uV 14:03:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.298 uVs 14:03:32 Integrated Voltage Measurement... 14:03:41 Voltage Offset Correction: v_off_ini = 2405.324 uV, v_off_fin = 2386.859 uV 14:03:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.191 uVs 14:03:41 Integrated Voltage Measurement... 14:03:50 Voltage Offset Correction: v_off_ini = 2388.446 uV, v_off_fin = 2372.321 uV 14:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.941 uVs 14:03:53 I2Y Average and RMS of Measurements VT = -309.756 +- 3.610 uVs I2Y = -28.498 +- 0.332 uTm^2 14:04:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:04:14 Integrated Voltage Measurement... 14:04:23 Voltage Offset Correction: v_off_ini = 2385.740 uV, v_off_fin = 2386.468 uV 14:04:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.963 uVs 14:04:23 Integrated Voltage Measurement... 14:04:32 Voltage Offset Correction: v_off_ini = 2404.474 uV, v_off_fin = 2394.712 uV 14:04:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.820 uVs 14:04:32 Integrated Voltage Measurement... 14:04:41 Voltage Offset Correction: v_off_ini = 2385.712 uV, v_off_fin = 2370.480 uV 14:04:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.820 uVs 14:04:41 Integrated Voltage Measurement... 14:04:50 Voltage Offset Correction: v_off_ini = 2370.066 uV, v_off_fin = 2380.049 uV 14:04:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.294 uVs 14:04:50 Integrated Voltage Measurement... 14:04:59 Voltage Offset Correction: v_off_ini = 2392.377 uV, v_off_fin = 2393.918 uV 14:04:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.945 uVs 14:04:59 Integrated Voltage Measurement... 14:05:08 Voltage Offset Correction: v_off_ini = 2393.083 uV, v_off_fin = 2389.559 uV 14:05:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.471 uVs 14:05:12 I1X Average and RMS of Measurements VT = -86.885 +- 8.981 uVs I1X = 17.377 +- 1.796 uTm 14:05:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:05:19 Integrated Voltage Measurement... 14:05:28 Voltage Offset Correction: v_off_ini = 2376.155 uV, v_off_fin = 2361.333 uV 14:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.224 uVs 14:05:28 Integrated Voltage Measurement... 14:05:37 Voltage Offset Correction: v_off_ini = 2400.475 uV, v_off_fin = 2411.575 uV 14:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.335 uVs 14:05:37 Integrated Voltage Measurement... 14:05:46 Voltage Offset Correction: v_off_ini = 2404.682 uV, v_off_fin = 2385.640 uV 14:05:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.656 uVs 14:05:46 Integrated Voltage Measurement... 14:05:55 Voltage Offset Correction: v_off_ini = 2391.772 uV, v_off_fin = 2396.669 uV 14:05:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.233 uVs 14:05:55 Integrated Voltage Measurement... 14:06:04 Voltage Offset Correction: v_off_ini = 2371.327 uV, v_off_fin = 2370.475 uV 14:06:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.562 uVs 14:06:04 Integrated Voltage Measurement... 14:06:13 Voltage Offset Correction: v_off_ini = 2424.647 uV, v_off_fin = 2418.215 uV 14:06:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.996 uVs 14:06:17 I1Y Average and RMS of Measurements VT = -185.001 +- 15.742 uVs I1Y = -37.000 +- 3.148 uTm 14:06:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:06:25 Integrated Voltage Measurement... 14:06:34 Voltage Offset Correction: v_off_ini = 2392.566 uV, v_off_fin = 2388.614 uV 14:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.106 uVs 14:06:34 Integrated Voltage Measurement... 14:06:43 Voltage Offset Correction: v_off_ini = 2424.196 uV, v_off_fin = 2424.403 uV 14:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.431 uVs 14:06:43 Integrated Voltage Measurement... 14:06:52 Voltage Offset Correction: v_off_ini = 2410.456 uV, v_off_fin = 2410.745 uV 14:06:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.568 uVs 14:06:52 Integrated Voltage Measurement... 14:07:01 Voltage Offset Correction: v_off_ini = 2384.505 uV, v_off_fin = 2424.942 uV 14:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.282 uVs 14:07:01 Integrated Voltage Measurement... 14:07:10 Voltage Offset Correction: v_off_ini = 2431.137 uV, v_off_fin = 2406.062 uV 14:07:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.313 uVs 14:07:10 Integrated Voltage Measurement... 14:07:19 Voltage Offset Correction: v_off_ini = 2400.340 uV, v_off_fin = 2421.233 uV 14:07:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.108 uVs 14:07:21 I2X Average and RMS of Measurements VT = -94.801 +- 11.061 uVs I2X = 8.722 +- 1.018 uTm^2 14:07:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:07:29 Integrated Voltage Measurement... 14:07:38 Voltage Offset Correction: v_off_ini = 2414.202 uV, v_off_fin = 2424.927 uV 14:07:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.966 uVs 14:07:38 Integrated Voltage Measurement... 14:07:47 Voltage Offset Correction: v_off_ini = 2398.172 uV, v_off_fin = 2415.531 uV 14:07:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.197 uVs 14:07:47 Integrated Voltage Measurement... 14:07:56 Voltage Offset Correction: v_off_ini = 2407.547 uV, v_off_fin = 2402.382 uV 14:07:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.613 uVs 14:07:56 Integrated Voltage Measurement... 14:08:05 Voltage Offset Correction: v_off_ini = 2391.758 uV, v_off_fin = 2412.332 uV 14:08:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.383 uVs 14:08:05 Integrated Voltage Measurement... 14:08:14 Voltage Offset Correction: v_off_ini = 2409.206 uV, v_off_fin = 2390.589 uV 14:08:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.773 uVs 14:08:14 Integrated Voltage Measurement... 14:08:23 Voltage Offset Correction: v_off_ini = 2380.824 uV, v_off_fin = 2403.834 uV 14:08:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.479 uVs 14:08:25 I2Y Average and RMS of Measurements VT = -285.735 +- 9.968 uVs I2Y = -26.288 +- 0.917 uTm^2 14:08:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:08:34 Integrated Voltage Measurement... 14:08:43 Voltage Offset Correction: v_off_ini = 2437.878 uV, v_off_fin = 2436.602 uV 14:08:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.405 uVs 14:08:43 Integrated Voltage Measurement... 14:08:52 Voltage Offset Correction: v_off_ini = 2415.841 uV, v_off_fin = 2448.903 uV 14:08:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.725 uVs 14:08:52 Integrated Voltage Measurement... 14:09:01 Voltage Offset Correction: v_off_ini = 2448.142 uV, v_off_fin = 2444.078 uV 14:09:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.477 uVs 14:09:01 Integrated Voltage Measurement... 14:09:10 Voltage Offset Correction: v_off_ini = 2444.309 uV, v_off_fin = 2435.871 uV 14:09:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.769 uVs 14:09:10 Integrated Voltage Measurement... 14:09:19 Voltage Offset Correction: v_off_ini = 2446.961 uV, v_off_fin = 2431.773 uV 14:09:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.880 uVs 14:09:19 Integrated Voltage Measurement... 14:09:28 Voltage Offset Correction: v_off_ini = 2449.163 uV, v_off_fin = 2433.128 uV 14:09:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.125 uVs 14:09:33 I1X Average and RMS of Measurements VT = -73.897 +- 5.253 uVs I1X = 14.779 +- 1.051 uTm 14:09:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:09:39 Integrated Voltage Measurement... 14:09:48 Voltage Offset Correction: v_off_ini = 2429.408 uV, v_off_fin = 2427.746 uV 14:09:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.613 uVs 14:09:48 Integrated Voltage Measurement... 14:09:57 Voltage Offset Correction: v_off_ini = 2446.225 uV, v_off_fin = 2453.826 uV 14:09:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.878 uVs 14:09:57 Integrated Voltage Measurement... 14:10:06 Voltage Offset Correction: v_off_ini = 2425.022 uV, v_off_fin = 2404.712 uV 14:10:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.563 uVs 14:10:06 Integrated Voltage Measurement... 14:10:15 Voltage Offset Correction: v_off_ini = 2453.976 uV, v_off_fin = 2472.384 uV 14:10:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.750 uVs 14:10:15 Integrated Voltage Measurement... 14:10:24 Voltage Offset Correction: v_off_ini = 2442.925 uV, v_off_fin = 2437.132 uV 14:10:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.115 uVs 14:10:24 Integrated Voltage Measurement... 14:10:33 Voltage Offset Correction: v_off_ini = 2446.991 uV, v_off_fin = 2466.946 uV 14:10:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.045 uVs 14:10:37 I1Y Average and RMS of Measurements VT = -182.827 +- 6.029 uVs I1Y = -36.565 +- 1.206 uTm 14:10:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:10:45 Integrated Voltage Measurement... 14:10:54 Voltage Offset Correction: v_off_ini = 2469.123 uV, v_off_fin = 2467.321 uV 14:10:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.738 uVs 14:10:54 Integrated Voltage Measurement... 14:11:03 Voltage Offset Correction: v_off_ini = 2486.565 uV, v_off_fin = 2468.039 uV 14:11:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.216 uVs 14:11:03 Integrated Voltage Measurement... 14:11:12 Voltage Offset Correction: v_off_ini = 2465.630 uV, v_off_fin = 2474.298 uV 14:11:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.508 uVs 14:11:12 Integrated Voltage Measurement... 14:11:21 Voltage Offset Correction: v_off_ini = 2477.820 uV, v_off_fin = 2488.845 uV 14:11:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.241 uVs 14:11:21 Integrated Voltage Measurement... 14:11:30 Voltage Offset Correction: v_off_ini = 2468.232 uV, v_off_fin = 2470.673 uV 14:11:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -64.554 uVs 14:11:30 Integrated Voltage Measurement... 14:11:39 Voltage Offset Correction: v_off_ini = 2469.697 uV, v_off_fin = 2479.141 uV 14:11:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.135 uVs 14:11:42 I2X Average and RMS of Measurements VT = -78.399 +- 1.472 uVs I2X = 7.213 +- 0.135 uTm^2 14:11:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:11:49 Integrated Voltage Measurement... 14:11:58 Voltage Offset Correction: v_off_ini = 2498.818 uV, v_off_fin = 2475.722 uV 14:11:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.796 uVs 14:11:58 Integrated Voltage Measurement... 14:12:07 Voltage Offset Correction: v_off_ini = 2475.125 uV, v_off_fin = 2487.702 uV 14:12:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.926 uVs 14:12:07 Integrated Voltage Measurement... 14:12:16 Voltage Offset Correction: v_off_ini = 2459.737 uV, v_off_fin = 2461.345 uV 14:12:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.468 uVs 14:12:16 Integrated Voltage Measurement... 14:12:25 Voltage Offset Correction: v_off_ini = 2436.300 uV, v_off_fin = 2458.049 uV 14:12:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 328.945 uVs 14:12:25 Integrated Voltage Measurement... 14:12:34 Voltage Offset Correction: v_off_ini = 2471.188 uV, v_off_fin = 2466.268 uV 14:12:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.454 uVs 14:12:34 Integrated Voltage Measurement... 14:12:43 Voltage Offset Correction: v_off_ini = 2500.154 uV, v_off_fin = 2511.894 uV 14:12:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.270 uVs 14:12:46 I2Y Average and RMS of Measurements VT = -293.977 +- 15.561 uVs I2Y = -27.046 +- 1.432 uTm^2 14:12:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:55 Integrated Voltage Measurement... 14:13:04 Voltage Offset Correction: v_off_ini = 2478.922 uV, v_off_fin = 2482.547 uV 14:13:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -59.660 uVs 14:13:04 Integrated Voltage Measurement... 14:13:13 Voltage Offset Correction: v_off_ini = 2474.073 uV, v_off_fin = 2466.238 uV 14:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.614 uVs 14:13:13 Integrated Voltage Measurement... 14:13:22 Voltage Offset Correction: v_off_ini = 2480.166 uV, v_off_fin = 2458.691 uV 14:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.205 uVs 14:13:22 Integrated Voltage Measurement... 14:13:31 Voltage Offset Correction: v_off_ini = 2468.516 uV, v_off_fin = 2467.869 uV 14:13:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.254 uVs 14:13:31 Integrated Voltage Measurement... 14:13:40 Voltage Offset Correction: v_off_ini = 2462.084 uV, v_off_fin = 2471.022 uV 14:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.118 uVs 14:13:40 Integrated Voltage Measurement... 14:13:49 Voltage Offset Correction: v_off_ini = 2484.192 uV, v_off_fin = 2500.510 uV 14:13:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.627 uVs 14:13:53 I1X Average and RMS of Measurements VT = -66.080 +- 0.716 uVs I1X = 13.217 +- 0.142 uTm 14:13:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:00 Integrated Voltage Measurement... 14:14:09 Voltage Offset Correction: v_off_ini = 2478.420 uV, v_off_fin = 2488.564 uV 14:14:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.683 uVs 14:14:09 Integrated Voltage Measurement... 14:14:18 Voltage Offset Correction: v_off_ini = 2491.666 uV, v_off_fin = 2486.965 uV 14:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 195.286 uVs 14:14:18 Integrated Voltage Measurement... 14:14:27 Voltage Offset Correction: v_off_ini = 2494.797 uV, v_off_fin = 2501.517 uV 14:14:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.369 uVs 14:14:27 Integrated Voltage Measurement... 14:14:36 Voltage Offset Correction: v_off_ini = 2478.847 uV, v_off_fin = 2521.366 uV 14:14:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.203 uVs 14:14:36 Integrated Voltage Measurement... 14:14:45 Voltage Offset Correction: v_off_ini = 2506.733 uV, v_off_fin = 2489.042 uV 14:14:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.396 uVs 14:14:45 Integrated Voltage Measurement... 14:14:54 Voltage Offset Correction: v_off_ini = 2503.778 uV, v_off_fin = 2513.134 uV 14:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.388 uVs 14:14:58 I1Y Average and RMS of Measurements VT = -187.054 +- 4.207 uVs I1Y = -37.412 +- 0.841 uTm 14:15:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:06 Integrated Voltage Measurement... 14:15:15 Voltage Offset Correction: v_off_ini = 2486.618 uV, v_off_fin = 2474.046 uV 14:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.147 uVs 14:15:15 Integrated Voltage Measurement... 14:15:24 Voltage Offset Correction: v_off_ini = 2488.945 uV, v_off_fin = 2498.584 uV 14:15:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.263 uVs 14:15:24 Integrated Voltage Measurement... 14:15:33 Voltage Offset Correction: v_off_ini = 2488.741 uV, v_off_fin = 2475.860 uV 14:15:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.070 uVs 14:15:33 Integrated Voltage Measurement... 14:15:42 Voltage Offset Correction: v_off_ini = 2493.954 uV, v_off_fin = 2497.817 uV 14:15:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.671 uVs 14:15:42 Integrated Voltage Measurement... 14:15:51 Voltage Offset Correction: v_off_ini = 2473.228 uV, v_off_fin = 2475.424 uV 14:15:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.786 uVs 14:15:51 Integrated Voltage Measurement... 14:16:00 Voltage Offset Correction: v_off_ini = 2467.560 uV, v_off_fin = 2477.457 uV 14:16:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.232 uVs 14:16:02 I2X Average and RMS of Measurements VT = -69.195 +- 4.852 uVs I2X = 6.366 +- 0.447 uTm^2 14:16:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:10 Integrated Voltage Measurement... 14:16:19 Voltage Offset Correction: v_off_ini = 2442.491 uV, v_off_fin = 2449.754 uV 14:16:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.307 uVs 14:16:19 Integrated Voltage Measurement... 14:16:28 Voltage Offset Correction: v_off_ini = 2455.622 uV, v_off_fin = 2451.922 uV 14:16:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.831 uVs 14:16:28 Integrated Voltage Measurement... 14:16:37 Voltage Offset Correction: v_off_ini = 2429.184 uV, v_off_fin = 2427.380 uV 14:16:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.684 uVs 14:16:37 Integrated Voltage Measurement... 14:16:46 Voltage Offset Correction: v_off_ini = 2425.226 uV, v_off_fin = 2439.828 uV 14:16:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.790 uVs 14:16:46 Integrated Voltage Measurement... 14:16:55 Voltage Offset Correction: v_off_ini = 2441.214 uV, v_off_fin = 2419.966 uV 14:16:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.602 uVs 14:16:55 Integrated Voltage Measurement... 14:17:04 Voltage Offset Correction: v_off_ini = 2438.198 uV, v_off_fin = 2419.844 uV 14:17:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.850 uVs 14:17:06 I2Y Average and RMS of Measurements VT = -294.011 +- 8.649 uVs I2Y = -27.049 +- 0.796 uTm^2 14:17:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:17:15 Integrated Voltage Measurement... 14:17:24 Voltage Offset Correction: v_off_ini = 2400.096 uV, v_off_fin = 2404.855 uV 14:17:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -64.633 uVs 14:17:24 Integrated Voltage Measurement... 14:17:33 Voltage Offset Correction: v_off_ini = 2363.226 uV, v_off_fin = 2383.470 uV 14:17:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.681 uVs 14:17:33 Integrated Voltage Measurement... 14:17:42 Voltage Offset Correction: v_off_ini = 2393.611 uV, v_off_fin = 2381.021 uV 14:17:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.134 uVs 14:17:42 Integrated Voltage Measurement... 14:17:51 Voltage Offset Correction: v_off_ini = 2408.772 uV, v_off_fin = 2399.365 uV 14:17:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.891 uVs 14:17:51 Integrated Voltage Measurement... 14:18:00 Voltage Offset Correction: v_off_ini = 2397.983 uV, v_off_fin = 2366.033 uV 14:18:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.185 uVs 14:18:00 Integrated Voltage Measurement... 14:18:09 Voltage Offset Correction: v_off_ini = 2388.591 uV, v_off_fin = 2379.738 uV 14:18:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.260 uVs 14:18:14 I1X Average and RMS of Measurements VT = -76.298 +- 15.043 uVs I1X = 15.261 +- 3.009 uTm 14:18:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:18:20 Integrated Voltage Measurement... 14:18:29 Voltage Offset Correction: v_off_ini = 2387.716 uV, v_off_fin = 2374.286 uV 14:18:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.274 uVs 14:18:29 Integrated Voltage Measurement... 14:18:38 Voltage Offset Correction: v_off_ini = 2373.354 uV, v_off_fin = 2369.837 uV 14:18:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.589 uVs 14:18:38 Integrated Voltage Measurement... 14:18:47 Voltage Offset Correction: v_off_ini = 2370.766 uV, v_off_fin = 2375.042 uV 14:18:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.661 uVs 14:18:47 Integrated Voltage Measurement... 14:18:56 Voltage Offset Correction: v_off_ini = 2380.723 uV, v_off_fin = 2367.264 uV 14:18:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.219 uVs 14:18:56 Integrated Voltage Measurement... 14:19:05 Voltage Offset Correction: v_off_ini = 2347.744 uV, v_off_fin = 2335.191 uV 14:19:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.690 uVs 14:19:05 Integrated Voltage Measurement... 14:19:14 Voltage Offset Correction: v_off_ini = 2340.350 uV, v_off_fin = 2359.138 uV 14:19:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.014 uVs 14:19:18 I1Y Average and RMS of Measurements VT = -185.241 +- 5.026 uVs I1Y = -37.048 +- 1.005 uTm 14:19:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:19:26 Integrated Voltage Measurement... 14:19:35 Voltage Offset Correction: v_off_ini = 2325.315 uV, v_off_fin = 2344.619 uV 14:19:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.601 uVs 14:19:35 Integrated Voltage Measurement... 14:19:44 Voltage Offset Correction: v_off_ini = 2322.582 uV, v_off_fin = 2328.835 uV 14:19:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.199 uVs 14:19:44 Integrated Voltage Measurement... 14:19:53 Voltage Offset Correction: v_off_ini = 2327.739 uV, v_off_fin = 2310.093 uV 14:19:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.724 uVs 14:19:53 Integrated Voltage Measurement... 14:20:02 Voltage Offset Correction: v_off_ini = 2305.890 uV, v_off_fin = 2322.251 uV 14:20:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.397 uVs 14:20:02 Integrated Voltage Measurement... 14:20:11 Voltage Offset Correction: v_off_ini = 2298.643 uV, v_off_fin = 2291.388 uV 14:20:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -39.473 uVs 14:20:11 Integrated Voltage Measurement... 14:20:20 Voltage Offset Correction: v_off_ini = 2282.751 uV, v_off_fin = 2301.386 uV 14:20:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.958 uVs 14:20:23 I2X Average and RMS of Measurements VT = -59.225 +- 13.249 uVs I2X = 5.449 +- 1.219 uTm^2 14:20:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:20:30 Integrated Voltage Measurement... 14:20:39 Voltage Offset Correction: v_off_ini = 2278.628 uV, v_off_fin = 2277.873 uV 14:20:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.898 uVs 14:20:39 Integrated Voltage Measurement... 14:20:48 Voltage Offset Correction: v_off_ini = 2268.538 uV, v_off_fin = 2264.236 uV 14:20:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.299 uVs 14:20:48 Integrated Voltage Measurement... 14:20:57 Voltage Offset Correction: v_off_ini = 2273.449 uV, v_off_fin = 2269.909 uV 14:20:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.031 uVs 14:20:57 Integrated Voltage Measurement... 14:21:06 Voltage Offset Correction: v_off_ini = 2266.252 uV, v_off_fin = 2292.098 uV 14:21:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.408 uVs 14:21:06 Integrated Voltage Measurement... 14:21:15 Voltage Offset Correction: v_off_ini = 2267.218 uV, v_off_fin = 2263.742 uV 14:21:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.845 uVs 14:21:15 Integrated Voltage Measurement... 14:21:24 Voltage Offset Correction: v_off_ini = 2271.519 uV, v_off_fin = 2272.548 uV 14:21:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 297.503 uVs 14:21:27 I2Y Average and RMS of Measurements VT = -289.497 +- 8.920 uVs I2Y = -26.634 +- 0.820 uTm^2 14:21:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:21:36 Integrated Voltage Measurement... 14:21:45 Voltage Offset Correction: v_off_ini = 2284.940 uV, v_off_fin = 2277.395 uV 14:21:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -50.088 uVs 14:21:45 Integrated Voltage Measurement... 14:21:54 Voltage Offset Correction: v_off_ini = 2282.012 uV, v_off_fin = 2282.375 uV 14:21:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.601 uVs 14:21:54 Integrated Voltage Measurement... 14:22:03 Voltage Offset Correction: v_off_ini = 2268.325 uV, v_off_fin = 2250.872 uV 14:22:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.745 uVs 14:22:03 Integrated Voltage Measurement... 14:22:12 Voltage Offset Correction: v_off_ini = 2262.839 uV, v_off_fin = 2256.850 uV 14:22:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 46.588 uVs 14:22:12 Integrated Voltage Measurement... 14:22:21 Voltage Offset Correction: v_off_ini = 2272.194 uV, v_off_fin = 2241.288 uV 14:22:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.701 uVs 14:22:21 Integrated Voltage Measurement... 14:22:30 Voltage Offset Correction: v_off_ini = 2278.332 uV, v_off_fin = 2272.175 uV 14:22:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.186 uVs 14:22:34 I1X Average and RMS of Measurements VT = -49.985 +- 3.110 uVs I1X = 9.998 +- 0.621 uTm 14:22:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:22:41 Integrated Voltage Measurement... 14:22:50 Voltage Offset Correction: v_off_ini = 2280.133 uV, v_off_fin = 2316.823 uV 14:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.913 uVs 14:22:50 Integrated Voltage Measurement... 14:22:59 Voltage Offset Correction: v_off_ini = 2303.040 uV, v_off_fin = 2337.253 uV 14:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.532 uVs 14:22:59 Integrated Voltage Measurement... 14:23:08 Voltage Offset Correction: v_off_ini = 2301.346 uV, v_off_fin = 2303.537 uV 14:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.712 uVs 14:23:08 Integrated Voltage Measurement... 14:23:17 Voltage Offset Correction: v_off_ini = 2290.227 uV, v_off_fin = 2288.250 uV 14:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.828 uVs 14:23:17 Integrated Voltage Measurement... 14:23:26 Voltage Offset Correction: v_off_ini = 2262.526 uV, v_off_fin = 2260.511 uV 14:23:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.807 uVs 14:23:26 Integrated Voltage Measurement... 14:23:35 Voltage Offset Correction: v_off_ini = 2285.366 uV, v_off_fin = 2284.543 uV 14:23:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.738 uVs 14:23:39 I1Y Average and RMS of Measurements VT = -182.255 +- 5.738 uVs I1Y = -36.451 +- 1.148 uTm 14:23:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:23:46 Integrated Voltage Measurement... 14:23:55 Voltage Offset Correction: v_off_ini = 2295.411 uV, v_off_fin = 2295.528 uV 14:23:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.641 uVs 14:23:55 Integrated Voltage Measurement... 14:24:04 Voltage Offset Correction: v_off_ini = 2283.550 uV, v_off_fin = 2294.796 uV 14:24:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.096 uVs 14:24:05 Integrated Voltage Measurement... 14:24:13 Voltage Offset Correction: v_off_ini = 2277.685 uV, v_off_fin = 2294.251 uV 14:24:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.262 uVs 14:24:14 Integrated Voltage Measurement... 14:24:23 Voltage Offset Correction: v_off_ini = 2294.166 uV, v_off_fin = 2305.143 uV 14:24:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 47.463 uVs 14:24:23 Integrated Voltage Measurement... 14:24:32 Voltage Offset Correction: v_off_ini = 2288.732 uV, v_off_fin = 2280.016 uV 14:24:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.307 uVs 14:24:32 Integrated Voltage Measurement... 14:24:41 Voltage Offset Correction: v_off_ini = 2274.084 uV, v_off_fin = 2295.341 uV 14:24:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.990 uVs 14:24:43 I2X Average and RMS of Measurements VT = -52.793 +- 5.714 uVs I2X = 4.857 +- 0.526 uTm^2 14:24:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:24:51 Integrated Voltage Measurement... 14:25:00 Voltage Offset Correction: v_off_ini = 2305.102 uV, v_off_fin = 2285.606 uV 14:25:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.008 uVs 14:25:00 Integrated Voltage Measurement... 14:25:09 Voltage Offset Correction: v_off_ini = 2293.163 uV, v_off_fin = 2305.722 uV 14:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.662 uVs 14:25:09 Integrated Voltage Measurement... 14:25:18 Voltage Offset Correction: v_off_ini = 2326.044 uV, v_off_fin = 2305.848 uV 14:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.154 uVs 14:25:18 Integrated Voltage Measurement... 14:25:27 Voltage Offset Correction: v_off_ini = 2300.822 uV, v_off_fin = 2308.531 uV 14:25:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 353.620 uVs 14:25:27 Integrated Voltage Measurement... 14:25:36 Voltage Offset Correction: v_off_ini = 2316.499 uV, v_off_fin = 2307.998 uV 14:25:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.147 uVs 14:25:36 Integrated Voltage Measurement... 14:25:45 Voltage Offset Correction: v_off_ini = 2307.680 uV, v_off_fin = 2316.188 uV 14:25:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.580 uVs 14:25:47 I2Y Average and RMS of Measurements VT = -307.195 +- 21.861 uVs I2Y = -28.262 +- 2.011 uTm^2 14:25:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:25:59 Integrated Voltage Measurement... 14:26:08 Voltage Offset Correction: v_off_ini = 2335.207 uV, v_off_fin = 2339.304 uV 14:26:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.128 uVs 14:26:08 Integrated Voltage Measurement... 14:26:17 Voltage Offset Correction: v_off_ini = 2358.384 uV, v_off_fin = 2343.568 uV 14:26:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.472 uVs 14:26:17 Integrated Voltage Measurement... 14:26:26 Voltage Offset Correction: v_off_ini = 2339.546 uV, v_off_fin = 2322.899 uV 14:26:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.271 uVs 14:26:26 Integrated Voltage Measurement... 14:26:35 Voltage Offset Correction: v_off_ini = 2327.901 uV, v_off_fin = 2335.403 uV 14:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.802 uVs 14:26:35 Integrated Voltage Measurement... 14:26:44 Voltage Offset Correction: v_off_ini = 2359.271 uV, v_off_fin = 2342.330 uV 14:26:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -104.528 uVs 14:26:44 Integrated Voltage Measurement... 14:26:53 Voltage Offset Correction: v_off_ini = 2363.282 uV, v_off_fin = 2354.999 uV 14:26:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 50.885 uVs 14:26:57 I1X Average and RMS of Measurements VT = -69.348 +- 5.953 uVs I1X = 13.871 +- 1.192 uTm 14:27:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:27:04 Integrated Voltage Measurement... 14:27:13 Voltage Offset Correction: v_off_ini = 2348.607 uV, v_off_fin = 2347.436 uV 14:27:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.696 uVs 14:27:13 Integrated Voltage Measurement... 14:27:22 Voltage Offset Correction: v_off_ini = 2365.920 uV, v_off_fin = 2366.535 uV 14:27:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.598 uVs 14:27:22 Integrated Voltage Measurement... 14:27:31 Voltage Offset Correction: v_off_ini = 2380.704 uV, v_off_fin = 2347.614 uV 14:27:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.289 uVs 14:27:31 Integrated Voltage Measurement... 14:27:40 Voltage Offset Correction: v_off_ini = 2378.235 uV, v_off_fin = 2386.897 uV 14:27:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.015 uVs 14:27:40 Integrated Voltage Measurement... 14:27:49 Voltage Offset Correction: v_off_ini = 2415.880 uV, v_off_fin = 2382.248 uV 14:27:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.550 uVs 14:27:49 Integrated Voltage Measurement... 14:27:58 Voltage Offset Correction: v_off_ini = 2412.133 uV, v_off_fin = 2416.545 uV 14:27:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.498 uVs 14:28:02 I1Y Average and RMS of Measurements VT = -200.774 +- 12.727 uVs I1Y = -40.155 +- 2.545 uTm 14:28:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:28:07 Integrated Voltage Measurement... 14:28:16 Voltage Offset Correction: v_off_ini = 2398.533 uV, v_off_fin = 2407.165 uV 14:28:16 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -101.692 uVs 14:28:16 Integrated Voltage Measurement... 14:28:25 Voltage Offset Correction: v_off_ini = 2416.693 uV, v_off_fin = 2424.598 uV 14:28:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.286 uVs 14:28:25 Integrated Voltage Measurement... 14:28:34 Voltage Offset Correction: v_off_ini = 2375.168 uV, v_off_fin = 2391.610 uV 14:28:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.936 uVs 14:28:34 Integrated Voltage Measurement... 14:28:43 Voltage Offset Correction: v_off_ini = 2415.757 uV, v_off_fin = 2420.054 uV 14:28:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.814 uVs 14:28:43 Integrated Voltage Measurement... 14:28:52 Voltage Offset Correction: v_off_ini = 2408.286 uV, v_off_fin = 2416.072 uV 14:28:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.455 uVs 14:28:52 Integrated Voltage Measurement... 14:29:01 Voltage Offset Correction: v_off_ini = 2398.468 uV, v_off_fin = 2421.475 uV 14:29:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.141 uVs 14:29:04 I2X Average and RMS of Measurements VT = -82.387 +- 8.915 uVs I2X = 7.579 +- 0.820 uTm^2 14:29:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:29:09 Integrated Voltage Measurement... 14:29:18 Voltage Offset Correction: v_off_ini = 2398.009 uV, v_off_fin = 2391.010 uV 14:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.209 uVs 14:29:18 Integrated Voltage Measurement... 14:29:27 Voltage Offset Correction: v_off_ini = 2385.116 uV, v_off_fin = 2389.707 uV 14:29:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.172 uVs 14:29:27 Integrated Voltage Measurement... 14:29:36 Voltage Offset Correction: v_off_ini = 2390.747 uV, v_off_fin = 2409.760 uV 14:29:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.601 uVs 14:29:36 Integrated Voltage Measurement... 14:29:45 Voltage Offset Correction: v_off_ini = 2419.717 uV, v_off_fin = 2407.152 uV 14:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.589 uVs 14:29:45 Integrated Voltage Measurement... 14:29:54 Voltage Offset Correction: v_off_ini = 2418.989 uV, v_off_fin = 2404.391 uV 14:29:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.979 uVs 14:29:54 Integrated Voltage Measurement... 14:30:03 Voltage Offset Correction: v_off_ini = 2417.773 uV, v_off_fin = 2397.427 uV 14:30:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.478 uVs 14:30:05 I2Y Average and RMS of Measurements VT = -309.005 +- 7.938 uVs I2Y = -28.428 +- 0.730 uTm^2 14:30:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:30:14 Integrated Voltage Measurement... 14:30:23 Voltage Offset Correction: v_off_ini = 2417.895 uV, v_off_fin = 2408.801 uV 14:30:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.308 uVs 14:30:23 Integrated Voltage Measurement... 14:30:32 Voltage Offset Correction: v_off_ini = 2443.509 uV, v_off_fin = 2444.607 uV 14:30:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 28.470 uVs 14:30:32 Integrated Voltage Measurement... 14:30:41 Voltage Offset Correction: v_off_ini = 2436.040 uV, v_off_fin = 2405.271 uV 14:30:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.229 uVs 14:30:41 Integrated Voltage Measurement... 14:30:50 Voltage Offset Correction: v_off_ini = 2409.205 uV, v_off_fin = 2429.556 uV 14:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.119 uVs 14:30:50 Integrated Voltage Measurement... 14:30:59 Voltage Offset Correction: v_off_ini = 2433.789 uV, v_off_fin = 2420.845 uV 14:30:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.103 uVs 14:30:59 Integrated Voltage Measurement... 14:31:08 Voltage Offset Correction: v_off_ini = 2445.823 uV, v_off_fin = 2422.524 uV 14:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.868 uVs 14:31:12 I1X Average and RMS of Measurements VT = -70.516 +- 15.050 uVs I1X = 14.104 +- 3.010 uTm 14:31:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:31:19 Integrated Voltage Measurement... 14:31:28 Voltage Offset Correction: v_off_ini = 2408.976 uV, v_off_fin = 2388.587 uV 14:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.679 uVs 14:31:28 Integrated Voltage Measurement... 14:31:37 Voltage Offset Correction: v_off_ini = 2414.694 uV, v_off_fin = 2422.333 uV 14:31:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.005 uVs 14:31:37 Integrated Voltage Measurement... 14:31:46 Voltage Offset Correction: v_off_ini = 2423.910 uV, v_off_fin = 2419.456 uV 14:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.652 uVs 14:31:46 Integrated Voltage Measurement... 14:31:55 Voltage Offset Correction: v_off_ini = 2397.982 uV, v_off_fin = 2401.758 uV 14:31:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.372 uVs 14:31:55 Integrated Voltage Measurement... 14:32:04 Voltage Offset Correction: v_off_ini = 2446.736 uV, v_off_fin = 2420.741 uV 14:32:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.433 uVs 14:32:04 Integrated Voltage Measurement... 14:32:13 Voltage Offset Correction: v_off_ini = 2411.422 uV, v_off_fin = 2423.654 uV 14:32:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.817 uVs 14:32:17 I1Y Average and RMS of Measurements VT = -185.660 +- 17.488 uVs I1Y = -37.132 +- 3.498 uTm 14:32:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:32:22 Integrated Voltage Measurement... 14:32:31 Voltage Offset Correction: v_off_ini = 2385.910 uV, v_off_fin = 2403.083 uV 14:32:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.270 uVs 14:32:31 Integrated Voltage Measurement... 14:32:40 Voltage Offset Correction: v_off_ini = 2406.769 uV, v_off_fin = 2447.968 uV 14:32:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.009 uVs 14:32:40 Integrated Voltage Measurement... 14:32:49 Voltage Offset Correction: v_off_ini = 2459.423 uV, v_off_fin = 2431.160 uV 14:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.127 uVs 14:32:49 Integrated Voltage Measurement... 14:32:58 Voltage Offset Correction: v_off_ini = 2415.385 uV, v_off_fin = 2443.143 uV 14:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.994 uVs 14:32:58 Integrated Voltage Measurement... 14:33:07 Voltage Offset Correction: v_off_ini = 2429.397 uV, v_off_fin = 2385.974 uV 14:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.871 uVs 14:33:07 Integrated Voltage Measurement... 14:33:16 Voltage Offset Correction: v_off_ini = 2413.271 uV, v_off_fin = 2412.797 uV 14:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.468 uVs 14:33:18 I2X Average and RMS of Measurements VT = -76.123 +- 19.068 uVs I2X = 7.003 +- 1.754 uTm^2 14:33:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:33:24 Integrated Voltage Measurement... 14:33:33 Voltage Offset Correction: v_off_ini = 2429.386 uV, v_off_fin = 2407.260 uV 14:33:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.598 uVs 14:33:33 Integrated Voltage Measurement... 14:33:42 Voltage Offset Correction: v_off_ini = 2411.448 uV, v_off_fin = 2447.318 uV 14:33:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.796 uVs 14:33:42 Integrated Voltage Measurement... 14:33:51 Voltage Offset Correction: v_off_ini = 2435.207 uV, v_off_fin = 2433.503 uV 14:33:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.312 uVs 14:33:51 Integrated Voltage Measurement... 14:34:00 Voltage Offset Correction: v_off_ini = 2430.414 uV, v_off_fin = 2431.501 uV 14:34:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.142 uVs 14:34:00 Integrated Voltage Measurement... 14:34:09 Voltage Offset Correction: v_off_ini = 2439.615 uV, v_off_fin = 2420.139 uV 14:34:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.400 uVs 14:34:09 Integrated Voltage Measurement... 14:34:18 Voltage Offset Correction: v_off_ini = 2443.722 uV, v_off_fin = 2415.084 uV 14:34:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.234 uVs 14:34:20 I2Y Average and RMS of Measurements VT = -316.747 +- 4.262 uVs I2Y = -29.141 +- 0.392 uTm^2 14:34:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:28 Integrated Voltage Measurement... 14:34:37 Voltage Offset Correction: v_off_ini = 2406.529 uV, v_off_fin = 2412.061 uV 14:34:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -60.929 uVs 14:34:38 Integrated Voltage Measurement... 14:34:46 Voltage Offset Correction: v_off_ini = 2418.590 uV, v_off_fin = 2392.744 uV 14:34:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.506 uVs 14:34:47 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = 2410.292 uV, v_off_fin = 2389.698 uV 14:34:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.212 uVs 14:34:56 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = 2383.433 uV, v_off_fin = 2415.773 uV 14:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.618 uVs 14:35:05 Integrated Voltage Measurement... 14:35:14 Voltage Offset Correction: v_off_ini = 2395.682 uV, v_off_fin = 2432.287 uV 14:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.710 uVs 14:35:14 Integrated Voltage Measurement... 14:35:23 Voltage Offset Correction: v_off_ini = 2410.465 uV, v_off_fin = 2396.193 uV 14:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.607 uVs 14:35:27 I1X Average and RMS of Measurements VT = -70.930 +- 3.415 uVs I1X = 14.187 +- 0.682 uTm 14:35:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:34 Integrated Voltage Measurement... 14:35:42 Voltage Offset Correction: v_off_ini = 2394.460 uV, v_off_fin = 2404.116 uV 14:35:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.545 uVs 14:35:43 Integrated Voltage Measurement... 14:35:51 Voltage Offset Correction: v_off_ini = 2393.181 uV, v_off_fin = 2380.725 uV 14:35:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.148 uVs 14:35:52 Integrated Voltage Measurement... 14:36:00 Voltage Offset Correction: v_off_ini = 2375.574 uV, v_off_fin = 2374.237 uV 14:36:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.407 uVs 14:36:01 Integrated Voltage Measurement... 14:36:09 Voltage Offset Correction: v_off_ini = 2373.151 uV, v_off_fin = 2354.983 uV 14:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.483 uVs 14:36:10 Integrated Voltage Measurement... 14:36:18 Voltage Offset Correction: v_off_ini = 2344.884 uV, v_off_fin = 2359.403 uV 14:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.030 uVs 14:36:19 Integrated Voltage Measurement... 14:36:27 Voltage Offset Correction: v_off_ini = 2362.331 uV, v_off_fin = 2357.541 uV 14:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.591 uVs 14:36:32 I1Y Average and RMS of Measurements VT = -180.201 +- 5.760 uVs I1Y = -36.040 +- 1.152 uTm 14:36:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:37 Integrated Voltage Measurement... 14:36:46 Voltage Offset Correction: v_off_ini = 2348.731 uV, v_off_fin = 2333.158 uV 14:36:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.277 uVs 14:36:46 Integrated Voltage Measurement... 14:36:55 Voltage Offset Correction: v_off_ini = 2358.103 uV, v_off_fin = 2370.696 uV 14:36:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.211 uVs 14:36:55 Integrated Voltage Measurement... 14:37:04 Voltage Offset Correction: v_off_ini = 2372.962 uV, v_off_fin = 2340.601 uV 14:37:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.346 uVs 14:37:04 Integrated Voltage Measurement... 14:37:13 Voltage Offset Correction: v_off_ini = 2356.123 uV, v_off_fin = 2381.128 uV 14:37:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.183 uVs 14:37:13 Integrated Voltage Measurement... 14:37:22 Voltage Offset Correction: v_off_ini = 2365.470 uV, v_off_fin = 2374.959 uV 14:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.615 uVs 14:37:22 Integrated Voltage Measurement... 14:37:31 Voltage Offset Correction: v_off_ini = 2370.423 uV, v_off_fin = 2370.724 uV 14:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.670 uVs 14:37:33 I2X Average and RMS of Measurements VT = -70.883 +- 19.021 uVs I2X = 6.521 +- 1.750 uTm^2 14:37:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:38 Integrated Voltage Measurement... 14:37:47 Voltage Offset Correction: v_off_ini = 2366.458 uV, v_off_fin = 2381.623 uV 14:37:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.514 uVs 14:37:47 Integrated Voltage Measurement... 14:37:56 Voltage Offset Correction: v_off_ini = 2372.764 uV, v_off_fin = 2390.637 uV 14:37:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.167 uVs 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 2387.634 uV, v_off_fin = 2391.400 uV 14:38:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.831 uVs 14:38:06 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = 2373.107 uV, v_off_fin = 2363.596 uV 14:38:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.452 uVs 14:38:15 Integrated Voltage Measurement... 14:38:24 Voltage Offset Correction: v_off_ini = 2381.023 uV, v_off_fin = 2359.833 uV 14:38:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.259 uVs 14:38:24 Integrated Voltage Measurement... 14:38:33 Voltage Offset Correction: v_off_ini = 2355.591 uV, v_off_fin = 2349.429 uV 14:38:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.146 uVs 14:38:35 I2Y Average and RMS of Measurements VT = -308.395 +- 14.605 uVs I2Y = -28.372 +- 1.344 uTm^2 14:38:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:38:43 Integrated Voltage Measurement... 14:38:52 Voltage Offset Correction: v_off_ini = 2360.034 uV, v_off_fin = 2340.173 uV 14:38:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -87.664 uVs 14:38:52 Integrated Voltage Measurement... 14:39:01 Voltage Offset Correction: v_off_ini = 2342.579 uV, v_off_fin = 2344.635 uV 14:39:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.463 uVs 14:39:01 Integrated Voltage Measurement... 14:39:10 Voltage Offset Correction: v_off_ini = 2333.915 uV, v_off_fin = 2309.374 uV 14:39:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.713 uVs 14:39:10 Integrated Voltage Measurement... 14:39:19 Voltage Offset Correction: v_off_ini = 2314.899 uV, v_off_fin = 2332.853 uV 14:39:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.711 uVs 14:39:19 Integrated Voltage Measurement... 14:39:28 Voltage Offset Correction: v_off_ini = 2331.458 uV, v_off_fin = 2349.067 uV 14:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.876 uVs 14:39:28 Integrated Voltage Measurement... 14:39:37 Voltage Offset Correction: v_off_ini = 2345.014 uV, v_off_fin = 2350.046 uV 14:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.410 uVs 14:39:42 I1X Average and RMS of Measurements VT = -72.973 +- 14.921 uVs I1X = 14.595 +- 2.984 uTm 14:39:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:39:48 Integrated Voltage Measurement... 14:39:57 Voltage Offset Correction: v_off_ini = 2341.844 uV, v_off_fin = 2331.180 uV 14:39:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.544 uVs 14:39:57 Integrated Voltage Measurement... 14:40:06 Voltage Offset Correction: v_off_ini = 2306.414 uV, v_off_fin = 2323.212 uV 14:40:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.766 uVs 14:40:06 Integrated Voltage Measurement... 14:40:15 Voltage Offset Correction: v_off_ini = 2317.955 uV, v_off_fin = 2301.993 uV 14:40:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.916 uVs 14:40:15 Integrated Voltage Measurement... 14:40:24 Voltage Offset Correction: v_off_ini = 2315.006 uV, v_off_fin = 2318.056 uV 14:40:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.243 uVs 14:40:24 Integrated Voltage Measurement... 14:40:33 Voltage Offset Correction: v_off_ini = 2338.982 uV, v_off_fin = 2331.816 uV 14:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.263 uVs 14:40:33 Integrated Voltage Measurement... 14:40:42 Voltage Offset Correction: v_off_ini = 2331.835 uV, v_off_fin = 2334.431 uV 14:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.700 uVs 14:40:46 I1Y Average and RMS of Measurements VT = -187.072 +- 9.796 uVs I1Y = -37.411 +- 1.959 uTm 14:40:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:40:52 Integrated Voltage Measurement... 14:41:01 Voltage Offset Correction: v_off_ini = 2337.300 uV, v_off_fin = 2322.315 uV 14:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.255 uVs 14:41:01 Integrated Voltage Measurement... 14:41:10 Voltage Offset Correction: v_off_ini = 2328.559 uV, v_off_fin = 2333.413 uV 14:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.337 uVs 14:41:10 Integrated Voltage Measurement... 14:41:19 Voltage Offset Correction: v_off_ini = 2323.343 uV, v_off_fin = 2324.873 uV 14:41:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.486 uVs 14:41:19 Integrated Voltage Measurement... 14:41:28 Voltage Offset Correction: v_off_ini = 2352.213 uV, v_off_fin = 2366.877 uV 14:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.543 uVs 14:41:28 Integrated Voltage Measurement... 14:41:37 Voltage Offset Correction: v_off_ini = 2338.638 uV, v_off_fin = 2356.920 uV 14:41:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.272 uVs 14:41:37 Integrated Voltage Measurement... 14:41:46 Voltage Offset Correction: v_off_ini = 2345.821 uV, v_off_fin = 2381.010 uV 14:41:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.802 uVs 14:41:48 I2X Average and RMS of Measurements VT = -74.616 +- 7.754 uVs I2X = 6.865 +- 0.713 uTm^2 14:41:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:41:53 Integrated Voltage Measurement... 14:42:02 Voltage Offset Correction: v_off_ini = 2356.928 uV, v_off_fin = 2326.429 uV 14:42:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.790 uVs 14:42:02 Integrated Voltage Measurement... 14:42:11 Voltage Offset Correction: v_off_ini = 2331.569 uV, v_off_fin = 2334.786 uV 14:42:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.097 uVs 14:42:11 Integrated Voltage Measurement... 14:42:20 Voltage Offset Correction: v_off_ini = 2307.014 uV, v_off_fin = 2330.624 uV 14:42:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.766 uVs 14:42:20 Integrated Voltage Measurement... 14:42:29 Voltage Offset Correction: v_off_ini = 2344.270 uV, v_off_fin = 2359.865 uV 14:42:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.209 uVs 14:42:29 Integrated Voltage Measurement... 14:42:38 Voltage Offset Correction: v_off_ini = 2356.433 uV, v_off_fin = 2340.909 uV 14:42:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.818 uVs 14:42:38 Integrated Voltage Measurement... 14:42:47 Voltage Offset Correction: v_off_ini = 2354.521 uV, v_off_fin = 2343.221 uV 14:42:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.651 uVs 14:42:50 I2Y Average and RMS of Measurements VT = -280.722 +- 9.959 uVs I2Y = -25.826 +- 0.916 uTm^2 14:42:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:42:58 Integrated Voltage Measurement... 14:43:07 Voltage Offset Correction: v_off_ini = 2386.959 uV, v_off_fin = 2379.657 uV 14:43:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.017 uVs 14:43:07 Integrated Voltage Measurement... 14:43:16 Voltage Offset Correction: v_off_ini = 2363.486 uV, v_off_fin = 2354.641 uV 14:43:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.182 uVs 14:43:16 Integrated Voltage Measurement... 14:43:25 Voltage Offset Correction: v_off_ini = 2357.231 uV, v_off_fin = 2367.187 uV 14:43:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.219 uVs 14:43:25 Integrated Voltage Measurement... 14:43:34 Voltage Offset Correction: v_off_ini = 2381.778 uV, v_off_fin = 2377.407 uV 14:43:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.965 uVs 14:43:34 Integrated Voltage Measurement... 14:43:43 Voltage Offset Correction: v_off_ini = 2367.526 uV, v_off_fin = 2346.690 uV 14:43:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.556 uVs 14:43:43 Integrated Voltage Measurement... 14:43:52 Voltage Offset Correction: v_off_ini = 2360.920 uV, v_off_fin = 2362.829 uV 14:43:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 65.270 uVs 14:43:56 I1X Average and RMS of Measurements VT = -76.035 +- 12.089 uVs I1X = 15.207 +- 2.418 uTm 14:43:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:44:03 Integrated Voltage Measurement... 14:44:12 Voltage Offset Correction: v_off_ini = 2346.171 uV, v_off_fin = 2341.051 uV 14:44:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -154.531 uVs 14:44:12 Integrated Voltage Measurement... 14:44:21 Voltage Offset Correction: v_off_ini = 2344.704 uV, v_off_fin = 2351.638 uV 14:44:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.397 uVs 14:44:21 Integrated Voltage Measurement... 14:44:30 Voltage Offset Correction: v_off_ini = 2362.497 uV, v_off_fin = 2344.134 uV 14:44:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.398 uVs 14:44:30 Integrated Voltage Measurement... 14:44:39 Voltage Offset Correction: v_off_ini = 2345.728 uV, v_off_fin = 2340.985 uV 14:44:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.051 uVs 14:44:39 Integrated Voltage Measurement... 14:44:48 Voltage Offset Correction: v_off_ini = 2334.409 uV, v_off_fin = 2326.755 uV 14:44:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.480 uVs 14:44:48 Integrated Voltage Measurement... 14:44:57 Voltage Offset Correction: v_off_ini = 2356.250 uV, v_off_fin = 2351.020 uV 14:44:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 156.442 uVs 14:45:01 I1Y Average and RMS of Measurements VT = -175.716 +- 4.563 uVs I1Y = -35.141 +- 0.913 uTm 14:45:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:45:06 Integrated Voltage Measurement... 14:45:15 Voltage Offset Correction: v_off_ini = 2334.301 uV, v_off_fin = 2349.990 uV 14:45:15 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -34.062 uVs 14:45:15 Integrated Voltage Measurement... 14:45:24 Voltage Offset Correction: v_off_ini = 2363.338 uV, v_off_fin = 2358.706 uV 14:45:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.436 uVs 14:45:24 Integrated Voltage Measurement... 14:45:33 Voltage Offset Correction: v_off_ini = 2355.232 uV, v_off_fin = 2350.021 uV 14:45:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.068 uVs 14:45:33 Integrated Voltage Measurement... 14:45:42 Voltage Offset Correction: v_off_ini = 2370.944 uV, v_off_fin = 2361.646 uV 14:45:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.397 uVs 14:45:42 Integrated Voltage Measurement... 14:45:51 Voltage Offset Correction: v_off_ini = 2355.799 uV, v_off_fin = 2333.188 uV 14:45:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.149 uVs 14:45:51 Integrated Voltage Measurement... 14:46:00 Voltage Offset Correction: v_off_ini = 2344.535 uV, v_off_fin = 2362.334 uV 14:46:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.940 uVs 14:46:03 I2X Average and RMS of Measurements VT = -62.842 +- 15.389 uVs I2X = 5.782 +- 1.416 uTm^2 14:46:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:46:08 Integrated Voltage Measurement... 14:46:17 Voltage Offset Correction: v_off_ini = 2346.795 uV, v_off_fin = 2335.106 uV 14:46:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.911 uVs 14:46:17 Integrated Voltage Measurement... 14:46:26 Voltage Offset Correction: v_off_ini = 2304.809 uV, v_off_fin = 2317.310 uV 14:46:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.748 uVs 14:46:26 Integrated Voltage Measurement... 14:46:35 Voltage Offset Correction: v_off_ini = 2336.257 uV, v_off_fin = 2352.876 uV 14:46:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -290.530 uVs 14:46:35 Integrated Voltage Measurement... 14:46:44 Voltage Offset Correction: v_off_ini = 2340.544 uV, v_off_fin = 2304.017 uV 14:46:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.486 uVs 14:46:44 Integrated Voltage Measurement... 14:46:53 Voltage Offset Correction: v_off_ini = 2306.453 uV, v_off_fin = 2309.477 uV 14:46:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.869 uVs 14:46:53 Integrated Voltage Measurement... 14:47:02 Voltage Offset Correction: v_off_ini = 2283.512 uV, v_off_fin = 2278.364 uV 14:47:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.492 uVs 14:47:05 I2Y Average and RMS of Measurements VT = -291.173 +- 6.830 uVs I2Y = -26.788 +- 0.628 uTm^2 14:47:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:47:26 Integrated Voltage Measurement... 14:47:35 Voltage Offset Correction: v_off_ini = 2308.529 uV, v_off_fin = 2310.329 uV 14:47:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -105.733 uVs 14:47:35 Integrated Voltage Measurement... 14:47:44 Voltage Offset Correction: v_off_ini = 2303.696 uV, v_off_fin = 2291.718 uV 14:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.528 uVs 14:47:44 Integrated Voltage Measurement... 14:47:53 Voltage Offset Correction: v_off_ini = 2318.720 uV, v_off_fin = 2317.694 uV 14:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.193 uVs 14:47:53 Integrated Voltage Measurement... 14:48:02 Voltage Offset Correction: v_off_ini = 2323.129 uV, v_off_fin = 2333.938 uV 14:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.391 uVs 14:48:02 Integrated Voltage Measurement... 14:48:11 Voltage Offset Correction: v_off_ini = 2303.307 uV, v_off_fin = 2302.560 uV 14:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.865 uVs 14:48:11 Integrated Voltage Measurement... 14:48:20 Voltage Offset Correction: v_off_ini = 2309.528 uV, v_off_fin = 2315.214 uV 14:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.050 uVs 14:48:24 I1X Average and RMS of Measurements VT = -99.793 +- 10.518 uVs I1X = 19.959 +- 2.105 uTm 14:48:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:48:31 Integrated Voltage Measurement... 14:48:40 Voltage Offset Correction: v_off_ini = 2327.462 uV, v_off_fin = 2320.282 uV 14:48:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.612 uVs 14:48:40 Integrated Voltage Measurement... 14:48:49 Voltage Offset Correction: v_off_ini = 2338.274 uV, v_off_fin = 2339.290 uV 14:48:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.074 uVs 14:48:49 Integrated Voltage Measurement... 14:48:58 Voltage Offset Correction: v_off_ini = 2308.154 uV, v_off_fin = 2322.837 uV 14:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.325 uVs 14:48:58 Integrated Voltage Measurement... 14:49:07 Voltage Offset Correction: v_off_ini = 2324.612 uV, v_off_fin = 2338.541 uV 14:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.942 uVs 14:49:07 Integrated Voltage Measurement... 14:49:16 Voltage Offset Correction: v_off_ini = 2335.282 uV, v_off_fin = 2328.479 uV 14:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.717 uVs 14:49:16 Integrated Voltage Measurement... 14:49:25 Voltage Offset Correction: v_off_ini = 2341.306 uV, v_off_fin = 2329.942 uV 14:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.679 uVs 14:49:29 I1Y Average and RMS of Measurements VT = -181.392 +- 1.944 uVs I1Y = -36.278 +- 0.389 uTm 14:49:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:49:37 Integrated Voltage Measurement... 14:49:46 Voltage Offset Correction: v_off_ini = 2291.070 uV, v_off_fin = 2282.716 uV 14:49:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.741 uVs 14:49:46 Integrated Voltage Measurement... 14:49:55 Voltage Offset Correction: v_off_ini = 2303.364 uV, v_off_fin = 2339.580 uV 14:49:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.987 uVs 14:49:55 Integrated Voltage Measurement... 14:50:04 Voltage Offset Correction: v_off_ini = 2300.380 uV, v_off_fin = 2317.225 uV 14:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.565 uVs 14:50:04 Integrated Voltage Measurement... 14:50:13 Voltage Offset Correction: v_off_ini = 2354.624 uV, v_off_fin = 2350.356 uV 14:50:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.122 uVs 14:50:13 Integrated Voltage Measurement... 14:50:22 Voltage Offset Correction: v_off_ini = 2331.479 uV, v_off_fin = 2319.465 uV 14:50:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.429 uVs 14:50:22 Integrated Voltage Measurement... 14:50:31 Voltage Offset Correction: v_off_ini = 2324.788 uV, v_off_fin = 2331.434 uV 14:50:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.002 uVs 14:50:33 I2X Average and RMS of Measurements VT = -102.975 +- 2.499 uVs I2X = 9.474 +- 0.230 uTm^2 14:50:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:50:41 Integrated Voltage Measurement... 14:50:50 Voltage Offset Correction: v_off_ini = 2334.585 uV, v_off_fin = 2339.574 uV 14:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.104 uVs 14:50:50 Integrated Voltage Measurement... 14:50:59 Voltage Offset Correction: v_off_ini = 2334.723 uV, v_off_fin = 2330.101 uV 14:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.931 uVs 14:50:59 Integrated Voltage Measurement... 14:51:08 Voltage Offset Correction: v_off_ini = 2323.433 uV, v_off_fin = 2354.969 uV 14:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.938 uVs 14:51:08 Integrated Voltage Measurement... 14:51:17 Voltage Offset Correction: v_off_ini = 2323.687 uV, v_off_fin = 2315.859 uV 14:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.405 uVs 14:51:17 Integrated Voltage Measurement... 14:51:26 Voltage Offset Correction: v_off_ini = 2296.225 uV, v_off_fin = 2294.154 uV 14:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.911 uVs 14:51:26 Integrated Voltage Measurement... 14:51:35 Voltage Offset Correction: v_off_ini = 2296.198 uV, v_off_fin = 2307.536 uV 14:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.962 uVs 14:51:38 I2Y Average and RMS of Measurements VT = -291.709 +- 10.192 uVs I2Y = -26.837 +- 0.938 uTm^2 14:51:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:51:46 Integrated Voltage Measurement... 14:51:55 Voltage Offset Correction: v_off_ini = 2286.968 uV, v_off_fin = 2296.706 uV 14:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.433 uVs 14:51:55 Integrated Voltage Measurement... 14:52:04 Voltage Offset Correction: v_off_ini = 2313.890 uV, v_off_fin = 2308.062 uV 14:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.629 uVs 14:52:04 Integrated Voltage Measurement... 14:52:13 Voltage Offset Correction: v_off_ini = 2317.554 uV, v_off_fin = 2302.803 uV 14:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.693 uVs 14:52:14 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 2324.548 uV, v_off_fin = 2328.509 uV 14:52:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.670 uVs 14:52:23 Integrated Voltage Measurement... 14:52:31 Voltage Offset Correction: v_off_ini = 2309.470 uV, v_off_fin = 2328.859 uV 14:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.483 uVs 14:52:32 Integrated Voltage Measurement... 14:52:40 Voltage Offset Correction: v_off_ini = 2332.027 uV, v_off_fin = 2350.112 uV 14:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.470 uVs 14:52:45 I1X Average and RMS of Measurements VT = -82.230 +- 10.243 uVs I1X = 16.446 +- 2.049 uTm 14:52:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:52:51 Integrated Voltage Measurement... 14:53:00 Voltage Offset Correction: v_off_ini = 2320.373 uV, v_off_fin = 2303.649 uV 14:53:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.760 uVs 14:53:00 Integrated Voltage Measurement... 14:53:09 Voltage Offset Correction: v_off_ini = 2335.345 uV, v_off_fin = 2339.251 uV 14:53:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.353 uVs 14:53:09 Integrated Voltage Measurement... 14:53:18 Voltage Offset Correction: v_off_ini = 2319.878 uV, v_off_fin = 2311.458 uV 14:53:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.058 uVs 14:53:18 Integrated Voltage Measurement... 14:53:27 Voltage Offset Correction: v_off_ini = 2311.180 uV, v_off_fin = 2316.848 uV 14:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.037 uVs 14:53:27 Integrated Voltage Measurement... 14:53:36 Voltage Offset Correction: v_off_ini = 2322.008 uV, v_off_fin = 2319.819 uV 14:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.459 uVs 14:53:36 Integrated Voltage Measurement... 14:53:45 Voltage Offset Correction: v_off_ini = 2328.066 uV, v_off_fin = 2331.603 uV 14:53:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.996 uVs 14:53:50 I1Y Average and RMS of Measurements VT = -173.110 +- 2.614 uVs I1Y = -34.622 +- 0.523 uTm 14:53:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:53:57 Integrated Voltage Measurement... 14:54:06 Voltage Offset Correction: v_off_ini = 2325.674 uV, v_off_fin = 2315.936 uV 14:54:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -103.033 uVs 14:54:06 Integrated Voltage Measurement... 14:54:15 Voltage Offset Correction: v_off_ini = 2325.120 uV, v_off_fin = 2339.102 uV 14:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.197 uVs 14:54:15 Integrated Voltage Measurement... 14:54:24 Voltage Offset Correction: v_off_ini = 2311.483 uV, v_off_fin = 2313.546 uV 14:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.060 uVs 14:54:24 Integrated Voltage Measurement... 14:54:33 Voltage Offset Correction: v_off_ini = 2321.542 uV, v_off_fin = 2327.560 uV 14:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.510 uVs 14:54:33 Integrated Voltage Measurement... 14:54:42 Voltage Offset Correction: v_off_ini = 2319.347 uV, v_off_fin = 2322.403 uV 14:54:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.356 uVs 14:54:42 Integrated Voltage Measurement... 14:54:51 Voltage Offset Correction: v_off_ini = 2329.547 uV, v_off_fin = 2335.779 uV 14:54:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.356 uVs 14:54:54 I2X Average and RMS of Measurements VT = -95.919 +- 2.806 uVs I2X = 8.825 +- 0.258 uTm^2 14:54:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:55:01 Integrated Voltage Measurement... 14:55:10 Voltage Offset Correction: v_off_ini = 2323.986 uV, v_off_fin = 2340.154 uV 14:55:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.506 uVs 14:55:11 Integrated Voltage Measurement... 14:55:20 Voltage Offset Correction: v_off_ini = 2318.506 uV, v_off_fin = 2333.897 uV 14:55:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.576 uVs 14:55:20 Integrated Voltage Measurement... 14:55:29 Voltage Offset Correction: v_off_ini = 2334.019 uV, v_off_fin = 2305.835 uV 14:55:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.896 uVs 14:55:29 Integrated Voltage Measurement... 14:55:38 Voltage Offset Correction: v_off_ini = 2323.733 uV, v_off_fin = 2314.662 uV 14:55:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.967 uVs 14:55:38 Integrated Voltage Measurement... 14:55:47 Voltage Offset Correction: v_off_ini = 2310.646 uV, v_off_fin = 2313.475 uV 14:55:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.168 uVs 14:55:47 Integrated Voltage Measurement... 14:55:56 Voltage Offset Correction: v_off_ini = 2327.008 uV, v_off_fin = 2312.272 uV 14:55:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.083 uVs 14:55:58 I2Y Average and RMS of Measurements VT = -285.532 +- 7.681 uVs I2Y = -26.269 +- 0.707 uTm^2 14:56:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:07 Integrated Voltage Measurement... 14:56:16 Voltage Offset Correction: v_off_ini = 2323.092 uV, v_off_fin = 2306.461 uV 14:56:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.013 uVs 14:56:16 Integrated Voltage Measurement... 14:56:25 Voltage Offset Correction: v_off_ini = 2316.677 uV, v_off_fin = 2316.465 uV 14:56:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.174 uVs 14:56:25 Integrated Voltage Measurement... 14:56:34 Voltage Offset Correction: v_off_ini = 2308.450 uV, v_off_fin = 2319.190 uV 14:56:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.927 uVs 14:56:34 Integrated Voltage Measurement... 14:56:43 Voltage Offset Correction: v_off_ini = 2326.644 uV, v_off_fin = 2310.571 uV 14:56:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.192 uVs 14:56:43 Integrated Voltage Measurement... 14:56:52 Voltage Offset Correction: v_off_ini = 2299.134 uV, v_off_fin = 2295.836 uV 14:56:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.423 uVs 14:56:52 Integrated Voltage Measurement... 14:57:01 Voltage Offset Correction: v_off_ini = 2300.980 uV, v_off_fin = 2303.924 uV 14:57:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.310 uVs 14:57:05 I1X Average and RMS of Measurements VT = -65.673 +- 3.563 uVs I1X = 13.135 +- 0.713 uTm 14:57:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:12 Integrated Voltage Measurement... 14:57:21 Voltage Offset Correction: v_off_ini = 2328.197 uV, v_off_fin = 2312.903 uV 14:57:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.215 uVs 14:57:21 Integrated Voltage Measurement... 14:57:30 Voltage Offset Correction: v_off_ini = 2325.614 uV, v_off_fin = 2348.630 uV 14:57:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.938 uVs 14:57:30 Integrated Voltage Measurement... 14:57:39 Voltage Offset Correction: v_off_ini = 2300.430 uV, v_off_fin = 2304.993 uV 14:57:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.290 uVs 14:57:39 Integrated Voltage Measurement... 14:57:48 Voltage Offset Correction: v_off_ini = 2305.141 uV, v_off_fin = 2316.877 uV 14:57:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.352 uVs 14:57:48 Integrated Voltage Measurement... 14:57:57 Voltage Offset Correction: v_off_ini = 2293.803 uV, v_off_fin = 2302.748 uV 14:57:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.291 uVs 14:57:57 Integrated Voltage Measurement... 14:58:06 Voltage Offset Correction: v_off_ini = 2308.575 uV, v_off_fin = 2286.523 uV 14:58:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.631 uVs 14:58:10 I1Y Average and RMS of Measurements VT = -182.286 +- 0.592 uVs I1Y = -36.457 +- 0.118 uTm 14:58:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:18 Integrated Voltage Measurement... 14:58:27 Voltage Offset Correction: v_off_ini = 2301.160 uV, v_off_fin = 2275.582 uV 14:58:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.108 uVs 14:58:27 Integrated Voltage Measurement... 14:58:36 Voltage Offset Correction: v_off_ini = 2305.357 uV, v_off_fin = 2310.489 uV 14:58:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.312 uVs 14:58:36 Integrated Voltage Measurement... 14:58:45 Voltage Offset Correction: v_off_ini = 2299.274 uV, v_off_fin = 2296.681 uV 14:58:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.843 uVs 14:58:45 Integrated Voltage Measurement... 14:58:54 Voltage Offset Correction: v_off_ini = 2324.906 uV, v_off_fin = 2341.429 uV 14:58:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.515 uVs 14:58:54 Integrated Voltage Measurement... 14:59:03 Voltage Offset Correction: v_off_ini = 2316.026 uV, v_off_fin = 2315.287 uV 14:59:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.228 uVs 14:59:03 Integrated Voltage Measurement... 14:59:12 Voltage Offset Correction: v_off_ini = 2329.262 uV, v_off_fin = 2338.128 uV 14:59:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.000 uVs 14:59:14 I2X Average and RMS of Measurements VT = -74.001 +- 2.319 uVs I2X = 6.808 +- 0.213 uTm^2 14:59:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:22 Integrated Voltage Measurement... 14:59:31 Voltage Offset Correction: v_off_ini = 2303.646 uV, v_off_fin = 2309.368 uV 14:59:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.611 uVs 14:59:31 Integrated Voltage Measurement... 14:59:40 Voltage Offset Correction: v_off_ini = 2325.119 uV, v_off_fin = 2310.908 uV 14:59:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.553 uVs 14:59:40 Integrated Voltage Measurement... 14:59:49 Voltage Offset Correction: v_off_ini = 2297.968 uV, v_off_fin = 2300.700 uV 14:59:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.705 uVs 14:59:49 Integrated Voltage Measurement... 14:59:58 Voltage Offset Correction: v_off_ini = 2303.166 uV, v_off_fin = 2295.197 uV 14:59:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.130 uVs 14:59:58 Integrated Voltage Measurement... 15:00:07 Voltage Offset Correction: v_off_ini = 2298.628 uV, v_off_fin = 2324.692 uV 15:00:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.426 uVs 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 2317.444 uV, v_off_fin = 2329.871 uV 15:00:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.695 uVs 15:00:18 I2Y Average and RMS of Measurements VT = -287.853 +- 21.764 uVs I2Y = -26.483 +- 2.002 uTm^2 15:00:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:00:27 Integrated Voltage Measurement... 15:00:36 Voltage Offset Correction: v_off_ini = 2326.579 uV, v_off_fin = 2319.031 uV 15:00:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.305 uVs 15:00:36 Integrated Voltage Measurement... 15:00:45 Voltage Offset Correction: v_off_ini = 2326.472 uV, v_off_fin = 2317.098 uV 15:00:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.957 uVs 15:00:45 Integrated Voltage Measurement... 15:00:54 Voltage Offset Correction: v_off_ini = 2311.136 uV, v_off_fin = 2289.862 uV 15:00:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.614 uVs 15:00:54 Integrated Voltage Measurement... 15:01:03 Voltage Offset Correction: v_off_ini = 2308.252 uV, v_off_fin = 2300.084 uV 15:01:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.564 uVs 15:01:03 Integrated Voltage Measurement... 15:01:12 Voltage Offset Correction: v_off_ini = 2298.018 uV, v_off_fin = 2283.239 uV 15:01:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.548 uVs 15:01:12 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 2300.626 uV, v_off_fin = 2310.099 uV 15:01:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.140 uVs 15:01:26 I1X Average and RMS of Measurements VT = -60.521 +- 2.551 uVs I1X = 12.105 +- 0.510 uTm 15:01:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:01:32 Integrated Voltage Measurement... 15:01:41 Voltage Offset Correction: v_off_ini = 2293.221 uV, v_off_fin = 2296.179 uV 15:01:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.357 uVs 15:01:41 Integrated Voltage Measurement... 15:01:50 Voltage Offset Correction: v_off_ini = 2293.400 uV, v_off_fin = 2282.927 uV 15:01:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.704 uVs 15:01:50 Integrated Voltage Measurement... 15:01:59 Voltage Offset Correction: v_off_ini = 2287.364 uV, v_off_fin = 2290.247 uV 15:01:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.028 uVs 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 2293.686 uV, v_off_fin = 2298.110 uV 15:02:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.779 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 2320.379 uV, v_off_fin = 2303.751 uV 15:02:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.635 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 2325.297 uV, v_off_fin = 2305.827 uV 15:02:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.400 uVs 15:02:30 I1Y Average and RMS of Measurements VT = -175.650 +- 16.741 uVs I1Y = -35.130 +- 3.348 uTm 15:02:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:02:38 Integrated Voltage Measurement... 15:02:47 Voltage Offset Correction: v_off_ini = 2298.192 uV, v_off_fin = 2282.759 uV 15:02:47 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -70.445 uVs 15:02:47 Integrated Voltage Measurement... 15:02:56 Voltage Offset Correction: v_off_ini = 2305.446 uV, v_off_fin = 2294.660 uV 15:02:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.620 uVs 15:02:56 Integrated Voltage Measurement... 15:03:05 Voltage Offset Correction: v_off_ini = 2291.779 uV, v_off_fin = 2294.033 uV 15:03:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.916 uVs 15:03:05 Integrated Voltage Measurement... 15:03:14 Voltage Offset Correction: v_off_ini = 2291.217 uV, v_off_fin = 2290.886 uV 15:03:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.572 uVs 15:03:14 Integrated Voltage Measurement... 15:03:23 Voltage Offset Correction: v_off_ini = 2290.713 uV, v_off_fin = 2268.344 uV 15:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.529 uVs 15:03:23 Integrated Voltage Measurement... 15:03:32 Voltage Offset Correction: v_off_ini = 2300.065 uV, v_off_fin = 2309.109 uV 15:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.855 uVs 15:03:35 I2X Average and RMS of Measurements VT = -64.656 +- 10.282 uVs I2X = 5.948 +- 0.946 uTm^2 15:03:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:03:42 Integrated Voltage Measurement... 15:03:51 Voltage Offset Correction: v_off_ini = 2285.085 uV, v_off_fin = 2296.972 uV 15:03:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.045 uVs 15:03:51 Integrated Voltage Measurement... 15:04:00 Voltage Offset Correction: v_off_ini = 2303.150 uV, v_off_fin = 2299.837 uV 15:04:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.399 uVs 15:04:00 Integrated Voltage Measurement... 15:04:09 Voltage Offset Correction: v_off_ini = 2303.065 uV, v_off_fin = 2309.024 uV 15:04:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.676 uVs 15:04:09 Integrated Voltage Measurement... 15:04:18 Voltage Offset Correction: v_off_ini = 2295.095 uV, v_off_fin = 2288.261 uV 15:04:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.876 uVs 15:04:19 Integrated Voltage Measurement... 15:04:27 Voltage Offset Correction: v_off_ini = 2306.956 uV, v_off_fin = 2271.623 uV 15:04:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.419 uVs 15:04:28 Integrated Voltage Measurement... 15:04:37 Voltage Offset Correction: v_off_ini = 2280.477 uV, v_off_fin = 2299.932 uV 15:04:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.386 uVs 15:04:39 I2Y Average and RMS of Measurements VT = -277.967 +- 6.800 uVs I2Y = -25.573 +- 0.626 uTm^2 15:04:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:04:48 Integrated Voltage Measurement... 15:04:57 Voltage Offset Correction: v_off_ini = 2295.641 uV, v_off_fin = 2306.003 uV 15:04:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.615 uVs 15:04:57 Integrated Voltage Measurement... 15:05:06 Voltage Offset Correction: v_off_ini = 2310.073 uV, v_off_fin = 2329.036 uV 15:05:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.102 uVs 15:05:06 Integrated Voltage Measurement... 15:05:15 Voltage Offset Correction: v_off_ini = 2295.261 uV, v_off_fin = 2294.775 uV 15:05:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.069 uVs 15:05:15 Integrated Voltage Measurement... 15:05:24 Voltage Offset Correction: v_off_ini = 2293.470 uV, v_off_fin = 2304.665 uV 15:05:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.933 uVs 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 2303.848 uV, v_off_fin = 2293.504 uV 15:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.277 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 2323.530 uV, v_off_fin = 2261.279 uV 15:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.403 uVs 15:05:46 I1X Average and RMS of Measurements VT = -73.233 +- 21.072 uVs I1X = 14.647 +- 4.214 uTm 15:05:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:05:53 Integrated Voltage Measurement... 15:06:02 Voltage Offset Correction: v_off_ini = 2312.564 uV, v_off_fin = 2293.970 uV 15:06:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.846 uVs 15:06:02 Integrated Voltage Measurement... 15:06:11 Voltage Offset Correction: v_off_ini = 2347.915 uV, v_off_fin = 2346.113 uV 15:06:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.951 uVs 15:06:11 Integrated Voltage Measurement... 15:06:20 Voltage Offset Correction: v_off_ini = 2358.213 uV, v_off_fin = 2331.734 uV 15:06:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.527 uVs 15:06:20 Integrated Voltage Measurement... 15:06:29 Voltage Offset Correction: v_off_ini = 2322.079 uV, v_off_fin = 2349.471 uV 15:06:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.412 uVs 15:06:29 Integrated Voltage Measurement... 15:06:38 Voltage Offset Correction: v_off_ini = 2325.484 uV, v_off_fin = 2306.535 uV 15:06:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.845 uVs 15:06:38 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 2322.151 uV, v_off_fin = 2337.823 uV 15:06:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.271 uVs 15:06:51 I1Y Average and RMS of Measurements VT = -169.475 +- 2.923 uVs I1Y = -33.895 +- 0.585 uTm 15:06:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:06:59 Integrated Voltage Measurement... 15:07:08 Voltage Offset Correction: v_off_ini = 2320.559 uV, v_off_fin = 2332.466 uV 15:07:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.175 uVs 15:07:08 Integrated Voltage Measurement... 15:07:17 Voltage Offset Correction: v_off_ini = 2317.258 uV, v_off_fin = 2317.518 uV 15:07:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.916 uVs 15:07:17 Integrated Voltage Measurement... 15:07:26 Voltage Offset Correction: v_off_ini = 2312.565 uV, v_off_fin = 2301.637 uV 15:07:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.513 uVs 15:07:26 Integrated Voltage Measurement... 15:07:35 Voltage Offset Correction: v_off_ini = 2299.780 uV, v_off_fin = 2295.749 uV 15:07:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.811 uVs 15:07:35 Integrated Voltage Measurement... 15:07:44 Voltage Offset Correction: v_off_ini = 2279.165 uV, v_off_fin = 2275.716 uV 15:07:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.689 uVs 15:07:44 Integrated Voltage Measurement... 15:07:53 Voltage Offset Correction: v_off_ini = 2291.610 uV, v_off_fin = 2311.867 uV 15:07:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.029 uVs 15:07:55 I2X Average and RMS of Measurements VT = -52.855 +- 9.157 uVs I2X = 4.863 +- 0.842 uTm^2 15:08:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 2317.815 uV, v_off_fin = 2335.481 uV 15:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.432 uVs 15:08:12 Integrated Voltage Measurement... 15:08:21 Voltage Offset Correction: v_off_ini = 2312.930 uV, v_off_fin = 2345.541 uV 15:08:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 247.831 uVs 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 2307.070 uV, v_off_fin = 2308.763 uV 15:08:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.218 uVs 15:08:30 Integrated Voltage Measurement... 15:08:39 Voltage Offset Correction: v_off_ini = 2324.473 uV, v_off_fin = 2300.443 uV 15:08:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.079 uVs 15:08:39 Integrated Voltage Measurement... 15:08:48 Voltage Offset Correction: v_off_ini = 2308.948 uV, v_off_fin = 2304.764 uV 15:08:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.400 uVs 15:08:48 Integrated Voltage Measurement... 15:08:57 Voltage Offset Correction: v_off_ini = 2285.236 uV, v_off_fin = 2311.727 uV 15:08:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 342.142 uVs 15:08:59 I2Y Average and RMS of Measurements VT = -294.850 +- 31.506 uVs I2Y = -27.127 +- 2.898 uTm^2 15:09:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:09:11 Integrated Voltage Measurement... 15:09:20 Voltage Offset Correction: v_off_ini = 2318.950 uV, v_off_fin = 2308.666 uV 15:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.954 uVs 15:09:20 Integrated Voltage Measurement... 15:09:29 Voltage Offset Correction: v_off_ini = 2314.711 uV, v_off_fin = 2319.827 uV 15:09:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.308 uVs 15:09:29 Integrated Voltage Measurement... 15:09:38 Voltage Offset Correction: v_off_ini = 2322.001 uV, v_off_fin = 2307.243 uV 15:09:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.841 uVs 15:09:38 Integrated Voltage Measurement... 15:09:47 Voltage Offset Correction: v_off_ini = 2308.848 uV, v_off_fin = 2313.646 uV 15:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.909 uVs 15:09:47 Integrated Voltage Measurement... 15:09:56 Voltage Offset Correction: v_off_ini = 2329.110 uV, v_off_fin = 2302.081 uV 15:09:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.853 uVs 15:09:56 Integrated Voltage Measurement... 15:10:05 Voltage Offset Correction: v_off_ini = 2324.665 uV, v_off_fin = 2336.061 uV 15:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 76.558 uVs 15:10:10 I1X Average and RMS of Measurements VT = -79.904 +- 14.069 uVs I1X = 15.982 +- 2.815 uTm 15:10:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:10:16 Integrated Voltage Measurement... 15:10:25 Voltage Offset Correction: v_off_ini = 2347.160 uV, v_off_fin = 2340.515 uV 15:10:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.540 uVs 15:10:25 Integrated Voltage Measurement... 15:10:34 Voltage Offset Correction: v_off_ini = 2344.498 uV, v_off_fin = 2328.607 uV 15:10:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.221 uVs 15:10:34 Integrated Voltage Measurement... 15:10:43 Voltage Offset Correction: v_off_ini = 2328.722 uV, v_off_fin = 2311.597 uV 15:10:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.415 uVs 15:10:43 Integrated Voltage Measurement... 15:10:52 Voltage Offset Correction: v_off_ini = 2308.008 uV, v_off_fin = 2346.395 uV 15:10:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.633 uVs 15:10:52 Integrated Voltage Measurement... 15:11:01 Voltage Offset Correction: v_off_ini = 2337.715 uV, v_off_fin = 2346.488 uV 15:11:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.411 uVs 15:11:01 Integrated Voltage Measurement... 15:11:10 Voltage Offset Correction: v_off_ini = 2347.281 uV, v_off_fin = 2343.024 uV 15:11:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.365 uVs 15:11:15 I1Y Average and RMS of Measurements VT = -206.264 +- 9.514 uVs I1Y = -41.253 +- 1.903 uTm 15:11:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:11:20 Integrated Voltage Measurement... 15:11:29 Voltage Offset Correction: v_off_ini = 2318.184 uV, v_off_fin = 2310.069 uV 15:11:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -59.156 uVs 15:11:29 Integrated Voltage Measurement... 15:11:38 Voltage Offset Correction: v_off_ini = 2324.820 uV, v_off_fin = 2329.949 uV 15:11:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.887 uVs 15:11:38 Integrated Voltage Measurement... 15:11:47 Voltage Offset Correction: v_off_ini = 2342.891 uV, v_off_fin = 2327.981 uV 15:11:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.768 uVs 15:11:47 Integrated Voltage Measurement... 15:11:56 Voltage Offset Correction: v_off_ini = 2357.650 uV, v_off_fin = 2326.106 uV 15:11:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.816 uVs 15:11:56 Integrated Voltage Measurement... 15:12:05 Voltage Offset Correction: v_off_ini = 2318.876 uV, v_off_fin = 2314.658 uV 15:12:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.148 uVs 15:12:05 Integrated Voltage Measurement... 15:12:14 Voltage Offset Correction: v_off_ini = 2315.252 uV, v_off_fin = 2330.889 uV 15:12:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.562 uVs 15:12:16 I2X Average and RMS of Measurements VT = -71.556 +- 8.912 uVs I2X = 6.583 +- 0.820 uTm^2 15:12:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:12:21 Integrated Voltage Measurement... 15:12:30 Voltage Offset Correction: v_off_ini = 2370.349 uV, v_off_fin = 2335.346 uV 15:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -327.247 uVs 15:12:30 Integrated Voltage Measurement... 15:12:39 Voltage Offset Correction: v_off_ini = 2366.285 uV, v_off_fin = 2354.910 uV 15:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.068 uVs 15:12:39 Integrated Voltage Measurement... 15:12:48 Voltage Offset Correction: v_off_ini = 2393.920 uV, v_off_fin = 2379.789 uV 15:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.827 uVs 15:12:48 Integrated Voltage Measurement... 15:12:57 Voltage Offset Correction: v_off_ini = 2357.284 uV, v_off_fin = 2347.093 uV 15:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.560 uVs 15:12:57 Integrated Voltage Measurement... 15:13:06 Voltage Offset Correction: v_off_ini = 2351.100 uV, v_off_fin = 2330.229 uV 15:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.393 uVs 15:13:07 Integrated Voltage Measurement... 15:13:15 Voltage Offset Correction: v_off_ini = 2365.649 uV, v_off_fin = 2365.515 uV 15:13:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.195 uVs 15:13:18 I2Y Average and RMS of Measurements VT = -301.548 +- 11.638 uVs I2Y = -27.742 +- 1.071 uTm^2 15:13:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:13:26 Integrated Voltage Measurement... 15:13:35 Voltage Offset Correction: v_off_ini = 2387.955 uV, v_off_fin = 2353.449 uV 15:13:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.542 uVs 15:13:35 Integrated Voltage Measurement... 15:13:44 Voltage Offset Correction: v_off_ini = 2362.100 uV, v_off_fin = 2381.704 uV 15:13:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.395 uVs 15:13:44 Integrated Voltage Measurement... 15:13:53 Voltage Offset Correction: v_off_ini = 2376.059 uV, v_off_fin = 2388.082 uV 15:13:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.955 uVs 15:13:53 Integrated Voltage Measurement... 15:14:02 Voltage Offset Correction: v_off_ini = 2383.923 uV, v_off_fin = 2382.947 uV 15:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.692 uVs 15:14:02 Integrated Voltage Measurement... 15:14:11 Voltage Offset Correction: v_off_ini = 2359.143 uV, v_off_fin = 2367.576 uV 15:14:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.634 uVs 15:14:11 Integrated Voltage Measurement... 15:14:20 Voltage Offset Correction: v_off_ini = 2388.271 uV, v_off_fin = 2368.323 uV 15:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 50.331 uVs 15:14:24 I1X Average and RMS of Measurements VT = -79.425 +- 16.121 uVs I1X = 15.886 +- 3.224 uTm 15:14:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:14:31 Integrated Voltage Measurement... 15:14:40 Voltage Offset Correction: v_off_ini = 2362.429 uV, v_off_fin = 2373.921 uV 15:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.163 uVs 15:14:40 Integrated Voltage Measurement... 15:14:49 Voltage Offset Correction: v_off_ini = 2376.492 uV, v_off_fin = 2391.642 uV 15:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.424 uVs 15:14:49 Integrated Voltage Measurement... 15:14:58 Voltage Offset Correction: v_off_ini = 2354.315 uV, v_off_fin = 2376.918 uV 15:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.285 uVs 15:14:58 Integrated Voltage Measurement... 15:15:07 Voltage Offset Correction: v_off_ini = 2392.856 uV, v_off_fin = 2385.509 uV 15:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.027 uVs 15:15:07 Integrated Voltage Measurement... 15:15:16 Voltage Offset Correction: v_off_ini = 2370.596 uV, v_off_fin = 2359.728 uV 15:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.267 uVs 15:15:16 Integrated Voltage Measurement... 15:15:25 Voltage Offset Correction: v_off_ini = 2382.102 uV, v_off_fin = 2370.268 uV 15:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.988 uVs 15:15:29 I1Y Average and RMS of Measurements VT = -182.359 +- 5.670 uVs I1Y = -36.472 +- 1.134 uTm 15:15:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:15:35 Integrated Voltage Measurement... 15:15:44 Voltage Offset Correction: v_off_ini = 2347.193 uV, v_off_fin = 2336.473 uV 15:15:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.381 uVs 15:15:44 Integrated Voltage Measurement... 15:15:53 Voltage Offset Correction: v_off_ini = 2342.301 uV, v_off_fin = 2349.790 uV 15:15:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.958 uVs 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 2375.539 uV, v_off_fin = 2361.740 uV 15:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.719 uVs 15:16:02 Integrated Voltage Measurement... 15:16:11 Voltage Offset Correction: v_off_ini = 2365.625 uV, v_off_fin = 2341.604 uV 15:16:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 105.160 uVs 15:16:11 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 2363.922 uV, v_off_fin = 2373.614 uV 15:16:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.058 uVs 15:16:20 Integrated Voltage Measurement... 15:16:29 Voltage Offset Correction: v_off_ini = 2353.797 uV, v_off_fin = 2360.249 uV 15:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.851 uVs 15:16:31 I2X Average and RMS of Measurements VT = -84.688 +- 12.164 uVs I2X = 7.792 +- 1.119 uTm^2 15:16:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:16:36 Integrated Voltage Measurement... 15:16:45 Voltage Offset Correction: v_off_ini = 2373.625 uV, v_off_fin = 2360.837 uV 15:16:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -312.264 uVs 15:16:45 Integrated Voltage Measurement... 15:16:54 Voltage Offset Correction: v_off_ini = 2381.558 uV, v_off_fin = 2393.680 uV 15:16:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.733 uVs 15:16:54 Integrated Voltage Measurement... 15:17:03 Voltage Offset Correction: v_off_ini = 2384.532 uV, v_off_fin = 2373.265 uV 15:17:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.822 uVs 15:17:03 Integrated Voltage Measurement... 15:17:12 Voltage Offset Correction: v_off_ini = 2366.389 uV, v_off_fin = 2348.844 uV 15:17:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.369 uVs 15:17:12 Integrated Voltage Measurement... 15:17:21 Voltage Offset Correction: v_off_ini = 2383.525 uV, v_off_fin = 2372.060 uV 15:17:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.150 uVs 15:17:21 Integrated Voltage Measurement... 15:17:30 Voltage Offset Correction: v_off_ini = 2345.794 uV, v_off_fin = 2353.999 uV 15:17:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.831 uVs 15:17:33 I2Y Average and RMS of Measurements VT = -291.861 +- 9.585 uVs I2Y = -26.852 +- 0.882 uTm^2 15:17:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:41 Integrated Voltage Measurement... 15:17:50 Voltage Offset Correction: v_off_ini = 2353.115 uV, v_off_fin = 2331.723 uV 15:17:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.174 uVs 15:17:50 Integrated Voltage Measurement... 15:17:59 Voltage Offset Correction: v_off_ini = 2324.982 uV, v_off_fin = 2356.506 uV 15:17:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.362 uVs 15:17:59 Integrated Voltage Measurement... 15:18:08 Voltage Offset Correction: v_off_ini = 2387.475 uV, v_off_fin = 2366.963 uV 15:18:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.166 uVs 15:18:08 Integrated Voltage Measurement... 15:18:17 Voltage Offset Correction: v_off_ini = 2351.880 uV, v_off_fin = 2352.843 uV 15:18:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.453 uVs 15:18:17 Integrated Voltage Measurement... 15:18:26 Voltage Offset Correction: v_off_ini = 2367.805 uV, v_off_fin = 2360.995 uV 15:18:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.217 uVs 15:18:26 Integrated Voltage Measurement... 15:18:35 Voltage Offset Correction: v_off_ini = 2387.682 uV, v_off_fin = 2348.225 uV 15:18:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.314 uVs 15:18:39 I1X Average and RMS of Measurements VT = -74.614 +- 10.762 uVs I1X = 14.923 +- 2.152 uTm 15:18:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:46 Integrated Voltage Measurement... 15:18:55 Voltage Offset Correction: v_off_ini = 2371.268 uV, v_off_fin = 2358.087 uV 15:18:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.972 uVs 15:18:55 Integrated Voltage Measurement... 15:19:04 Voltage Offset Correction: v_off_ini = 2345.128 uV, v_off_fin = 2376.450 uV 15:19:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.917 uVs 15:19:04 Integrated Voltage Measurement... 15:19:13 Voltage Offset Correction: v_off_ini = 2374.437 uV, v_off_fin = 2378.992 uV 15:19:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.533 uVs 15:19:13 Integrated Voltage Measurement... 15:19:22 Voltage Offset Correction: v_off_ini = 2395.053 uV, v_off_fin = 2376.664 uV 15:19:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.735 uVs 15:19:22 Integrated Voltage Measurement... 15:19:31 Voltage Offset Correction: v_off_ini = 2373.763 uV, v_off_fin = 2386.042 uV 15:19:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.725 uVs 15:19:31 Integrated Voltage Measurement... 15:19:40 Voltage Offset Correction: v_off_ini = 2365.530 uV, v_off_fin = 2384.867 uV 15:19:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.810 uVs 15:19:44 I1Y Average and RMS of Measurements VT = -176.449 +- 2.721 uVs I1Y = -35.290 +- 0.544 uTm 15:19:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:49 Integrated Voltage Measurement... 15:19:58 Voltage Offset Correction: v_off_ini = 2379.932 uV, v_off_fin = 2367.059 uV 15:19:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.589 uVs 15:19:58 Integrated Voltage Measurement... 15:20:07 Voltage Offset Correction: v_off_ini = 2361.874 uV, v_off_fin = 2381.676 uV 15:20:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.372 uVs 15:20:07 Integrated Voltage Measurement... 15:20:16 Voltage Offset Correction: v_off_ini = 2373.361 uV, v_off_fin = 2330.973 uV 15:20:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -99.886 uVs 15:20:16 Integrated Voltage Measurement... 15:20:25 Voltage Offset Correction: v_off_ini = 2395.285 uV, v_off_fin = 2403.595 uV 15:20:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.348 uVs 15:20:26 Integrated Voltage Measurement... 15:20:34 Voltage Offset Correction: v_off_ini = 2371.023 uV, v_off_fin = 2369.084 uV 15:20:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.346 uVs 15:20:35 Integrated Voltage Measurement... 15:20:44 Voltage Offset Correction: v_off_ini = 2359.769 uV, v_off_fin = 2373.640 uV 15:20:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.718 uVs 15:20:46 I2X Average and RMS of Measurements VT = -71.043 +- 4.970 uVs I2X = 6.536 +- 0.457 uTm^2 15:20:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:20:51 Integrated Voltage Measurement... 15:21:00 Voltage Offset Correction: v_off_ini = 2370.421 uV, v_off_fin = 2367.661 uV 15:21:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.848 uVs 15:21:00 Integrated Voltage Measurement... 15:21:09 Voltage Offset Correction: v_off_ini = 2356.790 uV, v_off_fin = 2345.336 uV 15:21:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.591 uVs 15:21:09 Integrated Voltage Measurement... 15:21:18 Voltage Offset Correction: v_off_ini = 2364.444 uV, v_off_fin = 2370.115 uV 15:21:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.516 uVs 15:21:18 Integrated Voltage Measurement... 15:21:27 Voltage Offset Correction: v_off_ini = 2367.133 uV, v_off_fin = 2377.022 uV 15:21:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 289.046 uVs 15:21:27 Integrated Voltage Measurement... 15:21:36 Voltage Offset Correction: v_off_ini = 2368.624 uV, v_off_fin = 2364.497 uV 15:21:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.021 uVs 15:21:36 Integrated Voltage Measurement... 15:21:45 Voltage Offset Correction: v_off_ini = 2369.603 uV, v_off_fin = 2345.152 uV 15:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.538 uVs 15:21:48 I2Y Average and RMS of Measurements VT = -287.593 +- 5.189 uVs I2Y = -26.459 +- 0.478 uTm^2 15:21:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:21:56 Integrated Voltage Measurement... 15:22:05 Voltage Offset Correction: v_off_ini = 2354.238 uV, v_off_fin = 2345.891 uV 15:22:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.306 uVs 15:22:05 Integrated Voltage Measurement... 15:22:14 Voltage Offset Correction: v_off_ini = 2372.660 uV, v_off_fin = 2389.654 uV 15:22:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.443 uVs 15:22:14 Integrated Voltage Measurement... 15:22:23 Voltage Offset Correction: v_off_ini = 2364.002 uV, v_off_fin = 2349.836 uV 15:22:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.633 uVs 15:22:23 Integrated Voltage Measurement... 15:22:32 Voltage Offset Correction: v_off_ini = 2362.369 uV, v_off_fin = 2363.962 uV 15:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.358 uVs 15:22:32 Integrated Voltage Measurement... 15:22:41 Voltage Offset Correction: v_off_ini = 2339.959 uV, v_off_fin = 2348.305 uV 15:22:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.293 uVs 15:22:41 Integrated Voltage Measurement... 15:22:50 Voltage Offset Correction: v_off_ini = 2354.581 uV, v_off_fin = 2368.507 uV 15:22:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.241 uVs 15:22:54 I1X Average and RMS of Measurements VT = -67.546 +- 13.610 uVs I1X = 13.509 +- 2.722 uTm 15:22:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:23:01 Integrated Voltage Measurement... 15:23:10 Voltage Offset Correction: v_off_ini = 2368.956 uV, v_off_fin = 2356.532 uV 15:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -169.260 uVs 15:23:10 Integrated Voltage Measurement... 15:23:19 Voltage Offset Correction: v_off_ini = 2360.658 uV, v_off_fin = 2393.144 uV 15:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.168 uVs 15:23:19 Integrated Voltage Measurement... 15:23:28 Voltage Offset Correction: v_off_ini = 2370.736 uV, v_off_fin = 2361.478 uV 15:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.736 uVs 15:23:28 Integrated Voltage Measurement... 15:23:37 Voltage Offset Correction: v_off_ini = 2355.698 uV, v_off_fin = 2369.893 uV 15:23:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.440 uVs 15:23:37 Integrated Voltage Measurement... 15:23:46 Voltage Offset Correction: v_off_ini = 2342.303 uV, v_off_fin = 2335.235 uV 15:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.638 uVs 15:23:46 Integrated Voltage Measurement... 15:23:55 Voltage Offset Correction: v_off_ini = 2338.097 uV, v_off_fin = 2348.549 uV 15:23:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.278 uVs 15:23:59 I1Y Average and RMS of Measurements VT = -182.087 +- 14.241 uVs I1Y = -36.417 +- 2.848 uTm 15:24:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:24:04 Integrated Voltage Measurement... 15:24:13 Voltage Offset Correction: v_off_ini = 2355.681 uV, v_off_fin = 2351.165 uV 15:24:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.208 uVs 15:24:13 Integrated Voltage Measurement... 15:24:22 Voltage Offset Correction: v_off_ini = 2334.939 uV, v_off_fin = 2373.972 uV 15:24:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.326 uVs 15:24:22 Integrated Voltage Measurement... 15:24:31 Voltage Offset Correction: v_off_ini = 2363.473 uV, v_off_fin = 2347.845 uV 15:24:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.293 uVs 15:24:31 Integrated Voltage Measurement... 15:24:40 Voltage Offset Correction: v_off_ini = 2363.597 uV, v_off_fin = 2390.283 uV 15:24:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.029 uVs 15:24:40 Integrated Voltage Measurement... 15:24:49 Voltage Offset Correction: v_off_ini = 2368.163 uV, v_off_fin = 2392.618 uV 15:24:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.013 uVs 15:24:49 Integrated Voltage Measurement... 15:24:58 Voltage Offset Correction: v_off_ini = 2360.974 uV, v_off_fin = 2391.387 uV 15:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.226 uVs 15:25:00 I2X Average and RMS of Measurements VT = -88.016 +- 13.686 uVs I2X = 8.098 +- 1.259 uTm^2 15:25:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:25:05 Integrated Voltage Measurement... 15:25:14 Voltage Offset Correction: v_off_ini = 2355.839 uV, v_off_fin = 2372.280 uV 15:25:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.721 uVs 15:25:15 Integrated Voltage Measurement... 15:25:23 Voltage Offset Correction: v_off_ini = 2385.807 uV, v_off_fin = 2381.802 uV 15:25:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.580 uVs 15:25:24 Integrated Voltage Measurement... 15:25:32 Voltage Offset Correction: v_off_ini = 2374.626 uV, v_off_fin = 2358.635 uV 15:25:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.373 uVs 15:25:33 Integrated Voltage Measurement... 15:25:42 Voltage Offset Correction: v_off_ini = 2383.471 uV, v_off_fin = 2379.184 uV 15:25:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.986 uVs 15:25:42 Integrated Voltage Measurement... 15:25:51 Voltage Offset Correction: v_off_ini = 2378.159 uV, v_off_fin = 2390.384 uV 15:25:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.731 uVs 15:25:51 Integrated Voltage Measurement... 15:26:00 Voltage Offset Correction: v_off_ini = 2375.650 uV, v_off_fin = 2376.667 uV 15:26:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.251 uVs 15:26:02 I2Y Average and RMS of Measurements VT = -279.107 +- 8.899 uVs I2Y = -25.678 +- 0.819 uTm^2 15:26:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:26:10 Integrated Voltage Measurement... 15:26:19 Voltage Offset Correction: v_off_ini = 2386.383 uV, v_off_fin = 2374.358 uV 15:26:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.193 uVs 15:26:19 Integrated Voltage Measurement... 15:26:28 Voltage Offset Correction: v_off_ini = 2386.929 uV, v_off_fin = 2375.762 uV 15:26:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.054 uVs 15:26:28 Integrated Voltage Measurement... 15:26:37 Voltage Offset Correction: v_off_ini = 2372.866 uV, v_off_fin = 2364.245 uV 15:26:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.959 uVs 15:26:37 Integrated Voltage Measurement... 15:26:46 Voltage Offset Correction: v_off_ini = 2352.784 uV, v_off_fin = 2408.328 uV 15:26:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.185 uVs 15:26:46 Integrated Voltage Measurement... 15:26:55 Voltage Offset Correction: v_off_ini = 2385.244 uV, v_off_fin = 2381.330 uV 15:26:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.361 uVs 15:26:55 Integrated Voltage Measurement... 15:27:04 Voltage Offset Correction: v_off_ini = 2370.087 uV, v_off_fin = 2369.296 uV 15:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.037 uVs 15:27:08 I1X Average and RMS of Measurements VT = -75.965 +- 7.372 uVs I1X = 15.193 +- 1.474 uTm 15:27:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:27:15 Integrated Voltage Measurement... 15:27:24 Voltage Offset Correction: v_off_ini = 2384.097 uV, v_off_fin = 2358.397 uV 15:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.397 uVs 15:27:24 Integrated Voltage Measurement... 15:27:33 Voltage Offset Correction: v_off_ini = 2378.424 uV, v_off_fin = 2379.254 uV 15:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 163.659 uVs 15:27:33 Integrated Voltage Measurement... 15:27:42 Voltage Offset Correction: v_off_ini = 2415.686 uV, v_off_fin = 2377.676 uV 15:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.130 uVs 15:27:42 Integrated Voltage Measurement... 15:27:51 Voltage Offset Correction: v_off_ini = 2388.318 uV, v_off_fin = 2381.355 uV 15:27:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.265 uVs 15:27:51 Integrated Voltage Measurement... 15:28:00 Voltage Offset Correction: v_off_ini = 2379.462 uV, v_off_fin = 2390.635 uV 15:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.087 uVs 15:28:00 Integrated Voltage Measurement... 15:28:09 Voltage Offset Correction: v_off_ini = 2393.614 uV, v_off_fin = 2407.966 uV 15:28:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.037 uVs 15:28:13 I1Y Average and RMS of Measurements VT = -175.096 +- 3.017 uVs I1Y = -35.018 +- 0.605 uTm 15:28:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:28:18 Integrated Voltage Measurement... 15:28:27 Voltage Offset Correction: v_off_ini = 2368.592 uV, v_off_fin = 2370.774 uV 15:28:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.376 uVs 15:28:27 Integrated Voltage Measurement... 15:28:36 Voltage Offset Correction: v_off_ini = 2376.328 uV, v_off_fin = 2405.943 uV 15:28:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.371 uVs 15:28:36 Integrated Voltage Measurement... 15:28:45 Voltage Offset Correction: v_off_ini = 2382.367 uV, v_off_fin = 2380.490 uV 15:28:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.498 uVs 15:28:45 Integrated Voltage Measurement... 15:28:54 Voltage Offset Correction: v_off_ini = 2404.369 uV, v_off_fin = 2392.963 uV 15:28:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.292 uVs 15:28:54 Integrated Voltage Measurement... 15:29:03 Voltage Offset Correction: v_off_ini = 2410.070 uV, v_off_fin = 2373.227 uV 15:29:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.754 uVs 15:29:03 Integrated Voltage Measurement... 15:29:12 Voltage Offset Correction: v_off_ini = 2384.667 uV, v_off_fin = 2412.741 uV 15:29:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.886 uVs 15:29:15 I2X Average and RMS of Measurements VT = -91.363 +- 15.221 uVs I2X = 8.405 +- 1.400 uTm^2 15:29:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:29:20 Integrated Voltage Measurement... 15:29:29 Voltage Offset Correction: v_off_ini = 2390.430 uV, v_off_fin = 2395.612 uV 15:29:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.236 uVs 15:29:29 Integrated Voltage Measurement... 15:29:38 Voltage Offset Correction: v_off_ini = 2402.584 uV, v_off_fin = 2386.177 uV 15:29:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.749 uVs 15:29:38 Integrated Voltage Measurement... 15:29:47 Voltage Offset Correction: v_off_ini = 2372.513 uV, v_off_fin = 2352.847 uV 15:29:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.770 uVs 15:29:47 Integrated Voltage Measurement... 15:29:56 Voltage Offset Correction: v_off_ini = 2369.349 uV, v_off_fin = 2371.612 uV 15:29:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.338 uVs 15:29:56 Integrated Voltage Measurement... 15:30:05 Voltage Offset Correction: v_off_ini = 2363.669 uV, v_off_fin = 2402.428 uV 15:30:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.127 uVs 15:30:05 Integrated Voltage Measurement... 15:30:14 Voltage Offset Correction: v_off_ini = 2369.415 uV, v_off_fin = 2382.770 uV 15:30:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.991 uVs 15:30:16 I2Y Average and RMS of Measurements VT = -255.535 +- 6.738 uVs I2Y = -23.509 +- 0.620 uTm^2 15:30:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:30:37 Integrated Voltage Measurement... 15:30:46 Voltage Offset Correction: v_off_ini = 2416.168 uV, v_off_fin = 2423.504 uV 15:30:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.674 uVs 15:30:46 Integrated Voltage Measurement... 15:30:55 Voltage Offset Correction: v_off_ini = 2406.194 uV, v_off_fin = 2400.562 uV 15:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.438 uVs 15:30:55 Integrated Voltage Measurement... 15:31:04 Voltage Offset Correction: v_off_ini = 2387.788 uV, v_off_fin = 2380.423 uV 15:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.096 uVs 15:31:04 Integrated Voltage Measurement... 15:31:13 Voltage Offset Correction: v_off_ini = 2408.009 uV, v_off_fin = 2411.440 uV 15:31:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.052 uVs 15:31:14 Integrated Voltage Measurement... 15:31:22 Voltage Offset Correction: v_off_ini = 2391.156 uV, v_off_fin = 2381.976 uV 15:31:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.484 uVs 15:31:23 Integrated Voltage Measurement... 15:31:31 Voltage Offset Correction: v_off_ini = 2382.229 uV, v_off_fin = 2398.297 uV 15:31:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.540 uVs 15:31:36 I1X Average and RMS of Measurements VT = -91.214 +- 14.175 uVs I1X = 18.243 +- 2.835 uTm 15:31:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:31:42 Integrated Voltage Measurement... 15:31:51 Voltage Offset Correction: v_off_ini = 2395.789 uV, v_off_fin = 2377.033 uV 15:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.100 uVs 15:31:51 Integrated Voltage Measurement... 15:32:00 Voltage Offset Correction: v_off_ini = 2353.958 uV, v_off_fin = 2391.020 uV 15:32:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.645 uVs 15:32:00 Integrated Voltage Measurement... 15:32:09 Voltage Offset Correction: v_off_ini = 2379.197 uV, v_off_fin = 2384.269 uV 15:32:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.729 uVs 15:32:09 Integrated Voltage Measurement... 15:32:18 Voltage Offset Correction: v_off_ini = 2391.696 uV, v_off_fin = 2391.250 uV 15:32:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.423 uVs 15:32:18 Integrated Voltage Measurement... 15:32:27 Voltage Offset Correction: v_off_ini = 2401.181 uV, v_off_fin = 2379.895 uV 15:32:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.992 uVs 15:32:27 Integrated Voltage Measurement... 15:32:36 Voltage Offset Correction: v_off_ini = 2408.340 uV, v_off_fin = 2402.506 uV 15:32:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.647 uVs 15:32:40 I1Y Average and RMS of Measurements VT = -193.756 +- 6.801 uVs I1Y = -38.751 +- 1.360 uTm 15:32:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:32:48 Integrated Voltage Measurement... 15:32:57 Voltage Offset Correction: v_off_ini = 2393.002 uV, v_off_fin = 2389.977 uV 15:32:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.614 uVs 15:32:57 Integrated Voltage Measurement... 15:33:06 Voltage Offset Correction: v_off_ini = 2365.670 uV, v_off_fin = 2407.403 uV 15:33:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.184 uVs 15:33:06 Integrated Voltage Measurement... 15:33:15 Voltage Offset Correction: v_off_ini = 2405.861 uV, v_off_fin = 2382.754 uV 15:33:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -107.544 uVs 15:33:15 Integrated Voltage Measurement... 15:33:24 Voltage Offset Correction: v_off_ini = 2399.307 uV, v_off_fin = 2394.669 uV 15:33:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.155 uVs 15:33:24 Integrated Voltage Measurement... 15:33:33 Voltage Offset Correction: v_off_ini = 2402.026 uV, v_off_fin = 2384.322 uV 15:33:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -142.188 uVs 15:33:33 Integrated Voltage Measurement... 15:33:42 Voltage Offset Correction: v_off_ini = 2413.612 uV, v_off_fin = 2391.772 uV 15:33:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.702 uVs 15:33:45 I2X Average and RMS of Measurements VT = -120.565 +- 13.238 uVs I2X = 11.092 +- 1.218 uTm^2 15:33:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:33:52 Integrated Voltage Measurement... 15:34:01 Voltage Offset Correction: v_off_ini = 2384.284 uV, v_off_fin = 2400.146 uV 15:34:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.858 uVs 15:34:01 Integrated Voltage Measurement... 15:34:10 Voltage Offset Correction: v_off_ini = 2414.193 uV, v_off_fin = 2406.332 uV 15:34:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.821 uVs 15:34:10 Integrated Voltage Measurement... 15:34:19 Voltage Offset Correction: v_off_ini = 2372.563 uV, v_off_fin = 2393.053 uV 15:34:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.358 uVs 15:34:19 Integrated Voltage Measurement... 15:34:28 Voltage Offset Correction: v_off_ini = 2392.183 uV, v_off_fin = 2397.741 uV 15:34:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.247 uVs 15:34:28 Integrated Voltage Measurement... 15:34:37 Voltage Offset Correction: v_off_ini = 2386.358 uV, v_off_fin = 2367.584 uV 15:34:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.971 uVs 15:34:37 Integrated Voltage Measurement... 15:34:46 Voltage Offset Correction: v_off_ini = 2388.852 uV, v_off_fin = 2396.864 uV 15:34:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.425 uVs 15:34:49 I2Y Average and RMS of Measurements VT = -263.447 +- 3.303 uVs I2Y = -24.237 +- 0.304 uTm^2 15:34:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:34:58 Integrated Voltage Measurement... 15:35:07 Voltage Offset Correction: v_off_ini = 2400.939 uV, v_off_fin = 2385.994 uV 15:35:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.057 uVs 15:35:07 Integrated Voltage Measurement... 15:35:16 Voltage Offset Correction: v_off_ini = 2371.441 uV, v_off_fin = 2377.785 uV 15:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.529 uVs 15:35:16 Integrated Voltage Measurement... 15:35:25 Voltage Offset Correction: v_off_ini = 2384.162 uV, v_off_fin = 2367.070 uV 15:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.834 uVs 15:35:25 Integrated Voltage Measurement... 15:35:34 Voltage Offset Correction: v_off_ini = 2394.758 uV, v_off_fin = 2378.102 uV 15:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.057 uVs 15:35:34 Integrated Voltage Measurement... 15:35:43 Voltage Offset Correction: v_off_ini = 2389.161 uV, v_off_fin = 2364.216 uV 15:35:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.337 uVs 15:35:43 Integrated Voltage Measurement... 15:35:52 Voltage Offset Correction: v_off_ini = 2361.943 uV, v_off_fin = 2363.799 uV 15:35:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.120 uVs 15:35:56 I1X Average and RMS of Measurements VT = -93.656 +- 20.486 uVs I1X = 18.731 +- 4.098 uTm 15:35:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:36:03 Integrated Voltage Measurement... 15:36:12 Voltage Offset Correction: v_off_ini = 2388.821 uV, v_off_fin = 2368.294 uV 15:36:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.346 uVs 15:36:12 Integrated Voltage Measurement... 15:36:20 Voltage Offset Correction: v_off_ini = 2370.179 uV, v_off_fin = 2381.883 uV 15:36:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.339 uVs 15:36:21 Integrated Voltage Measurement... 15:36:29 Voltage Offset Correction: v_off_ini = 2343.469 uV, v_off_fin = 2359.538 uV 15:36:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.016 uVs 15:36:30 Integrated Voltage Measurement... 15:36:38 Voltage Offset Correction: v_off_ini = 2376.781 uV, v_off_fin = 2385.025 uV 15:36:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.572 uVs 15:36:39 Integrated Voltage Measurement... 15:36:47 Voltage Offset Correction: v_off_ini = 2371.641 uV, v_off_fin = 2359.554 uV 15:36:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.101 uVs 15:36:48 Integrated Voltage Measurement... 15:36:56 Voltage Offset Correction: v_off_ini = 2359.583 uV, v_off_fin = 2370.069 uV 15:36:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.154 uVs 15:37:01 I1Y Average and RMS of Measurements VT = -172.588 +- 10.134 uVs I1Y = -34.518 +- 2.027 uTm 15:37:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:37:08 Integrated Voltage Measurement... 15:37:17 Voltage Offset Correction: v_off_ini = 2355.981 uV, v_off_fin = 2348.616 uV 15:37:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.609 uVs 15:37:17 Integrated Voltage Measurement... 15:37:26 Voltage Offset Correction: v_off_ini = 2364.606 uV, v_off_fin = 2369.923 uV 15:37:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.700 uVs 15:37:26 Integrated Voltage Measurement... 15:37:35 Voltage Offset Correction: v_off_ini = 2341.087 uV, v_off_fin = 2341.265 uV 15:37:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -94.734 uVs 15:37:35 Integrated Voltage Measurement... 15:37:44 Voltage Offset Correction: v_off_ini = 2376.706 uV, v_off_fin = 2399.558 uV 15:37:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.066 uVs 15:37:44 Integrated Voltage Measurement... 15:37:53 Voltage Offset Correction: v_off_ini = 2392.408 uV, v_off_fin = 2384.308 uV 15:37:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.193 uVs 15:37:54 Integrated Voltage Measurement... 15:38:02 Voltage Offset Correction: v_off_ini = 2388.715 uV, v_off_fin = 2387.040 uV 15:38:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 103.937 uVs 15:38:05 I2X Average and RMS of Measurements VT = -106.540 +- 7.280 uVs I2X = 9.802 +- 0.669 uTm^2 15:38:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:38:13 Integrated Voltage Measurement... 15:38:22 Voltage Offset Correction: v_off_ini = 2377.480 uV, v_off_fin = 2357.058 uV 15:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.251 uVs 15:38:22 Integrated Voltage Measurement... 15:38:31 Voltage Offset Correction: v_off_ini = 2353.740 uV, v_off_fin = 2377.706 uV 15:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.316 uVs 15:38:31 Integrated Voltage Measurement... 15:38:40 Voltage Offset Correction: v_off_ini = 2382.750 uV, v_off_fin = 2395.646 uV 15:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.612 uVs 15:38:40 Integrated Voltage Measurement... 15:38:49 Voltage Offset Correction: v_off_ini = 2388.748 uV, v_off_fin = 2381.531 uV 15:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.687 uVs 15:38:49 Integrated Voltage Measurement... 15:38:58 Voltage Offset Correction: v_off_ini = 2368.653 uV, v_off_fin = 2374.084 uV 15:38:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.620 uVs 15:38:58 Integrated Voltage Measurement... 15:39:07 Voltage Offset Correction: v_off_ini = 2392.203 uV, v_off_fin = 2366.767 uV 15:39:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.256 uVs 15:39:09 I2Y Average and RMS of Measurements VT = -264.957 +- 1.131 uVs I2Y = -24.376 +- 0.104 uTm^2 15:39:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:18 Integrated Voltage Measurement... 15:39:27 Voltage Offset Correction: v_off_ini = 2342.024 uV, v_off_fin = 2370.464 uV 15:39:27 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -55.725 uVs 15:39:27 Integrated Voltage Measurement... 15:39:36 Voltage Offset Correction: v_off_ini = 2347.531 uV, v_off_fin = 2345.082 uV 15:39:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 67.967 uVs 15:39:36 Integrated Voltage Measurement... 15:39:45 Voltage Offset Correction: v_off_ini = 2336.614 uV, v_off_fin = 2356.293 uV 15:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.394 uVs 15:39:45 Integrated Voltage Measurement... 15:39:54 Voltage Offset Correction: v_off_ini = 2361.222 uV, v_off_fin = 2373.816 uV 15:39:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.842 uVs 15:39:54 Integrated Voltage Measurement... 15:40:03 Voltage Offset Correction: v_off_ini = 2381.150 uV, v_off_fin = 2374.651 uV 15:40:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.382 uVs 15:40:03 Integrated Voltage Measurement... 15:40:12 Voltage Offset Correction: v_off_ini = 2367.304 uV, v_off_fin = 2366.366 uV 15:40:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.034 uVs 15:40:16 I1X Average and RMS of Measurements VT = -64.891 +- 3.084 uVs I1X = 12.979 +- 0.616 uTm 15:40:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:23 Integrated Voltage Measurement... 15:40:32 Voltage Offset Correction: v_off_ini = 2358.545 uV, v_off_fin = 2371.686 uV 15:40:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.643 uVs 15:40:32 Integrated Voltage Measurement... 15:40:41 Voltage Offset Correction: v_off_ini = 2362.294 uV, v_off_fin = 2413.677 uV 15:40:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.240 uVs 15:40:41 Integrated Voltage Measurement... 15:40:50 Voltage Offset Correction: v_off_ini = 2408.053 uV, v_off_fin = 2378.431 uV 15:40:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.824 uVs 15:40:50 Integrated Voltage Measurement... 15:40:59 Voltage Offset Correction: v_off_ini = 2397.284 uV, v_off_fin = 2417.351 uV 15:40:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.466 uVs 15:40:59 Integrated Voltage Measurement... 15:41:08 Voltage Offset Correction: v_off_ini = 2386.799 uV, v_off_fin = 2383.888 uV 15:41:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.545 uVs 15:41:08 Integrated Voltage Measurement... 15:41:17 Voltage Offset Correction: v_off_ini = 2411.211 uV, v_off_fin = 2429.389 uV 15:41:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.940 uVs 15:41:21 I1Y Average and RMS of Measurements VT = -179.943 +- 8.217 uVs I1Y = -35.989 +- 1.643 uTm 15:41:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:29 Integrated Voltage Measurement... 15:41:38 Voltage Offset Correction: v_off_ini = 2398.013 uV, v_off_fin = 2432.049 uV 15:41:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.881 uVs 15:41:38 Integrated Voltage Measurement... 15:41:47 Voltage Offset Correction: v_off_ini = 2419.815 uV, v_off_fin = 2427.948 uV 15:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.397 uVs 15:41:47 Integrated Voltage Measurement... 15:41:56 Voltage Offset Correction: v_off_ini = 2415.392 uV, v_off_fin = 2422.271 uV 15:41:56 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -85.945 uVs 15:41:56 Integrated Voltage Measurement... 15:42:05 Voltage Offset Correction: v_off_ini = 2407.438 uV, v_off_fin = 2443.101 uV 15:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.033 uVs 15:42:05 Integrated Voltage Measurement... 15:42:14 Voltage Offset Correction: v_off_ini = 2431.116 uV, v_off_fin = 2426.685 uV 15:42:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.963 uVs 15:42:14 Integrated Voltage Measurement... 15:42:23 Voltage Offset Correction: v_off_ini = 2470.956 uV, v_off_fin = 2464.025 uV 15:42:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.322 uVs 15:42:25 I2X Average and RMS of Measurements VT = -85.257 +- 7.415 uVs I2X = 7.844 +- 0.682 uTm^2 15:42:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:33 Integrated Voltage Measurement... 15:42:42 Voltage Offset Correction: v_off_ini = 2430.594 uV, v_off_fin = 2461.235 uV 15:42:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.501 uVs 15:42:42 Integrated Voltage Measurement... 15:42:51 Voltage Offset Correction: v_off_ini = 2461.042 uV, v_off_fin = 2452.282 uV 15:42:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.943 uVs 15:42:51 Integrated Voltage Measurement... 15:43:00 Voltage Offset Correction: v_off_ini = 2420.728 uV, v_off_fin = 2437.116 uV 15:43:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.896 uVs 15:43:00 Integrated Voltage Measurement... 15:43:09 Voltage Offset Correction: v_off_ini = 2443.059 uV, v_off_fin = 2460.635 uV 15:43:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.295 uVs 15:43:09 Integrated Voltage Measurement... 15:43:18 Voltage Offset Correction: v_off_ini = 2442.897 uV, v_off_fin = 2448.549 uV 15:43:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.718 uVs 15:43:18 Integrated Voltage Measurement... 15:43:27 Voltage Offset Correction: v_off_ini = 2442.498 uV, v_off_fin = 2440.974 uV 15:43:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.721 uVs 15:43:30 I2Y Average and RMS of Measurements VT = -263.512 +- 1.002 uVs I2Y = -24.243 +- 0.092 uTm^2 15:43:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:43:39 Integrated Voltage Measurement... 15:43:48 Voltage Offset Correction: v_off_ini = 2457.803 uV, v_off_fin = 2446.179 uV 15:43:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.571 uVs 15:43:48 Integrated Voltage Measurement... 15:43:57 Voltage Offset Correction: v_off_ini = 2451.317 uV, v_off_fin = 2471.828 uV 15:43:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.878 uVs 15:43:57 Integrated Voltage Measurement... 15:44:06 Voltage Offset Correction: v_off_ini = 2469.831 uV, v_off_fin = 2454.609 uV 15:44:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.167 uVs 15:44:06 Integrated Voltage Measurement... 15:44:15 Voltage Offset Correction: v_off_ini = 2461.677 uV, v_off_fin = 2448.172 uV 15:44:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.609 uVs 15:44:15 Integrated Voltage Measurement... 15:44:24 Voltage Offset Correction: v_off_ini = 2460.443 uV, v_off_fin = 2425.078 uV 15:44:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.729 uVs 15:44:24 Integrated Voltage Measurement... 15:44:33 Voltage Offset Correction: v_off_ini = 2443.667 uV, v_off_fin = 2453.885 uV 15:44:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.204 uVs 15:44:37 I1X Average and RMS of Measurements VT = -75.860 +- 9.089 uVs I1X = 15.172 +- 1.818 uTm 15:44:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:44:44 Integrated Voltage Measurement... 15:44:53 Voltage Offset Correction: v_off_ini = 2446.674 uV, v_off_fin = 2451.970 uV 15:44:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.716 uVs 15:44:53 Integrated Voltage Measurement... 15:45:02 Voltage Offset Correction: v_off_ini = 2456.648 uV, v_off_fin = 2442.202 uV 15:45:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.192 uVs 15:45:02 Integrated Voltage Measurement... 15:45:11 Voltage Offset Correction: v_off_ini = 2434.125 uV, v_off_fin = 2430.488 uV 15:45:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.575 uVs 15:45:11 Integrated Voltage Measurement... 15:45:20 Voltage Offset Correction: v_off_ini = 2447.619 uV, v_off_fin = 2451.985 uV 15:45:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.375 uVs 15:45:20 Integrated Voltage Measurement... 15:45:29 Voltage Offset Correction: v_off_ini = 2442.301 uV, v_off_fin = 2430.311 uV 15:45:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.598 uVs 15:45:29 Integrated Voltage Measurement... 15:45:38 Voltage Offset Correction: v_off_ini = 2447.673 uV, v_off_fin = 2450.885 uV 15:45:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.609 uVs 15:45:42 I1Y Average and RMS of Measurements VT = -167.344 +- 5.120 uVs I1Y = -33.469 +- 1.024 uTm 15:45:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:45:49 Integrated Voltage Measurement... 15:45:58 Voltage Offset Correction: v_off_ini = 2430.816 uV, v_off_fin = 2407.029 uV 15:45:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.672 uVs 15:45:58 Integrated Voltage Measurement... 15:46:07 Voltage Offset Correction: v_off_ini = 2448.378 uV, v_off_fin = 2444.480 uV 15:46:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.751 uVs 15:46:08 Integrated Voltage Measurement... 15:46:16 Voltage Offset Correction: v_off_ini = 2409.760 uV, v_off_fin = 2416.741 uV 15:46:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.216 uVs 15:46:17 Integrated Voltage Measurement... 15:46:26 Voltage Offset Correction: v_off_ini = 2441.027 uV, v_off_fin = 2453.979 uV 15:46:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.318 uVs 15:46:26 Integrated Voltage Measurement... 15:46:35 Voltage Offset Correction: v_off_ini = 2435.062 uV, v_off_fin = 2428.187 uV 15:46:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.877 uVs 15:46:35 Integrated Voltage Measurement... 15:46:44 Voltage Offset Correction: v_off_ini = 2410.057 uV, v_off_fin = 2431.668 uV 15:46:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.946 uVs 15:46:46 I2X Average and RMS of Measurements VT = -79.297 +- 3.948 uVs I2X = 7.295 +- 0.363 uTm^2 15:46:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:46:54 Integrated Voltage Measurement... 15:47:03 Voltage Offset Correction: v_off_ini = 2434.537 uV, v_off_fin = 2419.743 uV 15:47:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.889 uVs 15:47:03 Integrated Voltage Measurement... 15:47:12 Voltage Offset Correction: v_off_ini = 2426.004 uV, v_off_fin = 2464.639 uV 15:47:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.678 uVs 15:47:12 Integrated Voltage Measurement... 15:47:21 Voltage Offset Correction: v_off_ini = 2458.697 uV, v_off_fin = 2444.810 uV 15:47:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.639 uVs 15:47:21 Integrated Voltage Measurement... 15:47:30 Voltage Offset Correction: v_off_ini = 2449.014 uV, v_off_fin = 2428.813 uV 15:47:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.556 uVs 15:47:30 Integrated Voltage Measurement... 15:47:39 Voltage Offset Correction: v_off_ini = 2429.233 uV, v_off_fin = 2480.323 uV 15:47:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.228 uVs 15:47:39 Integrated Voltage Measurement... 15:47:48 Voltage Offset Correction: v_off_ini = 2483.583 uV, v_off_fin = 2468.443 uV 15:47:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.154 uVs 15:47:50 I2Y Average and RMS of Measurements VT = -269.857 +- 13.267 uVs I2Y = -24.827 +- 1.221 uTm^2 15:47:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:47:59 Integrated Voltage Measurement... 15:48:08 Voltage Offset Correction: v_off_ini = 2458.819 uV, v_off_fin = 2418.711 uV 15:48:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.963 uVs 15:48:08 Integrated Voltage Measurement... 15:48:17 Voltage Offset Correction: v_off_ini = 2476.655 uV, v_off_fin = 2487.813 uV 15:48:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.815 uVs 15:48:17 Integrated Voltage Measurement... 15:48:26 Voltage Offset Correction: v_off_ini = 2460.851 uV, v_off_fin = 2463.249 uV 15:48:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.028 uVs 15:48:26 Integrated Voltage Measurement... 15:48:35 Voltage Offset Correction: v_off_ini = 2474.066 uV, v_off_fin = 2473.177 uV 15:48:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.424 uVs 15:48:35 Integrated Voltage Measurement... 15:48:44 Voltage Offset Correction: v_off_ini = 2492.580 uV, v_off_fin = 2468.146 uV 15:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.892 uVs 15:48:44 Integrated Voltage Measurement... 15:48:53 Voltage Offset Correction: v_off_ini = 2481.085 uV, v_off_fin = 2483.823 uV 15:48:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.233 uVs 15:48:57 I1X Average and RMS of Measurements VT = -48.726 +- 10.887 uVs I1X = 9.745 +- 2.177 uTm 15:49:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:49:04 Integrated Voltage Measurement... 15:49:13 Voltage Offset Correction: v_off_ini = 2461.295 uV, v_off_fin = 2449.227 uV 15:49:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.827 uVs 15:49:13 Integrated Voltage Measurement... 15:49:22 Voltage Offset Correction: v_off_ini = 2455.593 uV, v_off_fin = 2467.225 uV 15:49:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.948 uVs 15:49:22 Integrated Voltage Measurement... 15:49:31 Voltage Offset Correction: v_off_ini = 2468.217 uV, v_off_fin = 2446.830 uV 15:49:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.163 uVs 15:49:31 Integrated Voltage Measurement... 15:49:40 Voltage Offset Correction: v_off_ini = 2492.347 uV, v_off_fin = 2491.611 uV 15:49:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.904 uVs 15:49:40 Integrated Voltage Measurement... 15:49:49 Voltage Offset Correction: v_off_ini = 2461.458 uV, v_off_fin = 2486.476 uV 15:49:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.798 uVs 15:49:49 Integrated Voltage Measurement... 15:49:58 Voltage Offset Correction: v_off_ini = 2481.758 uV, v_off_fin = 2484.468 uV 15:49:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.659 uVs 15:50:02 I1Y Average and RMS of Measurements VT = -184.217 +- 12.552 uVs I1Y = -36.843 +- 2.510 uTm 15:50:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:50:10 Integrated Voltage Measurement... 15:50:19 Voltage Offset Correction: v_off_ini = 2473.647 uV, v_off_fin = 2457.591 uV 15:50:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -67.326 uVs 15:50:19 Integrated Voltage Measurement... 15:50:28 Voltage Offset Correction: v_off_ini = 2453.072 uV, v_off_fin = 2450.821 uV 15:50:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.565 uVs 15:50:28 Integrated Voltage Measurement... 15:50:37 Voltage Offset Correction: v_off_ini = 2483.474 uV, v_off_fin = 2475.827 uV 15:50:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.575 uVs 15:50:37 Integrated Voltage Measurement... 15:50:46 Voltage Offset Correction: v_off_ini = 2488.937 uV, v_off_fin = 2483.442 uV 15:50:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.497 uVs 15:50:46 Integrated Voltage Measurement... 15:50:55 Voltage Offset Correction: v_off_ini = 2481.823 uV, v_off_fin = 2485.654 uV 15:50:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.843 uVs 15:50:55 Integrated Voltage Measurement... 15:51:04 Voltage Offset Correction: v_off_ini = 2508.573 uV, v_off_fin = 2513.454 uV 15:51:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.763 uVs 15:51:07 I2X Average and RMS of Measurements VT = -50.928 +- 9.109 uVs I2X = 4.685 +- 0.838 uTm^2 15:51:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:51:14 Integrated Voltage Measurement... 15:51:23 Voltage Offset Correction: v_off_ini = 2451.895 uV, v_off_fin = 2460.018 uV 15:51:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.284 uVs 15:51:23 Integrated Voltage Measurement... 15:51:32 Voltage Offset Correction: v_off_ini = 2499.783 uV, v_off_fin = 2489.284 uV 15:51:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.684 uVs 15:51:32 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = 2489.692 uV, v_off_fin = 2491.851 uV 15:51:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.633 uVs 15:51:41 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = 2470.974 uV, v_off_fin = 2500.732 uV 15:51:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.864 uVs 15:51:50 Integrated Voltage Measurement... 15:51:59 Voltage Offset Correction: v_off_ini = 2515.168 uV, v_off_fin = 2501.563 uV 15:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.948 uVs 15:51:59 Integrated Voltage Measurement... 15:52:08 Voltage Offset Correction: v_off_ini = 2501.924 uV, v_off_fin = 2537.223 uV 15:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.397 uVs 15:52:11 I2Y Average and RMS of Measurements VT = -273.802 +- 8.528 uVs I2Y = -25.190 +- 0.785 uTm^2 15:52:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:52:23 Integrated Voltage Measurement... 15:52:32 Voltage Offset Correction: v_off_ini = 2506.505 uV, v_off_fin = 2486.956 uV 15:52:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -80.463 uVs 15:52:32 Integrated Voltage Measurement... 15:52:41 Voltage Offset Correction: v_off_ini = 2510.773 uV, v_off_fin = 2501.868 uV 15:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.972 uVs 15:52:41 Integrated Voltage Measurement... 15:52:50 Voltage Offset Correction: v_off_ini = 2509.417 uV, v_off_fin = 2506.065 uV 15:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.124 uVs 15:52:50 Integrated Voltage Measurement... 15:52:59 Voltage Offset Correction: v_off_ini = 2518.077 uV, v_off_fin = 2524.868 uV 15:52:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.771 uVs 15:52:59 Integrated Voltage Measurement... 15:53:08 Voltage Offset Correction: v_off_ini = 2520.377 uV, v_off_fin = 2512.001 uV 15:53:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.163 uVs 15:53:08 Integrated Voltage Measurement... 15:53:17 Voltage Offset Correction: v_off_ini = 2517.772 uV, v_off_fin = 2502.201 uV 15:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 90.317 uVs 15:53:21 I1X Average and RMS of Measurements VT = -74.968 +- 16.652 uVs I1X = 14.994 +- 3.331 uTm 15:53:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:53:28 Integrated Voltage Measurement... 15:53:37 Voltage Offset Correction: v_off_ini = 2530.904 uV, v_off_fin = 2516.834 uV 15:53:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.301 uVs 15:53:37 Integrated Voltage Measurement... 15:53:46 Voltage Offset Correction: v_off_ini = 2521.077 uV, v_off_fin = 2499.734 uV 15:53:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.393 uVs 15:53:46 Integrated Voltage Measurement... 15:53:55 Voltage Offset Correction: v_off_ini = 2504.609 uV, v_off_fin = 2506.055 uV 15:53:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.835 uVs 15:53:55 Integrated Voltage Measurement... 15:54:04 Voltage Offset Correction: v_off_ini = 2519.258 uV, v_off_fin = 2530.458 uV 15:54:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.145 uVs 15:54:04 Integrated Voltage Measurement... 15:54:13 Voltage Offset Correction: v_off_ini = 2559.297 uV, v_off_fin = 2510.726 uV 15:54:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.813 uVs 15:54:13 Integrated Voltage Measurement... 15:54:22 Voltage Offset Correction: v_off_ini = 2538.355 uV, v_off_fin = 2536.920 uV 15:54:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.132 uVs 15:54:26 I1Y Average and RMS of Measurements VT = -200.270 +- 10.503 uVs I1Y = -40.054 +- 2.101 uTm 15:54:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:54:31 Integrated Voltage Measurement... 15:54:40 Voltage Offset Correction: v_off_ini = 2544.258 uV, v_off_fin = 2512.678 uV 15:54:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.117 uVs 15:54:40 Integrated Voltage Measurement... 15:54:49 Voltage Offset Correction: v_off_ini = 2541.214 uV, v_off_fin = 2563.940 uV 15:54:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.981 uVs 15:54:49 Integrated Voltage Measurement... 15:54:58 Voltage Offset Correction: v_off_ini = 2518.510 uV, v_off_fin = 2529.787 uV 15:54:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.595 uVs 15:54:58 Integrated Voltage Measurement... 15:55:07 Voltage Offset Correction: v_off_ini = 2514.724 uV, v_off_fin = 2521.341 uV 15:55:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 117.033 uVs 15:55:07 Integrated Voltage Measurement... 15:55:16 Voltage Offset Correction: v_off_ini = 2512.777 uV, v_off_fin = 2525.128 uV 15:55:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.505 uVs 15:55:16 Integrated Voltage Measurement... 15:55:25 Voltage Offset Correction: v_off_ini = 2518.166 uV, v_off_fin = 2507.338 uV 15:55:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.878 uVs 15:55:28 I2X Average and RMS of Measurements VT = -79.351 +- 19.702 uVs I2X = 7.301 +- 1.813 uTm^2 15:55:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:55:33 Integrated Voltage Measurement... 15:55:42 Voltage Offset Correction: v_off_ini = 2547.961 uV, v_off_fin = 2576.121 uV 15:55:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.675 uVs 15:55:42 Integrated Voltage Measurement... 15:55:51 Voltage Offset Correction: v_off_ini = 2545.106 uV, v_off_fin = 2547.148 uV 15:55:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.637 uVs 15:55:51 Integrated Voltage Measurement... 15:56:00 Voltage Offset Correction: v_off_ini = 2538.667 uV, v_off_fin = 2518.726 uV 15:56:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.652 uVs 15:56:00 Integrated Voltage Measurement... 15:56:09 Voltage Offset Correction: v_off_ini = 2533.261 uV, v_off_fin = 2530.756 uV 15:56:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.007 uVs 15:56:09 Integrated Voltage Measurement... 15:56:18 Voltage Offset Correction: v_off_ini = 2500.708 uV, v_off_fin = 2522.326 uV 15:56:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.140 uVs 15:56:18 Integrated Voltage Measurement... 15:56:27 Voltage Offset Correction: v_off_ini = 2548.951 uV, v_off_fin = 2543.564 uV 15:56:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.788 uVs 15:56:29 I2Y Average and RMS of Measurements VT = -273.816 +- 6.012 uVs I2Y = -25.191 +- 0.553 uTm^2 15:56:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:56:38 Integrated Voltage Measurement... 15:56:47 Voltage Offset Correction: v_off_ini = 2545.333 uV, v_off_fin = 2537.286 uV 15:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.268 uVs 15:56:47 Integrated Voltage Measurement... 15:56:56 Voltage Offset Correction: v_off_ini = 2554.025 uV, v_off_fin = 2537.983 uV 15:56:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.200 uVs 15:56:56 Integrated Voltage Measurement... 15:57:05 Voltage Offset Correction: v_off_ini = 2520.773 uV, v_off_fin = 2552.861 uV 15:57:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.836 uVs 15:57:05 Integrated Voltage Measurement... 15:57:14 Voltage Offset Correction: v_off_ini = 2542.356 uV, v_off_fin = 2530.136 uV 15:57:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.570 uVs 15:57:14 Integrated Voltage Measurement... 15:57:23 Voltage Offset Correction: v_off_ini = 2531.747 uV, v_off_fin = 2512.920 uV 15:57:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.178 uVs 15:57:23 Integrated Voltage Measurement... 15:57:32 Voltage Offset Correction: v_off_ini = 2532.711 uV, v_off_fin = 2530.288 uV 15:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.822 uVs 15:57:36 I1X Average and RMS of Measurements VT = -66.979 +- 7.003 uVs I1X = 13.396 +- 1.400 uTm 15:57:38 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:57:43 Integrated Voltage Measurement... 15:57:52 Voltage Offset Correction: v_off_ini = 2527.837 uV, v_off_fin = 2523.201 uV 15:57:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.827 uVs 15:57:52 Integrated Voltage Measurement... 15:58:01 Voltage Offset Correction: v_off_ini = 2536.655 uV, v_off_fin = 2512.857 uV 15:58:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.686 uVs 15:58:01 Integrated Voltage Measurement... 15:58:10 Voltage Offset Correction: v_off_ini = 2539.568 uV, v_off_fin = 2526.014 uV 15:58:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.003 uVs 15:58:10 Integrated Voltage Measurement... 15:58:19 Voltage Offset Correction: v_off_ini = 2531.989 uV, v_off_fin = 2540.225 uV 15:58:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.908 uVs 15:58:19 Integrated Voltage Measurement... 15:58:28 Voltage Offset Correction: v_off_ini = 2524.151 uV, v_off_fin = 2516.194 uV 15:58:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.373 uVs 15:58:28 Integrated Voltage Measurement... 15:58:37 Voltage Offset Correction: v_off_ini = 2522.282 uV, v_off_fin = 2527.438 uV 15:58:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.753 uVs 15:58:41 I1Y Average and RMS of Measurements VT = -179.591 +- 14.039 uVs I1Y = -35.918 +- 2.808 uTm 15:58:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:58:46 Integrated Voltage Measurement... 15:58:55 Voltage Offset Correction: v_off_ini = 2481.465 uV, v_off_fin = 2473.760 uV 15:58:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.783 uVs 15:58:55 Integrated Voltage Measurement... 15:59:04 Voltage Offset Correction: v_off_ini = 2507.980 uV, v_off_fin = 2499.789 uV 15:59:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.079 uVs 15:59:04 Integrated Voltage Measurement... 15:59:13 Voltage Offset Correction: v_off_ini = 2490.689 uV, v_off_fin = 2481.065 uV 15:59:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.045 uVs 15:59:13 Integrated Voltage Measurement... 15:59:22 Voltage Offset Correction: v_off_ini = 2493.255 uV, v_off_fin = 2511.721 uV 15:59:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.290 uVs 15:59:22 Integrated Voltage Measurement... 15:59:31 Voltage Offset Correction: v_off_ini = 2496.330 uV, v_off_fin = 2494.331 uV 15:59:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.524 uVs 15:59:31 Integrated Voltage Measurement... 15:59:40 Voltage Offset Correction: v_off_ini = 2485.288 uV, v_off_fin = 2487.076 uV 15:59:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.382 uVs 15:59:42 I2X Average and RMS of Measurements VT = -85.184 +- 6.222 uVs I2X = 7.837 +- 0.572 uTm^2 15:59:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:59:48 Integrated Voltage Measurement... 15:59:57 Voltage Offset Correction: v_off_ini = 2493.485 uV, v_off_fin = 2478.305 uV 15:59:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.335 uVs 15:59:57 Integrated Voltage Measurement... 16:00:06 Voltage Offset Correction: v_off_ini = 2500.038 uV, v_off_fin = 2477.386 uV 16:00:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.229 uVs 16:00:06 Integrated Voltage Measurement... 16:00:15 Voltage Offset Correction: v_off_ini = 2490.871 uV, v_off_fin = 2507.067 uV 16:00:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.107 uVs 16:00:15 Integrated Voltage Measurement... 16:00:24 Voltage Offset Correction: v_off_ini = 2497.941 uV, v_off_fin = 2483.381 uV 16:00:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 267.832 uVs 16:00:24 Integrated Voltage Measurement... 16:00:33 Voltage Offset Correction: v_off_ini = 2525.780 uV, v_off_fin = 2515.880 uV 16:00:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.969 uVs 16:00:33 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = 2488.548 uV, v_off_fin = 2517.119 uV 16:00:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.410 uVs 16:00:44 I2Y Average and RMS of Measurements VT = -274.980 +- 22.881 uVs I2Y = -25.299 +- 2.105 uTm^2 16:00:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:53 Integrated Voltage Measurement... 16:01:01 Voltage Offset Correction: v_off_ini = 2494.685 uV, v_off_fin = 2502.562 uV 16:01:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.377 uVs 16:01:02 Integrated Voltage Measurement... 16:01:11 Voltage Offset Correction: v_off_ini = 2490.471 uV, v_off_fin = 2484.773 uV 16:01:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.904 uVs 16:01:11 Integrated Voltage Measurement... 16:01:20 Voltage Offset Correction: v_off_ini = 2499.895 uV, v_off_fin = 2497.276 uV 16:01:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.709 uVs 16:01:20 Integrated Voltage Measurement... 16:01:29 Voltage Offset Correction: v_off_ini = 2482.884 uV, v_off_fin = 2476.575 uV 16:01:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.383 uVs 16:01:29 Integrated Voltage Measurement... 16:01:38 Voltage Offset Correction: v_off_ini = 2484.558 uV, v_off_fin = 2501.527 uV 16:01:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.408 uVs 16:01:38 Integrated Voltage Measurement... 16:01:47 Voltage Offset Correction: v_off_ini = 2498.127 uV, v_off_fin = 2475.388 uV 16:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.966 uVs 16:01:51 I1X Average and RMS of Measurements VT = -83.291 +- 12.102 uVs I1X = 16.658 +- 2.420 uTm 16:01:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:58 Integrated Voltage Measurement... 16:02:06 Voltage Offset Correction: v_off_ini = 2478.807 uV, v_off_fin = 2455.226 uV 16:02:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.995 uVs 16:02:07 Integrated Voltage Measurement... 16:02:15 Voltage Offset Correction: v_off_ini = 2471.903 uV, v_off_fin = 2506.778 uV 16:02:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.994 uVs 16:02:16 Integrated Voltage Measurement... 16:02:24 Voltage Offset Correction: v_off_ini = 2472.259 uV, v_off_fin = 2495.843 uV 16:02:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.636 uVs 16:02:25 Integrated Voltage Measurement... 16:02:33 Voltage Offset Correction: v_off_ini = 2512.356 uV, v_off_fin = 2507.434 uV 16:02:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.400 uVs 16:02:34 Integrated Voltage Measurement... 16:02:42 Voltage Offset Correction: v_off_ini = 2517.897 uV, v_off_fin = 2477.589 uV 16:02:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.869 uVs 16:02:43 Integrated Voltage Measurement... 16:02:51 Voltage Offset Correction: v_off_ini = 2456.721 uV, v_off_fin = 2460.570 uV 16:02:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.004 uVs 16:02:56 I1Y Average and RMS of Measurements VT = -173.483 +- 6.075 uVs I1Y = -34.698 +- 1.215 uTm 16:02:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:01 Integrated Voltage Measurement... 16:03:10 Voltage Offset Correction: v_off_ini = 2466.361 uV, v_off_fin = 2451.462 uV 16:03:10 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -137.901 uVs 16:03:10 Integrated Voltage Measurement... 16:03:19 Voltage Offset Correction: v_off_ini = 2466.006 uV, v_off_fin = 2481.868 uV 16:03:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.739 uVs 16:03:19 Integrated Voltage Measurement... 16:03:28 Voltage Offset Correction: v_off_ini = 2453.251 uV, v_off_fin = 2430.073 uV 16:03:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.178 uVs 16:03:28 Integrated Voltage Measurement... 16:03:37 Voltage Offset Correction: v_off_ini = 2450.678 uV, v_off_fin = 2442.972 uV 16:03:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.719 uVs 16:03:37 Integrated Voltage Measurement... 16:03:46 Voltage Offset Correction: v_off_ini = 2434.209 uV, v_off_fin = 2450.852 uV 16:03:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.825 uVs 16:03:46 Integrated Voltage Measurement... 16:03:55 Voltage Offset Correction: v_off_ini = 2450.611 uV, v_off_fin = 2464.460 uV 16:03:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.661 uVs 16:03:57 I2X Average and RMS of Measurements VT = -96.670 +- 20.850 uVs I2X = 8.893 +- 1.918 uTm^2 16:04:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:02 Integrated Voltage Measurement... 16:04:11 Voltage Offset Correction: v_off_ini = 2421.190 uV, v_off_fin = 2436.237 uV 16:04:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.398 uVs 16:04:11 Integrated Voltage Measurement... 16:04:20 Voltage Offset Correction: v_off_ini = 2435.354 uV, v_off_fin = 2436.517 uV 16:04:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.194 uVs 16:04:21 Integrated Voltage Measurement... 16:04:29 Voltage Offset Correction: v_off_ini = 2431.630 uV, v_off_fin = 2435.769 uV 16:04:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.475 uVs 16:04:30 Integrated Voltage Measurement... 16:04:39 Voltage Offset Correction: v_off_ini = 2440.809 uV, v_off_fin = 2438.338 uV 16:04:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.295 uVs 16:04:39 Integrated Voltage Measurement... 16:04:48 Voltage Offset Correction: v_off_ini = 2456.546 uV, v_off_fin = 2466.031 uV 16:04:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.437 uVs 16:04:48 Integrated Voltage Measurement... 16:04:57 Voltage Offset Correction: v_off_ini = 2426.385 uV, v_off_fin = 2443.083 uV 16:04:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.702 uVs 16:04:59 I2Y Average and RMS of Measurements VT = -278.250 +- 14.657 uVs I2Y = -25.599 +- 1.348 uTm^2 16:05:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:05:07 Integrated Voltage Measurement... 16:05:16 Voltage Offset Correction: v_off_ini = 2478.430 uV, v_off_fin = 2471.771 uV 16:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.198 uVs 16:05:16 Integrated Voltage Measurement... 16:05:25 Voltage Offset Correction: v_off_ini = 2468.786 uV, v_off_fin = 2486.094 uV 16:05:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.071 uVs 16:05:25 Integrated Voltage Measurement... 16:05:34 Voltage Offset Correction: v_off_ini = 2506.327 uV, v_off_fin = 2491.319 uV 16:05:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.022 uVs 16:05:34 Integrated Voltage Measurement... 16:05:43 Voltage Offset Correction: v_off_ini = 2484.314 uV, v_off_fin = 2477.933 uV 16:05:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.518 uVs 16:05:43 Integrated Voltage Measurement... 16:05:52 Voltage Offset Correction: v_off_ini = 2472.796 uV, v_off_fin = 2466.383 uV 16:05:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.139 uVs 16:05:52 Integrated Voltage Measurement... 16:06:01 Voltage Offset Correction: v_off_ini = 2485.634 uV, v_off_fin = 2491.564 uV 16:06:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 63.693 uVs 16:06:06 I1X Average and RMS of Measurements VT = -86.607 +- 19.294 uVs I1X = 17.322 +- 3.859 uTm 16:06:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:06:12 Integrated Voltage Measurement... 16:06:21 Voltage Offset Correction: v_off_ini = 2476.576 uV, v_off_fin = 2467.734 uV 16:06:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.556 uVs 16:06:21 Integrated Voltage Measurement... 16:06:30 Voltage Offset Correction: v_off_ini = 2464.596 uV, v_off_fin = 2467.472 uV 16:06:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 131.894 uVs 16:06:30 Integrated Voltage Measurement... 16:06:39 Voltage Offset Correction: v_off_ini = 2466.269 uV, v_off_fin = 2463.642 uV 16:06:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.626 uVs 16:06:39 Integrated Voltage Measurement... 16:06:48 Voltage Offset Correction: v_off_ini = 2484.383 uV, v_off_fin = 2483.642 uV 16:06:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.705 uVs 16:06:48 Integrated Voltage Measurement... 16:06:57 Voltage Offset Correction: v_off_ini = 2458.387 uV, v_off_fin = 2441.492 uV 16:06:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.483 uVs 16:06:57 Integrated Voltage Measurement... 16:07:06 Voltage Offset Correction: v_off_ini = 2469.103 uV, v_off_fin = 2495.853 uV 16:07:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 165.192 uVs 16:07:10 I1Y Average and RMS of Measurements VT = -162.409 +- 10.393 uVs I1Y = -32.480 +- 2.078 uTm 16:07:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:07:16 Integrated Voltage Measurement... 16:07:25 Voltage Offset Correction: v_off_ini = 2492.031 uV, v_off_fin = 2470.711 uV 16:07:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.154 uVs 16:07:25 Integrated Voltage Measurement... 16:07:34 Voltage Offset Correction: v_off_ini = 2473.192 uV, v_off_fin = 2480.455 uV 16:07:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.866 uVs 16:07:34 Integrated Voltage Measurement... 16:07:43 Voltage Offset Correction: v_off_ini = 2495.816 uV, v_off_fin = 2476.708 uV 16:07:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.300 uVs 16:07:43 Integrated Voltage Measurement... 16:07:52 Voltage Offset Correction: v_off_ini = 2470.284 uV, v_off_fin = 2497.343 uV 16:07:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.507 uVs 16:07:52 Integrated Voltage Measurement... 16:08:01 Voltage Offset Correction: v_off_ini = 2469.707 uV, v_off_fin = 2461.127 uV 16:08:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.565 uVs 16:08:01 Integrated Voltage Measurement... 16:08:10 Voltage Offset Correction: v_off_ini = 2477.682 uV, v_off_fin = 2484.891 uV 16:08:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.090 uVs 16:08:12 I2X Average and RMS of Measurements VT = -87.580 +- 6.719 uVs I2X = 8.057 +- 0.618 uTm^2 16:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:08:17 Integrated Voltage Measurement... 16:08:26 Voltage Offset Correction: v_off_ini = 2458.594 uV, v_off_fin = 2469.576 uV 16:08:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -266.105 uVs 16:08:26 Integrated Voltage Measurement... 16:08:35 Voltage Offset Correction: v_off_ini = 2460.366 uV, v_off_fin = 2456.434 uV 16:08:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.910 uVs 16:08:35 Integrated Voltage Measurement... 16:08:44 Voltage Offset Correction: v_off_ini = 2469.531 uV, v_off_fin = 2478.995 uV 16:08:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.810 uVs 16:08:44 Integrated Voltage Measurement... 16:08:53 Voltage Offset Correction: v_off_ini = 2464.121 uV, v_off_fin = 2478.564 uV 16:08:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.741 uVs 16:08:53 Integrated Voltage Measurement... 16:09:02 Voltage Offset Correction: v_off_ini = 2484.423 uV, v_off_fin = 2467.424 uV 16:09:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.783 uVs 16:09:02 Integrated Voltage Measurement... 16:09:11 Voltage Offset Correction: v_off_ini = 2482.462 uV, v_off_fin = 2482.190 uV 16:09:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.700 uVs 16:09:14 I2Y Average and RMS of Measurements VT = -275.841 +- 4.255 uVs I2Y = -25.378 +- 0.391 uTm^2 16:09:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:09:22 Integrated Voltage Measurement... 16:09:31 Voltage Offset Correction: v_off_ini = 2479.961 uV, v_off_fin = 2477.869 uV 16:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.199 uVs 16:09:31 Integrated Voltage Measurement... 16:09:40 Voltage Offset Correction: v_off_ini = 2458.171 uV, v_off_fin = 2498.025 uV 16:09:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.203 uVs 16:09:40 Integrated Voltage Measurement... 16:09:49 Voltage Offset Correction: v_off_ini = 2485.165 uV, v_off_fin = 2476.405 uV 16:09:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.656 uVs 16:09:49 Integrated Voltage Measurement... 16:09:58 Voltage Offset Correction: v_off_ini = 2512.800 uV, v_off_fin = 2491.654 uV 16:09:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 81.130 uVs 16:09:58 Integrated Voltage Measurement... 16:10:07 Voltage Offset Correction: v_off_ini = 2475.238 uV, v_off_fin = 2468.218 uV 16:10:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.617 uVs 16:10:07 Integrated Voltage Measurement... 16:10:16 Voltage Offset Correction: v_off_ini = 2502.648 uV, v_off_fin = 2468.660 uV 16:10:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.723 uVs 16:10:20 I1X Average and RMS of Measurements VT = -77.588 +- 3.053 uVs I1X = 15.519 +- 0.610 uTm 16:10:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:10:27 Integrated Voltage Measurement... 16:10:36 Voltage Offset Correction: v_off_ini = 2459.302 uV, v_off_fin = 2440.973 uV 16:10:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.090 uVs 16:10:36 Integrated Voltage Measurement... 16:10:45 Voltage Offset Correction: v_off_ini = 2468.082 uV, v_off_fin = 2468.040 uV 16:10:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.446 uVs 16:10:45 Integrated Voltage Measurement... 16:10:54 Voltage Offset Correction: v_off_ini = 2472.800 uV, v_off_fin = 2462.382 uV 16:10:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -144.478 uVs 16:10:54 Integrated Voltage Measurement... 16:11:03 Voltage Offset Correction: v_off_ini = 2477.154 uV, v_off_fin = 2465.054 uV 16:11:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 161.247 uVs 16:11:03 Integrated Voltage Measurement... 16:11:12 Voltage Offset Correction: v_off_ini = 2478.935 uV, v_off_fin = 2483.160 uV 16:11:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.289 uVs 16:11:12 Integrated Voltage Measurement... 16:11:21 Voltage Offset Correction: v_off_ini = 2502.294 uV, v_off_fin = 2483.450 uV 16:11:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 155.687 uVs 16:11:25 I1Y Average and RMS of Measurements VT = -159.373 +- 5.480 uVs I1Y = -31.873 +- 1.097 uTm 16:11:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:11:30 Integrated Voltage Measurement... 16:11:39 Voltage Offset Correction: v_off_ini = 2483.624 uV, v_off_fin = 2469.013 uV 16:11:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.516 uVs 16:11:39 Integrated Voltage Measurement... 16:11:48 Voltage Offset Correction: v_off_ini = 2466.659 uV, v_off_fin = 2512.034 uV 16:11:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.967 uVs 16:11:48 Integrated Voltage Measurement... 16:11:57 Voltage Offset Correction: v_off_ini = 2491.506 uV, v_off_fin = 2500.643 uV 16:11:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.836 uVs 16:11:57 Integrated Voltage Measurement... 16:12:06 Voltage Offset Correction: v_off_ini = 2482.652 uV, v_off_fin = 2494.449 uV 16:12:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.124 uVs 16:12:06 Integrated Voltage Measurement... 16:12:15 Voltage Offset Correction: v_off_ini = 2478.044 uV, v_off_fin = 2490.956 uV 16:12:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.555 uVs 16:12:16 Integrated Voltage Measurement... 16:12:24 Voltage Offset Correction: v_off_ini = 2504.697 uV, v_off_fin = 2499.135 uV 16:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.754 uVs 16:12:27 I2X Average and RMS of Measurements VT = -77.792 +- 11.113 uVs I2X = 7.157 +- 1.022 uTm^2 16:12:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:12:32 Integrated Voltage Measurement... 16:12:41 Voltage Offset Correction: v_off_ini = 2471.830 uV, v_off_fin = 2473.424 uV 16:12:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.392 uVs 16:12:41 Integrated Voltage Measurement... 16:12:50 Voltage Offset Correction: v_off_ini = 2468.122 uV, v_off_fin = 2450.973 uV 16:12:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.927 uVs 16:12:50 Integrated Voltage Measurement... 16:12:59 Voltage Offset Correction: v_off_ini = 2461.749 uV, v_off_fin = 2465.926 uV 16:12:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.749 uVs 16:12:59 Integrated Voltage Measurement... 16:13:08 Voltage Offset Correction: v_off_ini = 2472.791 uV, v_off_fin = 2472.403 uV 16:13:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.603 uVs 16:13:08 Integrated Voltage Measurement... 16:13:17 Voltage Offset Correction: v_off_ini = 2471.250 uV, v_off_fin = 2474.073 uV 16:13:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.516 uVs 16:13:17 Integrated Voltage Measurement... 16:13:26 Voltage Offset Correction: v_off_ini = 2469.621 uV, v_off_fin = 2471.285 uV 16:13:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.433 uVs 16:13:29 I2Y Average and RMS of Measurements VT = -263.770 +- 6.661 uVs I2Y = -24.267 +- 0.613 uTm^2 16:13:59 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:14:03 Integrated Voltage Measurement... 16:14:12 Voltage Offset Correction: v_off_ini = 2500.257 uV, v_off_fin = 2479.662 uV 16:14:12 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -84.383 uVs 16:14:12 Integrated Voltage Measurement... 16:14:21 Voltage Offset Correction: v_off_ini = 2476.139 uV, v_off_fin = 2483.244 uV 16:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.771 uVs 16:14:21 Integrated Voltage Measurement... 16:14:30 Voltage Offset Correction: v_off_ini = 2487.867 uV, v_off_fin = 2494.761 uV 16:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.566 uVs 16:14:30 Integrated Voltage Measurement... 16:14:39 Voltage Offset Correction: v_off_ini = 2489.087 uV, v_off_fin = 2501.848 uV 16:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.717 uVs 16:14:39 Integrated Voltage Measurement... 16:14:48 Voltage Offset Correction: v_off_ini = 2518.740 uV, v_off_fin = 2513.835 uV 16:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.056 uVs 16:14:48 Integrated Voltage Measurement... 16:14:57 Voltage Offset Correction: v_off_ini = 2499.896 uV, v_off_fin = 2500.726 uV 16:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.153 uVs 16:15:02 I1X Average and RMS of Measurements VT = -85.441 +- 5.584 uVs I1X = 17.089 +- 1.117 uTm 16:15:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:15:08 Integrated Voltage Measurement... 16:15:17 Voltage Offset Correction: v_off_ini = 2509.009 uV, v_off_fin = 2493.471 uV 16:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.573 uVs 16:15:17 Integrated Voltage Measurement... 16:15:26 Voltage Offset Correction: v_off_ini = 2511.955 uV, v_off_fin = 2519.669 uV 16:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.091 uVs 16:15:26 Integrated Voltage Measurement... 16:15:35 Voltage Offset Correction: v_off_ini = 2498.701 uV, v_off_fin = 2508.211 uV 16:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.583 uVs 16:15:35 Integrated Voltage Measurement... 16:15:44 Voltage Offset Correction: v_off_ini = 2520.992 uV, v_off_fin = 2534.494 uV 16:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.370 uVs 16:15:44 Integrated Voltage Measurement... 16:15:53 Voltage Offset Correction: v_off_ini = 2502.849 uV, v_off_fin = 2495.172 uV 16:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.930 uVs 16:15:53 Integrated Voltage Measurement... 16:16:02 Voltage Offset Correction: v_off_ini = 2482.574 uV, v_off_fin = 2532.688 uV 16:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.199 uVs 16:16:07 I1Y Average and RMS of Measurements VT = -221.791 +- 7.463 uVs I1Y = -44.358 +- 1.493 uTm 16:16:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:16:14 Integrated Voltage Measurement... 16:16:23 Voltage Offset Correction: v_off_ini = 2465.533 uV, v_off_fin = 2480.873 uV 16:16:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -129.443 uVs 16:16:23 Integrated Voltage Measurement... 16:16:32 Voltage Offset Correction: v_off_ini = 2487.399 uV, v_off_fin = 2512.950 uV 16:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.553 uVs 16:16:32 Integrated Voltage Measurement... 16:16:41 Voltage Offset Correction: v_off_ini = 2511.065 uV, v_off_fin = 2476.661 uV 16:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.762 uVs 16:16:41 Integrated Voltage Measurement... 16:16:50 Voltage Offset Correction: v_off_ini = 2511.762 uV, v_off_fin = 2517.236 uV 16:16:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.708 uVs 16:16:50 Integrated Voltage Measurement... 16:16:59 Voltage Offset Correction: v_off_ini = 2501.887 uV, v_off_fin = 2490.818 uV 16:16:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.495 uVs 16:16:59 Integrated Voltage Measurement... 16:17:08 Voltage Offset Correction: v_off_ini = 2504.066 uV, v_off_fin = 2513.981 uV 16:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.864 uVs 16:17:11 I2X Average and RMS of Measurements VT = -91.638 +- 9.937 uVs I2X = 8.431 +- 0.914 uTm^2 16:17:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:17:19 Integrated Voltage Measurement... 16:17:27 Voltage Offset Correction: v_off_ini = 2496.920 uV, v_off_fin = 2491.564 uV 16:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.017 uVs 16:17:28 Integrated Voltage Measurement... 16:17:37 Voltage Offset Correction: v_off_ini = 2470.523 uV, v_off_fin = 2501.064 uV 16:17:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.431 uVs 16:17:37 Integrated Voltage Measurement... 16:17:46 Voltage Offset Correction: v_off_ini = 2505.071 uV, v_off_fin = 2490.161 uV 16:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.028 uVs 16:17:46 Integrated Voltage Measurement... 16:17:55 Voltage Offset Correction: v_off_ini = 2500.711 uV, v_off_fin = 2512.482 uV 16:17:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.776 uVs 16:17:55 Integrated Voltage Measurement... 16:18:04 Voltage Offset Correction: v_off_ini = 2480.477 uV, v_off_fin = 2501.384 uV 16:18:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.913 uVs 16:18:04 Integrated Voltage Measurement... 16:18:13 Voltage Offset Correction: v_off_ini = 2528.433 uV, v_off_fin = 2514.796 uV 16:18:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.781 uVs 16:18:15 I2Y Average and RMS of Measurements VT = -267.991 +- 9.499 uVs I2Y = -24.655 +- 0.874 uTm^2 16:18:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:18:24 Integrated Voltage Measurement... 16:18:33 Voltage Offset Correction: v_off_ini = 2511.497 uV, v_off_fin = 2506.695 uV 16:18:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.271 uVs 16:18:33 Integrated Voltage Measurement... 16:18:42 Voltage Offset Correction: v_off_ini = 2508.619 uV, v_off_fin = 2478.651 uV 16:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.165 uVs 16:18:42 Integrated Voltage Measurement... 16:18:51 Voltage Offset Correction: v_off_ini = 2501.171 uV, v_off_fin = 2494.784 uV 16:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.101 uVs 16:18:51 Integrated Voltage Measurement... 16:19:00 Voltage Offset Correction: v_off_ini = 2511.332 uV, v_off_fin = 2504.570 uV 16:19:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.822 uVs 16:19:00 Integrated Voltage Measurement... 16:19:09 Voltage Offset Correction: v_off_ini = 2504.038 uV, v_off_fin = 2510.159 uV 16:19:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.649 uVs 16:19:09 Integrated Voltage Measurement... 16:19:18 Voltage Offset Correction: v_off_ini = 2535.653 uV, v_off_fin = 2557.682 uV 16:19:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.819 uVs 16:19:22 I1X Average and RMS of Measurements VT = -87.638 +- 9.296 uVs I1X = 17.528 +- 1.858 uTm 16:19:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:19:29 Integrated Voltage Measurement... 16:19:38 Voltage Offset Correction: v_off_ini = 2540.387 uV, v_off_fin = 2539.809 uV 16:19:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.543 uVs 16:19:38 Integrated Voltage Measurement... 16:19:47 Voltage Offset Correction: v_off_ini = 2544.900 uV, v_off_fin = 2550.711 uV 16:19:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.674 uVs 16:19:47 Integrated Voltage Measurement... 16:19:56 Voltage Offset Correction: v_off_ini = 2524.792 uV, v_off_fin = 2551.690 uV 16:19:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.437 uVs 16:19:56 Integrated Voltage Measurement... 16:20:05 Voltage Offset Correction: v_off_ini = 2536.104 uV, v_off_fin = 2537.428 uV 16:20:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.491 uVs 16:20:05 Integrated Voltage Measurement... 16:20:14 Voltage Offset Correction: v_off_ini = 2504.204 uV, v_off_fin = 2500.627 uV 16:20:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.584 uVs 16:20:14 Integrated Voltage Measurement... 16:20:23 Voltage Offset Correction: v_off_ini = 2528.026 uV, v_off_fin = 2533.410 uV 16:20:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.423 uVs 16:20:27 I1Y Average and RMS of Measurements VT = -201.858 +- 5.969 uVs I1Y = -40.372 +- 1.194 uTm 16:20:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:20:35 Integrated Voltage Measurement... 16:20:44 Voltage Offset Correction: v_off_ini = 2506.880 uV, v_off_fin = 2525.689 uV 16:20:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.757 uVs 16:20:44 Integrated Voltage Measurement... 16:20:53 Voltage Offset Correction: v_off_ini = 2527.910 uV, v_off_fin = 2563.287 uV 16:20:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.237 uVs 16:20:53 Integrated Voltage Measurement... 16:21:02 Voltage Offset Correction: v_off_ini = 2537.615 uV, v_off_fin = 2547.447 uV 16:21:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.196 uVs 16:21:02 Integrated Voltage Measurement... 16:21:11 Voltage Offset Correction: v_off_ini = 2569.086 uV, v_off_fin = 2586.614 uV 16:21:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.171 uVs 16:21:11 Integrated Voltage Measurement... 16:21:20 Voltage Offset Correction: v_off_ini = 2543.791 uV, v_off_fin = 2543.685 uV 16:21:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.197 uVs 16:21:20 Integrated Voltage Measurement... 16:21:29 Voltage Offset Correction: v_off_ini = 2561.948 uV, v_off_fin = 2573.723 uV 16:21:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.710 uVs 16:21:31 I2X Average and RMS of Measurements VT = -88.545 +- 10.806 uVs I2X = 8.146 +- 0.994 uTm^2 16:21:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:21:39 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 2549.376 uV, v_off_fin = 2568.107 uV 16:21:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.005 uVs 16:21:48 Integrated Voltage Measurement... 16:21:57 Voltage Offset Correction: v_off_ini = 2553.855 uV, v_off_fin = 2561.619 uV 16:21:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.240 uVs 16:21:57 Integrated Voltage Measurement... 16:22:06 Voltage Offset Correction: v_off_ini = 2555.426 uV, v_off_fin = 2556.909 uV 16:22:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.236 uVs 16:22:06 Integrated Voltage Measurement... 16:22:15 Voltage Offset Correction: v_off_ini = 2537.903 uV, v_off_fin = 2555.697 uV 16:22:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 256.504 uVs 16:22:15 Integrated Voltage Measurement... 16:22:24 Voltage Offset Correction: v_off_ini = 2546.063 uV, v_off_fin = 2553.574 uV 16:22:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.893 uVs 16:22:24 Integrated Voltage Measurement... 16:22:33 Voltage Offset Correction: v_off_ini = 2566.976 uV, v_off_fin = 2565.865 uV 16:22:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.766 uVs 16:22:36 I2Y Average and RMS of Measurements VT = -263.441 +- 3.892 uVs I2Y = -24.237 +- 0.358 uTm^2 16:22:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:45 Integrated Voltage Measurement... 16:22:54 Voltage Offset Correction: v_off_ini = 2554.048 uV, v_off_fin = 2554.828 uV 16:22:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.185 uVs 16:22:54 Integrated Voltage Measurement... 16:23:03 Voltage Offset Correction: v_off_ini = 2573.788 uV, v_off_fin = 2552.162 uV 16:23:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.933 uVs 16:23:03 Integrated Voltage Measurement... 16:23:12 Voltage Offset Correction: v_off_ini = 2555.546 uV, v_off_fin = 2552.511 uV 16:23:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.321 uVs 16:23:12 Integrated Voltage Measurement... 16:23:21 Voltage Offset Correction: v_off_ini = 2549.383 uV, v_off_fin = 2582.338 uV 16:23:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.452 uVs 16:23:21 Integrated Voltage Measurement... 16:23:30 Voltage Offset Correction: v_off_ini = 2565.799 uV, v_off_fin = 2570.842 uV 16:23:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.392 uVs 16:23:30 Integrated Voltage Measurement... 16:23:39 Voltage Offset Correction: v_off_ini = 2545.800 uV, v_off_fin = 2577.631 uV 16:23:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.062 uVs 16:23:43 I1X Average and RMS of Measurements VT = -72.891 +- 15.892 uVs I1X = 14.579 +- 3.179 uTm 16:23:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:50 Integrated Voltage Measurement... 16:23:59 Voltage Offset Correction: v_off_ini = 2558.302 uV, v_off_fin = 2575.588 uV 16:23:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.148 uVs 16:23:59 Integrated Voltage Measurement... 16:24:08 Voltage Offset Correction: v_off_ini = 2591.347 uV, v_off_fin = 2599.794 uV 16:24:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.736 uVs 16:24:08 Integrated Voltage Measurement... 16:24:17 Voltage Offset Correction: v_off_ini = 2580.360 uV, v_off_fin = 2559.267 uV 16:24:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.065 uVs 16:24:17 Integrated Voltage Measurement... 16:24:26 Voltage Offset Correction: v_off_ini = 2563.078 uV, v_off_fin = 2597.340 uV 16:24:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.590 uVs 16:24:26 Integrated Voltage Measurement... 16:24:35 Voltage Offset Correction: v_off_ini = 2601.684 uV, v_off_fin = 2583.917 uV 16:24:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.586 uVs 16:24:35 Integrated Voltage Measurement... 16:24:44 Voltage Offset Correction: v_off_ini = 2622.605 uV, v_off_fin = 2617.302 uV 16:24:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.289 uVs 16:24:48 I1Y Average and RMS of Measurements VT = -217.903 +- 6.741 uVs I1Y = -43.581 +- 1.348 uTm 16:24:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:55 Integrated Voltage Measurement... 16:25:04 Voltage Offset Correction: v_off_ini = 2601.217 uV, v_off_fin = 2584.072 uV 16:25:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.346 uVs 16:25:04 Integrated Voltage Measurement... 16:25:13 Voltage Offset Correction: v_off_ini = 2609.153 uV, v_off_fin = 2613.616 uV 16:25:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.595 uVs 16:25:14 Integrated Voltage Measurement... 16:25:22 Voltage Offset Correction: v_off_ini = 2595.702 uV, v_off_fin = 2607.547 uV 16:25:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.871 uVs 16:25:23 Integrated Voltage Measurement... 16:25:32 Voltage Offset Correction: v_off_ini = 2612.273 uV, v_off_fin = 2635.688 uV 16:25:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.372 uVs 16:25:32 Integrated Voltage Measurement... 16:25:41 Voltage Offset Correction: v_off_ini = 2622.637 uV, v_off_fin = 2608.967 uV 16:25:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.979 uVs 16:25:41 Integrated Voltage Measurement... 16:25:50 Voltage Offset Correction: v_off_ini = 2606.178 uV, v_off_fin = 2620.210 uV 16:25:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.428 uVs 16:25:52 I2X Average and RMS of Measurements VT = -109.432 +- 14.715 uVs I2X = 10.068 +- 1.354 uTm^2 16:25:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:00 Integrated Voltage Measurement... 16:26:09 Voltage Offset Correction: v_off_ini = 2582.594 uV, v_off_fin = 2610.595 uV 16:26:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.283 uVs 16:26:09 Integrated Voltage Measurement... 16:26:18 Voltage Offset Correction: v_off_ini = 2587.835 uV, v_off_fin = 2586.481 uV 16:26:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.903 uVs 16:26:18 Integrated Voltage Measurement... 16:26:27 Voltage Offset Correction: v_off_ini = 2588.817 uV, v_off_fin = 2605.022 uV 16:26:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.744 uVs 16:26:27 Integrated Voltage Measurement... 16:26:36 Voltage Offset Correction: v_off_ini = 2605.780 uV, v_off_fin = 2597.920 uV 16:26:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.942 uVs 16:26:36 Integrated Voltage Measurement... 16:26:45 Voltage Offset Correction: v_off_ini = 2600.287 uV, v_off_fin = 2581.206 uV 16:26:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.397 uVs 16:26:45 Integrated Voltage Measurement... 16:26:54 Voltage Offset Correction: v_off_ini = 2599.549 uV, v_off_fin = 2614.030 uV 16:26:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.701 uVs 16:26:56 I2Y Average and RMS of Measurements VT = -266.995 +- 13.771 uVs I2Y = -24.564 +- 1.267 uTm^2 16:27:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:27:05 Integrated Voltage Measurement... 16:27:14 Voltage Offset Correction: v_off_ini = 2607.072 uV, v_off_fin = 2586.718 uV 16:27:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.999 uVs 16:27:14 Integrated Voltage Measurement... 16:27:23 Voltage Offset Correction: v_off_ini = 2613.715 uV, v_off_fin = 2622.750 uV 16:27:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.566 uVs 16:27:23 Integrated Voltage Measurement... 16:27:32 Voltage Offset Correction: v_off_ini = 2636.075 uV, v_off_fin = 2620.373 uV 16:27:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.821 uVs 16:27:32 Integrated Voltage Measurement... 16:27:41 Voltage Offset Correction: v_off_ini = 2617.961 uV, v_off_fin = 2600.209 uV 16:27:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.705 uVs 16:27:41 Integrated Voltage Measurement... 16:27:50 Voltage Offset Correction: v_off_ini = 2608.895 uV, v_off_fin = 2592.855 uV 16:27:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.519 uVs 16:27:50 Integrated Voltage Measurement... 16:27:59 Voltage Offset Correction: v_off_ini = 2617.611 uV, v_off_fin = 2614.512 uV 16:27:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.345 uVs 16:28:04 I1X Average and RMS of Measurements VT = -78.159 +- 15.485 uVs I1X = 15.632 +- 3.097 uTm 16:28:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:28:10 Integrated Voltage Measurement... 16:28:19 Voltage Offset Correction: v_off_ini = 2599.087 uV, v_off_fin = 2597.553 uV 16:28:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.786 uVs 16:28:19 Integrated Voltage Measurement... 16:28:28 Voltage Offset Correction: v_off_ini = 2595.015 uV, v_off_fin = 2599.470 uV 16:28:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.924 uVs 16:28:28 Integrated Voltage Measurement... 16:28:37 Voltage Offset Correction: v_off_ini = 2587.258 uV, v_off_fin = 2588.841 uV 16:28:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.411 uVs 16:28:37 Integrated Voltage Measurement... 16:28:46 Voltage Offset Correction: v_off_ini = 2609.605 uV, v_off_fin = 2607.136 uV 16:28:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.804 uVs 16:28:46 Integrated Voltage Measurement... 16:28:55 Voltage Offset Correction: v_off_ini = 2599.002 uV, v_off_fin = 2585.990 uV 16:28:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.012 uVs 16:28:55 Integrated Voltage Measurement... 16:29:04 Voltage Offset Correction: v_off_ini = 2585.529 uV, v_off_fin = 2605.675 uV 16:29:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.955 uVs 16:29:08 I1Y Average and RMS of Measurements VT = -214.149 +- 7.971 uVs I1Y = -42.830 +- 1.594 uTm 16:29:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:29:16 Integrated Voltage Measurement... 16:29:25 Voltage Offset Correction: v_off_ini = 2604.917 uV, v_off_fin = 2587.174 uV 16:29:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -79.469 uVs 16:29:25 Integrated Voltage Measurement... 16:29:34 Voltage Offset Correction: v_off_ini = 2627.358 uV, v_off_fin = 2637.808 uV 16:29:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.865 uVs 16:29:34 Integrated Voltage Measurement... 16:29:43 Voltage Offset Correction: v_off_ini = 2589.036 uV, v_off_fin = 2581.688 uV 16:29:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.165 uVs 16:29:43 Integrated Voltage Measurement... 16:29:52 Voltage Offset Correction: v_off_ini = 2568.854 uV, v_off_fin = 2585.208 uV 16:29:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.262 uVs 16:29:52 Integrated Voltage Measurement... 16:30:01 Voltage Offset Correction: v_off_ini = 2552.438 uV, v_off_fin = 2537.776 uV 16:30:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.281 uVs 16:30:01 Integrated Voltage Measurement... 16:30:10 Voltage Offset Correction: v_off_ini = 2554.705 uV, v_off_fin = 2580.028 uV 16:30:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.206 uVs 16:30:13 I2X Average and RMS of Measurements VT = -66.042 +- 19.910 uVs I2X = 6.076 +- 1.832 uTm^2 16:30:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:30:20 Integrated Voltage Measurement... 16:30:29 Voltage Offset Correction: v_off_ini = 2571.345 uV, v_off_fin = 2565.529 uV 16:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.447 uVs 16:30:29 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = 2573.879 uV, v_off_fin = 2570.920 uV 16:30:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.282 uVs 16:30:38 Integrated Voltage Measurement... 16:30:47 Voltage Offset Correction: v_off_ini = 2574.329 uV, v_off_fin = 2547.726 uV 16:30:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.127 uVs 16:30:48 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = 2557.652 uV, v_off_fin = 2550.318 uV 16:30:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.731 uVs 16:30:57 Integrated Voltage Measurement... 16:31:06 Voltage Offset Correction: v_off_ini = 2564.791 uV, v_off_fin = 2545.277 uV 16:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.974 uVs 16:31:06 Integrated Voltage Measurement... 16:31:15 Voltage Offset Correction: v_off_ini = 2537.466 uV, v_off_fin = 2540.450 uV 16:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.394 uVs 16:31:17 I2Y Average and RMS of Measurements VT = -251.826 +- 7.484 uVs I2Y = -23.168 +- 0.689 uTm^2 16:31:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:31:26 Integrated Voltage Measurement... 16:31:35 Voltage Offset Correction: v_off_ini = 2581.266 uV, v_off_fin = 2552.929 uV 16:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.451 uVs 16:31:35 Integrated Voltage Measurement... 16:31:44 Voltage Offset Correction: v_off_ini = 2566.247 uV, v_off_fin = 2560.001 uV 16:31:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.711 uVs 16:31:44 Integrated Voltage Measurement... 16:31:53 Voltage Offset Correction: v_off_ini = 2562.458 uV, v_off_fin = 2567.797 uV 16:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.190 uVs 16:31:53 Integrated Voltage Measurement... 16:32:02 Voltage Offset Correction: v_off_ini = 2583.318 uV, v_off_fin = 2568.186 uV 16:32:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.648 uVs 16:32:02 Integrated Voltage Measurement... 16:32:11 Voltage Offset Correction: v_off_ini = 2562.611 uV, v_off_fin = 2553.030 uV 16:32:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.489 uVs 16:32:11 Integrated Voltage Measurement... 16:32:20 Voltage Offset Correction: v_off_ini = 2577.086 uV, v_off_fin = 2594.354 uV 16:32:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.349 uVs 16:32:24 I1X Average and RMS of Measurements VT = -74.306 +- 20.255 uVs I1X = 14.862 +- 4.051 uTm 16:32:27 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 2577.310 uV, v_off_fin = 2582.789 uV 16:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.843 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 2566.766 uV, v_off_fin = 2596.992 uV 16:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.409 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 2585.909 uV, v_off_fin = 2568.802 uV 16:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.101 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 2569.816 uV, v_off_fin = 2602.725 uV 16:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.866 uVs 16:33:07 Integrated Voltage Measurement... 16:33:16 Voltage Offset Correction: v_off_ini = 2596.263 uV, v_off_fin = 2601.082 uV 16:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.144 uVs 16:33:16 Integrated Voltage Measurement... 16:33:25 Voltage Offset Correction: v_off_ini = 2570.413 uV, v_off_fin = 2582.006 uV 16:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.894 uVs 16:33:29 I1Y Average and RMS of Measurements VT = -221.210 +- 4.770 uVs I1Y = -44.242 +- 0.954 uTm 16:33:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:33:37 Integrated Voltage Measurement... 16:33:46 Voltage Offset Correction: v_off_ini = 2596.153 uV, v_off_fin = 2593.959 uV 16:33:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.858 uVs 16:33:46 Integrated Voltage Measurement... 16:33:55 Voltage Offset Correction: v_off_ini = 2614.869 uV, v_off_fin = 2597.297 uV 16:33:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.394 uVs 16:33:55 Integrated Voltage Measurement... 16:34:04 Voltage Offset Correction: v_off_ini = 2604.848 uV, v_off_fin = 2613.043 uV 16:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.817 uVs 16:34:04 Integrated Voltage Measurement... 16:34:13 Voltage Offset Correction: v_off_ini = 2615.841 uV, v_off_fin = 2611.857 uV 16:34:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.432 uVs 16:34:13 Integrated Voltage Measurement... 16:34:22 Voltage Offset Correction: v_off_ini = 2596.747 uV, v_off_fin = 2585.349 uV 16:34:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.946 uVs 16:34:22 Integrated Voltage Measurement... 16:34:31 Voltage Offset Correction: v_off_ini = 2623.580 uV, v_off_fin = 2621.093 uV 16:34:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.980 uVs 16:34:33 I2X Average and RMS of Measurements VT = -69.071 +- 6.359 uVs I2X = 6.355 +- 0.585 uTm^2 16:34:38 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:34:41 Integrated Voltage Measurement... 16:34:50 Voltage Offset Correction: v_off_ini = 2607.360 uV, v_off_fin = 2597.873 uV 16:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.484 uVs 16:34:50 Integrated Voltage Measurement... 16:34:59 Voltage Offset Correction: v_off_ini = 2586.357 uV, v_off_fin = 2591.891 uV 16:34:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.295 uVs 16:34:59 Integrated Voltage Measurement... 16:35:08 Voltage Offset Correction: v_off_ini = 2592.706 uV, v_off_fin = 2581.325 uV 16:35:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.055 uVs 16:35:08 Integrated Voltage Measurement... 16:35:17 Voltage Offset Correction: v_off_ini = 2581.709 uV, v_off_fin = 2590.011 uV 16:35:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.124 uVs 16:35:17 Integrated Voltage Measurement... 16:35:26 Voltage Offset Correction: v_off_ini = 2601.629 uV, v_off_fin = 2623.578 uV 16:35:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.416 uVs 16:35:26 Integrated Voltage Measurement... 16:35:35 Voltage Offset Correction: v_off_ini = 2598.485 uV, v_off_fin = 2574.424 uV 16:35:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.743 uVs 16:35:38 I2Y Average and RMS of Measurements VT = -279.686 +- 6.603 uVs I2Y = -25.731 +- 0.607 uTm^2 16:35:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:35:50 Integrated Voltage Measurement... 16:35:59 Voltage Offset Correction: v_off_ini = 2607.802 uV, v_off_fin = 2582.043 uV 16:35:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.100 uVs 16:35:59 Integrated Voltage Measurement... 16:36:08 Voltage Offset Correction: v_off_ini = 2566.081 uV, v_off_fin = 2554.742 uV 16:36:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.772 uVs 16:36:08 Integrated Voltage Measurement... 16:36:17 Voltage Offset Correction: v_off_ini = 2584.206 uV, v_off_fin = 2565.263 uV 16:36:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.934 uVs 16:36:17 Integrated Voltage Measurement... 16:36:26 Voltage Offset Correction: v_off_ini = 2575.680 uV, v_off_fin = 2571.038 uV 16:36:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.770 uVs 16:36:26 Integrated Voltage Measurement... 16:36:35 Voltage Offset Correction: v_off_ini = 2577.372 uV, v_off_fin = 2557.615 uV 16:36:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.976 uVs 16:36:35 Integrated Voltage Measurement... 16:36:44 Voltage Offset Correction: v_off_ini = 2561.723 uV, v_off_fin = 2573.559 uV 16:36:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 63.113 uVs 16:36:48 I1X Average and RMS of Measurements VT = -78.444 +- 9.187 uVs I1X = 15.690 +- 1.837 uTm 16:36:50 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:36:55 Integrated Voltage Measurement... 16:37:03 Voltage Offset Correction: v_off_ini = 2579.245 uV, v_off_fin = 2579.874 uV 16:37:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.067 uVs 16:37:04 Integrated Voltage Measurement... 16:37:12 Voltage Offset Correction: v_off_ini = 2577.024 uV, v_off_fin = 2568.933 uV 16:37:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.313 uVs 16:37:13 Integrated Voltage Measurement... 16:37:21 Voltage Offset Correction: v_off_ini = 2574.643 uV, v_off_fin = 2548.013 uV 16:37:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.989 uVs 16:37:22 Integrated Voltage Measurement... 16:37:30 Voltage Offset Correction: v_off_ini = 2556.147 uV, v_off_fin = 2568.422 uV 16:37:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.767 uVs 16:37:31 Integrated Voltage Measurement... 16:37:39 Voltage Offset Correction: v_off_ini = 2564.835 uV, v_off_fin = 2557.873 uV 16:37:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.400 uVs 16:37:40 Integrated Voltage Measurement... 16:37:48 Voltage Offset Correction: v_off_ini = 2545.956 uV, v_off_fin = 2574.708 uV 16:37:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.152 uVs 16:37:53 I1Y Average and RMS of Measurements VT = -211.948 +- 20.504 uVs I1Y = -42.390 +- 4.101 uTm 16:37:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:37:58 Integrated Voltage Measurement... 16:38:07 Voltage Offset Correction: v_off_ini = 2561.715 uV, v_off_fin = 2533.472 uV 16:38:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.410 uVs 16:38:07 Integrated Voltage Measurement... 16:38:16 Voltage Offset Correction: v_off_ini = 2559.869 uV, v_off_fin = 2561.611 uV 16:38:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.527 uVs 16:38:16 Integrated Voltage Measurement... 16:38:25 Voltage Offset Correction: v_off_ini = 2568.254 uV, v_off_fin = 2554.778 uV 16:38:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.419 uVs 16:38:25 Integrated Voltage Measurement... 16:38:34 Voltage Offset Correction: v_off_ini = 2552.468 uV, v_off_fin = 2570.604 uV 16:38:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.422 uVs 16:38:34 Integrated Voltage Measurement... 16:38:43 Voltage Offset Correction: v_off_ini = 2580.434 uV, v_off_fin = 2546.696 uV 16:38:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.549 uVs 16:38:43 Integrated Voltage Measurement... 16:38:52 Voltage Offset Correction: v_off_ini = 2563.949 uV, v_off_fin = 2566.338 uV 16:38:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.222 uVs 16:38:54 I2X Average and RMS of Measurements VT = -75.092 +- 11.240 uVs I2X = 6.908 +- 1.034 uTm^2 16:38:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:38:59 Integrated Voltage Measurement... 16:39:08 Voltage Offset Correction: v_off_ini = 2579.012 uV, v_off_fin = 2543.051 uV 16:39:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.379 uVs 16:39:08 Integrated Voltage Measurement... 16:39:17 Voltage Offset Correction: v_off_ini = 2588.113 uV, v_off_fin = 2573.663 uV 16:39:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.012 uVs 16:39:18 Integrated Voltage Measurement... 16:39:27 Voltage Offset Correction: v_off_ini = 2562.267 uV, v_off_fin = 2576.365 uV 16:39:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.275 uVs 16:39:27 Integrated Voltage Measurement... 16:39:36 Voltage Offset Correction: v_off_ini = 2598.675 uV, v_off_fin = 2589.614 uV 16:39:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.175 uVs 16:39:36 Integrated Voltage Measurement... 16:39:45 Voltage Offset Correction: v_off_ini = 2581.699 uV, v_off_fin = 2575.466 uV 16:39:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.002 uVs 16:39:45 Integrated Voltage Measurement... 16:39:54 Voltage Offset Correction: v_off_ini = 2585.772 uV, v_off_fin = 2592.952 uV 16:39:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.867 uVs 16:39:56 I2Y Average and RMS of Measurements VT = -266.118 +- 13.806 uVs I2Y = -24.483 +- 1.270 uTm^2 16:40:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:40:04 Integrated Voltage Measurement... 16:40:13 Voltage Offset Correction: v_off_ini = 2593.765 uV, v_off_fin = 2581.737 uV 16:40:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.918 uVs 16:40:13 Integrated Voltage Measurement... 16:40:22 Voltage Offset Correction: v_off_ini = 2554.434 uV, v_off_fin = 2590.392 uV 16:40:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 74.674 uVs 16:40:22 Integrated Voltage Measurement... 16:40:31 Voltage Offset Correction: v_off_ini = 2598.441 uV, v_off_fin = 2592.968 uV 16:40:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.024 uVs 16:40:31 Integrated Voltage Measurement... 16:40:40 Voltage Offset Correction: v_off_ini = 2622.155 uV, v_off_fin = 2621.734 uV 16:40:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.459 uVs 16:40:40 Integrated Voltage Measurement... 16:40:49 Voltage Offset Correction: v_off_ini = 2618.004 uV, v_off_fin = 2603.680 uV 16:40:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.142 uVs 16:40:49 Integrated Voltage Measurement... 16:40:58 Voltage Offset Correction: v_off_ini = 2594.095 uV, v_off_fin = 2602.497 uV 16:40:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.698 uVs 16:41:03 I1X Average and RMS of Measurements VT = -89.986 +- 35.279 uVs I1X = 17.998 +- 7.056 uTm 16:41:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:41:09 Integrated Voltage Measurement... 16:41:18 Voltage Offset Correction: v_off_ini = 2641.018 uV, v_off_fin = 2602.882 uV 16:41:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.740 uVs 16:41:18 Integrated Voltage Measurement... 16:41:27 Voltage Offset Correction: v_off_ini = 2610.012 uV, v_off_fin = 2626.987 uV 16:41:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.776 uVs 16:41:27 Integrated Voltage Measurement... 16:41:36 Voltage Offset Correction: v_off_ini = 2617.535 uV, v_off_fin = 2603.023 uV 16:41:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.770 uVs 16:41:36 Integrated Voltage Measurement... 16:41:45 Voltage Offset Correction: v_off_ini = 2597.839 uV, v_off_fin = 2608.990 uV 16:41:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.519 uVs 16:41:45 Integrated Voltage Measurement... 16:41:54 Voltage Offset Correction: v_off_ini = 2631.973 uV, v_off_fin = 2642.592 uV 16:41:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.373 uVs 16:41:54 Integrated Voltage Measurement... 16:42:03 Voltage Offset Correction: v_off_ini = 2624.641 uV, v_off_fin = 2633.247 uV 16:42:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.095 uVs 16:42:07 I1Y Average and RMS of Measurements VT = -216.545 +- 10.119 uVs I1Y = -43.309 +- 2.024 uTm 16:42:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:42:13 Integrated Voltage Measurement... 16:42:22 Voltage Offset Correction: v_off_ini = 2619.995 uV, v_off_fin = 2626.978 uV 16:42:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.358 uVs 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = 2653.357 uV, v_off_fin = 2644.517 uV 16:42:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.655 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = 2603.851 uV, v_off_fin = 2597.214 uV 16:42:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.032 uVs 16:42:40 Integrated Voltage Measurement... 16:42:49 Voltage Offset Correction: v_off_ini = 2634.139 uV, v_off_fin = 2628.988 uV 16:42:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.050 uVs 16:42:49 Integrated Voltage Measurement... 16:42:58 Voltage Offset Correction: v_off_ini = 2635.132 uV, v_off_fin = 2623.605 uV 16:42:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.405 uVs 16:42:58 Integrated Voltage Measurement... 16:43:07 Voltage Offset Correction: v_off_ini = 2614.863 uV, v_off_fin = 2617.063 uV 16:43:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.053 uVs 16:43:09 I2X Average and RMS of Measurements VT = -75.259 +- 4.237 uVs I2X = 6.924 +- 0.390 uTm^2 16:43:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:43:14 Integrated Voltage Measurement... 16:43:23 Voltage Offset Correction: v_off_ini = 2585.758 uV, v_off_fin = 2597.526 uV 16:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.537 uVs 16:43:23 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = 2614.929 uV, v_off_fin = 2604.981 uV 16:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.842 uVs 16:43:32 Integrated Voltage Measurement... 16:43:41 Voltage Offset Correction: v_off_ini = 2598.656 uV, v_off_fin = 2601.779 uV 16:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.041 uVs 16:43:41 Integrated Voltage Measurement... 16:43:50 Voltage Offset Correction: v_off_ini = 2583.477 uV, v_off_fin = 2599.438 uV 16:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.944 uVs 16:43:50 Integrated Voltage Measurement... 16:43:59 Voltage Offset Correction: v_off_ini = 2604.515 uV, v_off_fin = 2598.045 uV 16:43:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.220 uVs 16:43:59 Integrated Voltage Measurement... 16:44:08 Voltage Offset Correction: v_off_ini = 2625.701 uV, v_off_fin = 2594.785 uV 16:44:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.149 uVs 16:44:11 I2Y Average and RMS of Measurements VT = -284.289 +- 5.059 uVs I2Y = -26.155 +- 0.465 uTm^2 16:44:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:19 Integrated Voltage Measurement... 16:44:28 Voltage Offset Correction: v_off_ini = 2563.611 uV, v_off_fin = 2557.047 uV 16:44:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.189 uVs 16:44:28 Integrated Voltage Measurement... 16:44:37 Voltage Offset Correction: v_off_ini = 2570.228 uV, v_off_fin = 2584.075 uV 16:44:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.974 uVs 16:44:37 Integrated Voltage Measurement... 16:44:46 Voltage Offset Correction: v_off_ini = 2573.933 uV, v_off_fin = 2570.932 uV 16:44:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.067 uVs 16:44:46 Integrated Voltage Measurement... 16:44:55 Voltage Offset Correction: v_off_ini = 2589.513 uV, v_off_fin = 2615.265 uV 16:44:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.834 uVs 16:44:55 Integrated Voltage Measurement... 16:45:04 Voltage Offset Correction: v_off_ini = 2603.889 uV, v_off_fin = 2596.737 uV 16:45:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.880 uVs 16:45:04 Integrated Voltage Measurement... 16:45:13 Voltage Offset Correction: v_off_ini = 2560.971 uV, v_off_fin = 2573.361 uV 16:45:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.615 uVs 16:45:17 I1X Average and RMS of Measurements VT = -83.927 +- 5.620 uVs I1X = 16.786 +- 1.124 uTm 16:45:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:24 Integrated Voltage Measurement... 16:45:33 Voltage Offset Correction: v_off_ini = 2587.216 uV, v_off_fin = 2572.995 uV 16:45:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.500 uVs 16:45:33 Integrated Voltage Measurement... 16:45:42 Voltage Offset Correction: v_off_ini = 2547.765 uV, v_off_fin = 2591.411 uV 16:45:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.289 uVs 16:45:42 Integrated Voltage Measurement... 16:45:51 Voltage Offset Correction: v_off_ini = 2562.590 uV, v_off_fin = 2580.626 uV 16:45:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.106 uVs 16:45:51 Integrated Voltage Measurement... 16:46:00 Voltage Offset Correction: v_off_ini = 2606.580 uV, v_off_fin = 2603.784 uV 16:46:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.958 uVs 16:46:00 Integrated Voltage Measurement... 16:46:09 Voltage Offset Correction: v_off_ini = 2601.208 uV, v_off_fin = 2590.689 uV 16:46:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.123 uVs 16:46:09 Integrated Voltage Measurement... 16:46:18 Voltage Offset Correction: v_off_ini = 2600.309 uV, v_off_fin = 2613.080 uV 16:46:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.507 uVs 16:46:22 I1Y Average and RMS of Measurements VT = -211.747 +- 14.564 uVs I1Y = -42.350 +- 2.912 uTm 16:46:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:27 Integrated Voltage Measurement... 16:46:36 Voltage Offset Correction: v_off_ini = 2554.049 uV, v_off_fin = 2557.533 uV 16:46:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -83.210 uVs 16:46:36 Integrated Voltage Measurement... 16:46:45 Voltage Offset Correction: v_off_ini = 2564.038 uV, v_off_fin = 2597.523 uV 16:46:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 101.534 uVs 16:46:45 Integrated Voltage Measurement... 16:46:54 Voltage Offset Correction: v_off_ini = 2591.813 uV, v_off_fin = 2591.780 uV 16:46:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.530 uVs 16:46:54 Integrated Voltage Measurement... 16:47:03 Voltage Offset Correction: v_off_ini = 2600.087 uV, v_off_fin = 2592.989 uV 16:47:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.083 uVs 16:47:03 Integrated Voltage Measurement... 16:47:12 Voltage Offset Correction: v_off_ini = 2550.710 uV, v_off_fin = 2560.037 uV 16:47:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.668 uVs 16:47:12 Integrated Voltage Measurement... 16:47:21 Voltage Offset Correction: v_off_ini = 2612.246 uV, v_off_fin = 2593.025 uV 16:47:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.494 uVs 16:47:24 I2X Average and RMS of Measurements VT = -72.086 +- 16.360 uVs I2X = 6.632 +- 1.505 uTm^2 16:47:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:29 Integrated Voltage Measurement... 16:47:38 Voltage Offset Correction: v_off_ini = 2598.742 uV, v_off_fin = 2582.867 uV 16:47:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.336 uVs 16:47:38 Integrated Voltage Measurement... 16:47:47 Voltage Offset Correction: v_off_ini = 2591.272 uV, v_off_fin = 2583.215 uV 16:47:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.002 uVs 16:47:47 Integrated Voltage Measurement... 16:47:56 Voltage Offset Correction: v_off_ini = 2558.053 uV, v_off_fin = 2566.479 uV 16:47:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -268.511 uVs 16:47:56 Integrated Voltage Measurement... 16:48:05 Voltage Offset Correction: v_off_ini = 2571.694 uV, v_off_fin = 2575.865 uV 16:48:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.894 uVs 16:48:05 Integrated Voltage Measurement... 16:48:14 Voltage Offset Correction: v_off_ini = 2558.824 uV, v_off_fin = 2587.162 uV 16:48:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.860 uVs 16:48:14 Integrated Voltage Measurement... 16:48:23 Voltage Offset Correction: v_off_ini = 2591.280 uV, v_off_fin = 2568.938 uV 16:48:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.260 uVs 16:48:26 I2Y Average and RMS of Measurements VT = -272.811 +- 13.210 uVs I2Y = -25.099 +- 1.215 uTm^2 16:48:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:48:34 Integrated Voltage Measurement... 16:48:43 Voltage Offset Correction: v_off_ini = 2599.698 uV, v_off_fin = 2577.764 uV 16:48:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.429 uVs 16:48:43 Integrated Voltage Measurement... 16:48:52 Voltage Offset Correction: v_off_ini = 2572.477 uV, v_off_fin = 2562.031 uV 16:48:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.988 uVs 16:48:52 Integrated Voltage Measurement... 16:49:01 Voltage Offset Correction: v_off_ini = 2589.927 uV, v_off_fin = 2546.341 uV 16:49:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.559 uVs 16:49:01 Integrated Voltage Measurement... 16:49:10 Voltage Offset Correction: v_off_ini = 2582.499 uV, v_off_fin = 2593.065 uV 16:49:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.632 uVs 16:49:10 Integrated Voltage Measurement... 16:49:19 Voltage Offset Correction: v_off_ini = 2571.736 uV, v_off_fin = 2546.510 uV 16:49:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.893 uVs 16:49:19 Integrated Voltage Measurement... 16:49:28 Voltage Offset Correction: v_off_ini = 2595.288 uV, v_off_fin = 2591.897 uV 16:49:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.409 uVs 16:49:32 I1X Average and RMS of Measurements VT = -70.985 +- 4.543 uVs I1X = 14.197 +- 0.909 uTm 16:49:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:49:39 Integrated Voltage Measurement... 16:49:48 Voltage Offset Correction: v_off_ini = 2590.188 uV, v_off_fin = 2576.336 uV 16:49:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.057 uVs 16:49:48 Integrated Voltage Measurement... 16:49:57 Voltage Offset Correction: v_off_ini = 2607.829 uV, v_off_fin = 2611.376 uV 16:49:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.942 uVs 16:49:57 Integrated Voltage Measurement... 16:50:06 Voltage Offset Correction: v_off_ini = 2593.030 uV, v_off_fin = 2594.940 uV 16:50:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.250 uVs 16:50:06 Integrated Voltage Measurement... 16:50:15 Voltage Offset Correction: v_off_ini = 2619.685 uV, v_off_fin = 2627.322 uV 16:50:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.567 uVs 16:50:15 Integrated Voltage Measurement... 16:50:24 Voltage Offset Correction: v_off_ini = 2616.512 uV, v_off_fin = 2604.244 uV 16:50:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.364 uVs 16:50:24 Integrated Voltage Measurement... 16:50:33 Voltage Offset Correction: v_off_ini = 2575.337 uV, v_off_fin = 2609.655 uV 16:50:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.732 uVs 16:50:37 I1Y Average and RMS of Measurements VT = -213.152 +- 5.268 uVs I1Y = -42.629 +- 1.052 uTm 16:50:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:50:42 Integrated Voltage Measurement... 16:50:51 Voltage Offset Correction: v_off_ini = 2596.852 uV, v_off_fin = 2599.277 uV 16:50:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.306 uVs 16:50:51 Integrated Voltage Measurement... 16:51:00 Voltage Offset Correction: v_off_ini = 2598.709 uV, v_off_fin = 2600.650 uV 16:51:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.718 uVs 16:51:00 Integrated Voltage Measurement... 16:51:09 Voltage Offset Correction: v_off_ini = 2607.815 uV, v_off_fin = 2586.169 uV 16:51:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.089 uVs 16:51:09 Integrated Voltage Measurement... 16:51:18 Voltage Offset Correction: v_off_ini = 2591.195 uV, v_off_fin = 2599.815 uV 16:51:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.986 uVs 16:51:18 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 2597.782 uV, v_off_fin = 2591.428 uV 16:51:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.353 uVs 16:51:27 Integrated Voltage Measurement... 16:51:36 Voltage Offset Correction: v_off_ini = 2592.954 uV, v_off_fin = 2593.888 uV 16:51:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.167 uVs 16:51:39 I2X Average and RMS of Measurements VT = -94.770 +- 1.775 uVs I2X = 8.719 +- 0.163 uTm^2 16:51:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:51:44 Integrated Voltage Measurement... 16:51:53 Voltage Offset Correction: v_off_ini = 2606.383 uV, v_off_fin = 2577.088 uV 16:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.617 uVs 16:51:53 Integrated Voltage Measurement... 16:52:02 Voltage Offset Correction: v_off_ini = 2564.128 uV, v_off_fin = 2557.265 uV 16:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.171 uVs 16:52:02 Integrated Voltage Measurement... 16:52:11 Voltage Offset Correction: v_off_ini = 2571.612 uV, v_off_fin = 2568.253 uV 16:52:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.008 uVs 16:52:11 Integrated Voltage Measurement... 16:52:20 Voltage Offset Correction: v_off_ini = 2558.089 uV, v_off_fin = 2560.432 uV 16:52:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.997 uVs 16:52:20 Integrated Voltage Measurement... 16:52:29 Voltage Offset Correction: v_off_ini = 2565.631 uV, v_off_fin = 2569.026 uV 16:52:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.011 uVs 16:52:29 Integrated Voltage Measurement... 16:52:38 Voltage Offset Correction: v_off_ini = 2552.457 uV, v_off_fin = 2552.898 uV 16:52:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.580 uVs 16:52:40 I2Y Average and RMS of Measurements VT = -275.897 +- 4.045 uVs I2Y = -25.383 +- 0.372 uTm^2 16:52:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:52:49 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = 2569.785 uV, v_off_fin = 2598.206 uV 16:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.400 uVs 16:52:58 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = 2550.439 uV, v_off_fin = 2522.499 uV 16:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.265 uVs 16:53:07 Integrated Voltage Measurement... 16:53:16 Voltage Offset Correction: v_off_ini = 2548.394 uV, v_off_fin = 2584.599 uV 16:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.328 uVs 16:53:16 Integrated Voltage Measurement... 16:53:25 Voltage Offset Correction: v_off_ini = 2556.596 uV, v_off_fin = 2570.373 uV 16:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 69.095 uVs 16:53:25 Integrated Voltage Measurement... 16:53:34 Voltage Offset Correction: v_off_ini = 2565.271 uV, v_off_fin = 2569.794 uV 16:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.214 uVs 16:53:34 Integrated Voltage Measurement... 16:53:43 Voltage Offset Correction: v_off_ini = 2572.038 uV, v_off_fin = 2570.436 uV 16:53:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.330 uVs 16:53:47 I1X Average and RMS of Measurements VT = -73.272 +- 12.771 uVs I1X = 14.655 +- 2.554 uTm 16:53:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:53:54 Integrated Voltage Measurement... 16:54:03 Voltage Offset Correction: v_off_ini = 2555.518 uV, v_off_fin = 2546.621 uV 16:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.189 uVs 16:54:03 Integrated Voltage Measurement... 16:54:12 Voltage Offset Correction: v_off_ini = 2538.127 uV, v_off_fin = 2554.712 uV 16:54:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.304 uVs 16:54:12 Integrated Voltage Measurement... 16:54:21 Voltage Offset Correction: v_off_ini = 2549.065 uV, v_off_fin = 2533.268 uV 16:54:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.218 uVs 16:54:21 Integrated Voltage Measurement... 16:54:30 Voltage Offset Correction: v_off_ini = 2539.681 uV, v_off_fin = 2564.187 uV 16:54:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.739 uVs 16:54:30 Integrated Voltage Measurement... 16:54:39 Voltage Offset Correction: v_off_ini = 2560.196 uV, v_off_fin = 2548.128 uV 16:54:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.479 uVs 16:54:39 Integrated Voltage Measurement... 16:54:48 Voltage Offset Correction: v_off_ini = 2567.611 uV, v_off_fin = 2580.961 uV 16:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.562 uVs 16:54:52 I1Y Average and RMS of Measurements VT = -212.749 +- 7.871 uVs I1Y = -42.549 +- 1.573 uTm 16:54:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:54:57 Integrated Voltage Measurement... 16:55:06 Voltage Offset Correction: v_off_ini = 2560.041 uV, v_off_fin = 2540.292 uV 16:55:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.536 uVs 16:55:06 Integrated Voltage Measurement... 16:55:15 Voltage Offset Correction: v_off_ini = 2580.107 uV, v_off_fin = 2596.208 uV 16:55:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.786 uVs 16:55:15 Integrated Voltage Measurement... 16:55:24 Voltage Offset Correction: v_off_ini = 2579.770 uV, v_off_fin = 2558.091 uV 16:55:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.910 uVs 16:55:24 Integrated Voltage Measurement... 16:55:33 Voltage Offset Correction: v_off_ini = 2578.610 uV, v_off_fin = 2589.383 uV 16:55:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.588 uVs 16:55:33 Integrated Voltage Measurement... 16:55:42 Voltage Offset Correction: v_off_ini = 2560.025 uV, v_off_fin = 2541.326 uV 16:55:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.597 uVs 16:55:42 Integrated Voltage Measurement... 16:55:51 Voltage Offset Correction: v_off_ini = 2581.853 uV, v_off_fin = 2594.600 uV 16:55:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.117 uVs 16:55:53 I2X Average and RMS of Measurements VT = -68.256 +- 3.190 uVs I2X = 6.280 +- 0.293 uTm^2 16:55:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:55:59 Integrated Voltage Measurement... 16:56:08 Voltage Offset Correction: v_off_ini = 2605.106 uV, v_off_fin = 2592.039 uV 16:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.639 uVs 16:56:08 Integrated Voltage Measurement... 16:56:17 Voltage Offset Correction: v_off_ini = 2585.047 uV, v_off_fin = 2570.359 uV 16:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.636 uVs 16:56:17 Integrated Voltage Measurement... 16:56:26 Voltage Offset Correction: v_off_ini = 2541.015 uV, v_off_fin = 2545.439 uV 16:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.583 uVs 16:56:26 Integrated Voltage Measurement... 16:56:35 Voltage Offset Correction: v_off_ini = 2528.266 uV, v_off_fin = 2556.869 uV 16:56:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.968 uVs 16:56:35 Integrated Voltage Measurement... 16:56:44 Voltage Offset Correction: v_off_ini = 2554.163 uV, v_off_fin = 2546.204 uV 16:56:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.210 uVs 16:56:44 Integrated Voltage Measurement... 16:56:53 Voltage Offset Correction: v_off_ini = 2546.081 uV, v_off_fin = 2509.984 uV 16:56:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.684 uVs 16:56:55 I2Y Average and RMS of Measurements VT = -266.287 +- 12.850 uVs I2Y = -24.498 +- 1.182 uTm^2 16:57:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm