SLAC Magnetic Measurements Date: 07-21-2026 Time: 15:30:46 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16335 Dataset Number: 1 Run Purpose: Final Results Run Type: Run Number: 5 Measurement Device: Stretched Wire Operator: YL Comment: 15:30:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:30:56 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:30:58 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:30:59 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:31:01 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:31:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:27 Integrated Voltage Measurement... 15:31:35 Voltage Offset Correction: v_off_ini = 2797.009 uV, v_off_fin = 2792.240 uV 15:31:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -143.518 uVs 15:31:36 Integrated Voltage Measurement... 15:31:45 Voltage Offset Correction: v_off_ini = 2808.465 uV, v_off_fin = 2797.190 uV 15:31:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.088 uVs 15:31:45 Integrated Voltage Measurement... 15:31:54 Voltage Offset Correction: v_off_ini = 2773.135 uV, v_off_fin = 2758.364 uV 15:31:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.416 uVs 15:31:54 Integrated Voltage Measurement... 15:32:03 Voltage Offset Correction: v_off_ini = 2769.519 uV, v_off_fin = 2786.095 uV 15:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 139.656 uVs 15:32:03 Integrated Voltage Measurement... 15:32:12 Voltage Offset Correction: v_off_ini = 2769.707 uV, v_off_fin = 2783.615 uV 15:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.299 uVs 15:32:12 Integrated Voltage Measurement... 15:32:21 Voltage Offset Correction: v_off_ini = 2776.221 uV, v_off_fin = 2776.741 uV 15:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 135.356 uVs 15:32:25 I1X Average and RMS of Measurements VT = -137.889 +- 2.811 uVs I1X = 27.579 +- 0.562 uTm 15:32:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:32:32 Integrated Voltage Measurement... 15:32:40 Voltage Offset Correction: v_off_ini = 2789.550 uV, v_off_fin = 2789.398 uV 15:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.649 uVs 15:32:40 Integrated Voltage Measurement... 15:32:49 Voltage Offset Correction: v_off_ini = 2778.247 uV, v_off_fin = 2803.773 uV 15:32:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.223 uVs 15:32:49 Integrated Voltage Measurement... 15:32:58 Voltage Offset Correction: v_off_ini = 2788.588 uV, v_off_fin = 2760.665 uV 15:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.984 uVs 15:32:58 Integrated Voltage Measurement... 15:33:07 Voltage Offset Correction: v_off_ini = 2757.928 uV, v_off_fin = 2786.186 uV 15:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.572 uVs 15:33:07 Integrated Voltage Measurement... 15:33:16 Voltage Offset Correction: v_off_ini = 2770.990 uV, v_off_fin = 2762.191 uV 15:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.351 uVs 15:33:16 Integrated Voltage Measurement... 15:33:25 Voltage Offset Correction: v_off_ini = 2784.518 uV, v_off_fin = 2773.958 uV 15:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.043 uVs 15:33:30 I1Y Average and RMS of Measurements VT = -239.137 +- 11.995 uVs I1Y = -47.828 +- 2.400 uTm 15:33:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:37 Integrated Voltage Measurement... 15:33:46 Voltage Offset Correction: v_off_ini = 2759.944 uV, v_off_fin = 2768.045 uV 15:33:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.361 uVs 15:33:46 Integrated Voltage Measurement... 15:33:55 Voltage Offset Correction: v_off_ini = 2779.475 uV, v_off_fin = 2799.977 uV 15:33:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.666 uVs 15:33:55 Integrated Voltage Measurement... 15:34:04 Voltage Offset Correction: v_off_ini = 2775.318 uV, v_off_fin = 2797.094 uV 15:34:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -130.937 uVs 15:34:04 Integrated Voltage Measurement... 15:34:13 Voltage Offset Correction: v_off_ini = 2784.741 uV, v_off_fin = 2797.488 uV 15:34:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.362 uVs 15:34:13 Integrated Voltage Measurement... 15:34:22 Voltage Offset Correction: v_off_ini = 2792.931 uV, v_off_fin = 2781.013 uV 15:34:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -124.132 uVs 15:34:22 Integrated Voltage Measurement... 15:34:31 Voltage Offset Correction: v_off_ini = 2753.393 uV, v_off_fin = 2796.508 uV 15:34:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.199 uVs 15:34:34 I2X Average and RMS of Measurements VT = -105.443 +- 9.856 uVs I2X = 9.701 +- 0.907 uTm^2 15:34:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:41 Integrated Voltage Measurement... 15:34:50 Voltage Offset Correction: v_off_ini = 2803.102 uV, v_off_fin = 2793.587 uV 15:34:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.543 uVs 15:34:50 Integrated Voltage Measurement... 15:34:59 Voltage Offset Correction: v_off_ini = 2802.838 uV, v_off_fin = 2806.385 uV 15:34:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.598 uVs 15:35:00 Integrated Voltage Measurement... 15:35:08 Voltage Offset Correction: v_off_ini = 2833.242 uV, v_off_fin = 2804.294 uV 15:35:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.215 uVs 15:35:09 Integrated Voltage Measurement... 15:35:17 Voltage Offset Correction: v_off_ini = 2807.262 uV, v_off_fin = 2823.621 uV 15:35:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.772 uVs 15:35:18 Integrated Voltage Measurement... 15:35:27 Voltage Offset Correction: v_off_ini = 2782.560 uV, v_off_fin = 2812.492 uV 15:35:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.357 uVs 15:35:27 Integrated Voltage Measurement... 15:35:36 Voltage Offset Correction: v_off_ini = 2801.368 uV, v_off_fin = 2816.179 uV 15:35:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.101 uVs 15:35:38 I2Y Average and RMS of Measurements VT = -265.431 +- 2.279 uVs I2Y = -24.420 +- 0.210 uTm^2 15:35:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:53 Integrated Voltage Measurement... 15:36:02 Voltage Offset Correction: v_off_ini = 2818.548 uV, v_off_fin = 2799.182 uV 15:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -169.409 uVs 15:36:02 Integrated Voltage Measurement... 15:36:11 Voltage Offset Correction: v_off_ini = 2786.592 uV, v_off_fin = 2821.410 uV 15:36:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.083 uVs 15:36:11 Integrated Voltage Measurement... 15:36:20 Voltage Offset Correction: v_off_ini = 2819.791 uV, v_off_fin = 2841.358 uV 15:36:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -167.011 uVs 15:36:20 Integrated Voltage Measurement... 15:36:29 Voltage Offset Correction: v_off_ini = 2862.742 uV, v_off_fin = 2862.112 uV 15:36:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.481 uVs 15:36:29 Integrated Voltage Measurement... 15:36:38 Voltage Offset Correction: v_off_ini = 2867.037 uV, v_off_fin = 2847.238 uV 15:36:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.481 uVs 15:36:38 Integrated Voltage Measurement... 15:36:47 Voltage Offset Correction: v_off_ini = 2854.996 uV, v_off_fin = 2874.585 uV 15:36:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.193 uVs 15:36:51 I1X Average and RMS of Measurements VT = -153.276 +- 8.375 uVs I1X = 30.656 +- 1.675 uTm 15:36:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:58 Integrated Voltage Measurement... 15:37:07 Voltage Offset Correction: v_off_ini = 2873.166 uV, v_off_fin = 2861.621 uV 15:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.685 uVs 15:37:07 Integrated Voltage Measurement... 15:37:16 Voltage Offset Correction: v_off_ini = 2863.702 uV, v_off_fin = 2857.993 uV 15:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.767 uVs 15:37:16 Integrated Voltage Measurement... 15:37:25 Voltage Offset Correction: v_off_ini = 2858.350 uV, v_off_fin = 2839.583 uV 15:37:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.901 uVs 15:37:25 Integrated Voltage Measurement... 15:37:34 Voltage Offset Correction: v_off_ini = 2851.517 uV, v_off_fin = 2877.097 uV 15:37:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.303 uVs 15:37:34 Integrated Voltage Measurement... 15:37:43 Voltage Offset Correction: v_off_ini = 2854.630 uV, v_off_fin = 2855.337 uV 15:37:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.698 uVs 15:37:43 Integrated Voltage Measurement... 15:37:52 Voltage Offset Correction: v_off_ini = 2846.454 uV, v_off_fin = 2872.169 uV 15:37:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.574 uVs 15:37:56 I1Y Average and RMS of Measurements VT = -226.988 +- 8.820 uVs I1Y = -45.398 +- 1.764 uTm 15:38:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:04 Integrated Voltage Measurement... 15:38:13 Voltage Offset Correction: v_off_ini = 2844.350 uV, v_off_fin = 2850.947 uV 15:38:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -98.623 uVs 15:38:13 Integrated Voltage Measurement... 15:38:22 Voltage Offset Correction: v_off_ini = 2850.755 uV, v_off_fin = 2849.313 uV 15:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.746 uVs 15:38:22 Integrated Voltage Measurement... 15:38:31 Voltage Offset Correction: v_off_ini = 2868.017 uV, v_off_fin = 2875.384 uV 15:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.835 uVs 15:38:31 Integrated Voltage Measurement... 15:38:40 Voltage Offset Correction: v_off_ini = 2873.169 uV, v_off_fin = 2869.625 uV 15:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.629 uVs 15:38:40 Integrated Voltage Measurement... 15:38:49 Voltage Offset Correction: v_off_ini = 2844.216 uV, v_off_fin = 2836.573 uV 15:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.028 uVs 15:38:49 Integrated Voltage Measurement... 15:38:58 Voltage Offset Correction: v_off_ini = 2844.597 uV, v_off_fin = 2858.304 uV 15:38:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.026 uVs 15:39:00 I2X Average and RMS of Measurements VT = -118.481 +- 7.833 uVs I2X = 10.900 +- 0.721 uTm^2 15:39:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:39:08 Integrated Voltage Measurement... 15:39:17 Voltage Offset Correction: v_off_ini = 2821.699 uV, v_off_fin = 2839.350 uV 15:39:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.436 uVs 15:39:17 Integrated Voltage Measurement... 15:39:26 Voltage Offset Correction: v_off_ini = 2862.265 uV, v_off_fin = 2873.920 uV 15:39:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.059 uVs 15:39:26 Integrated Voltage Measurement... 15:39:35 Voltage Offset Correction: v_off_ini = 2864.995 uV, v_off_fin = 2866.336 uV 15:39:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.262 uVs 15:39:35 Integrated Voltage Measurement... 15:39:44 Voltage Offset Correction: v_off_ini = 2873.773 uV, v_off_fin = 2863.761 uV 15:39:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.896 uVs 15:39:44 Integrated Voltage Measurement... 15:39:53 Voltage Offset Correction: v_off_ini = 2869.570 uV, v_off_fin = 2874.356 uV 15:39:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.712 uVs 15:39:53 Integrated Voltage Measurement... 15:40:02 Voltage Offset Correction: v_off_ini = 2864.884 uV, v_off_fin = 2873.124 uV 15:40:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.416 uVs 15:40:04 I2Y Average and RMS of Measurements VT = -237.130 +- 4.234 uVs I2Y = -21.816 +- 0.390 uTm^2 15:40:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:40:19 Integrated Voltage Measurement... 15:40:28 Voltage Offset Correction: v_off_ini = 2876.598 uV, v_off_fin = 2856.036 uV 15:40:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.522 uVs 15:40:28 Integrated Voltage Measurement... 15:40:37 Voltage Offset Correction: v_off_ini = 2864.030 uV, v_off_fin = 2860.462 uV 15:40:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.482 uVs 15:40:37 Integrated Voltage Measurement... 15:40:46 Voltage Offset Correction: v_off_ini = 2877.310 uV, v_off_fin = 2826.586 uV 15:40:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -214.058 uVs 15:40:46 Integrated Voltage Measurement... 15:40:55 Voltage Offset Correction: v_off_ini = 2872.471 uV, v_off_fin = 2847.837 uV 15:40:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.543 uVs 15:40:55 Integrated Voltage Measurement... 15:41:04 Voltage Offset Correction: v_off_ini = 2855.779 uV, v_off_fin = 2881.834 uV 15:41:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.197 uVs 15:41:04 Integrated Voltage Measurement... 15:41:13 Voltage Offset Correction: v_off_ini = 2894.312 uV, v_off_fin = 2883.645 uV 15:41:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.440 uVs 15:41:18 I1X Average and RMS of Measurements VT = -175.207 +- 9.307 uVs I1X = 35.041 +- 1.861 uTm 15:41:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:41:24 Integrated Voltage Measurement... 15:41:33 Voltage Offset Correction: v_off_ini = 2858.385 uV, v_off_fin = 2856.854 uV 15:41:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -226.094 uVs 15:41:33 Integrated Voltage Measurement... 15:41:42 Voltage Offset Correction: v_off_ini = 2887.448 uV, v_off_fin = 2882.071 uV 15:41:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.891 uVs 15:41:42 Integrated Voltage Measurement... 15:41:51 Voltage Offset Correction: v_off_ini = 2862.794 uV, v_off_fin = 2870.634 uV 15:41:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.385 uVs 15:41:51 Integrated Voltage Measurement... 15:42:00 Voltage Offset Correction: v_off_ini = 2876.567 uV, v_off_fin = 2915.493 uV 15:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.017 uVs 15:42:00 Integrated Voltage Measurement... 15:42:09 Voltage Offset Correction: v_off_ini = 2875.332 uV, v_off_fin = 2856.263 uV 15:42:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.346 uVs 15:42:09 Integrated Voltage Measurement... 15:42:18 Voltage Offset Correction: v_off_ini = 2891.295 uV, v_off_fin = 2910.845 uV 15:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.414 uVs 15:42:22 I1Y Average and RMS of Measurements VT = -222.858 +- 6.079 uVs I1Y = -44.571 +- 1.214 uTm 15:42:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:42:30 Integrated Voltage Measurement... 15:42:39 Voltage Offset Correction: v_off_ini = 2896.198 uV, v_off_fin = 2897.569 uV 15:42:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -94.153 uVs 15:42:39 Integrated Voltage Measurement... 15:42:48 Voltage Offset Correction: v_off_ini = 2938.218 uV, v_off_fin = 2950.983 uV 15:42:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.711 uVs 15:42:48 Integrated Voltage Measurement... 15:42:57 Voltage Offset Correction: v_off_ini = 2954.940 uV, v_off_fin = 2912.519 uV 15:42:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.133 uVs 15:42:57 Integrated Voltage Measurement... 15:43:06 Voltage Offset Correction: v_off_ini = 2920.551 uV, v_off_fin = 2925.390 uV 15:43:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.655 uVs 15:43:06 Integrated Voltage Measurement... 15:43:15 Voltage Offset Correction: v_off_ini = 2891.019 uV, v_off_fin = 2880.428 uV 15:43:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.913 uVs 15:43:15 Integrated Voltage Measurement... 15:43:24 Voltage Offset Correction: v_off_ini = 2898.465 uV, v_off_fin = 2919.295 uV 15:43:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 143.765 uVs 15:43:27 I2X Average and RMS of Measurements VT = -124.222 +- 14.661 uVs I2X = 11.429 +- 1.349 uTm^2 15:43:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:43:34 Integrated Voltage Measurement... 15:43:43 Voltage Offset Correction: v_off_ini = 2891.238 uV, v_off_fin = 2863.978 uV 15:43:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.653 uVs 15:43:43 Integrated Voltage Measurement... 15:43:52 Voltage Offset Correction: v_off_ini = 2877.575 uV, v_off_fin = 2854.093 uV 15:43:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.518 uVs 15:43:52 Integrated Voltage Measurement... 15:44:01 Voltage Offset Correction: v_off_ini = 2872.638 uV, v_off_fin = 2887.340 uV 15:44:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.593 uVs 15:44:01 Integrated Voltage Measurement... 15:44:10 Voltage Offset Correction: v_off_ini = 2856.829 uV, v_off_fin = 2862.547 uV 15:44:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.437 uVs 15:44:10 Integrated Voltage Measurement... 15:44:19 Voltage Offset Correction: v_off_ini = 2852.222 uV, v_off_fin = 2872.366 uV 15:44:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.032 uVs 15:44:19 Integrated Voltage Measurement... 15:44:28 Voltage Offset Correction: v_off_ini = 2849.173 uV, v_off_fin = 2851.719 uV 15:44:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.730 uVs 15:44:31 I2Y Average and RMS of Measurements VT = -227.494 +- 7.614 uVs I2Y = -20.929 +- 0.701 uTm^2 15:44:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:44:46 Integrated Voltage Measurement... 15:44:55 Voltage Offset Correction: v_off_ini = 2860.514 uV, v_off_fin = 2851.463 uV 15:44:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.670 uVs 15:44:55 Integrated Voltage Measurement... 15:45:04 Voltage Offset Correction: v_off_ini = 2867.447 uV, v_off_fin = 2878.495 uV 15:45:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 183.596 uVs 15:45:04 Integrated Voltage Measurement... 15:45:13 Voltage Offset Correction: v_off_ini = 2901.508 uV, v_off_fin = 2895.273 uV 15:45:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.382 uVs 15:45:13 Integrated Voltage Measurement... 15:45:22 Voltage Offset Correction: v_off_ini = 2898.936 uV, v_off_fin = 2891.033 uV 15:45:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.396 uVs 15:45:22 Integrated Voltage Measurement... 15:45:31 Voltage Offset Correction: v_off_ini = 2885.788 uV, v_off_fin = 2883.702 uV 15:45:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.069 uVs 15:45:31 Integrated Voltage Measurement... 15:45:40 Voltage Offset Correction: v_off_ini = 2889.383 uV, v_off_fin = 2890.445 uV 15:45:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.125 uVs 15:45:44 I1X Average and RMS of Measurements VT = -164.040 +- 3.431 uVs I1X = 32.809 +- 0.688 uTm 15:45:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:45:51 Integrated Voltage Measurement... 15:46:00 Voltage Offset Correction: v_off_ini = 2891.567 uV, v_off_fin = 2853.106 uV 15:46:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -213.763 uVs 15:46:00 Integrated Voltage Measurement... 15:46:09 Voltage Offset Correction: v_off_ini = 2883.202 uV, v_off_fin = 2894.754 uV 15:46:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.394 uVs 15:46:09 Integrated Voltage Measurement... 15:46:18 Voltage Offset Correction: v_off_ini = 2895.034 uV, v_off_fin = 2874.484 uV 15:46:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.825 uVs 15:46:18 Integrated Voltage Measurement... 15:46:27 Voltage Offset Correction: v_off_ini = 2863.244 uV, v_off_fin = 2876.476 uV 15:46:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.859 uVs 15:46:27 Integrated Voltage Measurement... 15:46:36 Voltage Offset Correction: v_off_ini = 2882.220 uV, v_off_fin = 2863.377 uV 15:46:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.793 uVs 15:46:36 Integrated Voltage Measurement... 15:46:45 Voltage Offset Correction: v_off_ini = 2881.263 uV, v_off_fin = 2872.032 uV 15:46:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.751 uVs 15:46:49 I1Y Average and RMS of Measurements VT = -209.397 +- 5.376 uVs I1Y = -41.880 +- 1.074 uTm 15:46:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:57 Integrated Voltage Measurement... 15:47:06 Voltage Offset Correction: v_off_ini = 2878.049 uV, v_off_fin = 2857.942 uV 15:47:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -159.237 uVs 15:47:06 Integrated Voltage Measurement... 15:47:15 Voltage Offset Correction: v_off_ini = 2855.597 uV, v_off_fin = 2874.524 uV 15:47:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.621 uVs 15:47:15 Integrated Voltage Measurement... 15:47:24 Voltage Offset Correction: v_off_ini = 2850.710 uV, v_off_fin = 2837.167 uV 15:47:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -159.677 uVs 15:47:24 Integrated Voltage Measurement... 15:47:33 Voltage Offset Correction: v_off_ini = 2870.878 uV, v_off_fin = 2879.688 uV 15:47:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.480 uVs 15:47:33 Integrated Voltage Measurement... 15:47:42 Voltage Offset Correction: v_off_ini = 2817.576 uV, v_off_fin = 2835.575 uV 15:47:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -167.405 uVs 15:47:42 Integrated Voltage Measurement... 15:47:51 Voltage Offset Correction: v_off_ini = 2858.221 uV, v_off_fin = 2862.350 uV 15:47:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.942 uVs 15:47:53 I2X Average and RMS of Measurements VT = -147.727 +- 2.088 uVs I2X = 13.591 +- 0.193 uTm^2 15:47:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:01 Integrated Voltage Measurement... 15:48:10 Voltage Offset Correction: v_off_ini = 2830.552 uV, v_off_fin = 2845.188 uV 15:48:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.124 uVs 15:48:10 Integrated Voltage Measurement... 15:48:19 Voltage Offset Correction: v_off_ini = 2840.919 uV, v_off_fin = 2845.043 uV 15:48:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.758 uVs 15:48:19 Integrated Voltage Measurement... 15:48:28 Voltage Offset Correction: v_off_ini = 2864.512 uV, v_off_fin = 2878.062 uV 15:48:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.057 uVs 15:48:28 Integrated Voltage Measurement... 15:48:37 Voltage Offset Correction: v_off_ini = 2882.843 uV, v_off_fin = 2871.954 uV 15:48:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.645 uVs 15:48:37 Integrated Voltage Measurement... 15:48:46 Voltage Offset Correction: v_off_ini = 2874.418 uV, v_off_fin = 2877.821 uV 15:48:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.153 uVs 15:48:46 Integrated Voltage Measurement... 15:48:55 Voltage Offset Correction: v_off_ini = 2852.568 uV, v_off_fin = 2845.706 uV 15:48:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.981 uVs 15:48:57 I2Y Average and RMS of Measurements VT = -204.286 +- 10.204 uVs I2Y = -18.795 +- 0.938 uTm^2 15:49:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:12 Integrated Voltage Measurement... 15:49:21 Voltage Offset Correction: v_off_ini = 2860.686 uV, v_off_fin = 2842.659 uV 15:49:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -195.320 uVs 15:49:21 Integrated Voltage Measurement... 15:49:30 Voltage Offset Correction: v_off_ini = 2843.409 uV, v_off_fin = 2859.588 uV 15:49:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 183.869 uVs 15:49:30 Integrated Voltage Measurement... 15:49:39 Voltage Offset Correction: v_off_ini = 2823.310 uV, v_off_fin = 2847.220 uV 15:49:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -198.897 uVs 15:49:39 Integrated Voltage Measurement... 15:49:48 Voltage Offset Correction: v_off_ini = 2857.423 uV, v_off_fin = 2863.252 uV 15:49:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.353 uVs 15:49:48 Integrated Voltage Measurement... 15:49:57 Voltage Offset Correction: v_off_ini = 2851.871 uV, v_off_fin = 2842.388 uV 15:49:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -160.980 uVs 15:49:57 Integrated Voltage Measurement... 15:50:06 Voltage Offset Correction: v_off_ini = 2885.013 uV, v_off_fin = 2871.682 uV 15:50:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.905 uVs 15:50:11 I1X Average and RMS of Measurements VT = -175.887 +- 9.921 uVs I1X = 35.179 +- 1.986 uTm 15:50:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:17 Integrated Voltage Measurement... 15:50:26 Voltage Offset Correction: v_off_ini = 2884.581 uV, v_off_fin = 2884.231 uV 15:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -181.635 uVs 15:50:26 Integrated Voltage Measurement... 15:50:35 Voltage Offset Correction: v_off_ini = 2885.904 uV, v_off_fin = 2874.080 uV 15:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.981 uVs 15:50:35 Integrated Voltage Measurement... 15:50:44 Voltage Offset Correction: v_off_ini = 2840.576 uV, v_off_fin = 2830.994 uV 15:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.109 uVs 15:50:44 Integrated Voltage Measurement... 15:50:53 Voltage Offset Correction: v_off_ini = 2846.979 uV, v_off_fin = 2866.340 uV 15:50:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.810 uVs 15:50:53 Integrated Voltage Measurement... 15:51:02 Voltage Offset Correction: v_off_ini = 2857.818 uV, v_off_fin = 2869.150 uV 15:51:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.510 uVs 15:51:02 Integrated Voltage Measurement... 15:51:11 Voltage Offset Correction: v_off_ini = 2869.874 uV, v_off_fin = 2892.590 uV 15:51:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.447 uVs 15:51:15 I1Y Average and RMS of Measurements VT = -195.749 +- 4.251 uVs I1Y = -39.150 +- 0.848 uTm 15:51:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:51:23 Integrated Voltage Measurement... 15:51:32 Voltage Offset Correction: v_off_ini = 2877.486 uV, v_off_fin = 2870.957 uV 15:51:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -142.397 uVs 15:51:32 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = 2852.890 uV, v_off_fin = 2851.526 uV 15:51:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 132.718 uVs 15:51:41 Integrated Voltage Measurement... 15:51:50 Voltage Offset Correction: v_off_ini = 2846.511 uV, v_off_fin = 2837.312 uV 15:51:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -155.785 uVs 15:51:50 Integrated Voltage Measurement... 15:51:59 Voltage Offset Correction: v_off_ini = 2849.103 uV, v_off_fin = 2860.787 uV 15:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 163.727 uVs 15:51:59 Integrated Voltage Measurement... 15:52:08 Voltage Offset Correction: v_off_ini = 2834.784 uV, v_off_fin = 2818.012 uV 15:52:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.353 uVs 15:52:08 Integrated Voltage Measurement... 15:52:17 Voltage Offset Correction: v_off_ini = 2836.726 uV, v_off_fin = 2844.563 uV 15:52:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 120.794 uVs 15:52:20 I2X Average and RMS of Measurements VT = -145.296 +- 10.233 uVs I2X = 13.368 +- 0.942 uTm^2 15:52:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:27 Integrated Voltage Measurement... 15:52:36 Voltage Offset Correction: v_off_ini = 2823.986 uV, v_off_fin = 2855.293 uV 15:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.554 uVs 15:52:36 Integrated Voltage Measurement... 15:52:45 Voltage Offset Correction: v_off_ini = 2844.090 uV, v_off_fin = 2855.534 uV 15:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.881 uVs 15:52:45 Integrated Voltage Measurement... 15:52:54 Voltage Offset Correction: v_off_ini = 2845.191 uV, v_off_fin = 2872.287 uV 15:52:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.968 uVs 15:52:54 Integrated Voltage Measurement... 15:53:03 Voltage Offset Correction: v_off_ini = 2854.137 uV, v_off_fin = 2832.949 uV 15:53:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.761 uVs 15:53:03 Integrated Voltage Measurement... 15:53:12 Voltage Offset Correction: v_off_ini = 2856.238 uV, v_off_fin = 2829.855 uV 15:53:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.979 uVs 15:53:12 Integrated Voltage Measurement... 15:53:21 Voltage Offset Correction: v_off_ini = 2864.446 uV, v_off_fin = 2867.926 uV 15:53:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.020 uVs 15:53:24 I2Y Average and RMS of Measurements VT = -202.360 +- 7.858 uVs I2Y = -18.617 +- 0.723 uTm^2 15:53:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:39 Integrated Voltage Measurement... 15:53:48 Voltage Offset Correction: v_off_ini = 2853.657 uV, v_off_fin = 2853.386 uV 15:53:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -210.961 uVs 15:53:48 Integrated Voltage Measurement... 15:53:57 Voltage Offset Correction: v_off_ini = 2857.154 uV, v_off_fin = 2836.369 uV 15:53:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 171.566 uVs 15:53:57 Integrated Voltage Measurement... 15:54:06 Voltage Offset Correction: v_off_ini = 2843.919 uV, v_off_fin = 2838.077 uV 15:54:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -189.122 uVs 15:54:06 Integrated Voltage Measurement... 15:54:15 Voltage Offset Correction: v_off_ini = 2852.622 uV, v_off_fin = 2846.148 uV 15:54:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.820 uVs 15:54:15 Integrated Voltage Measurement... 15:54:24 Voltage Offset Correction: v_off_ini = 2842.899 uV, v_off_fin = 2859.327 uV 15:54:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -206.628 uVs 15:54:24 Integrated Voltage Measurement... 15:54:33 Voltage Offset Correction: v_off_ini = 2846.777 uV, v_off_fin = 2824.088 uV 15:54:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.575 uVs 15:54:37 I1X Average and RMS of Measurements VT = -182.779 +- 7.526 uVs I1X = 36.556 +- 1.505 uTm 15:54:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:44 Integrated Voltage Measurement... 15:54:53 Voltage Offset Correction: v_off_ini = 2802.776 uV, v_off_fin = 2811.247 uV 15:54:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -201.587 uVs 15:54:53 Integrated Voltage Measurement... 15:55:02 Voltage Offset Correction: v_off_ini = 2811.040 uV, v_off_fin = 2819.175 uV 15:55:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.205 uVs 15:55:02 Integrated Voltage Measurement... 15:55:11 Voltage Offset Correction: v_off_ini = 2801.799 uV, v_off_fin = 2777.846 uV 15:55:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.296 uVs 15:55:11 Integrated Voltage Measurement... 15:55:20 Voltage Offset Correction: v_off_ini = 2806.121 uV, v_off_fin = 2814.069 uV 15:55:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.454 uVs 15:55:20 Integrated Voltage Measurement... 15:55:29 Voltage Offset Correction: v_off_ini = 2815.044 uV, v_off_fin = 2817.257 uV 15:55:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.337 uVs 15:55:29 Integrated Voltage Measurement... 15:55:38 Voltage Offset Correction: v_off_ini = 2813.014 uV, v_off_fin = 2840.757 uV 15:55:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.026 uVs 15:55:42 I1Y Average and RMS of Measurements VT = -196.151 +- 5.973 uVs I1Y = -39.231 +- 1.195 uTm 15:55:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:50 Integrated Voltage Measurement... 15:55:59 Voltage Offset Correction: v_off_ini = 2858.839 uV, v_off_fin = 2836.861 uV 15:55:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -158.249 uVs 15:55:59 Integrated Voltage Measurement... 15:56:08 Voltage Offset Correction: v_off_ini = 2852.472 uV, v_off_fin = 2865.937 uV 15:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.010 uVs 15:56:08 Integrated Voltage Measurement... 15:56:17 Voltage Offset Correction: v_off_ini = 2851.576 uV, v_off_fin = 2841.555 uV 15:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.435 uVs 15:56:17 Integrated Voltage Measurement... 15:56:26 Voltage Offset Correction: v_off_ini = 2845.296 uV, v_off_fin = 2836.671 uV 15:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.077 uVs 15:56:26 Integrated Voltage Measurement... 15:56:35 Voltage Offset Correction: v_off_ini = 2837.512 uV, v_off_fin = 2820.042 uV 15:56:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -136.316 uVs 15:56:35 Integrated Voltage Measurement... 15:56:44 Voltage Offset Correction: v_off_ini = 2831.625 uV, v_off_fin = 2841.518 uV 15:56:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.288 uVs 15:56:46 I2X Average and RMS of Measurements VT = -138.729 +- 9.681 uVs I2X = 12.763 +- 0.890 uTm^2 15:56:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:54 Integrated Voltage Measurement... 15:57:03 Voltage Offset Correction: v_off_ini = 2828.971 uV, v_off_fin = 2853.471 uV 15:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.984 uVs 15:57:03 Integrated Voltage Measurement... 15:57:12 Voltage Offset Correction: v_off_ini = 2824.445 uV, v_off_fin = 2847.530 uV 15:57:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.052 uVs 15:57:12 Integrated Voltage Measurement... 15:57:21 Voltage Offset Correction: v_off_ini = 2844.919 uV, v_off_fin = 2871.586 uV 15:57:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.768 uVs 15:57:21 Integrated Voltage Measurement... 15:57:30 Voltage Offset Correction: v_off_ini = 2889.794 uV, v_off_fin = 2902.163 uV 15:57:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.254 uVs 15:57:30 Integrated Voltage Measurement... 15:57:39 Voltage Offset Correction: v_off_ini = 2897.829 uV, v_off_fin = 2872.455 uV 15:57:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.798 uVs 15:57:39 Integrated Voltage Measurement... 15:57:48 Voltage Offset Correction: v_off_ini = 2874.498 uV, v_off_fin = 2894.538 uV 15:57:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.064 uVs 15:57:51 I2Y Average and RMS of Measurements VT = -197.986 +- 3.714 uVs I2Y = -18.215 +- 0.342 uTm^2 15:58:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:06 Integrated Voltage Measurement... 15:58:15 Voltage Offset Correction: v_off_ini = 2849.301 uV, v_off_fin = 2863.818 uV 15:58:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -202.422 uVs 15:58:15 Integrated Voltage Measurement... 15:58:24 Voltage Offset Correction: v_off_ini = 2863.900 uV, v_off_fin = 2861.627 uV 15:58:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.185 uVs 15:58:24 Integrated Voltage Measurement... 15:58:33 Voltage Offset Correction: v_off_ini = 2848.862 uV, v_off_fin = 2873.555 uV 15:58:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -196.595 uVs 15:58:33 Integrated Voltage Measurement... 15:58:42 Voltage Offset Correction: v_off_ini = 2870.077 uV, v_off_fin = 2859.307 uV 15:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 173.577 uVs 15:58:42 Integrated Voltage Measurement... 15:58:51 Voltage Offset Correction: v_off_ini = 2882.146 uV, v_off_fin = 2874.023 uV 15:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -207.231 uVs 15:58:51 Integrated Voltage Measurement... 15:59:00 Voltage Offset Correction: v_off_ini = 2859.530 uV, v_off_fin = 2873.462 uV 15:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.471 uVs 15:59:04 I1X Average and RMS of Measurements VT = -181.247 +- 3.178 uVs I1X = 36.249 +- 0.636 uTm 15:59:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:11 Integrated Voltage Measurement... 15:59:19 Voltage Offset Correction: v_off_ini = 2852.052 uV, v_off_fin = 2847.450 uV 15:59:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -179.525 uVs 15:59:20 Integrated Voltage Measurement... 15:59:28 Voltage Offset Correction: v_off_ini = 2844.401 uV, v_off_fin = 2848.118 uV 15:59:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.144 uVs 15:59:29 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 2836.176 uV, v_off_fin = 2833.757 uV 15:59:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.960 uVs 15:59:38 Integrated Voltage Measurement... 15:59:46 Voltage Offset Correction: v_off_ini = 2857.594 uV, v_off_fin = 2866.914 uV 15:59:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 180.006 uVs 15:59:47 Integrated Voltage Measurement... 15:59:55 Voltage Offset Correction: v_off_ini = 2857.809 uV, v_off_fin = 2844.438 uV 15:59:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.334 uVs 15:59:56 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = 2865.161 uV, v_off_fin = 2841.416 uV 16:00:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.040 uVs 16:00:09 I1Y Average and RMS of Measurements VT = -186.002 +- 3.109 uVs I1Y = -37.198 +- 0.623 uTm 16:00:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:16 Integrated Voltage Measurement... 16:00:25 Voltage Offset Correction: v_off_ini = 2849.006 uV, v_off_fin = 2841.120 uV 16:00:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -138.693 uVs 16:00:25 Integrated Voltage Measurement... 16:00:34 Voltage Offset Correction: v_off_ini = 2846.702 uV, v_off_fin = 2856.124 uV 16:00:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.143 uVs 16:00:34 Integrated Voltage Measurement... 16:00:43 Voltage Offset Correction: v_off_ini = 2859.801 uV, v_off_fin = 2838.189 uV 16:00:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -140.496 uVs 16:00:44 Integrated Voltage Measurement... 16:00:52 Voltage Offset Correction: v_off_ini = 2853.118 uV, v_off_fin = 2869.578 uV 16:00:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.084 uVs 16:00:53 Integrated Voltage Measurement... 16:01:01 Voltage Offset Correction: v_off_ini = 2856.876 uV, v_off_fin = 2824.334 uV 16:01:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -163.634 uVs 16:01:02 Integrated Voltage Measurement... 16:01:11 Voltage Offset Correction: v_off_ini = 2821.649 uV, v_off_fin = 2852.751 uV 16:01:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.955 uVs 16:01:13 I2X Average and RMS of Measurements VT = -146.334 +- 10.775 uVs I2X = 13.463 +- 0.992 uTm^2 16:01:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:21 Integrated Voltage Measurement... 16:01:30 Voltage Offset Correction: v_off_ini = 2842.636 uV, v_off_fin = 2860.025 uV 16:01:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.130 uVs 16:01:30 Integrated Voltage Measurement... 16:01:39 Voltage Offset Correction: v_off_ini = 2840.046 uV, v_off_fin = 2854.418 uV 16:01:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.081 uVs 16:01:39 Integrated Voltage Measurement... 16:01:48 Voltage Offset Correction: v_off_ini = 2869.595 uV, v_off_fin = 2887.031 uV 16:01:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.011 uVs 16:01:48 Integrated Voltage Measurement... 16:01:57 Voltage Offset Correction: v_off_ini = 2897.150 uV, v_off_fin = 2887.105 uV 16:01:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.362 uVs 16:01:57 Integrated Voltage Measurement... 16:02:06 Voltage Offset Correction: v_off_ini = 2892.008 uV, v_off_fin = 2883.434 uV 16:02:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.481 uVs 16:02:06 Integrated Voltage Measurement... 16:02:15 Voltage Offset Correction: v_off_ini = 2886.843 uV, v_off_fin = 2901.470 uV 16:02:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.783 uVs 16:02:17 I2Y Average and RMS of Measurements VT = -187.141 +- 6.132 uVs I2Y = -17.217 +- 0.564 uTm^2 16:02:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:32 Integrated Voltage Measurement... 16:02:41 Voltage Offset Correction: v_off_ini = 2911.304 uV, v_off_fin = 2908.426 uV 16:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.175 uVs 16:02:41 Integrated Voltage Measurement... 16:02:50 Voltage Offset Correction: v_off_ini = 2890.493 uV, v_off_fin = 2889.431 uV 16:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.514 uVs 16:02:50 Integrated Voltage Measurement... 16:02:59 Voltage Offset Correction: v_off_ini = 2894.588 uV, v_off_fin = 2883.635 uV 16:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -197.501 uVs 16:02:59 Integrated Voltage Measurement... 16:03:08 Voltage Offset Correction: v_off_ini = 2853.046 uV, v_off_fin = 2888.447 uV 16:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.654 uVs 16:03:08 Integrated Voltage Measurement... 16:03:17 Voltage Offset Correction: v_off_ini = 2877.794 uV, v_off_fin = 2857.373 uV 16:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.557 uVs 16:03:17 Integrated Voltage Measurement... 16:03:26 Voltage Offset Correction: v_off_ini = 2861.274 uV, v_off_fin = 2849.866 uV 16:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.742 uVs 16:03:30 I1X Average and RMS of Measurements VT = -178.524 +- 3.361 uVs I1X = 35.705 +- 0.672 uTm 16:03:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:37 Integrated Voltage Measurement... 16:03:46 Voltage Offset Correction: v_off_ini = 2867.692 uV, v_off_fin = 2865.923 uV 16:03:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.837 uVs 16:03:46 Integrated Voltage Measurement... 16:03:55 Voltage Offset Correction: v_off_ini = 2861.716 uV, v_off_fin = 2892.107 uV 16:03:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.443 uVs 16:03:55 Integrated Voltage Measurement... 16:04:04 Voltage Offset Correction: v_off_ini = 2825.538 uV, v_off_fin = 2862.122 uV 16:04:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.832 uVs 16:04:04 Integrated Voltage Measurement... 16:04:13 Voltage Offset Correction: v_off_ini = 2868.946 uV, v_off_fin = 2896.092 uV 16:04:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.236 uVs 16:04:13 Integrated Voltage Measurement... 16:04:22 Voltage Offset Correction: v_off_ini = 2900.294 uV, v_off_fin = 2874.744 uV 16:04:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.789 uVs 16:04:22 Integrated Voltage Measurement... 16:04:31 Voltage Offset Correction: v_off_ini = 2900.498 uV, v_off_fin = 2918.418 uV 16:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.081 uVs 16:04:35 I1Y Average and RMS of Measurements VT = -177.536 +- 4.575 uVs I1Y = -35.506 +- 0.914 uTm 16:04:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:43 Integrated Voltage Measurement... 16:04:52 Voltage Offset Correction: v_off_ini = 2892.879 uV, v_off_fin = 2896.931 uV 16:04:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -157.084 uVs 16:04:52 Integrated Voltage Measurement... 16:05:01 Voltage Offset Correction: v_off_ini = 2899.586 uV, v_off_fin = 2893.997 uV 16:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.798 uVs 16:05:01 Integrated Voltage Measurement... 16:05:10 Voltage Offset Correction: v_off_ini = 2887.753 uV, v_off_fin = 2877.712 uV 16:05:10 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -132.245 uVs 16:05:10 Integrated Voltage Measurement... 16:05:19 Voltage Offset Correction: v_off_ini = 2862.701 uV, v_off_fin = 2872.015 uV 16:05:19 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 171.385 uVs 16:05:19 Integrated Voltage Measurement... 16:05:28 Voltage Offset Correction: v_off_ini = 2878.420 uV, v_off_fin = 2884.646 uV 16:05:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -135.206 uVs 16:05:28 Integrated Voltage Measurement... 16:05:37 Voltage Offset Correction: v_off_ini = 2913.175 uV, v_off_fin = 2909.554 uV 16:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.031 uVs 16:05:39 I2X Average and RMS of Measurements VT = -150.292 +- 4.152 uVs I2X = 13.828 +- 0.382 uTm^2 16:05:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:47 Integrated Voltage Measurement... 16:05:56 Voltage Offset Correction: v_off_ini = 2902.645 uV, v_off_fin = 2889.268 uV 16:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.581 uVs 16:05:56 Integrated Voltage Measurement... 16:06:05 Voltage Offset Correction: v_off_ini = 2888.813 uV, v_off_fin = 2895.587 uV 16:06:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.139 uVs 16:06:05 Integrated Voltage Measurement... 16:06:14 Voltage Offset Correction: v_off_ini = 2883.797 uV, v_off_fin = 2894.309 uV 16:06:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.526 uVs 16:06:14 Integrated Voltage Measurement... 16:06:23 Voltage Offset Correction: v_off_ini = 2924.918 uV, v_off_fin = 2893.679 uV 16:06:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.366 uVs 16:06:23 Integrated Voltage Measurement... 16:06:32 Voltage Offset Correction: v_off_ini = 2893.020 uV, v_off_fin = 2886.788 uV 16:06:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.644 uVs 16:06:32 Integrated Voltage Measurement... 16:06:41 Voltage Offset Correction: v_off_ini = 2894.806 uV, v_off_fin = 2882.823 uV 16:06:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 168.365 uVs 16:06:44 I2Y Average and RMS of Measurements VT = -169.270 +- 3.748 uVs I2Y = -15.573 +- 0.345 uTm^2 16:06:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:59 Integrated Voltage Measurement... 16:07:08 Voltage Offset Correction: v_off_ini = 2928.489 uV, v_off_fin = 2906.781 uV 16:07:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.728 uVs 16:07:08 Integrated Voltage Measurement... 16:07:17 Voltage Offset Correction: v_off_ini = 2916.734 uV, v_off_fin = 2906.941 uV 16:07:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 196.966 uVs 16:07:17 Integrated Voltage Measurement... 16:07:26 Voltage Offset Correction: v_off_ini = 2885.526 uV, v_off_fin = 2887.742 uV 16:07:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -164.142 uVs 16:07:26 Integrated Voltage Measurement... 16:07:35 Voltage Offset Correction: v_off_ini = 2922.510 uV, v_off_fin = 2874.183 uV 16:07:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 223.357 uVs 16:07:35 Integrated Voltage Measurement... 16:07:44 Voltage Offset Correction: v_off_ini = 2903.998 uV, v_off_fin = 2915.798 uV 16:07:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -190.520 uVs 16:07:44 Integrated Voltage Measurement... 16:07:53 Voltage Offset Correction: v_off_ini = 2913.676 uV, v_off_fin = 2909.315 uV 16:07:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 185.673 uVs 16:07:57 I1X Average and RMS of Measurements VT = -184.231 +- 9.741 uVs I1X = 36.846 +- 1.948 uTm 16:07:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:04 Integrated Voltage Measurement... 16:08:12 Voltage Offset Correction: v_off_ini = 2897.995 uV, v_off_fin = 2883.722 uV 16:08:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -174.418 uVs 16:08:13 Integrated Voltage Measurement... 16:08:21 Voltage Offset Correction: v_off_ini = 2893.031 uV, v_off_fin = 2907.600 uV 16:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 161.786 uVs 16:08:22 Integrated Voltage Measurement... 16:08:30 Voltage Offset Correction: v_off_ini = 2890.135 uV, v_off_fin = 2867.945 uV 16:08:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.878 uVs 16:08:31 Integrated Voltage Measurement... 16:08:39 Voltage Offset Correction: v_off_ini = 2890.286 uV, v_off_fin = 2896.434 uV 16:08:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 155.321 uVs 16:08:39 Integrated Voltage Measurement... 16:08:48 Voltage Offset Correction: v_off_ini = 2893.534 uV, v_off_fin = 2896.536 uV 16:08:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.251 uVs 16:08:48 Integrated Voltage Measurement... 16:08:57 Voltage Offset Correction: v_off_ini = 2907.860 uV, v_off_fin = 2921.405 uV 16:08:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 169.573 uVs 16:09:02 I1Y Average and RMS of Measurements VT = -175.038 +- 7.786 uVs I1Y = -35.005 +- 1.556 uTm 16:09:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:09 Integrated Voltage Measurement... 16:09:18 Voltage Offset Correction: v_off_ini = 2903.932 uV, v_off_fin = 2889.675 uV 16:09:18 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -139.044 uVs 16:09:18 Integrated Voltage Measurement... 16:09:27 Voltage Offset Correction: v_off_ini = 2893.895 uV, v_off_fin = 2914.006 uV 16:09:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.762 uVs 16:09:27 Integrated Voltage Measurement... 16:09:36 Voltage Offset Correction: v_off_ini = 2923.664 uV, v_off_fin = 2905.746 uV 16:09:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.996 uVs 16:09:36 Integrated Voltage Measurement... 16:09:45 Voltage Offset Correction: v_off_ini = 2884.945 uV, v_off_fin = 2892.346 uV 16:09:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 175.169 uVs 16:09:45 Integrated Voltage Measurement... 16:09:54 Voltage Offset Correction: v_off_ini = 2894.658 uV, v_off_fin = 2883.332 uV 16:09:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.120 uVs 16:09:54 Integrated Voltage Measurement... 16:10:03 Voltage Offset Correction: v_off_ini = 2915.342 uV, v_off_fin = 2938.197 uV 16:10:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 176.994 uVs 16:10:06 I2X Average and RMS of Measurements VT = -151.014 +- 2.562 uVs I2X = 13.893 +- 0.236 uTm^2 16:10:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:13 Integrated Voltage Measurement... 16:10:22 Voltage Offset Correction: v_off_ini = 2913.822 uV, v_off_fin = 2927.853 uV 16:10:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.408 uVs 16:10:22 Integrated Voltage Measurement... 16:10:31 Voltage Offset Correction: v_off_ini = 2937.597 uV, v_off_fin = 2950.726 uV 16:10:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 136.006 uVs 16:10:31 Integrated Voltage Measurement... 16:10:40 Voltage Offset Correction: v_off_ini = 2931.808 uV, v_off_fin = 2930.727 uV 16:10:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.431 uVs 16:10:40 Integrated Voltage Measurement... 16:10:49 Voltage Offset Correction: v_off_ini = 2934.161 uV, v_off_fin = 2926.655 uV 16:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.675 uVs 16:10:49 Integrated Voltage Measurement... 16:10:58 Voltage Offset Correction: v_off_ini = 2909.469 uV, v_off_fin = 2922.744 uV 16:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.926 uVs 16:10:58 Integrated Voltage Measurement... 16:11:07 Voltage Offset Correction: v_off_ini = 2942.782 uV, v_off_fin = 2921.307 uV 16:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.987 uVs 16:11:10 I2Y Average and RMS of Measurements VT = -167.239 +- 7.106 uVs I2Y = -15.386 +- 0.654 uTm^2 16:11:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:25 Integrated Voltage Measurement... 16:11:34 Voltage Offset Correction: v_off_ini = 2919.144 uV, v_off_fin = 2929.478 uV 16:11:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -155.845 uVs 16:11:34 Integrated Voltage Measurement... 16:11:43 Voltage Offset Correction: v_off_ini = 2941.321 uV, v_off_fin = 2917.852 uV 16:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 193.419 uVs 16:11:43 Integrated Voltage Measurement... 16:11:52 Voltage Offset Correction: v_off_ini = 2928.352 uV, v_off_fin = 2927.805 uV 16:11:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -179.086 uVs 16:11:52 Integrated Voltage Measurement... 16:12:01 Voltage Offset Correction: v_off_ini = 2943.338 uV, v_off_fin = 2939.470 uV 16:12:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 186.800 uVs 16:12:01 Integrated Voltage Measurement... 16:12:10 Voltage Offset Correction: v_off_ini = 2928.052 uV, v_off_fin = 2902.904 uV 16:12:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.528 uVs 16:12:10 Integrated Voltage Measurement... 16:12:19 Voltage Offset Correction: v_off_ini = 2901.365 uV, v_off_fin = 2888.210 uV 16:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 188.014 uVs 16:12:23 I1X Average and RMS of Measurements VT = -183.782 +- 7.836 uVs I1X = 36.759 +- 1.566 uTm 16:12:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:30 Integrated Voltage Measurement... 16:12:39 Voltage Offset Correction: v_off_ini = 2923.651 uV, v_off_fin = 2909.838 uV 16:12:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.753 uVs 16:12:39 Integrated Voltage Measurement... 16:12:48 Voltage Offset Correction: v_off_ini = 2908.600 uV, v_off_fin = 2914.928 uV 16:12:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.073 uVs 16:12:48 Integrated Voltage Measurement... 16:12:57 Voltage Offset Correction: v_off_ini = 2914.999 uV, v_off_fin = 2910.480 uV 16:12:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.429 uVs 16:12:57 Integrated Voltage Measurement... 16:13:06 Voltage Offset Correction: v_off_ini = 2915.091 uV, v_off_fin = 2926.273 uV 16:13:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 150.732 uVs 16:13:06 Integrated Voltage Measurement... 16:13:14 Voltage Offset Correction: v_off_ini = 2902.084 uV, v_off_fin = 2913.111 uV 16:13:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -200.547 uVs 16:13:15 Integrated Voltage Measurement... 16:13:23 Voltage Offset Correction: v_off_ini = 2936.700 uV, v_off_fin = 2945.299 uV 16:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.459 uVs 16:13:28 I1Y Average and RMS of Measurements VT = -180.499 +- 6.055 uVs I1Y = -36.099 +- 1.212 uTm 16:13:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:35 Integrated Voltage Measurement... 16:13:44 Voltage Offset Correction: v_off_ini = 2913.915 uV, v_off_fin = 2920.135 uV 16:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.058 uVs 16:13:44 Integrated Voltage Measurement... 16:13:53 Voltage Offset Correction: v_off_ini = 2940.539 uV, v_off_fin = 2964.614 uV 16:13:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.524 uVs 16:13:53 Integrated Voltage Measurement... 16:14:02 Voltage Offset Correction: v_off_ini = 2961.593 uV, v_off_fin = 2953.600 uV 16:14:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.970 uVs 16:14:02 Integrated Voltage Measurement... 16:14:11 Voltage Offset Correction: v_off_ini = 2953.284 uV, v_off_fin = 2996.594 uV 16:14:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.957 uVs 16:14:11 Integrated Voltage Measurement... 16:14:20 Voltage Offset Correction: v_off_ini = 2988.692 uV, v_off_fin = 2957.807 uV 16:14:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -158.634 uVs 16:14:20 Integrated Voltage Measurement... 16:14:29 Voltage Offset Correction: v_off_ini = 2965.844 uV, v_off_fin = 2958.961 uV 16:14:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.807 uVs 16:14:32 I2X Average and RMS of Measurements VT = -152.325 +- 11.053 uVs I2X = 14.014 +- 1.017 uTm^2 16:14:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:39 Integrated Voltage Measurement... 16:14:48 Voltage Offset Correction: v_off_ini = 2965.626 uV, v_off_fin = 2935.412 uV 16:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.288 uVs 16:14:48 Integrated Voltage Measurement... 16:14:57 Voltage Offset Correction: v_off_ini = 2974.624 uV, v_off_fin = 2980.189 uV 16:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.858 uVs 16:14:58 Integrated Voltage Measurement... 16:15:06 Voltage Offset Correction: v_off_ini = 2970.922 uV, v_off_fin = 2978.210 uV 16:15:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.103 uVs 16:15:07 Integrated Voltage Measurement... 16:15:15 Voltage Offset Correction: v_off_ini = 2974.227 uV, v_off_fin = 2967.309 uV 16:15:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.327 uVs 16:15:16 Integrated Voltage Measurement... 16:15:25 Voltage Offset Correction: v_off_ini = 2981.520 uV, v_off_fin = 2982.127 uV 16:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.647 uVs 16:15:25 Integrated Voltage Measurement... 16:15:34 Voltage Offset Correction: v_off_ini = 3022.077 uV, v_off_fin = 3003.723 uV 16:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.256 uVs 16:15:36 I2Y Average and RMS of Measurements VT = -163.580 +- 5.920 uVs I2Y = -15.049 +- 0.545 uTm^2 16:15:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:51 Integrated Voltage Measurement... 16:16:00 Voltage Offset Correction: v_off_ini = 2970.275 uV, v_off_fin = 2966.322 uV 16:16:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -185.735 uVs 16:16:00 Integrated Voltage Measurement... 16:16:09 Voltage Offset Correction: v_off_ini = 2972.417 uV, v_off_fin = 2984.461 uV 16:16:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 178.531 uVs 16:16:09 Integrated Voltage Measurement... 16:16:18 Voltage Offset Correction: v_off_ini = 2982.120 uV, v_off_fin = 2984.660 uV 16:16:18 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -193.656 uVs 16:16:18 Integrated Voltage Measurement... 16:16:27 Voltage Offset Correction: v_off_ini = 2999.600 uV, v_off_fin = 2988.617 uV 16:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 181.866 uVs 16:16:27 Integrated Voltage Measurement... 16:16:36 Voltage Offset Correction: v_off_ini = 2968.295 uV, v_off_fin = 2942.090 uV 16:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -162.370 uVs 16:16:36 Integrated Voltage Measurement... 16:16:45 Voltage Offset Correction: v_off_ini = 2962.768 uV, v_off_fin = 2966.783 uV 16:16:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.070 uVs 16:16:49 I1X Average and RMS of Measurements VT = -179.038 +- 8.667 uVs I1X = 35.809 +- 1.735 uTm 16:16:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:56 Integrated Voltage Measurement... 16:17:05 Voltage Offset Correction: v_off_ini = 2971.972 uV, v_off_fin = 2946.317 uV 16:17:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.354 uVs 16:17:05 Integrated Voltage Measurement... 16:17:14 Voltage Offset Correction: v_off_ini = 2953.832 uV, v_off_fin = 2958.583 uV 16:17:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 179.563 uVs 16:17:14 Integrated Voltage Measurement... 16:17:23 Voltage Offset Correction: v_off_ini = 2963.272 uV, v_off_fin = 2953.778 uV 16:17:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.262 uVs 16:17:23 Integrated Voltage Measurement... 16:17:32 Voltage Offset Correction: v_off_ini = 2939.229 uV, v_off_fin = 2972.159 uV 16:17:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.409 uVs 16:17:32 Integrated Voltage Measurement... 16:17:41 Voltage Offset Correction: v_off_ini = 2960.533 uV, v_off_fin = 2960.384 uV 16:17:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.660 uVs 16:17:41 Integrated Voltage Measurement... 16:17:50 Voltage Offset Correction: v_off_ini = 3002.766 uV, v_off_fin = 3005.868 uV 16:17:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.547 uVs 16:17:54 I1Y Average and RMS of Measurements VT = -177.799 +- 4.472 uVs I1Y = -35.559 +- 0.895 uTm 16:17:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:02 Integrated Voltage Measurement... 16:18:11 Voltage Offset Correction: v_off_ini = 3006.048 uV, v_off_fin = 2991.941 uV 16:18:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.839 uVs 16:18:11 Integrated Voltage Measurement... 16:18:20 Voltage Offset Correction: v_off_ini = 3011.268 uV, v_off_fin = 3047.269 uV 16:18:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.527 uVs 16:18:20 Integrated Voltage Measurement... 16:18:29 Voltage Offset Correction: v_off_ini = 3023.801 uV, v_off_fin = 3002.027 uV 16:18:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -136.907 uVs 16:18:29 Integrated Voltage Measurement... 16:18:38 Voltage Offset Correction: v_off_ini = 3002.631 uV, v_off_fin = 3018.477 uV 16:18:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.793 uVs 16:18:38 Integrated Voltage Measurement... 16:18:47 Voltage Offset Correction: v_off_ini = 3027.840 uV, v_off_fin = 2995.016 uV 16:18:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.804 uVs 16:18:47 Integrated Voltage Measurement... 16:18:56 Voltage Offset Correction: v_off_ini = 2998.461 uV, v_off_fin = 2999.141 uV 16:18:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.966 uVs 16:18:58 I2X Average and RMS of Measurements VT = -131.639 +- 12.473 uVs I2X = 12.111 +- 1.147 uTm^2 16:19:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:06 Integrated Voltage Measurement... 16:19:15 Voltage Offset Correction: v_off_ini = 3009.594 uV, v_off_fin = 3002.752 uV 16:19:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.278 uVs 16:19:15 Integrated Voltage Measurement... 16:19:24 Voltage Offset Correction: v_off_ini = 3018.501 uV, v_off_fin = 3013.185 uV 16:19:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.596 uVs 16:19:24 Integrated Voltage Measurement... 16:19:33 Voltage Offset Correction: v_off_ini = 3021.159 uV, v_off_fin = 3026.992 uV 16:19:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.474 uVs 16:19:33 Integrated Voltage Measurement... 16:19:42 Voltage Offset Correction: v_off_ini = 3008.568 uV, v_off_fin = 3041.390 uV 16:19:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.953 uVs 16:19:42 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = 3029.474 uV, v_off_fin = 3023.478 uV 16:19:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.451 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = 3031.155 uV, v_off_fin = 3016.665 uV 16:20:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.477 uVs 16:20:02 I2Y Average and RMS of Measurements VT = -171.038 +- 10.276 uVs I2Y = -15.736 +- 0.945 uTm^2 16:20:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:19 Integrated Voltage Measurement... 16:20:28 Voltage Offset Correction: v_off_ini = 3031.230 uV, v_off_fin = 3009.192 uV 16:20:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -195.018 uVs 16:20:28 Integrated Voltage Measurement... 16:20:37 Voltage Offset Correction: v_off_ini = 3028.201 uV, v_off_fin = 3029.958 uV 16:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 177.612 uVs 16:20:37 Integrated Voltage Measurement... 16:20:46 Voltage Offset Correction: v_off_ini = 3032.145 uV, v_off_fin = 3032.088 uV 16:20:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -170.903 uVs 16:20:46 Integrated Voltage Measurement... 16:20:55 Voltage Offset Correction: v_off_ini = 3057.651 uV, v_off_fin = 3049.050 uV 16:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 181.579 uVs 16:20:55 Integrated Voltage Measurement... 16:21:04 Voltage Offset Correction: v_off_ini = 3037.601 uV, v_off_fin = 3028.029 uV 16:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.561 uVs 16:21:04 Integrated Voltage Measurement... 16:21:13 Voltage Offset Correction: v_off_ini = 3029.877 uV, v_off_fin = 3033.702 uV 16:21:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.179 uVs 16:21:17 I1X Average and RMS of Measurements VT = -175.309 +- 9.390 uVs I1X = 35.062 +- 1.879 uTm 16:21:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:24 Integrated Voltage Measurement... 16:21:33 Voltage Offset Correction: v_off_ini = 3021.730 uV, v_off_fin = 3026.711 uV 16:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -154.253 uVs 16:21:33 Integrated Voltage Measurement... 16:21:42 Voltage Offset Correction: v_off_ini = 3030.467 uV, v_off_fin = 3028.276 uV 16:21:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.639 uVs 16:21:42 Integrated Voltage Measurement... 16:21:50 Voltage Offset Correction: v_off_ini = 3059.336 uV, v_off_fin = 3039.118 uV 16:21:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.905 uVs 16:21:51 Integrated Voltage Measurement... 16:21:59 Voltage Offset Correction: v_off_ini = 3052.719 uV, v_off_fin = 3061.059 uV 16:21:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.624 uVs 16:21:59 Integrated Voltage Measurement... 16:22:08 Voltage Offset Correction: v_off_ini = 3023.387 uV, v_off_fin = 3028.219 uV 16:22:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.529 uVs 16:22:08 Integrated Voltage Measurement... 16:22:17 Voltage Offset Correction: v_off_ini = 3042.810 uV, v_off_fin = 3040.047 uV 16:22:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.841 uVs 16:22:22 I1Y Average and RMS of Measurements VT = -164.965 +- 8.389 uVs I1Y = -32.994 +- 1.677 uTm 16:22:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:29 Integrated Voltage Measurement... 16:22:38 Voltage Offset Correction: v_off_ini = 3021.476 uV, v_off_fin = 3021.366 uV 16:22:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -170.979 uVs 16:22:38 Integrated Voltage Measurement... 16:22:47 Voltage Offset Correction: v_off_ini = 3017.464 uV, v_off_fin = 3009.894 uV 16:22:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.492 uVs 16:22:47 Integrated Voltage Measurement... 16:22:56 Voltage Offset Correction: v_off_ini = 3004.414 uV, v_off_fin = 2994.868 uV 16:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -120.864 uVs 16:22:56 Integrated Voltage Measurement... 16:23:05 Voltage Offset Correction: v_off_ini = 3017.284 uV, v_off_fin = 3020.902 uV 16:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.949 uVs 16:23:05 Integrated Voltage Measurement... 16:23:14 Voltage Offset Correction: v_off_ini = 2993.892 uV, v_off_fin = 2994.025 uV 16:23:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.327 uVs 16:23:14 Integrated Voltage Measurement... 16:23:23 Voltage Offset Correction: v_off_ini = 3009.643 uV, v_off_fin = 3026.464 uV 16:23:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.452 uVs 16:23:26 I2X Average and RMS of Measurements VT = -144.844 +- 16.097 uVs I2X = 13.325 +- 1.481 uTm^2 16:23:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:33 Integrated Voltage Measurement... 16:23:42 Voltage Offset Correction: v_off_ini = 3015.718 uV, v_off_fin = 3028.865 uV 16:23:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.914 uVs 16:23:42 Integrated Voltage Measurement... 16:23:51 Voltage Offset Correction: v_off_ini = 3036.862 uV, v_off_fin = 3050.225 uV 16:23:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.060 uVs 16:23:52 Integrated Voltage Measurement... 16:24:00 Voltage Offset Correction: v_off_ini = 3053.480 uV, v_off_fin = 3040.393 uV 16:24:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.557 uVs 16:24:01 Integrated Voltage Measurement... 16:24:10 Voltage Offset Correction: v_off_ini = 3055.865 uV, v_off_fin = 3056.326 uV 16:24:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 142.124 uVs 16:24:10 Integrated Voltage Measurement... 16:24:19 Voltage Offset Correction: v_off_ini = 3048.616 uV, v_off_fin = 3046.322 uV 16:24:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.737 uVs 16:24:19 Integrated Voltage Measurement... 16:24:28 Voltage Offset Correction: v_off_ini = 3053.025 uV, v_off_fin = 3038.061 uV 16:24:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.641 uVs 16:24:30 I2Y Average and RMS of Measurements VT = -161.506 +- 3.768 uVs I2Y = -14.859 +- 0.346 uTm^2 16:24:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:46 Integrated Voltage Measurement... 16:24:55 Voltage Offset Correction: v_off_ini = 3058.849 uV, v_off_fin = 3065.977 uV 16:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.606 uVs 16:24:55 Integrated Voltage Measurement... 16:25:04 Voltage Offset Correction: v_off_ini = 3045.819 uV, v_off_fin = 3072.632 uV 16:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 175.427 uVs 16:25:04 Integrated Voltage Measurement... 16:25:13 Voltage Offset Correction: v_off_ini = 3049.712 uV, v_off_fin = 3049.463 uV 16:25:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -179.836 uVs 16:25:13 Integrated Voltage Measurement... 16:25:22 Voltage Offset Correction: v_off_ini = 3065.483 uV, v_off_fin = 3068.415 uV 16:25:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 154.991 uVs 16:25:22 Integrated Voltage Measurement... 16:25:31 Voltage Offset Correction: v_off_ini = 3046.178 uV, v_off_fin = 3045.638 uV 16:25:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -181.123 uVs 16:25:31 Integrated Voltage Measurement... 16:25:40 Voltage Offset Correction: v_off_ini = 3059.368 uV, v_off_fin = 3055.286 uV 16:25:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.190 uVs 16:25:44 I1X Average and RMS of Measurements VT = -166.195 +- 1.897 uVs I1X = 33.241 +- 0.381 uTm 16:25:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:51 Integrated Voltage Measurement... 16:26:00 Voltage Offset Correction: v_off_ini = 3057.599 uV, v_off_fin = 3026.123 uV 16:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -175.837 uVs 16:26:00 Integrated Voltage Measurement... 16:26:09 Voltage Offset Correction: v_off_ini = 3032.640 uV, v_off_fin = 3035.806 uV 16:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.922 uVs 16:26:09 Integrated Voltage Measurement... 16:26:18 Voltage Offset Correction: v_off_ini = 3050.641 uV, v_off_fin = 3028.355 uV 16:26:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.015 uVs 16:26:18 Integrated Voltage Measurement... 16:26:27 Voltage Offset Correction: v_off_ini = 3029.956 uV, v_off_fin = 3029.977 uV 16:26:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.653 uVs 16:26:27 Integrated Voltage Measurement... 16:26:36 Voltage Offset Correction: v_off_ini = 3025.105 uV, v_off_fin = 3014.882 uV 16:26:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.525 uVs 16:26:36 Integrated Voltage Measurement... 16:26:45 Voltage Offset Correction: v_off_ini = 3041.494 uV, v_off_fin = 3053.134 uV 16:26:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.340 uVs 16:26:49 I1Y Average and RMS of Measurements VT = -175.382 +- 10.847 uVs I1Y = -35.076 +- 2.169 uTm 16:26:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:57 Integrated Voltage Measurement... 16:27:06 Voltage Offset Correction: v_off_ini = 3011.997 uV, v_off_fin = 3010.956 uV 16:27:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.599 uVs 16:27:06 Integrated Voltage Measurement... 16:27:15 Voltage Offset Correction: v_off_ini = 3015.991 uV, v_off_fin = 3020.570 uV 16:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.171 uVs 16:27:15 Integrated Voltage Measurement... 16:27:24 Voltage Offset Correction: v_off_ini = 3017.058 uV, v_off_fin = 3016.692 uV 16:27:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.848 uVs 16:27:24 Integrated Voltage Measurement... 16:27:33 Voltage Offset Correction: v_off_ini = 3013.607 uV, v_off_fin = 3051.965 uV 16:27:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.739 uVs 16:27:33 Integrated Voltage Measurement... 16:27:42 Voltage Offset Correction: v_off_ini = 3053.219 uV, v_off_fin = 3015.937 uV 16:27:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.083 uVs 16:27:42 Integrated Voltage Measurement... 16:27:51 Voltage Offset Correction: v_off_ini = 3028.707 uV, v_off_fin = 3063.286 uV 16:27:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.718 uVs 16:27:53 I2X Average and RMS of Measurements VT = -121.860 +- 5.335 uVs I2X = 11.211 +- 0.491 uTm^2 16:27:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:28:01 Integrated Voltage Measurement... 16:28:10 Voltage Offset Correction: v_off_ini = 3056.012 uV, v_off_fin = 3059.865 uV 16:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.617 uVs 16:28:10 Integrated Voltage Measurement... 16:28:19 Voltage Offset Correction: v_off_ini = 3061.071 uV, v_off_fin = 3071.370 uV 16:28:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.618 uVs 16:28:19 Integrated Voltage Measurement... 16:28:28 Voltage Offset Correction: v_off_ini = 3067.316 uV, v_off_fin = 3036.927 uV 16:28:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.558 uVs 16:28:28 Integrated Voltage Measurement... 16:28:37 Voltage Offset Correction: v_off_ini = 3019.838 uV, v_off_fin = 3019.082 uV 16:28:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.053 uVs 16:28:37 Integrated Voltage Measurement... 16:28:46 Voltage Offset Correction: v_off_ini = 3026.798 uV, v_off_fin = 3036.479 uV 16:28:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.883 uVs 16:28:46 Integrated Voltage Measurement... 16:28:55 Voltage Offset Correction: v_off_ini = 3031.502 uV, v_off_fin = 3010.095 uV 16:28:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 151.400 uVs 16:28:58 I2Y Average and RMS of Measurements VT = -166.355 +- 7.010 uVs I2Y = -15.305 +- 0.645 uTm^2 16:29:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:16 Integrated Voltage Measurement... 16:29:25 Voltage Offset Correction: v_off_ini = 3017.402 uV, v_off_fin = 2998.397 uV 16:29:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -131.321 uVs 16:29:25 Integrated Voltage Measurement... 16:29:34 Voltage Offset Correction: v_off_ini = 3048.328 uV, v_off_fin = 3009.562 uV 16:29:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.929 uVs 16:29:34 Integrated Voltage Measurement... 16:29:43 Voltage Offset Correction: v_off_ini = 2997.027 uV, v_off_fin = 2987.237 uV 16:29:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.231 uVs 16:29:43 Integrated Voltage Measurement... 16:29:52 Voltage Offset Correction: v_off_ini = 2999.652 uV, v_off_fin = 2996.473 uV 16:29:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.236 uVs 16:29:52 Integrated Voltage Measurement... 16:30:01 Voltage Offset Correction: v_off_ini = 3018.483 uV, v_off_fin = 3010.875 uV 16:30:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.469 uVs 16:30:01 Integrated Voltage Measurement... 16:30:10 Voltage Offset Correction: v_off_ini = 3022.895 uV, v_off_fin = 2994.604 uV 16:30:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.886 uVs 16:30:14 I1X Average and RMS of Measurements VT = -127.179 +- 6.863 uVs I1X = 25.438 +- 1.371 uTm 16:30:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:21 Integrated Voltage Measurement... 16:30:30 Voltage Offset Correction: v_off_ini = 2989.021 uV, v_off_fin = 2986.375 uV 16:30:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.441 uVs 16:30:30 Integrated Voltage Measurement... 16:30:39 Voltage Offset Correction: v_off_ini = 2991.441 uV, v_off_fin = 2984.904 uV 16:30:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.431 uVs 16:30:39 Integrated Voltage Measurement... 16:30:48 Voltage Offset Correction: v_off_ini = 2970.714 uV, v_off_fin = 2979.955 uV 16:30:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.466 uVs 16:30:48 Integrated Voltage Measurement... 16:30:57 Voltage Offset Correction: v_off_ini = 3000.843 uV, v_off_fin = 3013.299 uV 16:30:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.879 uVs 16:30:57 Integrated Voltage Measurement... 16:31:06 Voltage Offset Correction: v_off_ini = 2991.018 uV, v_off_fin = 2980.944 uV 16:31:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.919 uVs 16:31:06 Integrated Voltage Measurement... 16:31:15 Voltage Offset Correction: v_off_ini = 2996.561 uV, v_off_fin = 2994.282 uV 16:31:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.606 uVs 16:31:19 I1Y Average and RMS of Measurements VT = -170.124 +- 1.675 uVs I1Y = -34.025 +- 0.335 uTm 16:31:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:27 Integrated Voltage Measurement... 16:31:36 Voltage Offset Correction: v_off_ini = 2974.972 uV, v_off_fin = 2985.974 uV 16:31:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -64.610 uVs 16:31:36 Integrated Voltage Measurement... 16:31:45 Voltage Offset Correction: v_off_ini = 2996.526 uV, v_off_fin = 2994.379 uV 16:31:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.236 uVs 16:31:45 Integrated Voltage Measurement... 16:31:54 Voltage Offset Correction: v_off_ini = 2977.100 uV, v_off_fin = 2964.036 uV 16:31:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.715 uVs 16:31:54 Integrated Voltage Measurement... 16:32:03 Voltage Offset Correction: v_off_ini = 2991.352 uV, v_off_fin = 2985.309 uV 16:32:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.883 uVs 16:32:03 Integrated Voltage Measurement... 16:32:12 Voltage Offset Correction: v_off_ini = 2984.457 uV, v_off_fin = 2978.109 uV 16:32:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -121.790 uVs 16:32:12 Integrated Voltage Measurement... 16:32:21 Voltage Offset Correction: v_off_ini = 2985.880 uV, v_off_fin = 2994.789 uV 16:32:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 121.057 uVs 16:32:23 I2X Average and RMS of Measurements VT = -112.215 +- 11.553 uVs I2X = 10.324 +- 1.063 uTm^2 16:32:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 2991.917 uV, v_off_fin = 2983.022 uV 16:32:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.174 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 2992.163 uV, v_off_fin = 2994.503 uV 16:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 111.827 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 3040.869 uV, v_off_fin = 3023.865 uV 16:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.689 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 3042.180 uV, v_off_fin = 3045.292 uV 16:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.069 uVs 16:33:07 Integrated Voltage Measurement... 16:33:16 Voltage Offset Correction: v_off_ini = 3033.532 uV, v_off_fin = 3038.693 uV 16:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -161.532 uVs 16:33:16 Integrated Voltage Measurement... 16:33:25 Voltage Offset Correction: v_off_ini = 3036.985 uV, v_off_fin = 3018.686 uV 16:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.894 uVs 16:33:27 I2Y Average and RMS of Measurements VT = -159.197 +- 18.490 uVs I2Y = -14.646 +- 1.701 uTm^2 16:33:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:46 Integrated Voltage Measurement... 16:33:55 Voltage Offset Correction: v_off_ini = 3029.283 uV, v_off_fin = 3034.821 uV 16:33:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -130.183 uVs 16:33:55 Integrated Voltage Measurement... 16:34:04 Voltage Offset Correction: v_off_ini = 3035.664 uV, v_off_fin = 3053.078 uV 16:34:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.536 uVs 16:34:04 Integrated Voltage Measurement... 16:34:13 Voltage Offset Correction: v_off_ini = 3031.774 uV, v_off_fin = 3045.664 uV 16:34:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.333 uVs 16:34:13 Integrated Voltage Measurement... 16:34:22 Voltage Offset Correction: v_off_ini = 3064.989 uV, v_off_fin = 3049.777 uV 16:34:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.025 uVs 16:34:22 Integrated Voltage Measurement... 16:34:31 Voltage Offset Correction: v_off_ini = 3052.986 uV, v_off_fin = 3049.599 uV 16:34:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.872 uVs 16:34:31 Integrated Voltage Measurement... 16:34:40 Voltage Offset Correction: v_off_ini = 3055.892 uV, v_off_fin = 3054.184 uV 16:34:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.786 uVs 16:34:44 I1X Average and RMS of Measurements VT = -122.456 +- 4.969 uVs I1X = 24.493 +- 0.994 uTm 16:34:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:51 Integrated Voltage Measurement... 16:35:00 Voltage Offset Correction: v_off_ini = 3027.851 uV, v_off_fin = 3036.505 uV 16:35:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -199.978 uVs 16:35:00 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 3027.909 uV, v_off_fin = 3042.462 uV 16:35:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.281 uVs 16:35:09 Integrated Voltage Measurement... 16:35:18 Voltage Offset Correction: v_off_ini = 3015.089 uV, v_off_fin = 3008.294 uV 16:35:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.380 uVs 16:35:18 Integrated Voltage Measurement... 16:35:27 Voltage Offset Correction: v_off_ini = 3041.644 uV, v_off_fin = 3053.349 uV 16:35:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.240 uVs 16:35:27 Integrated Voltage Measurement... 16:35:36 Voltage Offset Correction: v_off_ini = 3051.116 uV, v_off_fin = 3036.608 uV 16:35:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.203 uVs 16:35:36 Integrated Voltage Measurement... 16:35:45 Voltage Offset Correction: v_off_ini = 3025.180 uV, v_off_fin = 3036.954 uV 16:35:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.690 uVs 16:35:49 I1Y Average and RMS of Measurements VT = -179.462 +- 5.774 uVs I1Y = -35.893 +- 1.155 uTm 16:35:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:57 Integrated Voltage Measurement... 16:36:06 Voltage Offset Correction: v_off_ini = 3021.302 uV, v_off_fin = 3005.564 uV 16:36:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.381 uVs 16:36:06 Integrated Voltage Measurement... 16:36:15 Voltage Offset Correction: v_off_ini = 3052.204 uV, v_off_fin = 3041.419 uV 16:36:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.348 uVs 16:36:15 Integrated Voltage Measurement... 16:36:24 Voltage Offset Correction: v_off_ini = 3026.434 uV, v_off_fin = 3007.745 uV 16:36:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.194 uVs 16:36:24 Integrated Voltage Measurement... 16:36:33 Voltage Offset Correction: v_off_ini = 3034.817 uV, v_off_fin = 3017.707 uV 16:36:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.763 uVs 16:36:33 Integrated Voltage Measurement... 16:36:42 Voltage Offset Correction: v_off_ini = 3010.133 uV, v_off_fin = 2991.759 uV 16:36:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -152.427 uVs 16:36:42 Integrated Voltage Measurement... 16:36:51 Voltage Offset Correction: v_off_ini = 3038.235 uV, v_off_fin = 3017.334 uV 16:36:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.580 uVs 16:36:53 I2X Average and RMS of Measurements VT = -115.782 +- 8.106 uVs I2X = 10.652 +- 0.746 uTm^2 16:36:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:01 Integrated Voltage Measurement... 16:37:10 Voltage Offset Correction: v_off_ini = 3018.902 uV, v_off_fin = 3002.815 uV 16:37:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.918 uVs 16:37:10 Integrated Voltage Measurement... 16:37:19 Voltage Offset Correction: v_off_ini = 3014.538 uV, v_off_fin = 3035.072 uV 16:37:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 158.938 uVs 16:37:19 Integrated Voltage Measurement... 16:37:28 Voltage Offset Correction: v_off_ini = 3010.235 uV, v_off_fin = 3003.452 uV 16:37:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.068 uVs 16:37:28 Integrated Voltage Measurement... 16:37:37 Voltage Offset Correction: v_off_ini = 3001.821 uV, v_off_fin = 3017.710 uV 16:37:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.760 uVs 16:37:37 Integrated Voltage Measurement... 16:37:46 Voltage Offset Correction: v_off_ini = 3000.836 uV, v_off_fin = 3018.372 uV 16:37:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -144.798 uVs 16:37:46 Integrated Voltage Measurement... 16:37:55 Voltage Offset Correction: v_off_ini = 2998.425 uV, v_off_fin = 2987.678 uV 16:37:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.935 uVs 16:37:57 I2Y Average and RMS of Measurements VT = -170.569 +- 9.845 uVs I2Y = -15.692 +- 0.906 uTm^2 16:38:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:16 Integrated Voltage Measurement... 16:38:25 Voltage Offset Correction: v_off_ini = 2970.167 uV, v_off_fin = 2979.560 uV 16:38:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.938 uVs 16:38:25 Integrated Voltage Measurement... 16:38:34 Voltage Offset Correction: v_off_ini = 3008.564 uV, v_off_fin = 2997.691 uV 16:38:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 86.236 uVs 16:38:34 Integrated Voltage Measurement... 16:38:43 Voltage Offset Correction: v_off_ini = 3019.055 uV, v_off_fin = 3038.231 uV 16:38:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.757 uVs 16:38:43 Integrated Voltage Measurement... 16:38:52 Voltage Offset Correction: v_off_ini = 3058.625 uV, v_off_fin = 3069.847 uV 16:38:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.699 uVs 16:38:52 Integrated Voltage Measurement... 16:39:01 Voltage Offset Correction: v_off_ini = 3043.632 uV, v_off_fin = 3018.123 uV 16:39:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.699 uVs 16:39:01 Integrated Voltage Measurement... 16:39:10 Voltage Offset Correction: v_off_ini = 3014.190 uV, v_off_fin = 3016.672 uV 16:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.089 uVs 16:39:14 I1X Average and RMS of Measurements VT = -101.570 +- 12.352 uVs I1X = 20.314 +- 2.470 uTm 16:39:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:21 Integrated Voltage Measurement... 16:39:30 Voltage Offset Correction: v_off_ini = 3052.576 uV, v_off_fin = 3036.645 uV 16:39:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -187.025 uVs 16:39:30 Integrated Voltage Measurement... 16:39:39 Voltage Offset Correction: v_off_ini = 3026.278 uV, v_off_fin = 3043.589 uV 16:39:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 193.973 uVs 16:39:39 Integrated Voltage Measurement... 16:39:48 Voltage Offset Correction: v_off_ini = 3051.898 uV, v_off_fin = 3050.337 uV 16:39:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.287 uVs 16:39:48 Integrated Voltage Measurement... 16:39:57 Voltage Offset Correction: v_off_ini = 3032.906 uV, v_off_fin = 3027.023 uV 16:39:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.752 uVs 16:39:57 Integrated Voltage Measurement... 16:40:06 Voltage Offset Correction: v_off_ini = 3067.431 uV, v_off_fin = 3066.263 uV 16:40:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.418 uVs 16:40:06 Integrated Voltage Measurement... 16:40:15 Voltage Offset Correction: v_off_ini = 3090.104 uV, v_off_fin = 3084.634 uV 16:40:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.590 uVs 16:40:19 I1Y Average and RMS of Measurements VT = -190.341 +- 5.927 uVs I1Y = -38.067 +- 1.185 uTm 16:40:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:27 Integrated Voltage Measurement... 16:40:36 Voltage Offset Correction: v_off_ini = 3050.300 uV, v_off_fin = 3044.043 uV 16:40:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.946 uVs 16:40:36 Integrated Voltage Measurement... 16:40:45 Voltage Offset Correction: v_off_ini = 3046.927 uV, v_off_fin = 3062.813 uV 16:40:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.647 uVs 16:40:45 Integrated Voltage Measurement... 16:40:54 Voltage Offset Correction: v_off_ini = 3029.488 uV, v_off_fin = 3042.094 uV 16:40:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.442 uVs 16:40:54 Integrated Voltage Measurement... 16:41:03 Voltage Offset Correction: v_off_ini = 3053.727 uV, v_off_fin = 3081.782 uV 16:41:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.484 uVs 16:41:03 Integrated Voltage Measurement... 16:41:12 Voltage Offset Correction: v_off_ini = 3069.528 uV, v_off_fin = 3048.010 uV 16:41:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.311 uVs 16:41:12 Integrated Voltage Measurement... 16:41:21 Voltage Offset Correction: v_off_ini = 3066.241 uV, v_off_fin = 3075.270 uV 16:41:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.604 uVs 16:41:23 I2X Average and RMS of Measurements VT = -81.906 +- 4.293 uVs I2X = 7.536 +- 0.395 uTm^2 16:41:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:31 Integrated Voltage Measurement... 16:41:40 Voltage Offset Correction: v_off_ini = 3066.122 uV, v_off_fin = 3077.069 uV 16:41:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.471 uVs 16:41:40 Integrated Voltage Measurement... 16:41:49 Voltage Offset Correction: v_off_ini = 3063.420 uV, v_off_fin = 3049.505 uV 16:41:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.633 uVs 16:41:49 Integrated Voltage Measurement... 16:41:58 Voltage Offset Correction: v_off_ini = 3038.252 uV, v_off_fin = 3064.776 uV 16:41:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.594 uVs 16:41:58 Integrated Voltage Measurement... 16:42:07 Voltage Offset Correction: v_off_ini = 3060.027 uV, v_off_fin = 3062.792 uV 16:42:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.164 uVs 16:42:07 Integrated Voltage Measurement... 16:42:16 Voltage Offset Correction: v_off_ini = 3054.595 uV, v_off_fin = 3055.630 uV 16:42:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.848 uVs 16:42:16 Integrated Voltage Measurement... 16:42:25 Voltage Offset Correction: v_off_ini = 3045.389 uV, v_off_fin = 3066.074 uV 16:42:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.490 uVs 16:42:27 I2Y Average and RMS of Measurements VT = -191.200 +- 2.853 uVs I2Y = -17.590 +- 0.262 uTm^2 16:42:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:46 Integrated Voltage Measurement... 16:42:55 Voltage Offset Correction: v_off_ini = 3063.148 uV, v_off_fin = 3060.934 uV 16:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.795 uVs 16:42:55 Integrated Voltage Measurement... 16:43:04 Voltage Offset Correction: v_off_ini = 3055.892 uV, v_off_fin = 3058.600 uV 16:43:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 64.080 uVs 16:43:04 Integrated Voltage Measurement... 16:43:13 Voltage Offset Correction: v_off_ini = 3048.984 uV, v_off_fin = 3071.129 uV 16:43:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.827 uVs 16:43:13 Integrated Voltage Measurement... 16:43:22 Voltage Offset Correction: v_off_ini = 3061.008 uV, v_off_fin = 3068.975 uV 16:43:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.414 uVs 16:43:22 Integrated Voltage Measurement... 16:43:31 Voltage Offset Correction: v_off_ini = 3055.421 uV, v_off_fin = 3033.996 uV 16:43:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.780 uVs 16:43:31 Integrated Voltage Measurement... 16:43:40 Voltage Offset Correction: v_off_ini = 3061.951 uV, v_off_fin = 3048.139 uV 16:43:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.847 uVs 16:43:44 I1X Average and RMS of Measurements VT = -88.124 +- 8.900 uVs I1X = 17.625 +- 1.780 uTm 16:43:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:51 Integrated Voltage Measurement... 16:44:00 Voltage Offset Correction: v_off_ini = 3084.547 uV, v_off_fin = 3053.065 uV 16:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -200.547 uVs 16:44:00 Integrated Voltage Measurement... 16:44:09 Voltage Offset Correction: v_off_ini = 3048.977 uV, v_off_fin = 3064.560 uV 16:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.802 uVs 16:44:09 Integrated Voltage Measurement... 16:44:18 Voltage Offset Correction: v_off_ini = 3061.025 uV, v_off_fin = 3072.191 uV 16:44:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.917 uVs 16:44:18 Integrated Voltage Measurement... 16:44:27 Voltage Offset Correction: v_off_ini = 3094.875 uV, v_off_fin = 3106.247 uV 16:44:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.184 uVs 16:44:27 Integrated Voltage Measurement... 16:44:36 Voltage Offset Correction: v_off_ini = 3086.330 uV, v_off_fin = 3113.645 uV 16:44:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.171 uVs 16:44:36 Integrated Voltage Measurement... 16:44:45 Voltage Offset Correction: v_off_ini = 3105.040 uV, v_off_fin = 3114.815 uV 16:44:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.222 uVs 16:44:49 I1Y Average and RMS of Measurements VT = -193.141 +- 5.951 uVs I1Y = -38.626 +- 1.190 uTm 16:44:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:57 Integrated Voltage Measurement... 16:45:05 Voltage Offset Correction: v_off_ini = 3093.915 uV, v_off_fin = 3092.710 uV 16:45:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -72.976 uVs 16:45:06 Integrated Voltage Measurement... 16:45:15 Voltage Offset Correction: v_off_ini = 3094.034 uV, v_off_fin = 3083.267 uV 16:45:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.983 uVs 16:45:15 Integrated Voltage Measurement... 16:45:24 Voltage Offset Correction: v_off_ini = 3099.320 uV, v_off_fin = 3085.888 uV 16:45:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.972 uVs 16:45:24 Integrated Voltage Measurement... 16:45:33 Voltage Offset Correction: v_off_ini = 3110.392 uV, v_off_fin = 3124.945 uV 16:45:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.148 uVs 16:45:33 Integrated Voltage Measurement... 16:45:42 Voltage Offset Correction: v_off_ini = 3124.644 uV, v_off_fin = 3127.726 uV 16:45:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.986 uVs 16:45:42 Integrated Voltage Measurement... 16:45:51 Voltage Offset Correction: v_off_ini = 3128.760 uV, v_off_fin = 3164.956 uV 16:45:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.033 uVs 16:45:53 I2X Average and RMS of Measurements VT = -82.849 +- 10.054 uVs I2X = 7.622 +- 0.925 uTm^2 16:45:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:01 Integrated Voltage Measurement... 16:46:10 Voltage Offset Correction: v_off_ini = 3147.941 uV, v_off_fin = 3145.221 uV 16:46:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.111 uVs 16:46:10 Integrated Voltage Measurement... 16:46:19 Voltage Offset Correction: v_off_ini = 3148.023 uV, v_off_fin = 3148.357 uV 16:46:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.855 uVs 16:46:19 Integrated Voltage Measurement... 16:46:28 Voltage Offset Correction: v_off_ini = 3149.480 uV, v_off_fin = 3147.500 uV 16:46:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.332 uVs 16:46:28 Integrated Voltage Measurement... 16:46:37 Voltage Offset Correction: v_off_ini = 3147.362 uV, v_off_fin = 3141.487 uV 16:46:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.027 uVs 16:46:37 Integrated Voltage Measurement... 16:46:46 Voltage Offset Correction: v_off_ini = 3136.250 uV, v_off_fin = 3116.991 uV 16:46:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.200 uVs 16:46:46 Integrated Voltage Measurement... 16:46:55 Voltage Offset Correction: v_off_ini = 3128.732 uV, v_off_fin = 3128.517 uV 16:46:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.386 uVs 16:46:57 I2Y Average and RMS of Measurements VT = -184.485 +- 13.220 uVs I2Y = -16.973 +- 1.216 uTm^2 16:47:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:16 Integrated Voltage Measurement... 16:47:25 Voltage Offset Correction: v_off_ini = 3123.158 uV, v_off_fin = 3116.730 uV 16:47:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.269 uVs 16:47:25 Integrated Voltage Measurement... 16:47:34 Voltage Offset Correction: v_off_ini = 3133.330 uV, v_off_fin = 3140.128 uV 16:47:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.293 uVs 16:47:34 Integrated Voltage Measurement... 16:47:43 Voltage Offset Correction: v_off_ini = 3128.949 uV, v_off_fin = 3144.494 uV 16:47:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.663 uVs 16:47:43 Integrated Voltage Measurement... 16:47:52 Voltage Offset Correction: v_off_ini = 3134.416 uV, v_off_fin = 3142.391 uV 16:47:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.799 uVs 16:47:52 Integrated Voltage Measurement... 16:48:01 Voltage Offset Correction: v_off_ini = 3148.803 uV, v_off_fin = 3120.809 uV 16:48:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.047 uVs 16:48:01 Integrated Voltage Measurement... 16:48:10 Voltage Offset Correction: v_off_ini = 3118.208 uV, v_off_fin = 3147.513 uV 16:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.008 uVs 16:48:14 I1X Average and RMS of Measurements VT = -89.013 +- 12.816 uVs I1X = 17.803 +- 2.563 uTm 16:48:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:21 Integrated Voltage Measurement... 16:48:30 Voltage Offset Correction: v_off_ini = 3121.996 uV, v_off_fin = 3114.631 uV 16:48:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -201.629 uVs 16:48:30 Integrated Voltage Measurement... 16:48:39 Voltage Offset Correction: v_off_ini = 3112.632 uV, v_off_fin = 3106.251 uV 16:48:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.218 uVs 16:48:39 Integrated Voltage Measurement... 16:48:48 Voltage Offset Correction: v_off_ini = 3110.529 uV, v_off_fin = 3121.020 uV 16:48:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.621 uVs 16:48:48 Integrated Voltage Measurement... 16:48:57 Voltage Offset Correction: v_off_ini = 3113.859 uV, v_off_fin = 3107.992 uV 16:48:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.824 uVs 16:48:57 Integrated Voltage Measurement... 16:49:06 Voltage Offset Correction: v_off_ini = 3106.607 uV, v_off_fin = 3108.637 uV 16:49:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.522 uVs 16:49:06 Integrated Voltage Measurement... 16:49:15 Voltage Offset Correction: v_off_ini = 3116.800 uV, v_off_fin = 3127.117 uV 16:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.412 uVs 16:49:19 I1Y Average and RMS of Measurements VT = -189.037 +- 7.183 uVs I1Y = -37.808 +- 1.437 uTm 16:49:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:49:26 Integrated Voltage Measurement... 16:49:35 Voltage Offset Correction: v_off_ini = 3098.225 uV, v_off_fin = 3091.850 uV 16:49:35 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -90.100 uVs 16:49:35 Integrated Voltage Measurement... 16:49:44 Voltage Offset Correction: v_off_ini = 3094.151 uV, v_off_fin = 3100.825 uV 16:49:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.430 uVs 16:49:45 Integrated Voltage Measurement... 16:49:53 Voltage Offset Correction: v_off_ini = 3095.307 uV, v_off_fin = 3081.017 uV 16:49:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.665 uVs 16:49:54 Integrated Voltage Measurement... 16:50:03 Voltage Offset Correction: v_off_ini = 3101.797 uV, v_off_fin = 3088.736 uV 16:50:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.028 uVs 16:50:03 Integrated Voltage Measurement... 16:50:12 Voltage Offset Correction: v_off_ini = 3074.778 uV, v_off_fin = 3069.218 uV 16:50:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.578 uVs 16:50:12 Integrated Voltage Measurement... 16:50:21 Voltage Offset Correction: v_off_ini = 3083.721 uV, v_off_fin = 3093.393 uV 16:50:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.695 uVs 16:50:23 I2X Average and RMS of Measurements VT = -74.750 +- 3.156 uVs I2X = 6.877 +- 0.290 uTm^2 16:50:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:31 Integrated Voltage Measurement... 16:50:40 Voltage Offset Correction: v_off_ini = 3069.961 uV, v_off_fin = 3059.807 uV 16:50:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -184.414 uVs 16:50:40 Integrated Voltage Measurement... 16:50:49 Voltage Offset Correction: v_off_ini = 3087.415 uV, v_off_fin = 3083.243 uV 16:50:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.534 uVs 16:50:49 Integrated Voltage Measurement... 16:50:58 Voltage Offset Correction: v_off_ini = 3072.809 uV, v_off_fin = 3088.286 uV 16:50:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.139 uVs 16:50:58 Integrated Voltage Measurement... 16:51:07 Voltage Offset Correction: v_off_ini = 3091.549 uV, v_off_fin = 3107.802 uV 16:51:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.971 uVs 16:51:07 Integrated Voltage Measurement... 16:51:16 Voltage Offset Correction: v_off_ini = 3105.425 uV, v_off_fin = 3104.465 uV 16:51:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.553 uVs 16:51:16 Integrated Voltage Measurement... 16:51:25 Voltage Offset Correction: v_off_ini = 3099.931 uV, v_off_fin = 3119.548 uV 16:51:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.594 uVs 16:51:27 I2Y Average and RMS of Measurements VT = -181.534 +- 8.259 uVs I2Y = -16.701 +- 0.760 uTm^2 16:51:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:46 Integrated Voltage Measurement... 16:51:55 Voltage Offset Correction: v_off_ini = 3115.178 uV, v_off_fin = 3097.909 uV 16:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.321 uVs 16:51:55 Integrated Voltage Measurement... 16:52:04 Voltage Offset Correction: v_off_ini = 3089.819 uV, v_off_fin = 3122.291 uV 16:52:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.897 uVs 16:52:04 Integrated Voltage Measurement... 16:52:13 Voltage Offset Correction: v_off_ini = 3122.755 uV, v_off_fin = 3121.875 uV 16:52:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.192 uVs 16:52:13 Integrated Voltage Measurement... 16:52:22 Voltage Offset Correction: v_off_ini = 3135.690 uV, v_off_fin = 3120.532 uV 16:52:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.312 uVs 16:52:22 Integrated Voltage Measurement... 16:52:31 Voltage Offset Correction: v_off_ini = 3100.988 uV, v_off_fin = 3094.753 uV 16:52:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.615 uVs 16:52:31 Integrated Voltage Measurement... 16:52:40 Voltage Offset Correction: v_off_ini = 3108.915 uV, v_off_fin = 3102.339 uV 16:52:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.359 uVs 16:52:44 I1X Average and RMS of Measurements VT = -62.116 +- 11.883 uVs I1X = 12.423 +- 2.377 uTm 16:52:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:51 Integrated Voltage Measurement... 16:53:00 Voltage Offset Correction: v_off_ini = 3100.047 uV, v_off_fin = 3106.256 uV 16:53:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -205.094 uVs 16:53:00 Integrated Voltage Measurement... 16:53:09 Voltage Offset Correction: v_off_ini = 3113.374 uV, v_off_fin = 3139.696 uV 16:53:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.596 uVs 16:53:09 Integrated Voltage Measurement... 16:53:18 Voltage Offset Correction: v_off_ini = 3125.979 uV, v_off_fin = 3122.818 uV 16:53:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.362 uVs 16:53:18 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = 3125.852 uV, v_off_fin = 3135.813 uV 16:53:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.748 uVs 16:53:27 Integrated Voltage Measurement... 16:53:36 Voltage Offset Correction: v_off_ini = 3118.613 uV, v_off_fin = 3109.006 uV 16:53:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -202.167 uVs 16:53:36 Integrated Voltage Measurement... 16:53:44 Voltage Offset Correction: v_off_ini = 3117.494 uV, v_off_fin = 3136.596 uV 16:53:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.275 uVs 16:53:49 I1Y Average and RMS of Measurements VT = -199.874 +- 3.237 uVs I1Y = -39.972 +- 0.646 uTm 16:53:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:56 Integrated Voltage Measurement... 16:54:05 Voltage Offset Correction: v_off_ini = 3107.325 uV, v_off_fin = 3107.292 uV 16:54:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.047 uVs 16:54:05 Integrated Voltage Measurement... 16:54:14 Voltage Offset Correction: v_off_ini = 3089.282 uV, v_off_fin = 3120.710 uV 16:54:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 31.160 uVs 16:54:14 Integrated Voltage Measurement... 16:54:23 Voltage Offset Correction: v_off_ini = 3110.776 uV, v_off_fin = 3105.271 uV 16:54:23 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -67.037 uVs 16:54:23 Integrated Voltage Measurement... 16:54:32 Voltage Offset Correction: v_off_ini = 3129.341 uV, v_off_fin = 3101.123 uV 16:54:32 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 61.545 uVs 16:54:33 Integrated Voltage Measurement... 16:54:41 Voltage Offset Correction: v_off_ini = 3085.950 uV, v_off_fin = 3055.883 uV 16:54:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.775 uVs 16:54:42 Integrated Voltage Measurement... 16:54:50 Voltage Offset Correction: v_off_ini = 3104.884 uV, v_off_fin = 3103.537 uV 16:54:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 61.458 uVs 16:54:53 I2X Average and RMS of Measurements VT = -57.337 +- 11.888 uVs I2X = 5.276 +- 1.094 uTm^2 16:54:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:01 Integrated Voltage Measurement... 16:55:10 Voltage Offset Correction: v_off_ini = 3101.144 uV, v_off_fin = 3106.832 uV 16:55:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.557 uVs 16:55:10 Integrated Voltage Measurement... 16:55:19 Voltage Offset Correction: v_off_ini = 3085.657 uV, v_off_fin = 3108.283 uV 16:55:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 201.357 uVs 16:55:19 Integrated Voltage Measurement... 16:55:28 Voltage Offset Correction: v_off_ini = 3102.166 uV, v_off_fin = 3099.829 uV 16:55:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.949 uVs 16:55:28 Integrated Voltage Measurement... 16:55:37 Voltage Offset Correction: v_off_ini = 3092.353 uV, v_off_fin = 3083.604 uV 16:55:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.252 uVs 16:55:37 Integrated Voltage Measurement... 16:55:46 Voltage Offset Correction: v_off_ini = 3097.792 uV, v_off_fin = 3058.905 uV 16:55:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.355 uVs 16:55:46 Integrated Voltage Measurement... 16:55:55 Voltage Offset Correction: v_off_ini = 3058.516 uV, v_off_fin = 3053.397 uV 16:55:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.374 uVs 16:55:57 I2Y Average and RMS of Measurements VT = -202.307 +- 5.605 uVs I2Y = -18.613 +- 0.515 uTm^2 16:56:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm